2012catalogue product - realcold us 0800 11 66 90 dear customer, welcome to the realcold 2012...
TRANSCRIPT
Call us 0800 11 66 90www.realcold.co.nz
Dear Customer,
Welcome to the Realcold 2012 Product Catalogue. We trust you will find it a quick and easy to use reference tool. To make it even easier for you to navigate, the 2012 Catalogue includes a brand and product index, located at the back of the Catalogue.
Please give us a call if you require any additional product information or need our technical expertise. We look forward to working together in 2012.
Yours faithfully,
The Realcold Team
Air
Con
ditio
ning
Com
pone
nts
Cap
ital P
lant
Tech
nica
l Dat
aIn
dust
rial
Air ConditioningMitsubishi Heavy Industries and Gree Electric Air Conditioners and Heatpumps, Toyo Pair Coil and Trunking, PVC Drainpipe and Fittings, Aspen Condensate Pumps, Ducting and Grills, etc.
ComponentsCompressors, Controls, Driers, Fans, Insulation, Lubricants, Copper Tube and Fittings, Refrigerants, Test Equipment, Tools, Thermostats, Refrigeration, etc.
IndustrialIndustrial Refrigeration Valves, Pumps, Controls. Hansen Valves, Purgers, Level Controls, Lederle Hermetic Refrigerant Pumps, Spares, Parts Kits, etc.
Page
3Page
55Page
169
Technical Data & IndexCapacity Tables, Refrigeration Terminology, Technical Tips, Guide to Calculating Noise Levels, Metric Conversion Chart, Pressure - Temperature Data, Properties Of Refrigerants, etc.
Page
225
Product Sections
Capital PlantL’Unite Condensing Units, EasyPacks, RealPacks, Copeland Scroll Condensing Units, Custom Build, Condensors, Evaporators, Ice Machines, Chilled Water Packages, etc.
Page
195
Air
Con
ditio
ning
Air ConditioningMitsubishi Heavy Industries - Heat Pumps AC04
DXK High-Wall Split Systems AC04SRK High-Wall Split Systems High EER / COP AC05SRF Floor Mounted Split Systems AC06SCM Multi Inverter Split System AC07Cassette Split Systems AC08Ducted Split Systems - Medium & High Static AC09UNDER CEILING SPLIT SYSTEMS, ACCESSORIES AC10
Gree Electric - Heat Pumps AC11Gree Eco Window-Wall Series AC11Gree Cozy High-Wall Split Systems AC12Gree Cozy High-Wall Inverter Split Systems AC13Gree Multi Head Systems AC14Gree Multi Head Systems AC15Energy Recovery Ventilation AC16
Eclipse Air Curtains AC17
Cool Breeze Evaporative Air Conditioning AC18Down Discharge Model AC20Top Discharge Model AC21Side Discharge Model AC21Mobile Model AC22Accessories AC23Evaporative Cooling AC24
Air Conditioning Accessories AC27Mounting Brackets & Bases AC27Pre-Insulated Copper Tube AC28Ducting AC29Condensate Drain Pipe & Fittings AC30
Condensate Pumps AC32Hi Lift Pumps AC32Hi Flow Pumps AC32Universal Pump AC33Supermarket Pump AC33AC-Tabs AC33Compact Pumps - Hidden Installation AC34Compact Pumps - Below Wall Unit Installation AC35Spares For Pumps AC35
Heat Pump Accessories AC35
Electrical & Thermostats AC36Components & Fittings AC36Seitron Air Conditioning Thermostats AC36
4 Way Valves AC37Saginomiya 4-Way Reversing Valve AC37
Ducting Accessories AC38Flexible Ducting AC38Duct Fittings AC39Diffuser AC40Neck Adapter AC42Eggcrate Grille AC43Wall / Ceiling Fans / Grills AC44Roof Ventilation AC45In Line Fans AC46Transfer Fans AC50
Air Conditioning Warranty Information AC51
AC04
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DXK HIGH-WALL SPLIT SYSTEMS
Reverse Cycle Inverter High Wall - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3001-I/O DXK09Z3-S DXC09Z3-S
R410a 2.5 (1.0~2.7) 36~30~22 8,5 230/1/50 1,250.00
3.2 (1.2~4.2) 56 32
AC3002-I/O DXK12Z3-S DXC12Z3-S
R410a 3.5 (1.0~3.7) 39~32~23 8,5 230/1/50 1,500.00
4.0 (1.3~4.8) 59 35
AC3003-I/O DXK18Z3-S DXC18Z3-S
R410a 5.0 (1.6~5.5) 47~37~26 8,5 230/1/50 1,950.00
5.8 (1.6~6.6) 61 42
AC3004-I/O DXK21Z4-S DXC21Z4-S
R410a 6.3 (2.15~7.1) 44~41~36~33 15 230/1/50 2,400.00
7.1 (1.7~9.5) 62 57
AC3005-I/O DXK24Z4-S DXC24Z4-S
R410a 7.1 (2.15~8.0) 46~43~39~35 15 230/1/50 2,600.00
8.0 (1.6~10.0) 64 57
AC3006-I/O DXK28Z4-S DXC28Z4-S
R410a 8.0 (2.15~8.5) 48~45~40~37 15 230/1/50 3,000.00
9.0 (1.7~10.5) 66 57
Specifications - High-Wall Reverse Cycle - DXKDXK High Wall Series DXK09Z3-S
DXC09Z3-SDXK12Z3-SDXC12Z3-S
DXK18Z3-SDXC18Z3-S
DXK21Z4-S DXC21Z4-S
DXK24Z4-S DXC24Z4-S
DXK28Z4-S DXC28Z4-S
Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 2.5 (1.0~2.7) 3.5 (1.0~3.7) 5.0 (1.6~5.5) 6.3 (2.15~7.1) 7.1 (2.15~8.0) 8.0 (2.15~8.5)
Heating H1 3.2 (1.2~4.2) 4.0 (1.3~4.8) 5.8 (1.6~6.6) 7.1 (1.7~9.5) 8.0 (1.6~10.0) 9.0 (1.7~10.5)Input Cooling T1 kW 0.71 1.06 1.56 1.76 2.16 2.65
Heating H1 0.86 1.09 1.6 1.79 2.14 2.55Energy Label 2011 Cooling Stars 2 1.5 1.5 2.0 1.5 1.0
Heating 3 2.5 2 2.77 2.5 2.0AEER Cooling T1 3.52 3.3 3.21 3.58 3.29 3.02ACOP Heating H1 3.72 3.67 3.63 3.97 3.74 3.53Current Cooling T1 Amp 3.4 4.9 6.9 8 9.7 11.9
Heating H1 4 5 7 8.1 9.7 11.4
Recommended Circuit Breaker Amp 16 20Sound Pressure Level (JIS C9612)
Cool Ind dB 36~30~22 39~32~23 47~37~26 47~43~37~26 49~45~39~26 50~47~41~26Heat Ind 35~30~26 41~36~27 47~40~33 44~41~36~33 46~43~39~35 48~45~40~37
Sound Power Level (JIS C9612)
Outdoor dBA 56 59 61 62 66 69
Airflow Indoor L/S 133~103~75 141~113~76 183~126~78 310 325 350External Dimensions (H x W x D)
Indoor mm 268 x 790 x 224 318 x 1098 x 248Outdoor 540 x 780 (+62) x 290 640 x 800 (+71) x 290 750 x 880 (+88) x 340
Nett Weight Indoor Kg 8.5 15Outdoor 32 35 42 57
Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8") 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 0.75 1.05 1.35 1.8m 10 15
Max. Piping Length Overall/Height m 15 / 10 25 / 15 30 / 20
Features & Benefits
• New DXK**Z4 Series to meet Australian MEPS IV
• DXK21-24-28 replace the SRK**ZEA series
• Jet Air scroll, long reach and silent airflow
• 24 hour programmable function, Auto restart function
• Self clean operation
• Micro computer operated defrosting
• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52
Mitsubishi Heavy Industries - Heat Pumps
DXK High-Wall Split Systems
AC05
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
SRK HIGH-WALL SPLIT SYSTEMS HIGH EER / COP
Reverse Cycle Inverter High Wall - R410a High EER/COPRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3101-I/O SRK20ZJX-S SRC20ZJX-S
R410a 2.0 (0.9~3.1) 39~30~21 15 230/1/50 1,350.00
2.5 (0.9~4.3) 60 38
AC3102-I/O SRK25ZJX-S SRC25ZJX-S
R410a 2.55 (0.9~3.2) 41~31~22 15 230/1/50 1,650.00
3.13 (0.9~4.7) 60 38
AC3103-I/O SRK35ZJX-S SRC35ZJX-S
R410a 3.5 (0.9~4.1) 43~33~22 15 230/1/50 1,850.00
4.3 (0.9~5.1) 63 38
AC3104-I/O SRK50ZJX-S SRC50ZJX-S
R410a 5.0 (0.7~6.2) 47~40~27 15 230/1/50 2,250.00
6.0 (0.7~8.8) 62 43
AC3105-I/O SRK60ZJX-S SRC60ZJX-S
R410a 6.0 (0.8~6.8) 51~41~29 15 230/1/50 2,350.00
6.8 (0.8~9.7) 65 43
Features & Benefits
• High COP / EER
• Alergen Clear & Photocatalytic filters
• 24 hour programmable function
• Auto restart function
• Micro computer operated defrosting
• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52
Specifications - High-Wall Reverse Cycle - SRKSRK-ZJX High Wall Series SRK20ZJX-S
SRC20ZJX-SSRK25ZJX-SSRC25ZJX-S
SRK35ZJX-SSRC35ZJX-S
SRK50ZJX-SSRC50ZJX-S
SRK60ZJX-SSRC60ZJX-S
Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.0 (09~3.1) 2.55 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (0.7~6.2) 6.0 (0.8~6.8)
Heating H1 2.5 (0.9~4.3) 3.13 (0.9~4.7) 4.3 (0.9~5.1) 6.0 (0.7~8.8) 6.8 (0.8~9.7)Input Cooling T1 kW 0.35 0.49 0.845 1.3 1.86
Heating H1 0.45 0.595 0.96 1.35 1.67Energy Label 2011 Cooling Stars 6 5 3 2.5 1.5
Heating 5.5 5.5 3.5 3.5 3AEER Cooling T1 5.71 5.2 4.14 3.85 3.23ACOP Heating H1 5.56 5.26 4.48 4.44 4.07Current Cooling T1 Amp 1.8 2.4 3.8 5.7 8.2
Heating H1 2.3 2.9 4.4 5.9 7.3
Recommended Circuit Breaker Amp 16Sound Pressure Level (JIS C9612)
Cool Ind dB 39~30~21 41~31~22 43~33~22 47~40~27 51~41~29Heat Ind 38~33~25 41~34~27 42~35~27 48~40~33 48~41~34
Sound Power Level (JIS C9612)
Outdoor dBA 60 60 63 62 65
Airflow Indoor L/S 191~133~83 208~150~83 225~158~83 225~183~133 241~208~141External Dimensions (H x W x D)
Indoor mm 309 x 890 x 220Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290
Nett Weight Indoor Kg 15Outdoor 38 43
Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8”) 12.7 (1/2”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 1.2 1.4m Pre-charged for 15m of field piping
Max. Piping Length Overall/Height m 15 / 10 30 / 20
SRK High-Wall Split Systems High EER / COP
AC06
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
SRF FLOOR MOUNTED SPLIT SYSTEMS
Reverse Cycle Inverter Floor Mounted - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3201-I/O SRF25ZJX-S SRC25ZJX-S
R410a 2.5 (0.9~3.2) 38~31~26 18 230/1/50 2,200.00
3.4 (0.9~4.7) 60 38
AC3202-I/O SRF35ZJX-S SRC35ZJX-S
R410a 3.5 (0.9~4.1) 41~34~28 19 230/1/50 2,500.00
4.5 (0.9~5.1) 63 38
AC3203-I/O SRF50ZJX-S SRC50ZIX-S
R410a 5.0 (0.7~5.5) 46~42~32 19 230/1/50 2,800.00
6.0 (0.7~7.0) 62 43
Features & Benefits
• Hi Power
• Enzyme & Photocatalytic filters
• 24 hour programmable function
• Upper and Lower air outlet selection
• Micro computer operated defrosting
• Auto restart
• 5 Year Warranty on Parts and Labour only - for full Warranty information refer to page AC52
Specifications - Reverse Cycle Floor Mounted - SRFSRF Floor Mounted Series SRF25ZJX-S
SRC25ZJX-SSRF35ZJX-SSRC35ZJX-S
SRF50ZJX-SSRC50ZI X-S
Power Supply Outdoor Unit 1 phase 230V 50Hz
Capacity Cooling T1 kW 2.5 (0.9~3.2) 3.5 (0.9~4.1) 5.0 (0.7~5.5)
Heating H1 3.4 (0.9~4.7) 4.5 (0.9~5.1) 6.0 (0.7~7.0)
Input Cooling T1 kW 0.521 0.89 1.39
Heating H1 0.723 1.124 1.54
Energy Label 2011 Cooling Stars 4 2.5 2
Heating 4 3 2.5
AEER Cooling T1 4.8 3.93 3.6
ACOP Heating H1 4.7 4 3.9
Current Cooling T1 Amp 2.5 3.9 6.1
Heating H1 3.4 4.9 6.8
Recommended Circuit Breaker Amp 16
Sound Pressure Level (JIS C9612)
Cool Ind dB 38~31~26 41~34~28 46~42~32
Heat Ind 38~34~28 41~36~31 47~41~33
Sound Power Level (JIS C9612)
Outdoor dBA 60 63 62
Airflow Indoor L/S 150~126~96 153~130~106 191~160~110
External Dimensions (H x W x D)
Indoor mm 600 x 860 x 238
Outdoor 595 x 780 (+62) x 290 640 x 800 (+71) x 290
Nett Weight Indoor Kg 18 19
Outdoor 38 43
Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)
Gas Line 9.52 (3/8”) 12.7 (1/2”)
Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 1.2 1.4
m Pre-charged for 15m of field piping
Max. Piping Length Overall/Height m 15 / 10 30 / 20
SRF Floor Mounted Split Systems
AC07
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
SCM MULTI INVERTER SPLIT SYSTEM
Reverse Cycle Inverter Outdoor Units - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
No of Rooms Max kW Cooling Connect
Largest Indoor Connect
ElectricSupply
System Price$ Excl. GST
AC3301 SCM40ZJ-S R410a 4.0 (1.8~5.9) 2 rooms 6.0kW 3.5kW 230/1/50 2,300.00
4.5 (1.4~6.9)
AC3302 SCM50ZJ-S R410a 5.0 (1.8~7.1) 2~3 rooms 8.5kW 5.0kW 230/1/50 2,750.00
6.0 (1.4~7.5)
AC3303 SCM60ZJ-S R410a 6.0 (1.8~7.5) 2~3 rooms 11.0kW 6.0kW 230/1/50 3,000.00
6.8 (1.5~7.8)
AC3304 SCM71ZJ-S R410a 7.1 (1.8~8.8) 2~4 rooms 12.5kW 6.0kW 230/1/50 3,500.00
8.6 (1.5~9.4)
AC3305 SCM80ZJ-S R410a 8.0 (1.8~9.2) 2~4 rooms 13.5kW 6.0kW 230/1/50 3,850.00
9.3 (1.5~9.8)
Multi Indoor Units - Wall MountRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
System Price$ Excl. GST
AC3311 SRK20ZJ R410a 2.0/2.7 294 x 798 x 229 130 33/27/21 230/1/50 400.00
AC3312 SRK25ZJ R410a 2.5/3.2 295 x 798 x 229 131 34/28/21 230/1/50 432.00
AC3313 SRK35ZJ R410a 3.5/4.0 296 x 798 x 229 168 42/32/22 230/1/50 496.00
AC3314 SRK50ZJ R410a 5.0/5.8 297 x 798 x 229 188 46/37/26 230/1/50 640.00
AC3321 SRK20ZJX R410a 2.0/2.5 309 x 890 x 220 191 39/30/21 230/1/50 432.00
AC3322 SRK25ZJX R410a 2.5/3.1 309 x 890 x 220 208 41/31/22 230/1/50 528.00
AC3323 SRK35ZJX R410a 3.5/4.5 309 x 890 x 220 225 43/33/22 230/1/50 592.00
AC3324 SRK50ZJX R410a 5.0/5.8 309 x 890 x 220 225 47/40/27 230/1/50 720.00
AC3325 SRK60ZJX R410a 6.0/6.8 309 x 890 x 220 241 51/41/29 230/1/50 752.00
Multi Indoor Units - CassetteRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
System Price$ Excl. GST
AC3331 FDTC25Z R410a 2.5/3.4 248 x 570 x 570 150 36/32/29 230/1/50 POA
AC3332 FDTC35Z R410a 3.5/4.5 248 x 570 x 570 158 40/36/30 230/1/50 POA
AC3333 FDTC50Z R410a 5.0/5.8 248 x 570 x 570 192 42/36/30 230/1/50 POA
AC3334 FDTC60Z R410a 6.0/6.8 248 x 570 x 570 225 46/39/30 230/1/50 POA
Multi Indoor Units - Bulk Head (low static)RealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
System Price$ Excl. GST
AC3341 SRR25ZJ R410a 2.5/3.4 230 x 740 x 455 142 40/35/29 230/1/50 900.00
AC3342 SRR35ZJ R410a 3.5/4.5 230 x 740 x 455 150 42/37/30 230/1/50 1,000.00
AC3343 SRR50ZJ R410a 5.0/5.8 230 x 740 x 455 175 48/42/33 230/1/50 1,150.00
AC3344 SRR60ZJ R410a 6.0/6.8 230 x 740 x 455 208 51/44/35 230/1/50 1,250.00
Multi Indoor Units - Floor MountRealcoldStock No.
MitsubishiModel No.
Refrigerant Nominal Cap kW Cool / Heat
DimensionsH x W x D
Airflow Max L/S
Ind Sound dBA
ElectricSupply
System Price$ Excl. GST
AC3351 SRF25ZJX R410a 2.5/3.4 600 x 860 x 238 150 40/32/26 230/1/50 1,078.00
AC3352 SRF35ZJX R410a 3.5/4.5 600 x 860 x 238 153 41/34/28 230/1/50 1,242.00
AC3353 SRF50ZJX R410a 5.0/5.8 600 x 860 x 238 191 46/42/32 230/1/50 1,270.00
SCM Multi Inverter Split System
AC08
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
CASSETTE SPLIT SYSTEMS
Reverse Cycle Inverter Cassette - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3401 FDTC50ZIXVD R410a 5.0 (2.2~5.6) 47~42~36~32 18.5 230/1/50 3,500.00
5.4 (2.5~6.3) 47 43
AC3402 FDT60ZIXVD R410a 5.6 (2.8~6.3) 46~33~31~30 29.5 230/1/50 3,750.00
6.7 (3.1~7.1) 48 43
AC3403 FDT71VNXVD R410a 7.1 (3.2~8.0) 46~35~33~31 29.5 230/1/50 4,750.00
8.0 (3.6~9.0) 51 60
AC3404 FDT100VNVD R410a 10.0 (4.0~11.2) 51~40~37~35 32.5 230/1/50 5,850.00
11.2 (4.0~12.5) 49 81
AC3405 FDT125VNXVD R410a 12.5 (5.0~14.0) 51~42~40~37 32.5 230/1/50 6,500.00
14.0 (4.0~17.0) 50 105
AC3406 FDT140VNXVD R410a 14.0 (5.0~16.0) 51~43~41~38 32.5 230/1/50 6,950.00
16.0 (4.0~18.0) 52 105
Note: Available in both wired control and Infra Red Control. Please specify Wired or Infra Red Control at time of order. Wired Control = RC-E4; Infra Red Control = RCN-T-36W-E
Features & Benefits
• Individual flap control
• Thin design, High efficiency
• Available in both Wired Control and Infra Red Control. Please specify Wired or Infra Red Control at time of order
• Wired Control; All RC-E4, Infra Red Control; FDT60, FDT140, RCN-T-36W-E & FDTC50, RCN-TC-24W-E
• CnT terminal to allow easy connection to BMS, home automation and external timers
Specifications - Reverse Cycle Inverter CassetteFDTC & FDT Cassette Series FDTC50ZIXVD
SRC50ZIX-S FDTC50VD
FDT60ZIXVDSRC60ZIX-S FDT60VD
FDT71VNXVDFDT71VNX FDT71VD
FDT100VNVDFDT100VN FDT100VD
FDT125VNXVDFDT125VNX FDT125VD
FDT140VNXVDFDT140VNX FDT140VD
Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)
Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 1.56 1.57 2.04 2.76 3.28 4.19
Heating H1 1.45 1.85 1.94 2.74 3.43 4.20Energy Label 2011 Cooling Stars 2 2.5 1.5 1.5 2.0 1.5
Heating 2.5 2.5 3.0 3.0 3.0 2.5AEER Cooling T1 3.21 3.57 3.48 3.62 3.81 3.34ACOP Heating H1 3.72 3.62 4.12 4.08 4.08 3.81Current Cooling T1 Amp 6.9 7.0 9.1 12.1 14.6 18.6
Heating H1 6.4 8.2 8.7 12.0 15.2 18.6
Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)
Cool Ind dB 47~42~36~32 46~33~31~30 46~35~33~31 51~40~37~35 51~42~40~37 51~43~41~38Heat Ind 47 48 51 49 50 52
Sound Power Level (JIS C9612)
Outdoor dBA 62 65 66 70 70 72
Airflow Indoor L/S 225~191~150~133 466~300~266~233 466~350~316~283 616~450~400~333 616~500~450~383 616~500~450~383
Panel T-PSA-3AW-E mm 35 x 700 x 700 35 x 950 x 950External Dimensions (H x W x D)
Indoor mm 248 x 570 x 570 246 x 840 x 840 298 x 840 x 840Outdoor 640 x 872 x 290 750 x 880 x 340 845 x 970 x 410 1300 x 970 x 370
Nett Weight Indoor Kg 18.5 29.5 32.5Outdoor 43 60 81 105
Refrigerant Piping Liquid Line mm (in)
6.35 (1/4”) 9.52 (3/8”)Gas Line 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 1.4 2.95 3.8 4.5m 15 30
Max. Piping Length Overall/Height m 30/20 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-TC-24W-ER or RCN-T-36W-E
Cassette Split Systems
AC09
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DUCTED SPLIT SYSTEMS - MEDIUM & HIGH STATIC
Reverse Cycle Inverter Ducted - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3601 FDUM50ZIXVD R410a 5.0 (2.2~5.6) 35~34~31~28 34 230/1/50 2,850.00
5.4 (2.5~6.3) 47 43
AC3602 FDUM60ZIXVD R410a 5.6 (2.8~6.3) 38~34~31~28 40 230/1/50 3,200.00
6.7 (3.1~7.1) 48 43
AC3603 FDU71VNXVD R410a 7.1 (3.2~8.0) 41~37 40 230/1/50 4,250.00
8.0 (3.6~9.0) 51 60
AC3604 FDU100VNVD R410a 10.0 (4.0~11.2) 42~37 63 230/1/50 4,900.00
11.2 (4.0~12.5) 49 81
AC3605 FDU125VNXVD R410a 12.5 (5.0~14.0) 43~38 63 230/1/50 5,600.00
14.0 (4.0~17.0) 50 105
AC3606 FDU140VNXVD R410a 14.0 (5.0~16.0) 43~38 63 230/1/50 6,800.00
16.0 (4.0~18.0) 52 105
Features & Benefits
• Quiet, lightweight and compact
• Selectable static pressure, 600 mm drain pump fitted
• Available in both wired control and Infra Red Control. Please specify Wired or Infra Red Control at time of order
• Wired Control, RC-E4. Infra Red Control, RCN-Kit3-E
• CnT terminal to allow easy connection to BMS, home automation and external timers
Specifications - Reverse Cycle Inverter DuctedFDUM & FDU Ducted Medium Static Series FDUM50ZIXVD
SRC50ZIX-S FDUM50VD
FDUM60ZIXVDSRC60ZIX-S FDUM60VD
FDU71VNXVDFDU71VNX FDU71VD
FDU100VNVDFDU100VN FDU100VD
FDU125VNXVDFDU125VNX FDU125VD
FDU140VNXVDFDU140VNX FDU140VD
Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 5.0 (2.2~5.6) 5.6 (2.8~6.3) 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)
Heating H1 5.4 (2.5~6.3) 6.7 (3.1~7.1) 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 1.52 1.86 2.15 2.88 3.44 4.2
Heating H1 1.41 1.96 2.15 2.99 3.67 4.3Energy Label 2011 Cooling Stars 2 2 2 2 2 1.5
Heating 3 2 2.5 2.5 3 2.5EER Cooling T1 3.29 3.01 3.3 3.47 3.63 3.33COP Heating H1 3.82 3.42 3.72 3.74 3.81 3.72Current Cooling T1 Amp 6.7 8.2 9.6 12.7 15.3 18.6
Heating H1 6.3 9.0 9.5 13.1 16.3 19.1
Recommended Circuit Breaker Amp 16 20 32Sound Pressure Level (JIS C9612)
Cool Ind dB 35~34~31~28 38~34~31~28 41~37 42~37 43~38Heat Ind 47 48 51 49 50 52
Sound Power Level (JIS C9612)
Outdoor dBA 62 65 66 70 72
Airflow Indoor L/S 233~216~200~183 300~266~250~233 333 ~ 283 566 ~ 450 700 ~ 558External Static Pressure
Indoor Pa 85 @ 233 l/s 85 @ 300 l/s 60/130 @ 333 l/s 60/130 @ 566 l/s 60/130 @ 700 l/s
External Dimensions (H x W x D)
Indoor mm 299 x 750 x 635 299 x 950 x 635 297 x 850 x 650 350 x 1370 x 650Outdoor 640 x 872 x 290 750 x 968 x 340 845 x 970 x 370 1300 x 970 x 370
Nett Weight Indoor Kg 34 40 40 63Outdoor 43 60 81 105
Refrigerant Piping Liquid Line mm (in)
6.35 (1/4") 9.52 (3/8”)Gas Line 12.7 (1/2") 15.88 (5/8”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 1.4 2.95 3.8 4.5m 15 30
Max. Piping Length Overall/Height m 30/20 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-KIT3-E
Ducted Split Systems - Medium & High Static
AC10
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
UNDER CEILING SPLIT SYSTEMS, ACCESSORIES
Reverse Cycle Inverter Under Ceiling - R410aRealcoldStock No.
MitsubishiModel No.
Refrigerant Cap kW T1 Nominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC3701 FDEN71VNXVD R410a 7.1 (3.2~8.0) 50~41~39~38 37 230/1/50 4,600.008.0 (3.6~9.0) 51 60
AC3702 FDEN100VNVD R410a 10.0 (4.0~11.2) 46~44~41~39 49 230/1/50 5,800.0011.2 (4.0~12.5) 49 81
AC3703 FDEN125VNXVD R410a 12.5 (5.0~14.0) 50~46~44~43 49 230/1/50 6,400.0014.0 (4.0~17.0) 50 105
AC3704 FDEN140VNXVD R410a 14.0 (5.0~16.0) 50~46~44~43 49 230/1/50 6,990.0016.0 (4.0~18.0) 52 105
Specifications - Reverse Cycle Inverter Under CeilingFDEN Under Ceiling Series FDEN71VNXVD
FDC71VNX FDEN71VD
FDEN100VNVDFDC100VN FDEN100VD
FDEN125VNXVDFDC125VNXFDEN125VD
FDEN140VNXVDFDC140VNXFDEN140VD
Power Supply 1 phase 230V 50Hz Indoor Unit Outdoor UnitCapacity Cooling T1 kW 7.1 (3.2~8.0) 10.0 (4.0~11.2) 12.5 (5.0~14.0) 14.0 (5.0~16.0)
Heating H1 8.0 (3.6~9.0) 11.2 (4.0~12.5) 14.0 (4.0~17.0) 16.0 (4.0~18.0)Input Cooling T1 kW 2.11 2.85 3.86 4.98
Heating H1 2.11 2.97 3.77 4.69Energy Label 2011 Cooling Stars 1 2 1 0.5
Heating 2 2.5 2 1.5AEER Cooling T1 3.36 3.51 3.23 2.81ACOP Heating H1 3.79 3.77 3.71 3.41Current Cooling T1 Amp 9.1 12.5 17.1 22.1
Heating H1 9.1 13.0 16.7 20.8
Recommended Circuit Breaker Amp 20 32Sound Pressure Level (JIS C9612)
Cool Ind dB 50~41~39~38 46~44~41~39 50~46~44~43Heat Ind 51 49 50 52
Sound Power Level (JIS C9612)
Outdoor dBA 66 70 70 72
Airflow Indoor L/S 366~300~233~200 466~433~383~350 533~483~433~383External Dimensions (H x W x D)
Indoor mm 210 x 1320 x 690 250 x 1620 x 690Outdoor 750 x 968 x 340 845 x 970 x 370 1300 x 970 x 370
Nett Weight Indoor Kg 37 49Outdoor 60 81 105
Refrigerant Piping Liquid Line mm (in)
9.52 (3/8")Gas Line 15.88 (5/8")Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 2.95 3.8 4.5m 30
Max. Piping Length Overall/Height m 50/+30 -15 100/+30 -15Controller RC-E4 or RCN-E-E
Mitsubishi Heat Pump AccessoriesRealcoldStock No.
MitsubishiModel No.
Description System Price$ Excl. GST
AC3901 RCN-KIT3-E Infra red kit for FDU/M 296.00AC3902 RC-E4 Wired Remote controller for all indoor units 140.00AC3903 RCH-E3 Simple wired remote control - 2 wire 180.00AC3904 SC-ADNA-E Superlink adaptor for SRK and FD (RC-E4) 210.00AC3905 CnT Card connector flying leads 25.00AC3906 SC-THB-E3 Remote sensor 91.00AC3907 CW-H-E Base Heater kit for FDC125VNX and FDC140VNX POAAC3908 PCA006A057B PC Mente Interface 400.00AC3910 SC-BIKN-E Interface PCB for SRK and FD (RC-E4) 125.00
UNDER CEILING SPLIT SYSTEMS, ACCESSORIES
AC11
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
GREE ECO WINDOW-WALL SERIES
THE PROFESSIONAL’S CHOICE
Reverse Cycle Window - Wall - R410aRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Noise dBAHigh/Low
Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5015 GJH09AB-K3MNB8A R410a 2.7 49 43 230/1/50 615.00
2.4 45
AC5016 GJH12AD-K3MNB8A R410a 3.5 53 54 230/1/50 740.00
3 49
AC5017 GJH18AC-K3MNB8A R410a 5 55 73 230/1/50 890.00
4.7 51
AC5018 GJH24AC-K3MNB8A R410a 6.2 58 75 230/1/50 1,025.00
6 53
Features & Benefits
• Exceeds the 2011 MEPS III annulised ratings
• R410a Refrigerant
• 4 Way Air Flow
• Easy Clean Filter
• 5 Year Parts and Labour Warranty, domestic use only
• 4WayAirFlow • Longdistanceairing
• EasyCleanedFilter• EconomicSleepMode
Specifications - Gree ECO Window-Wall SeriesGree ECO Window-Wall Series GJH09AB-K3MNB8A GJH12AD-K3MNB8A GJH18AC-K3MNB8A GJH24AC-K3MNB8A
Power Supply Outdoor Unit 1 phase 230V 50Hz
Capacity Cooling T1 kW 2.7 3.5 5 6.2
Heating T1 2.4 3 4.7 6
Input Cooling T1 kW 0.9 1.25 1.75 2.05
Heating T1 0.8 1 1.56 1.75
Energy Label 2011 Cooling Stars 1 1 1.5 1.5
Heating 1.5 1.5 1.5 1.5
AEER Cooling T1 3 2.9 2.9 3.02
ACOP Heating T1 3 2.9 2.9 3.43
Current Cooling T1 Amp 4.83 6.5 10.5 13
Recommended Circuit Breaker Amp 16 20
Sound Pressure Level (JIS C9612)
High dBA 49 53 55 58
Low 45 49 51 53
Airflow Indoor L/S 138 216 230 250
External Dimensions (H x W x D)
Indoor mm 375 x 560 x 618 428 x 660 x 700
Nett Weight Kg 43 54 73 75
Refrigerant R410a Pre-charged Kg 0.78 0.81 1.07 1.4
Gree Eco Window-Wall Series
Gree Electric - Heat Pumps
AC12
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
GREE COZY HIGH-WALL SPLIT SYSTEMS
THE PROFESSIONAL’S CHOICE
Fixed Speed - R410aRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC5452G/W GWH09MB-K3NNA*B R410a 2.74 32 10 230/1/50 750.00
2.85 50 40
AC5454G/W GWH12MB-K3NNA*B R410a 3.38 32 10 230/1/50 850.00
3.26 52 41
AC5456G/W GWH18MC-K3NNA*B R410a 5.28 38 13 230/1/50 1,190.00
5.7 54 46
AC5458G/W GWH24MD-K3NNA*B R410a 6.15 46 15.5 230/1/50 1,490.00
6.75 58 64
Features & Benefits
• Fixed speed heat pumps are a viable alternative to expensive and complicated inverter air conditioners
• With over a three to one ratio, fixed speed heat pumps are an energy efficient way of heating your home
• Exceeds the 2011 MEPS III annulised ratings
• 5 metre connection cable included
• Healthy filter options
• 5 Year Parts and Labour Warranty, domestic use only
• ActiveCarbonFilter• High-efficientcurved heat exchanger
• SuperQuietOperation • EasyCleanFlatPanel
Specifications - Gree Cozy High-Wall Split SystemsGree Cozy High-Wall Split Systems GWH09MB-K3NNA*B GWH12MB-K3NNA*B GWH18MC-K3NNA*B GWH24MD-K3NNA*B
Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.74 3.38 5.28 6.15
Heating T1 2.85 3.26 5.7 6.75Input Cooling T1 kW 0.8 0.99 1.7 2.04
Heating T1 0.84 0.97 1.85 2.23Energy Label 2011 Cooling Stars 2 2 1.5 1.5
Heating 2 2 1.5 1.5AEER Cooling T1 3.42 3.41 3 3.01ACOP Heating T1 3.39 3.36 3.17 3.03Current Cooling T1 Amp 3.82 4.29 8.29 9.81Recommended Circuit Breaker Amp 10 16 20Moisture Removal L/H 2.5 2.5 3 4Sound Pressure Level (JIS C9612)
Indoor dBA 32 32 38 46Outdoor 50 52 54 58
Airflow Indoor L/S 167 167 217 222External Dimensions (H x W x D)
Indoor mm 275 x 845 x 180 298 x 940 x 200 315 x 1,007 x 219Outdoor 540 x 780 x 320 592 x 780 x 320 680 x 846 x 378 790 x 920 x 427
Nett Weight Indoor Kg 10 13 15.5Outdoor 40 41 46 64
Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 9.52 (3/8”) 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 1.23 1.02 1.55 2.1m 5 5 5 5
Max. Piping Length Overall/Height m 15 20 25
Gree Cozy High-Wall Split Systems
AC13
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
GREE COZY HIGH-WALL INVERTER SPLIT SYSTEMS
THE PROFESSIONAL’S CHOICE
Reverse Cycle Inverter High-Wall - R410aRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal~Range
Noise dBAIND/OUT
Weight (Kg)IND/OUT
ElectricSupply
System Price$ Excl. GST
AC7170G/W GWH09MB-K3DNA*H R410a 2.5 (0.35~3) 40~32 9 230/1/50 1,050.00
2.8 (0.75~3.5) 50 35
AC7171G/W GWH12MB-K3DNA*H R410a 3.5 (0.95~4) 42~33 11 230/1/50 1,250.00
3.85 (0.88~4.3) 52 36
AC7172G/W GWH18MC-K3DNA*H R410a 5 (1.26~6.15) 49~35 13 230/1/50 1,550.00
5.56 (1.12~6.3) 52 47
AC7173G/W GWH24MD-K3DNA*H R410a 6.3 (1.4~6.8) 46~33 16 230/1/50 1,750.00
6.76 (1.2~8) 54 50
AC7174G/W GWH24ME-K3DNA*H R410a 7.2 (1.4~8.7) 47~40 17,5 230/1/50 1,990.00
8.2 (1.05~10) 59 65
Features & Benefits
• New 180 Deg Sine Wave Inverter
• Lowest Energy Consumption
• Ultra Low Noise
• Exceeds the 2011 MEPS III annulised ratings
• 5 metre connection cable included
• Healthy filter options
• 5 Year Parts and Labour Warranty, domestic use only
• ActiveCarbonFilter• High-efficientcurved heat exchanger
• SuperQuietOperation • EasyCleanFlatPanel
Specifications - Gree Cozy High-Wall Inverter Split SystemsGree Cozy High-Wall Inverter Split Systems GWH09MB-
K3DNA*HGWH12MB-K3DNA*H
GWH18MC-K3DNA*H
GWH24MD-K3DNA*H
GWH24ME-K3DNA*H
Power Supply Outdoor Unit 1 phase 230V 50HzCapacity Cooling T1 kW 2.6 (0.35~3) 3.5 (0.95~4) 5.2 (1.26~6.15) 6.3 (1.4~6.8) 8 (1.4~8.7)
Heating T1 2.8 (0.75~3.5) 3.85 (0.88~4.3) 5.8 (1.12~6.3) 6.3 (1.2~8) 8.4 (1.05~10)Input Cooling T1 kW 0.73 0.98 1.59 1.93 2.46
Heating T1 0.78 1.07 1.79 1.93 2.55Energy Label 2011 Cooling Stars 2.5 2.5 1.5 1.5 1.5
Heating 2.5 2.5 1.5 1.5 1.5AEER Cooling T1 3.55 3.56 3.24 3.24 3.23ACOP Heating T1 3.57 3.59 3.24 3.24 3.27Current Cooling T1 Amp 3.26 4.43 6.9 8.8 10.8Recommended Circuit Breaker Amp 10 15 20Moisture Removal L/H 1 1.4 2 2.5 2.5Sound Pressure Level (JIS C9612)
Indoor dBA 32 33 35 33 40Outdoor 50 52 54 59
Airflow Indoor L/S 137 163 236 250 320External Dimensions (H x W x D)
Indoor mm 265 x 790 x 170 370 x 918 x 258 298 x 940 x 200 315 x 1,008 x 219 326 x 1,178 x 253Outdoor 540 x 776 x 320 595 x 881 x 363 700 x 955 x 424 700 x 955 x 424 790 x 920 x 427
Nett Weight Indoor Kg 9 11 13 16 17.5Outdoor 35 36 47 50 65
Refrigerant Piping Liquid Line mm (in) 6.35 (1/4”)Gas Line 6.35 (1/4”) 12.7 (1/2”) 15.88 (5/8”)Conn Method Flare
Refrigerant R410a Pre-charged amount
Kg 0.8 1.15 1.1 1.4 1.8m 5 5 5 5 7.5
Max. Piping Length Overall/Height m 20 30
Gree Cozy High-Wall Inverter Split Systems
AC14
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
GREE MULTI HEAD SYSTEMS
THE PROFESSIONAL’S CHOICE
Inverter Free Match - Multi Outdoor UnitsRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Min ~ Max No of Heads Noise dBAOUT
Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5274 GWHD(24)NK3AO R410a C7.1 C2.9~8.3 2 58 68 230/1/50 2,390.00
H8.5 H1.6~9.8 59
AC5276 GWHD(24)NK3CO R410a C7.1 C2.7~10 2 ~ 3 54 75 230/1/50 2,790.00
H8.5 H2.8~11 60
DC Inverter Free Match - Trendy High-Wall SeriesRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Ind dBA Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5250 GWHD(07)BANK3A1AI R410a C2.1 28~37 8.5 230/1/50 340.00
H2.5
AC5252 GWHD(09)BANK3A1AI R410a C2.5 28~38 8.5 230/1/50 380.00
H3.2
AC5254 GWHD(12)BBNK3A1AI R410a C3.5 30~40 11 230/1/50 420.00
H3.9
AC5256 GWHD(18)BCNK3A1AI R410a C5.0 36~46 13 230/1/50 490.00
H5.7
Ducted Series - Low Static Bulk HeadRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Ind dBA Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5260 GFHD(09)AANK3A1AI R410a C2.5 30~37 27 230/1/50 550.00
H3.2
AC5261 GFHD(12)AANK3A1AI R410a C3.5 33~40 27 230/1/50 650.00
H3.9
AC5263 GFHD(18)AANK3A1AI R410a C5.0 33~42 36 230/1/50 750.00
H5.7
Floor Console SeriesRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Ind dBA Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5265 GTHD(09)AANK3A1AI R410a C2.5 32~45 27 230/1/50 560.00
H3.2
AC5266 GTHD(12)AANK3A1AI R410a C3.5 36~46 27 230/1/50 595.00
H3.9
AC5267 GTHD(18)AANK3A1AI R410a C5.0 47~54 27 230/1/50 650.00
H5.7
Cassette SeriesRealcoldStock No.
GreeModel No.
Refrigerant Cap kWNominal
Ind dBA Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC5268 GKHD(12)ABNK3A2AI R410a C3.5 36~44 20 230/1/50 890.00
H3.9
AC5269 GKHD(18)ABNK3A2AI R410a C5.0 39~47 20 230/1/50 990.00
H5.7
Gree Multi Head Systems
AC15
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
GREE MULTI HEAD SYSTEMS
Allowable ConnectionsTwin Head Triple Head
Model GWHD(24)NK3AO GWHD(24)NK3CO
Nominal Capacity C7.0/ H8.7 C7.1/ H8.5
Total Combined Capacity C8.3/ H9.8 C10.0/ H11.0
Total Pipe Length/ Height 20/ 5 70/ 10
Recommended Match Plan for Indoor and Outdoor UnitsGWHD(24)NK3AO ~ 1 to 2 indoor units ~ 9 combinations
1 indoor unit 2 indoor units 3 indoor units
7 7 + 7 9 + 9
NONE9 7 + 9 9 + 12
12 7 + 12 12 + 12
GWHD(24)NK3CO ~ 2 to 3 indoor units ~ 24 combinations
1 indoor unit 2 indoor units 3 indoor units
NONE
7 + 7 9 + 9 7 + 7 + 7 7 + 9 + 12 9 + 9 + 9
7 + 9 9 + 12 7 + 7 + 9 7 + 9 + 18 9 + 9 + 12
7 + 12 9 + 18 7 + 7 + 12 7 + 12 + 12 9 + 9 + 18
7 + 18 12 + 12 7 + 7 + 18 7 + 12 + 18 9 + 12 +12
12 + 18 7 + 9 + 9 9 + 12 + 18 12 + 12 +18
kW Model Type 2.1 / 2.5 2.5 / 3.2 3.5 / 3.9 5.0 / 5.7
Hi-wall
Ducted
Floor
Cassette
THE PROFESSIONAL’S CHOICE
Gree Multi Head Systems
AC16
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
ENERGY RECOVERY VENTILATION
THE PROFESSIONAL’S CHOICE
RealcoldStock No.
GreeModel No.
Airflow (m3/hr) Max. External Static Pressure
ElectricSupply
System Price$ Excl. GST
AC5322 FHBQ-D3.5-K
H 350
100
220V~1Ph~50Hz
POAM 260
L 210
AC5324 FHBQ-D5-K
H 500
100 POAM 380
L 300
AC5326 FHBQ-D8-K
H 800
110 POAM 600
L 480
AC5328 FHBQ-D10-K
H 1000
110 POAM 750
L 600
AC5330 FHBQ-D15-M 1500 150 150
380V ~ 3Ph ~50Hz
POA
AC5332 FHBQ-D20-M 2000 150 150 POA
AC5334 FHBQ-D30-M 3000 220 220 POA
Accessories
• All units come with a simplified wired controller. Humidity Sensor Optional.
Gree Energy - Recovery Ventilation Systems
This Energy-Recovery Ventilation Systems supplies modulated fresh air to improve the indoor air quality. The high heat exchange efficiency offers up to 70% temperature exchange efficiency. Heat recovery ventilation systems can reduce the loading on air conditioners / heat pumps by 26%, based on annual operation.
• High Heat Exchanger Efficiency
• Remarkable Energy Savings
• 7 models available from 97 - 833 l/s
• Flexible Control Functions
o 50 - 50 air discharge / supply
o Positive or negative room pressure
o Weekly control for on - off timer
o Humidity control (optional)
o Centralized Remote Control (optional)
• Long Distance Control (optional)
• Easy installation & maintenance
• Long life and washable filters and heat exchanger
Energy Recovery Ventilation
AC17
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CURTAINS
Eclipse Air CurtainsRealcoldStock No.
EclipseModel No.
Length (mm) Fan Diameter (mm)
Input Power Watts
Air Speed (m/sec)
Noise dBA Weight (Kg) ElectricSupply
System Price$ Excl. GST
AC7500 FM-1.25-09 900 125 130 8 60 20 230/1/50 567.00
AC7501 FM-1.25-12 1200 125 170 8 60 24 230/1/50 613.00
AC7502 RM-1.5-09D 900 150 6300 7 64 26 230/1/50 1,025.00
Specifications - Air CurtainsFM-1.25-09 FM-1.25-12 RM-1.5-09D
Cabinet Dimensions (mm) 900 x 215 x 193 1200 x 215 x 193 900 x 383 x 266
Min Install Height 2.5m 2.5m 3.5m
Max Install Height 3.0m 3.0m 4.0m
Remote No No Yes
Electric Heater No No Yes
Features & Benefits
• Adjustable air fins allow for the exact control of air for special applications such as sloping walls and cross winds.
• Front Return Air Grille.
• 2 Speed Fans.
• Operating Temperature range -15 to +50 ˚C.
• 125mmm & 150mm Diameter Fan.
• Easy Mounting System.
• Remote Control on heating model.
• 12 months warranty on parts only.
Air Cutains - The New Advantage in the Energy Battle
• Energy Savings: Recent studies have shown that by fitting an air curtain will save significant amounts of energy by providing environmental seperation between indoor and outdoor temperatures. Pay back for some commercial appliactions can be as little as 21 weeks.
• Improved Indoor Air Quality: Air curtains prevent dust, dirt and fumes from infiltrating and contaminating indoor areas.
• Lower Construction Costs: With the use of air curtains Architects can design building without vestibules, saving construction costs and by eliminating the vestibule, providing more retail floor space.
• Improved Working Conditions: Keeps out cold air at door openings and recirculates warm air from ceiling to floor for more comfortable working conditions.
Eclipse Air Curtains
AC18
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING
Evaporative Air Conditioning - Cool Breeze
Cool Breeze is the smart choice for top FRESH air conditioning performance & the best value for money system around.
Cool Breeze Evaporative Air Conditioning
AC19
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING
Evaporative Air Conditioning - Cool Breeze
Cool Breeze evaporative air conditioning is the natural healthy way to cool your office, factory, showroom, warehouse or home.
Unlike refrigerated air conditioning systems where air is dried, chilled and re-circulated, a Cool Breeze evaporative system uses the natural element of water to cool the air. The air is always fresh because stale air is continually expelled through open doors and windows.
This technology, although enjoying enormous growth, is still largely underutilized and unknown in many parts of the world. EAC can provide cooling and ventilation with minimum energy consump-tion and without the use of ozone depleting chemicals such as CFC’s and HFC’s.
The principle of EAC is simple and commonly found in nature. For example, warm air passing over the ocean is cooled through the evaporative process before it reaches the mainland. This occurs because the warm air causes the water to evaporate and as the water evaporates, it absorbs the heat from the warm air, thereby cooling it.
In a modern evaporative air conditioner water is pumped from the base of the cooler onto the top of the pads. The important function of the fan is to draw air from the outside through the moisture laden filter pads, and then force the cooled air into the ductwork to be distributed into the building. It is therefore important to have some openings, such as doors or windows, sufficiently open to allow all the air in the building to escape.
Evaporative Cooler Selection Formula
Room Volume x 25 Air Changes = m3/hr
Convert to Litre/Sec
m3/hr ÷ 3600 x 1000 = Litre/Sec
For Example:
Room 24m x 12m x 4.5 m = 1296m3
1296m3/hr x 25 air changes = 32,400m3/hr
32,400 ÷ 3600 x 1000 = 9000 litres/sec
The table below (based on 90% humidity) shows the temperature drop that can be achieved at different levels of humidity. Note that the level of humidity will affect the temperature drop possible, however in the last 5 years many technological advancements have greatly improved the cooling capacity and performance of evaporative coolers.
Air-Changes Selection Table For Various Ambient Air Properties
Temp Ambient Degrees C
Relative Humidity Percentage %
20% 30% 40% 50% 60% 70%
25 13.5 15.5 17.0 19.0 20.5 22.0
30 16.5 19.0 21.0 23.0 25.0 26.5
35 20.2 22.5 25.0 27.5 29.5 31.0
40 23.0 26.0 29.0 31.5 33.5 36.0
45 27.0 30.0 32.5 35.5 38.0 40.5
Based on 90% saturation efficiency
AC20
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING
Down Discharge ModelRealcoldStock No.
Cool BreezeModel No.
kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST
AC8000 D095 7.0 600 75 2000 l/s POA
AC8001 D125 9.0 600 75 2800 l/s POA
AC8002 D160 11.0 750 100 3500 l/s POA
AC8003 D195 13.0 1000 100 4200 l/s POA
AC8004 D230 15.0 1000 100 5000 l/s POA
AC8005 D255 17.0 1000 100 5400 l/s POA
Note: Some models may be available on an indent only basis
Down Discharge Model - Twin FanRealcoldStock No.
Cool BreezeModel No.
kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST
AC8007 FD500 34 2 x 1000 100 mm 10,000 l/s POA
Note: Some models may be available on an indent only basis
Features & Benefits
• Dropper Duct Size 550 mm x 550 mm.
• Dropper Length - minimum allows for 150 mm roof truss & 500mm dropper spigots.
• Up to 24 degree roof pitch 1200 mm
25 degree to 29 degree 1300 mm
30 degree to 34 degree 1500 mm
35 degree plus 1800 mm
• Colour - Beige.
• 12 months warranty on parts only. QM Wall Control
Features & Benefits
• Dropper Duct Size 1165 mm x 585 mm.
• See Quietflo componentry price list for high capacity plenum to suit dropper size.
• Inside view including twin fan layout shown.
• Colour - Beige.
• 12 months warranty on parts only.
CPR Wall Control
AC21
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING
Top Discharge ModelRealcoldStock No.
Cool BreezeModel No.
kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST
AC8008 FT195 13.0 1000 100 4200 l/s POA
AC8009 FT230 15.0 1000 100 5000 l/s POA
AC8010 FT255 17.0 1000 100 5400 l/s POA
Note: Some models may be available on an indent only basis
Side Discharge ModelRealcoldStock No.
Cool BreezeModel No.
kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST
AC8011 S100 8 600 75 2200 l/s POA
AC8012 S240 15 1000 100 5100 l/s POA
Note: Some models may be available on an indent only basis
Features & Benefits
• Unit is supplied standard with ground mounting kit. Optional wall mounting bracket set is available (Refer to accessories section).
• Flexible outlet connector is supplied. It will attach to a duct adaptor from 500 mm to 700 mm square.
• Colour - Beige.
Features & Benefits
• Colour - Beige.
• No Optional bleed-off with side discharge systems.
• 12 month warranty on parts only.
S100. The S100 may be discharged through an optional wall register or duct adaptor. (Refer to accessories section) Alternatively discharge through any appropriate duct adaptor with an internal spigot measurement of 532mm and a minimum spigot length of 30mm.
A stud wall adaptor for use with the optional wall register should be fitted when the mounting wall thickness is less than 230mm. (Refer to accessories section).
S240. Supplied standard with floor mounting bracket. To attach to a wall, purchase an S240 side discharge wall mounting bracket set. (Refer to accessories section).
Flexible outlet connector supplied. It will attach to a duct adaptor from 550mm to 700mm square.
If the S240 is discharging directly through a side wall register into a working or living environment, in order to reduce fan noise, it may be necessary to operate the system at a lower fan speed and therefore the overall cooling capacity will be reduced.
AC22
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING
Mobile ModelRealcoldStock No.
Cool BreezeModel No.
kW Motor Watts Celdek mm Nominal Air Flow System Price$ Excl. GST
AC8013 M240 17 1000 100 5400 l/s POA
Note: Some models may be available on an indent only basis
Features & Benefits
• Tank water capacity 100 litres.
• Colour - Dark Blue.
• Water Inlet - 19 mm male connection for constant water feed via hose pipe.
• Access for manual water fill.
• Large wheels with brakes for full mobile operation.
• It is essential that the Mobile unit is situated near an open door or window to facilitate a constant supply of fresh outside air. Adequate reliefair of at least 4 square metres is required, preferably allowing the cooled air to traverse the area to be cooled before venting to the outside.
• It is essential that the tank be drained at the end of each full day of operation to ensure a minimum concentration of minerals in the tankwater. Failure to do this will reduce the life of the Celdek pads and lower cooling efficiency.
• Includes steel frame which provides more rigidity and allows for transport.
• Note Six Speed Controller is also included - simply rotate the dial to choose your desired fan speed. Fan Only Operation is also available; simply switch off the COOL MODE to circulate fresh outside air.
• 12 months warranty on parts only.
AC23
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE AIR CONDITIONING - ACCESSORIES
Quietflo Plenums - AGP Series With 4 Way PyramidRealcoldStock No.
Cool BreezeModel No.
Description System Price$ Excl. GST
AC8220 QFPA2 AGP2 (D095 - D160) POA
AC8221 QFPA3 AGP3 (D195 - D255) POA
AC8224 QFPA4 AGP4 (FD500 Model) POA
Note: All Quiet Flo Accessories are available on an indent only basis
Plenums AdaptorsRealcoldStock No.
Cool BreezeModel No.
Description System Price$ Excl. GST
AC8222 QFPA2 AGP2 (D095 - D160) POA
AC8223 QFPA3 AGP3 (D195 - D255) POA
AC8225 QFPA4 AGP4 (FD500 Model) POA
Note: To suit above Plenums and 550² Dropper. Moulded from ABS Plastic
Adaptor 2
AGP2
AGP3
AGP4
Adaptor 4
Adaptor 3
Accessories
AC24
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE COOLING
“Wind & Water - Natures own cooling process”
As the term implies - evaporative cooling works by evaporat-ing water into the air stream. This principle is best illustrated in a personal way by that chilling effect you feel when you come out of a swimming pool and a breeze blows across your body. The chilling effect is caused by the evaporation process of the water drying quickly from your body. The same thing happens when you sweat. A “cool breeze” is just air flowing over your body evaporating the sweat. It is nature’s way of keeping us cool during hot weather or physical exertion.
Temperature is measured in two important ways that relate to evaporative cooling. These are “dry bulb” and “wet bulb” tem-peratures expressed in degrees Celsius. There are several other measurements that reflect the amount of moisture in the air. These are “wet bulb depression”, “saturation efficiency”, “dew point”, “kilograms of moisture per kilogram of dry air”, “absolute humidity”, and “relative humidity”. The following brief explana-tion of these measurements will help in the understanding of the process:
Dry Bulb: The ambient (surrounding air) temperature taken with a standard thermometre.
Wet Bulb: The lowest temperature of the air that can be reached by the evaporative cooling process.
Wet Bulb Depression: The difference between the Dry Bulb and Wet Bulb temperatures. I.e. If Dry Bulb is 38C and the Wet Bulb is 21C, the Wet Bulb Depression is 17C. The Wet Bulb Depres-sion is used to determine the efficiency percentage of the cooling media.
Cooling Efficiency or Saturation Efficiency: The percentage tem-perature drop across the media compared to the Wet Bulb De-pression. I.e. If the Wet Bulb Depression is 17 C as above, and the actual temperature drop measured across the media is 14C, the cooling efficiency of the media is 14/17 x 100 = 82.35%. The cool-ing efficiency is commonly referred to as “Saturation Efficiency” as it refers to the amount of moisture that can be evaporated into the air. 100% saturation efficiency would indicate a temperature drop of 17C in the above example of Wet Bulb Depression.
Dewpoint: The temperature at which moisture begins to form on a slick surface indicating 100% saturation of the air with mois-ture. That is how dew develops on grass in the morning. The Dry Bulb air temperature drops to the Wet Bulb temperature level.
Kilograms of moisture per Kilogram of dry air: a method of measuring actual water vapour (moisture) in a kilogram of dry air, most often referred to as the “humidity ratio”.
Absolute Humidity: Actual measurement of water vapour in the air.
Relative Humidity: The percentage of moisture in the air com-pared to the amount of moisture the air could contain. This is the most common reading to be reported in the weather reports.
Evaporation Rate: The rate at which water is absorbed into the air passing through the cooling media. For practical purposes, this rate is measured in litres per hour.
Evaporative Cooling Principles: Evaporative air conditioning functions efficiently in climatic conditions where the natural tem-perature of evaporation (wet bulb) is sufficiently low that the air cooled near this temperature by the process of evaporation can be used directly for air conditioning. The evaporation process involves an adiabatic exchange of heat effecting cooling, by ex-change of sensible heat for latent heat of vaporization of water. The temperature of air is reduced proportionally to the amount of evaporation that takes place, with a maximum theoretical dry bulb reduction equivalent to the difference between the prevail-ing wet and dry bulb temperatures.
The system operates by means of a water pump which supplies a continuous flow of water from a water reservoir to the evap-oration pads - CELDek. The in-flow of water to the reservoir is regulated by a float valve or solenoid valve controlled by a level sensor. 100% fresh air is drawn through the moist pads by the supply air fan. As air passes through the CELDek pads, evapo-ration takes place, cooling the air while maintaining a healthy humidity level.
The cool air is distributed via ducting through grilles and diffus-ers, replacing warm stale air, which is forced out through the open windows, doors or diffusers.
CELDek Cooling Medium
The evaporative pads in most modern evaporative air condi-tioners is a unique, long-life, self supporting pad made from a cellulose material, impregnated with anti-rot salts, rigidifying saturates and wetting agents. The CELDek design incorporates an exclusive cross-fluted configuration which induces a highly turbulent mixing between the cooling water and the air drawn through it. This action contributes to the efficiency of the evapora-tive pads. The construction of this media is unique in that it has alternating, transverse flutes at different angles. The larger pitch angle carries water (introduced to the top of the media) to the front of the media where the oncoming air forces it back into the media assisting in the thorough wetting of the media.
CELDek pads have brought a new dimension to the evapora-tive air conditioning industry - providing an effective and efficient method of humidity control and air cooling. Typical saturation ef-ficiency in a well designed evaporative air conditioner is around 80%.
EVAPORATIVE COOLINGEvaporative Cooling
AC25
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE COOLING
Benefits of CELDek cooling Medium
• A CELDek system does not sag, rot or developholes - allowing hot air to bypass the medium, or allow large quantities of water to drip.
• Duetotheuniquedesignandsaturationefficien-cy, it requires 40% less pad area than old conven-tional Aspen “wood-wool” type pads.
• With proper water management, the CELDekpads will last for years, therefore eliminating an-nual labour and material replacement costs.
• Filtration&Gasscrubber. Inaddition toCELDekshigh efficiency, low maintenance, and low re-sistance to air-flow - it also acts as a particulate filter for particles of 10 microns or greater and “rough cut” gas scrubber. The filtering character-istics should not alarm maintenance personnel, as the CELDek pads are self cleaning. A series of tests conducted by ‘Air Filter Testing Laborato-ries in Louisville, Kentucky, USA performed in ac-cordance to the dust spot efficiency test, ASHRAE Standard 52-76 , and the largest percentage of particles found in the upstream particle test were less than 0.5 microns in size.
• Further details on particulate removal capabilityof CELdek evaporative cooling media available on request.
• Low resistance to air-flow. At typical air veloci-ties of 1.5m/sec, the pressure drop through the CELdek pad is around 20Pa.
• Furtherdetailsonsaturationefficiencyandpres-sure drop through the CELdek available on re-quest.
The typical life of this media is between two and six years, pro-vided the water management system is operational.
Water Management - Water quality
Water always contains a certain amount of dissolved minerals. When evaporation takes place, the mineral concentration in the re-circulated water will increase. To avoid build-up of insoluble minerals - the re-circulating water is discharged by activating an electromechanical dump valve - flushing these accumulated minerals, dust and pollens with the water out of the sump - re-placing this water with fresh water. Alternative to a water dump system is a water bleed off system, where water is discharged whilst the pump is operational. The relation between the “bleed off” water rate and evaporated water volume depends on the quality of the water. To calculate the necessary bleed-off rate, a water analysis of the water feed must be done. Water losses by evaporation and “bleed-off” must be replaced by continuous adding fresh water to the evaporative cooled sump.
Systems which do not incorporate a water management sys-tem are subject to scaling on the pad surface, which causes a decrease in evaporation efficiency, increased resistance to air flow, reduced air volume, reduced life span, and excessive scale build-up in the water distribution system.
World Health Organisation recommended water conditions.
Insoluble minerals which cause scaling include calcium, bicar-bonates & sulphates.
Benefits of Evaporative Cooling
Evaporative air conditioning offers an affordable and practical means of cooling, its operation being at optimum efficiency in areas of high dry-bulb temperatures and low relative humidity. Most refrigerated air conditioning systems rely on recycled cool air, whereas evaporative air conditioning introduces a continu-ous supply of “ideally moistured” fresh, cool air. This naturally cooled, negatively ionised air does not dry nasal passages, skin or eyes, unlike the positively ionised, artificially cooled air from a refrigerated air conditioner. Air borne contaminants like dust and pollen are trapped in the CELDek pads, so the indoor condi-tions are cool, healthy and invigorating.
Economy: There is no compressor, condenser, chiller coils, cool-ing towers or heavily insulated piping used in evaporative cool-ing. The cost of acquisition and operation is a fraction of con-ventional air conditioning and mechanical refrigeration systems. Maintenance costs are minimal requiring simpler procedures and lower skilled maintenance people. An extra benefit is the cost payback due to its’ low energy use and extended useful life of equipment being cooled by it.
Effective: Evaporative cooling has been used for thousands of years in various forms for comfort cooling and is still in com-mon use around the world because of its simplicity, low cost and effectiveness. Unfortunately, many owners of buildings and specifiers of cooling equipment do not seem to realize that it is effective in all areas of the country rather than just in the hotter, drier climates. ASHRAE Handbook, 1995, chapter 47, Evapora-tive Air Cooling notes “...dry bulb temperature reduction due to the evaporation of water always results in a lower effective temperature, regardless of the relative humidity level” and that “...(Evaporative cooling) can provide relief cooling of factories al-most regardless of geographical location.”
Increased Comfort: In a large number of industries it is normal in hot weather to experience increased heat-related illness, lower productivity and increased absenteeism among workers. Many of these industries cannot afford the tremendous costs of conventional mechanical refrigeration or air conditioning, while they can afford evaporative cooling. Quoting again from ASHRAE Handbook, 1995, Chapter 47, Evaporative Air Cooling “evapora-tive cooling can alleviate this heat problem and contribute to worker efficiency with improved morale. If the heat problem is not alleviated, increased absenteeism, high labor turnover and dangers to health and safety during the summer months. Pro-duction declines in uncooled plants may range from 25% to 40% of normal on hot days.”
Health Benefits: Evaporative cooling is 100% fresh air cooling. This means that all the air being cooled is brought in from out-side. It is also necessary to force approximately 90% of all the air coming into the building, out of the building, leaving a nice 10% positive pressure. Today, the term “Sick Building Syndrome” exemplifies the result of continuously re-circulating the air inside the building. The old saying that you can get sick in a hospi-tal is true. The air containing contaminants of all sorts is being breathed in by everyone. In fact, the “no smoking” section of many public buildings is a joke. The same air permeates the en-tire building and is shared by all who breathe it. Fresh air would exhaust these contaminants quickly and harmlessly. National guidelines in building construction now require a percent of all air in the building be fresh air. To further improve the air quality, the rigid cooling media used in today’s evaporative coolers filters to near 1 micron size particles out of the air.
The answer to “Why Evaporative Cooling” is that it is Sensible cooling. It is an important tool in helping to curb the excessive use of energy. It helps clean up the atmosphere since it has no CFC’s or HCFC’s. It is economical, effective; it has health benefits, improves worker and equipment efficiency and provides a much needed alternative to conventional mechanical refrigeration!
