2012catalogue product - realcold us 0800 11 66 90 dear customer, welcome to the realcold 2012...

267
Product Catalogue 2012 People Product Partnerships

Upload: phamnga

Post on 28-May-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

Product Catalogue2012

Peop

le

Prod

uct

Partn

ersh

ips

Call us 0800 11 66 90www.realcold.co.nz

Dear Customer,

Welcome to the Realcold 2012 Product Catalogue. We trust you will find it a quick and easy to use reference tool. To make it even easier for you to navigate, the 2012 Catalogue includes a brand and product index, located at the back of the Catalogue.

Please give us a call if you require any additional product information or need our technical expertise. We look forward to working together in 2012.

Yours faithfully,

The Realcold Team

Air

Con

ditio

ning

Com

pone

nts

Cap

ital P

lant

Tech

nica

l Dat

aIn

dust

rial

Air ConditioningMitsubishi Heavy Industries and Gree Electric Air Conditioners and Heatpumps, Toyo Pair Coil and Trunking, PVC Drainpipe and Fittings, Aspen Condensate Pumps, Ducting and Grills, etc.

ComponentsCompressors, Controls, Driers, Fans, Insulation, Lubricants, Copper Tube and Fittings, Refrigerants, Test Equipment, Tools, Thermostats, Refrigeration, etc.

IndustrialIndustrial Refrigeration Valves, Pumps, Controls. Hansen Valves, Purgers, Level Controls, Lederle Hermetic Refrigerant Pumps, Spares, Parts Kits, etc.

Page

3Page

55Page

169

Technical Data & IndexCapacity Tables, Refrigeration Terminology, Technical Tips, Guide to Calculating Noise Levels, Metric Conversion Chart, Pressure - Temperature Data, Properties Of Refrigerants, etc.

Page

225

Product Sections

Capital PlantL’Unite Condensing Units, EasyPacks, RealPacks, Copeland Scroll Condensing Units, Custom Build, Condensors, Evaporators, Ice Machines, Chilled Water Packages, etc.

Page

195

Air

Conditioning

Air

Con

ditio

ning

Air ConditioningMitsubishi Heavy Industries - Heat Pumps AC04

DXK High-Wall Split Systems AC04SRK High-Wall Split Systems High EER / COP AC05SRF Floor Mounted Split Systems AC06SCM Multi Inverter Split System AC07Cassette Split Systems AC08Ducted Split Systems - Medium & High Static AC09UNDER CEILING SPLIT SYSTEMS, ACCESSORIES AC10

Gree Electric - Heat Pumps AC11Gree Eco Window-Wall Series AC11Gree Cozy High-Wall Split Systems AC12Gree Cozy High-Wall Inverter Split Systems AC13Gree Multi Head Systems AC14Gree Multi Head Systems AC15Energy Recovery Ventilation AC16

Eclipse Air Curtains AC17

Cool Breeze Evaporative Air Conditioning AC18Down Discharge Model AC20Top Discharge Model AC21Side Discharge Model AC21Mobile Model AC22Accessories AC23Evaporative Cooling AC24

Air Conditioning Accessories AC27Mounting Brackets & Bases AC27Pre-Insulated Copper Tube AC28Ducting AC29Condensate Drain Pipe & Fittings AC30

Condensate Pumps AC32Hi Lift Pumps AC32Hi Flow Pumps AC32Universal Pump AC33Supermarket Pump AC33AC-Tabs AC33Compact Pumps - Hidden Installation AC34Compact Pumps - Below Wall Unit Installation AC35Spares For Pumps AC35

Heat Pump Accessories AC35

Electrical & Thermostats AC36Components & Fittings AC36Seitron Air Conditioning Thermostats AC36

4 Way Valves AC37Saginomiya 4-Way Reversing Valve AC37

Ducting Accessories AC38Flexible Ducting AC38Duct Fittings AC39Diffuser AC40Neck Adapter AC42Eggcrate Grille AC43Wall / Ceiling Fans / Grills AC44Roof Ventilation AC45In Line Fans AC46Transfer Fans AC50

Air Conditioning Warranty Information AC51

AC04

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DXK HIGH-WALL SPLIT SYSTEMS

Reverse Cycle Inverter High Wall - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3001-I/O DXK09Z3-S DXC09Z3-S

R410a 2.5 (1.0~2.7) 36~30~22 8,5 230/1/50 1,250.00

3.2 (1.2~4.2) 56 32

AC3002-I/O DXK12Z3-S DXC12Z3-S

R410a 3.5 (1.0~3.7) 39~32~23 8,5 230/1/50 1,500.00

4.0 (1.3~4.8) 59 35

AC3003-I/O DXK18Z3-S DXC18Z3-S

R410a 5.0 (1.6~5.5) 47~37~26 8,5 230/1/50 1,950.00

5.8 (1.6~6.6) 61 42

AC3004-I/O DXK21Z4-S DXC21Z4-S

R410a 6.3 (2.15~7.1) 44~41~36~33 15 230/1/50 2,400.00

7.1 (1.7~9.5) 62 57

AC3005-I/O DXK24Z4-S DXC24Z4-S

R410a 7.1 (2.15~8.0) 46~43~39~35 15 230/1/50 2,600.00

8.0 (1.6~10.0) 64 57

AC3006-I/O DXK28Z4-S DXC28Z4-S

R410a 8.0 (2.15~8.5) 48~45~40~37 15 230/1/50 3,000.00

9.0 (1.7~10.5) 66 57

Specifications - High-Wall Reverse Cycle - DXKDXK High Wall Series DXK09Z3-S

DXC09Z3-SDXK12Z3-SDXC12Z3-S

DXK18Z3-SDXC18Z3-S

DXK21Z4-S DXC21Z4-S

DXK24Z4-S DXC24Z4-S

DXK28Z4-S DXC28Z4-S

Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 2.5 (1.0~2.7) 3.5 (1.0~3.7) 5.0 (1.6~5.5) 6.3 (2.15~7.1) 7.1 (2.15~8.0) 8.0 (2.15~8.5)

Heating H1 3.2 (1.2~4.2) 4.0 (1.3~4.8) 5.8 (1.6~6.6) 7.1 (1.7~9.5) 8.0 (1.6~10.0) 9.0 (1.7~10.5)Input Cooling T1 kW 0.71 1.06 1.56 1.76 2.16 2.65

Heating H1 0.86 1.09 1.6 1.79 2.14 2.55Energy Label 2011 Cooling Stars 2 1.5 1.5 2.0 1.5 1.0

Heating 3 2.5 2 2.77 2.5 2.0AEER Cooling T1 3.52 3.3 3.21 3.58 3.29 3.02ACOP Heating H1 3.72 3.67 3.63 3.97 3.74 3.53Current Cooling T1 Amp 3.4 4.9 6.9 8 9.7 11.9

Heating H1 4 5 7 8.1 9.7 11.4

Recommended Circuit Breaker Amp 16 20Sound Pressure Level (JIS C9612)

Cool Ind dB 36~30~22 39~32~23 47~37~26 47~43~37~26 49~45~39~26 50~47~41~26Heat Ind 35~30~26 41~36~27 47~40~33 44~41~36~33 46~43~39~35 48~45~40~37

Sound Power Level (JIS C9612)

Outdoor dBA 56 59 61 62 66 69

Airflow Indoor L/S 133~103~75 141~113~76 183~126~78 310 325 350External Dimensions (H x W x D)

Indoor mm 268 x 790 x 224 318 x 1098 x 248Outdoor 540 x 780 (+62) x 290 640 x 800 (+71) x 290 750 x 880 (+88) x 340

Nett Weight Indoor Kg 8.5 15Outdoor 32 35 42 57

Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8") 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 0.75 1.05 1.35 1.8m 10 15

Max. Piping Length Overall/Height m 15 / 10 25 / 15 30 / 20

Features & Benefits

• New DXK**Z4 Series to meet Australian MEPS IV

• DXK21-24-28 replace the SRK**ZEA series

• Jet Air scroll, long reach and silent airflow

• 24 hour programmable function, Auto restart function

• Self clean operation

• Micro computer operated defrosting

• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52

Mitsubishi Heavy Industries - Heat Pumps

DXK High-Wall Split Systems

AC05

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

SRK HIGH-WALL SPLIT SYSTEMS HIGH EER / COP

Reverse Cycle Inverter High Wall - R410a High EER/COPRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3101-I/O SRK20ZJX-S SRC20ZJX-S

R410a 2.0 (0.9~3.1) 39~30~21 15 230/1/50 1,350.00

2.5 (0.9~4.3) 60 38

AC3102-I/O SRK25ZJX-S SRC25ZJX-S

R410a 2.55 (0.9~3.2) 41~31~22 15 230/1/50 1,650.00

3.13 (0.9~4.7) 60 38

AC3103-I/O SRK35ZJX-S SRC35ZJX-S

R410a 3.5 (0.9~4.1) 43~33~22 15 230/1/50 1,850.00

4.3 (0.9~5.1) 63 38

AC3104-I/O SRK50ZJX-S SRC50ZJX-S

R410a 5.0 (0.7~6.2) 47~40~27 15 230/1/50 2,250.00

6.0 (0.7~8.8) 62 43

AC3105-I/O SRK60ZJX-S SRC60ZJX-S

R410a 6.0 (0.8~6.8) 51~41~29 15 230/1/50 2,350.00

6.8 (0.8~9.7) 65 43

Features & Benefits

• High COP / EER

• Alergen Clear & Photocatalytic filters

• 24 hour programmable function

• Auto restart function

• Micro computer operated defrosting

• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52

Specifications - High-Wall Reverse Cycle - SRKSRK-ZJX High Wall Series SRK20ZJX-S

SRC20ZJX-SSRK25ZJX-SSRC25ZJX-S

SRK35ZJX-SSRC35ZJX-S

SRK50ZJX-SSRC50ZJX-S

SRK60ZJX-SSRC60ZJX-S

Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.0 (09~3.1) 2.55 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (0.7~6.2) 6.0 (0.8~6.8)

Heating H1 2.5 (0.9~4.3) 3.13 (0.9~4.7) 4.3 (0.9~5.1) 6.0 (0.7~8.8) 6.8 (0.8~9.7)Input Cooling T1 kW 0.35 0.49 0.845 1.3 1.86

Heating H1 0.45 0.595 0.96 1.35 1.67Energy Label 2011 Cooling Stars 6 5 3 2.5 1.5

Heating 5.5 5.5 3.5 3.5 3AEER Cooling T1 5.71 5.2 4.14 3.85 3.23ACOP Heating H1 5.56 5.26 4.48 4.44 4.07Current Cooling T1 Amp 1.8 2.4 3.8 5.7 8.2

Heating H1 2.3 2.9 4.4 5.9 7.3

Recommended Circuit Breaker Amp 16Sound Pressure Level (JIS C9612)

Cool Ind dB 39~30~21 41~31~22 43~33~22 47~40~27 51~41~29Heat Ind 38~33~25 41~34~27 42~35~27 48~40~33 48~41~34

Sound Power Level (JIS C9612)

Outdoor dBA 60 60 63 62 65

Airflow Indoor L/S 191~133~83 208~150~83 225~158~83 225~183~133 241~208~141External Dimensions (H x W x D)

Indoor mm 309 x 890 x 220Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290

Nett Weight Indoor Kg 15Outdoor 38 43

Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8”) 12.7 (1/2”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 1.2 1.4m Pre-charged for 15m of field piping

Max. Piping Length Overall/Height m 15 / 10 30 / 20

SRK High-Wall Split Systems High EER / COP

AC06

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

SRF FLOOR MOUNTED SPLIT SYSTEMS

Reverse Cycle Inverter Floor Mounted - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3201-I/O SRF25ZJX-S SRC25ZJX-S

R410a 2.5 (0.9~3.2) 38~31~26 18 230/1/50 2,200.00

3.4 (0.9~4.7) 60 38

AC3202-I/O SRF35ZJX-S SRC35ZJX-S

R410a 3.5 (0.9~4.1) 41~34~28 19 230/1/50 2,500.00

4.5 (0.9~5.1) 63 38

AC3203-I/O SRF50ZJX-S SRC50ZIX-S

R410a 5.0 (0.7~5.5) 46~42~32 19 230/1/50 2,800.00

6.0 (0.7~7.0) 62 43

Features & Benefits

• Hi Power

• Enzyme & Photocatalytic filters

• 24 hour programmable function

• Upper and Lower air outlet selection

• Micro computer operated defrosting

• Auto restart

• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52

Specifications - Reverse Cycle Floor Mounted - SRFSRF Floor Mounted Series SRF25ZJX-S

SRC25ZJX-SSRF35ZJX-SSRC35ZJX-S

SRF50ZJX-SSRC50ZI X-S

Power Supply Outdoor Unit 1 phase 230V 50Hz

Capacity Cooling T1 kW 2.5 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (0.7~5.5)

Heating H1 3.4 (0.9~4.7) 4.5 (0.9~5.1) 6.0 (0.7~7.0)

Input Cooling T1 kW 0.521 0.89 1.39

Heating H1 0.723 1.124 1.54

Energy Label 2011 Cooling Stars 4 2.5 2

Heating 4 3 2.5

AEER Cooling T1 4.8 3.93 3.6

ACOP Heating H1 4.7 4 3.9

Current Cooling T1 Amp 2.5 3.9 6.1

Heating H1 3.4 4.9 6.8

Recommended Circuit Breaker Amp 16

Sound Pressure Level (JIS C9612)

Cool Ind dB 38~31~26 41~34~28 46~42~32

Heat Ind 38~34~28 41~36~31 47~41~33

Sound Power Level (JIS C9612)

Outdoor dBA 60 63 62

Airflow Indoor L/S 150~126~96 153~130~106 191~160~110

External Dimensions (H x W x D)

Indoor mm 600 x 860 x 238

Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290

Nett Weight Indoor Kg 18 19

Outdoor 38 43

Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)

Gas Line 9.52 (3/8”) 12.7 (1/2”)

Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 1.2 1.4

m Pre-charged for 15m of field piping

Max. Piping Length Overall/Height m 15 / 10 30 / 20

SRF Floor Mounted Split Systems

AC07

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

SCM MULTI INVERTER SPLIT SYSTEM

Reverse Cycle Inverter Outdoor Units - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

No of Rooms Max kW Cooling Connect

Largest Indoor Connect

ElectricSupply

System Price$ Excl. GST

AC3301 SCM40ZJ-S R410a 4.0 (1.8~5.9) 2 rooms 6.0kW 3.5kW 230/1/50 2,300.00

4.5 (1.4~6.9)

AC3302 SCM50ZJ-S R410a 5.0 (1.8~7.1) 2~3 rooms 8.5kW 5.0kW 230/1/50 2,750.00

6.0 (1.4~7.5)

AC3303 SCM60ZJ-S R410a 6.0 (1.8~7.5) 2~3 rooms 11.0kW 6.0kW 230/1/50 3,000.00

6.8 (1.5~7.8)

AC3304 SCM71ZJ-S R410a 7.1 (1.8~8.8) 2~4 rooms 12.5kW 6.0kW 230/1/50 3,500.00

8.6 (1.5~9.4)

AC3305 SCM80ZJ-S R410a 8.0 (1.8~9.2) 2~4 rooms 13.5kW 6.0kW 230/1/50 3,850.00

9.3 (1.5~9.8)

Multi Indoor Units - Wall MountRealcoldStock No.

MitsubishiModel No.

Refrigerant Nominal Cap kW Cool / Heat

DimensionsH x W x D

Airflow Max L/S

Ind Sound dBA

ElectricSupply

System Price$ Excl. GST

AC3311 SRK20ZJ R410a 2.0/2.7 294 x 798 x 229 130 33/27/21 230/1/50 400.00

AC3312 SRK25ZJ R410a 2.5/3.2 295 x 798 x 229 131 34/28/21 230/1/50 432.00

AC3313 SRK35ZJ R410a 3.5/4.0 296 x 798 x 229 168 42/32/22 230/1/50 496.00

AC3314 SRK50ZJ R410a 5.0/5.8 297 x 798 x 229 188 46/37/26 230/1/50 640.00

AC3321 SRK20ZJX R410a 2.0/2.5 309 x 890 x 220 191 39/30/21 230/1/50 432.00

AC3322 SRK25ZJX R410a 2.5/3.1 309 x 890 x 220 208 41/31/22 230/1/50 528.00

AC3323 SRK35ZJX R410a 3.5/4.5 309 x 890 x 220 225 43/33/22 230/1/50 592.00

AC3324 SRK50ZJX R410a 5.0/5.8 309 x 890 x 220 225 47/40/27 230/1/50 720.00

AC3325 SRK60ZJX R410a 6.0/6.8 309 x 890 x 220 241 51/41/29 230/1/50 752.00

Multi Indoor Units - CassetteRealcoldStock No.

MitsubishiModel No.

Refrigerant Nominal Cap kW Cool / Heat

DimensionsH x W x D

Airflow Max L/S

Ind Sound dBA

ElectricSupply

System Price$ Excl. GST

AC3331 FDTC25Z R410a 2.5/3.4 248 x 570 x 570 150 36/32/29 230/1/50 POA

AC3332 FDTC35Z R410a 3.5/4.5 248 x 570 x 570 158 40/36/30 230/1/50 POA

AC3333 FDTC50Z R410a 5.0/5.8 248 x 570 x 570 192 42/36/30 230/1/50 POA

AC3334 FDTC60Z R410a 6.0/6.8 248 x 570 x 570 225 46/39/30 230/1/50 POA

Multi Indoor Units - Bulk Head (low static)RealcoldStock No.

MitsubishiModel No.

Refrigerant Nominal Cap kW Cool / Heat

DimensionsH x W x D

Airflow Max L/S

Ind Sound dBA

ElectricSupply

System Price$ Excl. GST

AC3341 SRR25ZJ R410a 2.5/3.4 230 x 740 x 455 142 40/35/29 230/1/50 900.00

AC3342 SRR35ZJ R410a 3.5/4.5 230 x 740 x 455 150 42/37/30 230/1/50 1,000.00

AC3343 SRR50ZJ R410a 5.0/5.8 230 x 740 x 455 175 48/42/33 230/1/50 1,150.00

AC3344 SRR60ZJ R410a 6.0/6.8 230 x 740 x 455 208 51/44/35 230/1/50 1,250.00

Multi Indoor Units - Floor MountRealcoldStock No.

MitsubishiModel No.

Refrigerant Nominal Cap kW Cool / Heat

DimensionsH x W x D

Airflow Max L/S

Ind Sound dBA

ElectricSupply

System Price$ Excl. GST

AC3351 SRF25ZJX R410a 2.5/3.4 600 x 860 x 238 150 40/32/26 230/1/50 1,078.00

AC3352 SRF35ZJX R410a 3.5/4.5 600 x 860 x 238 153 41/34/28 230/1/50 1,242.00

AC3353 SRF50ZJX R410a 5.0/5.8 600 x 860 x 238 191 46/42/32 230/1/50 1,270.00

SCM Multi Inverter Split System

AC08

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

CASSETTE SPLIT SYSTEMS

Reverse Cycle Inverter Cassette - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3401 FDTC50ZIXVD R410a 5.0 (2.2~5.6) 47~42~36~32 18.5 230/1/50 3,500.00

5.4 (2.5~6.3) 47 43

AC3402 FDT60ZIXVD R410a 5.6 (2.8~6.3) 46~33~31~30 29.5 230/1/50 3,750.00

6.7 (3.1~7.1) 48 43

AC3403 FDT71VNXVD R410a 7.1 (3.2~8.0) 46~35~33~31 29.5 230/1/50 4,750.00

8.0 (3.6~9.0) 51 60

AC3404 FDT100VNVD R410a 10.0 (4.0~11.2) 51~40~37~35 32.5 230/1/50 5,850.00

11.2 (4.0~12.5) 49 81

AC3405 FDT125VNXVD R410a 12.5 (5.0~14.0) 51~42~40~37 32.5 230/1/50 6,500.00

14.0 (4.0~17.0) 50 105

AC3406 FDT140VNXVD R410a 14.0 (5.0~16.0) 51~43~41~38 32.5 230/1/50 6,950.00

16.0 (4.0~18.0) 52 105

Note: Available in both wired control and Infra Red Control. Please specify Wired or Infra Red Control at time of order. Wired Control = RC-E4; Infra Red Control = RCN-T-36W-E

Features & Benefits

• Individual flap control

• Thin design, High efficiency

• Available in both Wired Control and Infra Red Control. Please specify Wired or Infra Red Control at time of order

• Wired Control; All RC-E4, Infra Red Control; FDT60, FDT140, RCN-T-36W-E & FDTC50, RCN-TC-24W-E

• CnT terminal to allow easy connection to BMS, home automation and external timers

Specifications - Reverse Cycle Inverter CassetteFDTC & FDT Cassette Series FDTC50ZIXVD

SRC50ZIX-S FDTC50VD

FDT60ZIXVDSRC60ZIX-S FDT60VD

FDT71VNXVDFDT71VNX FDT71VD

FDT100VNVDFDT100VN FDT100VD

FDT125VNXVDFDT125VNX FDT125VD

FDT140VNXVDFDT140VNX FDT140VD

Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)

Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 1.56 1.57 2.04 2.76 3.28 4.19

Heating H1 1.45 1.85 1.94 2.74 3.43 4.20Energy Label 2011 Cooling Stars 2 2.5 1.5 1.5 2.0 1.5

Heating 2.5 2.5 3.0 3.0 3.0 2.5AEER Cooling T1 3.21 3.57 3.48 3.62 3.81 3.34ACOP Heating H1 3.72 3.62 4.12 4.08 4.08 3.81Current Cooling T1 Amp 6.9 7.0 9.1 12.1 14.6 18.6

Heating H1 6.4 8.2 8.7 12.0 15.2 18.6

Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)

Cool Ind dB 47~42~36~32 46~33~31~30 46~35~33~31 51~40~37~35 51~42~40~37 51~43~41~38Heat Ind 47 48 51 49 50 52

Sound Power Level (JIS C9612)

Outdoor dBA 62 65 66 70 70 72

Airflow Indoor L/S 225~191~150~133 466~300~266~233 466~350~316~283 616~450~400~333 616~500~450~383 616~500~450~383

Panel T-PSA-3AW-E mm 35 x 700 x 700 35 x 950 x 950External Dimensions (H x W x D)

Indoor mm 248 x 570 x 570 246 x 840 x 840 298 x 840 x 840Outdoor 640 x 872 x 290 750 x 880 x 340 845 x 970 x 410 1300 x 970 x 370

Nett Weight Indoor Kg 18.5 29.5 32.5Outdoor 43 60 81 105

Refrigerant Piping Liquid Line mm (in)

6.35 (1/4”) 9.52 (3/8”)Gas Line 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 1.4 2.95 3.8 4.5m 15 30

Max. Piping Length Overall/Height m 30/20 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-TC-24W-ER or RCN-T-36W-E

Cassette Split Systems

AC09

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DUCTED SPLIT SYSTEMS - MEDIUM & HIGH STATIC

Reverse Cycle Inverter Ducted - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3601 FDUM50ZIXVD R410a 5.0 (2.2~5.6) 35~34~31~28 34 230/1/50 2,850.00

5.4 (2.5~6.3) 47 43

AC3602 FDUM60ZIXVD R410a 5.6 (2.8~6.3) 38~34~31~28 40 230/1/50 3,200.00

6.7 (3.1~7.1) 48 43

AC3603 FDU71VNXVD R410a 7.1 (3.2~8.0) 41~37 40 230/1/50 4,250.00

8.0 (3.6~9.0) 51 60

AC3604 FDU100VNVD R410a 10.0 (4.0~11.2) 42~37 63 230/1/50 4,900.00

11.2 (4.0~12.5) 49 81

AC3605 FDU125VNXVD R410a 12.5 (5.0~14.0) 43~38 63 230/1/50 5,600.00

14.0 (4.0~17.0) 50 105

AC3606 FDU140VNXVD R410a 14.0 (5.0~16.0) 43~38 63 230/1/50 6,800.00

16.0 (4.0~18.0) 52 105

Features & Benefits

• Quiet, lightweight and compact

• Selectable static pressure, 600 mm drain pump fitted

• Available in both wired control and Infra Red Control. Please specify Wired or Infra Red Control at time of order

• Wired Control, RC-E4. Infra Red Control, RCN-Kit3-E

• CnT terminal to allow easy connection to BMS, home automation and external timers

Specifications - Reverse Cycle Inverter DuctedFDUM & FDU Ducted Medium Static Series FDUM50ZIXVD

SRC50ZIX-S FDUM50VD

FDUM60ZIXVDSRC60ZIX-S FDUM60VD

FDU71VNXVDFDU71VNX FDU71VD

FDU100VNVDFDU100VN FDU100VD

FDU125VNXVDFDU125VNX FDU125VD

FDU140VNXVDFDU140VNX FDU140VD

Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)

Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 1.52 1.86 2.15 2.88 3.44 4.2

Heating H1 1.41 1.96 2.15 2.99 3.67 4.3Energy Label 2011 Cooling Stars 2 2 2 2 2 1.5

Heating 3 2 2.5 2.5 3 2.5EER Cooling T1 3.29 3.01 3.3 3.47 3.63 3.33COP Heating H1 3.82 3.42 3.72 3.74 3.81 3.72Current Cooling T1 Amp 6.7 8.2 9.6 12.7 15.3 18.6

Heating H1 6.3 9.0 9.5 13.1 16.3 19.1

Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)

Cool Ind dB 35~34~31~28 38~34~31~28 41~37 42~37 43~38Heat Ind 47 48 51 49 50 52

Sound Power Level (JIS C9612)

Outdoor dBA 62 65 66 70 72

Airflow Indoor L/S 233~216~200~183 300~266~250~233 333 ~ 283 566 ~ 450 700 ~ 558External Static Pressure

Indoor Pa 85 @ 233 l/s 85 @ 300 l/s 60/130 @ 333 l/s 60/130 @ 566 l/s 60/130 @ 700 l/s

External Dimensions (H x W x D)

Indoor mm 299 x 750 x 635 299 x 950 x 635 297 x 850 x 650 350 x 1370 x 650Outdoor 640 x 872 x 290 750 x 968 x 340 845 x 970 x 370 1300 x 970 x 370

Nett Weight Indoor Kg 34 40 40 63Outdoor 43 60 81 105

Refrigerant Piping Liquid Line mm (in)

6.35 (1/4") 9.52 (3/8”)Gas Line 12.7 (1/2") 15.88 (5/8”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 1.4 2.95 3.8 4.5m 15 30

Max. Piping Length Overall/Height m 30/20 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-KIT3-E

Ducted Split Systems - Medium & High Static

AC10

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

UNDER CEILING SPLIT SYSTEMS, ACCESSORIES

Reverse Cycle Inverter Under Ceiling - R410aRealcoldStock No.

MitsubishiModel No.

Refrigerant Cap kW T1 Nominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC3701 FDEN71VNXVD R410a 7.1 (3.2~8.0) 50~41~39~38 37 230/1/50 4,600.008.0 (3.6~9.0) 51 60

AC3702 FDEN100VNVD R410a 10.0 (4.0~11.2) 46~44~41~39 49 230/1/50 5,800.0011.2 (4.0~12.5) 49 81

AC3703 FDEN125VNXVD R410a 12.5 (5.0~14.0) 50~46~44~43 49 230/1/50 6,400.0014.0 (4.0~17.0) 50 105

AC3704 FDEN140VNXVD R410a 14.0 (5.0~16.0) 50~46~44~43 49 230/1/50 6,990.0016.0 (4.0~18.0) 52 105

Specifications - Reverse Cycle Inverter Under CeilingFDEN Under Ceiling Series FDEN71VNXVD

FDC71VNX FDEN71VD

FDEN100VNVDFDC100VN FDEN100VD

FDEN125VNXVDFDC125VNXFDEN125VD

FDEN140VNXVDFDC140VNXFDEN140VD

Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)

Heating H1 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 2.11 2.85 3.86 4.98

Heating H1 2.11 2.97 3.77 4.69Energy Label 2011 Cooling Stars 1 2 1 0.5

Heating 2 2.5 2 1.5AEER Cooling T1 3.36 3.51 3.23 2.81ACOP Heating H1 3.79 3.77 3.71 3.41Current Cooling T1 Amp 9.1 12.5 17.1 22.1

Heating H1 9.1 13.0 16.7 20.8

Recommended Circuit Breaker Amp 20 32Sound Pressure Level (JIS C9612)

Cool Ind dB 50~41~39~38 46~44~41~39 50~46~44~43Heat Ind 51 49 50 52

Sound Power Level (JIS C9612)

Outdoor dBA 66 70 70 72

Airflow Indoor L/S 366~300~233~200 466~433~383~350 533~483~433~383External Dimensions (H x W x D)

Indoor mm 210 x 1320 x 690 250 x 1620 x 690Outdoor 750 x 968 x 340 845 x 970 x 370 1300 x 970 x 370

Nett Weight Indoor Kg 37 49Outdoor 60 81 105

Refrigerant Piping Liquid Line mm (in)

9.52 (3/8")Gas Line 15.88 (5/8")Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 2.95 3.8 4.5m 30

Max. Piping Length Overall/Height m 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-E-E

Mitsubishi Heat Pump AccessoriesRealcoldStock No.

MitsubishiModel No.

Description System Price$ Excl. GST

AC3901 RCN-KIT3-E Infra red kit for FDU/M 296.00AC3902 RC-E4 Wired Remote controller for all indoor units 140.00AC3903 RCH-E3 Simple wired remote control - 2 wire 180.00AC3904 SC-ADNA-E Superlink adaptor for SRK and FD (RC-E4) 210.00AC3905 CnT Card connector flying leads 25.00AC3906 SC-THB-E3 Remote sensor 91.00AC3907 CW-H-E Base Heater kit for FDC125VNX and FDC140VNX POAAC3908 PCA006A057B PC Mente Interface 400.00AC3910 SC-BIKN-E Interface PCB for SRK and FD (RC-E4) 125.00

UNDER CEILING SPLIT SYSTEMS, ACCESSORIES

AC11

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

GREE ECO WINDOW-WALL SERIES

THE PROFESSIONAL’S CHOICE

Reverse Cycle Window - Wall - R410aRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Noise dBAHigh/Low

Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5015 GJH09AB-K3MNB8A R410a 2.7 49 43 230/1/50 615.00

2.4 45

AC5016 GJH12AD-K3MNB8A R410a 3.5 53 54 230/1/50 740.00

3 49

AC5017 GJH18AC-K3MNB8A R410a 5 55 73 230/1/50 890.00

4.7 51

AC5018 GJH24AC-K3MNB8A R410a 6.2 58 75 230/1/50 1,025.00

6 53

Features & Benefits

• Exceeds the 2011 MEPS III annulised ratings

• R410a Refrigerant

• 4 Way Air Flow

• Easy Clean Filter

• 5 Year Parts and Labour Warranty, domestic use only

• 4WayAirFlow • Longdistanceairing

• EasyCleanedFilter• EconomicSleepMode

Specifications - Gree ECO Window-Wall SeriesGree ECO Window-Wall Series GJH09AB-K3MNB8A GJH12AD-K3MNB8A GJH18AC-K3MNB8A GJH24AC-K3MNB8A

Power Supply Outdoor Unit 1 phase 230V 50Hz

Capacity Cooling T1 kW 2.7 3.5 5 6.2

Heating T1 2.4 3 4.7 6

Input Cooling T1 kW 0.9 1.25 1.75 2.05

Heating T1 0.8 1 1.56 1.75

Energy Label 2011 Cooling Stars 1 1 1.5 1.5

Heating 1.5 1.5 1.5 1.5

AEER Cooling T1 3 2.9 2.9 3.02

ACOP Heating T1 3 2.9 2.9 3.43

Current Cooling T1 Amp 4.83 6.5 10.5 13

Recommended Circuit Breaker Amp 16 20

Sound Pressure Level (JIS C9612)

High dBA 49 53 55 58

Low 45 49 51 53

Airflow Indoor L/S 138 216 230 250

External Dimensions (H x W x D)

Indoor mm 375 x 560 x 618 428 x 660 x 700

Nett Weight Kg 43 54 73 75

Refrigerant R410a Pre-charged Kg 0.78 0.81 1.07 1.4

Gree Eco Window-Wall Series

Gree Electric - Heat Pumps

AC12

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

GREE COZY HIGH-WALL SPLIT SYSTEMS

THE PROFESSIONAL’S CHOICE

Fixed Speed - R410aRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC5452G/W GWH09MB-K3NNA*B R410a 2.74 32 10 230/1/50 750.00

2.85 50 40

AC5454G/W GWH12MB-K3NNA*B R410a 3.38 32 10 230/1/50 850.00

3.26 52 41

AC5456G/W GWH18MC-K3NNA*B R410a 5.28 38 13 230/1/50 1,190.00

5.7 54 46

AC5458G/W GWH24MD-K3NNA*B R410a 6.15 46 15.5 230/1/50 1,490.00

6.75 58 64

Features & Benefits

• Fixed speed heat pumps are a viable alternative to expensive and complicated inverter air conditioners

• With over a three to one ratio, fixed speed heat pumps are an energy efficient way of heating your home

• Exceeds the 2011 MEPS III annulised ratings

• 5 metre connection cable included

• Healthy filter options

• 5 Year Parts and Labour Warranty, domestic use only

• ActiveCarbonFilter• High-efficientcurved heat exchanger

• SuperQuietOperation • EasyCleanFlatPanel

Specifications - Gree Cozy High-Wall Split SystemsGree Cozy High-Wall Split Systems GWH09MB-K3NNA*B GWH12MB-K3NNA*B GWH18MC-K3NNA*B GWH24MD-K3NNA*B

Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.74 3.38 5.28 6.15

Heating T1 2.85 3.26 5.7 6.75Input Cooling T1 kW 0.8 0.99 1.7 2.04

Heating T1 0.84 0.97 1.85 2.23Energy Label 2011 Cooling Stars 2 2 1.5 1.5

Heating 2 2 1.5 1.5AEER Cooling T1 3.42 3.41 3 3.01ACOP Heating T1 3.39 3.36 3.17 3.03Current Cooling T1 Amp 3.82 4.29 8.29 9.81Recommended Circuit Breaker Amp 10 16 20Moisture Removal L/H 2.5 2.5 3 4Sound Pressure Level (JIS C9612)

Indoor dBA 32 32 38 46Outdoor 50 52 54 58

Airflow Indoor L/S 167 167 217 222External Dimensions (H x W x D)

Indoor mm 275 x 845 x 180 298 x 940 x 200 315 x 1,007 x 219Outdoor 540 x 780 x 320 592 x 780 x 320 680 x 846 x 378 790 x 920 x 427

Nett Weight Indoor Kg 10 13 15.5Outdoor 40 41 46 64

Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 1.23 1.02 1.55 2.1m 5 5 5 5

Max. Piping Length Overall/Height m 15 20 25

Gree Cozy High-Wall Split Systems

AC13

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

GREE COZY HIGH-WALL INVERTER SPLIT SYSTEMS

THE PROFESSIONAL’S CHOICE

Reverse Cycle Inverter High-Wall - R410aRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal~Range

Noise dBAIND/OUT

Weight (Kg)IND/OUT

ElectricSupply

System Price$ Excl. GST

AC7170G/W GWH09MB-K3DNA*H R410a 2.5 (0.35~3) 40~32 9 230/1/50 1,050.00

2.8 (0.75~3.5) 50 35

AC7171G/W GWH12MB-K3DNA*H R410a 3.5 (0.95~4) 42~33 11 230/1/50 1,250.00

3.85 (0.88~4.3) 52 36

AC7172G/W GWH18MC-K3DNA*H R410a 5 (1.26~6.15) 49~35 13 230/1/50 1,550.00

5.56 (1.12~6.3) 52 47

AC7173G/W GWH24MD-K3DNA*H R410a 6.3 (1.4~6.8) 46~33 16 230/1/50 1,750.00

6.76 (1.2~8) 54 50

AC7174G/W GWH24ME-K3DNA*H R410a 7.2 (1.4~8.7) 47~40 17,5 230/1/50 1,990.00

8.2 (1.05~10) 59 65

Features & Benefits

• New 180 Deg Sine Wave Inverter

• Lowest Energy Consumption

• Ultra Low Noise

• Exceeds the 2011 MEPS III annulised ratings

• 5 metre connection cable included

• Healthy filter options

• 5 Year Parts and Labour Warranty, domestic use only

• ActiveCarbonFilter• High-efficientcurved heat exchanger

• SuperQuietOperation • EasyCleanFlatPanel

Specifications - Gree Cozy High-Wall Inverter Split SystemsGree Cozy High-Wall Inverter Split Systems GWH09MB-

K3DNA*HGWH12MB-K3DNA*H

GWH18MC-K3DNA*H

GWH24MD-K3DNA*H

GWH24ME-K3DNA*H

Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.6 (0.35~3) 3.5 (0.95~4) 5.2 (1.26~6.15) 6.3 (1.4~6.8) 8 (1.4~8.7)

Heating T1 2.8 (0.75~3.5) 3.85 (0.88~4.3) 5.8 (1.12~6.3) 6.3 (1.2~8) 8.4 (1.05~10)Input Cooling T1 kW 0.73 0.98 1.59 1.93 2.46

Heating T1 0.78 1.07 1.79 1.93 2.55Energy Label 2011 Cooling Stars 2.5 2.5 1.5 1.5 1.5

Heating 2.5 2.5 1.5 1.5 1.5AEER Cooling T1 3.55 3.56 3.24 3.24 3.23ACOP Heating T1 3.57 3.59 3.24 3.24 3.27Current Cooling T1 Amp 3.26 4.43 6.9 8.8 10.8Recommended Circuit Breaker Amp 10 15 20Moisture Removal L/H 1 1.4 2 2.5 2.5Sound Pressure Level (JIS C9612)

Indoor dBA 32 33 35 33 40Outdoor 50 52 54 59

Airflow Indoor L/S 137 163 236 250 320External Dimensions (H x W x D)

Indoor mm 265 x 790 x 170 370 x 918 x 258 298 x 940 x 200 315 x 1,008 x 219 326 x 1,178 x 253Outdoor 540 x 776 x 320 595 x 881 x 363 700 x 955 x 424 700 x 955 x 424 790 x 920 x 427

Nett Weight Indoor Kg 9 11 13 16 17.5Outdoor 35 36 47 50 65

Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 6.35 (1/4”) 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare

Refrigerant R410a Pre-charged amount

Kg 0.8 1.15 1.1 1.4 1.8m 5 5 5 5 7.5

Max. Piping Length Overall/Height m 20 30

Gree Cozy High-Wall Inverter Split Systems

AC14

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

GREE MULTI HEAD SYSTEMS

THE PROFESSIONAL’S CHOICE

Inverter Free Match - Multi Outdoor UnitsRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Min ~ Max No of Heads Noise dBAOUT

Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5274 GWHD(24)NK3AO R410a C7.1 C2.9~8.3 2 58 68 230/1/50 2,390.00

H8.5 H1.6~9.8 59

AC5276 GWHD(24)NK3CO R410a C7.1 C2.7~10 2 ~ 3 54 75 230/1/50 2,790.00

H8.5 H2.8~11 60

DC Inverter Free Match - Trendy High-Wall SeriesRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Ind dBA Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5250 GWHD(07)BANK3A1AI R410a C2.1 28~37 8.5 230/1/50 340.00

H2.5

AC5252 GWHD(09)BANK3A1AI R410a C2.5 28~38 8.5 230/1/50 380.00

H3.2

AC5254 GWHD(12)BBNK3A1AI R410a C3.5 30~40 11 230/1/50 420.00

H3.9

AC5256 GWHD(18)BCNK3A1AI R410a C5.0 36~46 13 230/1/50 490.00

H5.7

Ducted Series - Low Static Bulk HeadRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Ind dBA Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5260 GFHD(09)AANK3A1AI R410a C2.5 30~37 27 230/1/50 550.00

H3.2

AC5261 GFHD(12)AANK3A1AI R410a C3.5 33~40 27 230/1/50 650.00

H3.9

AC5263 GFHD(18)AANK3A1AI R410a C5.0 33~42 36 230/1/50 750.00

H5.7

Floor Console SeriesRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Ind dBA Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5265 GTHD(09)AANK3A1AI R410a C2.5 32~45 27 230/1/50 560.00

H3.2

AC5266 GTHD(12)AANK3A1AI R410a C3.5 36~46 27 230/1/50 595.00

H3.9

AC5267 GTHD(18)AANK3A1AI R410a C5.0 47~54 27 230/1/50 650.00

H5.7

Cassette SeriesRealcoldStock No.

GreeModel No.

Refrigerant Cap kWNominal

Ind dBA Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC5268 GKHD(12)ABNK3A2AI R410a C3.5 36~44 20 230/1/50 890.00

H3.9

AC5269 GKHD(18)ABNK3A2AI R410a C5.0 39~47 20 230/1/50 990.00

H5.7

Gree Multi Head Systems

AC15

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

GREE MULTI HEAD SYSTEMS

Allowable ConnectionsTwin Head Triple Head

Model GWHD(24)NK3AO GWHD(24)NK3CO

Nominal Capacity C7.0/ H8.7 C7.1/ H8.5

Total Combined Capacity C8.3/ H9.8 C10.0/ H11.0

Total Pipe Length/ Height 20/ 5 70/ 10

Recommended Match Plan for Indoor and Outdoor UnitsGWHD(24)NK3AO ~ 1 to 2 indoor units ~ 9 combinations

1 indoor unit 2 indoor units 3 indoor units

7 7 + 7 9 + 9

NONE9 7 + 9 9 + 12

12 7 + 12 12 + 12

GWHD(24)NK3CO ~ 2 to 3 indoor units ~ 24 combinations

1 indoor unit 2 indoor units 3 indoor units

NONE

7 + 7 9 + 9 7 + 7 + 7 7 + 9 + 12 9 + 9 + 9

7 + 9 9 + 12 7 + 7 + 9 7 + 9 + 18 9 + 9 + 12

7 + 12 9 + 18 7 + 7 + 12 7 + 12 + 12 9 + 9 + 18

7 + 18 12 + 12 7 + 7 + 18 7 + 12 + 18 9 + 12 +12

12 + 18 7 + 9 + 9 9 + 12 + 18 12 + 12 +18

kW Model Type 2.1 / 2.5 2.5 / 3.2 3.5 / 3.9 5.0 / 5.7

Hi-wall

Ducted

Floor

Cassette

THE PROFESSIONAL’S CHOICE

Gree Multi Head Systems

AC16

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

ENERGY RECOVERY VENTILATION

THE PROFESSIONAL’S CHOICE

RealcoldStock No.

GreeModel No.

Airflow (m3/hr) Max. External Static Pressure

ElectricSupply

System Price$ Excl. GST

AC5322 FHBQ-D3.5-K

H 350

100

220V~1Ph~50Hz

POAM 260

L 210

AC5324 FHBQ-D5-K

H 500

100 POAM 380

L 300

AC5326 FHBQ-D8-K

H 800

110 POAM 600

L 480

AC5328 FHBQ-D10-K

H 1000

110 POAM 750

L 600

AC5330 FHBQ-D15-M 1500 150 150

380V ~ 3Ph ~50Hz

POA

AC5332 FHBQ-D20-M 2000 150 150 POA

AC5334 FHBQ-D30-M 3000 220 220 POA

Accessories

• All units come with a simplified wired controller. Humidity Sensor Optional.

Gree Energy - Recovery Ventilation Systems

This Energy-Recovery Ventilation Systems supplies modulated fresh air to improve the indoor air quality. The high heat exchange efficiency offers up to 70% temperature exchange efficiency. Heat recovery ventilation systems can reduce the loading on air conditioners / heat pumps by 26%, based on annual operation.

• High Heat Exchanger Efficiency

• Remarkable Energy Savings

• 7 models available from 97 - 833 l/s

• Flexible Control Functions

o 50 - 50 air discharge / supply

o Positive or negative room pressure

o Weekly control for on - off timer

o Humidity control (optional)

o Centralized Remote Control (optional)

• Long Distance Control (optional)

• Easy installation & maintenance

• Long life and washable filters and heat exchanger

Energy Recovery Ventilation

AC17

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CURTAINS

Eclipse Air CurtainsRealcoldStock No.

EclipseModel No.

Length (mm) Fan Diameter (mm)

Input Power Watts

Air Speed (m/sec)

Noise dBA Weight (Kg) ElectricSupply

System Price$ Excl. GST

AC7500 FM-1.25-09 900 125 130 8 60 20 230/1/50 567.00

AC7501 FM-1.25-12 1200 125 170 8 60 24 230/1/50 613.00

AC7502 RM-1.5-09D 900 150 6300 7 64 26 230/1/50 1,025.00

Specifications - Air CurtainsFM-1.25-09 FM-1.25-12 RM-1.5-09D

Cabinet Dimensions (mm) 900 x 215 x 193 1200 x 215 x 193 900 x 383 x 266

Min Install Height 2.5m 2.5m 3.5m

Max Install Height 3.0m 3.0m 4.0m

Remote No No Yes

Electric Heater No No Yes

Features & Benefits

• Adjustable air fins allow for the exact control of air for special applications such as sloping walls and cross winds.

• Front Return Air Grille.

• 2 Speed Fans.

• Operating Temperature range -15 to +50 ˚C.

• 125mmm & 150mm Diameter Fan.

• Easy Mounting System.

• Remote Control on heating model.

• 12 months warranty on parts only.

Air Cutains - The New Advantage in the Energy Battle

• Energy Savings: Recent studies have shown that by fitting an air curtain will save significant amounts of energy by providing environmental seperation between indoor and outdoor temperatures. Pay back for some commercial appliactions can be as little as 21 weeks.

• Improved Indoor Air Quality: Air curtains prevent dust, dirt and fumes from infiltrating and contaminating indoor areas.

• Lower Construction Costs: With the use of air curtains Architects can design building without vestibules, saving construction costs and by eliminating the vestibule, providing more retail floor space.

• Improved Working Conditions: Keeps out cold air at door openings and recirculates warm air from ceiling to floor for more comfortable working conditions.

Eclipse Air Curtains

AC18

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING

Evaporative Air Conditioning - Cool Breeze

Cool Breeze is the smart choice for top FRESH air conditioning performance & the best value for money system around.

Cool Breeze Evaporative Air Conditioning

AC19

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING

Evaporative Air Conditioning - Cool Breeze

Cool Breeze evaporative air conditioning is the natural healthy way to cool your office, factory, showroom, warehouse or home.

Unlike refrigerated air conditioning systems where air is dried, chilled and re-circulated, a Cool Breeze evaporative system uses the natural element of water to cool the air. The air is always fresh because stale air is continually expelled through open doors and windows.

This technology, although enjoying enormous growth, is still largely underutilized and unknown in many parts of the world. EAC can provide cooling and ventilation with minimum energy consump-tion and without the use of ozone depleting chemicals such as CFC’s and HFC’s.

The principle of EAC is simple and commonly found in nature. For example, warm air passing over the ocean is cooled through the evaporative process before it reaches the mainland. This occurs because the warm air causes the water to evaporate and as the water evaporates, it absorbs the heat from the warm air, thereby cooling it.

In a modern evaporative air conditioner water is pumped from the base of the cooler onto the top of the pads. The important function of the fan is to draw air from the outside through the moisture laden filter pads, and then force the cooled air into the ductwork to be distributed into the building. It is therefore important to have some openings, such as doors or windows, sufficiently open to allow all the air in the building to escape.

Evaporative Cooler Selection Formula

Room Volume x 25 Air Changes = m3/hr

Convert to Litre/Sec

m3/hr ÷ 3600 x 1000 = Litre/Sec

For Example:

Room 24m x 12m x 4.5 m = 1296m3

1296m3/hr x 25 air changes = 32,400m3/hr

32,400 ÷ 3600 x 1000 = 9000 litres/sec

The table below (based on 90% humidity) shows the temperature drop that can be achieved at different levels of humidity. Note that the level of humidity will affect the temperature drop possible, however in the last 5 years many technological advancements have greatly improved the cooling capacity and performance of evaporative coolers.

Air-Changes Selection Table For Various Ambient Air Properties

Temp Ambient Degrees C

Relative Humidity Percentage %

20% 30% 40% 50% 60% 70%

25 13.5 15.5 17.0 19.0 20.5 22.0

30 16.5 19.0 21.0 23.0 25.0 26.5

35 20.2 22.5 25.0 27.5 29.5 31.0

40 23.0 26.0 29.0 31.5 33.5 36.0

45 27.0 30.0 32.5 35.5 38.0 40.5

Based on 90% saturation efficiency

AC20

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING

Down Discharge ModelRealcoldStock No.

Cool BreezeModel No.

kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST

AC8000 D095 7.0 600 75 2000 l/s POA

AC8001 D125 9.0 600 75 2800 l/s POA

AC8002 D160 11.0 750 100 3500 l/s POA

AC8003 D195 13.0 1000 100 4200 l/s POA

AC8004 D230 15.0 1000 100 5000 l/s POA

AC8005 D255 17.0 1000 100 5400 l/s POA

Note: Some models may be available on an indent only basis

Down Discharge Model - Twin FanRealcoldStock No.

Cool BreezeModel No.

kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST

AC8007 FD500 34 2 x 1000 100 mm 10,000 l/s POA

Note: Some models may be available on an indent only basis

Features & Benefits

• Dropper Duct Size 550 mm x 550 mm.

• Dropper Length - minimum allows for 150 mm roof truss & 500mm dropper spigots.

• Up to 24 degree roof pitch 1200 mm

25 degree to 29 degree 1300 mm

30 degree to 34 degree 1500 mm

35 degree plus 1800 mm

• Colour - Beige.

• 12 months warranty on parts only. QM Wall Control

Features & Benefits

• Dropper Duct Size 1165 mm x 585 mm.

• See Quietflo componentry price list for high capacity plenum to suit dropper size.

• Inside view including twin fan layout shown.

• Colour - Beige.

• 12 months warranty on parts only.

CPR Wall Control

AC21

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING

Top Discharge ModelRealcoldStock No.

Cool BreezeModel No.

kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST

AC8008 FT195 13.0 1000 100 4200 l/s POA

AC8009 FT230 15.0 1000 100 5000 l/s POA

AC8010 FT255 17.0 1000 100 5400 l/s POA

Note: Some models may be available on an indent only basis

Side Discharge ModelRealcoldStock No.

Cool BreezeModel No.

kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST

AC8011 S100 8 600 75 2200 l/s POA

AC8012 S240 15 1000 100 5100 l/s POA

Note: Some models may be available on an indent only basis

Features & Benefits

• Unit is supplied standard with ground mounting kit. Optional wall mounting bracket set is available (Refer to accessories section).

• Flexible outlet connector is supplied. It will attach to a duct adaptor from 500 mm to 700 mm square.

• Colour - Beige.

Features & Benefits

• Colour - Beige.

• No Optional bleed-off with side discharge systems.

• 12 month warranty on parts only.

S100. The S100 may be discharged through an optional wall register or duct adaptor. (Refer to accessories section) Alternatively discharge through any appropriate duct adaptor with an internal spigot measurement of 532mm and a minimum spigot length of 30mm.

A stud wall adaptor for use with the optional wall register should be fitted when the mounting wall thickness is less than 230mm. (Refer to accessories section).

S240. Supplied standard with floor mounting bracket. To attach to a wall, purchase an S240 side discharge wall mounting bracket set. (Refer to accessories section).

Flexible outlet connector supplied. It will attach to a duct adaptor from 550mm to 700mm square.

If the S240 is discharging directly through a side wall register into a working or living environment, in order to reduce fan noise, it may be necessary to operate the system at a lower fan speed and therefore the overall cooling capacity will be reduced.

AC22

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING

Mobile ModelRealcoldStock No.

Cool BreezeModel No.

kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST

AC8013 M240 17 1000 100 5400 l/s POA

Note: Some models may be available on an indent only basis

Features & Benefits

• Tank water capacity 100 litres.

• Colour - Dark Blue.

• Water Inlet - 19 mm male connection for constant water feed via hose pipe.

• Access for manual water fill.

• Large wheels with brakes for full mobile operation.

• It is essential that the Mobile unit is situated near an open door or window to facilitate a constant supply of fresh outside air. Adequate reliefair of at least 4 square metres is required, preferably allowing the cooled air to traverse the area to be cooled before venting to the outside.

• It is essential that the tank be drained at the end of each full day of operation to ensure a minimum concentration of minerals in the tankwater. Failure to do this will reduce the life of the Celdek pads and lower cooling efficiency.

• Includes steel frame which provides more rigidity and allows for transport.

• Note Six Speed Controller is also included - simply rotate the dial to choose your desired fan speed. Fan Only Operation is also available; simply switch off the COOL MODE to circulate fresh outside air.

• 12 months warranty on parts only.

AC23

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE AIR CONDITIONING - ACCESSORIES

Quietflo Plenums - AGP Series With 4 Way PyramidRealcoldStock No.

Cool BreezeModel No.

Description System Price$ Excl. GST

AC8220 QFPA2 AGP2 (D095 - D160) POA

AC8221 QFPA3 AGP3 (D195 - D255) POA

AC8224 QFPA4 AGP4 (FD500 Model) POA

Note: All Quiet Flo Accessories are available on an indent only basis

Plenums AdaptorsRealcoldStock No.

Cool BreezeModel No.

Description System Price$ Excl. GST

AC8222 QFPA2 AGP2 (D095 - D160) POA

AC8223 QFPA3 AGP3 (D195 - D255) POA

AC8225 QFPA4 AGP4 (FD500 Model) POA

Note: To suit above Plenums and 550² Dropper. Moulded from ABS Plastic

Adaptor 2

AGP2

AGP3

AGP4

Adaptor 4

Adaptor 3

Accessories

AC24

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE COOLING

“Wind & Water - Natures own cooling process”

As the term implies - evaporative cooling works by evaporat-ing water into the air stream. This principle is best illustrated in a personal way by that chilling effect you feel when you come out of a swimming pool and a breeze blows across your body. The chilling effect is caused by the evaporation process of the water drying quickly from your body. The same thing happens when you sweat. A “cool breeze” is just air flowing over your body evaporating the sweat. It is nature’s way of keeping us cool during hot weather or physical exertion.

Temperature is measured in two important ways that relate to evaporative cooling. These are “dry bulb” and “wet bulb” tem-peratures expressed in degrees Celsius. There are several other measurements that reflect the amount of moisture in the air. These are “wet bulb depression”, “saturation efficiency”, “dew point”, “kilograms of moisture per kilogram of dry air”, “absolute humidity”, and “relative humidity”. The following brief explana-tion of these measurements will help in the understanding of the process:

Dry Bulb: The ambient (surrounding air) temperature taken with a standard thermometre.

Wet Bulb: The lowest temperature of the air that can be reached by the evaporative cooling process.

Wet Bulb Depression: The difference between the Dry Bulb and Wet Bulb temperatures. I.e. If Dry Bulb is 38C and the Wet Bulb is 21C, the Wet Bulb Depression is 17C. The Wet Bulb Depres-sion is used to determine the efficiency percentage of the cooling media.

Cooling Efficiency or Saturation Efficiency: The percentage tem-perature drop across the media compared to the Wet Bulb De-pression. I.e. If the Wet Bulb Depression is 17 C as above, and the actual temperature drop measured across the media is 14C, the cooling efficiency of the media is 14/17 x 100 = 82.35%. The cool-ing efficiency is commonly referred to as “Saturation Efficiency” as it refers to the amount of moisture that can be evaporated into the air. 100% saturation efficiency would indicate a temperature drop of 17C in the above example of Wet Bulb Depression.

Dewpoint: The temperature at which moisture begins to form on a slick surface indicating 100% saturation of the air with mois-ture. That is how dew develops on grass in the morning. The Dry Bulb air temperature drops to the Wet Bulb temperature level.

Kilograms of moisture per Kilogram of dry air: a method of measuring actual water vapour (moisture) in a kilogram of dry air, most often referred to as the “humidity ratio”.

Absolute Humidity: Actual measurement of water vapour in the air.

Relative Humidity: The percentage of moisture in the air com-pared to the amount of moisture the air could contain. This is the most common reading to be reported in the weather reports.

Evaporation Rate: The rate at which water is absorbed into the air passing through the cooling media. For practical purposes, this rate is measured in litres per hour.

Evaporative Cooling Principles: Evaporative air conditioning functions efficiently in climatic conditions where the natural tem-perature of evaporation (wet bulb) is sufficiently low that the air cooled near this temperature by the process of evaporation can be used directly for air conditioning. The evaporation process involves an adiabatic exchange of heat effecting cooling, by ex-change of sensible heat for latent heat of vaporization of water. The temperature of air is reduced proportionally to the amount of evaporation that takes place, with a maximum theoretical dry bulb reduction equivalent to the difference between the prevail-ing wet and dry bulb temperatures.

The system operates by means of a water pump which supplies a continuous flow of water from a water reservoir to the evap-oration pads - CELDek. The in-flow of water to the reservoir is regulated by a float valve or solenoid valve controlled by a level sensor. 100% fresh air is drawn through the moist pads by the supply air fan. As air passes through the CELDek pads, evapo-ration takes place, cooling the air while maintaining a healthy humidity level.

The cool air is distributed via ducting through grilles and diffus-ers, replacing warm stale air, which is forced out through the open windows, doors or diffusers.

CELDek Cooling Medium

The evaporative pads in most modern evaporative air condi-tioners is a unique, long-life, self supporting pad made from a cellulose material, impregnated with anti-rot salts, rigidifying saturates and wetting agents. The CELDek design incorporates an exclusive cross-fluted configuration which induces a highly turbulent mixing between the cooling water and the air drawn through it. This action contributes to the efficiency of the evapora-tive pads. The construction of this media is unique in that it has alternating, transverse flutes at different angles. The larger pitch angle carries water (introduced to the top of the media) to the front of the media where the oncoming air forces it back into the media assisting in the thorough wetting of the media.

CELDek pads have brought a new dimension to the evapora-tive air conditioning industry - providing an effective and efficient method of humidity control and air cooling. Typical saturation ef-ficiency in a well designed evaporative air conditioner is around 80%.

EVAPORATIVE COOLINGEvaporative Cooling

AC25

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE COOLING

Benefits of CELDek cooling Medium

• A CELDek system does not sag, rot or developholes - allowing hot air to bypass the medium, or allow large quantities of water to drip.

• Duetotheuniquedesignandsaturationefficien-cy, it requires 40% less pad area than old conven-tional Aspen “wood-wool” type pads.

• With proper water management, the CELDekpads will last for years, therefore eliminating an-nual labour and material replacement costs.

• Filtration&Gasscrubber. Inaddition toCELDekshigh efficiency, low maintenance, and low re-sistance to air-flow - it also acts as a particulate filter for particles of 10 microns or greater and “rough cut” gas scrubber. The filtering character-istics should not alarm maintenance personnel, as the CELDek pads are self cleaning. A series of tests conducted by ‘Air Filter Testing Laborato-ries in Louisville, Kentucky, USA performed in ac-cordance to the dust spot efficiency test, ASHRAE Standard 52-76 , and the largest percentage of particles found in the upstream particle test were less than 0.5 microns in size.

• Further details on particulate removal capabilityof CELdek evaporative cooling media available on request.

• Low resistance to air-flow. At typical air veloci-ties of 1.5m/sec, the pressure drop through the CELdek pad is around 20Pa.

• Furtherdetailsonsaturationefficiencyandpres-sure drop through the CELdek available on re-quest.

The typical life of this media is between two and six years, pro-vided the water management system is operational.

Water Management - Water quality

Water always contains a certain amount of dissolved minerals. When evaporation takes place, the mineral concentration in the re-circulated water will increase. To avoid build-up of insoluble minerals - the re-circulating water is discharged by activating an electromechanical dump valve - flushing these accumulated minerals, dust and pollens with the water out of the sump - re-placing this water with fresh water. Alternative to a water dump system is a water bleed off system, where water is discharged whilst the pump is operational. The relation between the “bleed off” water rate and evaporated water volume depends on the quality of the water. To calculate the necessary bleed-off rate, a water analysis of the water feed must be done. Water losses by evaporation and “bleed-off” must be replaced by continuous adding fresh water to the evaporative cooled sump.

Systems which do not incorporate a water management sys-tem are subject to scaling on the pad surface, which causes a decrease in evaporation efficiency, increased resistance to air flow, reduced air volume, reduced life span, and excessive scale build-up in the water distribution system.

World Health Organisation recommended water conditions.

Insoluble minerals which cause scaling include calcium, bicar-bonates & sulphates.

Benefits of Evaporative Cooling

Evaporative air conditioning offers an affordable and practical means of cooling, its operation being at optimum efficiency in areas of high dry-bulb temperatures and low relative humidity. Most refrigerated air conditioning systems rely on recycled cool air, whereas evaporative air conditioning introduces a continu-ous supply of “ideally moistured” fresh, cool air. This naturally cooled, negatively ionised air does not dry nasal passages, skin or eyes, unlike the positively ionised, artificially cooled air from a refrigerated air conditioner. Air borne contaminants like dust and pollen are trapped in the CELDek pads, so the indoor condi-tions are cool, healthy and invigorating.

Economy: There is no compressor, condenser, chiller coils, cool-ing towers or heavily insulated piping used in evaporative cool-ing. The cost of acquisition and operation is a fraction of con-ventional air conditioning and mechanical refrigeration systems. Maintenance costs are minimal requiring simpler procedures and lower skilled maintenance people. An extra benefit is the cost payback due to its’ low energy use and extended useful life of equipment being cooled by it.

Effective: Evaporative cooling has been used for thousands of years in various forms for comfort cooling and is still in com-mon use around the world because of its simplicity, low cost and effectiveness. Unfortunately, many owners of buildings and specifiers of cooling equipment do not seem to realize that it is effective in all areas of the country rather than just in the hotter, drier climates. ASHRAE Handbook, 1995, chapter 47, Evapora-tive Air Cooling notes “...dry bulb temperature reduction due to the evaporation of water always results in a lower effective temperature, regardless of the relative humidity level” and that “...(Evaporative cooling) can provide relief cooling of factories al-most regardless of geographical location.”

Increased Comfort: In a large number of industries it is normal in hot weather to experience increased heat-related illness, lower productivity and increased absenteeism among workers. Many of these industries cannot afford the tremendous costs of conventional mechanical refrigeration or air conditioning, while they can afford evaporative cooling. Quoting again from ASHRAE Handbook, 1995, Chapter 47, Evaporative Air Cooling “evapora-tive cooling can alleviate this heat problem and contribute to worker efficiency with improved morale. If the heat problem is not alleviated, increased absenteeism, high labor turnover and dangers to health and safety during the summer months. Pro-duction declines in uncooled plants may range from 25% to 40% of normal on hot days.”

Health Benefits: Evaporative cooling is 100% fresh air cooling. This means that all the air being cooled is brought in from out-side. It is also necessary to force approximately 90% of all the air coming into the building, out of the building, leaving a nice 10% positive pressure. Today, the term “Sick Building Syndrome” exemplifies the result of continuously re-circulating the air inside the building. The old saying that you can get sick in a hospi-tal is true. The air containing contaminants of all sorts is being breathed in by everyone. In fact, the “no smoking” section of many public buildings is a joke. The same air permeates the en-tire building and is shared by all who breathe it. Fresh air would exhaust these contaminants quickly and harmlessly. National guidelines in building construction now require a percent of all air in the building be fresh air. To further improve the air quality, the rigid cooling media used in today’s evaporative coolers filters to near 1 micron size particles out of the air.

The answer to “Why Evaporative Cooling” is that it is Sensible cooling. It is an important tool in helping to curb the excessive use of energy. It helps clean up the atmosphere since it has no CFC’s or HCFC’s. It is economical, effective; it has health benefits, improves worker and equipment efficiency and provides a much needed alternative to conventional mechanical refrigeration!

Zero ozone depletion as evaporative cooling is a passive cool-ing method that does not use or expel harmful CFC’s.

AC26

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EVAPORATIVE COOLING

Typical Installations

Evaporative coolers can be installed in a multitude of applica-tions. See drawings of typical installations.

Applications

Homes, office buildings, factories, school halls, prisons, livestock confinement, greenhouses, laundries, make-up air for extrac-tion systems, automotive spray paint booths, vegetable storage buildings, gas turbine inlets, gymnasiums, workshops, printers, churches, bakeries entertainment including bars, night clubs, restaurants, cafes, in fact any application where ventilation and/or cooling is required.

Hygiene - Legionella Disease

Evaporative coolers should not be confused with cooling tow-ers or evaporative condensers, which have both been verified as potential Legionnaires’ disease transmitters. In contrast, no cases of Legionnaires’ have been attributed to evaporative cool-ers, for the following reasons.

Evaporative coolers vary substantially in operation and design from cooling towers and evaporative condensers. There are a variety of types including swamp coolers, air washers, humidi-fiers, slingers, atomizers and foggers.

The water used in evaporative coolers is usually from potable water supplies. This water normally contains dissolved miner-als, bacteria (including Legionella) and suspended solids. The air supplied to the cooler may contain a variety of contaminants including dust, dirt, bacteria (including Legionella), soluble gas-es and nutrients. A portion of these impurities are scrubbed by the water. When water evaporates, only pure water is released leaving the impurities behind to accumulate in the water.

The amount of accumulation depends on the water and air quality as well as the operation of the evaporative cooler. If the system is regularly drained, cleaned and allowed to dry out, the accumulations will be substantially reduced. These practices can further prevent the possibility of Legionnaires’ disease origi-nating from evaporative coolers.

Legionella growth is relative to the temperature of the water. It is active at a temperature range of 20C to 45C, with optimum growth occurring at about 37C to 41C. Legionella bacteria are found to be dormant at temperatures less than 20C and are re-tarded at temperatures above 50C. It does not survive in tem-peratures above 60C.

Evaporative coolers most often operate with water temperatures less than 24C, or slightly above the wet bulb temperature, and most often with water temperatures below 20C where Legionel-la bacteria are not active.

As with all microbiological organisms, Legionella bacteria re-quire nutrients and optimum water quality to proliferate. While water temperature is an important factor in bacteria growth, other conditions must exist. These include the presence of nutri-ents, sediments, and other micro-organisms in the water. These so-called dirty systems often provide favourable growth condi-tions of all types of bacteria, including Legionella.

Legionella bacteria enter the lungs via extremely small water droplets (aerosols) of 1 to 5 microns in size. The rod shaped bac-teria can only be transported by microns large enough to hold them. Rigid media type evaporative coolers release water main-ly as a vapour, this vapour is too small to transport the bacteria.

Legionnaires’ disease characteristics

It is important to discuss the causes of this disease and to under-stand how it is contracted. There are three conditions that must be satisfied before Legionnaires’ disease can be contracted:

• ThewatermustcontainviableLegionellabacteriain high levels;

• Finemists of a specific droplet size of the con-taminated water must be inhaled deeply into the lungs; and

• The person inhaling the contaminated finemistmust be susceptible (or have a suppressed im-mune system).

Typical Running Costs

Typical running costs in Auckland for a mid-range cooler with a total of 800w electrical power input, operating for eight hours per day is:

8 hours x 0.8kW x $0.1315/ kWhr = $0.84 in a domestic ap-plication

8 hours x 0.8kW x $0.1489/ kWhr = $0.95 in a commercial application

Calculating the Supply-Air temperature

Example using the wet bulb and dry bulb temperatures in this discussion.

• Tdb=38C

• Twb=21C

• Pad Efficiency 80% (This information is typicallyprovided by evaporative cooler manufacturer.)

Use the formula: T ins = Tdb - (Tdb - Twb) x pad efficiency/100

T ins = 38 - (38 - 21) x 80/100

T ins = 38 - 17 x 0,8

T ins = 38 - 13.6

T ins = 24.4 C

Calculating the Evaporative Air Conditioning Cooling Capacity (Sensible Cooling Capacity)

Example using the following details:

• ms=12000cubicmetresperhour

• TD=13.6C(aspertheaboveexample)

• Density1.2kg/cubicmetre

Use the formula: Qo = ms x TD x sh x air density

= 12000/3600 x 13.6 x 1.2

= 3.334 x 13.6 x 1.2

= 54.41kW sensible cooling.

We can provide assistance in design of evaporative cooling equipment. Starting with the size of the structure you want to cool, we can recommend the correct equipment size and offer different alternatives that could save a lot of time and money. If the need is to replace existing equipment, we can recommend units for that purpose. Sometimes the existing equipment can be made to work effectively by upgrading to a higher efficiency us-ing products like Cool Breeze. Whatever the evaporative cooling need, it would pay to contact us. A wealth of technical informa-tion is available at no cost!

Realcold Ltd.

AC27

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING ACCESSORIES

Mounting Brackets & BasesRealcoldStock No.

Model Description System Price$ Excl. GST

AC0603 AH-YDII Sloped Roof Bracket - For 5.0kW or smaller

Width 250 - 700 mm Depth 230 - 700 mm Slope 11° - 30° Max weight 75 Kg

186.00

AC0609 QKYL-1 Sloped Roof Bracket - For 3.5kW or smaller

Width 250 - 700 mm Depth 230 - 700 mm Slope 10° - 30° Max weight 60 Kg

174.00

AC0611 QKK-1 Wall Type - For 3.5kW or smaller

Width 260 - 760 mm Depth 130 - 360 mm Max weight 60 Kg

145.00

AC0613 AH-KL Wall Type - For 5.0kW or smaller

Width 330 - 630 mm Depth 130 - 360 mm Max weight 75 Kg

191.00

AC0634 QKB1 Flat Surface Type Bracket For 3.5kW or smaller

Width 100 - 600 mm Depth 130 - 330 mm Max weight 60 Kg

165.00

AC1310 CHBRCB-18 Wall Type 1.5 mm Painted Steel

Arms 450 mm Wall Mount 800 mm Max Weight 180 Kg

35.00

AC1311 CHBRCB-25 Wall Type 2.0 mm Painted Steel

Arms 500 mm Wall Mount 1,000 mm Max Weight 250 Kg

48.00

AC1301 CHBRCB-10S Realcold S/S Wall Type - 1.5 mm

Arms 480 mm Wall mount 750 mm Max Weight 75 Kg Stainless Steel 304

89.00

AC1302 CHBRCB-20S Realcold S/S Wall Type - 2.0 mm

Arms 600 mm Wall mount 1,000 mm Max Weight 150 Kg Stainless Steel 304

115.00

AC1303 CHBRRB-10S Realcold S/S Roof Type - 1.5 mm

Can be used as a wall bracket

Arms 480 mm Roof mount 800 mm Max Weight 75 Kg Stainless Steel 304

129.00

AC1304 CHBRRB-20S Realcold S/S Roof Type - 2.0mm

Can be used as a wall bracket

Arms 550 mm Roof mount 1,000 mm Max Weight 150 Kg Stainless Steel 304

185.00

AC1200 MCB450 - 450 mm Medium duty galvanised cantilever bracket 56.15

AC1201 HCB450 - 630 mm Heavy duty galvanised cantilever bracket 79.95

AC1208 Kit 1 c/w 4 x 10 mm coach bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps

20.00

AC1209 Kit 2 c/w 4 x 10 mm dyna bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps

20.20

AC1205 M1000 Galvanised steel channel - 3 metre length 68.00

AC1215 SNL-M8 8 mm channel spring nut 1.45

AC1216 SNL-M10 10 m channel spring nut 1.55

AC1220 PS465 Polyslab - Medium 38.65

Refer to page AC35 for Roof Penetration Kit - compliant with NZ Metal Roofing Code of Practise.

AH-YDII

QKYL-1

QKK-1

AH-KL

Stainless Steel Channels

HCB450

MCB450

QKB1

AC28

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING ACCESSORIES

Pre-Insulated Copper TubeRealcoldStock No.

Model Description Wall Thickness Swp System Price$ Excl. GST

Imperial Metric Imperial Metric kPA Psi

TOYO Pair Coil - 20 metre Coil

AC0002 TD-2320-8 1/4" x 3/8" 6.35 x 9.53 0.031 0.031 0.80 0.80 9835 x 6329 1427 x 919 POA

AC0003 TD-2420 1/4" x 1/2" 6.35 x 12.7 0.031 0.031 0.80 0.80 9835 x 4665 1427 x 677 POA

AC0004 TD-2520 1/4" x 5/8" 6.35 x 15.88 0.031 0.039 0.80 1.00 9835 x 4665 1427 x 677 POA

AC0005 TD-3520 3/8" x 5/8" 9.53 x 15.88 0.031 0.039 0.80 1.00 6329 x 4665 919 x 677 POA

AC0006 TD-3630Z 3/8" x 3/4" 9.53 x 19.05 0.031 0.047 0.80 1.20 6329 x 4665 919 x 677 POA

TOYO Single Coil - 20 metre Coil

AC0010 SD-220 1/4" 6.35 0.031 0.80 9835 1427 POA

AC0011 SD-320 3/8" 9.53 0.031 0.80 6329 919 POA

AC0012 SD-420 1/2" 12.7 0.031 0.80 4665 677 POA

AC0013 SD-520 5/8" 15.88 0.039 1.00 4665 677 POA

AC0014 SD-620Z 3/4" 19.05 0.047 1.20 4665 677 POA

REALCOLD Pair Coil - 20 metre Coil

AC0056 OPS-2320 1/4" x 3/8" 6.35 x 9.53 0.031 0.031 0.80 0.80 9835 x 6329 1427 x 919 POA

AC0057 OPS-2420 1/4" x 1/2" 6.35 x 12.7 0.031 0.031 0.80 0.80 9835 x 4665 1427 x 677 POA

AC0058 OPS-2520 1/4" x 5/8" 6.35 x 15.88 0.031 0.039 0.80 1.00 9835 x 4665 1427 x 677 POA

AC0059 OPS-3520 3/8" x 5/8" 9.53 x 15.88 0.031 0.039 0.80 1.00 6329 x 4665 919 x 677 POA

TOYO Aluminium Pair Coil - 20 metre coil c/w specialised flare nuts

AC0100 CAT-2320 1/4” x 3/8” 6.35 x 9.53 0.035 0.039 0.90 1.00 9200 x 6500 1334 x 942 120.00

AC0107 1/4" FNC 1/4" Flare nut and cap set 2.00

AC0108 3/8" FNC 3/8" Flare nut and cap set 2.50

Notes: 1) Values of SWP are derived from the formula from ANSI B31 Standard Code for Pressure Piping. 2) The value of Maximum Stress (S) used in the calculation is 150°F (65.6°C) and is for copper in its annealed condition. For pipe temperatures higher than 150°F (65.6°C), please contact your local Realcold branch for assistance in the selection of appropriate tube for your requirement.

DrainageRealcoldStock No.

Model Description System Price$ Excl. GST

AC0745 DRS Drainage Socket - Drain Y Connector 3.75

AC0749 DRH-14N Drain Hose 14 mm x 50m coil 53.60

AC0755 WRH-16N Drain Hose 16 mm x 50m coil LINED 74.80

AC0817 SDH-20JN Joint for 20 mm Drainage Hose 2.40

Drainage hose is made of Linear Low Density Polyethylene - light weight, high mechanical strength and better UV resistance (5000hr durable in weather testing).

Joint

The Tube Insulation is of double-layered structure made up of cross-linked, foamed, closed cell polyethylene.

The covering is of embossed polyethylene, free of defects, and does not crease when bent. Seamless extrusion is used to ensure close contact with the copper tube, and to enhance the dew-proofing properties. Heat resistance is up to 120º C. and the insulation is manufactured to JIS A9511 P2 Standard.

The Copper Tube is soft annealed and is to JIS H3300 C1220T Standard. R410a compatible.

AC29

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING ACCESSORIES

DuctingThis attractive ivory coloured ducting is easy to install. The slim, square design of the duct and accessories has an aesthetic appearance which will enhance any installation. The duct is made of highly durable, weatherproof PVC resin. Suitable for use in the temperature range -20 to +60ºC

RealcoldStock No.

Model Description Carton Quantities

System Price$ Excl. GST

AC0201 TD-80 80 mm Duct sold in 2 metre lengths 5 20.75

AC0202 TD-120 120 mm Duct sold in 2 metre lengths 4 53.15

Ducting is packed 5 Lengths (AC0201) or 4 Lengths (AC0202) to a Carton

AC0206 DC-80 80 mm Cap 20 8.80

AC0207 DC-120 120 mm Cap 10 21.65

AC0209 DK-80 80 mm Corner 20 8.80

AC0210 DK-120 120 mm Corner 6 21.65

AC0212 DF-80S 80 mm Flexible Joint 20 8.80

AC0213 DF-120 120 mm Flexible Joint 5 20.10

AC0215 DLW-80 80 mm 45º Elbow 20 9.30

AC0217 DL-80 80 mm 90º Elbow 20 10.85

AC0218 DL-120 120 mm 90º Elbow 10 21.65

AC0220 DJ-80 80 mm Joint 50 3.10

AC0221 DJ-120 120 mm Joint 20 9.30

AC0223 DE-80 80 mm End Socket 20 7.25

AC0224 DS-80 80 mm Ceiling Cap 20 11.85

AC0225 DT-120 120 mm T-Joint 5 41.75

AC0226 DB-120 120 mm Branch Joint 5 17.00

AC0227 DR-120 120 mm Reducing Joint 10 17.00

AC0228 WPC-60 Wall Pipe with Flange 60 7.25

AC0229 DS-120 120 mm Duct Ceiling Cap 10 28.85

RealcoldStock No.

Model Description Carton Quantities

System Price$ Excl. GST

AC0501 HB-330 Mounting Base, Ivory 330 mm 50 5.70

AC0503 HB-450 Mounting Base, Ivory 450 mm 30 10.85

AC0510 PQB-36 Quick Base 350 mm 20 11.85

AC0512 PQB-45 Quick Base 450 mm 20 17.55

AC0521 PQC-35 Quick Base Side Cover 8.80

AC0702 PT-1K Sealing Putty, Ivory Colour, Flame proof. 1Kg pack. 11.75

AC0709 VT50 X 20 Self-Adhesive Tape, Ivory 7.25

A mounting base which is designed to maintain the aesthetic qualities of the installation. The sophisticated design, lightweight, rigidity and portability give a considerable advantage over other mounting methods. Made of rigid, waterproof resin, it is suitable for use in the temperature range -20 to +60ºC.

AC0512/AC0521

AC0206/AC0207

AC0501/AC0503

AC0201/AC0202

AC0209/AC0210

AC0212

AC0224

AC0225

AC30

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING ACCESSORIES

Condensate Drain Pipe & FittingsRealcoldStock No.

Description System Price$ Excl. GST

uPVC Pressure Pipe (white) Air Cond & Refrig Drain Pipe

AC1001 15 mm AC&R (3.9 Metre Length) - Packs of 20 7.95

AC1003 20 mm AC&R (3.9 Metre Length) - Packs of 20 12.60

AC1005 25 mm AC&R (3.9 Metre Length) - Packs of 10 19.00

uPVC Pressure Pipe 90 Deg Equal Elbow

AC1010 15 mm Equal Elbow 1.45

AC1012 20 mm Equal Elbow 2.20

AC1014 25 mm Equal Elbow 3.30

uPVC Pressure Pipe 45 Deg Elbow

AC1018 15 mm Injection Mould Bend 2.00

AC1020 20 mm Injection Mould Bend 5.15

AC1022 25 mm Injection Mould Bend 6.00

uPVC Pressure Pipe Equal Tee

AC1028 15 mm Equal Tee 2.00

AC1030 20 mm Equal Tee 2.50

AC1032 25 mm Equal Tee 4.85

uPVC Pressure Pipe Double End Socket

AC1036 15 mm Double End Socket 0.85

AC1038 20 mm Double End Socket 1.25

AC1040 25 mm Double End Socket 2.60

uPVC Pressure Pipe Reducing Socket

AC1044 20 x 15 mm Reducing Socket 2.40

AC1046 25 x 15 mm Reducing Socket 3.20

AC1048 25 x 20 mm Reducing Socket 4.45

uPVC Pressure Pipe Reducing Bush

AC1052 20 x 15 mm Reducing Bush 0.95

AC1054 25 x 15 mm Reducing Bush 2.30

AC1056 25 x 20 mm Reducing Bush 2.60

uPVC Pressure Pipe Male Socket (grey)

AC1060 15 mm Male Socket 2.10

AC1062 20 mm Male Socket 2.10

AC1064 25 mm Male Socket 3.10

uPVC Pressure Pipe P/T Female Socket (grey)

AC1070 15 mm P/T Female Socket 2.10

AC1072 20 mm P/T Female Socket 2.70

AC1074 25 mm P/T Female Socket 3.55

AC31

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING ACCESSORIES

Condensate Drain Pipe & FittingsRealcoldStock No.

Description System Price$ Excl. GST

Solvent (Clear)

AC1078 125 ml Clear Solvent Type P 20.30

AC1080 250 ml Clear Solvent Type P 23.50

White Pipe Saddle (full)

AC1090 Full Pipe Saddle 15 mm 0.95

AC1092 Full Pipe Saddle 20 mm 0.95

AC1094 Full Pipe Saddle 25 mm 1.05

Zinc Plated Pipe Saddle (Single side)

AC1096 Single Sided Clip 15 mm 0.25

AC1098 Single Sided Clip 20 mm 0.25

EZ Trap - The Trap ExpertsRealcoldStock No.

Description System Price$ Excl. GST

20mm Transparent Cross Trap

AC1102 Cross Trap 42.85

Flexible Brush - Clean out your Trap

AC1108 Flexible Brush 11.55

Socket UnionRealcoldStock No.

Description System Price$ Excl. GST

AC1110 15 mm Socket Union / Mac Union / Connection 23.00

AC1112 20 mm Socket Union / Mac Union / Connection 45.25

AC1114 25 mm Socket Union / Mac Union / Connection 37.30

AC1102 20 mm

Transparent Trap

AC1108 Flexible Brush

AC1112 20 mm Socket Union / Mac Union / Connection

AC32

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

CONDENSATE PUMPS

Hi Lift PumpsRealcoldStock No.

Description System Price$ Excl. GST

T0911 Aspen Hi-lift Tank Pump 1.0 Litre Tank

Description: Peristaltic Rotary Type Pump. Designed to collect and pump a smaller volume of water to a greater head. Requires 230V supply only. Fits into a shallow ceiling void or unit.

Features: No siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Pumps water, fibrously contaminated water and air.

Technical: Pump rating 1ph, 0.4A, 230 VAC, 50Hz. Safety switch 4.0A max. Water flow rate 11 l/hr @ 12 metres head. Max head is 12 metres. Inlet 2 x 25 mm, outlet size is 6 mm. Tank capacity 1.0 litre.

Dimensions: 132 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.

298.00

T0912 Aspen Hi Lift Tank Pump 2.0 Litre Tank

Description: Peristaltic Rotary Type Pump. Designed to collect and pump a smaller volume of water to a greater head. Requires 230V supply only. Fits into a shallow ceiling void or unit.

Features: No siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Pumps water, fibrously contaminated water and air.

Technical: Pump rating 1ph, 0.4A, 230 VAC, 50Hz. Safety switch 4.0A max. Water flow rate 11 l/hr @ 12 metres head. Max head is 12 metres. Inlet 2 x 25 mm, outlet size is 6mm. Tank capacity 2.0 litres.

Dimensions: 160 mm high x 235 mm wide x 140 mm deep. Weight 2.0Kg.

315.00

Hi Flow PumpsRealcoldStock No.

Description System Price$ Excl. GST

T0913 Aspen Hi-Flow Condensate Pump 1.0 Litre

Description: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.

Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.

Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 1.0 litre.

Dimensions: 130 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.

157.00

T0914 Aspen Hi-Flow Condensate Pump 2.0 Litre

Description: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.

Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.

Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 2.0 litres.

Dimensions: 160 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.

157.00

Get AcTabs to prevent drain pan overflow and odours:

AC33

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

CONDENSATE PUMPS - WARRANTY PARTS ONLY

Universal PumpRealcoldStock No.

Description System Price$ Excl. GST

T0916 Aspen Universal Pump

Description: Peristaltic Rotary Type Pump. Self priming to 3m. Pumps water, fibrously contaminated water and air. Requires two sensores to read air on/off on the evaporator coil.

Features: Operates by sensing 5°C differential across the evaporating coil. 3 minute timer overrun on stop. No siphoning back. Operates only on cooling. Manual test switch. 3m connecting cable. Wall mounting bracket included. Made of fire retardant plastics.

Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz. Water flow rate 6.25 l/hr @ 12 metres head. Max head is 12 metres. Inlet / outlet size is 6 mm.

Dimensions: 142 mm high x 160 mm wide x 83 mm deep. Weight 1.5Kg.

313.00

Supermarket PumpRealcoldStock No.

Description System Price$ Excl. GST

T0960 Aspen Supermarket Pump

Description: This pump is designed to be installed underneath refrigeration chiller units to collect water during the defrost cycle.

Features: Operates on a hall effect float / sensor. Thermally protected 230V continuously rated motor. High level safety switch. Tank capacity 11 litres. Push-in plug connector. Fliter to catch debris. Made of fire retardant ABS plastics.

Technical: Pump rating 1ph, 0.35A, 230 VAC, 50Hz. Water flow rate 225 l/hr @ zero metres head. Max head is 30 metres. Inlet size 50 mm / outlet size is 10 mm. Water temp 0°C to 40°C.

Dimensions: 100 mm high x 590 mm wide x 405 mm deep. Weight 4.9Kg.

740.00

AC-Tabs

Actabs with its EPA registered biocide eliminates or prevents most blockages in air conditioning and refrigeration drain lines due to the buildup of bacterial slime, rust, scale, sludge, air bourne dust, silty and other solids.

• Unique automatic metering dispenser

• EPA Registered

• Prevents Costly Water Overflow Damage

• Eliminates Bacteria Casused Bad Odours

• Can be used in Computer Rooms

AC34

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

CONDENSATE PUMPS - WARRANTY PARTS ONLY

Compact Pumps - Hidden InstallationRealcoldStock No.

Description System Price$ Excl. GST

T0939 Aspen Mini Aqua*

Features: Our smallest pump ever fits all wall mount splits. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Mounts vertically or horizontally, Versatile and quiet operation.

Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. 21 dBA @ 1 metre.

Dimensions: 28 mm high x 165 mm wide x 28 mm deep. Weight 0.18Kg.

228.00

T0940 Aspen Mini Orange*

Features: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat.

Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. Suction lift 1 metre. 23 dBA @ 1 metre.

Dimensions: 51 mm high x 107 mm wide x 39 mm deep. Weight 0.25Kg.

228.00

T0941 Aspen Maxi Orange*

Features: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat.

Technical: Pump rating 1ph, 0.25A, 230VAC, 50Hz, 21 watts. Water flow rate 37 l/hr @ zero head. Max head 20 metres. Suction lift 1 metre. 35 dBA @ 1 metre.

Dimensions: 66 mm high x 122 mm wide x 44 mm deep. Weight 0.45Kg.

263.00

T0942 Aspen Mini Lime*

Features: Designed to be installed in the plastic conduit supplied. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Reversible. Box contains the pump, elbow, 800m conduit, connection sleeve and ceiling plate.

Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. 23 dBA @ 1 metre.

Dimensions: 79 mm high x 99 mm wide x 44 mm deep. Weight 0.31Kg.

289.00

Note: Pacific pumps use an electronic sensor. Mini Aqua, Mini Orange, Maxi Orange & Mini Lime pumps have an electro-mechanical sensor.*Warranty is null or void unless all pumps purchased are installed with inline filter T0926.

*Compact Pump In-Line FilterRealcoldStock No.

Description System Price$ Excl. GST

T0926 Condensate Filter PF2

Features: Removes sludge and dirt particles as well as hairs. Large surface area gives minimum intruption to water flow.

Technical: Failure to install a condensate filter can void the Compact Condensate Pumps warranty.

25.45

Anti Siphoning Device - BRAND NEW - Revolution From Aspen

• Theleadingsolutiontopreventsiphoning • Evenfasterandeasierinstallations

• Hasslefreecondensatepumpfitting • Uniqueandrevolutionarydesign

• Completepeaceofmind • Exclusively free with Aspen Mini Pumps

COMIN

G SOON

April 2012

AC35

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

Heat Pump AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

N0495 Top Hat Roof Penetration Kit contains:

• Dktite flexible flashing• PVC slotted pipe• PVC cover flashing• PVC cap• 12 hex head screws• Bostik sealant• Complies with NZ Metal Roofing Code of Practise

87.55

AC1701 Universal Remote Control for A/C Ultra Plus Hi-wall 95.00

CONDENSATE PUMPS - WARRANTY PARTS ONLY

Spares For PumpsRealcoldStock No.

Description System Price$ Excl. GST

T0905 Peristaltic Tubes 29.60

T0920 6 mm Clear Plastic Tubing for condensate pumps 1.80

T0922 Aspen non-return valve 6 mm 8.25

T0924 Aspen straight connector 5.60

T0926 Filter kit for all compact condensate pumps 25.45

T0927 Aspen Plastic Fitting 3.65

T0928 Aspen Universal Sensor 93.75

Compact Pumps - Below Wall Unit InstallationRealcoldStock No.

Description System Price$ Excl. GST

T0938 Aspen Mini Blanc Pump Deluxe

Features: Designed to sit below the indoor unit. Offers easy access for fast efficient servicing. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Cleanable / replacable 70 micron internal filter.

Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz, 16 watts. Alarm relay rated at 5A / 250VAC. Max water flow rate, 12 l/hr @ zero head. Max head 10 metres, 21 dBA @ 1m.

Dimensions: 115 mm high x 182 mm wide x 53 mm deep. Weight 0.46Kg.

222.00

Note: Pacific pumps use an electronic sensor. Mini Aqua, Mini Orange, Maxi Orange & Mini Lime pumps have an electro-mechanical sensor.*Warranty is null or void unless all pumps purchased are installed with inline filter T0926.

Heat Pump Accessories

AC36

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

ELECTRICAL & THERMOSTATS

Components & FittingsRange of electrical components to assist air conditioning installers.

RealcoldStock No.

Description Base Unit of Measure System Price$ Excl. GST

E1098 Weatherproof Switch 15A Unit 33.95

E1099 Weatherproof Switch 35A Unit 44.95

E2012 2.5 mm, 3 Core TPS, 2C + Earth Metre 1.99

E2026 1.5 mm, 4 Core TPS, 3C + Earth Metre 3.15

E2024 2.5 mm, 4 Core TPS, 3C + Earth Metre 4.40

E2020 Connector Terminal Single 40A Jar 32.00

E2023 Flex 25 mm Conduit Metre 2.95

Seitron Air Conditioning ThermostatsRealcoldStock No.

Model No Description System Price$ Excl. GST

Electronic Thermostats (Heatpumps)

G4520 TAEZN4MC Electronic Heatpump t/stst 230V AC - Use STLNTSA150 Sensor 174.00

G4521 TAEZN42C Electronic Heatpump t/stst 24V AC - Use STLNTSA150 Sensor 174.00

G4522 TAEZN2MC Electronic Heatpump t/stst 230V AC On / Off Switch - Use STLNTSA150 Sensor 182.00

G4523 TFEZN4MC Electronic Heatpump t/stst 230V AC On / Off & 3 Speed Fan Switches - Use STLNTSA150 Sensor

198.00

G4524 TFPF03MC Diamond Eelctronic programable Heat pump t/stat with Digital display, 230V AC - Use STLNTSA150 Sensor

190.00

Mechanical Heating / Cooling Thermostats

G4525 TAM011MI TAM, 16A Heating / 5A Cooling 8…30°C 230V AC 36.00

G4526 TAM013MI TAM, 5A 8…30°C 230V AC On / Off Switch 45.00

Electronic Heating Thermostat

G4527 Magictime Programable heating t/stat, 7 day/24hr digital analogue display - use STLOTSA150 NTC Sensor

202.00

Sensors and Accessories

G4553 STANP3 NTC Room Sensor for TAEZN / TFEZN series t/stats 49.00

G4554 Sensor Housing Plastic Sensor Housing 24.00

G4555 STLNTSA150 Remote NTC Sensor - Probe with 1.5m lead 4700ohm @ 25°C 39.00

G4556 STLOTPA150 Magictime Remote NTC Sensor 100kohm @ 25°C 39.00

AC37

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

Saginomiya 4-Way Reversing ValveRealcoldStock No.

Model Description Capacity Refrigerator Pipe Sizes Coil Voltage System Price$ Excl. GSTR22 R410a Discharge Suction & Coils

G1100 CHV-0201

STF-0201"G"

Reversing Valve C/W Coil

2.6 3 R22 R407c R410a

9.52 (3/8") 12.7 (1/2") YES 230V AC 50Hz

87.55

G1112 STF-0214"G" Reversing Valve C/W Coil

3 R22 R407c R410a

12.7 (1/2") 15.88 (5/8") YES 230V AC 50Hz

87.55

G1114 STF-0408"G" Reversing Valve C/W Coil

6 R22 R407c R410a

12.7 (1/2") 19.05 (3/4") YES 230V AC 50Hz

364.00

G1103 CHV-1511 Reversing Valve without Coil

10.9 n/a R22 R407c

22 (7/8") 28.5 (1.1/8") NO - POA

G1104 CHV-3001 Reversing Valve without Coil

25 n/a R22 R407c

32 (1.1/4") 38.4 (1.1/2") NO - POA

ACSG0301 SHF-7H-34U Reversing Valve without Coil

2 2.3 R22 R407c R410a

9.52 (3/8") 12.7 (1/2") NO - 105.00

ACSG0169 SHF-20A-46 Reversing Valve without Coil

5.7 6.7 R22 R407c R410a

12.7 (1/2") 19.05 (3/4") NO - 105.00

CHV Coils for Reversing Valves

G1105 CHV-01AI501A1

CHV Coil suits CHV/STF 101~2011

- - - - - - 230V AC 50Hz

31.45

G1106 CHV-MOAI1032B1

CHV Coil suits CHV/STF 2501~3001

- - - - - - 230V AC 50Hz

31.45

4 WAY VALVES

AC38

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DUCTING ACCESSORIES

Flexible DuctingRealcoldStock No.

Diameter (mm) Length (m) System Price$ Excl. GST

Comflex Nude

ACDCT0367100

3 8.35

ACDCT0409 6 16.70

ACDCT0368125

3 10.85

ACDCT0410 6 16.70

ACDCT0369150

3 13.95

ACDCT0411 6 17.25

ACDCT0377200

3 12.30

ACDCT0412 6 22.80

ACDCT0370250

3 12.80

ACDCT0413 6 25.55

ACDCT0380300

3 16.70

ACDCT0414 6 31.75

ACDCT0415350

3 20.60

ACDCT0416 6 40.10

ACDCT0417400

3 25.55

ACDCT0418 6 48.45

Comflex Insulated

ACDCT0088150

3 24.85

ACDCT0399 6 42.25

ACDCT0089200

3 31.45

ACDCT0343 6 55.15

ACDCT0400250

3 35.65

ACDCT0344 6 63.45

ACDCT0401300

3 41.75

ACDCT0402 6 74.60

ACDCT0403350

3 48.45

ACDCT0404 6 87.35

ACDCT0405400

3 55.65

ACDCT0406 6 99.65

Note: 450 - 600 mm Diameters are available by special order

Comflex Ducting

• Fully complies to AS4254 & AS4508 & AS1530 Pt3 and NZ Bldg Code

• DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated, spring steel wire helix

• DUCT SLEEVE: Fire retardant 75 um black low density polyethylene and UV stabilised

• DUCT INSULATION: AS4508 Polyester R0.6 nominal 250 grams per mtr/sq 40 mm thick

• TEMPERATURE RANGE: Maximum: +80˚C Minimum: -10˚C

• COLOUR: Silver with black sleeve

Note: No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure

COMFLEX™ Nude

COMFLEX™ Insulated R0.6 (40 mm)

AC39

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DUCT FITTINGS

Branch Take-Off - PolyRealcoldStock No.

Metric Size System Price$ Excl. GST

ACDCT1439 100-100-100 35.75

“Y” Piece - PolyRealcoldStock No.

Metric Size System Price$ Excl. GST

Poly Nude - Non Insulated

ACDCT1233 150-150-150 20.60

ACDCT0379 200-150-150 20.60

ACDCT0471 250-200-200 22.25

ACDCT0717 300-250-250 28.55

ACDCT0718 350-300-300 44.60

ACDCT0813 400-350-300 60.05

Reducers - PolyRealcoldStock No.

Metric Size System Price$ Excl. GST

Poly Nude - Non Insulated

ACDCT2067 125-100 7.55

ACDCT2066 150-125 8.55

ACDCT0486 200-150 12.10

ACDCT0487 250-200 14.35

ACDCT0488 300-250 16.00

ACDCT0489 350-300 18.35

ACDCT0490 400-350 19.50

AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

ACDCT0808 Hanging Strap 25 mm x 50 m 7.45

N0185 Insulation Tape 48 mm x 30 m roll - self adhering PVC (light grade) 9.70

N0187 Insulation Tape 48 mm x 30 m roll - self adhering PVC (heavy grade) 17.00

N0402 Aluminium Duct Tape 51 mm x 45.72 m roll 18.05

N0404 Silver Duct Tape 51 mm x 54.86 m roll 18.05

• Manufactured from HDPE

• U.V. stabilised• Heavy duty,

robust• Smooth internal

lines• No sharp edges• Positive lock

duct tabs

• Poly - High Density Polyethylene (HDPE)

Duct Joiners - Galv & PolyRealcoldStock No.

Description System Price$ Excl. GST

ACDCT0059 150 mm Galv Duct Joiner 13.95

ACDCT0071 200 mm Galv Duct Joiner 15.45

ACDCT0339 250 mm Galv Duct Joiner 19.10

ACDCT0723 150 mm Poly Duct Joiner 6.05

ACDCT0724 200 mm Poly Duct Joiner 7.45

ACDCT0725 250 mm Poly Duct Joiner 8.45

ACDCT0726 300 mm Poly Duct Joiner 9.75

ACDCT0770 350 mm Poly Duct Joiner 13.40

ACDCT0771 400 mm Poly Duct Joiner 19.22

ACDCT0772 450 mm Poly Duct Joiner 22.90

Duct Fittings

AC40

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DIFFUSERS

CD2000 One Piece 4-Way DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT0792 225 x 225 POA

ACDCT0468 300 x 300 POA

ACDCT0793 375 x 375 POA

• Manufactured from v-zero fire rated ABS plastic. AS/NZ 1530.3

• Resistant to scratching and fading

• Minimises problems associated with cold bridging in high humidity areas

• Spring loaded fixing clips

• Poly neck adaptors and side entry cushion boxes - refer page AC42

Univent (Fixed Blade) Diffuser - Face OnlyRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT1022 225 x 225 33.50

ACDCT1019 300 x 300 36.90

ACDCT1023 375 x 375 37.20

• Manufactured from high impact polystyrene, resistant to scratching and fading

• Minimises problems associated with cold bridging in high humidity areas

• Quick fixing clips, no tools required

• Adjustable airflow patterns

• Poly neck adaptors and side entry cushion boxes - refer page AC42

Double Deflection Grille - Wall DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT2020 300 x 100 46.35

ACDCT2021 350 x 150 51.40

• Manufactured in high quality aluminium extrusion profiles, powder coated white

• Designed with nylon brushes for efficient, smooth operation

• Deflection blades are adjustable individually

• Standard 20mm blade spacing

• Suits poly boots DCT0714, DCT0715 - refer page AC42

MAXVENT® One Piece 4-Way DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT2007 225 x 225 41.20

ACDCT2008 300 x 300 62.35

ACDCT2009 375 x 375 84.60

• One piece pressed aluminium, powder coated white

• Removable core, no joints, smooth airflow

• Poly neck adaptors and side entry cushion boxes - refer page AC42

• Technical data available

Diffuser

AC41

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

DIFFUSERS

One Piece Plaque DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT2012 225 x 225 POA

ACDCT1516 300 x 300 POA

ACDCT2014 375 x 375 POA

• One piece pressed aluminium, powder coated white

• Removable core, no joints, smooth airflow

• Poly neck adaptors and side entry cushion boxes

• Technical data available

• 595 x 595mm “lay in” T-rail diffuser

MAXVENT® Cone Ceiling DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT1472 150 16.80

ACDCT1473 200 26.50

ACDCT1474 250 44.30

ACDCT1475 300 55.25

• Manufactured from ABS plastic• Spring loaded fixing clips• Resistant to scratching and fading• Positive lock duct tabs• Adjustable screw in centre cone

UNIJET “Jet Centre” Ceiling DiffuserRealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT0500 150 29.80

ACDCT0501 200 43.50

ACDCT0098 250 49.75

• Manufactured from V Zero fire rated ABS plastic AS/NZ 1530 pt 3• Spring loaded fixing clips• Adjustable ‘set and forget’ damper blade• Comes with damper blade adjustment tool• Resistant to scratching and fading• Positive lock duct tabs

Opposed Blade Damper (OBD)RealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT2016 225 x 225 POA

ACDCT2017 300 x 300 POA

ACDCT2018 375 x 375 POA

ACDCT2019 450 x 450 POA

• Manufactured in high quality aluminium extrusion profiles

• Designed with nylon bearings for efficient, smooth operation

• Clips onto one piece 4-Way aluminium diffusers

• Powder coated black

• Opposed blade damper design to ensure regulation of airflow

• Screw type opening mechanism

AC42

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

NECK ADAPTER

Neck Adapter - PolyRealcoldStock No.

Metric Size System Price$ Excl. GST

RealcoldStock No.

System Price$ Excl. GST

No Damper With Damper

ACDCT0681 225 x 225-150 12.10 - -

ACDCT0545 225 x 225-200 12.10 - -

ACDCT0497 300 x 300-250 14.35 ACDCT0498 20.85

ACDCT0509 300 x 300-300 14.35 ACDCT0499 20.85

ACDCT0547 375 x 375-250 16.00 - -

ACDCT0549 375 x 375-300 16.00 - -

ACDCT0553 375 x 375-350 16.00 - -

ACDCT0555 375 x 375-400 16.00 - -

• To convert 250 mm to 200 mm spigots use DCT0965

Stepped SpigotRealcoldStock No.

Metric Size System Price$ Excl. GST

No Damper

ACDCT1409 550 x 550/400/450 28.55

Convert 250mm SpigotsRealcoldStock No.

Metric Size System Price$ Excl. GST

ACDCT1142 250-150 11.05

ACDCT0965 250-200 11.05

• Poly Adaptor “Snaps-On” to plastic diffusers, no tools or fixing required• Manufactured from high impact polystyrene, positive lock duct tabs• Poly neck adaptors to suit Uni-Vents, CD 2000 and some aluminium diffusers

Cushion Side Entry Box - PolyRealcoldStock No.

Metric Size System Price$ Excl. GST

Poly Insulated

ACDCT1003 225 x 225-200 37.20

ACDCT1006 300 x 300 -200 45.75

ACDCT0972 300 x 300 - 250 45.75

• Manufactured from HDPE, fits poly and aluminium diffusers

Boots - FloorRealcoldStock No.

Metric Size System Price$ Excl. GST

Poly Insulated

ACDCT0714 300 x 100-150 17.35

ACDCT0715 350 x 150-200 29.70

• Manufactured from high density polyethylene• U.V. stabilized• Robust, heavy duty• Smooth internal lines • Complete with collar and damper• Positive lock duct tabs, nail holes pre punched

left: no Damper right: with Damper

Neck Adapter

AC43

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

EGGCRATE GRILLE

Eggcrate Grille - Fixed Core (ERG)RealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT1989 150 x 150 20.60

ACDCT2002 225 x 225 28.55

ACDCT2003 300 x 300 39.45

ACDCT2004 375 x 375 50.90

*ACDCT2005 550 x 550 98.90

*595 x 595 mm “lay in” T-rail grille

• Manufactured in high quality aluminium extrusion profiles

• Flush face finish

• Powder coated white

• Poly neck adaptors see page AC42

Eggcrate Grille - With Filter (ERHFG)RealcoldStock No.

Neck Adaptor Size System Price$ Excl. GST

ACDCT0962 300 x 300 129.00

ACDCT1257 375 x 375 133.00

*ACDCT0966 550 x 550 169.00

*595 x 595 mm “lay in” T-rail grille

• Manufactured in high quality aluminium extrusion profiles

• Hinged removable filters

• Flush face finish

• Powder coated white

• Filter media G2 rated

• Poly neck adaptors see page AC42

Eggcrate Grille

AC44

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

WALL / CEILING FANS / GRILLS

MAXVENT® - 150 mm Wall / Ceiling FanRealcoldStock No.

Description System Price$ Excl. GST

ACFAN0007 150mm Wall / Ceiling Fan 64 l/s Standard 96.10

MANROSE® Wall / Ceiling Grille with Duct SpigotRealcoldStock No.

Metric Size Colour System Price$ Excl. GST

Fixed Louvre

ACDCT0025 100 White 10.00

ACDCT0041 120 White 14.45

ACDCT0063 150 White 22.80

ACDCT0340 200 White 56.55

MANROSE® Weatherproof CowlRealcoldStock No.

Metric Size Colour System Price$ Excl. GST

ACDCT0018 100 White 14.45

ACDCT1031 150 White 42.65

• Used where adverse weather conditions are experienced

AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

ACFAN0372 Delay Timer 28.85

• Suits fans 20-200W

• Suitable for retrofit

• Switches off after 7mins

• Standard grille with some weather protection

• Removable insert for ease of installation & cleaning

Wall / Ceiling Fans / Grills

AC45

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

ROOF VENTILATION

Roof Fan Kits with Dektite & HDPE TubeRealcoldStock No.

Metric Size Fan Type Litres Per Second Air System Price$ Excl. GST

ACFAN0530 150 Ctr’fgl 130 l/s Extract 394.00

ACFAN0532 150 Axial 80 l/s Extract 280.00

ACFAN0534 150 Axial 80 l/s Supply 280.00

• Fan incorporated within the cowl

• Aluminium cowl construction

• Pleasing aesthetics

• High quality for longevity of operation

• Electrical connection can be made inside or outside roof space

• Dektite included (for metal based roofs), all fittings supplied

• Optional lead dektite available to order

NB: Lead Dektite (DCT0190) required for

concrete tile roofs

NB: Lead Dektite (DCT0190) required for

concrete tile roofs

Roof Fan & Cowls

Roof Cowl Kits with Dektite & HDPE TubeRealcoldStock No.

Metric Size Description System Price$ Excl. GST

ACDCT0172 150 General Purpose Kit 122.00

• General purpose cowl included

• 0.5m HDPE Tube included

• Dektite included (for metal based roofs)

• All fittings supplied

• Optional lead Dektite available to order

• Refer to page AC35 for Roof Penetration Kit - compliant with NZ Metal Roofing Code of Practise

Roof Ventilation

AC46

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

IN LINE FANS

High Performance Centrifugal In-Line FansRealcoldStock No.

Metric Size Performance dBA 3m* Max. Pressure (Pa) System Price$ Excl. GST

ACFAN0358 250 280 l/s, 1008 m3/hr 46 500 418.00

* dBA @ 3 metres - sound pressure based on the high speed for each fan

• Manufactured from V Zero fire rated ABS plastic

• Centrifugal fan design, quality external rotor ball bearing motor

• Motor wired to junction box

• Fan mounting brackets available

• Continuously rated motor

• Pressure curves - refer page AC52

MAXVENT® High Performance Axial In-Line FansRealcoldStock No.

Metric Size Performance dBA 3m* Max. Pressure (Pa) System Price$ Excl. GST

ACFAN0085 150 89 l/s, 320 m3/hr 46 135 126.00

* dBA @ 3 metres - sound pressure based on the high speed for each fan

• Quality ball bearing motor

• Integral mounting

• High performance axial fan

• Continuously rated motor

• Technical data - refer page AC52

MIXFLO™ Mixed Flow In-Line FansRealcoldStock No.

Metric Size Model Max. Airflow (l/s)

Max. Pressure (Pa)

dBA 3m* System Price$ Excl. GST

ACFAN1004 100 MF100 69 200 40 182.00

53 120

ACFAN1005 125 MF125 89 230 43 201.00

72 160

ACFAN1006 150 MF150 156 360 47 225.00

117 320

ACFAN1007 200 MF200 253 300 48 274.00

228 225

200 150

* dBA @ 3 metres - sound pressure based on the high speed for each fan

• Designed for applications that require high air flows with relative low noise

• High quality ball bearing, long life motors, continuously rated and warranted for a minimum of 30,000 hours or 4 years

• Can be easily installed in series to increase pressure

• 2 speed fan settings for 100mm, 125mm and 150mm models and 3 speed fan settings for the 200mm model

• Brackets are supplied with the fan for ease of installation

• Fan assembly can be easily removed from rigid ducting installations for ease of cleaning and maintenance.

• Double Insulation - no earth required

• Technical data - refer pages AC52

In Line Fans

AC47

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

IN LINE FANS - TECHNICAL DATA

Fan Dimensions (mm)Model A B* C D E F G

MF100 98 182 262 100 100 168 21

MF125 122 182 262 100 100 168 60

MF150 147 209 293 130 115 192 60

MF200 197 244 354 142 140 230 52

*Measured with junction box on side (junction box height of 35mm)

Technical SpecificationModel Order Code Size (mm) RPM Wattage Max.

Airflow (l/s)Max. Pressure (Pa)

Lp dBA 3m* kg IP Rating Max. Operating Temp °C

MF100 FAN1004 1002300 40 250 200

40 2.1 X4 451700 18 190 120

MF125 FAN1005 1252300 40 320 230

43 2.1 X4 451700 18 260 160

MF150 FAN1006 1502700 70 560 360

47 3.2 X4 452000 60 420 320

MF200 FAN1007 200

2700 85 910 300

48 4.5 X4 452350 60 820 225

2000 45 720 150

* dBA @ 3 metres - sound pressure based on the high speed for each fan

Sound Power Levels (high speed)Model Sound Power Levels LW (dBA) - Octave band centre frequency in Hz LwA dBA

125 250 500 1000 2000 4000 8000

MF100 50 56 58 58 52 47 37 61

MF125 52 59 60 60 56 49 41 63.5

MF150 58 66 65 63 62 54 46 67.5

MF200 65 69 64 63 62 60 48 69

AC48

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

IN LINE FANS - FAN CURVES

MIXFLO™ Mixed Flow In-Line Fans - Performance Curve

AC49

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

IN LINE FANS - TECHNICAL DATA

High Performance Centrifugal In-Line Fans ACFAN0358 Technical Data

Axial In-Line Performance Curves

MAXVENT™ High Performance Axial In-Line Fans ACFAN0085 Technical Data

Hyper150 High Performance Axial FanNoise Level dBA @ 3m 46

Frequency Hz 50/60

Power Input W 38

Current A 0.38

Speed RPM 2650

Voltage V 240

Weight kg 1.3

Max. Ambient Temp °C 70

Axial In-Line Fan Dimensions

AC50

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

TRANSFER FANS

MAXVENT™ Heat Transfer SystemRealcoldStock No.

Description System Price$ Excl. GST

ACFAN0475 150 mm Maxvent™ (1 Room) Heat Transfer 290.00

ACFAN0542 150 mm Maxvent™ (2 Room) Heat Transfer Plus 540.00

ACFAN0543 200 mm Maxvent™ (3 Room) Heat Transfer 655.00

The Maxvent™ Heat Transfer system utilizes otherwise wasted heat by distributing excess heat throughout the home. The heat transfer system works by slowly drawing air from the heated room and transferring it to a remote room via the ducting and fan in the ceiling space.

Benefits

• The Heat Transfer system increases home heating efficiency by transferring previously ‘wasted’ heat to other parts of the home.

• High quality, durable components are used, including high performance fans and thermostat controller.

• Maxvent™ Heat Transfer is a complete kit incorporating all of the components needed for a standard job.

Transfer Fans

AC51

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING WARRANTY INFORMATION

The warranty is applicable to Gree products purchased from Realcold Limited and installed in New Zealand. Mitsubishi Heavy Industries warranty is held by Mitsubishi Heavy Indus-tries Air-Conditioners Australia Pty Ltd.

Realcold Limited (herein called the company) warrants the prod-ucts are free of defects from manufacture. Any proven defect will be rectified by the company, or an authorized service agent, free of charge within the appropriate time limits and subject to the conditions set out on the New Zealand warranty card supplied with the air conditioner.

5 YEAR WARRANTY Residential Installation

2 YEAR WARRANTY Commercial Installation (See notes below)

Multi Inverter Air Conditioners (only 24 month warranty applies for process cooling and commercial applications).

Split Type Hi-wall Air Conditioners (only 24 month warranty ap-plies for process cooling and commercial applications).

Window Air Conditioners (only 24 month warranty applies for process cooling and commercial applications).

Heat Recovery Ventilators (only 24 month warranty applies for process cooling and commercial applications).

Notes

1 In home service available in major metropolitan areas or within 30 km from service agents only. Consumers in ar-eas other than the above will require prior authorization from the company for any mileage and travel charges.

2 Multi, Split and / or Ducted Air Conditioners must be in-stalled by a qualified installer.

3 Regular maintenance must be carried out at intervals not exceeding one year and the maintenance record com-pleted on the retained warranty card as each service occurs.

4 The removable portion of the warranty card must be fully completed and returned to the company to register your warranty.

Contractor / Installer responsibilities:

• Install the air conditioner as per the manufacturer’s instructions.

• Installation is to be done by a qualified tradesperson following best trade practices.

• Theequipmentmustbesafelyaccessibleusingathreemetre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty.

• Explaintheoperationtotheowner/occupier.

• Ensuretheremovableportionofthewarrantycardhasbeen completed and returned to Realcold Limited.

• Ensurethattheowner/occupierretaintheremainderofthe warranty card.

• Explaintotheowner/occupierthatthewarrantywillbevoid unless the unit is serviced annually.

Before making a warranty claim please consider the following:

• Checkandresetthepowersupply.

• Check theairconditioner’sremotecontrolsettings (payattention to timers and mode operation).

• Ensurefiltersanddrainsareclear.

• Checkeitherunitforobstructionsreducingairflow.

• Arethedoorsorwindowsopen,orarethereextrasources of heat in the room?

• Checktherefrigerantcharge.

To make a warranty claim:

• Ensurealldetailsonthewarrantycardhavebeencom-pleted and your warranty has been registered.

• Astheinstalleryouwillbeexpectedtoactastheserviceagent.

• CallyourlocalRealcoldbranchandquotethemodel,se-rial number and the warranty card number to obtain a warranty registration card. You may be asked to provide proof of purchase to establish warranty. (This authoriza-tion number is for administration purposes only and the company accepts no liability with the issue of this num-ber. Failure to obtain this number may delay settlement of your warranty).

• Return all damaged or defective parts ormaterials toyour local Realcold branch. Please fill in a goods return form, quoting you warranty authorization number. These parts are required for testing purposes.

Notes

Unless components are found to be defective and then ex-changed or repaired it is deemed by Realcold Limited that this was not covered under warranty and there will be a charge for non-warranty calls.

GREE AIR CONDITIONINGWARRANTY INFORMATION

AC52

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING WARRANTY INFORMATION

MHI AIR CONDITIONING WARRANTY INFORMATION

The Warranty on all Mitsubishi Heavy Industry product is covered by Mitsubishi Heavy Industries Air-Conditioners Australia Pty Ltd (MHI) and its New Zealand subsidiary. This warranty covers all MHI product purchased from Realcold Ltd and installed in New Zealand.

Please see MHI for their full warranty terms and conditions.

5 YEAR WARRANTY All Products Excluding the KX Range (service - see notes below)

5 YEAR WARRANTY KX Range Residential Installations (service - see notes below)

3 YEAR WARRANTY KX Range Commercial Installations (service - see notes below)

Contractor/Installer responsibilities:

• Install the air conditioner as per themanufacturer’s instructions

• Installation is to be done by a qualified tradesperson following best trade practices

• Theequipmentmustbesafelyaccessibleusingathreemetre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty

• Explaintheoperationtotheowner/occupier

• Explaintotheowner/occupierthatthewarrantywillbevoid unless the unit is serviced annually

Before making a warranty claim please consider the following:

• Checkandresetthepowersupply

• Check theairconditioner’sremotecontrolsettings (payattention to timers and mode operation)

• EnsureDrainsandFiltersareclear

• Checkeitherunitforobstructionsreducingairflow

• Arethedoorsorwindowsopen,orarethereextrasourc-es of heat in the room?

• ChecktheRefrigerantCharge

To make a warranty claim:

• YoumustbeaMHIserviceagenttomakeaclaim

• CallyourlocalbranchofRealcoldquotingthemodelandserial number plus a full description of the fault

• Pleasecheckthesystemforfaultcodes

• Pleasecheckthegaschargepriortocalling

• Youmaybeaskedtoprovideproofofpurchasetoestab-lish warranty.

• Realcoldwillassistwithtechnicalsupporttoestablishthefault and a course of action to remedy the fault

• Astheinstalleryouwillbeexpectedtoactastheserviceagent

• Shouldthefaultbeacceptedasawarrantythesupplyofspare parts and the cost of any labour will be met by MHI in accordance with their terms and conditions

Note

Unless components are found to be defective and then ex-changed or repaired it is deemed by MHI that this was not cov-ered under warranty and there will be a charge for non-war-ranty calls

AC53

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Air

Con

ditio

ning

AIR CONDITIONING WARRANTY INFORMATION

Air Conditioning WarrantyCoolbreeze

12 Months Parts Only on Evaporative Coolers

Eclipse

12 Months Parts Only on Air Curtain Models

Gree

5 Years Parts & Labour on all Models (Residential Installations Only)

2 Years Parts & Labour on all Models (Commercial Installations Only)

Refer to page AC51 for exceptions to the above

Mitsubishi (Warranty provided by MHI)

5 Years Parts & Labour on all Models (Except KX)

5 Years Parts & Labour on KX Range (Residential Installations Only)

3 Years Parts & Labour on KX Range (Commercial Installations Only)

See MHI for full details

Aspen Pumps

12 Months Parts Only on all Condensate Pumps

Note: The terms & conditions of warranty do not affect your rights under act 1, 2, 3.

AIR CONDITIONINGWARRANTY INFORMATION

Refrigera

tion

Components

Com

pone

nts

ComponentsAccumulators CA60

Brazing CB61

Brazing Torches CB62

Chemicals CC63Coil and Filter Cleaners CC63Thread Sealants CC63Miscellaneous Cleaners/ Disinfectants CC64Liquid Leak Detectors CC65

Compressors - Sealed Reciprocating CC66L’Unite R404a Medium Temp CC66L’Unite R404a Low Temp CC66L’Unite R134a Low Temp CC67L’Unite R134a Medium Temp CC67L’Unite Sealed Air Conditioning CC68L’Unite Sealed Compressors CC69L’Unite Sealed Rotary Compressors - Vertical CC72L’Unite Sealed CC73Solid State Relays CC74

Compressors - Copeland Scroll™ CC75Copeland Scroll™ Compressors - Introduction CC75Copeland Scroll™ - R22 Medium Temp CC76Copeland Scroll™ Compressors Accessories CC77

Compressors - Semi Sealed Reciprocating CC80Capacity Control CC82Accessories CC82

Compressors - Semi-Hermetic Screw CC83

Defrost Controls CD88Defrost Safety Thermostats CD89Defrost Heat Tape CD89Condensate Pans CD89

Driers CD90Sporlan Driers - Flare CD90Suction Line CD91Refillable Shells - Liquid Line CD92Refillable Shells - Suction Line CD92Directional CD93

Discharge Line Mufflers CD94

Electronic Controls CE95Refrigeration Controls CE95Accessories CE95Control Panels CE96

Fans CF97Fan Motors CF97Accessories CF97Fan Motor Assembly CF98Fan Blades CF99

Fittings CF100Brass Fittings - Flare CF100Copper Fittings CF102Fittings & Fasteners CF103Thermoplastic - Nylon CF105

Refrigera

tion

Components

Com

pone

nts

Components (continued)

Evaporator Mounting Kits - Nylon CF106Insulclamp CF107Studding Clip CF107BBJ Pipe Fittings CF107Locksets CF108Hinges CF108Style Spares - Efco CF108Accessories - Efco CF108Heat Exchangers CH109

Insulation CI110Tube Insulation CI110Sheet Insulation CI1111 Metre Adhesive Insulation CI111Roll Insulation CI111Insulation Tape CI112Accessories, Sealing, Jointing Compounds CI113

Lubricants CL114

OIL CONTROL SYSTEMS CO116Trax Oil Control Systems CO116Oil Reservoir And Accessories CO116Oil Separators CO118

PRESSURE CONTROLS CP119Dual Pressure Controls CP119Low Pressure Controls CP119High Pressure Controls CP119Differential Pressure Controls CP119Oil Protection Controls CP120Saginomiya Flow Switches CP120Pressure Control Accessories CP120Pressure Control Hoses CP120Pressure Controls - CB Series CP121Small Pressure Controls - Type ACB, LCB CP121

REFRIGERANT CR122

RECEIVERS CR124Vertical Receivers CR124Horizontal Receivers CR125

SIGHT GLASSES CS126

TEST EQUIPMENT CT127Service Manifold Sets CT127Charging Hoses CT127Gauges CT128Accessories CT128Couplers CT128Imperial Kwik - Couplers CT128Recovery System CT129Recovery Cylinders CT129Vacuum Pumps CT129

TOOLS CT130Electronic Vacuum Gauge CT130Charging Equipment CT130Leak Detectors CT130Mastercool Tools CT130Tube Cutters CT130

Refrigera

tion

Components

Com

pone

nts

Components (continued)

Tube Deburring Tool CT130Tube Expander Kit CT130Ratchet Wrenches CT130Tube Cutter Spares CT131Flaring & Swaging Tools CT131Tube Benders (lever type) CT132Bending Springs CT132Allen Key (hex key) CT132Pinch Off Tool CT133Oil Pump CT133Oil Injector CT133Fin Combs CT133Inspection Mirrors CT133Miscellaneous Tools CT134Temperature Test Equipment CT134Refractometers CT134Thermometers CT134

THERMOSTATS CT135

TUBE CT137

VALVES CV139Flica Orifices CV139Flica Thermostatic Expansion Type CV139Sporlan Q-Series Thermostatic Expansion Valves CV140Sporlan Orifices CV140Sporlan Thermostatic Elements CV140Sporlan Accessories CV140Sporlan J8 Thermostatic Expansion Valves CV141Cross Reference Table CV142Sporlan S and O-Series Valves CV143Sporlan TX Valve Replacement Heads CV143Sporlan Solenoid Valves (less coil) CV144Sporlan Solenoid Coils CV144Parker Hannifin SpA Solenoid Valves (complete with coils) CV145Parker Hannifin SpA Solenoid Valve Spares (replacement solenoid coils) CV145Pressure Regulators CV146Sporlan CDS Valves CV147Sporlan Hot Gas Bypass Valves CV147Sporlan Co2 Product Range CV147Mueller Ball Valves (two way) CV148Mueller Liquid Receiver Valves CV148Mueller Rotalock Valves CV148Mueller Hand Shut-Off Valves (packless line valves) CV149Mueller Pressure Relief Valves CV149Three Way Hand Shut-Off Valves CV149Check Valves - Refrigerants HFC & HCFC CV150Gaskets CV150Line Tap Valves CV151Schrader Valves / Access Ports CV151

VIBRATION ELIMINATORS CV152

Spares Spares153

COMPRESSOR AND CONDENSING UNIT WARRANTY CX167

CA60

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

ACCUMULATORS

Accumulators - Suction LineRealcoldStock No.

Model DescriptionkW Cap at Evap. Temp. -6°C

System Price$ Excl. GST

Size Connection R22 R404a/R507c

F0804 Virginia Accumulator 1/2" 1/2" ODS Vertical 4.6 4.8 53.09

F0805 Virginia Accumulator 5/8" 5/8" ODS Vertical 6.9 7.2 86.70

F0806 Virginia Accumulator 3/4" 3/4" ODS Vertical 9.2 9.6 86.70

F0807 Virginia Accumulator 7/8" 7/8" ODS Vertical 16.7 17.5 99.81

F0809 Virginia Accumulator 1.1/8" 1.1/8" ODS Vertical 27.0 28.3 155.04

F0811 Virginia Accumulator 1.3/8" 1.3/8" ODS Vertical 43.1 45.2 210.12

F0813 Virginia Accumulator 1.5/8" 1.5/8" ODS Vertical 65.3 68.4 252.96

F0121 Carly Vertical Accumulator 2.1/8” LCY 1817 S/MMS 125 130 1,213.80

F0125 Carly Vertical Accumulator 3.1/8” LCY 5025S 288 300 2,007.36

* These accumulators should not be used below -18°C without supplementary heating to ensure oil return - see information on Heater Elements below.

Factors for Determining Capacity

Evap. Temp. -18°C -30°C

Factor .68 .41

Note: To find kW capacity for the other evaporator temperatures, multiply factor X rating listed at -6C

Selection of a suction line accumulator should be made on the basis of the following capabilities:

• The accumulator should have an adequate liquid holding capacity - normally not less than 50% of the system charge.

• The accumulator should perform efficiently without excessive pressure drop to the system.

• The accumulator should return liquid at the proper rate and under a range of conditions of load.

• The selection of the suction line accumulator should not be based on line size, but on its ability to perform well within the limits described above. Consequently the suction line accumulator will not necessarily have the same connection size as the compressor suction line.

Heater Elements To Suit AccumulatorsElements must be used when operating under -18°C. The element adds heat to oil separators in order to prevent migration of refrigerant to the vessel during the off cycles of the compressor. Heater elements also add heat to suction line accumulators, to keep the oil warm, permitting oil return to the compressor on low temperature applications.

• For Heater Elements please refer to page CO118

Accumulator Dimensions - Suction LineRealcoldStock No.

Model Diameter (mm)

Overall Height (mm)

Height of Vessel (mm)

Fitting Size (mm)

Fitting Separating Centre - Centre (mm)

F0804 Accumulator 1/2" 76 209 184 1/2" 13 mm 41

F0805 Accumulator 5/8" 76 314 292 5/8" 16 mm 41

F0806 Accumulator 3/4" 76 321 292 3/4" 19 mm 41

F0807 Accumulator 7/8" 127 244 216 7/8" 22 mm 70

F0809 Accumulator 1.1/8" 127 376 340 1.1/8" 29 mm 70

F0811 Accumulator 1.3/8" 127 468 430 1.3/8" 35 mm 70

F0813 Accumulator 1.5/8" 152 556 514 1.5/8" 41 mm 75

F0121 LCY 1817 S/MMS 219 732 733 2.1/8 54 mm 114

F0125 LCY 5025 S 324 900 900 3.1/8 80 mm 155

Accumulator

F0084

Carly Accumulator

CB61

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

Accumulator Dimensions - Suction LineRealcoldStock No.

Model Diameter (mm)

Overall Height (mm)

Height of Vessel (mm)

Fitting Size (mm)

Fitting Separating Centre - Centre (mm)

F0804 Accumulator 1/2" 76 209 184 1/2" 13 mm 41

F0805 Accumulator 5/8" 76 314 292 5/8" 16 mm 41

F0806 Accumulator 3/4" 76 321 292 3/4" 19 mm 41

F0807 Accumulator 7/8" 127 244 216 7/8" 22 mm 70

F0809 Accumulator 1.1/8" 127 376 340 1.1/8" 29 mm 70

F0811 Accumulator 1.3/8" 127 468 430 1.3/8" 35 mm 70

F0813 Accumulator 1.5/8" 152 556 514 1.5/8" 41 mm 75

F0121 LCY 1817 S/MMS 219 732 733 2.1/8 54 mm 114

F0125 LCY 5025 S 324 900 900 3.1/8 80 mm 155

BRAZING

Brazing Alloy (Silver)RealcoldStock No.

Type Tip Colour Diameter x Length (mm)

Sold Per System Price$ Excl. GST

N0525 5% SBA Silver 2.5 x 750 Per Kilo 198.00

N0525A 5% SBA Silver 2.5 x 750 Per Stick 6.58

N1515 15% SBA Tan 1.5 x 750 Per Kilo 550.00

N1515A 15% SBA Tan 1.5 x 750 Per Stick 5.98

N1525 15% SBA Tan 2.5 x 750 Per Kilo 550.00

N1525A 15% SBA Tan 2.5 x 750 Per Stick 13.80

N1530 15% SBA Tan 3.0 x 750 Per Kilo 550.00

N1530A 15% SBA Tan 3.0 x 750 Per Stick 21.98

N3415 34% SBA Green 1.5 x 750 Per Kilo POA

N3415A 34% SBA Green 1.5 x 750 Per Stick POA

N5515 55% SBA Dark Green 1.5 x 750 Per Kilo POA

N5515A 55% SBA Dark Green 1.5 x 750 Per Stick POA

N5530 55% SBA Dark Green 3.0 x 750 Per Kilo POA

N5530A 55% SBA Dark Green 3.0 x 750 Per Stick POA

N5020 General Purpose Flux for Silver Brazing Alloy 250gm Pot 35.75

• 5% Silver (Silver Tip) Suitable for copper to copper and copper alloys. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.

• 15% Silver (Tan Tip) Suitable for copper to copper and copper alloys, giving excellent ductility for high stressed joints. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.

• 34% Silver (Green) GP alloy for general engineering metals giving excellent fluidity with excellent gap filling qualities. Flux should be used. Cadmium free.

• 55% Silver (Dark Green Tip) Excellent alloy, giving high strength with excellent capillary action. Good ability to fill fine gaps. Cadmium free.

• Realcold recomend the use of General Purpose Flux, N5020, when brazing non-ferrous metals.

Brazing AccessoriesRealcoldStock No.

Description Sold Per System Price$ Excl. GST

N5022 La-Co Aluminium Repair Kit Complete with flux paste, (for easy soldering of aluminium to copper).

Kit 49.42

N0003 MA-Line Sand Cloth 1.1/2” 9 metre 11.62

N0005 MA-Line Sand Cloth 1.1/2” 22 metre 28.17

N0007 MA-Line Mesh Cloth 1.1/2” 45 metre 16.01

N0009 MA-Line Open Mesh Cloth 1.1/2” 9 metre 28.71

N0010 Emery Tape 80 grit 50 metre Roll 67.32

N0015 Emery Tape 180 grit 50 metre Roll 79.46

N5022 T0119

N0010

CB62

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

BRAZING TORCHES

Bernzomatic Self-Igniting Brazing TorchesRealcoldStock No.

Description System Price$ Excl. GST

N6006 BERNZOMATIC Self-Igniting Brazing Torch

A simple press of the piezo igniter gives instant flame for brazing. The high performance pressure regulator and swirl flame allows higher temperatures than conventional torches. Superior performance in cold weather.

116.74

N6010 Brazing Turbo Set 200 Excl. Gas

CB66 Brazing Torch Description: A light weight welding and brazing system with disposable gas cylinder’s. Each kit contains:

• MetalStoragecarrier

• OxygenpressurereducerswithHPgaugeandflashbackarrestors

• MappPropressurereducerwithLPgaugeandflashbackarrestors

• 2mhoseswithconnections

• Handpiecewith160Inozzle

• 4additionalnozzles63–100–250–315I

• Protectivegoggles

• Multi-purposespanner

• Flintlighter

• 2xWeldingRod

500.00

N6050 Gas Canister (Disposable) 30.90

N6011 1L Oxygen Cylinder 95.00

Some helpful hints on using your Bernzomatic:

• NOTE - USE only IN WELL VENTILATED AREAS

• DO NOT ADJUST THE FLAME SO LOW THAT THE STEEL BURNER TIP BECOMES RED HOT OR DAMAGE TO THE TIP MAY RESULT.

Q. Why does my torch head break at the air holes?

A. In order to ensure that the cylinder does not break or explode if the torch is accidentally dropped or abused, BernzOmatic torches are designed to break safely at the air holes.

Q. Why will my torch not stay lit when tipped upside down?

A. When a non regulated brass torch is tipped upside down, the liquid propane in the torch works its way through the torch and blows out the flame

Q. Why in cold weather do I only get a small flame out of my torch?

A. The size of the torch flame varies with the pressure in the gas cylinder. When it is very cold there is only a small amount of gas pressure in the cylinder.

Q. Why is my torch hard to light?

A. Most torches light better when the valve is just cracked open, and there is a small gas flow.

N6010 Brazing Turbo Set 200

CC63

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

CHEMICALS

Coil and Filter CleanersFoam Brite Condenser Coil Cleaner - Non Acidic

Penetrating non-acidic foaming action lifts and pushes contaminants and oxide off coils, including stubborn grease, tars and dirt, so that they can be rinsed away with water. Works in less than 5 minutes.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0707 Greenleaf Foam Brite 1L spray 22.08

N0708 Greenleaf Foam Brite 5L 55.18

N0726 Greenleaf Non Caustic 5L 61.51

Evaporator Coil Cleaner - Self Rinsing

A clean evaporator is the first step in ensuring maximum compressor efficiency. Greenleaf Evaporator Coil Cleaner is a safe, biodegradable alkaline self rinsing coil cleaner. It has a safe, non acidic formula which can be used indoors. NZFSA Approved C101.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0727 Greenleaf Evaporator Coil Cleaner 1L spray 22.08

N0728 Greenleaf Evaporator Coil Cleaner 5L 55.18

N0729 Greenleaf Evaporator Coil Cleaner 20L 174.42

Clean-N-Safe ™

A non-acid, non-caustic, non-corrosive evaporator and condenser coil cleaner. It is completely biodegradable and is safe for use around people, animals, aquatic life, and vegetation, USDA-H1.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0720 Clean-N-Safe ™ 3.8L 59.36

N0721 Clean-N-Safe ™ 568gm Aerosol spray can

27.34

CF-20 Internal Coil System Cleaner & Acid Neutraliser

Replaces R11 as a flushing agent. Environmentally safe, biodegradable interior coil cleaner for refrigeration and air conditioning systems. To clean interior coils after a compressor failure or burn-out and to remove mineral oil residue in preparation for retrofitting.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0820 Internal System Cleaner CF20 1L spray 123.42

® ™ Registered trade mark of The Rectorseal Corporation.

Thread SealantsRealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0058 Nylog Blue 30ml POE Oil Sys. each 20.10

N0059 Nylog Red 30ml Mineral Oil Sys. each 20.10

N0063 Leak-Lock Tube 1oz tube 9.80

N0065 Leak-Lock Brush Top Plastic Jar 4oz tube 21.15

N0069 Teflon Thread Seal Tape 12 mm x 10m roll 3.00

Rectorseal

CC64

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

CHEMICALS

Miscellaneous Cleaners/ Disinfectants Eucalyptus All Purpose Cleaner & Degreaser

A powerful all purpose cleaner & degreaser, with the added cleaning, deodorising and disinfecting power of natural eucalyptus oil. Sold as a concentrate. MAF approval C32.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0752 Greenleaf All Purpose Cleaner 1L spray 22.65

N0753 Greenleaf All Purpose Cleaner 5L 62.33

N0754 Greenleaf All Purpose Cleaner 20L 222.77

Ice Machine Cleaner - Nickel Safe

Biodegradable cleaner, specially formulated for removing scale deposits from ice machines with nickel or tin plated evaporators. Easy to use whilst providing a thoroughly clean machine. Sold as a concentrate.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0712 Greenleaf Ice Machine Cleaner 1L 19.87

N0713 Greenleaf Ice Machine Cleaner 5L 55.74

KO Dirt Blaster

High pressure cleaner- degreaser for filters, motors, relays, small condensers, etc. Blasts off dirt and grease without a rinse.Quick drying, electrically safe.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0734 Stewart Hall KO Dirt Blaster - Aerosol 568gm 33.10

Coil And Duct Disinfectant

An all in one spray that disinfects all surfaces, whilst also deodorising. A blend of Deodoriser and EPA Registered Hospital Grade QUAT Disinfectant kills a wide range of pathogens and sodium hypochlorite to kill legionaella pneumophila, and most air borne pneumonia bacteria.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0746 Greenleaf Coil & Duct Disinfectant 1L spray 19.33

N0747 Greenleaf Coil & Duct Disinfectant 5L 48.57

Germicidal cleaner, deodorizer and disinfectant for ducts, coils, air filtering equipment and most other hard surfaces. Kills disease causing bacteria, as well as mould, fungi, and mildew. Helps cure bad odours, and Sick Building Syndrome reactions of sensitive people.

N0748 Greenleaf Air Filter Cleaner 1L 23.18

N0749 Greenleaf Air Filter Cleaner 5L 56.76

Actabs

Prevent drain pan overflow and odours. Patented dispenser avoids monthly applications. Lasts about 5 months. Actabs are placed in the drain pan.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0703 Stewart Hall Actabs Self-dispensing pack of 6 20.45

N0704 Stewart Hall Actabs JR 400g Bottle - approx. 200 tabs 106.46

CC65

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

CHEMICALS

Miscellaneous ChemicalsAcid-Away®

A unique chemical treatment for use in air conditioning and refrigeration systems that have experienced a burn out or operating systems that are showing a build-up of acid content. May be used in hermetic or semi hermetic compressors that operate with standard CFC or HCFC refrigerants using mineral and alkylbenzene type refrigeration oils.

Acid-Away® has been tested in accordance with ANSI/ ASHRAE standards 86-1983 and 97-1989, along with various ASTM standards.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0800 Acid-Away® for Mineral/ Alkylbenzene Oils

(not suitable for polyolester oils).

118ml bottle (4oz) 76.68

N0808 Acid-Away® for Polyolester Oils 118ml bottle (4oz) 83.86

Acid Test Kits

Oil should be tested immediately after removal from unit.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

T0117 ETK Refrigeration Oil Acid Test Kit - Polyolester Oil 118ml bottle (4oz) 31.06

T0118 TKO Refrigeration Oil Acid Test Kit 118ml bottle (4oz) 24.31

Coil Protectant

Designed to protect coils and cabinets from corrosion.

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

N0062 Blue Coil Guard 600ml 83.33

Liquid Leak DetectorsBig Blu Leak Reactant

RealcoldStock No.

Description Pack Size System Price$ Excl. GST

T0440 Big Blu leak Reactant Complete With Spray Applicator 0.947 L 20.45

T0442 Big Blue Leak Reactant 3.785 L 77.22

® ™ Registered trade mark of The Rectorseal Corporation.Visit www.rectorseal.com and www.greenleaf.co.nz for additional product information and MSDS Data Sheets.

ACTABS

Actabs with its EPA registered biocide eliminates or prevents most blockages in air conditioning and refrigeration drain lines due to the buildup of bacterial slime, rust, scale, sludge, air bourne dust, silty and other solids.

• Unique automatic metering dispenser

• EPA Registered

• Prevents Costly Water Overflow Damage

• Eliminates Bacteria Casused Bad Odours

• Can be used in Computer Rooms

CC66

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED RECIPROCATING

L’Unite R404a Medium TempColumn Key: D = Displacement, OC = Oil Charge, FIG = Picture # Control = Cap/TEV for all models listed FIG = Picture # on page CC72

RealcoldStock No.

Model Fig. Nom. Hp

Appl. Watts H (mm) Displ. (cm3)

OC (L) System Price$ Excl. GST

-15°C -10°C -5°C 0°C +7.2°C +15°C

Domestic - Commercial 220/240 Volt 50 Hz Single Phase

C7010 AEZ4425Z Fig 1 1/5 HT 198 263 341 432 587 787 186 4.50 .45 255.00

C7012 AEZ4430Z Fig 1 1/4 HT 258 346 441 550 741 1010 186 5.70 .45 306.00

C7014 AEZ4440Z Fig 1 1/3 HTW 357 462 590 743 1004 1342 199 7.55 .45 410.04

C7016 CAE9450Z Fig 2 3/7 HTW 434 567 731 927 1270 1729 212 9.40 .45 459.00

C7020 CAE9460Z Fig 2 1/2 HTW 500 663 857 1092 1517 2139 212 11.30 .45 467.16

C7021 CAE9470Z Fig 2 1/2 HTW 613 803 1031 1305 1804 2535 215 13.30 .45 475.32

C7022 CAJ9480Z Fig 3 5/8 HTW 690 911 1173 1487 2060 2903 271 15.20 .89 732.36

C7030 CAJ9510Z Fig 3 1.0 HTW 878 1151 1476 1866 2579 3628 282 18.30 .89 767.04

C7032 CAJ9513Z Fig 3 1.1/8 HTW 984 1349 1770 2263 3145 4418 282 24.20 .89 804.78

C7036 CAJ4517Z Fig 3 1.1/4 HT 1191 1614 2104 2677 3697 5158 282 25.95 .89 828.24

C7038 CAJ4519Z Fig 3 1.1/2 HT 1592 2121 2739 3468 4780 6683 282 34.45 .89 879.24

*C7040 FH4524Z Fig 4 2.0 HT 1587 2290 3110 4073 5736 8204 354 43.50 1.33 1,095.48

*C7042 FH4531Z Fig 4 2.1/2 HT 2165 3029 4029 5205 7412 10325 370 56.65 1.33 1,179.12*C7040 and *C7042 are available both single and three phase - please state when ordering.

Commercial 400 Volt 50 Hz Three Phase

*C7048 TFH4522Z Fig 4 1.3/4 HT 1322 1924 2640 3501 5066 7312 354 39.95 1.33 986.34

*C7050 TFH4524Z Fig 4 2.0 HT 1587 2290 3110 4073 5736 8204 354 43.50 1.33 1,010.82

*C7054 TFH4531Z Fig 4 2.1/2 HT 2165 3029 4029 5205 7412 10325 354 56.65 1.33 1,064.88

*C7058 TFH4540Z Fig 4 3.0 HT 2948 4023 5263 6716 9185 12764 370 74.25 1.33 1,109.76

*C7070P^ TAG4553Z Fig 5 4.1/2 HT 3115 4537 6240 8302 12151 17756 381 100.70 1.96 1,468.80

*C7074P^ TAG4561Z Fig 5 5.0 HT 3720 5305 7171 9403 13438 19488 381 112.50 1.96 1,654.44

*C7082P^ TAG4573Z Fig 5 6.1/4 HT 5167 7018 9245 11946 16908 24235 393 134.80 1.96 1,828.86

L’Unite R404a Low TempRealcoldStock No.

Model Fig. Nom. Hp

Appl. Watts H (mm) Displ. (cm3)

OC (L) System Price$ Excl. GST

-35°C -30°C -23.3°C -20°C -15°C -10°C

Commercial 220/240 Volt 50 Hz Single Phase

C0532 AEZ2415Z Fig 1 3/8 LT 160 231 355 429 560 712 199 8.10 .45 343.74

C0545 CAE2417Z Fig 6 1/2 LT 161 280 460 557 716 891 212 11.30 .45 395.76

C0551 CAE2420Z Fig 6 1/2 LT 232 357 547 654 836 1047 212 12.54 .45 346.80

C0554 CAE2424Z Fig 6 5/8 LT 291 413 630 759 990 1266 215 15.00 .45 489.60

C0573 CAJ2432Z Fig 3 3/4 LT 310 478 765 935 1247 1593 271 18.30 .89 657.90

C0580 CAJ2446Z Fig 3 1 LT 546 799 1194 1443 1848 2322 282 26.15 .89 748.68

C0592 CAJ2464Z Fig 3 1.1/2 LT 760 1096 1605 1887 2412 3030 282 34.45 .89 792.54

*C0599 FH2480Z Fig 4 2 LT 738 1319 2183 2662 3551 4505 370 53.20 1.625 1,122.00

C0600 FH2511Z Fig 4 3 LT 1380 2016 3135 3796 4931 6303 370 74.25 1.625 1,015.00

Commercial 400 Volt 50 Hz Three Phase

*C7120 TFH2480Z Fig 4 2.0 LT 738 1319 2183 2662 3551 4505 354 53.20 1.625 1,083.24

*C7122P^ TFH2511Z Fig 4 3.0 LT 1380 2016 3135 3796 4931 6303 354 74.25 1.625 1,208.70

*C7126P^ TAG2516Z Fig 5 4.0 LT 1765 2704 4356 5335 7043 9038 381 112.50 1.96 1,645.26

*C7128P^ TAG2522Z Fig 5 5.0 LT 2395 3542 5522 6688 8711 11062 393 134.80 1.96 1,777.86

All above compressors use Polyolester Oil and require fan cooling. Use Acid-Away to solve burn-outRefer to Realcold Technical Department for Tandem Compressor packages up to 12HP. and acid build up situations.* These items include crankcase heater and oil sight glass. P^ These items include an oil level sight glass and connections for oil and pressure equalising lines.

CC67

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED RECIPROCATING

L’Unite R134a Low TempColumn Key: D = Displacement, OC = Oil Charge, FIG = Picture # Control = Cap/TEV for all models listed FIG = Picture # on page CC72-CC73

RealcoldStock No.

Model Fig Nom. Hp

Appl. Capacity (w) @ 32° Ambient H (mm)

D (cm3)

OC (L) C Control System Price$ Excl. GST

-35°C -30°C -23.3°C -20°C -15°C -10°C

Domestic - Commercial 220/240 Volt 50 Hz Single Phase

C0501 AZ1335Y Fig 13 1/8 LT 42 58 89 108 141 180 169 4.0 .40 S Cap 233.58

C0513 THB1340Y Fig 13 1/8 LT 44 66 104 126 163 205 169 4.23 .25 S Cap 240.00

C0508 THB1365Y Fig 5 1/5 LT 68 96 147 177 229 289 169 6.1 .27 S Cap 205.02

C0522 AEZ2380Y Fig 1 1/4 LT 94 144 223 267 338 417 199 9.4 .45 SOC Cap/TEV

328.44

C0530 CAE2410Y Fig 7 1/3 LT 92 151 259 324 436 566 199 12.00 .45 F Cap/TEV

377.40

C0534 CAE2412Y Fig 7 3/8 LT 96 174 306 382 514 663 199 14.20 .45 F Cap/TEV

392.70

L’Unite R134a Medium TempRealcoldStock No.

Model Fig Nom. Hp

Appl. Watts H (mm)

D (cm3)

OC (L) C Control System Price$ Excl. GST

-15°C -10°C -5°C 0°C +7.2°C +15°C

Domestic - Commercial 220/240 Volt 50 Hz Single Phase

C0511 THB4415YFZ Fig 13 1/8 HT 123 160 206 262 363 502 169 4.23 .27 S Cap/TEV

266.22

C0512 THB4419YFZ Fig 13 1/6 HT 149 194 251 319 439 602 172 5.20 .27 S Cap/TEV

288.66

C0518 AEZ4425Y Fig 1 1/5 HT 185 260 350 455 635 866 186 7.60 .45 F Cap/TEV

313.14

C0525 AEZ4430Y Fig 1 1/4 HT 245 328 432 558 777 1065 199 8.80 .45 F Cap/TEV

335.58

C0535 CAE4440Y Fig 7 1/3 HT 310 421 561 731 1026 1413 199 12.00 .45 F Cap/TEV

387.60

C0536 CAE4448Y Fig 6 3/8 HT 403 530 693 892 1242 1705 212 14.20 .45 F Cap/TEV

419.22

C0537 CAE4456Y Fig 6 3/7 HT 458 604 787 1009 1396 1904 212 16.20 .45 F Cap/TEV

450.84

C0550 CAJ4461Y Fig 3 1/2 HT 475 642 856 1115 1569 2246 258 18.30 .89 F Cap/TEV

596.70

C0575 CAJ4492Y Fig 3 3/4 HT 584 871 1215 1617 2295 3303 271 25.95 .89 F Cap/TEV

703.80

C0590 CAJ4511Y Fig 3 1 HT 878 1227 1654 2160 3026 4165 282 32.70 .89 F Cap/TEV

793.56

**C0593* FH4518Y Fig 4 1.1/2 HT 1036 1650 2371 3200 4583 6333 330 53.20 1.33 F Cap/TEV

1,013.88

**C0595* FH4525Y Fig 4 2 HT 1667 2343 3201 4239 6053 8442 354 74.25 1.33 F Cap/TEV

1,370.88

Commercial 400 Volt 50 Hz Three Phase

**C0594* TFH4518Y Fig 4 1.1/2 HT 1036 1650 2371 3200 4583 6333 354 53.20 1.33 F Cap/TEV

1,242.36

**C0596* TFH4525Y Fig 4 2 HT 1667 2343 3201 4239 6053 8442 354 74.25 1.33 F Cap/TEV

1,330.08

All above compressors use Polyolester oil.* Please state option when ordering, ie 1 phase or 3 phase.** Includes crankcase heater.

CC68

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED RECIPROCATING

L’Unite Sealed Air ConditioningRated in Watts at +7.2°C SST/+54.5°C SCT, for capillary use only.

RealcoldStock No.

Model Fig Watts H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST

Air Conditioning R22 220/240 Volt 50 Hz Single Phase

C0110 AJ5510F Fig 10 2447 271 18.60 M .89 F 677.28

C0111 AJ5512E Fig 10 2909 271 21.75 M .89 F 684.42

C0123 AJ5513E Fig 10 3214 271 24.20 M .89 F 698.70

C0124 AJ5515E Fig 10 3632 271 25.95 M .89 F 732.36

C0126 AJ5518E Fig 10 4555 282 32.70 M .89 F 732.36

C0127 AJ5519E Fig 10 4780 282 34.45 M .89 F 773.16

C0129 FH5524F Fig 11 5718 330 43.50 M 1.33 F 954.72

C0138 FH5527E Fig 11 6487 330 49.10 M 1.33 F 963.90

L’Unite Sealed Tandem Compressor Kit Commercial Medium TempRealcoldStock No.

Model Fig WATTS @ -5°C SCT H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST

R22 R404a

L’Unite Tagd Twin Compressors R22/R404a 400 Volt 50Hz Three Phase

C7105 TAGD4612Z Fig 12 16368 14342 565.0 225 POE 1.96 F 4,056.54

Features of the Tandem System

• Twin compressor configuration enable a more precise control of the system capacity to match the cooling demand and thereby the number of starts to a minimum to improve reliability.

• Capacity control - cycle one compressor off at low load conditions for power saving.

• Sequence start up of compressors reducing start up current.

• 50% redundant capacity in the event of one compressor failing.

CC69

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’Unite Sealed - Introduction L’Unite Hermetique is 100% owned by Tecumseh, USA. Hermetic compressors are manufactured in Europe and marketed by Tecumseh Europe.

Where applicable all L’Unite compressors come complete with full electrics and rotalock valves included in cost. FH - TFH - TAG & *TAGD compressors come complete with crankcase heaters and oil level sight glasses. NB. A/C compressors may not have accessories attached.

Tecumseh Europe Rating ConditionsApplications Ambient Evaporator outlet and return

gas super heatedCondensing Entering exp. valve

Low Temperature domestic and commercial refrigeration (LBP) +32˚C +32˚C +54.5˚C +32˚C

Other Applications (M/HBP-AC) +35˚C 11K +54.5˚C +46.1˚C

Note: Visit www.tecumseh-europe.com for additional product information.

COMPRESSORS - SEALED RECIPROCATING

T/FH

FH

RK

CAJ

TAGD*Dual Compressor

Merits of TAGD

• capacitycontrolaccordingtothesystemdemands

• reducedenergyconsumptionduetolowtorquestartandsequencestarting

• reducednumberofstarts.

Terminology

LT (LBP) Low Temperature - Evaporating Temp Range -40˚C / -10˚C

HT (HBP) High Temperature - Evaporating Temp Range -15˚C / +15˚C

HT W (M/HBP) High Temperature Wide Range - Evaporating Temp Range -25˚C / +15˚C

AC Air Conditioning - Evaporating Temp Range -10˚C / +10˚C

S/F Static Cooled/Fan Cooled

F Fan Cooled

SOC Static with oil cooler

CAP Capillary Controlled

CAP/TEV Capillary or Expansion Valve Controlled

For suitable compressor oils, please see Lubricants Section

M Mineral Oil

AB Alkylbenzene Oil

P Polyolester Oil

Warranty: See Warranty section at front of catalogue for more details.

L’Unite Sealed Compressors

CC70

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED RECIPROCATING

Figure One Figure ThreeFigure Two

Figure Four Figure SixFigure Five

Figure Seven Figure Eight

Specified compressor heights are indicative of series dimensions.

Certain model heights vary from specification.

Please consult Realcold if the com-pressor height is crucial.

Visit www.tecumseh-europe.com for additional product information.

CC71

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED RECIPROCATING

Figure Nine Figure ElevenFigure Ten

Figure Twelve Figure FourteenFigure Thirteen

Figure Fifteen Figure Sixteen

Specified compressor heights are indicative of series dimensions.

Certain model heights vary from specification.

Please consult Realcold if the com-pressor height is crucial.

Visit www.tecumseh-europe.com for additional product information.

CC72

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED ROTARY

L’Unite Sealed Rotary Compressors - VerticalColumn Key: D = Displacement

RealcoldStock No.

Model Fig Watts H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST

L’Unite Sealed R22 220/240 Volt 50Hz Single Phase

C7210 RK5512E Fig 16 2771 290 16.3 M 0.422 F 575.28

C7216 RK5515E Fig 15 3600 312 21.4 M 0.452 F 659.94

C7218 RK5518E Fig 15 4195 312 24.4 M 0.452 F 696.66

L’Unite Sealed Rotary HGA Compressors - Horizontal - R404a Medium TempRealcoldStock No.

Model Nom. Hp Appl. Watts Displ. (m3/h)

System Price$ Excl. GST

-15°C -10°C -5°C 0°C +7.2°C +15°C

L’Unite Sealed R404a 220/240 Volt 50 Hz Single Phase

C7304 HGA4467Z 3/7 MT 679 847 1047 1283 1557 1872 9.5 683.40

C7308 HGA4480Z 1/2 MT 825 1017 1252 1530 1851 2212 11.5 888.42

C7312 HGA4492Z 1/2 MT 905 1133 1398 1706 2060 2468 12.7 902.70

C7316 HGA4512Z 5/8 MT 1163 1438 1770 2160 2609 3118 16.1 1,271.94

L’Unite R404a Low TempRealcoldStock No.

Model Nom. Hp Appl. Watts Displ. (m3/h)

System Price$ Excl. GST

-30°C -23.3°C -20°C -15°C -10°C

L’Unite Sealed R404a 220/240 Volt 50 Hz Single Phase

C7336 HGA2426Z 3/8 LT 465 630 720 883 1075 9.5 636.48

C7340 HGA2432Z 1/2 LT 566 766 873 1066 1291 11.5 683.40

C7344 HGA2436Z 1/2 LT 610 826 944 1158 1408 12.7 820.08

C7348 HGA2446Z 5/8 LT 789 1073 1227 1507 1838 16.1 834.36

Vertical Compressors Horizontal Compressor cross section Horizontal Compressor

Contact your local Realcold branch for our full range of Air Conditioning Rotary Compressors.

L’Unite R134a Medium TempRealcoldStock No.

Model Nom. Hp Appl. Watts Displ. (m3/h)

System Price$ Excl. GST

-15°C -10°C -5°C 0°C +7.2°C +15°C

L’Unite Sealed R134a 220/240 Volt 50 Hz Single Phase

C7320 HGA4445Y 1/4 MT 392 493 618 770 954 1173 9.5 588.54

C7324 HGA4450Y 1/3 MT 501 625 778 963 1184 1445 11.5 615.06

C7328 HGA4460Y 1/3 MT 537 677 844 1045 1287 1576 12.7 650.76

C7332 HGA4476Y 3/7 MT 696 870 1086 1349 1662 2030 16.1 683.40

CC73

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED ROTARY ACCESSORIES

L’Unite SealedRealcoldStock No.

Description System Price$ Excl. GST

C1900 Terminal box cover to suit AEZ compressor 9.49

C1901 Overload cover to suit CAJ compressor 13.67

C1902 Terminal box to suit CAJ compressor 62.02

C1903 Electrical Box for TAGD Packs 148.92

C1930 Sight Glass Kit to suit FH, TFH, TAG & TAN compressors 63.04

Rotalock Valves - L’Unite ReceiversRealcoldStock No.

Connection (mm)) Tube SizeOD. (mm)

System Price$ Excl. GST

C1922 19.1 6.3 87.21

C1923 19.1 9.5 87.21

C1908 23.5 6.3 84.05

C1909 23.5 9.5 84.05

Crankcase Heaters RealcoldStock No.

Model Description System Price$ Excl. GST

C1001 H-101 54W 240 Volt

Suitable for L’Unite AH and TAH compressors

Suitable for Kirby AH, AG and CL compressors

40.49

C1003 H-102 60W 240 Volt

Suitable for L’Unite AJ and CAJ compressors

Suitable for Kirby AJ compressors

48.86

C1005 Crankcase Heater to suit FH, TFH & TAG Series 90.37

C1007 Crankcase Heater to suit TAN Series - 2 per kit 145.86

Maximum Torque Settings Nm (cm Kg)

Valve Spindle

Small Valves 11.7 (115)

19 mm square body 14 (138)

22 mm square body 21 (207)

28 mm square body 35 (344)

Valve cap on Rotalock

¼” (7/16” thread) 14 (138)3/8” (5/8” thread) 30.5 (300)

½” (3/4” thread) 45 (442)

¾” (7/8” thread) 59 (580)

Rotalock valves on compressors and receivers (with joint)

¾” thread 56.5 (553)

1” thread 84.5 (829)

1 ¼” thread 141 (1382)

1 ½” thread 197 (1935)

1 ¾” thread 317 (3110)

Connections on parallel mounted versions

1 ¾” thread 107 (1050)5/8” thread 45 (442)

Sight Glass

1 1/8” 51 (500)

Rotalock Valves - L’Unite CompressorsRealcoldStock No.

Connection (mm)

Tube SizeOD. (mm)

Suits - Suction Suits - Discharge System Price$ Excl. GST

C1911 23.5 12.7 CAJ2446Z, CAJ4416Y, CAJ4492Y, CAJ9480Z

TFH4524Z, TFH4540Z, (T)FH2480Z, FH2511Z, FH4518Y, FH4525Y, (T)FH4513Z, TFH2511Z

89.30

C1912 23.5 15.9 CAJ2464Z, CAJ4511Y, CAJ4517Z, CAJ4519Z, CAJ9510Z, CAJ9513Z

- 89.30

C1913 31.8 15.9 (T)FH2480Z, (T)FH2511Z, FH4518Y, (T)FH4524Z, (T)FH4525Y

TAG2516Z, TAG2522Z, TAG4553Z, TAG4561Z, TAG4573Z

105.06

C1916 31.8 22.2 (T)FH4531Z, TAG2516Z, TAG4553Z, TFH4540Z

- 151.98

C1917 31.8 28.6 TAG2522Z, TAG4561Z, TAG4573Z - 161.16

CC74

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEALED ROTARY ACCESSORIES

Solid State Relays RealcoldStock No.

Model Description HP/Voltage System Price$ Excl. GST

C4000 ICG 220 220V Solid State Relay 1/12 HP through 1/2 HP 22.08

C4005 PO 230 230V Solid State Relay 1/12 HP through 1/2 HP 20.50

C4020 RO-82 220V Relay & Overload 1/12, 1/10, 1/8 HP 43.61

C4015 RO-62 220V Relay & Overload 1/6, 1/5 HP 43.61

C4010 RO-42 220V Relay & Overload 1/4, 1/3 HP 43.61

C4025 RSC-20 220V Solid State Start Relay & Capacitor (43 - 52MFD) 54.67

C4030 RCO-820 230V 3 n' 1 Start Relay 1/12, 1/10, 1/8 HP 59.36

C4035 RCO-620 230V 3 n' 1 Start Relay 1/6, 1/5 HP 59.36

C4040 RCO-420 230V 3 n' 1 Start Relay 1/4, 1/3 HP 59.36

C4050 SPP-5 230V Starter Pow-R-Pak PSG A/C 4000-120000 BTU 45.19

C4062 APR-5 Universal Replacement Relay Pick up voltage 130V-370V 115.26

Applications For Solid State Relays

ICG Series:

• One size for all compressors 1/12 through 1/2 HP.

• Will replace most current relays.

• Can be used with or without start capacitor.

PO Series:

• One size for all compressors 1/12 through 1/2 HP.

• Replaces all push-on current type relays.

• For use on compressors with “pin type” terminals.

• Can be used on all capacitor and non-capacitor start motors.

• Lowest resistance solid state relay.

• Will restart a balanced system within one minute.

RO Series:

• Relay and overload in one combination unit.

• Pre-wired for fast, simple installation.

• Superior locked rotor protection eliminates start winding overheating.

• Replaces all hermetic compressor relay and overload units 1/12 through 1/3 HP.

• Can be used in conjunction with a start capacitor.

RSC Series:

• One size for all compressors 1/12 through 1/2 HP both domestic and commercial.

• A combined solid state starting relay and capacitor.

• Completely pre-wired.

• Replaces current type relays.

• Provides added boost for hard start and unbalanced systems.

• Prevents low voltage starting problems. (No additional wires required.)

RCO Series:

• The 3 n’ 1 Start Relay replaces all three electrical components, Relay, Overload, and Start Capacitor, on all capillary systems.

• Completely pre-wired.

• Installs quickly and easily, simply by pushing on 3 female pin terminals.

RO

RSC

RCO

RO

ICG

PO

APR5

CC75

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - COPELAND SCROLL™

Copeland Scroll™ Compressors - IntroductionCopeland Scroll™ Compressors are manufactured by Emerson Climate Technologies.

With its European Headquarters based in Germany and manufacturing plants all around Europe, Emerson Climate Technologies is the world’s largest provider of HVAC/R solutions, delivering simple answers for commercial, industrial, and residential applications.

Standard Copeland Scroll™ Compressor unit includes:

• Compressor filled with ester oil

• Rotalock connections

• Oil sight glass

• Schraeder connection for oil fill or drain

• Rubber mountings

• Electronic protection module on all compressors from 7.5 to 15hp

Features & Benefits

• Designed to meet the specific needs in refrigeration (medium and low temperature applications).

• Wide range of operations (2 to 15hp for all R404a, R134S and R22 applications).

• High efficiencies all year round (continuous scroll flank contact maintained by centrifugal force minimizing gas leakage, maximising efficiency).

• Capacity control (modulation range is continuous from 10 to 100%).

• Compactness (Small footprint with reduced weight by up to 50% compared to standard semi-hermetic compressors).

• Robustness and reliability (Stringent qualification tests ensure maximum reliability, Teflon coated bearings, fewer parts).

• Compressor protection (All 2 to 6HP compressors are supplied with internal thermal protectors and all 7.5hp to 15hp models feature an electronic module).

• Smooth operation (Designed with a discharge check valve).

• Asercom certified performance data (Compressor delivers performance defined and published by the manufacturer via simulative data testing performed by experts and regular measurement at independent bodies.

ZB11MCE ZB92KCE ZB38KC ZB19KC ZBD45

CC76

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - COPELAND SCROLL™

Copeland Scroll™ - R22 Medium TempColumn Key: FIG = Picture #, D = Displacement, W = Weight for all models listed

RealcoldStock No.

Model Fig. Nom. Hp

Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)

Weight (Kg)

System Price$ Excl. GST

R22

- 15°C - 10°C -5°C 0°C + 5°C +7.2°C

Air Conditioning - 220/240 Volt 50 Hz Single Phase

CS0044 ZR28K3E-PFJ Fig 2 2.5 2880 3660 4530 5530 6650 7290 6.80 27 905.76

CS0047 ZR36K3E-PFJ Fig 2 3.0 3550 4430 5460 6620 7940 8690 8.60 29 991.44

CS0049A ZR42K3E-PFJ Fig 2 3.5 4190 5220 6410 7790 9370 10270 9.90 30 1,106.70

CS0050 ZR47K3E-PFJ Fig 3 4.0 5030 6320 7790 9470 11370 12435 11.0 31 1,245.42

CS0054 ZR68KCE-PFJ Fig 3 5.5 6720 8020 10210 12750 14160 15970 6.1 40 1,402.50

Air Conditioning - 380/420 Volt 50 Hz Three Phase

CS0052 ZR61KCE-TFD Fig 3 5.0 5800 7420 9330 11500 13900 15200 14.4 36 1,318.86

CS0060 ZR68KCE-TFD Fig 3 5.5 6720 8020 10210 12750 14160 15970 16.2 39 1,449.42

CS0062 ZR72KCE-TFD Fig 3 6.0 7720 9610 11750 14160 16890 18425 17.06 39 1,407.60

CS0064 ZR81KCE-TFD Fig 3 6.5 84100 10530 13040 15890 19060 20775 18.75 39 1,570.80

CS0065 ZR94KCE-TFD Fig 4 8.0 9130 11480 14060 17000 20410 22395 22.12 57 2,089.98

CS0067 ZR108KCE-TFD Fig 4 9.0 11200 14080 17320 20970 25130 27505 24.87 60 2,363.34

CS0069 ZR125KCE-TFD Fig 4 10.0 12980 16320 20070 24300 29130 31880 29.08 61 2,472.48

CS0071 ZR144KCE-TFD Fig 4 12.0 14770 19020 23680 28890 34780 37630 33.20 61 2,724.42

R404a Medium TempRealcoldStock No.

Model Fig Nom. Hp

Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)

Weight (Kg)

System Price$ Excl. GST

R404a

-15°C -10°C -5°C 0°C +5°C +7.2°C

Air Conditioning - 380/420 Volt 50 Hz Three Phase - R410a*

CS0220 ZP235KCE-TWD-522

Fig 5 20.0 25100 31300 38400 46600 53350 60100 36.30 140 7,491.90

CS0230 ZP385KCE-TWD-522

Fig 5 30.0 41600 51400 62800 76000 86850 97700 66.70 176 10,416.24

* A full range of R410a Scroll Compressors is available on indent

R404a Low TempRealcoldStock No.

Model Fig Nom. Hp

Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)

System Price$ Excl. GST

R404a

-25°C -20°C -15°C -10°C -5°C 0°C +7.2°C

Refrigeration 380/420 Volt 50 Hz Three Phase

CS0017 ZF18K4E-TFD Fig 6 6.0 5.14 6.39 7.89 9.66 11.75 14.15 18.25 17.06 3,430.26

CS0020 ZF24K4E-TWD Fig 7 7.5 6.37 7.89 9.69 11.80 14.35 17.35 22.40 20.86 4,369.68

CS0024 ZF33K4E-TWD Fig 7 10.0 8.75 10.90 13.45 16.50 20.10 24.30 31.30 28.78 4,916.40

CS0028 ZF40K4E-TWD Fig 8 13.0 10.85 13.45 16.55 20.20 24.60 29.70 38.30 35.55 5,435.58

CS0032 ZF48K4E-TWD Fig 8 15.0 13.10 16.35 20.20 24.80 30.10 36.20 46.30 42.76 5,962.92

CS0118 ZB30KCE-TFD Fig 9 4.0 3.19 4.07 5.12 6.37 7.84 9.56 13.85 11.68 1,801.32

CS0120 ZB38KCE-TFD Fig 9 5.0 4.01 5.09 6.38 7.91 9.72 11.85 15.40 14.37 1,875.78

CS0122 ZB45KCE-TFD Fig 9 6.0 4.73 6.00 7.51 9.31 11.45 13.90 18.05 17.06 2,011.44

CS0126 ZB58KQE-TFD Fig 10 8.0 5.25 7.42 9.75 12.35 15.25 18.60 24.10 22.12 2,485.74

CS0130 ZB76KQE-TFD Fig 11 10.0 8.12 10.55 13.35 16.55 20.30 24.70 31.90 28.82 2,653.02

CS0136 ZB92KCE-TWD Fig 1 13.0 9.00 12.30 16.00 20.10 24.90 30.30 39.10 35.55 5,502.90

CS0138 ZB11MCE-TWD Fig 1 15.0 12.45 15.50 19.15 23.40 28.40 34.20 43.50 42.76 6,112.86

Note: Duty ratings based on 45°C condensing temp & 2K sub-cooling.

CC77

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - COPELAND SCROLL™

Copeland Scroll™ Compressors AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

CCS1000 Start Capacitor ZR68 52.02

CCS1001 Start Capacitor ZR28 - 47 22.08

CCS1002 Run Capacitor ZR68 33.66

CCS1003 Run Capacitor ZR28 22.59

CCS1004 Run Capacitor ZR42 - 47 38.91

CCS1005 Run Capacitor ZR36 24.17

CCS1006 C/Case Heater ZR84 -144, ZB58-76 46.77

CCS1007 C/Case Heater ZR22 - 81, ZB30-45 32.08

CCS1008 Crankcase Heater ZR16 - 19M 32.08

CCS1009 Suction Rotalock Seal 1.12

CCS1010 Suction Rotalock Seal 4.85

CCS1011 Potential Relay ZR68 110.16

CCS1012 Current Relay ZF 171.36

CCS1013 Potential Relay ZR28 - 42 35.75

CCS1014 Summit Temp T/Stat 23.66

CCS1017 Valve Kit ZB58 194.82

CCS1018 Valve Kit ZF18 126.48

CCS1019 Valve Kit ZF24 183.60

CCS1020 Valve Kit ZF33 - 40, ZB92 173.40

CCS1021 Valve Kit ZF48, ZB11 216.24

CCS1023 CC Heater ZF40 - 48, ZB92 39.42

CCS1024 Crankcase Heater ZP385 82.52

CCS1025 Crankcase Heater ZP235 79.36

Figure One Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) H (mm)

ZB92KCE 492 209 176 306 55 88 551

ZB11MCE 533 209 176 306 55 88 596

Note: Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.