Zero ozone depletion as evaporative cooling is a passive cool-ing method that does not use or expel harmful CFC’s.
AC26
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EVAPORATIVE COOLING
Typical Installations
Evaporative coolers can be installed in a multitude of applica-tions. See drawings of typical installations.
Applications
Homes, office buildings, factories, school halls, prisons, livestock confinement, greenhouses, laundries, make-up air for extrac-tion systems, automotive spray paint booths, vegetable storage buildings, gas turbine inlets, gymnasiums, workshops, printers, churches, bakeries entertainment including bars, night clubs, restaurants, cafes, in fact any application where ventilation and/or cooling is required.
Hygiene - Legionella Disease
Evaporative coolers should not be confused with cooling tow-ers or evaporative condensers, which have both been verified as potential Legionnaires’ disease transmitters. In contrast, no cases of Legionnaires’ have been attributed to evaporative cool-ers, for the following reasons.
Evaporative coolers vary substantially in operation and design from cooling towers and evaporative condensers. There are a variety of types including swamp coolers, air washers, humidi-fiers, slingers, atomizers and foggers.
The water used in evaporative coolers is usually from potable water supplies. This water normally contains dissolved miner-als, bacteria (including Legionella) and suspended solids. The air supplied to the cooler may contain a variety of contaminants including dust, dirt, bacteria (including Legionella), soluble gas-es and nutrients. A portion of these impurities are scrubbed by the water. When water evaporates, only pure water is released leaving the impurities behind to accumulate in the water.
The amount of accumulation depends on the water and air quality as well as the operation of the evaporative cooler. If the system is regularly drained, cleaned and allowed to dry out, the accumulations will be substantially reduced. These practices can further prevent the possibility of Legionnaires’ disease origi-nating from evaporative coolers.
Legionella growth is relative to the temperature of the water. It is active at a temperature range of 20C to 45C, with optimum growth occurring at about 37C to 41C. Legionella bacteria are found to be dormant at temperatures less than 20C and are re-tarded at temperatures above 50C. It does not survive in tem-peratures above 60C.
Evaporative coolers most often operate with water temperatures less than 24C, or slightly above the wet bulb temperature, and most often with water temperatures below 20C where Legionel-la bacteria are not active.
As with all microbiological organisms, Legionella bacteria re-quire nutrients and optimum water quality to proliferate. While water temperature is an important factor in bacteria growth, other conditions must exist. These include the presence of nutri-ents, sediments, and other micro-organisms in the water. These so-called dirty systems often provide favourable growth condi-tions of all types of bacteria, including Legionella.
Legionella bacteria enter the lungs via extremely small water droplets (aerosols) of 1 to 5 microns in size. The rod shaped bac-teria can only be transported by microns large enough to hold them. Rigid media type evaporative coolers release water main-ly as a vapour, this vapour is too small to transport the bacteria.
Legionnaires’ disease characteristics
It is important to discuss the causes of this disease and to under-stand how it is contracted. There are three conditions that must be satisfied before Legionnaires’ disease can be contracted:
• ThewatermustcontainviableLegionellabacteriain high levels;
• Finemists of a specific droplet size of the con-taminated water must be inhaled deeply into the lungs; and
• The person inhaling the contaminated finemistmust be susceptible (or have a suppressed im-mune system).
Typical Running Costs
Typical running costs in Auckland for a mid-range cooler with a total of 800w electrical power input, operating for eight hours per day is:
8 hours x 0.8kW x $0.1315/ kWhr = $0.84 in a domestic ap-plication
8 hours x 0.8kW x $0.1489/ kWhr = $0.95 in a commercial application
Calculating the Supply-Air temperature
Example using the wet bulb and dry bulb temperatures in this discussion.
• Tdb=38C
• Twb=21C
• Pad Efficiency 80% (This information is typicallyprovided by evaporative cooler manufacturer.)
Use the formula: T ins = Tdb - (Tdb - Twb) x pad efficiency/100
T ins = 38 - (38 - 21) x 80/100
T ins = 38 - 17 x 0,8
T ins = 38 - 13.6
T ins = 24.4 C
Calculating the Evaporative Air Conditioning Cooling Capacity (Sensible Cooling Capacity)
Example using the following details:
• ms=12000cubicmetresperhour
• TD=13.6C(aspertheaboveexample)
• Density1.2kg/cubicmetre
Use the formula: Qo = ms x TD x sh x air density
= 12000/3600 x 13.6 x 1.2
= 3.334 x 13.6 x 1.2
= 54.41kW sensible cooling.
We can provide assistance in design of evaporative cooling equipment. Starting with the size of the structure you want to cool, we can recommend the correct equipment size and offer different alternatives that could save a lot of time and money. If the need is to replace existing equipment, we can recommend units for that purpose. Sometimes the existing equipment can be made to work effectively by upgrading to a higher efficiency us-ing products like Cool Breeze. Whatever the evaporative cooling need, it would pay to contact us. A wealth of technical informa-tion is available at no cost!
Realcold Ltd.
AC27
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING ACCESSORIES
Mounting Brackets & BasesRealcoldStock No.
Model Description System Price$ Excl. GST
AC0603 AH-YDII Sloped Roof Bracket - For 5.0kW or smaller
Width 250 - 700 mm Depth 230 - 700 mm Slope 11° - 30° Max weight 75 Kg
186.00
AC0609 QKYL-1 Sloped Roof Bracket - For 3.5kW or smaller
Width 250 - 700 mm Depth 230 - 700 mm Slope 10° - 30° Max weight 60 Kg
174.00
AC0611 QKK-1 Wall Type - For 3.5kW or smaller
Width 260 - 760 mm Depth 130 - 360 mm Max weight 60 Kg
145.00
AC0613 AH-KL Wall Type - For 5.0kW or smaller
Width 330 - 630 mm Depth 130 - 360 mm Max weight 75 Kg
191.00
AC0634 QKB1 Flat Surface Type Bracket For 3.5kW or smaller
Width 100 - 600 mm Depth 130 - 330 mm Max weight 60 Kg
165.00
AC1310 CHBRCB-18 Wall Type 1.5 mm Painted Steel
Arms 450 mm Wall Mount 800 mm Max Weight 180 Kg
35.00
AC1311 CHBRCB-25 Wall Type 2.0 mm Painted Steel
Arms 500 mm Wall Mount 1,000 mm Max Weight 250 Kg
48.00
AC1301 CHBRCB-10S Realcold S/S Wall Type - 1.5 mm
Arms 480 mm Wall mount 750 mm Max Weight 75 Kg Stainless Steel 304
89.00
AC1302 CHBRCB-20S Realcold S/S Wall Type - 2.0 mm
Arms 600 mm Wall mount 1,000 mm Max Weight 150 Kg Stainless Steel 304
115.00
AC1303 CHBRRB-10S Realcold S/S Roof Type - 1.5 mm
Can be used as a wall bracket
Arms 480 mm Roof mount 800 mm Max Weight 75 Kg Stainless Steel 304
129.00
AC1304 CHBRRB-20S Realcold S/S Roof Type - 2.0mm
Can be used as a wall bracket
Arms 550 mm Roof mount 1,000 mm Max Weight 150 Kg Stainless Steel 304
185.00
AC1200 MCB450 - 450 mm Medium duty galvanised cantilever bracket 56.15
AC1201 HCB450 - 630 mm Heavy duty galvanised cantilever bracket 79.95
AC1208 Kit 1 c/w 4 x 10 mm coach bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps
20.00
AC1209 Kit 2 c/w 4 x 10 mm dyna bolts, 4 x SNL-M8 channel spring nuts, 4 x M8 bolts, 2 x end caps
20.20
AC1205 M1000 Galvanised steel channel - 3 metre length 68.00
AC1215 SNL-M8 8 mm channel spring nut 1.45
AC1216 SNL-M10 10 m channel spring nut 1.55
AC1220 PS465 Polyslab - Medium 38.65
Refer to page AC35 for Roof Penetration Kit - compliant with NZ Metal Roofing Code of Practise.
AH-YDII
QKYL-1
QKK-1
AH-KL
Stainless Steel Channels
HCB450
MCB450
QKB1
AC28
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING ACCESSORIES
Pre-Insulated Copper TubeRealcoldStock No.
Model Description Wall Thickness Swp System Price$ Excl. GST
Imperial Metric Imperial Metric kPA Psi
TOYO Pair Coil - 20 metre Coil
AC0002 TD-2320-8 1/4" x 3/8" 6.35 x 9.53 0.031 0.031 0.80 0.80 9835 x 6329 1427 x 919 POA
AC0003 TD-2420 1/4" x 1/2" 6.35 x 12.7 0.031 0.031 0.80 0.80 9835 x 4665 1427 x 677 POA
AC0004 TD-2520 1/4" x 5/8" 6.35 x 15.88 0.031 0.039 0.80 1.00 9835 x 4665 1427 x 677 POA
AC0005 TD-3520 3/8" x 5/8" 9.53 x 15.88 0.031 0.039 0.80 1.00 6329 x 4665 919 x 677 POA
AC0006 TD-3630Z 3/8" x 3/4" 9.53 x 19.05 0.031 0.047 0.80 1.20 6329 x 4665 919 x 677 POA
TOYO Single Coil - 20 metre Coil
AC0010 SD-220 1/4" 6.35 0.031 0.80 9835 1427 POA
AC0011 SD-320 3/8" 9.53 0.031 0.80 6329 919 POA
AC0012 SD-420 1/2" 12.7 0.031 0.80 4665 677 POA
AC0013 SD-520 5/8" 15.88 0.039 1.00 4665 677 POA
AC0014 SD-620Z 3/4" 19.05 0.047 1.20 4665 677 POA
REALCOLD Pair Coil - 20 metre Coil
AC0056 OPS-2320 1/4" x 3/8" 6.35 x 9.53 0.031 0.031 0.80 0.80 9835 x 6329 1427 x 919 POA
AC0057 OPS-2420 1/4" x 1/2" 6.35 x 12.7 0.031 0.031 0.80 0.80 9835 x 4665 1427 x 677 POA
AC0058 OPS-2520 1/4" x 5/8" 6.35 x 15.88 0.031 0.039 0.80 1.00 9835 x 4665 1427 x 677 POA
AC0059 OPS-3520 3/8" x 5/8" 9.53 x 15.88 0.031 0.039 0.80 1.00 6329 x 4665 919 x 677 POA
TOYO Aluminium Pair Coil - 20 metre coil c/w specialised flare nuts
AC0100 CAT-2320 1/4” x 3/8” 6.35 x 9.53 0.035 0.039 0.90 1.00 9200 x 6500 1334 x 942 120.00
AC0107 1/4" FNC 1/4" Flare nut and cap set 2.00
AC0108 3/8" FNC 3/8" Flare nut and cap set 2.50
Notes: 1) Values of SWP are derived from the formula from ANSI B31 Standard Code for Pressure Piping. 2) The value of Maximum Stress (S) used in the calculation is 150°F (65.6°C) and is for copper in its annealed condition. For pipe temperatures higher than 150°F (65.6°C), please contact your local Realcold branch for assistance in the selection of appropriate tube for your requirement.
DrainageRealcoldStock No.
Model Description System Price$ Excl. GST
AC0745 DRS Drainage Socket - Drain Y Connector 3.75
AC0749 DRH-14N Drain Hose 14 mm x 50m coil 53.60
AC0755 WRH-16N Drain Hose 16 mm x 50m coil LINED 74.80
AC0817 SDH-20JN Joint for 20 mm Drainage Hose 2.40
Drainage hose is made of Linear Low Density Polyethylene - light weight, high mechanical strength and better UV resistance (5000hr durable in weather testing).
Joint
The Tube Insulation is of double-layered structure made up of cross-linked, foamed, closed cell polyethylene.
The covering is of embossed polyethylene, free of defects, and does not crease when bent. Seamless extrusion is used to ensure close contact with the copper tube, and to enhance the dew-proofing properties. Heat resistance is up to 120º C. and the insulation is manufactured to JIS A9511 P2 Standard.
The Copper Tube is soft annealed and is to JIS H3300 C1220T Standard. R410a compatible.
AC29
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING ACCESSORIES
DuctingThis attractive ivory coloured ducting is easy to install. The slim, square design of the duct and accessories has an aesthetic appearance which will enhance any installation. The duct is made of highly durable, weatherproof PVC resin. Suitable for use in the temperature range -20 to +60ºC
RealcoldStock No.
Model Description Carton Quantities
System Price$ Excl. GST
AC0201 TD-80 80 mm Duct sold in 2 metre lengths 5 20.75
AC0202 TD-120 120 mm Duct sold in 2 metre lengths 4 53.15
Ducting is packed 5 Lengths (AC0201) or 4 Lengths (AC0202) to a Carton
AC0206 DC-80 80 mm Cap 20 8.80
AC0207 DC-120 120 mm Cap 10 21.65
AC0209 DK-80 80 mm Corner 20 8.80
AC0210 DK-120 120 mm Corner 6 21.65
AC0212 DF-80S 80 mm Flexible Joint 20 8.80
AC0213 DF-120 120 mm Flexible Joint 5 20.10
AC0215 DLW-80 80 mm 45º Elbow 20 9.30
AC0217 DL-80 80 mm 90º Elbow 20 10.85
AC0218 DL-120 120 mm 90º Elbow 10 21.65
AC0220 DJ-80 80 mm Joint 50 3.10
AC0221 DJ-120 120 mm Joint 20 9.30
AC0223 DE-80 80 mm End Socket 20 7.25
AC0224 DS-80 80 mm Ceiling Cap 20 11.85
AC0225 DT-120 120 mm T-Joint 5 41.75
AC0226 DB-120 120 mm Branch Joint 5 17.00
AC0227 DR-120 120 mm Reducing Joint 10 17.00
AC0228 WPC-60 Wall Pipe with Flange 60 7.25
AC0229 DS-120 120 mm Duct Ceiling Cap 10 28.85
RealcoldStock No.
Model Description Carton Quantities
System Price$ Excl. GST
AC0501 HB-330 Mounting Base, Ivory 330 mm 50 5.70
AC0503 HB-450 Mounting Base, Ivory 450 mm 30 10.85
AC0510 PQB-36 Quick Base 350 mm 20 11.85
AC0512 PQB-45 Quick Base 450 mm 20 17.55
AC0521 PQC-35 Quick Base Side Cover 8.80
AC0702 PT-1K Sealing Putty, Ivory Colour, Flame proof. 1Kg pack. 11.75
AC0709 VT50 X 20 Self-Adhesive Tape, Ivory 7.25
A mounting base which is designed to maintain the aesthetic qualities of the installation. The sophisticated design, lightweight, rigidity and portability give a considerable advantage over other mounting methods. Made of rigid, waterproof resin, it is suitable for use in the temperature range -20 to +60ºC.
AC0512/AC0521
AC0206/AC0207
AC0501/AC0503
AC0201/AC0202
AC0209/AC0210
AC0212
AC0224
AC0225
AC30
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING ACCESSORIES
Condensate Drain Pipe & FittingsRealcoldStock No.
Description System Price$ Excl. GST
uPVC Pressure Pipe (white) Air Cond & Refrig Drain Pipe
AC1001 15 mm AC&R (3.9 Metre Length) - Packs of 20 7.95
AC1003 20 mm AC&R (3.9 Metre Length) - Packs of 20 12.60
AC1005 25 mm AC&R (3.9 Metre Length) - Packs of 10 19.00
uPVC Pressure Pipe 90 Deg Equal Elbow
AC1010 15 mm Equal Elbow 1.45
AC1012 20 mm Equal Elbow 2.20
AC1014 25 mm Equal Elbow 3.30
uPVC Pressure Pipe 45 Deg Elbow
AC1018 15 mm Injection Mould Bend 2.00
AC1020 20 mm Injection Mould Bend 5.15
AC1022 25 mm Injection Mould Bend 6.00
uPVC Pressure Pipe Equal Tee
AC1028 15 mm Equal Tee 2.00
AC1030 20 mm Equal Tee 2.50
AC1032 25 mm Equal Tee 4.85
uPVC Pressure Pipe Double End Socket
AC1036 15 mm Double End Socket 0.85
AC1038 20 mm Double End Socket 1.25
AC1040 25 mm Double End Socket 2.60
uPVC Pressure Pipe Reducing Socket
AC1044 20 x 15 mm Reducing Socket 2.40
AC1046 25 x 15 mm Reducing Socket 3.20
AC1048 25 x 20 mm Reducing Socket 4.45
uPVC Pressure Pipe Reducing Bush
AC1052 20 x 15 mm Reducing Bush 0.95
AC1054 25 x 15 mm Reducing Bush 2.30
AC1056 25 x 20 mm Reducing Bush 2.60
uPVC Pressure Pipe Male Socket (grey)
AC1060 15 mm Male Socket 2.10
AC1062 20 mm Male Socket 2.10
AC1064 25 mm Male Socket 3.10
uPVC Pressure Pipe P/T Female Socket (grey)
AC1070 15 mm P/T Female Socket 2.10
AC1072 20 mm P/T Female Socket 2.70
AC1074 25 mm P/T Female Socket 3.55
AC31
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING ACCESSORIES
Condensate Drain Pipe & FittingsRealcoldStock No.
Description System Price$ Excl. GST
Solvent (Clear)
AC1078 125 ml Clear Solvent Type P 20.30
AC1080 250 ml Clear Solvent Type P 23.50
White Pipe Saddle (full)
AC1090 Full Pipe Saddle 15 mm 0.95
AC1092 Full Pipe Saddle 20 mm 0.95
AC1094 Full Pipe Saddle 25 mm 1.05
Zinc Plated Pipe Saddle (Single side)
AC1096 Single Sided Clip 15 mm 0.25
AC1098 Single Sided Clip 20 mm 0.25
EZ Trap - The Trap ExpertsRealcoldStock No.
Description System Price$ Excl. GST
20mm Transparent Cross Trap
AC1102 Cross Trap 42.85
Flexible Brush - Clean out your Trap
AC1108 Flexible Brush 11.55
Socket UnionRealcoldStock No.
Description System Price$ Excl. GST
AC1110 15 mm Socket Union / Mac Union / Connection 23.00
AC1112 20 mm Socket Union / Mac Union / Connection 45.25
AC1114 25 mm Socket Union / Mac Union / Connection 37.30
AC1102 20 mm
Transparent Trap
AC1108 Flexible Brush
AC1112 20 mm Socket Union / Mac Union / Connection
AC32
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
CONDENSATE PUMPS
Hi Lift PumpsRealcoldStock No.
Description System Price$ Excl. GST
T0911 Aspen Hi-lift Tank Pump 1.0 Litre Tank
Description: Peristaltic Rotary Type Pump. Designed to collect and pump a smaller volume of water to a greater head. Requires 230V supply only. Fits into a shallow ceiling void or unit.
Features: No siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Pumps water, fibrously contaminated water and air.
Technical: Pump rating 1ph, 0.4A, 230 VAC, 50Hz. Safety switch 4.0A max. Water flow rate 11 l/hr @ 12 metres head. Max head is 12 metres. Inlet 2 x 25 mm, outlet size is 6 mm. Tank capacity 1.0 litre.
Dimensions: 132 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.
298.00
T0912 Aspen Hi Lift Tank Pump 2.0 Litre Tank
Description: Peristaltic Rotary Type Pump. Designed to collect and pump a smaller volume of water to a greater head. Requires 230V supply only. Fits into a shallow ceiling void or unit.
Features: No siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Pumps water, fibrously contaminated water and air.
Technical: Pump rating 1ph, 0.4A, 230 VAC, 50Hz. Safety switch 4.0A max. Water flow rate 11 l/hr @ 12 metres head. Max head is 12 metres. Inlet 2 x 25 mm, outlet size is 6mm. Tank capacity 2.0 litres.
Dimensions: 160 mm high x 235 mm wide x 140 mm deep. Weight 2.0Kg.
315.00
Hi Flow PumpsRealcoldStock No.
Description System Price$ Excl. GST
T0913 Aspen Hi-Flow Condensate Pump 1.0 Litre
Description: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.
Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.
Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 1.0 litre.
Dimensions: 130 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.
157.00
T0914 Aspen Hi-Flow Condensate Pump 2.0 Litre
Description: Centrifugal Type Pump. Designed to collect and pump a high volume of water to a lesser head. Requires 230V supply only. In all cases the hi-flow pump must be sited under the source of the condensate.
Features: In-line valve to prevent siphoning back. Clear deck for quick and easy inpection. Incorporated back plate for vertical mounting. Pre-wired safety switch. 2 x 25 mm inlet positions. Made of fire retardant plastics. Auto re-setting thermal cut-out to shaded pole motor. Conecting cable 2 metres.
Technical: Pump rating 1ph, 0.2A, 230VAC, 50 Hz. Safety switch 4.0A max. Discharge head 4 metres max. Water pumping capacity 288 L/H max. Tank capacity 2.0 litres.
Dimensions: 160 mm high x 235 mm wide x 140 mm deep. Weight 1.8Kg.
157.00
Get AcTabs to prevent drain pan overflow and odours:
AC33
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
CONDENSATE PUMPS - WARRANTY PARTS ONLY
Universal PumpRealcoldStock No.
Description System Price$ Excl. GST
T0916 Aspen Universal Pump
Description: Peristaltic Rotary Type Pump. Self priming to 3m. Pumps water, fibrously contaminated water and air. Requires two sensores to read air on/off on the evaporator coil.
Features: Operates by sensing 5°C differential across the evaporating coil. 3 minute timer overrun on stop. No siphoning back. Operates only on cooling. Manual test switch. 3m connecting cable. Wall mounting bracket included. Made of fire retardant plastics.
Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz. Water flow rate 6.25 l/hr @ 12 metres head. Max head is 12 metres. Inlet / outlet size is 6 mm.
Dimensions: 142 mm high x 160 mm wide x 83 mm deep. Weight 1.5Kg.
313.00
Supermarket PumpRealcoldStock No.
Description System Price$ Excl. GST
T0960 Aspen Supermarket Pump
Description: This pump is designed to be installed underneath refrigeration chiller units to collect water during the defrost cycle.
Features: Operates on a hall effect float / sensor. Thermally protected 230V continuously rated motor. High level safety switch. Tank capacity 11 litres. Push-in plug connector. Fliter to catch debris. Made of fire retardant ABS plastics.
Technical: Pump rating 1ph, 0.35A, 230 VAC, 50Hz. Water flow rate 225 l/hr @ zero metres head. Max head is 30 metres. Inlet size 50 mm / outlet size is 10 mm. Water temp 0°C to 40°C.
Dimensions: 100 mm high x 590 mm wide x 405 mm deep. Weight 4.9Kg.
740.00
AC-Tabs
Actabs with its EPA registered biocide eliminates or prevents most blockages in air conditioning and refrigeration drain lines due to the buildup of bacterial slime, rust, scale, sludge, air bourne dust, silty and other solids.
• Unique automatic metering dispenser
• EPA Registered
• Prevents Costly Water Overflow Damage
• Eliminates Bacteria Casused Bad Odours
• Can be used in Computer Rooms
AC34
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
CONDENSATE PUMPS - WARRANTY PARTS ONLY
Compact Pumps - Hidden InstallationRealcoldStock No.
Description System Price$ Excl. GST
T0939 Aspen Mini Aqua*
Features: Our smallest pump ever fits all wall mount splits. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Mounts vertically or horizontally, Versatile and quiet operation.
Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. 21 dBA @ 1 metre.
Dimensions: 28 mm high x 165 mm wide x 28 mm deep. Weight 0.18Kg.
228.00
T0940 Aspen Mini Orange*
Features: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat.
Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. Suction lift 1 metre. 23 dBA @ 1 metre.
Dimensions: 51 mm high x 107 mm wide x 39 mm deep. Weight 0.25Kg.
228.00
T0941 Aspen Maxi Orange*
Features: Designed to be installed above ceilings, behind wall mounted evaporators and in plastic conduit. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Both pump and reservoir must be mounted flat.
Technical: Pump rating 1ph, 0.25A, 230VAC, 50Hz, 21 watts. Water flow rate 37 l/hr @ zero head. Max head 20 metres. Suction lift 1 metre. 35 dBA @ 1 metre.
Dimensions: 66 mm high x 122 mm wide x 44 mm deep. Weight 0.45Kg.
263.00
T0942 Aspen Mini Lime*
Features: Designed to be installed in the plastic conduit supplied. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Reversible. Box contains the pump, elbow, 800m conduit, connection sleeve and ceiling plate.
Technical: Pump rating 1ph, 0.2A, 230VAC, 50Hz, 16 watts. Water flow rate 14 l/hr @ zero head. Max head 8 metres. 23 dBA @ 1 metre.
Dimensions: 79 mm high x 99 mm wide x 44 mm deep. Weight 0.31Kg.
289.00
Note: Pacific pumps use an electronic sensor. Mini Aqua, Mini Orange, Maxi Orange & Mini Lime pumps have an electro-mechanical sensor.*Warranty is null or void unless all pumps purchased are installed with inline filter T0926.
*Compact Pump In-Line FilterRealcoldStock No.
Description System Price$ Excl. GST
T0926 Condensate Filter PF2
Features: Removes sludge and dirt particles as well as hairs. Large surface area gives minimum intruption to water flow.
Technical: Failure to install a condensate filter can void the Compact Condensate Pumps warranty.
25.45
Anti Siphoning Device - BRAND NEW - Revolution From Aspen
• Theleadingsolutiontopreventsiphoning • Evenfasterandeasierinstallations
• Hasslefreecondensatepumpfitting • Uniqueandrevolutionarydesign
• Completepeaceofmind • Exclusively free with Aspen Mini Pumps
COMIN
G SOON
April 2012
AC35
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
Heat Pump AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
N0495 Top Hat Roof Penetration Kit contains:
• Dktite flexible flashing• PVC slotted pipe• PVC cover flashing• PVC cap• 12 hex head screws• Bostik sealant• Complies with NZ Metal Roofing Code of Practise
87.55
AC1701 Universal Remote Control for A/C Ultra Plus Hi-wall 95.00
CONDENSATE PUMPS - WARRANTY PARTS ONLY
Spares For PumpsRealcoldStock No.
Description System Price$ Excl. GST
T0905 Peristaltic Tubes 29.60
T0920 6 mm Clear Plastic Tubing for condensate pumps 1.80
T0922 Aspen non-return valve 6 mm 8.25
T0924 Aspen straight connector 5.60
T0926 Filter kit for all compact condensate pumps 25.45
T0927 Aspen Plastic Fitting 3.65
T0928 Aspen Universal Sensor 93.75
Compact Pumps - Below Wall Unit InstallationRealcoldStock No.
Description System Price$ Excl. GST
T0938 Aspen Mini Blanc Pump Deluxe
Features: Designed to sit below the indoor unit. Offers easy access for fast efficient servicing. 3A volt free alarm wires, NO NC contacts rated at 5A inductive at 230V. Hall effect semi conductor level sensors, with high level safety. Thermally protected. Cleanable / replacable 70 micron internal filter.
Technical: Pump rating 1ph, 0.2A, 230 VAC, 50Hz, 16 watts. Alarm relay rated at 5A / 250VAC. Max water flow rate, 12 l/hr @ zero head. Max head 10 metres, 21 dBA @ 1m.
Dimensions: 115 mm high x 182 mm wide x 53 mm deep. Weight 0.46Kg.
222.00
Note: Pacific pumps use an electronic sensor. Mini Aqua, Mini Orange, Maxi Orange & Mini Lime pumps have an electro-mechanical sensor.*Warranty is null or void unless all pumps purchased are installed with inline filter T0926.
Heat Pump Accessories
AC36
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
ELECTRICAL & THERMOSTATS
Components & FittingsRange of electrical components to assist air conditioning installers.
RealcoldStock No.
Description Base Unit of Measure System Price$ Excl. GST
E1098 Weatherproof Switch 15A Unit 33.95
E1099 Weatherproof Switch 35A Unit 44.95
E2012 2.5 mm, 3 Core TPS, 2C + Earth Metre 1.99
E2026 1.5 mm, 4 Core TPS, 3C + Earth Metre 3.15
E2024 2.5 mm, 4 Core TPS, 3C + Earth Metre 4.40
E2020 Connector Terminal Single 40A Jar 32.00
E2023 Flex 25 mm Conduit Metre 2.95
Seitron Air Conditioning ThermostatsRealcoldStock No.
Model No Description System Price$ Excl. GST
Electronic Thermostats (Heatpumps)
G4520 TAEZN4MC Electronic Heatpump t/stst 230V AC - Use STLNTSA150 Sensor 174.00
G4521 TAEZN42C Electronic Heatpump t/stst 24V AC - Use STLNTSA150 Sensor 174.00
G4522 TAEZN2MC Electronic Heatpump t/stst 230V AC On / Off Switch - Use STLNTSA150 Sensor 182.00
G4523 TFEZN4MC Electronic Heatpump t/stst 230V AC On / Off & 3 Speed Fan Switches - Use STLNTSA150 Sensor
198.00
G4524 TFPF03MC Diamond Eelctronic programable Heat pump t/stat with Digital display, 230V AC - Use STLNTSA150 Sensor
190.00
Mechanical Heating / Cooling Thermostats
G4525 TAM011MI TAM, 16A Heating / 5A Cooling 8…30°C 230V AC 36.00
G4526 TAM013MI TAM, 5A 8…30°C 230V AC On / Off Switch 45.00
Electronic Heating Thermostat
G4527 Magictime Programable heating t/stat, 7 day/24hr digital analogue display - use STLOTSA150 NTC Sensor
202.00
Sensors and Accessories
G4553 STANP3 NTC Room Sensor for TAEZN / TFEZN series t/stats 49.00
G4554 Sensor Housing Plastic Sensor Housing 24.00
G4555 STLNTSA150 Remote NTC Sensor - Probe with 1.5m lead 4700ohm @ 25°C 39.00
G4556 STLOTPA150 Magictime Remote NTC Sensor 100kohm @ 25°C 39.00
AC37
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
Saginomiya 4-Way Reversing ValveRealcoldStock No.
Model Description Capacity Refrigerator Pipe Sizes Coil Voltage System Price$ Excl. GSTR22 R410a Discharge Suction & Coils
G1100 CHV-0201
STF-0201"G"
Reversing Valve C/W Coil
2.6 3 R22 R407c R410a
9.52 (3/8") 12.7 (1/2") YES 230V AC 50Hz
87.55
G1112 STF-0214"G" Reversing Valve C/W Coil
3 R22 R407c R410a
12.7 (1/2") 15.88 (5/8") YES 230V AC 50Hz
87.55
G1114 STF-0408"G" Reversing Valve C/W Coil
6 R22 R407c R410a
12.7 (1/2") 19.05 (3/4") YES 230V AC 50Hz
364.00
G1103 CHV-1511 Reversing Valve without Coil
10.9 n/a R22 R407c
22 (7/8") 28.5 (1.1/8") NO - POA
G1104 CHV-3001 Reversing Valve without Coil
25 n/a R22 R407c
32 (1.1/4") 38.4 (1.1/2") NO - POA
ACSG0301 SHF-7H-34U Reversing Valve without Coil
2 2.3 R22 R407c R410a
9.52 (3/8") 12.7 (1/2") NO - 105.00
ACSG0169 SHF-20A-46 Reversing Valve without Coil
5.7 6.7 R22 R407c R410a
12.7 (1/2") 19.05 (3/4") NO - 105.00
CHV Coils for Reversing Valves
G1105 CHV-01AI501A1
CHV Coil suits CHV/STF 101~2011
- - - - - - 230V AC 50Hz
31.45
G1106 CHV-MOAI1032B1
CHV Coil suits CHV/STF 2501~3001
- - - - - - 230V AC 50Hz
31.45
4 WAY VALVES
AC38
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DUCTING ACCESSORIES
Flexible DuctingRealcoldStock No.
Diameter (mm) Length (m) System Price$ Excl. GST
Comflex Nude
ACDCT0367100
3 8.35
ACDCT0409 6 16.70
ACDCT0368125
3 10.85
ACDCT0410 6 16.70
ACDCT0369150
3 13.95
ACDCT0411 6 17.25
ACDCT0377200
3 12.30
ACDCT0412 6 22.80
ACDCT0370250
3 12.80
ACDCT0413 6 25.55
ACDCT0380300
3 16.70
ACDCT0414 6 31.75
ACDCT0415350
3 20.60
ACDCT0416 6 40.10
ACDCT0417400
3 25.55
ACDCT0418 6 48.45
Comflex Insulated
ACDCT0088150
3 24.85
ACDCT0399 6 42.25
ACDCT0089200
3 31.45
ACDCT0343 6 55.15
ACDCT0400250
3 35.65
ACDCT0344 6 63.45
ACDCT0401300
3 41.75
ACDCT0402 6 74.60
ACDCT0403350
3 48.45
ACDCT0404 6 87.35
ACDCT0405400
3 55.65
ACDCT0406 6 99.65
Note: 450 - 600 mm Diameters are available by special order
Comflex Ducting
• Fully complies to AS4254 & AS4508 & AS1530 Pt3 and NZ Bldg Code
• DUCT CORE: Aluminium foil laminated onto polyester film, permanently bonded onto a corrosion resistant coated, spring steel wire helix
• DUCT SLEEVE: Fire retardant 75 um black low density polyethylene and UV stabilised
• DUCT INSULATION: AS4508 Polyester R0.6 nominal 250 grams per mtr/sq 40 mm thick
• TEMPERATURE RANGE: Maximum: +80˚C Minimum: -10˚C
• COLOUR: Silver with black sleeve
Note: No glued/adhesive duct should be installed in a compressed or ovalised state for fear of long term failure
COMFLEX™ Nude
COMFLEX™ Insulated R0.6 (40 mm)
AC39
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DUCT FITTINGS
Branch Take-Off - PolyRealcoldStock No.
Metric Size System Price$ Excl. GST
ACDCT1439 100-100-100 35.75
“Y” Piece - PolyRealcoldStock No.
Metric Size System Price$ Excl. GST
Poly Nude - Non Insulated
ACDCT1233 150-150-150 20.60
ACDCT0379 200-150-150 20.60
ACDCT0471 250-200-200 22.25
ACDCT0717 300-250-250 28.55
ACDCT0718 350-300-300 44.60
ACDCT0813 400-350-300 60.05
Reducers - PolyRealcoldStock No.
Metric Size System Price$ Excl. GST
Poly Nude - Non Insulated
ACDCT2067 125-100 7.55
ACDCT2066 150-125 8.55
ACDCT0486 200-150 12.10
ACDCT0487 250-200 14.35
ACDCT0488 300-250 16.00
ACDCT0489 350-300 18.35
ACDCT0490 400-350 19.50
AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
ACDCT0808 Hanging Strap 25 mm x 50 m 7.45
N0185 Insulation Tape 48 mm x 30 m roll - self adhering PVC (light grade) 9.70
N0187 Insulation Tape 48 mm x 30 m roll - self adhering PVC (heavy grade) 17.00
N0402 Aluminium Duct Tape 51 mm x 45.72 m roll 18.05
N0404 Silver Duct Tape 51 mm x 54.86 m roll 18.05
• Manufactured from HDPE
• U.V. stabilised• Heavy duty,
robust• Smooth internal
lines• No sharp edges• Positive lock
duct tabs
• Poly - High Density Polyethylene (HDPE)
Duct Joiners - Galv & PolyRealcoldStock No.
Description System Price$ Excl. GST
ACDCT0059 150 mm Galv Duct Joiner 13.95
ACDCT0071 200 mm Galv Duct Joiner 15.45
ACDCT0339 250 mm Galv Duct Joiner 19.10
ACDCT0723 150 mm Poly Duct Joiner 6.05
ACDCT0724 200 mm Poly Duct Joiner 7.45
ACDCT0725 250 mm Poly Duct Joiner 8.45
ACDCT0726 300 mm Poly Duct Joiner 9.75
ACDCT0770 350 mm Poly Duct Joiner 13.40
ACDCT0771 400 mm Poly Duct Joiner 19.22
ACDCT0772 450 mm Poly Duct Joiner 22.90
Duct Fittings
AC40
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DIFFUSERS
CD2000 One Piece 4-Way DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT0792 225 x 225 POA
ACDCT0468 300 x 300 POA
ACDCT0793 375 x 375 POA
• Manufactured from v-zero fire rated ABS plastic. AS/NZ 1530.3
• Resistant to scratching and fading
• Minimises problems associated with cold bridging in high humidity areas
• Spring loaded fixing clips
• Poly neck adaptors and side entry cushion boxes - refer page AC42
Univent (Fixed Blade) Diffuser - Face OnlyRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT1022 225 x 225 33.50
ACDCT1019 300 x 300 36.90
ACDCT1023 375 x 375 37.20
• Manufactured from high impact polystyrene, resistant to scratching and fading
• Minimises problems associated with cold bridging in high humidity areas
• Quick fixing clips, no tools required
• Adjustable airflow patterns
• Poly neck adaptors and side entry cushion boxes - refer page AC42
Double Deflection Grille - Wall DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT2020 300 x 100 46.35
ACDCT2021 350 x 150 51.40
• Manufactured in high quality aluminium extrusion profiles, powder coated white
• Designed with nylon brushes for efficient, smooth operation
• Deflection blades are adjustable individually
• Standard 20mm blade spacing
• Suits poly boots DCT0714, DCT0715 - refer page AC42
MAXVENT® One Piece 4-Way DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT2007 225 x 225 41.20
ACDCT2008 300 x 300 62.35
ACDCT2009 375 x 375 84.60
• One piece pressed aluminium, powder coated white
• Removable core, no joints, smooth airflow
• Poly neck adaptors and side entry cushion boxes - refer page AC42
• Technical data available
Diffuser
AC41
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
DIFFUSERS
One Piece Plaque DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT2012 225 x 225 POA
ACDCT1516 300 x 300 POA
ACDCT2014 375 x 375 POA
• One piece pressed aluminium, powder coated white
• Removable core, no joints, smooth airflow
• Poly neck adaptors and side entry cushion boxes
• Technical data available
• 595 x 595mm “lay in” T-rail diffuser
MAXVENT® Cone Ceiling DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT1472 150 16.80
ACDCT1473 200 26.50
ACDCT1474 250 44.30
ACDCT1475 300 55.25
• Manufactured from ABS plastic• Spring loaded fixing clips• Resistant to scratching and fading• Positive lock duct tabs• Adjustable screw in centre cone
UNIJET “Jet Centre” Ceiling DiffuserRealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT0500 150 29.80
ACDCT0501 200 43.50
ACDCT0098 250 49.75
• Manufactured from V Zero fire rated ABS plastic AS/NZ 1530 pt 3• Spring loaded fixing clips• Adjustable ‘set and forget’ damper blade• Comes with damper blade adjustment tool• Resistant to scratching and fading• Positive lock duct tabs
Opposed Blade Damper (OBD)RealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT2016 225 x 225 POA
ACDCT2017 300 x 300 POA
ACDCT2018 375 x 375 POA
ACDCT2019 450 x 450 POA
• Manufactured in high quality aluminium extrusion profiles
• Designed with nylon bearings for efficient, smooth operation
• Clips onto one piece 4-Way aluminium diffusers
• Powder coated black
• Opposed blade damper design to ensure regulation of airflow
• Screw type opening mechanism
AC42
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
NECK ADAPTER
Neck Adapter - PolyRealcoldStock No.
Metric Size System Price$ Excl. GST
RealcoldStock No.
System Price$ Excl. GST
No Damper With Damper
ACDCT0681 225 x 225-150 12.10 - -
ACDCT0545 225 x 225-200 12.10 - -
ACDCT0497 300 x 300-250 14.35 ACDCT0498 20.85
ACDCT0509 300 x 300-300 14.35 ACDCT0499 20.85
ACDCT0547 375 x 375-250 16.00 - -
ACDCT0549 375 x 375-300 16.00 - -
ACDCT0553 375 x 375-350 16.00 - -
ACDCT0555 375 x 375-400 16.00 - -
• To convert 250 mm to 200 mm spigots use DCT0965
Stepped SpigotRealcoldStock No.
Metric Size System Price$ Excl. GST
No Damper
ACDCT1409 550 x 550/400/450 28.55
Convert 250mm SpigotsRealcoldStock No.
Metric Size System Price$ Excl. GST
ACDCT1142 250-150 11.05
ACDCT0965 250-200 11.05
• Poly Adaptor “Snaps-On” to plastic diffusers, no tools or fixing required• Manufactured from high impact polystyrene, positive lock duct tabs• Poly neck adaptors to suit Uni-Vents, CD 2000 and some aluminium diffusers
Cushion Side Entry Box - PolyRealcoldStock No.
Metric Size System Price$ Excl. GST
Poly Insulated
ACDCT1003 225 x 225-200 37.20
ACDCT1006 300 x 300 -200 45.75
ACDCT0972 300 x 300 - 250 45.75
• Manufactured from HDPE, fits poly and aluminium diffusers
Boots - FloorRealcoldStock No.
Metric Size System Price$ Excl. GST
Poly Insulated
ACDCT0714 300 x 100-150 17.35
ACDCT0715 350 x 150-200 29.70
• Manufactured from high density polyethylene• U.V. stabilized• Robust, heavy duty• Smooth internal lines • Complete with collar and damper• Positive lock duct tabs, nail holes pre punched
left: no Damper right: with Damper
Neck Adapter
AC43
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
EGGCRATE GRILLE
Eggcrate Grille - Fixed Core (ERG)RealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT1989 150 x 150 20.60
ACDCT2002 225 x 225 28.55
ACDCT2003 300 x 300 39.45
ACDCT2004 375 x 375 50.90
*ACDCT2005 550 x 550 98.90
*595 x 595 mm “lay in” T-rail grille
• Manufactured in high quality aluminium extrusion profiles
• Flush face finish
• Powder coated white
• Poly neck adaptors see page AC42
Eggcrate Grille - With Filter (ERHFG)RealcoldStock No.
Neck Adaptor Size System Price$ Excl. GST
ACDCT0962 300 x 300 129.00
ACDCT1257 375 x 375 133.00
*ACDCT0966 550 x 550 169.00
*595 x 595 mm “lay in” T-rail grille
• Manufactured in high quality aluminium extrusion profiles
• Hinged removable filters
• Flush face finish
• Powder coated white
• Filter media G2 rated
• Poly neck adaptors see page AC42
Eggcrate Grille
AC44
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
WALL / CEILING FANS / GRILLS
MAXVENT® - 150 mm Wall / Ceiling FanRealcoldStock No.
Description System Price$ Excl. GST
ACFAN0007 150mm Wall / Ceiling Fan 64 l/s Standard 96.10
MANROSE® Wall / Ceiling Grille with Duct SpigotRealcoldStock No.
Metric Size Colour System Price$ Excl. GST
Fixed Louvre
ACDCT0025 100 White 10.00
ACDCT0041 120 White 14.45
ACDCT0063 150 White 22.80
ACDCT0340 200 White 56.55
MANROSE® Weatherproof CowlRealcoldStock No.
Metric Size Colour System Price$ Excl. GST
ACDCT0018 100 White 14.45
ACDCT1031 150 White 42.65
• Used where adverse weather conditions are experienced
AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
ACFAN0372 Delay Timer 28.85
• Suits fans 20-200W
• Suitable for retrofit
• Switches off after 7mins
• Standard grille with some weather protection
• Removable insert for ease of installation & cleaning
Wall / Ceiling Fans / Grills
AC45
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
ROOF VENTILATION
Roof Fan Kits with Dektite & HDPE TubeRealcoldStock No.
Metric Size Fan Type Litres Per Second Air System Price$ Excl. GST
ACFAN0530 150 Ctr’fgl 130 l/s Extract 394.00
ACFAN0532 150 Axial 80 l/s Extract 280.00
ACFAN0534 150 Axial 80 l/s Supply 280.00
• Fan incorporated within the cowl
• Aluminium cowl construction
• Pleasing aesthetics
• High quality for longevity of operation
• Electrical connection can be made inside or outside roof space
• Dektite included (for metal based roofs), all fittings supplied
• Optional lead dektite available to order
NB: Lead Dektite (DCT0190) required for
concrete tile roofs
NB: Lead Dektite (DCT0190) required for
concrete tile roofs
Roof Fan & Cowls
Roof Cowl Kits with Dektite & HDPE TubeRealcoldStock No.
Metric Size Description System Price$ Excl. GST
ACDCT0172 150 General Purpose Kit 122.00
• General purpose cowl included
• 0.5m HDPE Tube included
• Dektite included (for metal based roofs)
• All fittings supplied
• Optional lead Dektite available to order
• Refer to page AC35 for Roof Penetration Kit - compliant with NZ Metal Roofing Code of Practise
Roof Ventilation
AC46
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
IN LINE FANS
High Performance Centrifugal In-Line FansRealcoldStock No.
Metric Size Performance dBA 3m* Max. Pressure (Pa) System Price$ Excl. GST
ACFAN0358 250 280 l/s, 1008 m3/hr 46 500 418.00
* dBA @ 3 metres - sound pressure based on the high speed for each fan
• Manufactured from V Zero fire rated ABS plastic
• Centrifugal fan design, quality external rotor ball bearing motor
• Motor wired to junction box
• Fan mounting brackets available
• Continuously rated motor
• Pressure curves - refer page AC52
MAXVENT® High Performance Axial In-Line FansRealcoldStock No.
Metric Size Performance dBA 3m* Max. Pressure (Pa) System Price$ Excl. GST
ACFAN0085 150 89 l/s, 320 m3/hr 46 135 126.00
* dBA @ 3 metres - sound pressure based on the high speed for each fan
• Quality ball bearing motor
• Integral mounting
• High performance axial fan
• Continuously rated motor
• Technical data - refer page AC52
MIXFLO™ Mixed Flow In-Line FansRealcoldStock No.
Metric Size Model Max. Airflow (l/s)
Max. Pressure (Pa)
dBA 3m* System Price$ Excl. GST
ACFAN1004 100 MF100 69 200 40 182.00
53 120
ACFAN1005 125 MF125 89 230 43 201.00
72 160
ACFAN1006 150 MF150 156 360 47 225.00
117 320
ACFAN1007 200 MF200 253 300 48 274.00
228 225
200 150
* dBA @ 3 metres - sound pressure based on the high speed for each fan
• Designed for applications that require high air flows with relative low noise
• High quality ball bearing, long life motors, continuously rated and warranted for a minimum of 30,000 hours or 4 years
• Can be easily installed in series to increase pressure
• 2 speed fan settings for 100mm, 125mm and 150mm models and 3 speed fan settings for the 200mm model
• Brackets are supplied with the fan for ease of installation
• Fan assembly can be easily removed from rigid ducting installations for ease of cleaning and maintenance.
• Double Insulation - no earth required
• Technical data - refer pages AC52
In Line Fans
AC47
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
IN LINE FANS - TECHNICAL DATA
Fan Dimensions (mm)Model A B* C D E F G
MF100 98 182 262 100 100 168 21
MF125 122 182 262 100 100 168 60
MF150 147 209 293 130 115 192 60
MF200 197 244 354 142 140 230 52
*Measured with junction box on side (junction box height of 35mm)
Technical SpecificationModel Order Code Size (mm) RPM Wattage Max.
Airflow (l/s)Max. Pressure (Pa)
Lp dBA 3m* kg IP Rating Max. Operating Temp °C
MF100 FAN1004 1002300 40 250 200
40 2.1 X4 451700 18 190 120
MF125 FAN1005 1252300 40 320 230
43 2.1 X4 451700 18 260 160
MF150 FAN1006 1502700 70 560 360
47 3.2 X4 452000 60 420 320
MF200 FAN1007 200
2700 85 910 300
48 4.5 X4 452350 60 820 225
2000 45 720 150
* dBA @ 3 metres - sound pressure based on the high speed for each fan
Sound Power Levels (high speed)Model Sound Power Levels LW (dBA) - Octave band centre frequency in Hz LwA dBA
125 250 500 1000 2000 4000 8000
MF100 50 56 58 58 52 47 37 61
MF125 52 59 60 60 56 49 41 63.5
MF150 58 66 65 63 62 54 46 67.5
MF200 65 69 64 63 62 60 48 69
AC48
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
IN LINE FANS - FAN CURVES
MIXFLO™ Mixed Flow In-Line Fans - Performance Curve
AC49
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
IN LINE FANS - TECHNICAL DATA
High Performance Centrifugal In-Line Fans ACFAN0358 Technical Data
Axial In-Line Performance Curves
MAXVENT™ High Performance Axial In-Line Fans ACFAN0085 Technical Data
Hyper150 High Performance Axial FanNoise Level dBA @ 3m 46
Frequency Hz 50/60
Power Input W 38
Current A 0.38
Speed RPM 2650
Voltage V 240
Weight kg 1.3
Max. Ambient Temp °C 70
Axial In-Line Fan Dimensions
AC50
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
TRANSFER FANS
MAXVENT™ Heat Transfer SystemRealcoldStock No.
Description System Price$ Excl. GST
ACFAN0475 150 mm Maxvent™ (1 Room) Heat Transfer 290.00
ACFAN0542 150 mm Maxvent™ (2 Room) Heat Transfer Plus 540.00
ACFAN0543 200 mm Maxvent™ (3 Room) Heat Transfer 655.00
The Maxvent™ Heat Transfer system utilizes otherwise wasted heat by distributing excess heat throughout the home. The heat transfer system works by slowly drawing air from the heated room and transferring it to a remote room via the ducting and fan in the ceiling space.
Benefits
• The Heat Transfer system increases home heating efficiency by transferring previously ‘wasted’ heat to other parts of the home.
• High quality, durable components are used, including high performance fans and thermostat controller.
• Maxvent™ Heat Transfer is a complete kit incorporating all of the components needed for a standard job.
Transfer Fans
AC51
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING WARRANTY INFORMATION
The warranty is applicable to Gree products purchased from Realcold Limited and installed in New Zealand. Mitsubishi Heavy Industries warranty is held by Mitsubishi Heavy Indus-tries Air-Conditioners Australia Pty Ltd.
Realcold Limited (herein called the company) warrants the prod-ucts are free of defects from manufacture. Any proven defect will be rectified by the company, or an authorized service agent, free of charge within the appropriate time limits and subject to the conditions set out on the New Zealand warranty card supplied with the air conditioner.
5 YEAR WARRANTY Residential Installation
2 YEAR WARRANTY Commercial Installation (See notes below)
Multi Inverter Air Conditioners (only 24 month warranty applies for process cooling and commercial applications).
Split Type Hi-wall Air Conditioners (only 24 month warranty ap-plies for process cooling and commercial applications).
Window Air Conditioners (only 24 month warranty applies for process cooling and commercial applications).
Heat Recovery Ventilators (only 24 month warranty applies for process cooling and commercial applications).
Notes
1 In home service available in major metropolitan areas or within 30 km from service agents only. Consumers in ar-eas other than the above will require prior authorization from the company for any mileage and travel charges.
2 Multi, Split and / or Ducted Air Conditioners must be in-stalled by a qualified installer.
3 Regular maintenance must be carried out at intervals not exceeding one year and the maintenance record com-pleted on the retained warranty card as each service occurs.
4 The removable portion of the warranty card must be fully completed and returned to the company to register your warranty.
Contractor / Installer responsibilities:
• Install the air conditioner as per the manufacturer’s instructions.
• Installation is to be done by a qualified tradesperson following best trade practices.
• Theequipmentmustbesafelyaccessibleusingathreemetre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty.
• Explaintheoperationtotheowner/occupier.
• Ensuretheremovableportionofthewarrantycardhasbeen completed and returned to Realcold Limited.
• Ensurethattheowner/occupierretaintheremainderofthe warranty card.
• Explaintotheowner/occupierthatthewarrantywillbevoid unless the unit is serviced annually.
Before making a warranty claim please consider the following:
• Checkandresetthepowersupply.
• Check theairconditioner’sremotecontrolsettings (payattention to timers and mode operation).
• Ensurefiltersanddrainsareclear.
• Checkeitherunitforobstructionsreducingairflow.
• Arethedoorsorwindowsopen,orarethereextrasources of heat in the room?
• Checktherefrigerantcharge.
To make a warranty claim:
• Ensurealldetailsonthewarrantycardhavebeencom-pleted and your warranty has been registered.
• Astheinstalleryouwillbeexpectedtoactastheserviceagent.
• CallyourlocalRealcoldbranchandquotethemodel,se-rial number and the warranty card number to obtain a warranty registration card. You may be asked to provide proof of purchase to establish warranty. (This authoriza-tion number is for administration purposes only and the company accepts no liability with the issue of this num-ber. Failure to obtain this number may delay settlement of your warranty).
• Return all damaged or defective parts ormaterials toyour local Realcold branch. Please fill in a goods return form, quoting you warranty authorization number. These parts are required for testing purposes.
Notes
Unless components are found to be defective and then ex-changed or repaired it is deemed by Realcold Limited that this was not covered under warranty and there will be a charge for non-warranty calls.
GREE AIR CONDITIONINGWARRANTY INFORMATION
AC52
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING WARRANTY INFORMATION
MHI AIR CONDITIONING WARRANTY INFORMATION
The Warranty on all Mitsubishi Heavy Industry product is covered by Mitsubishi Heavy Industries Air-Conditioners Australia Pty Ltd (MHI) and its New Zealand subsidiary. This warranty covers all MHI product purchased from Realcold Ltd and installed in New Zealand.
Please see MHI for their full warranty terms and conditions.
5 YEAR WARRANTY All Products Excluding the KX Range (service - see notes below)
5 YEAR WARRANTY KX Range Residential Installations (service - see notes below)
3 YEAR WARRANTY KX Range Commercial Installations (service - see notes below)
Contractor/Installer responsibilities:
• Install the air conditioner as per themanufacturer’s instructions
• Installation is to be done by a qualified tradesperson following best trade practices
• Theequipmentmustbesafelyaccessibleusingathreemetre ladder. If the unit is not accessible safely you may be required to arrange safe working conditions. This is not a cost to warranty
• Explaintheoperationtotheowner/occupier
• Explaintotheowner/occupierthatthewarrantywillbevoid unless the unit is serviced annually
Before making a warranty claim please consider the following:
• Checkandresetthepowersupply
• Check theairconditioner’sremotecontrolsettings (payattention to timers and mode operation)
• EnsureDrainsandFiltersareclear
• Checkeitherunitforobstructionsreducingairflow
• Arethedoorsorwindowsopen,orarethereextrasourc-es of heat in the room?
• ChecktheRefrigerantCharge
To make a warranty claim:
• YoumustbeaMHIserviceagenttomakeaclaim
• CallyourlocalbranchofRealcoldquotingthemodelandserial number plus a full description of the fault
• Pleasecheckthesystemforfaultcodes
• Pleasecheckthegaschargepriortocalling
• Youmaybeaskedtoprovideproofofpurchasetoestab-lish warranty.
• Realcoldwillassistwithtechnicalsupporttoestablishthefault and a course of action to remedy the fault
• Astheinstalleryouwillbeexpectedtoactastheserviceagent
• Shouldthefaultbeacceptedasawarrantythesupplyofspare parts and the cost of any labour will be met by MHI in accordance with their terms and conditions
Note
Unless components are found to be defective and then ex-changed or repaired it is deemed by MHI that this was not cov-ered under warranty and there will be a charge for non-war-ranty calls
AC53
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz. Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Air
Con
ditio
ning
AIR CONDITIONING WARRANTY INFORMATION
Air Conditioning WarrantyCoolbreeze
12 Months Parts Only on Evaporative Coolers
Eclipse
12 Months Parts Only on Air Curtain Models
Gree
5 Years Parts & Labour on all Models (Residential Installations Only)
2 Years Parts & Labour on all Models (Commercial Installations Only)
Refer to page AC51 for exceptions to the above
Mitsubishi (Warranty provided by MHI)
5 Years Parts & Labour on all Models (Except KX)
5 Years Parts & Labour on KX Range (Residential Installations Only)
3 Years Parts & Labour on KX Range (Commercial Installations Only)
See MHI for full details
Aspen Pumps
12 Months Parts Only on all Condensate Pumps
Note: The terms & conditions of warranty do not affect your rights under act 1, 2, 3.
AIR CONDITIONINGWARRANTY INFORMATION
Com
pone
nts
ComponentsAccumulators CA60
Brazing CB61
Brazing Torches CB62
Chemicals CC63Coil and Filter Cleaners CC63Thread Sealants CC63Miscellaneous Cleaners/ Disinfectants CC64Liquid Leak Detectors CC65
Compressors - Sealed Reciprocating CC66L’Unite R404a Medium Temp CC66L’Unite R404a Low Temp CC66L’Unite R134a Low Temp CC67L’Unite R134a Medium Temp CC67L’Unite Sealed Air Conditioning CC68L’Unite Sealed Compressors CC69L’Unite Sealed Rotary Compressors - Vertical CC72L’Unite Sealed CC73Solid State Relays CC74
Compressors - Copeland Scroll™ CC75Copeland Scroll™ Compressors - Introduction CC75Copeland Scroll™ - R22 Medium Temp CC76Copeland Scroll™ Compressors Accessories CC77
Compressors - Semi Sealed Reciprocating CC80Capacity Control CC82Accessories CC82
Compressors - Semi-Hermetic Screw CC83
Defrost Controls CD88Defrost Safety Thermostats CD89Defrost Heat Tape CD89Condensate Pans CD89
Driers CD90Sporlan Driers - Flare CD90Suction Line CD91Refillable Shells - Liquid Line CD92Refillable Shells - Suction Line CD92Directional CD93
Discharge Line Mufflers CD94
Electronic Controls CE95Refrigeration Controls CE95Accessories CE95Control Panels CE96
Fans CF97Fan Motors CF97Accessories CF97Fan Motor Assembly CF98Fan Blades CF99
Fittings CF100Brass Fittings - Flare CF100Copper Fittings CF102Fittings & Fasteners CF103Thermoplastic - Nylon CF105
Com
pone
nts
Components (continued)
Evaporator Mounting Kits - Nylon CF106Insulclamp CF107Studding Clip CF107BBJ Pipe Fittings CF107Locksets CF108Hinges CF108Style Spares - Efco CF108Accessories - Efco CF108Heat Exchangers CH109
Insulation CI110Tube Insulation CI110Sheet Insulation CI1111 Metre Adhesive Insulation CI111Roll Insulation CI111Insulation Tape CI112Accessories, Sealing, Jointing Compounds CI113
Lubricants CL114
OIL CONTROL SYSTEMS CO116Trax Oil Control Systems CO116Oil Reservoir And Accessories CO116Oil Separators CO118
PRESSURE CONTROLS CP119Dual Pressure Controls CP119Low Pressure Controls CP119High Pressure Controls CP119Differential Pressure Controls CP119Oil Protection Controls CP120Saginomiya Flow Switches CP120Pressure Control Accessories CP120Pressure Control Hoses CP120Pressure Controls - CB Series CP121Small Pressure Controls - Type ACB, LCB CP121
REFRIGERANT CR122
RECEIVERS CR124Vertical Receivers CR124Horizontal Receivers CR125
SIGHT GLASSES CS126
TEST EQUIPMENT CT127Service Manifold Sets CT127Charging Hoses CT127Gauges CT128Accessories CT128Couplers CT128Imperial Kwik - Couplers CT128Recovery System CT129Recovery Cylinders CT129Vacuum Pumps CT129
TOOLS CT130Electronic Vacuum Gauge CT130Charging Equipment CT130Leak Detectors CT130Mastercool Tools CT130Tube Cutters CT130
Com
pone
nts
Components (continued)
Tube Deburring Tool CT130Tube Expander Kit CT130Ratchet Wrenches CT130Tube Cutter Spares CT131Flaring & Swaging Tools CT131Tube Benders (lever type) CT132Bending Springs CT132Allen Key (hex key) CT132Pinch Off Tool CT133Oil Pump CT133Oil Injector CT133Fin Combs CT133Inspection Mirrors CT133Miscellaneous Tools CT134Temperature Test Equipment CT134Refractometers CT134Thermometers CT134
THERMOSTATS CT135
TUBE CT137
VALVES CV139Flica Orifices CV139Flica Thermostatic Expansion Type CV139Sporlan Q-Series Thermostatic Expansion Valves CV140Sporlan Orifices CV140Sporlan Thermostatic Elements CV140Sporlan Accessories CV140Sporlan J8 Thermostatic Expansion Valves CV141Cross Reference Table CV142Sporlan S and O-Series Valves CV143Sporlan TX Valve Replacement Heads CV143Sporlan Solenoid Valves (less coil) CV144Sporlan Solenoid Coils CV144Parker Hannifin SpA Solenoid Valves (complete with coils) CV145Parker Hannifin SpA Solenoid Valve Spares (replacement solenoid coils) CV145Pressure Regulators CV146Sporlan CDS Valves CV147Sporlan Hot Gas Bypass Valves CV147Sporlan Co2 Product Range CV147Mueller Ball Valves (two way) CV148Mueller Liquid Receiver Valves CV148Mueller Rotalock Valves CV148Mueller Hand Shut-Off Valves (packless line valves) CV149Mueller Pressure Relief Valves CV149Three Way Hand Shut-Off Valves CV149Check Valves - Refrigerants HFC & HCFC CV150Gaskets CV150Line Tap Valves CV151Schrader Valves / Access Ports CV151
VIBRATION ELIMINATORS CV152
Spares Spares153
COMPRESSOR AND CONDENSING UNIT WARRANTY CX167
CA60
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
ACCUMULATORS
Accumulators - Suction LineRealcoldStock No.
Model DescriptionkW Cap at Evap. Temp. -6°C
System Price$ Excl. GST
Size Connection R22 R404a/R507c
F0804 Virginia Accumulator 1/2" 1/2" ODS Vertical 4.6 4.8 53.09
F0805 Virginia Accumulator 5/8" 5/8" ODS Vertical 6.9 7.2 86.70
F0806 Virginia Accumulator 3/4" 3/4" ODS Vertical 9.2 9.6 86.70
F0807 Virginia Accumulator 7/8" 7/8" ODS Vertical 16.7 17.5 99.81
F0809 Virginia Accumulator 1.1/8" 1.1/8" ODS Vertical 27.0 28.3 155.04
F0811 Virginia Accumulator 1.3/8" 1.3/8" ODS Vertical 43.1 45.2 210.12
F0813 Virginia Accumulator 1.5/8" 1.5/8" ODS Vertical 65.3 68.4 252.96
F0121 Carly Vertical Accumulator 2.1/8” LCY 1817 S/MMS 125 130 1,213.80
F0125 Carly Vertical Accumulator 3.1/8” LCY 5025S 288 300 2,007.36
* These accumulators should not be used below -18°C without supplementary heating to ensure oil return - see information on Heater Elements below.
Factors for Determining Capacity
Evap. Temp. -18°C -30°C
Factor .68 .41
Note: To find kW capacity for the other evaporator temperatures, multiply factor X rating listed at -6C
Selection of a suction line accumulator should be made on the basis of the following capabilities:
• The accumulator should have an adequate liquid holding capacity - normally not less than 50% of the system charge.
• The accumulator should perform efficiently without excessive pressure drop to the system.
• The accumulator should return liquid at the proper rate and under a range of conditions of load.
• The selection of the suction line accumulator should not be based on line size, but on its ability to perform well within the limits described above. Consequently the suction line accumulator will not necessarily have the same connection size as the compressor suction line.
Heater Elements To Suit AccumulatorsElements must be used when operating under -18°C. The element adds heat to oil separators in order to prevent migration of refrigerant to the vessel during the off cycles of the compressor. Heater elements also add heat to suction line accumulators, to keep the oil warm, permitting oil return to the compressor on low temperature applications.
• For Heater Elements please refer to page CO118
Accumulator Dimensions - Suction LineRealcoldStock No.
Model Diameter (mm)
Overall Height (mm)
Height of Vessel (mm)
Fitting Size (mm)
Fitting Separating Centre - Centre (mm)
F0804 Accumulator 1/2" 76 209 184 1/2" 13 mm 41
F0805 Accumulator 5/8" 76 314 292 5/8" 16 mm 41
F0806 Accumulator 3/4" 76 321 292 3/4" 19 mm 41
F0807 Accumulator 7/8" 127 244 216 7/8" 22 mm 70
F0809 Accumulator 1.1/8" 127 376 340 1.1/8" 29 mm 70
F0811 Accumulator 1.3/8" 127 468 430 1.3/8" 35 mm 70
F0813 Accumulator 1.5/8" 152 556 514 1.5/8" 41 mm 75
F0121 LCY 1817 S/MMS 219 732 733 2.1/8 54 mm 114
F0125 LCY 5025 S 324 900 900 3.1/8 80 mm 155
Accumulator
F0084
Carly Accumulator
CB61
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
Accumulator Dimensions - Suction LineRealcoldStock No.