Figure One

CC78

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - COPELAND SCROLL™

Figure Two Dimensions Model H (mm) D (mm) S (mm)

ZR28K3E 383 357 264

ZR36K3E 406 380 283.5

ZR42K3E 419 393.8 296.3

Figure Three Dimensions Model H (mm) D (mm) S (mm)

ZR47K3E 436

ZR61KCE 476 429 316

ZR68KCE 476 429 316

ZR72KCE 476 429 316

ZR81KCE 462 433 316

Figure Two Figure Three

Figure Four Dimensions Model H (mm) D (mm) S (mm)

ZR94KCE 495 463 113

ZR108KCE 552 520 141

ZR125KCE 552 520 141

ZR144KCE 552 520 141

Figure Five Dimensions Model H (mm) D (mm) S (mm)

ZP235KCE 713 685 352

ZP385KCE 716 678 394

Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.

Figure Four Figure Five

Air Conditioning

CC79

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - COPELAND SCROLL™

Figure Eight Figure Nine

Figure Six Figure Seven

Figure Ten Figure Eleven

Figure Six Dimensions Model A +/- 3 (mm) C +/- 3 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)

ZF18K4E 410 233 297 48 81 341 489

Figure Seven Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)

ZF24K4E 496 209 176 306 55 88 359 561

ZF33K4E 496 209 176 306 55 88 359 561

Figure Eight Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)

ZF40K4E 504 209 176 306 55 88 366 569

ZF48K4E 533 209 176 306 55 88 366 598

Figure Nine Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) H (mm)

ZB30KCE 410 233 - 297 48 81 457

ZB38KCE 410 233 - 297 48 81 457

ZB45KCE 410 233 - 297 48 81 457

Figure Ten Dimensions Model H (mm) W (mm) L (mm)

ZB58KQE 477 284.2 263.6

Figure Eleven Dimensions Model H (mm) W (mm) L (mm)

ZB76KQE 546.1 284.2 263.6

Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.

Refrigeration

CC80

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI SEALED RECIPROCATING

Frascold Semi Sealed Compressors - IntroductionFrascold History:

The Fraschini Company was founded in 1936 to produce open drive compressors. Renamed Frascold in 1965, the company continued to develop its range of open drive compressors, adding a semi-hermetic reciprocating range by 1975. Since 1987 the factor production line has been continually upgraded with computer controlled machining processes, and this has enabled Frascold to increase production and maintain very high manufacturing standards. Quality control procedures conform to EN ISO 9001 standard.

Frascold’s initiative and technology has led to the development of its low clearance high capacity design, where the piston head is shaped to suit the suction valve reed profile. This results in very low clearance, which is a major factor in improving performance and efficiency in respect to standard compressors.

The process of continual improvements has made Frascold a world leader as a manufacturer and supplier of semi-hermetic compressors throughout the world. Its modern, high performance range of semi-hermetic compressors is suitable for Refrigeration and Air Conditioning applications. Ranging from 3.93 cubic metres per hour through to 205.80 cubic metres per hour and with refrigeration capacities from 200 watts through to 280,000 watts, Frascold’s semi-hermetic compressors are able to run on a large range of modern refrigerants.

Notes on the Frascold Range

Please note that the superheat of the suction vapour entering the compressor must not exceed the values stated by the manufac-turer. Failure to adhere to this will void any warranty or performance claims.

Frascold offers a range of CO2 compressors, suitable for sub-critical system from 1.5HP to 9HP and trans-critical 10HP to 25HP.

Evaporating Range - Guideline Only

All compressors are suction vapour cooled. Refer to Compressor Data Book for individual operating ranges.

H +10°C/0°C M 0°C/-15°C L -15°C/-30°C

See Warranty section at the front of catalogue for Warranty details

Single Phase: Protection with thermal Klixon.

Three Phase: Inherent protection, thermistor with control relay.

All Frascold compressors are charged with Polyolester oils. Please refer to our Technical Department for refrigerant blend applications.

Our Technical Department is only too happy to select equipment and provide quotations for all your requirements. Refer to Spares Section at the rear of this catalogue, for Frascold Compressor Spares.

CC81

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI SEALED RECIPROCATING

Frascold Semi Sealed - Medium/ Low TempColumn Key: FIG = Picture #, D = Displacement, W = Weight for all models listed

RealcoldStock No.

Model Hp/kW Nom.

Disp. m3/hr

Oil ChargeLitres

Nominal Capacity (Kw) System Price$ Excl. GST

R404a R134a

-5.00 -25.00 -5.00

Single Phase 220/240 Volt 50 Hz

C5016 A16 1.0 5.47 1.25 3.30 1.40 1.60 2,176.68

C5033 A157 1.5 6.91 1.25 4.20 1.70 2.00 2,178.72

C5038 B159 1.5 8.96 1.25 5.30 2.20 2.60 2,244.00

Three Phase 380/415 Volt 50 Hz

C5031 A157 1.5 6.91 1.25 4.20 1.65 2.60 2,175.66

C5036 B159 1.5 8.96 1.25 5.30 2.00 3.40 1,864.56

C5046 B210 2.0 9.84 1.25 5.90 2.30 3.70 2,175.66

C5051 D213 2.0 13.84 1.5 - 3.20 5.00 2,762.16

C5061 D313 3.0 13.84 1.5 8.20 3.10 4.90 2,921.28

C5071 D318 3.0 17.93 1.5 - 4.50 6.90 2,911.08

C5078 D418 4.0 17.93 1.2 11.20 4.60 7.20 2,909.04

C5086 F424 4.0 23.6 2.6 14.70 5.80 9.10 3,374.16

C5095 F524 5.0 23.6 2.6 14.50 5.50 8.90 3,211.98

C5096 Q528Y 5.0 27.88 1.8 - 6.70 10.20 3,942.30

C5097 Q533Y 5.0 32.66 1.8 - 8.10 11.90 4,266.66

C5098 Q728 7.5 27.31 2.6 17.70 6.90 10.20 4,195.26

C5124 S733 7.5 32.8 3.3 20.70 8.30 12.80 5,203.02

C5127 S739 7.5 38.25 3.3 24.60 10.20 15.30 5,365.20

C5129 S1039 10.0 38.25 3.3 24.60 10.20 15.20 5,508.00

C5133 S1051 10.0 50.43 3.3 - 13.20 19.50 5,973.12

C5137 S1551 15.0 50.43 3.3 31.70 12.70 19.30 5,200.98

C5155 V1559 15.0 58.48 4.25 37.30 15.20 23.30 6,701.40

C5160 V1571 15.0 70.77 4.25 - 17.90 27.60 7,723.44

C5165 V2059 20.0 58.84 4.25 36.80 13.50 23.40 7,138.98

C5172 V2084 20.0 83.81 4.25 - 20.20 30.40 8,746.50

C5185 V2571 25.0 70.77 4.25 44.20 16.50 26.60 8,892.36

C5190 Z25106 25.0 106.16 5 67.90 25.70 37.80 11,516.82

C5192 V3084 30.0 83.81 4.25 53.30 20.20 30.50 9,754.26

C5198 Z30126 30.0 125.72 7.5 - 29.80 46.50 12,377.70

C5200 Z35106 35.0 106.16 5 67.50 25.80 40.90 11,503.56

C5206 Z40126 40.0 125.72 7.5 79.00 29.50 48.20 12,816.30

C5210 Z40154 40.0 154.38 7.5 - 40.00 56.20 14,991.96

C5215 Z50154 50.0 154.38 7.5 96.30 36.20 57.50 16,014.00

C5233 W50187 50.0 186.1 8 - 42.90 68.60 18,202.92

C5234 W60187 60.0 186.1 8 119.70 44.90 69.80 18,933.24

C5235 W60206 60.0 205.8 8 131.20 49.60 78.80 19,904.28

C5238 W70206 70.0 205.8 8 131.00 49.50 77.60 20,247.00

Note: Frascold offers a range of: i) R410a semi-hermetic compressors from 7.5 HP to 15 HP ii) CO² sub-critical Semi-hermetic compressors from 1.5 HP to 10 HP iii) CO² trans-critical semi-hermetic compressors from 10 HP to 25 HP

Visit www.frascold.com for additional product information.

Realcold offer equipment selection services. Please feel free to use this service. Refer to spares section at rear for Frascold compressor spares.

A

V

D

F

S

Z

W

B

CC82

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI SEALED RECIPROCATING

Capacity ControlRealcoldStock No.

Description System Price$ Excl. GST

C5221 To suit "T" & "S" Series (Mk II) 1 cylinder head c/w solenoid 50% control 402.90

C5225 To suit “Z” & “V” & “W” Series 1 head only.

1 head for “V”=50% control. 1 head for “Z” = 33% control

2 heads for “Z”=33% & 66% control (Z:33%+66% = 2 x C5225)

2 heads for “W”=50% & 75% control (W:50%+75% = 2 x C5225)

430.44

AccessoriesRealcoldStock No.

Description Wattage Incl. Installation System Price$ Excl. GST

R0316 Rubber Mounts 40 x 40 mm 2 - 3 HP 35.75

R0552 Crankcase Heater F, S, T Series 70 Watt Fitted 160.14

R0553 Crankcase Heater A, B, D Series 50 Watt Fitted 160.14

R0555 Crankcase Heater (to suit V, W, Z Series) MK 2 150 Watt Fitted 238.68

C5805 Head Cooling Fan (to suit A, B, D, F Series) Fitted 514.08

C5808 Head Cooling Fan (to suit S, T, V, Z Series) Fitted 532.44

R0824 Delta-P Oil Differential Pressure Switch suits V, Z and W Series.

The Delta-P is easy and fast to mount, with no mounting bracket required. The electric component can be removed without refrigerant leakage. Includes a reset push button.

536.52

Higher efficiency with Low Clearance High Capacity (LCH)

LCH design, distinguished the piston-valve plate assembly, is the final result of a close research in order to reduce clearance, the most important reason of loss of computer efficiency. To considerably restrict such efficiency loss, FRASCOLD has shaped the head of the piston so that it matches suction valve reed profile.

In the compressor with LCH design, contoured piston lower cylinder clearance and an increase in capacity and efficiency it results respect to the performance of a standard compressor.

Note: For Frascold Lubricants please refer to page CL114.

CC83

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI-HERMETIC SCREW

Semi-Hermetic Screw Compressor - IntroductionFrascold started manufacturing a range of twin screw compressors in 1995.

The twin screw compressor range comprises twenty four models across three ranges.

C-TSH Range: This range of compact twin screw compressors comprises eight models from a nominal 40HP to 120HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The C-TSH range is suited to applications in the operating temperature range from +12.5°C to -15°C on R22/ R407c/ R134a/ R404a. Compressors are fitted with integral oil separator / reservoir.

C-XH0 Range: This range of compact twin screw compressors comprises twenty seven models from a nominal 50HP to 300HP, with displacements from 199 to 912 cubic metres per hour at 50Hz. The C-XH0 range is suited to applications in the operating temperature range from +12.5°C to -15°C on R407c/R134a; +0°C to -25°C on R404a/R507. Compressors are fitted with integral oil separator / reservoir.

R-TSH Range: This range comprises eight models from nominal 40HP to 120HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The R-TSH range is suited to air conditioning and medium/ high temperature applications, in the temperature operating range from + 7. °5C to - 20°C on R404a/R507A; +12.5°C to -20°C on R22; +20°C to -10°C on R134a.

R-TSL Range: This range comprises eight models from nominal 30HP to 100HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The R-TSL range is suited to low temperature applications, in the temperature operating range from -20°C to -45°C on R404a/R507A

Outstanding Features Screw Profiles: The compressors are two-shaft rotary displacement design, with innovative profiles of the screws. (Ratio 5:6 between male & female screw). The shafts are fitted with large roller bearings sized to bear both radial and axial loads, resulting in reduction of friction, vibration and lower noise levels. Discharge check valve, located in the service valve prevents counter rotation when compressor stops operating.

Electric Motor: High efficiency electric motor is two-pole, three phase asynchronous type. The rotor is fitted to the shaft of the male screw. Cooling of the motor is carried out by the suction gas flowing through slots in the rotor, also causing any liquid refrigerant to be separated due to the centrifugal action.

Power Supply: 400/3/50

Connection: Part Winding Start (PWS) 50% + 50% current distribution

Capacity Control: All compressors are fitted with capacity control, which operates by means of a three-way solenoid valve, directing the flow of oil under pressure, to a slide piston mechanism. At full load, oil under pressure pushes against the piston, opposing the spring and closing the capacity control device. At reduced load conditions, the oil is diverted to the suction side of the compressor, and the spring forces the piston to open the capacity control device, which reduces the displacement and consequently reduces the capacity of the compressor.

E-Protection Device: All screw compressors are equipped with electronic protection called KRIWAN NT 68 FRY, complete with thermistor sensors, performing the following functions:

• Controlofmaximumtemperatureoftheelectricmotor+120°C,throughsixPTCthermistors,fittedtothestatorwinding.

• Controlofthemaximumdischargetemperature+120°CthroughPTCsensorplacedoncompressordischargeside.

• Controlofrotationdirectionoftheelectricmotorandphasesequence.

• Protectionofphaseandvoltagefailures.

• ControlofbreakageandshortcircuitinchainofPTCsensors.

Screw compressors can be installed in parallel configurations and the R series are well suited to two-stage systems.

Capacity Control StepsModel Number % of full capacity - Steps

R-TSH8 40 120Y; R-TSL8 30 120Y 100 - 50; one stage capacity control

R-TSH8 50 150Y; R-TSL8 40 150Y 100 - 50; one stage capacity control

R-TSH8 60 186Y; R-TSL8 50 186 Y 100 - 50; one stage capacity control

R-TSH8 70 210Y; R-TSL8 60 210Y 100 - 50; one stage capacity control

R-TSH8 80 240Y; R-TSL8 70 240Y 100 - 75 - 50; two stage capacity control

R-TSH8 90 270Y; R-TSL8 80 270Y 100 - 75 - 50; two stage capacity control

R-TSH8 100 300Y; R-TSL8 90 300Y 100 - 75 - 50; two stage capacity control

R-TSH8 120 360Y; R-TSL8 100 360Y 100 - 75 - 50; two stage capacity control

CC84

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI-HERMETIC SCREW

Compact Twin Screw Compressor - Medium TemperatureRealcoldStock No.

Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST

C5251 C-TSH8 40 120Y MBP-HBP 40/30 120 18,949.56

C5252 C-TSH8 50 150Y MBP-HBP 50/37 150 19,612.56

C5253 C-TSH8 60 186Y MBP-HBP 60/45 186 21,560.76

C5254 C-TSH8 70 210Y MBP-HBP 70/52 210 22,204.38

C5255 C-TSH8 80 240Y MBP-HBP 80/60 240 24,834.96

C5256 C-TSH8 90 270Y MBP-HBP 90/67 270 26,122.20

C5257 C-TSH8 100 300Y MBP-HBP 100/75 300 28,753.80

C5258 C-TSH8 120 360Y MBP-HBP 120/90 360 30,040.02

Note: These Compressors are available as indent stock only

CXHO Compact Twin Screw CompressorsRealcoldStock No.

Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST

R134a

CFS0020 CXH0 50 199Y CXH0 50/37 199 17,124.78

CFS0022 CXH0 60 230Y CXH0 60/45 230 17,839.80

CFS0024 CXH0 70 264Y CXH0 70/52 264 20,529.54

CFS0026 CXH0 80 298Y CXH0 80/60 298 21,243.54

CFS0028 CXH0 90 340Y CXH0 90/67 340 22,230.90

CFS0030 CXH0 100 370Y CXH0 100/75 370 27,610.38

CFS0034 CXH0 110 398Y CXH0 110/81.5 398 29,879.88

CFS0036 CXH0 125 468 CXH0 125/93.8 468 30,720.36

CFS0038 CXH0 140 538Y CXH0 140/104 538 31,854.60

CFS0042 CXH0 160 620Y CXH0 160/118.8 620 40,343.04

CFS0044 CXH0 180 702Y CXH0 180/133.7 702 44,440.38

CFS0046 CXH0 210 810Y CXH0 210/156 810 48,138.90

CFS0048 CXH0 240 912Y CXH0 240/178.3 912 50,261.52

R407c & R404a

CFS0060 CXH0 70 199Y CXH0 70/52 199 18,133.56

CFS0062 CXH0 80 230Y CXH0 80/60 230 19,120.92

CFS0064 CXH0 90 264Y CXH0 90/67 264 21,663.78

CFS0066 CXH0 100 298Y CXH0 100/75 298 23,366.16

CFS0068 CXH0 120 340Y CXH0 120/88 340 24,773.76

CFS0072 CXH0 110 316Y CXH0 110/81.5 316 27,190.14

CFS0074 CXH0 125 372Y CXH0 125/93.8 372 28,324.38

CFS0076 CXH0 140 428Y CXH0 140/104 428 30,720.36

CFS0078 CXH0 160 468Y CXH0 160/120 468 32,568.60

CFS0082 CXH0 180 545Y CXH0 180/133.7 545 41,204.94

CFS0084 CXH0 210 620Y CXH0 210/156 620 48,265.38

CFS0086 CXH0 240 702Y CXH0 240/178.3 702 49,252.74

CFS0088 CXH0 280 810Y CXH0 280/208 810 52,089.36

CFS0090 CXH0 300 912Y CXH0 300/222.9 912 54,631.20

Note: that these Compressors are available as Indent stock only

CC85

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI-HERMETIC SCREW

Standard equipment - MBP-HBP

Screw compressor is supplied complete with:

• oil separator directly assembled with flange to the compressor body

• oil demister inside the separator

• oil strainer

• discharge connection complete with valve and check valve

• suction valve

• internal relief valve

• capacity control device

• electronic protection device

• electric box with IP65 protection

• oil heater

• vibration absorbers

Standard equipment - CXH0

• Discharge valve & integrated check valve

• Suction flange with solder busching

• Integrated pressure relief valve

• Capacity control (step or step less)

• Motor with ptc-temperature sensors

• Electronic control unit (temperature and phase sequence monitoring auto reset)

• Terminal box enclosure class IP65

• Oil service valve, oil filter, sight glass & oil charge

• Start unloading

• Discharge temperature sensor

• Protective charge

Twin Screw Compressors - Medium TemperatureRealcoldStock No.

Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST

C5261 R-TSH8 40 120Y MBP 40/30 120 17,641.92

C5262 R-TSH8 50 150Y MBP 50/37 150 18,304.92

C5263 R-TSH8 60 186Y MBP 60/45 186 20,254.14

C5264 R-TSH8 70 210Y MBP 70/52 210 20,897.76

C5265 R-TSH8 80 240Y MBP 80/60 240 23,529.36

C5266 R-TSH8 90 270Y MBP 90/67 270 24,834.96

C5267 R-TSH8 100 300Y MBP 100/75 300 27,448.20

C5268 R-TSH8 120 360Y MBP 120/90 360 28,753.80

Twin Screen Compressor - Low Temperature

C5271 R-TSL8 30 120Y LBP 30/22 120 16,978.92

C5272 R-TSL8 40 150Y LBP 40/30 150 17,641.92

C5273 R-TSL8 50 186Y LBP 50/37 186 19,201.50

C5274 R-TSL8 60 210Y LBP 60/45 210 19,864.50

C5275 R-TSL8 70 240Y LBP 70/52 240 22,204.38

C5276 R-TSL8 80 270Y LBP 80/60 270 23,529.36

C5277 R-TSL8 90 300Y LBP 90/67 300 26,122.20

C5278 R-TSL8 100 360Y LBP 100/75 360 27,448.20

Note: These Compressors are available as indent stock only

Standard equipment - MBP-LBP

Standard equipment mounted on the compressor

• capacity control device

• integral electronic protection, includes:

o sensor for maximum discharge temperature

o sensor for maximum temperature of electric motor

o electronic module

• suction valve

• discharge valve with check valve

Standard equipment supplied loose with compressor

• vibration absorbers

• components for external oil piping, includes:

o oil strainer with core

o solenoid valve with coil and plug

o oil flow switch

o electronic module for oil flow switch

o oil sight glass

CC86

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI-HERMETIC SCREW

Semi-Hermetic Screw Compressor - AccessoriesRealcoldStock No.

Model Description System Price$ Excl. GST

C5820 TOOWK150 Visual Indicator POA

C5822 TOOWK151 Visual Indicator POA

C5824 SZ-WOC1 Water Cooled Oil Cooler POA

C5826 SZ-WOC2 Water Cooled Oil Cooler POA

C5828 SZ-WOC3 Water Cooled Oil Cooler POA

C5830 SZ-AOC1 Air Cooled Oil Cooler POA

C5832 SZ-AOC2 Air Cooled Oil Cooler POA

C5834 SZ-AOC3 Air Cooled Oil Cooler POA

C5836 TOOWK200 Remote Oil Separator POA

C5838 TOOWK201 Remote Oil Separator POA

C5840 TOOWK202 Remote Oil Separator POA

C5844 TOOWK301 Economizer R404a POA

C5848 TOOWK303 Economizer R404a POA

C5852 TOOWK305 Economizer R404a POA

C5856 TOOWK307 Economizer R404a POA

C5858 TOOWK400 Liquid Injection Valve POA

C5860 SZ-OIL1 FC300 19 Litre Oil (M/T R404) POA

C5862 SZ-OIL3 FC170 19 Litre Oil (L/T R404a) POA

C5864 SZ-OIL2 FC170 25 Litre Oil (L/T, M/T R22) POA

C5866 T00WK110 Oil Filter Kit POA

Oil Separator

Sub CoolerAir Cooled Air Cooler

Diagram Legend:

Oil Separator Sub Cooler

1 = Refrigerant Outlet F1 = Economiser Outlet

2 = Service Valve Connection F2 = Liquid Inlet for Sub Cooling

3 = Refrigerant Inlet F3 = Refrigerant Inlet for TEV

4 = Connection for Oil Charge Valve F4 = Liquid Outlet - Subcooled Liquid

5 = Oil Level Sight Glass

6 = Parallel Compressors Oil Outlet

7 = Oil Level Control

8 = Oil Outlet

9 = Oil Heater

10 = Safety Valve Connection

11 = Thermostat Sensor

CC87

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSORS - SEMI-HERMETIC SCREW

Semi-Hermetic Screw Compressor - AccessoriesCompressor Model

R-TS

H1

40 1

20 Y

R-TS

H1

50 1

50 Y

R-TS

H1

60 1

86 Y

R-TS

H1

70 2

10 Y

R-TS

H1

80 2

40 Y

R-TS

H1

90 2

70 Y

R-TS

H1

100

300

Y

R-TS

H1

120

360

Y

R-TS

L1 3

0 12

0 Y

R-TS

L1 4

0 15

0 Y

R-TS

L1 5

0 18

6 Y

R-TS

L1 6

0 21

0 Y

R-TS

L1 7

0 24

0 Y

R-TS

L1 8

0 27

0 Y

R-RS

L1 9

0 30

0 Y

R-TS

L1 1

00 3

60 Y

remote oil separator

TOOWK200 • • • • • • • • • •

TOOWK201 • • • • • •

TOOWK202

visual indicator for oil strainer clogging

TOOWK150 • • • • • • • • • • • • • • • •

electric indicator for oil strainer clogging

TOOWK151 • • • • • • • • • • • • • • • •

water cooled oil cooler

SZ-WOC1 • • • • • • • • • • • •

SZ-WOC2 • • • •

SZ-WOC3

air cooled oil cooler

SZ-AOC1 • • • • • • • • • • • •

SZ-AOC2 • • • •

SZ-AOC3

economizer kit for R22

TOOWK300 • •

TOOWK302 • •

TOOWK304 • •

TOOWK306 • •

economizer kit for R404a-R507A

TOOWK301 • •

TOOWK303 • •

TOOWK305 • •

TOOWK307 • •

lubricant for R22 (19I can)

SZ-OIL2 (FCH) • • • • • • • • • • • • • • • •

lubricant R404a, 50W7A, R143A (19I can)

SZ-OIL3 (FCL) • • • • • • • • • • • • • • • •

CD88

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DEFROST CONTROLS

Defrost ControlsRealcoldStock No.

Model Description System Price$ Excl. GST

G0090 PARAGON

8145-21

(Replaces Precision 6145-21)

• Time initiated.

• Externally temperature or pressure terminated.

• 1 - 6 defrosts per 24 hours.

• Minimum of 4 hours between defrost.

• Length of defrost 4 to 110 minutes in 2 minute increments.

• Has relay contact facility.

• Suitable for 208 - 240 V 50 Hz.

• Maximum contact rating is 25 Amps.

296.20

G0091 PARAGON

632-21*

• Time initiated, time terminated with fan delay.

• 1 - 8 defrost per 24 hours.

• Minimum of 3 hours between defrosts.

• Pre-defrost delay 0 to 30 minutes in 3 minute increments.

• Defrost period 3 to 45 minutes in 3 minute increments.

• Post defrost delay 3 to 15 minutes in 3 minute increments.

• Suitable for 208 - 240 V 50 Hz.

• Maximum contact rating is 10 Amps.

539.90

G0092 PARAGON

8045-21

(Replaces Precision 6045-21)

• Time initiated, time terminated.

• 1 - 6 defrosts per 24 hours.

• Minimum of 4 hours between defrosts.

• Length of defrost 4 - 110 minutes in 2 minute increments.

• For basic defrost systems.

• Suitable for 220 - 240 V 50 Hz.

• Maximum contact rating is 25 Amps.

275.88

G0093 PARAGON

8245-21

(Replaces Precision 6245-21)

• Time initiated, pressure terminated.

• 1 - 6 defrosts per 24 hours.

• Minimum of 4 hours between defrosts.

• Length of defrost 4 to 110 minutes in 2 minute increments.

• Adjustable cut-in setting dial calibrated from 36-110 psi

• (248 - 758 kPa) for R12, R22, R502.

• Suitable for 208 - 240 V 50 Hz.

• Maximum contact rating is 40 Amps.

595.00

G0084 FRIGO FLASH

16022*

• Compact Series 72 mm x 72 mm

• 24 hour clock

• Supply voltage 220 / 240 V +10% - 15% 50 / 60 Hz

• Operating Temperature: -10°C/ +50°C

• 10 minute programming segments

• 72 switchings per day

• Minimum interval between 2 switchings: 20 minutes

• Contact ratings: 16 Amp resistive, 3 Amp inductive

132.80

G0086 FRIGO FLASH

11721*

• 72 mm x 102.5 mm

• 24 hour clock

• Supply voltage 220 V +10% - 15% 50 Hz

• Operating Temperature: -10°C/ +50°C

• Up to 12 defrosts per day

• Defrosting can be started every 2 hours

• Defrost duration 5 - 110 minutes

• Contact ratings: 10 Amp resistive, 2 Amp inductive

172.43

* NB: External relay may be required in some applications.

CD89

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DEFROST CONTROLS & ACCESSORIES

Defrost Safety ThermostatsRealcoldStock No.

Model Description System Price$ Excl. GST

G0014 ML55 Thermostat 10 Amps Open +13°C Close +2°C 12.09

G0016 ML70 Thermostat 10 Amps Open +21°C Close +10°C 12.09

W7520 - Thermal Overload (Defrost Klixon) 25 Amp 74.10

G0020 GL243 Surface Mount Clip (3 per Pack) 9.08

G0022 GL249 Tube Mount Clip 3/8 - 1/2 - 5/8 (2 per Pack) 18.41

Defrost Heat TapeRealcoldStock No.

Model Description System Price$ Excl. GST

N0626 FST25Jimi Heat Self Regulating Tape 26W/M at 10°C - 240 VAC

Minimum installation temperature -40°C

32.13

N0635 Seal Kit FCT BTV-2 30.00

N0616 and N0626 can be used in evaporator drains, provided correct termination kits are fitted.

Condensate PansThe MA-Line condensate evaporator pan eliminates floor drains. The unit is made of die-cast aluminium and the resulting hard, bright surface give the pan unequalled efficiency and trouble free operation. The pan is self standing. All terminal connections are covered with moisture proof rubber. Evaporation rate is 250ml per hour at 22.2°C room temperature. The unit’s heating element is sealed in ¼” Bundy weld tubing.

RealcoldStock No.

Description Voltage Watts Dimensions (mm) System Price$ Excl. GST

L W H

C4080 MA-Line Condensate Pan - Small 240V 160 260 103 60 234.60

C4082 MA-Line Condensate Pan - Large 240V 160 260 121 75 234.60

N0616 and N0626 can be used in evaporator drains, provided correct termination kits are fitted.

CD90

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DRIERS

Sporlan Driers - FlareRealcoldStock No.

Brand Model Size Cu In System Price$ Excl. GST

Liquid Line Driers - Sporlan

SP3001 Sporlan CATCH-ALL 032 1/4" MF 3 23.18

SP3002 Sporlan CATCH-ALL 052 1/4" MF 5 30.90

SP3003 Sporlan CATCH-ALL 082 1/4" MF 8 37.00

SP3004 Sporlan CATCH-ALL 162 1/4" MF 16 45.79

SP3008 Sporlan CATCH-ALL 053 3/8" MF 5 30.90

SP3009 Sporlan CATCH-ALL 083 3/8" MF 8 37.00

SP3011 Sporlan CATCH-ALL C163 3/8" MF 16 45.79

SP3012 Sporlan CATCH-ALL 303 3/8" MF 30 88.25

SP3015 Sporlan CATCH-ALL 084 1/2” MF 8 37.54

SP3017 Sporlan CATCH-ALL 164 1/2" MF 16 50.23

SP3018 Sporlan CATCH-ALL 304 1/2" MF 30 88.25

SP3022 Sporlan CATCH-ALL 165 5/8" MF 16 52.43

SP3023 Sporlan CATCH-ALL 305 5/8" MF 30 88.25

Sporlan Driers - SweatRealcoldStock No.

Brand Model Size Cu In System Price$ Excl. GST

Liquid Line Driers - Sporlan

SP3071 Sporlan CATCH-ALL 032S 1/4" SWEAT 3 22.08

SP3072 Sporlan CATCH-ALL 052S 1/4" SWEAT 5 29.43

SP3073 Sporlan CATCH-ALL C082S 1/4" SWEAT 9 35.24

SP3078 Sporlan CATCH-ALL C053S 3/8" SWEAT 5 29.43

SP3079 Sporlan CATCH-ALL C083S 3/8" SWEAT 9 35.24

SP3081 Sporlan CATCH-ALL C163S 3/8" SWEAT 16 43.61

SP3085 Sporlan CATCH-ALL C084S 1/2" SWEAT 9 35.75

SP3087 Sporlan CATCH-ALL C164S 1/2" SWEAT 16 47.84

SP3092 Sporlan CATCH-ALL C165S 5/8" SWEAT 16 49.93

Heldon Driers - FlareRealcoldStock No.

Brand Model Size Cu In System Price$ Excl. GST

Liquid Line Driers - Heldon

H0125 Heldon FL 306 3/4" MF 30 108.12

Mueller Driers - SweatRealcoldStock No.

Brand Model Size Cu In System Price$ Excl. GST

Liquid Line Driers - Mueller

H0130 Mueller SD 417 7/8" SWEAT 41 96.90

CD91

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DRIERS

SF Suction Line FiltersThe Sporlan SF Suction Line Filter protects the compressor from dirt. It is designed with an optional relief feature that opens if the filter plugs. It also has a full flow design for low pressure drop. It is suitable for use with all brazing alloys and maximum corrosion resistance.

RealcoldStock No.

Description System Price$ Excl. GST

SP3155 Sporlan Suction Filter SF-285-T 5/8" 101.75

SP3156 Sporlan Suction Filter SF-286-T 3/4" 112.46

SP3157 Sporlan Suction Filter SF-287-T 7/8" 102.82

SP3159 Sporlan Suction Filter SF-289-T 1.1/8" 109.24

SP3161 Sporlan Suction Filter SF-4811-T 1.3/8" 155.30

SP3163 Sporlan Suction Filter SF-4813-T 1.5/8" 166.01

Suction Line Filter DriersThe Suction Line Filter Drier has been specifically designed for system clean-up after a burn out or any time system cleanliness is questionable. High acid and water absorption. For use with HCFCs, HFCs, and lubricants that go with them. Not recommended for permanent use. Once the suction line filter drier has completed its clean-up procedure it should be replaced with a suction line filter.

RealcoldStock No.

Model Description Filter Area Sq. In. Volume Cu. In. System Price$ Excl. GST

Burn-Out Driers

H0305 Virginia WSL-163S 3/8” SW 24 15 37.49

H0306 Mueller A17224 1/2" SW 26 16 37.49

H0308 Mueller A17227 5/8" SW 26 16 32.12

H0311 Micro Guard FDF 264T 1/2" MF 26 16 41.93

H0312 Micro Guard FDF 265T 5/8" MF 26 16 44.12

H0313 Micro Guard FDS 166TT 3/4" SW 26 16 44.72

H0314 Micro Guard FDS 267T 7/8" SW 26 16 44.72

H0315 Micro Guard FDS 269T 1.1/8" SW 26 16 51.89

H0316 Micro Guard FDS 529T 1.1/8" SW 52 30 66.78

Reversible Heat Pump Driers

RealcoldStock No.

Sporlan Code Description System Price$ Excl. GST

SP3240 HPC-103 Heat Pump Drier 3/8” MF 65.66

SP3241 HPC-104 Heat Pump Drier 1/2” MF 67.32

SP3250 HPC-103S Heat Pump Drier 3/8” OD 65.66

SP3251 HPC-104S Heat Pump Drier 1/2” OD 67.32

SP3261 HPC-165SHH Heat Pump Drier 5/8" OD 109.78

Suction Line

CD92

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DRIERS

Refillable Shells - Liquid LineRealcoldStock No.

Model Size Core Max. RatingkW Med Temp

Max. Rating kW Low Temp

System Price$ Excl. GST

Refillable Shells - Liquid Line - Carly

H0135 Carly BCY 485S 5/8" ODS 1 Core 36.0 26.7 246.84

H0139 Carly BCY 487S 7/8" ODS 1 Core 52.2 34.8 238.68

H0140 Carly BCY 967S 7/8" ODS 2 Core 87 52.2 274.38

H0138 Carly BCY 489S 1.1/8" ODS 1 Core 58 41.8 246.84

H0141 Carly BCY 969S 1.1/8" ODS 2 Core 92.3 75.4 274.38

H0143 Carly BCY 9611S 1.3/8" ODS 2 Core 104.4 87 274.38

H0148 Carly BCY 9613S 1.5/8" ODS 2 Core 121.1 107 274.38

H0145 Carly BCY 14413S 1.5/8" ODS 3 Core 177.2 139.1 439.62

H0142 Carly BCY 9617S 2.1/8" ODS 2 Core 159 132.7 274.38

H0146 Carly BCY 14417S 2.1/8" ODS 3 Core 202.1 164.3 428.4

H0149 Carly BCY 19217S 2.1/8" ODS 4 Core 285 223 469.2

SP3405 Sporlan C-485G 5/8" ODS 1 Core 35.2 26.4 356.64

SP3407 Sporlan C-487G 7/8" ODS 1 Core 52.8 35.2 356.64

SP3416 Sporlan C-967G 7/8" ODS 2 Core 87.2 52.8 409.12

SP3408 Sporlan C-489G 1.1/8" ODS 1 Core 52.8 35.2 393.06

SP3462 Sporlan RSF-489T 1.1/8" ODS 1 Core 25.7 9.9 414.48

SP3417 Sporlan C-969G 1.1/8" ODS 2 Core 1/4” FPT connection

101.9 87.9 409.12

SP3463 Sporlan RSF-4811T 1.3/8" ODS 1 Core 31.3 12 315.00

SP3419 Sporlan C-969G 1.3/8" ODS 2 Core 123 87 294.53

SP3113 Sporlan C-14411G 1.3/8" ODS 3 Core 1/4” FPT connection

137.1 123 380.21

SP3420 Sporlan C-9613G 1.5/8" ODS 2 Core 120 106 294.53

SP3429 Sporlan C-14413G 1.5/8" ODS 3 Core 176 123 608.33

Refillable Shells - Suction LineRealcoldStock No.

Model Size Core Max. RatingkW Med Temp

Max. Rating kW Low Temp

System Price$ Excl. GST

SP3464 Sporlan RSF-4813T 1.5/8" ODS 1 core 33.8 12.7 273.11

SP3465 Sporlan RSF-4817T 2.1/8" ODS 1 core 95.0 59.8 259.18

SP3470 Sporlan RSF-9617T 2.1/8" ODS 2 core 102.0 63.3 639.39

SP3466 Sporlan RSF-4821T 2.5/8” ODS 1 core 123.0 80.9 587.98

SP3471 Sporlan RSF-9621T 2.5/8” ODS 2 core 141.0 91.4 615.83

SP3472 Sporlan RSF-9625T 3.1/8” ODS 2 core 193.0 123.0 640.46

Sporlan RSF Suction Driers: kW are based on R404a

CD93

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DirectionalLiquid Line Driers (directional/ bi-directional)

RealcoldStock No.

Model Description System Price$ Excl. GST

H0247 MA Line D111 12 gram XH9 Service Drier 1/4” ODS inlet - capillary connection outlet with separate charging port

9.38

H0250 MA Line D109 10 gram XH9 Service Drier 1/4” ODS inlet - bi-directional 4.39

H0256 MA Line D114 30 gram XH9 Service Drier 5/16” in 1/4” outlet 9.18

Note: Driers with XH9 desiccant are suitable for all refrigerants including blends and R134a

DRIERS

Briquettes To Suit Refillable Shells - InterchangeableRealcoldStock No.

Model Description System Price$ Excl. GST

H0147 Carly CCY 48HP High capacity core for use in systems where high moisture content is suspected.

36.77

H0154 Carly CCY 48N Activated carbon core used for acid wax and varnish removal and clean up in all systems where a burnout has occurred.

47.28

H0156 Carly CCY A48 Screen for Carly liquid line shells. 18.41

SP3702 Sporlan RC-4864 Catch-All core standard. 46.38

SP3703 Sporlan RC-4864-HH Catch-All activated charcoal core. 75.02

SP3704 Sporlan RCW-48 Catch-All High Water capacity core. 84.99

SP3706 Sporlan RC-10098 Catch-All Core 124.24

Refillable Shells - Suction LineRealcoldStock No.

Model Size Core Max. Rating kW System Price$ Excl. GST

H0159 Carly ACY 489S 1.1/8" ODS 1 core 39.4 282.54

H0161 Carly ACY 4811S 1.3/8" ODS 1 core 47.6 295.80

H0163 Carly ACY 4813S 1.5/8" ODS 1 core 58.0 315.18

H0165 Carly ACY 4817S 2.1/8" ODS 1 core 81.2 328.44

H0167 Carly ACY 9617S 2.1/8" ODS 2 core 85.8 375.36

H0169 Carly ACY 4821S 2.5/8" ODS 1 core 109.0 408.00

H0170 Carly ACY 9621S 2.5/8" ODS 2 core 119.5 461.04

H0201 Carly ACY 4825S 3.1/8" ODS 1 core 116.0 436.56

H0202 Carly ACY 9625S 3.1/8" ODS 2 core 167.0 461.04

Suction Line Filter Elements To Suit Above ShellsRealcoldStock No.

Model Description System Price$ Excl. GST

H0150 Carly CCY 48F Micron Filtration (Felt) Suction Line Filter Element 51.00

SP3710 Sporlan RPE-48-BD Pleated Suction Line Filter Element 59.60

AccessoriesRealcoldStock No.

Model Description System Price$ Excl. GST

SP3720 Sporlan A-685 Shell Brackets - suitable for all shells 40.86

SP3725 Sporlan AS-1704 Gaskets suitable only for Sporlan shells 4.07

Note: Carly products are colour coded: Liquid - Red; Suction - Blue; Oil - Grey

Sectional View Dryer Core

CD94

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

DRIERS

Liquid Line Ratings Standard Ratings ASHRAE-ARI: Provides comparison points. This is a basis for drier evaluation at the specified rating condi-tions. This does not determine the performance of a drier over the entire range of possible applications.

Water Capacity: The amount of water (in drops or grams) that a drier will hold at the standard temperatures and equilibrium point dryness (EPD) specified. 20 drops equal 1 gram, which is equivalent to 1 ml or 1cubic cm.

EPD is used to define the lowest possible water content in liq-uid refrigerant attainable by a filter-drier at a specific tempera-ture after it has collected specific quantity of water after equi-librium has been reached between the water in the refrigerant and the water in the drier. EPD is expressed in parts per million (ppm) by weight.

Refrigerant Flow Capacity: The maximum flow of liquid refrigerant that a drier will pass at a 1 psi pressure drop.

The refrigerant flow capacity ratings below are based on 30°C liquid temperature and refrigerant flows of:

6.8 Kg per minute per 3.5 kW for R134a 8.6 Kg per minute per 3.5 kW for R404a 6.1 Kg per minute per 3.5 kW for R410a

6.4 Kg per minute per 3.5 kW for R22 6.4 Kg per minute per 3.5 kW for R407c 9.0 Kg per minute per 3.5 kW for R507

Safety - Based on the drier shell bursting pressure. All liquid line driers must meet the requirements of Underwriters’ Labo-ratories Inc. Standard 207, “Refrigerant Containing Components and Accessories, Nonelectrical” or the fatigue stress analysis per UL 1995.

Selection RecommendationsWater Capacity & Refrigerant Flow: ARI Standard data com-parison for these factors are usually based on flow ratings of an ideal situation of a completely clean system. Flow is reduced as dirt accumulates on the filtering surface.

Filtration: Filter capacity is proportional to filtering area. Filters should be selected with an adequate reserve capacity to allow for the contamination found in most system.

Acid Removal: Acid removal ability is highly recommended.

Final Selection: Should be based on the conditions expected for each job. Extra water capacity and filtering area should also be considered.

Discharge Line MufflersMufflers are designed to eliminate pulsations in the compressor discharge line, and can be mounted in either flow direction, horizontally or vertically.

Mufflers have internal baffles, designed for minimum pressure drop. These baffles change the velocity of the discharge gasses passing through the muffler. This results in a dampening effect on high frequency sound waves in the gasses on high-speed compressors. This also irons out the pulsating waves in low speed compressors.

The muffler is sized to the discharge line of the compressor.

RealcoldStock No.

Model Description System Price$ Excl. GST

F0362 SCY 70S 7/8" ODS 96.70

F0364 SCY 90S 1.1/8" ODS 123.42

F0366 SCY 110S 1.3/8" ODS 127.50

F0370 SCY 130S 1.5/8" ODS 161.16

F0372 SCY 170S 2.1/8" ODS 484.50

DISCHARGE LINE MUFFLERS

CE95

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

Carel Electronic Controls ir33 - New Generation

Following ir32, one of CAREL’s most famous and best selling controllers, the ir300 range represents the maximum technology that CAREL offers in the field of refrigeration applications.

The top-of-the-range model characterising the new series arouses special interest as it can be fitted with all the options available: infrared remote control, programming key, repeater display, high efficiency LED display, HACCP function, real time clock, RS485 serial port, second evapora-tor defrost management, without sacrificing the 4 control relays and the 115 to 230 Vac switching power supply.

All obviously in the same dimensions as the current ir32 case!

Another unique feature concerning this new series of controllers is the possibility to manage smart defrosts, optimising the management of this function, with consequent energy savings.

Finally, one very important aspect involves the IP65 index of protection; the modern technology implemented by CAREL for the moulding of the plastic parts has allowed the protection gasket to be integrated directly into the front panel, without the need to add accessory components to the product that may create an unpleasant aesthetic and visual impact.

ELECTRONIC CONTROLS

Refrigeration ControlsAll models are fitted with a buzzer and can be connected to the Carel Supervisory system (Plant Visor) via the RS485 interface. Please note that Temperature Sensors are not included; please choose the probe that you require from the options below.

RealcoldStock No.

Model Compressor Defrost Fan Aux Infrared Real Time Clock System Price$ Excl. GST

12/24V AC/DC VersionG4501 IR33SOLR00 16A - - - YES - 178.50G4503 IR33COLR00 16A 8A 8A 8A YES - 236.64230V AC VersionG4505 IR33SOER00 8A - - - YES - 183.60G4507 IR33FOER00 8A 8A 5A - YES - 232.56115/230V AC VersionG4509 IR33COHR00 16A 8A 8A 8A YES - 282.54G4511 IR33COHB00 16A 8A 8A 8A YES YES 312.12

Temperature SensorsRealcoldStock No.

Model Description System Price$ Excl. GST

G4550 NTC015WP00 IP68 Immersion sensor 1.5m cable. Temp. range -50 - +100°C 29.99G4552 NTC060WP00 IP67 Immersion sensor 6.0m cable. Max Temp = +100°C 42.02

AccessoriesRealcoldStock No.

Model Description System Price$ Excl. GST

G4302 ABS100/75LG Standard Enclosure W/Cut-out 41.00G4306 87-84315/

RE H95AGEnclosure for All Panel Mount Controllers. Suitable for all standard 70 mm x 28 mm panel mount controllers.

54.11

G4530 IRTRRES000 Remote Control POAG4540 IROPZ48500 RS485 Serial Card POA

230V AC Din Rail Version RealcoldStock No.

Model Description System Price$ Excl. GST

G4512 DN33SOEN00 Carel 230V DIN Rail 1 stage Tstat with static defrost and 16 A relay 225.00G4513 DN33FOEN00 Carel 230V DIN Rail low temp controller with 3 relays 245.00G4536 IRDRDOXIP66 Carel DIN Rail Enclosure 81.60

CE96

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

CONTROL PANELS

Electronic Controllers - Fan Speed Controller - Pressure ActuatedRealcoldStock No.

Model Description System Price$ Excl. GST

Single Phase Controller

G1121 Saginomiya RGE-Z1N4-5 Pressure Actuated Fan speed controllerFactory set for R22, R404a, R407c and adjustable for use with R134a.For approved motors rated from 0.2 - 4 Amps. Single phase.Capillary pressure sensorRange 8 - 28 Bar adjustable4 Bar fixed proportional band

361.08

G1123 Saginomiya RGE-Z1N6-5 Pressure Actuated Fan speed controllerFactory set for R410a Refrigerant.Single Phase, 4 Amps, IP54.

POA

G1124 Saginomiya RGE-Z1Q4-5 Pressure Actuated Fan speed controllerFactory set for R22, R404a, R407c Refrigerants adjustable for use with R134a. Single Phase, 8 Amps, IP54.

481.44

Note: Refer to “CT” section for Mechanical Thermostats

Control Panels

CF97

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FANS

Fan MotorsRealcoldStock No.

Watts Rpm Shaft Mounting/Models

System Price$ Excl. GST

D0121 4 2400 3/16” 2 bolt 50 mm spacing 98.00

D0122 7 1300 D.Plate 3 bolt rear 66.00

D0165 10 1300 D.Plate 3 bolt rear 59.00

D0123 10 1300 D.Plate 4 bolt 78.00

D0124 16 1300 D.Plate 4 bolt Rondo 140-700 CM 77.00

D0162 20 1300 5/16" 3/4 bolt front/rear 132.00

D0125 25 1300 D.Plate Rear Tapped 4 Bolt 99.81

D0129 25 1300 8 mm 3 bolt rear 2 bolt bottom 150.00

AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

D0240 Capacitor 5 mfd suits D0230, D0231 POA

D0241 Capacitor 12.5 mfd suits D0232 POA

Features & Benefits

• Motors Single Phase 50/60Hz (Check first)

• CCW = Counter Clockwise - Facing Shaft

• CW = Clockwise Facing Shaft

• Note: 3 bolt mount 70 mm PCD - 4 bolt mount 54 mm PCD

Bi Directional Fan MotorsRealcoldStock No.

Watts Rpm Shaft Mounting/Models

System Price$ Excl. GST

D0160 40 1300 5/16" 3/4 bolt front and rear 117.00

D0133 60 1300 5/16" 3/4 bolt front and rear 176.00

D0137 90 1440 1/2" 120 x 216 Base - complete 424.00

D0231 230 950 1/2" Foot Mount - 6 Pole POA

D0232 600 900 1/2" Clamp - 1 speed RAC POA

D0134* 180 1400 1/2" Clamp - 3 speed POA

D0169 180 1380 1/2" Clamp bracket POA

* Three Phase

CF98

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FAN MOTOR ASSEMBLY

External Rotor Motor TypeRealcoldStock No.

Brand Description Diameter (mm)

Watts Rpm ApplicationInduce/Blower

System Price$ Excl. GST

Diameter 300 mm

R0930 EBM 300 mm Fan Motor Assembly 1 phase

300 80 1380 Induce 260.00

R0930B EBM 300 mm Condensor Fan Motor Assembly 75W 1 phase CW

300 75 1250 Blower 260.00

Diameter 400 mm

R0940 EBM 400 mm Fan Motor Assembly 1phase

400 180 1380 Induce 429.00

R0940B EBM 400 mm Fan Motor Assembly 1 phase

400 180 1380 Blower 429.00

Diameter 450 mm

EBM 450 mm Condensor Fan Motor Assembly 450W 1 phase

450 450 1325 Induce 600.00

Diameter 500 mm

R0950 EBM 500 mm Fan Motor Assembly 1 phase

500 420 1300 Induce 745.00

Diameter 630 mm

R0963 EBM 630 mm Fan Motor Assembly 3 phase

630 880 1320 Induce 1,007.76

Compact Fan Motor Assembly - Computer Rooms etc.RealcoldStock No.

Brand Description Diameter (mm)

Watts Rpm ApplicationInduce/Blower

System Price$ Excl. GST

D0150 EBM Motor Assembly - fan and guard. 172 x 150 x 55 mm

150 45/39 2800 Induce POA

D0152 EBM 28W Motor Assembly - fan and guard. 172 x 150 x 38 mm

150 29 2800 Induce POA

D0154 EBM 19W Motor Assembly - fan 120 x 120 x 38 mm

120 19 2650 Induce POA

Blade & Motor Type - 3 Piece Fan AssemblyRealcoldStock No.

Brand Description Diameter (mm)

Watts Rpm ApplicationInduce/Blower

System Price$ Excl. GST

D0200 Supco SM672 Universal Motor Kit - Single Speed Bi Directional c/w 2 blades and accessories

100/138 5 3000 Induce/ Blower

51.00

Fan Motor Assembly

CF99

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FANS

Fan BladesRealcoldOr der No.

Description System Price$ Excl. GST

Diameter Blade Pitch Rotation Min. Watts Bore

Induced Type

D0105 178 mm Postmix 5 40° CCW 7 Driveplate 36.41

D0106 200 mm (8”) 5 40° CCW 10 Driveplate 30.37

D0107 229 mm Skope/Cyclone 5 40° CCW 22 Driveplate 36.41

D0111 200 mm (7.7/8”) 5 28° CCW 5 Driveplate 27.58

D0109 254 mm (10”) 5 30° CCW 22 8 mm 34.76

D0118 254 mm (10”) 5 25° CCW 10 Driveplate 34.22

D0115 305 mm (12”) 3 20° CCW 22 Driveplate 33.68

D0117 356 mm (14”) 3 25° CCW 60 5/16" 97.08

D0119 381 mm (15”) 4 35° CCW 120 1/2" 128.52

Reverse Pitch (Blower Type)

D0309 254 mm (10”) 5 30° CCW 22 8 mm 37.54

Miscellaneous Fan Blades

D0015 100 mm (4”) 5 Plastic 30° CW Blower

4 1/8" 7.07

D0027 125 mm (5”) 5 Plastic 25° CW Blower

4 3/16" 6.00

M0165 862-022Y-1 (10”) 5 Plastic 30° CW Blower

20 5/16" 28.71

M0166 862-717Y (7”) 3 Plastic 25° CCW Induced

4 3/16" 20.99

Fan Blades To Suit RAC Condensers (indent only)RealcoldStock No.

Description System Price$ Excl. GST

D0235* 16” suits RAC 5800, 7300 D POA

D0236* 20” suits RAC 10500, 14000, 17000 D POA

D0237* 26” suits RAC 20000, 25000, 30000, 40000, 55000, 70000, 80000 D POA

* Indent items

D0105

D0116

CF100

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

Brass Fittings - FlareRealcoldStock No.

Description System Price$ Excl. GST

Flare Nuts

J0401 1/4" FF 2.09

J0402 5/16" FF 5.36

J0403 3/8" FF 2.75

J0404 1/2" FF 4.08

J0405 5/8" FF 5.81

J0406 3/4" FF 9.18

Reducing Flare Nuts

J0421 3/8" MF - 1/4" Tube 3.11

J0422 1/2" MF - 3/8" Tube 5.51

J0423 5/8" MF - 1/2" Tube 5.92

Male Flare Union

J0431 1/4" MF x 1/4" MF 1.43

J0432 5/16" MF x 5/16” MF 4.03

J0433 3/8" MF x 3/8" MF 2.55

J0434 1/2" MF x 1/2" MF 3.37

J0435 5/8" MF x 5/8" MF 5.41

J0436 3/4" MF x 3/4" MF 14.74

Double Flare Reducing Unions

J0452 3/8" MF x 1/4" MF 3.57

J0454 1/2" MF x 1/4" MF 6.68

J0456 1/2" MF x 3/8" MF 8.82

J0459 5/8" MF x 3/8" MF 9.54

J0460 5/8" MF x 1/2" MF 11.07

J0464 3/4" MF x 1/2" MF 14.74

J0465 3/4" MF x 5/8" MF 20.50

Male Flare - Female Flare. Reducing Unions c/w Gaskets

J0472 1/4" MF x 3/8" FF 4.13

J0474 1/4" MF x 1/2" FF 9.95

J0486 3/8" MF x 1/4" FF 4.59

J0475 3/8" MF x 1/2" FF 5.76

J0488 1/2" MF x 3/8" FF 9.74

J0479 1/2" MF x 5/8" FF 18.41

J0491 5/8" MF x 1/2" FF 6.53

Swivel Unions

J0541 1/4" FF Connectors 9.23

J0543 3/8" FF Connectors 9.23

J0544 1/2" FF Connectors 11.07

J0545 5/8" FF Connectors 13.16

Female Flare Connectors

J0551 1/4" FF c/w Gaskets 5.87

J0553 3/8" FF c/w Gaskets 12.65

J0554 1/2" FF c/w Gaskets 11.58

RealcoldStock No.

Description System Price$ Excl. GST

Male Flare - Male Pipe Unions

J0501 1/4” MF - 1/8” MP 1.53

J0501A 5/16” MF - 1/8” MP 5.20

J0502 1/4” MF - 1/4” MP 2.55

J0502A 5/16” MF - 1/4” MP 8.67

J0504 1/4” MF - 3/8” MP 2.96

J0507 3/8” MF - 1/8” MP 2.96

J0508 3/8” MF - 1/4” MP 2.96

J0510 3/8” MF - 3/8” MP 2.96

J0511 3/8” MF - 1/2” MP 4.49

J0515 1/2” MF - 1/4” MP 8.52

J0517 1/2” MF - 3/8” MP 3.62

J0518 1/2” MF - 1/2” MP 4.49

J0523 5/8” MF - 3/8” MP 7.80

J0524 5/8” MF - 1/2” MP 4.95

J0525 5/8” MF - 3/4” MP 6.38

J0530 3/4” MF - 1/2” MP 15.76

J0531 3/4” MF - 3/4” MP 15.25

Male Flare - Female Pipe Unions

J0536 1/4” MF - 1/8” FP (Gauge Fitting)

1.94

J0535 3/8” MF - 1/2” FP (Gauge fitting U0210)

11.58

J0537 1/4” MF - 1/4” FP 2.65

J0538 1/4” MF - 3/8” FP 10.10

J0539 1/4” MF - 3/4” FP (Cyl. Adaptor)

14.74

J0540 3/8” MF - 3/4” FP (Cyl. Adaptor)

8.36

Acme Adaptor

J0742 1/4" FF - 1/2" Male Acme

6.99

J0743 1/2" Female Acme - 1/4" MF

19.38

J0744 14mm Male - 1/4” MF (Suits Auto A/C Couplers)

6.27

Thread Sealants

N0058 Nylog Blue 30ml POE Oil Sys

20.10

N0059 Nylog Red 30ml Mineral Oil

20.10

N0063 Leak-Lock Tube 39ml 9.80

N0065 Leak-Lock Brush Top 21.15

N0069 Teflon Thread Seal Tape

3.60

Note: MP and FP are NPT (National Pipe Thread).

CF101

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

Brass Fittings - FlareRealcoldStock No.

Description System Price$ Excl. GST

Double Flare Elbows

J0561 1/4" Male Flare 6.63

J0563 3/8" Male Flare 9.38

J0564 1/2" Male Flare 10.10

J0565 5/8" Male Flare 17.90

J0566 3/4" Male Flare 29.43

Male Flare - Male Pipe Elbows

J0590 1/4" MF x 1/8" MP 5.61

J0591 1/4" MF x 1/4" MP 5.61

J0592 1/4" MF x 3/8" MP 6.99

J0594 3/8" MF x 1/4" MP 6.99

J0595 3/8" MF x 3/8" MP 6.99

J0596 3/8" MF x 1/2" MP 10.10

J0598 1/2" MF x 1/4" MP 10.10

J0599 1/2" MF x 3/8" MP 11.07

J0600 1/2" MF x 1/2" MP 11.07

J0601 5/8" MF x 1/2" MP 18.92

J0604 3/4" MF x 3/4" MP 28.41

Male Flare Tees

J0610 1/4" MF 5.61

J0612 3/8" MF 14.74

J0613 1/2" MF 18.41

J0614 5/8" MF 21.01

J0615 3/4" MF 41.00

Male Flare - Male Pipe Tees

J0617 1/4" MFx1/4" MFx1/8" MP

6.83

J0618 1/4" MFx1/4" MFx1/4" MP

6.83

J0619 3/8" MFx3/8" MFx1/4" MP

8.62

Flare Seal Plugs

J0690 1/4” MF 1.43

J0691 5/16” MF 8.36

J0692 3/8" MF 2.40

J0693 1/2" MF 6.63

J0694 5/8" MF 7.80

J0695 3/4" MF 9.23

RealcoldStock No.

Description System Price$ Excl. GST

Pipe Plugs

J0731 1/4" MP 2.24

J0732 3/8" MP 4.79

J0733 1/2" MP 4.34

Pipe Bushings

J0750 1/4" MPx1/8" FP 1.33

J0752 3/8" MPx1/4" FP 7.29

J0754 1/2" MPx3/8" FP 7.91

J0756 3/4" MPx1/2" FP 9.74

J0739 1/8" MPx1/8" FP Elbows

6.94

J0740 1/4" MPx1/4" FP Elbows

4.13

Flare Seal Caps

J0770 1/4” Flare 1.12

J0771 5/16” Flare 3.57

J0772 3/8" Flare 1.99

J0773 1/2" Flare 2.45

J0774 5/8" Flare 3.57

Copper Flare Bonnets

J0790 1/4” Bonnet 1.07

J0791 5/16” Bonnet 1.94

J0792 3/8” Bonnet 1.07

J0793 1/2” Bonnet 1.58

J0794 5/8” Bonnet 1.94

J0795 3/4” Bonnet 3.57

Copper Flare Gaskets

J0810 1/4" Gasket 0.56

J0811 5/16” Gasket 1.63

J0812 3/8" Gasket 0.87

J0813 1/2" Gasket 0.92

J0814 5/8" Gasket 1.02

J0815 3/4" Gasket 2.70

Note: MP and FP are NPT (National Pipe Thread). Refer to CC63 for Thread Sealants.

CF102

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

Copper FittingsRealcoldStock No.

Description R410a System Price$ Excl. GST

Copper Elbows - 45°, Sweat

J0993 5/8" ü 1.73

J0994 3/4" ü 4.64

J0995 7/8" ü 3.01

J0998 1.1/8" 7.55

J0999 1.3/8" 11.58

J1000 1.5/8" 13.16

J1001 2.1/8" 22.08

J0988 2.5/8" 48.35

J0989 3.1/8" 86.70

Copper Elbows - 90°, Sweat

J1002 1/4" x 90° ü 2.24

J1003 3/8" x 90° ü 2.30

J1004 1/2" x 90° ü 1.89

J1005 5/8" x 90° ü 1.73

J1110 3/4" x 90° ü 3.72

J1111 7/8" x 90° ü 4.28

J1113 1.1/8" x 90° 6.17

J1114 1.3/8" x 90° 8.87

J1115 1.5/8" x 90° 13.67

J1116 2.1/8” x 90° 26.27

J1117 2.5/8" x 90° 46.77

J1118 3.1/8" x 90° 68.29

Copper Elbows - 45°, Sweat, Long Radius

J8046* 1.1/8” x 45° lr ü 20.50

J8049* 1.3/8” x 45° lr ü 26.27

J8051* 1.5/8” x 45° lr ü 48.35

Copper Elbows - 90°, Sweat, Long Radius

J1154 1/2" x 90° lr ü 2.50

J1155 5/8" x 90° lr ü 3.32

J1156 3/4" x 90° lr ü 4.18

J1157 7/8" x 90° lr ü 6.43

J8019 1.1/8” x 90° lr ü 21.78

J1159 1.1/8" x 90° lr 9.08

J8020A 1.3/8" x 90° lr ü 24.74

J1161 1.3/8" x 90° lr 15.76

J8023A 1.5/8" x 90° lr ü 35.24

J1163 1.5/8" x 90° lr 25.25

J1165 2.1/8” x 90° lr 38.91

J1167 2.5/8” x 90° lr 82.52

J1169 3.1/8” x 9° lr 146.88

RealcoldStock No.

Description R410a System Price$ Excl. GST

Copper Return Bends - 180°, Sweat

J1120 3/8" x 180° ü 4.95

J1121 1/2" x 180° ü 6.17

J1122 5/8” x 180° ü 13.16

J1123 3/4" x 180° ü 22.59

J1123D 7/8" x 180° ü 23.15

J1125 1.1/8" x 180° 36.26

J1126 1.3/8" x 180° 45.75

J1127 1.5/8" x 180° 53.60

J1128 2.1/8" x 180° 129.54

Copper Tees - Sweat

J1133 1/4" ü 2.14

J1134 3/8" ü 3.16

J1135 1/2" ü 3.37

J1136 5/8" ü 2.09

J1137 3/4" ü 7.34

J1138 7/8" ü 6.89

J8104 1.1/8” ü 28.41

J1140 1.1/8" 12.65

J1141 1.3/8" 21.57

J1142 1.5/8" 28.41

J1144 2.1/8" 57.27

J1145 2.5/8" 80.94

J1146 3.1/8" 197.88

Copper Couplings (rolled stop)

J1203 3.8" ü 0.71

J1204 1/2" ü 1.33

J1205 5/8" ü 0.82

J1206 3/4" ü 2.14

J1207 7/8" ü 1.48

J8133A 1.1/8" ü 5.66

J1209 1.1/8" 3.11

J8136 1.3/8" ü 15.76

J1211 1.3/8" 5.41

J8138A 1.5/8" ü 17.90

J1212 1.5/8" 6.99

J1213 2.1/8" 12.09

J1214 2.5/8" 30.50

J1215 3.1/8" 39.93

* R410a compatible.

CF103

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS & FASTENERS

Fittings & FastenersRealcoldStock No.

Description R410a System Price$ Excl. GST

Copper Reducing Bushes

J1308 3/4" x 1/2" ü 4.95

J1309 3/4" x 5/8" ü 3.62

J1312 7/8" x 1/2" ü 3.42

J1311 7/8" x 5/8" ü 2.60

J1310 7/8" x 3/4" ü 2.81

J8192A 1.1/8" x 5/8" ü 7.65

J1312B 1.1/8" x 5/8" 5.10

J1314 1.1/8" x 3/4" 4.54

J8199A 1.1/8" x 7/8" ü 6.89

J1313 1.1/8" x 7/8" 4.18

J1319 1.3/8" x 5/8" 7.60

J8204A 1.3/8" x 7/8" ü 12.09

J1318 1.3/8" x 7/8" 7.60

J1317 1.3/8" x 1.1/8" 7.60

J1322 1.5/8" x 7/8" 9.79

J1321 1.5/8" x 1.1/8" 9.79

J8217* 1.5/8" x 1.3/8" ü 11.58

J1320 1.5/8" x 1.3/8" 8.57

J1326 2.1/8" x 1.1/8" 38.91

J1325 2.1/8" x 1.3/8" 18.92

J1324 2.1/8" x 1.5/8" 17.90

J1330 2.5/8" x 1.3/8" 38.35

J1332 2.5/8" x 1.5/8" 27.85

J1329 2.5/8" x 2.1/8" 31.52

J1331 3.1/8" x 2.5/8" 47.84

Larger fitting sizes fit into a bend, tee or coupling, smaller fitting sizes fit over OD tube.

Copper Caps

J1345 5/8" ü 1.94

J1346 3/4" ü 4.69

J1347 7/8" ü 1.38

J1351 1.1/8" 2.91

J1353 1.3/8" 4.28

J1355 1.5/8" 6.27

J1361 2.1/8" 14.23

J1366 2.5/8" 35.24

J1367 3.1/8" 79.36

RealcoldStock No.

Description R410a System Price$ Excl. GST

Copper ‘P’ Traps

J1498 5/8" ü 23.15

J1499 3/4" ü 27.34

J1500 7/8" ü 29.99

J1501 1.1/8" 44.68

J1502 1.3/8" 59.93

J1503 1.5/8" 92.46

J1504 2.1/8" 163.20

Copper Saddles (single)

J2010 1/4” 1.07

J2011 3/8” 1.07

J2012 1/2” 1.12

J2013 5/8” 1.07

J2014 3/4” 1.12

J2015 7/8” 1.33

J2017 1.1/8” 1.99

J2018 1.3/8” 2.35

J2019 1.5/8” 2.70

J2020 2.1/8” 3.06

Pipe Clamps (brass)

J1249 for 5/8" OD tube 6.48

J1250 for 7/8" OD tube 7.29

J1251 for 1.1/8" OD tube 8.72

J1252 for 1.3/8" OD tube 8.67

J1253 for 1.5/8" OD tube 11.58

J1254 for 2.1/8" OD tube 12.65

J1255 for 2.5/8" OD tube 17.34

J1257 Brass Plate tapped to 10 mm

3.47

J1258 Screwed Brass Rod 10 mm x 610 mm long

22.59

J1259 Brass Nut 10 mm (for locking rod)

1.07

Note: MP and FP are NPT (National Pipe Thread). Refer to CC63 for Thread Sealants.

* R410a compatible

CF104

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS & FASTENERS

RealcoldStock No.

Description System Price$ Excl. GST

ZP Threaded Rod (galvanised)

J1260 10 mm x 1000 mm 4.44

J1262 10 mm Nut to suit 0.46

J1263 10 mm x 32 mm ZP Washer

0.41

Simplefix Multi Purpose - Pipe Support Systems

J1265 Simplefix 100 m ZP Backing Plate

1.84

J1270 Simplefix Strap (galv.) 25 metre x 0.6 mm

55.69

J1271 5 metre x 0.6 mm 13.67

J1275 Rubber Insertion Strip 5 metre coil

18.92

J1279 Top Bracket 0.82

J1278 Clip Lock 0.51

Fittings & FastenersRealcoldStock No.

Description System Price$ Excl. GST

Simplefix Tube Hangers Hinged

J1701 Hinged 1/2-5/8 3.06

J1702 Hinged 5/8-3/4 3.21

J1703 Hinged 7/8 3.42

J1704 Hinged 1.1/8 3.67

J1705 Hinged 1.3/8 3.98

J1706 Hinged 1.5/8 4.49

J1708 Hinged 2.1/8 6.12

J1710 Hinged 2.5/8 7.50

J1713 Hinged 3.1/8 11.58

Simplefix Tube Hangers Heavy Duty

J1720 Heavy Duty 3/8-1/2 3.06

J1721 Heavy Duty 1/2-5/8 3.06

J1722 Heavy Duty 3/4 3.21

J1723 Heavy Duty 7/8 3.42

J1724 Heavy Duty 1.1/8 3.67

J1725 Heavy Duty 1.3/8 3.98

J1726 Heavy Duty 1.5/8 4.49

J1728 Heavy Duty 2.1/8 6.12

J1730 Heavy Duty 2.5/8 7.50

J1733 Heavy Duty 3.1/8 8.67

Realcold offer a comprehensive range of screws and fastenings. Visit your store to view the full range.

Fasteners - Cable TiesRealcoldStock No.

Description Quantity Per Pack System Price$ Excl. GST

H0084 2.5 x 100 mm Natural 100 0.15

H0085 2.5 x 100 mm Black 100 0.15

H0086 3.5 x 150 mm Natural 100 0.20

H0087 3.5 x 150 mm Black 100 0.20

H0088 4.6 x 200 mm Natural 100 0.26

H0089 4.6 x 200 mm Black 100 0.26

H0090 4.6 x 385 mm Black 100 0.36

H0091 4.6 x 385 mm Natural 100 0.36

H0094 7.6 x 390 mm Natural 100 0.51

H0095 7.6 x 390 mm Black 100 0.51

H0096 7.6 x 465 mm Natural 100 1.02

H0097 7.6 x 465 mm Black 100 1.07

H0098 7.6 x 760 mm Black 50 1.94

CF105

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

Thermoplastic - NylonRealcoldStock No.

Description Recommended max. safe working load

System Price$ Excl. GST

Threaded Rod

J3010 Nylon Threaded Rod M10 x 1.0 metre 80 Kg 15.25

J3012 Nylon Threaded Rod M12 x 1.0 metre 120 Kg 17.90

Buffalo Panel Bolts

J3180 Nylon Panel Bolts M10 x 150 mm 80 Kg 6.43

J3182 Nylon Panel Bolts M10 x 250 mm 80 Kg 7.55

J3190 Nylon Panel Bolts M12 x 150 mm 120 Kg 7.09

J3192 Nylon Panel Bolts M12 x 250 mm 120 Kg 8.87

Full Hexagonal Nuts

J3040 Nylon Full Hex Nuts M10 80 Kg 0.66

J3042 Nylon Full Hex Nuts M12 120 Kg 0.77

Washer Faced Nuts

J3060 Nylon Washer Faced Nut M10 0.71

J3062 Nylon Washer Faced Nut M12 0.87

Dome Nuts

J3080 Nylon Dome Nut M10 80 Kg 0.71

J3082 Nylon Dome Nut M12 120 Kg 1.07

Buffalo T-Nut

J3160 Nylon T-Nut M10 80 Kg 11.07

J3162 Nylon T-Nut M12 120 Kg 15.76

Washer - Standard

J3110 Nylon M10 Washer 10.5 mm ID x 21.0 mm OD x 2.0 mm Thick 0.31

J3112 Nylon M12 Washer 13.0 mm ID x 24.0 mm OD x 2.5 mm Thick 0.31

Washer - Load Bearing

J3130 Nylon M10 Washer 10.5 mm ID x 45 mm OD x 4.5 mm Thick 1.73

J3131 Nylon M10 Washer 10.5 mm ID x 75 mm OD x 4.5 mm Thick 4.28

J3142 Nylon M12 Washer 13.0 mm ID x 50 mm OD x 4.5 mm Thick 1.84

J3143 Nylon M12 Washer 14.0 mm ID x 75 mm OD x 4.5 mm Thick 4.28

Mushroom Head Bolts - (coolroom bolts)

J1285 Mushroom Head Bolt M16 x 250 mm 3.16

J1287 Mushroom Head Bolt M16 x 300 mm 4.44

J1290 Nylon Nut M16 1.22

J1292 Nylon Washer M16 0.82

Threaded Rod

Mushroom Head Bolt

Buffalo T-Nut

Buffalo Panel Bolt

Dome Nut

Washer Faced Nut

CF106

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

Evaporator Mounting Kits - NylonRealcoldStock No.

Model Contains Recommended max. safe working load

System Price$ Excl. GST

Bluemay Kits

J3210 Bluemay Chiller 4 Bolt Kit

Bolt - 10 mm diameter and 150 mm length

4 x J3040 nut

4 x J3060 washer faced nut

4 x J3130 washer

4 x J3180 bolt

320 Kg 39.42

J3212 Bluemay Freezer Kit 4 Bolt Kit

Bolt - 10 mm diameter and 250 mm length

4 x J3040 nut

4 x J3060 washer faced nut

4 x J3130 washer

4 x J3182 bolt

320 Kg 43.61

J3211 Bluemay Chiller 6 Bolt Kit

Bolt - 10 mm diameter and 150 mm length

6 x J3040 nut

6 x J3060 washer faced nut

6 x J3130 washer

6 x J3180 bolt

480 Kg 57.78

J3213 Bluemay Freezer 6 Bolt Kit

Bolt - 10 mm diameter and 250 mm length

6 x J3040 nut

6 x J3060 washer faced nut

6 x J3130 washer

6 x J3182 bolt

480 Kg 65.69

• The use of steel or brass nuts with Thermoplastic rod is not recommended.

• See technical data for temperature limitations. Not recommended for below -30ºC.

• Care should be taken not to over-tighten nuts when used with Thermoplastic threaded rod. Nuts should be tightened by hand and given half a turn with a spanner.

Features & Benefits

Nylon threaded rod and Buffalo bolts, together with associated products, have been at the heart of Bluemay’s manufacturing operation since 1973. This very special range is widely held in high regard by customers who have come to rely on its exceptional qualities and high standard of production.

Threaded Rod, Thermoplastic Nuts and Washers are available in Nylon 66, one of the strongest grades of engineering plastic. This remarkable material has many features, including a melting point of 260˚C, a tensile strength at 23˚C of 62-83 N/mm², and a 1-3% deformation under load 14N/mm² after 24 hours, at 50˚C.

The products in the Bluemay range are:

• Efficient thermal and electrical insulators

• Non-corrosive

• Lightweight and easy to handle

• Hygenic

CF107

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

InsulclampTube and pipe support. INSULCLAMP - effective pipe support and good isolation properties reduce transmission of vibration and noise. Withstands temperatures from -30ºC to +125ºC, good resistance to oil, UV rays etc.

RealcoldStock No.

Size Description Sold Per System Price$ Excl. GST

“A” (mm) “B” (mm)

J1602 1/4" 31.80 7.9 each 3.37

J1603 3/8” 34.93 19.05 each 3.47

J1604 1/2” 38.10 23.81 each 3.47

J1605 5/8” 42.75 25.40 each 3.62

J1606 3/4” 44.45 30.16 each 3.67

J1607 7/8” 49.21 33.34 each 3.77

J1608 1.1/8” 53.98 36.51 each 4.13

J1609 1.3/8” 60.33 44.45 each 4.44

J1610 1.5/8” 73.03 53.98 each 5.56

J1611 2.1/8” 88.90 68.26 each 7.45

J1612 2.5/8” 101.60 80.96 each 11.58

J1613 3.1/8” 114.30 93.66 each 13.16

J1614 4.1/8" 139.70 146.05 each 15.25

J1620 40 x 20mm Aluminium Channel 1 metre lengths length 19.99

Studding ClipThe Studding Clip is a plastic clip for supporting copper tube or PVC pipe.

RealcoldStock No.

Description Sold Per System Price$ Excl. GST

J1681 22 mm Studding Clip each 1.55

J1682 25 mm Studding Clip each 1.60

J1684 32 mm Studding Clip each 1.70

AC1205 Galvanised steel channel 3 metre length M1000 69.36

BBJ Pipe FittingsRealcoldStock No.

Description Height Width Depth Approx Pipe Size + Insulation

System Price$ Excl. GST

J1650 BBJ Suspender # 2 75 mm 55 mm 35 mm 5/8” gas, 3/8” liquid 6.48

J1651 BBJ Suspender # 3 87 mm 62 mm 35 mm 7/8” gas, 1/2” liquid 6.63

J1652 BBJ Suspender # 4 100 mm 70 mm 35 mm 1.1/8” gas, 5/8” liquid 6.73

J1660 BBJ Griplock # 1 30 mm 54 mm 1/2” gas, 1/4” liquid 3.62

J1661 BBJ Griplock # 2 32 mm 60 mm 5/8” gas, 3/8” liquid 3.62

J1662 BBJ Griplock # 3 37 mm 67 mm 7/8” gas, 1/2” liquid 3.77

J1663 BBJ Griplock # 4 46 mm 80 mm 1.1/8” gas, 5/8” liquid 4.13

J1670 BBJ Pipe Tie Base BH1 6.17

J1671 BBJ Pipe Tie Base BH2 6.38

J1672 BBJ Pipe Tie Base BH3 6.58

J1674 BBJ Pipe Tie 250 mm 3.11

J1675 BBJ Pipe Tie 300 mm 3.32

J1676 BBJ Pipe Tie 350 mm 3.57

J1677 BBJ Pipe Tie 400 mm 4.54

J1678 BBJ Pipe Tie 450 mm 4.95

CF108

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

FITTINGS

LocksetsRealcoldStock No.

Model Description System Price$ Excl. GST

V0116 Efco style R5710 is supplied complete with strike. Lockable handle. 167.28

V0121 Efco style R5612 complete with internal release. Adjustable strike, offset 16 to 32mm

231.54

V0300 Shineyear CH1178 complete with internal release. Adjustable strike, offset 45 to70 mm

188.70

V0356 Shineyear Internal Release Mechanism to suit CT/CH-1178 29.43

V0302 Shineyear CH-1200P Edgemount type. Adjustable strike, offset 18 to 22mm 28.92

HingesRealcoldStock No.

Model Description Approx.Overall Length

AdjustableOffset

System Price$ Excl. GST

V0151 Efco R40 110 mm 19 - 25 mm 43.61

V0146 LH Self Closing Rising Hinge (Same as Efco R187 24.17

V0147 RH Self Closing Rising Hinge (Same as Efco R187) 24.17

V0316 Shineyear CH1450 250 mm 32 - 50 mm 81.96

V0318 Shineyear CH1460 250 mm 32 - 60 mm 87.77

V0320 Shineyear CH1470 335 mm 40 - 70 mm 107.10

Style Spares - EfcoRealcoldStock No.

Description System Price$ Excl. GST

V0117 Efco R5722 strike for R5712 and R5710. Adjustable offset 19 to 25 mm 35.24

V0122 Efco R5622 strike for R5612. Adjustable offset 0 to 16 mm 147.90

V0124 Efco R5612 Internal Release Handle for R5612 47.28

V0126 Efco V26A Push Rod for R5612 19.99

V0128 Efco Spring to suit R5612 9.08

V0116

V0121

V0300

V0151

V0146V0316

Accessories - Efco

A. V0126

B. V0124

C. V0129

D. V0117

E. V0122/3

A

C

B

E

D

CH109

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

HEAT EXCHANGERS

Doucette Heat ExchangersNominal capacities kWs at +5°C SST 5.5K of subcooling for below heat exchangers

RealcoldStock No.

Model Description System Price$ Excl. GST

Nom. HP R22 R404a R134a Connection Sizes Dimensions (mm)Diam. x Length

Liq. Vol. cm³

Suction Liquid

F0045 SLHE 1 1 4.52 3.17 4.09 5/8" SW 3/8" SW 28 344 44 POA

F0046 SLHE 1.1/2 1.1/2 6.30 4.20 5.83 7/8" SW 3/8" SW 35 363 52 POA

F0048 SLHE 3 3 8.21 4.69 7.59 1.1/8" SW 1/2" SW 42 375 58 POA

F0049 SLHE 5 5 14.51 9.67 12.85 1.3/8" SW 5/8" SW 54 356 255 POA

F0050 SLHE 7.1/2 7.1/2 17.79 11.43 15.19 1.5/8” SW 5/8" SW 54 425 306 POA

• Doucette Heat Exchangers are all copper construction, suitable for all refrigerants. Type L copper fluted suction tubes.

• Single and multiple tube configurations to reduce velocity and pressure drop. High temperature brass brazed. UL listed

Working Principle:

Wilchwitzer Thermo-Technik (WTT) consists of a pack of pressed stainless steel plates which are brazed together with 99.9% copper in a vacuum furnace. When assembling the pack every alternate plate is rotated by 180° to produce two separate flow channels in which the heat exchange media flow in opposite directions. All contact points are joined by brazing. This process makes it possible to achieve very high mechanical strength, i.e. high pressure resistance. The corrugated plates generate high turbulence during fluid through put, which promotes efficient heat exchange even with a low flow rate.

Applications: WTT can be utilized for a wide range of gaseous and non clogging liquid media: Water; Oil; Glycol; Freons. Typical applications include:

• Floor Heating • Condensers and evaporators in Chillers & Heatpumps• Industrial processes• Hydraulic oil cooling• Heat Recovery• Desuperheaters

Advantages:

• Compactunit,lowweight • Highoperationaltemperaturesandhighworkingspressures.• Lessspacerequired • SUS316(AISI316)(W-1.4401)stainlesssteelforeffectivecorrosionresistance.• Nogaskets,noleaks • Easyinstallationandreplacement,lowmaintenancerequirements.• High heat transmission rate

Heat Exchangers

CI110

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

INSULATION

Tube InsulationRealcoldStock No.

Description Lengths Per Ctn System Price$ Excl. GSTID Wall Thickness

Inches mm Inches mm

N4109FR 3/8" 9 1/2" 13 70 5.13N4113FR 1/2" 13 1/2" 13 60 6.66N4116FR 5/8" 16 1/2" 13 50 8.37N4119FR 3/4" 19 1/2" 13 40 9.12N4122FR 7/8" 22 1/2" 13 32 10.16N4125FR 1” 25 1/2" 13 30 9.99N4128FR 1.1/8" 28 1/2" 13 28 11.60N4135FR 1.3/8" 35 1/2" 13 20 13.04N4142FR 1.5/8" 42 1/2" 13 18 14.94N4148FR 1.7/8" 48 1/2" 13 16 17.32N4154FR 2.1/8" 54 1/2" 13 14 17.90N4160FR 2.3/8" 60 1/2" 13 12 19.60N4167FR 2.5/8" 67 1/2" 13 10 24.83N4180FR 3.1/8" 80 1/2" 13 8 29.54N4190FR 3.1/2” 90 1/2" 13 8 28.69N4209FR 3/8" 9 3/4" 19 32 7.25N4213FR 1/2" 13 3/4" 19 32 9.36N4216FR 5/8" 16 3/4" 19 28 12.11N4219FR 3/4" 19 3/4" 19 24 11.89N4222FR 7/8" 22 3/4" 19 20 14.43N4228FR 1.1/8" 28 3/4" 19 18 19.33N4235FR 1.3/8" 35 3/4" 19 16 22.63N4242FR 1.5/8" 42 3/4" 19 12 22.61N4248FR 1.7/8" 48 3/4" 19 10 31.17N4254FR 2.1/8" 54 3/4" 19 8 28.63N4260FR 2.3/8" 60 3/4" 19 8 32.00N4267FR 2.5/8" 67 3/4" 19 8 34.91N4276FR 3” 76 3/4" 19 6 40.20N4280FR 3.1/8" 80 3/4" 19 6 41.07N4290FR 3.1/2" 90 3/4" 19 6 46.19N4319FR 3/4” 19 1” 25 18 23.88N4322FR 7/8" 22 1" 25 16 27.69N4328FR 1.1/8" 28 1" 25 12 25.02N4335FR 1.3/8" 35 1" 25 10 29.37N4342FR 1.5/8" 42 1" 25 8 33.26N4348FR 1.7/8" 48 1" 25 8 37.82N4354FR 2.1/8" 54 1" 25 8 53.92N4360FR 2.3/8” 60 1" 25 6 46.09N4367FR 2.5/8" 67 1” 25 6 49.66N4380FR 3.1/8" 80 1” 25 6 59.05

Maxflex™ is made from light weight elastomeric material specially designed for thermal insulation usage. Maxflex™ is CFC free, HCFC free, ODP zero, asbestos free, dust free and fibre free. The molecular structure of Maxflex™ is characterized by a large number of fine cross-linked closed cells which provides:

a) Stable and low thermal conductivity value (K-Value).

b) Excellent moisture and vapour resistance due to its dense surface skin and the closed cell structure.

c) Outstanding ozone / UV and weather resistance.

d) Flexibility, making installation work easy and neat.

e) Ideal thermal insulation to prevent condensation problems on chilled water pipes or refrigerant lines, and also prevents frost formation.

Maxflex™ retards heat loss from dual temperature piping systems, reduces noise by acting as a vibration damper and serves as an outer shield to protect metal pipes from corrosion by atmospheric and industrial environment. Maxflex™ complies with ASTM C 534-88.

CI111

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

INSULATION

Sheet InsulationRealcoldStock No.