Model Diameter (mm)
Overall Height (mm)
Height of Vessel (mm)
Fitting Size (mm)
Fitting Separating Centre - Centre (mm)
F0804 Accumulator 1/2" 76 209 184 1/2" 13 mm 41
F0805 Accumulator 5/8" 76 314 292 5/8" 16 mm 41
F0806 Accumulator 3/4" 76 321 292 3/4" 19 mm 41
F0807 Accumulator 7/8" 127 244 216 7/8" 22 mm 70
F0809 Accumulator 1.1/8" 127 376 340 1.1/8" 29 mm 70
F0811 Accumulator 1.3/8" 127 468 430 1.3/8" 35 mm 70
F0813 Accumulator 1.5/8" 152 556 514 1.5/8" 41 mm 75
F0121 LCY 1817 S/MMS 219 732 733 2.1/8 54 mm 114
F0125 LCY 5025 S 324 900 900 3.1/8 80 mm 155
BRAZING
Brazing Alloy (Silver)RealcoldStock No.
Type Tip Colour Diameter x Length (mm)
Sold Per System Price$ Excl. GST
N0525 5% SBA Silver 2.5 x 750 Per Kilo 198.00
N0525A 5% SBA Silver 2.5 x 750 Per Stick 6.58
N1515 15% SBA Tan 1.5 x 750 Per Kilo 550.00
N1515A 15% SBA Tan 1.5 x 750 Per Stick 5.98
N1525 15% SBA Tan 2.5 x 750 Per Kilo 550.00
N1525A 15% SBA Tan 2.5 x 750 Per Stick 13.80
N1530 15% SBA Tan 3.0 x 750 Per Kilo 550.00
N1530A 15% SBA Tan 3.0 x 750 Per Stick 21.98
N3415 34% SBA Green 1.5 x 750 Per Kilo POA
N3415A 34% SBA Green 1.5 x 750 Per Stick POA
N5515 55% SBA Dark Green 1.5 x 750 Per Kilo POA
N5515A 55% SBA Dark Green 1.5 x 750 Per Stick POA
N5530 55% SBA Dark Green 3.0 x 750 Per Kilo POA
N5530A 55% SBA Dark Green 3.0 x 750 Per Stick POA
N5020 General Purpose Flux for Silver Brazing Alloy 250gm Pot 35.75
• 5% Silver (Silver Tip) Suitable for copper to copper and copper alloys. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.
• 15% Silver (Tan Tip) Suitable for copper to copper and copper alloys, giving excellent ductility for high stressed joints. No flux required for copper to copper. Use flux for copper alloys. Cadmium free.
• 34% Silver (Green) GP alloy for general engineering metals giving excellent fluidity with excellent gap filling qualities. Flux should be used. Cadmium free.
• 55% Silver (Dark Green Tip) Excellent alloy, giving high strength with excellent capillary action. Good ability to fill fine gaps. Cadmium free.
• Realcold recomend the use of General Purpose Flux, N5020, when brazing non-ferrous metals.
Brazing AccessoriesRealcoldStock No.
Description Sold Per System Price$ Excl. GST
N5022 La-Co Aluminium Repair Kit Complete with flux paste, (for easy soldering of aluminium to copper).
Kit 49.42
N0003 MA-Line Sand Cloth 1.1/2” 9 metre 11.62
N0005 MA-Line Sand Cloth 1.1/2” 22 metre 28.17
N0007 MA-Line Mesh Cloth 1.1/2” 45 metre 16.01
N0009 MA-Line Open Mesh Cloth 1.1/2” 9 metre 28.71
N0010 Emery Tape 80 grit 50 metre Roll 67.32
N0015 Emery Tape 180 grit 50 metre Roll 79.46
N5022 T0119
N0010
CB62
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
BRAZING TORCHES
Bernzomatic Self-Igniting Brazing TorchesRealcoldStock No.
Description System Price$ Excl. GST
N6006 BERNZOMATIC Self-Igniting Brazing Torch
A simple press of the piezo igniter gives instant flame for brazing. The high performance pressure regulator and swirl flame allows higher temperatures than conventional torches. Superior performance in cold weather.
116.74
N6010 Brazing Turbo Set 200 Excl. Gas
CB66 Brazing Torch Description: A light weight welding and brazing system with disposable gas cylinder’s. Each kit contains:
• MetalStoragecarrier
• OxygenpressurereducerswithHPgaugeandflashbackarrestors
• MappPropressurereducerwithLPgaugeandflashbackarrestors
• 2mhoseswithconnections
• Handpiecewith160Inozzle
• 4additionalnozzles63–100–250–315I
• Protectivegoggles
• Multi-purposespanner
• Flintlighter
• 2xWeldingRod
500.00
N6050 Gas Canister (Disposable) 30.90
N6011 1L Oxygen Cylinder 95.00
Some helpful hints on using your Bernzomatic:
• NOTE - USE only IN WELL VENTILATED AREAS
• DO NOT ADJUST THE FLAME SO LOW THAT THE STEEL BURNER TIP BECOMES RED HOT OR DAMAGE TO THE TIP MAY RESULT.
Q. Why does my torch head break at the air holes?
A. In order to ensure that the cylinder does not break or explode if the torch is accidentally dropped or abused, BernzOmatic torches are designed to break safely at the air holes.
Q. Why will my torch not stay lit when tipped upside down?
A. When a non regulated brass torch is tipped upside down, the liquid propane in the torch works its way through the torch and blows out the flame
Q. Why in cold weather do I only get a small flame out of my torch?
A. The size of the torch flame varies with the pressure in the gas cylinder. When it is very cold there is only a small amount of gas pressure in the cylinder.
Q. Why is my torch hard to light?
A. Most torches light better when the valve is just cracked open, and there is a small gas flow.
N6010 Brazing Turbo Set 200
CC63
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
CHEMICALS
Coil and Filter CleanersFoam Brite Condenser Coil Cleaner - Non Acidic
Penetrating non-acidic foaming action lifts and pushes contaminants and oxide off coils, including stubborn grease, tars and dirt, so that they can be rinsed away with water. Works in less than 5 minutes.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0707 Greenleaf Foam Brite 1L spray 22.08
N0708 Greenleaf Foam Brite 5L 55.18
N0726 Greenleaf Non Caustic 5L 61.51
Evaporator Coil Cleaner - Self Rinsing
A clean evaporator is the first step in ensuring maximum compressor efficiency. Greenleaf Evaporator Coil Cleaner is a safe, biodegradable alkaline self rinsing coil cleaner. It has a safe, non acidic formula which can be used indoors. NZFSA Approved C101.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0727 Greenleaf Evaporator Coil Cleaner 1L spray 22.08
N0728 Greenleaf Evaporator Coil Cleaner 5L 55.18
N0729 Greenleaf Evaporator Coil Cleaner 20L 174.42
Clean-N-Safe ™
A non-acid, non-caustic, non-corrosive evaporator and condenser coil cleaner. It is completely biodegradable and is safe for use around people, animals, aquatic life, and vegetation, USDA-H1.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0720 Clean-N-Safe ™ 3.8L 59.36
N0721 Clean-N-Safe ™ 568gm Aerosol spray can
27.34
CF-20 Internal Coil System Cleaner & Acid Neutraliser
Replaces R11 as a flushing agent. Environmentally safe, biodegradable interior coil cleaner for refrigeration and air conditioning systems. To clean interior coils after a compressor failure or burn-out and to remove mineral oil residue in preparation for retrofitting.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0820 Internal System Cleaner CF20 1L spray 123.42
® ™ Registered trade mark of The Rectorseal Corporation.
Thread SealantsRealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0058 Nylog Blue 30ml POE Oil Sys. each 20.10
N0059 Nylog Red 30ml Mineral Oil Sys. each 20.10
N0063 Leak-Lock Tube 1oz tube 9.80
N0065 Leak-Lock Brush Top Plastic Jar 4oz tube 21.15
N0069 Teflon Thread Seal Tape 12 mm x 10m roll 3.00
Rectorseal
CC64
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
CHEMICALS
Miscellaneous Cleaners/ Disinfectants Eucalyptus All Purpose Cleaner & Degreaser
A powerful all purpose cleaner & degreaser, with the added cleaning, deodorising and disinfecting power of natural eucalyptus oil. Sold as a concentrate. MAF approval C32.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0752 Greenleaf All Purpose Cleaner 1L spray 22.65
N0753 Greenleaf All Purpose Cleaner 5L 62.33
N0754 Greenleaf All Purpose Cleaner 20L 222.77
Ice Machine Cleaner - Nickel Safe
Biodegradable cleaner, specially formulated for removing scale deposits from ice machines with nickel or tin plated evaporators. Easy to use whilst providing a thoroughly clean machine. Sold as a concentrate.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0712 Greenleaf Ice Machine Cleaner 1L 19.87
N0713 Greenleaf Ice Machine Cleaner 5L 55.74
KO Dirt Blaster
High pressure cleaner- degreaser for filters, motors, relays, small condensers, etc. Blasts off dirt and grease without a rinse.Quick drying, electrically safe.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0734 Stewart Hall KO Dirt Blaster - Aerosol 568gm 33.10
Coil And Duct Disinfectant
An all in one spray that disinfects all surfaces, whilst also deodorising. A blend of Deodoriser and EPA Registered Hospital Grade QUAT Disinfectant kills a wide range of pathogens and sodium hypochlorite to kill legionaella pneumophila, and most air borne pneumonia bacteria.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0746 Greenleaf Coil & Duct Disinfectant 1L spray 19.33
N0747 Greenleaf Coil & Duct Disinfectant 5L 48.57
Germicidal cleaner, deodorizer and disinfectant for ducts, coils, air filtering equipment and most other hard surfaces. Kills disease causing bacteria, as well as mould, fungi, and mildew. Helps cure bad odours, and Sick Building Syndrome reactions of sensitive people.
N0748 Greenleaf Air Filter Cleaner 1L 23.18
N0749 Greenleaf Air Filter Cleaner 5L 56.76
Actabs
Prevent drain pan overflow and odours. Patented dispenser avoids monthly applications. Lasts about 5 months. Actabs are placed in the drain pan.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0703 Stewart Hall Actabs Self-dispensing pack of 6 20.45
N0704 Stewart Hall Actabs JR 400g Bottle - approx. 200 tabs 106.46
CC65
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
CHEMICALS
Miscellaneous ChemicalsAcid-Away®
A unique chemical treatment for use in air conditioning and refrigeration systems that have experienced a burn out or operating systems that are showing a build-up of acid content. May be used in hermetic or semi hermetic compressors that operate with standard CFC or HCFC refrigerants using mineral and alkylbenzene type refrigeration oils.
Acid-Away® has been tested in accordance with ANSI/ ASHRAE standards 86-1983 and 97-1989, along with various ASTM standards.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0800 Acid-Away® for Mineral/ Alkylbenzene Oils
(not suitable for polyolester oils).
118ml bottle (4oz) 76.68
N0808 Acid-Away® for Polyolester Oils 118ml bottle (4oz) 83.86
Acid Test Kits
Oil should be tested immediately after removal from unit.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
T0117 ETK Refrigeration Oil Acid Test Kit - Polyolester Oil 118ml bottle (4oz) 31.06
T0118 TKO Refrigeration Oil Acid Test Kit 118ml bottle (4oz) 24.31
Coil Protectant
Designed to protect coils and cabinets from corrosion.
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
N0062 Blue Coil Guard 600ml 83.33
Liquid Leak DetectorsBig Blu Leak Reactant
RealcoldStock No.
Description Pack Size System Price$ Excl. GST
T0440 Big Blu leak Reactant Complete With Spray Applicator 0.947 L 20.45
T0442 Big Blue Leak Reactant 3.785 L 77.22
® ™ Registered trade mark of The Rectorseal Corporation.Visit www.rectorseal.com and www.greenleaf.co.nz for additional product information and MSDS Data Sheets.
ACTABS
Actabs with its EPA registered biocide eliminates or prevents most blockages in air conditioning and refrigeration drain lines due to the buildup of bacterial slime, rust, scale, sludge, air bourne dust, silty and other solids.
• Unique automatic metering dispenser
• EPA Registered
• Prevents Costly Water Overflow Damage
• Eliminates Bacteria Casused Bad Odours
• Can be used in Computer Rooms
CC66
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED RECIPROCATING
L’Unite R404a Medium TempColumn Key: D = Displacement, OC = Oil Charge, FIG = Picture # Control = Cap/TEV for all models listed FIG = Picture # on page CC72
RealcoldStock No.
Model Fig. Nom. Hp
Appl. Watts H (mm) Displ. (cm3)
OC (L) System Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +15°C
Domestic - Commercial 220/240 Volt 50 Hz Single Phase
C7010 AEZ4425Z Fig 1 1/5 HT 198 263 341 432 587 787 186 4.50 .45 255.00
C7012 AEZ4430Z Fig 1 1/4 HT 258 346 441 550 741 1010 186 5.70 .45 306.00
C7014 AEZ4440Z Fig 1 1/3 HTW 357 462 590 743 1004 1342 199 7.55 .45 410.04
C7016 CAE9450Z Fig 2 3/7 HTW 434 567 731 927 1270 1729 212 9.40 .45 459.00
C7020 CAE9460Z Fig 2 1/2 HTW 500 663 857 1092 1517 2139 212 11.30 .45 467.16
C7021 CAE9470Z Fig 2 1/2 HTW 613 803 1031 1305 1804 2535 215 13.30 .45 475.32
C7022 CAJ9480Z Fig 3 5/8 HTW 690 911 1173 1487 2060 2903 271 15.20 .89 732.36
C7030 CAJ9510Z Fig 3 1.0 HTW 878 1151 1476 1866 2579 3628 282 18.30 .89 767.04
C7032 CAJ9513Z Fig 3 1.1/8 HTW 984 1349 1770 2263 3145 4418 282 24.20 .89 804.78
C7036 CAJ4517Z Fig 3 1.1/4 HT 1191 1614 2104 2677 3697 5158 282 25.95 .89 828.24
C7038 CAJ4519Z Fig 3 1.1/2 HT 1592 2121 2739 3468 4780 6683 282 34.45 .89 879.24
*C7040 FH4524Z Fig 4 2.0 HT 1587 2290 3110 4073 5736 8204 354 43.50 1.33 1,095.48
*C7042 FH4531Z Fig 4 2.1/2 HT 2165 3029 4029 5205 7412 10325 370 56.65 1.33 1,179.12*C7040 and *C7042 are available both single and three phase - please state when ordering.
Commercial 400 Volt 50 Hz Three Phase
*C7048 TFH4522Z Fig 4 1.3/4 HT 1322 1924 2640 3501 5066 7312 354 39.95 1.33 986.34
*C7050 TFH4524Z Fig 4 2.0 HT 1587 2290 3110 4073 5736 8204 354 43.50 1.33 1,010.82
*C7054 TFH4531Z Fig 4 2.1/2 HT 2165 3029 4029 5205 7412 10325 354 56.65 1.33 1,064.88
*C7058 TFH4540Z Fig 4 3.0 HT 2948 4023 5263 6716 9185 12764 370 74.25 1.33 1,109.76
*C7070P^ TAG4553Z Fig 5 4.1/2 HT 3115 4537 6240 8302 12151 17756 381 100.70 1.96 1,468.80
*C7074P^ TAG4561Z Fig 5 5.0 HT 3720 5305 7171 9403 13438 19488 381 112.50 1.96 1,654.44
*C7082P^ TAG4573Z Fig 5 6.1/4 HT 5167 7018 9245 11946 16908 24235 393 134.80 1.96 1,828.86
L’Unite R404a Low TempRealcoldStock No.
Model Fig. Nom. Hp
Appl. Watts H (mm) Displ. (cm3)
OC (L) System Price$ Excl. GST
-35°C -30°C -23.3°C -20°C -15°C -10°C
Commercial 220/240 Volt 50 Hz Single Phase
C0532 AEZ2415Z Fig 1 3/8 LT 160 231 355 429 560 712 199 8.10 .45 343.74
C0545 CAE2417Z Fig 6 1/2 LT 161 280 460 557 716 891 212 11.30 .45 395.76
C0551 CAE2420Z Fig 6 1/2 LT 232 357 547 654 836 1047 212 12.54 .45 346.80
C0554 CAE2424Z Fig 6 5/8 LT 291 413 630 759 990 1266 215 15.00 .45 489.60
C0573 CAJ2432Z Fig 3 3/4 LT 310 478 765 935 1247 1593 271 18.30 .89 657.90
C0580 CAJ2446Z Fig 3 1 LT 546 799 1194 1443 1848 2322 282 26.15 .89 748.68
C0592 CAJ2464Z Fig 3 1.1/2 LT 760 1096 1605 1887 2412 3030 282 34.45 .89 792.54
*C0599 FH2480Z Fig 4 2 LT 738 1319 2183 2662 3551 4505 370 53.20 1.625 1,122.00
C0600 FH2511Z Fig 4 3 LT 1380 2016 3135 3796 4931 6303 370 74.25 1.625 1,015.00
Commercial 400 Volt 50 Hz Three Phase
*C7120 TFH2480Z Fig 4 2.0 LT 738 1319 2183 2662 3551 4505 354 53.20 1.625 1,083.24
*C7122P^ TFH2511Z Fig 4 3.0 LT 1380 2016 3135 3796 4931 6303 354 74.25 1.625 1,208.70
*C7126P^ TAG2516Z Fig 5 4.0 LT 1765 2704 4356 5335 7043 9038 381 112.50 1.96 1,645.26
*C7128P^ TAG2522Z Fig 5 5.0 LT 2395 3542 5522 6688 8711 11062 393 134.80 1.96 1,777.86
All above compressors use Polyolester Oil and require fan cooling. Use Acid-Away to solve burn-outRefer to Realcold Technical Department for Tandem Compressor packages up to 12HP. and acid build up situations.* These items include crankcase heater and oil sight glass. P^ These items include an oil level sight glass and connections for oil and pressure equalising lines.
CC67
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED RECIPROCATING
L’Unite R134a Low TempColumn Key: D = Displacement, OC = Oil Charge, FIG = Picture # Control = Cap/TEV for all models listed FIG = Picture # on page CC72-CC73
RealcoldStock No.
Model Fig Nom. Hp
Appl. Capacity (w) @ 32° Ambient H (mm)
D (cm3)
OC (L) C Control System Price$ Excl. GST
-35°C -30°C -23.3°C -20°C -15°C -10°C
Domestic - Commercial 220/240 Volt 50 Hz Single Phase
C0501 AZ1335Y Fig 13 1/8 LT 42 58 89 108 141 180 169 4.0 .40 S Cap 233.58
C0513 THB1340Y Fig 13 1/8 LT 44 66 104 126 163 205 169 4.23 .25 S Cap 240.00
C0508 THB1365Y Fig 5 1/5 LT 68 96 147 177 229 289 169 6.1 .27 S Cap 205.02
C0522 AEZ2380Y Fig 1 1/4 LT 94 144 223 267 338 417 199 9.4 .45 SOC Cap/TEV
328.44
C0530 CAE2410Y Fig 7 1/3 LT 92 151 259 324 436 566 199 12.00 .45 F Cap/TEV
377.40
C0534 CAE2412Y Fig 7 3/8 LT 96 174 306 382 514 663 199 14.20 .45 F Cap/TEV
392.70
L’Unite R134a Medium TempRealcoldStock No.
Model Fig Nom. Hp
Appl. Watts H (mm)
D (cm3)
OC (L) C Control System Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +15°C
Domestic - Commercial 220/240 Volt 50 Hz Single Phase
C0511 THB4415YFZ Fig 13 1/8 HT 123 160 206 262 363 502 169 4.23 .27 S Cap/TEV
266.22
C0512 THB4419YFZ Fig 13 1/6 HT 149 194 251 319 439 602 172 5.20 .27 S Cap/TEV
288.66
C0518 AEZ4425Y Fig 1 1/5 HT 185 260 350 455 635 866 186 7.60 .45 F Cap/TEV
313.14
C0525 AEZ4430Y Fig 1 1/4 HT 245 328 432 558 777 1065 199 8.80 .45 F Cap/TEV
335.58
C0535 CAE4440Y Fig 7 1/3 HT 310 421 561 731 1026 1413 199 12.00 .45 F Cap/TEV
387.60
C0536 CAE4448Y Fig 6 3/8 HT 403 530 693 892 1242 1705 212 14.20 .45 F Cap/TEV
419.22
C0537 CAE4456Y Fig 6 3/7 HT 458 604 787 1009 1396 1904 212 16.20 .45 F Cap/TEV
450.84
C0550 CAJ4461Y Fig 3 1/2 HT 475 642 856 1115 1569 2246 258 18.30 .89 F Cap/TEV
596.70
C0575 CAJ4492Y Fig 3 3/4 HT 584 871 1215 1617 2295 3303 271 25.95 .89 F Cap/TEV
703.80
C0590 CAJ4511Y Fig 3 1 HT 878 1227 1654 2160 3026 4165 282 32.70 .89 F Cap/TEV
793.56
**C0593* FH4518Y Fig 4 1.1/2 HT 1036 1650 2371 3200 4583 6333 330 53.20 1.33 F Cap/TEV
1,013.88
**C0595* FH4525Y Fig 4 2 HT 1667 2343 3201 4239 6053 8442 354 74.25 1.33 F Cap/TEV
1,370.88
Commercial 400 Volt 50 Hz Three Phase
**C0594* TFH4518Y Fig 4 1.1/2 HT 1036 1650 2371 3200 4583 6333 354 53.20 1.33 F Cap/TEV
1,242.36
**C0596* TFH4525Y Fig 4 2 HT 1667 2343 3201 4239 6053 8442 354 74.25 1.33 F Cap/TEV
1,330.08
All above compressors use Polyolester oil.* Please state option when ordering, ie 1 phase or 3 phase.** Includes crankcase heater.
CC68
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED RECIPROCATING
L’Unite Sealed Air ConditioningRated in Watts at +7.2°C SST/+54.5°C SCT, for capillary use only.
RealcoldStock No.
Model Fig Watts H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST
Air Conditioning R22 220/240 Volt 50 Hz Single Phase
C0110 AJ5510F Fig 10 2447 271 18.60 M .89 F 677.28
C0111 AJ5512E Fig 10 2909 271 21.75 M .89 F 684.42
C0123 AJ5513E Fig 10 3214 271 24.20 M .89 F 698.70
C0124 AJ5515E Fig 10 3632 271 25.95 M .89 F 732.36
C0126 AJ5518E Fig 10 4555 282 32.70 M .89 F 732.36
C0127 AJ5519E Fig 10 4780 282 34.45 M .89 F 773.16
C0129 FH5524F Fig 11 5718 330 43.50 M 1.33 F 954.72
C0138 FH5527E Fig 11 6487 330 49.10 M 1.33 F 963.90
L’Unite Sealed Tandem Compressor Kit Commercial Medium TempRealcoldStock No.
Model Fig WATTS @ -5°C SCT H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST
R22 R404a
L’Unite Tagd Twin Compressors R22/R404a 400 Volt 50Hz Three Phase
C7105 TAGD4612Z Fig 12 16368 14342 565.0 225 POE 1.96 F 4,056.54
Features of the Tandem System
• Twin compressor configuration enable a more precise control of the system capacity to match the cooling demand and thereby the number of starts to a minimum to improve reliability.
• Capacity control - cycle one compressor off at low load conditions for power saving.
• Sequence start up of compressors reducing start up current.
• 50% redundant capacity in the event of one compressor failing.
CC69
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’Unite Sealed - Introduction L’Unite Hermetique is 100% owned by Tecumseh, USA. Hermetic compressors are manufactured in Europe and marketed by Tecumseh Europe.
Where applicable all L’Unite compressors come complete with full electrics and rotalock valves included in cost. FH - TFH - TAG & *TAGD compressors come complete with crankcase heaters and oil level sight glasses. NB. A/C compressors may not have accessories attached.
Tecumseh Europe Rating ConditionsApplications Ambient Evaporator outlet and return
gas super heatedCondensing Entering exp. valve
Low Temperature domestic and commercial refrigeration (LBP) +32˚C +32˚C +54.5˚C +32˚C
Other Applications (M/HBP-AC) +35˚C 11K +54.5˚C +46.1˚C
Note: Visit www.tecumseh-europe.com for additional product information.
COMPRESSORS - SEALED RECIPROCATING
T/FH
FH
RK
CAJ
TAGD*Dual Compressor
Merits of TAGD
• capacitycontrolaccordingtothesystemdemands
• reducedenergyconsumptionduetolowtorquestartandsequencestarting
• reducednumberofstarts.
Terminology
LT (LBP) Low Temperature - Evaporating Temp Range -40˚C / -10˚C
HT (HBP) High Temperature - Evaporating Temp Range -15˚C / +15˚C
HT W (M/HBP) High Temperature Wide Range - Evaporating Temp Range -25˚C / +15˚C
AC Air Conditioning - Evaporating Temp Range -10˚C / +10˚C
S/F Static Cooled/Fan Cooled
F Fan Cooled
SOC Static with oil cooler
CAP Capillary Controlled
CAP/TEV Capillary or Expansion Valve Controlled
For suitable compressor oils, please see Lubricants Section
M Mineral Oil
AB Alkylbenzene Oil
P Polyolester Oil
Warranty: See Warranty section at front of catalogue for more details.
L’Unite Sealed Compressors
CC70
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED RECIPROCATING
Figure One Figure ThreeFigure Two
Figure Four Figure SixFigure Five
Figure Seven Figure Eight
Specified compressor heights are indicative of series dimensions.
Certain model heights vary from specification.
Please consult Realcold if the com-pressor height is crucial.
Visit www.tecumseh-europe.com for additional product information.
CC71
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED RECIPROCATING
Figure Nine Figure ElevenFigure Ten
Figure Twelve Figure FourteenFigure Thirteen
Figure Fifteen Figure Sixteen
Specified compressor heights are indicative of series dimensions.
Certain model heights vary from specification.
Please consult Realcold if the com-pressor height is crucial.
Visit www.tecumseh-europe.com for additional product information.
CC72
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED ROTARY
L’Unite Sealed Rotary Compressors - VerticalColumn Key: D = Displacement
RealcoldStock No.
Model Fig Watts H (mm) D (cm3) OT OC (L) C System Price$ Excl. GST
L’Unite Sealed R22 220/240 Volt 50Hz Single Phase
C7210 RK5512E Fig 16 2771 290 16.3 M 0.422 F 575.28
C7216 RK5515E Fig 15 3600 312 21.4 M 0.452 F 659.94
C7218 RK5518E Fig 15 4195 312 24.4 M 0.452 F 696.66
L’Unite Sealed Rotary HGA Compressors - Horizontal - R404a Medium TempRealcoldStock No.
Model Nom. Hp Appl. Watts Displ. (m3/h)
System Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +15°C
L’Unite Sealed R404a 220/240 Volt 50 Hz Single Phase
C7304 HGA4467Z 3/7 MT 679 847 1047 1283 1557 1872 9.5 683.40
C7308 HGA4480Z 1/2 MT 825 1017 1252 1530 1851 2212 11.5 888.42
C7312 HGA4492Z 1/2 MT 905 1133 1398 1706 2060 2468 12.7 902.70
C7316 HGA4512Z 5/8 MT 1163 1438 1770 2160 2609 3118 16.1 1,271.94
L’Unite R404a Low TempRealcoldStock No.
Model Nom. Hp Appl. Watts Displ. (m3/h)
System Price$ Excl. GST
-30°C -23.3°C -20°C -15°C -10°C
L’Unite Sealed R404a 220/240 Volt 50 Hz Single Phase
C7336 HGA2426Z 3/8 LT 465 630 720 883 1075 9.5 636.48
C7340 HGA2432Z 1/2 LT 566 766 873 1066 1291 11.5 683.40
C7344 HGA2436Z 1/2 LT 610 826 944 1158 1408 12.7 820.08
C7348 HGA2446Z 5/8 LT 789 1073 1227 1507 1838 16.1 834.36
Vertical Compressors Horizontal Compressor cross section Horizontal Compressor
Contact your local Realcold branch for our full range of Air Conditioning Rotary Compressors.
L’Unite R134a Medium TempRealcoldStock No.
Model Nom. Hp Appl. Watts Displ. (m3/h)
System Price$ Excl. GST
-15°C -10°C -5°C 0°C +7.2°C +15°C
L’Unite Sealed R134a 220/240 Volt 50 Hz Single Phase
C7320 HGA4445Y 1/4 MT 392 493 618 770 954 1173 9.5 588.54
C7324 HGA4450Y 1/3 MT 501 625 778 963 1184 1445 11.5 615.06
C7328 HGA4460Y 1/3 MT 537 677 844 1045 1287 1576 12.7 650.76
C7332 HGA4476Y 3/7 MT 696 870 1086 1349 1662 2030 16.1 683.40
CC73
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED ROTARY ACCESSORIES
L’Unite SealedRealcoldStock No.
Description System Price$ Excl. GST
C1900 Terminal box cover to suit AEZ compressor 9.49
C1901 Overload cover to suit CAJ compressor 13.67
C1902 Terminal box to suit CAJ compressor 62.02
C1903 Electrical Box for TAGD Packs 148.92
C1930 Sight Glass Kit to suit FH, TFH, TAG & TAN compressors 63.04
Rotalock Valves - L’Unite ReceiversRealcoldStock No.
Connection (mm)) Tube SizeOD. (mm)
System Price$ Excl. GST
C1922 19.1 6.3 87.21
C1923 19.1 9.5 87.21
C1908 23.5 6.3 84.05
C1909 23.5 9.5 84.05
Crankcase Heaters RealcoldStock No.
Model Description System Price$ Excl. GST
C1001 H-101 54W 240 Volt
Suitable for L’Unite AH and TAH compressors
Suitable for Kirby AH, AG and CL compressors
40.49
C1003 H-102 60W 240 Volt
Suitable for L’Unite AJ and CAJ compressors
Suitable for Kirby AJ compressors
48.86
C1005 Crankcase Heater to suit FH, TFH & TAG Series 90.37
C1007 Crankcase Heater to suit TAN Series - 2 per kit 145.86
Maximum Torque Settings Nm (cm Kg)
Valve Spindle
Small Valves 11.7 (115)
19 mm square body 14 (138)
22 mm square body 21 (207)
28 mm square body 35 (344)
Valve cap on Rotalock
¼” (7/16” thread) 14 (138)3/8” (5/8” thread) 30.5 (300)
½” (3/4” thread) 45 (442)
¾” (7/8” thread) 59 (580)
Rotalock valves on compressors and receivers (with joint)
¾” thread 56.5 (553)
1” thread 84.5 (829)
1 ¼” thread 141 (1382)
1 ½” thread 197 (1935)
1 ¾” thread 317 (3110)
Connections on parallel mounted versions
1 ¾” thread 107 (1050)5/8” thread 45 (442)
Sight Glass
1 1/8” 51 (500)
Rotalock Valves - L’Unite CompressorsRealcoldStock No.
Connection (mm)
Tube SizeOD. (mm)
Suits - Suction Suits - Discharge System Price$ Excl. GST
C1911 23.5 12.7 CAJ2446Z, CAJ4416Y, CAJ4492Y, CAJ9480Z
TFH4524Z, TFH4540Z, (T)FH2480Z, FH2511Z, FH4518Y, FH4525Y, (T)FH4513Z, TFH2511Z
89.30
C1912 23.5 15.9 CAJ2464Z, CAJ4511Y, CAJ4517Z, CAJ4519Z, CAJ9510Z, CAJ9513Z
- 89.30
C1913 31.8 15.9 (T)FH2480Z, (T)FH2511Z, FH4518Y, (T)FH4524Z, (T)FH4525Y
TAG2516Z, TAG2522Z, TAG4553Z, TAG4561Z, TAG4573Z
105.06
C1916 31.8 22.2 (T)FH4531Z, TAG2516Z, TAG4553Z, TFH4540Z
- 151.98
C1917 31.8 28.6 TAG2522Z, TAG4561Z, TAG4573Z - 161.16
CC74
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEALED ROTARY ACCESSORIES
Solid State Relays RealcoldStock No.
Model Description HP/Voltage System Price$ Excl. GST
C4000 ICG 220 220V Solid State Relay 1/12 HP through 1/2 HP 22.08
C4005 PO 230 230V Solid State Relay 1/12 HP through 1/2 HP 20.50
C4020 RO-82 220V Relay & Overload 1/12, 1/10, 1/8 HP 43.61
C4015 RO-62 220V Relay & Overload 1/6, 1/5 HP 43.61
C4010 RO-42 220V Relay & Overload 1/4, 1/3 HP 43.61
C4025 RSC-20 220V Solid State Start Relay & Capacitor (43 - 52MFD) 54.67
C4030 RCO-820 230V 3 n' 1 Start Relay 1/12, 1/10, 1/8 HP 59.36
C4035 RCO-620 230V 3 n' 1 Start Relay 1/6, 1/5 HP 59.36
C4040 RCO-420 230V 3 n' 1 Start Relay 1/4, 1/3 HP 59.36
C4050 SPP-5 230V Starter Pow-R-Pak PSG A/C 4000-120000 BTU 45.19
C4062 APR-5 Universal Replacement Relay Pick up voltage 130V-370V 115.26
Applications For Solid State Relays
ICG Series:
• One size for all compressors 1/12 through 1/2 HP.
• Will replace most current relays.
• Can be used with or without start capacitor.
PO Series:
• One size for all compressors 1/12 through 1/2 HP.
• Replaces all push-on current type relays.
• For use on compressors with “pin type” terminals.
• Can be used on all capacitor and non-capacitor start motors.
• Lowest resistance solid state relay.
• Will restart a balanced system within one minute.
RO Series:
• Relay and overload in one combination unit.
• Pre-wired for fast, simple installation.
• Superior locked rotor protection eliminates start winding overheating.
• Replaces all hermetic compressor relay and overload units 1/12 through 1/3 HP.
• Can be used in conjunction with a start capacitor.
RSC Series:
• One size for all compressors 1/12 through 1/2 HP both domestic and commercial.
• A combined solid state starting relay and capacitor.
• Completely pre-wired.
• Replaces current type relays.
• Provides added boost for hard start and unbalanced systems.
• Prevents low voltage starting problems. (No additional wires required.)
RCO Series:
• The 3 n’ 1 Start Relay replaces all three electrical components, Relay, Overload, and Start Capacitor, on all capillary systems.
• Completely pre-wired.
• Installs quickly and easily, simply by pushing on 3 female pin terminals.
RO
RSC
RCO
RO
ICG
PO
APR5
CC75
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - COPELAND SCROLL™
Copeland Scroll™ Compressors - IntroductionCopeland Scroll™ Compressors are manufactured by Emerson Climate Technologies.
With its European Headquarters based in Germany and manufacturing plants all around Europe, Emerson Climate Technologies is the world’s largest provider of HVAC/R solutions, delivering simple answers for commercial, industrial, and residential applications.
Standard Copeland Scroll™ Compressor unit includes:
• Compressor filled with ester oil
• Rotalock connections
• Oil sight glass
• Schraeder connection for oil fill or drain
• Rubber mountings
• Electronic protection module on all compressors from 7.5 to 15hp
Features & Benefits
• Designed to meet the specific needs in refrigeration (medium and low temperature applications).
• Wide range of operations (2 to 15hp for all R404a, R134S and R22 applications).
• High efficiencies all year round (continuous scroll flank contact maintained by centrifugal force minimizing gas leakage, maximising efficiency).
• Capacity control (modulation range is continuous from 10 to 100%).
• Compactness (Small footprint with reduced weight by up to 50% compared to standard semi-hermetic compressors).
• Robustness and reliability (Stringent qualification tests ensure maximum reliability, Teflon coated bearings, fewer parts).
• Compressor protection (All 2 to 6HP compressors are supplied with internal thermal protectors and all 7.5hp to 15hp models feature an electronic module).
• Smooth operation (Designed with a discharge check valve).
• Asercom certified performance data (Compressor delivers performance defined and published by the manufacturer via simulative data testing performed by experts and regular measurement at independent bodies.
ZB11MCE ZB92KCE ZB38KC ZB19KC ZBD45
CC76
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - COPELAND SCROLL™
Copeland Scroll™ - R22 Medium TempColumn Key: FIG = Picture #, D = Displacement, W = Weight for all models listed
RealcoldStock No.
Model Fig. Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Weight (Kg)
System Price$ Excl. GST
R22
- 15°C - 10°C -5°C 0°C + 5°C +7.2°C
Air Conditioning - 220/240 Volt 50 Hz Single Phase
CS0044 ZR28K3E-PFJ Fig 2 2.5 2880 3660 4530 5530 6650 7290 6.80 27 905.76
CS0047 ZR36K3E-PFJ Fig 2 3.0 3550 4430 5460 6620 7940 8690 8.60 29 991.44
CS0049A ZR42K3E-PFJ Fig 2 3.5 4190 5220 6410 7790 9370 10270 9.90 30 1,106.70
CS0050 ZR47K3E-PFJ Fig 3 4.0 5030 6320 7790 9470 11370 12435 11.0 31 1,245.42
CS0054 ZR68KCE-PFJ Fig 3 5.5 6720 8020 10210 12750 14160 15970 6.1 40 1,402.50
Air Conditioning - 380/420 Volt 50 Hz Three Phase
CS0052 ZR61KCE-TFD Fig 3 5.0 5800 7420 9330 11500 13900 15200 14.4 36 1,318.86
CS0060 ZR68KCE-TFD Fig 3 5.5 6720 8020 10210 12750 14160 15970 16.2 39 1,449.42
CS0062 ZR72KCE-TFD Fig 3 6.0 7720 9610 11750 14160 16890 18425 17.06 39 1,407.60
CS0064 ZR81KCE-TFD Fig 3 6.5 84100 10530 13040 15890 19060 20775 18.75 39 1,570.80
CS0065 ZR94KCE-TFD Fig 4 8.0 9130 11480 14060 17000 20410 22395 22.12 57 2,089.98
CS0067 ZR108KCE-TFD Fig 4 9.0 11200 14080 17320 20970 25130 27505 24.87 60 2,363.34
CS0069 ZR125KCE-TFD Fig 4 10.0 12980 16320 20070 24300 29130 31880 29.08 61 2,472.48
CS0071 ZR144KCE-TFD Fig 4 12.0 14770 19020 23680 28890 34780 37630 33.20 61 2,724.42
R404a Medium TempRealcoldStock No.
Model Fig Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
Weight (Kg)
System Price$ Excl. GST
R404a
-15°C -10°C -5°C 0°C +5°C +7.2°C
Air Conditioning - 380/420 Volt 50 Hz Three Phase - R410a*
CS0220 ZP235KCE-TWD-522
Fig 5 20.0 25100 31300 38400 46600 53350 60100 36.30 140 7,491.90
CS0230 ZP385KCE-TWD-522
Fig 5 30.0 41600 51400 62800 76000 86850 97700 66.70 176 10,416.24
* A full range of R410a Scroll Compressors is available on indent
R404a Low TempRealcoldStock No.
Model Fig Nom. Hp
Capacity (w) @ 45° Condensing Temp Displ. (m3/hr)
System Price$ Excl. GST
R404a
-25°C -20°C -15°C -10°C -5°C 0°C +7.2°C
Refrigeration 380/420 Volt 50 Hz Three Phase
CS0017 ZF18K4E-TFD Fig 6 6.0 5.14 6.39 7.89 9.66 11.75 14.15 18.25 17.06 3,430.26
CS0020 ZF24K4E-TWD Fig 7 7.5 6.37 7.89 9.69 11.80 14.35 17.35 22.40 20.86 4,369.68
CS0024 ZF33K4E-TWD Fig 7 10.0 8.75 10.90 13.45 16.50 20.10 24.30 31.30 28.78 4,916.40
CS0028 ZF40K4E-TWD Fig 8 13.0 10.85 13.45 16.55 20.20 24.60 29.70 38.30 35.55 5,435.58
CS0032 ZF48K4E-TWD Fig 8 15.0 13.10 16.35 20.20 24.80 30.10 36.20 46.30 42.76 5,962.92
CS0118 ZB30KCE-TFD Fig 9 4.0 3.19 4.07 5.12 6.37 7.84 9.56 13.85 11.68 1,801.32
CS0120 ZB38KCE-TFD Fig 9 5.0 4.01 5.09 6.38 7.91 9.72 11.85 15.40 14.37 1,875.78
CS0122 ZB45KCE-TFD Fig 9 6.0 4.73 6.00 7.51 9.31 11.45 13.90 18.05 17.06 2,011.44
CS0126 ZB58KQE-TFD Fig 10 8.0 5.25 7.42 9.75 12.35 15.25 18.60 24.10 22.12 2,485.74
CS0130 ZB76KQE-TFD Fig 11 10.0 8.12 10.55 13.35 16.55 20.30 24.70 31.90 28.82 2,653.02
CS0136 ZB92KCE-TWD Fig 1 13.0 9.00 12.30 16.00 20.10 24.90 30.30 39.10 35.55 5,502.90
CS0138 ZB11MCE-TWD Fig 1 15.0 12.45 15.50 19.15 23.40 28.40 34.20 43.50 42.76 6,112.86
Note: Duty ratings based on 45°C condensing temp & 2K sub-cooling.
CC77
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - COPELAND SCROLL™
Copeland Scroll™ Compressors AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
CCS1000 Start Capacitor ZR68 52.02
CCS1001 Start Capacitor ZR28 - 47 22.08
CCS1002 Run Capacitor ZR68 33.66
CCS1003 Run Capacitor ZR28 22.59
CCS1004 Run Capacitor ZR42 - 47 38.91
CCS1005 Run Capacitor ZR36 24.17
CCS1006 C/Case Heater ZR84 -144, ZB58-76 46.77
CCS1007 C/Case Heater ZR22 - 81, ZB30-45 32.08
CCS1008 Crankcase Heater ZR16 - 19M 32.08
CCS1009 Suction Rotalock Seal 1.12
CCS1010 Suction Rotalock Seal 4.85
CCS1011 Potential Relay ZR68 110.16
CCS1012 Current Relay ZF 171.36
CCS1013 Potential Relay ZR28 - 42 35.75
CCS1014 Summit Temp T/Stat 23.66
CCS1017 Valve Kit ZB58 194.82
CCS1018 Valve Kit ZF18 126.48
CCS1019 Valve Kit ZF24 183.60
CCS1020 Valve Kit ZF33 - 40, ZB92 173.40
CCS1021 Valve Kit ZF48, ZB11 216.24
CCS1023 CC Heater ZF40 - 48, ZB92 39.42
CCS1024 Crankcase Heater ZP385 82.52
CCS1025 Crankcase Heater ZP235 79.36
Figure One Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) H (mm)
ZB92KCE 492 209 176 306 55 88 551
ZB11MCE 533 209 176 306 55 88 596
Note: Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Figure One
CC78
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - COPELAND SCROLL™
Figure Two Dimensions Model H (mm) D (mm) S (mm)
ZR28K3E 383 357 264
ZR36K3E 406 380 283.5
ZR42K3E 419 393.8 296.3
Figure Three Dimensions Model H (mm) D (mm) S (mm)
ZR47K3E 436
ZR61KCE 476 429 316
ZR68KCE 476 429 316
ZR72KCE 476 429 316
ZR81KCE 462 433 316
Figure Two Figure Three
Figure Four Dimensions Model H (mm) D (mm) S (mm)
ZR94KCE 495 463 113
ZR108KCE 552 520 141
ZR125KCE 552 520 141
ZR144KCE 552 520 141
Figure Five Dimensions Model H (mm) D (mm) S (mm)
ZP235KCE 713 685 352
ZP385KCE 716 678 394
Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Figure Four Figure Five
Air Conditioning
CC79
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - COPELAND SCROLL™
Figure Eight Figure Nine
Figure Six Figure Seven
Figure Ten Figure Eleven
Figure Six Dimensions Model A +/- 3 (mm) C +/- 3 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)
ZF18K4E 410 233 297 48 81 341 489
Figure Seven Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)
ZF24K4E 496 209 176 306 55 88 359 561
ZF33K4E 496 209 176 306 55 88 359 561
Figure Eight Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) G (mm) H (mm)
ZF40K4E 504 209 176 306 55 88 366 569
ZF48K4E 533 209 176 306 55 88 366 598
Figure Nine Dimensions Model A +/- 3 (mm) C (mm) C1 (mm) D (mm) E (mm) F (mm) H (mm)
ZB30KCE 410 233 - 297 48 81 457
ZB38KCE 410 233 - 297 48 81 457
ZB45KCE 410 233 - 297 48 81 457
Figure Ten Dimensions Model H (mm) W (mm) L (mm)
ZB58KQE 477 284.2 263.6
Figure Eleven Dimensions Model H (mm) W (mm) L (mm)
ZB76KQE 546.1 284.2 263.6
Specified compressor heights are indicative of series dimensions. Certain model heights vary from specification. Please consult Realcold if the compressor height is crucial.
Refrigeration
CC80
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI SEALED RECIPROCATING
Frascold Semi Sealed Compressors - IntroductionFrascold History:
The Fraschini Company was founded in 1936 to produce open drive compressors. Renamed Frascold in 1965, the company continued to develop its range of open drive compressors, adding a semi-hermetic reciprocating range by 1975. Since 1987 the factor production line has been continually upgraded with computer controlled machining processes, and this has enabled Frascold to increase production and maintain very high manufacturing standards. Quality control procedures conform to EN ISO 9001 standard.
Frascold’s initiative and technology has led to the development of its low clearance high capacity design, where the piston head is shaped to suit the suction valve reed profile. This results in very low clearance, which is a major factor in improving performance and efficiency in respect to standard compressors.
The process of continual improvements has made Frascold a world leader as a manufacturer and supplier of semi-hermetic compressors throughout the world. Its modern, high performance range of semi-hermetic compressors is suitable for Refrigeration and Air Conditioning applications. Ranging from 3.93 cubic metres per hour through to 205.80 cubic metres per hour and with refrigeration capacities from 200 watts through to 280,000 watts, Frascold’s semi-hermetic compressors are able to run on a large range of modern refrigerants.
Notes on the Frascold Range
Please note that the superheat of the suction vapour entering the compressor must not exceed the values stated by the manufac-turer. Failure to adhere to this will void any warranty or performance claims.
Frascold offers a range of CO2 compressors, suitable for sub-critical system from 1.5HP to 9HP and trans-critical 10HP to 25HP.
Evaporating Range - Guideline Only
All compressors are suction vapour cooled. Refer to Compressor Data Book for individual operating ranges.
H +10°C/0°C M 0°C/-15°C L -15°C/-30°C
See Warranty section at the front of catalogue for Warranty details
Single Phase: Protection with thermal Klixon.
Three Phase: Inherent protection, thermistor with control relay.
All Frascold compressors are charged with Polyolester oils. Please refer to our Technical Department for refrigerant blend applications.
Our Technical Department is only too happy to select equipment and provide quotations for all your requirements. Refer to Spares Section at the rear of this catalogue, for Frascold Compressor Spares.
CC81
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI SEALED RECIPROCATING
Frascold Semi Sealed - Medium/ Low TempColumn Key: FIG = Picture #, D = Displacement, W = Weight for all models listed
RealcoldStock No.
Model Hp/kW Nom.
Disp. m3/hr
Oil ChargeLitres
Nominal Capacity (Kw) System Price$ Excl. GST
R404a R134a
-5.00 -25.00 -5.00
Single Phase 220/240 Volt 50 Hz
C5016 A16 1.0 5.47 1.25 3.30 1.40 1.60 2,176.68
C5033 A157 1.5 6.91 1.25 4.20 1.70 2.00 2,178.72
C5038 B159 1.5 8.96 1.25 5.30 2.20 2.60 2,244.00
Three Phase 380/415 Volt 50 Hz
C5031 A157 1.5 6.91 1.25 4.20 1.65 2.60 2,175.66
C5036 B159 1.5 8.96 1.25 5.30 2.00 3.40 1,864.56
C5046 B210 2.0 9.84 1.25 5.90 2.30 3.70 2,175.66
C5051 D213 2.0 13.84 1.5 - 3.20 5.00 2,762.16
C5061 D313 3.0 13.84 1.5 8.20 3.10 4.90 2,921.28
C5071 D318 3.0 17.93 1.5 - 4.50 6.90 2,911.08
C5078 D418 4.0 17.93 1.2 11.20 4.60 7.20 2,909.04
C5086 F424 4.0 23.6 2.6 14.70 5.80 9.10 3,374.16
C5095 F524 5.0 23.6 2.6 14.50 5.50 8.90 3,211.98
C5096 Q528Y 5.0 27.88 1.8 - 6.70 10.20 3,942.30
C5097 Q533Y 5.0 32.66 1.8 - 8.10 11.90 4,266.66
C5098 Q728 7.5 27.31 2.6 17.70 6.90 10.20 4,195.26
C5124 S733 7.5 32.8 3.3 20.70 8.30 12.80 5,203.02
C5127 S739 7.5 38.25 3.3 24.60 10.20 15.30 5,365.20
C5129 S1039 10.0 38.25 3.3 24.60 10.20 15.20 5,508.00
C5133 S1051 10.0 50.43 3.3 - 13.20 19.50 5,973.12
C5137 S1551 15.0 50.43 3.3 31.70 12.70 19.30 5,200.98
C5155 V1559 15.0 58.48 4.25 37.30 15.20 23.30 6,701.40
C5160 V1571 15.0 70.77 4.25 - 17.90 27.60 7,723.44
C5165 V2059 20.0 58.84 4.25 36.80 13.50 23.40 7,138.98
C5172 V2084 20.0 83.81 4.25 - 20.20 30.40 8,746.50
C5185 V2571 25.0 70.77 4.25 44.20 16.50 26.60 8,892.36
C5190 Z25106 25.0 106.16 5 67.90 25.70 37.80 11,516.82
C5192 V3084 30.0 83.81 4.25 53.30 20.20 30.50 9,754.26
C5198 Z30126 30.0 125.72 7.5 - 29.80 46.50 12,377.70
C5200 Z35106 35.0 106.16 5 67.50 25.80 40.90 11,503.56
C5206 Z40126 40.0 125.72 7.5 79.00 29.50 48.20 12,816.30
C5210 Z40154 40.0 154.38 7.5 - 40.00 56.20 14,991.96
C5215 Z50154 50.0 154.38 7.5 96.30 36.20 57.50 16,014.00
C5233 W50187 50.0 186.1 8 - 42.90 68.60 18,202.92
C5234 W60187 60.0 186.1 8 119.70 44.90 69.80 18,933.24
C5235 W60206 60.0 205.8 8 131.20 49.60 78.80 19,904.28
C5238 W70206 70.0 205.8 8 131.00 49.50 77.60 20,247.00
Note: Frascold offers a range of: i) R410a semi-hermetic compressors from 7.5 HP to 15 HP ii) CO² sub-critical Semi-hermetic compressors from 1.5 HP to 10 HP iii) CO² trans-critical semi-hermetic compressors from 10 HP to 25 HP
Visit www.frascold.com for additional product information.
Realcold offer equipment selection services. Please feel free to use this service. Refer to spares section at rear for Frascold compressor spares.
A
V
D
F
S
Z
W
B
CC82
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI SEALED RECIPROCATING
Capacity ControlRealcoldStock No.
Description System Price$ Excl. GST
C5221 To suit "T" & "S" Series (Mk II) 1 cylinder head c/w solenoid 50% control 402.90
C5225 To suit “Z” & “V” & “W” Series 1 head only.
1 head for “V”=50% control. 1 head for “Z” = 33% control
2 heads for “Z”=33% & 66% control (Z:33%+66% = 2 x C5225)
2 heads for “W”=50% & 75% control (W:50%+75% = 2 x C5225)
430.44
AccessoriesRealcoldStock No.
Description Wattage Incl. Installation System Price$ Excl. GST
R0316 Rubber Mounts 40 x 40 mm 2 - 3 HP 35.75
R0552 Crankcase Heater F, S, T Series 70 Watt Fitted 160.14
R0553 Crankcase Heater A, B, D Series 50 Watt Fitted 160.14
R0555 Crankcase Heater (to suit V, W, Z Series) MK 2 150 Watt Fitted 238.68
C5805 Head Cooling Fan (to suit A, B, D, F Series) Fitted 514.08
C5808 Head Cooling Fan (to suit S, T, V, Z Series) Fitted 532.44
R0824 Delta-P Oil Differential Pressure Switch suits V, Z and W Series.
The Delta-P is easy and fast to mount, with no mounting bracket required. The electric component can be removed without refrigerant leakage. Includes a reset push button.
536.52
Higher efficiency with Low Clearance High Capacity (LCH)
LCH design, distinguished the piston-valve plate assembly, is the final result of a close research in order to reduce clearance, the most important reason of loss of computer efficiency. To considerably restrict such efficiency loss, FRASCOLD has shaped the head of the piston so that it matches suction valve reed profile.
In the compressor with LCH design, contoured piston lower cylinder clearance and an increase in capacity and efficiency it results respect to the performance of a standard compressor.
Note: For Frascold Lubricants please refer to page CL114.
CC83
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI-HERMETIC SCREW
Semi-Hermetic Screw Compressor - IntroductionFrascold started manufacturing a range of twin screw compressors in 1995.
The twin screw compressor range comprises twenty four models across three ranges.
C-TSH Range: This range of compact twin screw compressors comprises eight models from a nominal 40HP to 120HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The C-TSH range is suited to applications in the operating temperature range from +12.5°C to -15°C on R22/ R407c/ R134a/ R404a. Compressors are fitted with integral oil separator / reservoir.
C-XH0 Range: This range of compact twin screw compressors comprises twenty seven models from a nominal 50HP to 300HP, with displacements from 199 to 912 cubic metres per hour at 50Hz. The C-XH0 range is suited to applications in the operating temperature range from +12.5°C to -15°C on R407c/R134a; +0°C to -25°C on R404a/R507. Compressors are fitted with integral oil separator / reservoir.
R-TSH Range: This range comprises eight models from nominal 40HP to 120HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The R-TSH range is suited to air conditioning and medium/ high temperature applications, in the temperature operating range from + 7. °5C to - 20°C on R404a/R507A; +12.5°C to -20°C on R22; +20°C to -10°C on R134a.
R-TSL Range: This range comprises eight models from nominal 30HP to 100HP, with displacements from 120 to 360 cubic metres per hour at 50Hz. The R-TSL range is suited to low temperature applications, in the temperature operating range from -20°C to -45°C on R404a/R507A
Outstanding Features Screw Profiles: The compressors are two-shaft rotary displacement design, with innovative profiles of the screws. (Ratio 5:6 between male & female screw). The shafts are fitted with large roller bearings sized to bear both radial and axial loads, resulting in reduction of friction, vibration and lower noise levels. Discharge check valve, located in the service valve prevents counter rotation when compressor stops operating.
Electric Motor: High efficiency electric motor is two-pole, three phase asynchronous type. The rotor is fitted to the shaft of the male screw. Cooling of the motor is carried out by the suction gas flowing through slots in the rotor, also causing any liquid refrigerant to be separated due to the centrifugal action.
Power Supply: 400/3/50
Connection: Part Winding Start (PWS) 50% + 50% current distribution
Capacity Control: All compressors are fitted with capacity control, which operates by means of a three-way solenoid valve, directing the flow of oil under pressure, to a slide piston mechanism. At full load, oil under pressure pushes against the piston, opposing the spring and closing the capacity control device. At reduced load conditions, the oil is diverted to the suction side of the compressor, and the spring forces the piston to open the capacity control device, which reduces the displacement and consequently reduces the capacity of the compressor.
E-Protection Device: All screw compressors are equipped with electronic protection called KRIWAN NT 68 FRY, complete with thermistor sensors, performing the following functions:
• Controlofmaximumtemperatureoftheelectricmotor+120°C,throughsixPTCthermistors,fittedtothestatorwinding.
• Controlofthemaximumdischargetemperature+120°CthroughPTCsensorplacedoncompressordischargeside.
• Controlofrotationdirectionoftheelectricmotorandphasesequence.
• Protectionofphaseandvoltagefailures.
• ControlofbreakageandshortcircuitinchainofPTCsensors.
Screw compressors can be installed in parallel configurations and the R series are well suited to two-stage systems.
Capacity Control StepsModel Number % of full capacity - Steps
R-TSH8 40 120Y; R-TSL8 30 120Y 100 - 50; one stage capacity control
R-TSH8 50 150Y; R-TSL8 40 150Y 100 - 50; one stage capacity control
R-TSH8 60 186Y; R-TSL8 50 186 Y 100 - 50; one stage capacity control
R-TSH8 70 210Y; R-TSL8 60 210Y 100 - 50; one stage capacity control
R-TSH8 80 240Y; R-TSL8 70 240Y 100 - 75 - 50; two stage capacity control
R-TSH8 90 270Y; R-TSL8 80 270Y 100 - 75 - 50; two stage capacity control
R-TSH8 100 300Y; R-TSL8 90 300Y 100 - 75 - 50; two stage capacity control
R-TSH8 120 360Y; R-TSL8 100 360Y 100 - 75 - 50; two stage capacity control
CC84
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI-HERMETIC SCREW
Compact Twin Screw Compressor - Medium TemperatureRealcoldStock No.
Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST
C5251 C-TSH8 40 120Y MBP-HBP 40/30 120 18,949.56
C5252 C-TSH8 50 150Y MBP-HBP 50/37 150 19,612.56
C5253 C-TSH8 60 186Y MBP-HBP 60/45 186 21,560.76
C5254 C-TSH8 70 210Y MBP-HBP 70/52 210 22,204.38
C5255 C-TSH8 80 240Y MBP-HBP 80/60 240 24,834.96
C5256 C-TSH8 90 270Y MBP-HBP 90/67 270 26,122.20
C5257 C-TSH8 100 300Y MBP-HBP 100/75 300 28,753.80
C5258 C-TSH8 120 360Y MBP-HBP 120/90 360 30,040.02
Note: These Compressors are available as indent stock only
CXHO Compact Twin Screw CompressorsRealcoldStock No.
Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST
R134a
CFS0020 CXH0 50 199Y CXH0 50/37 199 17,124.78
CFS0022 CXH0 60 230Y CXH0 60/45 230 17,839.80
CFS0024 CXH0 70 264Y CXH0 70/52 264 20,529.54
CFS0026 CXH0 80 298Y CXH0 80/60 298 21,243.54
CFS0028 CXH0 90 340Y CXH0 90/67 340 22,230.90
CFS0030 CXH0 100 370Y CXH0 100/75 370 27,610.38
CFS0034 CXH0 110 398Y CXH0 110/81.5 398 29,879.88
CFS0036 CXH0 125 468 CXH0 125/93.8 468 30,720.36
CFS0038 CXH0 140 538Y CXH0 140/104 538 31,854.60
CFS0042 CXH0 160 620Y CXH0 160/118.8 620 40,343.04
CFS0044 CXH0 180 702Y CXH0 180/133.7 702 44,440.38
CFS0046 CXH0 210 810Y CXH0 210/156 810 48,138.90
CFS0048 CXH0 240 912Y CXH0 240/178.3 912 50,261.52
R407c & R404a
CFS0060 CXH0 70 199Y CXH0 70/52 199 18,133.56
CFS0062 CXH0 80 230Y CXH0 80/60 230 19,120.92
CFS0064 CXH0 90 264Y CXH0 90/67 264 21,663.78
CFS0066 CXH0 100 298Y CXH0 100/75 298 23,366.16
CFS0068 CXH0 120 340Y CXH0 120/88 340 24,773.76
CFS0072 CXH0 110 316Y CXH0 110/81.5 316 27,190.14
CFS0074 CXH0 125 372Y CXH0 125/93.8 372 28,324.38
CFS0076 CXH0 140 428Y CXH0 140/104 428 30,720.36
CFS0078 CXH0 160 468Y CXH0 160/120 468 32,568.60
CFS0082 CXH0 180 545Y CXH0 180/133.7 545 41,204.94
CFS0084 CXH0 210 620Y CXH0 210/156 620 48,265.38
CFS0086 CXH0 240 702Y CXH0 240/178.3 702 49,252.74
CFS0088 CXH0 280 810Y CXH0 280/208 810 52,089.36
CFS0090 CXH0 300 912Y CXH0 300/222.9 912 54,631.20
Note: that these Compressors are available as Indent stock only
CC85
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI-HERMETIC SCREW
Standard equipment - MBP-HBP
Screw compressor is supplied complete with:
• oil separator directly assembled with flange to the compressor body
• oil demister inside the separator
• oil strainer
• discharge connection complete with valve and check valve
• suction valve
• internal relief valve
• capacity control device
• electronic protection device
• electric box with IP65 protection
• oil heater
• vibration absorbers
Standard equipment - CXH0
• Discharge valve & integrated check valve
• Suction flange with solder busching
• Integrated pressure relief valve
• Capacity control (step or step less)
• Motor with ptc-temperature sensors
• Electronic control unit (temperature and phase sequence monitoring auto reset)
• Terminal box enclosure class IP65
• Oil service valve, oil filter, sight glass & oil charge
• Start unloading
• Discharge temperature sensor
• Protective charge
Twin Screw Compressors - Medium TemperatureRealcoldStock No.
Model Description Hp/kW Nom. Disp. m3/hr System Price$ Excl. GST
C5261 R-TSH8 40 120Y MBP 40/30 120 17,641.92
C5262 R-TSH8 50 150Y MBP 50/37 150 18,304.92
C5263 R-TSH8 60 186Y MBP 60/45 186 20,254.14
C5264 R-TSH8 70 210Y MBP 70/52 210 20,897.76
C5265 R-TSH8 80 240Y MBP 80/60 240 23,529.36
C5266 R-TSH8 90 270Y MBP 90/67 270 24,834.96
C5267 R-TSH8 100 300Y MBP 100/75 300 27,448.20
C5268 R-TSH8 120 360Y MBP 120/90 360 28,753.80
Twin Screen Compressor - Low Temperature
C5271 R-TSL8 30 120Y LBP 30/22 120 16,978.92
C5272 R-TSL8 40 150Y LBP 40/30 150 17,641.92
C5273 R-TSL8 50 186Y LBP 50/37 186 19,201.50
C5274 R-TSL8 60 210Y LBP 60/45 210 19,864.50
C5275 R-TSL8 70 240Y LBP 70/52 240 22,204.38
C5276 R-TSL8 80 270Y LBP 80/60 270 23,529.36
C5277 R-TSL8 90 300Y LBP 90/67 300 26,122.20
C5278 R-TSL8 100 360Y LBP 100/75 360 27,448.20
Note: These Compressors are available as indent stock only
Standard equipment - MBP-LBP
Standard equipment mounted on the compressor
• capacity control device
• integral electronic protection, includes:
o sensor for maximum discharge temperature
o sensor for maximum temperature of electric motor
o electronic module
• suction valve
• discharge valve with check valve
Standard equipment supplied loose with compressor
• vibration absorbers
• components for external oil piping, includes:
o oil strainer with core
o solenoid valve with coil and plug
o oil flow switch
o electronic module for oil flow switch
o oil sight glass
CC86
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI-HERMETIC SCREW
Semi-Hermetic Screw Compressor - AccessoriesRealcoldStock No.
Model Description System Price$ Excl. GST
C5820 TOOWK150 Visual Indicator POA
C5822 TOOWK151 Visual Indicator POA
C5824 SZ-WOC1 Water Cooled Oil Cooler POA
C5826 SZ-WOC2 Water Cooled Oil Cooler POA
C5828 SZ-WOC3 Water Cooled Oil Cooler POA
C5830 SZ-AOC1 Air Cooled Oil Cooler POA
C5832 SZ-AOC2 Air Cooled Oil Cooler POA
C5834 SZ-AOC3 Air Cooled Oil Cooler POA
C5836 TOOWK200 Remote Oil Separator POA
C5838 TOOWK201 Remote Oil Separator POA
C5840 TOOWK202 Remote Oil Separator POA
C5844 TOOWK301 Economizer R404a POA
C5848 TOOWK303 Economizer R404a POA
C5852 TOOWK305 Economizer R404a POA
C5856 TOOWK307 Economizer R404a POA
C5858 TOOWK400 Liquid Injection Valve POA
C5860 SZ-OIL1 FC300 19 Litre Oil (M/T R404) POA
C5862 SZ-OIL3 FC170 19 Litre Oil (L/T R404a) POA
C5864 SZ-OIL2 FC170 25 Litre Oil (L/T, M/T R22) POA
C5866 T00WK110 Oil Filter Kit POA
Oil Separator
Sub CoolerAir Cooled Air Cooler
Diagram Legend:
Oil Separator Sub Cooler
1 = Refrigerant Outlet F1 = Economiser Outlet
2 = Service Valve Connection F2 = Liquid Inlet for Sub Cooling
3 = Refrigerant Inlet F3 = Refrigerant Inlet for TEV
4 = Connection for Oil Charge Valve F4 = Liquid Outlet - Subcooled Liquid
5 = Oil Level Sight Glass
6 = Parallel Compressors Oil Outlet
7 = Oil Level Control
8 = Oil Outlet
9 = Oil Heater
10 = Safety Valve Connection
11 = Thermostat Sensor
CC87
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSORS - SEMI-HERMETIC SCREW
Semi-Hermetic Screw Compressor - AccessoriesCompressor Model
R-TS
H1
40 1
20 Y
R-TS
H1
50 1
50 Y
R-TS
H1
60 1
86 Y
R-TS
H1
70 2
10 Y
R-TS
H1
80 2
40 Y
R-TS
H1
90 2
70 Y
R-TS
H1
100
300
Y
R-TS
H1
120
360
Y
R-TS
L1 3
0 12
0 Y
R-TS
L1 4
0 15
0 Y
R-TS
L1 5
0 18
6 Y
R-TS
L1 6
0 21
0 Y
R-TS
L1 7
0 24
0 Y
R-TS
L1 8
0 27
0 Y
R-RS
L1 9
0 30
0 Y
R-TS
L1 1
00 3
60 Y
remote oil separator
TOOWK200 • • • • • • • • • •
TOOWK201 • • • • • •
TOOWK202
visual indicator for oil strainer clogging
TOOWK150 • • • • • • • • • • • • • • • •
electric indicator for oil strainer clogging
TOOWK151 • • • • • • • • • • • • • • • •
water cooled oil cooler
SZ-WOC1 • • • • • • • • • • • •
SZ-WOC2 • • • •
SZ-WOC3
air cooled oil cooler
SZ-AOC1 • • • • • • • • • • • •
SZ-AOC2 • • • •
SZ-AOC3
economizer kit for R22
TOOWK300 • •
TOOWK302 • •
TOOWK304 • •
TOOWK306 • •
economizer kit for R404a-R507A
TOOWK301 • •
TOOWK303 • •
TOOWK305 • •
TOOWK307 • •
lubricant for R22 (19I can)
SZ-OIL2 (FCH) • • • • • • • • • • • • • • • •
lubricant R404a, 50W7A, R143A (19I can)
SZ-OIL3 (FCL) • • • • • • • • • • • • • • • •
CD88
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DEFROST CONTROLS
Defrost ControlsRealcoldStock No.
Model Description System Price$ Excl. GST
G0090 PARAGON
8145-21
(Replaces Precision 6145-21)
• Time initiated.
• Externally temperature or pressure terminated.
• 1 - 6 defrosts per 24 hours.
• Minimum of 4 hours between defrost.
• Length of defrost 4 to 110 minutes in 2 minute increments.
• Has relay contact facility.
• Suitable for 208 - 240 V 50 Hz.
• Maximum contact rating is 25 Amps.
296.20
G0091 PARAGON
632-21*
• Time initiated, time terminated with fan delay.
• 1 - 8 defrost per 24 hours.
• Minimum of 3 hours between defrosts.
• Pre-defrost delay 0 to 30 minutes in 3 minute increments.
• Defrost period 3 to 45 minutes in 3 minute increments.
• Post defrost delay 3 to 15 minutes in 3 minute increments.
• Suitable for 208 - 240 V 50 Hz.
• Maximum contact rating is 10 Amps.
539.90
G0092 PARAGON
8045-21
(Replaces Precision 6045-21)
• Time initiated, time terminated.
• 1 - 6 defrosts per 24 hours.
• Minimum of 4 hours between defrosts.
• Length of defrost 4 - 110 minutes in 2 minute increments.
• For basic defrost systems.
• Suitable for 220 - 240 V 50 Hz.
• Maximum contact rating is 25 Amps.
275.88
G0093 PARAGON
8245-21
(Replaces Precision 6245-21)
• Time initiated, pressure terminated.
• 1 - 6 defrosts per 24 hours.
• Minimum of 4 hours between defrosts.
• Length of defrost 4 to 110 minutes in 2 minute increments.
• Adjustable cut-in setting dial calibrated from 36-110 psi
• (248 - 758 kPa) for R12, R22, R502.
• Suitable for 208 - 240 V 50 Hz.
• Maximum contact rating is 40 Amps.
595.00
G0084 FRIGO FLASH
16022*
• Compact Series 72 mm x 72 mm
• 24 hour clock
• Supply voltage 220 / 240 V +10% - 15% 50 / 60 Hz
• Operating Temperature: -10°C/ +50°C
• 10 minute programming segments
• 72 switchings per day
• Minimum interval between 2 switchings: 20 minutes
• Contact ratings: 16 Amp resistive, 3 Amp inductive
132.80
G0086 FRIGO FLASH
11721*
• 72 mm x 102.5 mm
• 24 hour clock
• Supply voltage 220 V +10% - 15% 50 Hz
• Operating Temperature: -10°C/ +50°C
• Up to 12 defrosts per day
• Defrosting can be started every 2 hours
• Defrost duration 5 - 110 minutes
• Contact ratings: 10 Amp resistive, 2 Amp inductive
172.43
* NB: External relay may be required in some applications.
CD89
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DEFROST CONTROLS & ACCESSORIES
Defrost Safety ThermostatsRealcoldStock No.
Model Description System Price$ Excl. GST
G0014 ML55 Thermostat 10 Amps Open +13°C Close +2°C 12.09
G0016 ML70 Thermostat 10 Amps Open +21°C Close +10°C 12.09
W7520 - Thermal Overload (Defrost Klixon) 25 Amp 74.10
G0020 GL243 Surface Mount Clip (3 per Pack) 9.08
G0022 GL249 Tube Mount Clip 3/8 - 1/2 - 5/8 (2 per Pack) 18.41
Defrost Heat TapeRealcoldStock No.
Model Description System Price$ Excl. GST
N0626 FST25Jimi Heat Self Regulating Tape 26W/M at 10°C - 240 VAC
Minimum installation temperature -40°C
32.13
N0635 Seal Kit FCT BTV-2 30.00
N0616 and N0626 can be used in evaporator drains, provided correct termination kits are fitted.
Condensate PansThe MA-Line condensate evaporator pan eliminates floor drains. The unit is made of die-cast aluminium and the resulting hard, bright surface give the pan unequalled efficiency and trouble free operation. The pan is self standing. All terminal connections are covered with moisture proof rubber. Evaporation rate is 250ml per hour at 22.2°C room temperature. The unit’s heating element is sealed in ¼” Bundy weld tubing.
RealcoldStock No.
Description Voltage Watts Dimensions (mm) System Price$ Excl. GST
L W H
C4080 MA-Line Condensate Pan - Small 240V 160 260 103 60 234.60
C4082 MA-Line Condensate Pan - Large 240V 160 260 121 75 234.60
N0616 and N0626 can be used in evaporator drains, provided correct termination kits are fitted.
CD90
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DRIERS
Sporlan Driers - FlareRealcoldStock No.
Brand Model Size Cu In System Price$ Excl. GST
Liquid Line Driers - Sporlan
SP3001 Sporlan CATCH-ALL 032 1/4" MF 3 23.18
SP3002 Sporlan CATCH-ALL 052 1/4" MF 5 30.90
SP3003 Sporlan CATCH-ALL 082 1/4" MF 8 37.00
SP3004 Sporlan CATCH-ALL 162 1/4" MF 16 45.79
SP3008 Sporlan CATCH-ALL 053 3/8" MF 5 30.90
SP3009 Sporlan CATCH-ALL 083 3/8" MF 8 37.00
SP3011 Sporlan CATCH-ALL C163 3/8" MF 16 45.79
SP3012 Sporlan CATCH-ALL 303 3/8" MF 30 88.25
SP3015 Sporlan CATCH-ALL 084 1/2” MF 8 37.54
SP3017 Sporlan CATCH-ALL 164 1/2" MF 16 50.23
SP3018 Sporlan CATCH-ALL 304 1/2" MF 30 88.25
SP3022 Sporlan CATCH-ALL 165 5/8" MF 16 52.43
SP3023 Sporlan CATCH-ALL 305 5/8" MF 30 88.25
Sporlan Driers - SweatRealcoldStock No.
Brand Model Size Cu In System Price$ Excl. GST
Liquid Line Driers - Sporlan
SP3071 Sporlan CATCH-ALL 032S 1/4" SWEAT 3 22.08
SP3072 Sporlan CATCH-ALL 052S 1/4" SWEAT 5 29.43
SP3073 Sporlan CATCH-ALL C082S 1/4" SWEAT 9 35.24
SP3078 Sporlan CATCH-ALL C053S 3/8" SWEAT 5 29.43
SP3079 Sporlan CATCH-ALL C083S 3/8" SWEAT 9 35.24
SP3081 Sporlan CATCH-ALL C163S 3/8" SWEAT 16 43.61
SP3085 Sporlan CATCH-ALL C084S 1/2" SWEAT 9 35.75
SP3087 Sporlan CATCH-ALL C164S 1/2" SWEAT 16 47.84
SP3092 Sporlan CATCH-ALL C165S 5/8" SWEAT 16 49.93
Heldon Driers - FlareRealcoldStock No.
Brand Model Size Cu In System Price$ Excl. GST
Liquid Line Driers - Heldon
H0125 Heldon FL 306 3/4" MF 30 108.12
Mueller Driers - SweatRealcoldStock No.
Brand Model Size Cu In System Price$ Excl. GST
Liquid Line Driers - Mueller
H0130 Mueller SD 417 7/8" SWEAT 41 96.90
CD91
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DRIERS
SF Suction Line FiltersThe Sporlan SF Suction Line Filter protects the compressor from dirt. It is designed with an optional relief feature that opens if the filter plugs. It also has a full flow design for low pressure drop. It is suitable for use with all brazing alloys and maximum corrosion resistance.
RealcoldStock No.
Description System Price$ Excl. GST
SP3155 Sporlan Suction Filter SF-285-T 5/8" 101.75
SP3156 Sporlan Suction Filter SF-286-T 3/4" 112.46
SP3157 Sporlan Suction Filter SF-287-T 7/8" 102.82
SP3159 Sporlan Suction Filter SF-289-T 1.1/8" 109.24
SP3161 Sporlan Suction Filter SF-4811-T 1.3/8" 155.30
SP3163 Sporlan Suction Filter SF-4813-T 1.5/8" 166.01
Suction Line Filter DriersThe Suction Line Filter Drier has been specifically designed for system clean-up after a burn out or any time system cleanliness is questionable. High acid and water absorption. For use with HCFCs, HFCs, and lubricants that go with them. Not recommended for permanent use. Once the suction line filter drier has completed its clean-up procedure it should be replaced with a suction line filter.
RealcoldStock No.
Model Description Filter Area Sq. In. Volume Cu. In. System Price$ Excl. GST
Burn-Out Driers
H0305 Virginia WSL-163S 3/8” SW 24 15 37.49
H0306 Mueller A17224 1/2" SW 26 16 37.49
H0308 Mueller A17227 5/8" SW 26 16 32.12
H0311 Micro Guard FDF 264T 1/2" MF 26 16 41.93
H0312 Micro Guard FDF 265T 5/8" MF 26 16 44.12
H0313 Micro Guard FDS 166TT 3/4" SW 26 16 44.72
H0314 Micro Guard FDS 267T 7/8" SW 26 16 44.72
H0315 Micro Guard FDS 269T 1.1/8" SW 26 16 51.89
H0316 Micro Guard FDS 529T 1.1/8" SW 52 30 66.78
Reversible Heat Pump Driers
RealcoldStock No.
Sporlan Code Description System Price$ Excl. GST
SP3240 HPC-103 Heat Pump Drier 3/8” MF 65.66
SP3241 HPC-104 Heat Pump Drier 1/2” MF 67.32
SP3250 HPC-103S Heat Pump Drier 3/8” OD 65.66
SP3251 HPC-104S Heat Pump Drier 1/2” OD 67.32
SP3261 HPC-165SHH Heat Pump Drier 5/8" OD 109.78
Suction Line
CD92
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DRIERS
Refillable Shells - Liquid LineRealcoldStock No.
Model Size Core Max. RatingkW Med Temp
Max. Rating kW Low Temp
System Price$ Excl. GST
Refillable Shells - Liquid Line - Carly
H0135 Carly BCY 485S 5/8" ODS 1 Core 36.0 26.7 246.84
H0139 Carly BCY 487S 7/8" ODS 1 Core 52.2 34.8 238.68
H0140 Carly BCY 967S 7/8" ODS 2 Core 87 52.2 274.38
H0138 Carly BCY 489S 1.1/8" ODS 1 Core 58 41.8 246.84
H0141 Carly BCY 969S 1.1/8" ODS 2 Core 92.3 75.4 274.38
H0143 Carly BCY 9611S 1.3/8" ODS 2 Core 104.4 87 274.38
H0148 Carly BCY 9613S 1.5/8" ODS 2 Core 121.1 107 274.38
H0145 Carly BCY 14413S 1.5/8" ODS 3 Core 177.2 139.1 439.62
H0142 Carly BCY 9617S 2.1/8" ODS 2 Core 159 132.7 274.38
H0146 Carly BCY 14417S 2.1/8" ODS 3 Core 202.1 164.3 428.4
H0149 Carly BCY 19217S 2.1/8" ODS 4 Core 285 223 469.2
SP3405 Sporlan C-485G 5/8" ODS 1 Core 35.2 26.4 356.64
SP3407 Sporlan C-487G 7/8" ODS 1 Core 52.8 35.2 356.64
SP3416 Sporlan C-967G 7/8" ODS 2 Core 87.2 52.8 409.12
SP3408 Sporlan C-489G 1.1/8" ODS 1 Core 52.8 35.2 393.06
SP3462 Sporlan RSF-489T 1.1/8" ODS 1 Core 25.7 9.9 414.48
SP3417 Sporlan C-969G 1.1/8" ODS 2 Core 1/4” FPT connection
101.9 87.9 409.12
SP3463 Sporlan RSF-4811T 1.3/8" ODS 1 Core 31.3 12 315.00
SP3419 Sporlan C-969G 1.3/8" ODS 2 Core 123 87 294.53
SP3113 Sporlan C-14411G 1.3/8" ODS 3 Core 1/4” FPT connection
137.1 123 380.21
SP3420 Sporlan C-9613G 1.5/8" ODS 2 Core 120 106 294.53
SP3429 Sporlan C-14413G 1.5/8" ODS 3 Core 176 123 608.33
Refillable Shells - Suction LineRealcoldStock No.
Model Size Core Max. RatingkW Med Temp
Max. Rating kW Low Temp
System Price$ Excl. GST
SP3464 Sporlan RSF-4813T 1.5/8" ODS 1 core 33.8 12.7 273.11
SP3465 Sporlan RSF-4817T 2.1/8" ODS 1 core 95.0 59.8 259.18
SP3470 Sporlan RSF-9617T 2.1/8" ODS 2 core 102.0 63.3 639.39
SP3466 Sporlan RSF-4821T 2.5/8” ODS 1 core 123.0 80.9 587.98
SP3471 Sporlan RSF-9621T 2.5/8” ODS 2 core 141.0 91.4 615.83
SP3472 Sporlan RSF-9625T 3.1/8” ODS 2 core 193.0 123.0 640.46
Sporlan RSF Suction Driers: kW are based on R404a
CD93
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DirectionalLiquid Line Driers (directional/ bi-directional)
RealcoldStock No.
Model Description System Price$ Excl. GST
H0247 MA Line D111 12 gram XH9 Service Drier 1/4” ODS inlet - capillary connection outlet with separate charging port
9.38
H0250 MA Line D109 10 gram XH9 Service Drier 1/4” ODS inlet - bi-directional 4.39
H0256 MA Line D114 30 gram XH9 Service Drier 5/16” in 1/4” outlet 9.18
Note: Driers with XH9 desiccant are suitable for all refrigerants including blends and R134a
DRIERS
Briquettes To Suit Refillable Shells - InterchangeableRealcoldStock No.
Model Description System Price$ Excl. GST
H0147 Carly CCY 48HP High capacity core for use in systems where high moisture content is suspected.
36.77
H0154 Carly CCY 48N Activated carbon core used for acid wax and varnish removal and clean up in all systems where a burnout has occurred.
47.28
H0156 Carly CCY A48 Screen for Carly liquid line shells. 18.41
SP3702 Sporlan RC-4864 Catch-All core standard. 46.38
SP3703 Sporlan RC-4864-HH Catch-All activated charcoal core. 75.02
SP3704 Sporlan RCW-48 Catch-All High Water capacity core. 84.99
SP3706 Sporlan RC-10098 Catch-All Core 124.24
Refillable Shells - Suction LineRealcoldStock No.
Model Size Core Max. Rating kW System Price$ Excl. GST
H0159 Carly ACY 489S 1.1/8" ODS 1 core 39.4 282.54
H0161 Carly ACY 4811S 1.3/8" ODS 1 core 47.6 295.80
H0163 Carly ACY 4813S 1.5/8" ODS 1 core 58.0 315.18
H0165 Carly ACY 4817S 2.1/8" ODS 1 core 81.2 328.44
H0167 Carly ACY 9617S 2.1/8" ODS 2 core 85.8 375.36
H0169 Carly ACY 4821S 2.5/8" ODS 1 core 109.0 408.00
H0170 Carly ACY 9621S 2.5/8" ODS 2 core 119.5 461.04
H0201 Carly ACY 4825S 3.1/8" ODS 1 core 116.0 436.56
H0202 Carly ACY 9625S 3.1/8" ODS 2 core 167.0 461.04
Suction Line Filter Elements To Suit Above ShellsRealcoldStock No.
Model Description System Price$ Excl. GST
H0150 Carly CCY 48F Micron Filtration (Felt) Suction Line Filter Element 51.00
SP3710 Sporlan RPE-48-BD Pleated Suction Line Filter Element 59.60
AccessoriesRealcoldStock No.
Model Description System Price$ Excl. GST
SP3720 Sporlan A-685 Shell Brackets - suitable for all shells 40.86
SP3725 Sporlan AS-1704 Gaskets suitable only for Sporlan shells 4.07
Note: Carly products are colour coded: Liquid - Red; Suction - Blue; Oil - Grey
Sectional View Dryer Core
CD94
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
DRIERS
Liquid Line Ratings Standard Ratings ASHRAE-ARI: Provides comparison points. This is a basis for drier evaluation at the specified rating condi-tions. This does not determine the performance of a drier over the entire range of possible applications.
Water Capacity: The amount of water (in drops or grams) that a drier will hold at the standard temperatures and equilibrium point dryness (EPD) specified. 20 drops equal 1 gram, which is equivalent to 1 ml or 1cubic cm.
EPD is used to define the lowest possible water content in liq-uid refrigerant attainable by a filter-drier at a specific tempera-ture after it has collected specific quantity of water after equi-librium has been reached between the water in the refrigerant and the water in the drier. EPD is expressed in parts per million (ppm) by weight.
Refrigerant Flow Capacity: The maximum flow of liquid refrigerant that a drier will pass at a 1 psi pressure drop.
The refrigerant flow capacity ratings below are based on 30°C liquid temperature and refrigerant flows of:
6.8 Kg per minute per 3.5 kW for R134a 8.6 Kg per minute per 3.5 kW for R404a 6.1 Kg per minute per 3.5 kW for R410a
6.4 Kg per minute per 3.5 kW for R22 6.4 Kg per minute per 3.5 kW for R407c 9.0 Kg per minute per 3.5 kW for R507
Safety - Based on the drier shell bursting pressure. All liquid line driers must meet the requirements of Underwriters’ Labo-ratories Inc. Standard 207, “Refrigerant Containing Components and Accessories, Nonelectrical” or the fatigue stress analysis per UL 1995.
Selection RecommendationsWater Capacity & Refrigerant Flow: ARI Standard data com-parison for these factors are usually based on flow ratings of an ideal situation of a completely clean system. Flow is reduced as dirt accumulates on the filtering surface.
Filtration: Filter capacity is proportional to filtering area. Filters should be selected with an adequate reserve capacity to allow for the contamination found in most system.
Acid Removal: Acid removal ability is highly recommended.
Final Selection: Should be based on the conditions expected for each job. Extra water capacity and filtering area should also be considered.
Discharge Line MufflersMufflers are designed to eliminate pulsations in the compressor discharge line, and can be mounted in either flow direction, horizontally or vertically.
Mufflers have internal baffles, designed for minimum pressure drop. These baffles change the velocity of the discharge gasses passing through the muffler. This results in a dampening effect on high frequency sound waves in the gasses on high-speed compressors. This also irons out the pulsating waves in low speed compressors.
The muffler is sized to the discharge line of the compressor.
RealcoldStock No.
Model Description System Price$ Excl. GST
F0362 SCY 70S 7/8" ODS 96.70
F0364 SCY 90S 1.1/8" ODS 123.42
F0366 SCY 110S 1.3/8" ODS 127.50
F0370 SCY 130S 1.5/8" ODS 161.16
F0372 SCY 170S 2.1/8" ODS 484.50
DISCHARGE LINE MUFFLERS
CE95
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
Carel Electronic Controls ir33 - New Generation
Following ir32, one of CAREL’s most famous and best selling controllers, the ir300 range represents the maximum technology that CAREL offers in the field of refrigeration applications.
The top-of-the-range model characterising the new series arouses special interest as it can be fitted with all the options available: infrared remote control, programming key, repeater display, high efficiency LED display, HACCP function, real time clock, RS485 serial port, second evapora-tor defrost management, without sacrificing the 4 control relays and the 115 to 230 Vac switching power supply.
All obviously in the same dimensions as the current ir32 case!
Another unique feature concerning this new series of controllers is the possibility to manage smart defrosts, optimising the management of this function, with consequent energy savings.
Finally, one very important aspect involves the IP65 index of protection; the modern technology implemented by CAREL for the moulding of the plastic parts has allowed the protection gasket to be integrated directly into the front panel, without the need to add accessory components to the product that may create an unpleasant aesthetic and visual impact.
ELECTRONIC CONTROLS
Refrigeration ControlsAll models are fitted with a buzzer and can be connected to the Carel Supervisory system (Plant Visor) via the RS485 interface. Please note that Temperature Sensors are not included; please choose the probe that you require from the options below.
RealcoldStock No.
Model Compressor Defrost Fan Aux Infrared Real Time Clock System Price$ Excl. GST
12/24V AC/DC VersionG4501 IR33SOLR00 16A - - - YES - 178.50G4503 IR33COLR00 16A 8A 8A 8A YES - 236.64230V AC VersionG4505 IR33SOER00 8A - - - YES - 183.60G4507 IR33FOER00 8A 8A 5A - YES - 232.56115/230V AC VersionG4509 IR33COHR00 16A 8A 8A 8A YES - 282.54G4511 IR33COHB00 16A 8A 8A 8A YES YES 312.12
Temperature SensorsRealcoldStock No.
Model Description System Price$ Excl. GST
G4550 NTC015WP00 IP68 Immersion sensor 1.5m cable. Temp. range -50 - +100°C 29.99G4552 NTC060WP00 IP67 Immersion sensor 6.0m cable. Max Temp = +100°C 42.02
AccessoriesRealcoldStock No.
Model Description System Price$ Excl. GST
G4302 ABS100/75LG Standard Enclosure W/Cut-out 41.00G4306 87-84315/
RE H95AGEnclosure for All Panel Mount Controllers. Suitable for all standard 70 mm x 28 mm panel mount controllers.
54.11
G4530 IRTRRES000 Remote Control POAG4540 IROPZ48500 RS485 Serial Card POA
230V AC Din Rail Version RealcoldStock No.
Model Description System Price$ Excl. GST
G4512 DN33SOEN00 Carel 230V DIN Rail 1 stage Tstat with static defrost and 16 A relay 225.00G4513 DN33FOEN00 Carel 230V DIN Rail low temp controller with 3 relays 245.00G4536 IRDRDOXIP66 Carel DIN Rail Enclosure 81.60
CE96
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
CONTROL PANELS
Electronic Controllers - Fan Speed Controller - Pressure ActuatedRealcoldStock No.
Model Description System Price$ Excl. GST
Single Phase Controller
G1121 Saginomiya RGE-Z1N4-5 Pressure Actuated Fan speed controllerFactory set for R22, R404a, R407c and adjustable for use with R134a.For approved motors rated from 0.2 - 4 Amps. Single phase.Capillary pressure sensorRange 8 - 28 Bar adjustable4 Bar fixed proportional band
361.08
G1123 Saginomiya RGE-Z1N6-5 Pressure Actuated Fan speed controllerFactory set for R410a Refrigerant.Single Phase, 4 Amps, IP54.
POA
G1124 Saginomiya RGE-Z1Q4-5 Pressure Actuated Fan speed controllerFactory set for R22, R404a, R407c Refrigerants adjustable for use with R134a. Single Phase, 8 Amps, IP54.
481.44
Note: Refer to “CT” section for Mechanical Thermostats
Control Panels
CF97
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FANS
Fan MotorsRealcoldStock No.
Watts Rpm Shaft Mounting/Models
System Price$ Excl. GST
D0121 4 2400 3/16” 2 bolt 50 mm spacing 98.00
D0122 7 1300 D.Plate 3 bolt rear 66.00
D0165 10 1300 D.Plate 3 bolt rear 59.00
D0123 10 1300 D.Plate 4 bolt 78.00
D0124 16 1300 D.Plate 4 bolt Rondo 140-700 CM 77.00
D0162 20 1300 5/16" 3/4 bolt front/rear 132.00
D0125 25 1300 D.Plate Rear Tapped 4 Bolt 99.81
D0129 25 1300 8 mm 3 bolt rear 2 bolt bottom 150.00
AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
D0240 Capacitor 5 mfd suits D0230, D0231 POA
D0241 Capacitor 12.5 mfd suits D0232 POA
Features & Benefits
• Motors Single Phase 50/60Hz (Check first)
• CCW = Counter Clockwise - Facing Shaft
• CW = Clockwise Facing Shaft
• Note: 3 bolt mount 70 mm PCD - 4 bolt mount 54 mm PCD
Bi Directional Fan MotorsRealcoldStock No.
Watts Rpm Shaft Mounting/Models
System Price$ Excl. GST
D0160 40 1300 5/16" 3/4 bolt front and rear 117.00
D0133 60 1300 5/16" 3/4 bolt front and rear 176.00
D0137 90 1440 1/2" 120 x 216 Base - complete 424.00
D0231 230 950 1/2" Foot Mount - 6 Pole POA
D0232 600 900 1/2" Clamp - 1 speed RAC POA
D0134* 180 1400 1/2" Clamp - 3 speed POA
D0169 180 1380 1/2" Clamp bracket POA
* Three Phase
CF98
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FAN MOTOR ASSEMBLY
External Rotor Motor TypeRealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
System Price$ Excl. GST
Diameter 300 mm
R0930 EBM 300 mm Fan Motor Assembly 1 phase
300 80 1380 Induce 260.00
R0930B EBM 300 mm Condensor Fan Motor Assembly 75W 1 phase CW
300 75 1250 Blower 260.00
Diameter 400 mm
R0940 EBM 400 mm Fan Motor Assembly 1phase
400 180 1380 Induce 429.00
R0940B EBM 400 mm Fan Motor Assembly 1 phase
400 180 1380 Blower 429.00
Diameter 450 mm
EBM 450 mm Condensor Fan Motor Assembly 450W 1 phase
450 450 1325 Induce 600.00
Diameter 500 mm
R0950 EBM 500 mm Fan Motor Assembly 1 phase
500 420 1300 Induce 745.00
Diameter 630 mm
R0963 EBM 630 mm Fan Motor Assembly 3 phase
630 880 1320 Induce 1,007.76
Compact Fan Motor Assembly - Computer Rooms etc.RealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
System Price$ Excl. GST
D0150 EBM Motor Assembly - fan and guard. 172 x 150 x 55 mm
150 45/39 2800 Induce POA
D0152 EBM 28W Motor Assembly - fan and guard. 172 x 150 x 38 mm
150 29 2800 Induce POA
D0154 EBM 19W Motor Assembly - fan 120 x 120 x 38 mm
120 19 2650 Induce POA
Blade & Motor Type - 3 Piece Fan AssemblyRealcoldStock No.
Brand Description Diameter (mm)
Watts Rpm ApplicationInduce/Blower
System Price$ Excl. GST
D0200 Supco SM672 Universal Motor Kit - Single Speed Bi Directional c/w 2 blades and accessories
100/138 5 3000 Induce/ Blower
51.00
Fan Motor Assembly
CF99
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FANS
Fan BladesRealcoldOr der No.
Description System Price$ Excl. GST
Diameter Blade Pitch Rotation Min. Watts Bore
Induced Type
D0105 178 mm Postmix 5 40° CCW 7 Driveplate 36.41
D0106 200 mm (8”) 5 40° CCW 10 Driveplate 30.37
D0107 229 mm Skope/Cyclone 5 40° CCW 22 Driveplate 36.41
D0111 200 mm (7.7/8”) 5 28° CCW 5 Driveplate 27.58
D0109 254 mm (10”) 5 30° CCW 22 8 mm 34.76
D0118 254 mm (10”) 5 25° CCW 10 Driveplate 34.22
D0115 305 mm (12”) 3 20° CCW 22 Driveplate 33.68
D0117 356 mm (14”) 3 25° CCW 60 5/16" 97.08
D0119 381 mm (15”) 4 35° CCW 120 1/2" 128.52
Reverse Pitch (Blower Type)
D0309 254 mm (10”) 5 30° CCW 22 8 mm 37.54
Miscellaneous Fan Blades
D0015 100 mm (4”) 5 Plastic 30° CW Blower
4 1/8" 7.07
D0027 125 mm (5”) 5 Plastic 25° CW Blower
4 3/16" 6.00
M0165 862-022Y-1 (10”) 5 Plastic 30° CW Blower
20 5/16" 28.71
M0166 862-717Y (7”) 3 Plastic 25° CCW Induced
4 3/16" 20.99
Fan Blades To Suit RAC Condensers (indent only)RealcoldStock No.
Description System Price$ Excl. GST
D0235* 16” suits RAC 5800, 7300 D POA
D0236* 20” suits RAC 10500, 14000, 17000 D POA
D0237* 26” suits RAC 20000, 25000, 30000, 40000, 55000, 70000, 80000 D POA
* Indent items
D0105
D0116
CF100
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
Brass Fittings - FlareRealcoldStock No.
Description System Price$ Excl. GST
Flare Nuts
J0401 1/4" FF 2.09
J0402 5/16" FF 5.36
J0403 3/8" FF 2.75
J0404 1/2" FF 4.08
J0405 5/8" FF 5.81
J0406 3/4" FF 9.18
Reducing Flare Nuts
J0421 3/8" MF - 1/4" Tube 3.11
J0422 1/2" MF - 3/8" Tube 5.51
J0423 5/8" MF - 1/2" Tube 5.92
Male Flare Union
J0431 1/4" MF x 1/4" MF 1.43
J0432 5/16" MF x 5/16” MF 4.03
J0433 3/8" MF x 3/8" MF 2.55
J0434 1/2" MF x 1/2" MF 3.37
J0435 5/8" MF x 5/8" MF 5.41
J0436 3/4" MF x 3/4" MF 14.74
Double Flare Reducing Unions
J0452 3/8" MF x 1/4" MF 3.57
J0454 1/2" MF x 1/4" MF 6.68
J0456 1/2" MF x 3/8" MF 8.82
J0459 5/8" MF x 3/8" MF 9.54
J0460 5/8" MF x 1/2" MF 11.07
J0464 3/4" MF x 1/2" MF 14.74
J0465 3/4" MF x 5/8" MF 20.50
Male Flare - Female Flare. Reducing Unions c/w Gaskets
J0472 1/4" MF x 3/8" FF 4.13
J0474 1/4" MF x 1/2" FF 9.95
J0486 3/8" MF x 1/4" FF 4.59
J0475 3/8" MF x 1/2" FF 5.76
J0488 1/2" MF x 3/8" FF 9.74
J0479 1/2" MF x 5/8" FF 18.41
J0491 5/8" MF x 1/2" FF 6.53
Swivel Unions
J0541 1/4" FF Connectors 9.23
J0543 3/8" FF Connectors 9.23
J0544 1/2" FF Connectors 11.07
J0545 5/8" FF Connectors 13.16
Female Flare Connectors
J0551 1/4" FF c/w Gaskets 5.87
J0553 3/8" FF c/w Gaskets 12.65
J0554 1/2" FF c/w Gaskets 11.58
RealcoldStock No.
Description System Price$ Excl. GST
Male Flare - Male Pipe Unions
J0501 1/4” MF - 1/8” MP 1.53
J0501A 5/16” MF - 1/8” MP 5.20
J0502 1/4” MF - 1/4” MP 2.55
J0502A 5/16” MF - 1/4” MP 8.67
J0504 1/4” MF - 3/8” MP 2.96
J0507 3/8” MF - 1/8” MP 2.96
J0508 3/8” MF - 1/4” MP 2.96
J0510 3/8” MF - 3/8” MP 2.96
J0511 3/8” MF - 1/2” MP 4.49
J0515 1/2” MF - 1/4” MP 8.52
J0517 1/2” MF - 3/8” MP 3.62
J0518 1/2” MF - 1/2” MP 4.49
J0523 5/8” MF - 3/8” MP 7.80
J0524 5/8” MF - 1/2” MP 4.95
J0525 5/8” MF - 3/4” MP 6.38
J0530 3/4” MF - 1/2” MP 15.76
J0531 3/4” MF - 3/4” MP 15.25
Male Flare - Female Pipe Unions
J0536 1/4” MF - 1/8” FP (Gauge Fitting)
1.94
J0535 3/8” MF - 1/2” FP (Gauge fitting U0210)
11.58
J0537 1/4” MF - 1/4” FP 2.65
J0538 1/4” MF - 3/8” FP 10.10
J0539 1/4” MF - 3/4” FP (Cyl. Adaptor)
14.74
J0540 3/8” MF - 3/4” FP (Cyl. Adaptor)
8.36
Acme Adaptor
J0742 1/4" FF - 1/2" Male Acme
6.99
J0743 1/2" Female Acme - 1/4" MF
19.38
J0744 14mm Male - 1/4” MF (Suits Auto A/C Couplers)
6.27
Thread Sealants
N0058 Nylog Blue 30ml POE Oil Sys
20.10
N0059 Nylog Red 30ml Mineral Oil
20.10
N0063 Leak-Lock Tube 39ml 9.80
N0065 Leak-Lock Brush Top 21.15
N0069 Teflon Thread Seal Tape
3.60
Note: MP and FP are NPT (National Pipe Thread).
CF101
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
Brass Fittings - FlareRealcoldStock No.
Description System Price$ Excl. GST
Double Flare Elbows
J0561 1/4" Male Flare 6.63
J0563 3/8" Male Flare 9.38
J0564 1/2" Male Flare 10.10
J0565 5/8" Male Flare 17.90
J0566 3/4" Male Flare 29.43
Male Flare - Male Pipe Elbows
J0590 1/4" MF x 1/8" MP 5.61
J0591 1/4" MF x 1/4" MP 5.61
J0592 1/4" MF x 3/8" MP 6.99
J0594 3/8" MF x 1/4" MP 6.99
J0595 3/8" MF x 3/8" MP 6.99
J0596 3/8" MF x 1/2" MP 10.10
J0598 1/2" MF x 1/4" MP 10.10
J0599 1/2" MF x 3/8" MP 11.07
J0600 1/2" MF x 1/2" MP 11.07
J0601 5/8" MF x 1/2" MP 18.92
J0604 3/4" MF x 3/4" MP 28.41
Male Flare Tees
J0610 1/4" MF 5.61
J0612 3/8" MF 14.74
J0613 1/2" MF 18.41
J0614 5/8" MF 21.01
J0615 3/4" MF 41.00
Male Flare - Male Pipe Tees
J0617 1/4" MFx1/4" MFx1/8" MP
6.83
J0618 1/4" MFx1/4" MFx1/4" MP
6.83
J0619 3/8" MFx3/8" MFx1/4" MP
8.62
Flare Seal Plugs
J0690 1/4” MF 1.43
J0691 5/16” MF 8.36
J0692 3/8" MF 2.40
J0693 1/2" MF 6.63
J0694 5/8" MF 7.80
J0695 3/4" MF 9.23
RealcoldStock No.
Description System Price$ Excl. GST
Pipe Plugs
J0731 1/4" MP 2.24
J0732 3/8" MP 4.79
J0733 1/2" MP 4.34
Pipe Bushings
J0750 1/4" MPx1/8" FP 1.33
J0752 3/8" MPx1/4" FP 7.29
J0754 1/2" MPx3/8" FP 7.91
J0756 3/4" MPx1/2" FP 9.74
J0739 1/8" MPx1/8" FP Elbows
6.94
J0740 1/4" MPx1/4" FP Elbows
4.13
Flare Seal Caps
J0770 1/4” Flare 1.12
J0771 5/16” Flare 3.57
J0772 3/8" Flare 1.99
J0773 1/2" Flare 2.45
J0774 5/8" Flare 3.57
Copper Flare Bonnets
J0790 1/4” Bonnet 1.07
J0791 5/16” Bonnet 1.94
J0792 3/8” Bonnet 1.07
J0793 1/2” Bonnet 1.58
J0794 5/8” Bonnet 1.94
J0795 3/4” Bonnet 3.57
Copper Flare Gaskets
J0810 1/4" Gasket 0.56
J0811 5/16” Gasket 1.63
J0812 3/8" Gasket 0.87
J0813 1/2" Gasket 0.92
J0814 5/8" Gasket 1.02
J0815 3/4" Gasket 2.70
Note: MP and FP are NPT (National Pipe Thread). Refer to CC63 for Thread Sealants.
CF102
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
Copper FittingsRealcoldStock No.
Description R410a System Price$ Excl. GST
Copper Elbows - 45°, Sweat
J0993 5/8" ü 1.73
J0994 3/4" ü 4.64
J0995 7/8" ü 3.01
J0998 1.1/8" 7.55
J0999 1.3/8" 11.58
J1000 1.5/8" 13.16
J1001 2.1/8" 22.08
J0988 2.5/8" 48.35
J0989 3.1/8" 86.70
Copper Elbows - 90°, Sweat
J1002 1/4" x 90° ü 2.24
J1003 3/8" x 90° ü 2.30
J1004 1/2" x 90° ü 1.89
J1005 5/8" x 90° ü 1.73
J1110 3/4" x 90° ü 3.72
J1111 7/8" x 90° ü 4.28
J1113 1.1/8" x 90° 6.17
J1114 1.3/8" x 90° 8.87
J1115 1.5/8" x 90° 13.67
J1116 2.1/8” x 90° 26.27
J1117 2.5/8" x 90° 46.77
J1118 3.1/8" x 90° 68.29
Copper Elbows - 45°, Sweat, Long Radius
J8046* 1.1/8” x 45° lr ü 20.50
J8049* 1.3/8” x 45° lr ü 26.27
J8051* 1.5/8” x 45° lr ü 48.35
Copper Elbows - 90°, Sweat, Long Radius
J1154 1/2" x 90° lr ü 2.50
J1155 5/8" x 90° lr ü 3.32
J1156 3/4" x 90° lr ü 4.18
J1157 7/8" x 90° lr ü 6.43
J8019 1.1/8” x 90° lr ü 21.78
J1159 1.1/8" x 90° lr 9.08
J8020A 1.3/8" x 90° lr ü 24.74
J1161 1.3/8" x 90° lr 15.76
J8023A 1.5/8" x 90° lr ü 35.24
J1163 1.5/8" x 90° lr 25.25
J1165 2.1/8” x 90° lr 38.91
J1167 2.5/8” x 90° lr 82.52
J1169 3.1/8” x 9° lr 146.88
RealcoldStock No.
Description R410a System Price$ Excl. GST
Copper Return Bends - 180°, Sweat
J1120 3/8" x 180° ü 4.95
J1121 1/2" x 180° ü 6.17
J1122 5/8” x 180° ü 13.16
J1123 3/4" x 180° ü 22.59
J1123D 7/8" x 180° ü 23.15
J1125 1.1/8" x 180° 36.26
J1126 1.3/8" x 180° 45.75
J1127 1.5/8" x 180° 53.60
J1128 2.1/8" x 180° 129.54
Copper Tees - Sweat
J1133 1/4" ü 2.14
J1134 3/8" ü 3.16
J1135 1/2" ü 3.37
J1136 5/8" ü 2.09
J1137 3/4" ü 7.34
J1138 7/8" ü 6.89
J8104 1.1/8” ü 28.41
J1140 1.1/8" 12.65
J1141 1.3/8" 21.57
J1142 1.5/8" 28.41
J1144 2.1/8" 57.27
J1145 2.5/8" 80.94
J1146 3.1/8" 197.88
Copper Couplings (rolled stop)
J1203 3.8" ü 0.71
J1204 1/2" ü 1.33
J1205 5/8" ü 0.82
J1206 3/4" ü 2.14
J1207 7/8" ü 1.48
J8133A 1.1/8" ü 5.66
J1209 1.1/8" 3.11
J8136 1.3/8" ü 15.76
J1211 1.3/8" 5.41
J8138A 1.5/8" ü 17.90
J1212 1.5/8" 6.99
J1213 2.1/8" 12.09
J1214 2.5/8" 30.50
J1215 3.1/8" 39.93
* R410a compatible.
CF103
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS & FASTENERS
Fittings & FastenersRealcoldStock No.
Description R410a System Price$ Excl. GST
Copper Reducing Bushes
J1308 3/4" x 1/2" ü 4.95
J1309 3/4" x 5/8" ü 3.62
J1312 7/8" x 1/2" ü 3.42
J1311 7/8" x 5/8" ü 2.60
J1310 7/8" x 3/4" ü 2.81
J8192A 1.1/8" x 5/8" ü 7.65
J1312B 1.1/8" x 5/8" 5.10
J1314 1.1/8" x 3/4" 4.54
J8199A 1.1/8" x 7/8" ü 6.89
J1313 1.1/8" x 7/8" 4.18
J1319 1.3/8" x 5/8" 7.60
J8204A 1.3/8" x 7/8" ü 12.09
J1318 1.3/8" x 7/8" 7.60
J1317 1.3/8" x 1.1/8" 7.60
J1322 1.5/8" x 7/8" 9.79
J1321 1.5/8" x 1.1/8" 9.79
J8217* 1.5/8" x 1.3/8" ü 11.58
J1320 1.5/8" x 1.3/8" 8.57
J1326 2.1/8" x 1.1/8" 38.91
J1325 2.1/8" x 1.3/8" 18.92
J1324 2.1/8" x 1.5/8" 17.90
J1330 2.5/8" x 1.3/8" 38.35
J1332 2.5/8" x 1.5/8" 27.85
J1329 2.5/8" x 2.1/8" 31.52
J1331 3.1/8" x 2.5/8" 47.84
Larger fitting sizes fit into a bend, tee or coupling, smaller fitting sizes fit over OD tube.
Copper Caps
J1345 5/8" ü 1.94
J1346 3/4" ü 4.69
J1347 7/8" ü 1.38
J1351 1.1/8" 2.91
J1353 1.3/8" 4.28
J1355 1.5/8" 6.27
J1361 2.1/8" 14.23
J1366 2.5/8" 35.24
J1367 3.1/8" 79.36
RealcoldStock No.
Description R410a System Price$ Excl. GST
Copper ‘P’ Traps
J1498 5/8" ü 23.15
J1499 3/4" ü 27.34
J1500 7/8" ü 29.99
J1501 1.1/8" 44.68
J1502 1.3/8" 59.93
J1503 1.5/8" 92.46
J1504 2.1/8" 163.20
Copper Saddles (single)
J2010 1/4” 1.07
J2011 3/8” 1.07
J2012 1/2” 1.12
J2013 5/8” 1.07
J2014 3/4” 1.12
J2015 7/8” 1.33
J2017 1.1/8” 1.99
J2018 1.3/8” 2.35
J2019 1.5/8” 2.70
J2020 2.1/8” 3.06
Pipe Clamps (brass)
J1249 for 5/8" OD tube 6.48
J1250 for 7/8" OD tube 7.29
J1251 for 1.1/8" OD tube 8.72
J1252 for 1.3/8" OD tube 8.67
J1253 for 1.5/8" OD tube 11.58
J1254 for 2.1/8" OD tube 12.65
J1255 for 2.5/8" OD tube 17.34
J1257 Brass Plate tapped to 10 mm
3.47
J1258 Screwed Brass Rod 10 mm x 610 mm long
22.59
J1259 Brass Nut 10 mm (for locking rod)
1.07
Note: MP and FP are NPT (National Pipe Thread). Refer to CC63 for Thread Sealants.
* R410a compatible
CF104
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS & FASTENERS
RealcoldStock No.
Description System Price$ Excl. GST
ZP Threaded Rod (galvanised)
J1260 10 mm x 1000 mm 4.44
J1262 10 mm Nut to suit 0.46
J1263 10 mm x 32 mm ZP Washer
0.41
Simplefix Multi Purpose - Pipe Support Systems
J1265 Simplefix 100 m ZP Backing Plate
1.84
J1270 Simplefix Strap (galv.) 25 metre x 0.6 mm
55.69
J1271 5 metre x 0.6 mm 13.67
J1275 Rubber Insertion Strip 5 metre coil
18.92
J1279 Top Bracket 0.82
J1278 Clip Lock 0.51
Fittings & FastenersRealcoldStock No.
Description System Price$ Excl. GST
Simplefix Tube Hangers Hinged
J1701 Hinged 1/2-5/8 3.06
J1702 Hinged 5/8-3/4 3.21
J1703 Hinged 7/8 3.42
J1704 Hinged 1.1/8 3.67
J1705 Hinged 1.3/8 3.98
J1706 Hinged 1.5/8 4.49
J1708 Hinged 2.1/8 6.12
J1710 Hinged 2.5/8 7.50
J1713 Hinged 3.1/8 11.58
Simplefix Tube Hangers Heavy Duty
J1720 Heavy Duty 3/8-1/2 3.06
J1721 Heavy Duty 1/2-5/8 3.06
J1722 Heavy Duty 3/4 3.21
J1723 Heavy Duty 7/8 3.42
J1724 Heavy Duty 1.1/8 3.67
J1725 Heavy Duty 1.3/8 3.98
J1726 Heavy Duty 1.5/8 4.49
J1728 Heavy Duty 2.1/8 6.12
J1730 Heavy Duty 2.5/8 7.50
J1733 Heavy Duty 3.1/8 8.67
Realcold offer a comprehensive range of screws and fastenings. Visit your store to view the full range.
Fasteners - Cable TiesRealcoldStock No.
Description Quantity Per Pack System Price$ Excl. GST
H0084 2.5 x 100 mm Natural 100 0.15
H0085 2.5 x 100 mm Black 100 0.15
H0086 3.5 x 150 mm Natural 100 0.20
H0087 3.5 x 150 mm Black 100 0.20
H0088 4.6 x 200 mm Natural 100 0.26
H0089 4.6 x 200 mm Black 100 0.26
H0090 4.6 x 385 mm Black 100 0.36
H0091 4.6 x 385 mm Natural 100 0.36
H0094 7.6 x 390 mm Natural 100 0.51
H0095 7.6 x 390 mm Black 100 0.51
H0096 7.6 x 465 mm Natural 100 1.02
H0097 7.6 x 465 mm Black 100 1.07
H0098 7.6 x 760 mm Black 50 1.94
CF105
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
Thermoplastic - NylonRealcoldStock No.
Description Recommended max. safe working load
System Price$ Excl. GST
Threaded Rod
J3010 Nylon Threaded Rod M10 x 1.0 metre 80 Kg 15.25
J3012 Nylon Threaded Rod M12 x 1.0 metre 120 Kg 17.90
Buffalo Panel Bolts
J3180 Nylon Panel Bolts M10 x 150 mm 80 Kg 6.43
J3182 Nylon Panel Bolts M10 x 250 mm 80 Kg 7.55
J3190 Nylon Panel Bolts M12 x 150 mm 120 Kg 7.09
J3192 Nylon Panel Bolts M12 x 250 mm 120 Kg 8.87
Full Hexagonal Nuts
J3040 Nylon Full Hex Nuts M10 80 Kg 0.66
J3042 Nylon Full Hex Nuts M12 120 Kg 0.77
Washer Faced Nuts
J3060 Nylon Washer Faced Nut M10 0.71
J3062 Nylon Washer Faced Nut M12 0.87
Dome Nuts
J3080 Nylon Dome Nut M10 80 Kg 0.71
J3082 Nylon Dome Nut M12 120 Kg 1.07
Buffalo T-Nut
J3160 Nylon T-Nut M10 80 Kg 11.07
J3162 Nylon T-Nut M12 120 Kg 15.76
Washer - Standard
J3110 Nylon M10 Washer 10.5 mm ID x 21.0 mm OD x 2.0 mm Thick 0.31
J3112 Nylon M12 Washer 13.0 mm ID x 24.0 mm OD x 2.5 mm Thick 0.31
Washer - Load Bearing
J3130 Nylon M10 Washer 10.5 mm ID x 45 mm OD x 4.5 mm Thick 1.73
J3131 Nylon M10 Washer 10.5 mm ID x 75 mm OD x 4.5 mm Thick 4.28
J3142 Nylon M12 Washer 13.0 mm ID x 50 mm OD x 4.5 mm Thick 1.84
J3143 Nylon M12 Washer 14.0 mm ID x 75 mm OD x 4.5 mm Thick 4.28
Mushroom Head Bolts - (coolroom bolts)
J1285 Mushroom Head Bolt M16 x 250 mm 3.16
J1287 Mushroom Head Bolt M16 x 300 mm 4.44
J1290 Nylon Nut M16 1.22
J1292 Nylon Washer M16 0.82
Threaded Rod
Mushroom Head Bolt
Buffalo T-Nut
Buffalo Panel Bolt
Dome Nut
Washer Faced Nut
CF106
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
Evaporator Mounting Kits - NylonRealcoldStock No.
Model Contains Recommended max. safe working load
System Price$ Excl. GST
Bluemay Kits
J3210 Bluemay Chiller 4 Bolt Kit
Bolt - 10 mm diameter and 150 mm length
4 x J3040 nut
4 x J3060 washer faced nut
4 x J3130 washer
4 x J3180 bolt
320 Kg 39.42
J3212 Bluemay Freezer Kit 4 Bolt Kit
Bolt - 10 mm diameter and 250 mm length
4 x J3040 nut
4 x J3060 washer faced nut
4 x J3130 washer
4 x J3182 bolt
320 Kg 43.61
J3211 Bluemay Chiller 6 Bolt Kit
Bolt - 10 mm diameter and 150 mm length
6 x J3040 nut
6 x J3060 washer faced nut
6 x J3130 washer
6 x J3180 bolt
480 Kg 57.78
J3213 Bluemay Freezer 6 Bolt Kit
Bolt - 10 mm diameter and 250 mm length
6 x J3040 nut
6 x J3060 washer faced nut
6 x J3130 washer
6 x J3182 bolt
480 Kg 65.69
• The use of steel or brass nuts with Thermoplastic rod is not recommended.
• See technical data for temperature limitations. Not recommended for below -30ºC.
• Care should be taken not to over-tighten nuts when used with Thermoplastic threaded rod. Nuts should be tightened by hand and given half a turn with a spanner.
Features & Benefits
Nylon threaded rod and Buffalo bolts, together with associated products, have been at the heart of Bluemay’s manufacturing operation since 1973. This very special range is widely held in high regard by customers who have come to rely on its exceptional qualities and high standard of production.
Threaded Rod, Thermoplastic Nuts and Washers are available in Nylon 66, one of the strongest grades of engineering plastic. This remarkable material has many features, including a melting point of 260˚C, a tensile strength at 23˚C of 62-83 N/mm², and a 1-3% deformation under load 14N/mm² after 24 hours, at 50˚C.
The products in the Bluemay range are:
• Efficient thermal and electrical insulators
• Non-corrosive
• Lightweight and easy to handle
• Hygenic
CF107
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
InsulclampTube and pipe support. INSULCLAMP - effective pipe support and good isolation properties reduce transmission of vibration and noise. Withstands temperatures from -30ºC to +125ºC, good resistance to oil, UV rays etc.
RealcoldStock No.
Size Description Sold Per System Price$ Excl. GST
“A” (mm) “B” (mm)
J1602 1/4" 31.80 7.9 each 3.37
J1603 3/8” 34.93 19.05 each 3.47
J1604 1/2” 38.10 23.81 each 3.47
J1605 5/8” 42.75 25.40 each 3.62
J1606 3/4” 44.45 30.16 each 3.67
J1607 7/8” 49.21 33.34 each 3.77
J1608 1.1/8” 53.98 36.51 each 4.13
J1609 1.3/8” 60.33 44.45 each 4.44
J1610 1.5/8” 73.03 53.98 each 5.56
J1611 2.1/8” 88.90 68.26 each 7.45
J1612 2.5/8” 101.60 80.96 each 11.58
J1613 3.1/8” 114.30 93.66 each 13.16
J1614 4.1/8" 139.70 146.05 each 15.25
J1620 40 x 20mm Aluminium Channel 1 metre lengths length 19.99
Studding ClipThe Studding Clip is a plastic clip for supporting copper tube or PVC pipe.
RealcoldStock No.
Description Sold Per System Price$ Excl. GST
J1681 22 mm Studding Clip each 1.55
J1682 25 mm Studding Clip each 1.60
J1684 32 mm Studding Clip each 1.70
AC1205 Galvanised steel channel 3 metre length M1000 69.36
BBJ Pipe FittingsRealcoldStock No.
Description Height Width Depth Approx Pipe Size + Insulation
System Price$ Excl. GST
J1650 BBJ Suspender # 2 75 mm 55 mm 35 mm 5/8” gas, 3/8” liquid 6.48
J1651 BBJ Suspender # 3 87 mm 62 mm 35 mm 7/8” gas, 1/2” liquid 6.63
J1652 BBJ Suspender # 4 100 mm 70 mm 35 mm 1.1/8” gas, 5/8” liquid 6.73
J1660 BBJ Griplock # 1 30 mm 54 mm 1/2” gas, 1/4” liquid 3.62
J1661 BBJ Griplock # 2 32 mm 60 mm 5/8” gas, 3/8” liquid 3.62
J1662 BBJ Griplock # 3 37 mm 67 mm 7/8” gas, 1/2” liquid 3.77
J1663 BBJ Griplock # 4 46 mm 80 mm 1.1/8” gas, 5/8” liquid 4.13
J1670 BBJ Pipe Tie Base BH1 6.17
J1671 BBJ Pipe Tie Base BH2 6.38
J1672 BBJ Pipe Tie Base BH3 6.58
J1674 BBJ Pipe Tie 250 mm 3.11
J1675 BBJ Pipe Tie 300 mm 3.32
J1676 BBJ Pipe Tie 350 mm 3.57
J1677 BBJ Pipe Tie 400 mm 4.54
J1678 BBJ Pipe Tie 450 mm 4.95
CF108
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
FITTINGS
LocksetsRealcoldStock No.
Model Description System Price$ Excl. GST
V0116 Efco style R5710 is supplied complete with strike. Lockable handle. 167.28
V0121 Efco style R5612 complete with internal release. Adjustable strike, offset 16 to 32mm
231.54
V0300 Shineyear CH1178 complete with internal release. Adjustable strike, offset 45 to70 mm
188.70
V0356 Shineyear Internal Release Mechanism to suit CT/CH-1178 29.43
V0302 Shineyear CH-1200P Edgemount type. Adjustable strike, offset 18 to 22mm 28.92
HingesRealcoldStock No.
Model Description Approx.Overall Length
AdjustableOffset
System Price$ Excl. GST
V0151 Efco R40 110 mm 19 - 25 mm 43.61
V0146 LH Self Closing Rising Hinge (Same as Efco R187 24.17
V0147 RH Self Closing Rising Hinge (Same as Efco R187) 24.17
V0316 Shineyear CH1450 250 mm 32 - 50 mm 81.96
V0318 Shineyear CH1460 250 mm 32 - 60 mm 87.77
V0320 Shineyear CH1470 335 mm 40 - 70 mm 107.10
Style Spares - EfcoRealcoldStock No.
Description System Price$ Excl. GST
V0117 Efco R5722 strike for R5712 and R5710. Adjustable offset 19 to 25 mm 35.24
V0122 Efco R5622 strike for R5612. Adjustable offset 0 to 16 mm 147.90
V0124 Efco R5612 Internal Release Handle for R5612 47.28
V0126 Efco V26A Push Rod for R5612 19.99
V0128 Efco Spring to suit R5612 9.08
V0116
V0121
V0300
V0151
V0146V0316
Accessories - Efco
A. V0126
B. V0124
C. V0129
D. V0117
E. V0122/3
A
C
B
E
D
CH109
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
HEAT EXCHANGERS
Doucette Heat ExchangersNominal capacities kWs at +5°C SST 5.5K of subcooling for below heat exchangers
RealcoldStock No.
Model Description System Price$ Excl. GST
Nom. HP R22 R404a R134a Connection Sizes Dimensions (mm)Diam. x Length
Liq. Vol. cm³
Suction Liquid
F0045 SLHE 1 1 4.52 3.17 4.09 5/8" SW 3/8" SW 28 344 44 POA
F0046 SLHE 1.1/2 1.1/2 6.30 4.20 5.83 7/8" SW 3/8" SW 35 363 52 POA
F0048 SLHE 3 3 8.21 4.69 7.59 1.1/8" SW 1/2" SW 42 375 58 POA
F0049 SLHE 5 5 14.51 9.67 12.85 1.3/8" SW 5/8" SW 54 356 255 POA
F0050 SLHE 7.1/2 7.1/2 17.79 11.43 15.19 1.5/8” SW 5/8" SW 54 425 306 POA
• Doucette Heat Exchangers are all copper construction, suitable for all refrigerants. Type L copper fluted suction tubes.
• Single and multiple tube configurations to reduce velocity and pressure drop. High temperature brass brazed. UL listed
Working Principle:
Wilchwitzer Thermo-Technik (WTT) consists of a pack of pressed stainless steel plates which are brazed together with 99.9% copper in a vacuum furnace. When assembling the pack every alternate plate is rotated by 180° to produce two separate flow channels in which the heat exchange media flow in opposite directions. All contact points are joined by brazing. This process makes it possible to achieve very high mechanical strength, i.e. high pressure resistance. The corrugated plates generate high turbulence during fluid through put, which promotes efficient heat exchange even with a low flow rate.
Applications: WTT can be utilized for a wide range of gaseous and non clogging liquid media: Water; Oil; Glycol; Freons. Typical applications include:
• Floor Heating • Condensers and evaporators in Chillers & Heatpumps• Industrial processes• Hydraulic oil cooling• Heat Recovery• Desuperheaters
Advantages:
• Compactunit,lowweight • Highoperationaltemperaturesandhighworkingspressures.• Lessspacerequired • SUS316(AISI316)(W-1.4401)stainlesssteelforeffectivecorrosionresistance.• Nogaskets,noleaks • Easyinstallationandreplacement,lowmaintenancerequirements.• High heat transmission rate
Heat Exchangers
CI110
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
INSULATION
Tube InsulationRealcoldStock No.
Description Lengths Per Ctn System Price$ Excl. GSTID Wall Thickness
Inches mm Inches mm
N4109FR 3/8" 9 1/2" 13 70 5.13N4113FR 1/2" 13 1/2" 13 60 6.66N4116FR 5/8" 16 1/2" 13 50 8.37N4119FR 3/4" 19 1/2" 13 40 9.12N4122FR 7/8" 22 1/2" 13 32 10.16N4125FR 1” 25 1/2" 13 30 9.99N4128FR 1.1/8" 28 1/2" 13 28 11.60N4135FR 1.3/8" 35 1/2" 13 20 13.04N4142FR 1.5/8" 42 1/2" 13 18 14.94N4148FR 1.7/8" 48 1/2" 13 16 17.32N4154FR 2.1/8" 54 1/2" 13 14 17.90N4160FR 2.3/8" 60 1/2" 13 12 19.60N4167FR 2.5/8" 67 1/2" 13 10 24.83N4180FR 3.1/8" 80 1/2" 13 8 29.54N4190FR 3.1/2” 90 1/2" 13 8 28.69N4209FR 3/8" 9 3/4" 19 32 7.25N4213FR 1/2" 13 3/4" 19 32 9.36N4216FR 5/8" 16 3/4" 19 28 12.11N4219FR 3/4" 19 3/4" 19 24 11.89N4222FR 7/8" 22 3/4" 19 20 14.43N4228FR 1.1/8" 28 3/4" 19 18 19.33N4235FR 1.3/8" 35 3/4" 19 16 22.63N4242FR 1.5/8" 42 3/4" 19 12 22.61N4248FR 1.7/8" 48 3/4" 19 10 31.17N4254FR 2.1/8" 54 3/4" 19 8 28.63N4260FR 2.3/8" 60 3/4" 19 8 32.00N4267FR 2.5/8" 67 3/4" 19 8 34.91N4276FR 3” 76 3/4" 19 6 40.20N4280FR 3.1/8" 80 3/4" 19 6 41.07N4290FR 3.1/2" 90 3/4" 19 6 46.19N4319FR 3/4” 19 1” 25 18 23.88N4322FR 7/8" 22 1" 25 16 27.69N4328FR 1.1/8" 28 1" 25 12 25.02N4335FR 1.3/8" 35 1" 25 10 29.37N4342FR 1.5/8" 42 1" 25 8 33.26N4348FR 1.7/8" 48 1" 25 8 37.82N4354FR 2.1/8" 54 1" 25 8 53.92N4360FR 2.3/8” 60 1" 25 6 46.09N4367FR 2.5/8" 67 1” 25 6 49.66N4380FR 3.1/8" 80 1” 25 6 59.05
Maxflex™ is made from light weight elastomeric material specially designed for thermal insulation usage. Maxflex™ is CFC free, HCFC free, ODP zero, asbestos free, dust free and fibre free. The molecular structure of Maxflex™ is characterized by a large number of fine cross-linked closed cells which provides:
a) Stable and low thermal conductivity value (K-Value).
b) Excellent moisture and vapour resistance due to its dense surface skin and the closed cell structure.
c) Outstanding ozone / UV and weather resistance.
d) Flexibility, making installation work easy and neat.
e) Ideal thermal insulation to prevent condensation problems on chilled water pipes or refrigerant lines, and also prevents frost formation.
Maxflex™ retards heat loss from dual temperature piping systems, reduces noise by acting as a vibration damper and serves as an outer shield to protect metal pipes from corrosion by atmospheric and industrial environment. Maxflex™ complies with ASTM C 534-88.
CI111
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
INSULATION
Sheet InsulationRealcoldStock No.
Description System Price$ Excl. GST
N4513FR 1.22m x 0.914m x 13 mm 20 sheets/ctn 33.47
N4519FR 1.22m x 0.914m x 19 mm 10 sheets/ctn 50.62
N4525FR 1.22m x 0.914m x 25 mm 8 sheets/ctn 68.27
1 Metre Adhesive InsulationRealcoldStock No.
Description System Price$ Excl. GST
N2491FR 1.00 m x 6 mm 1 metre length 37.64
N2493FR 1.00 m x 13 mm 1 metre length 43.15
Roll InsulationRealcoldStock No.