Description System Price$ Excl. GST

N4513FR 1.22m x 0.914m x 13 mm 20 sheets/ctn 33.47

N4519FR 1.22m x 0.914m x 19 mm 10 sheets/ctn 50.62

N4525FR 1.22m x 0.914m x 25 mm 8 sheets/ctn 68.27

1 Metre Adhesive InsulationRealcoldStock No.

Description System Price$ Excl. GST

N2491FR 1.00 m x 6 mm 1 metre length 37.64

N2493FR 1.00 m x 13 mm 1 metre length 43.15

Roll InsulationRealcoldStock No.

Description System Price$ Excl. GST

N4406FR 1.00 m x 22.0 m x 6 mm Rolls 508.62

N4413FR 1.00 m x 11.0 m x 13 mm Rolls 473.33

N4419FR 1.00 m x 7.0 m x 19 mm Rolls 428.16

N4408FR 1.00 m x 22.0 m x 6 mm Roll - Adhesive 827.97

N4415FR 1.00 m x 11.0 m x 13 mm Roll - Adhesive 567.63

Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.

SpecificationsPhysical Properties Maxflex Test Method

Cell Structure Closed Cell -

Density Ibs/ft³ (g/cm³) 3-6 (0.048-0.096) ASTM D 1667

Thermal Conductivity BTU. in/ft² hr. °F(W/mK)

Mean Temp. -4°F (-20°C)

32°F (0°C)

75°F (24°C)

90°F (32°C)

104°F (40°C)

ASTM C177

JIS A1412

DIN 52613K-Value 0.22 0.032

0.23 0.034

0.25 0.037

0.26 0.038

0.27 0.039

Service Temperature -70°F to 257°F

-57°C to 125°C

Maxflex becomes hard at -57°C

But can be used even at -200°C

Water Vapour Permeability (kg/Pa.s.m) 0.10 perm-in (0.15 x 10-12) ASTM C 355

ASTM E96

Moisture Resistance (μ value) μ not less than 5000 DIN 52615

Water Absorption (weight %) Not more than 3% ASTM D 1056

Ozone Resistance No crack ASTM D 1171

Heat Stability (% shrinkage) At 200 °F and 220 °F for 7 days

4.5 and 5.5 respectively ASTM C 534

Flammability & Smoke Density Class VO UL–94

Self-extinguishing ASTM D 635

Class 1 BS476 Part 7 1987

Class 0 BS476 Part 6 1987

Smoke density 80 ASTM-E84 (15 mm thick)

U.V Weather Resistance Excellent -

Nitrosamine Contents Not detected U.S FDA

Flexibility Excellent -

CI112

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

INSULATION

Insulation TapeRealcoldStock No.

Description System Price$ Excl. GST

N4606FR Maxflex Foam Tape

Closed cells elastomeric, black colour, one side adhesive with protective film. Used for hot and cold pipe insulation. Can be used as joint protection.

48 mm x 15 metres roll - self adhering

38.48

Electrical Insulation TapeRealcoldStock No.

Description System Price$ Excl. GST

N0185 Insulation Tape - 48 mm x 30 metres roll - self adhering Black PVC 9.89

N0186 Insulation Tape - 48 mm x 30 metres roll - self adhering White PVC 10.40

N0187 Insulation Tape - 48 mm x 30 metres roll - self adhering PVC (heavy grade) 17.34

N0420 Electrical Tape 19 mm x 20 metres Black 1.68

N0421 Electrical Tape 19 mm x 20 metres Red 1.68

N0422 Hellerman Electrical Tape 19 mm x 20 metres Yellow 1.68

N0423 Electrical Tape 19 mm x 20 metres Blue 1.68

N0424 Hellerman Electrical Tape 19 mm x 20 metres Green 1.68

Duct TapeRealcoldStock No.

Description System Price$ Excl. GST

N0402 Aluminium Duct Tape - 51 mm x 45.72 metres roll 18.41

N0404 Silver Duct Tape - 51 mm x 54.86 metres roll 18.41

Petroleum TapeRealcoldStock No.

Description System Price$ Excl. GST

N0406 Denso Tape 50 mm x 10 metres roll 15.25

N0407 Denso Tape 100 mm x 10 metres roll 25.45

Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.

CI113

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

INSULATION

Accessories, Sealing, Jointing CompoundsRealcoldStock No.

Description Sold Per System Price$ Excl. GST

Insulation Adhesive

N0180 Virginia KMP Adhesive for tube insulation. 236ml Tin 26.27

N0170 Holdfast H2 Insulation Adhesive for tube insulation. 125ml Tin 15.56

N0172 Holdfast H2 Insulation Adhesive for tube insulation. 250ml Tin 20.50

Sealing Compounds

N0512 Holdfast Bison Silicone Sealant (White) 375ml Tube 21.47

N0515 Holdfast Fix all 220 Sealant White 425g Tube 27.34

N0519 Holdfast Silaseal Silicone Sealant (Clear) 310ml Tube 23.56

N0190 Holdfast Nailpower FR Expanding Foam 750ml Aerosol Can 47.28

N0191 Holdfast Foam Cleaner 500ml Aerosol Can 25.25

N0192 Holdfast Spare Nozzle Pack of 4 5.25 per pack

Polyurethane Foam

N0197 Endurathane is a low density, flame retardant, rigid polyurethane foam system kit, consisting of 1kg tin of each component ‘A’ and ‘B’. When mixed together at optimum temperature, will yield a total of approximately 56.6 litres (0.057m³).

2 X 1Kg Tins A + B

96.70

N0198 Endurathane (as above) 2 x 5kg components. Will yield 283 litres (0.28m³)

2 X 5Kg Tins A +B

327.42

Thermal Mastic

N0020 Presstite Thermal Mastic 3.8 Litre Tin 90.37

N0021 Presstite Thermal Mastic 225gm Tube 20.50

Note: A heat conducting compound - increases heat transfer at four times the rate obtained with mechanical mounting.

Insulation Mastic

N0025 Virginia PM11 Insulation Mastic

Weatherproof, stops surface condensation, reduces heat transfer & conductivity

3.8 Litre Tin 128.00

Dektite Pipe Flashing - Square BaseDektite provides a durable maintenance-free seal, no matter what profile or diameter pipe

RealcoldStock No.

Model Description Sold Per System Price$ Excl. GST

N0500 DB0-35 Mini Dektite Ideal for cable or conduit 20 per carton, each 18.41

N0501 DB5-55 Dektite to 55 mm 10 per carton, each 20.50

N0502 DB50-70 Dektite to 70 mm 10 per carton, each 22.08

N0503 DB70-110 Dektite 50 - 120 mm 10 per carton, each 33.10

N0504 DB110-160 Dektite 110 - 170 mm 10 per carton, each 35.75

N0505 DB160-220 Dektite to 220 mm 10 per carton, each 65.18

N0506 DB220-300 Dektite 160 - 300 mm 10 per carton, each 102.46

N0521 RF801G Round Base Dektite 20 - 70 mm Retrofit: for existing and fixed piping

10 per carton, each 45.19

N0495 Top-Hat Roof penetration kit 87.55

Note: Material Safety Data Sheets are available, upon request, for hazardous substances.

N0020

N0025

N0512

N0021

N0502

CL114

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

LUBRICANTS

Compressor LubricantsRealcoldStock No.

Type Description System Price$ Excl. GST

Mineral Oil

N0531 Suniso 3GS (150 VIS) Mineral Oil - 3.8 Litre Container. Low/Medium Temp 49.64

N0535 Suniso 3GS (150 VIS) Mineral Oil - 19 Litre Container Low/Medium Temp 234.55

N0541 Suniso 4GS (300 VIS) Mineral Oil - 3.8 Litre Container Medium/High Temp 49.64

N0545 Suniso 4GS (300 VIS) Mineral Oil - 19 Litre Container Medium/High Temp 234.55

N0551 Suniso 5GS (500 VIS) Mineral Oil - 3.8 Litre container Suitable for Tecumseh CG, York F210R, Sanden. Automotive/Marine

51.89

Guide: 150 SUS 32 cST, hence Suniso 3GS (150) and Clavus G32

300 SUS 68 cST, hence Suniso 4GS (300) and Clavus G68

Polyolester Oil

N0579 Emkarate LE 32MAF Polyolester Oil - 19 Litre Low/Medium Temp 989.40

N0580 Emkarate LE 32MAF Polyolester Oil - 3.8 Litre Low/Medium Temp 240.98

N0581 Emkarate LE 32MAF Polyolester Oil - 0.95 Litre Low/Medium Temp 64.26

N0582 Emkarate RL 68H Polyolester Oil - 0.95 Litre Medium/High Temp 64.26

N0583 Emkarate RL 68H Polyolester Oil - 3.8 Litre Medium/High Temp 244.19

N0584 Emkarate RL 100S Polyolester Oil - 0.95 Litre Automotive/Marine 59.06

Vacuum Pump LubricantsThis is a specially selected oil with a low vapour pressure and high stability for sealing.

RealcoldStock No.

Type Description System Price$ Excl. GST

N0105 Yellow Jacket Vacuum Pump Oil - .47L 13.28

N0106 Yellow Jacket Vacuum Pump Oil - .95L 24.31

N0108 Yellow Jacket Vacuum Pump Oil - 3.8 L 83.33

Note: Compressor lubricants are not suitable for vacuum pumps. Material Safety Data Sheets are available, upon request, for hazardous substances.

Oil PumpRealcoldStock No.

Type Description System Price$ Excl. GST

T2162 Yellow Jacket 77940 Max-Flow Combination Suction/Discharge Pump.

Suits all containers

290.24

T2164 Yellow Jacket 77930 Max Flow Deluxe Pump 352.36

T2640 Yellow Jacket 77931 O Ring Kit for Max Deluxe 20.99

Oil InjectorRealcoldStock No.

Type Description System Price$ Excl. GST

T2160 Yellow Jacket 69562 Oil Injector. 118ml (4oz) . 1/4” MF x 1/4” FF Quick Connector 215.27

Frascold OilsRealcoldStock No.

Type Description System Price$ Excl. GST

C5860 SZ-OIL1 FC300 19 Litre Oil (M/T R404) POA

C5862 SZ-OIL3 FC170 19 Litre Oil (L/T R404a) POA

C5864 SZ-OIL2 FC170 25 Litre Oil (L/T, M/T R22) POA

C5866 T00WK110 Oil Filter Kit POA

CL115

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

LUBRICANTS

Lubricants - Quick Reference ChartAshrae Number Brand Name Part Number Lubricant Type

R11 Replacement

R123 - N0541 Mineral/ Alkylbenzene Blend HCFC

R12 Replacements

R134a - N0581 P.O.E HFC

R401a Suva MP 39 N0531 Mineral/ Alkylbenzene Blend HCFC

R401b Suva MP 66 N0531 Mineral/ Alkylbenzene Blend HCFC

R401c Suva MP 52 N0531 Mineral/ Alkylbenzene Blend HCFC

R405a G2015 N0531 Mineral or Alkylbenzene PFC

R406a GHC-X3 N0531 Mineral HCFC

R409a FX 56 N0531 Mineral HCFC

R413a Isceon 49 N0581 P.O.E PFC

R414a GHG-X4 N0531 Mineral HC

R414b Hotshot N0531 Mineral HC

R502 Replacements

R409b FX 57 N0531 Mineral HCFC

R412a TP 5R N0581 P.O.E PFC

R290 Care 40 N0531 Mineral HC

R507 AZ 50 N0581 P.O.E HFC

R402a HP 80 N0531 Mineral/ Alkylbenzene Blend HCFC

R402b HP 81 N0531 Mineral/ Alkylbenzene Blend HCFC

R403a 69S (RX) N0581 P.O.E PFC

R403b 69L (RX1) N0581 P.O.E PFC

R404a HP 62 N0581 P.O.E HFC

R407a Klea 60 N0581 P.O.E HFC

R407b Klea 61 N0581 P.O.E HFC

R408a FX 10 N0531 Mineral HCFC

R411b G2018B N0531 Mineral HC

R509a TP5R2 N0581 P.O.E PFC

R22 Replacements

R407c Forane 407c N0581 P.O.E HFC

R410a AZ 20 N0581 P.O.E HFC

M059 Isceon 59 - R417a Mineral/ P.O.E/ Alkylbenzene HC

M099 Isceon 99 - R438a Mineral/ P.O.E/ Alkylbenzene HCFC

Hydrochlorofluorocarbon = HCFC

Hydrofluorocarbon = HFC

Perfluorocarbon = PFC

Hydrocarbon = HC

CO116

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

OIL CONTROL SYSTEMS

Trax Oil Control SystemsRealcoldStock No.

Description System Price$ Excl. GST

F0092 TRAX TR3201 Oil Level Control System 540.86

Oil Reservoir And AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

F0052 Henry S-9130 Adjustable Oil Level Regulator with 3/8” MF SAE equalisation connection 90 psi max. differential. Replaces S9191, S9131, S9134, S9133, S9190, & S9193

532.29

F0053 A C & R S-9108 Oil Reservoir (4 US gallon capacity) 15 litres

The oil reservoir is the holding vessel for stand-by oil necessary for the operation of the oil control system.

712.22

F0055 A C & R S-9109 Oil Reservoir (2 US gallon capacity) 7.5 litres 3/8 Flare Rotalock Valve

525.86

F0057 Henry S-9104 Reservoir Pressure Valve 3/8 Flare Connections

This valve will maintain a 5lb. positive pressure differential at the oil reservoir over the crankcase pressure ensuring an adequate oil supply to the oil level regulator.

115.67

F0062 Henry S-9104H High Pressure Check Reservoir Valve

Some parallel compressor systems have a satellite compressor which maintains a higher suction pressure than the other compressor system. The S-9104H provides a 20 lb positive pressure in the oil reservoir for this application.

115.67

F0058 Henry S-9241 Oil Level Regulator Shut-Off Valve 3/8 MF x 3/8 FF Swivel Connection S-9106-vertical mount

This valve allows each oil level regulator to be isolated if service is required on a compressor. Vertical model. For equalization lines on S-9130 regulator.

83.33

F0060 Henry 3/033/212 Sight Glass Adaptor 3 bolt 1.7/8 to suit Copeland 8R Series, Frascold W Series

153.15

F0059 A C & R S-9105 Oil Line Strainer 3/8 MF Flare- 100 Mesh 11 sq in.

This strainer protects the oil level regulator by removing foreign matter. The strainers mesh screen provides adequate straining with low pressure drop.

87.18

F0063 Rotolock Valve 3/8 - To suit A C & R reservoirs 45.26

F0066 *Henry S-4005 POE Oil Filter Drier 3/8” MF. 6 micron filtration

Removes foreign material from the oil as it passes through the filter.

255.97

F0067 Henry S-9106H Horizontal Shut-Off Valve

3/8” MF x 3/8” FF, swivel connection. Horizontal model for use where space is limited.

83.33

* Note S-4005 oil filter drier must be fitted between oil separator and crankcase, or between oil separator and reservoir on multiple compressor systems

Oil Control AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

SP2600 Sporlan OF-303 Oil Filter 3/8" Flare 291.31

SP2601 Sporlan OF-303-BP Oil Filter W/Bypass 3/8" Flare 317.02

SP2650 Sporlan S-OL Oil Sight Glass 968013 39.73

F0052

F0059

F0067

F0058

F0057/62

F0053/5

F0066

CO117

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

OIL SEPARATORS

Carly TurboilRealcoldStock No.

Model Conn. ODS Maximum Refrigerating Capacity in kW Oil Pre-Charge Litre

System Price$ Excl. GST

R134a R22 R404a

-5°C -5°C -40°C -5°C -40°C

F0400 1503S 3/8" SW ODF Solder 5 7 5 7 5 0.3 288.66

F0401 1504S 1/2" SW ODF Solder 5.5 8 6 8 6 0.3 270.30

F0402 2505 S/MMS 5/8" SW ODF Solder 17 24 17 25 17 0.3 270.30

F0404 3007 S 7/8" SW ODF Solder 25 30 24 32 26 0.3 306.00

F0406 3009 S 1 1/8" SW ODF Solder 28 36 28 40 29 0.3 319.26

F0408 3011 S/MMS 1 3/8" SW 31 45 32 47 32 0.3 337.62

F0425 8013 S 1 5/8" SW 70 90 65 94 65 1.0 639.54

F0426 9017 S 2 1/8” SW 80 110 85 120 87 1.0 703.80

F0429 FM 15021 S 2 5/8" SW 146 194 138 200 142 0.4 2,008.38

F0430 FM 30025 S 3 1/8" SW ODF Solder 318 424 303 430 310 0.4 2,107.32

F0450 Float Assembly replacement suits our F0429, F0430, CY33303450 843.54

Temperatures indicated are evaporating temperatures.

The refrigerating capacities indicated take into account a con-densing temperature of 38°C, of a 5°C superheated, of a 5°C subcooled and suction temp of 18°C.

To obtain a condensing temperature which is different to +38°C, apply the following formula:

Po = P / {T - 38) x 0.0143 + 1} (kW)

P = The refrigerating capacity of your installation (kW)

T = The condensing temperature of your installation in °C

Po = The new refrigerating capacity of your installation estimated for a condensing temperature of 38°C

CO118

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

OIL CONTROL SYSTEMS

Oil SeparatorsRealcoldStock No.

Model ODS Nominal Capacity kW * Dimensions (mm)H X D

System Price$ Excl. GST

R22 R404a

-5°C -25°C -5°C -25°C

F0869 S-5581 3/8" 4.7 3.3 4.7 3.3 210 x 102 266.22

F0070 NS-1004 1/2" 6.7 6.0 6.7 6.0 260 x 102 222.36

F0072 NS-1005 5/8” 18.6 17 18 15.8 362 x 102 225.42

F0074 NS-1007 7.8” 27.4 25.7 28.2 25 450 x 102 249.90

F0076 NS-1009 1.1/8” 35.6 33.5 36.8 32.7 533 x 102 277.44

F0078 NS-3011 1.3/8” 46 42.8 46.5 41 540 x 102 374.34

F0080 NS-3013 1.5/8” 61.6 58 63.6 57.5 472 x 153 395.76

F0882 S-5694 2.1/8” 101.7 93.8 103.6 92.5 486 x 158 604.86

Henry Helical Oil Separators/Oil ReservoirsRealcoldStock No.

Model ODS Nominal Capacity kW * Dimensions (mm)H X D

System Price$ Excl. GST

R22 R404a

-5°C -25°C -5°C -25°C

F0347 S-5392 1.5/8" 63.3 56.3 66.8 52.7 890 x 150 1,264.80

F0348 S-5394 2.1/8" 105.5 87.9 109.0 84.4 890 x 150 1,353.54

F0351 S-5302 2.1/8" 123.1 137.1 109.0 144.2 640 x 200 1,382.10

F0352 S-5303 2.5/8" 281.3 249.7 291.9 225.0 750 x 250 1,766.64

* Has removable float assembly

• All capacities shown are based on 37.8°C condensing temperature with an 18.3°C suction gas temperature.

• Dimensions are Height x Diameter in millimetres.

Replacement FloatRealcoldStock No.

Description System Price$ Excl. GST

F0330 A1900-30 Float Assembly suits S-5200 and S1900 series 470.22

F0331 2-023-001 Float Valve Gasket 8.57

AC & R Heater ElementsHeat elements add heat to oil separators to prevent migration of refrigerant to the vessel during off cycles of the compressor. Also suitable for AC & R accumulators.

RealcoldStock No.

Description System Price$ Excl. GST

F0084 S-9111 4” diameter 220 volt 25 Watt

Suits S-5520, S-5180 series oil separators

90.37

F0085 S-9112 6” diameter 220 volt 50 Watt

Suits S-5600, S-5190 series oil separators

96.14

CP119

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

High Pressure ControlsRealcoldStock No.

Model Reset Range(kPa)

Differential(kPa)

System Price$ Excl. GST

Ranco High Pressure

G0053 016-8750 Auto 690 to 3000 250 to 800 123.17

G0054 016-8751 Manual 690 to 3000 320 fixed 144.59

Differential Pressure ControlsRealcoldStock No.

Model Reset Range(kPa)

Differential(kPa)

System Price$ Excl. GST

Saginomiya

G1019 WNS-C106X Auto 50 to 350 50 to 250 190.64

PRESSURE CONTROLS

Dual Pressure ControlsRealcoldStock No.

Model Description System Price$ Excl. GST

Reset Hp/Lp Range Differential

kPa kPa

Ranco Dual Pressure Controls

G0048 017-8711* Auto

Auto

LP

HP

-30 to 700

700 to 3000

62 to 393

345 bar fixed

207.77

G0056 017-8701 Auto

Auto

LP

HP

-30 to 700

700 to 3000

62 to 393

345 bar fixed

161.72

G0055 017-8705 Auto

Manual

LP

HP

-30 to 700

700 to 3000

62 to 393

345 bar fixed

193.85

G0203 Dual Pressure Switch Replacement Cover 20.99

G0204 Single Pressure Switch Replacement Cover 20.45* These Ranco controls are complete with copper capillaries fitted. Refer to Frascold Accessories page for Sealed/Electronic Oil Protection Systems.

Saginomiya Dual Pressure Controls

G1010 DNS-D306XM Auto

Manual

LP

HP

-60 to 600

800 to 3000

60 to 400

Manual reset

141.37

G1015 DNS-D306X Auto

Auto

LP

HP

-60 to 600

800 to 3000

60 to 400

400 bar fixed

137.09

G1016 DNS-D606X* Auto

Auto

LP

HP

-60 to 600

800 to 3000

60 to 400

400 bar fixed

138.16

G1017 DNS-D606XM* Auto

Manual

LP

HP

-60 to 600

800 to 3000

60 to 400

Manual reset

141.37

* 606 series have independent contacts for high and low side.

Low Pressure ControlsRealcoldStock No.

Model Description System Price$ Excl. GST

Reset LP Range Differential

kPa kPa

Ranco Low Pressure Controls

G0044 016-8713* Auto -30 to 700 62 to 393 127.45

G0050 016-8706 Auto -30 to 700 62 to 393 123.17* These Ranco controls are complete with copper capillaries fitted.

Saginomiya Low Pressure Controls

G1000 SNS-C106X Auto -60 to 600 60 to 400 94.89

G1002 SNS-C102X Auto -20 to 200 25 to 150 94.89

G1006 SNS-C110X Auto 100 to 1000 100 to 300 94.89

CP120

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

PRESSURE CONTROLS

Pressure Control AccessoriesRealcoldStock No.

Description System Price$ Excl. GST

G0057 Ranco Angle Bracket to suit pressure controls 7.77

G0058 Shineyear Coupler (capillary and nuts) to suit pressure controls 7.71

G0060 Flica 600 mm Capillary Couplers c/w Nuts 14.35

G0062 Flica 1000 mm Capillary Couplers 16.01

Oil Protection Controls - Differential Pressure Controls (oil failure)COPD = Cut Out Pressure Differential. CIPD = Cut In Pressure Differential

RealcoldStock No.

Model Description Reset System Price$ Excl. GST

Time Delay COPD (bar) CIPD (bar)

G0096 Ranco P30-3601* 60 second 0.3 to 4 0.7 to 4.8 Manual 267.75

G0097 Ranco P30-3701* 90 second 0.3 to 4 0.7 to 4.8 Manual 293.45

G0099 Ranco P30-3801* 120 second 0.3 to 4 0.7 to 4.8 Manual 278.46

* These Ranco controls are complete with copper capillaries fitted.Please refer to Frascold Accessories page for Sealed/Electronic Oil Protection Systems.

Saginomiya Flow SwitchesRealcoldStock No.

Model Description System Price$ Excl. GST

G1090 FQS-U30G Suitable for pipes: 1” to 6”

Connection: 1” NPT

272.03

Pressure Control HosesRealcoldStock No.

Description System Price$ Excl. GST

G0070 12" Hose 1/4" FF x 1/4" FF 90° 29.24

G0071 18" Hose 1/4" FF x 1/4" FF 90° 30.37

G0072 24" Hose 1/4" FF x 1/4" FF 90° 31.49

G0074 36" Hose 1/4" FF x 1/4" FF 90° 38.07

G0075 48" Hose 1/4" FF x 1/4" FF 90° 44.72

G0076 60" Hose 1/4" FF x 1/4" FF 90° 49.64

• These hoses are designed for permanent installation and have a 1/4” FF metal to metal seat. Copper gaskets recommended. Suitable for capillary lines, etc.

• The minimum operating temperatures these hoses can be safely used at is -30°C, and the maximum is 122°C. Maximum pressure rating is 4000 kPa.

Oil Protection Controls

CP121

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

PRESSURE CONTROLS

Pressure Controls - CB Series

• Pressure Control CB series are small disc type pressure controls featuring compact structure and

proven reliability

• They are designed to suit modern designed applications with various types of connection style,

applications include air conditioning, auto industries and others.

• Type ACB - High & Medium pressure range

• Type LCB - Low pressure range

Small Pressure Controls - Type ACB, LCBRealcoldStock No.

Model OFF (PSI) ON (PSI) Colour Life Cycle (Times) System Price$ Excl. GST

G1160 LCB-PA48 6±5 21±7 Blue 10,000 56.10

G1162 LCB-PA95 10±5 25±5 Blue 10,000 56.10

G1164 LCB-PA96 35±7 60±7 Blue 10,000 56.10

G1166 ACB-PA52 150±14 225±14 Red 100,000 56.10

G1168 ACB-PA53 170±14 250±14 Red 100,000 56.10

G1170 ACB-PA55 200±20 259±10 Red 100,000 56.10

G1172 ACB-PB51 410±14 335±14 Black 100,000 56.10

G1174 ACB-PB52 385±14 310±14 Red 100,000 56.10

G1176 ACB-PB111 400±14 300±21 Red 100,000 56.10

G1178 ACB-PB112M 400±28 <300 Manual Red 10,000 81.96

G1180 ACB-PB113 350±10 250±20 Red 100,000 56.10

Conversion Factor: 1 Bar = 14.5 PSI

Electrical RatingsType ACB, LCB Category Of Ratings

M Rating

Rated Voltage (V)Rated Amps. (A)

Power Factor(COSΦ)

125V AC 250V AC 12V DC

Non-Inductive Current 1 1 to 6 1 to 4 1 to 4

Inductive

Current

Full Load

Locked Rotor

0.75

0.45

1 to 24 1 to 16 -Type ACB, LCB

↑: Operating direction on press.

Increase at high press.

M↓: Operating direction on manual reset

Contact Style Connections

Specifications

• Lead wire end: Free

• Contact action: SPST

• Ambient Temperature: -30°C to +100°C

• Fluid Temperature: -54°C to +135°C

Should mark pressure ON/OFF setting on the body

• Pressure Connection: ¼” Female

• Construction: Waterproof

Dimensions

CR122

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

REFRIGERANT

RefrigerantRealcoldStock No.

Product Description Charge Size/ Packaging System Price$ Excl. GST

L0100 R134a Household and commercial refrigeration, automotive, air conditioning and centrafugal water chillers.

Liquid or Vapour 13.5 Kg DAC POA

L0159 Isceon MO59

(R417A)

An easy to use non-ozone depleating retrofit replacement for R22 in DX AC and medium temp commercial refrigeration systems.

Liquid only 11.35 Kg DAC POA

L0199 Isceon MO99 An easy to use non-ozone depleating retrofit replacement for R22 in DX water chillers and industrial/ process cooling applications. No oil change required.

Liquid or Vapour 11.35 Kg POA

L0141 R404a Suitable for LT and MT. Liquid only 10.9 Kg DAC POA

L0145 R507 Low Temperature Refrigerant Liquid only 11.3 Kg DAC POA

L0030 R22* Suitable for A/C, MT and HT. Liquid or Vapour 13.5 Kg DAC POA

L0157 R407c Larger commercial air conditioning systems. Replacement for HCFC 22.

Liquid Only 11.3 Kg DAC POA

L0161 R410a Small to medium commercial air conditioning systems. Alternative to R22 in new equipment.

Liquid Only 11.3 Kg DAC POA

* Note: HCFC refrigerants will be phased out by 2015 in accordance to the Ozone Layer Protection Act 1996.

Refrigerant LevyRealcoldStock No.

Description Size/ Packaging System Price$ Excl. GST

Training Levy All refrigerants per Kg 0.50

Levy All refrigerants containing CFCs or HCFCs per Kg 1.50

Recovery CylindersManufactured to DOT-400 suitable for use with R410a refrigerant

RealcoldStock No.

Description System Price$ Excl. GST

T2490M 10 Kg recovery cylinders 216.00

T2491M 20 Kg recovery cylinders 310.00

Note: Refer to page TD252 for general rules for handling flurocarbon refrigerants. Go to www.realcold.co.nz to download a copy of the MSDS sheet/s.

CR123

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

REFRIGERANT

R22

R502

R717

R744

Tem

p °C

kPA

gps

igkP

Ag

psig

kPA

gps

igkP

Ag

psig

Tem

p °F

-50

-35.

510

.5*

-19

-2.8

-59.

217

.5*

582

84.5

-58

-48

-28.

68.

4*-1

0-1

.5-5

4.3

16*

639

92.7

-54.

4-4

6-2

1.16.

2*-1

-0.1

-48.

914

.4*

700

102

-50.

8-4

4-1

33.

8*8

1.2-4

2.7

12.6

* 76

411

1-4

7.2

-42

-4.2

1.2*

192.

8-3

5.9

10.6

*83

312

1-4

3.6

-40

0.01

0.5

304.

4-2

8.3

8.4*

905

131

-40

-38

101.5

426.

1-2

0.3

6*98

114

2-3

6.4

-36

223.

554

7.8

-11.6

3.4*

1061

154

-32.

8-3

432

4.6

689.

9-2

.1 0

.6*

1145

166

-29.

2-3

250

7.2

8211

.98.

31

1234

179

-25.

6-3

063

9.1

9814

.219

.42.

613

2819

3-2

2-2

880

1211

416

.531

.54.

414

2620

7-1

8.4

-26

9113

132

19.2

44.6

6.7

1592

231

-14.

8-2

410

816

150

21.8

58.6

8.7

1638

237

-11.2

-22

126

1817

024

.773

.811

1751

254

-7.6

-20

145

2119

127

.790

.113

1870

271

-4-1

816

424

213

30.9

108

1519

9428

9-0

.4-1

619

527

236

34.3

126

1821

2430

83.

2-1

420

730

261

37.9

146

2122

5932

86.

8-1

223

133

287

41.7

168

2424

0134

810

.4-1

025

437

314

45.6

191

2825

4937

014

-828

441

343

49.8

215

3127

0339

217

.6-6

310

4537

354

.124

235

2863

415

21.2

-433

448

405

58.8

269

3930

3043

924

.8-2

361

5243

863

.629

943

3204

465

28.4

039

858

473

68.7

328

4832

8547

632

243

062

510

7438

253

3769

547

35.6

446

567

548

79.5

397

5841

8360

739

.26

504

7358

885

.343

363

4630

671

42.8

854

279

630

91.4

473

6951

1174

146

.410

584

8567

397

.751

374

5629

816

5012

622

9071

810

4.2

555

8159

0385

653

.614

668

9776

611

1.260

588

6188

897

57.2

1671

610

481

511

8.3

654

9564

8494

060

.818

769

112

866

125.

770

410

267

9298

564

.420

814

118

920

133.

575

511

071

1410

3268

2286

612

697

514

1.581

111

871

.624

917

133

1033

149.

986

812

675

.226

975

141

1093

158.

693

013

578

.828

1040

151

1155

167.

699

514

482

.430

1107

161

1219

176.

910

6515

486

3211

6516

912

8618

6.6

1130

164

89.6

3412

3017

813

5519

6.7

1203

174

93.2

3613

0018

914

2620

712

7718

596

.838

1378

200

1500

217.

713

6919

910

0.4

4014

4821

015

7722

8.9

1449

210

104

4215

2522

116

5624

0.3

1543

224

107.

644

1610

233

1738

252.

216

3023

611

1.246

1688

245

1823

264.

617

2225

011

4.8

4817

7025

719

1127

7.4

1820

264

118.

450

1855

269

2001

290.

419

1427

812

252

1950

283

2095

304.

120

0529

112

5.6

5420

5029

721

9231

8.1

2110

319

129.

2

(ISCE

ON

49)

(ISCE

ON

59)

(ISCE

ON

69L

)(IS

CEO

N 7

9)

R134

AR4

06A

R409

AR4

13A

R407

CR4

10A

R417

AR4

04A

R507

R408

AR4

03B

R422

ATe

mp

°CkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

g-5

0-7

1-5

09

-25

-23

-12

-23

1-4

8-6

7-4

521

-18

-15

-3-1

712

-46

-63

-39

33-1

1-6

7-8

24-4

4-5

9-3

346

-24

171

35-4

2-5

4-2

717

617

1528

1147

-40

-43

-49

-20

2976

1626

4022

6021

.4-3

8-3

7-4

3-1

241

9329

3953

3473

35.1

-36

-35

-30

-37

-455

111

3752

6746

8849

.6-3

4-2

8-2

4-3

14

6813

049

6682

6010

457

.2-3

2-2

1-1

6-2

314

8115

061

8198

7411

873

.7-3

0-1

4-9

-16

2495

172

7497

114

8913

890

.9-2

8-5

0-7

3411

019

588

114

132

105

157

110.

2-2

63

92

4511

821

910

313

315

112

317

813

0.2

-24

1419

1157

128

245

119

152

171

141

199

141.2

-22

2629

2170

136

273

135

173

193

161

220

163.

3-2

039

4033

8415

630

315

319

521

618

124

318

7.4

-18

4952

4498

177

334

171

219

240

203

267

212.

9-1

659

6557

114

200

367

191

243

265

227

295

240.

5-1

472

7871

130

224

402

211

270

292

251

320

254.

9-1

286

9285

147

249

438

233

297

320

277

348

285.

2-1

010

110

710

016

527

647

725

632

635

030

538

231

6.9

-811

812

311

718

430

451

828

035

738

233

441

235

0.7

-613

514

013

420

433

456

130

539

041

536

444

638

6.5

-415

315

815

222

636

560

733

242

445

039

648

340

5.1

-217

217

717

224

839

865

436

046

048

643

052

044

4.4

019

219

719

227

244

070

438

949

852

546

556

048

5.7

221

121

721

429

750

075

742

053

756

550

260

352

9.2

422

924

023

732

352

981

245

257

960

854

164

457

5.3

625

326

326

235

056

686

948

562

365

258

268

959

9.4

828

328

728

737

960

493

052

066

969

862

573

264

910

313

313

314

409

645

993

557

716

747

670

783

709.

712

342

340

342

441

688

1059

595

766

798

716

831

795.

114

372

368

372

474

732

1128

635

819

851

765

886

854.

416

403

397

404

508

779

1200

676

873

906

816

942

884.

718

436

428

437

544

828

1275

719

929

964

869

998

947.

420

469

461

471

582

880

1353

764

989

1024

920

1057

1013

.522

507

495

507

621

934

1435

811

1049

1087

980

1113

1083

.124

544

530

545

662

990

1520

859

1119

1152

1040

1179

1154

.826

584

567

585

705

1049

1608

910

1179

1221

1100

1244

1192

.728

626

605

626

750

1110

1701

962

1249

1291

1170

1313

1269

.130

668

645

670

796

1175

1797

1016

1329

1365

1240

1388

1349

.832

715

687

715

844

1242

1896

1073

1399

1442

1310

1462

1433

.834

761

730

762

895

1311

2000

1131

1479

1521

1380

1540

1521

.336

811

775

811

947

1384

2108

1192

1559

1604

1460

1620

1566

.838

863

822

863

1001

1460

2220

1254

1639

1689

1530

1700

1659

.840

915

871

920

1057

1539

2336

1319

1729

1778

1610

1784

1756

.342

972

922

970

1115

1621

2456

1386

1819

1870

1700

1872

1857

.544

1029

974

1030

1176

1707

2581

1455

1909

1966

1790

1964

1962

.346

1090

1029

1090

1238

1796

2710

1527

2009

2064

1880

2057

2016

4811

5310

8511

5013

0318

8828

4416

0121

0921

6719

7021

5121

27.6

5012

1711

4412

2013

7019

8529

8316

7722

0922

7320

6022

5022

43.4

5212

8712

0412

9014

4020

8531

2617

5623

1923

8221

6023

5823

6454

1356

1267

1360

1512

2188

3274

1837

2429

2496

2270

2464

2488

.7

Pres

sure

Tem

per

atu

re C

hart

CR124

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

RECEIVERS

Vertical ReceiversRealcoldStock No.

Model Pump Down Capacity Kg @ 80%

Connections PRV Required Yes/No

System Price$ Excl. GST

Sweat Rotalock Valves SuppliedYes/NoR22 R134a R404a

Inlet Outlet Inlet Outlet

D0650 SFRV1 1.4 1.4 1.3 1/4” 1/4” 3/8” ODS 1” N Y POA

F0261 RLVCY15 1.4 1.4 1.3 1/4” 1/4” 3/4” 3/4” N Y POA

F0264 RLVCY30 2.8 2.8 2.4 3/8” 3/8” 3/4” 3/4” N Y POA

F0280 RLVCY40 3.8 3.8 3.3 3/8” 3/8” 3/4” 3/4” N Y POA

F0284 RLVCY60 5.5 5.5 4.9 1/2” 1/2” 1” 1” N Y POA

F0292 RLVCY120M 11.0 11.0 9.8 5/8” 5/8” 1 1/4” 1 1/4” N Y POA

Carly Receivers have fittings for Rotalock valves. Also the same connection allows for a solder connection as above. Gaskets are 3/4”: H1103; 1”: H1104. Mounting is by single M10 stud (F0261-F0280) or M12 (F0284).

Pressure Relief Devices

The requirements for the installation of pressure valves into pressure vessels are proscribed within AS/NZS1677.2.1998 and its amendments.

Viz;

1. Vessels of less than 300L internal gross volume:

• Vessels containing more than 1.5kg of Group B2 refrigerants: or

• 1.0 Kg of Group A3 refrigerants must be fitted with 1 or more mechanical pressure relief devices.

2. Vessels of greater than 300 L internal gross volume:

• Pressure vessels which may contain liquid refrigerant and which may be shut off from other parts of the refrigeration system shall be protected by means of two pressure relief valves.

• If the vessel is on the high pressure side of the system, the pressure relief valves shall be controlled by a changeover device.

Steelfort

CR125

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

RECEIVERS

Horizontal Receivers - Heavy Duty / Large CapacityRealcoldStock No.

Description Pump Down Capacity Kg @ 80%

Connections Dimensions (mm) System Price$ Excl. GST

Inlet Outlet Diameter LengthR134a R22 R404a

C5770 2010TV 33 28 33 1.1/4 SPUD 1.1/4 SPUD 219 1210 POA

C5780 2510TV 55 47 54 1.3/4 SPUD 1.1/4 SPUD 273 1260 POA

C5785 2515TV 81 70 80 1.3/4 SPUD 1.3/4 SPUD 273 1760 POA

C5790 2520TV 107 91 105 1.3/4 SPUD 1.3/4 SPUD 273 2260 POA

C5791 *LR2530 161 160 140 1 3/8” copper 7/8” copper 273 3084.4 POA

C5792 *LR3015 118 117 100 1 3/8” copper 1 1/8” copper 324 1584.4 POA

C5793 *LR3020 154 153 135 1 3/8” copper 1 1/8” copper 324 2084.4 POA

C5794 *LR3520 183 181 160 1 3/8” copper 1 1/8” copper 356 2084.4 POA

C5795 *LR3530 266 264 230 1 3/8” copper 1 1/8” copper 356 3084.4 POA

C5796 *LR4020 243 241 210 1 3/8” copper 1 3/8” copper 406 2084.4 POA

C5797 *LR4030 353 351 305 1 3/8” copper 1 3/8” copper 406 3084.4 POA

C5798 *LR5020 394 391 340 2 5/8” copper 2 1/8” copper 508 2148.0 POA

C5799 *LR5030 570 566 490 2 5/8” copper 2 1/8” copper 508 3146.0 POA

* Note: LR models are available on an Indent only basis, by arrangement.

• Horizontal receivers have 1/2” FNPT socket for pressure relief valve Spud fittings to suit Rotalock multi-directional valves.

• NB: Neither Rotalock nor safety valves are included in these prices. Refer to the Valves Section of this catalogue for these items.

• Capacities listed are based on receiver being 80 percent full with refrigerant temperature of 32°C.

Protection of Pressure Vessels

• All refrigeration systems, excluding self-contained low charge systems, MUST be fitted with pressure relief devices, selected for the refrigerant and operating conditions of the system.

• Relief devices must of a type that automatically reset after activation.

• Receivers that have an internal volume of 300L or more shall be protected by means of 2 pressure relief valves, controlled by a changeover device.

• High side relief to the low side has many attendant risks and the designer of such systems must ensure that the pressure of any part of the system does not exceed the maximum safe working pressure of the vessel – see AS/NZS 1677.2.1998, section 3.1 to section 3.4.

Horizontal ReceiversSteelfort

CS126

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

SIGHT GLASSES

Liquid/Moisture Indicating - CarlyRealcoldStock No.

Description System Price$ Excl. GST

H0751 Carly VCYL 12 1/4" MF 35.75

H0752 Carly VCYL 13 3/8" MF 37.84

H0753 Carly VCYL 14 1/2" MF 41.51

H0754 Carly VCYL 15 5/8" MF 48.86

H0757 Carly VCYL 22 1/4" MF 33.00

H0758 Carly VCYL 23 3/8" MF FF 39.93

H0759 Carly VCYL 24 1/2" MF FF 50.44

H0760 Carly VCYL 25 5/8" MF FF 50.44

H0763 Carly VCYL 32S 1/4" ODS 42.59

H0764 Carly VCYL 33S / MMS 3/8" ODS 44.68

H0765 Carly VCYL 34S 1/2" ODS 45.19

H0766 Carly VCYL 35S 5/8" ODS 50.44

H0767 Carly VCYL 37S 7/8" ODS 80.94

H0768 Carly VCYL 39S 1.1/8" ODS 117.30

Liquid/Moisture Indicating - SporlanRealcoldStock No.

Description System Price$ Excl. GST

SP2718 Sporlan See-All Sight Glass 5/8" ODS 49.11

SP2722 Sporlan See-All Sight Glass 7/8" ODS 71.17

SP2723 Sporlan See-All Sight Glass 1.1/8" ODS 78.34

SP2724 Sporlan See-All Sight Glass 1.3/8" ODS 155.30

SP2728 Sporlan See All Sight Glass SA-217 2.1/8” ODS 224.91

SP2700 Sporlan See-All Sight Glass 1/4" MF 34.76

SP2703 Sporlan See-All Sight Glass 3/8" MF 37.00

SP2710 Sporlan See-All Sight Glass 1/2" MF 46.38

SP2717 Sporlan See All Sight Glass 5/8" MF 48.04

SP2701 Sporlan See-All Sight Glass 1/4" MF FF 36.41

SP2704 Sporlan See-All Sight Glass 3/8" MF FF 38.61

SP2711 Sporlan See-All Sight Glass 1/2" MF FF 47.45

SP2709 Sporlan See-All Sight Glass 5/8” MF FF 56.28

SP2702 Sporlan See-All Sight Glass 1/4" ODS 36.41

SP2705 Sporlan See-All Sight Glass 3/8" ODS 38.61

SP2712 Sporlan See-All Sight Glass 1/2" ODS 48.04

Sight Glasses For Soldering On To PipeRealcoldStock No.

Description System Price$ Excl. GST

H0770 Carly VCYLS 11 1.3/8" SW 59.36

H0771 Carly VCYLS 13 1.5/8" SW 62.02

H0772 Carly VCYLS 17 2.1/8" SW 67.27

H0773 Carly VCYLS 21 2.5/8" SW 67.78

* Note: Listed sight glasses are suitable for all refrigerants except ammonia refrigeration systems. For Ammonia compatible sight glasses, please refer to page IN180.

H0751, H0752, H0753, H0754

H0758, H0759, H0760

H0764, H0765, H0766

H0770, H0771,

H0772, H0773

H0767, H0768

CT127

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TEST EQUIPMENT

Service Manifold SetsMastercool introduces the most advanced and user friendly Digital Manifold on the market today. This manifold offers a large, easy to read LCD that displays Pressures, Saturated Temperatures, Actual Temperatures, Superheat and Subcooling Temperatures for over 60 refrigerants. When used with the clamp-on thermocouple connector, it will display the actual temperature and automatically calculate the superheat or subcool temperature. When the vacuum sensor cable is attached to the manifold it will display deep vacuum. To insure lasting performance and durability the manifold case is constructed of ABS material and protected by a rugged rubber boot.The technician now has a fully functional manifold with the intelligence to quickly access and deliver the accurate information needed to do the job right.

RealcoldStock No.

Model Description Gauges / Hoses Scale System Price$ Excl. GST

Aluminium 4-Way Manifold Gauge Sets

T4110 96203-MB 4W Ball Valve Manifold (80 mm) R22, R134a, R404a bar & psi, °C 390.00

T4111 96203-EB 4W Ball Valve Manifold (80 mm) R22, R404a, R410a bar & psi, °C 390.00

Full 3/8” bore through the block increases; flow considerably, faster charging & recovery. Ball valve rotates 90° between two teflon washers requiring little effort to turn, even under pressure. Opens and closes quickly with only a quarter turn. Knob position shows whether valves are open or closed.

2-Way Aluminium Manifold Piston Valve

T2182M 93103-E 2W Aluminium Manifold R22, R404a, R410a bar & psi, °C 285.00

Mastercool’s 2-Way Manifolds feature free floating piston valve design resulting in less wear and tear in comparison to market standard twisting piston valves. Double O-Ring allows for a much better seal resulting in less leaks.

2-Way Digital Manifold

T2191M 99661 Digital 2W manifold + thermocouple, 3-150 cm

R22, R134a, R404a, R410a

bar & psi, °C, °F, Mpa, Kg/cm²

900.00

Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm hoses, vacuum sensor with cable and clamp-on thermocouple.

4-Way Digital Manifold

T2192M 99961-EU Digital 4 Way Manifold, complete set, 3-150 cm

R22, R134a, R404a, R410a

bar & psi, °C, °F, Mpa, Kg/cm2

1,480.69

T4220 99972 Digital 4W Manifold + thermocouples, 3-180 cm

R22, R134a, R404a, R410a

bar & psi, °C, °F, Mpa, Kg/cm²

1,100.00

Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm (3-180 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, data logger CD and USB cable.

Charging Hoses - Suitable for all CFCs, HCFCs, HFCs & R401aMastercool uses only GRADE 5 HOSE with a selection of Standard and Nylon Barrier for high pressure applications. Knurled brass nuts make finger tightening easy. Crimped with 8 segment dies for secure fit and maximum durability. Hoses are available in sets and a variety of lengths to meet all EPA, SAE and UL requirements for containment of refrigerant.

RealcoldStock No.

Model Description System Price$ Excl. GST

80 mm Standard Gauge

T2240M 47363 Red 90 cm HD 1/4” Hose, nylon barrier 34.17

T2242M 47361 Blue 90 cm HD 1/4” Hose, nylon barrier 34.17

T2244M 47362 Yellow 90 cm HD 1/4” Hose, nylon barrier 34.17

T2246M 47603 Charging hose red, nylon barrier WP 56 bar, L 150 cm 45.19

T2248M 47601 Charging hose red, nylon barrier WP 56 bar, L 150 cm 45.19

T2250M 47722 Charging hose yellow, HD 1/4”, L 180 cm 45.19

T2254M 47721 Charging hose blue, HD 1/4”, L 180 cm 52.02

T2259M 94160 Charging hose black Full Flow 3/8”, L 150 cm 90.37

T2277M 49603-J Charging hose red L244 - 1/2”20 UNF 47.28

T2278M 49601-J Charging hose blue L244 - 1/2”20 UNF 47.28

T2280M 46372 Set of 3-180 cm HD 1/4” hose + automatic shut-off valve 127.50

Charging Hoses

CT128

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TEST EQUIPMENT ACCESSORIES

GaugesRealcoldStock No.

Model Description Suitable for Refrigerants

Scale System Price$ Excl. GST

80 mm Standard Gauge

T2217M EBH High Pressure Gauge (80 mm) R22, R404a, R410a bar & psi, °C 52.53

T2218M MRBH High Pressure Gauge (80 mm) R22, R134a, R404a bar & psi, °C 52.53

T2219M MRBL Low Pressure Gauge (80 mm) R22, R134a, R404a bar & psi, °C 52.53

T2229M EBL Low Pressure Gauge (80 mm) R22, R404a, R410a bar & psi, °C 52.53

63 mm Standard Gauge

T2222M MRH High Pressure Gauge (63 mm) R22, R134a, R404a bar & psi, °C 44.17

T2210M MRL Low Pressure Gauge (63 mm) R22, R134a, R404a bar & psi, °C 44.17

T2223M MH High Pressure Gauge (63 mm) R22, R134a, R404/7 bar, °C 44.17

Accessories

T2233M 91553-E Gauge Protection Set (80 mm) 36.77

T2234M 93553-E Gauge Protection Set (63 mm) 33.66

T2236M 98251-E Replacement Lens for (80 mm) GGE 12.09

CouplersRealcoldStock No.

Model Description Suitable for Refrigerants

Scale System Price$ Excl. GST

Airconditioning (R410A) Couplers

T2711M 90413 R410A Adapter - 1/2”20UN F swivel nut x 1/4” 44.68

Automotive (R134a) Couplers

T2307M 82834-E Service coupler HS R134a manual 1/4” FL-M x 16 mm 99.81

T2308M 82934-E Service coupler LS R134a manual 1/4” FL-M x 13 mm 99.81

Access Port Core Remover

T2290M 91496 Valve core access tool w/access port 136.68

T4050 91490 Standard Valve Core Remover/Installer 1/4” 80.00

T4060 91498 Valve core remover/installer, incl. for R410A 150.90

Imperial Kwik - Couplers

T0092 16C Kwik-Coupler Model 16C Straight Coupler (45° Flare 1/4” Female x 1/4” Male) 69.87

T0093 15140 Kwik-Coupler Model 17C 90° Coupler (45° Flare 1/4” Female x 1/4” Male) 87.77

T0093A 65155 & 65153

Gasket Set for above Kwik-Couplers 3.88

T0095 26C Kwik-Couplers Straight 5/16” 113.22

T0097 27C Kwik-Couplers 90° Coupler 5/16” 112.20

CT129

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TEST EQUIPMENT

Recovery SystemMastercool introduces its newest addition to the recovery machine lineup. Taking the reliability of the 69000 series machines, Mastercool has enhanced those features to allow for maximum recovery capacity while at the same time decreasing size and weight. The design of the new double piston compressor and cooling by the largest fan and condenser in the market makes the new 69300 series the most complete solution to your recovery needs.

RealcoldStock No.

Model Description System Price$ Excl. GST

T2380M 69300-220 TWIN TURBO Refrigerant Recovery unit 220V-50/60 Hz 2,601.00

Specifications Recovery Rate Operating Temperature Weight Dimensions in mm

1/2 Hp oil less compressor

Direct vapour up to .39 Kg/min 0 to 50 °C 11 Kg 457 (L) x 254 (W) x 356 (H)

Direct liquid up to 3.1 Kg/min

Push pull up to 8.1 Kg/min

Recovery CylindersRealcoldStock No.

Model Description System Price$ Excl. GST

T2490M 62010 12,5 L recovery cylinder tank 216.00

T2491 63010 27,2 L recovery cylinder tank 310.00

Vacuum PumpsA good quality vacuum pump is an integral tool for complete A/C service. Mastercool vacuum pumps are durable and time tested. They stand up to the most grueling conditions and will provide years of reliable service. Mastercool offers a complete selection of pumps. Regardless of your service requirements, Mastercool has a model for your application.

RealcoldStock No.

Model Description System Price$ Excl. GST

T4240 90060-220-AUS Vacuum pump 220V/50Hz 35 Ltr/min 2 stage 500.00

T2400M 90065-220 Vacuum pump 220V/50Hz 119 Ltr/min 2 stage 1,101.60

T2402M 90067-220 Vacuum Pump 220V/50Hz 178 Ltr/min 2 stage 1,269.90

Model No. of Stages

Ultimate Vacuum

Motor Pump Speed Electrical Specs Shipping Weight

Dimensions in cm

90060-220 2 25 Microns 1/6 Hp 2850 RPM 220 V/50 Hz 5.40 Kg 29.5 x 11.5 x 21.5 x 18

90065-220 2 25 Microns 1/3 Hp 1425 RPM 220 V/50 Hz 15.0 Kg 37 x 15.5 x 27.5 x 24

90067-220 2 25 Microns 1/2 Hp 1425 RPM 220 V/50 Hz 15.40 Kg 41 x 15.5 x 27.5 x 24

CT130

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TOOLS

Other Test Equipment Digitial Vacuum Gauge is packaged in blow molded case. It is a hand held unit that uses thermocouple technology. This vacuum gauge has been designed with the technician’s field environment in mind, allowing for self-calibration and a sensor that will not be damaged by small mists of oil. This unit allows for a target vacuum range (20,000 to 1 micron) to be programmed with a light sensor indicator. Now you have the freedom to continue with your other work and come back to the system once you see the indicator light signaling your target vacuum.

RealcoldStock No.

Model Description System Price$ Excl. GST

Electronic Vacuum Gauge

T2435M 98061 Electronic thermocouple vacuum gauge 591.60

Charging Equipment

T2100M 98230 Electronic charging module for 98210 & 98210-A 365.70

T2370M 98211-A Accu-Charge II - Charging Scale, programmable 727.26

Leak Detectors

T2323M 55500-220 Heated sensor electronic leak detector w/220V battery charger 1,045.50

T2326M 55500-SEN Sensor for 55500 121.38

T4210 55100 Electronic leak detector 1,010.00

Mastercool ToolsRealcoldStock No.

Model Description System Price$ Excl. GST

Tube Cutters

T4025 70027 Mini tube cutter for 1/8” to 5/8” OD tubing 25.00

T2000M 70029 Mini tube cutter for 3/8” to 1 1/8” OD tubing 49.42

T2004M 70033 Heavy duty tube cutter 1/8 to 1-1/8” OD tubes 89.30

T4020 70035 Heavy duty tube cutter 1/4 to 1-5/8” OD tubing 48.00

Tube Deburring Tool

T2089M 71685 Pencil type reamer - metal 28.41

Tube Expander Kit

T2035M 71600 Hydra-swage tube expander kit - 7 heads 3/8” - 1 1/8” 820.00

Flaring & Swaging Tools

T4000 70048 Set of 5 swaging punches 50.00

T4010 70053 Flaring and swaging kit (275) 1/8” to 3/4” 200.00

Ratchet Wrenches

T2046M 70082 Refrigeration ratchet wrench 1/4”, 3/8”, 3/16”, 5/16” sq 47.84

CT131

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TOOLS

Flaring & Swaging ToolsRealcoldStock No.

Model Brand Description System Price$ Excl. GST

T2020 60440 Yellow Jacket Flare/Swage Kit 3/16” to 3/4” OD 367.20

T2022 60210 Yellow Jacket Flaring Kit 3/16” to 5/8” OD 90.88

T2024 60270 Yellow Jacket Flare/Burnish Kit 3/16” to 5/8” OD 181.56

T2034 60461 Yellow Jacket Swage Set with Clamping Bar 3/16” to 5/8” OD 162.18

T0742 CH-806A Shine Year Flaring Tool 1/4” to 3/4” OD 160.14

T2022

CH-806A

Tube Cutter Spares - Yellow Jacket®

RealcoldStock No.

Model Description System Price$ Excl. GST

T2502 60100 Cutter Wheel for 60101, 60102, 60103 15.76

T2504 60124 Cutter Wheel for 60139 23.15

T2506 60147 Cutter Wheel for 60146 29.99

T2516 60127 Wheel Screw for 60123 (New) 2.40

T2517 60172 Handle Screw for 60139 7.45

T2526 60079 Wheel Pin & Clip for 60101, 60102, 60103 8.67

T2528 60144 Wheel Pin & Clip for 60142 4.59

T2531 60140 Screw/Retainer for 60139 11.07

T2538 60095 Reamer Screw & Washer for 60101, 60102, 60103 11.58

Tube Cutter Spares

CT132

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TOOLS

Tube Benders (lever type) RealcoldStock No.

Model Brand Description System Price$ Excl. GST

T2084 60380 Yellow Jacket for 7/8" Tube - Bending Radius 3" 528.36

T0701 CH-364-04-1/4 Shine Year for 1/4" OD tube 48.96

T0703 CH-364-06-3/8 Shine Year for 3/8" OD tube 66.30

T0704 CH-364-08-1/2 Shine Year for 1/2" OD tube 78.29

T0705 CH-364A-10-5/8 Shine Year for 5/8" OD tube 104.04

T0706 CH-364-12-3/4 Shine Year for 3/4” OD Tube 124.00

T0710 CH-367 Shine Year for 1/4”, 5/16”, 3/8” OD tube, 11/16 radius to centre, 180° bender

30.50

Bending Springs RealcoldStock No.

Model Brand Description System Price$ Excl. GST

T0001 CH-102-04 Shine Year to suit 1/4" OD tube 4.44

T0006 CH-102-05 Shine Year to suit 5/16" OD tube 4.79

T0002 CH-102-06 Shine Year to suit 3/8" OD tube 7.09

T0003 CH-102-08 Shine Year to suit 1/2" OD tube 8.26

T0004 CH-102-10 Shine Year to suit 5/8" OD tube 9.44

T0005 CH-102-12 Shine Year to suit 3/4" OD tube 10.10

Allen Key (hex key) RealcoldStock No.

Model Brand Description System Price$ Excl. GST

T2096 60710 Yellow Jacket 9 Piece Hex Key Set (fold up)

5/64”, 3/32”, 7/64”, 1/8”, 9/64”, 5/32”, 3/16”, 7/32”, 1/4”

22.08

T2098 60685 Yellow Jacket 12 Piece Hex Key Set Ball End, c/w Case

1/2”, 1/16”, 5/64”, 3/32”, 7/64”, 1/8”, 9/64”, 5/32”, 3/16”, 7/32”, 1/4”, 5/16”

79.87

CT133

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TOOLS - MISCELLANEOUS

Pinch Off ToolRealcoldStock No.

Model Description System Price$ Excl. GST

T0052 Yellow Jacket 60665 Wing Nut & Bar Style Pinch Off & Re-Rounding Tool 58.85

T0053 Shine Year CH-201 180 mm Pinch Off Pliers 16.83

Oil PumpRealcoldStock No.

Model Description System Price$ Excl. GST

T2162 Yellow Jacket 77940 Max-Flow Combination Suction/Discharge Pump. Suits all Containers.

276.42

T2164 Yellow Jacket 77930 Max-Flow Deluxe Pump 335.58

Fin CombsRealcoldStock No.

Description System Price$ Excl. GST

T0255 Wagner T-100 Kit Interchangeable Heads (4 thru 14 fpi) 28.92

T0256 Wagner Head (8 fins per inch) Orange 4.34

T0257 Wagner Head (12 fins per inch) Dark Green 4.34

T0258 Wagner Head (5 - 10 fins per inch) White 4.34

T0259 Wagner Head (11 fins per inch) Blue 4.08

T0791 CH-352 Stainless Steel Fin Comb 11.58

Oil InjectorRealcoldStock No.

Model Description System Price$ Excl. GST

T2160 Yellow Jacket 69562 Oil Injector. 118ml (4oz). 1/4” MF x 1/4” FF Quick Connector 205.02

Inspection MirrorsRealcoldStock No.

Description System Price$ Excl. GST

T0281 Spare Bulb 2.14

T0285 Inspection Mirror - Extendable 57 mm mirror 24.74

T0286 Inspection Mirror - Spare head 14.23

T1016 MA-Line 1.1/4” Round Mirror 17.34

T0053

T0285

T0255

CT134

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TOOLS / TESTING EQUIPMENT / THERMOMETERS

Miscellaneous ToolsRealcoldStock No.

Model Description System Price$ Excl. GST

T1012 MA-KVS007 Stainless Steel Pocket Knife - 2” Blade, 3” Closed 24.74

T1000 MA03200-2 Crimping Tool 15.25

T1002 MA03203-2 Deluxe Wire Stripper/Cutter 43.61

T1350 MA-DMTK K-Temp Probe 15.76

T1351 MA-FL24LED 24 LED Service Light 18.92

T1352 MA-FL72LED 72 LED Work Light 56.76

Testing EquipmentRealcoldStock No.

Model Description System Price$ Excl. GST

Temperature Test Equipment

T1314 MA-DMT123 Dual Probe Thermometer

Extra wide Temperature range from (-200°C to 1370°C) with high accuracy

363.12

T1328 MA-RT900 Hand Held Digital Thermometer

Wide Measurement range (-50°C to 200°C), never needs to be calibrated

53.60

T1332 MA-12843 Digital Anemometer 252.96

Refractometers

T1032 MA-REF401C Glycol Refractometer

Precision optical instrument designed to measure the freezing point of ethylene or propylene based cooling systems. The two Celsius non-liner scales cover -50°C to 0°C for ethylene glycol and propylene glycol. The resolution of the temperature scale is 0°C

396.78

T1033 MA-REF700 Oil Refractometer

Easy to use handheld instrument designed to accurately measure the mineral oil in polyolester (POE) lubricant during change of refrigerants

POA

MA-3200 MA-128144

MA-KVS007

MA-DMT123

MA-RT900

MA-REF700

ThermometersArthermo -40°C/+40°C dial thermometers are housed in a heavy duty nylon case with provision for bottom or back entry capillary. Can be flush or surface mounted. Can be calibrated.

RealcoldStock No.

Model Description System Price$ Excl. GST

Dial Thermometers

U0080 Realcold 60 mm dial (3000 mm capillary) 34.17U0082 Realcold 80 mm dial (3000 mm capillary) 37.33U0084 Realcold 100 mm dial (3000 mm capillary) 39.93U0091 Realcold 100 mm dial (6000 mm capillary) 52.02

Cabinet Thermometers. Thermometers have provision for recalibrationU0147 Arthermo Type 540 -40°C /+40°C 64.5 mm dial

Stainless steel case, with foot for standing & hook for hanging.

12.65

U0148 Arthermo Type 519B -40°C /+40°C 64.5 mm dial

Acrylic resin case, with hook for hanging.

6.53

CT135

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

THERMOSTATS

Domestic - RancoRealcoldStock No.

Type Application Normal °C Cold °C Warm °C System Price$ Excl. GST

Cut In Cut Out Cut Out Cut In Cut In

G0104 K50-P1125-001 Single Temp. Cabinet -9.5 - -18 - +8.5 33.20

G0110 K50-P1126-001 Freezer Cabinet -12 -18 -24 - -9.5 33.20

G0118 K50-P1127-001 Bottle Cabinet +5 - +1.5 - +12.5 33.20

G0109 VCI (K50-P1110) Single Temp. Cabinet -5 -14 -24 - +2 35.88

G0108 VF3 (K50-P1117) Freezer -18 -24 -32 - -12 48.57

G0114 VB7 (K50-P1118) Bottle Cabinet - - -3 +2 +12 43.59

G0119 VT9 (K59-L1102) Dual Temperature - - -26 +3.5 - 44.12

Commercial - RancoRealcoldStock No.

Type Range °C Differential Sensor System Price$ Excl. GST

G0125 016-6950 -35 to -7 1.7 to 12°C Coiled Capillary 130.66

G0130 016-6951 -18 to +13 1.7 to 12°C Coiled Capillary 128.52

G0135 016-6954 -5 to +25 1.7 to 12°C Coiled Capillary 130.66

G0136 016-6924 -5 to +25 1.7 to 12°C Straight Capillary Tube 131.73

G0140 016-6980 -18 to +13 1.7 to 12°C Cross Ambient Bulb 143.51

G0145 016-6981 -5 to +25 1.7 to 12°C Cross Ambient Bulb 152.08

G0148 016-6983 +10 to +40 1.7 to 12°C Cross Ambient Bulb 141.37

G0178 018-1100 0° Fixed 1/8" Ice Capillary With Bulb 195.99

G0146 Flat Mounting Bracket to suit Ranco Thermostats 7.77

• Straight and coiled capillary thermostats are used on applications where it can be guaranteed that the sensing element is always cooler than the control head. Where local sensing is required, the coiled version is used, whereas the straight version is used to sense over a longer distance eg across an evaporator coil.

• Cross Ambient Thermostats have a capillary and remote bulb. Unlike the straight or coiled capillary models, these controls sense only at the bulb. They should be used on all applications where it is possible that the control head or capillary can be at a lower temperature than the sensing bulb.

Capillary - SaginomiyaRealcoldStock No.

Type Range °C Differential Sensor System Price$ Excl. GST

G1052 XWS-C1030AGL2 Switches: 8 amps

-35 to +30°C 2 to 7°C 2 M Capillary POA

G1053 XWS-C1060AGL2 Switches: 8 amps

-5 to + 60°C 2 to 7°C 2 M Capillary POA

G1054 CNS-C114XM2 -15° to 15°C Capillary Safety Thermostat with 1m capillary. Manual Reset Fixed Differential.

POA

G1061 DTB-X178 Bottle cabinet thermostat (Skope)

Adjustable setting OFF -10°C, ON +5°C 42.02

Note: Please refer to page CD88 for Defrost Controls and to page CE100 for Electronic Controls

CT136

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

THERMOSTATS

Saginomiya Air Conditioning ThermostatsRealcoldStock No.

Type Range °C Differential Sensor System Price$ Excl. GST

G0150 VRS-C234 Q147 10 to 35°C 1.5°C fixed Room 446.25

Two stage, auto changeover, knob adjustment 2°C fixed between stages

G0151 VRS-C234Q149 10 to 35°C 1.5°C fixed Room 154.35

Two stage, auto changeover, screw driver adjustment 2°C fixed between stages

G0153 VRS-C234 Q172 10 to 35°C 1.5°C fixed Room 154.35

Two stage with auto changeover ON/OFF Switch 2°C fixed between stages

Thermostat GuardsRealcoldStock No.

Model Height Width Depth System Price$ Excl. GST

G0161 BTG-RK 162 mm 89 mm 76 mm 43.58

With Ring Base for easy installation on new or existing thermostats

G0162 TG300M 135 mm 255 mm 75 mm 68.43

With Solid Base, for new installations, or retrofitting to existing installations where the thermostat can be temporarily unscrewed from the wall, etc.

Note: Please refer to page CD88 for Defrost Controls and to page CE100 for Electronic Controls

A1 Thermostat Guards are stylish, unbreakable, and tamper-proof. A single key is provided for convenience.

Each guard comes with the guard, key, wall bracket, and four mounting screws and anchors.

Install frame on wall, hook the guard onto the frame by means of the two hooks on top, and lock.

CT137

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TUBE

Capillary Service PacksThese service packs offer a complete selection for large commercial and air conditioning units to the smallest domestic refrigeration requirements. Selection Data Information included in Pack.

RealcoldStock No.

Description System Price$ Excl. GST

G0381 SP-1 .026" ID (0.66 mm) in 3.660 metre coils 20.99

G0382 SP-2 .0315" ID (0.80 mm) in 3.660 metre coils 20.99

G0383 SP-3 .0355" ID (0.90 mm) in 3.660 metre coils 20.99

G0384 SP-4 .0435" ID (1.10 mm) in 4.270 metre coils 20.99

G0385 SP-5 .051" ID (1.30 mm) in 4.270 metre coils 20.99

G0386 SP-6 .055" ID (1.40 mm) in 3.660 metre coils 20.99

G0387 SP-7 .064" ID (1.62 mm) in 3.050 metre coils 20.99

G0388 SP-8 .070" ID (1.78 mm) in 3.660 metre coils 20.99

G0389 SP-9 .075" ID (1.90 mm) in 2.750 metre coils 20.99

G0390 SP-10 .080" ID (2.04 mm) in 3.050 metre coils 20.99

G0391 SP-11 .088" ID (2.24 mm) in 3.660 metre coils 20.99

Capillary ToolsRealcoldStock No.

Description System Price$ Excl. GST

T0165 Capillary Tube Gauge and File Set POA

T0166 Capillary Tube File Only POA

Thick Walled Hard Drawn Copper (5.8 metre lengths)Refrigeration grade, dehydrated and nitrogen purged, sealed copper tube. Manufactured in accordance with AS/NZ 1571 ASTMB 280 Refrigeration Code. Manufactured in accordance with ASTM B88 - Cleaned in accordance with ASTM B280.

RealcoldStock No.

Outside Diameter Wall Thickness SWP System Price$ Excl. GST

Inches mm Inches mm PSI kPa

H1719 3/4 19.05 0.046 1.18 665 4583 POA

H1722 7/8 22.23 0.064 1.63 795 5478 POA

H1728 1.1/8 28.58 0.072 1.83 688 4746 POA

H1735 1.3/8 34.93 0.085 2.15 660 4553 POA

H1742 1.5/8 41.28 0.102 2.6 677 4665 POA

• Soft Drawn Copper is sold per coil and Hard Drawn Copper Tube is sold in full lengths.

• Values of SWP are derived from the formula from ANSIB31 Standard Code for Pressure Piping

• The value of Maximum Stress (S) used in the calculation is 150°F (65.6°C) and is for copper in its annealed condition. For Pipe temperatures higher than 150°F (65.6°C), please contact your local Realcold branch for assistance in the selection of appropriate tube for your requirement.

• Please see Air Conditioning Catalogue for Pre-Insulated Copper Tubing. For further information on copper tube wall thickness standards; please refer to AS/NZS 1677.2 : 1998 or enquire at your local Realcold branch.

CT138

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

TUBE

Soft Drawn Copper (15.25 metre coils)RealcoldStock No.

Outside Diameter Wall Thickness SWP WT per 15.25m Length Kg

System Price$ Excl. GST

Inches mm Inches mm PSI kPa

H0002 1/8 3.17 0.030 0.762 3026 20864 0.79 POA

H0004 3/16 4.76 0.030 0.762 1867 12873 1.30 POA

H0001 1/4 6.35 0.030 0.762 1350 9308 1.82 POA

H0006 5/16 7.94 0.032 0.8128 1133 7812 2.47 POA

H0009 3/8 9.53 0.032 0.8128 930 6412 3.03 POA

H0014 1/2 12.70 0.032 0.8128 686 4730 4.12 POA

H0018 5/8 15.88 0.035 0.889 598 4123 5.69 POA

H0020 3/4 19.05 0.035 0.889 498 3413 6.91 POA

H0022 7/8 22.22 0.045 1.143 545 3758 10.34 POA

Hard Drawn Copper (full lengths)RealcoldStock No.

Outside Diameter Wall Thickness SWP WT per 5m Length Kg

System Price$ Excl. GST

Inches mm Inches mm PSI kPa

H0058 3/8 9.53 0.030 0.76 869 5992 0.94 POA

H0059 1/2 12.70 0.035 0.89 757 5220 1.47 POA

H0060 5/8 15.88 0.040 1.02 691 4764 2.12 POA

H0061 3/4 19.05 0.042 1.07 600 4137 2.69 POA

H0062 7/8 22.23 0.045 1.14 545 3758 3.38 POA

H0063 1.1/8 28.58 0.050 1.27 470 3241 4.87 POA

H0064 1.3/8 34.93 0.055 1.40 422 2910 6.57 POA

H0065 1.5/8 41.28 0.060 1.52 387 2668 8.48 POA

H0075 2.1/8 53.98 0.070 1.78 345 2379 13.02 POA

H0076 2.5/8 66.68 0.080 2.03 318 2193 18.44 POA

H0077 3.1/8 79.38 0.090 2.29 301 2075 24.77 POA

Note: NZS1677 stipulates the method of calculating the maximum operating pressure for air cooled refrigeration systems to be the highest.Price fluctuations are dictated daily by the London Metal Exchange (LME).

Soft Drawn Copper (18 metre coils)RealcoldStock No.

Outside Diameter Wall Thickness SWP WT per 18m Length Kg

System Price$ Excl. GST

Inches mm Inches mm PSI kPa

H0034 3/8 9.5 0.032 0.81 1094 7546 3.56 POA

H0035 1/2 12.5 0.032 0.81 807 5561 4.87 POA

H0036 5/8 15.8 0.040 1.02 813 5602 7.66 POA

H0037 3/4 19 0.040 1.02 671 4628 8.33 POA

H0038 7/8 22.2 0.045 1.143 642 4425 12.17 POA

Soft Drawn Copper (15 metre coils)RealcoldStock No.

Outside Diameter Wall Thickness SWP WT per 15m Length Kg

System Price$ Excl. GST

Inches mm Inches mm PSI kPa

H0031 1/4 6.35 0.032 0.8128 1711 11796 1.89 POA

H0032 3/16 4.76 0.032 0.8128 2371 16349 1.35 POA

H0033 5/16 7.94 0.032 0.8128 1338 9226 2.43 POA

• For information on soft drawn and hard drawn copper standards, please contact your local Realcold branch, Representative or visit www.realcold.co.nz

• Pre-Insulated Copper Tubing - Please see AC31.

CV139

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Flica Thermostatic Expansion Type TMV/TMVX (adsorber charged)Wide Range: R134a - MP39 - Isceon 49 - R12 = +15°C to -30°C

R22 = +15°C to -45°C

R404a - HP80 - R407B - R507 - Isceon 69L -R502 = 0°C to -50°C

RealcoldStock No.

Model Description System Price$ Excl. GST

R134a - MP39 - R12 - Isceon 49

F1602 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29

F1604 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14

F1652 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29

F1654 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14

R22 - Isceon 59

F1606 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29

F1608 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14

F1656 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29

F1658 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14

R404a - HP80 - R407B - R507 - R502 - Isceon 69L

F1610 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29

F1612 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14

F1660 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29

F1662 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14

Flica Orifices (TMV/TMVX/TMVBL/TMVXBL)Nominal capacities (kW) based on 1K subcooling/1.5 bar pressure drop.

RealcoldStock No.

Model Description System Price$ Excl. GST

R134a R22 R22 R404a R404a

-5/+40°C -5/+40°C -25/+40°C -5/+40°C -25/+40°C

F1618 Flica Orifice # 0.3 0.34 0.52 0.36 0.35 0.23 21.53

F1620 Flica Orifice # 0.5 0.65 0.98 0.69 0.66 0.43 21.53

F1622 Flica Orifice # 0.7 0.90 1.35 0.94 0.94 0.61 21.53

F1624 Flica Orifice # 1.0 1.29 1.97 1.38 1.36 0.88 21.53

F1626 Flica Orifice # 1.5 2.09 3.16 2.21 2.15 1.40 21.53

F1628 Flica Orifice # 2.0 2.69 3.99 2.79 2.72 1.77 21.53

F1630 Flica Orifice # 2.5 3.78 5.75 4.02 3.93 2.56 21.53

F1632 Flica Orifice # 3.0 6.17 9.17 6.41 6.27 4.09 21.53

F1634 Flica Orifice # 3.5 8.16 12.12 8.48 8.24 5.37 21.53

F1636 Flica Orifice # 4.5 11.04 16.89 11.81 11.52 7.50 21.53

F1638 Flica Orifice # 4.75 14.92 22.27 15.58 15.17 9.88 21.53

Note: TMV/TMVX Bodies Male Flare x Male Flare Connections TMVBL/TMVXBL Bodies Male Flare x Solder Sweat Connections

Installation: Valves may be installed in any position.Specifications: Adsorber charged diaphragm operated valve of high sensitivity. Interchangeable orifice. Wide temperature range and constant superheat.Superheating: Mean static superheat 3K.Adjustment: Initially valves should be installed with the factory setting unaltered. Should adjustment be necessary, then remove the sealing cap and adjust the spindle. Right Turn (Clockwise)- Reduces flow, thus increasing superheat. Left Turn (Anticlockwise) - Increases flow, thus decreasing superheat. One turn of the adjusting spindle alters superheat setting by approximately 8 psi.

With Adsorber charge it is impossible for charge migration or reversal to occur, thereby offering the user a reliable, trouble-free valve.

TMV

TMVXBL

Flica Thermostatic Expansion Type

Flica Orifices

CV140

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Sporlan Q-Series Thermostatic Expansion Valves3/8” x 1/2” - 90º connections, flare or sweat. All OD models are forged inlet models.

RealcoldStock No.

Model Description System Price$ Excl. GST

SP0001 SQ-ODF Q Valve Body OD Internally Equalised External Strainer 98.28

SP0002 SQE-ODF Q Valve Body OD Externally Equalised External Strainer 117.30

SP0003 Q-SAE Q Valve Body MF Internally Equalised External Strainer 77.27

SP0004 QE-SAE Q Valve Body MF Externally Equalised External Strainer 96.70

SP0071 SBQ-ODF BQ Valve Body OD Internally Equalised 98.28

SP0072 SBQE-ODF BQ Valve Body OD Externally Equalised 132.60

SP0073 BQ-SAE BQ Valve Body MF Internally Equalised 76.70

SP0074 BQE-SAE BQ Valve Body MF Externally Equalised 96.70

Sporlan OrificesRealcoldStock No.

Model Description Nominal Capacity kW System Price$ Excl. GST

R404a R22 R134a

SP0010 QC-0 Orifice No. 0 Red 0.88 1.17 0.59 11.07

SP0011 QC-1 Orifice No. 1 Yellow 1.76 2.64 0.88 11.07

SP0012 QC-2 Orifice No. 2 Green 1.76 3.52 1.76 11.07

SP0013 QC-3 Orifice No. 3 Blue 3.52 5.28 3.52 11.07

SP0014 QC-4 Orifice No. 4 Pink 5.28 8.79 5.28 11.07

SP0015 QC-5 Orifice No. 5 Black 7.03 12.3 7.03 11.07

SP0016 QC-6 Orifice No. 6 White 10.6 17.6 8.79 11.07

SP0080 AAA BQ Orifice Red 0.44-0.70 0.44-1.16 0.44-0.70 31.52

SP0081 AA BQ Orifice Yellow 0.88-1.16 1.76-2.34 0.88-1.16 31.52

SP0082 A BQ Orifice Blue 1.76-3.52 2.64-5.30 1.76-3.52 31.52

SP0083 B BQ Orifice Pink 4.40-7.03 6.16-10.60 4.40-6.16 31.52

SP0084 C BQ Orifice White 7.90-10.60 11.4-19.30 7.03-10.60 31.52

Sporlan Thermostatic ElementsRealcoldStock No.

Model Description System Price$ Excl. GST

SP0020 KT-43-VC-5' TX Element R22 Commercial -25/+10°C 57.78

SP0030 KT-43-JC-5' TX Element R134a Commercial -25/+10°C 57.78

SP0040 KT-43-SC-5' TX Element R404a Commercial -25/+10°C 57.78

SP0041 KT-43-SZ-5' TX Element R404a LT -18/-40°C 57.78

SP0042 KT-43-SZP-5' TX Element R404a LT MOP -18/-40°C 57.78

SP0043 KT-43-PC-5' TV Element R507 Commercial -25/+10°C 57.78

SP0044 KT43-VZ-5' TX Element R22 LT- Q Series -18/-40°C 57.78

SP1260 KT43-FZP-5' TX Element R134a LT MOP -18/-40°C 57.78

Sporlan AccessoriesRealcoldStock No.

Model Description System Price$ Excl. GST

SP0060 791-001 Cartridge O-Ring 5.81

SP0061 184-002 Allen Wrench 8.82

SP0062 QVT-1 Q Valve Tool 198.90

SP0063 1538-000 Inlet Strainer 11.07

SP0064 3427-000 Inlet Strainer 12.65

SQ-ODF

SQE-ODF

Q-SAE

QE-SAE

CV141

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Sporlan J8 Thermostatic Expansion ValvesSuitable for all refrigerants except Ammonia and High Pressure Carbon Dioxide. Drop-in replacement for Danfoss TX Valves. Has interchangeable orifice to control capacity. Orifices also suitable for use with Danfoss T2 and TE2 Valves

RealcoldStock No.

Model Inlet Outlet Equalised MOP Bar / °C Evap / Temp Range

System Price$ Excl. GST

SP5001 TX 134A J8S-JW BODY 3/8" Flare 1/2" Solder No - -40 to +15°C 106.00

SP5002 TX 134A J8ES-JW BODY 3/8" Flare 1/2" Solder Yes - -40 to +15°C 118.00

SP5003 TX R22 J8F-VW BODY 3/8" Flare 1/2" Solder No - -40 to +15°C 106.00

SP5004 TX R22 J8EF-VW BODY 3/8" Flare 1/2" Solder Yes - -40 to +15°C 118.00

SP5005 TX 404A J8S-SW BODY 3/8" Flare 1/2" Solder No - -40 to +10°C 106.00

SP5006 TX 404A J8ES-SW BODY 3/8" Flare 1/2" Solder Yes - -40 to +10°C 118.00

SP5015 TX 134A J8F-JW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00

SP5016 TX 134A J8EF-JW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 118.00

SP5017 TX 404A J8S-VW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00

SP5018 TX 404A J8ES-VW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 118.00

SP5019 TX R22 J8F-SW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00

SP5020 TX R22 J8EF-SW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 106.00

SP5030 TX 134A J8S-JX60 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +17°C -40 to +15°C 106.00

SP5031 TX 134A J8ES-JX60 BODY 3/8" Flare 1/2" Solder Yes 4.1 Bar +17°C -40 to +15°C 118.00

SP5032 TX R22 J8S-VX100 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +15°C -40 to +15°C 106.00

SP5033 TX R22 J8ES-VX100 BODY 3/8" Flare 1/2" Solder Yes 4.1 Bar +15°C -40 to +15°C 118.00

SP5034 TX 404A J8S-SX110 BODY 3/8" Flare 1/2" Solder No 7.6 Bar +12°C -40 to +10°C 106.00

SP5035 TX 404A J8ES-SX110 BDY 3/8" Flare 1/2" Solder Yes 7.6 Bar +12°C -40 to +10°C 118.00

SP5036 TX 404A J8S-SX35 BODY 3/8" Flare 1/2" Solder No 2.4 Bar -17°C -40 to -18°C 106.00

SP5037 TX 404A J8ES-SX35 BODY 3/8" Flare 1/2" Solder Yes 2.4 Bar -17°C -40 to -18°C 118.00

SP5038 TX 134A J8F-JX60 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +17°C -40 to +15°C 106.00

SP5039 TX 134A J8EF-JX60 BODY 3/8" Flare 1/2" Flare Yes 4.1 Bar +17°C -40 to +15°C 118.00

SP5040 TX 404A J8F-SX110 BODY 3/8" Flare 1/2" Flare No 7.6 Bar +12°C -40 to +10°C 106.00

SP5041 TX 404A J8EF-SX110 BDY 3/8" Flare 1/2" Flare Yes 7.6 Bar +12°C -40 to +10°C 118.00

SP5042 TX 404A J8F-SX35 BODY 3/8" Flare 1/2" Flare No 2.4 Bar -17°C -40 to -18°C 106.00

SP5043 TX 404A J8EF-SX35 BODY 3/8" Flare 1/2" Flare Yes 2.4 Bar -17°C -40 to +15°C 118.00

SP5044 TX R22 J8F-VX100 BODY 3/8" Flare 1/2" Flare No 4.1 Bar +15°C -40 to +15°C 106.00

SP5045 TX R22 J8EF-VX100 BODY 3/8" Flare 1/2" Flare Yes 4.1 Bar +15°C -40 to +15°C 118.00

SP5007 ORIFICE JB2-0X - - - - - 21.00

SP5008 ORIFICE JB2-00 - - - - - 21.00

SP5009 ORIFICE JB2-01 - - - - - 21.00

SP5010 ORIFICE JB2-02 - - - - - 21.00

SP5011 ORIFICE JB2-03 - - - - - 21.00

SP5012 ORIFICE JB2-04 - - - - - 21.00

SP5013 ORIFICE JB2-05 - - - - - 21.00

SP5014 ORIFICE JB2-06 - - - - - 21.00

Valve Features Advantages and Benefits

• US Manufacture and Quality

• Copper Capillary 5-Times better Conductivity than Stainless Steel

• Plasma Welded rather than Laser Welded

• New design, Long-Life Diaphragm

• Copper Connections

CV142

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Cross Reference Table - J8 / T2 / TIRefrigerant Int / Ext Inlet x Outlet

Inch: 3/8” x 1/2” (inch)Parker Item Number

J8 Code MOP °C"

T2/TE2 Part No MOP °C"

TI/TIE Part No MOP °C"

Valve Configuration Sporlan Danfoss Alco

R407C Ext flare x flare 600002 J8EF-NW no 068Z3501 no - -

R407C Ext flare x flare 600003 J8EF-NX100 +17°C 068Z3517 +15°C - -

R407C Ext flare x solder 600016 J8ES-NW no 068Z3446 no - -

R407C Ext flare x solder 600017 J8ES-NX100 +17°C 068Z3447 +15°C - -

R407C Int flare x flare 600023 J8F-NW no 068Z3496 no - -

R407C Int flare x flare 600024 J8F-NX100 +17°C 068Z3516 +15°C - -

R407C Int flare x solder 600037 J8S-NW no - no - -

R407C Int flare x solder 600038 J8S-NX100 +17°C 068Z3329 +15°C - -

R134a Ext flare x flare 600000 J8EF-JW no 068Z3348 no TIE-MW no

R134a Ext flare x flare 600001 J8EF-JX60 +17°C 068Z3349 +15°C - -

R134a Ext flare x solder 600014 J8ES-JW no 068Z3385 no TISE-MW no

R134a Int flare x solder 600015 J8ES-JX60 +17°C 068Z3389 +15°C - -

R134a Int flare x flare 600021 J8F-JW no 068Z3346 no TI-MW no

R134a Int flare x flare 600022 J8F-JX60 +17°C 068Z3347 +15°C - -

R134a Int flare x solder 600035 J8S-JW no 068Z3383 no TI-SMW no

R134a Ext flare x solder 600036 J8S-JX60 +17°C 068Z3387 +15°C - -

R404A Ext flare x flare 600004 J8EF-SW no 068Z3403 no TIE-MW no

R404A Ext flare x flare 600005 J8EF-SX110 +12°C 068Z3405 +15°C - -

R404A Ext flare x flare 600006 J8EF-SX35 -17°C "068Z3409 068Z3411"

"-10°C -20°C"

- -

R404A Ext flare x solder 600018 J8ES-SW no 068Z3415 no TIS-SW no

R404A Int flare x solder 600019 J8ES-SX110 +12°C 068Z3417 +15°C - -

R404A Int flare x solder 600020 J8ES-SX35 -17°C "068Z3430 068Z3421"

"-10°C -20°C"

- -

R404A Int flare x flare 600025 J8F-SW no 068Z3400 no TI-MW no

R404A Int flare x flare 600026 J8F-SX110 +12°C 068Z3402 +15°C - -

R404A Int flare x flare 600027 J8F-SX35 -17°C "068Z3408 068Z3410"

"-10°C -20°C"

- -

R404A Int flare x solder 600039 J8S-SW no 068Z3414 no TISE-SW no

R404A Int flare x solder 600040 J8S-SX110 +12°C 068Z3416 +15°C - -

R404A Int flare x solder 600041 J8S-SX35 -17°C "068Z3429 068Z3420"

"-10°C -20°C"

- -

R22 Int flare x solder 600061 J8S-VX100 +17°C 068Z3287 +15°C - -

R22 Int flare x solder 600059 J8S-VW no 068Z3281 no TIS-HW no

R22 Ext flare x flare 600058 J8EF-VX100 +17°C 068Z3211 +15°C - -

R22 Ext flare x solder 600057 J8ES-VX100 +17°C 068Z3290 +15°C - -

R22 Int flare x flare 600054 J8F-VX100 +17°C 068Z3208 +15°C - -

R22 Int flare x flare 600053 J8F-VW no 068Z3206 no TI-HW no

R22 Ext flare x solder 600052 J8ES-VW no 068Z3284 no TISE-HW no

R22 Ext flare x flare 600051 J8EF-VW no 068Z3209 no TIE-HW no

All - J8 orifice & filter - 0X 506032 J8C-0X - 068-2002 - T1-00X -

All - J8 orifice & filter - 00 506033 J8C-00 - 068-2003 - T1-000 -

All - J8 orifice & filter - 01 506034 J8C-01 - 068-2010 - T1-001 -

All - J8 orifice & filter - 02 506035 J8C-02 - 068-2015 - T1-002 -

All - J8 orifice & filter - 03 506036 J8C-03 - 068-2006 - T1-003 -

All - J8 orifice & filter - 04 506037 J8C-04 - 068-2007 - T1-004 -

All - J8 orifice & filter - 05 506038 J8C-05 - 068-2008 - T1-005 -

All - J8 orifice & filter - 06 506039 J8C-06 - 068-2009 - T1-006 -

This information is intended only as a guide. For further information or selection assistance, please contact your local branch. Realcold accepts no liability for the information provided and any selection is the reponsibility of the purchaser / installer.