Description System Price$ Excl. GST
N4406FR 1.00 m x 22.0 m x 6 mm Rolls 508.62
N4413FR 1.00 m x 11.0 m x 13 mm Rolls 473.33
N4419FR 1.00 m x 7.0 m x 19 mm Rolls 428.16
N4408FR 1.00 m x 22.0 m x 6 mm Roll - Adhesive 827.97
N4415FR 1.00 m x 11.0 m x 13 mm Roll - Adhesive 567.63
Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.
SpecificationsPhysical Properties Maxflex Test Method
Cell Structure Closed Cell -
Density Ibs/ft³ (g/cm³) 3-6 (0.048-0.096) ASTM D 1667
Thermal Conductivity BTU. in/ft² hr. °F(W/mK)
Mean Temp. -4°F (-20°C)
32°F (0°C)
75°F (24°C)
90°F (32°C)
104°F (40°C)
ASTM C177
JIS A1412
DIN 52613K-Value 0.22 0.032
0.23 0.034
0.25 0.037
0.26 0.038
0.27 0.039
Service Temperature -70°F to 257°F
-57°C to 125°C
Maxflex becomes hard at -57°C
But can be used even at -200°C
Water Vapour Permeability (kg/Pa.s.m) 0.10 perm-in (0.15 x 10-12) ASTM C 355
ASTM E96
Moisture Resistance (μ value) μ not less than 5000 DIN 52615
Water Absorption (weight %) Not more than 3% ASTM D 1056
Ozone Resistance No crack ASTM D 1171
Heat Stability (% shrinkage) At 200 °F and 220 °F for 7 days
4.5 and 5.5 respectively ASTM C 534
Flammability & Smoke Density Class VO UL–94
Self-extinguishing ASTM D 635
Class 1 BS476 Part 7 1987
Class 0 BS476 Part 6 1987
Smoke density 80 ASTM-E84 (15 mm thick)
U.V Weather Resistance Excellent -
Nitrosamine Contents Not detected U.S FDA
Flexibility Excellent -
CI112
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
INSULATION
Insulation TapeRealcoldStock No.
Description System Price$ Excl. GST
N4606FR Maxflex Foam Tape
Closed cells elastomeric, black colour, one side adhesive with protective film. Used for hot and cold pipe insulation. Can be used as joint protection.
48 mm x 15 metres roll - self adhering
38.48
Electrical Insulation TapeRealcoldStock No.
Description System Price$ Excl. GST
N0185 Insulation Tape - 48 mm x 30 metres roll - self adhering Black PVC 9.89
N0186 Insulation Tape - 48 mm x 30 metres roll - self adhering White PVC 10.40
N0187 Insulation Tape - 48 mm x 30 metres roll - self adhering PVC (heavy grade) 17.34
N0420 Electrical Tape 19 mm x 20 metres Black 1.68
N0421 Electrical Tape 19 mm x 20 metres Red 1.68
N0422 Hellerman Electrical Tape 19 mm x 20 metres Yellow 1.68
N0423 Electrical Tape 19 mm x 20 metres Blue 1.68
N0424 Hellerman Electrical Tape 19 mm x 20 metres Green 1.68
Duct TapeRealcoldStock No.
Description System Price$ Excl. GST
N0402 Aluminium Duct Tape - 51 mm x 45.72 metres roll 18.41
N0404 Silver Duct Tape - 51 mm x 54.86 metres roll 18.41
Petroleum TapeRealcoldStock No.
Description System Price$ Excl. GST
N0406 Denso Tape 50 mm x 10 metres roll 15.25
N0407 Denso Tape 100 mm x 10 metres roll 25.45
Note: Maxflex products complies to standard AS/ANZS 1530.30:1999.
CI113
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
INSULATION
Accessories, Sealing, Jointing CompoundsRealcoldStock No.
Description Sold Per System Price$ Excl. GST
Insulation Adhesive
N0180 Virginia KMP Adhesive for tube insulation. 236ml Tin 26.27
N0170 Holdfast H2 Insulation Adhesive for tube insulation. 125ml Tin 15.56
N0172 Holdfast H2 Insulation Adhesive for tube insulation. 250ml Tin 20.50
Sealing Compounds
N0512 Holdfast Bison Silicone Sealant (White) 375ml Tube 21.47
N0515 Holdfast Fix all 220 Sealant White 425g Tube 27.34
N0519 Holdfast Silaseal Silicone Sealant (Clear) 310ml Tube 23.56
N0190 Holdfast Nailpower FR Expanding Foam 750ml Aerosol Can 47.28
N0191 Holdfast Foam Cleaner 500ml Aerosol Can 25.25
N0192 Holdfast Spare Nozzle Pack of 4 5.25 per pack
Polyurethane Foam
N0197 Endurathane is a low density, flame retardant, rigid polyurethane foam system kit, consisting of 1kg tin of each component ‘A’ and ‘B’. When mixed together at optimum temperature, will yield a total of approximately 56.6 litres (0.057m³).
2 X 1Kg Tins A + B
96.70
N0198 Endurathane (as above) 2 x 5kg components. Will yield 283 litres (0.28m³)
2 X 5Kg Tins A +B
327.42
Thermal Mastic
N0020 Presstite Thermal Mastic 3.8 Litre Tin 90.37
N0021 Presstite Thermal Mastic 225gm Tube 20.50
Note: A heat conducting compound - increases heat transfer at four times the rate obtained with mechanical mounting.
Insulation Mastic
N0025 Virginia PM11 Insulation Mastic
Weatherproof, stops surface condensation, reduces heat transfer & conductivity
3.8 Litre Tin 128.00
Dektite Pipe Flashing - Square BaseDektite provides a durable maintenance-free seal, no matter what profile or diameter pipe
RealcoldStock No.
Model Description Sold Per System Price$ Excl. GST
N0500 DB0-35 Mini Dektite Ideal for cable or conduit 20 per carton, each 18.41
N0501 DB5-55 Dektite to 55 mm 10 per carton, each 20.50
N0502 DB50-70 Dektite to 70 mm 10 per carton, each 22.08
N0503 DB70-110 Dektite 50 - 120 mm 10 per carton, each 33.10
N0504 DB110-160 Dektite 110 - 170 mm 10 per carton, each 35.75
N0505 DB160-220 Dektite to 220 mm 10 per carton, each 65.18
N0506 DB220-300 Dektite 160 - 300 mm 10 per carton, each 102.46
N0521 RF801G Round Base Dektite 20 - 70 mm Retrofit: for existing and fixed piping
10 per carton, each 45.19
N0495 Top-Hat Roof penetration kit 87.55
Note: Material Safety Data Sheets are available, upon request, for hazardous substances.
N0020
N0025
N0512
N0021
N0502
CL114
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
LUBRICANTS
Compressor LubricantsRealcoldStock No.
Type Description System Price$ Excl. GST
Mineral Oil
N0531 Suniso 3GS (150 VIS) Mineral Oil - 3.8 Litre Container. Low/Medium Temp 49.64
N0535 Suniso 3GS (150 VIS) Mineral Oil - 19 Litre Container Low/Medium Temp 234.55
N0541 Suniso 4GS (300 VIS) Mineral Oil - 3.8 Litre Container Medium/High Temp 49.64
N0545 Suniso 4GS (300 VIS) Mineral Oil - 19 Litre Container Medium/High Temp 234.55
N0551 Suniso 5GS (500 VIS) Mineral Oil - 3.8 Litre container Suitable for Tecumseh CG, York F210R, Sanden. Automotive/Marine
51.89
Guide: 150 SUS 32 cST, hence Suniso 3GS (150) and Clavus G32
300 SUS 68 cST, hence Suniso 4GS (300) and Clavus G68
Polyolester Oil
N0579 Emkarate LE 32MAF Polyolester Oil - 19 Litre Low/Medium Temp 989.40
N0580 Emkarate LE 32MAF Polyolester Oil - 3.8 Litre Low/Medium Temp 240.98
N0581 Emkarate LE 32MAF Polyolester Oil - 0.95 Litre Low/Medium Temp 64.26
N0582 Emkarate RL 68H Polyolester Oil - 0.95 Litre Medium/High Temp 64.26
N0583 Emkarate RL 68H Polyolester Oil - 3.8 Litre Medium/High Temp 244.19
N0584 Emkarate RL 100S Polyolester Oil - 0.95 Litre Automotive/Marine 59.06
Vacuum Pump LubricantsThis is a specially selected oil with a low vapour pressure and high stability for sealing.
RealcoldStock No.
Type Description System Price$ Excl. GST
N0105 Yellow Jacket Vacuum Pump Oil - .47L 13.28
N0106 Yellow Jacket Vacuum Pump Oil - .95L 24.31
N0108 Yellow Jacket Vacuum Pump Oil - 3.8 L 83.33
Note: Compressor lubricants are not suitable for vacuum pumps. Material Safety Data Sheets are available, upon request, for hazardous substances.
Oil PumpRealcoldStock No.
Type Description System Price$ Excl. GST
T2162 Yellow Jacket 77940 Max-Flow Combination Suction/Discharge Pump.
Suits all containers
290.24
T2164 Yellow Jacket 77930 Max Flow Deluxe Pump 352.36
T2640 Yellow Jacket 77931 O Ring Kit for Max Deluxe 20.99
Oil InjectorRealcoldStock No.
Type Description System Price$ Excl. GST
T2160 Yellow Jacket 69562 Oil Injector. 118ml (4oz) . 1/4” MF x 1/4” FF Quick Connector 215.27
Frascold OilsRealcoldStock No.
Type Description System Price$ Excl. GST
C5860 SZ-OIL1 FC300 19 Litre Oil (M/T R404) POA
C5862 SZ-OIL3 FC170 19 Litre Oil (L/T R404a) POA
C5864 SZ-OIL2 FC170 25 Litre Oil (L/T, M/T R22) POA
C5866 T00WK110 Oil Filter Kit POA
CL115
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
LUBRICANTS
Lubricants - Quick Reference ChartAshrae Number Brand Name Part Number Lubricant Type
R11 Replacement
R123 - N0541 Mineral/ Alkylbenzene Blend HCFC
R12 Replacements
R134a - N0581 P.O.E HFC
R401a Suva MP 39 N0531 Mineral/ Alkylbenzene Blend HCFC
R401b Suva MP 66 N0531 Mineral/ Alkylbenzene Blend HCFC
R401c Suva MP 52 N0531 Mineral/ Alkylbenzene Blend HCFC
R405a G2015 N0531 Mineral or Alkylbenzene PFC
R406a GHC-X3 N0531 Mineral HCFC
R409a FX 56 N0531 Mineral HCFC
R413a Isceon 49 N0581 P.O.E PFC
R414a GHG-X4 N0531 Mineral HC
R414b Hotshot N0531 Mineral HC
R502 Replacements
R409b FX 57 N0531 Mineral HCFC
R412a TP 5R N0581 P.O.E PFC
R290 Care 40 N0531 Mineral HC
R507 AZ 50 N0581 P.O.E HFC
R402a HP 80 N0531 Mineral/ Alkylbenzene Blend HCFC
R402b HP 81 N0531 Mineral/ Alkylbenzene Blend HCFC
R403a 69S (RX) N0581 P.O.E PFC
R403b 69L (RX1) N0581 P.O.E PFC
R404a HP 62 N0581 P.O.E HFC
R407a Klea 60 N0581 P.O.E HFC
R407b Klea 61 N0581 P.O.E HFC
R408a FX 10 N0531 Mineral HCFC
R411b G2018B N0531 Mineral HC
R509a TP5R2 N0581 P.O.E PFC
R22 Replacements
R407c Forane 407c N0581 P.O.E HFC
R410a AZ 20 N0581 P.O.E HFC
M059 Isceon 59 - R417a Mineral/ P.O.E/ Alkylbenzene HC
M099 Isceon 99 - R438a Mineral/ P.O.E/ Alkylbenzene HCFC
Hydrochlorofluorocarbon = HCFC
Hydrofluorocarbon = HFC
Perfluorocarbon = PFC
Hydrocarbon = HC
CO116
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
OIL CONTROL SYSTEMS
Trax Oil Control SystemsRealcoldStock No.
Description System Price$ Excl. GST
F0092 TRAX TR3201 Oil Level Control System 540.86
Oil Reservoir And AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
F0052 Henry S-9130 Adjustable Oil Level Regulator with 3/8” MF SAE equalisation connection 90 psi max. differential. Replaces S9191, S9131, S9134, S9133, S9190, & S9193
532.29
F0053 A C & R S-9108 Oil Reservoir (4 US gallon capacity) 15 litres
The oil reservoir is the holding vessel for stand-by oil necessary for the operation of the oil control system.
712.22
F0055 A C & R S-9109 Oil Reservoir (2 US gallon capacity) 7.5 litres 3/8 Flare Rotalock Valve
525.86
F0057 Henry S-9104 Reservoir Pressure Valve 3/8 Flare Connections
This valve will maintain a 5lb. positive pressure differential at the oil reservoir over the crankcase pressure ensuring an adequate oil supply to the oil level regulator.
115.67
F0062 Henry S-9104H High Pressure Check Reservoir Valve
Some parallel compressor systems have a satellite compressor which maintains a higher suction pressure than the other compressor system. The S-9104H provides a 20 lb positive pressure in the oil reservoir for this application.
115.67
F0058 Henry S-9241 Oil Level Regulator Shut-Off Valve 3/8 MF x 3/8 FF Swivel Connection S-9106-vertical mount
This valve allows each oil level regulator to be isolated if service is required on a compressor. Vertical model. For equalization lines on S-9130 regulator.
83.33
F0060 Henry 3/033/212 Sight Glass Adaptor 3 bolt 1.7/8 to suit Copeland 8R Series, Frascold W Series
153.15
F0059 A C & R S-9105 Oil Line Strainer 3/8 MF Flare- 100 Mesh 11 sq in.
This strainer protects the oil level regulator by removing foreign matter. The strainers mesh screen provides adequate straining with low pressure drop.
87.18
F0063 Rotolock Valve 3/8 - To suit A C & R reservoirs 45.26
F0066 *Henry S-4005 POE Oil Filter Drier 3/8” MF. 6 micron filtration
Removes foreign material from the oil as it passes through the filter.
255.97
F0067 Henry S-9106H Horizontal Shut-Off Valve
3/8” MF x 3/8” FF, swivel connection. Horizontal model for use where space is limited.
83.33
* Note S-4005 oil filter drier must be fitted between oil separator and crankcase, or between oil separator and reservoir on multiple compressor systems
Oil Control AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
SP2600 Sporlan OF-303 Oil Filter 3/8" Flare 291.31
SP2601 Sporlan OF-303-BP Oil Filter W/Bypass 3/8" Flare 317.02
SP2650 Sporlan S-OL Oil Sight Glass 968013 39.73
F0052
F0059
F0067
F0058
F0057/62
F0053/5
F0066
CO117
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
OIL SEPARATORS
Carly TurboilRealcoldStock No.
Model Conn. ODS Maximum Refrigerating Capacity in kW Oil Pre-Charge Litre
System Price$ Excl. GST
R134a R22 R404a
-5°C -5°C -40°C -5°C -40°C
F0400 1503S 3/8" SW ODF Solder 5 7 5 7 5 0.3 288.66
F0401 1504S 1/2" SW ODF Solder 5.5 8 6 8 6 0.3 270.30
F0402 2505 S/MMS 5/8" SW ODF Solder 17 24 17 25 17 0.3 270.30
F0404 3007 S 7/8" SW ODF Solder 25 30 24 32 26 0.3 306.00
F0406 3009 S 1 1/8" SW ODF Solder 28 36 28 40 29 0.3 319.26
F0408 3011 S/MMS 1 3/8" SW 31 45 32 47 32 0.3 337.62
F0425 8013 S 1 5/8" SW 70 90 65 94 65 1.0 639.54
F0426 9017 S 2 1/8” SW 80 110 85 120 87 1.0 703.80
F0429 FM 15021 S 2 5/8" SW 146 194 138 200 142 0.4 2,008.38
F0430 FM 30025 S 3 1/8" SW ODF Solder 318 424 303 430 310 0.4 2,107.32
F0450 Float Assembly replacement suits our F0429, F0430, CY33303450 843.54
Temperatures indicated are evaporating temperatures.
The refrigerating capacities indicated take into account a con-densing temperature of 38°C, of a 5°C superheated, of a 5°C subcooled and suction temp of 18°C.
To obtain a condensing temperature which is different to +38°C, apply the following formula:
Po = P / {T - 38) x 0.0143 + 1} (kW)
P = The refrigerating capacity of your installation (kW)
T = The condensing temperature of your installation in °C
Po = The new refrigerating capacity of your installation estimated for a condensing temperature of 38°C
CO118
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
OIL CONTROL SYSTEMS
Oil SeparatorsRealcoldStock No.
Model ODS Nominal Capacity kW * Dimensions (mm)H X D
System Price$ Excl. GST
R22 R404a
-5°C -25°C -5°C -25°C
F0869 S-5581 3/8" 4.7 3.3 4.7 3.3 210 x 102 266.22
F0070 NS-1004 1/2" 6.7 6.0 6.7 6.0 260 x 102 222.36
F0072 NS-1005 5/8” 18.6 17 18 15.8 362 x 102 225.42
F0074 NS-1007 7.8” 27.4 25.7 28.2 25 450 x 102 249.90
F0076 NS-1009 1.1/8” 35.6 33.5 36.8 32.7 533 x 102 277.44
F0078 NS-3011 1.3/8” 46 42.8 46.5 41 540 x 102 374.34
F0080 NS-3013 1.5/8” 61.6 58 63.6 57.5 472 x 153 395.76
F0882 S-5694 2.1/8” 101.7 93.8 103.6 92.5 486 x 158 604.86
Henry Helical Oil Separators/Oil ReservoirsRealcoldStock No.
Model ODS Nominal Capacity kW * Dimensions (mm)H X D
System Price$ Excl. GST
R22 R404a
-5°C -25°C -5°C -25°C
F0347 S-5392 1.5/8" 63.3 56.3 66.8 52.7 890 x 150 1,264.80
F0348 S-5394 2.1/8" 105.5 87.9 109.0 84.4 890 x 150 1,353.54
F0351 S-5302 2.1/8" 123.1 137.1 109.0 144.2 640 x 200 1,382.10
F0352 S-5303 2.5/8" 281.3 249.7 291.9 225.0 750 x 250 1,766.64
* Has removable float assembly
• All capacities shown are based on 37.8°C condensing temperature with an 18.3°C suction gas temperature.
• Dimensions are Height x Diameter in millimetres.
Replacement FloatRealcoldStock No.
Description System Price$ Excl. GST
F0330 A1900-30 Float Assembly suits S-5200 and S1900 series 470.22
F0331 2-023-001 Float Valve Gasket 8.57
AC & R Heater ElementsHeat elements add heat to oil separators to prevent migration of refrigerant to the vessel during off cycles of the compressor. Also suitable for AC & R accumulators.
RealcoldStock No.
Description System Price$ Excl. GST
F0084 S-9111 4” diameter 220 volt 25 Watt
Suits S-5520, S-5180 series oil separators
90.37
F0085 S-9112 6” diameter 220 volt 50 Watt
Suits S-5600, S-5190 series oil separators
96.14
CP119
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
High Pressure ControlsRealcoldStock No.
Model Reset Range(kPa)
Differential(kPa)
System Price$ Excl. GST
Ranco High Pressure
G0053 016-8750 Auto 690 to 3000 250 to 800 123.17
G0054 016-8751 Manual 690 to 3000 320 fixed 144.59
Differential Pressure ControlsRealcoldStock No.
Model Reset Range(kPa)
Differential(kPa)
System Price$ Excl. GST
Saginomiya
G1019 WNS-C106X Auto 50 to 350 50 to 250 190.64
PRESSURE CONTROLS
Dual Pressure ControlsRealcoldStock No.
Model Description System Price$ Excl. GST
Reset Hp/Lp Range Differential
kPa kPa
Ranco Dual Pressure Controls
G0048 017-8711* Auto
Auto
LP
HP
-30 to 700
700 to 3000
62 to 393
345 bar fixed
207.77
G0056 017-8701 Auto
Auto
LP
HP
-30 to 700
700 to 3000
62 to 393
345 bar fixed
161.72
G0055 017-8705 Auto
Manual
LP
HP
-30 to 700
700 to 3000
62 to 393
345 bar fixed
193.85
G0203 Dual Pressure Switch Replacement Cover 20.99
G0204 Single Pressure Switch Replacement Cover 20.45* These Ranco controls are complete with copper capillaries fitted. Refer to Frascold Accessories page for Sealed/Electronic Oil Protection Systems.
Saginomiya Dual Pressure Controls
G1010 DNS-D306XM Auto
Manual
LP
HP
-60 to 600
800 to 3000
60 to 400
Manual reset
141.37
G1015 DNS-D306X Auto
Auto
LP
HP
-60 to 600
800 to 3000
60 to 400
400 bar fixed
137.09
G1016 DNS-D606X* Auto
Auto
LP
HP
-60 to 600
800 to 3000
60 to 400
400 bar fixed
138.16
G1017 DNS-D606XM* Auto
Manual
LP
HP
-60 to 600
800 to 3000
60 to 400
Manual reset
141.37
* 606 series have independent contacts for high and low side.
Low Pressure ControlsRealcoldStock No.
Model Description System Price$ Excl. GST
Reset LP Range Differential
kPa kPa
Ranco Low Pressure Controls
G0044 016-8713* Auto -30 to 700 62 to 393 127.45
G0050 016-8706 Auto -30 to 700 62 to 393 123.17* These Ranco controls are complete with copper capillaries fitted.
Saginomiya Low Pressure Controls
G1000 SNS-C106X Auto -60 to 600 60 to 400 94.89
G1002 SNS-C102X Auto -20 to 200 25 to 150 94.89
G1006 SNS-C110X Auto 100 to 1000 100 to 300 94.89
CP120
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
PRESSURE CONTROLS
Pressure Control AccessoriesRealcoldStock No.
Description System Price$ Excl. GST
G0057 Ranco Angle Bracket to suit pressure controls 7.77
G0058 Shineyear Coupler (capillary and nuts) to suit pressure controls 7.71
G0060 Flica 600 mm Capillary Couplers c/w Nuts 14.35
G0062 Flica 1000 mm Capillary Couplers 16.01
Oil Protection Controls - Differential Pressure Controls (oil failure)COPD = Cut Out Pressure Differential. CIPD = Cut In Pressure Differential
RealcoldStock No.
Model Description Reset System Price$ Excl. GST
Time Delay COPD (bar) CIPD (bar)
G0096 Ranco P30-3601* 60 second 0.3 to 4 0.7 to 4.8 Manual 267.75
G0097 Ranco P30-3701* 90 second 0.3 to 4 0.7 to 4.8 Manual 293.45
G0099 Ranco P30-3801* 120 second 0.3 to 4 0.7 to 4.8 Manual 278.46
* These Ranco controls are complete with copper capillaries fitted.Please refer to Frascold Accessories page for Sealed/Electronic Oil Protection Systems.
Saginomiya Flow SwitchesRealcoldStock No.
Model Description System Price$ Excl. GST
G1090 FQS-U30G Suitable for pipes: 1” to 6”
Connection: 1” NPT
272.03
Pressure Control HosesRealcoldStock No.
Description System Price$ Excl. GST
G0070 12" Hose 1/4" FF x 1/4" FF 90° 29.24
G0071 18" Hose 1/4" FF x 1/4" FF 90° 30.37
G0072 24" Hose 1/4" FF x 1/4" FF 90° 31.49
G0074 36" Hose 1/4" FF x 1/4" FF 90° 38.07
G0075 48" Hose 1/4" FF x 1/4" FF 90° 44.72
G0076 60" Hose 1/4" FF x 1/4" FF 90° 49.64
• These hoses are designed for permanent installation and have a 1/4” FF metal to metal seat. Copper gaskets recommended. Suitable for capillary lines, etc.
• The minimum operating temperatures these hoses can be safely used at is -30°C, and the maximum is 122°C. Maximum pressure rating is 4000 kPa.
Oil Protection Controls
CP121
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
PRESSURE CONTROLS
Pressure Controls - CB Series
• Pressure Control CB series are small disc type pressure controls featuring compact structure and
proven reliability
• They are designed to suit modern designed applications with various types of connection style,
applications include air conditioning, auto industries and others.
• Type ACB - High & Medium pressure range
• Type LCB - Low pressure range
Small Pressure Controls - Type ACB, LCBRealcoldStock No.
Model OFF (PSI) ON (PSI) Colour Life Cycle (Times) System Price$ Excl. GST
G1160 LCB-PA48 6±5 21±7 Blue 10,000 56.10
G1162 LCB-PA95 10±5 25±5 Blue 10,000 56.10
G1164 LCB-PA96 35±7 60±7 Blue 10,000 56.10
G1166 ACB-PA52 150±14 225±14 Red 100,000 56.10
G1168 ACB-PA53 170±14 250±14 Red 100,000 56.10
G1170 ACB-PA55 200±20 259±10 Red 100,000 56.10
G1172 ACB-PB51 410±14 335±14 Black 100,000 56.10
G1174 ACB-PB52 385±14 310±14 Red 100,000 56.10
G1176 ACB-PB111 400±14 300±21 Red 100,000 56.10
G1178 ACB-PB112M 400±28 <300 Manual Red 10,000 81.96
G1180 ACB-PB113 350±10 250±20 Red 100,000 56.10
Conversion Factor: 1 Bar = 14.5 PSI
Electrical RatingsType ACB, LCB Category Of Ratings
M Rating
Rated Voltage (V)Rated Amps. (A)
Power Factor(COSΦ)
125V AC 250V AC 12V DC
Non-Inductive Current 1 1 to 6 1 to 4 1 to 4
Inductive
Current
Full Load
Locked Rotor
0.75
0.45
1 to 24 1 to 16 -Type ACB, LCB
↑: Operating direction on press.
Increase at high press.
M↓: Operating direction on manual reset
Contact Style Connections
Specifications
• Lead wire end: Free
• Contact action: SPST
• Ambient Temperature: -30°C to +100°C
• Fluid Temperature: -54°C to +135°C
Should mark pressure ON/OFF setting on the body
• Pressure Connection: ¼” Female
• Construction: Waterproof
Dimensions
CR122
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
REFRIGERANT
RefrigerantRealcoldStock No.
Product Description Charge Size/ Packaging System Price$ Excl. GST
L0100 R134a Household and commercial refrigeration, automotive, air conditioning and centrafugal water chillers.
Liquid or Vapour 13.5 Kg DAC POA
L0159 Isceon MO59
(R417A)
An easy to use non-ozone depleating retrofit replacement for R22 in DX AC and medium temp commercial refrigeration systems.
Liquid only 11.35 Kg DAC POA
L0199 Isceon MO99 An easy to use non-ozone depleating retrofit replacement for R22 in DX water chillers and industrial/ process cooling applications. No oil change required.
Liquid or Vapour 11.35 Kg POA
L0141 R404a Suitable for LT and MT. Liquid only 10.9 Kg DAC POA
L0145 R507 Low Temperature Refrigerant Liquid only 11.3 Kg DAC POA
L0030 R22* Suitable for A/C, MT and HT. Liquid or Vapour 13.5 Kg DAC POA
L0157 R407c Larger commercial air conditioning systems. Replacement for HCFC 22.
Liquid Only 11.3 Kg DAC POA
L0161 R410a Small to medium commercial air conditioning systems. Alternative to R22 in new equipment.
Liquid Only 11.3 Kg DAC POA
* Note: HCFC refrigerants will be phased out by 2015 in accordance to the Ozone Layer Protection Act 1996.
Refrigerant LevyRealcoldStock No.
Description Size/ Packaging System Price$ Excl. GST
Training Levy All refrigerants per Kg 0.50
Levy All refrigerants containing CFCs or HCFCs per Kg 1.50
Recovery CylindersManufactured to DOT-400 suitable for use with R410a refrigerant
RealcoldStock No.
Description System Price$ Excl. GST
T2490M 10 Kg recovery cylinders 216.00
T2491M 20 Kg recovery cylinders 310.00
Note: Refer to page TD252 for general rules for handling flurocarbon refrigerants. Go to www.realcold.co.nz to download a copy of the MSDS sheet/s.
CR123
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
REFRIGERANT
R22
R502
R717
R744
Tem
p °C
kPA
gps
igkP
Ag
psig
kPA
gps
igkP
Ag
psig
Tem
p °F
-50
-35.
510
.5*
-19
-2.8
-59.
217
.5*
582
84.5
-58
-48
-28.
68.
4*-1
0-1
.5-5
4.3
16*
639
92.7
-54.
4-4
6-2
1.16.
2*-1
-0.1
-48.
914
.4*
700
102
-50.
8-4
4-1
33.
8*8
1.2-4
2.7
12.6
* 76
411
1-4
7.2
-42
-4.2
1.2*
192.
8-3
5.9
10.6
*83
312
1-4
3.6
-40
0.01
0.5
304.
4-2
8.3
8.4*
905
131
-40
-38
101.5
426.
1-2
0.3
6*98
114
2-3
6.4
-36
223.
554
7.8
-11.6
3.4*
1061
154
-32.
8-3
432
4.6
689.
9-2
.1 0
.6*
1145
166
-29.
2-3
250
7.2
8211
.98.
31
1234
179
-25.
6-3
063
9.1
9814
.219
.42.
613
2819
3-2
2-2
880
1211
416
.531
.54.
414
2620
7-1
8.4
-26
9113
132
19.2
44.6
6.7
1592
231
-14.
8-2
410
816
150
21.8
58.6
8.7
1638
237
-11.2
-22
126
1817
024
.773
.811
1751
254
-7.6
-20
145
2119
127
.790
.113
1870
271
-4-1
816
424
213
30.9
108
1519
9428
9-0
.4-1
619
527
236
34.3
126
1821
2430
83.
2-1
420
730
261
37.9
146
2122
5932
86.
8-1
223
133
287
41.7
168
2424
0134
810
.4-1
025
437
314
45.6
191
2825
4937
014
-828
441
343
49.8
215
3127
0339
217
.6-6
310
4537
354
.124
235
2863
415
21.2
-433
448
405
58.8
269
3930
3043
924
.8-2
361
5243
863
.629
943
3204
465
28.4
039
858
473
68.7
328
4832
8547
632
243
062
510
7438
253
3769
547
35.6
446
567
548
79.5
397
5841
8360
739
.26
504
7358
885
.343
363
4630
671
42.8
854
279
630
91.4
473
6951
1174
146
.410
584
8567
397
.751
374
5629
816
5012
622
9071
810
4.2
555
8159
0385
653
.614
668
9776
611
1.260
588
6188
897
57.2
1671
610
481
511
8.3
654
9564
8494
060
.818
769
112
866
125.
770
410
267
9298
564
.420
814
118
920
133.
575
511
071
1410
3268
2286
612
697
514
1.581
111
871
.624
917
133
1033
149.
986
812
675
.226
975
141
1093
158.
693
013
578
.828
1040
151
1155
167.
699
514
482
.430
1107
161
1219
176.
910
6515
486
3211
6516
912
8618
6.6
1130
164
89.6
3412
3017
813
5519
6.7
1203
174
93.2
3613
0018
914
2620
712
7718
596
.838
1378
200
1500
217.
713
6919
910
0.4
4014
4821
015
7722
8.9
1449
210
104
4215
2522
116
5624
0.3
1543
224
107.
644
1610
233
1738
252.
216
3023
611
1.246
1688
245
1823
264.
617
2225
011
4.8
4817
7025
719
1127
7.4
1820
264
118.
450
1855
269
2001
290.
419
1427
812
252
1950
283
2095
304.
120
0529
112
5.6
5420
5029
721
9231
8.1
2110
319
129.
2
(ISCE
ON
49)
(ISCE
ON
59)
(ISCE
ON
69L
)(IS
CEO
N 7
9)
R134
AR4
06A
R409
AR4
13A
R407
CR4
10A
R417
AR4
04A
R507
R408
AR4
03B
R422
ATe
mp
°CkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
g-5
0-7
1-5
09
-25
-23
-12
-23
1-4
8-6
7-4
521
-18
-15
-3-1
712
-46
-63
-39
33-1
1-6
7-8
24-4
4-5
9-3
346
-24
171
35-4
2-5
4-2
717
617
1528
1147
-40
-43
-49
-20
2976
1626
4022
6021
.4-3
8-3
7-4
3-1
241
9329
3953
3473
35.1
-36
-35
-30
-37
-455
111
3752
6746
8849
.6-3
4-2
8-2
4-3
14
6813
049
6682
6010
457
.2-3
2-2
1-1
6-2
314
8115
061
8198
7411
873
.7-3
0-1
4-9
-16
2495
172
7497
114
8913
890
.9-2
8-5
0-7
3411
019
588
114
132
105
157
110.
2-2
63
92
4511
821
910
313
315
112
317
813
0.2
-24
1419
1157
128
245
119
152
171
141
199
141.2
-22
2629
2170
136
273
135
173
193
161
220
163.
3-2
039
4033
8415
630
315
319
521
618
124
318
7.4
-18
4952
4498
177
334
171
219
240
203
267
212.
9-1
659
6557
114
200
367
191
243
265
227
295
240.
5-1
472
7871
130
224
402
211
270
292
251
320
254.
9-1
286
9285
147
249
438
233
297
320
277
348
285.
2-1
010
110
710
016
527
647
725
632
635
030
538
231
6.9
-811
812
311
718
430
451
828
035
738
233
441
235
0.7
-613
514
013
420
433
456
130
539
041
536
444
638
6.5
-415
315
815
222
636
560
733
242
445
039
648
340
5.1
-217
217
717
224
839
865
436
046
048
643
052
044
4.4
019
219
719
227
244
070
438
949
852
546
556
048
5.7
221
121
721
429
750
075
742
053
756
550
260
352
9.2
422
924
023
732
352
981
245
257
960
854
164
457
5.3
625
326
326
235
056
686
948
562
365
258
268
959
9.4
828
328
728
737
960
493
052
066
969
862
573
264
910
313
313
314
409
645
993
557
716
747
670
783
709.
712
342
340
342
441
688
1059
595
766
798
716
831
795.
114
372
368
372
474
732
1128
635
819
851
765
886
854.
416
403
397
404
508
779
1200
676
873
906
816
942
884.
718
436
428
437
544
828
1275
719
929
964
869
998
947.
420
469
461
471
582
880
1353
764
989
1024
920
1057
1013
.522
507
495
507
621
934
1435
811
1049
1087
980
1113
1083
.124
544
530
545
662
990
1520
859
1119
1152
1040
1179
1154
.826
584
567
585
705
1049
1608
910
1179
1221
1100
1244
1192
.728
626
605
626
750
1110
1701
962
1249
1291
1170
1313
1269
.130
668
645
670
796
1175
1797
1016
1329
1365
1240
1388
1349
.832
715
687
715
844
1242
1896
1073
1399
1442
1310
1462
1433
.834
761
730
762
895
1311
2000
1131
1479
1521
1380
1540
1521
.336
811
775
811
947
1384
2108
1192
1559
1604
1460
1620
1566
.838
863
822
863
1001
1460
2220
1254
1639
1689
1530
1700
1659
.840
915
871
920
1057
1539
2336
1319
1729
1778
1610
1784
1756
.342
972
922
970
1115
1621
2456
1386
1819
1870
1700
1872
1857
.544
1029
974
1030
1176
1707
2581
1455
1909
1966
1790
1964
1962
.346
1090
1029
1090
1238
1796
2710
1527
2009
2064
1880
2057
2016
4811
5310
8511
5013
0318
8828
4416
0121
0921
6719
7021
5121
27.6
5012
1711
4412
2013
7019
8529
8316
7722
0922
7320
6022
5022
43.4
5212
8712
0412
9014
4020
8531
2617
5623
1923
8221
6023
5823
6454
1356
1267
1360
1512
2188
3274
1837
2429
2496
2270
2464
2488
.7
Pres
sure
Tem
per
atu
re C
hart
CR124
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
RECEIVERS
Vertical ReceiversRealcoldStock No.
Model Pump Down Capacity Kg @ 80%
Connections PRV Required Yes/No
System Price$ Excl. GST
Sweat Rotalock Valves SuppliedYes/NoR22 R134a R404a
Inlet Outlet Inlet Outlet
D0650 SFRV1 1.4 1.4 1.3 1/4” 1/4” 3/8” ODS 1” N Y POA
F0261 RLVCY15 1.4 1.4 1.3 1/4” 1/4” 3/4” 3/4” N Y POA
F0264 RLVCY30 2.8 2.8 2.4 3/8” 3/8” 3/4” 3/4” N Y POA
F0280 RLVCY40 3.8 3.8 3.3 3/8” 3/8” 3/4” 3/4” N Y POA
F0284 RLVCY60 5.5 5.5 4.9 1/2” 1/2” 1” 1” N Y POA
F0292 RLVCY120M 11.0 11.0 9.8 5/8” 5/8” 1 1/4” 1 1/4” N Y POA
Carly Receivers have fittings for Rotalock valves. Also the same connection allows for a solder connection as above. Gaskets are 3/4”: H1103; 1”: H1104. Mounting is by single M10 stud (F0261-F0280) or M12 (F0284).
Pressure Relief Devices
The requirements for the installation of pressure valves into pressure vessels are proscribed within AS/NZS1677.2.1998 and its amendments.
Viz;
1. Vessels of less than 300L internal gross volume:
• Vessels containing more than 1.5kg of Group B2 refrigerants: or
• 1.0 Kg of Group A3 refrigerants must be fitted with 1 or more mechanical pressure relief devices.
2. Vessels of greater than 300 L internal gross volume:
• Pressure vessels which may contain liquid refrigerant and which may be shut off from other parts of the refrigeration system shall be protected by means of two pressure relief valves.
• If the vessel is on the high pressure side of the system, the pressure relief valves shall be controlled by a changeover device.
Steelfort
CR125
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
RECEIVERS
Horizontal Receivers - Heavy Duty / Large CapacityRealcoldStock No.
Description Pump Down Capacity Kg @ 80%
Connections Dimensions (mm) System Price$ Excl. GST
Inlet Outlet Diameter LengthR134a R22 R404a
C5770 2010TV 33 28 33 1.1/4 SPUD 1.1/4 SPUD 219 1210 POA
C5780 2510TV 55 47 54 1.3/4 SPUD 1.1/4 SPUD 273 1260 POA
C5785 2515TV 81 70 80 1.3/4 SPUD 1.3/4 SPUD 273 1760 POA
C5790 2520TV 107 91 105 1.3/4 SPUD 1.3/4 SPUD 273 2260 POA
C5791 *LR2530 161 160 140 1 3/8” copper 7/8” copper 273 3084.4 POA
C5792 *LR3015 118 117 100 1 3/8” copper 1 1/8” copper 324 1584.4 POA
C5793 *LR3020 154 153 135 1 3/8” copper 1 1/8” copper 324 2084.4 POA
C5794 *LR3520 183 181 160 1 3/8” copper 1 1/8” copper 356 2084.4 POA
C5795 *LR3530 266 264 230 1 3/8” copper 1 1/8” copper 356 3084.4 POA
C5796 *LR4020 243 241 210 1 3/8” copper 1 3/8” copper 406 2084.4 POA
C5797 *LR4030 353 351 305 1 3/8” copper 1 3/8” copper 406 3084.4 POA
C5798 *LR5020 394 391 340 2 5/8” copper 2 1/8” copper 508 2148.0 POA
C5799 *LR5030 570 566 490 2 5/8” copper 2 1/8” copper 508 3146.0 POA
* Note: LR models are available on an Indent only basis, by arrangement.
• Horizontal receivers have 1/2” FNPT socket for pressure relief valve Spud fittings to suit Rotalock multi-directional valves.
• NB: Neither Rotalock nor safety valves are included in these prices. Refer to the Valves Section of this catalogue for these items.
• Capacities listed are based on receiver being 80 percent full with refrigerant temperature of 32°C.
Protection of Pressure Vessels
• All refrigeration systems, excluding self-contained low charge systems, MUST be fitted with pressure relief devices, selected for the refrigerant and operating conditions of the system.
• Relief devices must of a type that automatically reset after activation.
• Receivers that have an internal volume of 300L or more shall be protected by means of 2 pressure relief valves, controlled by a changeover device.
• High side relief to the low side has many attendant risks and the designer of such systems must ensure that the pressure of any part of the system does not exceed the maximum safe working pressure of the vessel – see AS/NZS 1677.2.1998, section 3.1 to section 3.4.
Horizontal ReceiversSteelfort
CS126
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
SIGHT GLASSES
Liquid/Moisture Indicating - CarlyRealcoldStock No.
Description System Price$ Excl. GST
H0751 Carly VCYL 12 1/4" MF 35.75
H0752 Carly VCYL 13 3/8" MF 37.84
H0753 Carly VCYL 14 1/2" MF 41.51
H0754 Carly VCYL 15 5/8" MF 48.86
H0757 Carly VCYL 22 1/4" MF 33.00
H0758 Carly VCYL 23 3/8" MF FF 39.93
H0759 Carly VCYL 24 1/2" MF FF 50.44
H0760 Carly VCYL 25 5/8" MF FF 50.44
H0763 Carly VCYL 32S 1/4" ODS 42.59
H0764 Carly VCYL 33S / MMS 3/8" ODS 44.68
H0765 Carly VCYL 34S 1/2" ODS 45.19
H0766 Carly VCYL 35S 5/8" ODS 50.44
H0767 Carly VCYL 37S 7/8" ODS 80.94
H0768 Carly VCYL 39S 1.1/8" ODS 117.30
Liquid/Moisture Indicating - SporlanRealcoldStock No.
Description System Price$ Excl. GST
SP2718 Sporlan See-All Sight Glass 5/8" ODS 49.11
SP2722 Sporlan See-All Sight Glass 7/8" ODS 71.17
SP2723 Sporlan See-All Sight Glass 1.1/8" ODS 78.34
SP2724 Sporlan See-All Sight Glass 1.3/8" ODS 155.30
SP2728 Sporlan See All Sight Glass SA-217 2.1/8” ODS 224.91
SP2700 Sporlan See-All Sight Glass 1/4" MF 34.76
SP2703 Sporlan See-All Sight Glass 3/8" MF 37.00
SP2710 Sporlan See-All Sight Glass 1/2" MF 46.38
SP2717 Sporlan See All Sight Glass 5/8" MF 48.04
SP2701 Sporlan See-All Sight Glass 1/4" MF FF 36.41
SP2704 Sporlan See-All Sight Glass 3/8" MF FF 38.61
SP2711 Sporlan See-All Sight Glass 1/2" MF FF 47.45
SP2709 Sporlan See-All Sight Glass 5/8” MF FF 56.28
SP2702 Sporlan See-All Sight Glass 1/4" ODS 36.41
SP2705 Sporlan See-All Sight Glass 3/8" ODS 38.61
SP2712 Sporlan See-All Sight Glass 1/2" ODS 48.04
Sight Glasses For Soldering On To PipeRealcoldStock No.
Description System Price$ Excl. GST
H0770 Carly VCYLS 11 1.3/8" SW 59.36
H0771 Carly VCYLS 13 1.5/8" SW 62.02
H0772 Carly VCYLS 17 2.1/8" SW 67.27
H0773 Carly VCYLS 21 2.5/8" SW 67.78
* Note: Listed sight glasses are suitable for all refrigerants except ammonia refrigeration systems. For Ammonia compatible sight glasses, please refer to page IN180.
H0751, H0752, H0753, H0754
H0758, H0759, H0760
H0764, H0765, H0766
H0770, H0771,
H0772, H0773
H0767, H0768
CT127
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TEST EQUIPMENT
Service Manifold SetsMastercool introduces the most advanced and user friendly Digital Manifold on the market today. This manifold offers a large, easy to read LCD that displays Pressures, Saturated Temperatures, Actual Temperatures, Superheat and Subcooling Temperatures for over 60 refrigerants. When used with the clamp-on thermocouple connector, it will display the actual temperature and automatically calculate the superheat or subcool temperature. When the vacuum sensor cable is attached to the manifold it will display deep vacuum. To insure lasting performance and durability the manifold case is constructed of ABS material and protected by a rugged rubber boot.The technician now has a fully functional manifold with the intelligence to quickly access and deliver the accurate information needed to do the job right.
RealcoldStock No.
Model Description Gauges / Hoses Scale System Price$ Excl. GST
Aluminium 4-Way Manifold Gauge Sets
T4110 96203-MB 4W Ball Valve Manifold (80 mm) R22, R134a, R404a bar & psi, °C 390.00
T4111 96203-EB 4W Ball Valve Manifold (80 mm) R22, R404a, R410a bar & psi, °C 390.00
Full 3/8” bore through the block increases; flow considerably, faster charging & recovery. Ball valve rotates 90° between two teflon washers requiring little effort to turn, even under pressure. Opens and closes quickly with only a quarter turn. Knob position shows whether valves are open or closed.
2-Way Aluminium Manifold Piston Valve
T2182M 93103-E 2W Aluminium Manifold R22, R404a, R410a bar & psi, °C 285.00
Mastercool’s 2-Way Manifolds feature free floating piston valve design resulting in less wear and tear in comparison to market standard twisting piston valves. Double O-Ring allows for a much better seal resulting in less leaks.
2-Way Digital Manifold
T2191M 99661 Digital 2W manifold + thermocouple, 3-150 cm
R22, R134a, R404a, R410a
bar & psi, °C, °F, Mpa, Kg/cm²
900.00
Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm hoses, vacuum sensor with cable and clamp-on thermocouple.
4-Way Digital Manifold
T2192M 99961-EU Digital 4 Way Manifold, complete set, 3-150 cm
R22, R134a, R404a, R410a
bar & psi, °C, °F, Mpa, Kg/cm2
1,480.69
T4220 99972 Digital 4W Manifold + thermocouples, 3-180 cm
R22, R134a, R404a, R410a
bar & psi, °C, °F, Mpa, Kg/cm²
1,100.00
Complete Kit in a blow molded case includes: manifold with a set of 3-150 cm (3-180 cm) ball valve hoses with manual shut-off valves and one black vacuum hose, vacuum sensor with cable, clamp-on thermocouple, data logger CD and USB cable.
Charging Hoses - Suitable for all CFCs, HCFCs, HFCs & R401aMastercool uses only GRADE 5 HOSE with a selection of Standard and Nylon Barrier for high pressure applications. Knurled brass nuts make finger tightening easy. Crimped with 8 segment dies for secure fit and maximum durability. Hoses are available in sets and a variety of lengths to meet all EPA, SAE and UL requirements for containment of refrigerant.
RealcoldStock No.
Model Description System Price$ Excl. GST
80 mm Standard Gauge
T2240M 47363 Red 90 cm HD 1/4” Hose, nylon barrier 34.17
T2242M 47361 Blue 90 cm HD 1/4” Hose, nylon barrier 34.17
T2244M 47362 Yellow 90 cm HD 1/4” Hose, nylon barrier 34.17
T2246M 47603 Charging hose red, nylon barrier WP 56 bar, L 150 cm 45.19
T2248M 47601 Charging hose red, nylon barrier WP 56 bar, L 150 cm 45.19
T2250M 47722 Charging hose yellow, HD 1/4”, L 180 cm 45.19
T2254M 47721 Charging hose blue, HD 1/4”, L 180 cm 52.02
T2259M 94160 Charging hose black Full Flow 3/8”, L 150 cm 90.37
T2277M 49603-J Charging hose red L244 - 1/2”20 UNF 47.28
T2278M 49601-J Charging hose blue L244 - 1/2”20 UNF 47.28
T2280M 46372 Set of 3-180 cm HD 1/4” hose + automatic shut-off valve 127.50
Charging Hoses
CT128
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TEST EQUIPMENT ACCESSORIES
GaugesRealcoldStock No.
Model Description Suitable for Refrigerants
Scale System Price$ Excl. GST
80 mm Standard Gauge
T2217M EBH High Pressure Gauge (80 mm) R22, R404a, R410a bar & psi, °C 52.53
T2218M MRBH High Pressure Gauge (80 mm) R22, R134a, R404a bar & psi, °C 52.53
T2219M MRBL Low Pressure Gauge (80 mm) R22, R134a, R404a bar & psi, °C 52.53
T2229M EBL Low Pressure Gauge (80 mm) R22, R404a, R410a bar & psi, °C 52.53
63 mm Standard Gauge
T2222M MRH High Pressure Gauge (63 mm) R22, R134a, R404a bar & psi, °C 44.17
T2210M MRL Low Pressure Gauge (63 mm) R22, R134a, R404a bar & psi, °C 44.17
T2223M MH High Pressure Gauge (63 mm) R22, R134a, R404/7 bar, °C 44.17
Accessories
T2233M 91553-E Gauge Protection Set (80 mm) 36.77
T2234M 93553-E Gauge Protection Set (63 mm) 33.66
T2236M 98251-E Replacement Lens for (80 mm) GGE 12.09
CouplersRealcoldStock No.
Model Description Suitable for Refrigerants
Scale System Price$ Excl. GST
Airconditioning (R410A) Couplers
T2711M 90413 R410A Adapter - 1/2”20UN F swivel nut x 1/4” 44.68
Automotive (R134a) Couplers
T2307M 82834-E Service coupler HS R134a manual 1/4” FL-M x 16 mm 99.81
T2308M 82934-E Service coupler LS R134a manual 1/4” FL-M x 13 mm 99.81
Access Port Core Remover
T2290M 91496 Valve core access tool w/access port 136.68
T4050 91490 Standard Valve Core Remover/Installer 1/4” 80.00
T4060 91498 Valve core remover/installer, incl. for R410A 150.90
Imperial Kwik - Couplers
T0092 16C Kwik-Coupler Model 16C Straight Coupler (45° Flare 1/4” Female x 1/4” Male) 69.87
T0093 15140 Kwik-Coupler Model 17C 90° Coupler (45° Flare 1/4” Female x 1/4” Male) 87.77
T0093A 65155 & 65153
Gasket Set for above Kwik-Couplers 3.88
T0095 26C Kwik-Couplers Straight 5/16” 113.22
T0097 27C Kwik-Couplers 90° Coupler 5/16” 112.20
CT129
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TEST EQUIPMENT
Recovery SystemMastercool introduces its newest addition to the recovery machine lineup. Taking the reliability of the 69000 series machines, Mastercool has enhanced those features to allow for maximum recovery capacity while at the same time decreasing size and weight. The design of the new double piston compressor and cooling by the largest fan and condenser in the market makes the new 69300 series the most complete solution to your recovery needs.
RealcoldStock No.
Model Description System Price$ Excl. GST
T2380M 69300-220 TWIN TURBO Refrigerant Recovery unit 220V-50/60 Hz 2,601.00
Specifications Recovery Rate Operating Temperature Weight Dimensions in mm
1/2 Hp oil less compressor
Direct vapour up to .39 Kg/min 0 to 50 °C 11 Kg 457 (L) x 254 (W) x 356 (H)
Direct liquid up to 3.1 Kg/min
Push pull up to 8.1 Kg/min
Recovery CylindersRealcoldStock No.
Model Description System Price$ Excl. GST
T2490M 62010 12,5 L recovery cylinder tank 216.00
T2491 63010 27,2 L recovery cylinder tank 310.00
Vacuum PumpsA good quality vacuum pump is an integral tool for complete A/C service. Mastercool vacuum pumps are durable and time tested. They stand up to the most grueling conditions and will provide years of reliable service. Mastercool offers a complete selection of pumps. Regardless of your service requirements, Mastercool has a model for your application.
RealcoldStock No.
Model Description System Price$ Excl. GST
T4240 90060-220-AUS Vacuum pump 220V/50Hz 35 Ltr/min 2 stage 500.00
T2400M 90065-220 Vacuum pump 220V/50Hz 119 Ltr/min 2 stage 1,101.60
T2402M 90067-220 Vacuum Pump 220V/50Hz 178 Ltr/min 2 stage 1,269.90
Model No. of Stages
Ultimate Vacuum
Motor Pump Speed Electrical Specs Shipping Weight
Dimensions in cm
90060-220 2 25 Microns 1/6 Hp 2850 RPM 220 V/50 Hz 5.40 Kg 29.5 x 11.5 x 21.5 x 18
90065-220 2 25 Microns 1/3 Hp 1425 RPM 220 V/50 Hz 15.0 Kg 37 x 15.5 x 27.5 x 24
90067-220 2 25 Microns 1/2 Hp 1425 RPM 220 V/50 Hz 15.40 Kg 41 x 15.5 x 27.5 x 24
CT130
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TOOLS
Other Test Equipment Digitial Vacuum Gauge is packaged in blow molded case. It is a hand held unit that uses thermocouple technology. This vacuum gauge has been designed with the technician’s field environment in mind, allowing for self-calibration and a sensor that will not be damaged by small mists of oil. This unit allows for a target vacuum range (20,000 to 1 micron) to be programmed with a light sensor indicator. Now you have the freedom to continue with your other work and come back to the system once you see the indicator light signaling your target vacuum.
RealcoldStock No.
Model Description System Price$ Excl. GST
Electronic Vacuum Gauge
T2435M 98061 Electronic thermocouple vacuum gauge 591.60
Charging Equipment
T2100M 98230 Electronic charging module for 98210 & 98210-A 365.70
T2370M 98211-A Accu-Charge II - Charging Scale, programmable 727.26
Leak Detectors
T2323M 55500-220 Heated sensor electronic leak detector w/220V battery charger 1,045.50
T2326M 55500-SEN Sensor for 55500 121.38
T4210 55100 Electronic leak detector 1,010.00
Mastercool ToolsRealcoldStock No.
Model Description System Price$ Excl. GST
Tube Cutters
T4025 70027 Mini tube cutter for 1/8” to 5/8” OD tubing 25.00
T2000M 70029 Mini tube cutter for 3/8” to 1 1/8” OD tubing 49.42
T2004M 70033 Heavy duty tube cutter 1/8 to 1-1/8” OD tubes 89.30
T4020 70035 Heavy duty tube cutter 1/4 to 1-5/8” OD tubing 48.00
Tube Deburring Tool
T2089M 71685 Pencil type reamer - metal 28.41
Tube Expander Kit
T2035M 71600 Hydra-swage tube expander kit - 7 heads 3/8” - 1 1/8” 820.00
Flaring & Swaging Tools
T4000 70048 Set of 5 swaging punches 50.00
T4010 70053 Flaring and swaging kit (275) 1/8” to 3/4” 200.00
Ratchet Wrenches
T2046M 70082 Refrigeration ratchet wrench 1/4”, 3/8”, 3/16”, 5/16” sq 47.84
CT131
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TOOLS
Flaring & Swaging ToolsRealcoldStock No.
Model Brand Description System Price$ Excl. GST
T2020 60440 Yellow Jacket Flare/Swage Kit 3/16” to 3/4” OD 367.20
T2022 60210 Yellow Jacket Flaring Kit 3/16” to 5/8” OD 90.88
T2024 60270 Yellow Jacket Flare/Burnish Kit 3/16” to 5/8” OD 181.56
T2034 60461 Yellow Jacket Swage Set with Clamping Bar 3/16” to 5/8” OD 162.18
T0742 CH-806A Shine Year Flaring Tool 1/4” to 3/4” OD 160.14
T2022
CH-806A
Tube Cutter Spares - Yellow Jacket®
RealcoldStock No.
Model Description System Price$ Excl. GST
T2502 60100 Cutter Wheel for 60101, 60102, 60103 15.76
T2504 60124 Cutter Wheel for 60139 23.15
T2506 60147 Cutter Wheel for 60146 29.99
T2516 60127 Wheel Screw for 60123 (New) 2.40
T2517 60172 Handle Screw for 60139 7.45
T2526 60079 Wheel Pin & Clip for 60101, 60102, 60103 8.67
T2528 60144 Wheel Pin & Clip for 60142 4.59
T2531 60140 Screw/Retainer for 60139 11.07
T2538 60095 Reamer Screw & Washer for 60101, 60102, 60103 11.58
Tube Cutter Spares
CT132
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TOOLS
Tube Benders (lever type) RealcoldStock No.
Model Brand Description System Price$ Excl. GST
T2084 60380 Yellow Jacket for 7/8" Tube - Bending Radius 3" 528.36
T0701 CH-364-04-1/4 Shine Year for 1/4" OD tube 48.96
T0703 CH-364-06-3/8 Shine Year for 3/8" OD tube 66.30
T0704 CH-364-08-1/2 Shine Year for 1/2" OD tube 78.29
T0705 CH-364A-10-5/8 Shine Year for 5/8" OD tube 104.04
T0706 CH-364-12-3/4 Shine Year for 3/4” OD Tube 124.00
T0710 CH-367 Shine Year for 1/4”, 5/16”, 3/8” OD tube, 11/16 radius to centre, 180° bender
30.50
Bending Springs RealcoldStock No.
Model Brand Description System Price$ Excl. GST
T0001 CH-102-04 Shine Year to suit 1/4" OD tube 4.44
T0006 CH-102-05 Shine Year to suit 5/16" OD tube 4.79
T0002 CH-102-06 Shine Year to suit 3/8" OD tube 7.09
T0003 CH-102-08 Shine Year to suit 1/2" OD tube 8.26
T0004 CH-102-10 Shine Year to suit 5/8" OD tube 9.44
T0005 CH-102-12 Shine Year to suit 3/4" OD tube 10.10
Allen Key (hex key) RealcoldStock No.
Model Brand Description System Price$ Excl. GST
T2096 60710 Yellow Jacket 9 Piece Hex Key Set (fold up)
5/64”, 3/32”, 7/64”, 1/8”, 9/64”, 5/32”, 3/16”, 7/32”, 1/4”
22.08
T2098 60685 Yellow Jacket 12 Piece Hex Key Set Ball End, c/w Case
1/2”, 1/16”, 5/64”, 3/32”, 7/64”, 1/8”, 9/64”, 5/32”, 3/16”, 7/32”, 1/4”, 5/16”
79.87
CT133
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TOOLS - MISCELLANEOUS
Pinch Off ToolRealcoldStock No.
Model Description System Price$ Excl. GST
T0052 Yellow Jacket 60665 Wing Nut & Bar Style Pinch Off & Re-Rounding Tool 58.85
T0053 Shine Year CH-201 180 mm Pinch Off Pliers 16.83
Oil PumpRealcoldStock No.
Model Description System Price$ Excl. GST
T2162 Yellow Jacket 77940 Max-Flow Combination Suction/Discharge Pump. Suits all Containers.
276.42
T2164 Yellow Jacket 77930 Max-Flow Deluxe Pump 335.58
Fin CombsRealcoldStock No.
Description System Price$ Excl. GST
T0255 Wagner T-100 Kit Interchangeable Heads (4 thru 14 fpi) 28.92
T0256 Wagner Head (8 fins per inch) Orange 4.34
T0257 Wagner Head (12 fins per inch) Dark Green 4.34
T0258 Wagner Head (5 - 10 fins per inch) White 4.34
T0259 Wagner Head (11 fins per inch) Blue 4.08
T0791 CH-352 Stainless Steel Fin Comb 11.58
Oil InjectorRealcoldStock No.
Model Description System Price$ Excl. GST
T2160 Yellow Jacket 69562 Oil Injector. 118ml (4oz). 1/4” MF x 1/4” FF Quick Connector 205.02
Inspection MirrorsRealcoldStock No.
Description System Price$ Excl. GST
T0281 Spare Bulb 2.14
T0285 Inspection Mirror - Extendable 57 mm mirror 24.74
T0286 Inspection Mirror - Spare head 14.23
T1016 MA-Line 1.1/4” Round Mirror 17.34
T0053
T0285
T0255
CT134
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TOOLS / TESTING EQUIPMENT / THERMOMETERS
Miscellaneous ToolsRealcoldStock No.
Model Description System Price$ Excl. GST
T1012 MA-KVS007 Stainless Steel Pocket Knife - 2” Blade, 3” Closed 24.74
T1000 MA03200-2 Crimping Tool 15.25
T1002 MA03203-2 Deluxe Wire Stripper/Cutter 43.61
T1350 MA-DMTK K-Temp Probe 15.76
T1351 MA-FL24LED 24 LED Service Light 18.92
T1352 MA-FL72LED 72 LED Work Light 56.76
Testing EquipmentRealcoldStock No.
Model Description System Price$ Excl. GST
Temperature Test Equipment
T1314 MA-DMT123 Dual Probe Thermometer
Extra wide Temperature range from (-200°C to 1370°C) with high accuracy
363.12
T1328 MA-RT900 Hand Held Digital Thermometer
Wide Measurement range (-50°C to 200°C), never needs to be calibrated
53.60
T1332 MA-12843 Digital Anemometer 252.96
Refractometers
T1032 MA-REF401C Glycol Refractometer
Precision optical instrument designed to measure the freezing point of ethylene or propylene based cooling systems. The two Celsius non-liner scales cover -50°C to 0°C for ethylene glycol and propylene glycol. The resolution of the temperature scale is 0°C
396.78
T1033 MA-REF700 Oil Refractometer
Easy to use handheld instrument designed to accurately measure the mineral oil in polyolester (POE) lubricant during change of refrigerants
POA
MA-3200 MA-128144
MA-KVS007
MA-DMT123
MA-RT900
MA-REF700
ThermometersArthermo -40°C/+40°C dial thermometers are housed in a heavy duty nylon case with provision for bottom or back entry capillary. Can be flush or surface mounted. Can be calibrated.
RealcoldStock No.
Model Description System Price$ Excl. GST
Dial Thermometers
U0080 Realcold 60 mm dial (3000 mm capillary) 34.17U0082 Realcold 80 mm dial (3000 mm capillary) 37.33U0084 Realcold 100 mm dial (3000 mm capillary) 39.93U0091 Realcold 100 mm dial (6000 mm capillary) 52.02
Cabinet Thermometers. Thermometers have provision for recalibrationU0147 Arthermo Type 540 -40°C /+40°C 64.5 mm dial
Stainless steel case, with foot for standing & hook for hanging.
12.65
U0148 Arthermo Type 519B -40°C /+40°C 64.5 mm dial
Acrylic resin case, with hook for hanging.
6.53
CT135
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
THERMOSTATS
Domestic - RancoRealcoldStock No.
Type Application Normal °C Cold °C Warm °C System Price$ Excl. GST
Cut In Cut Out Cut Out Cut In Cut In
G0104 K50-P1125-001 Single Temp. Cabinet -9.5 - -18 - +8.5 33.20
G0110 K50-P1126-001 Freezer Cabinet -12 -18 -24 - -9.5 33.20
G0118 K50-P1127-001 Bottle Cabinet +5 - +1.5 - +12.5 33.20
G0109 VCI (K50-P1110) Single Temp. Cabinet -5 -14 -24 - +2 35.88
G0108 VF3 (K50-P1117) Freezer -18 -24 -32 - -12 48.57
G0114 VB7 (K50-P1118) Bottle Cabinet - - -3 +2 +12 43.59
G0119 VT9 (K59-L1102) Dual Temperature - - -26 +3.5 - 44.12
Commercial - RancoRealcoldStock No.
Type Range °C Differential Sensor System Price$ Excl. GST
G0125 016-6950 -35 to -7 1.7 to 12°C Coiled Capillary 130.66
G0130 016-6951 -18 to +13 1.7 to 12°C Coiled Capillary 128.52
G0135 016-6954 -5 to +25 1.7 to 12°C Coiled Capillary 130.66
G0136 016-6924 -5 to +25 1.7 to 12°C Straight Capillary Tube 131.73
G0140 016-6980 -18 to +13 1.7 to 12°C Cross Ambient Bulb 143.51
G0145 016-6981 -5 to +25 1.7 to 12°C Cross Ambient Bulb 152.08
G0148 016-6983 +10 to +40 1.7 to 12°C Cross Ambient Bulb 141.37
G0178 018-1100 0° Fixed 1/8" Ice Capillary With Bulb 195.99
G0146 Flat Mounting Bracket to suit Ranco Thermostats 7.77
• Straight and coiled capillary thermostats are used on applications where it can be guaranteed that the sensing element is always cooler than the control head. Where local sensing is required, the coiled version is used, whereas the straight version is used to sense over a longer distance eg across an evaporator coil.
• Cross Ambient Thermostats have a capillary and remote bulb. Unlike the straight or coiled capillary models, these controls sense only at the bulb. They should be used on all applications where it is possible that the control head or capillary can be at a lower temperature than the sensing bulb.
Capillary - SaginomiyaRealcoldStock No.
Type Range °C Differential Sensor System Price$ Excl. GST
G1052 XWS-C1030AGL2 Switches: 8 amps
-35 to +30°C 2 to 7°C 2 M Capillary POA
G1053 XWS-C1060AGL2 Switches: 8 amps
-5 to + 60°C 2 to 7°C 2 M Capillary POA
G1054 CNS-C114XM2 -15° to 15°C Capillary Safety Thermostat with 1m capillary. Manual Reset Fixed Differential.
POA
G1061 DTB-X178 Bottle cabinet thermostat (Skope)
Adjustable setting OFF -10°C, ON +5°C 42.02
Note: Please refer to page CD88 for Defrost Controls and to page CE100 for Electronic Controls
CT136
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
THERMOSTATS
Saginomiya Air Conditioning ThermostatsRealcoldStock No.
Type Range °C Differential Sensor System Price$ Excl. GST
G0150 VRS-C234 Q147 10 to 35°C 1.5°C fixed Room 446.25
Two stage, auto changeover, knob adjustment 2°C fixed between stages
G0151 VRS-C234Q149 10 to 35°C 1.5°C fixed Room 154.35
Two stage, auto changeover, screw driver adjustment 2°C fixed between stages
G0153 VRS-C234 Q172 10 to 35°C 1.5°C fixed Room 154.35
Two stage with auto changeover ON/OFF Switch 2°C fixed between stages
Thermostat GuardsRealcoldStock No.
Model Height Width Depth System Price$ Excl. GST
G0161 BTG-RK 162 mm 89 mm 76 mm 43.58
With Ring Base for easy installation on new or existing thermostats
G0162 TG300M 135 mm 255 mm 75 mm 68.43
With Solid Base, for new installations, or retrofitting to existing installations where the thermostat can be temporarily unscrewed from the wall, etc.
Note: Please refer to page CD88 for Defrost Controls and to page CE100 for Electronic Controls
A1 Thermostat Guards are stylish, unbreakable, and tamper-proof. A single key is provided for convenience.
Each guard comes with the guard, key, wall bracket, and four mounting screws and anchors.
Install frame on wall, hook the guard onto the frame by means of the two hooks on top, and lock.
CT137
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TUBE
Capillary Service PacksThese service packs offer a complete selection for large commercial and air conditioning units to the smallest domestic refrigeration requirements. Selection Data Information included in Pack.
RealcoldStock No.
Description System Price$ Excl. GST
G0381 SP-1 .026" ID (0.66 mm) in 3.660 metre coils 20.99
G0382 SP-2 .0315" ID (0.80 mm) in 3.660 metre coils 20.99
G0383 SP-3 .0355" ID (0.90 mm) in 3.660 metre coils 20.99
G0384 SP-4 .0435" ID (1.10 mm) in 4.270 metre coils 20.99
G0385 SP-5 .051" ID (1.30 mm) in 4.270 metre coils 20.99
G0386 SP-6 .055" ID (1.40 mm) in 3.660 metre coils 20.99
G0387 SP-7 .064" ID (1.62 mm) in 3.050 metre coils 20.99
G0388 SP-8 .070" ID (1.78 mm) in 3.660 metre coils 20.99
G0389 SP-9 .075" ID (1.90 mm) in 2.750 metre coils 20.99
G0390 SP-10 .080" ID (2.04 mm) in 3.050 metre coils 20.99
G0391 SP-11 .088" ID (2.24 mm) in 3.660 metre coils 20.99
Capillary ToolsRealcoldStock No.
Description System Price$ Excl. GST
T0165 Capillary Tube Gauge and File Set POA
T0166 Capillary Tube File Only POA
Thick Walled Hard Drawn Copper (5.8 metre lengths)Refrigeration grade, dehydrated and nitrogen purged, sealed copper tube. Manufactured in accordance with AS/NZ 1571 ASTMB 280 Refrigeration Code. Manufactured in accordance with ASTM B88 - Cleaned in accordance with ASTM B280.
RealcoldStock No.
Outside Diameter Wall Thickness SWP System Price$ Excl. GST
Inches mm Inches mm PSI kPa
H1719 3/4 19.05 0.046 1.18 665 4583 POA
H1722 7/8 22.23 0.064 1.63 795 5478 POA
H1728 1.1/8 28.58 0.072 1.83 688 4746 POA
H1735 1.3/8 34.93 0.085 2.15 660 4553 POA
H1742 1.5/8 41.28 0.102 2.6 677 4665 POA
• Soft Drawn Copper is sold per coil and Hard Drawn Copper Tube is sold in full lengths.
• Values of SWP are derived from the formula from ANSIB31 Standard Code for Pressure Piping
• The value of Maximum Stress (S) used in the calculation is 150°F (65.6°C) and is for copper in its annealed condition. For Pipe temperatures higher than 150°F (65.6°C), please contact your local Realcold branch for assistance in the selection of appropriate tube for your requirement.
• Please see Air Conditioning Catalogue for Pre-Insulated Copper Tubing. For further information on copper tube wall thickness standards; please refer to AS/NZS 1677.2 : 1998 or enquire at your local Realcold branch.
CT138
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
TUBE
Soft Drawn Copper (15.25 metre coils)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 15.25m Length Kg
System Price$ Excl. GST
Inches mm Inches mm PSI kPa
H0002 1/8 3.17 0.030 0.762 3026 20864 0.79 POA
H0004 3/16 4.76 0.030 0.762 1867 12873 1.30 POA
H0001 1/4 6.35 0.030 0.762 1350 9308 1.82 POA
H0006 5/16 7.94 0.032 0.8128 1133 7812 2.47 POA
H0009 3/8 9.53 0.032 0.8128 930 6412 3.03 POA
H0014 1/2 12.70 0.032 0.8128 686 4730 4.12 POA
H0018 5/8 15.88 0.035 0.889 598 4123 5.69 POA
H0020 3/4 19.05 0.035 0.889 498 3413 6.91 POA
H0022 7/8 22.22 0.045 1.143 545 3758 10.34 POA
Hard Drawn Copper (full lengths)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 5m Length Kg
System Price$ Excl. GST
Inches mm Inches mm PSI kPa
H0058 3/8 9.53 0.030 0.76 869 5992 0.94 POA
H0059 1/2 12.70 0.035 0.89 757 5220 1.47 POA
H0060 5/8 15.88 0.040 1.02 691 4764 2.12 POA
H0061 3/4 19.05 0.042 1.07 600 4137 2.69 POA
H0062 7/8 22.23 0.045 1.14 545 3758 3.38 POA
H0063 1.1/8 28.58 0.050 1.27 470 3241 4.87 POA
H0064 1.3/8 34.93 0.055 1.40 422 2910 6.57 POA
H0065 1.5/8 41.28 0.060 1.52 387 2668 8.48 POA
H0075 2.1/8 53.98 0.070 1.78 345 2379 13.02 POA
H0076 2.5/8 66.68 0.080 2.03 318 2193 18.44 POA
H0077 3.1/8 79.38 0.090 2.29 301 2075 24.77 POA
Note: NZS1677 stipulates the method of calculating the maximum operating pressure for air cooled refrigeration systems to be the highest.Price fluctuations are dictated daily by the London Metal Exchange (LME).
Soft Drawn Copper (18 metre coils)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 18m Length Kg
System Price$ Excl. GST
Inches mm Inches mm PSI kPa
H0034 3/8 9.5 0.032 0.81 1094 7546 3.56 POA
H0035 1/2 12.5 0.032 0.81 807 5561 4.87 POA
H0036 5/8 15.8 0.040 1.02 813 5602 7.66 POA
H0037 3/4 19 0.040 1.02 671 4628 8.33 POA
H0038 7/8 22.2 0.045 1.143 642 4425 12.17 POA
Soft Drawn Copper (15 metre coils)RealcoldStock No.
Outside Diameter Wall Thickness SWP WT per 15m Length Kg
System Price$ Excl. GST
Inches mm Inches mm PSI kPa
H0031 1/4 6.35 0.032 0.8128 1711 11796 1.89 POA
H0032 3/16 4.76 0.032 0.8128 2371 16349 1.35 POA
H0033 5/16 7.94 0.032 0.8128 1338 9226 2.43 POA
• For information on soft drawn and hard drawn copper standards, please contact your local Realcold branch, Representative or visit www.realcold.co.nz
• Pre-Insulated Copper Tubing - Please see AC31.
CV139
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Flica Thermostatic Expansion Type TMV/TMVX (adsorber charged)Wide Range: R134a - MP39 - Isceon 49 - R12 = +15°C to -30°C
R22 = +15°C to -45°C
R404a - HP80 - R407B - R507 - Isceon 69L -R502 = 0°C to -50°C
RealcoldStock No.
Model Description System Price$ Excl. GST
R134a - MP39 - R12 - Isceon 49
F1602 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29
F1604 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14
F1652 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29
F1654 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14
R22 - Isceon 59
F1606 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29
F1608 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14
F1656 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29
F1658 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14
R404a - HP80 - R407B - R507 - R502 - Isceon 69L
F1610 Flica TMV Body Internally Equalised Wide Range MF x MF 91.29
F1612 Flica TMVX Body Externally Equalised Wide Range MF x MF 109.14
F1660 Flica TMVBL Body Internally Equalised Wide Range MF x Sweat 91.29
F1662 Flica TMVXBL Body Externally Equalised Wide Range MF x Sweat 109.14
Flica Orifices (TMV/TMVX/TMVBL/TMVXBL)Nominal capacities (kW) based on 1K subcooling/1.5 bar pressure drop.
RealcoldStock No.
Model Description System Price$ Excl. GST
R134a R22 R22 R404a R404a
-5/+40°C -5/+40°C -25/+40°C -5/+40°C -25/+40°C
F1618 Flica Orifice # 0.3 0.34 0.52 0.36 0.35 0.23 21.53
F1620 Flica Orifice # 0.5 0.65 0.98 0.69 0.66 0.43 21.53
F1622 Flica Orifice # 0.7 0.90 1.35 0.94 0.94 0.61 21.53
F1624 Flica Orifice # 1.0 1.29 1.97 1.38 1.36 0.88 21.53
F1626 Flica Orifice # 1.5 2.09 3.16 2.21 2.15 1.40 21.53
F1628 Flica Orifice # 2.0 2.69 3.99 2.79 2.72 1.77 21.53
F1630 Flica Orifice # 2.5 3.78 5.75 4.02 3.93 2.56 21.53
F1632 Flica Orifice # 3.0 6.17 9.17 6.41 6.27 4.09 21.53
F1634 Flica Orifice # 3.5 8.16 12.12 8.48 8.24 5.37 21.53
F1636 Flica Orifice # 4.5 11.04 16.89 11.81 11.52 7.50 21.53
F1638 Flica Orifice # 4.75 14.92 22.27 15.58 15.17 9.88 21.53
Note: TMV/TMVX Bodies Male Flare x Male Flare Connections TMVBL/TMVXBL Bodies Male Flare x Solder Sweat Connections
Installation: Valves may be installed in any position.Specifications: Adsorber charged diaphragm operated valve of high sensitivity. Interchangeable orifice. Wide temperature range and constant superheat.Superheating: Mean static superheat 3K.Adjustment: Initially valves should be installed with the factory setting unaltered. Should adjustment be necessary, then remove the sealing cap and adjust the spindle. Right Turn (Clockwise)- Reduces flow, thus increasing superheat. Left Turn (Anticlockwise) - Increases flow, thus decreasing superheat. One turn of the adjusting spindle alters superheat setting by approximately 8 psi.
With Adsorber charge it is impossible for charge migration or reversal to occur, thereby offering the user a reliable, trouble-free valve.
TMV
TMVXBL
Flica Thermostatic Expansion Type
Flica Orifices
CV140
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Sporlan Q-Series Thermostatic Expansion Valves3/8” x 1/2” - 90º connections, flare or sweat. All OD models are forged inlet models.
RealcoldStock No.
Model Description System Price$ Excl. GST
SP0001 SQ-ODF Q Valve Body OD Internally Equalised External Strainer 98.28
SP0002 SQE-ODF Q Valve Body OD Externally Equalised External Strainer 117.30
SP0003 Q-SAE Q Valve Body MF Internally Equalised External Strainer 77.27
SP0004 QE-SAE Q Valve Body MF Externally Equalised External Strainer 96.70
SP0071 SBQ-ODF BQ Valve Body OD Internally Equalised 98.28
SP0072 SBQE-ODF BQ Valve Body OD Externally Equalised 132.60
SP0073 BQ-SAE BQ Valve Body MF Internally Equalised 76.70
SP0074 BQE-SAE BQ Valve Body MF Externally Equalised 96.70
Sporlan OrificesRealcoldStock No.
Model Description Nominal Capacity kW System Price$ Excl. GST
R404a R22 R134a
SP0010 QC-0 Orifice No. 0 Red 0.88 1.17 0.59 11.07
SP0011 QC-1 Orifice No. 1 Yellow 1.76 2.64 0.88 11.07
SP0012 QC-2 Orifice No. 2 Green 1.76 3.52 1.76 11.07
SP0013 QC-3 Orifice No. 3 Blue 3.52 5.28 3.52 11.07
SP0014 QC-4 Orifice No. 4 Pink 5.28 8.79 5.28 11.07
SP0015 QC-5 Orifice No. 5 Black 7.03 12.3 7.03 11.07
SP0016 QC-6 Orifice No. 6 White 10.6 17.6 8.79 11.07
SP0080 AAA BQ Orifice Red 0.44-0.70 0.44-1.16 0.44-0.70 31.52
SP0081 AA BQ Orifice Yellow 0.88-1.16 1.76-2.34 0.88-1.16 31.52
SP0082 A BQ Orifice Blue 1.76-3.52 2.64-5.30 1.76-3.52 31.52
SP0083 B BQ Orifice Pink 4.40-7.03 6.16-10.60 4.40-6.16 31.52
SP0084 C BQ Orifice White 7.90-10.60 11.4-19.30 7.03-10.60 31.52
Sporlan Thermostatic ElementsRealcoldStock No.
Model Description System Price$ Excl. GST
SP0020 KT-43-VC-5' TX Element R22 Commercial -25/+10°C 57.78
SP0030 KT-43-JC-5' TX Element R134a Commercial -25/+10°C 57.78
SP0040 KT-43-SC-5' TX Element R404a Commercial -25/+10°C 57.78
SP0041 KT-43-SZ-5' TX Element R404a LT -18/-40°C 57.78
SP0042 KT-43-SZP-5' TX Element R404a LT MOP -18/-40°C 57.78
SP0043 KT-43-PC-5' TV Element R507 Commercial -25/+10°C 57.78
SP0044 KT43-VZ-5' TX Element R22 LT- Q Series -18/-40°C 57.78
SP1260 KT43-FZP-5' TX Element R134a LT MOP -18/-40°C 57.78
Sporlan AccessoriesRealcoldStock No.
Model Description System Price$ Excl. GST
SP0060 791-001 Cartridge O-Ring 5.81
SP0061 184-002 Allen Wrench 8.82
SP0062 QVT-1 Q Valve Tool 198.90
SP0063 1538-000 Inlet Strainer 11.07
SP0064 3427-000 Inlet Strainer 12.65
SQ-ODF
SQE-ODF
Q-SAE
QE-SAE
CV141
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Sporlan J8 Thermostatic Expansion ValvesSuitable for all refrigerants except Ammonia and High Pressure Carbon Dioxide. Drop-in replacement for Danfoss TX Valves. Has interchangeable orifice to control capacity. Orifices also suitable for use with Danfoss T2 and TE2 Valves
RealcoldStock No.
Model Inlet Outlet Equalised MOP Bar / °C Evap / Temp Range
System Price$ Excl. GST
SP5001 TX 134A J8S-JW BODY 3/8" Flare 1/2" Solder No - -40 to +15°C 106.00
SP5002 TX 134A J8ES-JW BODY 3/8" Flare 1/2" Solder Yes - -40 to +15°C 118.00
SP5003 TX R22 J8F-VW BODY 3/8" Flare 1/2" Solder No - -40 to +15°C 106.00
SP5004 TX R22 J8EF-VW BODY 3/8" Flare 1/2" Solder Yes - -40 to +15°C 118.00
SP5005 TX 404A J8S-SW BODY 3/8" Flare 1/2" Solder No - -40 to +10°C 106.00
SP5006 TX 404A J8ES-SW BODY 3/8" Flare 1/2" Solder Yes - -40 to +10°C 118.00
SP5015 TX 134A J8F-JW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00
SP5016 TX 134A J8EF-JW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 118.00
SP5017 TX 404A J8S-VW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00
SP5018 TX 404A J8ES-VW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 118.00
SP5019 TX R22 J8F-SW BODY 3/8" Flare 1/2" Flare No - -40 to +15°C 106.00
SP5020 TX R22 J8EF-SW BODY 3/8" Flare 1/2" Flare Yes - -40 to +15°C 106.00
SP5030 TX 134A J8S-JX60 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +17°C -40 to +15°C 106.00
SP5031 TX 134A J8ES-JX60 BODY 3/8" Flare 1/2" Solder Yes 4.1 Bar +17°C -40 to +15°C 118.00
SP5032 TX R22 J8S-VX100 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +15°C -40 to +15°C 106.00
SP5033 TX R22 J8ES-VX100 BODY 3/8" Flare 1/2" Solder Yes 4.1 Bar +15°C -40 to +15°C 118.00
SP5034 TX 404A J8S-SX110 BODY 3/8" Flare 1/2" Solder No 7.6 Bar +12°C -40 to +10°C 106.00
SP5035 TX 404A J8ES-SX110 BDY 3/8" Flare 1/2" Solder Yes 7.6 Bar +12°C -40 to +10°C 118.00
SP5036 TX 404A J8S-SX35 BODY 3/8" Flare 1/2" Solder No 2.4 Bar -17°C -40 to -18°C 106.00
SP5037 TX 404A J8ES-SX35 BODY 3/8" Flare 1/2" Solder Yes 2.4 Bar -17°C -40 to -18°C 118.00
SP5038 TX 134A J8F-JX60 BODY 3/8" Flare 1/2" Solder No 4.1 Bar +17°C -40 to +15°C 106.00
SP5039 TX 134A J8EF-JX60 BODY 3/8" Flare 1/2" Flare Yes 4.1 Bar +17°C -40 to +15°C 118.00
SP5040 TX 404A J8F-SX110 BODY 3/8" Flare 1/2" Flare No 7.6 Bar +12°C -40 to +10°C 106.00
SP5041 TX 404A J8EF-SX110 BDY 3/8" Flare 1/2" Flare Yes 7.6 Bar +12°C -40 to +10°C 118.00
SP5042 TX 404A J8F-SX35 BODY 3/8" Flare 1/2" Flare No 2.4 Bar -17°C -40 to -18°C 106.00
SP5043 TX 404A J8EF-SX35 BODY 3/8" Flare 1/2" Flare Yes 2.4 Bar -17°C -40 to +15°C 118.00
SP5044 TX R22 J8F-VX100 BODY 3/8" Flare 1/2" Flare No 4.1 Bar +15°C -40 to +15°C 106.00
SP5045 TX R22 J8EF-VX100 BODY 3/8" Flare 1/2" Flare Yes 4.1 Bar +15°C -40 to +15°C 118.00
SP5007 ORIFICE JB2-0X - - - - - 21.00
SP5008 ORIFICE JB2-00 - - - - - 21.00
SP5009 ORIFICE JB2-01 - - - - - 21.00
SP5010 ORIFICE JB2-02 - - - - - 21.00
SP5011 ORIFICE JB2-03 - - - - - 21.00
SP5012 ORIFICE JB2-04 - - - - - 21.00
SP5013 ORIFICE JB2-05 - - - - - 21.00
SP5014 ORIFICE JB2-06 - - - - - 21.00
Valve Features Advantages and Benefits
• US Manufacture and Quality
• Copper Capillary 5-Times better Conductivity than Stainless Steel
• Plasma Welded rather than Laser Welded
• New design, Long-Life Diaphragm
• Copper Connections
CV142
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Cross Reference Table - J8 / T2 / TIRefrigerant Int / Ext Inlet x Outlet
Inch: 3/8” x 1/2” (inch)Parker Item Number
J8 Code MOP °C"
T2/TE2 Part No MOP °C"
TI/TIE Part No MOP °C"
Valve Configuration Sporlan Danfoss Alco
R407C Ext flare x flare 600002 J8EF-NW no 068Z3501 no - -
R407C Ext flare x flare 600003 J8EF-NX100 +17°C 068Z3517 +15°C - -
R407C Ext flare x solder 600016 J8ES-NW no 068Z3446 no - -
R407C Ext flare x solder 600017 J8ES-NX100 +17°C 068Z3447 +15°C - -
R407C Int flare x flare 600023 J8F-NW no 068Z3496 no - -
R407C Int flare x flare 600024 J8F-NX100 +17°C 068Z3516 +15°C - -
R407C Int flare x solder 600037 J8S-NW no - no - -
R407C Int flare x solder 600038 J8S-NX100 +17°C 068Z3329 +15°C - -
R134a Ext flare x flare 600000 J8EF-JW no 068Z3348 no TIE-MW no
R134a Ext flare x flare 600001 J8EF-JX60 +17°C 068Z3349 +15°C - -
R134a Ext flare x solder 600014 J8ES-JW no 068Z3385 no TISE-MW no
R134a Int flare x solder 600015 J8ES-JX60 +17°C 068Z3389 +15°C - -
R134a Int flare x flare 600021 J8F-JW no 068Z3346 no TI-MW no
R134a Int flare x flare 600022 J8F-JX60 +17°C 068Z3347 +15°C - -
R134a Int flare x solder 600035 J8S-JW no 068Z3383 no TI-SMW no
R134a Ext flare x solder 600036 J8S-JX60 +17°C 068Z3387 +15°C - -
R404A Ext flare x flare 600004 J8EF-SW no 068Z3403 no TIE-MW no
R404A Ext flare x flare 600005 J8EF-SX110 +12°C 068Z3405 +15°C - -
R404A Ext flare x flare 600006 J8EF-SX35 -17°C "068Z3409 068Z3411"
"-10°C -20°C"
- -
R404A Ext flare x solder 600018 J8ES-SW no 068Z3415 no TIS-SW no
R404A Int flare x solder 600019 J8ES-SX110 +12°C 068Z3417 +15°C - -
R404A Int flare x solder 600020 J8ES-SX35 -17°C "068Z3430 068Z3421"
"-10°C -20°C"
- -
R404A Int flare x flare 600025 J8F-SW no 068Z3400 no TI-MW no
R404A Int flare x flare 600026 J8F-SX110 +12°C 068Z3402 +15°C - -
R404A Int flare x flare 600027 J8F-SX35 -17°C "068Z3408 068Z3410"
"-10°C -20°C"
- -
R404A Int flare x solder 600039 J8S-SW no 068Z3414 no TISE-SW no
R404A Int flare x solder 600040 J8S-SX110 +12°C 068Z3416 +15°C - -
R404A Int flare x solder 600041 J8S-SX35 -17°C "068Z3429 068Z3420"
"-10°C -20°C"
- -
R22 Int flare x solder 600061 J8S-VX100 +17°C 068Z3287 +15°C - -
R22 Int flare x solder 600059 J8S-VW no 068Z3281 no TIS-HW no
R22 Ext flare x flare 600058 J8EF-VX100 +17°C 068Z3211 +15°C - -
R22 Ext flare x solder 600057 J8ES-VX100 +17°C 068Z3290 +15°C - -
R22 Int flare x flare 600054 J8F-VX100 +17°C 068Z3208 +15°C - -
R22 Int flare x flare 600053 J8F-VW no 068Z3206 no TI-HW no
R22 Ext flare x solder 600052 J8ES-VW no 068Z3284 no TISE-HW no
R22 Ext flare x flare 600051 J8EF-VW no 068Z3209 no TIE-HW no
All - J8 orifice & filter - 0X 506032 J8C-0X - 068-2002 - T1-00X -
All - J8 orifice & filter - 00 506033 J8C-00 - 068-2003 - T1-000 -
All - J8 orifice & filter - 01 506034 J8C-01 - 068-2010 - T1-001 -
All - J8 orifice & filter - 02 506035 J8C-02 - 068-2015 - T1-002 -
All - J8 orifice & filter - 03 506036 J8C-03 - 068-2006 - T1-003 -
All - J8 orifice & filter - 04 506037 J8C-04 - 068-2007 - T1-004 -
All - J8 orifice & filter - 05 506038 J8C-05 - 068-2008 - T1-005 -
All - J8 orifice & filter - 06 506039 J8C-06 - 068-2009 - T1-006 -
This information is intended only as a guide. For further information or selection assistance, please contact your local branch. Realcold accepts no liability for the information provided and any selection is the reponsibility of the purchaser / installer.
Cross Reference Table
CV143
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Sporlan S and O-Series ValvesRealcoldStock No.
Model Refrigerant Connection Charge Capacity System Price$ Excl. GST
Tons kW
SP0734 SVE-5 R22 1/2" x 7/8" OD C 5 17.5 209.10
SP0737 SVE-8 R22 5/8" x 7/8" OD C 8 28.1 209.10
SP0741 SVE-15 R22 7/8" x 1.1/8" OD C 15 52.7 229.50
SP0756 OVE-20 R22 7/8" x 1.3/8" OD BP C 20 70.3 351.90
SP0757 OVE-30 R22 1.1/8” x 1.3/8” OD BP C 30 105 351.90
SP0758 OVE-40 R22 1.1/8" x 1.3/8" OD BP C 40 140 633.42
SP0761 OVE-40-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 40 140 630.36
SP0764 OVE-55-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 55 193 630.36
SP0767 OVE-70-CP100 R22 1.1/8” x 1.3/8” OD BP CP100 70 245 630.36
SP0774 SSE-4-C R404a 1/2" x 7/8" OD C 4 13.7 209.10
SP0777 SSE-6-C R404a 5/8" x 7/8" OD C 6 20.5 209.10
SP0780 SSE-7-C R404a 5/8" x 7/8" OD C 7 23.9 209.10
SP0786 SSE-10-C R404a 5/8" x 7/8" OD C 10 34.1 229.50
SP0792 OSE-12 R404a 7/8" x 1.3/8" OD C 12 40.9 351.90
SP0803 SSE-4-Z R404a 1/2" x 7/8" OD Z 4 13.7 209.10
SP0806 SSE-4-ZP R404a 1/2" x 7/8" OD ZP 4 13.7 209.10
SP0809 SSE-6-Z R404a 5/8" x 7/8" OD Z 6 20.5 209.10
SP0812 SSE-6-ZP R404a 5/8" x 7/8" OD ZP 6 20.5 209.10
SP0814 SSE-7-Z R404a 5/8" x 7/8" OD Z 7 23.9 209.10
SP0817 SSE-7-ZP R404a 5/8" x 7/8" OD ZP 7 23.9 210.12
SP0820 SSE-10-Z R404a 7/8" x 1.1/8" OD Z 10 34.1 229.50
SP0823 SSE-10-ZP R404a 7/8" x 1.1/8" OD ZP 10 34.1 230.52
SP0839 OSE-12-Z R404a 7/8" x 1.3/8" OD BP Z 12 40.9 351.90
SP0840 OSE-12-ZP R404a 7/8" x 1.3/8" OD BP ZP 12 40.9 352.92
SP0841 OSE-21-Z R404a 1.1/8" x 1.3/8" OD BP Z 21 74 351.90
SP0842 OSE-21-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 21 74 352.92
SP0845 OSE-30-Z R404a 1.1/8" x 1.3/8" OD BP Z 30 105 630.36
SP0846 OSE-30-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 30 105 633.42
SP0847 OSE-35-Z R404a 1.1/8" x 1.3/8" OD BP Z 35 120 630.36
SP0849 OSE-35-ZP R404a 1.1/8" x 1.3/8" OD BP ZP 35 120 633.42
Sporlan TX Valve Replacement HeadsRealcoldStock No.
Description System Price$ Excl. GST
SP1202 KIT KT33-VCP100 - For R22, Commercial, MOP100. Suits P, Large O and H Series Valves 98.79
SP1220 KT83-VCP100 - For R22, Commercial, MOP100. Suits C, Small O and S Series Valves 86.19
SP1221 KT83-VC - For R22, Commercial. Suits C, Small O and S Series Valves 86.19
SP1224 KT83-SC - For R404a, Commercial. Suits C, Small O and S Series Valves 86.19
SP1225 KT83-SZ - For R404a, Low Temp. Suits C, Small O and S Series Valves 86.19
SP1234 KT83-RZP - For R507, Low Temp, MOP35. Suits C, Small O and S Series Valves 86.19
C Charge: +10/-23°C Commercial Applications.CP100 Charge: Air Conditioning MOP ChargeZ Charge: -18/-40°C Low Temperature ZP Charge: -18/-40°C M.O.P. MOP valves are normally used to prevent hunting or compressor overload, or to limit flow at start-up under lightly loaded conditions. Can be used in place of a crankcase pressure regulator (in certain applications).BP Balanced Port: Balanced port valves counteract effects of pressure drop (loss of valve efficiency) working well down to 25% rated capacity. All other valves operate to 35% of rated capacity.
Type S-Series
Type O-Series
CV144
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Sporlan Solenoid Valves (less coil)RealcoldStock No.
Model Coil Description System Price$ Excl. GST
SP1402 A3F1 MKC1 Solenoid Valve 1/4" MF 85.12
SP1405 E5S120 MKC1 Solenoid Valve 1/4" OD 85.12
SP1411 B6F1 MKC1 Solenoid Valve 3/8" MF 113.22
SP1414 E6S130 MKC1 Solenoid Valve 3/8" OD 113.22
SP1415 ME6S130 MKC1 Solenoid Valve 3/8" OD Manual Lift Version 154.02
SP1427 B10F2 MKC2 Solenoid Valve 5/8" MF 162.18
SP1430 E9S240 MKC2 Solenoid Valve 1/2" OD 136.68
SP1431 ME9S240 MKC2 Solenoid Valve 1/2" OD Manual Lift Version 178.50
SP1450 E14S250 MKC2 Solenoid Valve 5/8" OD 180.54
SP1452 ME14S250 MKC2 Solenoid Valve 5/8" OD Manual Lift Version 220.32
SP1462 E19S270 MKC2 Solenoid Valve 7/8" OD 285.60
SP1464 ME19S270 MKC2 Solenoid Valve 7/8" OD Manual Lift Version 330.48
SP1472 E25S290 MKC2 Solenoid Valve 1.1/8" OD 419.22
SP1474 ME25S290 MKC2 Solenoid Valve 1.1/8" OD Manual Lift Version 463.08
SP1827 ME35S1110 MKC1/OMKC1 Solenoid Valve 1.3/8" OD Manual Lift Version 663.00
SP1829 ME42S2130 MKC2 Solenoid Valve 1.5/8” OD Manual Lift Version 887.40
SP1800 180 180 Solenoid Pilot Control 1/4” MF
For Positive Liquid Line Shutoff see Bulletin 30-20
283.56
• The E5, E6 E9 and E14 are compact solenoids with Pilot Operated construction. They may be mounted Horizontal, Side On, or in a Vertical Line.
• The E19 and E25 are Pilot Operated solenoids. They may be mounted Horizontal, Side On, or in a Vertical Line. • All E series valves feature extended connections, for installation without disassembly, using low silver content brazing alloy.
Sporlan Solenoid CoilsRealcoldStock No.
Model Description System Price$ Excl. GST
SP1900 MKC1 Solenoid Coil 240V 50HZ 58.34
SP1901 MKC1E Solenoid Coil 240V 50HZ 58.34
SP1905 MKC2 Solenoid Coil 240V 50HZ 63.60
SP1906 MKC2E Solenoid Coil 240V 50HZ 63.60
Many more models and variations are available - just ask your Realcold representative for advice.
Refer to page AC37 for 4-way valves.
E9S240, E6S130,
E5S120
E25S290, E19S270
MKC-1, MKC-2
MKC1E
CV145
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Parker Hannifin SpA Solenoid Valves (complete with coils)Suitable for all HFC and HCFC refrigerants, in liquid, suction, or hot gas. Fluid temperature range -30°C to +105°C. All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired, plus bracket.
RealcoldStock No.
Model OrificeSize (mm)
MinimumPressure (bar)
Max Diff.Pressure (MOPD) bar
Kv (m³/hr) System Price$ Excl. GST
G0250 Parker 1/4" MF DA 3 0.0 21 0.27 85.63
G0252 Parker 1/4" ODS DA 3 0.0 21 0.27 97.21
G0254 Parker 3/8" MF DA 3 0.0 21 0.27 85.63
G0255 Parker 3/8" MF PO 8 0.1 21 1.40 120.36
G0260 Parker 3/8" ODS PO 8 0.1 21 1.40 120.36
G0265 Parker 1/2" MF PO 10 0.1 21 1.75 128.52
G0270 Parker 1/2" ODS PO 10 0.1 21 1.75 128.52
G0275 Parker 5/8" MF PO 15 0.1 21 2.65 156.06
G0280 Parker 5/8" ODS PO 15 0.1 21 2.65 172.38
G0285 Parker 3/4" ODS PO 18 0.1 21 3.15 231.54
G0290 Parker 7/8" ODS PO 18 0.1 21 3.50 231.54
G0295 Parker 1.1/8" ODS PO 18 0.1 21 3.50 290.70
G0298 Parker 1.3/8" ODS PO 25.4 0.14 21 8.80 549.78
All valves come complete with 240 volt ±10%, 50/60 Hz coil, wired.
Abbreviations: DA = Direct Acting
PO = Pilot Operated
Minimum Pressure: This is the lowest differential pressure required for the correct operation of the solenoid valve.
Maximum Pressure: This refers to the highest differential operating pressure
(MOPD): with the lowest tolerance applied on the nominal voltage-coil.
Kv = Flow Factor: Is the volume (m³/hr) which flows through the valve at a pressure drop of 1 bar across the valve at a temperature of 20°C.
Parker Hannifin SpA Solenoid Valve Spares (replacement solenoid coils)RealcoldStock No.
Model Description System Price$ Excl. GST
G0302 YE09 240 Volt 50/60 Hz 9 Watt 32.59
G0312 ZB09 240 Volt 50/60 Hz 9 Watt
(DIN 40050 = IP 65 Coil)
30.50
G0301 JB14 240 Volt 50/60 Hz 14 Watt 33.10
G0303 YB12 24 Volt DC Coil 12 Watt POA
G0307 YB19 240 Volt 50/60 Hz 11 Watt 67.78
G0310 YB09 24 Volt 50/60 Hz 9 Watt 31.52
G0313 For ZB09 Faston Connector for (G0312) (Coil DIN = IP 65) 7.96
CV146
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES - PRESSURE REGULATORS
Crankcase Pressure RegulatorsRealcoldStock No.
Model Pressure Range Size System Price$ Excl. GST
SP2003 CRO-6-0/60 0-60 psig 1/2” ODF 222.36
SP2004 CRO-6-0/60 0-60 psig 5/8” ODF 222.36
SP2009 CRO-6-30/110 30-110 psig 5/8” ODF 229.50
SP2010 CRO-6-30/110 30-110 psig 7/8” ODF 230.52
SP2012 CRO-10-0/60 0-60 psig 7/8” ODF 307.02
SP2013 CRO-10-0/60 0-60 psig 1.1/8” ODF 308.04
SP2014 CRO-10-0/60 0-60 psig 1.3/8” ODF 318.24
SP2015 CRO-10-30/110 30-110 psig 7/8” ODF 329.46
SP2016 CRO-10-30/110 30-110 psig 1-1/8” ODF 317.22
SP2017 CRO-10-30/110 30-110 psig 1-3/8” ODF 317.22
Note: See Bulletin 90-10 and 90-11 for description of operation, application, selection and specifications.
Evaporator Pressure RegulatorsRealcoldStock No.
Model Pressure Range Size System Price$ Excl. GST
SP2100 ORIT-6 0 - 50 psig 1/2” MF 276.42
SP2103 ORIT-6 0 - 50 psig 5/8” ODF 259.08
SP2104 ORIT-6 0 - 50 psig 7/8” ODF 261.12
SP2107 ORIT-6 30-100 psig 5/8” ODF 259.08
SP2109 ORIT-6 30-100 psig 7/8” ODF 261.12
SP2110 ORIT-6 30-100 psig 1.1/8” ODF 271.32
SP2114 ORIT-10 30-100 psig 7/8” ODF 370.26
SP2115 ORIT-10 30-100 psig 1.1/8” ODF 370.26
SP2116 ORIT-10 30-100 psig 1.3/8” ODF 370.26
SP2130 ORIT-10 0-50 psig 7/8” ODF 370.26
SP2132 ORIT-10 0-50 psig 1.1/8” ODF 370.26
SP2134 ORIT-10 0-50 psig 1.3/8” ODF 370.26
SP2160 SORIT-12 0-100 psig 1.1/8” OD 766.02
SP2162 SORIT-15 0-100 psig 1.3/8” OD 966.96
SP2164 SORIT-20 0-100 psig 1.5/8” OD 1,371.90
SP2204 (S) ORIT-PI-27S 0-100 psig 7/8” OD POA
SP2206 (S) ORIT-PI-29S 0-100 psig 1.1/8" OD 1,034.28
SP2214 (S) ORIT-PI-39S 0-100 psig 1.1/8" OD 1,037.34
SP2216 (S) ORIT-PI-311S 0-100 psig 1.3/8" OD 1,110.78
SP2220 (S) ORIT-PI-411S 0-100 psig 1.3/8" OD 1,110.78
SP2222 (S) ORIT-PI-413S 0-100 psig 1.5/8" OD 1,271.94
SP2224 (S) ORIT-PI-513S 0-100 psig 1.5/8" OD 1,857.42
SP2226 (S) ORIT-PI-517S 0-100 psig 2.1/8" OD 1,871.70
Note: See Bulletin 90-20 for description of operation, application, selection and specifications.
• (S) ORIT-PI’s are Evaporator Pressure Regulating Valves Piloted Internally with an Electric Shut-off option, using a MKC1 Coil - Supplied separately.
• Refer to the Realcold Technical Department for capacity ratings.
• Many more models and variations are available.
CRO-6
(S)ORIT-PI
ORIT-10
ORIT-6
CRO-10
Pressure Regulators
CV147
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Sporlan CDS ValvesThe CDS Valves are electronically operated step motor evaporator pressure regulating valves. Synchronized sig-nals to the motor provide discrete angular movement, which translates into precise linear positioning of the valve piston. Valve pistons and ports are uniquely characterised, providing superb flow resolution and performance. The CDS Valves are easily interfaced with microprocessor based controllers.
RealcoldStock No.
Model Description System Price$ Excl. GST
SP2240 CDS9 5/8” Electronic evaporator pressure regulator POA
SP2241 CDS9 7/8” Electronic evaporator pressure regulator POA
SP2242 CDS9 1 1/8” Electronic evaporator pressure regulator POA
SP2242A CDS9 1 3/8” Electronic evaporator pressure regulator POA
SP2244 CDS17 1 3/8” Electronic evaporator pressure regulator POA
SP2245 CDS17 1 5/8” Electronic evaporator pressure regulator POA
SP2246 CDS17 2 1/8” Electronic evaporator pressure regulator POA
Sporlan Hot Gas Bypass ValvesRealcoldStock No.
Model Description System Price$ Excl. GST
SP2360 ADRSE-2 1/2” ODF Hot Gas Bypass Valve 0-80 psig 250.92
Sporlan Co2 Product RangeSporlan’s growing line of products for CO2 is setting new standards for robust design and advanced technology. Contact your Realcold branch for more information.
RealcoldStock No.
Model Family MRP/MOPD Application System Price$ Excl. GST
psig bar
Electric Expansion Valves
SER 700 48 Subcritical DX, Secondary POA
SEI 620 43
Evaporator Control and Secondary Refrigerant Valves
SEI 620 43 Subcritical DX, Secondary POA
SER 700 48
SDR 620 43
CDS 700 48
Controllers, Accessories
ECM - CO2 - - Subcritical DX, Secondary POA
CO2 - Superheat - -
Kelvin CO2 - -
Temperature Sensor -40 - 210°F -40 - 100°C
Pressure Transducer 500 34
Sightglass, Filter Drier
See-All® Sightglass 650 45 Subcritical DX, Secondary POA
Catch-All® Filter Drier 650 45
Solenoid Valves E3 700/450 48/31 Subcritical DX, Secondary POA
E5S130-HP 700/450 48/31
E6S130-HP 700/450 48/31
E9S240-HP 700/450 48/31
E9S250-HP 700/450 48/31
E14S250-HP 700/450 48/31
E10S250-HP 700/450 48/31
CDS-17
CDS-9
CV148
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Mueller Ball Valves (two way)Mueller ball valves may be used on high and low pressure refrigerant lines for either gas or liquid service. Suit-able for HCFC, HFC refrigerants, and all refrigerant oils. The ball seals are carbon filled teflon. This permits higher sealing force than with virgin teflon, yet gives extended sealing life with the greater strength of the filled material. Maximum working pressure is 500 psi. Maximum temperature range -40°C to +149°C.
RealcoldStock No.
Model Description System Price$ Excl. GST
H0868 Mueller 3/8" ODS Full Port 75.12
H0869 Mueller 1/2" ODS Full Port 75.12
H0870 Mueller 5/8" ODS Full Port 78.29
H0871 Mueller 7/8" ODS Full Port 105.06
H0872 Mueller 1.1/8" ODS Full Port 155.04
H0873 Mueller 1.3/8" ODS Full Port 214.20
H0875 Mueller 1.5/8" ODS Full Port 241.74
H0876 Mueller 2.1/8" ODS Full Port 373.32
H0877 Mueller 2.5/8" ODS Reduced Port 639.54
H0878 Mueller 3.1/8" ODS Reduced Port 702.78
Mueller Liquid Receiver ValvesMaximum working pressure 500 psi. Maximum temperature rating 149°C. MP are NPT (National Pipe Thread).
RealcoldStock No.
Model Description System Price$ Excl. GST
H0951 Mueller A - 11031 1/4" MF x 1/4” MP 49.93
H0952 Mueller A - 13613 1/4” MF x 3/8” MP 63.04
H0953 Mueller A - 11030 3/8” MF x 1/4” MP 49.93
H0954 Mueller A - 13503 3/8” MF x 3/8” MP 63.04
H0955 Mueller A - 11042 1/2” MF x 3/8” MP 81.45
H0956 Mueller A - 13220 1/2” MF x 1/2” MP 96.70
H0958 Mueller A - 13183 5/8” MF x 1/2” MP 161.16
Mueller Rotalock ValvesRealcoldStock No.
Model Description System Price$ Excl. GST
H1006 1/4" Valve Flare Horizontal 3/4" R/L 66.20
H1007 3/8" Valve Sweat Horizontal 1" R/L 68.85
H1009 3/8" Valve Flare Horizontal 3/4" R/L 66.20
H1013 1/2" Valve Flare Horizontal 1" R/L 67.78
H1014 1/2" Valve OD Horizontal 1" R/L 68.85
H1017 5/8" Valve OD Horizontal 1" R/L 72.01
H1031 3/4" Valve Sweat Horizontal 1”.1/4" R/L 131.58
H1036 7/8" Valve Sweat Horizontal 1”.1/4" R/L 131.58
H1042 1.1/8" Valve Sweat Horizontal 1”.3/4" R/L 199.92
H1045 1.3/8" Valve Sweat Horizontal 1”.3/4" R/L 206.04
H1074 1.1/4" Rotalock Spud less process port 23.66
H1080 1.3/4" Rotalock Spud less process port 29.99
H1103 3/4" Teflon Fibre Seal 2.60
H1104 1" Teflon Fibre Seal 2.60
H1105 1.1/4" Teflon Fibre Seal 2.60
H1106 1.3/4" Teflon Fibre Seal 2.60
Note: Valves have top gauge connection
CV149
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Mueller Hand Shut-Off Valves (packless line valves)Mueller valves have full size openings for maximum flow with minimum restriction. The maximum working pres-sure is 500 psi with flow in direction of the arrow, and 350 psi with flow against the arrow. Working temperature range is -40°C to +90°C. All valves diaphragm type.
RealcoldStock No.
Model Description System Price$ Excl. GST
H0820 Mueller 1/4" ODS Two way straight through 124.44
H0821 Mueller 3/8" ODS Two way straight through 124.44
H0822 Mueller 1/2" ODS Two way straight through 160.14
H0823 Mueller 5/8" ODS Two way straight through 160.14
H0841 Mueller 1/4" MF Two way straight through 109.14
H0842 Mueller 3/8" MF Two way straight through 109.14
H0843 Mueller 1/2" MF Two way straight through 144.84
H0844 Mueller 5/8" MF Two way straight through 144.84
Mueller Pressure Relief ValvesValves listed are constructed and stamped with the ASME UV symbol in accordance with the requirements of the ASME and are approved by Maritime Transport - a Division of the New Zealand Ministry of Transport. The set point of the relief valve must not exceed the safe working pressure (SWP) stamped on an approved receiver.
RealcoldStock No.
Model Size Connections Pressure Settings Capacity Ratings System Price$ Excl. GST
Inlet Outlet PSI kPa Lbs Air Per Minute
G0543 Mueller A-15508-AH 1/8" MPT Atmosphere 400 3413 7.1 108.12
G0544 Mueller A-15508-AG 1/8" MPT Atmosphere 350 2578 6.3 108.12
G0545 Mueller A-15508-AE 1/8" MPT Atmosphere 300 2069 5.4 108.12
G0546 Mueller A-15509-AE 1/4" MPT Atmosphere 300 2069 5.4 108.12
G0547 Mueller A-15509-AG 1/4" MPT Atmosphere 350 2413 6.3 108.12
G0548 Mueller A-15509-AH 1/4" MPT Atmosphere 400 2578 7.1 108.12
G0559 Mueller A-15504-AE 1/2" MPT 5/8" MF 300 2069 25.4 188.70
G0565 Mueller A-15504-AG 1/2" MPT 5/8" MF 350 2413 29.5 188.70
G0567 Mueller A-15504-AH 1/2" MPT 5/8" MF 400 2578 33.5 188.70
Note: The above are National Pipe Threads 9.27
Three Way Hand Shut-Off ValvesRealcoldStock No.
Description System Price$ Excl. GST
G0580 Henry 925 Brass 1/2" FPT Dual shut off valve 222.36
G0582 Mueller Brass 1/2" FPT Dual shut off valve 354.96
• Body - Forged Steel
• Seat Discs - Steel
• Maximum Working Pressure - 400 psi (28.1 Kg/cm²)
• Maximum Temperature Rating - 115°C
Atmosphere
Straight Through
CV150
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Check Valves - Refrigerants HFC & HCFCThese valves offer minimum restriction to flow and provide a positive seal against reverse flow. They will operate in any position.
RealcoldStock No.
Model Description System Price$ Excl. GST
G0501 Mueller 1/4" Male Flare Max. working pressure 500 psi Max. Temperature +93°C
33.66
G0503 Mueller 3/8" Male Flare 38.91
G0505 Mueller 1/2" Male Flare 63.04
G0507 Mueller 5/8" Male Flare 63.04
G0490 Mueller 1/4" ODS Extended Ends 47.28
G0491 Mueller 3/8" ODS Extended Ends 49.93
G0492 Mueller 1/2" ODS Extended Ends 84.05
G0493 Mueller 5/8" ODS Extended Ends 90.37
G0509 Mueller 7/8" ODS B34235 Max. working pressure 450 psi Max. Temperature +149°C
405.96
G0510 Mueller 1.1/8" ODS B34236 “ 405.96
G0511 Mueller 1.3/8" ODS B34237 “ 659.94
G0512 Mueller 1.5/8" ODS B34238 “ 659.94
G0514 Mueller 2.1/8" ODS B34239 “ 1,125.06
Note: Reversing Valves - Please refer to page AC37.
GasketsRealcoldStock No.
Model Description System Price$ Excl. GST
G0517 Mueller 1.3/8" - 1.5/8" Gasket Suit Mueller Check Valves POA
G0518 Mueller 2.1/8" Gasket Suit Mueller Check Valves POA
Note: Mueller B342 series check valves are 4-bolt flange types for easy disassembly when brazing and can be installed vertically or horizontally. Full port construction.
CV151
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VALVES
Line Tap ValvesNeedle automatically retracts to permit unrestricted flow.
RealcoldStock No.
Description System Price$ Excl. GST
T0309 A-1 Line Tap Valve to suit 1/4”, 5/16” and 3/8” OD tube 18.36
T0310 Supco Bullet Piercing Valve for 1/4”, 5/16” and 3/8” tube 11.58T0309 T0310
T0080 T0320
T0322 T0324
T0330 T0350
T0358 T0365
T0326 T0328
Schrader Valves / Access Ports RealcoldStock No.
Description System Price$ Excl. GST
T0080 Access Port sweats into 1/4" tube or 3/8" tube 3.93
T0320 Access Port threaded 1/8" NPT 7.45
T0322 Access Port 9-way multi-fitting 1/8" through 1/2" 6.38
T0324 Access Port with 50 mm 1/4" OD copper tail 4.85
T0325 Access Valve 1/4” Flare by 5/16 OD 2.30
T0326 Access Port threaded 1/4" NPT 8.36
T0328 Access Port Tee threaded 1/8” NPT on branch, 1/4" MF on run 26.27
T0330 Access Port Tee 1/4" onto 3/8" tube 14.74
T0332 Access Port Tee 5/16 x 3/8 OD 17.55
T0350 Access Port Tee 1/4” FF Swivel Nut x 1/4" MF x 1/4” MF 27.85
T0358 Quick Seal Nut 1/4” Flare 2.30
T0360 Valve Core Remover with Core Storage Facility 35.24
T0365 Schrader Valve Core 1.02
T0370 Schrader Valve Core - Suitable for R410a 3.47
CV152
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
VIBRATION ELIMINATORS
Suitable For All HFC, HCFC RefrigerantsDesigned for installation in air conditioning and refrigeration piping to minimise transmission of vibration from the compressor or other parts of the system.
RealcoldStock No.
ODS Laying Length System Price$ Excl. GST
F0475 3/8" 210 mm 33.10
F0476 1/2" 230 mm 34.68
F0477 5/8" 247 mm 41.51
F0478 3/4" 260 mm 41.51
F0479 7/8" 292 mm 59.36
F0481 1.1/8" 332 mm 75.12
F0482 1.3/8" 380 mm 107.10
F0483 1.5/8" 435 mm 151.98
F0484 2.1/8" 510 mm 238.68
F0485 2.5/8" 609 mm 508.98
F0486 3.1/8" 686 mm 675.24
Vibration PadISO Cube is a natural rubber pad, designed to reduce vibration and noise emanating from refrigeration and air conditioning equipment. Circular design of each pad offers a suction cup effect, which eliminates the need to bolt the pad down. Standard pad is divided into 81-50 mm segments. These 50 durometer pads will withstand a load of 180 psi per each 50 mm square.
To prolong machine life, reduce maintenance cost and dampen vibration. Resists: water, aging, oil & compression set. Recommended maximum load capacity: 50 pounds per square inch.
RealcoldStock No.
Description System Price$ Excl. GST
V0265 ISO Cube Vibration Pad 8t Cubes
ISO-18 450 mm x 450 mm x 19 mm
128.52
V0290 ISO Cube Vibration Pad Single Square
50 mm x 50 mm x 19 mm
2.86
V0271 MA-Line Solid Rubber Pad 455 mm x 455 mm x 5 mm 64.11
Vibration Eliminators - Installation Hints
Install the unit as close to the compressor as possible, and at right angles to the vibration motion. Anchor the refrigerant piping at the end of the unit furthest away from the vibration source. Allow sufficient space for the unit so that it will not be subject to static compression or tension after brazing it into place. Units should be installed in a straight line; they are not intended to compensate for offset piping.
If the unit is installed in an area where condensate can accumulate on it, cover the unit with a waterproof barrier to prevent moisture from freezing under the braid and ferrules, causing the unit to rupture. Care should be taken when making the sweat connections - direct the torch flame away from the braid and clean excess flux from the unit.
For situations of severe vibration, install two units in series at right angles to one another.
Spares153
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - Medium Temperature R404aRealcoldStock No.
Description Model
C7010 AEZ4425Z
C1043 Relay MTRP0037-31
C1591 Overload MRP63AMK-3240
C2000 Capacitor 50 uf/260V
C7012 AEZ4430Z
C1045 Relay MTRP0027-31
C1504 Overload MRP56AMK-3240
C2000 Capacitor 50 uf/260V
AEZ4440Z NO COMP
C1049 Relay MTRP0030-31
C1672 Overload MST58AMN-3240
C2038 Capacitor 100 uf/260V
C7014 AEZ9440Z
C1153 Relay 3ARR3-T3AB3
C1535 Overload MSP61AMK-3242
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
AEZ4450Z NO COMP
C1027 Relay 9660-A467-158
C1587 Overload MRT28AMK-3240
C2000 Capacitor 50 uf/260V
C7016 CAE9450Z
C1154 Relay RVA4L3D
C1670 Overload MST36AMHD-3242
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C7020 CAE9460Z
C1155 Relay 3ARR3-U10AA3
C1578 Overload MST28AMK-3242
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C7021 CAE9470Z
C1154 Relay 3ARR3-UAV3
C1667 Overload MST22APK-3242
C2010 Capacitor Start 64 uf/260V
C2050 Capacitor Run 15 uf/400V
C7022 CAJ9480Z
C1210 Relay 3ARR3-U10AU3
C1581 Overload MRT24ALK-3242
C2037 Capacitor Start 88 uf/330V
C2050 Capacitor Run 15 uf/400V
RealcoldStock No.
Description Model
C7030 CAJ95102
C1145 Relay 3ARR3-U6AC3
C1675 Overload MST00ALKD-3241
C2039 Capacitor Start 100 uf/330V
C2050 Capacitor Run 15 uf/400V
C7032 CAJ95132
C1148 Relay 3ARR3T6AY3
C1651 Overload MST18AIW-3242
C2030 Capacitor Start 88 uf/260V
C2050 Capacitor Run 15 uf/400V
C7036 CAJ45172
C1125 Relay 3ARR3 T6AV3
C1680 Overload MST16AGZ-3242
C2039 Capacitor Start 100 uf/330V
C2061 Capacitor Run 17.5 uf/400V
C7038 CAJ45192
C1190 Relay 3ARR3 W10AS3
C1685 Overload CST00AHSF-3038
C2038 Capacitor Start 100 uf/260V
C2088 Capacitor Run 35 uf/400V
FH4522Z NO COMP
C1126 Relay RVA4I3R
- Overload Internal
C2042 Capacitor Start 125 uf/330V
C2085 Capacitor Run 30 uf/400V
C7040 FH4524Z
C1148 Relay 3ARR3T6AY3
- Overload Internal
C2039 Capacitor Start 100 uf/330V
C2085 Capacitor Run 30 uf/400V
C7042 FH4531Z
- Overload Internal
C2046 Capacitor Start 156 uf/330V
C2088 Capacitor Run 35 uf/400V
MRP, MRT Type MSP,MST Type
MTRP Type
3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
Spares
Spares154
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - Low Temperature R404aRealcoldStock No.
Description Model
C0532 AEZ2415Z
C1053 Relay MTRP49-31
C1504 Overload MRP56AMK-3240
C2000 Capacitor Start 50 uf/260V
C0545 CAE2417Z
C1156 Relay 3ARR3-U3AU3
C1504 Overload MRP56AMK-3240
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C0551 CAE2420Z
C1049 Relay MTRP0030-31
C1578 Overload MST28AMK-3242
C2010 Capacitor Start 64 uf/260V
C0554 CAE2424Z
C1156 Relay 3ARR3-U3AU3
C1578 Overload MST28AMK-3242
C2010 Capacitor Start 64 uf/260V
C2050 Capacitor Run 15 uf/400V
RealcoldStock No.
Description Model
C0555 CAJ2428Z
C1150 Relay 3ARR18A-101B
C1630 Overload MRT16APK-3242
C2037 Capacitor Start 88 uf/330V
C0573 CAJ2432Z
C1157 Relay 3ARR3-U10AD3
C1580 Overload MRT20ALKD-3242
C2037 Capacitor Start 88 uf/330V
C2050 Capacitor Run 15 uf/400V
C0580 CAJ2446Z
C1140 Relay 3ARR3-U10AB3
C1580 Overload MRT20ALKD-3242
C2037 Capacitor Start 88 uf/330V
C2050 Capacitor Run 15 uf/400V
C0592 CAJ2464Z
C1155 Relay 3ARR3-U10AA3
C1583 Overload MRT00AJZ-3241
C2037 Capacitor Start 88 uf/330V
C2060 Capacitor Run 20 uf/400V
C0599 FH2480Z
C1128 Relay RVA4Q3D
- Overload Internal
C2046 Capacitor Start 156/330 156uf/330V
C2070 Capacitor Run 25/400 25uf/400V
MRP, MRT Type MSP,MST Type
MTRP Type
3ARR-18 Type
9660B Type Start Capacitor
3ARR3 TypeRun Capacitor
Spares155
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - Medium/High Temperature R22RealcoldStock No.
Description Model
C0320 AEZ4425E
C1043 Relay MTRP37-31
C1591 Overload MRP63AMK-3240
C2000 Capacitor 50 uf/260V
C0325 AEZ4430E
C1080 Relay 9660-B467-138
C1504 Overload MRP56AMK-3240
C2000 Capacitor Start 50 uf/260V
C0333 AEZ4440E
C1049 Relay MTRP0030-31
C1672 Overload MST58AMN-3240
C2038 Capacitor 100 uf/260V
C0335 AEZ9440T
C1153 Relay 3ARR3U3AB3
C1535 Overload MSP61AMK-3242
C2010 Capacitor Start 64 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C0339 CAE4450E
C1049 Relay MTRP0030-31
C1578 Overload MST28AMK-3242
C2000 Capacitor 50 uf/260V
C0340 CAE9450T
C1154 Relay 3ARR3U3AV3
C1545 Overload MRT36AMHD-3242
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C0351 CAE9460T
C1154 Relay 3ARR3U3AV3
C1578 Overload MST28AMK-3242
C2000 Capacitor Start 50 uf/260V
C2005 Capacitor Run 7.5 uf/400V
C0360 CAJ9480T
C1140 Relay 3ARR3U10AB3
C1581 Overload MRT24ALKD-3242
C2039 Capacitor Start 100 uf/330V
C2050 Capacitor Run 15 uf/400V
C0375 CAJ9510T
C1140 Relay 3ARR3U10AB3
C1580 Overload MRT20ALKD-3242
C2039 Capacitor Start 100 uf/330V
C2050 Capacitor Run 15 uf/400V
RealcoldStock No.
Description Model
C0390 CAJ9513T
C1155 Relay 3ARR3U10AA3
C1585 Overload MRT00AJK-3241
C2037 Capacitor Start 88 uf/330V
C2050 Capacitor Run 15 uf/400V
C0392 CAJ4517E
C1125 Relay 3ARR3K6AV3
C1620 Overload MST00AHKE-3241
C2039 Capacitor Start 100 uf/330V
C2060 Capacitor Run 20 uf/400V
C0393 FH4522F
C1126 Relay RVA4I3R
- Overload Internal
C2042 Capacitor Start 125 uf/330V
C2085 Capacitor Run 30 uf/400V
C0394 CAH4524T
C1148 Relay 3ARRAT6AY3
- Overload Internal
C2042 Capacitor Start 125uf/330V
C2085 Capacitor Run 30uf/400V
C0395 FH4524F
C1126 Relay RVA4I3R
- Overload Internal
C2039 Capacitor Start 100 uf/330V
C2085 Capacitor Run 30 uf/400V
C0396 CAH4531E
C1125 Relay 3ARR3U4AA3
- Overload Internal
C2046 Capacitor Start 156uf/330V
C2088 Capacitor Run 35uf/400V
C0397 FH4531F
C1125 Relay 3ARR3K6AV3
- Overload Internal
C2046 Capacitor Start 156 uf/330V
C2088 Capacitor Run 35 uf/400V
MRP, MRT Type MSP,MST Type
MTRP Type
3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
Spares156
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - Options R22 (c/w start kit)RealcoldStock No.
Description Model
C0110 AJ5510F
C1190 Relay 3ARR3K10AS3
C1640 Overload MST 18AKN-3242
C2080 Capacitor Start 21 uf/330 V
C2050 Capacitor Run 15 uf/400 V
C0111 AJ5512E
C1190 Relay 3ARR3K10AS3
C1650 Overload MRT 18AJN-3242
C2080 Capacitor Start 21 uf/330 V
C2050 Capacitor Run 15 uf/400 V
C0123 AJ5513E
C1195 Relay 3ARR3K4AA3
C1651 Overload MST 18AIW-3242
C2080 Capacitor Start 21 uf/330 V
C2060 Capacitor Run 20 uf/400 V
C0124 AJ5515E
C1200 Relay 3ARR3K6AV3
C1662 Overload MRT 16AGZ-3242
C2080 Capacitor Start 21 uf/330 V
C2060 Capacitor Run 20 uf/400 V
C0126 AJ5518E
C1190 Relay 3ARR3 K10 AS3
C1663 Overload CST16AHSF-3054
C2080 Capacitor Start 21 uf/330 V
C2070 Capacitor Run 25 uf/400 V
C0127 AJ5519E
C1190 Relay 3ARR3K10AS3
C1665 Overload CST 00AHPH-3038
C2080 Capacitor Start 21 uf/330 V
C2070 Capacitor Run 25 uf/400 V
C0128 AH5524E
C1025 Relay 3ARR3U3P2
- Overload Internal
C2030 Capacitor Start 88 uf/260 V
C2088 Capacitor Run 35 uf/400 V
Electrics - Standard R22 (c/w PTC relay)RealcoldStock No.
Description Model
C0110 AJ5510F
C1011 Relay CTP9EAEQ
C1640 Overload MST 18AKN-3242
C2050 Capacitor Run 15 uf/400 V
C0111 AJ5512E
C1011 Relay CTP9EAEQ
C1650 Overload MRT 18AJN-3242
C2050 Capacitor Run 15 uf/400 V
C0123 AJ5513E
C1011 Relay CTP9EAEQ
C1651 Overload MST 18AIW-3242
C2060 Capacitor Run 20 uf/400 V
C0124 AJ5515E
C1011 Relay CTP9EAEQ
C1662 Overload MRT 16AGZ-3242
C2060 Capacitor Run 20 uf/400 V
C0126 AJ5518E
C1011 Relay CTP9EAEQ
C1663 Overload CST16AHSF3054
C2070 Capacitor Run 25 uf/400 V
C0127 AJ5519E
C1011 Relay CTP9EAEQ
C1665 Overload CST 00AHPH-3038
C2070 Capacitor Run 25 uf/400 V
C0128 AH5524E
C1011 Relay CTP9EAEQ
- Overload Internal
C2088 Capacitor Run 35 uf/400 V
MRP, MRT Type MSP,MST Type
MTRP Type
3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
Spares157
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - Medium/High Temperature R134aRealcoldStock No.
Description Model
C0504 AZ3414Y
C1010 Relay CTP MSDAI
C1527 Overload MRP390HZ-3007
C0505 AZ4419Y
C1012 Relay MTRP-0140-31
C1527 Overload MRP390HZ-3240
C2030 Capacitor Start 80 uf/260V
C0525 AEZ4430Y
C1080 Relay 9660-B467-138
C1543 Overload MRP61AMK-3240
C2000 Capacitor Start 50 uf/260V
C0535 CAE4440Y
C1047 Relay MTRP0012-31
C1523 Overload MRP380AMK-3240
C2022 Capacitor Start 72 uf/260V
C0536 CAE4448Y
C1047 Relay MTRP0012-31
C1560 Overload MRP36AMHD-3240
C2010 Capacitor Start 64 uf/260V
C0537 CAE4456Y
C1049 Relay MTRP0030-31
C1607 Overload T0691-A0
C2010 Capacitor Start 64 uf/260V
C0538 CAJ4452Y
C1205 Relay 3ARR18A-44B
C1582 Overload MRT26ALKD-3242
C2010 Capacitor Start 64 uf/260V
C0550 CAJ4461Y
C1205 Relay 3ARR18A-44B
C1581 Overload MRT24ALKD-3242
C2010 Capacitor Start 64 uf/260V
C0575 CAJ4492Y
C1160 Relay 3ARRA18A-98B
C1616 Overload MRT24AJN-3242
C2010 Capacitor Start 64 uf/260V
C0590 CAJ4511Y
C1155 Relay 3ARR3U10AA3
C1585 Overload MRT00AJK-3241
C2039 Capacitor Start 100 uf/330V
C2050 Capacitor Run 15 uf/400V
C0593 FH4518Y
C1190 Relay 3ARR3W10AS3
- Overload Internal
C2030 Capacitor Start 88 uf/260V
C2070 Capacitor Run 25 uf/400V
C0595 FH4525Y
C1125 Relay 3ARR3K6AV3
- Overload Internal
C2039 Capacitor Start 100 uf/330V
C2085 Capacitor Run 30 uf/400V
MRP, MRT Type MSP, MST Type
MTRP Type
3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
Low Temperature CompressorsRealcoldStock No.