Cross Reference Table

CV143

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Sporlan S and O-Series ValvesRealcoldStock No.

Model Refrigerant Connection Charge Capacity System Price$ Excl. GST

Tons kW

SP0734 SVE-5 R22 1/2" x 7/8" OD C 5 17.5 209.10

SP0737 SVE-8 R22 5/8" x 7/8" OD C 8 28.1 209.10

SP0741 SVE-15 R22 7/8" x 1.1/8" OD C 15 52.7 229.50

SP0756 OVE-20 R22 7/8" x 1.3/8" OD BP C 20 70.3 351.90

SP0757 OVE-30 R22 1.1/8” x 1.3/8” OD BP C 30 105 351.90

SP0758 OVE-40 R22 1.1/8" x 1.3/8" OD BP C 40 140 633.42

SP0761 OVE-40-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 40 140 630.36

SP0764 OVE-55-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 55 193 630.36

SP0767 OVE-70-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 70 245 630.36

SP0774 SSE-4-C R404a 1/2" x 7/8" OD C 4 13.7 209.10

SP0777 SSE-6-C R404a 5/8" x 7/8" OD C 6 20.5 209.10

SP0780 SSE-7-C R404a 5/8" x 7/8" OD C 7 23.9 209.10

SP0786 SSE-10-C R404a 5/8" x 7/8" OD C 10 34.1 229.50

SP0792 OSE-12 R404a 7/8" x 1.3/8" OD C 12 40.9 351.90

SP0803 SSE-4-Z R404a 1/2" x 7/8" OD Z 4 13.7 209.10

SP0806 SSE-4-ZP R404a 1/2" x 7/8" OD ZP 4 13.7 209.10

SP0809 SSE-6-Z R404a 5/8" x 7/8" OD Z 6 20.5 209.10

SP0812 SSE-6-ZP R404a 5/8" x 7/8" OD ZP 6 20.5 209.10

SP0814 SSE-7-Z R404a 5/8" x 7/8" OD Z 7 23.9 209.10

SP0817 SSE-7-ZP R404a 5/8" x 7/8" OD ZP 7 23.9 210.12

SP0820 SSE-10-Z R404a 7/8" x 1.1/8" OD Z 10 34.1 229.50

SP0823 SSE-10-ZP R404a 7/8" x 1.1/8" OD ZP 10 34.1 230.52

SP0839 OSE-12-Z R404a 7/8" x 1.3/8" OD BP Z 12 40.9 351.90

SP0840 OSE-12-ZP R404a 7/8" x 1.3/8" OD BP ZP 12 40.9 352.92

SP0841 OSE-21-Z R404a 1.1/8" x 1.3/8" OD BP Z 21 74 351.90

SP0842 OSE-21-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 21 74 352.92

SP0845 OSE-30-Z R404a 1.1/8" x 1.3/8" OD BP Z 30 105 630.36

SP0846 OSE-30-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 30 105 633.42

SP0847 OSE-35-Z R404a 1.1/8" x 1.3/8" OD BP Z 35 120 630.36

SP0849 OSE-35-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 35 120 633.42

Sporlan TX Valve Replacement HeadsRealcoldStock No.

Description System Price$ Excl. GST

SP1202 KIT KT33-VCP100 - For R22, Commercial, MOP100. Suits P, Large O and H Series Valves 98.79

SP1220 KT83-VCP100 - For R22, Commercial, MOP100. Suits C, Small O and S Series Valves 86.19

SP1221 KT83-VC - For R22, Commercial. Suits C, Small O and S Series Valves 86.19

SP1224 KT83-SC - For R404a, Commercial. Suits C, Small O and S Series Valves 86.19

SP1225 KT83-SZ - For R404a, Low Temp. Suits C, Small O and S Series Valves 86.19

SP1234 KT83-RZP - For R507, Low Temp, MOP35. Suits C, Small O and S Series Valves 86.19

C Charge: +10/-23°C Commercial Applications.CP100 Charge: Air Conditioning MOP ChargeZ Charge: -18/-40°C Low Temperature ZP Charge: -18/-40°C M.O.P. MOP valves are normally used to prevent hunting or compressor overload, or to limit flow at start-up under lightly loaded conditions. Can be used in place of a crankcase pressure regulator (in certain applications).BP Balanced Port: Balanced port valves counteract effects of pressure drop (loss of valve efficiency) working well down to 25% rated capacity. All other valves operate to 35% of rated capacity.

Type S-Series

Type O-Series

CV144

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Sporlan Solenoid Valves (less coil)RealcoldStock No.

Model Coil Description System Price$ Excl. GST

SP1402 A3F1 MKC1 Solenoid Valve 1/4" MF 85.12

SP1405 E5S120 MKC1 Solenoid Valve 1/4" OD 85.12

SP1411 B6F1 MKC1 Solenoid Valve 3/8" MF 113.22

SP1414 E6S130 MKC1 Solenoid Valve 3/8" OD 113.22

SP1415 ME6S130 MKC1 Solenoid Valve 3/8" OD Manual Lift Version 154.02

SP1427 B10F2 MKC2 Solenoid Valve 5/8" MF 162.18

SP1430 E9S240 MKC2 Solenoid Valve 1/2" OD 136.68

SP1431 ME9S240 MKC2 Solenoid Valve 1/2" OD Manual Lift Version 178.50

SP1450 E14S250 MKC2 Solenoid Valve 5/8" OD 180.54

SP1452 ME14S250 MKC2 Solenoid Valve 5/8" OD Manual Lift Version 220.32

SP1462 E19S270 MKC2 Solenoid Valve 7/8" OD 285.60

SP1464 ME19S270 MKC2 Solenoid Valve 7/8" OD Manual Lift Version 330.48

SP1472 E25S290 MKC2 Solenoid Valve 1.1/8" OD 419.22

SP1474 ME25S290 MKC2 Solenoid Valve 1.1/8" OD Manual Lift Version 463.08

SP1827 ME35S1110 MKC1/OMKC1 Solenoid Valve 1.3/8" OD Manual Lift Version 663.00

SP1829 ME42S2130 MKC2 Solenoid Valve 1.5/8” OD Manual Lift Version 887.40

SP1800 180 180 Solenoid Pilot Control 1/4” MF

For Positive Liquid Line Shutoff see Bulletin 30-20

283.56

• The E5, E6 E9 and E14 are compact solenoids with Pilot Operated construction. They may be mounted Horizontal, Side On, or in a Vertical Line.

• The E19 and E25 are Pilot Operated solenoids. They may be mounted Horizontal, Side On, or in a Vertical Line. • All E series valves feature extended connections, for installation without disassembly, using low silver content brazing alloy.

Sporlan Solenoid CoilsRealcoldStock No.

Model Description System Price$ Excl. GST

SP1900 MKC1 Solenoid Coil 240V 50HZ 58.34

SP1901 MKC1E Solenoid Coil 240V 50HZ 58.34

SP1905 MKC2 Solenoid Coil 240V 50HZ 63.60

SP1906 MKC2E Solenoid Coil 240V 50HZ 63.60

Many more models and variations are available - just ask your Realcold representative for advice.

Refer to page AC37 for 4-way valves.

E9S240, E6S130,

E5S120

E25S290, E19S270

MKC-1, MKC-2

MKC1E

CV145

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Parker Hannifin SpA Solenoid Valves (complete with coils)Suitable for all HFC and HCFC refrigerants, in liquid, suction, or hot gas. Fluid temperature range -30°C to +105°C. All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired, plus bracket.

RealcoldStock No.

Model OrificeSize (mm)

MinimumPressure (bar)

Max Diff.Pressure (MOPD) bar

Kv (m³/hr) System Price$ Excl. GST

G0250 Parker 1/4" MF DA 3 0.0 21 0.27 85.63

G0252 Parker 1/4" ODS DA 3 0.0 21 0.27 97.21

G0254 Parker 3/8" MF DA 3 0.0 21 0.27 85.63

G0255 Parker 3/8" MF PO 8 0.1 21 1.40 120.36

G0260 Parker 3/8" ODS PO 8 0.1 21 1.40 120.36

G0265 Parker 1/2" MF PO 10 0.1 21 1.75 128.52

G0270 Parker 1/2" ODS PO 10 0.1 21 1.75 128.52

G0275 Parker 5/8" MF PO 15 0.1 21 2.65 156.06

G0280 Parker 5/8" ODS PO 15 0.1 21 2.65 172.38

G0285 Parker 3/4" ODS PO 18 0.1 21 3.15 231.54

G0290 Parker 7/8" ODS PO 18 0.1 21 3.50 231.54

G0295 Parker 1.1/8" ODS PO 18 0.1 21 3.50 290.70

G0298 Parker 1.3/8" ODS PO 25.4 0.14 21 8.80 549.78

All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired.

Abbreviations: DA = Direct Acting

PO = Pilot Operated

Minimum Pressure: This is the lowest differential pressure required for the correct operation of the solenoid valve.

Maximum Pressure: This refers to the highest differential operating pressure

(MOPD): with the lowest tolerance applied on the nominal voltage-coil.

Kv = Flow Factor: Is the volume (m³/hr) which flows through the valve at a pressure drop of 1 bar across the valve at a temperature of 20°C.

Parker Hannifin SpA Solenoid Valve Spares (replacement solenoid coils)RealcoldStock No.

Model Description System Price$ Excl. GST

G0302 YE09 240 Volt 50/60 Hz 9 Watt 32.59

G0312 ZB09 240 Volt 50/60 Hz 9 Watt

(DIN 40050 = IP 65 Coil)

30.50

G0301 JB14 240 Volt 50/60 Hz 14 Watt 33.10

G0303 YB12 24 Volt DC Coil 12 Watt POA

G0307 YB19 240 Volt 50/60 Hz 11 Watt 67.78

G0310 YB09 24 Volt 50/60 Hz 9 Watt 31.52

G0313 For ZB09 Faston Connector for (G0312) (Coil DIN = IP 65) 7.96

CV146

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES - PRESSURE REGULATORS

Crankcase Pressure RegulatorsRealcoldStock No.

Model Pressure Range Size System Price$ Excl. GST

SP2003 CRO-6-0/60 0-60 psig 1/2” ODF 222.36

SP2004 CRO-6-0/60 0-60 psig 5/8” ODF 222.36

SP2009 CRO-6-30/110 30-110 psig 5/8” ODF 229.50

SP2010 CRO-6-30/110 30-110 psig 7/8” ODF 230.52

SP2012 CRO-10-0/60 0-60 psig 7/8” ODF 307.02

SP2013 CRO-10-0/60 0-60 psig 1.1/8” ODF 308.04

SP2014 CRO-10-0/60 0-60 psig 1.3/8” ODF 318.24

SP2015 CRO-10-30/110 30-110 psig 7/8” ODF 329.46

SP2016 CRO-10-30/110 30-110 psig 1-1/8” ODF 317.22

SP2017 CRO-10-30/110 30-110 psig 1-3/8” ODF 317.22

Note: See Bulletin 90-10 and 90-11 for description of operation, application, selection and specifications.

Evaporator Pressure RegulatorsRealcoldStock No.

Model Pressure Range Size System Price$ Excl. GST

SP2100 ORIT-6 0 - 50 psig 1/2” MF 276.42

SP2103 ORIT-6 0 - 50 psig 5/8” ODF 259.08

SP2104 ORIT-6 0 - 50 psig 7/8” ODF 261.12

SP2107 ORIT-6 30-100 psig 5/8” ODF 259.08

SP2109 ORIT-6 30-100 psig 7/8” ODF 261.12

SP2110 ORIT-6 30-100 psig 1.1/8” ODF 271.32

SP2114 ORIT-10 30-100 psig 7/8” ODF 370.26

SP2115 ORIT-10 30-100 psig 1.1/8” ODF 370.26

SP2116 ORIT-10 30-100 psig 1.3/8” ODF 370.26

SP2130 ORIT-10 0-50 psig 7/8” ODF 370.26

SP2132 ORIT-10 0-50 psig 1.1/8” ODF 370.26

SP2134 ORIT-10 0-50 psig 1.3/8” ODF 370.26

SP2160 SORIT-12 0-100 psig 1.1/8” OD 766.02

SP2162 SORIT-15 0-100 psig 1.3/8” OD 966.96

SP2164 SORIT-20 0-100 psig 1.5/8” OD 1,371.90

SP2204 (S) ORIT-PI-27S 0-100 psig 7/8” OD POA

SP2206 (S) ORIT-PI-29S 0-100 psig 1.1/8" OD 1,034.28

SP2214 (S) ORIT-PI-39S 0-100 psig 1.1/8" OD 1,037.34

SP2216 (S) ORIT-PI-311S 0-100 psig 1.3/8" OD 1,110.78

SP2220 (S) ORIT-PI-411S 0-100 psig 1.3/8" OD 1,110.78

SP2222 (S) ORIT-PI-413S 0-100 psig 1.5/8" OD 1,271.94

SP2224 (S) ORIT-PI-513S 0-100 psig 1.5/8" OD 1,857.42

SP2226 (S) ORIT-PI-517S 0-100 psig 2.1/8" OD 1,871.70

Note: See Bulletin 90-20 for description of operation, application, selection and specifications.

• (S) ORIT-PI’s are Evaporator Pressure Regulating Valves Piloted Internally with an Electric Shut-off option, using a MKC1 Coil - Supplied separately.

• Refer to the Realcold Technical Department for capacity ratings.

• Many more models and variations are available.

CRO-6

(S)ORIT-PI

ORIT-10

ORIT-6

CRO-10

Pressure Regulators

CV147

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Sporlan CDS ValvesThe CDS Valves are electronically operated step motor evaporator pressure regulating valves. Synchronized sig-nals to the motor provide discrete angular movement, which translates into precise linear positioning of the valve piston. Valve pistons and ports are uniquely characterised, providing superb flow resolution and performance. The CDS Valves are easily interfaced with microprocessor based controllers.

RealcoldStock No.

Model Description System Price$ Excl. GST

SP2240 CDS9 5/8” Electronic evaporator pressure regulator POA

SP2241 CDS9 7/8” Electronic evaporator pressure regulator POA

SP2242 CDS9 1 1/8” Electronic evaporator pressure regulator POA

SP2242A CDS9 1 3/8” Electronic evaporator pressure regulator POA

SP2244 CDS17 1 3/8” Electronic evaporator pressure regulator POA

SP2245 CDS17 1 5/8” Electronic evaporator pressure regulator POA

SP2246 CDS17 2 1/8” Electronic evaporator pressure regulator POA

Sporlan Hot Gas Bypass ValvesRealcoldStock No.

Model Description System Price$ Excl. GST

SP2360 ADRSE-2 1/2” ODF Hot Gas Bypass Valve 0-80 psig 250.92

Sporlan Co2 Product RangeSporlan’s growing line of products for CO2 is setting new standards for robust design and advanced technology. Contact your Realcold branch for more information.

RealcoldStock No.

Model Family MRP/MOPD Application System Price$ Excl. GST

psig bar

Electric Expansion Valves

SER 700 48 Subcritical DX, Secondary POA

SEI 620 43

Evaporator Control and Secondary Refrigerant Valves

SEI 620 43 Subcritical DX, Secondary POA

SER 700 48

SDR 620 43

CDS 700 48

Controllers, Accessories

ECM - CO2 - - Subcritical DX, Secondary POA

CO2 - Superheat - -

Kelvin CO2 - -

Temperature Sensor -40 - 210°F -40 - 100°C

Pressure Transducer 500 34

Sightglass, Filter Drier

See-All® Sightglass 650 45 Subcritical DX, Secondary POA

Catch-All® Filter Drier 650 45

Solenoid Valves E3 700/450 48/31 Subcritical DX, Secondary POA

E5S130-HP 700/450 48/31

E6S130-HP 700/450 48/31

E9S240-HP 700/450 48/31

E9S250-HP 700/450 48/31

E14S250-HP 700/450 48/31

E10S250-HP 700/450 48/31

CDS-17

CDS-9

CV148

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Mueller Ball Valves (two way)Mueller ball valves may be used on high and low pressure refrigerant lines for either gas or liquid service. Suit-able for HCFC, HFC refrigerants, and all refrigerant oils. The ball seals are carbon filled teflon. This permits higher sealing force than with virgin teflon, yet gives extended sealing life with the greater strength of the filled material. Maximum working pressure is 500 psi. Maximum temperature range -40°C to +149°C.

RealcoldStock No.

Model Description System Price$ Excl. GST

H0868 Mueller 3/8" ODS Full Port 75.12

H0869 Mueller 1/2" ODS Full Port 75.12

H0870 Mueller 5/8" ODS Full Port 78.29

H0871 Mueller 7/8" ODS Full Port 105.06

H0872 Mueller 1.1/8" ODS Full Port 155.04

H0873 Mueller 1.3/8" ODS Full Port 214.20

H0875 Mueller 1.5/8" ODS Full Port 241.74

H0876 Mueller 2.1/8" ODS Full Port 373.32

H0877 Mueller 2.5/8" ODS Reduced Port 639.54

H0878 Mueller 3.1/8" ODS Reduced Port 702.78

Mueller Liquid Receiver ValvesMaximum working pressure 500 psi. Maximum temperature rating 149°C. MP are NPT (National Pipe Thread).

RealcoldStock No.

Model Description System Price$ Excl. GST

H0951 Mueller A - 11031 1/4" MF x 1/4” MP 49.93

H0952 Mueller A - 13613 1/4” MF x 3/8” MP 63.04

H0953 Mueller A - 11030 3/8” MF x 1/4” MP 49.93

H0954 Mueller A - 13503 3/8” MF x 3/8” MP 63.04

H0955 Mueller A - 11042 1/2” MF x 3/8” MP 81.45

H0956 Mueller A - 13220 1/2” MF x 1/2” MP 96.70

H0958 Mueller A - 13183 5/8” MF x 1/2” MP 161.16

Mueller Rotalock ValvesRealcoldStock No.

Model Description System Price$ Excl. GST

H1006 1/4" Valve Flare Horizontal 3/4" R/L 66.20

H1007 3/8" Valve Sweat Horizontal 1" R/L 68.85

H1009 3/8" Valve Flare Horizontal 3/4" R/L 66.20

H1013 1/2" Valve Flare Horizontal 1" R/L 67.78

H1014 1/2" Valve OD Horizontal 1" R/L 68.85

H1017 5/8" Valve OD Horizontal 1" R/L 72.01

H1031 3/4" Valve Sweat Horizontal 1”.1/4" R/L 131.58

H1036 7/8" Valve Sweat Horizontal 1”.1/4" R/L 131.58

H1042 1.1/8" Valve Sweat Horizontal 1”.3/4" R/L 199.92

H1045 1.3/8" Valve Sweat Horizontal 1”.3/4" R/L 206.04

H1074 1.1/4" Rotalock Spud less process port 23.66

H1080 1.3/4" Rotalock Spud less process port 29.99

H1103 3/4" Teflon Fibre Seal 2.60

H1104 1" Teflon Fibre Seal 2.60

H1105 1.1/4" Teflon Fibre Seal 2.60

H1106 1.3/4" Teflon Fibre Seal 2.60

Note: Valves have top gauge connection

CV149

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Mueller Hand Shut-Off Valves (packless line valves)Mueller valves have full size openings for maximum flow with minimum restriction. The maximum working pres-sure is 500 psi with flow in direction of the arrow, and 350 psi with flow against the arrow. Working temperature range is -40°C to +90°C. All valves diaphragm type.

RealcoldStock No.

Model Description System Price$ Excl. GST

H0820 Mueller 1/4" ODS Two way straight through 124.44

H0821 Mueller 3/8" ODS Two way straight through 124.44

H0822 Mueller 1/2" ODS Two way straight through 160.14

H0823 Mueller 5/8" ODS Two way straight through 160.14

H0841 Mueller 1/4" MF Two way straight through 109.14

H0842 Mueller 3/8" MF Two way straight through 109.14

H0843 Mueller 1/2" MF Two way straight through 144.84

H0844 Mueller 5/8" MF Two way straight through 144.84

Mueller Pressure Relief ValvesValves listed are constructed and stamped with the ASME UV symbol in accordance with the requirements of the ASME and are approved by Maritime Transport - a Division of the New Zealand Ministry of Transport. The set point of the relief valve must not exceed the safe working pressure (SWP) stamped on an approved receiver.

RealcoldStock No.

Model Size Connections Pressure Settings Capacity Ratings System Price$ Excl. GST

Inlet Outlet PSI kPa Lbs Air Per Minute

G0543 Mueller A-15508-AH 1/8" MPT Atmosphere 400 3413 7.1 108.12

G0544 Mueller A-15508-AG 1/8" MPT Atmosphere 350 2578 6.3 108.12

G0545 Mueller A-15508-AE 1/8" MPT Atmosphere 300 2069 5.4 108.12

G0546 Mueller A-15509-AE 1/4" MPT Atmosphere 300 2069 5.4 108.12

G0547 Mueller A-15509-AG 1/4" MPT Atmosphere 350 2413 6.3 108.12

G0548 Mueller A-15509-AH 1/4" MPT Atmosphere 400 2578 7.1 108.12

G0559 Mueller A-15504-AE 1/2" MPT 5/8" MF 300 2069 25.4 188.70

G0565 Mueller A-15504-AG 1/2" MPT 5/8" MF 350 2413 29.5 188.70

G0567 Mueller A-15504-AH 1/2" MPT 5/8" MF 400 2578 33.5 188.70

Note: The above are National Pipe Threads 9.27

Three Way Hand Shut-Off ValvesRealcoldStock No.

Description System Price$ Excl. GST

G0580 Henry 925 Brass 1/2" FPT Dual shut off valve 222.36

G0582 Mueller Brass 1/2" FPT Dual shut off valve 354.96

• Body - Forged Steel

• Seat Discs - Steel

• Maximum Working Pressure - 400 psi (28.1 Kg/cm²)

• Maximum Temperature Rating - 115°C

Atmosphere

Straight Through

CV150

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Check Valves - Refrigerants HFC & HCFCThese valves offer minimum restriction to flow and provide a positive seal against reverse flow. They will operate in any position.

RealcoldStock No.

Model Description System Price$ Excl. GST

G0501 Mueller 1/4" Male Flare Max. working pressure 500 psi Max. Temperature +93°C

33.66

G0503 Mueller 3/8" Male Flare 38.91

G0505 Mueller 1/2" Male Flare 63.04

G0507 Mueller 5/8" Male Flare 63.04

G0490 Mueller 1/4" ODS Extended Ends 47.28

G0491 Mueller 3/8" ODS Extended Ends 49.93

G0492 Mueller 1/2" ODS Extended Ends 84.05

G0493 Mueller 5/8" ODS Extended Ends 90.37

G0509 Mueller 7/8" ODS B34235 Max. working pressure 450 psi Max. Temperature +149°C

405.96

G0510 Mueller 1.1/8" ODS B34236 “ 405.96

G0511 Mueller 1.3/8" ODS B34237 “ 659.94

G0512 Mueller 1.5/8" ODS B34238 “ 659.94

G0514 Mueller 2.1/8" ODS B34239 “ 1,125.06

Note: Reversing Valves - Please refer to page AC37.

GasketsRealcoldStock No.

Model Description System Price$ Excl. GST

G0517 Mueller 1.3/8" - 1.5/8" Gasket Suit Mueller Check Valves POA

G0518 Mueller 2.1/8" Gasket Suit Mueller Check Valves POA

Note: Mueller B342 series check valves are 4-bolt flange types for easy disassembly when brazing and can be installed vertically or horizontally. Full port construction.

CV151

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VALVES

Line Tap ValvesNeedle automatically retracts to permit unrestricted flow.

RealcoldStock No.

Description System Price$ Excl. GST

T0309 A-1 Line Tap Valve to suit 1/4”, 5/16” and 3/8” OD tube 18.36

T0310 Supco Bullet Piercing Valve for 1/4”, 5/16” and 3/8” tube 11.58T0309 T0310

T0080 T0320

T0322 T0324

T0330 T0350

T0358 T0365

T0326 T0328

Schrader Valves / Access Ports RealcoldStock No.

Description System Price$ Excl. GST

T0080 Access Port sweats into 1/4" tube or 3/8" tube 3.93

T0320 Access Port threaded 1/8" NPT 7.45

T0322 Access Port 9-way multi-fitting 1/8" through 1/2" 6.38

T0324 Access Port with 50 mm 1/4" OD copper tail 4.85

T0325 Access Valve 1/4” Flare by 5/16 OD 2.30

T0326 Access Port threaded 1/4" NPT 8.36

T0328 Access Port Tee threaded 1/8” NPT on branch, 1/4" MF on run 26.27

T0330 Access Port Tee 1/4" onto 3/8" tube 14.74

T0332 Access Port Tee 5/16 x 3/8 OD 17.55

T0350 Access Port Tee 1/4” FF Swivel Nut x 1/4" MF x 1/4” MF 27.85

T0358 Quick Seal Nut 1/4” Flare 2.30

T0360 Valve Core Remover with Core Storage Facility 35.24

T0365 Schrader Valve Core 1.02

T0370 Schrader Valve Core - Suitable for R410a 3.47

CV152

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

VIBRATION ELIMINATORS

Suitable For All HFC, HCFC RefrigerantsDesigned for installation in air conditioning and refrigeration piping to minimise transmission of vibration from the compressor or other parts of the system.

RealcoldStock No.

ODS Laying Length System Price$ Excl. GST

F0475 3/8" 210 mm 33.10

F0476 1/2" 230 mm 34.68

F0477 5/8" 247 mm 41.51

F0478 3/4" 260 mm 41.51

F0479 7/8" 292 mm 59.36

F0481 1.1/8" 332 mm 75.12

F0482 1.3/8" 380 mm 107.10

F0483 1.5/8" 435 mm 151.98

F0484 2.1/8" 510 mm 238.68

F0485 2.5/8" 609 mm 508.98

F0486 3.1/8" 686 mm 675.24

Vibration PadISO Cube is a natural rubber pad, designed to reduce vibration and noise emanating from refrigeration and air conditioning equipment. Circular design of each pad offers a suction cup effect, which eliminates the need to bolt the pad down. Standard pad is divided into 81-50 mm segments. These 50 durometer pads will withstand a load of 180 psi per each 50 mm square.

To prolong machine life, reduce maintenance cost and dampen vibration. Resists: water, aging, oil & compression set. Recommended maximum load capacity: 50 pounds per square inch.

RealcoldStock No.

Description System Price$ Excl. GST

V0265 ISO Cube Vibration Pad 8t Cubes

ISO-18 450 mm x 450 mm x 19 mm

128.52

V0290 ISO Cube Vibration Pad Single Square

50 mm x 50 mm x 19 mm

2.86

V0271 MA-Line Solid Rubber Pad 455 mm x 455 mm x 5 mm 64.11

Vibration Eliminators - Installation Hints

Install the unit as close to the compressor as possible, and at right angles to the vibration motion. Anchor the refrigerant piping at the end of the unit furthest away from the vibration source. Allow sufficient space for the unit so that it will not be subject to static compression or tension after brazing it into place. Units should be installed in a straight line; they are not intended to compensate for offset piping.

If the unit is installed in an area where condensate can accumulate on it, cover the unit with a waterproof barrier to prevent moisture from freezing under the braid and ferrules, causing the unit to rupture. Care should be taken when making the sweat connections - direct the torch flame away from the braid and clean excess flux from the unit.

For situations of severe vibration, install two units in series at right angles to one another.

Spares153

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - Medium Temperature R404aRealcoldStock No.

Description Model

C7010 AEZ4425Z

C1043 Relay MTRP0037-31

C1591 Overload MRP63AMK-3240

C2000 Capacitor 50 uf/260V

C7012 AEZ4430Z

C1045 Relay MTRP0027-31

C1504 Overload MRP56AMK-3240

C2000 Capacitor 50 uf/260V

AEZ4440Z NO COMP

C1049 Relay MTRP0030-31

C1672 Overload MST58AMN-3240

C2038 Capacitor 100 uf/260V

C7014 AEZ9440Z

C1153 Relay 3ARR3-T3AB3

C1535 Overload MSP61AMK-3242

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

AEZ4450Z NO COMP

C1027 Relay 9660-A467-158

C1587 Overload MRT28AMK-3240

C2000 Capacitor 50 uf/260V

C7016 CAE9450Z

C1154 Relay RVA4L3D

C1670 Overload MST36AMHD-3242

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C7020 CAE9460Z

C1155 Relay 3ARR3-U10AA3

C1578 Overload MST28AMK-3242

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C7021 CAE9470Z

C1154 Relay 3ARR3-UAV3

C1667 Overload MST22APK-3242

C2010 Capacitor Start 64 uf/260V

C2050 Capacitor Run 15 uf/400V

C7022 CAJ9480Z

C1210 Relay 3ARR3-U10AU3

C1581 Overload MRT24ALK-3242

C2037 Capacitor Start 88 uf/330V

C2050 Capacitor Run 15 uf/400V

RealcoldStock No.

Description Model

C7030 CAJ95102

C1145 Relay 3ARR3-U6AC3

C1675 Overload MST00ALKD-3241

C2039 Capacitor Start 100 uf/330V

C2050 Capacitor Run 15 uf/400V

C7032 CAJ95132

C1148 Relay 3ARR3T6AY3

C1651 Overload MST18AIW-3242

C2030 Capacitor Start 88 uf/260V

C2050 Capacitor Run 15 uf/400V

C7036 CAJ45172

C1125 Relay 3ARR3 T6AV3

C1680 Overload MST16AGZ-3242

C2039 Capacitor Start 100 uf/330V

C2061 Capacitor Run 17.5 uf/400V

C7038 CAJ45192

C1190 Relay 3ARR3 W10AS3

C1685 Overload CST00AHSF-3038

C2038 Capacitor Start 100 uf/260V

C2088 Capacitor Run 35 uf/400V

FH4522Z NO COMP

C1126 Relay RVA4I3R

- Overload Internal

C2042 Capacitor Start 125 uf/330V

C2085 Capacitor Run 30 uf/400V

C7040 FH4524Z

C1148 Relay 3ARR3T6AY3

- Overload Internal

C2039 Capacitor Start 100 uf/330V

C2085 Capacitor Run 30 uf/400V

C7042 FH4531Z

- Overload Internal

C2046 Capacitor Start 156 uf/330V

C2088 Capacitor Run 35 uf/400V

MRP, MRT Type MSP,MST Type

MTRP Type

3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

Spares

Spares154

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - Low Temperature R404aRealcoldStock No.

Description Model

C0532 AEZ2415Z

C1053 Relay MTRP49-31

C1504 Overload MRP56AMK-3240

C2000 Capacitor Start 50 uf/260V

C0545 CAE2417Z

C1156 Relay 3ARR3-U3AU3

C1504 Overload MRP56AMK-3240

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C0551 CAE2420Z

C1049 Relay MTRP0030-31

C1578 Overload MST28AMK-3242

C2010 Capacitor Start 64 uf/260V

C0554 CAE2424Z

C1156 Relay 3ARR3-U3AU3

C1578 Overload MST28AMK-3242

C2010 Capacitor Start 64 uf/260V

C2050 Capacitor Run 15 uf/400V

RealcoldStock No.

Description Model

C0555 CAJ2428Z

C1150 Relay 3ARR18A-101B

C1630 Overload MRT16APK-3242

C2037 Capacitor Start 88 uf/330V

C0573 CAJ2432Z

C1157 Relay 3ARR3-U10AD3

C1580 Overload MRT20ALKD-3242

C2037 Capacitor Start 88 uf/330V

C2050 Capacitor Run 15 uf/400V

C0580 CAJ2446Z

C1140 Relay 3ARR3-U10AB3

C1580 Overload MRT20ALKD-3242

C2037 Capacitor Start 88 uf/330V

C2050 Capacitor Run 15 uf/400V

C0592 CAJ2464Z

C1155 Relay 3ARR3-U10AA3

C1583 Overload MRT00AJZ-3241

C2037 Capacitor Start 88 uf/330V

C2060 Capacitor Run 20 uf/400V

C0599 FH2480Z

C1128 Relay RVA4Q3D

- Overload Internal

C2046 Capacitor Start 156/330 156uf/330V

C2070 Capacitor Run 25/400 25uf/400V

MRP, MRT Type MSP,MST Type

MTRP Type

3ARR-18 Type

9660B Type Start Capacitor

3ARR3 TypeRun Capacitor

Spares155

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - Medium/High Temperature R22RealcoldStock No.

Description Model

C0320 AEZ4425E

C1043 Relay MTRP37-31

C1591 Overload MRP63AMK-3240

C2000 Capacitor 50 uf/260V

C0325 AEZ4430E

C1080 Relay 9660-B467-138

C1504 Overload MRP56AMK-3240

C2000 Capacitor Start 50 uf/260V

C0333 AEZ4440E

C1049 Relay MTRP0030-31

C1672 Overload MST58AMN-3240

C2038 Capacitor 100 uf/260V

C0335 AEZ9440T

C1153 Relay 3ARR3U3AB3

C1535 Overload MSP61AMK-3242

C2010 Capacitor Start 64 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C0339 CAE4450E

C1049 Relay MTRP0030-31

C1578 Overload MST28AMK-3242

C2000 Capacitor 50 uf/260V

C0340 CAE9450T

C1154 Relay 3ARR3U3AV3

C1545 Overload MRT36AMHD-3242

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C0351 CAE9460T

C1154 Relay 3ARR3U3AV3

C1578 Overload MST28AMK-3242

C2000 Capacitor Start 50 uf/260V

C2005 Capacitor Run 7.5 uf/400V

C0360 CAJ9480T

C1140 Relay 3ARR3U10AB3

C1581 Overload MRT24ALKD-3242

C2039 Capacitor Start 100 uf/330V

C2050 Capacitor Run 15 uf/400V

C0375 CAJ9510T

C1140 Relay 3ARR3U10AB3

C1580 Overload MRT20ALKD-3242

C2039 Capacitor Start 100 uf/330V

C2050 Capacitor Run 15 uf/400V

RealcoldStock No.

Description Model

C0390 CAJ9513T

C1155 Relay 3ARR3U10AA3

C1585 Overload MRT00AJK-3241

C2037 Capacitor Start 88 uf/330V

C2050 Capacitor Run 15 uf/400V

C0392 CAJ4517E

C1125 Relay 3ARR3K6AV3

C1620 Overload MST00AHKE-3241

C2039 Capacitor Start 100 uf/330V

C2060 Capacitor Run 20 uf/400V

C0393 FH4522F

C1126 Relay RVA4I3R

- Overload Internal

C2042 Capacitor Start 125 uf/330V

C2085 Capacitor Run 30 uf/400V

C0394 CAH4524T

C1148 Relay 3ARRAT6AY3

- Overload Internal

C2042 Capacitor Start 125uf/330V

C2085 Capacitor Run 30uf/400V

C0395 FH4524F

C1126 Relay RVA4I3R

- Overload Internal

C2039 Capacitor Start 100 uf/330V

C2085 Capacitor Run 30 uf/400V

C0396 CAH4531E

C1125 Relay 3ARR3U4AA3

- Overload Internal

C2046 Capacitor Start 156uf/330V

C2088 Capacitor Run 35uf/400V

C0397 FH4531F

C1125 Relay 3ARR3K6AV3

- Overload Internal

C2046 Capacitor Start 156 uf/330V

C2088 Capacitor Run 35 uf/400V

MRP, MRT Type MSP,MST Type

MTRP Type

3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

Spares156

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - Options R22 (c/w start kit)RealcoldStock No.

Description Model

C0110 AJ5510F

C1190 Relay 3ARR3K10AS3

C1640 Overload MST 18AKN-3242

C2080 Capacitor Start 21 uf/330 V

C2050 Capacitor Run 15 uf/400 V

C0111 AJ5512E

C1190 Relay 3ARR3K10AS3

C1650 Overload MRT 18AJN-3242

C2080 Capacitor Start 21 uf/330 V

C2050 Capacitor Run 15 uf/400 V

C0123 AJ5513E

C1195 Relay 3ARR3K4AA3

C1651 Overload MST 18AIW-3242

C2080 Capacitor Start 21 uf/330 V

C2060 Capacitor Run 20 uf/400 V

C0124 AJ5515E

C1200 Relay 3ARR3K6AV3

C1662 Overload MRT 16AGZ-3242

C2080 Capacitor Start 21 uf/330 V

C2060 Capacitor Run 20 uf/400 V

C0126 AJ5518E

C1190 Relay 3ARR3 K10 AS3

C1663 Overload CST16AHSF-3054

C2080 Capacitor Start 21 uf/330 V

C2070 Capacitor Run 25 uf/400 V

C0127 AJ5519E

C1190 Relay 3ARR3K10AS3

C1665 Overload CST 00AHPH-3038

C2080 Capacitor Start 21 uf/330 V

C2070 Capacitor Run 25 uf/400 V

C0128 AH5524E

C1025 Relay 3ARR3U3P2

- Overload Internal

C2030 Capacitor Start 88 uf/260 V

C2088 Capacitor Run 35 uf/400 V

Electrics - Standard R22 (c/w PTC relay)RealcoldStock No.

Description Model

C0110 AJ5510F

C1011 Relay CTP9EAEQ

C1640 Overload MST 18AKN-3242

C2050 Capacitor Run 15 uf/400 V

C0111 AJ5512E

C1011 Relay CTP9EAEQ

C1650 Overload MRT 18AJN-3242

C2050 Capacitor Run 15 uf/400 V

C0123 AJ5513E

C1011 Relay CTP9EAEQ

C1651 Overload MST 18AIW-3242

C2060 Capacitor Run 20 uf/400 V

C0124 AJ5515E

C1011 Relay CTP9EAEQ

C1662 Overload MRT 16AGZ-3242

C2060 Capacitor Run 20 uf/400 V

C0126 AJ5518E

C1011 Relay CTP9EAEQ

C1663 Overload CST16AHSF3054

C2070 Capacitor Run 25 uf/400 V

C0127 AJ5519E

C1011 Relay CTP9EAEQ

C1665 Overload CST 00AHPH-3038

C2070 Capacitor Run 25 uf/400 V

C0128 AH5524E

C1011 Relay CTP9EAEQ

- Overload Internal

C2088 Capacitor Run 35 uf/400 V

MRP, MRT Type MSP,MST Type

MTRP Type

3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

Spares157

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - Medium/High Temperature R134aRealcoldStock No.

Description Model

C0504 AZ3414Y

C1010 Relay CTP MSDAI

C1527 Overload MRP390HZ-3007

C0505 AZ4419Y

C1012 Relay MTRP-0140-31

C1527 Overload MRP390HZ-3240

C2030 Capacitor Start 80 uf/260V

C0525 AEZ4430Y

C1080 Relay 9660-B467-138

C1543 Overload MRP61AMK-3240

C2000 Capacitor Start 50 uf/260V

C0535 CAE4440Y

C1047 Relay MTRP0012-31

C1523 Overload MRP380AMK-3240

C2022 Capacitor Start 72 uf/260V

C0536 CAE4448Y

C1047 Relay MTRP0012-31

C1560 Overload MRP36AMHD-3240

C2010 Capacitor Start 64 uf/260V

C0537 CAE4456Y

C1049 Relay MTRP0030-31

C1607 Overload T0691-A0

C2010 Capacitor Start 64 uf/260V

C0538 CAJ4452Y

C1205 Relay 3ARR18A-44B

C1582 Overload MRT26ALKD-3242

C2010 Capacitor Start 64 uf/260V

C0550 CAJ4461Y

C1205 Relay 3ARR18A-44B

C1581 Overload MRT24ALKD-3242

C2010 Capacitor Start 64 uf/260V

C0575 CAJ4492Y

C1160 Relay 3ARRA18A-98B

C1616 Overload MRT24AJN-3242

C2010 Capacitor Start 64 uf/260V

C0590 CAJ4511Y

C1155 Relay 3ARR3U10AA3

C1585 Overload MRT00AJK-3241

C2039 Capacitor Start 100 uf/330V

C2050 Capacitor Run 15 uf/400V

C0593 FH4518Y

C1190 Relay 3ARR3W10AS3

- Overload Internal

C2030 Capacitor Start 88 uf/260V

C2070 Capacitor Run 25 uf/400V

C0595 FH4525Y

C1125 Relay 3ARR3K6AV3

- Overload Internal

C2039 Capacitor Start 100 uf/330V

C2085 Capacitor Run 30 uf/400V

MRP, MRT Type MSP, MST Type

MTRP Type

3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

Low Temperature CompressorsRealcoldStock No.

Description Model

C0501 AZ1335Y

C1010 Relay CTP-MSDA1

C1601 Overload MRP 419HZ-3240

C0502 AZ1339Y

C1010 Relay CTP-MSDA1

C1601 Overload MRP 419HZ-3240

C0503 AEZ1358Y

C1010 Relay CTP-MSDA1

C1527 Overload MRP 390HZ-3240

C0522 AEZ2380Y

C1045 Relay MTRP0027-31

C1505 Overload MRP59AMHD-3240

C2000 Capacitor 50 uf/260 V

C0530 CAE2410Y

C1045 Relay MTRP0027-31

C1550 Overload MRT39AMHD-3240

C2000 Capacitor 50 uf/260 V

C0534 CAE2412Y

C1045 Relay MTRP0027-31

C1550 Overload MRT39AMHD-3240

C2000 Capacitor 50 uf/260 V

Spares158

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE GREENLINE COMPRESSORS

Electrics - High Temperature R12RealcoldStock No.

Description Model

C0015 AE6ZA7

C1030 Relay 9660-B467-111

C1523 Overload MRP380AMK-3240

C0018 AE5ZA9

C1040 Relay 9660-B467-125

C1523 Overload MRP380AMK-3240

C0028 CAE41ZF11

C1090 Relay 9660-B467-145

C1560 Overload MRP36AMHD-3240

C2000 Capacitor 50 uf/260 V

C0036 CAE4440A

C1100 Relay 9660-B467-149

C1556 Overload MRP36AMK-3240

C2030 Capacitor 88 uf/260 V

C0040 CAJ4452A

C1205 Relay 3ARR18A-44B

C1582 Overload MRT26ALKD-3021

C2010 Capacitor 64 uf/260 V

C0055 CAJ4461A

C1205 Relay 3ARR18A-44B

C1581 Overload MRT24ALKD-3242

C2010 Capacitor 64 uf/260 V

RealcoldStock No.

Description Model

C0074 CAJ4492A

C1160 Relay 3ARR18A-98B

C1616 Overload MRT24AJN-3242

C2010 Capacitor 64 uf/260 V

C0100 CAJ4511A

C1155 Relay 3ARR3 U10 AA3

C1610 Overload MST16 AHKE 3242

C2037 Capacitor Start 88 uf/330 V

C2050 Capacitor Run 15 uf/400 V

C0017 AZ0387A

C1010 Relay CTP MSDAI

C1508 Overload MSP390HZ-3240

C0020 AZ0411A

C1010 Relay CTP MSDAI

C1508 Overload MSP390HZ-3240

MRP, MRT Type MSP, MST Type

MTRP Type

3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

Spares159

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

L’UNITE HERMETIQUE COMPRESSORS

Electrics - Low Temperature R12RealcoldStock No.

Description Model

C0010 AEZ1336A

C1010 Relay CTP MSDA-I

C1510 Overload MRP 379HK-3240

C0012 AEZ1343A

C1010 Relay CTP MSDA-I

C1523 Overload MRP380AMK-3240

C0019 AEZ1360A

C1010 Relay CTP MSDA-I

C1523 Overload MRP380AMK-3240

C0022 CAE4ZF11

C1080 Relay 9660-B467-138

C1591 Overload MRP63AMK-3240

C2000 Capacitor 50 uf/260 V

C0024 AEZ1380A

C1070 Relay 9660-B467-131

C1540 Overload MRP304AMN-3240

C0026 CAE2410A

C1080 Relay 9660-B467-138

C1550 Overload MRT39AMHD-3240

C2000 Capacitor 50 uf/260 V

C0037 CAE2412A

C1100 Relay 9660-B467-149

C1550 Overload MRT39AMHD-3240

C2030 Capacitor 88 uf/260 V

MRP, MRT Type MSP,MST Type

MTRP Type 3ARR-18 Type

9660B Type

Start Capacitor

3ARR3 Type

Run Capacitor

RealcoldStock No.

Description Model

C0058 CAJ2T12

C1150 Relay 3ARR18A-101B

C1605 Overload T0155-C2

C2010 Capacitor 64 uf/260 V

C0060 CAJ2428L

C1150 Relay 3ARR18A-101B

C1630 Overload MRT16APK-3242

C2037 Capacitor 88 uf/330 V

C0077 CAJ2446L

C1140 Relay 3ARR3 U10AB3

C1580 Overload MRT20ALKD-3242

C2037 Capacitor Start 88 uf/330 V

C2050 Capacitor Run 15 uf/400 V

C0105 CAJ2464L

C1155 Relay 3ARR3 U10AA3

C1583 Overload MRT00AJZ-3241

C2037 Capacitor Start 88 uf/330 V

C2060 Capacitor Run 20 uf/400 V

C0011 AZ1335A

C1010 Relay CTP MSDAI

C1601 Overload MSP419HZ-3240

C0014 AZ1340A

C1010 Relay CTP MSDAI

C1601 Overload MSP419HZ-3240

C0021 AEZ2380C

C1080 Relay 9660-B467-138

C1506 Overload MRP61AMGE-3240

C2010 Capacitor 64 uf/260 V

Spares160

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSOR SPARES - FRASCOLD MK II

FRASCOLD MK II - SEMI-HERMETICRealcoldStock No.

To Suit System Price$ Excl. GST

Gasket Set

R0002 B159, B210 POA

R0011 A075, A157 POA

R0032 D213, D313, D318 POA

R0041 F416 POA

R0051 F424 POA

R0052 F524 POA

R0061 F519 POA

R0066 F728 POA

R0072 Q-Series POA

R0074 S733 POA

R0078 S739, S1039 POA

R0088 S1051 POA

R0091 S1551 POA

R0095 V1559, V2059 POA

R0105 V1571, V2071 MK2 POA

R0106 V2571 MK2 POA

R0108 V2084 POA

R0112 V3084 POA

R0115 Z25106, Z35106 POA

R0116 Z30126, Z40126 POA

R0117 Z40154, Z50154 POA

R0118 W50187, W60187 POA

R0119 W60206, W70206 POA

Piston

R0121 A075, A157 POA

R0123 A16, B159, B210 POA

R0127* F416, S733 POA

R0129 D213, D313, D318, F519, S739, S1039

POA

R0131* D213, D313, D318, F519, S739, S1039

POA

R0137* F424, F524 POA

R0144* F728, S1051, S1551 POA

R0215 F416, T28, T732 POA

R0195 F424, F524 POA

R0251 V1559, V2059 MK2 POA

R0252 V1571, V2071, Z25106, Z35106 POA

R0253 V2084, V2584, Z30126, Z40126

POA

R0254 Z40154, Z50154, W60206, W70206

POA

R0255 W50187, W60187 POA

RealcoldStock No.

To Suit System Price$ Excl. GST

Conrod

R0122 A075, A16 POA

R0124 A157 POA

R0125 B159 POA

R0128 D213, D313 POA

R0132 D318 POA

R0196 F416, F424, F519, F524 POA

R0197 F728 POA

R0262 V1559, V1571, V2059, V2071, V2084, V2584, Z25106, Z30126, Z35106, Z40126, Z40154, Z50154

POA

Piston & Conrod Assembly

R0151 A075 POA

R0152 A157 POA

R0153 A16 POA

R0154 B159 POA

R0155 B210 POA

R0156 D213, D313 POA

R0157 D318 POA

R0158 F416 POA

R0159 F519 POA

R0161 F424, F524 POA

R0162 F728 POA

R0163 S733 POA

R0164 S739, S1039 POA

R0165 S1051, S1551 POA

R0166 V1559, V2059 POA

R0167 V1571, V2071 POA

R0168 Z30126, Z40126 POA

R0169 Z40154, Z50154 POA

R0171 W50187, W60187 POA

R0172 W60206, W70206 POA

R0173 Q728 POA

R0174 Q728.1Y POA

* 1997 or later.

Spares161

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSOR SPARES - FRASCOLD MK II

FRASCOLD MK II - SEMI-HERMETICRealcoldStock No.

To Suit System Price$ Excl. GST

Bearing SetR0271 A075, A16, A157, B159, B210 POAR0281 D213, D313, D318 POAR0291 F416, F424, F519, F524, POAR0302 S Series MK3 POAR0312 V1559, V2059, V1571, V2071, V2084,

V2584, Z25106, Z35106, Z30126, Z40126, Z40154, Z50154

POA

R0314 W50187, W60187, W60206, W70206 POA

Valve Plate AssemblyR0421 A075, A157 POAR0442 B210 POAR0443 D213 POAR0444* D213 POAR0448* D313, D318, Q728 POAR0469* F519, S733, S1039 POAR0479* F424 POAR0481* F524 POAR0484* F728 POAR0499* S739 POAR0505 S1051 POAR0507* S1551 POAR0509 S1551 POAR0514 V1559 POAR0515 V2059 POAR0538 V1571, Z25106 POAR0535 Z35106, V2571 POAR0539 V2084, Z30126 POAR0536 V2584, Z40126 POAR0540 Z40154 POAR0541 Z50154, W70206 POAR0542 W60206 POAR0543 W50187 POAR0544 W60187 POAR0422 A16 POAR0423 B159 POAR0468 F416 POAR0511 S1551 POA

Discharge Valve C/W GasketR0561 1/2 MF A075, A16, A157, B159 POAR0571 5/8 MF B210 POAR0572 5/8 OD D213, D313, D318 POAR0601 3/4 OD F416, F424, F519, F524 POAR0603 3/4 OD F524, F528, Q528 POAR0610 1.1/8 OD (Flange Type)

V1559,V1571, V2059, V2071, V2084

POA

R0653 1.3/8 OD (Flange Type) Z25106, Z30126, Z35106

POA

R0670 1.5/8 OD (Flange Type) Z40126, Z40154, Z50154

POA

R0672 2.1/8 OD (Flange Type) W60206, W70206

POA

Suction Valve C/W Gasket

R0563 5/8 MF A075, A16, A157, B159 POAR0602 3/4 OD B210 POAR0603 3/4 OD D213 POAR0581 7/8 OD D213 POAR0592 1.1/8 OD D313, D318 POAR0593 1.1/8 OD F416, F424, F519, F524 POAR0670 1.5/8 OD (Flange Type)

V1559, V1571, V2059, V2071, V2084

POA

R0675 2.1/8 OD (Flange Type) V2584, Z25106, Z30126, Z35106

POA

R0676 2.5/8 OD W50168, W50187, W60187, W60206, W70206

POA

R0677 2.5/8 OD (Flange Type) Z40126, Z40154, Z50154, W5018, W60187, W60206, W70206

POA

Thrust Bearing Assembly

R0309 Thrust Washer Assy. W Series POA

Semi-Hermetic Frascold MKII - MiscellaneousR0727 Oil Pump Assembly to suit V & Z series POA

R0726 Oil Pump Assembly to suit W series POA

R0850 Kriwan 69P Module Solid State Oil Protection Control (V, Z, W Modules)

POA

R0730 Compressor Sight Glass c/w 'O' Ring POA

R0731 Oil Balance Valve (to suit any compressor with sight glass)

POA

R0735 Oil Filter Screen Assy V, Z, W Series POA

R0720 Suction Screen V Series POA

R0737 Oil Balance Line Attachments POA

R0965 Sensor Electronic Injection POA

R0966 Unloader Solenoid Valve W/ Coil POA

R0967 Coil 230V 50/60HZ 10W POA

R0968 Plug IP67 POA

R0969 Gasket Sol. Valve POA

Semi-Hermetic Screw Compressor - Miscellaneous

R1002 Oil Flow Switch POA

R1003 Oil Filter Cartridge POA

R1005 Kriwan INT 69V Lubrication POA

R1006 Oil Level Control POA

R1007 Oil Heater 300W POA

R1008 Thermostat / Sensor POA

R1009 Thermostat / Pocket POA

R1010 Bearing Set C-TSH8 120 360Y POA

R1011 Gasket Set C-TSH8 120 360Y POA

R1012 Module INT 69 FRY POA

R1013 Frascold Oil Heater - Screw POA

R1014 Oil Lever Control CTSH 100-300 POA

R1015 Suction Filter POA

R1016 Oil Flow Switch Kit POA

R1017 Oil Strainer - Screw POA

R1018 Suction Valve Kit POA

* 1997 or later.

Spares162

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSOR SPARES - FRASCOLD MK II

Electrics To Suit Three Phase ModelsRealcoldStock No.

To Suit System Price$ Excl. GST

R0820 Thermistor Module All Models, 3 phaseI NT69

POA

R0822 Thermistor Module with delay INT 69TM-V, Z, W

POA

Part Winding Start 380/415Volt 50HzRealcoldStock No.

To Suit System Price$ Excl. GST

R0879 15HP Assembly

Suits S1551

POA

R0880 Stator/Rotor Assembly 20 HP

Suits V2059, V2071, V2084

POA

R0882 Stator/Rotor Assembly 25 HP

Suits V2584, Z25106

POA

R0884 Stator/Rotor Assembly 30 HP

Suits Z30126

POA

R0886 Stator/Rotor Assembly 35 HP

Suits Z35106

POA

R0888 Stator/Rotor Assembly 40 HP

Suits Z40126, Z40154

POA

R0890 Stator/Rotor Assembly 50 HP

Suits Z50154

POA

R0892 Stator/Rotor Assembly 50 HP

Suits W50187

POA

R0894 Stator/Rotor Assembly 60 HP

Suits W60187, W60206

POA

R0896 Stator/Rotor Assembly 70 HP

Suits W70206

POA

Electrics To Suit Single Phase ModelsRealcoldStock No.

To Suit System Price$ Excl. GST

A075, KEY 007

R0800 Relay RVA4M3C POA

R0830 Overload EL1 POA

R0790 Capacitor Start 160-200uf 380V POA

R0780 Capacitor Run 16uf/450V POA

A16, NEO 010

R0800 Relay RVA4M3C POA

R0830 Overload EL1 POA

R0790 Capacitor Start 160-200uf 380V POA

R0810 Capacitor Run 20uf/450V POA

A157, FRU 15

R0750 Relay RVA4N3C POA

R0842 Overload EL3 (A157) POA

R0760 Capacitor Start 200-250uf 380V POA

R0770 Capacitor Run 25uf/450V POA

B159, TER 15

R0750 Relay RVA4N3C POA

R0842 Overload EL3 (B159) POA

R0760 Capacitor Start 200-250uf 380V POA

R0770 Capacitor Run 25uf/450V POA

Spares163

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

RITCHIE - YELLOW JACKET VACUUM PUMP SPARES

Ritchie - Yellow Jacket Vacuum Pump SparesRealcoldStock No.

Model Description System Price$ Excl. GST

T2451 93441 Replacement cartridge for 95 L pump POA

T2452 93461 Replacement cartridge for 142 L pump POA

T2453 93012 Crystal for Vacuum Gauge Suits Vacuum Pumps POA

T2454 93011 Vacuum Gauge POA

T2456 93098 Oil Drain Valve 70-120-18 L POA

T2457 93403 Oil Sight Glass (fits pumps manufactured up until 1997) POA

T2467 93365 Oil Sight Glass (fits 95 and 142 l/m pumps (manufactured from 1998 on) POA

T2458 93404 Oil Case Gasket (fits 95 and 142 l/m pumps (manufactured from 1998 on) POA

T2459 93386 Exhaust Filter POA

T2460 93387 Filter Element POA

T2461 93114 Motor Switch POA

T2462 93047 Drive Coupling POA

T2463 93344 Gasket - Oil Cover Case 35L POA

T2464 93031 Shaft Seal POA

T2465 93045 Motor Capacitor POA

T2466 93078 Oil Case Screw POA

T2468 93048 Oil Cover Gasket 85-96 Suits Vacuum Pumps POA

T2469 93369 Oil Cover Gasket 98-05 Suits Vacuum Pumps POA

T2470 93146 Electric Motor 115/230V 50/60 Hz POA

T2471 93507 Oil Cover Gasket 05 Suits Vacuum Pumps POA

T2472 93368 Gas Ballast 93368 Suits Vacuum Pumps POA

T2473 93509 Gas Ballast 93509 Suits Vacuum Pumps POA

T2474 93032 O-Ring Gas Ballast 93032 Suits Vacuum Pumps POA

T2475 93398 O-Ring Gas Ballast 93398 Suits Vacuum Pumps POA

T2476 93117 Rocker Switch 93117 POA

Note: Except for the cartridges, all other spares are inter-changeable.

Spares164

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

RITCHIE - YELLOW JACKET SPARES

Ritchie - Yellow Jacket SparesRealcoldStock No.

Model Description To Suit System Price$ Excl. GST

Manifold PartsT2609 19015 Gasket T2206 CH-80 3.83T2610 41103 3/8" Piston 48584 18.55T2611 41043 Titan Piston Assembly 49833, 49869 16.50T2612 41133 1/4" Piston 41382, 42010 13.40T2614 41134 Feed Screw 41382, 48584 17.55T2615 41056 Titan/Bantam Feed Screw 49833, 49869, 45936 13.40T2616 41107 Retaining Nut 48584 20.60T2617 41094 Brute II Red Handle 46140, 46160 13.40T2618 41104 Red Handle 48584 13.40T2619 41044 Titan Red Handle 49833, 49869 13.40T2620 41102 Blue Handle 48584 13.40T2621 41092 Brute II Blue Handle 46140, 46160 13.40T2622 41101 Yellow Handle 48584 13.40T2623 41042 Titan Blue Handle 49833, 49869 13.40T2624 41142 Handle Screws (Set of two) 41382, 48584 7.20T2625 41091 Brute II Yellow Handle 46140, 46160 13.40T2626 41041 Titan Yellow Handle 49833, 49869 13.40T2627 41090 Handle Screws Brute II 46140, 46160 7.20T2628 40279 Hanging Hook 41382, 48584 11.85T2629 41048 Titan Handle Screw 49833, 49869 7.20T2630 41108 Sight Glass 48584 48.95T2631 41096 Retaining Nut Brute II 46140, 46160 20.60T2633 41049 Retaining Nut Titan 49833, 49869 11.35T2632 41109 Sight Glass "O"-Ring 48584 8.75T2634 41135 Retaining Nut 41382 11.35T2636 41141 Handle Screw & Washer 41382 10.25T2641 41051 Yellow Handle 45836, 45936 13.40T2642 41052 Blue Handle 45836, 45936 13.40T2643 41053 Piston / "O"-Ring 45836, 45936 16.50T2644 41054 Red Handle 45836, 45936 13.40T2645 41055 O-Rings 45836, 45936 1.85T2646 41056 Feed Screw 45836, 45936 13.95T2647 41057 Retaining Nut 45836, 45936 11.35T2648 41058 Handle Screw/Washer 45836, 45936 7.20T2650 41061 Sight Glass Assembly 45836, 45936 48.95T2651 41131 Manifold O-Rings Series 41 42010 1.85T2653 41134 Series 41 Valve Feed Screw 42010 13.95T2657 41143 Series 41 Valve Assembly 42010 33.00T2658 41047 O-Ring Sight Glass Brute II and Titan 9.80

Flaring & Swaging Tool SparesT2558 60443 Yoke for 60440 154.00T2560 60213 Yoke for 60210 61.30T2562 60271 Yoke for 60270 143.00T2564 60212 Flaring Bar 3/16” - 5/8” for 60210, 60440 79.35T2566 60232 Flaring Bar 1/2” - 3/4” for 60210, 60440 140.00T2568 60449 Flaring Cone only 42.75

Swage AdaptorsT2580 60444 Swage Adapter 3/16” - 3/8” 51.00T2581 60439 Swage Adapter 1/4” 50.00T2582 60445 Swage Adapter 5/16” 50.00T2583 60446 Swage Adapter 1/2” 50.00T2584 60447 Swage Adapter 5/8” 50.00T2585 60448 Swage Adapter 3/4” 51.00

Spares165

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

REALCOLD EVAPORATOR SPARES

Realcold Evaporator SparesRealcoldStock No.

Description To Suit System Price$ Excl. GST

W7500 Fan Motor Rondo 140-700, RDD 300-900, RCT 240-540 POA

W7501 Fan Blade Rondo 140-700, RDD 300-900, RCT 240-540 POA

W7502 Fan Guard Rondo 140-700, RDD 300-900, RCT 240-540 POA

W7503 Bracket Rondo 140-700, RDD 300-900, RCT 240-540 POA

W7504 Fan Motor Rondo 900-1300 and RCM 1300-2500 and NST range POA

W7505 Fan Blade Rondo 900-1300 and RCM 1300-2500 POA

W7506 Fan Guard Rondo 900-1300 and RCM 1300-2500 POA

W7507 Bracket Rondo 900-1300 and RCM 1300-2500 POA

W7511 Fan Blade NST range POA

W7512 Fan Guard NST range POA

W7513 Fan Motor RDD 100-200 and RCT 160 POA

W7514 Fan Blade RDD 100-200 and RCT 160 POA

W7515 Fan Guard RDD 100-200 and RCT 160 POA

W7516 Bracket Ring Mount RDD 100-200 and RCT 160 POA

W7517 Electric Lead w/plug 1500 mm POA

W7518 Electric Lead w/plug 3000 mm POA

W7521 Terminal Box POA

W7535 Fan Assy - RST POA

Fan Guards

D0182 Fan Guard 200 mm Fan POA

D0183 L’Unite 200 mm AEZ / AE cond units (large - 2 piece) POA

D0184 Fan Guard 200 mm Fan POA

D0185 L’Unite 250 mm CAE / CAJ cond units (small - 1 piece) POA

D0186 L'Unite 300 mm CAJ cond units (large - 1 piece) POA

D0187 L'Unite 356 mm FH / TFH cond units (1 piece) POA

M0160 To suit 879-300 (M0159) Fan Motor POA

Spares166

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

REALCOLD EVAPORATOR DEFROST ELEMENT

Realcold Evaporator Defrost ElementRealcoldStock No.

Description Length Quantity Per Unit Watts (230V) System Price$ Excl. GST

Tray - U Core Tray - U Core Tray - U Core

W7200 F04806 U-Shaped Element

to suit NL112, NL115, NL118

560 1 1400 POA

W7202 F04807 U-Shaped Element

to suit NL120, NL123

765 1 1800 POA

W7204 F04808 U-Shaped Element

to suit NL228, NL234, NL239

1065 1 2400 POA

W7206 F04973 U-Shaped Element

to suit SL261

1320 1 2000 POA

W7208 F04809 U-Shaped Element

to suit NL347, NL364

1565 1 3600 POA

W7210 F04810 U-Shaped Element

to suit NL455, NL468, SL374, SL392, SL3110

2065 1 4800 POA

W7212 F04974 U-Shaped Element

to suit SL4120, SL4145

2560 1 3200 POA

W7220 F03170 Tray Element

to suit VL2280

2170 2 1800 POA

W7222 F03205 Tray Element

to suit RL3160, RL3185, RL3200, VL2300

2560 (RL3160, RL3200),

3170 (RL3185),

2670 (VL2300)

2 3200, 1800 (RL3200)

POA

W7224 F03240 Tray Element

to suit SL5180, RL4220, RL4250, VL3350, VL3400

3170 1 (SL5180),

2

1800 (SL5180, VL3400),

3200

POA

W7226 F04178 Tray Element

to suit VL4450

3475 2 3200 POA

W7228 F02925 Tray Element

to suit VL4500

3820 2 3600 POA

W7240 F03617 Core Element

to suit SL261, SM271P

1260 3

2 (SM271P)

750 POA

W7242 F02785 Core Element

to suit SL374, SL392, SL3110, VL2280, SM386P, SM3105P, SM3125P

2000 3 (SL374, SL392),

4 (SL3110),

6 (VL2280)

2 (SM386P, SM3105P, SM3125P)

1200 POA

W7244 F02820 Core Element

to suit SL4120, SL4145, RL3160, RL3200, VL2300, SM4140P, SM4165P

2500 3 (SL4120, SL4145),

4 (RL3160),

6 (RL3200, VL2300)

2 (SM4140P, SM4165P)

1500 POA

W7246 F02855 Core Element

to suit SL5180, RL4220, RL4250, VL3350, VL3400, SM5210P

3000 4 (SL5180),

6 2 (SM5210P)

1800 POA

W7248 F03668 Core Element

to suit VL4450

3350 6 2000 POA

W7250 F02890 Core Element

to suit VL4500

3650 6 2200 POA

CX167

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Com

pone

nts

COMPRESSOR AND CONDENSING UNIT WARRANTY

CompressorsRealcold Ltd standard warranty covers the start up of all com-pressors. For extended warranty the following charges apply:

Extended Warranty Charges

Sealed Compressors - All brands - 4% on sale price

Semi-Sealed Compressors - All brands - 4% on sale price

Compressors will be repaired or replaced under warranty if returned within 12 months of purchase date, provided that com-pressor, complete with original electrics, is returned to point of purchase, freight paid, accompanied by a compressor failure report.

Realcold Ltd shall not be held responsible for failure or damage resulting from misuse or incorrect installation.

Condensing UnitsSealed & Semi-Sealed

Warranty is included in the price listed for condensing units and includes replacement of all components for a 12 month period from date of purchase, provided component is returned along with Goods Returned Form to point of purchase, freight paid.

Note:

Replacement components will be debited against the account of the purchaser, with credit to follow upon receipt and inspection of faulty component.

Realcold Ltd shall in no event be liable for any indirect or conse-quential loss or damage whatsoever.

Refer to the back of this catalogue for our General Terms of Trade. Goods Returned Forms are available from your representative, or any of our branches.

COMPRESSOR AND CONDENSING UNIT WARRANTY

Industrial

Components

Indu

stria

l

IndustrialHansen Introduction IN170

Stop And Regulating Valves IN171

Pressure Regulators IN172

Control Valve Pilots IN173

Strainers IN175

Flanges And Adaptor Rings IN176

Complete Valve Combination IN177

Solenoid Valves IN178

Pressure Relief, Gauge & Transducer Valves IN179

Float Controls, Level Probes & Switches, Sight Glasses IN180

Auto Purgers IN181

Check Valves IN183

Multi Port Valves IN184

Motorised Valves IN185

2-Step Solenoid, Suction Stop & Oil Change Valves IN186

Ammonia & Other Gas Sensors IN187

Refrigerant Pumps IN188

Valves - Solenoid Coils IN191

Valves - Spares IN192

IN170

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

HANSEN INTRODUCTION

Hansen is one of the largest manufacturers of Industrial Refrigeration Products in the world.

Manufactured in the USA and exported world wide, the Hansen brand is synonymous with quality, performance and reliability.

As well as producing the normal range of valves, controls and float switches, Hansen also market a range of Auto-Purgers, Motorized Valves, Ammonia Detectors, Refrigerant Pumps (for Ammonia Carbon Dioxide and other industrial gases) and specialist controllers designed specifically for the Industrial Refrigeration Market.

Bespoke Control Valves: We can assemble almost any combination of valve from stocked, modular valve bodies and pilots to satisfy the majority of applications that you might require.

Additionally, we are able to fit the full range of Danfoss Pilots and controllers onto the Hansen modular bodies, to meet your requirements. Most of these items are available ex-stock from our Auckland Central Warehouse and can be made up to order.

Refrigerant Float Switch: The HLLE refrigerant liquid level float switches are used to electrically indicate or control a liquid level, by opening or closing a SPDT switch. Their simple, reliable design provides a life time of per-formance for almost any application

Applications: These refrigerant level float switches are typically installed on a vessel’s liquid level column. They can control liquid level by activating a liquid fill solenoid valve. Often, they are used to provide high level cut-out or alarm. They are often used to turn off a recirculating liquid pump if a low level occurs. Other applications include control of liquid level via a liquid exit solenoid valve, level indication via a pilot light, and transfer drum operation.

Techni-Level Transducer Probes: The Hansen Techni-Level has fast become the industry standard for liquid refrigerant level control and monitoring. These reliable, well engineered electronic level transducer probes, when properly used, operate trouble free and are not affected by reasonable changes in refrigerant temperature or pressure. They provide a computer compatible 4-20 mA (milliamp) output signal proportional to liquid level.

Probes consist of a compact, electronic transmitter in a watertight housing assembled on top of a rugged, capacitance type level sensor. Normally, the probe must be inside a level column.

Typical applications include: vertical and horizontal vessels, pump accumulators, pilot receivers, and refrigerant loss monitoring. These probes are operating control devices and should never be used as safety devices.

Hansen Auto Purgers: A variety of Auto Purgers are available from the mini Non-Electric Auto Purger (NEAP) to the Auto Purger Plus. These units reduce condensing pressure and lower power costs by removing non-condensable gas and water from Ammonia and Halocarbon refrigeration systems.

For more information on industrial products please call +64 (0)9 526 5955.

IN171

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

STOP AND REGULATING VALVES

Hansen Stop Valves - AmmoniaRealcoldStock No.

Description System Price$ Excl. GST

Straight Through (Globe) Stop Valves - Socket Weld

12993 Hansen GSB051H Shut Off 15SW 166.00

12997 Hansen GSB076H Shut Off 20SW 200.00

13001 Hansen GSB100H Shut Off 25SW 222.00

13005 Hansen GSB125H Shut Off 32SW 287.00

13009 Hansen GS150H Shut Off 40SW 434.00

Right Angle Stop Valves - Socket Weld (SW) Or Butt Weld (BW)

12994 Hansen ASB051H Shut Off 15SW 169.00

12998 Hansen ASB076H Shut Off 20SW 202.00

13002 Hansen ASB100H Shut Off 25SW 225.00

13006 Hansen ASB125H Shut Off 32SW 309.00

13010 Hansen AS150H Shut Off 40SW 434.00

13014 Hansen AS200H Shut Off 50SW 501.00

13018 Hansen AS251H Shut Off 65SW 672.00

12960 Hansen AW301H Shut Off 80BW 1,000.00

12964 Hansen AW402H Shut Off 100BW 1,296.00

12968 Hansen AW500H Shut Off 125BW 2,191.00

12972 Hansen AW600H Shut Off 150BW 2,533.00

12976 Hansen AW800H Shut Off 200BW 5,379.00

Note: NB for straight through, use with a 45° elbow welded to each branch. The above stop valves are also suitable for HCFCs, HFCs, and other approved refrigerants. Valves larger than 65 mm are Butt Weld. Smaller valves may be of either type.

Hansen Hand Regulating Valves - AmmoniaRealcoldStock No.

Description System Price$ Excl. GST

Angle Or Globe Regulating Valve - Socket Weld, With Cap

13137 Hansen VSB050C Hand Exp 15SW 186.00

13141 Hansen VSB076C Hand Exp 20SW 210.00

13145 Hansen VSB100C Hand Exp 25SW 258.00

13149 Hansen VSB125C Hand Exp 32SW 325.00

13069 Hansen VS150C Hand Exp 40SW 499.00

Hansen Stop Check Valves - AmmoniaRealcoldStock No.

Description System Price$ Excl. GST

Angle Stop/ Check Valve - Socket Weld Or Butt Weld With Cap

12039 Hansen HSCK125C Stop/Check 32SW 768.00

12040 Hansen HSCK150C Stop/Check 40SW 833.00

12041 Hansen HSCK200C Stop/Check 50SW 1,150.00

12042 Hansen HSCK250C Stop/Check 65BW 1,585.00

12043 Hansen HSCK300C Stop/Check 80BW 2,046.00

12044 Hansen HSCK400C Stop/Check 100BW 2,638.00

12045 Hansen HSCK500C Stop/Check 125BW 4,198.00

12046 Hansen HSCK600C Stop/Check 150BW 5,309.00

IN172

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

PRESSURE REGULATORS

Hansen Pressure Regulators RealcoldStock No.

Model Description System Price$ Excl. GST

17382 AR1-20 Main Valve Single Port 20mm (3/4”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

439.00

17383 AR1-25 Main Valve Single Port 25mm (1”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

645.00

17384 AR1-32 Main Valve Single Port 32mm (1 1/4”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

887.00

17385 AR1-40 Main Valve Single Port 40mm (1 1/2”) Regulating Valve Body.

Flange options 11944, 11948, 11947, 11951

1,330.00

17386 AR1-50 Main Valve Single Port 50mm (2”) Regulating Valve Body.

Flange options 11944, 11948, 11947, 11951

1,573.00

17387 AR1-65 Main Valve Single Port 65mm (2 1/2”) Regulating Valve Body.

Flange options 11952, 11962

2,049.00

19763 AR1-80 Main Valve Single Port 80mm (3”) Regulating Valve Body.

Flange options 11956, 11958

2,968.00

17388 AR3-20 Main Valve Three Port 20mm (3/4”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

598.00

17389 AR3-25 Main Valve Three Port 25mm (1”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

792.00

17390 AR3-32 Main Valve Three Port 32mm (1 1/4”) Regulating Valve Body.

Flange options 11929, 11933, 11936, 11932, 11942, 11943

1,046.00

17391 AR3-40 Main Valve Three Port 40mm (1 1/2”) Regulating Valve Body.

Flange options 11944, 11948, 11947, 11951

1,467.00

17392 AR3-50 Main Valve Three Port 50mm (2”) Regulating Valve Body.

Flange options 11944, 11948, 11947, 11951

1,731.00

17393 AR3-65 Main Valve Three Port 65mm (2 1/2”) Regulating Valve Body.

Flange options 11952, 11962

2,209.00

17394 AR3-80 Main Valve Three Port 80mm (3”) Regulating Valve Body.

Flange options 11958, 11956

3,128.00

Note: See page IN176 for flange descriptions.

AR1 Body

AR3 Body

Features

• AR Series are base valve bodies which can be made into a variety of Pilot and Solenoid valve combinations. The head will accept either Hansen or Danfoss Pilots as required, and will also operate with a variety of proprietary controllers.

• All valves are spring closing, and have Teflon seats, with V-port modulation.

• Safe Working Pressure 2758 kPa G (400 psig).

• Operating Temperature -40°C to 115°C (-60°F to 240°F).

• Suitable for Ammonia, Carbon Dioxide, HCFCs, HFAs, and other approved refrigerants.

• Suitable for use with suction gas, liquid, defrost relief, discharge gas, and other applications.

• Additionally, Realcold offers complete Solenoid and Control Valves according to your application.

• Contact Realcold to advise on suitable control combinations.

IN173

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

CONTROL VALVE PILOTS

Hansen Individual Pilot ApplicationsOption Description Range

0 -

150

psig

(0

to 1

0 ba

r)

30 -

300

psig

(+

2 to

+21

bar

)

100

to 5

50 p

sig

(6 -

38

bar)

30 to

450

psi

g (0

to 3

1 ba

r)

20”

to 1

30 p

sig

(-0.

67 to

+9

bar)

S Electric Shut-Off

Controls Pressure when electronically energised; closed when not energised. For temperature control and defrost, or similar uses. Specify Voltage, Range and Special Variation if required.

ü ü ü ü ü

B Electric Wide Opening

Controls pressure when not electrically energized; open when energized. For defrost regulation or heat recovery and wide opening for maximum cooling or similar. Specify Voltage, Range and Special Variation if required.

ü ü ü ü ü

D Dual Pressure Regulator

Controls at lower pressure when electrically energised, at higher pressure when not energized. Used for two pressure (temperature) control or defrost pressure relief and pressure (temperature control. Specify Voltage, Range and Special Variation if required.

ü ü ü ü ü

L Differential Pressure

For pump relief, oil control or any differential controlü

O Outlet Pressure

Opens as outlet pressure drops. For hot gas bypass to suction, crankcase pressure control or for other receiver pressure control.

ü ü

K Reseating Relief

Defrost relief or high to low system relief. Set and tagged. Specify setting or otherwise setting will be at 70 psig (4.8 bar)

ü ü ü ü

R Regulator Only with External Connection for Remote Pilot

Enables a remote pressure source to be introduced to the regulator via a pilot line (replaces a pilot).

P Pneumatically Controlled

Air pressure or other pressure in bonnet raises inlet pressure at 1:1 ratioü

Q Electronic Control Module

Precise temperature control or liquid chiller control. For indoor or outdoor use. Simple design; 4-20 mA control. Transformer included. Control range 0 - 87 psig.

ü

M Electric Motor Compensated

Commonly used for precise room temperature control or liquid chiller control. A motor changes regulator pressure setting in accordance with temperature controller. Includes control module, Cam, motor bracket and Penn motor 4020 mA standard. (Honeywell motor available)

ü ü

M3B Stopping Plug (Straight Through)

To be used in a Control Port when the port is not utilised.ü ü ü ü ü

M3S Stopping Plug (Stopping)

To be used in a Control Port when the port is not utilised.ü ü ü ü ü

M3O

MS

M3S

M3B

M3L

M3K

IN174

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

CONTROL VALVE PILOTS

Hansen Pressure PilotsRealcoldStock No.

Model Description System Price$ Excl. GST

11794 75-1097 Hansen M3 Pilot Range A (0 To 10 Bar); Inlet Pressure Control Module For All Pressure Regulators

416.00

11795 75-1098 Hansen M3 Pilot Range B (2 To 21 Bar); Inlet Pressure Control Module For All Pressure Regulators

416.00

17401 75-1099 Hansen M3 Pilot Range V (-0.67 To 9 Bar); Inlet Pressure Control Module For All Pressure Regulators

650.00

18932 75-1126 Hansen M3W Pilot Range A (0 To 10 Bar); Compact Inlet Control Module For All Pressure Regulators Up To And Including 32 mm

416.00

11796 75-1100 Hansen M3O Pilot Range V (-0.67 To 9 Bar); Outlet Pressure Control Module 804.00

11797 75-1101 Hansen M3O Pilot Range B (2 To 21 Bar); Outlet Pressure Control Module 804.00

11798 75-1103 Hansen M3K Pilot Range A (0 To 10 Bar); Reseating Relief Control Module For 40 mm Press Regulator And Above

500.00

11799 75-1104 Hansen M3K Pilot Range B (2 To 21 Bar); Reseating Relief Control Module For All Press Regulators

500.00

13961 75-1081 Hansen M3P Pilot Range A (0 To 10 Bar G); M3P/L Pneumatically Compensated Or Differential Pressure; Control Module For All Press Regulators

553.00

17402 75-1064 Hansen M3B Through Blanking Plug 27.85

17403 75-1063 Hansen M3S Stopping Blanking Plug 27.85

Danfoss Pressure PilotsRealcoldStock No.

Model Description System Price$ Excl. GST

16736 027B110000 Danfoss (LP) Pilot Valve 0 To 7 Bar Range; Constant Press For PM Main Valves; 17 Bar MWP; 0.4m^3/H KV

POA

16735 027B107000 Danfoss CVC (LP) Pilot Valve 0 To 7 Bar Range; Outlet Pressue Pilot; 17 Bar MWP; 0.4m^3/H KV

POA

16739 027B111000 Danfoss CVT Pilot Valve -40 To 0 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV

POA

16740 027B111100 Danfoss CVT Pilot Valve -10 To 25 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV

POA

16741 027B111200 Danfoss CVT Pilot Valve 20 To 60 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV

POA

16743 027B114000 Danfoss CVQ Pilot Valve 0 To 6 Bar Range; Electronically Operated Constant Press For PM Main Valves; 17 Bar MWP; 0.45m^3/H KV

POA

16744 027B114100 Danfoss CVQ Pilot Valve 1.7 To 8 Bar Range; Electronically Operated Constant Press For PM Main Valves; 17 Bar MWP; 0.45m^3/H KV

POA

16745 027B116000 Danfoss CVP (HP) Pilot Valve 4 To 22 Bar Range; Constant Press For Pm Main Valves + CVH Housing; 28 Bar Mwp; 0.4m^3/H KV

POA

16746 027B116200 Danfoss CVPP (HP) Pilot Valve 4 To 22 Bar Range; Differential Press For PM Main Valves; 28 Bar MWP; 0.4m^3/H KV

POA

Range A 0 - 150 psig (0 to 10 Bar)

Range B 30 - 300 psig (+2 to +21 Bar)

Range C 100 to 550 psig (6 - 38 Bar)

Range D 30 to 450 psig (0 to 31 Bar)

Range V 20” to 130 psig (-0.67 to +9 Bar)

IN175

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

STRAINERS

Hansen Strainers/Filters - SteelHansen Strainers have a stainless steel screen, 60 mesh (233 micron rating). Groove inlet, tongue outlet. Safe Working Pressure: 2758 kPa (400 psig). Applications include liquid lines, hot gas lines, suction lines, and oil lines. Strainers are supplied ready to be close-coupled to solenoid valves, pressure regulators, etc. For installation as a separate unit, a flange installation kit is required (see below).