Description Model
C0501 AZ1335Y
C1010 Relay CTP-MSDA1
C1601 Overload MRP 419HZ-3240
C0502 AZ1339Y
C1010 Relay CTP-MSDA1
C1601 Overload MRP 419HZ-3240
C0503 AEZ1358Y
C1010 Relay CTP-MSDA1
C1527 Overload MRP 390HZ-3240
C0522 AEZ2380Y
C1045 Relay MTRP0027-31
C1505 Overload MRP59AMHD-3240
C2000 Capacitor 50 uf/260 V
C0530 CAE2410Y
C1045 Relay MTRP0027-31
C1550 Overload MRT39AMHD-3240
C2000 Capacitor 50 uf/260 V
C0534 CAE2412Y
C1045 Relay MTRP0027-31
C1550 Overload MRT39AMHD-3240
C2000 Capacitor 50 uf/260 V
Spares158
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE GREENLINE COMPRESSORS
Electrics - High Temperature R12RealcoldStock No.
Description Model
C0015 AE6ZA7
C1030 Relay 9660-B467-111
C1523 Overload MRP380AMK-3240
C0018 AE5ZA9
C1040 Relay 9660-B467-125
C1523 Overload MRP380AMK-3240
C0028 CAE41ZF11
C1090 Relay 9660-B467-145
C1560 Overload MRP36AMHD-3240
C2000 Capacitor 50 uf/260 V
C0036 CAE4440A
C1100 Relay 9660-B467-149
C1556 Overload MRP36AMK-3240
C2030 Capacitor 88 uf/260 V
C0040 CAJ4452A
C1205 Relay 3ARR18A-44B
C1582 Overload MRT26ALKD-3021
C2010 Capacitor 64 uf/260 V
C0055 CAJ4461A
C1205 Relay 3ARR18A-44B
C1581 Overload MRT24ALKD-3242
C2010 Capacitor 64 uf/260 V
RealcoldStock No.
Description Model
C0074 CAJ4492A
C1160 Relay 3ARR18A-98B
C1616 Overload MRT24AJN-3242
C2010 Capacitor 64 uf/260 V
C0100 CAJ4511A
C1155 Relay 3ARR3 U10 AA3
C1610 Overload MST16 AHKE 3242
C2037 Capacitor Start 88 uf/330 V
C2050 Capacitor Run 15 uf/400 V
C0017 AZ0387A
C1010 Relay CTP MSDAI
C1508 Overload MSP390HZ-3240
C0020 AZ0411A
C1010 Relay CTP MSDAI
C1508 Overload MSP390HZ-3240
MRP, MRT Type MSP, MST Type
MTRP Type
3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
Spares159
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
L’UNITE HERMETIQUE COMPRESSORS
Electrics - Low Temperature R12RealcoldStock No.
Description Model
C0010 AEZ1336A
C1010 Relay CTP MSDA-I
C1510 Overload MRP 379HK-3240
C0012 AEZ1343A
C1010 Relay CTP MSDA-I
C1523 Overload MRP380AMK-3240
C0019 AEZ1360A
C1010 Relay CTP MSDA-I
C1523 Overload MRP380AMK-3240
C0022 CAE4ZF11
C1080 Relay 9660-B467-138
C1591 Overload MRP63AMK-3240
C2000 Capacitor 50 uf/260 V
C0024 AEZ1380A
C1070 Relay 9660-B467-131
C1540 Overload MRP304AMN-3240
C0026 CAE2410A
C1080 Relay 9660-B467-138
C1550 Overload MRT39AMHD-3240
C2000 Capacitor 50 uf/260 V
C0037 CAE2412A
C1100 Relay 9660-B467-149
C1550 Overload MRT39AMHD-3240
C2030 Capacitor 88 uf/260 V
MRP, MRT Type MSP,MST Type
MTRP Type 3ARR-18 Type
9660B Type
Start Capacitor
3ARR3 Type
Run Capacitor
RealcoldStock No.
Description Model
C0058 CAJ2T12
C1150 Relay 3ARR18A-101B
C1605 Overload T0155-C2
C2010 Capacitor 64 uf/260 V
C0060 CAJ2428L
C1150 Relay 3ARR18A-101B
C1630 Overload MRT16APK-3242
C2037 Capacitor 88 uf/330 V
C0077 CAJ2446L
C1140 Relay 3ARR3 U10AB3
C1580 Overload MRT20ALKD-3242
C2037 Capacitor Start 88 uf/330 V
C2050 Capacitor Run 15 uf/400 V
C0105 CAJ2464L
C1155 Relay 3ARR3 U10AA3
C1583 Overload MRT00AJZ-3241
C2037 Capacitor Start 88 uf/330 V
C2060 Capacitor Run 20 uf/400 V
C0011 AZ1335A
C1010 Relay CTP MSDAI
C1601 Overload MSP419HZ-3240
C0014 AZ1340A
C1010 Relay CTP MSDAI
C1601 Overload MSP419HZ-3240
C0021 AEZ2380C
C1080 Relay 9660-B467-138
C1506 Overload MRP61AMGE-3240
C2010 Capacitor 64 uf/260 V
Spares160
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSOR SPARES - FRASCOLD MK II
FRASCOLD MK II - SEMI-HERMETICRealcoldStock No.
To Suit System Price$ Excl. GST
Gasket Set
R0002 B159, B210 POA
R0011 A075, A157 POA
R0032 D213, D313, D318 POA
R0041 F416 POA
R0051 F424 POA
R0052 F524 POA
R0061 F519 POA
R0066 F728 POA
R0072 Q-Series POA
R0074 S733 POA
R0078 S739, S1039 POA
R0088 S1051 POA
R0091 S1551 POA
R0095 V1559, V2059 POA
R0105 V1571, V2071 MK2 POA
R0106 V2571 MK2 POA
R0108 V2084 POA
R0112 V3084 POA
R0115 Z25106, Z35106 POA
R0116 Z30126, Z40126 POA
R0117 Z40154, Z50154 POA
R0118 W50187, W60187 POA
R0119 W60206, W70206 POA
Piston
R0121 A075, A157 POA
R0123 A16, B159, B210 POA
R0127* F416, S733 POA
R0129 D213, D313, D318, F519, S739, S1039
POA
R0131* D213, D313, D318, F519, S739, S1039
POA
R0137* F424, F524 POA
R0144* F728, S1051, S1551 POA
R0215 F416, T28, T732 POA
R0195 F424, F524 POA
R0251 V1559, V2059 MK2 POA
R0252 V1571, V2071, Z25106, Z35106 POA
R0253 V2084, V2584, Z30126, Z40126
POA
R0254 Z40154, Z50154, W60206, W70206
POA
R0255 W50187, W60187 POA
RealcoldStock No.
To Suit System Price$ Excl. GST
Conrod
R0122 A075, A16 POA
R0124 A157 POA
R0125 B159 POA
R0128 D213, D313 POA
R0132 D318 POA
R0196 F416, F424, F519, F524 POA
R0197 F728 POA
R0262 V1559, V1571, V2059, V2071, V2084, V2584, Z25106, Z30126, Z35106, Z40126, Z40154, Z50154
POA
Piston & Conrod Assembly
R0151 A075 POA
R0152 A157 POA
R0153 A16 POA
R0154 B159 POA
R0155 B210 POA
R0156 D213, D313 POA
R0157 D318 POA
R0158 F416 POA
R0159 F519 POA
R0161 F424, F524 POA
R0162 F728 POA
R0163 S733 POA
R0164 S739, S1039 POA
R0165 S1051, S1551 POA
R0166 V1559, V2059 POA
R0167 V1571, V2071 POA
R0168 Z30126, Z40126 POA
R0169 Z40154, Z50154 POA
R0171 W50187, W60187 POA
R0172 W60206, W70206 POA
R0173 Q728 POA
R0174 Q728.1Y POA
* 1997 or later.
Spares161
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSOR SPARES - FRASCOLD MK II
FRASCOLD MK II - SEMI-HERMETICRealcoldStock No.
To Suit System Price$ Excl. GST
Bearing SetR0271 A075, A16, A157, B159, B210 POAR0281 D213, D313, D318 POAR0291 F416, F424, F519, F524, POAR0302 S Series MK3 POAR0312 V1559, V2059, V1571, V2071, V2084,
V2584, Z25106, Z35106, Z30126, Z40126, Z40154, Z50154
POA
R0314 W50187, W60187, W60206, W70206 POA
Valve Plate AssemblyR0421 A075, A157 POAR0442 B210 POAR0443 D213 POAR0444* D213 POAR0448* D313, D318, Q728 POAR0469* F519, S733, S1039 POAR0479* F424 POAR0481* F524 POAR0484* F728 POAR0499* S739 POAR0505 S1051 POAR0507* S1551 POAR0509 S1551 POAR0514 V1559 POAR0515 V2059 POAR0538 V1571, Z25106 POAR0535 Z35106, V2571 POAR0539 V2084, Z30126 POAR0536 V2584, Z40126 POAR0540 Z40154 POAR0541 Z50154, W70206 POAR0542 W60206 POAR0543 W50187 POAR0544 W60187 POAR0422 A16 POAR0423 B159 POAR0468 F416 POAR0511 S1551 POA
Discharge Valve C/W GasketR0561 1/2 MF A075, A16, A157, B159 POAR0571 5/8 MF B210 POAR0572 5/8 OD D213, D313, D318 POAR0601 3/4 OD F416, F424, F519, F524 POAR0603 3/4 OD F524, F528, Q528 POAR0610 1.1/8 OD (Flange Type)
V1559,V1571, V2059, V2071, V2084
POA
R0653 1.3/8 OD (Flange Type) Z25106, Z30126, Z35106
POA
R0670 1.5/8 OD (Flange Type) Z40126, Z40154, Z50154
POA
R0672 2.1/8 OD (Flange Type) W60206, W70206
POA
Suction Valve C/W Gasket
R0563 5/8 MF A075, A16, A157, B159 POAR0602 3/4 OD B210 POAR0603 3/4 OD D213 POAR0581 7/8 OD D213 POAR0592 1.1/8 OD D313, D318 POAR0593 1.1/8 OD F416, F424, F519, F524 POAR0670 1.5/8 OD (Flange Type)
V1559, V1571, V2059, V2071, V2084
POA
R0675 2.1/8 OD (Flange Type) V2584, Z25106, Z30126, Z35106
POA
R0676 2.5/8 OD W50168, W50187, W60187, W60206, W70206
POA
R0677 2.5/8 OD (Flange Type) Z40126, Z40154, Z50154, W5018, W60187, W60206, W70206
POA
Thrust Bearing Assembly
R0309 Thrust Washer Assy. W Series POA
Semi-Hermetic Frascold MKII - MiscellaneousR0727 Oil Pump Assembly to suit V & Z series POA
R0726 Oil Pump Assembly to suit W series POA
R0850 Kriwan 69P Module Solid State Oil Protection Control (V, Z, W Modules)
POA
R0730 Compressor Sight Glass c/w 'O' Ring POA
R0731 Oil Balance Valve (to suit any compressor with sight glass)
POA
R0735 Oil Filter Screen Assy V, Z, W Series POA
R0720 Suction Screen V Series POA
R0737 Oil Balance Line Attachments POA
R0965 Sensor Electronic Injection POA
R0966 Unloader Solenoid Valve W/ Coil POA
R0967 Coil 230V 50/60HZ 10W POA
R0968 Plug IP67 POA
R0969 Gasket Sol. Valve POA
Semi-Hermetic Screw Compressor - Miscellaneous
R1002 Oil Flow Switch POA
R1003 Oil Filter Cartridge POA
R1005 Kriwan INT 69V Lubrication POA
R1006 Oil Level Control POA
R1007 Oil Heater 300W POA
R1008 Thermostat / Sensor POA
R1009 Thermostat / Pocket POA
R1010 Bearing Set C-TSH8 120 360Y POA
R1011 Gasket Set C-TSH8 120 360Y POA
R1012 Module INT 69 FRY POA
R1013 Frascold Oil Heater - Screw POA
R1014 Oil Lever Control CTSH 100-300 POA
R1015 Suction Filter POA
R1016 Oil Flow Switch Kit POA
R1017 Oil Strainer - Screw POA
R1018 Suction Valve Kit POA
* 1997 or later.
Spares162
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSOR SPARES - FRASCOLD MK II
Electrics To Suit Three Phase ModelsRealcoldStock No.
To Suit System Price$ Excl. GST
R0820 Thermistor Module All Models, 3 phaseI NT69
POA
R0822 Thermistor Module with delay INT 69TM-V, Z, W
POA
Part Winding Start 380/415Volt 50HzRealcoldStock No.
To Suit System Price$ Excl. GST
R0879 15HP Assembly
Suits S1551
POA
R0880 Stator/Rotor Assembly 20 HP
Suits V2059, V2071, V2084
POA
R0882 Stator/Rotor Assembly 25 HP
Suits V2584, Z25106
POA
R0884 Stator/Rotor Assembly 30 HP
Suits Z30126
POA
R0886 Stator/Rotor Assembly 35 HP
Suits Z35106
POA
R0888 Stator/Rotor Assembly 40 HP
Suits Z40126, Z40154
POA
R0890 Stator/Rotor Assembly 50 HP
Suits Z50154
POA
R0892 Stator/Rotor Assembly 50 HP
Suits W50187
POA
R0894 Stator/Rotor Assembly 60 HP
Suits W60187, W60206
POA
R0896 Stator/Rotor Assembly 70 HP
Suits W70206
POA
Electrics To Suit Single Phase ModelsRealcoldStock No.
To Suit System Price$ Excl. GST
A075, KEY 007
R0800 Relay RVA4M3C POA
R0830 Overload EL1 POA
R0790 Capacitor Start 160-200uf 380V POA
R0780 Capacitor Run 16uf/450V POA
A16, NEO 010
R0800 Relay RVA4M3C POA
R0830 Overload EL1 POA
R0790 Capacitor Start 160-200uf 380V POA
R0810 Capacitor Run 20uf/450V POA
A157, FRU 15
R0750 Relay RVA4N3C POA
R0842 Overload EL3 (A157) POA
R0760 Capacitor Start 200-250uf 380V POA
R0770 Capacitor Run 25uf/450V POA
B159, TER 15
R0750 Relay RVA4N3C POA
R0842 Overload EL3 (B159) POA
R0760 Capacitor Start 200-250uf 380V POA
R0770 Capacitor Run 25uf/450V POA
Spares163
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
RITCHIE - YELLOW JACKET VACUUM PUMP SPARES
Ritchie - Yellow Jacket Vacuum Pump SparesRealcoldStock No.
Model Description System Price$ Excl. GST
T2451 93441 Replacement cartridge for 95 L pump POA
T2452 93461 Replacement cartridge for 142 L pump POA
T2453 93012 Crystal for Vacuum Gauge Suits Vacuum Pumps POA
T2454 93011 Vacuum Gauge POA
T2456 93098 Oil Drain Valve 70-120-18 L POA
T2457 93403 Oil Sight Glass (fits pumps manufactured up until 1997) POA
T2467 93365 Oil Sight Glass (fits 95 and 142 l/m pumps (manufactured from 1998 on) POA
T2458 93404 Oil Case Gasket (fits 95 and 142 l/m pumps (manufactured from 1998 on) POA
T2459 93386 Exhaust Filter POA
T2460 93387 Filter Element POA
T2461 93114 Motor Switch POA
T2462 93047 Drive Coupling POA
T2463 93344 Gasket - Oil Cover Case 35L POA
T2464 93031 Shaft Seal POA
T2465 93045 Motor Capacitor POA
T2466 93078 Oil Case Screw POA
T2468 93048 Oil Cover Gasket 85-96 Suits Vacuum Pumps POA
T2469 93369 Oil Cover Gasket 98-05 Suits Vacuum Pumps POA
T2470 93146 Electric Motor 115/230V 50/60 Hz POA
T2471 93507 Oil Cover Gasket 05 Suits Vacuum Pumps POA
T2472 93368 Gas Ballast 93368 Suits Vacuum Pumps POA
T2473 93509 Gas Ballast 93509 Suits Vacuum Pumps POA
T2474 93032 O-Ring Gas Ballast 93032 Suits Vacuum Pumps POA
T2475 93398 O-Ring Gas Ballast 93398 Suits Vacuum Pumps POA
T2476 93117 Rocker Switch 93117 POA
Note: Except for the cartridges, all other spares are inter-changeable.
Spares164
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
RITCHIE - YELLOW JACKET SPARES
Ritchie - Yellow Jacket SparesRealcoldStock No.
Model Description To Suit System Price$ Excl. GST
Manifold PartsT2609 19015 Gasket T2206 CH-80 3.83T2610 41103 3/8" Piston 48584 18.55T2611 41043 Titan Piston Assembly 49833, 49869 16.50T2612 41133 1/4" Piston 41382, 42010 13.40T2614 41134 Feed Screw 41382, 48584 17.55T2615 41056 Titan/Bantam Feed Screw 49833, 49869, 45936 13.40T2616 41107 Retaining Nut 48584 20.60T2617 41094 Brute II Red Handle 46140, 46160 13.40T2618 41104 Red Handle 48584 13.40T2619 41044 Titan Red Handle 49833, 49869 13.40T2620 41102 Blue Handle 48584 13.40T2621 41092 Brute II Blue Handle 46140, 46160 13.40T2622 41101 Yellow Handle 48584 13.40T2623 41042 Titan Blue Handle 49833, 49869 13.40T2624 41142 Handle Screws (Set of two) 41382, 48584 7.20T2625 41091 Brute II Yellow Handle 46140, 46160 13.40T2626 41041 Titan Yellow Handle 49833, 49869 13.40T2627 41090 Handle Screws Brute II 46140, 46160 7.20T2628 40279 Hanging Hook 41382, 48584 11.85T2629 41048 Titan Handle Screw 49833, 49869 7.20T2630 41108 Sight Glass 48584 48.95T2631 41096 Retaining Nut Brute II 46140, 46160 20.60T2633 41049 Retaining Nut Titan 49833, 49869 11.35T2632 41109 Sight Glass "O"-Ring 48584 8.75T2634 41135 Retaining Nut 41382 11.35T2636 41141 Handle Screw & Washer 41382 10.25T2641 41051 Yellow Handle 45836, 45936 13.40T2642 41052 Blue Handle 45836, 45936 13.40T2643 41053 Piston / "O"-Ring 45836, 45936 16.50T2644 41054 Red Handle 45836, 45936 13.40T2645 41055 O-Rings 45836, 45936 1.85T2646 41056 Feed Screw 45836, 45936 13.95T2647 41057 Retaining Nut 45836, 45936 11.35T2648 41058 Handle Screw/Washer 45836, 45936 7.20T2650 41061 Sight Glass Assembly 45836, 45936 48.95T2651 41131 Manifold O-Rings Series 41 42010 1.85T2653 41134 Series 41 Valve Feed Screw 42010 13.95T2657 41143 Series 41 Valve Assembly 42010 33.00T2658 41047 O-Ring Sight Glass Brute II and Titan 9.80
Flaring & Swaging Tool SparesT2558 60443 Yoke for 60440 154.00T2560 60213 Yoke for 60210 61.30T2562 60271 Yoke for 60270 143.00T2564 60212 Flaring Bar 3/16” - 5/8” for 60210, 60440 79.35T2566 60232 Flaring Bar 1/2” - 3/4” for 60210, 60440 140.00T2568 60449 Flaring Cone only 42.75
Swage AdaptorsT2580 60444 Swage Adapter 3/16” - 3/8” 51.00T2581 60439 Swage Adapter 1/4” 50.00T2582 60445 Swage Adapter 5/16” 50.00T2583 60446 Swage Adapter 1/2” 50.00T2584 60447 Swage Adapter 5/8” 50.00T2585 60448 Swage Adapter 3/4” 51.00
Spares165
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
REALCOLD EVAPORATOR SPARES
Realcold Evaporator SparesRealcoldStock No.
Description To Suit System Price$ Excl. GST
W7500 Fan Motor Rondo 140-700, RDD 300-900, RCT 240-540 POA
W7501 Fan Blade Rondo 140-700, RDD 300-900, RCT 240-540 POA
W7502 Fan Guard Rondo 140-700, RDD 300-900, RCT 240-540 POA
W7503 Bracket Rondo 140-700, RDD 300-900, RCT 240-540 POA
W7504 Fan Motor Rondo 900-1300 and RCM 1300-2500 and NST range POA
W7505 Fan Blade Rondo 900-1300 and RCM 1300-2500 POA
W7506 Fan Guard Rondo 900-1300 and RCM 1300-2500 POA
W7507 Bracket Rondo 900-1300 and RCM 1300-2500 POA
W7511 Fan Blade NST range POA
W7512 Fan Guard NST range POA
W7513 Fan Motor RDD 100-200 and RCT 160 POA
W7514 Fan Blade RDD 100-200 and RCT 160 POA
W7515 Fan Guard RDD 100-200 and RCT 160 POA
W7516 Bracket Ring Mount RDD 100-200 and RCT 160 POA
W7517 Electric Lead w/plug 1500 mm POA
W7518 Electric Lead w/plug 3000 mm POA
W7521 Terminal Box POA
W7535 Fan Assy - RST POA
Fan Guards
D0182 Fan Guard 200 mm Fan POA
D0183 L’Unite 200 mm AEZ / AE cond units (large - 2 piece) POA
D0184 Fan Guard 200 mm Fan POA
D0185 L’Unite 250 mm CAE / CAJ cond units (small - 1 piece) POA
D0186 L'Unite 300 mm CAJ cond units (large - 1 piece) POA
D0187 L'Unite 356 mm FH / TFH cond units (1 piece) POA
M0160 To suit 879-300 (M0159) Fan Motor POA
Spares166
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
REALCOLD EVAPORATOR DEFROST ELEMENT
Realcold Evaporator Defrost ElementRealcoldStock No.
Description Length Quantity Per Unit Watts (230V) System Price$ Excl. GST
Tray - U Core Tray - U Core Tray - U Core
W7200 F04806 U-Shaped Element
to suit NL112, NL115, NL118
560 1 1400 POA
W7202 F04807 U-Shaped Element
to suit NL120, NL123
765 1 1800 POA
W7204 F04808 U-Shaped Element
to suit NL228, NL234, NL239
1065 1 2400 POA
W7206 F04973 U-Shaped Element
to suit SL261
1320 1 2000 POA
W7208 F04809 U-Shaped Element
to suit NL347, NL364
1565 1 3600 POA
W7210 F04810 U-Shaped Element
to suit NL455, NL468, SL374, SL392, SL3110
2065 1 4800 POA
W7212 F04974 U-Shaped Element
to suit SL4120, SL4145
2560 1 3200 POA
W7220 F03170 Tray Element
to suit VL2280
2170 2 1800 POA
W7222 F03205 Tray Element
to suit RL3160, RL3185, RL3200, VL2300
2560 (RL3160, RL3200),
3170 (RL3185),
2670 (VL2300)
2 3200, 1800 (RL3200)
POA
W7224 F03240 Tray Element
to suit SL5180, RL4220, RL4250, VL3350, VL3400
3170 1 (SL5180),
2
1800 (SL5180, VL3400),
3200
POA
W7226 F04178 Tray Element
to suit VL4450
3475 2 3200 POA
W7228 F02925 Tray Element
to suit VL4500
3820 2 3600 POA
W7240 F03617 Core Element
to suit SL261, SM271P
1260 3
2 (SM271P)
750 POA
W7242 F02785 Core Element
to suit SL374, SL392, SL3110, VL2280, SM386P, SM3105P, SM3125P
2000 3 (SL374, SL392),
4 (SL3110),
6 (VL2280)
2 (SM386P, SM3105P, SM3125P)
1200 POA
W7244 F02820 Core Element
to suit SL4120, SL4145, RL3160, RL3200, VL2300, SM4140P, SM4165P
2500 3 (SL4120, SL4145),
4 (RL3160),
6 (RL3200, VL2300)
2 (SM4140P, SM4165P)
1500 POA
W7246 F02855 Core Element
to suit SL5180, RL4220, RL4250, VL3350, VL3400, SM5210P
3000 4 (SL5180),
6 2 (SM5210P)
1800 POA
W7248 F03668 Core Element
to suit VL4450
3350 6 2000 POA
W7250 F02890 Core Element
to suit VL4500
3650 6 2200 POA
CX167
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Com
pone
nts
COMPRESSOR AND CONDENSING UNIT WARRANTY
CompressorsRealcold Ltd standard warranty covers the start up of all com-pressors. For extended warranty the following charges apply:
Extended Warranty Charges
Sealed Compressors - All brands - 4% on sale price
Semi-Sealed Compressors - All brands - 4% on sale price
Compressors will be repaired or replaced under warranty if returned within 12 months of purchase date, provided that com-pressor, complete with original electrics, is returned to point of purchase, freight paid, accompanied by a compressor failure report.
Realcold Ltd shall not be held responsible for failure or damage resulting from misuse or incorrect installation.
Condensing UnitsSealed & Semi-Sealed
Warranty is included in the price listed for condensing units and includes replacement of all components for a 12 month period from date of purchase, provided component is returned along with Goods Returned Form to point of purchase, freight paid.
Note:
Replacement components will be debited against the account of the purchaser, with credit to follow upon receipt and inspection of faulty component.
Realcold Ltd shall in no event be liable for any indirect or conse-quential loss or damage whatsoever.
Refer to the back of this catalogue for our General Terms of Trade. Goods Returned Forms are available from your representative, or any of our branches.
COMPRESSOR AND CONDENSING UNIT WARRANTY
Indu
stria
l
IndustrialHansen Introduction IN170
Stop And Regulating Valves IN171
Pressure Regulators IN172
Control Valve Pilots IN173
Strainers IN175
Flanges And Adaptor Rings IN176
Complete Valve Combination IN177
Solenoid Valves IN178
Pressure Relief, Gauge & Transducer Valves IN179
Float Controls, Level Probes & Switches, Sight Glasses IN180
Auto Purgers IN181
Check Valves IN183
Multi Port Valves IN184
Motorised Valves IN185
2-Step Solenoid, Suction Stop & Oil Change Valves IN186
Ammonia & Other Gas Sensors IN187
Refrigerant Pumps IN188
Valves - Solenoid Coils IN191
Valves - Spares IN192
IN170
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
HANSEN INTRODUCTION
Hansen is one of the largest manufacturers of Industrial Refrigeration Products in the world.
Manufactured in the USA and exported world wide, the Hansen brand is synonymous with quality, performance and reliability.
As well as producing the normal range of valves, controls and float switches, Hansen also market a range of Auto-Purgers, Motorized Valves, Ammonia Detectors, Refrigerant Pumps (for Ammonia Carbon Dioxide and other industrial gases) and specialist controllers designed specifically for the Industrial Refrigeration Market.
Bespoke Control Valves: We can assemble almost any combination of valve from stocked, modular valve bodies and pilots to satisfy the majority of applications that you might require.
Additionally, we are able to fit the full range of Danfoss Pilots and controllers onto the Hansen modular bodies, to meet your requirements. Most of these items are available ex-stock from our Auckland Central Warehouse and can be made up to order.
Refrigerant Float Switch: The HLLE refrigerant liquid level float switches are used to electrically indicate or control a liquid level, by opening or closing a SPDT switch. Their simple, reliable design provides a life time of per-formance for almost any application
Applications: These refrigerant level float switches are typically installed on a vessel’s liquid level column. They can control liquid level by activating a liquid fill solenoid valve. Often, they are used to provide high level cut-out or alarm. They are often used to turn off a recirculating liquid pump if a low level occurs. Other applications include control of liquid level via a liquid exit solenoid valve, level indication via a pilot light, and transfer drum operation.
Techni-Level Transducer Probes: The Hansen Techni-Level has fast become the industry standard for liquid refrigerant level control and monitoring. These reliable, well engineered electronic level transducer probes, when properly used, operate trouble free and are not affected by reasonable changes in refrigerant temperature or pressure. They provide a computer compatible 4-20 mA (milliamp) output signal proportional to liquid level.
Probes consist of a compact, electronic transmitter in a watertight housing assembled on top of a rugged, capacitance type level sensor. Normally, the probe must be inside a level column.
Typical applications include: vertical and horizontal vessels, pump accumulators, pilot receivers, and refrigerant loss monitoring. These probes are operating control devices and should never be used as safety devices.
Hansen Auto Purgers: A variety of Auto Purgers are available from the mini Non-Electric Auto Purger (NEAP) to the Auto Purger Plus. These units reduce condensing pressure and lower power costs by removing non-condensable gas and water from Ammonia and Halocarbon refrigeration systems.
For more information on industrial products please call +64 (0)9 526 5955.
IN171
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
STOP AND REGULATING VALVES
Hansen Stop Valves - AmmoniaRealcoldStock No.
Description System Price$ Excl. GST
Straight Through (Globe) Stop Valves - Socket Weld
12993 Hansen GSB051H Shut Off 15SW 166.00
12997 Hansen GSB076H Shut Off 20SW 200.00
13001 Hansen GSB100H Shut Off 25SW 222.00
13005 Hansen GSB125H Shut Off 32SW 287.00
13009 Hansen GS150H Shut Off 40SW 434.00
Right Angle Stop Valves - Socket Weld (SW) Or Butt Weld (BW)
12994 Hansen ASB051H Shut Off 15SW 169.00
12998 Hansen ASB076H Shut Off 20SW 202.00
13002 Hansen ASB100H Shut Off 25SW 225.00
13006 Hansen ASB125H Shut Off 32SW 309.00
13010 Hansen AS150H Shut Off 40SW 434.00
13014 Hansen AS200H Shut Off 50SW 501.00
13018 Hansen AS251H Shut Off 65SW 672.00
12960 Hansen AW301H Shut Off 80BW 1,000.00
12964 Hansen AW402H Shut Off 100BW 1,296.00
12968 Hansen AW500H Shut Off 125BW 2,191.00
12972 Hansen AW600H Shut Off 150BW 2,533.00
12976 Hansen AW800H Shut Off 200BW 5,379.00
Note: NB for straight through, use with a 45° elbow welded to each branch. The above stop valves are also suitable for HCFCs, HFCs, and other approved refrigerants. Valves larger than 65 mm are Butt Weld. Smaller valves may be of either type.
Hansen Hand Regulating Valves - AmmoniaRealcoldStock No.
Description System Price$ Excl. GST
Angle Or Globe Regulating Valve - Socket Weld, With Cap
13137 Hansen VSB050C Hand Exp 15SW 186.00
13141 Hansen VSB076C Hand Exp 20SW 210.00
13145 Hansen VSB100C Hand Exp 25SW 258.00
13149 Hansen VSB125C Hand Exp 32SW 325.00
13069 Hansen VS150C Hand Exp 40SW 499.00
Hansen Stop Check Valves - AmmoniaRealcoldStock No.
Description System Price$ Excl. GST
Angle Stop/ Check Valve - Socket Weld Or Butt Weld With Cap
12039 Hansen HSCK125C Stop/Check 32SW 768.00
12040 Hansen HSCK150C Stop/Check 40SW 833.00
12041 Hansen HSCK200C Stop/Check 50SW 1,150.00
12042 Hansen HSCK250C Stop/Check 65BW 1,585.00
12043 Hansen HSCK300C Stop/Check 80BW 2,046.00
12044 Hansen HSCK400C Stop/Check 100BW 2,638.00
12045 Hansen HSCK500C Stop/Check 125BW 4,198.00
12046 Hansen HSCK600C Stop/Check 150BW 5,309.00
IN172
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
PRESSURE REGULATORS
Hansen Pressure Regulators RealcoldStock No.
Model Description System Price$ Excl. GST
17382 AR1-20 Main Valve Single Port 20mm (3/4”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
439.00
17383 AR1-25 Main Valve Single Port 25mm (1”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
645.00
17384 AR1-32 Main Valve Single Port 32mm (1 1/4”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
887.00
17385 AR1-40 Main Valve Single Port 40mm (1 1/2”) Regulating Valve Body.
Flange options 11944, 11948, 11947, 11951
1,330.00
17386 AR1-50 Main Valve Single Port 50mm (2”) Regulating Valve Body.
Flange options 11944, 11948, 11947, 11951
1,573.00
17387 AR1-65 Main Valve Single Port 65mm (2 1/2”) Regulating Valve Body.
Flange options 11952, 11962
2,049.00
19763 AR1-80 Main Valve Single Port 80mm (3”) Regulating Valve Body.
Flange options 11956, 11958
2,968.00
17388 AR3-20 Main Valve Three Port 20mm (3/4”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
598.00
17389 AR3-25 Main Valve Three Port 25mm (1”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
792.00
17390 AR3-32 Main Valve Three Port 32mm (1 1/4”) Regulating Valve Body.
Flange options 11929, 11933, 11936, 11932, 11942, 11943
1,046.00
17391 AR3-40 Main Valve Three Port 40mm (1 1/2”) Regulating Valve Body.
Flange options 11944, 11948, 11947, 11951
1,467.00
17392 AR3-50 Main Valve Three Port 50mm (2”) Regulating Valve Body.
Flange options 11944, 11948, 11947, 11951
1,731.00
17393 AR3-65 Main Valve Three Port 65mm (2 1/2”) Regulating Valve Body.
Flange options 11952, 11962
2,209.00
17394 AR3-80 Main Valve Three Port 80mm (3”) Regulating Valve Body.
Flange options 11958, 11956
3,128.00
Note: See page IN176 for flange descriptions.
AR1 Body
AR3 Body
Features
• AR Series are base valve bodies which can be made into a variety of Pilot and Solenoid valve combinations. The head will accept either Hansen or Danfoss Pilots as required, and will also operate with a variety of proprietary controllers.
• All valves are spring closing, and have Teflon seats, with V-port modulation.
• Safe Working Pressure 2758 kPa G (400 psig).
• Operating Temperature -40°C to 115°C (-60°F to 240°F).
• Suitable for Ammonia, Carbon Dioxide, HCFCs, HFAs, and other approved refrigerants.
• Suitable for use with suction gas, liquid, defrost relief, discharge gas, and other applications.
• Additionally, Realcold offers complete Solenoid and Control Valves according to your application.
• Contact Realcold to advise on suitable control combinations.
IN173
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
CONTROL VALVE PILOTS
Hansen Individual Pilot ApplicationsOption Description Range
0 -
150
psig
(0
to 1
0 ba
r)
30 -
300
psig
(+
2 to
+21
bar
)
100
to 5
50 p
sig
(6 -
38
bar)
30 to
450
psi
g (0
to 3
1 ba
r)
20”
to 1
30 p
sig
(-0.
67 to
+9
bar)
S Electric Shut-Off
Controls Pressure when electronically energised; closed when not energised. For temperature control and defrost, or similar uses. Specify Voltage, Range and Special Variation if required.
ü ü ü ü ü
B Electric Wide Opening
Controls pressure when not electrically energized; open when energized. For defrost regulation or heat recovery and wide opening for maximum cooling or similar. Specify Voltage, Range and Special Variation if required.
ü ü ü ü ü
D Dual Pressure Regulator
Controls at lower pressure when electrically energised, at higher pressure when not energized. Used for two pressure (temperature) control or defrost pressure relief and pressure (temperature control. Specify Voltage, Range and Special Variation if required.
ü ü ü ü ü
L Differential Pressure
For pump relief, oil control or any differential controlü
O Outlet Pressure
Opens as outlet pressure drops. For hot gas bypass to suction, crankcase pressure control or for other receiver pressure control.
ü ü
K Reseating Relief
Defrost relief or high to low system relief. Set and tagged. Specify setting or otherwise setting will be at 70 psig (4.8 bar)
ü ü ü ü
R Regulator Only with External Connection for Remote Pilot
Enables a remote pressure source to be introduced to the regulator via a pilot line (replaces a pilot).
P Pneumatically Controlled
Air pressure or other pressure in bonnet raises inlet pressure at 1:1 ratioü
Q Electronic Control Module
Precise temperature control or liquid chiller control. For indoor or outdoor use. Simple design; 4-20 mA control. Transformer included. Control range 0 - 87 psig.
ü
M Electric Motor Compensated
Commonly used for precise room temperature control or liquid chiller control. A motor changes regulator pressure setting in accordance with temperature controller. Includes control module, Cam, motor bracket and Penn motor 4020 mA standard. (Honeywell motor available)
ü ü
M3B Stopping Plug (Straight Through)
To be used in a Control Port when the port is not utilised.ü ü ü ü ü
M3S Stopping Plug (Stopping)
To be used in a Control Port when the port is not utilised.ü ü ü ü ü
M3O
MS
M3S
M3B
M3L
M3K
IN174
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
CONTROL VALVE PILOTS
Hansen Pressure PilotsRealcoldStock No.
Model Description System Price$ Excl. GST
11794 75-1097 Hansen M3 Pilot Range A (0 To 10 Bar); Inlet Pressure Control Module For All Pressure Regulators
416.00
11795 75-1098 Hansen M3 Pilot Range B (2 To 21 Bar); Inlet Pressure Control Module For All Pressure Regulators
416.00
17401 75-1099 Hansen M3 Pilot Range V (-0.67 To 9 Bar); Inlet Pressure Control Module For All Pressure Regulators
650.00
18932 75-1126 Hansen M3W Pilot Range A (0 To 10 Bar); Compact Inlet Control Module For All Pressure Regulators Up To And Including 32 mm
416.00
11796 75-1100 Hansen M3O Pilot Range V (-0.67 To 9 Bar); Outlet Pressure Control Module 804.00
11797 75-1101 Hansen M3O Pilot Range B (2 To 21 Bar); Outlet Pressure Control Module 804.00
11798 75-1103 Hansen M3K Pilot Range A (0 To 10 Bar); Reseating Relief Control Module For 40 mm Press Regulator And Above
500.00
11799 75-1104 Hansen M3K Pilot Range B (2 To 21 Bar); Reseating Relief Control Module For All Press Regulators
500.00
13961 75-1081 Hansen M3P Pilot Range A (0 To 10 Bar G); M3P/L Pneumatically Compensated Or Differential Pressure; Control Module For All Press Regulators
553.00
17402 75-1064 Hansen M3B Through Blanking Plug 27.85
17403 75-1063 Hansen M3S Stopping Blanking Plug 27.85
Danfoss Pressure PilotsRealcoldStock No.
Model Description System Price$ Excl. GST
16736 027B110000 Danfoss (LP) Pilot Valve 0 To 7 Bar Range; Constant Press For PM Main Valves; 17 Bar MWP; 0.4m^3/H KV
POA
16735 027B107000 Danfoss CVC (LP) Pilot Valve 0 To 7 Bar Range; Outlet Pressue Pilot; 17 Bar MWP; 0.4m^3/H KV
POA
16739 027B111000 Danfoss CVT Pilot Valve -40 To 0 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV
POA
16740 027B111100 Danfoss CVT Pilot Valve -10 To 25 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV
POA
16741 027B111200 Danfoss CVT Pilot Valve 20 To 60 deg C Range; Temp Operated For Pm Main Valves; Opens On Rising Temp; 22 Bar MWP; 0.2m^3/H KV
POA
16743 027B114000 Danfoss CVQ Pilot Valve 0 To 6 Bar Range; Electronically Operated Constant Press For PM Main Valves; 17 Bar MWP; 0.45m^3/H KV
POA
16744 027B114100 Danfoss CVQ Pilot Valve 1.7 To 8 Bar Range; Electronically Operated Constant Press For PM Main Valves; 17 Bar MWP; 0.45m^3/H KV
POA
16745 027B116000 Danfoss CVP (HP) Pilot Valve 4 To 22 Bar Range; Constant Press For Pm Main Valves + CVH Housing; 28 Bar Mwp; 0.4m^3/H KV
POA
16746 027B116200 Danfoss CVPP (HP) Pilot Valve 4 To 22 Bar Range; Differential Press For PM Main Valves; 28 Bar MWP; 0.4m^3/H KV
POA
Range A 0 - 150 psig (0 to 10 Bar)
Range B 30 - 300 psig (+2 to +21 Bar)
Range C 100 to 550 psig (6 - 38 Bar)
Range D 30 to 450 psig (0 to 31 Bar)
Range V 20” to 130 psig (-0.67 to +9 Bar)
IN175
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
STRAINERS
Hansen Strainers/Filters - SteelHansen Strainers have a stainless steel screen, 60 mesh (233 micron rating). Groove inlet, tongue outlet. Safe Working Pressure: 2758 kPa (400 psig). Applications include liquid lines, hot gas lines, suction lines, and oil lines. Strainers are supplied ready to be close-coupled to solenoid valves, pressure regulators, etc. For installation as a separate unit, a flange installation kit is required (see below).
RealcoldStock No.
Model Description System Price$ Excl. GST
12051 ST050 To fit 13 mm Port (less flanges) 118.00
12056 ST100 To fit 20 mm, 25 mm, 32 mm Port (less flanges) 306.00
12069 ST200 To fit 40 mm, 50 mm Port (less flanges) 675.00
12078 ST250 To fit 65 mm Port (less flanges) 940.00
12079 ST300 To fit 80 mm Port (less flanges) 1,585.00
12080 ST400 To fit 100 mm Port (less flanges) 1,585.00
Hansen Flange Conversion KitHansen Flange Conversion Kits include bolts, gaskets, and female adaptor ring, to allow a strainer to be installed as a separate item.
RealcoldStock No.
Description System Price$ Excl. GST
17405 To suit ST050 Strainer 59.75
17406 To suit ST100 Strainer 77.25
17407 To suit ST200 Strainer 183.00
17408 To suit ST250 Strainer 211.00
Herl Angle Strainers/Filters - SteelRealcoldStock No.
Description System Price$ Excl. GST
17323 32 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16912 40 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16913 50 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16914 65 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16915 80 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16916 100 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
17317 125 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16917 150 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
16918 200 mm Butt Weld; Angle Strainer; 0.5 mm Mesh POA
IN176
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
FLANGES AND ADAPTOR RINGS
Hansen Flanges & Flange KitsThe Hansen flange system is generally interchangeable for Parker Refspec, Henry, and York/Frick flanges. A flange kit is two male (tongued) flanges (of the same size and style) to suit a Hansen flanged valve. Gaskets, bolts, and nuts are provided with the valve, or can be purchased separately.
RealcoldStock No.
Description System Price$ Excl. GST
Item Connection Vendor Model No. Bolts Per Flange
11925 Flange Kit 1/2" FPT # 050 (2-Bolt) 69.05
11923 Flange Kit 1/2" SW # 050 (2-Bolt) 69.05
11926 Flange Kit 3/4" SW # 050 (2-Bolt) 69.05
11929 Flange Kit 3/4" SW # 100 (2-Bolt) 89.65
11933 Flange Kit 1" SW # 100 (2-Bolt) 89.65
11936 Flange Kit 1.1/4" SW # 100 (2-Bolt) 89.65
11939 Flange Kit 1.1/2" SW # 100 (2-Bolt) 79.35
11944 Flange Kit 1.1/2" SW # 200 (4-Bolt) 143.00
11948 Flange Kit 2" SW # 200 (4-Bolt) 143.00
11952 Flange Kit 2.1/2" SW # 250 (4-Bolt) 252.00
11919 Flange Kit 5/8" OD # 050 (2-Bolt) 88.60
11932 Flange Kit 7/8" OD # 100 (2-Bolt) 128.00
11942 Flange Kit 1.1/8" OD # 100 (2-Bolt) 128.00
11943 Flange Kit 1.3/8" OD # 100 (2-Bolt) 128.00
11947 Flange Kit 1.5/8" OD # 200 (4-Bolt) 184.00
11951 Flange Kit 2.1/8" OD # 200 (4-Bolt) 184.00
11955 Flange Kit 2.5/8" OD # 250 (4-Bolt) 306.00
Hansen Adaptor RingsRealcoldStock No.
Description System Price$ Excl. GST
Female Adaptor Rings. Female adaptor rings are used at the outlet of strainers installed as separate flange units.
17374 FAR 050 Female Adaptor Ring 27.85
17375 FAR 100 Female Adaptor Ring 27.85
17376 FAR 200 Female Adaptor Ring 112.00
17377 FAR 250 Female Adaptor Ring 143.00
Male Adaptor Rings. Male adaptor rings are used to close-couple HCK4 or HCK1 check valves to the outlet of valves and regulators.
17378 MAR 050 Male Adaptor Ring 35.05
17379 MAR 100 Male Adaptor Ring 35.05
17380 MAR 200 Male Adaptor Ring 59.75
17381 MAR 250 Male Adaptor Ring 71.10
Henry Flange Union KitsRealcoldStock No.
Description System Price$ Excl. GST
Item Connection Vendor Model No. Bolts Per Flange
17685 Flange Kit 1/2" SW 02SW-1x1/2 (2-Bolt) 206.00
17686 Flange Kit 3/4" SW 02SW-1x3/4 (2-Bolt) 217.00
17687 Flange Kit 1" SW 02SW-1 (2-Bolt) 206.00
17688 Flange Kit 1.1/4" SW S2SW-1-1/4 (4-Bolt) 296.00
17689 Flange Kit 1.1/2" SW S2SW-2x1-1/2 (4-Bolt) 352.00
17690 Flange Kit 2" SW S2SW-2 (4-Bolt) 335.00
17691 Flange Kit 2.1/2" SW S2SW-2-1/2 (4-Bolt) 391.00
17692 Flange Kit 3" SW S2SW-3 (4-Bolt) 446.00
17693 Flange Kit 4" SW S2SW-4 (4-Bolt) 525.00
Note: The HENRY flange system consists of 1 Female and 1 Male Flange, complete with bolts and nuts.
IN177
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
COMPLETE VALVE COMBINATION
Hansen Control Valves - SteelCosts for larger valves are available on request. We are able to make up most valves up to 80 mm from our stock of Control Valve bodies and pilots. Non-stock pilots can be supplied within 5-7 working days from placement of order however there may be additional courier costs.
Many Danfoss pilots and electronic controllers are also available for substitution if required. The Hansen modular control head is designed to fit both ranges of control pilots.
RealcoldStock No.Without Strainer
RealcoldStock No .With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
11817 - HA2B Small Pressure Regulator 1/2" SW 462.00 -
11411 11415 HA4A-20 Modular Pressure Regulator 3/8” SW 665.00 972.00
11431 11435 HA4A-25 Modular Pressure Regulator 1” SW 857.00 1,163.00
11444 11448 HA4A-32 Modular Pressure Regulator 1 1/4” SW 1,110.00 1,416.00
11458 11462 HA4A-40 Modular Pressure Regulator 1 1/2” SW 1,608.00 2,283.00
11472 11476 HA4A-50 Modular Pressure Regulator 2” SW 1,849.00 2,524.00
11480 11483 HA4A-65 Modular Pressure Regulator 3” SW 2,436.00 3,376.00
11486 11490 HA4A-80 Modular Pressure Regulator 3” SW 3,384.00 4,519.00
11506 11510 HA4AS-20 Electric Shut Off Regulator 3/8” SW 1,226.00 1,532.00
11526 11530 HA4AS-25 Electric Shut Off Regulator 1” SW 1,519.00 1,825.00
11539 11543 HA4AS-32 Electric Shut Off Regulator 1 1/4” SW 1,676.00 1,982.00
11553 11557 HA4AS-40 Electric Shut Off Regulator 1 1/2” SW 2,171.00 2,845.00
11567 11571 HA4AS-50 Electric Shut Off Regulator 2” SW 2,412.00 3,086.00
11575 11578 HA4AS-65 Electric Shut Off Regulator 3” SW 2,999.00 3,938.00
11581 11585 HA4AS-80 Electric Shut Off Regulator 3” SW 3,950.00 5,085.00
11601 11605 HA4AB-20 Electric Wide Opening Regulator 3/8” SW 1,224.00 1,530.00
11621 11625 HA4AB-25 Electric Wide Opening Reg 1” SW 1,420.00 1,726.00
11634 11638 HA4AB-32 Electric Wide Opening Reg 1 1/4” SW 1,672.00 2,016.00
11648 11659 HA4AB-40 Electric Wide Opening Reg 1 1/2” SW 2,169.00 2,843.00
11662 11666 HA4AB-50 Electric Wide Opening Reg 2” SW 2,412.00 3,086.00
11670 11675 HA4AB-65 Electric Wide Opening Reg 21/2” SW 2,997.00 3,936.00
11676 11680 HA4AB-80 Electric Wide Opening Reg 3” SW 3,946.00 5,081.00
11696 11700 HA4AD-20 Dual Pressure Regulator 3/8” SW 1,696.00 2,002.00
11716 11720 HA4AD-25 Dual Pressure Regulator 1” SW 1,887.00 2,193.00
11729 11733 HA4AD-32 Dual Pressure Regulator 1 1/4” SW 2,142.00 2,486.00
11743 11747 HA4AD-40 Dual Pressure Regulator 1 1/2” SW 2,638.00 3,313.00
11757 11761 HA4AD-50 Dual Pressure Regulator 2” SW 2,881.00 3,556.00
11765 11768 HA4AD-65 Dual Pressure Regulator 3” SW 3,465.00 4,405.00
11771 11775 HA4AD-80 Dual Pressure Regulator 3” SW 4,416.00 5,551.00
11822 - HA2BK-15 Reseating Relief 1/2" SW 553.00 -
14055 - HA4AK(A)-20 Reseating Relief 1” SW 754.00 -
17094 - HA4AK(A)-25 Reseating Relief 1” SW 948.00 -
17095 - HA4AK(B)-32 Reseating Relief 11/4” SW 1,201.00 -
HA4A HA4ABHA2B
IN178
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
SOLENOID VALVES
Hansen Solenoid Valves - Lower CapacityRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
10925 10929 HS6-4 Pilot Operated Solenoid 3/8" SW 388.00 492.00
13936 10953 HS8A-13 Pilot Operated Solenoid 1/2” SW 461.00 564.00
10965 10969 HS8A-13 Pilot Operated Solenoid 3/4SW 461.00 564.00
10973 10977 HS7-20 Pilot Operated Solenoid 3/4 SW 572.00 842.00
11033 11037 HS7-25 Pilot Operated Solenoid 1” SW 832.00 1,102.00
11075 11079 HS7-32 Pilot Operated Solenoid 11/4”SW 1,027.00 1,297.00
Hansen Solenoid Valves - Higher CapacityRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
11105 11109 HS4A-20 Pilot Operated Solenoid 3/8” SW 712.00 982.00
11165 11169 HS4A-25 Pilot Operated Solenoid 1” SW 922.00 1,192.00
11207 11211 HS4A-32 Pilot Operated Solenoid 1 1/4” SW 1,115.00 1,386.00
11237 11241 HS4A-40 Pilot Operated Solenoid 1 1/2” SW 1,564.00 2,161.00
11279 11283 HS4A-50 Pilot Operated Solenoid 2” SW 1,714.00 2,616.00
11303 11307 HS4A-65 Pilot Operated Solenoid 2 1/2” SW 2,670.00 3,610.00
11345 11349 HS4A-80 Pilot Operated Solenoid 3” SW 3,877.00 5,011.00
Hansen Features & Selection
• All Hansen valves are spring closing and have Teflon seats.
• Safe Working Pressure 2758 kPag (400 psig)
• MOPD 2068 kPag (300 psig)
• Operating Temperature -50°C to +115°C (-60°F to +240°F)
• Suitable for ammonia, Carbon Dioxide, HCFCs, HFAs, and other approved refrigerants. For special duties such as Carbon Dioxide, please contact Realcold Ltd.
• All valves supplied with 230V 50 Hz coil, complete with DIN plug. Coils are also available in 115VAC, 24VAC and 24VDC and can be changed for a nominal charge of $15.00 per coil. For non-DIN coils and Conduit Fitting coils please refer to Realcold.
• All valves supplied as standard with Socket Weld (SW) flanges to suit Carbon Steel ASTM A106 or API line pipe. Can also be supplied with Weld Neck, FPT (Female Pipe Thread) or ODS connections to suit Copper Pipe. Flanges may be sized slightly larger or smaller than the valves dependent on application.
• Strainers, either close coupled or separate, are available - see page IN175
IN179
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
PRESSURE RELIEF, GAUGE & TRANSDUCER VALVES
Hansen Steel Pressure Relief ValvesRealcoldStock No.
Model Size Connections Pressure Settings Cap Ratingslbs Air/Minute
System Price$ Excl. GST
Inlet Outlet PSI kPa
12821 H5601 1/2" FPT 1" FPT 150 1034 35.8 312.00
12827 H5613 1" FPT 1.1/4" FPT 150 1034 53 659.00
12830 H5604 1.1/4" FPT 1.1/2" FPT 150 1034 72 1,219.00
12822 H5601 1/2" FPT 1" FPT 250 1725 57.7 312.00
12828 H5613 1" FPT 1.1/4" FPT 250 1725 85.4 659.00
12831 H5604 1.1/4" FPT 1.1/2" FPT 250 1725 116.1 1,219.00
12823 H5601 1/2" FPT 1" FPT 300 2070 - 312.00
12829 H5613 1" FPT 1.1/4" FPT 300 2070 - 659.00
12832 H5604 1.1/4" FPT 1.1/2" FPT 300 2070 - 1,219.00
Gauge Valves, AngleRealcoldStock No.
Description System Price$ Excl. GST
Hansen
11793 Hansen HGV1 Gauge Valve 1/4" MPT long neck screwed male and female 83.45
12780 Hansen H7771 Gauge Valve1/4" MPT Screwed male and female C/W Seal cap 84.50
12783 Hansen H7773 Gauge Valve 3/8" MPT Screwed male and female C/W Seal cap 96.85
12784 Hansen H7774 Gauge Valve 3/8" FPT Screwed female C/W Seal cap 95.80
Henry
19561 Henry 7773 Gauge Valve 3/8" NPT Screwed male and female 143.00
19571 Henry 7771 Gauge Valve 1/4" NPT Screwed male and female 92.70
17694 Henry 7775 Gauge Valve 1/2" NPT Screwed male and female 167.00
Transducer Valves Hansen & HenryRealcoldStock No.
Description System Price$ Excl. GST
12779 Hansen H9490 Transducer Valve; 8 mm (1/4in) MPT Inlet x FPT Gauge Port x FPT Transducer Port; With Seal Cap
129.00
Three Way Hand Shut-Off ValvesRealcoldStock No.
Description System Price$ Excl. GST
12833 Hansen H8021 Steel 1/2" FPT 326.00
12835 Hansen H8024 Steel 1" FPT 543.00
12836 Hansen H8025 Steel 1 1/4" FPT 758.00
Industrial Pressure GaugesRealcoldStock No.
Description Scale System Price$ Excl. GST
17700 63 mm -100 to + 1000 kPa 1/4" NPT LP Gauge 204.00
17701 63 mm -100 to + 2400 kPa 1/4" NPT HP Gauge 204.00
17702 100 mm -100 to + 900 kPa 1/4" NPT LP Gauge 403.00
17703 100 mm -100 to + 2400 kPa 1/4" NPT HP Gauge 403.00
11791 Hansen Ammonia Gauge GA1M -1 to 11 Bar 217.00
11792 Hansen Ammonia Gauge GA2M 01 to 21 Bar 217.00
Note: Stainless steel case, stainless steel Bourdon tube, glycerine filled, with kPa and temperature scales
IN180
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
FLOAT CONTROLS, LEVEL PROBES & SWITCHES, SIGHT GLASSES
Hansen Float Controls (See Spares Section for Spare Switch only)
RealcoldStock No.
Model Description System Price$ Excl. GST
12874 HLLE Float Switch Assembly 3/4” FPT/1” Butt Weld 1,270.00
Hansen Techni-Level® Level Transducer ProbesRealcoldStock No.
Model Description System Price$ Excl. GST
12916 VLT-04 Active Probe Length 1020 mm 3,175.00
12917 VLT-06 Active Probe Length 1525 mm 3,389.00
12918 VLT-08 Active Probe Length 2030 mm 3,691.00
12919 VLT-10 Active Probe Length 2540 mm 4,108.00
12913 VLT-XX Active Probe Length Cut to Suit Custom Length POA
Henry Liquid Level SwitchRealcoldStock No.
Model Description System Price$ Excl. GST
17695 Henry 9420-1 1 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Closed
380.00
17696 Henry 9420A-1 1 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Open
380.00
17925 Henry 9420 1/2 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Closed
281.00
19614 Henry 9420-1 1/2 inch Liquid Level Switch 208/240 V 50/60HZ; .25 amp resistive rating Normally Open
272.00
Industrial Sight Glasses - Steel*RealcoldStock No.
Model Description System Price$ Excl. GST
12321 Phillips 1100-R Level Eye Assembly, Bulls-Eye Lens (50 mm long housing) 247.00
12336 Phillips 1100 Level Eye Assembly, Clear Lens (50 mm long housing) 274.00
12947 Hansen H1100-R See-Level Assembly (82.5 mm long universal housing) 242.00
12948 Hansen H1100-RN See-Level Assembly (82.5 mm long universal housing) C/W Frost Shield
290.00
17200 Phillips 1101 Clear Lens 137.00
17311 Phillips 1101-R Bulls-Eye Lens 110.00
17310 Phillips 1105L Long Frost Shield (c/w 1106 'O' ring) 128.00
17546 Phillips 1103 Gasket 4.15
17547 Phillips 1104 Gasket 4.15
17052 Phillips 1102 Retainer 187.00
19849 Hansen 77-1002 Bulls-Eye / Reflex Lens Kit including Gaskets 92.70
19851 Hansen 77-0487 Retainer ring 77.25
19023 Hansen 77-1003 Hansen Standard Frost Shield (c/w "O" Ring) 64.90
18053 AC & R SG1004 1/2" MPT Sight Glass - Clear 26.80
17548 AC & R SG1008 1" MPT Sight Glass - Clear 34.00
14011 AC & R SG1108 1" MPT Sight Glass - Reflex 34.00
17697 AC & R SG1208 1"MPT Sight Glass with Ball 49.45
17698 AC & R SG1212 1 1/2"MPT Sight Glass with Ball 106.00
17549 AC & R SG1016 2" MPT Sight Glass - Clear 134.00
19562 Henry LI48A 1/2 Double Port Indicator 1/2” (15 mm) FPT 163.00
19563 Henry LI48A 3/4 Double Port Indicator 3/4” (20 mm) FPT 168.00
19564 Henry LI48A 1 Double Port Indicator 1” (25 mm) FPT 174.00
* Sight glasses not suitable for Ammonia Refrigeration Systems. Clear Lenses are not suitable for use with Ammonia. They may be used for Freon systems and Oil lines only. All lenses used for Ammonia must be of the Bulls Eye (RealFlex) type. If in doubt, please contact your local branch.
IN181
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
AUTO PURGERS
Hansen Mini Auto Purger NEAPAuto Purgers are available on Indent only. For selection and delivery please contact your local branch. Please specify model number, refrigerant and voltage.
RealcoldStock No.
Model Description System Price$ Excl. GST
Indent NEAP Mini Auto Purger - Ammonia 13,346.00
Indent VPM Valve Package Ammonia 1,884.00
Indent NEAPF Mini Auto Purger - Halocarbons 14,182.00
Indent VPMF Valve Package Halocarbons 3,068.00
Hansen Auto Purger APMRealcoldStock No.
Model Description System Price$ Excl. GST
Indent APM Auto Purger APM - 4-Points Ammonia 18,375.00
Indent VPM Valve Package Ammonia 1,664.00
Indent APMF Auto Purger APM - 4-Points Halocarbons 20,786.00
Indent VPMF Valve Package Halocarbons 3,068.00
Hansen Deluxe Auto Purger APMVarious additional options are available including Insulation, Water Conditioning Housing and Relief Valves. For details of the available options and for Halocarbon Refrigerant Auto-Purgers, please contact us.
RealcoldStock No.
Model Description System Price$ Excl. GST
Indent AP08 Auto Purger Deluxe - 8-Points 34,842.00
Indent AP16 Auto Purger Deluxe - 16-Points 39,779.00
Indent AP24 Auto Purger Deluxe - 24-Points 45,239.00
Hansen Plus Auto Purger APMSuitable for Ammonia Refrigeration Systems only.
RealcoldStock No.
Model Description System Price$ Excl. GST
Indent APP08 Auto Purger Plus - 8-Points 55,367.00
Indent APP16 Auto Purger Plus - 16-Points 61,540.00
Indent APP24 Auto Purger Plus - 24-Points 68,233.00
Mini Auto Purger NEAP
Auto Purger APP
Auto Purger AP
Auto Purger APM
IN182
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
AUTO PURGER SPARES
Hansen Auto Purger SparesRealcoldStock No.
Model Vendor Part No. Description System Price$ Excl. Gst
19766 AP 20-1198 Metering Valve Seal Kit 77.00
19765 AP 20-1214 Check Valve Seal Kit 46.00
19121 AP 20-1441 Power Element Level Control 1,617.00
19467 AP 20-1473 Counter 6-Digit 230V 1,383.00
19869 AP 20-1739 Power Element 230v 1,602.00
W99D83 AP 20-1772 Water Bubbler Assembly 558.00
19555 AP 20-1773 Purger Control Board Exc Connector 230V POA
19466 AP 70-0208 Liquid Line Solenoid Valve HS2 347.00
19767 AP HS2B-1 Solenoid Valve HS2 1/4" FPT 277.00
19870 AP - Level Control Flange Gaskets 16.50
W9209 APM 20-1836 Control Board 3,530.00
19656 APM 20-1857 Pressure Transducer 1,771.00
19879 APM 70-1068 Seal Orifice Kit for Solenoids B and C 92.00
19880 APM 70-1069 Seal Orifice Kit for Solenoid A 92.00
19417 APM 77-0534 High Side Level Sensor 1,161.00
18014 APM 77-0535 Level Sensor for Low side 861.00
19823 NEAP 20-1183 Check Valve 1PSID 484.00
60037 NEAP 20-1187 Check Valve Ball 12.00
19542 NEAP 20-1952 Metering Cartridge "O" Ring 9.00
19537 NEAP 20-2166 Float Ball Seat "O" Ring 15.00
19538 NEAP 20-2167 Vessel Cover "O" Ring 40.00
19825 NEAP 20-2199 Check Valve Assy 80 PSID 274.00
19539 NEAP 20-2200 Temperature Valve Assembly Kit 373.00
19824 NEAP 20-2200 Temperature Vavle Assy Kit 373.00
19535 NEAP 20-2201 Float Ball Plunger 256.00
19536 NEAP 20-2202 Float Ball Seat 268.00
19475 NEAP 20-2204 Check Valve Kit 225PSI 148.00
19826 NEAP 20-2207 Sight Glass 36.05
19543 NEAP 70-0065 Flange and Pilot Port Gasket 19.00
19541 NEAP 72-0066 NEAP Solenoid Tube Gasket 22.00
19915 NEAP 77-0036 Float Ball 185.00
19540 NEAP 78-1010 NEAP Strainer Kit 99.00
Note: Auto Purger Spares are available only as Indent Items. Price includes delivery via FedEx Courier. Parts are normally delivered within 5-10 working days from receipt of order. For a full list of available parts refer to the Hansen Collection of Instructions or refer to your local branch.
IN183
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
CHECK VALVES
Hansen Check Valves - AmmoniaRealcoldStock No.With Flanges or Butt Weld
RealcoldStock No.With Male Adaptor Ring
Description RealcoldStock No.
With Flanges or Butt Weld
RealcoldStock No.