RealcoldStock No.

Model Description System Price$ Excl. GST

12051 ST050 To fit 13 mm Port (less flanges) 118.00

12056 ST100 To fit 20 mm, 25 mm, 32 mm Port (less flanges) 306.00

12069 ST200 To fit 40 mm, 50 mm Port (less flanges) 675.00

12078 ST250 To fit 65 mm Port (less flanges) 940.00

12079 ST300 To fit 80 mm Port (less flanges) 1,585.00

12080 ST400 To fit 100 mm Port (less flanges) 1,585.00

Hansen Flange Conversion KitHansen Flange Conversion Kits include bolts, gaskets, and female adaptor ring, to allow a strainer to be installed as a separate item.

RealcoldStock No.

Description System Price$ Excl. GST

17405 To suit ST050 Strainer 59.75

17406 To suit ST100 Strainer 77.25

17407 To suit ST200 Strainer 183.00

17408 To suit ST250 Strainer 211.00

Herl Angle Strainers/Filters - SteelRealcoldStock No.

Description System Price$ Excl. GST

17323 32 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16912 40 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16913 50 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16914 65 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16915 80 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16916 100 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

17317 125 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16917 150 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

16918 200 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA

IN176

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

FLANGES AND ADAPTOR RINGS

Hansen Flanges & Flange KitsThe Hansen flange system is generally interchangeable for Parker Refspec, Henry, and York/Frick flanges. A flange kit is two male (tongued) flanges (of the same size and style) to suit a Hansen flanged valve. Gaskets, bolts, and nuts are provided with the valve, or can be purchased separately.

RealcoldStock No.

Description System Price$ Excl. GST

Item Connection Vendor Model No. Bolts Per Flange

11925 Flange Kit 1/2" FPT # 050 (2-Bolt) 69.05

11923 Flange Kit 1/2" SW # 050 (2-Bolt) 69.05

11926 Flange Kit 3/4" SW # 050 (2-Bolt) 69.05

11929 Flange Kit 3/4" SW # 100 (2-Bolt) 89.65

11933 Flange Kit 1" SW # 100 (2-Bolt) 89.65

11936 Flange Kit 1.1/4" SW # 100 (2-Bolt) 89.65

11939 Flange Kit 1.1/2" SW # 100 (2-Bolt) 79.35

11944 Flange Kit 1.1/2" SW # 200 (4-Bolt) 143.00

11948 Flange Kit 2" SW # 200 (4-Bolt) 143.00

11952 Flange Kit 2.1/2" SW # 250 (4-Bolt) 252.00

11919 Flange Kit 5/8" OD # 050 (2-Bolt) 88.60

11932 Flange Kit 7/8" OD # 100 (2-Bolt) 128.00

11942 Flange Kit 1.1/8" OD # 100 (2-Bolt) 128.00

11943 Flange Kit 1.3/8" OD # 100 (2-Bolt) 128.00

11947 Flange Kit 1.5/8" OD # 200 (4-Bolt) 184.00

11951 Flange Kit 2.1/8" OD # 200 (4-Bolt) 184.00

11955 Flange Kit 2.5/8" OD # 250 (4-Bolt) 306.00

Hansen Adaptor RingsRealcoldStock No.

Description System Price$ Excl. GST

Female Adaptor Rings. Female adaptor rings are used at the outlet of strainers installed as separate flange units.

17374 FAR 050 Female Adaptor Ring 27.85

17375 FAR 100 Female Adaptor Ring 27.85

17376 FAR 200 Female Adaptor Ring 112.00

17377 FAR 250 Female Adaptor Ring 143.00

Male Adaptor Rings. Male adaptor rings are used to close-couple HCK4 or HCK1 check valves to the outlet of valves and regulators.

17378 MAR 050 Male Adaptor Ring 35.05

17379 MAR 100 Male Adaptor Ring 35.05

17380 MAR 200 Male Adaptor Ring 59.75

17381 MAR 250 Male Adaptor Ring 71.10

Henry Flange Union KitsRealcoldStock No.

Description System Price$ Excl. GST

Item Connection Vendor Model No. Bolts Per Flange

17685 Flange Kit 1/2" SW 02SW-1x1/2 (2-Bolt) 206.00

17686 Flange Kit 3/4" SW 02SW-1x3/4 (2-Bolt) 217.00

17687 Flange Kit 1" SW 02SW-1 (2-Bolt) 206.00

17688 Flange Kit 1.1/4" SW S2SW-1-1/4 (4-Bolt) 296.00

17689 Flange Kit 1.1/2" SW S2SW-2x1-1/2 (4-Bolt) 352.00

17690 Flange Kit 2" SW S2SW-2 (4-Bolt) 335.00

17691 Flange Kit 2.1/2" SW S2SW-2-1/2 (4-Bolt) 391.00

17692 Flange Kit 3" SW S2SW-3 (4-Bolt) 446.00

17693 Flange Kit 4" SW S2SW-4 (4-Bolt) 525.00

Note: The HENRY flange system consists of 1 Female and 1 Male Flange, complete with bolts and nuts.

IN177

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

COMPLETE VALVE COMBINATION

Hansen Control Valves - SteelCosts for larger valves are available on request. We are able to make up most valves up to 80 mm from our stock of Control Valve bodies and pilots. Non-stock pilots can be supplied within 5-7 working days from placement of order however there may be additional courier costs.

Many Danfoss pilots and electronic controllers are also available for substitution if required. The Hansen modular control head is designed to fit both ranges of control pilots.

RealcoldStock No.Without Strainer

RealcoldStock No .With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

11817 - HA2B Small Pressure Regulator 1/2" SW 462.00 -

11411 11415 HA4A-20 Modular Pressure Regulator 3/8” SW 665.00 972.00

11431 11435 HA4A-25 Modular Pressure Regulator 1” SW 857.00 1,163.00

11444 11448 HA4A-32 Modular Pressure Regulator 1 1/4” SW 1,110.00 1,416.00

11458 11462 HA4A-40 Modular Pressure Regulator 1 1/2” SW 1,608.00 2,283.00

11472 11476 HA4A-50 Modular Pressure Regulator 2” SW 1,849.00 2,524.00

11480 11483 HA4A-65 Modular Pressure Regulator 3” SW 2,436.00 3,376.00

11486 11490 HA4A-80 Modular Pressure Regulator 3” SW 3,384.00 4,519.00

11506 11510 HA4AS-20 Electric Shut Off Regulator 3/8” SW 1,226.00 1,532.00

11526 11530 HA4AS-25 Electric Shut Off Regulator 1” SW 1,519.00 1,825.00

11539 11543 HA4AS-32 Electric Shut Off Regulator 1 1/4” SW 1,676.00 1,982.00

11553 11557 HA4AS-40 Electric Shut Off Regulator 1 1/2” SW 2,171.00 2,845.00

11567 11571 HA4AS-50 Electric Shut Off Regulator 2” SW 2,412.00 3,086.00

11575 11578 HA4AS-65 Electric Shut Off Regulator 3” SW 2,999.00 3,938.00

11581 11585 HA4AS-80 Electric Shut Off Regulator 3” SW 3,950.00 5,085.00

11601 11605 HA4AB-20 Electric Wide Opening Regulator 3/8” SW 1,224.00 1,530.00

11621 11625 HA4AB-25 Electric Wide Opening Reg 1” SW 1,420.00 1,726.00

11634 11638 HA4AB-32 Electric Wide Opening Reg 1 1/4” SW 1,672.00 2,016.00

11648 11659 HA4AB-40 Electric Wide Opening Reg 1 1/2” SW 2,169.00 2,843.00

11662 11666 HA4AB-50 Electric Wide Opening Reg 2” SW 2,412.00 3,086.00

11670 11675 HA4AB-65 Electric Wide Opening Reg 21/2” SW 2,997.00 3,936.00

11676 11680 HA4AB-80 Electric Wide Opening Reg 3” SW 3,946.00 5,081.00

11696 11700 HA4AD-20 Dual Pressure Regulator 3/8” SW 1,696.00 2,002.00

11716 11720 HA4AD-25 Dual Pressure Regulator 1” SW 1,887.00 2,193.00

11729 11733 HA4AD-32 Dual Pressure Regulator 1 1/4” SW 2,142.00 2,486.00

11743 11747 HA4AD-40 Dual Pressure Regulator 1 1/2” SW 2,638.00 3,313.00

11757 11761 HA4AD-50 Dual Pressure Regulator 2” SW 2,881.00 3,556.00

11765 11768 HA4AD-65 Dual Pressure Regulator 3” SW 3,465.00 4,405.00

11771 11775 HA4AD-80 Dual Pressure Regulator 3” SW 4,416.00 5,551.00

11822 - HA2BK-15 Reseating Relief 1/2" SW 553.00 -

14055 - HA4AK(A)-20 Reseating Relief 1” SW 754.00 -

17094 - HA4AK(A)-25 Reseating Relief 1” SW 948.00 -

17095 - HA4AK(B)-32 Reseating Relief 11/4” SW 1,201.00 -

HA4A HA4ABHA2B

IN178

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

SOLENOID VALVES

Hansen Solenoid Valves - Lower CapacityRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

10925 10929 HS6-4 Pilot Operated Solenoid 3/8" SW 388.00 492.00

13936 10953 HS8A-13 Pilot Operated Solenoid 1/2” SW 461.00 564.00

10965 10969 HS8A-13 Pilot Operated Solenoid 3/4SW 461.00 564.00

10973 10977 HS7-20 Pilot Operated Solenoid 3/4 SW 572.00 842.00

11033 11037 HS7-25 Pilot Operated Solenoid 1” SW 832.00 1,102.00

11075 11079 HS7-32 Pilot Operated Solenoid 11/4”SW 1,027.00 1,297.00

Hansen Solenoid Valves - Higher CapacityRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

11105 11109 HS4A-20 Pilot Operated Solenoid 3/8” SW 712.00 982.00

11165 11169 HS4A-25 Pilot Operated Solenoid 1” SW 922.00 1,192.00

11207 11211 HS4A-32 Pilot Operated Solenoid 1 1/4” SW 1,115.00 1,386.00

11237 11241 HS4A-40 Pilot Operated Solenoid 1 1/2” SW 1,564.00 2,161.00

11279 11283 HS4A-50 Pilot Operated Solenoid 2” SW 1,714.00 2,616.00

11303 11307 HS4A-65 Pilot Operated Solenoid 2 1/2” SW 2,670.00 3,610.00

11345 11349 HS4A-80 Pilot Operated Solenoid 3” SW 3,877.00 5,011.00

Hansen Features & Selection

• All Hansen valves are spring closing and have Teflon seats.

• Safe Working Pressure 2758 kPag (400 psig)

• MOPD 2068 kPag (300 psig)

• Operating Temperature -50°C to +115°C (-60°F to +240°F)

• Suitable for ammonia, Carbon Dioxide, HCFCs, HFAs, and other approved refrigerants. For special duties such as Carbon Dioxide, please contact Realcold Ltd.

• All valves supplied with 230V 50 Hz coil, complete with DIN plug. Coils are also available in 115VAC, 24VAC and 24VDC and can be changed for a nominal charge of $15.00 per coil. For non-DIN coils and Conduit Fitting coils please refer to Realcold.

• All valves supplied as standard with Socket Weld (SW) flanges to suit Carbon Steel ASTM A106 or API line pipe. Can also be supplied with Weld Neck, FPT (Female Pipe Thread) or ODS connections to suit Copper Pipe. Flanges may be sized slightly larger or smaller than the valves dependent on application.

• Strainers, either close coupled or separate, are available - see page IN175

IN179

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

PRESSURE RELIEF, GAUGE & TRANSDUCER VALVES

Hansen Steel Pressure Relief ValvesRealcoldStock No.

Model Size Connections Pressure Settings Cap Ratingslbs Air/Minute

System Price$ Excl. GST

Inlet Outlet PSI kPa

12821 H5601 1/2" FPT 1" FPT 150 1034 35.8 312.00

12827 H5613 1" FPT 1.1/4" FPT 150 1034 53 659.00

12830 H5604 1.1/4" FPT 1.1/2" FPT 150 1034 72 1,219.00

12822 H5601 1/2" FPT 1" FPT 250 1725 57.7 312.00

12828 H5613 1" FPT 1.1/4" FPT 250 1725 85.4 659.00

12831 H5604 1.1/4" FPT 1.1/2" FPT 250 1725 116.1 1,219.00

12823 H5601 1/2" FPT 1" FPT 300 2070 - 312.00

12829 H5613 1" FPT 1.1/4" FPT 300 2070 - 659.00

12832 H5604 1.1/4" FPT 1.1/2" FPT 300 2070 - 1,219.00

Gauge Valves, AngleRealcoldStock No.

Description System Price$ Excl. GST

Hansen

11793 Hansen HGV1 Gauge Valve 1/4" MPT long neck screwed male and female 83.45

12780 Hansen H7771 Gauge Valve1/4" MPT Screwed male and female C/W Seal cap 84.50

12783 Hansen H7773 Gauge Valve 3/8" MPT Screwed male and female C/W Seal cap 96.85

12784 Hansen H7774 Gauge Valve 3/8" FPT Screwed female C/W Seal cap 95.80

Henry

19561 Henry 7773 Gauge Valve 3/8" NPT Screwed male and female 143.00

19571 Henry 7771 Gauge Valve 1/4" NPT Screwed male and female 92.70

17694 Henry 7775 Gauge Valve 1/2" NPT Screwed male and female 167.00

Transducer Valves Hansen & HenryRealcoldStock No.

Description System Price$ Excl. GST

12779 Hansen H9490 Transducer Valve; 8 mm (1/4in) MPT Inlet x FPT Gauge Port x FPT Transducer Port; With Seal Cap

129.00

Three Way Hand Shut-Off ValvesRealcoldStock No.

Description System Price$ Excl. GST

12833 Hansen H8021 Steel 1/2" FPT 326.00

12835 Hansen H8024 Steel 1" FPT 543.00

12836 Hansen H8025 Steel 1 1/4" FPT 758.00

Industrial Pressure GaugesRealcoldStock No.

Description Scale System Price$ Excl. GST

17700 63 mm -100 to + 1000 kPa 1/4" NPT LP Gauge 204.00

17701 63 mm -100 to + 2400 kPa 1/4" NPT HP Gauge 204.00

17702 100 mm -100 to + 900 kPa 1/4" NPT LP Gauge 403.00

17703 100 mm -100 to + 2400 kPa 1/4" NPT HP Gauge 403.00

11791 Hansen Ammonia Gauge GA1M -1 to 11 Bar 217.00

11792 Hansen Ammonia Gauge GA2M 01 to 21 Bar 217.00

Note: Stainless steel case, stainless steel Bourdon tube, glycerine filled, with kPa and temperature scales

IN180

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

FLOAT CONTROLS, LEVEL PROBES & SWITCHES, SIGHT GLASSES

Hansen Float Controls (See Spares Section for Spare Switch only)

RealcoldStock No.

Model Description System Price$ Excl. GST

12874 HLLE Float Switch Assembly 3/4” FPT/1” Butt Weld 1,270.00

Hansen Techni-Level® Level Transducer ProbesRealcoldStock No.

Model Description System Price$ Excl. GST

12916 VLT-04 Active Probe Length 1020 mm 3,175.00

12917 VLT-06 Active Probe Length 1525 mm 3,389.00

12918 VLT-08 Active Probe Length 2030 mm 3,691.00

12919 VLT-10 Active Probe Length 2540 mm 4,108.00

12913 VLT-XX Active Probe Length Cut to Suit Custom Length POA

Henry Liquid Level SwitchRealcoldStock No.

Model Description System Price$ Excl. GST

17695 Henry 9420-1 1 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Closed

380.00

17696 Henry 9420A-1 1 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Open

380.00

17925 Henry 9420 1/2 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Closed

281.00

19614 Henry 9420-1 1/2 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Open

272.00

Industrial Sight Glasses - Steel*RealcoldStock No.

Model Description System Price$ Excl. GST

12321 Phillips 1100-R Level Eye Assembly, Bulls-Eye Lens (50 mm long housing) 247.00

12336 Phillips 1100 Level Eye Assembly, Clear Lens (50 mm long housing) 274.00

12947 Hansen H1100-R See-Level Assembly (82.5 mm long universal housing) 242.00

12948 Hansen H1100-RN See-Level Assembly (82.5 mm long universal housing) C/W Frost Shield

290.00

17200 Phillips 1101 Clear Lens 137.00

17311 Phillips 1101-R Bulls-Eye Lens 110.00

17310 Phillips 1105L Long Frost Shield (c/w 1106 'O' ring) 128.00

17546 Phillips 1103 Gasket 4.15

17547 Phillips 1104 Gasket 4.15

17052 Phillips 1102 Retainer 187.00

19849 Hansen 77-1002 Bulls-Eye / Reflex Lens Kit including Gaskets 92.70

19851 Hansen 77-0487 Retainer ring 77.25

19023 Hansen 77-1003 Hansen Standard Frost Shield (c/w "O" Ring) 64.90

18053 AC & R SG1004 1/2" MPT Sight Glass - Clear 26.80

17548 AC & R SG1008 1" MPT Sight Glass - Clear 34.00

14011 AC & R SG1108 1" MPT Sight Glass - Reflex 34.00

17697 AC & R SG1208 1"MPT Sight Glass with Ball 49.45

17698 AC & R SG1212 1 1/2"MPT Sight Glass with Ball 106.00

17549 AC & R SG1016 2" MPT Sight Glass - Clear 134.00

19562 Henry LI48A 1/2 Double Port Indicator 1/2” (15 mm) FPT 163.00

19563 Henry LI48A 3/4 Double Port Indicator 3/4” (20 mm) FPT 168.00

19564 Henry LI48A 1 Double Port Indicator 1” (25 mm) FPT 174.00

* Sight glasses not suitable for Ammonia Refrigeration Systems. Clear Lenses are not suitable for use with Ammonia. They may be used for Freon systems and Oil lines only. All lenses used for Ammonia must be of the Bulls Eye (RealFlex) type. If in doubt, please contact your local branch.

IN181

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

AUTO PURGERS

Hansen Mini Auto Purger NEAPAuto Purgers are available on Indent only. For selection and delivery please contact your local branch. Please specify model number, refrigerant and voltage.

RealcoldStock No.

Model Description System Price$ Excl. GST

Indent NEAP Mini Auto Purger - Ammonia 13,346.00

Indent VPM Valve Package Ammonia 1,884.00

Indent NEAPF Mini Auto Purger - Halocarbons 14,182.00

Indent VPMF Valve Package Halocarbons 3,068.00

Hansen Auto Purger APMRealcoldStock No.

Model Description System Price$ Excl. GST

Indent APM Auto Purger APM - 4-Points Ammonia 18,375.00

Indent VPM Valve Package Ammonia 1,664.00

Indent APMF Auto Purger APM - 4-Points Halocarbons 20,786.00

Indent VPMF Valve Package Halocarbons 3,068.00

Hansen Deluxe Auto Purger APMVarious additional options are available including Insulation, Water Conditioning Housing and Relief Valves. For details of the available options and for Halocarbon Refrigerant Auto-Purgers, please contact us.

RealcoldStock No.

Model Description System Price$ Excl. GST

Indent AP08 Auto Purger Deluxe - 8-Points 34,842.00

Indent AP16 Auto Purger Deluxe - 16-Points 39,779.00

Indent AP24 Auto Purger Deluxe - 24-Points 45,239.00

Hansen Plus Auto Purger APMSuitable for Ammonia Refrigeration Systems only.

RealcoldStock No.

Model Description System Price$ Excl. GST

Indent APP08 Auto Purger Plus - 8-Points 55,367.00

Indent APP16 Auto Purger Plus - 16-Points 61,540.00

Indent APP24 Auto Purger Plus - 24-Points 68,233.00

Mini Auto Purger NEAP

Auto Purger APP

Auto Purger AP

Auto Purger APM

IN182

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

AUTO PURGER SPARES

Hansen Auto Purger SparesRealcoldStock No.

Model Vendor Part No. Description System Price$ Excl. Gst

19766 AP 20-1198 Metering Valve Seal Kit 77.00

19765 AP 20-1214 Check Valve Seal Kit 46.00

19121 AP 20-1441 Power Element Level Control 1,617.00

19467 AP 20-1473 Counter 6-Digit 230V 1,383.00

19869 AP 20-1739 Power Element 230v 1,602.00

W99D83 AP 20-1772 Water Bubbler Assembly 558.00

19555 AP 20-1773 Purger Control Board Exc Connector 230V POA

19466 AP 70-0208 Liquid Line Solenoid Valve HS2 347.00

19767 AP HS2B-1 Solenoid Valve HS2 1/4" FPT 277.00

19870 AP - Level Control Flange Gaskets 16.50

W9209 APM 20-1836 Control Board 3,530.00

19656 APM 20-1857 Pressure Transducer 1,771.00

19879 APM 70-1068 Seal Orifice Kit for Solenoids B and C 92.00

19880 APM 70-1069 Seal Orifice Kit for Solenoid A 92.00

19417 APM 77-0534 High Side Level Sensor 1,161.00

18014 APM 77-0535 Level Sensor for Low side 861.00

19823 NEAP 20-1183 Check Valve 1PSID 484.00

60037 NEAP 20-1187 Check Valve Ball 12.00

19542 NEAP 20-1952 Metering Cartridge "O" Ring 9.00

19537 NEAP 20-2166 Float Ball Seat "O" Ring 15.00

19538 NEAP 20-2167 Vessel Cover "O" Ring 40.00

19825 NEAP 20-2199 Check Valve Assy 80 PSID 274.00

19539 NEAP 20-2200 Temperature Valve Assembly Kit 373.00

19824 NEAP 20-2200 Temperature Vavle Assy Kit 373.00

19535 NEAP 20-2201 Float Ball Plunger 256.00

19536 NEAP 20-2202 Float Ball Seat 268.00

19475 NEAP 20-2204 Check Valve Kit 225PSI 148.00

19826 NEAP 20-2207 Sight Glass 36.05

19543 NEAP 70-0065 Flange and Pilot Port Gasket 19.00

19541 NEAP 72-0066 NEAP Solenoid Tube Gasket 22.00

19915 NEAP 77-0036 Float Ball 185.00

19540 NEAP 78-1010 NEAP Strainer Kit 99.00

Note: Auto Purger Spares are available only as Indent Items. Price includes delivery via FedEx Courier. Parts are normally delivered within 5-10 working days from receipt of order. For a full list of available parts refer to the Hansen Collection of Instructions or refer to your local branch.

IN183

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

CHECK VALVES

Hansen Check Valves - AmmoniaRealcoldStock No.With Flanges or Butt Weld

RealcoldStock No.With Male Adaptor Ring

Description RealcoldStock No.

With Flanges or Butt Weld

RealcoldStock No.

With Male Adaptor Ring

Hansen HCK4 In-Line Check Valves - Ammonia

11964 11966 Hansen HCK4-2 15SW 232.00 197.00

11969 11970 Hansen HCK4-3 20SW 263.00 209.00

11972 11973 Hansen HCK4-4 25SW 325.00 270.00

11975 11977 Hansen HCK4-5 32SW 451.00 396.00

11978 - Hansen HCK4-6 32SW 363.00 -

11981 11982 Hansen HCK4-7 40SW 590.00 506.00

11984 11986 Hansen HCK4-8 50SW 659.00 576.00

11990 11991 Hansen HCK4-9 65SW 973.00 793.00

11993 11995 Hansen HCK4-0 80SW 1,259.00 1,046.00

11999 12001 Hansen HCK4-1 100SW 2,032.00 1,696.00

Hansen Hck1 Piston Check Valves - Ammonia

12005 Hansen HCK1-20 20SW 573.00

12009 Hansen HCK1-25 25SW 604.00

12013 Hansen HCK1-32 32SW 872.00

12017 Hansen HCK1-40 40SW 1,137.00

12021 Hansen HCK1-50 50SW 1,219.00

12025 Hansen HCK1-65 65SW 1,575.00

12029 Hansen HCK1-80 80SW 2,180.00

12033 Hansen HCK1-100 100SW 3,373.00

12037 Hansen HCK1W-125 BW PISTON CHK 6,092.00

12038 Hansen HCK1W-150 BW PISTON CHK 10,117.00

Modentic Wafer Duo Check Valves - AmmoniaDual Plate Check Valve; Mv-1221 ANSI 150 or 300lbs; Body & Disc CF8M; Plate S/S 316. ANSI150lb Valves come with Metal to Metal Seat. The 300lb Valves come with Neoprene seat with chemical resistance to Liquid and Gaseous Ammonia and mineral refrigerant oils at the normal temperatures experienced in industrial refrigeration. For other refrigerants and oil combinations, please refer to your local branch.

RealcoldStock No.

Description System Price$ Excl. Gst

19445 Modentic 50NB CHK VLV ANSI150 POA

19446 Modentic 65NB CHK VLV ANSI150 POA

19447 Modentic 80NB CHK VLV ANSI150 POA

19448 Modentic 100NB CHK VLV ANSI150 POA

19449 Modentic 125NB CHK VLV ANSI150 POA

19450 Modentic 150NB CHK VLV ANSI150 POA

19451 Modentic 200NB CHK VLV ANSI150 POA

19452 Modentic 250NB CHK VLV ANSI150 POA

19453 Modentic 300NB CHK VLV ANSI150 POA

19454 Modentic 50NB CHK VLV ANSI300 POA

19455 Modentic 65NB CHK VLV ANSI300 POA

19456 Modentic 80NB CHK VLV ANSI300 POA

19457 Modentic 100NB CHK VLV ANSI300 POA

19458 Modentic 125NB CHK VLV ANSI300 POA

19459 Modentic 150NB CHK VLV ANSI300 POA

19460 Modentic 200NB CHK VLV ANSI300 POA

19461 Modentic 250NB CHK VLV ANSI300 POA

19462 Modentic 300NB CHK VLV ANSI300 POA

IN184

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

MULTI PORT VALVES

Hansen Multi Port Valves Sample Configurations for Common Valve ApplicationsThe Hansen MVP Multi Valve Platform is well suited for multiple applications including Pumped Liquid Feed, liquid make-up to flooded and recirculation vessels, liquid injection for compressors, hot-gas defrost to evaporators, and evaporator pressure control. Up to six functions are possible: stop, strainer, control valve (solenoid / pressure regulator / motorised valve), check, hand expansion and stop all in one dynamic multi-solution valve. See the Hansen MVP Multi Valve Platform brochure for more information.

Application Position 1 Position 2 Position 3 Position 4

Liquid Feed Shut-Off Strainer Solenoid Stop Check/Hex

Liquid Feed, Motorized Shut-Off Strainer Motor Stop Check/Hex

Liquid Make-Up Shut-Off Strainer Solenoid Hand Expansion

Liquid Make-Up, Motorized Shut-Off Strainer Motor Shut-Off

Hot Gas Valve Shut-Off Strainer Solenoid Shut-Off

Hot Gas Valve, Motorized Shut-Off Strainer Motor Shut-Off

Defrost Relief Shut-Off Strainer Regulator Shut-Off

Defrost Relief/Wide Open Shut-Off Strainer Regulator Shut-Off

MVP with Solenoid Control ValveSIZE Port SW

ConnectionModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. Gst

MVP20 3/4" 3/4" MVP-1 1,546.00 MVP-2 1,556.00 MVP-3 1,767.00 MVP-4 1,757.00 MVP-5 1,521.00

1" MVP-1 1,600.00 MVP-2 1,639.00 MVP-3 1,850.00 MVP-4 1,811.00 MVP-5 1,548.00

1-1/4" MVP-1 1,798.00 MVP-2 1,816.00 MVP-3 2,027.00 MVP-4 2,009.00 MVP-5 1,647.00

MVP25 1" 1" MVP-1 1,833.00 MVP-2 1,872.00 MVP-3 2,142.00 MVP-4 2,102.00 MVP-5 1,839.00

1-1/4" MVP-1 2,031.00 MVP-2 2,049.00 MVP-3 2,318.00 MVP-4 2,301.00 MVP-5 1,939.00

MVP32 1-1/4" 1-1/4" MVP-1 2,246.00 MVP-2 2,263.00 MVP-3 2,649.00 MVP-4 2,631.00 MVP-5 2,269.00

MVP40 1-1/2" 1-1/2" MVP-1 3,392.00 MVP-2 3,469.00 MVP-3 3,965.00 MVP-4 3,888.00 MVP-5 3,381.00

2" MVP-1 3,550.00 MVP-2 3,625.00 MVP-3 4,121.00 MVP-4 4,046.00 MVP-5 3,460.00

2-1/2" MVP-1 3,953.00 MVP-2 4,231.00 MVP-3 4,727.00 MVP-4 4,449.00 MVP-5 3,661.00

MVP50 2" 2" MVP-1 3,720.00 MVP-2 3,795.00 MVP-3 4,359.00 MVP-4 4,283.00 MVP-5 3,698.00

2-1/2" MVP-1 4,123.00 MVP-2 4,401.00 MVP-3 4,965.00 MVP-4 4,686.00 MVP-5 3,899.00

MVP with Pressure Regulator Control ValveSIZE Port SW

ConnectionModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. GstModel System Price

$ Excl. Gst

MVP20 3/4" 3/4" MVP-1A 1,139.00 MVP-2A 1,146.00 MVP-3A 1,315.00 MVP-4A 1,308.00 MVP-5A 1,119.00

1" MVP-1A 1,182.00 MVP-2A 1,213.00 MVP-3A 1,382.00 MVP-4A 1,351.00 MVP-5A 1,140.00

1-1/4" MVP-1A 1,340.00 MVP-2A 1,354.00 MVP-3A 1,523.00 MVP-4A 1,509.00 MVP-5A 1,219.00

MVP25 1" 1" MVP-1A 1,334.00 MVP-2A 1,366.00 MVP-3A 1,581.00 MVP-4A 1,550.00 MVP-5A 1,339.00

1-1/4" MVP-1A 1,493.00 MVP-2A 1,507.00 MVP-3A 1,722.00 MVP-4A 1,708.00 MVP-5A 1,419.00

MVP32 1-1/4" 1-1/4" MVP-1A 1,692.00 MVP-2A 1,706.00 MVP-3A 2,014.00 MVP-4A 2,001.00 MVP-5A 1,711.00

MVP40 1-1/2" 1-1/2" MVP-1A 2,603.00 MVP-2A 2,664.00 MVP-3A 3,061.00 MVP-4A 3,000.00 MVP-5A 2,594.00

2" MVP-1A 2,729.00 MVP-2A 2,789.00 MVP-3A 3,186.00 MVP-4A 3,126.00 MVP-5A 2,657.00

2-1/2" MVP-1A 3,051.00 MVP-2A 3,274.00 MVP-3A 3,671.00 MVP-4A 3,448.00 MVP-5A 2,818.00

MVP50 2" 2" MVP-1A 2,918.00 MVP-2A 2,978.00 MVP-3A 3,429.00 MVP-4A 3,369.00 MVP-5A 2,900.00

2-1/2" MVP-1A 3,240.00 MVP-2A 3,463.00 MVP-3A 3,914.00 MVP-4A 3,691.00 MVP-5A 3,061.00

IN185

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

MOTORISED VALVES

Hansen Motorised Valves - Model HMSVSuitable for pressure, temperature, or level control. Drop-in replacement for same port size Hansen valve. Model HMSV: The full ported valve series is best suited for applications requiring slow open/close operation only.

Less Strainer with Flanges Nominal Size

Flow Factor (CV)

Standard, System Price$ Excl. Gst

Power Close, System Price$ Excl. Gst

Hansen HMSV Motorised Valve 20 mm 20 mm 6.4 4,543.00 6,097.00 Hansen HMSV Motorised Valve 25 mm 25 mm 11.7 4,738.00 6,291.00 Hansen HMSV Motorised Valve 32 mm 32 mm 16.4 4,997.00 6,550.00 Hansen HMSV Motorised Valve 40 mm 40 mm 33 5,490.00 7,043.00 Hansen HMSV Motorised Valve 50 mm 50 mm 47 5,745.00 7,298.00 Hansen HMSV Motorised Valve 80 mm 80 mm 104 8,190.00 9,743.00 Hansen HMSV Motorised Valve 100 mm 100 mm 166 10,871.00 12,424.00

Hansen Motorised Valves - Model HMMRModel HMMR: Valve series with expansion plug is for high pressure drop applications such as liquid makeup and liquid injection. Can also be used in the same application as model HMMV valves where reduced capacities or larger line size connections are required. VPIF standard.

Less Strainer with Flanges Nominal Size

Flow Factor (CV)

Standard, System Price$ Excl. Gst

Power Close, System Price$ Excl. Gst

Hansen HMMR Motorised Valve 20 mm 20 mm 2.2 5,185.00 6,719.00 Hansen HMMR Motorised Valve 25 mm 25 mm 3.9 5,382.00 6,935.00 Hansen HMMR Motorised Valve 32 mm 32 mm 5.5 5,639.00 7,192.00 Hansen HMMR Motorised Valve 40 mm 40 mm 12 6,133.00 7,687.00 Hansen HMMR Motorised Valve 50 mm 50 mm 16 6,388.00 7,942.00 Hansen HMMR Motorised Valve 80 mm 80 mm 35 8,834.00 10,387.00 Hansen HMMR Motorised Valve 100 mm 100 mm 55 11,513.00 13,066.00

Hansen Motorised Valves - Model HMMVModel HMMV: Valve series is best suited for computer controlled operations using 4-20 mA signals. Ideal for precise temperature and pressure control, hot gas defrost, and other applications where accurate process control is required. VPIF standard.

Less Strainer with Flanges Nominal Size

Flow Factor (CV)

Standard, System Price$ Excl. Gst

Power Close, System Price$ Excl. Gst

Hansen HMMV Motorised Valve 20 mm 20 mm 6.4 5,185.00 6,719.00 Hansen HMMV Motorised Valve 25 mm 25 mm 11.7 5,382.00 6,935.00 Hansen HMMV Motorised Valve 32 mm 32 mm 16.4 5,639.00 7,192.00 Hansen HMMV Motorised Valve 40 mm 40 mm 35 6,133.00 7,687.00 Hansen HMMV Motorised Valve 50 mm 50 mm 47 6,388.00 7,942.00 Hansen HMMV Motorised Valve 80 mm 80 mm 104 8,834.00 10,387.00 Hansen HMMV Motorised Valve 100 mm 100 mm 166 11,513.00 13,066.00

Hansen Motorised Valves - Model HMXVModel HMXV: Valve series for precise liquid metering for direct expansion or liquid feed applications.

Less Strainer with Flanges Nominal Size

Flow Factor (CV)

Standard, System Price$ Excl. Gst

Power Close, System Price$ Excl. Gst

Hansen HMXV Motorised Valve 5 mm 5 mm 0.6 5,187.00 6,740.00 Hansen HMXV Motorised Valve 7 mm 7 mm 1.1 5,187.00 6,740.00

Hansen Motorised Valves - Motorised Valve AccessoriesModel System Price

$ Excl. Gst

HANSEN Valve Poistion Indicator 1,013.00 HANSEN VPIF Extension Cable 413.00 POWER Transformer 115/230/24V 328.00 POWERT Control I/Face HMSV 1,683.00 HANSEN Valve Opening Tool 488.00 HANSEN Calibration Key 28.00

IN186

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

2-STEP SOLENOID, SUCTION STOP & OIL CHANGE VALVES

Hansen HS4D - 2-Step Dual Solenoid ValvesRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

19737 19745 HS4D-20 2-Step Dual Solenoid Valve 3/4” SW 1,785.00 2,091.00

19738 19746 HS4D-25 2-Step Dual Solenoid Valve 1” SW 1,827.00 2,133.00

19739 19747 HS4D-32 2-Step Dual Solenoid Valve 11/4” SW 1,917.00 2,223.00

19740 19748 HS4D-40 2-Step Dual Solenoid Valve 11/2” SW 2,420.00 2,726.00

19741 19749 HS4D-50 2-Step Dual Solenoid Valve 2” SW 2,769.00 3,444.00

19742 19750 HS4D-65 2-Step Dual Solenoid Valve 2 1/1” SW 3,403.00 4,342.00

19743 19751 HS4D-80 2-Step Dual Solenoid Valve 3” SW 4,848.00 5,983.00

19744 19752 HS4D-100 2-Step Dual Solenoid Valve 4” SW 6,419.00 8,667.00

Hansen HCK5D - 2-Step Gas Powered Suction Stop ValvesRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

19753 19758 HCK5D-40 2-Step Suction Stop Valve 11/2” SW 2,167.00 2,620.00

19754 19759 HCK5D-50 2-Step Suction Stop Valve 2” SW 2,300.00 2,754.00

19755 19760 HCK5D-65 2-Step Suction Stop Valve 2 1/2” SW 2,825.00 3,278.00

19756 19761 HCK5D-80 2-Step Suction Stop Valve 3” SW 3,274.00 3,727.00

19757 19762 HCK5D-100 2-Step Suction Stop Valve 4” SW 4,907.00 5,361.00

Note: Hansen 2-Step Solenoid & Stop Valves Indent Only

Hansen Oil Drain ValvesRealcoldStock No.

Model Description System Price$ Excl. GST

17745 Hansen 50-2644 Apollo Oil Drain Valve 15 mm 301.00

17437 Hansen 50-2645 Apollo Oil Drain Valve 20 mm 372.00

IN187

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

Hansen HS4D - 2-Step Dual Solenoid ValvesRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

19737 19745 HS4D-20 2-Step Dual Solenoid Valve 3/4” SW 1,785.00 2,091.00

19738 19746 HS4D-25 2-Step Dual Solenoid Valve 1” SW 1,827.00 2,133.00

19739 19747 HS4D-32 2-Step Dual Solenoid Valve 11/4” SW 1,917.00 2,223.00

19740 19748 HS4D-40 2-Step Dual Solenoid Valve 11/2” SW 2,420.00 2,726.00

19741 19749 HS4D-50 2-Step Dual Solenoid Valve 2” SW 2,769.00 3,444.00

19742 19750 HS4D-65 2-Step Dual Solenoid Valve 2 1/1” SW 3,403.00 4,342.00

19743 19751 HS4D-80 2-Step Dual Solenoid Valve 3” SW 4,848.00 5,983.00

19744 19752 HS4D-100 2-Step Dual Solenoid Valve 4” SW 6,419.00 8,667.00

Hansen HCK5D - 2-Step Gas Powered Suction Stop ValvesRealcoldStock No.Without Strainer

RealcoldStock No.With Strainer

Description System Price$ Excl. GST

Without Strainer

System Price$ Excl. GST

With StrainerValve Flange Size

19753 19758 HCK5D-40 2-Step Suction Stop Valve 11/2” SW 2,167.00 2,620.00

19754 19759 HCK5D-50 2-Step Suction Stop Valve 2” SW 2,300.00 2,754.00

19755 19760 HCK5D-65 2-Step Suction Stop Valve 2 1/2” SW 2,825.00 3,278.00

19756 19761 HCK5D-80 2-Step Suction Stop Valve 3” SW 3,274.00 3,727.00

19757 19762 HCK5D-100 2-Step Suction Stop Valve 4” SW 4,907.00 5,361.00

Note: Hansen 2-Step Solenoid & Stop Valves Indent Only

AMMONIA & OTHER GAS SENSORS

Hansen Gas SensorsRealcoldStock No.

Model Description System Price$ Excl. GST

19526 HEC4-N100 Hansen HEC4-N100 Ammonia Sensor 2,332.00

19527 HEC4-N250 Hansen HEC4-N250 Ammonia Sensor 2,332.00

19528 HEC4-N1K Hansen HEC4-N1K Ammonia Sensor 2,332.00

19529 HSC4-N10K Hansen HSC4-N10K Semi-Conductor Ammonia Sensor 1,601.00

19657 HSC1-F3K-R22 Hansen HSC1-F3k Halogen R22 Basic Sensor 954.00

19658 HSC1-F3K-R507 Hansen HSC1-F3k Halogen R507 Basic Sensor 954.00

19659 HSC1-F3K-R134 Hansen HSC1-F3k Halogen R134a Basic Sensor 954.00

19660 HSC1-F3K-R404 Hansen HSC1-F3k Halogen R404 Basic Sensor 954.00

19661 HSC1-F3K-R410 Hansen HSC1-F3k Halogen R410 Basic Sensor 954.00

19663 HSC4H-F3K-R22 Hansen HSC4h-F3k Halogen R22 Harsh Sensor 1,808.00

19664 HSC4H-F3K-R507 Hansen HSC4h-F3k Halogen R507 Harsh Sensor 1,808.00

19665 HSC4H-F3K-R134 Hansen HSC4h-F3k Halogen R134a Harsh Sensor 1,808.00

19666 HSC4H-F3K-R404 Hansen HSC4h-F3k Halogen R404 Harsh Sensor 1,808.00

19667 HSC4H-F3K-R410 Hansen HSC4h-F3k Halogen R410 Harsh Sensor 1,808.00

19668 HSC4E-F3K-R22 Hansen HSC4E-F3K Halogen R22 Extreme Sensor 3,199.00

19669 HSC4E-F3K-R507 Hansen HSC4E-F3K Halogen R507 Extreme Sensor 3,199.00

19670 HSC4E-F3K-R134 Hansen HSC4E-F3K Halogen R134a Extreme Sensor 3,199.00

19671 HSC4E-F3K-R404 Hansen HSC4E-F3K Halogen R404 Extreme Sensor 3,199.00

19672 HSC4E-F3K-R410 Hansen HSC4E-F3K Halogen R410 Extreme Sensor 3,199.00

19673 HEC4H-N100 Hansen HEC4H-N100 Ammonia Harsh Sensor 3,168.00

19674 HEC4H-N1250 Hansen HEC4H-N250 Ammonia Harsh Sensor 3,168.00

19675 HEC4H-N1K Hansen HEC4H-N1K Ammonia Harsh Sensor 3,168.00

19676 HSC4H-N10K Hansen HEC4H-N10K Ammonia Harsh Sensor 2,291.00

19677 HEC4E-N100 Hansen HSC4E-N100 Ammonia Extreme Sensor 4,075.00

19678 HEC4E-N250 Hansen HEC4E-N250 Ammonia Extreme Sensor 4,075.00

19679 HEC4E-N1K Hansen HEC4E-N1K Ammonia Extreme Sensor 4,075.00

19680 HSC4E-N10K Hansen HSC4E-N1K Ammonia Extreme Sensor 3,199.00

19681 HIR1-C10K Hansen HIR1-C10K Carbon Dioxide Basic Sensor 1,675.00

19682 HIR4H-C10K Hansen HIR4H-C10K Carbon Dioxide Harsh Sensor 2,291.00

19683 HIR4E-C10K Hansen HIR4E-C10K Carbon Dioxide Extreme Sensor 3,199.00

19684 HVSC4-F5K Hansen HVSC4-F5k R22 Vent Sensor (Specify Refrigerant) 2,395.00

19685 HVSC4-N10K Hansen HVSC4-N10K Ammonia Vent Sensor 2,516.00

19686 GAS-100 Hansen Gas 100 Alert System 3,464.00

19687 GAS-250 Hansen Gas 250 Alert System 3,464.00

19688 GAS-1K Hansen Gas 1K Alert System 3,464.00

19689 GAS-10K Hansen Gas 10K Alert System 3,464.00

19690 31-1002 Hansen Sensor Element Shield 93.75

19691 31-1001 Hansen Sensor c/w DIN Quick Connect Plug 353.00

19692 31-1011 Hansen Portable Gas Detector 4,447.00

19693 31-1012 Hansen Sensor Module 0-50-500 PPM 1,407.00

19694 31-1013 Hansen Sensor Module 0-500-2000P:PM 1,811.00

19719 HLM6 Hansen 6-Channel Gas Monitor 2,366.00

Note: Leak detectors can be found on page CT136.

Basic

Explosion Proof

Gas Vent Line

Harsh Environment

IN188

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

REFRIGERANT PUMPS

Hermetic Pumpen Pump Range - Individual Bare PumpsRealcoldStock No.

Description Motor Size

15372 CAM 1/2 AGX 1.0

15373 CAM 1/3 AGX 1.0

15374 CAM 1/4 AGX 1.0

15375 CAM 1/5 AGX 1.0

15376 CAM 2/2 AGX 3.0

15377 CAM 2/2 AGX 4.5

15378 CAM 2/3 AGX 3.0

15379 CAM 2/3 AGX 4.5

15380 CAM 2/4 AGX 3.0

15381 CAM 2/4 AGX 4.5

15382 CAM 2/5 AGX 3.0

15383 CAM 2/5 AGX 4.5

15384 CAM 2/5 AGX 6.5

15385 CAM 2/6 AGX 3.0

15386 CAM 2/6 AGX 4.5

15387 CAM 2/6 AGX 6.5

15388 CAMR 2/2 AGX 3.0

15389 CAMR 2/2 AGX 4.5

15390 CAMR 2/3 AGX 3.0

15391 CAMR 2/3 AGX 4.5

15392 CAMR 2/4 AGX 3.0

15393 CAMR 2/4 AGX 4.5

15394 CAMR 2/5 AGX 3.0

15395 CAMR 2/5 AGX 4.5

15396 CAMR 2/5 AGX 6.5

15397 CAMR 2/6 AGX 3.0

15398 CAMR 2/6 AGX 4.5

15399 CAMR 2/6 AGX 6.5

15400 CAM 3/2 AGX 8.5

15401 CAM 3/2 CKPX 12.0

15402 CAM 3/2 CKPX 64 R-2

15403 CAM 3/3 CKPX 8.5

15404 CAM 3/3 CKPX 12.0

15405 CAM 3/3 CKPX 64 R-2

15406 CAM 3/4 CKPX 12.0

15407 CAM 3/4 CKPX 64 R-2

15408 CNF 40-160 AGX 3.0

15409 CNF 40-160 AGX 4.5

15410 CNF 40-160 AGX 6.5

15411 CNF 40-160 AGX 8.5

15412 CNF 40-200 AGX 4.5

15413 CNF 40-200 AGX 6.5

15414 CNF 40-200 AGX 8.5

15415 CNF 40-200 CKPX 12.0

15416 CNF 50-160 AGX 4.5

15417 CNF 50-160 AGX 6.5

15418 CNF 50-160 AGX 8.5

15419 CNF 50-160 CKPX 12.0

15420 CNF 50-200 AGX 6.5

15421 CNF 50-200 AGX 8.5

15422 CNF 50-200 CKPX 12.0

CAM 2/3

CAMR 2/3

CNF 40-160

IN189

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

REFRIGERANT PUMP ACCESSORIES

Hermetic Pumpen - Pump AccessoriesRealcoldStock No.

Description System Price$ Excl. Gst

15423 Hermetic Qmin Orifice Dn20 26.80

15424 Hermetic Qmin Orifice Dn25 26.80

15425 Hermetic Qmin Orifice Dn32 26.80

15426 Hermetic Qmax Orifice Dn32 26.80

15427 Hermetic Qmax Orifice Dn40 229.00

15428 Hermetic Qmax Orifice Dn50 260.00

15429 Hermetic CAM1 Pump Flange Set 159.00

15430 Hermetic CAM2 Pump Flange Set 198.00

17008 Hermetic CAMR 2 Pump Flange Set 225.00

15431 Hermetic CAM3 Pump Flange Set 233.00

15432 Hermetic CNF50 Pump Flange Set 264.00

15433 Hermetic Dn20 M/F Flange Set 150.00

15434 Hermetic Dn25 M/F Flange Set 159.00

15435 Hermetic Dn32 M/F Flange Set 185.00

15436 Hermetic Dn40 M/F Flange Set 220.00

15437 Hermetic Dn50 M/F Flange Set 247.00

15438 Hermetic AGX1/3/4.5 Base Plate 514.00

15439 Hermetic AGX 8.5 Base Plate 1,289.00

15440 Hermetic Ckpx 12.0 Base Plate 1,640.00

15441 Hermetic Ckpx 64r-2 Base Plate 2,089.00

15442 Hermetic Ql-61-44-8 Flow Regulator 774.00

15443 Hermetic Ql-62-85-8 Flow Regulator 1,750.00

15444 Hermetic Ql-62-110-8 Flow Regulator 1,750.00

15445 Hermetic Ql-61-150-8 Flow Regulator 1,750.00

15446 Hermetic Ql-62-85-8 Flow Regulator 1,750.00

15447 Hermetic Ql-62-110-8 Flow Regulator 1,750.00

15448 Hermetic Ql-61-150-8 Flow Regulator 1,750.00

15449 Hermetic Inducer 1,597.00

15450 Hermetic Thermistor Kl 170 594.00

15452 Hermetic Nitrogen Filling 782.00

15453 Hermetic Marine Cable 717.00

15454 Hermetic Small Pump Packing 136.00

15455 Hermetic Large Pump Packing 220.00

Notes on Ordering Hermetic Pumps & Accessories

• Costs of freight of Accessories are included in the cost of freight of the bare pump. Where accessories are ordered without pumps, we will calculate freight and other costs of delivery and add to the cost of the accessory.

• Small Pump Packing is chargeable on all base CAM 1 and 2 pumps.

• Large Pump Packing is chargeable on all CAM3 and CNF type Pumps.

• For Carbon Dioxide Pumps, you need to add the cost of Pressure Testing to 45 bar. Pumps for other refrigerants are available on request.

IN190

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

REFRIGERANT PUMP ACCESSORIES

Hermetic Pumpen - Pump AccessoriesRealcoldStock No.

Description System Price$ Excl. Gst

17711 Pump Gasket Set for CAM 2/4 142.00

17712 Pump Gasket Set for CAM 3/3 46.35

17714 Pump Gasket Set for CNF50-200 30.90

17715 Pump Gasket Set for CNF50-160 27.85

17716 Pump Gasket Set for CAM 1/4 36.60

17717 Motor Gasket Set for for AGX4.5 114.00

17718 Motor Gasket Set for for AGX8.5 25.25

17720 Motor Gasket Set for for AGX6.5 114.00

19570 Motor Gasket Set for AGX3.0 92.70

60071 Bearing Set AGx3.0 1,922.00

60072 Bearing Set AGx4.5 1,922.00

60073 Bearing Set AGx6.5 1,922.00

60074 Bearing Set AGx8.5 2,447.00

60075 Bearing Set CKPx12.0 2,902.00

14003 Stator Lining and Sealing Disc AGx3.0 474.00

W9322 Stator Lining and Sealing Disc AGx4.5/6.5 403.00

60076 Stator Lining and Sealing Disc AGx8.5 574.00

60077 Stator Lining and Sealing Disc CKPx12.0 789.00

IN191

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

VALVES - SOLENOID COILS

Hansen Solenoid CoilsRealcoldStock No.

Model Description System Price$ Excl. Gst

18061 70-1092 Hansen Solenoid Replacement Coil 115V 116.00

18062 70-1093 Hansen Solenoid Replacement Coil 230V 116.00

18063 70-1094 Hansen Solenoid Replacement Coil 24V AC 116.00

18064 70-1095 Hansen Solenoid Replacement Coil 24V DC 116.00

18068 70-0584 Hansen Solenoid Replacement Coil 115V 69.05

18069 70-0585 Hansen Solenoid Replacement Coil 230V 69.05

18070 70-0586 Hansen Solenoid Replacement Coil 24V AC 69.05

18071 70-0583 Hansen Solenoid Replacement Coil 24V DC 69.05

18065 70-1100 Hansen Beacon Pilot Light Kit Red 89.65

18066 70-1102 Hansen Beacon Pilot Light Kit Green 89.65

18067 70-1101 Hansen Beacon Pilot Light Kit Amber 89.65

Hansen Danvalve Solenoid Adaptor KitRealcoldStock No.

Model Description System Price$ Excl. Gst

19534 70-1104 Hansen to Danfoss Coil Conversion Kit

(Includes “O” Ring, Circlip and Fixing Cap)

31.95

Parker Ammonia Solenoid CoilsRealcoldStock No.

Model Description System Price$ Excl. Gst

19309 205226 Refspec Encapsulated Sol Coil 230V 50HZ 246.00

19311 207868 Refspec / Sporlan KSMA32 Sol Coil 230V 50HZ 239.00

19418 207608 Sporlan MKC3 Sol Coil 230V 50HZ 237.00

17307 205213 Refspec Encapsulated Sol Coil 24V DC 249.00

60056 311515 Sporlan MKC-2 Sol Coil 208-240V 50-60Hz 67.00

Hansen Solenoid Coils

• Hansen coils are Watertight Encapsulated Solenoid coils with no outside frame. All coils are normally

sold complete with DIN Plug Socket and come with “O” Ring and Knob. Normal Voltage available is

230V, however, 115V, 24V AC, 24V DC are also normally available ex-stock.

• Replacement Coils which do not include a Knob and Din Plug are also available in 300 mm Tailed

and Conduit style connections on request.

• Beacon Pilot Light Kits, to indicate when solenoids are operating are available on request. This kit

includes Beacon Pilot Knob and “O” Ring.

IN192

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

VALVES - SPARES

Valves - SparesRealcoldStock No.

Model Vendor Part No. Description System Price$ Excl. Gst

12869 LLSWE HLLSWE Switch Assembly, replacement, DIN plug included 656.00

17395 HS6, HS8 70-0065 Flange Gasket Suits Flange #50 15.45

17396 AR25-32 HS7 70-0132 Flange Gasket Suits Flange #100 15.45

17397 AR40-50 75-0138 Flange Gasket Suits Flange #200 15.45

17398 AR65 75-0125 Flange Gasket Suits Flange #250 15.45

17399 AR80 75-0137 Flange Gasket Suits Flange #300 21.65

17400 AR100 75-0253 Flange Gasket Suits Flange #400 35.05

17404 All Sol Valves 70-1052 Hansen MS Pilot Solenoid 195.00

17519 AR32 65-1023 V-Port Seat Kit 397.00

17520 AR40 75-1029 V-Port Seat Kit 417.00

17521 AR50 75-1030 V-Port Seat Kit 542.00

17522 AR100 75-1033 V-Port Seat Kit 715.00

17524 HCK2 75-1004 Piston Seat Kit 448.00

17525 AR100 75-1028 Piston Kit 940.00

17617 ST050 78-1001 Strainer Screen Kit 85.50

17618 ST100 78-1003 Strainer Screen Kit 177.00

18938 ST100 78-1013 Strainer Screen Kit Heavy Duty 236.00

18939 ST100 78-1014 Strainer Screen Kit Fine 100 Mesh 201.00

17619 ST200 78-1005 Strainer Screen Kit 250.00

17620 ST250 78-1007 Strainer Screen Kit 271.00

17622 ST050 78-0016 Strainer Cover Gasket 15.45

17623 ST100 78-0026 Strainer Cover Gasket 15.45

17624 ST200 75-0113 Strainer Cover Gasket 21.65

17625 ST250 75-0128 Strainer Cover Gasket 21.65

18940 ST100 78-1015 Strainer System Start Up Bag 82.40

18941 ST200 78-1016 Strainer System Start Up Bag 91.70

18942 ST250/300 78-1017 Strainer System Start Up Bag 111.00

18943 ST400 78-1018 Strainer System Start Up Bag 118.00

17627 HS6 70-1011 Gasket Kit 69.05

17628 HS8 70-1005 Gasket Kit 78.30

17629 HS7 70-1017 Gasket Kit 91.70

17632 HS8A 70-1001 Bonnet-Cartridge Kit 410.00

17633 HS7 70-1018 Bonnet-Cartridge Kit 542.00

19943 HS 70-0301 Hansen Solenoid Tube Gasket 6.20

17636 HS8 70-1002 Piston Assembly Kit 209.00

17637 HS7 - 3/4" 70-1019 Piston Assembly Kit 505.00

17638 HS7-25 70-1020 Piston Assembly Kit 505.00

17639 HS7-32 70-1021 Piston Assembly Kit 574.00

17642 HS6, HS7, HS8 70-1059 Solenoid Tube/Plunger Kit 227.00

17643 HS7 70-1022 Stem Kit 94.80

For more information on industrial products please call +64 (0)9 526 5955.

IN193

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Indu

stria

l

VALVES - SPARES

Valves - SparesRealcoldStock No.

Model Vendor Part No. Description System Price$ Excl. Gst

17647 AR20-32 75-1023 Gasket Kit 65.95

17648 AR40-50 75-1039 Gasket Kit 78.30

17649 AR65 75-1040 Gasket Kit 91.70

17650 AR80 75-1041 Gasket Kit 111.00

17651 AR100 75-1042 Gasket Kit 123.00

17654 AR20-32 75-1019 Piston Kit 325.00

17655 AR40-50 75-1025 Piston Kit 539.00

17656 AR65 75-1026 Piston Kit 684.00

17657 AR80 75-1027 Piston Kit 823.00

17660 AR20 75-1020 V-Port Seat Kit 274.00

17661 AR25 75-1021 V-Port/Seat Kit 369.00

17665 AR65 75-1031 V-Port Seat Kit 602.00

17666 AR80 75-1032 V-Port/Seat Kit 656.00

17670 AR Port 75-1071 Gasket Kit 15.45

17671 M30 M3,M3K 75-1108 Diaphragm/Gasket Kit 75.20

17699 Henry n/a Flange Gasket Suits 1 1/4 in Flange 7.25

19116 VLT 77-1004 VLT Digital Readout Kit 1,330.00

19127 HMMR 75-1154 V-Port Kit For HMMR 32 861.00

19128 HMMR 75-1148 Gasket Kit 20-32 mm HMMR 24.75

19129 HMMR 75-1150 Gasket Kit 40-50 mm HMMR 28.85

19130 HMMR 75-1151 Gasket Kit 80 mm HMMR 259.00

19131 HMMR 75-1167 Cartge Kit 20-32 mm HMMR 1,847.00

19132 HMMR 75-1168 Cartge Kit 40-50 mm HMMR 2,033.00

19133 HMMR 75-1171 Power Head for Kit Pwr SMV 5,670.00

19134 HMMR 75-1183 Pwr-Close Kit Pwr Head 7,869.00

19135 HMMR 75-1169 Cartridge Kit 80 mm HMMR 1,942.00

19136 HMMR 75-2922 Can Kit HMMR 533.00

19137 HMMR MOVT Manual Vlv Opening Tool 691.00

19138 HMMR 75-1185 Calibration Key HMMR 38.15

19139 HMMR 75-1149 Pilot Seat Kit 80 mm HMMR 262.00

19140 HMMR 75-1153 Pilot Seat Kit 100 mm HMMR 262.00

19141 HGV 50-1070 Gasket Kit 8 mm HGV 24.75

19142 H7773/4 50-1074 Gasket Kit 10 mm H7773/4 44.30

19143 Stop/H/Exp 50-1040 Gasket Kit 13-32 mm Vlv 53.60

19144 Stop/H/Exp 50-1023 Gasket Kit 40-50 mm Vlv 72.10

19145 Stop 50-1043 Gasket Kit 65-80 mm Vlv 75.20

19146 Stop 50-1065 Gasket Kit 100 mm Vlv 111.00

19147 Stop 50-1082 Gasket Kit 125 mm Vlv 132.00

19148 Stop 50-1083 Gasket Kit 150 mm Vlv 143.00

19533 Stop 50-1084 Gasket Kit 200 mm Ra Vlv 220.00

19308 HA2BK 75-1107 HA2BK Overhaul Kit 93.75

19935 Consumable - Phenol Pthalate Ammonia Test Paper 45.00

For more information on industrial products please call +64 (0)9 526 5955.

Refrigera

tion

Capital P

lant

Cap

ital P

lant

Capital PlantL’unite Sealed CP196

Drawings CP197R404a Medium Temperature CP198R134a Medium Temperature CP198R404a Low Temperature CP198

Easypack Sealed Condensing Units CP199R404a Medium Temp CP200R404a Low Temp CP200

Realpack Packaged Refrigeration Condensing Units CP201R404a Medium Temperature CP201R404a Low Temperature CP201

Realcold Milk Vat Air Cooled Condensing Units CP202On Farm Refrigeration CP202Water Heating Options CP202

Copeland Scroll Condensing Units CP203R404a Medium Temperature CP203R404a Low Temperature CP203

Realcold Custom Build Semi-Sealed Units CP204R404a Medium Temperature CP205R404a Low Temperature CP205

Realcold Semi-Sealed Compressor Receiver Packages CP206R404a Medium / Low Temp CP206

Realcold Semi-Sealed, Copeland Scroll Unit Accessories CP207Liquid Line Assembly - Medium & Low Temp Models CP207Oil Separator Assembly CP207Oil Return Line Sightglass CP207Suction Line Assembly CP207Suction Line Refillable Filter Assembly CP208Suction Line Filter Fitted Assembly CP208Pressure Controls CP208Capacity Controls CP208Miscellaneous CP208

Realcold Air Cooled Condensers CP209Vertical Discharge CP209Horizontal Discharge CP210Hanwest Water Cooled Marine Condenser CP210

Realcold Evaporator Units CP211HCT Series - Medium Temp - No Defrost CP212HCT Series - Low Temp - Full Electric Defrost CP212Rondo Series - Medium Temp - No Defrost CP212TM Dual Discharge - Medium Temp - Air Defrost CP212N Series Medium Temp - Air Defrost CP213N Series - Low Temp - Full Electric Defrost CP213S Series - Medium Temp - Air Defrost CP214S Series - Medium Temp - Partial Defrost CP214S Series - Low Temp - Full Electric Defrost CP214R Series - Medium Temp - Air Defrost CP215V Series - Medium Temp - Air Defrost CP215R Series - Low Temp - Electric Defrost CP215V Series - Low Temp - Electric Defrost CP215

Hc Evaporator Range CP216Realcold Medium Temperature Evaporators CP216Realcold Low Temperature Evaporators CP217

Ice Machines CP218

Chilled Water Packages CP222

Compressor And Condensing Unit Warranty CP223

CP196

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

L’Unite Hermetique is a brand name of Tecumseh Europe, recognised as a leader in commercial refrigeration compressor manufac-ture. For more than 50 years, Tecumseh has been developing and manufacturing compressors, condensing units and fan motors. Reliability, performance, silent operation, easy installation and ergonomics are the driving force behind the company, with an overall focus on differentiation and development of customer loyalty.

L’Unite has a proud tradition and a strong future, and the condensing unit range to suit a wide variety of applications.

L’Unite Sealed condensing units feature:

• ULapprovedreceivers

• FanGuard

• Pre-Wiredcompressorandfanmotor

• Suctionlineisolatingvalve

• Liquidlineisolatingvalves

• FH/TFHmodelsaresuppliedcompletewithDPcontrol/CCheater, oil level sight glass fitted CAJ4517, CAJ4519 complete with DP control

• 12monthmanufacturerswarranty

• ManufacturedbyTecumseh Europe

L’UNITE SEALED

CP197

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

DRAWINGS OF L’UNITE SEALED CONDENSING UNITS

FH Series CAJ Series

CAE Series AEZ Series

Drawings

CP198

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

L´UNITE SEALED CONDENSING UNITS

R404a Medium TemperatureRealcoldStock No.

Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST

-10 -5 0 7.5 10 L W H

220/240 Volt 50 Hz Single Phase

C9407^ AEZ4425ZHR ‘1/5 4.5 316 386 458 565 608 417 317 224 508.73

C9408^ AEZ4430ZHR ‘1/4 5.7 445 534 628 773 833 389 330 257 498.37

C9412^ AEZ4440ZHR ‘1/3 7.55 600 712 831 1012 1085 490 350 292 537.91

C9426^ CAE4450ZHR ‘3/7 9.4 738 881 1034 1274 1374 490 350 292 644.58

C9430^ CAE9460Z MHR ‘1/2 11.3 880 1035 1195 1435 1532 490 356 292 719.15

C9432^ CAE9470Z MHR ‘1/2 13.3 1123 1322 1532 1852 1984 490 430 338 771.36

C9442^ CAJ9480Z MHR ‘5/8 15.2 1317 1562 1825 2231 2397 480 430 338 994.03

C9444^ CAJ9510Z MHR ‘1 18.3 1599 1888 2196 2671 2876 486 430 338 1,067.87

C9446^ CAJ9513Z MHR ‘1 1/8 24.2 1858 2176 2488 2913 3068 486 430 338 1,148.91

C9448 CAJ4517Z HR ‘1 1/4 25.95 2354 2792 3225 3842 4079 620 510 450 1,472.56

C9450 CAJ4519Z HR ‘1 1/2 34.45 2924 3452 3999 4812 5136 620 510 450 1,553.67

C9470 FH4524ZHR ‘2 43.5 3180 3768 4400 5342 5722 620 510 450 1,784.48

C9473 FHS4531Z HR ‘2 1/2 56.65 4381 5169 5962 7111 7561 608 628 558 2,187.74

R134a Medium TemperatureRealcoldStock No.

Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST

-10 -5 0 7.5 10 L W H

220/240 Volt 50 Hz Single Phase

C9126^ AEZ4425Y HR ‘1/5 7.55 334 418 507 644 700 417 314 224 547.74

C9130^ AEZ4430Y HR ‘1/4 8.85 416 516 625 796 867 389 330 257 547.62

C9142^ CAE4440Y HR ‘1/3 12.05 546 667 797 997 1079 389 330 257 576.01

C9150^ CAE4448Y HR ‘3/8 14.15 657 810 971 1217 1318 490 350 292 695.41

C9152^ CAE4456Y HR ‘3/7 16 721 888 1069 1353 1470 490 350 292 689.23

C9156^ CAJ4461Y HR ‘1/2 18.3 767 933 1110 1380 1487 485 356 305 831.74

C9160^ CAJ4492Y HR ‘3/4 25.95 1254 1552 1878 2390 2600 486 430 338 1,010.76

C9162^ CAJ4511Y HR ‘1 32.7 1576 1917 2279 2826 3043 486 430 338 1,115.91

C9170 FH4518Y HR ‘1 1/2 53.2 2425 3026 3690 4760 5214 620 510 450 1,605.28

C9173 FH4525Y HR ‘2 74.25 2925 3629 4389 5581 6076 630 510 450 1,690.98

R404a Low TemperatureRealcoldStock No.

Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST

-30 -25 -20 -15 -10 L W H

220/240 Volt 50 Hz Single Phase

C9406^ AEZ2415Z BR ‘3/8 8.1 267 337 407 484 567 417 314 224 429.68

C9418^ CAE2417Z BR ‘1/2 11.3 321 408 495 587 682 495 338 243 538.35

C9420^ CAE2420Z BR ‘1/2 12.54 394 499 605 716 832 389 330 257 623.19

C9422^ CAE2424Z BR ‘5/8 15 518 645 772 910 1057 510 356 292 622.20

C9436^ CAJ2432Z BR ‘3/4 18.3 594 729 864 1022 1195 485 342 299 713.19

C9438^ CAJ2446Z BR ‘1 26.18 937 970 1416 1690 1989 486 430 338 1,002.50

C9440^ CAJ2464Z BR ‘1 1/2 35.45 1172 1463 1755 2067 2382 486 430 338 1,119.98

C9462 FH2480Z BR ‘2 53.2 1641 2030 2519 2980 3417 620 510 450 1,533.89

• ^ Note that these units do not include a pressure switch.

• All ratings are based on an ambient of +30°C , 10K Superheat, 2K Sub-Cooling.

• Refer to warranty section of catalogue for warranty details.

CP199

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

EASYPACK SEALED CONDENSING UNITS

EasyPack - Realcold Condensing Units Feature:

• All units fitted with dual pressure controls

• Compressor / fan motor wired (Single Phase Units Only)

• Liquid line isolating valves

• Suction isolating valves

• FH & TFH models are complete with crankcase heaters, oil sight glasses

• Unit warranty as per page CP225

Custom Design & Build Service

Realcold offer a full range of custom designed units based upon the L’Unite Sealed and the Frascold Semi/Screw range of Compressors.

These units can be manufactured to suit your individual requirements encompassing all of the common refrigerants from R134a through to C02. Please contact your local Realcold branch for further information.

CP200

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

EASYPACK CONDENSING UNITS

R404a Medium TempRealcoldStock No.

Compressor H/P Capacity (w) Ambient 32 Suction (mm)

Liquid (mm)

Wgt (Kg)

Sound Power (dBA)

Dimensions (mm) System Price Excl. GST

-10 -5 0 5 10 L W H

220/240 Volt 50Hz Single Phase

C0757E CAJ 9513 Z 1 1/8 2108 2405 2807 3220 3635 15.9 9.5 47 76 550 650 465 1,450.00

C0758E CAJ 4517 Z 1 1/4 2272 2845 3168 3634 4100 15.9 9.5 60 77 600 600 560 1,525.00

C0759E CAJ 4519 Z 1 1/2 2526 3638 4241 4864 5499 15.9 9.5 60 79 600 600 560 1,795.00

C0762E FH 4524 Z 2 3586 4291 5023 5786 6587 15.9 9.5 73 79 600 600 560 2,532.00

C0764E FH 4531 Z 2 1/2 4855 5850 6764 7754 8767 22.2 9.5 76 79 600 600 560 2,839.00

R404a Medium TempRealcoldStock No.

Compressor H/P Capacity (w) Ambient 32 Suction (mm)

Liquid (mm)

Wgt (Kg)

Sound Power (dBA)

Dimensions (mm) System Price Excl. GST

-10 -5 0 5 10 L W H

400 Volt 50Hz Three Phase

C0964E TFH 4540 Z 3 5628 6740 7908 9149 10481 22.2 12.7 80 82 600 600 560 2,839.00

C0968E TAG 4553 Z 4 1/2 7332 8948 10685 12509 14387 22.2 12.7 118 84 1080 680 565 3,350.00

C0971E TAG 4561 Z 5 7567 9713 11323 13365 15382 28.6 12.7 118 84 1080 680 565 3,680.00

C0973E TAG 4573 Z 6 1/4 10023 12034 14168 16426 18808 28.6 12.7 135 84 1080 680 565 3,980.00

C0977E 2 x TAGP 4553 Z 9 13946 17104 20605 24207 27667 28.6 15.9 213 87 1420 730 870 5,500.00

C0980E 2 x TAGP 4561 Z 10 16904 20225 23683 27278 31010 28.6 15.9 218 87 1420 730 870 6,250.00

C0985E 2 x TAGP 4573 Z 12 22356 25974 30077 34665 39738 28.6 15.9 218 87 1420 730 870 6,875.00

R404a Low TempRealcoldStock No.

Compressor H/P Capacity (w) Ambient 32 Suction (mm)

Liquid (mm)

Wgt (Kg)

Sound Power (dBA)

Dimensions (mm) System Price Excl. GST

-30 -25 -20 -15 -10 L W H

220/240 Volt 50Hz Single Phase

C0787E CAJ 2464 Z 1 1/2 1184 1495 1840 2212 2608 15.9 9.5 40 76 550 650 395 1,484.00

C0789E FH 2480 Z 2 1800 2271 2746 3225 3709 15.9 9.5 73 79 600 600 560 2,165.00

R404a Low TempRealcoldStock No.

Compressor H/P Capacity (w) Ambient 32 Suction (mm)

Liquid (mm)

Wgt (Kg)

Sound Power (dBA)

Dimensions (mm) System Price Excl. GST

-30 -25 -20 -15 -10 L W H

400 Volt 50Hz Three Phase

C0793E TFH 2511 Z 3 2356 3030 3767 4566 5427 15.9 9.5 80 82 600 600 560 2,567.00

C0794E TAG 2516 Z 4 3268 4188 5188 6269 7430 22.2 9.5 107 81 1080 680 565 3,064.00

C0795E TAG 2522 Z 5 4202 5401 6674 8019 9438 22.2 9.5 107 81 1080 680 565 4,220.00

C0796E 2 x TFHP 2511 Z 6 4633 5921 7296 8619 10006 28.6 9.5 156 81 1080 800 570 6,750.00

CO797E 2 x TAGP 2516 Z 8 6508 8417 10540 12878 15430 22.2 15.9 210 82 1420 730 870 7,250.00

C0798E 2 x TAGP 2522 Z 10 7713 9850 12220 14822 17658 28.6 15.9 215 83 1420 730 870 8,750.00

Note: All of the EasyPack Units are available for operation on R134a. Please contact the Technical Department with your requirements.

CP201

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALPACK PACKAGED REFRIGERATION CONDENSING UNITS

RealPack Features:

• TecumsehL’UniteHermetiquecompressors

• DesignedforR404aandR507refrigerants

• Suitableforambienttemperaturesupto46°C-lowoperatingcost

• Condenserfancontrolforstableoperation

• Condensercoilprotection

• OilSeparatoronallmodels

• Liquiddrierandsightglassonallmodels

• SuctionAccumulatoronlowtemperaturemodels

• Easyaccesstoallserviceablecomponents

• Easyandcosteffectiveinstallation-fullywired&robustpowdercoatedenclosure

R404a Medium TemperatureRealcoldStock No.

Compressor Nom. HP

Capacity (w) Ambient 32 Suction connect.

Liquid connect.

Dimensions (mm) System Price$ Excl. Gst

-10 -5 0 5 10 L W H

240 Volt 50Hz Single Phase

C9513 CAJ4517Z 1 1/4 2269 2863 3559 4356 5256 5/8 3/8 1070 480 750 3,055.92

C9515 CAJ4519Z 1 1/2 2992 3783 4686 5702 6829 5/8 3/8 1070 480 750 3,402.72

C9520 FH4524Z 2 3516 4460 5546 6773 8143 5/8 3/8 1070 480 750 3,645.48

415 Volt 50Hz Three Phase

C9525 TFH4531Z 2 1/2 4566 5813 7225 8805 10551 5/8 3/8 1285 625 820 4,256.46

C9530 TFH4540Z 3 6155 7571 9235 11147 13307 5/8 3/8 1285 625 820 4,843.98

C9545 TAG4553Z 4 1/2 6764 8855 11372 14317 17690 7/8 1/2 1285 625 820 5,142.84

C9550 TAG4561Z 5 8163 10446 13234 16526 20326 7/8 1/2 1285 625 820 5,555.94

C9561 TAG4573Z 6 1/4 10633 13346 16638 20511 24966 7/8 1/2 1285 625 820 5,703.84

C9575 2xTAGP4546Z 7 1/2 11716 15690 20244 25380 31100 1 1/8 5/8 1660 790 1015 8,800.00

C9590 2xTAGP4561Z 10 16326 20892 26468 33052 40652 1 1/8 5/8 1660 790 1015 9,850.00

C9596 2xTAGP4573Z 12 1/2 21266 26692 33276 41022 49932 1 1/8 5/8 1660 790 1015 10,500.00

R404a Low TemperatureRealcoldStock No.

Compressor Nom. HP

Capacity (w) Ambient 32 Suction connect.

Liquid connect.

Dimensions (mm) System Price$ Excl. Gst

-30 -25 -20 -15 -10 L W H

220/240 Volt 50Hz Single Phase

C9522 FH2480Z 2 1741 2296 2852 3518 4209 5/8 3/8 1070 480 750 3,876.00

400 Volt 50Hz Three Phase

C9532 TFH2511Z 3 2503 3206 3910 4743 5617 5/8 3/8 1285 625 820 4,396.20

C9542 TAG2516Z 4 3406 4498 5590 6865 8212 7/8 1/2 1285 625 820 5,056.14

C9552 TAG2522Z 5 4455 5746 7037 8563 10179 7/8 1/2 1285 625 820 5,279.52

C9580 2xTAGP2516Z 8 6750 8874 10999 13503 16118 1 1/8 5/8 1660 790 1015 9,450.00

C9593 2xTAGP2522Z 10 9144 11693 14243 17657 21182 1 1/8 5/8 1660 790 1015 9,890.00

• Note that all capacities are rated at 30°C ambient, 10K superheat, 2K sub-cooling.

• For complete technical data, refer to Appendix TD227.

CP202

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD MILK VAT AIR COOLED CONDENSING UNITS

Realcold Milk Vat Units (RMV)

Next Generation for On-farm Refrigeration. Purpose built with the milk shed environment and servicing in mind.

Ease of service: Simple in its design. No unnecessary complicated electronics. Components available from a wide range of suppliers.

Proven reliability: Retains use of reciprocating technology in an innovative way. No compromising system efficiency.

Availability: Units held in stock.

Affordable: Competitively priced.

Superior Efficiency: Multiplexed compressors enable the most efficient use of energy.

Ease of adaptability: Adaptable to a wide range of applications, from a single platform:

• Saturation temperatures from +20°C to -35°C

• Condensing temperatures up to +55°C

• Capacities from 2 kW to 40 kW

On Farm RefrigerationRealcoldStock No.

Model Compressor Nom. HP Cooling Capacity kW

Dimensions (mm) Weight (Dry) Kg System Price$ Excl. Gst

L D H

380 - 415V 50Hz Three Phase

C6720 RMV 450 TAG 4553Z 4.5 11.4 1080 680 565 118 POA

C6721 RMV 600 TAG 4573Z 6.0 15.1 1080 680 565 135 POA

C6722 RMV 900 TAG 4553Z 9.0 22.0 1420 730 870 213 POA

C6723 RMV 1000 TAG 4561Z 10.0 25.1 1420 730 870 218 POA

C6724 RMV 1200 TAG 4573Z 12.0 31.9 1420 730 870 218 POA

C6725 RMV 1500 TAG 4561Z 15.0 36.3 1900 1120 870 300 POA

Water Heating OptionsRealcoldStock No. NormalDesuperheaters

RealcoldStock No.Full SizeDesuperheaters

Model Hot Water Heating Capacity kW* System Price$ Excl. GST

Normal / Full SizeDesuperheaters

OHC15-20 OMC60-20 RMV 450 5 POA

OHC15-20 OMC60-20 RMV 600 8.3 POA

OHC15-20 OMC60-30 RMV 900 11 POA

OHC15-20 OMC60-30 RMV 1000 12.4 POA

OHC15-30 OMC60-30 RMV 1200 15.2 POA

OHC15-30 OMC60-40 RMV 1500 18.2 POA

Features include:

• Single, Twin or Triple multiplexed compressors offering staged capacity control over a wide range of applications.

• 6 sizes, covering capacities from 11 to 36 kW.

• ASERCOM compressor certification, assuring independent verification of published performance capacity figures.

• Horizontial air flow. Performance rated at up to 55 degrees condensing temperature.

Specifications:

• Compressor: Each high efficiency hermetic type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration.

• Cooling Capacity: Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404a refrigerant.

• Refrigeration Piping: The standard unit allows for a line length of up to 30m.

• Wiring: Electrical supply required (including voltage fluctuation limits). 3 phase 342-436 V a.c. 50 Hz with neutral and earth. A control panel located in the outdoor unit is fully wired, ready to accept the main power supply.

• Safety Features: HP / LP switch and an anti rapid cycle timer for compressor protection. The compressor also has internal overload protection. Circuit breaker control circuits.

CP203

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

COPELAND SCROLL CONDENSING UNITS

Custom Design & Build Service

Copeland Scroll Condensing Units, both sealed and semi, are designed and manufactured in New Zealand, using Copeland Compressors. All units can be manufactured to suit your individual requirements. Refer to the following accessory pages for options and pricing. (Note: Condensing units must be selected on rated capacity NOT nominal HP rating).

Copeland Scroll Condensing Units include:

• UnitsfittedwithCopelandZBrefrigerationratedscrollcompressors (not ZR air con rated models)

• Allunitsfittedwithdualpressurecontrols

• Receiveroutletvalve

• CompressorRotolockvalves

• Oilandsightglass

• UnitwarrantyasperpageCP223

R404a Medium TemperatureRealcoldStock No.

Model Compressor Nom. HP M³ / HR Disp.

R404a Capacity in Watts @ -5°C SST

Condenser Dimensions (mm) System Price$ Excl. Gst

L D H

380/415 Volt 50Hz Three Phase

CUS 0223 CMTZ 400 ZB30KQE-TFD 4.0 11.8 8530 SCS2150 1052 914 519 POA

CUS 0225 CMTZ 500 ZB38KQE-TFD 5.0 14.5 10430 SCT2170 1269 914 723 POA

CUS 0228 CMTZ 600 ZB45KQE-TFD 6.0 17.2 12460 SCT2215 1269 914 723 POA

CUS 0230 CMTZ 750 ZB58KQE-TFD 7.5 20.9 13850 SCT2215 1269 914 723 POA

CUS 0233 CMTZ 1000 ZB76KQE-TFD 10.0 28.9 19860 SCR2275 1484 1034 775 POA

CUS 0235 CMTZ 1300 ZB92KCE-TWD 13.0 35.6 25290 SCR2385 1484 1034 928 POA

CUS 0238 CMTZ 1500 ZB11MCE-TWD 15.0 42.1 30960 SCR2475 1484 1034 1028 POA

R404a Low TemperatureRealcoldStock No.

Model Compressor Nom. HP M³ / HR Disp.

R404a Capacity in Watts @ -25°C SST

Condenser Dimensions (mm) System Price$ Excl. Gst

L D H

380/415 Volt 50Hz Three Phase

CUS 0263 CLTZ 600 ZF18K4E-TFD 6.0 17.2 5850 SCS2150 1052 914 723 POA

CUS 0265 CLTZ 750 ZF24K4E-TFD 7.5 20.9 7110 SCT2170 1269 914 723 POA

CUS 0268 CLTZ 1000 ZF33K4E-TFD 10.0 28.9 9670 SCT2215 1269 914 723 POA

CUS 0270 CLTZ 1300 ZF40K4E-TFD 13.0 35.6 12090 SCR2275 1484 1034 776 POA

CUS 0273 CLTZ 1500 ZF48K4E-TFD 15.0 42.1 14950 SCR2385 1484 1034 928 POA

• Note that all capacities are rated at 30°C ambient, 10K useful superheat, 2K sub-cooling.

• For complete technical data, refer to appendix TD227.

• For accessories, refer to CP215 & CP216.

CP204

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD CUSTOM BUILD SEMI-SEALED UNITS

Custom Design & Build Service

Frascold semi-sealed condensing units, are designed and manufactured in New Zealand, using Frascold Compressors. All units can be manufactured to suit your individual requirements. Refer to the following accessory pages for options and pricing. (Note Condensing units must be selected on rated capacity NOT nominal HP rating).

Frascold Condensing Units include:

• UnitsfittedwithFrascoldrefrigerationratedsemi-sealedcompressors (not ZR air con rated models)

• Allunitsfittedwithdualpressurecontrols

• Receiveroutletvalve

• CompressorRotolockvalves

• Oilandsightglass

• UnitwarrantyasperpageCP225

Low Clearance High Capacity Piston Valve Plate Assembly features on all Frascold compressors. Specially contoured pistons and low cylinder clearance = increased capacity.

EC 93/68/CEE

Underwriters Laboratory

R404a R407A R407B R407c R134a R507

CP205

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD CUSTOM BUILD SEMI-SEALED UNITS

R404a Medium TemperatureRealcoldStock No.

Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ -5°C SST

Condenser Dimensions (mm) System Price$ Excl. Gst

L W H

220/240 Volt 50Hz Single Phase

C5317M SAR16A 1.0 5.47 3270 SCN148 570 415 405 POA

C5323M SAR157A 1.5 6.91 4100 SCS158 974 649 519 POA

380/415 Volt 50Hz Three Phase

C5329M SAR157A 1.5 6.91 4100 SCS158 974 649 519 POA

C5333M SAR210B 2.0 9.84 6090 SCT189 974 665 620 POA

C5346M SAR313D 3.0 13.84 8150 SCT1120 974 1052 620 POA

C5349M SAR418D 4.0 17.83 9990 SCT2170 914 1269 723 POA

C5359M SAR524F 5.0 23.60 14790 SCT2215 914 1269 723 POA

C5362M SAR728Q 7.5 27.31 17110 SCT2215 914 1269 723 POA

C5366M SAR733S 7.5 32.80 20690 SCR2275 1034 1469 775 POA

C5374M SAR1039S 10.0 38.25 23650 SCR2385 1034 1469 928 POA

C5379M SAR1551S 15.0 50.43 30910 SCR2475 1034 1469 1028 POA

*C5382M SAR2059V 20.0 58.48 36710 SCV2720 1096 2154 965 POA

*C5386M SAR2571V 25.0 70.97 44540 SCV2720 1096 2154 965 POA

*C5387M SAR3084V 30.0 83.81 53000 SCV2850 1096 2154 1065 POA

*C5390M SAR35106Z 35.0 106.16 63410 SCV2850 1096 2154 1065 POA

R404a Low TemperatureRealcoldStock No.

Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ -25°C SST

Condenser Dimensions (mm) System Price$ Excl. Gst

L W H

220/240 Volt 50Hz Single Phase

C5319L SAR159B 1.5 8.96 2320 SCS158 974 649 519 POA

380/415 Volt 50Hz Three Phase

C5321L SAR159B 1.5 8.96 2320 SCS158 974 649 519 POA

C5337L SAR213D 2.0 13.84 3550 SCT189 974 649 620 POA

C5341L SAR318D 3.0 17.83 4850 SCT1120 974 649 620 POA

C5351L SAR424F 4.0 23.60 6580 SCS2150 914 1052 723 POA

C5362L SAR528Q 5.0 27.31 7430 SCS2150 914 1052 519 POA

C5366L SAR733S 7.5 32.80 8800 SCT2170 914 1269 723 POA

C5368L SAR739S 7.5 38.25 10820 SCT2215 914 1269 723 POA

C5377L SAR1051S 10.0 50.43 14080 SCT2255 914 1269 723 POA

*C5380L SAR1559V 15.0 58.48 15700 SCR2275 1034 1484 776 POA

*C5381L SAR1571V 15.0 70.77 19380 SCR2385 1034 1484 928 POA

*C5384L SAR2084V 20.0 83.81 22500 SCR2475 1034 1484 1028 POA

*C5389L SAR25106Z 25.0 106.16 29350 SCV2720 1096 2154 965 POA

*C5391L SAR30126Z 30.0 125.72 35020 SCV2850 1096 2154 1065 POA

*C5393L SAR40154Z 40.0 154.38 41660 SCV2850 1096 2154 1065 POA* Units fitted with Oil Pressure Safety Control.

• Note that all capacities are rated at 30°C ambient, 10K useful superheat, 2K sub-cooling

• For complete technical data, refer to appendix TD228.

• For accessories, refer to CP215 & CP216.

CP206

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD SEMI-SEALED COMPRESSOR RECEIVER PACKAGES

R404a Medium / Low TempRealcoldStock No.

Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ +40°C SCT (W)

R404a Pump Down Capacity (Kg)

Application System Price$ Excl. Gst

-5°C SST -25°C SST R404a R22 R134a

C5429 CR728Q 7.5 29.36 18390 7510 33 HML HML HM POA

C5433 CR733S 7.5 32.80 21870 8770 33 HML HML HM POA

C5434 CR739S 7.5 38.25 - 10850 33 L L HM POA

C5439 CR1039S 10 38.25 25900 10690 54 M HML HM POA

C5442 CR1051S 10 50.43 - 14120 54 L L HM POA

C5444 CR1551S 15 50.43 33400 13480 54 M M HM POA

*C5445 CR1559V 15 58.84 - 16160 54 ML ML HM POA

*C5450 CR1571V 15 70.77 - 19440 54 L ML HM POA

*C5455 CR2059V 20 58.84 39220 15790 80 HML HML HM POA

*C5462 CR2084V 20 83.81 - 23410 80 L ML HM POA

*C5464 CR2571V 25 70.77 46620 18780 80 HML HM HM POA

*C5466 CR3084V 30 83.81 55710 22770 80 HML HM HM POA

*C5467 CR25106Z 25 106.16 - 28960 80 L ML HM POA

*C5468 CR30126Z 30 125.72 - 34760 80 L ML HM POA

*C5470 CR35106Z 35 106.16 70460 28350 105 HML HM HM POA

*C5475 CR40126Z 40 125.72 84730 34190 105 HML HM HM POA

*C5477 CR40154Z 40 154.38 - 43400 80 ML ML HM POA

*C5480 CR50154Z 50 154.38 104410 41970 105 ML HM HM POA

*C5482 CR50187W 50 186.10 - 53080 105 L L M POA

*C5485 CR60187W 60 186.10 127640 51100 105 ML ML HM POA

*C5488 CR60206W 60 205.80 - 58650 105 L L HM POA

*C5491 CR70206W 70 205.80 140220 56640 105 ML HM HM POA* Compressor fitted with Oil Pressure Safety Control.

Realcold Semi-Sealed Compressor Receiver Packages

• CompressorReceiverPackagesaresuppliedcompletewithtwoRotolockvalves,aPressureReliefValveandaDualPressureControl. Oil Protection Controls fitted to V/Z & W only.

• ReceiversaredesignedandconstructedinaccordancewiththerequirementsofBS5500(1988).

• Refrigeration capacities rated @ 40°C condensing temperature, 2°Csub-cooled liquid, 10°C useful superheat.

• RefertopageCP207foraccessories.

• Seewarrantysectionofcatalogueforwarrantydetails.

• Note: Custom Built Parallel Racks are available - please talk with our Technical Applications Engineers who will be happy to discuss options with you.

CP207

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD SEMI-SEALED, COPELAND SCROLL UNIT ACCESSORIES

Liquid Line Assembly - Medium & Low Temp ModelsIncludes Drier, Liquid Moisture Indicator, Solenoid Valve, Pipework Fitted

RealcoldStock No.

Line Size Drier Size Refillable Shell Suits Models System Price$ Excl. Gst

C5901 1/4" Assy DCY052 - 0.75 HP 289.68

C5903 3/8" Assy DCY083 - 1.5 HP to 2 HP 315.18

C5904 1/2" Assy DCY084 - 2 HP to 5 HP 325.38

C5906 1/2" Assy DCY414 - 5 HP to 7.5 HP 365.16

C5908 5/8" Assy DCY415 - 7.5 HP Medium Temp Only

416.16

C5909 5/8" Assy BCY485S One 10 HP to 20 HP Medium Temp Only

613.02

C5911 7/8" Assy BCY9675 Two 20 HP to 40 HP 678.30

C5912 1 1/8" Assy BCY9695 Two 40 HP to 70 HP Low Temp Only

742.56

C5913 1 3/8" Assy C-14411G Three 60 HP to 70 HP Medium Temp Only

1,050.60

Note: Low Temperature -25°C Evap. Medium Temperature -5°C Evap.

Oil Separator AssemblyIncludes Oil Separator, Vibration Eliminator, Pipework Fitted

RealcoldStock No.

Line Size Suits HP System Price$ Excl. Gst

C5931 1/2" 1 HP to 1 1/2 HP 329.46

C5932 5/8" 2 HP to 3 HP 335.58

C5933 7/8" 4 HP to 5 HP 422.28

C5934 1 1/8" 7 1/2 HP to 20 HP 482.46

C5935 1 3/8" 25 HP to 35 HP 563.04

C5936 1 5/8" 40 HP to 50 HP 728.28

C5937 2 1/8" 50 HP to 60 HP 918.00

C5938 2 5/8" 60 HP to 70 HP 1,868.64

Oil Return Line SightglassRealcoldStock No.

Line Size Suits HP System Price$ Excl. Gst

C5995 3/8” sweat. All models 3/4 HP to 10 HP 69.36

Suction Line AssemblySuits Models Up To SAR1051S. Includes Accumulator, Vibration Eliminator and Pipework Fitted

RealcoldStock No.

Line Size Suits Models System Price$ Excl. Gst

C5945 5/8" Assy 1.5 HP 235.62

C5946 3/4" Assy 2 HP Medium Temp Only 239.70

C5947 7/8" Assy 2 HP Low Temp Only 278.46

C5948 1 1/8" Assy 3 HP to 6 HP 302.94

C5949 1 3/8" Assy 7.5 HP to 15 HP 425.34

CP208

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD SEMI-SEALED, COPELAND SCROLL UNIT ACCESSORIES

Suction Line Refillable Filter AssemblySuits models SA728F up to CR70206W. Includes Refillable Filter, Accumulator, Vibration Eliminator and Pipework Fitted

RealcoldStock No.

Line Size Suits Models System Price$ Excl. Gst

C5956 1 3/8" Assy (c/w one core drier) 6 HP to 10 HP 721.14

C5957 1 5/8" Assy (c/w one core drier) 15 HP to 20 HP 817.02

C5958 2 1/8" Assy (c/w one core drier) 25 HP to 35 HP 1,504.50

C5959 2 5/8" Assy (c/w two core drier) 40 HP to 50 HP 2,642.82

C5961 3 1/8" Assy (c/w two core drier) 50 HP to 70 HP 2,771.34

Suction Line Filter Fitted AssemblyIncludes Filter and Pipework Fitted

RealcoldStock No.

Line Size Suits Models System Price$ Excl. Gst

C5966 5/8" Assy 1.5 HP 102.46

C5968 7/8" Assy 2 HP 105.06

C5969 1 1/8" Assy 3 HP to 5 HP 110.16

C5970 1 3/8" Assy 7.5 HP to 10 HP 114.24

Pressure ControlsRealcoldStock No.

Description System Price$ Excl. Gst

C5987 LP Pump Down Control - Fitted 130.56

C5988 HP Condenser Fan Control - Fitted 131.58

C5989 HP/LP Control Fitted 187.68

Capacity ControlsRealcoldStock No.

Description System Price$ Excl. Gst

C5221 To suit “T” & “S” Series (Mk II) 1 cylinder head c/w solenoid 50% control 402.90

C5225 To suit “Z” & “V” & “W” Series 1 head only.

1 head for “V”=50% control.

1 head for “Z” = 33% control

2 heads for “Z”=33% & 66% control (Z:33%+66% = 2 x C5225)

2 heads for “W”=50% & 75% control (W:50%+75% = 2 x C5225

430.44

MiscellaneousRealcoldStock No.

Description System Price$ Excl. Gst

R0316 Rubber Mounts 40 x 40 mm, 2 - 3HP 35.75

R0552 Crankcase Heater F, S, T Series, 70 Watt, Fitted 160.14

R0553 Crankcase Heater A, B, D Series, 50 Watt, Fitted 160.14

R0555 Crankcase Heater (to suit V, W, Z Series) MK 2, 150 Watt Plain Shank, Fitted 238.68

C5805 Head Cooling Fan (to suit A, B, D, F Series), Fitted 514.08

C5808 Head Cooling Fan (to suit S, T, V, Z Series), Fitted 532.44

R0824 Delta-P Oil Differential Pressure Switch (to suit V, Z and W Series) 536.52

CP209

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD AIR COOLED CONDENSERS

Realcold Air Cooled Condensers Feature:

Manufactured by Steelfort, well known for its quality and innovation, these Air Cooled Condensers are the brand of

choice for a wide range of applications. Features include:

Casing: The casing is made from the highest quality aluminium construction, utilising rust free stainless steel fasteners throughout.

Heat Exchange Element (coil): Die formed plate type aluminium fins mechanically bonded to high efficiency inner grooved (rifled) copper tube.

Optional Epoxy Coated Aluminium Fins: For added protection in salt laden or polluted atmospheres.

Fans: Standard 630 diameter basket grill. Optional Ziehl or EC fans on request.

Custom built: Custom built units outside the standard range available on request.

Vertical DischargeRealcoldStock No.

Model Capacity kW @ 15KTD

Air Flow No.Fans Total Amps Dimensions (mm) System Price$ Excl. Gst

L D H

C5660 SCV 2100 100 6.6 2 3.6/ph. 2064 1243 1210 6,962.52

C5661 SCV 2115 115 6.9 2 3.6/ph. 2257 1243 1210 8,658.78

C5662 SCV 3145 144 10.4 3 5.4/ph. 3064 1243 1210 9,284.04

C5663 SCV 3160 162 9.9 3 5.4/ph. 3064 1243 1210 10,887.48

C5664 SCV 4200 196 12.8 4 7.2/ph. 3664 1243 1210 12,582.72

C5665 SCV 5230 230 17.5 5 9.0/ph. 4564 1243 1210 13,360.98

Dual Series

C5670 SCV 4200-2 200 13.2 4 7.2/ph. 2064 1243 1210 13,803.66

C5671 SCV 6280 288 20.8 6 7.2/ph. 3064 1243 1210 18,185.58

C5672 SCV 6320 324 19.8 6 10.8/ph. 3064 1243 1210 21,772.92

C5673 SCV 8390 392 25.6 8 14.4/ph. 3664 1243 1210 24,857.40

C5674 SCV 10460 460 35.0 10 18.0/ph. 4564 1243 1210 26,033.46

Note: For complete technical data, refer to Appendix TD235 - TD238.

Condensers - Ammonia

• Realcold is able to offer a range of Ammonia Air Cooled Condensers.

• Please contact the Realcold Technical Team if you would like to discuss this option in more detail and they will offer advice and solutions for you.

CP210

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD AIR COOLED CONDENSERS

Horizontal DischargeRealcoldStock No.

Model R404a Capacity in Watts @ 15°KTD

FansNo. / DiaNo. / mm

Dimensions (mm) System Price$ Excl. Gst

L D H

Single Phase

C8013 SCT 168 6659 1 x 400 630 205 530 684.42

C8015 SCT 189 8717 1 x 400 630 205 530 770.10

C8017 SCT 1120 11951 1 x 400 630 205 530 951.66

C8019 SCS 2120 11657 2 x 350 980 205 430 1,025.10

C8021 SCS 2150 14406 2 x 350 980 205 430 1,133.22

C8023 SCT 2170 16758 2 x 400 1200 205 635 1,207.68

C8025 SCT 2215 20977 2 x 400 1200 205 635 1,387.20

C8027 SCT 2255 25093 2 x 400 1200 205 635 1,569.78

C8029 SCR 2275 27500 2 x 500 1400 285 635 2,517.36

C8031 SCR 2385 38500 2 x 500 1400 285 840 3,000.84

C8033 SCR 2475 47250 2 x 500 1400 255 940 3,478.20

Three Phase

C8041 SCV 2720 72030 2 x 630 2050 285 840 4,663.44

C8043 SCV 2850 84481 2 x 630 2050 285 940 5,632.44

• All fans up to 500 mm 230V 1PH and 630 mm 400V 3PH.

• All Condensers fitted with fan motors and guards. Gussetts to be ordered extra.

• For complete technical data, refer to Appendix TD235 - TD238.

Hanwest Water Cooled Marine CondenserHanwest incorporates the latest in refrigerant heat exchanger technology. Compact, with high level of heat exchanger efficiency using cupro nickel tube. The best marine water cooled condensers for refrigeration or air conditioning installations. Ratings Based on Water Entering Temperature 30°C and 42°C Condensing.

RealcoldStock No.

Model Water Flow Rate Watts @ 10 KTD System Price$ Excl. Gst

F2002 CN2 0.16 L/sec 4836 775.20

F2003* CN3 0.20 L/sec 7000 831.30

F2004* CN4 0.17 L/sec 8250 955.74

F2005* CN5 0.37 L/sec 15800 1,091.40

F2006* CN6 0.62 L/sec 21100 1,227.06

F2010 Parallel Manifold 1" BSPT for CN2 36.26* These models are available on an indent basis only.

CP211

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD EVAPORATOR UNITS

Realcold Evaporator Coils Units Feature:

• Compactsizetocoolingcapacityratio.

• Excellentsurfaceareatocoolingcapacityratio.

• Hingeddrainpanwith“thumbscrews”foreasyaccesstodefrostelementsandcondensatepan.

• Hingedsidecoverswith“thumbscrews”foreasyaccesstoTEV,heatersafetyKlixon.

• Motorsanddefrostelementsareallpre-wiredtoterminalconnectionsintheelectricalbox.

• 1/4”accessportonallcoilsisastandardfeatureforcheckingin-coilpressuresandsettingupsuperheats.

• Flat4mmslottedmountingbrackets forveryquickeasy installation.Topof evaporator coil only 4 mm from ceiling panel easy to seal for hygiene purposes.

• Standard4.2mm fin spacingonmedium temperatureand low tem-perature models, easily inter-changed from low to medium temperature applications. Alternative fin spacing available on request.

• Lightweightconstruction,eventhelargecapacitycoilsareeasytolift,rangefrom 17-75 Kg on the N Series range, 92-98 Kg on the S Series range, 132-242 Kg on the R Series range and 242-510 Kg on the V Series range.

Rondo Two Fan HCT

Rondo Single Fan

HDT

CP212

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD EVAPORATOR UNITS

HCT Series - Medium Temp - No DefrostRealcoldStock No.

Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

W4600 HCT-251-2R 418 410 425 450 175 9.5 9.5 12.7 5.5 0.6 357.00

W4603 HCT-252-2R 990 970 750 450 175 9.5 9.5 12.7 11 1.0 554.88

W4605 HCT-252-3R 1235 1210 750 450 175 9.5 9.5 12.7 16 1.3 598.74

W4607 HCT-253-3R 1857 1820 750 450 175 9.5 12.5 20 20 1.9 823.14

W4609 HCT-254-3R 2480 2430 1400 450 175 9.5 12.5 20 30 2.0 1,066.92

HCT Series - Low Temp - Full Electric DefrostRealcoldStock No.

Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -24SST / 6KTD R404a

W4604 HCT-252-2RE - 830 750 450 175 9.5 9.5 20 11 1 722.16

W4606 HCT-252-3RE - 1016 750 450 175 9.5 12.5 20 16 1.3 766.02

W4608 HCT-253-3RE - 1528 1075 450 175 9.5 12.5 20 16 1.9 1,060.80

W4610 HCT-254-3RE - 2041 1400 450 175 9.5 12.5 20 16 2.3 1,378.02

Rondo Series - Medium Temp - No DefrostRealcoldStock No.

Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

W4000 Rondo 240 837 820 450 440 115 9.5 9.5 12.5 5.1 1.2 533.46

W4002 Rondo 340 1133 1110 450 440 140 9.5 9.5 12.5 6.2 1.2 564.06

W4008 Rondo 440 1476 1446 450 440 165 9.5 9.5 12.5 9 1.5 593.64

W4009 Rondo 500 1926 1887 760 430 170 9.5 9.5 12.5 11 2.0 657.90

W4010 Rondo 700 2372 2325 760 430 220 9.5 9.5 12.5 13 4.0 912.90

W4012 Rondo 900 3020 2960 1060 530 240 9.5 9.5 12.5 27 7.0 1,237.26

TM Dual Discharge - Medium Temp - Air DefrostRealcoldStock No.

Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

W5500 TM140 4165 4082 1224 845 355 12.7 22.3 20 38 2.0 1,440.24

W5502 TM270 7143 7000 1705 850 360 12.7 22.3 20 59 3.0 2,283.78

W5504 TM3100 10204 10000 2205 850 360 12.7 28.1 20 85 4.2 3,178.32

W5508 TM4140 14286 14000 2705 850 360 12.7 28.1 20 121 6.0 4,114.68

Note: For complete technical data, refer to Appendix TD239 - TD243.

CP213

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD EVAPORATOR UNITS - N SERIES

N Series Medium Temp - Air DefrostRealcoldStock No.

Model Intern / Extern

Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -4 SST / 6 KTD

W5000 NM114 Intern 1400 1372 770 400 395 12.7 15.9 20 17 0.19 622.20

W5002 NM117 Intern 1690 1656 770 400 395 12.7 15.9 20 18 0.25 676.26

W5004 NM121 Intern 2090 2048 770 400 395 12.7 15.9 20 19 0.32 778.26

W5006 NM124 Intern 2370 2323 975 400 395 12.7 15.9 20 21 0.33 826.20

W5008 NM127 Intern 2710 2656 975 400 395 12.7 15.9 20 23 0.41 889.44

W5010 NM232 Intern 3200 3136 1270 400 395 12.7 15.9 20 25 0.34 1,026.12

W5012 NM240 Extern 3950 3871 1270 400 395 12.7 15.9 20 27 0.46 1,096.50

W5014 NM245 Extern 4520 4430 1270 400 395 12.7 22.3 20 29 0.58 1.181.16

W5016 NM254 Extern 5450 5341 1770 400 395 12.7 22.3 20 44 0.67 1,402.50

W5018 NM464 Extern 6400 6272 2270 400 395 12.7 22.3 20 50 0.66 1,622.82

W5020 NM374 Extern 7400 7252 1770 400 395 12.7 22.3 20 47 0.84 1,659.54

W5022 NM479 Extern 7895 7737 2270 400 395 15.9 28.1 20 58 0.88 1,801.32

N Series - Low Temp - Full Electric DefrostRealcoldStock No.

Model Intern / Extern

Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -24 SST / 6KTD

W5050 NL112 Intern - 1210 770 400 395 12.7 15.9 20 17 0.53 836.40

W5052 NL115 Intern - 1455 770 400 395 12.7 15.9 20 18 0.70 900.66

W5054 NL118 Intern - 1800 770 400 395 12.7 15.9 20 19 0.88 1,006.74

W5056 NL120 Intern - 2040 975 400 395 12.7 15.9 20 21 0.93 1,084.26

W5058 NL123 Intern - 2330 975 400 395 12.7 15.9 20 23 1.15 1,147.50

W5060 NL228 Intern - 2760 1270 400 395 12.7 15.9 20 29 0.95 1,328.04

W5062 NL234 Extern - 3400 1270 400 395 12.7 15.9 20 31 1.28 1,405.56

W5064 NL239 Extern - 3890 1270 400 395 12.7 22.3 20 33 1.60 1,492.26

W5066 NL347 Extern - 4695 1770 400 395 12.7 22.3 20 44 1.85 1,793.16

W5068 NL455 Extern - 5520 2270 400 395 12.7 22.3 20 50 1.83 2,134.86

W5070 NL364 Extern - 6375 1770 400 395 12.7 22.3 20 47 2.50 2,080.80

W5072 NL468 Extern - 6800 2270 400 395 15.9 28.1 20 58 3.00 2,332.74

Note: For complete technical data, refer to Appendix TD239 - TD243.

CP214

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD EVAPORATOR UNITS - S SERIES

S Series - Medium Temp - Air DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity At -4 SST / 6K TD

W5024 SM271 7102 6960 1483 482 510 12.7 22.3 20 48 2.97 1,643.22

W5026 SM386 8599 8427 2233 482 510 15.9 29 20 71 3.57 2,138.94

W5028 SM3105 10653 10440 2233 482 510 15.9 35 20 75 4.2 2,388.84

W5030 SM3125 12434 12185 2233 482 510 15.9 35 20 79 5.25 2,724.42

W5032 SM4140 14204 13920 2731 482 510 15.9 35 20 92 5.79 2,979.42

W5034 SM4165 16574 16243 2731 482 510 15.9 35 20 98 6.93 3,343.56

W5036 SM5210 21179 20340 3223 482 510 15.9 35 40 121 9.18 3,520.02

S Series - Medium Temp - Partial DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -4 SST / 6KTD

W5200 SM271P 7102 6960 1483 482 510 12.7 22.3 20 48 3.0 1,815.60

W5202 SM386P 8599 8427 2233 482 510 15.9 29 20 71 3.6 2,382.72

W5204 SM3105P 10653 10440 2233 482 510 15.9 35 20 75 4.2 2,632.62

W5206 SM3125P 12434 12185 2233 482 510 15.9 35 20 79 5.3 2,968.20

W5208 SM4140P 14204 13920 2731 482 510 15.9 35 40 92 5.8 3,305.82

W5210 SM4165P 16574 16243 2731 482 510 15.9 35 40 98 6.9 3,669.96

W5212 SM 5210P 18200 17836 3223 482 510 15.9 35 40 121 9.2 4,178.94

S Series - Low Temp - Full Electric DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -24 SST / 6KTD

W5074 SL261 6119.39 - 1483 482 510 12.7 22.3 20 48 2.48 2,015.52

W5076 SL374 7409.18 - 2233 482 510 15.9 29 20 71 2.98 2,650.98

W5078 SL392 9178.57 - 2233 482 510 15.9 35 20 75 3.50 2,900.88

W5080 SL3110 10713.27 - 2233 482 510 15.9 35 20 79 4.38 3,237.48

W5082 SL4120 12238.78 - 2723 482 510 15.9 35 40 92 4.83 3,668.94

W5084 SL4145 14281.63 - 2723 482 510 15.9 35 40 98 5.78 4,035.12

W5086 SL5180 17836.00 - 3290 440 535 15.9 35 40 121 9.20 4,264.62

Note: For complete technical data, refer to Appendix TD239 - TD243.

CP215

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

REALCOLD EVAPORATOR UNITS - R & V SERIES

R Series - Medium Temp - Air DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -4 SST / 6KTD

W5230 RM2140 14000 13333 2210 670 805 16 29 40 132 6.10 4,622.64

W5232 RM3185 18400 17524 2240 685 1075 16 35 40 173 7.40 5,582.46

W5234 RM3210 20600 19619 2740 685 1075 16 35 40 196 8.80 6,176.10

W5236 RM3230 23100 22000 2740 685 1075 16 35 40 198 9.90 7,183.86

W5238 RM3250 25200 24000 2740 685 1075 16 35 40 242 11.00 6,879.90

W5240 RM4280 28100 26762 2740 685 1075 16 35 40 242 11.00 8,046.78

V Series - Medium Temp - Air DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -4 SST / 6KTD

W5242 VM2310 31000 29524 2240 775 1305 16 35 40 280 14.5 8,334.42

W5244 VM2340 34400 32762 2240 775 1305 16 41 40 340 15.0 9,309.54

W5246 VM3400 40000 38095 3240 775 1305 16 41 40 420 17.0 9,582.90

W5248 VM3450 45100 42952 3240 775 1305 16 X 2 35 X 2 40 420 19.0 10,525.38

W5250 VM3480 48300 46000 3600 775 1305 16 X 2 35 X 2 40 430 19.0 11,197.56

W5252 VM4520 52000 49524 3600 775 1305 16 X 2 35 X 2 40 430 22.0 11,502.54

W5254 VM4560 56000 53333 3890 775 1305 16 X 2 35 X 2 40 510 28.0 12,028.86

V Series - Low Temp - Electric DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -24 SST / 6KTD

W5270 VL2280 28000 - 2240 775 1305 16 35 40 242 14.5 9,453.36

W5272 VL2300 30000 - 2740 775 1305 16 41 40 290 15.0 10,493.76

W5274 VL3350 35000 - 3240 775 1305 16 41 40 345 17.0 10,829.34

W5276 VL3400 40000 - 3240 775 1305 16 X 2 35 X 2 40 345 19.0 11,773.86

W5278 VL4450 45000 - 3600 775 1305 16 X 2 35 X 2 40 430 20.0 12,909.12

W5280 VL4500 50000 - 3890 775 1305 16 X 2 35 X 2 40 430 22.0 13,548.66

Note: Optional 2 speed Ziehl plate axial or EC fans available for R and V evaps series on request. For complete technical data, refer to Appendix TD239 - TD243.

R Series - Low Temp - Electric DefrostRealcoldStock No.

Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)

Weight (Kg)

Charge R404a (Kg)

System Price$ Excl. GST

134a 404a L W H Inlet Outlet

Capacity at -24 SST / 6KTD

W5260 RL3160 16200 - 2740 670 805 16 35 40 173 7.4 6,664.68

W5262 RL3185 18500 - 3240 670 805 16 35 40 196 8.8 7,263.42

W5264 RL3200 19700 - 2740 685 1075 16 35 40 198 9.9 8,142.66

W5266 RL4220 21700 - 3240 685 1075 16 35 40 198 11.0 7,870.32

W5268 RL4250 24700 - 3240 685 1075 16 35 40 242 12.0 9,038.22

CP216

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

HC EVAPORATOR RANGE

Realcold Medium Temperature EvaporatorsRealcoldStock No.

Model Capacity @ 6KTD Fans(mm)

Air Volume(M³ / Sec)

Dimensions (mm) Weight (Kg)

Connections System Price$ Excl. GST

R404a R134a L W H Liquid Suction

Low Silotte Ceiling Mount

W4600 HCT - 251 - 2R 410 390 1 x 250 0.14 425 450 177 5.2 3/8 3/8 365.93W4603 HCT - 252 - 2R 970 923 2 x 250 0.28 750 450 177 7.8 1/2 1/2 568.75W4605 HCT - 252 - 3R 1210 1151 2 x 250 0.24 750 450 177 8.4 1/2 1/2 613.71W4607 HCT - 253 - 3R 1820 1732 3 x 250 0.36 1075 450 177 11.7 1/2 1/2 843.72W4609 HCT - 254 - 3R 2430 2312 4 x 250 0.49 1400 450 177 15 1/2 1/2 1,093.59

RondoW4001 Ron - 140-A 630 599 1 x 250 0.21 455 440 120 4 3/8 3/8 412.00W4000 Ron - 240-A 800 761 1 x 250 0.19 455 440 120 4.5 3/8 3/8 546.80W4002 Ron - 340-A 950 904 1 x 250 0.21 455 440 145 5 1/2 1/2 578.16W4008 Ron - 440-A 1080 1028 1 x 250 0.22 455 440 170 5.5 1/2 1/2 608.48W4009 Ron - 500-A 1660 1579 2 x 250 0.37 760 430 175 8.3 1/2 1/2 674.35W4010 Ron - 700-A 2060 1960 2 x 250 0.43 760 430 230 9.4 1/2 5/8 935.72W4012 Ron - 900-A 3380 3216 2 x 300 0.92 1060 530 230 14 1/2 5/8 1,268.19W4013 Ron - 1100-A 4040 3844 2 x 300 1.05 1060 530 265 15.4 1/2 3/4 1,300.00W4014 Ron - 1300-A 4640 4414 2 x 300 0.94 1060 530 265 17.4 1/2 3/4 1,370.00

Dual DischargeW5500 HDD - 351 - 4R 4070 3872 1 x 350 0.75 954 1200 350 26 1/2 7/8 3,440.00W5502 HDD - 352 - 3R 8160 7763 2 x 350 1.5 1495 1200 350 42 1/2 1.1/8 3,872.00W5504 HDD - 353 - 3R 10580 10066 3 x 350 2.34 2035 1200 350 53 5/8 1.1/8 4,410.00W5508 HDD - 353 - 6R 14080 13396 3 x 350 2.1 2035 1200 350 69 5/8 1.1/8 5,100.00

HSR Range W5002 HSR - 301 - 3R 1810 1722 1 x 300 0.48 874 405 476 17 1/2 5/8 814.82W5004 HSR - 301 - 4R 2090 1988 1 x 300 0.44 874 405 476 18 1/2 7/8 819.25W5006 HSR - 301 - 5R 2290 2179 1 x 300 0.41 874 405 476 19 1/2 7/8 901.58W5010 HSR - 302 - 3R 3650 3473 2 x 300 0.96 1376 405 476 26 1/2 7/8 1,180.47W5012 HSR - 302 - 4R 4220 4015 2 x 300 0.88 1376 405 476 29 1/2 7/8 1,290.99W5014 HSR - 302 - 5R 4600 4376 2 x 300 0.82 1376 405 476 31 1/2 7/8 1,189.31W5016 HSR - 303 - 3R 5490 5223 3 x 300 1.44 1884 405 476 35 1/2 1.1/8 1,306.46W5018 HSR - 303 - 4R 6340 6032 3 x 300 1.32 1884 405 476 39 1/2 1.1/8 1,762.80W5020 HSR - 303 - 5R 6910 6574 3 x 300 1.23 1884 405 476 42 1/2 1.1/8 1,703.51W5024 HSR - 352 - 4R 6540 6222 2 x 350 1.42 1455 405 581 38 1/2 1.1/8 2,133.89W5026 HSR - 352 - 6R 7700 7326 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 2,160.42W5028 HSR - 353 - 4R 9830 9352 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 2,465.47W5030 HSR - 353 - 6R 11580 11017 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 2,881.59W5032 HSR - 354 - 4R 13140 12501 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,094.79W5034 HSR - 354 - 6R 15440 14690 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 3,608.72

Partial Defrost OptionsW5200 HSR - 352 - 4R 6540 6222 2 x 350 1.42 1455 405 581 38 1/2 1.1/8 2,133.89W5202 HSR - 352 - 6R 7700 7326 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 2,160.42W5204 HSR - 353 - 4R 9830 9352 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 2,465.47W5206 HSR - 353 - 6R 11580 11017 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 2,881.59W5208 HSR - 354 - 4R 13140 12501 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,094.79W5210 HSR - 354 - 6R 15440 14690 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 3,608.72

HSR 3 Phase fansW5232 HSR - 502 - 4R 16650 15841 2 x 500 4.42 2230 555 690 132 5/8 1.3/8 5,342.84W5234 HSR - 502 - 6R 20290 19304 2 x 500 3.98 2230 555 690 143 7/8 1.3/8 5,388.72W5236 HSR - 503 - 4R 23810 22653 3 x 500 6.5 3000 555 690 200 7/8 2.1/8 6,172.72

CP217

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

HC EVAPORATOR RANGE

Realcold Low Temperature EvaporatorsRealcoldStock No.

Model Capacity @ 6KTD

Fans(mm)

Air Volume(M³ / Sec)

Dimensions (mm) Weight (Kg)

Connections System Price$ Excl. GST

R404a L W H Liquid Suction

HCT Range

W4604 HCT-252-2RE 970 2 x 250 0.28 750 450 177 5.2 3/8 3/8 740.21W4606 HCT-252-3RE 1210 2 x 250 0.24 750 450 177 7.8 1/2 1/2 613.71W4608 HCT-253-3RE 1820 3 x 250 0.36 1075 450 177 8.4 1/2 1/2 1,087.32W4610 HCT-254-3RE 2430 4 x 250 0.49 1400 450 177 11.7 1/2 1/2 1,412.47

HSR RangeW5054 HSR - 301 - 3RE 1810 1 x 300 0.48 874 405 476 17 1/2 5/8 1,062.20W5056 HSR - 301 - 4RE 2090 1 x 300 0.44 874 405 476 18 1/2 7/8 1,181.29W5058 HSR - 301 - 5RE 2290 1 x 300 0.41 874 405 476 19 1/2 7/8 1,262.25W5062 HSR - 302 - 3RE 3650 2 x 300 0.96 1376 405 476 26 1/2 7/8 1,481.33W5064 HSR - 302 - 4RE 4220 2 x 300 0.88 1376 405 476 29 1/2 7/8 1,644.73W5066 HSR - 302 - 5RE 4600 2 x 300 0.82 1376 405 476 31 1/2 7/8 1,705.69W5068 HSR - 303 - 3RE 5490 3 x 300 1.44 1884 405 476 35 1/2 1.1/8 2,069.34W5070 HSR - 303 - 4RE 6340 3 x 300 1.32 1884 405 476 39 1/2 1.1/8 2,233.46W5072 HSR - 303 - 5RE 6910 3 x 300 1.23 1884 405 476 42 1/2 1.1/8 2,465.39W5076 HSR - 352 - 6RE 7700 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 3,079.63W5078 HSR - 353 - 4RE 9830 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 3,045.92W5080 HSR - 353 - 6RE 11580 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 3,586.75W5082 HSR - 354 - 4RE 13140 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,769.33W5084 HSR - 354 - 6RE 15440 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 4,374.61W5260 HSR - 502 - 4RE 16650 2 x 500* 4.42 2230 555 690 132 5/8 1.3/8 7,331.15W5262 HSR - 502 - 6RE 20290 2 x 500* 3.98 2230 555 690 143 7/8 1.3/8 7,626.59W5266 HSR - 503 - 4RE 23810 3 x 500* 6.5 3000 555 690 200 7/8 2.1/8 8,263.84

* Note: 3 phase fans.

For technical diagrams refer to page TD242

CP218

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

Hoshizaki Ice Machines

Save Water Consumption: Microcomputer automatically controls volume of water during the defrost cycle. Water inlet valve saves incoming water.

Bin Control Switch: When the bin is full of ice, bin control switch detects and automatically shuts down the ice making process. Reliable mechanical switch is fitted in cubers for consistent operation.

Smart Computer Board: No need for manual adjustments. Dependable Hoshizaki computer board controls ice supply in the most efficient and produc-tive way in any condition.

Sanitary Construction: One piece insulation, snug fit top cover, magnetic door gasket and door side protector prevents incoming dust, water and insects.

Long Life Main Parts: Main parts such as compressor, fan-motor, pump-motor are uniquely designed to ensure ice cubers ‘ long life.

Easily Cleaned Air-Filter: Air filter can be cleaned easily upon removing the front cover. Clean air-filter contributes to the maximum ice making production.

ICE MACHINES

CP219

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

ICE MACHINES

Hoshizaki Ice MachinesModel Production Capacity

(Kg/Day)Bin Capacity (Kg)

Amps Dimensions (mm) Net/Gross Weight (Kg)

System Price$ Excl. Gst

A.T.21°C W.T.15°C L W H

KM Crescent Ice - Self Contained (Cube Size 30 x 37 x 13)

KM 30A 32 16 1.5 610 450 850 39/49 POA

KM 50A 50 23 2.2 610 603 850 46/58 POA

KM 75A 70 40 3.0 712 603 850 51/64 POA

KM Crescent Ice - Stack On (Cube Size 38 x 27 x 13)

KM 630 MAH E * 283 n/a 7 695 560 950 75/84 POA

KM 1300 SAH E * 544 n/a 11.5 695 1220 695 125/143 POA

IM Cube Ice - Self Contained (Cube Size 25 x 25 x 23)

IM 30 CLE - 25 20 11.5 1.8 495 398 695 35/42 POA

IM 45 LE - 25 32 18 2.1 456 503 850 54/60 POA

IM 65 LE - 25 44 26 2.4 506 633 850 63/69 POA

IM Cube Ice - Self Contained (Cube Size 21 x 21 x 14)

IM 100 LE 83 50 5.0 506 704 1200 80/90 POA

IM 130 ME 104 50 5.0 506 704 1200 80/90 POA

IM 240 M2E 205 110 6.7 670 704 1577 130/145 POA

IM Cube Ice - Stack On (Cube Size 21 x 21 x 14)

IM 240 AME (* 230 n/a 6.7 800 560 865 90/110 POA

IM 240 DME (* 230 n/a 6.7 800 1084 395 90/95 POA

FM Flaked Ice - Self Contained

FM 120 EE 109 26 2.8 600 600 800 66/76 POA

FM 120 EE - 50 109 50 2.8 600 900 800 83/93 POA

FM Flaked Ice - Stack On

FM 251 AFE (* 200 n/a 5.6 700 560 680 86/98 POA

FM 481 AGE (* 425 n/a 6.8 699 560 780 97/118 POA

FM 600 AHE (* 540 n/a 9.9 699 560 780 110/122 POA

FM 1000 ASFE3 (** 950 n/a 8.8 698 760 898 153/168 POA

DCM Cubelet Ice & Water Dispenser (Size 15x9x19)

DCM 110F 105 4 3.2 585 350 840 60/67 POANote: A.T. = Ambient Temperature, W.T. = Water Temperature * Head only & bin sold separately. (* Bin sold separately. (** Bin sold separately, 3 phase 400V & remote air cooled condenser URC 20FE required (1200 x 370 x 659 mm)

Top KitsModel Net/Gross Weight (Kg) System Price

$ Excl. Gst

Top Kit 4H-100 mm B 800PF - IM 240AME, FM600, KM630, KM900, FM1000, 2 KM630, 2 FM600, 2 IM240AME B 900PF - KM1300

POA

Top Kit 8H-200 mm B 500PF - IM 240AME, FM600, KM630 B 900PF - IM 240AME, FM600, KM630, 2 KM630, 2 FM600, 2 IM240AME

POA

Top Kit 14H-355 mm B 700PF & B 800PF - KM900, FM1000. POA

Top Kit 22H-560 mm B 700PF & B 800PF - IM 240AME, FM600, KM630 B 900PF - IM 240AME, FM600, KM630, KM900, FM1000

POA

Note: Kits are use to fill the gap large “B Series” bins leave when used with head only units.

CP220

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

ICE MACHINES

Optional Bins - Insulated, Vinyl Clad Galvanized Steel, Stainless Steel BinsModel Capacity (Kg) Compatible With Dimensions * System Price

$ Excl. GstL W H

P 200SD2 180 IM 240 DME 1080 850 800 POA

N 200A 95 IM 240 DME Bin Extension: Height = 475 POA

B 300PF 140 IM 240 AME

KM 630 MAH-E

FM 600 AHE /

FM 481

560 820 1168 POA

B 500PF 230 IM 240 AME

KM 630 MAH-E

KM 900 MAH-E

FM 600 AHE /

FM 481

FM 1000 ASFE

760 820 1168 POA

B 800PF 365 IM 240 AME

KM 630 MAH-E

KM 900 MAH-E

KM 1300 SAH-E

FM 600 AHE /

FM 481

FM 1000 ASFE

1220 820 1168 POA

B 900PF 410 IM 240 AME

KM 630 MAH-E

KM 900 MAH-E

KM 1300 SAH-E

FM 600 AHE /

FM 481

FM 1000 ASFE

1320 820 1168 POA

* Height includes adjustable feet 150-180 mm. Indent only, POA.

CP221

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

Geneglace Flake Ice Machines

What Is Flake Ice? Flake-ice is small ice in flat pieces. It is used in cooling seafood, in meat processing

and in a whole range of industrial processes. Flake-ice is dry and sub-cooled (-6°C approx). With a moderate production cost compared to most of the other kinds of ice, flake-ice is used in large quanti-ties in many industrial and food processes.

Substantial Cooling Power: Slightly sub-cooled, flake-ice is also a dry ice. The “ ice only “ feature of its manufacture means that the latent heat, the principal source of the cooling energy, is 100 % available.

Accurate Cooling: As flake-ice is dry, its cooling input can be accurately calculated and its effects on the temperature of the mixture are quickly apparent.

Easy Handling And Storage: Flake-ice is free flowing, its flakes do not stick together and form blocks. They are light and cushion the product to reduce the risk of crushing or deterioration.

The Realcold Complete Unit consists of:

• Low Temp Condensing Unit, fully connected to the Ice Generator

• Built on its own steel frame

• Fully wired package to its own control panel

• Salt Dose Pump Kit (if required)

• Unit evacuated and charged with dry nitrogen

Site Requirements:

• Refrigerant Charge

• 3 Phase electrical supply

• Fresh water supply

• Full commissioning

GENEGLACE FLAKE ICE MACHINES

Geneglace Ice Generator - InformationRealcoldStock No.

Model Water Conditions 24 HourIce Production (Kg)

Refrigerator Liquid Inlet Dimensions (mm) Net Weight (Kg)

Base Dim. (mm)

Dia. Ice Outlet (mm)

L W H

C6230 F15 Fresh water entering +15°C

350-480 R22, R404a Expansion Valve

520 360 600 50 390 x 360 240

C6232 F30V Fresh water entering +15°C

500-1000 650 500 700 90 500 x 470 340

C6234 F90H Fresh water entering +15°C

1500-3000 910 750 1250 210 680 x 680 500

C6236 F90V Fresh water entering +15°C

2700-3700 910 750 1250 210 680 x 680 500

C6240 F200 Fresh water entering +15°C

4200-7300 R22, R717,

R404a

Expansion Valve or Liquid Level Control

1200 950 1750 550 910 x 910 680

C6246 F250 Fresh water entering +15°C

6200-10000 1300 1000 2050 720 910 x 910 680

C6254 F600 Fresh water entering +15°C

7500-14000 R22, R717,

R404a

Liquid Level Control

1500 1200 2050 950 1040 x 1040 780

C6258 F800 Fresh water entering +15°C

12500-21000 1550 1550 3000 2500 1290 x 1290 930

C6262 F900 Fresh water entering +15°C

17000-30000 1950 1950 3100 3100 1580 x 1580 1200

C6268 F2000 Fresh water entering +5°C

26000-48000 2435 2435 3100 5200 2080 x 2080 1780

Note: ABF Models are for use with High Pressure Liquid, such as a TX Valve system, and include a Flood Bottle. SBF Models are for use with pumped circulation system and does not include a Flood Bottle. Salt dosing kit is common to all models. Indent only, POA.

CP222

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

CHILLED WATER PACKAGES

Chilled Water Packages Feature

• Realcold packaged liquid chillers are individually custom designed and built to meet customer requirements for each application. Integral, remote air or remote water cooled condensing is available

• Industrial type construction

• Engineered for HFC and HCFC refrigerants

• Water or glycol applications

• Self contained, complete with integral operating controls and safety devices

• Fractional HP through to large screw compressor packages

Custom Design & Build Service

Realcold offer a complete design and build facility for chilled water packages.

To assist our Technical Sales Staff in providing the best solution for your chiller and/or process needs please use the following information guide when forwarding your request. This will help ensure the best possible design and quotation is offered to you. Please do not hesitate to contact our staff should you have any queries or wish to discuss possible design options:

Ambient conditions - °C

Application - What is chiller to be used for?

Buffer tank required - Yes / No, Size?

Condensing - Water or Air cooled?

Coolant pumps - Primary and / or secondary

Coolant type - Water, Glycol, oil, other

Cooling Capacity - kW

Electrical - Level of electrical controls and safeties required.

Expected load variation - Max and minimum load percentage

Heat Exchanger type - Plate, Shell and Tube, Open type

Hygiene requirements - SS pipe, fittings, tank etc

Refrigerant - R404a, R507, R22, R134a, R407c, etc

Required flow rates - L/s, m³/hr, Kg/s

Required Temperature - Coolant supply and return temperatures

Unit location - Indoor or outdoor?

CP223

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Cap

ital P

lant

COMPRESSOR AND CONDENSING UNIT WARRANTY

CompressorsRealcold Ltd standard warranty covers start up of all compres-sors. For extended warranty the following charges apply:

Extended Warranty Charges

Sealed Compressors - All brands - 4% on sale price

Semi-Sealed Compressors - All brands - 4% on sale price

Compressors will be repaired or replaced under warranty if re-turned within 12 months of purchase date, provided that com-pressor, complete with original electrics, is returned to point of purchase, freight paid, accompanied by a compressor failure report.

Realcold Ltd shall not be held responsible for failure or damage resulting from misuse or incorrect installation.

Condensing UnitsSealed & Semi-Sealed

Warranty is included in the price listed for condensing units and includes replacement of all components for a 12 month period from date of purchase, provided component is returned along with Goods Returned Form to point of purchase, freight paid.

Note:

Replacement components will be debited against the account of the purchaser, with credit to follow upon receipt and inspection of faulty component.

Realcold Ltd shall in no event be liable for any indirect or conse-quential loss or damage whatsoever.

Refer to the back of this catalogue for our General Terms of Trade. Goods Returned Forms are available from your representative, or any of our branches.

Compressor & Condensing Unit Warranty

Tech

nical

Data

TDTD225

Tech

nica

l Dat

a

Technical DataEasypack Condensing Unit TD226

Medium Temp R404a TD226Medium Temp R134a TD226Low Temp R404a TD226

Sealed Condensing Unit Data TD227Copeland Scroll Sealed Units TD227Realpack Units TD227

Semi-Sealed Condensing Unit Data TD228Medium Temp R404a TD228Low Temp R404a TD228

Condensing Unit Capacity Tables TD231Medium Temp R404a TD231Medium Temp R134a TD231Low Temp R404a TD232

Semi-Hermetic Condensing Unit Capacity Tables TD233Medium Temp R404a TD233Low Temp R404a TD234

Standard Air Cooled Condensers TD235

Evaporator Data TD238Medium Temp TD238Low Temp TD239

Cooling Units TD240

HCT Range Unit Coolers TD242

Rondo Range Unit Coolers TD243

HDD Range Dual Discharge Coolers TD244

HSR Range Unit Coolers TD245

Small Coolroom Capacities TD246

Refrigeration Terminology TD247

Technical Tips TD248

Evaporation Superheat TD249

A Guide To Calculating Noise Levels TD250

Metric Conversion Chart TD251

General Rules & First Aid TD252

Pressure Temperature Chart TD253

Properties Of Refrigerants TD254

Conversion Data TD255

TD226

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

EASYPACK CONDENSING UNITM

odel

N

umbe

rC

ompr

esso

r M

odel

Hor

se

Pow

erD

imen

sion

s (m

m)

L x

W x

H C

apac

ity (W

), A

mbi

ent 3

2°C

Fan

(mm

)Li

quid

(m

m)

Suct

ion

(mm

)W

eigh

t (K

g)So

und

leve

l dBA

240V

-50H

z40

0V-5

0Hz

-10

-50

510

In (A

)Im

(A)

In (A

)Im

(A)

Med

ium

Tem

p R4

04a

C07

57E

CA

J 95

13 Z

1 1/

855

0 x

650

x 46

521

0824

0528

0732

2036

351

x 35

015

.99.

547

767.

310

.9-

-

C07

58E

CA

J 45

17 Z

1 1/

460

0 x

600

x 56

022

7228

4531

6836

3441

001

x 40

015

.99.

560

777.

811

.5-

-

C07

59E

CA

J 45

19 Z

1 1/

260

0 x

600

x 56

025

2636

3842

4148

6454

991

x 40

015

.99.

560

7910

.716

--

C07

62E

FH 4

524

Z2

600

x 60

0 x

560

3586

4291

5023

5786

6587

1 x

400

15.9

9.5

7379

11.7

19-

-

C07

64E

FH 4

531

Z2

1/2

600

x 60

0 x

560

4855

5850

6764

7754

8767

1 x

400

22.2

9.5

7679

14.9

27-

-

C09

54E

TFH

452

4 Z

260

0 x

600

x 56

035

8642

9150

2357

8665

871

x 40

015

.99.

573

79-

-4.

776.

77

C09

60E

TFH

453

1 Z

2 1/

260

0 x

600

x 56

048

5558

5067

6477

5487

671

x 40

022

.29.

576

82-

-5.

778.

67

C09

64E

TFH

454

0 Z

360

0 x

600

x 56

056

2867

4079

0891

4910

481

1 x

400

22.2

12.7

8082

--

8.1

9.7

C09

68E

TAG

455

3 Z

4 1/

210

80 x

680

x 5

6573

3289

4810

685

1250

914

387

2 x

400

22.2

12.7

118

84-

-8.

7514

.35

C09

71E

TAG

456

1 Z

510

80 x

680

x 5

6575

6797

1311

323

1336

515

382

2 x

400

28.6

12.7

118

84-

-10

15

C09

73E

TAG

457

3 Z

6 1/

410

80 x

680

x 5

6510

023

1203

414

168

1642

618

808

2 x

400

28.6

12.7

135

84-

-12

.35

19

C09

77E

2 xT

AG

P 45

53 Z

914

20 x

730

x 8

7013

946

1710

420

605

2420

727

667

2 x

500

28.6

15.9

213

87-

-16

.225

.5

C09

80E

2 xT

AG

P 45

61 Z

1014

20 x

730

x 8

7016

904

2022

523

683

2727

831

010

2 x

500

28.6

15.9

218

87-

-19

.525

.5

C09

85E

2 xT

AG

P 45

73 Z

1214

20 x

730

x 8

7022

356

2597

430

077

3466

539

738

2 x

500

28.6

15.9

218

87-

-23

.939

Med

ium

Tem

p R1

34a

Cap

acity

(W),

Am

bien

t 32°

C

-10

-50

510

C07

33E

FH 4

518

Y1

1/2

600

x 60

0 x

560

2514

3151

3904

4773

5759

1 x

400

15.9

9.5

7376

7.15

14.5

--

C07

37E

FH 4

525

Y2

600

x 60

0 x

560

3258

4130

5072

6131

7352

1 x

400

15.9

9.5

7878

9.15

16.5

--

Low

Tem

p R4

04a

Cap

acity

(W),

Am

bien

t 32°

C

-30

-25

-20

-15

-10

C07

87E

CA

J 24

64 Z

1 1/

255

0 x

650

x 39

511

8414

9518

4022

1226

081

x 35

015

.99.

540

766.

110

.5-

-

C07

89E

FH 2

480

Z2

600

x 60

0 x

560

1800

2271

2746

3225

3709

1 x

400

15.9

9.5

7379

8.1

17-

-

C07

93E

TFH

251

1 Z

360

0 x

600

x 56

023

5630

3037

6745

6654

271

x 40

015

.99.

580

82-

-3.

86

C07

94E

TAG

251

6 Z

410

80 x

680

x 5

6532

6841

8851

8862

6974

302

x 40

022

.29.

510

781

--

5.4

10.5

7

C07

95E

TAG

252

2 Z

510

80 x

680

x 5

6542

0254

0166

7480

1994

382

x 40

022

.29.

510

781

--

7.04

13.4

5

C07

96E

2 xT

FHP

2511

Z6

1080

x 8

00 x

570

4633

5921

7296

8619

1000

62

x 40

028

.69.

515

681

--

6.7

9.4

C07

97E

2 xT

AG

P 25

16 Z

814

20 x

730

x 8

7065

0884

1710

540

1287

815

430

2 x

500

22.2

9.5

210

82-

-11

.320

.8

C07

98E

2 xT

AG

P 25

22 Z

1014

20 x

730

x 8

7077

1398

5012

220

1482

217

658

2 x

500

28.6

15.9

215

83-

-13

.929

.5

TD227

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

SEALED CONDENSING UNIT DATA

Cop

ela

nd S

crol

l Sea

led

Uni

tsM

odel

N

umbe

rC

ompr

esso

r M

odel

Hor

se

Pow

erC

ompr

esso

r W

eigh

t (K

g)40

0V

(FLA

)C

apac

ity

R404

a (k

W)

Dis

p

(m³/

hr)

Con

dens

erC

onde

nser

Fan

sRe

ceiv

erBa

se

Mod

elD

imen

sion

s (m

m)

Mod

elH

OR

W @

15KT

DFa

ns

No

Volts

Fan

dia

(mm

)A

ir Flo

w

(L/s

)M

odel

Dia

x L

Litr

esPr

ess

Rele

ifL

WH

Med

ium

Tem

p R4

04a

SST

- 5C

CM

TZ40

0ZB

30K

QE-

TFD

441

10.3

8.53

11.8

SCS2

150

1500

02

230

350

1560

SFRH

215

0 X

800

940

0SF

B410

5291

451

9C

MTZ

500

ZB38

KQ

E-TF

D5

4212

.810

.43

14.5

SCT2

170

1700

02

230

400

2960

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

CM

TZ60

0ZB

45K

QE-

TFD

644

13.1

12.4

617

.2SC

T221

522

150

223

040

027

80SF

RH3

150

X 1

200

1440

0SF

B512

6991

472

3C

MTZ

750

ZB58

KQ

E-TF

D7.

510

015

.413

.85

20.9

SCT2

215

2215

02

230

400

2600

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

CM

TZ10

00ZB

76K

QE-

TFD

1010

221

.719

.86

28.9

SCR2

275

2750

02

230

500

3730

SFRH

315

0 X

120

014

400

SFB6

1484

1034

775

CM

TZ13

00ZB

92K

CE-

TWD

1311

225

.125

.29

35.6

SCR2

385

3850

02

230

500

3900

SFRH

315

0 X

120

014

400

SFB6

1484

1034

928

CM

TZ15

00ZB

11M

CE-

TWD

1512

029

.230

.96

42.1

SCR2

475

4750

02

230

500

3520

SFRH

315

0 X

120

014

400

SFB6

1484

1034

1028

Low

Tem

p R4

04a

SST

- 25

CC

LTZ

600

ZF18

K4E

-TFD

644

125.

8517

.2SC

S215

015

000

223

035

015

60SF

RH2

150

X 8

009

400

SFB4

1052

914

723

CLT

Z75

0ZF

24K

4E-T

FD7.

510

016

.17.

1120

.9SC

T217

017

000

223

040

029

60SF

RH3

150

X 1

200

1440

0SF

B512

6991

472

3C

LTZ

1000

ZF33

K4E

-TFD

1010

222

.39.

6728

.9SC

T221

521

500

223

040

027

80SF

RH3

150

X 1

200

1440

0SF

B512

6991

472

3C

LTZ

1300

ZF40

K4E

-TFD

1311

225

.112

.09

35.6

SCR2

275

2750

02

230

500

3730

SFRH

315

0 X

120

014

400

SFB6

1484

1034

776

CLT

Z15

00ZF

48K

4E-T

FD15

120

30.6

14.9

542

.1SC

R238

538

500

223

050

039

00SF

RH3

150

X 1

200

1440

0SF

B614

8410

3492

8

Rea

lpa

ck U

nits

Mod

el

Num

ber

Com

pres

sor

Mod

elH

orse

Po

wer

Com

pres

sor

230/

400V

(F

LA)

Volts

Pha

seC

apac

ity

R404

a (W

atts

)

Dis

p

(m³/

hr)

Con

dens

er F

ans

Liqui

d Re

ceiv

er

Capa

city

Kg

@ 8

0%

Net

t W

eigh

t (K

g)

Line

Siz

e (m

m)

Dim

ensi

ons

(mm

)So

und

Pow

er

Leve

l dB

A

Fans

N

o23

0V

MRA

Fan

dia

(mm

)A

ir Flo

w

(L/s

)Su

ctio

nLi

quid

Leng

thD

epth

Hei

ght

Med

ium

Tem

p R4

04a

SST

- 5C

RPM

125

CA

J451

7Z1.

257.

124

0V 1

PH28

6325

.95

10.

3730

039

92.

371

5/8"

3/8"

1070

480

750

65

RPM

150

CA

J451

9Z1.

59.

924

0V 1

PH37

8334

.45

10.

735

077

82.

371

5/8"

3/8"

1070

480

750

68

RPM

200

FH45

24Z

210

.324

0V 1

PH44

6043

.51

0.7

350

778

3.9

815/

8"3/

8"10

7048

075

070

RPM

250

TFH

4531

Z2.

56.

541

5V 3

PH58

1356

.65

22

x 0.

3730

085

66

105

5/8"

3/8"

1285

625

820

69

RPM

300

TFH

4540

Z3

8.9

415V

3PH

7571

74.2

52

2 x

0.7

350

1459

611

85/

8"3/

8"12

8562

582

075

RPM

450

TAG

4553

Z4.

59.

841

5V 3

PH88

5510

0.7

22

x 0.

735

014

599.

514

67/

8"1/

2"12

8562

582

078

RPM

500

TAG

4561

Z5

11.4

415V

3PH

1044

611

2.5

22

x 0.

735

014

029.

514

87/

8"1/

2"12

8562

582

078

RPM

600

TAG

4573

Z6

14.3

415V

3PH

1334

613

4.8

22

x 0.

735

014

029.

515

07/

8"1/

2"12

8562

582

077

RPM

750

2x T

AG

P454

6Z7.

52

x 8.

541

5V 3

PH15

690

2 x

90.2

22

x 3

500

3450

1225

81

1/8"

5/8"

1660

790

1015

83

RPM

100

02x

TA

GP4

561Z

102

x 11

.441

5V 3

PH20

892

2 x

112.

502

2 x

350

034

5012

261

1 1/

8"5/

8"16

6079

010

1583

RPM

125

02x

TA

GP4

573Z

122

x 14

.341

5V 3

PH26

692

2 x

134.

802

2 x

350

034

5012

265

1 1/

8"5/

8"16

6079

010

1582

Low

Tem

p R4

04a

SST

- 25

CRP

L 20

0FH

2480

Z2

11.5

240V

1PH

2296

53.2

10.

735

077

83.

990

5/8"

3/8"

1070

480

750

69

RPL

300

TFH

2511

Z3

5.1

415V

3PH

3206

74.3

22

x 0.

3730

085

66

130

5/8"

3/8"

1285

625

820

72

RPL

400

TAG

2516

Z4

7.3

415V

3PH

4498

112.

52

2 x

0.7

350

1459

615

57/

8"1/

2"12

8562

582

071

RPL

500

TAG

2522

Z5

9.4

415V

3PH

5746

134.

82

2 x

0.7

350

1402

9.5

175

7/8"

1/2"

1285

625

820

76

RPL

800

2x T

AG

P251

6Z8

2 x

7.3

415V

3PH

8874

2 x

112.

502

2 x

350

034

5012

258

1 1/

8"5/

8"16

6079

010

1579

RPL

1000

2x T

AG

P252

2Z10

2 x

9.4

415V

3PH

1169

32

x 13

4.80

22

x 3

500

3450

1225

81

1/8"

5/8"

1660

790

1015

81N

ote:

Cus

tom

des

ign

units

ava

ilabl

e fo

r spe

cial

ist a

pplic

atio

ns.

TD228

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

SEMI-SEALED CONDENSING UNIT DATAFr

asc

old

Sem

i-Se

ale

d U

nits

Mod

el

Num

ber

Com

pres

sor

Mod

elH

orse

Po

wer

Com

pres

sor

Wei

ght (

Kg)

400V

FL

AC

apac

ity

R404

a (k

W)

Dis

p

(m³/

hr)

Con

dens

erC

onde

nser

Fan

sRe

ceiv

erBa

se

Mod

elD

imen

sion

s (m

m)

Mod

elH

OR

W @

15KT

DFa

ns

No

Volts

Fan

dia

(mm

)A

ir Fl

ow

(L/s

)M

odel

Dia

x L

Litr

esPr

ess

Rele

ifL

WH

Med

ium

Tem

p R4

04a

SST

- 5C

SAR1

57A

A1.

57Y

1,5

365,

341

006,

91SC

S158

5800

123

035

081

0SF

RHI

150

X 4

005

400

SFB3

649

974

519

SAR2

10B

B21.

0Y2

385,

760

909,

84SC

T189

8900

123

040

081

0SF

RH1

150

X 4

005

400

SFB3

665

974

620

SAR3

13D

D31

3Y3

499,

681

5013

,84

SCT1

120

1200

01

230

400

1080

SFRH

115

0 X

400

540

0SF

B310

5297

462

0

SAR4

18D

D41

8Y4

5110

,599

9017

,83

SCT2

170

1700

02

230

400

2960

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

SAR5

24F

F424

Y5

7612

,214

790

23,6

SCT2

215

2215

02

230

400

2780

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

SAR7

28Q

Q72

8Y7,

579

17,5

1711

027

,31

SCT2

215

2215

02

230

400

2600

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

SAR7

33S

S733

Y7,

511

717

,520

690

32,8

SCR2

275

2750

02

230

500

3730

SFRH

315

0 X

120

014

400

SFB6

1484

1034

775

SAR1

039S

S103

9Y10

120

2123

650

38,2

5SC

R238

538

500

223

050

039

00SF

RH3

150

X 1

200

1440

0SF

B614

8410

3492

8

SAR1

551S

S155

1S15

126

3130

910

50,4

3SC

R247

547

500

223

050

035

20SF

RH3

150

X 1

200

1440

0SF

B614

8410

3410

28

SAR2

059V

V205

9Y20

174

3736

710

58,4

8SC

V272

072

000

240

063

068

20SF

RH4

150

X 1

900

3040

0SF

B721

5410

9696

5

SAR2

571V

V257

1Y25

184

4544

540

70,9

7SC

V272

072

000

240

063

068

20SF

RH4

150

X 1

900

3040

0SF

B721

5410

9696

5

SAR3

084V

V308

4Y30

187

5353

000

83,8

1SC

V285

085

000

240

063

060

60SF

RH4

150

X 1

900

3040

0SF

B721

5410

9610

65

SAR3

5106

ZZ3

5106

Y35

223

6163

410

106,

16SC

V285

085

000

240

063

060

60SF

RH4

150

X 1

900

3040

0SF

B721

5410

9610

65

Low

Tem

p R4

04a

SST

- 25

C

SAR1

59B

B159

Y1,

538

5,3

2320

8,96

SCS1

5858

001

230

350

810

SFRH

115

0 X

400

540

0SF

B364

997

451

9

SAR2

13D

D21

3Y2

456,

835

5013

,84

SCT1

8989

001

230

400

810

SFRH

115

0 X

400

540

0SF

B364

997

462

0

SAR3

18D

D31

8Y3

499,

648

5017

,83

SCT1

120

1200

01

230

400

1080

SFRH

215

0 X

800

940

0SF

B464

997

462

0

SAR4

24F

F424

Y4

7410

,965

8023

,6SC

S215

015

000

223

035

015

60SF

RH2

150

X 8

009

400

SFB4

1052

914

723

SAR5

28Q

Q52

8Y5

7612

,274

3027

,31

SCS2

150

1500

02

230

350

1560

SFRH

215

0 X

800

940

0SF

B410

5291

451

9

SAR7

33S

S733

Y7,

511

717

,588

0032

,8SC

T217

017

000

223

040

029

60SF

RH3

150

X 1

200

1440

0SF

B512

6991

472

3

SAR7

39S

S739

Y7,

511

717

1082

038

,25

SCT2

215

2150

02

230

400

2780

SFRH

315

0 X

120

014

400

SFB5

1269

914

723

SAR1

051S

S105

1Y10

120

2114

080

50,4

3SC

T225

525

500

223

040

026

00SF

RH3

150

X 1

200

1440

0SF

B512

6991

472

3

SAR1

559V

V155

9Y15

170

3115

700

58,4

8SC

R227

527

500

223

050

037

30SF

RH3

150

X 1

200

1440

0SF

B614

8410

3477

6

SAR1

571V

V157

1Y15

170

3119

380

70,7

7SC

R238

538

500

223

050

039

00SF

RH3

150

X 1

200

1440

0SF

B614

8410

3492

8

SAR2

084V

V208

4Y20

180

3722

500

83,8

1SC

R247

547

500

223

050

035

20SF

RH3

150

X 1

200

1440

0SF

B614

8410

3410

28

SAR2

5106

ZZ2

5106

Y25

220

4529

350

106,

16SC

V272

072

000

240

063

068

20SF

RH4

150

X 1

900

1440

0SF

B721

5410

9696

5

SAR3

0126

ZZ3

0126

Y30

229

5335

020

125,

72SC

V285

085

000

240

063

060

60SF

RH4

150

X 1

900

1440

0SF

B721

5410

9610

65

SAR4

0154

ZZ4

0145

Y40

240

7541

660

154,

38SC

V285

085

000

240

063

060

60SF

RH4

150

X 1

900

1440

0SF

B721

5410

9610

65

Medium Temp R404aLow Temp R404a

TD229

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

BASES & CONDENSERS - SCS / SCT / SCR

SCS 2_ _

SCT 2_ _

SCR 2275

SCT 1_ _

TD230

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

BASES & CONDENSERS - SCR / SCV

SCR 2385

SCV 2720

SCV 2850

SCR 2475

TD231

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

CONDENSING UNIT CAPACITY TABLES

Realcold Hermetic Condensing UnitsModel Number

5 0 -5 -10 -15 -20 -25 -30 -35 -40

Medium Temp R404a

RMTZ100 capacity 2450 2117 1791 1495 1222 983 - - - -

input power 1092 996 909 832 765 708 - - - -

RMTZ112 capacity 3138 2669 2231 1825 1456 1123 828 - - -

input power 1335 1226 1116 1004 890 775 658 - - -

RMTZ125 capacity 3819 3256 2728 2246 1820 1464 - - - -

input power 1429 1310 1196 1103 1016 939 - - - -

RMTZ150 capacity 4848 4167 3512 2893 2324 1817 - - - -

input power 2035 1856 1698 1563 1454 1359 - - - -

RMTZ200 capacity 5251 4422 3663 2973 2349 1790 - - - -

input power 2331 2112 1908 1715 1528 1335 - - - -

RMTZ250 capacity 7153 6053 5046 4115 3245 2421 - - - -

input power 2958 2704 2454 2206 1951 1681 - - - -

Medium Temp R404a 5 0 -5 -10 -15 -20 -25 -30 -35 -40

RMTXZ250 capacity 7108 5980 4967 4043 3221 2490 - - - -

input power 2866 2595 2344 2107 1880 1656 - - - -

RMTXZ300 capacity 9145 7716 6422 5256 4214 3289 - - - -

input power 3821 3464 3134 2827 2536 2258 - - - -

RMTXZ450 capacity 10698 9370 7724 6223 4878 3693 - - - -

input power 4708 4229 3755 3313 2886 2471 - - - -

RMTXZ500 capacity 13823 11435 9306 7428 5789 4378 - - - -

input power 5223 4677 4174 3702 3254 2817 - - - -

RMTXZ600 capacity 15526 13120 10931 8961 7193 5639 - - - -

input power 6703 5961 5284 4662 4085 3548 - - - -

RMTXZ900 capacity 21396 18740 15448 12446 9756 7386 - - - -

input power 9416 8458 7510 6626 5772 4942 - - - -

RMTXZ1000 capacity 27646 22870 18612 14856 11578 8756 - - - -

input power 10446 9354 8348 7404 6508 5634 - - - -

RMTXZ1200 capacity 31052 26240 21862 17922 14386 11278 - - - -

input power 13406 11922 10568 9324 8170 7096 - - - -

Medium Temp R134a 5 0 -5 -10 -15 -20 -25 -30 -35 -40

RMTY100 capacity 2933 2448 1996 1588 1230 930 - - - -

input power 1081 965 855 746 633 512 - - - -

RMTY150 capacity 4322 3568 2837 2136 1472 854 - - - -

input power 1594 1401 1223 1050 877 697 - - - -

RMTY200 capacity 5550 4613 3739 2957 2277 1736 - - - -

input power 2152 1881 1652 1452 1270 1095 - - - -

Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.

TD232

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

CONDENSING UNIT CAPACITY TABLES

Model Number

5 0 -5 -10 -15 -20 -25 -30 -35 -40

Low Temp R404a

RLT100 capacity - - - 1762 1474 1210 979 789 644 -

input power - - - 1200 1068 959 870 801 749 -

RLTZ150 capacity - - - 2533 2112 1732 1402 1125 907 -

input power - - - 1584 1425 1290 1181 1095 1028 -

RLTZ200 capacity - - - 3544 2913 2336 1817 1359 958 -

input power - - - 2489 2180 1913 1680 1480 1315 -

RLTZ300 capacity - - - 5176 4257 3431 2720 2145 1717 1443

input power - - - 2873 2535 2249 2014 1823 1670 1550

RLTZ400 capacity - - - 7255 5955 4769 3723 2853 2181 1718

input power - - - 4331 3764 3280 2871 2528 2241 1997

RLTZ500 capacity - - - 8945 7389 5973 4737 3717 2938 2423

input power - - - 5130 4480 3939 3498 3153 2897 2687

RLTZ600 capacity - - - 10352 8514 6862 5440 4290 3434 -

input power - - - 5746 5070 4498 4028 3646 3340 -

RLTZ800 capacity - - - 14510 11910 9538 7446 5706 4362 3436

input power - - - 8662 7528 6560 5742 5056 4482 3994

RLTZ1000 capacity - - - 17890 14778 11946 9474 7434 5876 4846

input power - - - 10260 8960 7878 6996 6306 5794 5374

Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.

TD233

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

SEMI-HERMETIC CONDENSING UNIT CAPACITY TABLES

Model Number

5 0 -5 -10 -15 -20 -25 -30 -35 -40

Medium Temp R404a

SAR16A capacity 4.46 3.84 3.27 2.75 2.28 1.86 1.48 1.16 0,87 -

input power 1.82 1.61 1.42 1.26 1.10 0.97 0.85 0.75 0,65 -

SAR157 capacity 5.60 4.82 4.10 3.46 2.86 2.33 1.86 1.46 1,10 -

input power 2.08 1.88 1.67 1.50 1.33 1.18 1.05 0.94 0,81 -

SAR210 capacity 8.34 7.17 6.09 5.12 4.24 3.46 2.77 2.18 - -

input power 3.08 2.85 2.62 2.41 2.21 2.01 1.82 1.64 - -

SAR313 capacity 11.15 9.59 8.15 6.86 5.68 4.64 3.71 2.92 - -

input power 4.42 3.99 3.60 3.25 2.91 2.60 2.31 2.04 - -

SAR416 capacity 13.61 11.73 9.99 8.44 7.02 5.76 4.64 3.68 - -

input power 5.13 4.64 4.19 3.79 3.40 3.04 2.70 2.39 - -

SAR519 capacity 16.19 13.95 11.89 10.06 8.37 6.89 5.57 4.43 - -

input power 5.71 5.22 4.75 4.32 3.91 3.53 3.16 2.82 - -

SAR524 capacity 20.06 17.32 14.79 12.53 10.45 8.62 6.99 5.59 - -

input power 7.42 6.69 6.01 5.44 4.90 4.41 3.94 3.54 - -

SAR728 capacity 23.39 20.11 17.11 14.44 12.01 9.86 7.96 6.33 - -

input power 7.96 7.33 6.71 6.14 5.55 4.99 4.44 3.94 - -

SAR733 capacity 28.45 24.40 20.69 17.41 14.42 11.78 9.45 7.47 - -

input power 9.50 8.69 7.89 7.17 6.44 5.77 5.11 4.51 - -

SAR1039 capacity 32.06 27.69 23.65 20.05 16.73 13.80 11.19 8.95 - -

input power 11.45 10.38 9.36 8.45 7.57 6.76 5.98 5.29 - -

SAR1551 capacity 42.19 36.31 30.91 26.10 21.69 17.79 14.32 11.36 - -

input power 14.54 13.18 11.85 10.66 9.51 8.48 7.49 6.60 - -

SAR2059 capacity 50.21 43.17 36.71 30.96 25.69 21.03 16.90 13.38 - -

input power 16.80 15.14 13.56 12.17 10.88 9.75 8.64 7.62 - -

SAR2571 capacity 61.31 52.54 44.54 37.48 31.04 25.38 20.36 16.11 - -

input power 20.13 18.31 16.53 14.89 13.27 11.78 10.36 9.08 - -

SAR3084 capacity 72.67 62.38 53.00 44.69 37.12 30.45 24.55 19.52 - -

input power 24.88 22.53 20.25 18.16 16.09 14.19 12.38 10.78 - -

SAR35106 capacity 85.87 74.21 63.41 53.70 44.76 36.80 29.69 23.57 - -

input power 32.91 29.49 26.32 23.47 20.69 18.16 15.79 13.74 - -

Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.

TD234

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

SEMI-HERMETIC CONDENSING UNIT CAPACITY TABLES

Model Number

5 0 -5 -10 -15 -20 -25 -30 -35 -40

Low Temp R404a

SAR159 capacity - 5.66 4.88 4.16 3.49 2.87 2.32 1.83 1.39 -

input power - 2.92 2.53 2.22 1.94 1.68 1.45 1.25 1.07 -

SAR213 capacity - - 7.45 6.34 5.32 4.39 3.55 2.82 2.16 -

input power - - 4.13 3.58 3.10 2.70 2.33 2.00 1.70 -

SAR318 capacity - - 10.00 8.54 7.18 5.95 4.85 3.90 3.04 2.33

input power - - 5.01 4.41 3.89 3.44 3.03 2.67 2.34 2.04

SAR424 capacity - - - 11.37 9.62 8.02 6.58 5.32 4.20 3.24

input power - - - 5.99 5.28 4.67 4.11 3.62 3.16 2.75

SAR728 capacity 20.30 17.72 15.28 13.06 10.98 9.11 7.43 5.96 - -

input power 8.80 7.95 7.17 6.47 5.78 5.14 4.53 3.99 - -

SAR733 capacity 24.56 21.40 18.41 15.69 13.16 10.87 8.80 7.01 - -

input power 10.68 9.54 8.50 7.60 6.73 5.95 5.22 4.56 - -

SAR739 capacity - - - 18.85 15.89 13.22 10.82 8.74 6.89 5.31

input power - - - 9.28 8.21 7.27 6.38 5.59 4.85 4.18

SAR1051 capacity - - - 24.68 20.74 17.24 14.08 11.33 8.89 6.81

input power - - - 12.26 10.69 9.36 8.13 7.06 6.05 5.16

SAR1559 capacity - - 31.50 27.12 22.97 19.17 15.70 12.64 9.90 7.56

input power - - 16.21 14.18 12.28 10.63 9.13 7.86 6.69 5.67

SAR1571 capacity - - - 34.09 28.62 23.77 19.38 15.54 12.13 9.21

input power - - - 17.26 14.97 13.01 11.18 9.60 8.15 6.88

SAR2084 capacity - - - 38.36 32.51 27.29 22.50 18.28 14.48 11.23

input power - - - 20.77 17.88 15.41 13.20 11.35 9.81 8.43

SAR25106 capacity - - - 52.00 43.56 36.08 29.35 23.52 18.34 13.94

input power - - - 25.12 21.89 19.13 16.53 14.22 12.07 10.17

SAR30126 capacity - - - - 51.87 43.01 35.02 28.10 21.94 16.71

input power - - - - 26.86 23.48 20.29 17.43 14.71 12.26

Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.

TD235

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

STANDARD AIR COOLED CONDENSERS

Horizontal DischargeModel Number

R404aCapacityW @ 15K

Fans Dimensions (mm) Connections (mm)

Number Diameter Voltage Watts Total

Air Flow L/S

L H D Inlet Outlet

SCT168 6659 1 400 230V 150 1310 630 530 205 16 10

SCT189 8717 1 400 230V 150 1230 630 530 205 16 10

SCT1120 11951 1 400 230V 150 1080 630 530 205 16 10

SCS2120 11657 2 350 230V 210 1620 980 430 205 16 10

SCS2150 14406 2 350 230V 210 1560 980 430 205 22 12,5

SCT2170 16758 2 400 230V 300 2960 1200 635 205 22 12,5

SCT2215 20977 2 400 230V 300 2780 1200 635 205 22 12,5

SCT2255 25093 2 400 230V 300 2600 1200 635 205 22 12,5

SCR2275 27500 2 500 230V 780 3730 1400 635 285 28 16

SCR2385 38500 2 500 230V 780 3900 1400 840 285 28 16

SCR2475 47250 2 500 230V 780 3520 1400 940 255 28 16

SCV2720 72030 2 630 400V 2076 6820 2050 840 285 35 22

SCV2850 84481 2 630 400V 2076 6060 2050 940 285 35 22

Vertical DischargeModel Number

R404aCapacitykW @ 15kTD

Fans Dimensions (mm) Connections (mm)

Number Diameter Voltage Watts Amps 3Ph

Air Flow m³/s

L H D Inlet Outlet

SCV2100 100 2 630 400V 3,6 6600 2064 1210 1243 42 35

SCV2115 115 2 630 400V 3,6 6900 2257 1210 1243 42 35

SCV3145 144 3 630 400V 5,4 10400 3064 1210 1243 54 42

SCV3160 162 3 630 400V 5,4 9900 3064 1210 1243 54 42

SCV4195 196 4 630 400V 7,2 12800 3664 1210 1243 65 54

SCV5230 230 5 630 400V 9,0 17500 4564 1210 1243 65 54

SCV4200 200 4 630 400V 7,2 13200 2064 1210 1243*2 42*2 35*2

SCV6280 288 6 630 400V 10,8 20800 3064 1210 1243*2 42*2 35*2

SCV6320 324 6 630 400V 10,8 19800 3064 1210 1243*2 54*2 42*2

SCV8390 392 8 630 400V 14,4 15600 3664 1210 1243*2 62*2 54*2

SCV10460 460 10 630 400V 18,0 35000 4564 1210 1243*2 65*2 54*2

Note: Condenser ratings @ 30°C & 101.325kPa ambient air.Optional: Ziehl-abegg 500 mm & 630 mm 2 speed plate axial fans, EC Variable Speed.

TD236

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

AIR COOLED CONDENSERS - SCT / SCR / SCV

SCT1_ _

SCV 2850

SCV 2720

SCR2475

SCR2385

SCT2_ _

TD237

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

AIR COOLED CONDENSERS - SCV

SCV2100 SCV2125

SCV3_ _ _ SCV4200

SCV5230

TD238

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

EVAPORATOR DATAM

ediu

m T

emp

Real

cold

Stoc

k N

o.N

ew M

odel

Cap

acity

13

4A@

6K

TD

404A

Air

Flow

(m

³/s)

Air

Thro

w

(m)

Fan

Stoc

k N

umbe

rN

o Fa

nsFa

n D

iam

eter

Fan

pow

er

(Am

p ea

)D

/F E

lem

ent

Num

ber

Def

rost

(k

W)

D/F

Tra

y N

umbe

rD

imen

sion

sC

onne

ctio

nsD

rain

(B

SP)

Wei

ght

(Kg)

LW

HIn

let

Out

let

W46

00H

CT-

251-

2R41

841

00.

122.

5-

125

00.

25n/

a-

n/a

425

450

175

9.5

9.5

12.7

5.5

W46

03H

CT-

251-

4R99

097

00.

133.

0-

125

00.

42n/

a-

n/a

425

450

175

9.5

9.5

12.7

11W

4605

HC

T-25

2_2R

1235

1210

0.33

4.0

-2

250

0.42

n/a

-n/

a75

045

017

59.

59.

512

.716

W46

07H

CT-

252-

4R18

5718

200.

293.

5-

225

00.

42n/

a-

n/a

750

450

175

9.5

12.5

2020

W46

09H

CT-

254-

3R24

8024

300.

33.

5-

425

00.

042

n/a

-n/

a14

0045

017

59.

512

.520

30W

5500

TM14

041

6540

820.

8-

-1

400

0.78

n/a

-n/

a12

2484

535

512

.722

.320

38W

5502

TM27

071

4370

001.

6-

-2

400

0.78

n/a

-n/

a17

0585

036

012

.722

.320

59W

5504

TM31

0010

204

1000

02.

4-

-3

400

0.78

n/a

-n/

a22

0585

036

012

.728

.120

85W

5508

TM31

4014

286

1400

03.

3-

-4

400

0.78

n/a

-n/

a27

0585

036

012

.728

.120

121

W50

00N

M11

414

0013

720.

739.

0R0

930

130

00.

68n/

a-

n/a

770

400

395

12.7

15.9

2017

W50

02N

M11

716

9016

560.

688.

5R0

930

130

00.

68n/

a-

n/a

770

400

395

12.7

15.9

2018

W50

04N

M12

120

9020

480.

648.

0R0

930

130

00.

68n/

a-

n/a

770

400

395

12.7

15.9

2019

W50

06N

M12

423

7023

230.

738.

0R0

930

130

00.

68n/

a-

n/a

975

400

395

12.7

15.9

2021

W50

08N

M12

727

1026

560.

77.

5R0

930

130

00.

68n/

a-

n/a

975

400

395

12.7

15.9

2023

W50

10N

M23

232

0031

361.

459.

0R0

930

230

00.

68n/

a-

n/a

1270

400

395

12.7

15.9

2025

W50

12N

M24

039

5038

711.

368.

5R0

930

230

00.

68n/

a-

n/a

1270

400

395

12.7

15.9

2027

W50

14N

M24

545

2044

301.

288.

0R0

930

230

00.

68n/

a-

n/a

1270

400

395

12.7

22.3

2029

W50

16N

M25

454

5053

412.

058.

0R0

930

330

00.

68n/

a-

n/a

1770

400

395

12.7

22.3

2044

W50

18N

M46

464

0062

722.

919.

0R0

930

430

00.

68n/

a-

n/a

2270

400

395

12.7

22.3

2050

W50

20N

M37

474

0072

521.

937.

5R0

930

330

00.

68n/

a-

n/a

1770

400

395

12.7

22.3

2047

W50

22N

M47

978

9577

372.

738.

0R0

930

430

00.

68n/

a-

n/a

2270

400

395

15.9

28.1

2058

W50

24SM

271

7102

6960

1.76

17.0

R093

52

350

0.58

n/a

-n/

a14

8348

251

012

.722

.320

48W

5026

SM38

685

9984

272.

718

.0R0

935

335

00.

58n/

a-

n/a

2233

482

510

15.9

2920

71W

5028

SM31

0510

653

1044

02.

6417

.0R0

935

335

00.

58n/

a-

n/a

2233

482

510

15.9

3520

75W

5030

SM31

2512

434

1218

52.

5816

.0R0

935

335

00.

58n/

a-

n/a

2233

482

510

15.9

3520

79W

5032

SM41

4014

204

1392

03.

5217

.0R0

935

435

00.

58n/

a-

n/a

2731

482

510

15.9

3520

92W

5034

SM41

6516

574

1624

33.

4416

.0R0

935

435

00.

58n/

a-

n/a

2731

482

510

15.9

3520

98W

5036

SM52

1021

179

2034

04.

2819

.0R0

935

535

00.

58n/

a-

n/a

3223

482

510

15.9

3540

121

W52

00SM

271P

7102

6960

1.76

18.0

R093

52

350

0.58

W72

401.

5n/

a14

8348

251

012

.722

.320

48W

5202

SM38

6P85

9984

272.

720

.0R0

935

335

00.

58W

7242

2.4

n/a

2233

482

510

15.9

2920

71W

5204

SM31

05P

1065

310

440

2.64

19.0

R093

53

350

0.58

W72

422.

4n/

a22

3348

251

015

.935

2075

W52

06SM

3125

P12

434

1218

52.

5818

.0R0

935

335

00.

58W

7242

2.4

n/a

2233

482

510

15.9

3520

79W

5208

SM41

40P

1420

413

920

3.52

17.0

R093

54

350

0.58

W72

443

n/a

2731

482

510

15.9

3540

92W

5210

SM41

65P

1657

416

243

3.44

16.0

R093

54

350

0.58

W72

443

n/a

2731

482

510

15.9

3540

98W

5212

SM52

10P

2117

9-

4.28

19.0

R093

55

350

0.58

W72

463

n/a

3223

482

510

15.9

3540

121

W52

30RM

2140

1400

013

333

4.1

24.0

R095

02

500

1.85

-4.

5n/

a22

1067

080

516

2940

132

W52

32RM

3185

1840

017

524

5.0

24.0

R095

03

500

1.85

-4.

5n/

a22

4068

510

7516

3540

173

W52

34RM

3210

2060

019

619

5.4

24.0

R095

03

500

1.85

-4.

5n/

a27

4068

510

7516

3540

196

W52

36RM

3230

2310

022

000

5.1

24.0

R095

03

500

1.85

-5.

4n/

a27

4068

510

7516

3540

198

W52

38RM

3250

2520

024

000

6.6

24.0

R095

04

500

1.85

-4.

5n/

a27

4068

510

7516

3540

242

W52

40RM

4280

2810

026

762

6.4

24.0

R095

04

500

1.85

-5.

4n/

a27

4068

510

7516

3540

242

W52

42VM

2310

3100

029

524

8.3

25.0

R096

32

630

1.8

-5.

4n/

a22

4077

513

0516

3540

280

W52

44VM

2340

3440

032

762

7.0

26.0

R096

32

630

1.8

-4.

8n/

a22

4077

513

0516

4140

340

W52

46VM

3400

4000

038

095

10.4

26.0

R096

33

630

1.8

-6.

0n/

a32

4077

513

0516

4140

420

W52

48VM

3450

4510

042

952

10.2

26.0

R096

33

630

1.8

-7.

2n/

a32

4077

513

0516

X 2

35 X

240

420

W52

50VM

3480

4830

046

000

10.4

26.0

R096

33

630

1.8

-7.

2n/

a36

0077

513

0516

X 2

35 X

240

430

W52

52VM

4520

5200

049

524

13.0

28.0

R096

34

630

1.8

-8.

0n/

a36

0077

513

0516

X 2

35 X

240

430

W52

54VM

4560

5600

053

333

13.6

28.0

R096

34

630

1.8

-8.

8n/

a38

9077

513

0516

X 2

35 X

240

510

TD239

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

EVAPORATOR DATA

Low

Tem

pRe

alco

ldSt

ock

No.

New

Mod

elC

apac

ity

R404

a@

6K

TD

R22

Air

Flow

(m

³/s)

Air

Thro

w

(m)

Fan

Stoc

k N

umbe

rN

o Fa

nsFa

n D

iam

eter

Fan

pow

er

(Am

p ea

)St

ock

No

Def

rost

(k

W)

D/F

Tra

y N

umbe

rW

atts

Dim

ensi

ons

Con

nect

ions

Dra

in

(BSP

)W

eigh

t (K

g)L

WH

Inle

tO

utle

t

W46

04H

CT-

252-

2RE

830

-0.

133.

0-

225

00.

42-

360

n/a

-75

045

017

59.

59.

520

11

W46

06H

CT-

252-

3RE

1016

-0.

334.

0-

225

00.

42-

360

n/a

-75

045

017

59.

512

.520

16

W46

08H

CT-

253-

3RE

1528

-0.

293.

5-

325

00.

42-

540

n/a

-10

7545

017

59.

512

.520

20

W46

10H

CT-

254-

3RE

2041

--

--

425

00.

42-

720

n/a

-14

0045

017

59.

512

.5

W50

50N

L112

1210

1184

0.73

9.0

R093

01

300

0.68

n/a

1.4

W72

0014

0077

040

039

512

.715

.920

17

W50

52N

L115

1455

1426

0.68

8.5

R093

01

300

0.68

n/a

1.4

W72

0014

0077

040

039

512

.715

.920

18

W50

54N

L118

1800

1763

0.64

8.0

R093

01

300

0.68

n/a

1.4

W72

0014

0077

040

039

512

.715

.920

19

W50

56N

L120

2040

1998

0.73

8.0

R093

01

300

0.68

n/a

1.4

W72

0218

0097

540

039

512

.715

.920

21

W50

58N

L123

2330

2288

0.7

7.5

R093

01

300

0.68

n/a

1.4

W72

0218

0097

540

039

512

.715

.920

23

W50

60N

L228

2760

2706

1.45

9.0

R093

02

300

0.68

n/a

2.4

W72

0424

0012

7040

039

512

.715

.920

29

W50

62N

L234

3400

3330

1.36

8.5

R093

02

300

0.68

n/a

2.4

W72

0424

0012

7040

039

512

.715

.920

31

W50

64N

L239

3890

3815

1.28

8.0

R093

02

300

0.68

n/a

2.4

W72

0424

0012

7040

039

512

.722

.320

33

W50

66N

L347

4695

4601

2.05

8.0

R093

03

300

0.68

n/a

3.6

W72

0836

0017

7040

039

512

.722

.320

44

W50

68N

L455

5520

5413

2.91

9.0

R093

04

300

0.68

n/a

4.8

W72

1048

0022

7040

039

512

.722

.320

50

W50

70N

L464

6375

6375

1.93

7.5

R093

03

300

0.68

n/a

3.6

W72

0836

0017

7040

039

512

.722

.320

47

W50

72N

L468

6800

6668

2.73

8.0

R093

04

300

0.68

n/a

4.8

W72

1048

0022

7040

039

515

.928

.120

58

W50

74SL

261

6119

5997

1.76

17.0

R093

52

350

0.58

W72

403.

5W

7206

2000

1483

482

510

12.7

22.3

2048

W50

76SL

374

7409

7261

2.7

18.0

R093

53

350

0.58

W72

426.

0W

7210

4800

2233

482

510

15.9

2920

71

W50

78SL

392

9179

8995

2.64

17.0

R093

53

350

0.58

W72

427.

2W

7210

4800

2233

482

510

15.9

3520

75

W50

80SL

3110

1071

310

499

2.58

16.0

R093

53

350

0.58

W72

427.

2W

7210

4800

2233

482

510

15.9

3520

79

W50

82SL

4120

1223

911

994

3.52

17.0

R093

54

350

0.58

W72

447.

7W

7212

3200

2723

482

510

15.9

3540

92

W50

84SL

4145

1428

213

996

3.44

16.0

R093

54

350

0.58

W72

447.

7W

7212

3200

2723

482

510

15.9

3540

98

W50

86SM

521

0P17

836

1747

94.

2819

.0R0

935

535

00.

58W

7246

9.0

W72

2418

0032

2348

251

015

.935

4012

1

W52

60RL

3160

1620

015

600

4.6

24.0

R050

03

500

1.85

W72

409.

0W

7222

3600

2740

670

805

1635

4017

3

W52

62RL

3185

1850

017

800

4.8

24.0

R050

03

500

1.85

W72

4210

.8W

7224

3600

3240

670

805

1635

4019

6

W52

64RL

3200

1970

018

950

4.8

24.0

R050

03

500

1.85

W72

4210

.8W

7222

3600

2740

685

1075

1635

4019

8

W52

66RL

4220

2170

020

865

6.8

25.0

R050

04

500

1.85

W72

4412

.6W

7224

3600

3240

685

1075

1635

4019

8

W52

68RL

4250

2470

023

750

6.4

25.0

R050

04

500

1.85

W72

4414

.4W

7224

3600

3240

685

1075

1635

4024

2

W52

70VL

2280

2800

026

900

7.0

25.0

R063

02

630

1.8

W72

4610

.8W

7220

3600

2240

775

1305

1635

4024

2

W52

72VL

2300

3000

028

850

7.1

25.0

R063

02

630

1.8

W72

4413

.5W

7222

3600

2740

775

1305

1641

4029

0

W52

74VL

3350

3500

033

500

10.4

26.0

R063

03

630

1.8

W72

4614

.4W

7224

3600

3240

775

1305

1641

4034

5

W52

76VL

3400

4000

038

500

10.2

26.0

R063

03

630

1.8

W72

4616

.2W

7224

3600

3240

775

1305

16 X

235

X 2

4034

5

W52

78VL

4450

4500

043

269

12.0

27.0

R063

04

630

1.8

W72

4818

.0W

7226

6400

3600

775

1305

16 X

235

X 2

4043

0

W52

80VL

4500

5000

048

077

13.2

27.0

R063

04

630

1.8

W72

5019

.8W

7288

6400

3890

775

1305

16 X

235

X 2

4043

0

* O

ptio

nal 2

spe

ed Z

iehl

pla

te a

xial

or E

C fa

ns a

vaila

ble

for R

and

V e

vaps

ser

ies

on re

ques

t.

TD240

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

COOLING UNITS

HCT SERIES

NDD DUAL DISCHARGE BLOWER COILS

RDD DUAL DISCHARGE T-FLOW SERIES

RONDO SERIES

TD241

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

COOLING UNITS - N / S SERIES

N_1_ _ N_1_ _ N_2_ _

N_3_ _ N_4_ _

S_2_ _ S_3_ _

S_4_ _ S_5_ _

TD242

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

HCT RANGE UNIT COOLERS

HCT Range Unit Coolers 250 mm Fans - Technical DataModel 251-2R 251-3R 251-4R 252-2R 252-3R 252-4R 253-2R 253-3R 253-4R 254-2R 254-3R 254-4R

Fin Spacing 6F (4.2 mm)

Nominal Capacity R22

kW @ ITD = 6K and Te = -5°C

0.41 0.55 0.63 0.97 1.21 1.33 1.49 1.82 2.00 1.99 2.43 2.67

Coil surface area m² 1.0 1.5 2.0 2.0 3.0 4.0 3.0 4.5 6.0 4.0 6.0 8.0

Air flow - frost free m³/s 0.14 0.12 0.11 0.28 0.24 0.22 0.43 0.36 0.32 0.57 0.49 0.43

Face velocity m/s 2.91 2.49 2.22 2.91 2.49 2.22 2.91 2.49 2.22 2.91 2.49 2.22

Mass Kg 5.2 5.5 5.7 7.8 8.4 8.9 10.9 11.7 12.4 14.0 15.0 16.0

General Data

Tube internal volume litre 0.35 0.53 0.71 0.62 0.94 1.25 0.89 1.34 1.79 1.16 1.75 2.33

Air throw m 10 9 8 10 9 8 10 9 8 10 9 8

Liquid connection inch 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4”

Suction connection inch 3/8” 3/8” 3/8” 3/8” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”

Elect. defrost 230V kW 0.12 0.18 0.24 0.24 0.36 0.48 0.36 0.54 0.72 0.48 0.72 0.96

Physical Data

• Models: HCT 251 2R/3R/4R & 252 2R are suitable for internally equalized expansion valves

• Models: 252 3R and above are suitable for externally equalized expansion valves

• Drain: 3/4” BSPM Fitting

• Fan: 250 mm diameter, 230/ 1/ 50Hz, 42 W x 0.42 A each

TD243

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

RONDO RANGE UNIT COOLERS

Rondo Range Unit Coolers 250 mm & 300 mm Fans - Technical DataModel 140-A 240-A 340-A 440-A 400-A 500-A 700-A 900-A 1100-A 1300-A

Fin Spacing 6F (4.2 mm)

Nominal Capacity R22

kW @ ITD = 6K and Te = -5°C

0.63 0.80 0.95 1.08 1.19 1.66 2.06 3.38 4.04 4.64

Coil surface area m² 1.98 2.97 3.71 4.45 4.15 6.23 8.3 10.22 12.77 17.03

Air flow - frost free m³/s 0.21 0.19 0.21 0.22 0.29 0.37 0.43 0.92 1.05 0.94

Face velocity m/s 2.22 1.96 1.76 1.57 2.25 1.92 1.65 2.88 2.64 2.36

Mass Kg 4.00 4.50 5.00 5.50 7.20 8.30 9.40 14.00 15.40 17.40

General Data

Tube internal volume litre 0.56 0.84 1.05 1.26 1.15 1.72 2.3 2.80 3.5 4.66

Fans no x dia 1 x 250 1 x 250 1 x 250 1 x 250 2 x 250 2 x 250 2 x 250 2 x 300 2 x 300 2 x 300

Liquid connection inch 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”

Suction connection inch 3/8” 3/8” 3/8” 3/8” 1/2” 1/2” 5/8” 5/8” 3/4” 3/4”

Fan WiringDiameter mm Voltage V Frequency Hz RPM Power W Amperage A

Square shaded-pole motor (standard)

250 230 50 1300 16/60 0.42

300 230 50 1300 34/110 0.75

External rotor motor (option)

300 230 50 1400 68 0.3

TD244

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

HDD RANGE DUAL DISCHARGE COOLERS

HDD Range Dual Discharge Coolers 250 mm Fans - Technical DataModel 251-A-2R 251-A-3R 251-A-4R 252-A-2R 252-A-3R 252-A-4R

Fin Spacing 6F (4.2 mm)

Nominal Capacity R22

kW @ ITD = 6K and Te = -5°C

0.78 0.95 1.03 1.67 2.03 2.18

Coil surface area m² 1.76 2.63 3.52 3.51 5.27 7.02

Air flow - frost free m³/s 0.19 0.16 0.15 0.39 0.33 0.29

Face velocity m/s 2.22 1.89 1.69 2.22 1.89 1.69

Mass Kg 5.70 6.20 6.80 9.50 10.50 11.50

General Data

Tube internal volume litre 0.53 0.79 1.05 1.06 1.58 2.1

Air throw m 2.7 2.3 2.1 2.7 2.3 2.1

Fans no x dia 1 x 250 1 x 250 1 x 250 2 x 250 2 x 250 2 x 250

Liquid connection inch 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”

Suction connection inch 3/8” 3/8” 3/8” 1/2” 5/8” 5/8”

Elect. defrost 230V kW 0.45 0.45 0.45 0.90 0.90 0.90

Physical Data

• Models: 201 2R and above are suitable for externally equalized expansion valves

• Drain: 1/2” Copper tube

• Fan: 250 mm diameter, 230/ 1/ 50Hz, 16 W x 0.42 A each

TD245

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

HSR RANGE UNIT COOLERS

HSR Range Unit Coolers 350 mm Fans - Technical DataModel 351-4R 351-6R 352-4R 352-6R 353-4R 353-6R 354-4R 354-6R

Fin Spacing 6F (4.2 mm)

Nominal Capacity R22

kW @ ITD = 6K and Te = -5°C

3.24 3.82 6.54 7.70 9.83 11.58 13.14 15.44

Coil surface area m² 16 24 32 48 48 72 64 97

Air flow - frost free m³/s 0.71 0.65 1.42 1.30 2.13 1.95 2.84 2.60

Face velocity m/s 2.67 2.44 2.67 2.44 2.67 2.44 2.67 2.44

Mass Kg 23 27 38 44 51 61 65 78

Fin Spacing 4F (6.35 mm)

Nominal Capacity R22

kW @ ITD = 6K and Te = -5°C

2.66 3.33 5.33 6.70 8.04 10.07 10.73 13.45

Coil surface area m² 11 17 22 33 33 50 44 67

Air flow - frost free m³/s 0.75 0.70 1.50 1.40 2.25 2.10 3.00 2.80

Face velocity m/s 2.79 2.61 2.79 2.61 2.79 2.61 2.79 2.61

Mass Kg 23 26 37 43 49 58 63 75

General Data

Tube internal volume litre 3.44 5.16 6.26 9.38 9.07 13.61 11.59 17.83

Air throw m 14 14 15 15 16 16 17 17

Liquid connection inch 1/2” 1/2” 1/2” 1/2” 5/8” 5/8” 5/8” 5/8”

Suction connection inch 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8” 1 3/8” 1 3/8” 1 3/8”

Elect. defrost 230V kW 2.0 2.5 4.0 5.0 6.0 7.5 8.0 10.0

Physical Data

• Models: 351 4R and above are suitable for externally equalized expansion valves

• Drain: 3/4” BSPM Fitting

• Fan: 350mm diameter, 230 /1/50 Hz, 130 W x 0.58 A each

Dimensions (mm) A 350 350 375 375 400 400 500 500

TD246

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

SMALL COOLROOM CAPACITIES

Small Coolroom Capacities

• Typical Coolroom

• Duties for Small Storage Only Rooms

• 30°C ambient

• Coolrooms 100 mm polystyrene walls and ceiling

• Freezers 150 mm polystyrene wals, floor, ceiling

• Internal hieght = 2.4 m

• For other specific applications contact

• Realcold Technical Department +64 (0)9 526 5700

Small Coolroom Capacities - InformationRoom Dimension Medium Temp +2°C Low Temp -18°C

Length (m) Width (m) Volume (m³) Average (W) Heavy (W) Average (W) Heavy (W)

1.8 1.2 3.8 900 1170 1400 1820

1.8 1.8 6.1 1100 1430 1600 2080

2.4 1.8 8.4 1300 1690 1800 2340

2.4 2.4 11.6 1500 1950 2000 2600

3.0 2.4 14.8 1700 2210 2200 2860

3.0 3.0 18.8 2000 2600 2400 3120

3.6 2.4 18.0 2000 2600 2400 3120

3.6 3.0 22.8 2300 2990 2600 3380

3.6 3.6 27.7 2700 3510 2800 3640

4.2 2.4 21.1 2200 2860 2500 3250

4.2 3.0 26.9 2500 3250 2800 3640

4.2 3.6 32.6 3000 3900 3200 4160

4.2 4.2 38.4 3300 4290 3500 4550

4.8 3.6 37.5 3300 4290 3500 4550

4.8 4.2 44.2 4000 5200 4200 5460

4.8 4.8 50.8 4500 5850 4800 6240

6.0 3.6 47.3 4300 5590 4500 5850

6.0 4.2 55.7 4700 6110 5000 6500

6.0 4.8 64.0 5000 6500 5500 7150

6.0 6.0 80.7 5500 7150 6000 7800

TD247

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

REFRIGERATION TERMINOLOGY

Refrigeration Terminology

Temperature

Indicates level of heat energy

1. Centigrade Scale ºC (Celsius)

Absolute Temperature ºK (Kelvin) = ºC + 273º

2. Fahrenheit Scale ºF. Absolute Temperature º (Rankin) = ºF + 460

3. Conversion: ºC = 5/9 x (ºF - 32) ºF = (9/5 x ºC) + 32

Measurement

A British Thermal Unit (BTU) is the heat required to raise or lower the temperature of 1 lb of water 1ºF. 4.19 Kilojoule is the heat required to raise or lower 1 Kg of water 1 K

State of Matter

Solid, liquid and gas

Change of State

The change from one state of matter to another by the addition or the removal of heat at constant temperature.

Sensible Heat

Heat added to or subtracted from a substance without a change of state (only a change in temperature).

Specific Heat

The amount of sensible heat required to raise the temperature of 1 lb (1kg) of a substance 1ºF (1K) or the ratio of the heat capacity of the sub-stance to that of water.

Latent Heat

Quantity of heat added to or removed from a unit weight of a substance during change of state at constant temperature.

(BTU/lb) (kj/kg)

1. Latent Heat of Fusion: Melting of a solid or freezing of a liquid.

2. Latent Heat of Evaporation: Change from a liquid to a gas.

3. Latent Heat of Condensation: Change from a gas to a liquid.

Total Heat (Enthalpy) Heat Capacity

The sum total of sensible and latent heat quantities. BTU/lb (kj/kg), usu-ally referenced to -40º at which point the Total Heat (Enthalpy) is taken as 0 BTU/lb with negative values below -40º. When all heat has been extracted from a substance, it is said to be at Absolute Zero 0ºR (Rankin) or correspondingly 0ºK (Kelvin).

Note: Enthalpy referenced to 0ºF for air.

Pressure

Expressed in Pounds per Square Inch, Gauge; or Absolute Pressure (psig or psia).

1. Atmospheric Pressure: At sea level is 14.7 lbs/sq. inch absolute (deduct approx. 0.5 lbs/sq. inch or 1 inch of mercury for every 1,000 feet increase in elevation above sea level).

2. Gauge Pressure: Is equal to Absolute Pressure less Atmospher-ic Pressure. Thus at 4,000 feet elevation gauge pressure (psig) will be 4 x 0.5 or 2 lbs/sq. inch (psi) higher than at sea level for the same condition.

3. Vacuum: Pressures below atmospheric pressure are measured in inches of mercury (vacuum) (two inches of mercury can be equal to one lb/sq. inch). A perfect vacuum (0 psia) being equal to 29.92 inches of mercury (“Hg) or 760mm, at sea level. Meas-urements are sometimes expressed in microns (1,000,000) mi-crons in a metre).

4. Vapour Pressure: Equilibrium Pressure between a liquid and its saturated vapour. As long as vapour and liquid are both pre-sent, there will be only one vapour pressure for each level of temperature.

5. Gas Pressure: In the absence of liquid, the pressure of a gas is proportional to Absolute gas temperature and to gas density (perfect gas laws).

Saturated Vapour and Liquid

When gas and liquid exist in equilibrium, there will be only one vapour pressure for each level of temperature.

1. Subcooled Liquid: If additional heat is removed from saturated liquid in the absence of vapour, its temperature is reduced at constant pressure and it becomes subcooled.

2. Superheated Gas: If additional heat is added to saturated va-pour in the absence of liquid, it becomes superheated vapour or gas.

Conversion: 1 Ton of Refrigeration = 12,000 BTU/Hr

= 3.517 kW

= 3517 Watts

1 Watt = 3.412 BTU/Hr

1 psi = 6.895 kPa

Refrigeration Cycle Calculations*

1. Refrigerating Effect: (BTU/lb)= Enthalpy of vapour leaving the evaporator minus the enthalpy of liquid ahead of throttling de-vice.

2. Quality: Fraction of liquid flashed at the throttling device to cool the balance of the liquid to evaporator temperature = Enthalpy of liquid ahead of throttling device minus enthalpy of saturated liquid at evaporator temperature divided by the latent heat at evaporator temperature.

3. Refrigerant Flow Rate: (Lbs/min/ton) = 200 BTU/min divided by the refrigerating effect.

4. CFM Gas to Compressor: Flow rate (Lbs/min/ton) times specific volume (Cu ft/lb) of gas entering the compressor - CFM Gas/Ton.

5. Compression Ratio: Discharge pressure psia divided by suction pressure psia.

6. Reciprocating Compressor Displacement in CFM

= RPM x No. of cylinders x π D² x S x 1 4 1728

where: D = Cylinder Bore in inches and S = Piston Stroke in inches.

7. Volumetric Efficiency: of a compressor is the ratio of the volume of suction gas actually pumped to the displacement or swept volume of the compressor. The biggest factors affecting volu-metric efficiency are: Compression ratio and cylinder clearance volume for reciprocating compressors; Compression ratio and differential pressure for rotary screw compressors.

8. Heat of Compression (BTU/lb): Enthalpy of the discharge gas, leaving the compressor minus the enthalpy of the suction gas entering the compressors.

9. Heat Rejection to the Condenser:

a) Enthalpy of discharge gas leaving the compressor less the enthalpy of the liquid leaving the condenser in BTU/lb times the Refrigerant Flow Rate = Heat of rejection in (BTU/min/ton).

b) Tons of refrigeration times 12,000 BTU/Hr/Ton plus the compressor brake HP times 2545 BTU/Hr/Hp (or her-metic motor kilowatts times 3415 BTU/Hr/kW) = Heat of Rejection in BTU/Hr.

* Refer to Refrigerant Tables or Mollier Charts for thermodynamic properties of the refrigerant.

TD248

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

TECHNICAL TIPS

Technical Tips

Silver Brazing - Inert Gas Prevents Copper Oxide Formation

The purpose of this article on silver brazing is to enlarge on one serious after-effect if proper procedures are not used during sil-ver brazing operations.

The use of high melting point alloys has increased considerably in recent years particularly in supermarkets, processing plants, air conditioning or wherever a large number of joints are used. The inherent mechanical strength of the joint and the reduction of leak possibilities have made this a desirable type of joint. In addition, code requirements in some areas have forced the used of these alloys.

In order for brazing alloys to melt and flow properly, red beat, 620 to 790ºC is required. Copper will react with the oxygen in air at these temperatures to form a scale of copper oxide in air at these temperatures to form a scale of copper oxide on the in-ner walls of tubing, pipe and fittings. The scale is broken off into flakes by the turbulence of flowing liquid refrigerant. The flakes quickly break up into a fine powder which plugs driers, strainers and capillary tubes.

Copper oxide is so finely divided that a filter bed of other mate-rials is usually required in driers before the filtration system in the drier can remove it, thus accounting for the approximately 48 hours needed to remove this material. This assumes that the original drier does not plug. If it does, longer will be required.

Driers are sometimes returned as defective because they have shown an undesirable pressure drop on a new system. In con-junction with other dirt, a substantial accumulation of copper oxide is often the explanation. Chemical analysis readily confirm the condition. The drier is not defective, on the contrary, it has done exactly what it was designed to do - take out the ‘dirt’.

If the air in the line being brazed is replaced with an inert gas such as dry nitrogen, the formation of copper oxide can be elimi-nated. The line should be purged thoroughly and a slow steady flow of nitrogen maintained by means of a pressure reducing valve.

High pressure gas (nitrogen) should never be connected directly to a system but must be metered through a pressure reducing valve for the protection of the user. Too high a rate of flow is un-desirable because of the cooling effect of the gas.

The inert gas method will keep the inside of the copper lines and fittings clean and bright. When it is not completely successful, the trouble is usually attributed to applying heat before all of the air has been displaced.

On large copper pipe, the end of the tubing should be covered with some type of elastic material such as a rubber balloon and a small slit made in the rubber to provide an escape valve. In this manner, the line can be kept full of nitrogen without use of excessive quantities.

The inert gas method, wherever practical, is recommended for repair work. The nitrogen clears the line of refrigerant vapour preventing acid formation due to refrigerant breakdown as well as preventing copper oxide formation.

Many service engineers find it impractical to transport heavy nitrogen cylinders in and out of buildings and have solved the problem by permanently mounting the cylinder on their service truck. The cylinder is equipped with a pressure reducing valve and flexible lines long enough to reach most of their jobs. Purge hose or a similar type of material is satisfactory for the flexible line. The line pressure is held to an absolute minimum with the gas flow just high enough to maintain the required slow, steady rate of flow.

Note:

Cadmium bearing brazing alloys present a dangerous toxic hazard. Extreme care in providing adequate ventilation during brazing operations is an absolute necessity. Inhalation of cad-mium fumes may produce extreme illness or could be fatal.

Trouble Shooting Tips - a list of Do’s and Dont’s for Commercial RefrigerationDo Don´t

• Check suction gas superheat at the compressor. High superheats cause high discharge temperatures and shorten compressor life.

• Check expansion valve superheat using the temperature pressure method (refer to Page TD249). Set to equipment manufacturer’s specification.

• Replace the filter-driers or drier cores when opening the system for service.

• Maintain test instruments in workable calibrated condition.

• Use an accurate liquid line moisture indicator to ensure system dryness.

• Read and observe installation and safety instructions included with a product.

• Familiarise yourself with the operation of a control before attempting to make adjustments or repairs.

• Remember that a thermostatic expansion valve is not a temperature or pressure control.

• Select solenoid valves by line size or port size. Select based on valve capacity.

• Rely on sight or touch for temperature measurements. Use an accurate thermometer.

• Be a ‘parts changer’. Analyse the problem and determine the cause or failure before making adjustments or repairs.

• Attempt to re-use driers or direr blocks once they have been removed from the system.

• Energise a solenoid coil with it removed from a valve. It will burn out in a matter of minutes.

TD249

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

EVAPORATION SUPERHEAT

Evaporation Superheat

Thermostatic Expansion Valve - Superheat

A vapour is superheated whenever its temperature is higher than the saturation temperature corresponding to its pressure. The amount of the superheat equals the amount of temperature increase above the saturation temperature at the existing pres-sure.

For example, a refrigeration evaporator is operating with Refrig-erant 22 at 465 kPa suction pressure. The Refrigerant 22 satura-tion temperature at 465 kPa is 4ºC. As long as any liquid exists at this pressure, the refrigerant temperature will remain 4ºC as it evaporates or boils off in the evaporator.

As the refrigerant moves along in the coil, the liquid boils off into a vapour, causing the amount of liquid present to decrease. All of the liquid is finally evaporated at point B because it has absorbed sufficient heat from the surrounding atmosphere to change the refrigerant liquid to a vapour. The refrigerant gas continues along the coil and remains at the same pressure (465 kPa) however, its temperature increases due to continued ab-sorption of heat from the surrounding atmosphere. When the refrigerant gas reaches the end of the evaporator (Point C), its temperature is 10ºC. This refrigerant gas is now superheated and the amount of superheat is 6ºC or 6ºK (10º - 4º). The de-gree to which the refrigerant gas is superheated depends on the amount of the refrigerant being fed to the evaporator by the T.X. valve and the heat load to which the evaporator is exposed.

Adjustment of Superheat

The function of a T.X. valve is to control the superheat of the suc-tion gas leaving the evaporator in accordance with the valve set-ting. A T.X. valve which is performing this function within reason-able limits can be said to be operating in a satisfactory manner.

Good superheat control is the criterion of T.X. valve performance. It is important that this function be measured as accurately as possible, or in the absence of accuracy, to be aware of the mag-nitude and direction of whatever error is present.

Superheat has been previously defined as the temperature in-crease of the refrigerant gas above the saturation temperature at the existing pressure. Based on this definition, the pressure and temperature of the refrigerant suction gas passing the T.X. valve remote bulb are required for an accurate determination of superheat.

Thus, when measuring superheat, the recommended prac-tice is to install a calibrated pressure gauge connection at the evaporator outlet. In the absence of a gauge connection, a tee installed in the T.X. valve external equalizer line can be sued just as effectively.

A refrigeration type pocket thermometer with appropriate bulb clamp may be used, or more effective is the use of a service type potentiometer (electric thermometer) with thermocouples (leads and probes).

The temperature element from your Temperature Meter should be clamped to the suction line at the point of remote bulb loca-tion and must be insulated against the ambient. Temperature elements of this type, as well as thermometers, will give an aver-age reading of suction line and ambient if not insulated. Assum-ing an accurate gauge and Temperature Meter, this method will provide sufficiently accurate superheat readings for all practical purposes.

On installations where a gauge connection is not available and the valve is internally equalized, there are two alternate methods possible. Both of these methods are approximations only and their use is definitely not recommended.

The first of these is the two temperature method which utilizes the difference in temperature between the evaporator inlet and outlet in temperature between the evaporator inlet and outlet as the superheat. This method is in error by the temperature equivalent of the pressure drop between the two points of tem-perature.

Where the pressure drop between the evaporator inlet and out-let is 7kPa or less, the two temperature method will yield fairly accurate results. However, evaporator pressure drop is usually an unknown and will vary with the load. For this reason, the two temperature methods cannot be relied on for absolute super-heat readings. It should be noted that the error in the two tem-perature method is negative and always indicates a superheat lower than the actual figure.

The other method commonly used to check superheat involves taking the temperature at the evaporator outlet and utilizing the compressor suction pressure as the evaporator saturation pres-sure. The error here is obviously due to the pressure drop in the suction line between the evaporator outlet and the compressor suction gauge.

On self-contained equipment, the pressure drop and resulting error are usually small. However, on large built-up systems or systems with long runs of suction line, considerable discrepan-cies will usually result.

Since estimates of suction line pressure drop are usually not accurate enough to give a true picture of the superheat, this method cannot be relied on for absolute values. It should be noted that the error in this instance will always be positive and the superheat resulting will be higher than the actual value.

Restating, the only method of checking superheat that will yield an absolute value involves a pressure and temperature reading at the evaporator outlet.

Other methods employed will yield a fictitious superheat that can prove misleading when used to analyse T.X. valve performance. By realizing the limitations of these approximate methods and the direction of the error, it is often possible to determine that the cause of a trouble call is due to the use of improper methods of instrumentation rather than any malfunction of the valve.

TD250

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

A GUIDE TO CALCULATING NOISE LEVELS

A Guide to Calculating Noise Levels

Step 1 - SWL of Unit

Enter the Sound Power Level (SWL) of the proposed equipment at the top of the table.

Step 2 - Distance Factor

Determine the shortest distance between the location of the proposed unit and the receiver position (e.g. neighbour). For Simplicity the distance between the unit and the boundary may be acceptable. Circle the corresponding Distance Factor in Column 1.

Step 3 - Barrier Effect

Determine the type of barrier - If any between the proposed unit and the receiver position. Check the section on “Barriers” to determine the situation you have. Remember that an “Ineffective Barrier: is one where there is no barrier or the barrier or fence has holes in it which allows the noise to pass through it (e.g. picket fences, missing planks, decorative openings etc.). Circle the corresponding Barrier Factor in Column 2.

Step 4 - Reflection Factor

Determine the number of reflective surfaces that are within 3 metres of the proposed unit, such as walls and large eaves (do not include the ground). Circle the corresponding Reflection Factor in Column 3.

Step 5 - Resultant Noise Level

Determine the estimated Resultant Noise Level by:

Noise Level = SWL of Proposed Unit - Distance Factor - Barrier Effect - Reflection Factor

Sound Power Level (SWL) of Proposed Unit — dBA

Column 1

Shortest straight line distance from Unit to Receiver position (m)

Distance Factor

1 8

2 14

3 17

4 20

5 22

6 23

7 25

8 25

10 28

Column 3

Reflection Reflection Factor

No reflecting surfaces within 3m

0

One refecting surface within 3m (one wall)

3

Two refecting surfaces with 3m (two walls)

5

Three reflecting surfaces within 3m (two walls and large eaves)

6

Column 2

Barrier Barrier Effect

Ineffective Barrier 0

Effective Barrier

Line of sight to unit not blocked

0

Blocks line of sight to unit

5

High barrier blocks line of sight of unit by more than 1m

8

TD251

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

METRIC CONVERSION CHART

Metric Conversion Chart

Remarks A B C

Multiply By To Obtain

Area: Symbol m²

The SI unit of AREA is the SQUARE METRE

square inches square feet square yards acre hectare (ha)

645.16 0.929 0.836 4047 10,000

mm² m² m² m² m²

Length: Symbol m

The SI unit of LENGTH is the METRE

inches feet yards mile mile"

25.4 0.3048 0.9144 1609 1.609

millimetres (mm) metres (m) metres (m) metres (m) Kilometres (km)

Mass: Symbol kg

The SI unit of MASS is the KILOGRAM

ounce pound ton (2240 lb) short ton (2000 lb) ton (2240 lb) pounds per foot (lb/ft)

28.35 0.436 1016.05 907.2 1.016 1.488

grams (g) kilograms (kg) kg kg tonne (t) kg/m

Volume: Capacity: Symbol m³

The SI unit of VOLUME is the CUBIC METRE

Dry: cubic inch (in³) cubic foot (ft³) cubic yard (yd³) litre (L) litre (L) gallons (lmp)

16,387 0.02832 0.7646 1,000,000 0.001 0.004546

mm³ m³ m³ mm³ m³ m³

Imperial Liquid: fluid ounce pint (20fl.oz) quart (2 pints) gallon (lmp) gallon (US) litre (water 4ºC) Imp.gallons (water 20ºC)

28.41 568.3 1.137 4.546 3.785 1.000 4.536

millilitre (ml) millilitre (ml) litre (L) litre (L) litre (L) kilogram (kg) kilogram (kg)

Volume: Rate Of Flow Symbol m³/s

The SI unit of VOLUME RATE OF FLOW is the CUBIC METRE PER SECOND

Imp. gal. per min (gal/min) Imp. gal. per min Imp. gal. per min

0.000758 0.272765 0.758

m³/s m³/hr litre per second (L/s)

Pressure: Symbol Pa

The SI unit of PRESSURE or stress is the NEWTON PER SQUARE METRE which has been given the name PASCAL

1N/m² = 1Pa = 0.000145lbf/in²

A pascal is the pressure or stress which arises when a force of one newton is applied uniformly over an area of one square metre

lbf/in² kip/in² (1000 psi) lbf/ft² kgf/cm² bar

6.895 6.895 47.88 98.07 100

kPa Mpa Pa kPa kPa

Vertical column (head) of water. (H²O at 20ºC) metres of water feet of water torr (vacuum 1mm Hg. (mercury) 1mm Hg. (mercury) atmosphere (atm) microns

9.79 2.984 0.133 0.133 3.386 101.325 0.133

kPa kPa kPa kPa kPa kPa Pa

Density: Symbol kg/m³

The SI unit of DENSITY is the KILOGRAM PER CUBIC METRE

lb/in³ lb/ft³ lb/yd³

27.68 16.02 0.5933

t/m³ kg/m³ kg/m³

Remarks A B C

Multiply By To Obtain

Velocity: Symbol m/s

The SI unit of VELOCITY is the METRE PER SECOND

ft. per sec (ft/s) ft. per min (ft/min) miles per hour miles per hour

0.3048 0.00508 0.4470 1.609

m/s m/s m/s km/h

Power: Symbol W

The SI unit of POWER is the WATT

Btu per hour (Btu/hr) Horsepower (hp) ton of refrigeration

0.2931 0.7457 3.517

W kW kW

Energy: Symbol J

The SI unit of ENERGY is the JOULE

1J = 1 N.m

A joule is the energy expended or the work done when a force of one newton moves the point of application a distance of one metre in the direction of that force

Electrical Energy kilowatt hour (kW.h)

3.6

MJ

Heat Energy British thermal unit (Btu) Btu/ft³

1.055 37.26

KJ KJ/m³

Mechanical Energy foot poundal (ft.pdl) inch pound-force (in.lbf) foot pound-force (ft.lbf) foot ton force (ft.tonf) metre kilogram force (m.kgf)

0.4214 0.1130 1.356 3.037 9.807

J J00 J KJ J

Force: Symbol N (Newton)

The SI unit of FORCE (kg.m/s²) has been given the special name - NEWTON.

The newton is the force which when applied to a body having a mass of one kilogram, causes an acceleration of one metre per second in the direction of application of the force

Pountal (pdl) Pound-force (lbf) ton-force (tonf) *kilogram-force (kgf)

0.1383 4.448 9.964 9.807

N N kN N

*also known as kilopond (kp)

Force Per Unit Length:

The SI unit is NEWTON/per metre Symbol N/m

pounds-force per inch (Ibf/in) pounds-force per foot (lbf/ft) ton-force per foot (ton/ft)

175.1 14.59 32.69

N/m N/m kN/m

Torque: Symbol N.m (Moment of force

The SI unit of TORQUE is the NEWTON METRE

The NEWTON METRE is the work done when a force of one newton moves the point of application a distance of one metre in the direction of that force.

1N.m = 1J

Poundal-foot (pdl.ft) pound-force inch (lbf.inch) (lbf.inch) pound-force feet (lbf.ft) (lbt.ft) ton-force feet (tonf.ft) Kilogram-force (kgf.m) (kgf.cm)

0.04214 0.113 1.152 1.356 13.83 3.037 9.807 0.09807

N.m N.m kgf.cm N/m kgf.cm kN.m N.m N.m

TD252

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

GENERAL RULES & FIRST AID

General RulesGeneral Rules for handling Fluorocarbon Refrigerants

Safety Equipment

Goggles or face shields, gloves and safety footwear must be worn when filling cylinders, coupling up storage vessels and/or handling bulk fills so as to prevent eye damage or burns should a coupling give way or a line burst.

Keep Away from Fire

No part of any cylinder should ever be subjected to direct flame, steam or temperatures exceeding 50’C. If necessary to warm cylinder to promote more rapid discharge, extreme caution should be taken - an easy and safe way is to place bottom part of cylinder in a container of warm or hot water not over 50’C.

Store Cylinders Upright

Store cylinders in a cool, dry place, away from direct sources of heat. A well ventilated area will ensure that no build up of gas can occur should a cylinder leak or relief valve unseat.

Behaviour in Presence of Open Flame

All commercially available fluorinated hydrocarbon refrigerants are non-inflammable and non-explosive - an extremely impor-tant safety feature. These refrigerants will decompose however, if subjected to sufficiently high temperatures. Over 540’C is re-quired for decomposition, and since the average flame tem-perature is higher, decomposition may occur. It should be noted that only the refrigerant vapour that actually passes through the flame will be affected. When fluorinated hydrocarbon refriger-ants are decomposed by high temperature, they form hydrogen chloride, hydrogen fluoride and small quantities of other gases which may cause ill effects if inhaled in sufficient quantities. Gen-erally, the pungent odour of these products give ample warning of their presence.

Do Not Force Connections

Cylinder connections should fit easily and snugly. Never force them. Use correct tools. Stripped threads can cause leaks and possible loss of refrigerant.

Handle Cylinders Carefully

Cylinders should not be used for ‘rollers’ or supports. Cuts and abrasions may result. Care in handling cylinders will prolong their life.

Read Labels

Because colour of cylinders cannot be relied upon for positive identification, labels should always be read carefully. Colour blindness might interfere with proper identification. If still in doubt, other methods of identification are available from the manufacturer/supplier.

Visual Examination

Each time a cylinder is returned or delivered for re-charging, it should be carefully examined for evidence of corrosion, cuts, dents, bulges, condition of threads, valves, etc, to ensure suit-ability for further service. State Codes also provide for examina-tion and testing of cylinders to ensure their continued use.

Ventilation

Since many materials such as soldering flux, oil, dirt and all re-frigerants decompose at the flame temperatures used in solder-ing, the area in which repair is carried out should be properly ventilated to remove the products of decomposition and com-bustion of all materials. An adequately ventilated work area is good practice at any time, but especially when an open flame of a leak detector or welding torch is to be used in the presence of ‘fluorocarbon’ refrigerants.

Never Transfer

Refrigerant cylinders are labelled and identified for a particular refrigerant. Never put a different refrigerant into a cylinder la-belled for another refrigerant.

Check Pressure

The pressure within the cylinder must be greater than in the sys-tem to cause the refrigerant to flow into the system. Pressure should be checked before charging.

Health Effects and First Aid

Swallowed

This product is a vapour at ambient temperature and pressure: therefore any liquid present in an open vessel will be boiling at a very low temperature and accidental contact with mouth or throat tissue would generate severe frost burning, but it is obvi-ously extremely unlikely.

Eye

Frost burning of eye tissue would occur in the event of accidental contact. In cases of frost bite: Rinse with plenty of water and seek medical advice.

Inhaled

The vapour of this product is denser than air and may reduce the available oxygen. The symptoms likely to be experienced upon inhalation of the vapour include: narcososi, anaesthesia, respiratory depression, unconsciousness and possible asphyxi-ation. In addition, inhalation may lead to cardiac arrythmias in susceptible individuals.

Move to fresh air, rest, half upright position, loosen clothing. Give oxygen or artificial respiration if there is any difficulty in breath-ing. Apply external cardiac massage in case of cardiac arrest.

Skin

Contact with skin of boiling liquid may cause frost bite. In cases of frost bite : DO NOT remove clothes. Rinse skin with plenty of water. Treat frost bite as for thermal burns. Seek medical advice.

Advice to Doctor

Ensure first aid procedures have been carried out. Treat sympto-matically. Avoid the use of adrenaline.

TD253

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

PRESSURE TEMPERATURE CHART

Pressure Temperature Chart R2

2R5

02R7

17R7

44Te

mp

°CkP

Ag

psig

kPA

gps

igkP

Ag

psig

kPA

gps

igTe

mp

°F-5

0-3

5.5

10.5

*-1

9-2

.8-5

9.2

17.5

*58

284

.5-5

8-4

8-2

8.6

8.4*

-10

-1.5

-54.

316

*63

992

.7-5

4.4

-46

-21.1

6.2*

-1-0

.1-4

8.9

14.4

*70

010

2-5

0.8

-44

-13

3.8*

81.2

-42.

712

.6*

764

111

-47.

2-4

2-4

.21.2

* 19

2.8

-35.

910

.6*

833

121

-43.

6-4

00.

010.

530

4.4

-28.

38.

4*90

513

1-4

0-3

810

1.542

6.1

-20.

36*

981

142

-36.

4-3

622

3.5

547.

8-1

1.63.

4*10

6115

4-3

2.8

-34

324.

668

9.9

-2.1

0.6

*11

4516

6-2

9.2

-32

507.

282

11.9

8.3

112

3417

9-2

5.6

-30

639.

198

14.2

19.4

2.6

1328

193

-22

-28

8012

114

16.5

31.5

4.4

1426

207

-18.

4-2

691

1313

219

.244

.66.

715

9223

1-1

4.8

-24

108

1615

021

.858

.68.

716

3823

7-1

1.2-2

212

618

170

24.7

73.8

1117

5125

4-7

.6-2

014

521

191

27.7

90.1

1318

7027

1-4

-18

164

2421

330

.910

815

1994

289

-0.4

-16

195

2723

634

.312

618

2124

308

3.2

-14

207

3026

137

.914

621

2259

328

6.8

-12

231

3328

741

.716

824

2401

348

10.4

-10

254

3731

445

.619

128

2549

370

14-8

284

4134

349

.821

531

2703

392

17.6

-631

045

373

54.1

242

3528

6341

521

.2-4

334

4840

558

.826

939

3030

439

24.8

-236

152

438

63.6

299

4332

0446

528

.40

398

5847

368

.732

848

3285

476

322

430

6251

074

382

5337

6954

735

.64

465

6754

879

.539

758

4183

607

39.2

650

473

588

85.3

433

6346

3067

142

.88

542

7963

091

.447

369

5111

741

46.4

1058

485

673

97.7

513

7456

2981

650

1262

290

718

104.

255

581

5903

856

53.6

1466

897

766

111.2

605

8861

8889

757

.216

716

104

815

118.

365

495

6484

940

60.8

1876

911

286

612

5.7

704

102

6792

985

64.4

2081

411

892

013

3.5

755

110

7114

1032

6822

866

126

975

141.5

811

118

71.6

2491

713

310

3314

9.9

868

126

75.2

2697

514

110

9315

8.6

930

135

78.8

2810

4015

111

5516

7.6

995

144

82.4

3011

0716

112

1917

6.9

1065

154

8632

1165

169

1286

186.

611

3016

489

.634

1230

178

1355

196.

712

0317

493

.236

1300

189

1426

207

1277

185

96.8

3813

7820

015

0021

7.7

1369

199

100.

440

1448

210

1577

228.

914

4921

010

442

1525

221

1656

240.

315

4322

410

7.6

4416

1023

317

3825

2.2

1630

236

111.2

4616

8824

518

2326

4.6

1722

250

114.

848

1770

257

1911

277.

418

2026

411

8.4

5018

5526

920

0129

0.4

1914

278

122

5219

5028

320

9530

4.1

2005

291

125.

654

2050

297

2192

318.

121

1031

912

9.2

(ISCE

ON

49)

(ISCE

ON

59)

(ISCE

ON

69L

)(IS

CEO

N 7

9)

R134

AR4

06A

R409

AR4

13A

R407

CR4

10A

R417

AR4

04A

R507

R408

AR4

03B

R422

ATe

mp

°CkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

gkP

Ag

kPA

g-5

0-7

1-5

09

-25

-23

-12

-23

1-4

8-6

7-4

521

-18

-15

-3-1

712

-46

-63

-39

33-1

1-6

7-8

24-4

4-5

9-3

346

-24

171

35-4

2-5

4-2

717

617

1528

1147

-40

-43

-49

-20

2976

1626

4022

6021

.4-3

8-3

7-4

3-1

241

9329

3953

3473

35.1

-36

-35

-30

-37

-455

111

3752

6746

8849

.6-3

4-2

8-2

4-3

14

6813

049

6682

6010

457

.2-3

2-2

1-1

6-2

314

8115

061

8198

7411

873

.7-3

0-1

4-9

-16

2495

172

7497

114

8913

890

.9-2

8-5

0-7

3411

019

588

114

132

105

157

110.

2-2

63

92

4511

821

910

313

315

112

317

813

0.2

-24

1419

1157

128

245

119

152

171

141

199

141.2

-22

2629

2170

136

273

135

173

193

161

220

163.

3-2

039

4033

8415

630

315

319

521

618

124

318

7.4

-18

4952

4498

177

334

171

219

240

203

267

212.

9-1

659

6557

114

200

367

191

243

265

227

295

240.

5-1

472

7871

130

224

402

211

270

292

251

320

254.

9-1

286

9285

147

249

438

233

297

320

277

348

285.

2-1

010

110

710

016

527

647

725

632

635

030

538

231

6.9

-811

812

311

718

430

451

828

035

738

233

441

235

0.7

-613

514

013

420

433

456

130

539

041

536

444

638

6.5

-415

315

815

222

636

560

733

242

445

039

648

340

5.1

-217

217

717

224

839

865

436

046

048

643

052

044

4.4

019

219

719

227

244

070

438

949

852

546

556

048

5.7

221

121

721

429

750

075

742

053

756

550

260

352

9.2

422

924

023

732

352

981

245

257

960

854

164

457

5.3

625

326

326

235

056

686

948

562

365

258

268

959

9.4

828

328

728

737

960

493

052

066

969

862

573

264

910

313

313

314

409

645

993

557

716

747

670

783

709.

712

342

340

342

441

688

1059

595

766

798

716

831

795.

114

372

368

372

474

732

1128

635

819

851

765

886

854.

416

403

397

404

508

779

1200

676

873

906

816

942

884.

718

436

428

437

544

828

1275

719

929

964

869

998

947.

420

469

461

471

582

880

1353

764

989

1024

920

1057

1013

.522

507

495

507

621

934

1435

811

1049

1087

980

1113

1083

.124

544

530

545

662

990

1520

859

1119

1152

1040

1179

1154

.826

584

567

585

705

1049

1608

910

1179

1221

1100

1244

1192

.728

626

605

626

750

1110

1701

962

1249

1291

1170

1313

1269

.130

668

645

670

796

1175

1797

1016

1329

1365

1240

1388

1349

.832

715

687

715

844

1242

1896

1073

1399

1442

1310

1462

1433

.834

761

730

762

895

1311

2000

1131

1479

1521

1380

1540

1521

.336

811

775

811

947

1384

2108

1192

1559

1604

1460

1620

1566

.838

863

822

863

1001

1460

2220

1254

1639

1689

1530

1700

1659

.840

915

871

920

1057

1539

2336

1319

1729

1778

1610

1784

1756

.342

972

922

970

1115

1621

2456

1386

1819

1870

1700

1872

1857

.544

1029

974

1030

1176

1707

2581

1455

1909

1966

1790

1964

1962

.346

1090

1029

1090

1238

1796

2710

1527

2009

2064

1880

2057

2016

4811

5310

8511

5013

0318

8828

4416

0121

0921

6719

7021

5121

27.6

5012

1711

4412

2013

7019

8529

8316

7722

0922

7320

6022

5022

43.4

5212

8712

0412

9014

4020

8531

2617

5623

1923

8221

6023

5823

6454

1356

1267

1360

1512

2188

3274

1837

2429

2496

2270

2464

2488

.7

TD254

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

PROPERTIES OF REFRIGERANTS

Properties of Refrigerants

Refrigerant R407cKLEA66

R480aFX10

R409aFX56

R409bFX57

R410aAZ20

R413aISCEON 49

R500 R502 R503 R507AZ50

R600aButane

R717Ammonia

Boiling Point at 101 kPa- °C -43.6 -43.5 -34.2 -36.6 -51.4 -35 -33.5 -45.4 -88.7 -46.7 -11.8 -33.3

Temp. Glide at 101 kPa K 7.2 0.7 7.1 7.7 0 7.1 0 0 0 0 0 0

Critical Temperature 'C 87.3 83.5 107 116 84.9 101.3 105.5 82. 2 195 70.9 135 133

Critical Pressure kPa 4820 4340 4500 4700 4950 4110 4420 4075 4340 3793 3631 11417

Latent Heat of Vapourisation

at 101 kPa kj/Kg

250.1 227.2 220.2 220.3 271.6 214.6 201 172 179.4 196.1 355.2

Vapour Pressureat 25°C kPa 1002.8 1147.9 644 692 1646.9 717.1 770 1160 4290 1286 351.8

Liquid Density at 25°C Kg/m³ 1139.22 1062.1 1215.9 1228.4 1083.8 1169.6 1160 1220 1230 1041.6 552.3

Vapour Density at 101 kPa Kg/m³ 4.507 4.712 4.91 4.881 4.064 5.272 5.3 4.79 6.03 5 449 4.392

Ozone Depletion Potential (ODP) 0 0.019 0.04 0.039 0 0 0.605 0.224 0.599 0 0 0

Global Warming Potential (GWP)

(CO²=1)

1370 3060 1530 1510 1300 1510 5210 5590 11700 3900 3 1

Flammability Limit at 25°C None None None None None Worst case of

Fraction-ation

flamm-able

None None None None 1.7% 15%

Variation in Composition of Blended Refrigerants in Case of LeakageIn the following, we make the distinction between:

• Nearazeotropicmixtures(havingalowtemperatureglidetypicallylowerthan3K)

• Azeotropicmixtures(havingatemperatureglideequaltozeroK)

R404a and R408a are near azeotropic mixtures with a glide lower than 1 K.

The composition of the mixtures does not change when a leak occurs in a homogeneous phase. That is the case at the evaporator outlet (superheated vapour) or at the condenser outlet (subcooled liquid).

By contrast, marked differences of behaviour appear between the different types of mixtures during a leak in the two phase region equilibrium.

For non-azeotropic mixtures, the ‘more volatile’ components escape in preceding order, altering to a great extent the composition of the mixture remaining in the installation, resulting in change of performance.

For near azeotropic or real azeotropic mixtures, leak rates of all components of the mixture are very close; thus during a leakage, com-position of refrigerant remaining in the installation is not affected significantly.

For all blended refrigerants it is stated by some manufacturers that after a leakage of 50% of the initial charge, changes in composition are less than 3% by weight.

Like R502 the new blended refrigerants must always be introduced in the liquid phase in the installation. Introduction in the gas phase, at the compressor suction, may increase the charging time of the installation and may alter performance of the mixture charged.

*For a non azeotropic mixture the change process liquid to vapour occurs over a range of temperatures (glide).

TD255

Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.

Tech

nica

l Dat

a

CONVERSION DATA

Summary of Common Conversion Factors

Length

Millimetres Centimetres Inches Feet Yards Metres Kilometres Miles1 0.1 0.03937 0.003281 0.0010936 0.001 0.000001 0.000000621410 1 0.3937 0.032808 0.010936 0.01 0.00001 0.00000521425.4 2.54 1 0.08333 0.027777 0.254 0.0000254 0.00001578304.8 30.48 12 1 0.3333 0.3048 0.0003048 0.0001893914.4 91.44 36 3 1 0.9144 0.0009144 0.00056821000 100 39.37 3.2808 1.0936 1 0.001 0.00062141,000,000 100,000 39,370 3280.8 1093.6 1000 1 0.62141,609,350 160,935 63,360 5280 1760 1609.35 1.60935 1

Mass

Grams Ounces Pounds Kilograms US Ton (Short) Imp Ton (Long) Metric Tonne1 0.03527392 0.00220462 0.001 0.05110231 0.0698426 0.05128.3496 1 0.0625 0.0283496 0.043125 0.04279 0.04283496453.593 16 1 0.453593 0.0005 0.0344642 0.034535931000 35.27392 2.20462 1 0.00110231 0.03984206 0.0001907,186 32,000 2000 907.186 1 0.89285 0.9071861,016,050 35,840 2240 1016.05 1.12 1 1.016051,000,000 35,273.92 2204.62 1000 1.10231 0.984206 1

Energy or Work

Joules (1 Joule = 107 Ergs)

Foot - Pounds Kilogram Metres

Litre - Atmosphere

HorsepowerHours

KilowattHours

KilogramsCalories

British Thermal Units

Lbs Carbon Oxidised with Perfect Efficiency

Lbs Water Evaporated from and at 100°C

1 0.7373 0.101937 0.0098705 0.063727 0.06278 0.0323795 0.039486 0.07642 0.0696621.3562 1 0.138255 0.013826 0.06505 0.063766 0.0332396 0.0012861 0.078808 0.05135269.81 7.233 1 0.09677 0.053653 0.052724 0.002343 0.009302 0.0663718 0.0595895101,3667 74,7386 10.333 1 0.043774 0.042794 0.0242 0.0961 0.056583 0.0499072,685,443 1,980,000 273,746 26,490.4 1 0.7457 641.477 2546.5 0.174 2.623,600,000 2,655,220 367,100 35,526.95 1.341 1 860.238 3415 0.234 3.524185.8291 3087.35 426.843 41.309 0.001558 0.0011623 1 3.9683 0.0329909 0.0045011054.198 778 107.5 10.40277 0.033927 0.032928 0.2519 1 0.04685 0.0010315387,041.6 11,352,000 1.569,527.5 151,894.66 5.733 4.275 3,677.74 14,600 1 15.051,023,000 754,525 104.320 10,096.77 0.3811 0.2841 244.44 970.4 0.066466 1

Volume and Capacity

Cubic Inches

Cubic Feet

Cubic Feet

Litres US Quarts US Gallons Imperial Gallons

US Bushels Water at Max Density 4°CLiquid Dry Liquid Dry Pounds Kgs

1 0.035787 0.042143 0.016384 0.01731 0.01488 0.004329 0.003721 0.0036065 0.034651 0.0361275 0.01638721728 1 0.037037 28.317 29.92208 25.713 7.48052 6.4282 6.2321 0.803564 62.4283 28.31746,656 27 1 764.56 807.895 694.278 201.974 173.569 168.266 21.6962 1685.56 764.55961,023.4 35.3145 1.307941 1000 1056.68 908.1 264.17 227.02 220.083 28.38 2204.62 100061.0234 0.0353145 0.001308 1 1005668 0.9081 0.26417 0.22702 0.22083 0.02838 2.20462 157.75 0.03342 0.001238 0.94636 1 0.8595 0.25 0.2149 0.20828 0.02686 2.08636 0.9463567.18 0.03888 0.00144 1.1009 1.1635 1 0.2909 0.25 0.24235 0.03125231 0.133681 0.004951 3.78543 4 3.4378 1 .08595 0.833111 0.10743 8.34545 3.78543268.75 .015552 0.00576 4.404 4.654 4 1.1635 1 0.96932 0.125277.274 0.160459 0.0059429 4.54374 4.80128 4.1267 1.20032 1.0317 1 0.12896 10.0172 4.543732150 1.24446 0.04609 35.238 37.2353 32 9.3088 8 7.81457 127.6798 0.0160184 0.035929 0.453592 0.4793 0.119825 0.0998281 1 0.453593

Pressure

psi atms. Ft. Hd H2O @ 20°C

Inches H2O Kg/cm² MetresH2O

Inches Hg. at 20°C

mm Hg. Cm Hg. Bar Millibar (mb)

KPa

1 0.068 2.31 27.72 0.07 0.704 2.043 51.884 5.188 0.069 68.947 6.89514.696 1 33.659 407.513 1.033 10.351 30.019 762.48 76.284 1.013 1013 101.3250.433 0.029 1 12 0.03 0.305 0.884 22.452 2.245 0.03 29.837 2.9840.36 0.0025 .0833 1 0.0025 0.025 0.074 1.871 0.187 0.0025 2.486 0.24914.233 0.968 32.867 394.408 1 10.018 29.054 737.959 73.796 0.981 980.662 98.0661.422 0.097 3.287 39.37 0.099 1 2.905 73.796 7.379 0.098 98.066 9.8070.489 0.033 1.131 13.575 0.034 0.345 1 25.4 2.54 0.034 33.753 3.3750.019 0.0013 0.045 0.534 0.0014 0.0136 0.039 1 0.1 0.001 1.329 0.1330.193 0.0131 0.455 5.34 0.014 0.136 0.393 10 1 0.0133 13.29 1.32814.503 0.987 33.514 402.164 10.2 10.211 29.625 752.47 75.247 1 1000 1000.014 0.0009 0.033 0.402 0.001 0.0102 0.029 0.752 0.075 0.001 1 0.10.145 0.0098 0.335 4.021 0.01 0.102 0.296 7.525 0.0752 0.01 10 1

TERMS & CONDITIONS OF TRADE1. DEFINITIONS

1.1 “Realcold” shall mean Realcold Limited., or any agents or employees thereof.

1.2 “Customer” shall mean the Customer, any person act-ing on behalf of and with the authority of the Customer, or any person purchasing products and services from Realcold.

1.3 “Goods” shall mean:

1.3.1 all Goods of the general description specified on the front of this agreement and supplied by Real-cold to the Customer; and

1.3.2 all Goods supplied by Realcold to the Customer; and

1.3.3 all inventory of the Customer that is supplied by Realcold; and

1.3.4 all Goods supplied by Realcold and further identi-fied in any invoice issued by Realcold to the Cus-tomer, which invoices are deemed to be incorpo-rated into and form part of this agreement; and

1.3.5 all Goods that are marked as having been sup-plied by Realcold or that are stored by the Cus-tomer in a manner that enables them to be identi-fied as having been supplied by Realcold; and

1.3.6 all of the Customer’s present and after-acquired Goods that Realcold has performed work on or to or in which goods or materials supplied or fi-nanced by Realcold have been attached or incor-porated.

1.3.7 The above descriptions may overlap but each is independent of and does not limit the others.

1.4 “Goods and Services” shall also mean all goods, prod-ucts, services and advice provided by Realcold to the Customer and shall include without limitation the design, manufacture, development, sale, installation, repair and maintenance of industrial refrigeration equipment and the supply of componentry and parts and all charges for labour, hire charges, insurance charges, or any fee or charge associated with the supply of Goods and Ser-vices by Realcold to the Customer.

1.5 “Price” shall mean the cost of the Goods and Services as agreed between Realcold and the Customer and includes all disbursements eg charges Realcold pay to others on the Customer’s behalf subject to clause 4 of this contract.

2. ACCEPTANCE

2.1 Any instructions received by Realcold from the Customer for the supply of Goods and Services shall constitute a binding contract and acceptance of the terms and con-ditions contained herein.

3. COLLECTION AND USE OF INFORMATION

3.1 The Customer authorises Realcold to collect, retain and use any information about the Customer, for the purpose of assessing the Customer’s credit worthiness, enforcing any rights under this contract, or marketing any Goods and Services provided by Realcold to any other party.

3.2 The Customer authorises Realcold to disclose any infor-mation obtained to any person for the purposes set out in clause 3.1.

3.3 Where the Customer is a natural person the authorities under clauses 3.1 and 3.2 are authorities or consents for the purposes of the Privacy Act 1993.

4. PRICE

4.1 Where no price is stated in writing or agreed to orally the Goods and Services shall be deemed to be sold at the current amount as such Goods and Services are sold by Realcold at the time of the contract.

4.2 The price may be increased by the amount of any rea-sonable increase in the cost of supply of the Goods and Services that is beyond the control of Realcold between the date of the contract and delivery of the Goods and Services.

5. PAYMENT

5.1 Payment for Goods and Services shall be made in full on or before the 20th day of the month following the date of the invoice (“the due date”). Progress payments apply to large contracts.

5.2 Interest may be charged on any amount owing after the due date at the rate of 2.5% per month or part month.

5.3 Any expenses, disbursements and legal costs incurred by Realcold in the enforcement of any rights contained in this contract shall be paid by the Customer, including any reasonable solicitor’s fees or debt collection agency fees.

5.4 Receipt of a cheque, bill of exchange, or other negotiable instrument shall not constitute payment until such nego-tiable instrument is paid in full.

5.5 A deposit may be required.

6. QUOTATION

6.1 Where a quotation is given by Realcold for Goods and Services:

6.1.1 Unless otherwise agreed the quotation shall be valid for thirty (30) days from the date of issue; and

6.1.2 The quotation shall be exclusive of goods and services tax unless specifically stated to the con-trary;

6.1.3 Realcold reserve the right to alter the quotation because of circumstances beyond its control.

TERMS & CONDITIONS OF TRADE6.2 Where Goods and Services are required in addition to

the quotation the Customer agrees to pay for the addi-tional cost of such Goods and Services.

7. RISK

7.1 The Goods and Services remain at Realcold’s risk until delivery to the Customer.

7.2 Delivery of Goods and Services shall be deemed com-plete when Realcold gives possession of the Goods and Services directly to the Customer or possession of the Goods and Services is given to a carrier, courier, or other bailee for purposes of transmission to the Customer.

8. TITLE AND SECURITY (PERSONAL PROPERTY SECURITIES ACT 1999)

8.1 Title in any Goods and Services supplied by Realcold passes to the Customer only when the Customer has made payment in full for all Goods and Services pro-vided by Realcold and of all other sums due to Realcold by the Customer on any account whatsoever. Until all sums due to Realcold by the Customer have been paid in full, Realcold has a security interest in all Goods and Services.

8.2 If the Goods and Services are attached, fixed, or incor-porated into any property of the Customer, by way of any manufacturing or assembly process by the Customer or any third party, title in the Goods and Services shall remain with Realcold until the Customer has made pay-ment for all Goods and Services, and where those Goods and Services are mixed with other property so as to be part of or a constituent of any new Goods and Services, title to these new Goods and Services shall deemed to be assigned to Realcold as security for the full satisfac-tion by the Customer of the full amount owing between Realcold and Customer.

8.3 The Customer gives irrevocable authority to Realcold to enter any premises occupied by the Customer or on which Goods and Services are situated at any reason-able time after default by the Customer or before default if Realcold believes a default is likely and to remove and repossess any Goods and Services and any other property to which Goods and Services are attached or in which Goods and Services are incorporated. Realcold shall not be liable for any costs, damages, expenses or losses incurred by the Customer or any third party as a result of this action, nor liable in contract or in tort or otherwise in any way whatsoever unless by statute such liability cannot be excluded. Realcold may either resell any repossessed Goods and Services and credit the Customer’s account with the net proceeds of sale (after deduction of all repossession, storage, selling and other costs) or may retain any repossessed Goods and Ser-vices and credit the Customer’s account with the invoice value thereof less such sum as Realcold reasonably determines on account of wear and tear, depreciation, obsolescence, loss or profit and costs.

8.4 Where Goods and Services are retained by Realcold pursuant to clause 8.3 the Customer waives the right to receive notice under s.120 of the Personal Property Se-curities Act 1999 (“PPSA”) and to object under s.121 of the PPSA.

8.5 The Company may register a Financing Statement over the Goods and the customer shall agree to waive the right to a verification statement for purposes of s.148 of the PPSA.

8.6 The following shall constitute defaults by the Customer:

8.6.1 Non payment of any sum by the due date.

8.6.2 The Customer intimates that it will not pay any sum by the due date.

8.6.3 Any Goods and Services are seized by any other creditor of the Customer or any other creditor inti-mates that it intends to seize Goods and Services.

8.6.4 Any Goods and Services in the possession of the Customer are materially damaged while any sum due from the Customer to Realcold remains un-paid.

8.6.5 The Customer is bankrupted or put into liquida-tion or a receiver is appointed to any of the Cus-tomer’s assets or a landlord distrains against any of the Customer’s assets.

8.6.6 A Court judgment is entered against the Custom-er and remains unsatisfied for seven (7) days.

8.6.7 Any material adverse change in the financial po-sition of the Customer.

9. SECURITY INTEREST FOR SERVICE PROVIDERS

9.1 The Customer gives Realcold a security interest in all of the Customer’s present and after-acquired property that Realcold has performed services on or to or in which goods or materials supplied or financed by Realcold have been attached or incorporated.

10. PAYMENT ALLOCATION

10.1 Realcold may in its discretion allocate any payment re-ceived from the Customer towards any invoice that Real-cold determines and may do so at the time of receipt or at any time afterwards and on default by the Customer may reallocate any payments previously received and allocated. In the absence of any payment allocation by Realcold, payment shall be deemed to be allocated in such manner as preserves the maximum value of Re-alcold’s purchase money security interest in the Goods and Services.

TERMS & CONDITIONS OF TRADE11. GENERAL LIEN

11.1 The Customer agrees that Realcold may exercise a gen-eral lien against any Goods and Services or property be-longing to the Customer that is in the possession of Re-alcold for all sums outstanding under this contract and any other contract to which the Customer and Realcold are parties.

11.2 If the lien is not satisfied within seven (7) days of the due date Realcold may, having given notice of the lien at its option either:

11.2.1 Remove such Goods and Services and store them in such a place and in such a manner as Realcold shall think fit and proper and at the risk and ex-pense of the Customer; or

11.2.2 Sell such Goods and Services or part thereof upon such terms as it shall think fit and apply the pro-ceeds in or towards discharge of the lien and costs of sale without being liable to any person for damage caused.

12. DISPUTES AND RETURN OF GOODS

12.1 No claim relating to the Goods and Services will be con-sidered unless made within seven (7) days of delivery.

12.2 No Goods will be accepted for return without the prior consent of Realcold. Any Goods accepted for return will be subject to a 10% restocking fee and must be in resale-able undamaged condition and in original packaging.

13. LIABILITY

13.1 The Consumer Guarantees Act 1993, the Sale of Goods Act 1908, the Fair Trading Act 1986 and other statutes may imply warranties or conditions or impose obliga-tions upon Realcold which cannot by law (or which can only to a limited extent by law) be excluded or modified. In respect of any such implied warranties, conditions or terms imposed on Realcold, Realcold’s liability shall, where it is allowed, be excluded or if not able to be ex-cluded only apply to the minimum extent required by the relevant statute.

13.2 Except as otherwise provided by clause 13.1 Realcold shall not be liable for:

13.2.1 Any loss or damage of any kind whatsoever, aris-ing from the supply of Goods and Services by Realcold to the Customer, including consequen-tial loss whether suffered or incurred by the Cus-tomer or another person and whether in contract or tort (including negligence) or otherwise and ir-respective of whether such loss or damage arises directly or indirectly from Goods and Services pro-vided by Realcold to the Customer; and

13.2.2 The Customer shall indemnify Realcold against all claims and loss of any kind whatsoever how-ever caused or arising and without limiting the generality of the foregoing of this clause whether caused or arising as a result of the negligence of Realcold or otherwise, brought by any person in connection with any matter, act, omission, or error by Realcold its agents or employees in connection with the Goods and Services.

14. WARRANTY

14.1 Manufacturer’s warranty applies where applicable.

14.2 Any written warranty provided by Realcold to the Cus-tomer shall also form part of these terms and conditions of trade.

15. COPYRIGHT AND INTELLECTUAL PROPERTY

15.1 Realcold, owns and has copyright in all designs, speci-fications, documents, work and software produced by Realcold in connection with the Goods and Services pro-vided pursuant to this contract and the client may use the Goods and Services only if paid for in full and for the purpose for which they were intended and supplied by Realcold.

16. CONSUMER GUARANTEES ACT

16.1 The guarantees contained in the Consumer Guarantees Act 1993 are excluded where the Customer acquires Goods and Services from Realcold for the purposes of a business in terms of section 2 and 43 of that Act.

17. PERSONAL GUARANTEE OF COMPANY DIRECTORS OR TRUSTEES

17.1 If the Customer is a company or trust, the director(s) or trustee(s) signing this contract, in consideration for Real-cold agreeing to supply Goods and Services and grant credit to the Customer at their request, also sign this contract in their personal capacity and jointly and sever-ally personally undertake as principal debtors to Real-cold the payment of any and all monies now or here-after owed by the Customer to Realcold and indemnify Realcold against non-payment by the Customer. Any personal liability of a signatory hereto shall not exclude the Customer in any way whatsoever from the liabilities and obligations contained in this contract. The signato-ries and Customer shall be jointly and severally liable under the terms and conditions of this contract and for payment of all sums due hereunder.

TERMS & CONDITIONS OF TRADE18. MISCELLANEOUS

18.1 Realcold shall not be liable for delay or failure to perform its obligations if the cause of the delay or failure is be-yond its control.

18.2 Failure by Realcold to enforce any of the terms and con-ditions contained in this contract shall not be deemed to be a waiver of any of the rights or obligations Realcold has under this contract.

18.3 If any provision of this contract shall be invalid, void or il-legal or unenforceable the validity existence, legality and enforceability of the remaining provisions shall not be af-fected, prejudiced or impaired.

19. OVERSEAS CUSTOMER - Ownership and Risk

If the Customer is not located in New Zealand, Clause 8 & 9 do not apply and are replaced by the following:

19.1 The ownership and legal title of the Goods shall remain with Realcold until:

19.1.1 payment in full is made for the Goods; and

19.1.2 any other moneys owing by the Customer to Real-cold have been paid in full.

19.2 Notwithstanding that ownership in the Goods may not have passed to the Customer risk in the Goods shall pass to the Customer when the Goods are delivered to the Customer or into the custody of the party acting on the Customer’s behalf and the Customer shall be obliged to insure the Goods from the time of delivery to the Cus-tomer and pending payment in full insure the Goods in the name of Realcold and the Customer for their respec-tive interest.

19.3 If payment is over due in whole or in part in respect of any of the Goods Realcold may (without prejudice to any of its other rights) recover and/or resell the Goods or the mixed goods referred to in clause 19.6 or any of them and may enter upon the Customer’s premises or any other place where the Goods and/or the mixed goods are stored by its servants or agents for that purpose (and the Customer grants to Realcold an irrevocable right and authority to so recover, re enter and re sell), provided that Realcold may only recover and resell for its own account sufficient of the Goods and/or the mixed goods to satisfy all unpaid liability in respect of the Goods and the costs of resale. If any excess is recovered by RE, it shall not be liable in damages but shall account for the excess to the Customer.

19.4 Until payment is made in full by the Customer for the Goods, the Customer holds the Goods as bailee for Re-alcold and will store the Goods in such a manner that they are clearly identifiable as the property of Realcold and will keep separate records in respect of the Goods.

19.5 If the Goods are sold or otherwise disposed of by the Customer prior to payment in full, the Customer will have been deemed to have done so as agent for Realcold and the proceeds of such sale will be the property of Re-alcold. The Customer will hold the proceeds of such sale on trust, on account for RE, and keep them in a separate fund from its own money.

19.6 If any of the Goods are mixed or incorporated in other Goods (the “mixed goods”) before payment, the Custom-er agrees that the property in the mixed goods shall be and remain with Realcold until such payment has been made in full. The Customer shall hold the mixed goods as bailee for Realcold and will store the mixed goods in such a manner that they are clearly identifiable as the property of Realcold and will keep separate records in respect of the same. If the Customer sells the mixed goods it will hold the proceeds of such sale on trust for Realcold and will account to Realcold for the value of the Goods and keep the proceeds in a fund separate from its own money and will keep separate records in respect of such money.

19.7 Where Realcold has reasonable cause to believe:

19.7.1 The Customer has not strictly complied with these Terms and Conditions and, in particular, default of payment in accordance with clause 5; or

19.7.2 The Customer has or will commit an act of bank-ruptcy or (being a company) has had a receiver appointed or about to be appointed, or is de-clared insolvent; Realcold may recover any or all of the Goods or the mixed goods and re sell the Goods or the mixed goods and for such pur-pose may at any time of the day or night enter by force if necessary upon any promises where such Goods or mixed goods are reasonably thought to be stored (and the Customer grants to Realcold an irrevocable right and authority to so recover, re enter and re sell).

19.8 In exercising its rights pursuant to this clause, Realcold shall be entitled to deduct from any sale of Goods or mixed goods recovered from the Customer all the liabili-ties and expenses (including legal expenses) incurred by Realcold in enforcing or attempting to enforce its rights pursuant to this clause 19.

Catalogue

Index

IndexA

Accumulators CA60

AC-Tabs AC33

Air Conditioning CC78

Air Conditioning Thermostats AC36, CT136

Air Cooled CP202

Air Cooled Condensers CP209

AirDefrostCP212–CP215

Allen Key CT132

Ammonia IN171, IN183

Anti Siphoning AC34

Auto Purger IN181, IN182

Axial In-Line Fans AC46

B

Ball Valves CV148

Below Wall Unit AC35

Bending Springs CT132

Bernzomatic CB62

Boots AC42

Brackets & Bases AC27

Brass Fittings CF100, CF101

Brazing Alloy CB61

Bulk Head AC07, AC14

C

Capacity Controls CP208

Capillary CT137

Capillary Service Packs CT137

Capillary Tools CT137

Carel CE95

Carly CS126

Carly Turboil CO117

Cassette AC07, AC08, AC14

Ceiling Fan AC44

Centrifugal In-Line Fans AC46

Charging Equipment CT130

Charging Hoses CT127

Check Valves CV150, IN183

Chilled Water Packages CP222

Commercial Thermostats CT135

Compact Pumps AC34

Components & Fittings AC36

Compressor Lubricants CL114

Compressor Receiver CP206

Compressors CX167, CP223

Condensate Drain AC30, AC31

Condensate Pumps AC32, AC35

Condensers - Ammonia CP209

CondensingUnitsCX167,CP196–CP201,CP223

Control Panels CE96

Control Valves - Steel IN177

Cool Breeze AC18

Copeland CP203

CopelandScrollCC75–CC79,CP207,CP208

Copper Fittings CF102

Couplers CT128

Crankcase Heaters CC73

Cushion Side Entry Box AC42

Custom Build CP204

Custom Design CP199, CP222

D

Danfoss IN174

Deburring Tool CT130

Defrost Controls CD88, CD89

Defrost Safety CD89

Diffuser AC40, AC41

Discharge Line Mufflers CD94

Domestic Thermostats CT135

Down Discharge AC20

Drainage AC28

DriersCD90–CD94

Dual Pressure Controls CP119

Ducted AC09

Duct Fittings AC39

Ducting Accessories AC38

E

Easypack CP199, CP200

Eclipse Air Curtains AC17

Eggcrate Grille AC43

Electrical AC36

Electric Defrost CP213, CP214, CP215

Electronic Controls CE95, CE96

Energy - Recovery Ventilation AC16

Evaporative Air Conditioning AC18

EvaporativeCoolingAC24–AC26

Evaporator Mounting Kits CF106

Evaporator Range CP216, CP217

Expander Kit CT130

F

Fan Blades CF99

Fan Motor Assembly CF98

Fan Motors CF97

FansAC44,AC46–AC50,CF99

Farm Refrigeration CP202

Fasteners CF103, CF104

Filter Fitted CP208

Fin Combs CT133

FittingsCF100–CF108

Fittings & Fasteners CF103, CF104

Fixed Speed AC12

Flange Kits IN176

Flexible Ducting AC38

Flica CV139

Float Controls IN180

Floor Console AC14

Floor Mount AC07

Floor Mounted AC06

FrascoldCC80–CC87,CP199,CP204–CP206

Free Match AC14

G

Gas Sensors IN187

Gauges CT128

Gauge Valves IN179

Geneglace CP221

Gree AC13

GreeElectricAC11–AC16

GreenleafCC63–CC65

Grills AC44

H

Hand Regulating Valves IN171

Hand Shut-Off Valves CV149

HansenIN170–IN193

Hanwest CP210

Hard Drawn Copper CT137, CT138

Heat Exchangers CH109

Heat Pump AC35

Heat Pumps AC04

Heat Transfer System AC50

Henry IN179

Hi Flow Pumps AC32

High-WallAC04,AC05,AC12–AC14

Hi Lift Pumps AC32

Horizontal Receivers CR125

HoshizakiCP218–CP220

I

IceMachinesCP218–CP221

Individual Pilot Applications IN173

Industrial Pressure Gauges IN179

In-Line Filter AC34

Inspection Mirrors CT133

InsulationCI110–CI113

Insulation Accessories CI113

Insulclamp CF107

Inverter AC05

L

Leak Detectors CT130

Level Probes IN180

Level Switch IN180

Line Tap Valves CV151

Liquid Line Assembly CP207

Liquid Receiver Valves CV148

Locksets CF108

Lubricants CL114, CL115

L’UniteCP196–CP199

L’Unite Sealed CC68, CC69, CC73

L’Unite Sealed R134a CC67

L’Unite Sealed R404a CC66

L’Unite Sealed Rotary CC72

M

Manifold Sets CT127

Marine Condenser CP210

Mastercool Tools CT130

MaxflexCI110–CI112

Maxvent AC40, AC41, AC49, AC50

MitsubishiHeavyIndustriesAC04–AC08

Mixed Flow AC46

Mixflo AC48

Mobile Model AC22

Mueller CV148, CV149

Multi AC07, AC14

Multi Head AC15

N

Neck Adapter AC42

O

Oil Control Systems CO116, CO118

Oil Drain Valves IN186

Oil Injector CT133

Oil Pump CT133

Oil Separator CO117, CP207

Oil Separators CO118

Outdoor Units AC07

P

Parker IN191

Parker Hannifin CV145

Partial Defrost CP214

Pinch Off Tool CT133

Plenums AC23

Pre-Insulated AC28

PressureControlsCP119–CP121,CP208

Pressure Pilots IN174

Pressure Regulators CV146, IN172

Pressure Relief Valves CV149

Pump Accessories IN189

R

Ranco CP119, CP120

Ratchet Wrenches CT130

Realcold CP204

Realcold Milk Vat CP202

Realpack CP201

Receivers CR124

Recovery Cylinders CT129

Recovery System CT129

RectorsealCC63–CC65

Refillable Filter CP208

Refractometers CT134

Refrigerant CR122, CR123

RefrigerantPumpAccessoriesIN189–IN190

Refrigerant Pumps IN188

Refrigeration CC79

Reversing Valve AC37

Roof Fan Kits AC45

Roof Ventilation AC45

Rotalock Valves CC73, CV148

S

Saginomiya CP119

Schrader Valves CV151

Sheet Insulation CI111

Shut-Off Valves IN179

Side Discharge AC21

Sightglass CP207

Sight Glasses CS126, IN180

Soft Drawn Copper CT138

Solenoid Coils CV144, IN191

Solenoid Valves CV144, IN186

Solid State Relays CC74

SparesSpares153–Spares166

Spares For Pumps AC35

SporlanCD90–CD93,CS126,CV140,

CV143, CV147

Sporlan J8 CV141

SteelfortCR124,CR125,CP209–CP215

Stepped Spigot AC42

Stop Check Valves IN171

Stop Valves IN171, IN186

Suction Line CP207, CP208

Supermarket Pump AC33

T

Tape CI112

Tecumseh Europe CP196

TestEquipmentCT127–CT129,CT130

Testing Equipment CT134

Thermometers CT134

Thermoplastic - Nylon CF105

ThermostaticExpansionValvesCV139–CV141

Thermostats AC36, CT135, CT136

ToolsCT130–CT133

Top Discharge AC21

Transducer Valves IN179

Tube CT137, CT138

Tube Benders CT132

Tube Cutters CT130

Tube Insulation CI110

TX Valve CV143

U

Under Ceiling AC10

Unijet AC41

Univent AC40

Universal Pump AC33

V

Vacuum Gauge CT130

Vacuum Pumps CT129

ValvesCV139–CV151

Valves-SparesIN192–IN193

Vertical Receivers CR124

Vibration Eliminators CV152

W

Wall Mount AC07

Warranty CX167, CP223

Warrenty AC51

Water Heating CP202

Weatherproof Cowl AC44

Window - Wall AC11

Notes

Notes

Branch Locations

Auckland Branch / Head Office9 Prescott Street, Penrose 1061PO Box 12072, Penrose 1642Orders Direct Line: 0800 11 66 90Orders Direct Fax: 09 526 5748Phone: 09 526 5700Fax: 09 526 5721Email: [email protected] website: www.airzonenz.co.nzRealcold website: www.realcold.co.nz

Christchurch71 Harman Street, Addington, Christchurch 8024PO Box 9150, Tower Junction, Christchurch 8149Phone: 03 338 8084 Fax: 03 338 9938Email: [email protected]

Dunedin18 Roberts Street, Dunedin 9016PO Box 2536, Dunedin 9044Phone: 03 467 7106 Fax: 03 467 7107Email: [email protected]

Hamilton43 Lake Road, Frankton, Hamilton 3204PO Box 5238, Frankton, Hamilton 3242Phone: 07 848 2111 Fax: 07 848 2333Email: [email protected]

HastingsCnr St Aubyn Street East & Miller Street Hastings 4122PO Box 488, Hastings 4156Phone: 06 870 3714 Fax: 06 870 3726Email: [email protected]

North HarbourUnit C, 28 Canaveral Drive, Albany 0632PO Box 305354, Triton PlazaNorth Shore City 0757Phone: 09 477 0274 Fax: 09 478 2309Email: [email protected]

Palmerston NorthUnit 2, 597-599 Tremaine Avenue PO Box 4368, Manawatu Mail Centre Palmerston North 4442Phone: 06 357 9101 Fax: 06 357 9103Email: [email protected]

Tauranga5 Barberry Street, Judea, Tauranga 3110PO Box 15610, Tauranga 3144Phone: 07 571 0096 Fax: 07 571 0097Email: [email protected]

Wellington54 Fitzherbert Street, Petone, Lower Hutt 5012PO Box 38527, Wellington Mail Centre Lower Hutt 5045Phone: 04 569 3072 Fax: 04 568 2210Email: [email protected]

Whangarei Unit A1, 7 - 11 Nell Place, Raumanga Whangarei 0110PO Box 25056, Whangarei Mail CentreWhangarei 0148Phone: 09 430 4476 Fax: 09 430 7465Email: [email protected]