With Male Adaptor Ring
Hansen HCK4 In-Line Check Valves - Ammonia
11964 11966 Hansen HCK4-2 15SW 232.00 197.00
11969 11970 Hansen HCK4-3 20SW 263.00 209.00
11972 11973 Hansen HCK4-4 25SW 325.00 270.00
11975 11977 Hansen HCK4-5 32SW 451.00 396.00
11978 - Hansen HCK4-6 32SW 363.00 -
11981 11982 Hansen HCK4-7 40SW 590.00 506.00
11984 11986 Hansen HCK4-8 50SW 659.00 576.00
11990 11991 Hansen HCK4-9 65SW 973.00 793.00
11993 11995 Hansen HCK4-0 80SW 1,259.00 1,046.00
11999 12001 Hansen HCK4-1 100SW 2,032.00 1,696.00
Hansen Hck1 Piston Check Valves - Ammonia
12005 Hansen HCK1-20 20SW 573.00
12009 Hansen HCK1-25 25SW 604.00
12013 Hansen HCK1-32 32SW 872.00
12017 Hansen HCK1-40 40SW 1,137.00
12021 Hansen HCK1-50 50SW 1,219.00
12025 Hansen HCK1-65 65SW 1,575.00
12029 Hansen HCK1-80 80SW 2,180.00
12033 Hansen HCK1-100 100SW 3,373.00
12037 Hansen HCK1W-125 BW PISTON CHK 6,092.00
12038 Hansen HCK1W-150 BW PISTON CHK 10,117.00
Modentic Wafer Duo Check Valves - AmmoniaDual Plate Check Valve; Mv-1221 ANSI 150 or 300lbs; Body & Disc CF8M; Plate S/S 316. ANSI150lb Valves come with Metal to Metal Seat. The 300lb Valves come with Neoprene seat with chemical resistance to Liquid and Gaseous Ammonia and mineral refrigerant oils at the normal temperatures experienced in industrial refrigeration. For other refrigerants and oil combinations, please refer to your local branch.
RealcoldStock No.
Description System Price$ Excl. Gst
19445 Modentic 50NB CHK VLV ANSI150 POA
19446 Modentic 65NB CHK VLV ANSI150 POA
19447 Modentic 80NB CHK VLV ANSI150 POA
19448 Modentic 100NB CHK VLV ANSI150 POA
19449 Modentic 125NB CHK VLV ANSI150 POA
19450 Modentic 150NB CHK VLV ANSI150 POA
19451 Modentic 200NB CHK VLV ANSI150 POA
19452 Modentic 250NB CHK VLV ANSI150 POA
19453 Modentic 300NB CHK VLV ANSI150 POA
19454 Modentic 50NB CHK VLV ANSI300 POA
19455 Modentic 65NB CHK VLV ANSI300 POA
19456 Modentic 80NB CHK VLV ANSI300 POA
19457 Modentic 100NB CHK VLV ANSI300 POA
19458 Modentic 125NB CHK VLV ANSI300 POA
19459 Modentic 150NB CHK VLV ANSI300 POA
19460 Modentic 200NB CHK VLV ANSI300 POA
19461 Modentic 250NB CHK VLV ANSI300 POA
19462 Modentic 300NB CHK VLV ANSI300 POA
IN184
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
MULTI PORT VALVES
Hansen Multi Port Valves Sample Configurations for Common Valve ApplicationsThe Hansen MVP Multi Valve Platform is well suited for multiple applications including Pumped Liquid Feed, liquid make-up to flooded and recirculation vessels, liquid injection for compressors, hot-gas defrost to evaporators, and evaporator pressure control. Up to six functions are possible: stop, strainer, control valve (solenoid / pressure regulator / motorised valve), check, hand expansion and stop all in one dynamic multi-solution valve. See the Hansen MVP Multi Valve Platform brochure for more information.
Application Position 1 Position 2 Position 3 Position 4
Liquid Feed Shut-Off Strainer Solenoid Stop Check/Hex
Liquid Feed, Motorized Shut-Off Strainer Motor Stop Check/Hex
Liquid Make-Up Shut-Off Strainer Solenoid Hand Expansion
Liquid Make-Up, Motorized Shut-Off Strainer Motor Shut-Off
Hot Gas Valve Shut-Off Strainer Solenoid Shut-Off
Hot Gas Valve, Motorized Shut-Off Strainer Motor Shut-Off
Defrost Relief Shut-Off Strainer Regulator Shut-Off
Defrost Relief/Wide Open Shut-Off Strainer Regulator Shut-Off
MVP with Solenoid Control ValveSIZE Port SW
ConnectionModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. Gst
MVP20 3/4" 3/4" MVP-1 1,546.00 MVP-2 1,556.00 MVP-3 1,767.00 MVP-4 1,757.00 MVP-5 1,521.00
1" MVP-1 1,600.00 MVP-2 1,639.00 MVP-3 1,850.00 MVP-4 1,811.00 MVP-5 1,548.00
1-1/4" MVP-1 1,798.00 MVP-2 1,816.00 MVP-3 2,027.00 MVP-4 2,009.00 MVP-5 1,647.00
MVP25 1" 1" MVP-1 1,833.00 MVP-2 1,872.00 MVP-3 2,142.00 MVP-4 2,102.00 MVP-5 1,839.00
1-1/4" MVP-1 2,031.00 MVP-2 2,049.00 MVP-3 2,318.00 MVP-4 2,301.00 MVP-5 1,939.00
MVP32 1-1/4" 1-1/4" MVP-1 2,246.00 MVP-2 2,263.00 MVP-3 2,649.00 MVP-4 2,631.00 MVP-5 2,269.00
MVP40 1-1/2" 1-1/2" MVP-1 3,392.00 MVP-2 3,469.00 MVP-3 3,965.00 MVP-4 3,888.00 MVP-5 3,381.00
2" MVP-1 3,550.00 MVP-2 3,625.00 MVP-3 4,121.00 MVP-4 4,046.00 MVP-5 3,460.00
2-1/2" MVP-1 3,953.00 MVP-2 4,231.00 MVP-3 4,727.00 MVP-4 4,449.00 MVP-5 3,661.00
MVP50 2" 2" MVP-1 3,720.00 MVP-2 3,795.00 MVP-3 4,359.00 MVP-4 4,283.00 MVP-5 3,698.00
2-1/2" MVP-1 4,123.00 MVP-2 4,401.00 MVP-3 4,965.00 MVP-4 4,686.00 MVP-5 3,899.00
MVP with Pressure Regulator Control ValveSIZE Port SW
ConnectionModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. GstModel System Price
$ Excl. Gst
MVP20 3/4" 3/4" MVP-1A 1,139.00 MVP-2A 1,146.00 MVP-3A 1,315.00 MVP-4A 1,308.00 MVP-5A 1,119.00
1" MVP-1A 1,182.00 MVP-2A 1,213.00 MVP-3A 1,382.00 MVP-4A 1,351.00 MVP-5A 1,140.00
1-1/4" MVP-1A 1,340.00 MVP-2A 1,354.00 MVP-3A 1,523.00 MVP-4A 1,509.00 MVP-5A 1,219.00
MVP25 1" 1" MVP-1A 1,334.00 MVP-2A 1,366.00 MVP-3A 1,581.00 MVP-4A 1,550.00 MVP-5A 1,339.00
1-1/4" MVP-1A 1,493.00 MVP-2A 1,507.00 MVP-3A 1,722.00 MVP-4A 1,708.00 MVP-5A 1,419.00
MVP32 1-1/4" 1-1/4" MVP-1A 1,692.00 MVP-2A 1,706.00 MVP-3A 2,014.00 MVP-4A 2,001.00 MVP-5A 1,711.00
MVP40 1-1/2" 1-1/2" MVP-1A 2,603.00 MVP-2A 2,664.00 MVP-3A 3,061.00 MVP-4A 3,000.00 MVP-5A 2,594.00
2" MVP-1A 2,729.00 MVP-2A 2,789.00 MVP-3A 3,186.00 MVP-4A 3,126.00 MVP-5A 2,657.00
2-1/2" MVP-1A 3,051.00 MVP-2A 3,274.00 MVP-3A 3,671.00 MVP-4A 3,448.00 MVP-5A 2,818.00
MVP50 2" 2" MVP-1A 2,918.00 MVP-2A 2,978.00 MVP-3A 3,429.00 MVP-4A 3,369.00 MVP-5A 2,900.00
2-1/2" MVP-1A 3,240.00 MVP-2A 3,463.00 MVP-3A 3,914.00 MVP-4A 3,691.00 MVP-5A 3,061.00
IN185
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
MOTORISED VALVES
Hansen Motorised Valves - Model HMSVSuitable for pressure, temperature, or level control. Drop-in replacement for same port size Hansen valve. Model HMSV: The full ported valve series is best suited for applications requiring slow open/close operation only.
Less Strainer with Flanges Nominal Size
Flow Factor (CV)
Standard, System Price$ Excl. Gst
Power Close, System Price$ Excl. Gst
Hansen HMSV Motorised Valve 20 mm 20 mm 6.4 4,543.00 6,097.00 Hansen HMSV Motorised Valve 25 mm 25 mm 11.7 4,738.00 6,291.00 Hansen HMSV Motorised Valve 32 mm 32 mm 16.4 4,997.00 6,550.00 Hansen HMSV Motorised Valve 40 mm 40 mm 33 5,490.00 7,043.00 Hansen HMSV Motorised Valve 50 mm 50 mm 47 5,745.00 7,298.00 Hansen HMSV Motorised Valve 80 mm 80 mm 104 8,190.00 9,743.00 Hansen HMSV Motorised Valve 100 mm 100 mm 166 10,871.00 12,424.00
Hansen Motorised Valves - Model HMMRModel HMMR: Valve series with expansion plug is for high pressure drop applications such as liquid makeup and liquid injection. Can also be used in the same application as model HMMV valves where reduced capacities or larger line size connections are required. VPIF standard.
Less Strainer with Flanges Nominal Size
Flow Factor (CV)
Standard, System Price$ Excl. Gst
Power Close, System Price$ Excl. Gst
Hansen HMMR Motorised Valve 20 mm 20 mm 2.2 5,185.00 6,719.00 Hansen HMMR Motorised Valve 25 mm 25 mm 3.9 5,382.00 6,935.00 Hansen HMMR Motorised Valve 32 mm 32 mm 5.5 5,639.00 7,192.00 Hansen HMMR Motorised Valve 40 mm 40 mm 12 6,133.00 7,687.00 Hansen HMMR Motorised Valve 50 mm 50 mm 16 6,388.00 7,942.00 Hansen HMMR Motorised Valve 80 mm 80 mm 35 8,834.00 10,387.00 Hansen HMMR Motorised Valve 100 mm 100 mm 55 11,513.00 13,066.00
Hansen Motorised Valves - Model HMMVModel HMMV: Valve series is best suited for computer controlled operations using 4-20 mA signals. Ideal for precise temperature and pressure control, hot gas defrost, and other applications where accurate process control is required. VPIF standard.
Less Strainer with Flanges Nominal Size
Flow Factor (CV)
Standard, System Price$ Excl. Gst
Power Close, System Price$ Excl. Gst
Hansen HMMV Motorised Valve 20 mm 20 mm 6.4 5,185.00 6,719.00 Hansen HMMV Motorised Valve 25 mm 25 mm 11.7 5,382.00 6,935.00 Hansen HMMV Motorised Valve 32 mm 32 mm 16.4 5,639.00 7,192.00 Hansen HMMV Motorised Valve 40 mm 40 mm 35 6,133.00 7,687.00 Hansen HMMV Motorised Valve 50 mm 50 mm 47 6,388.00 7,942.00 Hansen HMMV Motorised Valve 80 mm 80 mm 104 8,834.00 10,387.00 Hansen HMMV Motorised Valve 100 mm 100 mm 166 11,513.00 13,066.00
Hansen Motorised Valves - Model HMXVModel HMXV: Valve series for precise liquid metering for direct expansion or liquid feed applications.
Less Strainer with Flanges Nominal Size
Flow Factor (CV)
Standard, System Price$ Excl. Gst
Power Close, System Price$ Excl. Gst
Hansen HMXV Motorised Valve 5 mm 5 mm 0.6 5,187.00 6,740.00 Hansen HMXV Motorised Valve 7 mm 7 mm 1.1 5,187.00 6,740.00
Hansen Motorised Valves - Motorised Valve AccessoriesModel System Price
$ Excl. Gst
HANSEN Valve Poistion Indicator 1,013.00 HANSEN VPIF Extension Cable 413.00 POWER Transformer 115/230/24V 328.00 POWERT Control I/Face HMSV 1,683.00 HANSEN Valve Opening Tool 488.00 HANSEN Calibration Key 28.00
IN186
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
2-STEP SOLENOID, SUCTION STOP & OIL CHANGE VALVES
Hansen HS4D - 2-Step Dual Solenoid ValvesRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
19737 19745 HS4D-20 2-Step Dual Solenoid Valve 3/4” SW 1,785.00 2,091.00
19738 19746 HS4D-25 2-Step Dual Solenoid Valve 1” SW 1,827.00 2,133.00
19739 19747 HS4D-32 2-Step Dual Solenoid Valve 11/4” SW 1,917.00 2,223.00
19740 19748 HS4D-40 2-Step Dual Solenoid Valve 11/2” SW 2,420.00 2,726.00
19741 19749 HS4D-50 2-Step Dual Solenoid Valve 2” SW 2,769.00 3,444.00
19742 19750 HS4D-65 2-Step Dual Solenoid Valve 2 1/1” SW 3,403.00 4,342.00
19743 19751 HS4D-80 2-Step Dual Solenoid Valve 3” SW 4,848.00 5,983.00
19744 19752 HS4D-100 2-Step Dual Solenoid Valve 4” SW 6,419.00 8,667.00
Hansen HCK5D - 2-Step Gas Powered Suction Stop ValvesRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
19753 19758 HCK5D-40 2-Step Suction Stop Valve 11/2” SW 2,167.00 2,620.00
19754 19759 HCK5D-50 2-Step Suction Stop Valve 2” SW 2,300.00 2,754.00
19755 19760 HCK5D-65 2-Step Suction Stop Valve 2 1/2” SW 2,825.00 3,278.00
19756 19761 HCK5D-80 2-Step Suction Stop Valve 3” SW 3,274.00 3,727.00
19757 19762 HCK5D-100 2-Step Suction Stop Valve 4” SW 4,907.00 5,361.00
Note: Hansen 2-Step Solenoid & Stop Valves Indent Only
Hansen Oil Drain ValvesRealcoldStock No.
Model Description System Price$ Excl. GST
17745 Hansen 50-2644 Apollo Oil Drain Valve 15 mm 301.00
17437 Hansen 50-2645 Apollo Oil Drain Valve 20 mm 372.00
IN187
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
Hansen HS4D - 2-Step Dual Solenoid ValvesRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
19737 19745 HS4D-20 2-Step Dual Solenoid Valve 3/4” SW 1,785.00 2,091.00
19738 19746 HS4D-25 2-Step Dual Solenoid Valve 1” SW 1,827.00 2,133.00
19739 19747 HS4D-32 2-Step Dual Solenoid Valve 11/4” SW 1,917.00 2,223.00
19740 19748 HS4D-40 2-Step Dual Solenoid Valve 11/2” SW 2,420.00 2,726.00
19741 19749 HS4D-50 2-Step Dual Solenoid Valve 2” SW 2,769.00 3,444.00
19742 19750 HS4D-65 2-Step Dual Solenoid Valve 2 1/1” SW 3,403.00 4,342.00
19743 19751 HS4D-80 2-Step Dual Solenoid Valve 3” SW 4,848.00 5,983.00
19744 19752 HS4D-100 2-Step Dual Solenoid Valve 4” SW 6,419.00 8,667.00
Hansen HCK5D - 2-Step Gas Powered Suction Stop ValvesRealcoldStock No.Without Strainer
RealcoldStock No.With Strainer
Description System Price$ Excl. GST
Without Strainer
System Price$ Excl. GST
With StrainerValve Flange Size
19753 19758 HCK5D-40 2-Step Suction Stop Valve 11/2” SW 2,167.00 2,620.00
19754 19759 HCK5D-50 2-Step Suction Stop Valve 2” SW 2,300.00 2,754.00
19755 19760 HCK5D-65 2-Step Suction Stop Valve 2 1/2” SW 2,825.00 3,278.00
19756 19761 HCK5D-80 2-Step Suction Stop Valve 3” SW 3,274.00 3,727.00
19757 19762 HCK5D-100 2-Step Suction Stop Valve 4” SW 4,907.00 5,361.00
Note: Hansen 2-Step Solenoid & Stop Valves Indent Only
AMMONIA & OTHER GAS SENSORS
Hansen Gas SensorsRealcoldStock No.
Model Description System Price$ Excl. GST
19526 HEC4-N100 Hansen HEC4-N100 Ammonia Sensor 2,332.00
19527 HEC4-N250 Hansen HEC4-N250 Ammonia Sensor 2,332.00
19528 HEC4-N1K Hansen HEC4-N1K Ammonia Sensor 2,332.00
19529 HSC4-N10K Hansen HSC4-N10K Semi-Conductor Ammonia Sensor 1,601.00
19657 HSC1-F3K-R22 Hansen HSC1-F3k Halogen R22 Basic Sensor 954.00
19658 HSC1-F3K-R507 Hansen HSC1-F3k Halogen R507 Basic Sensor 954.00
19659 HSC1-F3K-R134 Hansen HSC1-F3k Halogen R134a Basic Sensor 954.00
19660 HSC1-F3K-R404 Hansen HSC1-F3k Halogen R404 Basic Sensor 954.00
19661 HSC1-F3K-R410 Hansen HSC1-F3k Halogen R410 Basic Sensor 954.00
19663 HSC4H-F3K-R22 Hansen HSC4h-F3k Halogen R22 Harsh Sensor 1,808.00
19664 HSC4H-F3K-R507 Hansen HSC4h-F3k Halogen R507 Harsh Sensor 1,808.00
19665 HSC4H-F3K-R134 Hansen HSC4h-F3k Halogen R134a Harsh Sensor 1,808.00
19666 HSC4H-F3K-R404 Hansen HSC4h-F3k Halogen R404 Harsh Sensor 1,808.00
19667 HSC4H-F3K-R410 Hansen HSC4h-F3k Halogen R410 Harsh Sensor 1,808.00
19668 HSC4E-F3K-R22 Hansen HSC4E-F3K Halogen R22 Extreme Sensor 3,199.00
19669 HSC4E-F3K-R507 Hansen HSC4E-F3K Halogen R507 Extreme Sensor 3,199.00
19670 HSC4E-F3K-R134 Hansen HSC4E-F3K Halogen R134a Extreme Sensor 3,199.00
19671 HSC4E-F3K-R404 Hansen HSC4E-F3K Halogen R404 Extreme Sensor 3,199.00
19672 HSC4E-F3K-R410 Hansen HSC4E-F3K Halogen R410 Extreme Sensor 3,199.00
19673 HEC4H-N100 Hansen HEC4H-N100 Ammonia Harsh Sensor 3,168.00
19674 HEC4H-N1250 Hansen HEC4H-N250 Ammonia Harsh Sensor 3,168.00
19675 HEC4H-N1K Hansen HEC4H-N1K Ammonia Harsh Sensor 3,168.00
19676 HSC4H-N10K Hansen HEC4H-N10K Ammonia Harsh Sensor 2,291.00
19677 HEC4E-N100 Hansen HSC4E-N100 Ammonia Extreme Sensor 4,075.00
19678 HEC4E-N250 Hansen HEC4E-N250 Ammonia Extreme Sensor 4,075.00
19679 HEC4E-N1K Hansen HEC4E-N1K Ammonia Extreme Sensor 4,075.00
19680 HSC4E-N10K Hansen HSC4E-N1K Ammonia Extreme Sensor 3,199.00
19681 HIR1-C10K Hansen HIR1-C10K Carbon Dioxide Basic Sensor 1,675.00
19682 HIR4H-C10K Hansen HIR4H-C10K Carbon Dioxide Harsh Sensor 2,291.00
19683 HIR4E-C10K Hansen HIR4E-C10K Carbon Dioxide Extreme Sensor 3,199.00
19684 HVSC4-F5K Hansen HVSC4-F5k R22 Vent Sensor (Specify Refrigerant) 2,395.00
19685 HVSC4-N10K Hansen HVSC4-N10K Ammonia Vent Sensor 2,516.00
19686 GAS-100 Hansen Gas 100 Alert System 3,464.00
19687 GAS-250 Hansen Gas 250 Alert System 3,464.00
19688 GAS-1K Hansen Gas 1K Alert System 3,464.00
19689 GAS-10K Hansen Gas 10K Alert System 3,464.00
19690 31-1002 Hansen Sensor Element Shield 93.75
19691 31-1001 Hansen Sensor c/w DIN Quick Connect Plug 353.00
19692 31-1011 Hansen Portable Gas Detector 4,447.00
19693 31-1012 Hansen Sensor Module 0-50-500 PPM 1,407.00
19694 31-1013 Hansen Sensor Module 0-500-2000P:PM 1,811.00
19719 HLM6 Hansen 6-Channel Gas Monitor 2,366.00
Note: Leak detectors can be found on page CT136.
Basic
Explosion Proof
Gas Vent Line
Harsh Environment
IN188
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
REFRIGERANT PUMPS
Hermetic Pumpen Pump Range - Individual Bare PumpsRealcoldStock No.
Description Motor Size
15372 CAM 1/2 AGX 1.0
15373 CAM 1/3 AGX 1.0
15374 CAM 1/4 AGX 1.0
15375 CAM 1/5 AGX 1.0
15376 CAM 2/2 AGX 3.0
15377 CAM 2/2 AGX 4.5
15378 CAM 2/3 AGX 3.0
15379 CAM 2/3 AGX 4.5
15380 CAM 2/4 AGX 3.0
15381 CAM 2/4 AGX 4.5
15382 CAM 2/5 AGX 3.0
15383 CAM 2/5 AGX 4.5
15384 CAM 2/5 AGX 6.5
15385 CAM 2/6 AGX 3.0
15386 CAM 2/6 AGX 4.5
15387 CAM 2/6 AGX 6.5
15388 CAMR 2/2 AGX 3.0
15389 CAMR 2/2 AGX 4.5
15390 CAMR 2/3 AGX 3.0
15391 CAMR 2/3 AGX 4.5
15392 CAMR 2/4 AGX 3.0
15393 CAMR 2/4 AGX 4.5
15394 CAMR 2/5 AGX 3.0
15395 CAMR 2/5 AGX 4.5
15396 CAMR 2/5 AGX 6.5
15397 CAMR 2/6 AGX 3.0
15398 CAMR 2/6 AGX 4.5
15399 CAMR 2/6 AGX 6.5
15400 CAM 3/2 AGX 8.5
15401 CAM 3/2 CKPX 12.0
15402 CAM 3/2 CKPX 64 R-2
15403 CAM 3/3 CKPX 8.5
15404 CAM 3/3 CKPX 12.0
15405 CAM 3/3 CKPX 64 R-2
15406 CAM 3/4 CKPX 12.0
15407 CAM 3/4 CKPX 64 R-2
15408 CNF 40-160 AGX 3.0
15409 CNF 40-160 AGX 4.5
15410 CNF 40-160 AGX 6.5
15411 CNF 40-160 AGX 8.5
15412 CNF 40-200 AGX 4.5
15413 CNF 40-200 AGX 6.5
15414 CNF 40-200 AGX 8.5
15415 CNF 40-200 CKPX 12.0
15416 CNF 50-160 AGX 4.5
15417 CNF 50-160 AGX 6.5
15418 CNF 50-160 AGX 8.5
15419 CNF 50-160 CKPX 12.0
15420 CNF 50-200 AGX 6.5
15421 CNF 50-200 AGX 8.5
15422 CNF 50-200 CKPX 12.0
CAM 2/3
CAMR 2/3
CNF 40-160
IN189
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
REFRIGERANT PUMP ACCESSORIES
Hermetic Pumpen - Pump AccessoriesRealcoldStock No.
Description System Price$ Excl. Gst
15423 Hermetic Qmin Orifice Dn20 26.80
15424 Hermetic Qmin Orifice Dn25 26.80
15425 Hermetic Qmin Orifice Dn32 26.80
15426 Hermetic Qmax Orifice Dn32 26.80
15427 Hermetic Qmax Orifice Dn40 229.00
15428 Hermetic Qmax Orifice Dn50 260.00
15429 Hermetic CAM1 Pump Flange Set 159.00
15430 Hermetic CAM2 Pump Flange Set 198.00
17008 Hermetic CAMR 2 Pump Flange Set 225.00
15431 Hermetic CAM3 Pump Flange Set 233.00
15432 Hermetic CNF50 Pump Flange Set 264.00
15433 Hermetic Dn20 M/F Flange Set 150.00
15434 Hermetic Dn25 M/F Flange Set 159.00
15435 Hermetic Dn32 M/F Flange Set 185.00
15436 Hermetic Dn40 M/F Flange Set 220.00
15437 Hermetic Dn50 M/F Flange Set 247.00
15438 Hermetic AGX1/3/4.5 Base Plate 514.00
15439 Hermetic AGX 8.5 Base Plate 1,289.00
15440 Hermetic Ckpx 12.0 Base Plate 1,640.00
15441 Hermetic Ckpx 64r-2 Base Plate 2,089.00
15442 Hermetic Ql-61-44-8 Flow Regulator 774.00
15443 Hermetic Ql-62-85-8 Flow Regulator 1,750.00
15444 Hermetic Ql-62-110-8 Flow Regulator 1,750.00
15445 Hermetic Ql-61-150-8 Flow Regulator 1,750.00
15446 Hermetic Ql-62-85-8 Flow Regulator 1,750.00
15447 Hermetic Ql-62-110-8 Flow Regulator 1,750.00
15448 Hermetic Ql-61-150-8 Flow Regulator 1,750.00
15449 Hermetic Inducer 1,597.00
15450 Hermetic Thermistor Kl 170 594.00
15452 Hermetic Nitrogen Filling 782.00
15453 Hermetic Marine Cable 717.00
15454 Hermetic Small Pump Packing 136.00
15455 Hermetic Large Pump Packing 220.00
Notes on Ordering Hermetic Pumps & Accessories
• Costs of freight of Accessories are included in the cost of freight of the bare pump. Where accessories are ordered without pumps, we will calculate freight and other costs of delivery and add to the cost of the accessory.
• Small Pump Packing is chargeable on all base CAM 1 and 2 pumps.
• Large Pump Packing is chargeable on all CAM3 and CNF type Pumps.
• For Carbon Dioxide Pumps, you need to add the cost of Pressure Testing to 45 bar. Pumps for other refrigerants are available on request.
IN190
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
REFRIGERANT PUMP ACCESSORIES
Hermetic Pumpen - Pump AccessoriesRealcoldStock No.
Description System Price$ Excl. Gst
17711 Pump Gasket Set for CAM 2/4 142.00
17712 Pump Gasket Set for CAM 3/3 46.35
17714 Pump Gasket Set for CNF50-200 30.90
17715 Pump Gasket Set for CNF50-160 27.85
17716 Pump Gasket Set for CAM 1/4 36.60
17717 Motor Gasket Set for for AGX4.5 114.00
17718 Motor Gasket Set for for AGX8.5 25.25
17720 Motor Gasket Set for for AGX6.5 114.00
19570 Motor Gasket Set for AGX3.0 92.70
60071 Bearing Set AGx3.0 1,922.00
60072 Bearing Set AGx4.5 1,922.00
60073 Bearing Set AGx6.5 1,922.00
60074 Bearing Set AGx8.5 2,447.00
60075 Bearing Set CKPx12.0 2,902.00
14003 Stator Lining and Sealing Disc AGx3.0 474.00
W9322 Stator Lining and Sealing Disc AGx4.5/6.5 403.00
60076 Stator Lining and Sealing Disc AGx8.5 574.00
60077 Stator Lining and Sealing Disc CKPx12.0 789.00
IN191
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
VALVES - SOLENOID COILS
Hansen Solenoid CoilsRealcoldStock No.
Model Description System Price$ Excl. Gst
18061 70-1092 Hansen Solenoid Replacement Coil 115V 116.00
18062 70-1093 Hansen Solenoid Replacement Coil 230V 116.00
18063 70-1094 Hansen Solenoid Replacement Coil 24V AC 116.00
18064 70-1095 Hansen Solenoid Replacement Coil 24V DC 116.00
18068 70-0584 Hansen Solenoid Replacement Coil 115V 69.05
18069 70-0585 Hansen Solenoid Replacement Coil 230V 69.05
18070 70-0586 Hansen Solenoid Replacement Coil 24V AC 69.05
18071 70-0583 Hansen Solenoid Replacement Coil 24V DC 69.05
18065 70-1100 Hansen Beacon Pilot Light Kit Red 89.65
18066 70-1102 Hansen Beacon Pilot Light Kit Green 89.65
18067 70-1101 Hansen Beacon Pilot Light Kit Amber 89.65
Hansen Danvalve Solenoid Adaptor KitRealcoldStock No.
Model Description System Price$ Excl. Gst
19534 70-1104 Hansen to Danfoss Coil Conversion Kit
(Includes “O” Ring, Circlip and Fixing Cap)
31.95
Parker Ammonia Solenoid CoilsRealcoldStock No.
Model Description System Price$ Excl. Gst
19309 205226 Refspec Encapsulated Sol Coil 230V 50HZ 246.00
19311 207868 Refspec / Sporlan KSMA32 Sol Coil 230V 50HZ 239.00
19418 207608 Sporlan MKC3 Sol Coil 230V 50HZ 237.00
17307 205213 Refspec Encapsulated Sol Coil 24V DC 249.00
60056 311515 Sporlan MKC-2 Sol Coil 208-240V 50-60Hz 67.00
Hansen Solenoid Coils
• Hansen coils are Watertight Encapsulated Solenoid coils with no outside frame. All coils are normally
sold complete with DIN Plug Socket and come with “O” Ring and Knob. Normal Voltage available is
230V, however, 115V, 24V AC, 24V DC are also normally available ex-stock.
• Replacement Coils which do not include a Knob and Din Plug are also available in 300 mm Tailed
and Conduit style connections on request.
• Beacon Pilot Light Kits, to indicate when solenoids are operating are available on request. This kit
includes Beacon Pilot Knob and “O” Ring.
IN192
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
VALVES - SPARES
Valves - SparesRealcoldStock No.
Model Vendor Part No. Description System Price$ Excl. Gst
12869 LLSWE HLLSWE Switch Assembly, replacement, DIN plug included 656.00
17395 HS6, HS8 70-0065 Flange Gasket Suits Flange #50 15.45
17396 AR25-32 HS7 70-0132 Flange Gasket Suits Flange #100 15.45
17397 AR40-50 75-0138 Flange Gasket Suits Flange #200 15.45
17398 AR65 75-0125 Flange Gasket Suits Flange #250 15.45
17399 AR80 75-0137 Flange Gasket Suits Flange #300 21.65
17400 AR100 75-0253 Flange Gasket Suits Flange #400 35.05
17404 All Sol Valves 70-1052 Hansen MS Pilot Solenoid 195.00
17519 AR32 65-1023 V-Port Seat Kit 397.00
17520 AR40 75-1029 V-Port Seat Kit 417.00
17521 AR50 75-1030 V-Port Seat Kit 542.00
17522 AR100 75-1033 V-Port Seat Kit 715.00
17524 HCK2 75-1004 Piston Seat Kit 448.00
17525 AR100 75-1028 Piston Kit 940.00
17617 ST050 78-1001 Strainer Screen Kit 85.50
17618 ST100 78-1003 Strainer Screen Kit 177.00
18938 ST100 78-1013 Strainer Screen Kit Heavy Duty 236.00
18939 ST100 78-1014 Strainer Screen Kit Fine 100 Mesh 201.00
17619 ST200 78-1005 Strainer Screen Kit 250.00
17620 ST250 78-1007 Strainer Screen Kit 271.00
17622 ST050 78-0016 Strainer Cover Gasket 15.45
17623 ST100 78-0026 Strainer Cover Gasket 15.45
17624 ST200 75-0113 Strainer Cover Gasket 21.65
17625 ST250 75-0128 Strainer Cover Gasket 21.65
18940 ST100 78-1015 Strainer System Start Up Bag 82.40
18941 ST200 78-1016 Strainer System Start Up Bag 91.70
18942 ST250/300 78-1017 Strainer System Start Up Bag 111.00
18943 ST400 78-1018 Strainer System Start Up Bag 118.00
17627 HS6 70-1011 Gasket Kit 69.05
17628 HS8 70-1005 Gasket Kit 78.30
17629 HS7 70-1017 Gasket Kit 91.70
17632 HS8A 70-1001 Bonnet-Cartridge Kit 410.00
17633 HS7 70-1018 Bonnet-Cartridge Kit 542.00
19943 HS 70-0301 Hansen Solenoid Tube Gasket 6.20
17636 HS8 70-1002 Piston Assembly Kit 209.00
17637 HS7 - 3/4" 70-1019 Piston Assembly Kit 505.00
17638 HS7-25 70-1020 Piston Assembly Kit 505.00
17639 HS7-32 70-1021 Piston Assembly Kit 574.00
17642 HS6, HS7, HS8 70-1059 Solenoid Tube/Plunger Kit 227.00
17643 HS7 70-1022 Stem Kit 94.80
For more information on industrial products please call +64 (0)9 526 5955.
IN193
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Indu
stria
l
VALVES - SPARES
Valves - SparesRealcoldStock No.
Model Vendor Part No. Description System Price$ Excl. Gst
17647 AR20-32 75-1023 Gasket Kit 65.95
17648 AR40-50 75-1039 Gasket Kit 78.30
17649 AR65 75-1040 Gasket Kit 91.70
17650 AR80 75-1041 Gasket Kit 111.00
17651 AR100 75-1042 Gasket Kit 123.00
17654 AR20-32 75-1019 Piston Kit 325.00
17655 AR40-50 75-1025 Piston Kit 539.00
17656 AR65 75-1026 Piston Kit 684.00
17657 AR80 75-1027 Piston Kit 823.00
17660 AR20 75-1020 V-Port Seat Kit 274.00
17661 AR25 75-1021 V-Port/Seat Kit 369.00
17665 AR65 75-1031 V-Port Seat Kit 602.00
17666 AR80 75-1032 V-Port/Seat Kit 656.00
17670 AR Port 75-1071 Gasket Kit 15.45
17671 M30 M3,M3K 75-1108 Diaphragm/Gasket Kit 75.20
17699 Henry n/a Flange Gasket Suits 1 1/4 in Flange 7.25
19116 VLT 77-1004 VLT Digital Readout Kit 1,330.00
19127 HMMR 75-1154 V-Port Kit For HMMR 32 861.00
19128 HMMR 75-1148 Gasket Kit 20-32 mm HMMR 24.75
19129 HMMR 75-1150 Gasket Kit 40-50 mm HMMR 28.85
19130 HMMR 75-1151 Gasket Kit 80 mm HMMR 259.00
19131 HMMR 75-1167 Cartge Kit 20-32 mm HMMR 1,847.00
19132 HMMR 75-1168 Cartge Kit 40-50 mm HMMR 2,033.00
19133 HMMR 75-1171 Power Head for Kit Pwr SMV 5,670.00
19134 HMMR 75-1183 Pwr-Close Kit Pwr Head 7,869.00
19135 HMMR 75-1169 Cartridge Kit 80 mm HMMR 1,942.00
19136 HMMR 75-2922 Can Kit HMMR 533.00
19137 HMMR MOVT Manual Vlv Opening Tool 691.00
19138 HMMR 75-1185 Calibration Key HMMR 38.15
19139 HMMR 75-1149 Pilot Seat Kit 80 mm HMMR 262.00
19140 HMMR 75-1153 Pilot Seat Kit 100 mm HMMR 262.00
19141 HGV 50-1070 Gasket Kit 8 mm HGV 24.75
19142 H7773/4 50-1074 Gasket Kit 10 mm H7773/4 44.30
19143 Stop/H/Exp 50-1040 Gasket Kit 13-32 mm Vlv 53.60
19144 Stop/H/Exp 50-1023 Gasket Kit 40-50 mm Vlv 72.10
19145 Stop 50-1043 Gasket Kit 65-80 mm Vlv 75.20
19146 Stop 50-1065 Gasket Kit 100 mm Vlv 111.00
19147 Stop 50-1082 Gasket Kit 125 mm Vlv 132.00
19148 Stop 50-1083 Gasket Kit 150 mm Vlv 143.00
19533 Stop 50-1084 Gasket Kit 200 mm Ra Vlv 220.00
19308 HA2BK 75-1107 HA2BK Overhaul Kit 93.75
19935 Consumable - Phenol Pthalate Ammonia Test Paper 45.00
For more information on industrial products please call +64 (0)9 526 5955.
Cap
ital P
lant
Capital PlantL’unite Sealed CP196
Drawings CP197R404a Medium Temperature CP198R134a Medium Temperature CP198R404a Low Temperature CP198
Easypack Sealed Condensing Units CP199R404a Medium Temp CP200R404a Low Temp CP200
Realpack Packaged Refrigeration Condensing Units CP201R404a Medium Temperature CP201R404a Low Temperature CP201
Realcold Milk Vat Air Cooled Condensing Units CP202On Farm Refrigeration CP202Water Heating Options CP202
Copeland Scroll Condensing Units CP203R404a Medium Temperature CP203R404a Low Temperature CP203
Realcold Custom Build Semi-Sealed Units CP204R404a Medium Temperature CP205R404a Low Temperature CP205
Realcold Semi-Sealed Compressor Receiver Packages CP206R404a Medium / Low Temp CP206
Realcold Semi-Sealed, Copeland Scroll Unit Accessories CP207Liquid Line Assembly - Medium & Low Temp Models CP207Oil Separator Assembly CP207Oil Return Line Sightglass CP207Suction Line Assembly CP207Suction Line Refillable Filter Assembly CP208Suction Line Filter Fitted Assembly CP208Pressure Controls CP208Capacity Controls CP208Miscellaneous CP208
Realcold Air Cooled Condensers CP209Vertical Discharge CP209Horizontal Discharge CP210Hanwest Water Cooled Marine Condenser CP210
Realcold Evaporator Units CP211HCT Series - Medium Temp - No Defrost CP212HCT Series - Low Temp - Full Electric Defrost CP212Rondo Series - Medium Temp - No Defrost CP212TM Dual Discharge - Medium Temp - Air Defrost CP212N Series Medium Temp - Air Defrost CP213N Series - Low Temp - Full Electric Defrost CP213S Series - Medium Temp - Air Defrost CP214S Series - Medium Temp - Partial Defrost CP214S Series - Low Temp - Full Electric Defrost CP214R Series - Medium Temp - Air Defrost CP215V Series - Medium Temp - Air Defrost CP215R Series - Low Temp - Electric Defrost CP215V Series - Low Temp - Electric Defrost CP215
Hc Evaporator Range CP216Realcold Medium Temperature Evaporators CP216Realcold Low Temperature Evaporators CP217
Ice Machines CP218
Chilled Water Packages CP222
Compressor And Condensing Unit Warranty CP223
CP196
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
L’Unite Hermetique is a brand name of Tecumseh Europe, recognised as a leader in commercial refrigeration compressor manufac-ture. For more than 50 years, Tecumseh has been developing and manufacturing compressors, condensing units and fan motors. Reliability, performance, silent operation, easy installation and ergonomics are the driving force behind the company, with an overall focus on differentiation and development of customer loyalty.
L’Unite has a proud tradition and a strong future, and the condensing unit range to suit a wide variety of applications.
L’Unite Sealed condensing units feature:
• ULapprovedreceivers
• FanGuard
• Pre-Wiredcompressorandfanmotor
• Suctionlineisolatingvalve
• Liquidlineisolatingvalves
• FH/TFHmodelsaresuppliedcompletewithDPcontrol/CCheater, oil level sight glass fitted CAJ4517, CAJ4519 complete with DP control
• 12monthmanufacturerswarranty
• ManufacturedbyTecumseh Europe
L’UNITE SEALED
CP197
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
DRAWINGS OF L’UNITE SEALED CONDENSING UNITS
FH Series CAJ Series
CAE Series AEZ Series
Drawings
CP198
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
L´UNITE SEALED CONDENSING UNITS
R404a Medium TemperatureRealcoldStock No.
Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST
-10 -5 0 7.5 10 L W H
220/240 Volt 50 Hz Single Phase
C9407^ AEZ4425ZHR ‘1/5 4.5 316 386 458 565 608 417 317 224 508.73
C9408^ AEZ4430ZHR ‘1/4 5.7 445 534 628 773 833 389 330 257 498.37
C9412^ AEZ4440ZHR ‘1/3 7.55 600 712 831 1012 1085 490 350 292 537.91
C9426^ CAE4450ZHR ‘3/7 9.4 738 881 1034 1274 1374 490 350 292 644.58
C9430^ CAE9460Z MHR ‘1/2 11.3 880 1035 1195 1435 1532 490 356 292 719.15
C9432^ CAE9470Z MHR ‘1/2 13.3 1123 1322 1532 1852 1984 490 430 338 771.36
C9442^ CAJ9480Z MHR ‘5/8 15.2 1317 1562 1825 2231 2397 480 430 338 994.03
C9444^ CAJ9510Z MHR ‘1 18.3 1599 1888 2196 2671 2876 486 430 338 1,067.87
C9446^ CAJ9513Z MHR ‘1 1/8 24.2 1858 2176 2488 2913 3068 486 430 338 1,148.91
C9448 CAJ4517Z HR ‘1 1/4 25.95 2354 2792 3225 3842 4079 620 510 450 1,472.56
C9450 CAJ4519Z HR ‘1 1/2 34.45 2924 3452 3999 4812 5136 620 510 450 1,553.67
C9470 FH4524ZHR ‘2 43.5 3180 3768 4400 5342 5722 620 510 450 1,784.48
C9473 FHS4531Z HR ‘2 1/2 56.65 4381 5169 5962 7111 7561 608 628 558 2,187.74
R134a Medium TemperatureRealcoldStock No.
Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST
-10 -5 0 7.5 10 L W H
220/240 Volt 50 Hz Single Phase
C9126^ AEZ4425Y HR ‘1/5 7.55 334 418 507 644 700 417 314 224 547.74
C9130^ AEZ4430Y HR ‘1/4 8.85 416 516 625 796 867 389 330 257 547.62
C9142^ CAE4440Y HR ‘1/3 12.05 546 667 797 997 1079 389 330 257 576.01
C9150^ CAE4448Y HR ‘3/8 14.15 657 810 971 1217 1318 490 350 292 695.41
C9152^ CAE4456Y HR ‘3/7 16 721 888 1069 1353 1470 490 350 292 689.23
C9156^ CAJ4461Y HR ‘1/2 18.3 767 933 1110 1380 1487 485 356 305 831.74
C9160^ CAJ4492Y HR ‘3/4 25.95 1254 1552 1878 2390 2600 486 430 338 1,010.76
C9162^ CAJ4511Y HR ‘1 32.7 1576 1917 2279 2826 3043 486 430 338 1,115.91
C9170 FH4518Y HR ‘1 1/2 53.2 2425 3026 3690 4760 5214 620 510 450 1,605.28
C9173 FH4525Y HR ‘2 74.25 2925 3629 4389 5581 6076 630 510 450 1,690.98
R404a Low TemperatureRealcoldStock No.
Model Nom. HP Disp. cm³ Capacity (w) Ambient 32 Dimensions (mm) System Price$ Excl. GST
-30 -25 -20 -15 -10 L W H
220/240 Volt 50 Hz Single Phase
C9406^ AEZ2415Z BR ‘3/8 8.1 267 337 407 484 567 417 314 224 429.68
C9418^ CAE2417Z BR ‘1/2 11.3 321 408 495 587 682 495 338 243 538.35
C9420^ CAE2420Z BR ‘1/2 12.54 394 499 605 716 832 389 330 257 623.19
C9422^ CAE2424Z BR ‘5/8 15 518 645 772 910 1057 510 356 292 622.20
C9436^ CAJ2432Z BR ‘3/4 18.3 594 729 864 1022 1195 485 342 299 713.19
C9438^ CAJ2446Z BR ‘1 26.18 937 970 1416 1690 1989 486 430 338 1,002.50
C9440^ CAJ2464Z BR ‘1 1/2 35.45 1172 1463 1755 2067 2382 486 430 338 1,119.98
C9462 FH2480Z BR ‘2 53.2 1641 2030 2519 2980 3417 620 510 450 1,533.89
• ^ Note that these units do not include a pressure switch.
• All ratings are based on an ambient of +30°C , 10K Superheat, 2K Sub-Cooling.
• Refer to warranty section of catalogue for warranty details.
CP199
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
EASYPACK SEALED CONDENSING UNITS
EasyPack - Realcold Condensing Units Feature:
• All units fitted with dual pressure controls
• Compressor / fan motor wired (Single Phase Units Only)
• Liquid line isolating valves
• Suction isolating valves
• FH & TFH models are complete with crankcase heaters, oil sight glasses
• Unit warranty as per page CP225
Custom Design & Build Service
Realcold offer a full range of custom designed units based upon the L’Unite Sealed and the Frascold Semi/Screw range of Compressors.
These units can be manufactured to suit your individual requirements encompassing all of the common refrigerants from R134a through to C02. Please contact your local Realcold branch for further information.
CP200
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
EASYPACK CONDENSING UNITS
R404a Medium TempRealcoldStock No.
Compressor H/P Capacity (w) Ambient 32 Suction (mm)
Liquid (mm)
Wgt (Kg)
Sound Power (dBA)
Dimensions (mm) System Price Excl. GST
-10 -5 0 5 10 L W H
220/240 Volt 50Hz Single Phase
C0757E CAJ 9513 Z 1 1/8 2108 2405 2807 3220 3635 15.9 9.5 47 76 550 650 465 1,450.00
C0758E CAJ 4517 Z 1 1/4 2272 2845 3168 3634 4100 15.9 9.5 60 77 600 600 560 1,525.00
C0759E CAJ 4519 Z 1 1/2 2526 3638 4241 4864 5499 15.9 9.5 60 79 600 600 560 1,795.00
C0762E FH 4524 Z 2 3586 4291 5023 5786 6587 15.9 9.5 73 79 600 600 560 2,532.00
C0764E FH 4531 Z 2 1/2 4855 5850 6764 7754 8767 22.2 9.5 76 79 600 600 560 2,839.00
R404a Medium TempRealcoldStock No.
Compressor H/P Capacity (w) Ambient 32 Suction (mm)
Liquid (mm)
Wgt (Kg)
Sound Power (dBA)
Dimensions (mm) System Price Excl. GST
-10 -5 0 5 10 L W H
400 Volt 50Hz Three Phase
C0964E TFH 4540 Z 3 5628 6740 7908 9149 10481 22.2 12.7 80 82 600 600 560 2,839.00
C0968E TAG 4553 Z 4 1/2 7332 8948 10685 12509 14387 22.2 12.7 118 84 1080 680 565 3,350.00
C0971E TAG 4561 Z 5 7567 9713 11323 13365 15382 28.6 12.7 118 84 1080 680 565 3,680.00
C0973E TAG 4573 Z 6 1/4 10023 12034 14168 16426 18808 28.6 12.7 135 84 1080 680 565 3,980.00
C0977E 2 x TAGP 4553 Z 9 13946 17104 20605 24207 27667 28.6 15.9 213 87 1420 730 870 5,500.00
C0980E 2 x TAGP 4561 Z 10 16904 20225 23683 27278 31010 28.6 15.9 218 87 1420 730 870 6,250.00
C0985E 2 x TAGP 4573 Z 12 22356 25974 30077 34665 39738 28.6 15.9 218 87 1420 730 870 6,875.00
R404a Low TempRealcoldStock No.
Compressor H/P Capacity (w) Ambient 32 Suction (mm)
Liquid (mm)
Wgt (Kg)
Sound Power (dBA)
Dimensions (mm) System Price Excl. GST
-30 -25 -20 -15 -10 L W H
220/240 Volt 50Hz Single Phase
C0787E CAJ 2464 Z 1 1/2 1184 1495 1840 2212 2608 15.9 9.5 40 76 550 650 395 1,484.00
C0789E FH 2480 Z 2 1800 2271 2746 3225 3709 15.9 9.5 73 79 600 600 560 2,165.00
R404a Low TempRealcoldStock No.
Compressor H/P Capacity (w) Ambient 32 Suction (mm)
Liquid (mm)
Wgt (Kg)
Sound Power (dBA)
Dimensions (mm) System Price Excl. GST
-30 -25 -20 -15 -10 L W H
400 Volt 50Hz Three Phase
C0793E TFH 2511 Z 3 2356 3030 3767 4566 5427 15.9 9.5 80 82 600 600 560 2,567.00
C0794E TAG 2516 Z 4 3268 4188 5188 6269 7430 22.2 9.5 107 81 1080 680 565 3,064.00
C0795E TAG 2522 Z 5 4202 5401 6674 8019 9438 22.2 9.5 107 81 1080 680 565 4,220.00
C0796E 2 x TFHP 2511 Z 6 4633 5921 7296 8619 10006 28.6 9.5 156 81 1080 800 570 6,750.00
CO797E 2 x TAGP 2516 Z 8 6508 8417 10540 12878 15430 22.2 15.9 210 82 1420 730 870 7,250.00
C0798E 2 x TAGP 2522 Z 10 7713 9850 12220 14822 17658 28.6 15.9 215 83 1420 730 870 8,750.00
Note: All of the EasyPack Units are available for operation on R134a. Please contact the Technical Department with your requirements.
CP201
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALPACK PACKAGED REFRIGERATION CONDENSING UNITS
RealPack Features:
• TecumsehL’UniteHermetiquecompressors
• DesignedforR404aandR507refrigerants
• Suitableforambienttemperaturesupto46°C-lowoperatingcost
• Condenserfancontrolforstableoperation
• Condensercoilprotection
• OilSeparatoronallmodels
• Liquiddrierandsightglassonallmodels
• SuctionAccumulatoronlowtemperaturemodels
• Easyaccesstoallserviceablecomponents
• Easyandcosteffectiveinstallation-fullywired&robustpowdercoatedenclosure
R404a Medium TemperatureRealcoldStock No.
Compressor Nom. HP
Capacity (w) Ambient 32 Suction connect.
Liquid connect.
Dimensions (mm) System Price$ Excl. Gst
-10 -5 0 5 10 L W H
240 Volt 50Hz Single Phase
C9513 CAJ4517Z 1 1/4 2269 2863 3559 4356 5256 5/8 3/8 1070 480 750 3,055.92
C9515 CAJ4519Z 1 1/2 2992 3783 4686 5702 6829 5/8 3/8 1070 480 750 3,402.72
C9520 FH4524Z 2 3516 4460 5546 6773 8143 5/8 3/8 1070 480 750 3,645.48
415 Volt 50Hz Three Phase
C9525 TFH4531Z 2 1/2 4566 5813 7225 8805 10551 5/8 3/8 1285 625 820 4,256.46
C9530 TFH4540Z 3 6155 7571 9235 11147 13307 5/8 3/8 1285 625 820 4,843.98
C9545 TAG4553Z 4 1/2 6764 8855 11372 14317 17690 7/8 1/2 1285 625 820 5,142.84
C9550 TAG4561Z 5 8163 10446 13234 16526 20326 7/8 1/2 1285 625 820 5,555.94
C9561 TAG4573Z 6 1/4 10633 13346 16638 20511 24966 7/8 1/2 1285 625 820 5,703.84
C9575 2xTAGP4546Z 7 1/2 11716 15690 20244 25380 31100 1 1/8 5/8 1660 790 1015 8,800.00
C9590 2xTAGP4561Z 10 16326 20892 26468 33052 40652 1 1/8 5/8 1660 790 1015 9,850.00
C9596 2xTAGP4573Z 12 1/2 21266 26692 33276 41022 49932 1 1/8 5/8 1660 790 1015 10,500.00
R404a Low TemperatureRealcoldStock No.
Compressor Nom. HP
Capacity (w) Ambient 32 Suction connect.
Liquid connect.
Dimensions (mm) System Price$ Excl. Gst
-30 -25 -20 -15 -10 L W H
220/240 Volt 50Hz Single Phase
C9522 FH2480Z 2 1741 2296 2852 3518 4209 5/8 3/8 1070 480 750 3,876.00
400 Volt 50Hz Three Phase
C9532 TFH2511Z 3 2503 3206 3910 4743 5617 5/8 3/8 1285 625 820 4,396.20
C9542 TAG2516Z 4 3406 4498 5590 6865 8212 7/8 1/2 1285 625 820 5,056.14
C9552 TAG2522Z 5 4455 5746 7037 8563 10179 7/8 1/2 1285 625 820 5,279.52
C9580 2xTAGP2516Z 8 6750 8874 10999 13503 16118 1 1/8 5/8 1660 790 1015 9,450.00
C9593 2xTAGP2522Z 10 9144 11693 14243 17657 21182 1 1/8 5/8 1660 790 1015 9,890.00
• Note that all capacities are rated at 30°C ambient, 10K superheat, 2K sub-cooling.
• For complete technical data, refer to Appendix TD227.
CP202
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD MILK VAT AIR COOLED CONDENSING UNITS
Realcold Milk Vat Units (RMV)
Next Generation for On-farm Refrigeration. Purpose built with the milk shed environment and servicing in mind.
Ease of service: Simple in its design. No unnecessary complicated electronics. Components available from a wide range of suppliers.
Proven reliability: Retains use of reciprocating technology in an innovative way. No compromising system efficiency.
Availability: Units held in stock.
Affordable: Competitively priced.
Superior Efficiency: Multiplexed compressors enable the most efficient use of energy.
Ease of adaptability: Adaptable to a wide range of applications, from a single platform:
• Saturation temperatures from +20°C to -35°C
• Condensing temperatures up to +55°C
• Capacities from 2 kW to 40 kW
On Farm RefrigerationRealcoldStock No.
Model Compressor Nom. HP Cooling Capacity kW
Dimensions (mm) Weight (Dry) Kg System Price$ Excl. Gst
L D H
380 - 415V 50Hz Three Phase
C6720 RMV 450 TAG 4553Z 4.5 11.4 1080 680 565 118 POA
C6721 RMV 600 TAG 4573Z 6.0 15.1 1080 680 565 135 POA
C6722 RMV 900 TAG 4553Z 9.0 22.0 1420 730 870 213 POA
C6723 RMV 1000 TAG 4561Z 10.0 25.1 1420 730 870 218 POA
C6724 RMV 1200 TAG 4573Z 12.0 31.9 1420 730 870 218 POA
C6725 RMV 1500 TAG 4561Z 15.0 36.3 1900 1120 870 300 POA
Water Heating OptionsRealcoldStock No. NormalDesuperheaters
RealcoldStock No.Full SizeDesuperheaters
Model Hot Water Heating Capacity kW* System Price$ Excl. GST
Normal / Full SizeDesuperheaters
OHC15-20 OMC60-20 RMV 450 5 POA
OHC15-20 OMC60-20 RMV 600 8.3 POA
OHC15-20 OMC60-30 RMV 900 11 POA
OHC15-20 OMC60-30 RMV 1000 12.4 POA
OHC15-30 OMC60-30 RMV 1200 15.2 POA
OHC15-30 OMC60-40 RMV 1500 18.2 POA
Features include:
• Single, Twin or Triple multiplexed compressors offering staged capacity control over a wide range of applications.
• 6 sizes, covering capacities from 11 to 36 kW.
• ASERCOM compressor certification, assuring independent verification of published performance capacity figures.
• Horizontial air flow. Performance rated at up to 55 degrees condensing temperature.
Specifications:
• Compressor: Each high efficiency hermetic type compressor is hermetically sealed, quiet running and supported on rubber mounts to minimise vibration.
• Cooling Capacity: Rated @ 2°C SST / 45°C SCT / 32°C Ambient on R404a refrigerant.
• Refrigeration Piping: The standard unit allows for a line length of up to 30m.
• Wiring: Electrical supply required (including voltage fluctuation limits). 3 phase 342-436 V a.c. 50 Hz with neutral and earth. A control panel located in the outdoor unit is fully wired, ready to accept the main power supply.
• Safety Features: HP / LP switch and an anti rapid cycle timer for compressor protection. The compressor also has internal overload protection. Circuit breaker control circuits.
CP203
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
COPELAND SCROLL CONDENSING UNITS
Custom Design & Build Service
Copeland Scroll Condensing Units, both sealed and semi, are designed and manufactured in New Zealand, using Copeland Compressors. All units can be manufactured to suit your individual requirements. Refer to the following accessory pages for options and pricing. (Note: Condensing units must be selected on rated capacity NOT nominal HP rating).
Copeland Scroll Condensing Units include:
• UnitsfittedwithCopelandZBrefrigerationratedscrollcompressors (not ZR air con rated models)
• Allunitsfittedwithdualpressurecontrols
• Receiveroutletvalve
• CompressorRotolockvalves
• Oilandsightglass
• UnitwarrantyasperpageCP223
R404a Medium TemperatureRealcoldStock No.
Model Compressor Nom. HP M³ / HR Disp.
R404a Capacity in Watts @ -5°C SST
Condenser Dimensions (mm) System Price$ Excl. Gst
L D H
380/415 Volt 50Hz Three Phase
CUS 0223 CMTZ 400 ZB30KQE-TFD 4.0 11.8 8530 SCS2150 1052 914 519 POA
CUS 0225 CMTZ 500 ZB38KQE-TFD 5.0 14.5 10430 SCT2170 1269 914 723 POA
CUS 0228 CMTZ 600 ZB45KQE-TFD 6.0 17.2 12460 SCT2215 1269 914 723 POA
CUS 0230 CMTZ 750 ZB58KQE-TFD 7.5 20.9 13850 SCT2215 1269 914 723 POA
CUS 0233 CMTZ 1000 ZB76KQE-TFD 10.0 28.9 19860 SCR2275 1484 1034 775 POA
CUS 0235 CMTZ 1300 ZB92KCE-TWD 13.0 35.6 25290 SCR2385 1484 1034 928 POA
CUS 0238 CMTZ 1500 ZB11MCE-TWD 15.0 42.1 30960 SCR2475 1484 1034 1028 POA
R404a Low TemperatureRealcoldStock No.
Model Compressor Nom. HP M³ / HR Disp.
R404a Capacity in Watts @ -25°C SST
Condenser Dimensions (mm) System Price$ Excl. Gst
L D H
380/415 Volt 50Hz Three Phase
CUS 0263 CLTZ 600 ZF18K4E-TFD 6.0 17.2 5850 SCS2150 1052 914 723 POA
CUS 0265 CLTZ 750 ZF24K4E-TFD 7.5 20.9 7110 SCT2170 1269 914 723 POA
CUS 0268 CLTZ 1000 ZF33K4E-TFD 10.0 28.9 9670 SCT2215 1269 914 723 POA
CUS 0270 CLTZ 1300 ZF40K4E-TFD 13.0 35.6 12090 SCR2275 1484 1034 776 POA
CUS 0273 CLTZ 1500 ZF48K4E-TFD 15.0 42.1 14950 SCR2385 1484 1034 928 POA
• Note that all capacities are rated at 30°C ambient, 10K useful superheat, 2K sub-cooling.
• For complete technical data, refer to appendix TD227.
• For accessories, refer to CP215 & CP216.
CP204
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD CUSTOM BUILD SEMI-SEALED UNITS
Custom Design & Build Service
Frascold semi-sealed condensing units, are designed and manufactured in New Zealand, using Frascold Compressors. All units can be manufactured to suit your individual requirements. Refer to the following accessory pages for options and pricing. (Note Condensing units must be selected on rated capacity NOT nominal HP rating).
Frascold Condensing Units include:
• UnitsfittedwithFrascoldrefrigerationratedsemi-sealedcompressors (not ZR air con rated models)
• Allunitsfittedwithdualpressurecontrols
• Receiveroutletvalve
• CompressorRotolockvalves
• Oilandsightglass
• UnitwarrantyasperpageCP225
Low Clearance High Capacity Piston Valve Plate Assembly features on all Frascold compressors. Specially contoured pistons and low cylinder clearance = increased capacity.
EC 93/68/CEE
Underwriters Laboratory
R404a R407A R407B R407c R134a R507
CP205
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD CUSTOM BUILD SEMI-SEALED UNITS
R404a Medium TemperatureRealcoldStock No.
Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ -5°C SST
Condenser Dimensions (mm) System Price$ Excl. Gst
L W H
220/240 Volt 50Hz Single Phase
C5317M SAR16A 1.0 5.47 3270 SCN148 570 415 405 POA
C5323M SAR157A 1.5 6.91 4100 SCS158 974 649 519 POA
380/415 Volt 50Hz Three Phase
C5329M SAR157A 1.5 6.91 4100 SCS158 974 649 519 POA
C5333M SAR210B 2.0 9.84 6090 SCT189 974 665 620 POA
C5346M SAR313D 3.0 13.84 8150 SCT1120 974 1052 620 POA
C5349M SAR418D 4.0 17.83 9990 SCT2170 914 1269 723 POA
C5359M SAR524F 5.0 23.60 14790 SCT2215 914 1269 723 POA
C5362M SAR728Q 7.5 27.31 17110 SCT2215 914 1269 723 POA
C5366M SAR733S 7.5 32.80 20690 SCR2275 1034 1469 775 POA
C5374M SAR1039S 10.0 38.25 23650 SCR2385 1034 1469 928 POA
C5379M SAR1551S 15.0 50.43 30910 SCR2475 1034 1469 1028 POA
*C5382M SAR2059V 20.0 58.48 36710 SCV2720 1096 2154 965 POA
*C5386M SAR2571V 25.0 70.97 44540 SCV2720 1096 2154 965 POA
*C5387M SAR3084V 30.0 83.81 53000 SCV2850 1096 2154 1065 POA
*C5390M SAR35106Z 35.0 106.16 63410 SCV2850 1096 2154 1065 POA
R404a Low TemperatureRealcoldStock No.
Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ -25°C SST
Condenser Dimensions (mm) System Price$ Excl. Gst
L W H
220/240 Volt 50Hz Single Phase
C5319L SAR159B 1.5 8.96 2320 SCS158 974 649 519 POA
380/415 Volt 50Hz Three Phase
C5321L SAR159B 1.5 8.96 2320 SCS158 974 649 519 POA
C5337L SAR213D 2.0 13.84 3550 SCT189 974 649 620 POA
C5341L SAR318D 3.0 17.83 4850 SCT1120 974 649 620 POA
C5351L SAR424F 4.0 23.60 6580 SCS2150 914 1052 723 POA
C5362L SAR528Q 5.0 27.31 7430 SCS2150 914 1052 519 POA
C5366L SAR733S 7.5 32.80 8800 SCT2170 914 1269 723 POA
C5368L SAR739S 7.5 38.25 10820 SCT2215 914 1269 723 POA
C5377L SAR1051S 10.0 50.43 14080 SCT2255 914 1269 723 POA
*C5380L SAR1559V 15.0 58.48 15700 SCR2275 1034 1484 776 POA
*C5381L SAR1571V 15.0 70.77 19380 SCR2385 1034 1484 928 POA
*C5384L SAR2084V 20.0 83.81 22500 SCR2475 1034 1484 1028 POA
*C5389L SAR25106Z 25.0 106.16 29350 SCV2720 1096 2154 965 POA
*C5391L SAR30126Z 30.0 125.72 35020 SCV2850 1096 2154 1065 POA
*C5393L SAR40154Z 40.0 154.38 41660 SCV2850 1096 2154 1065 POA* Units fitted with Oil Pressure Safety Control.
• Note that all capacities are rated at 30°C ambient, 10K useful superheat, 2K sub-cooling
• For complete technical data, refer to appendix TD228.
• For accessories, refer to CP215 & CP216.
CP206
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD SEMI-SEALED COMPRESSOR RECEIVER PACKAGES
R404a Medium / Low TempRealcoldStock No.
Model Nom. HP M³ / HR Disp. R404a Capacity in Watts @ +40°C SCT (W)
R404a Pump Down Capacity (Kg)
Application System Price$ Excl. Gst
-5°C SST -25°C SST R404a R22 R134a
C5429 CR728Q 7.5 29.36 18390 7510 33 HML HML HM POA
C5433 CR733S 7.5 32.80 21870 8770 33 HML HML HM POA
C5434 CR739S 7.5 38.25 - 10850 33 L L HM POA
C5439 CR1039S 10 38.25 25900 10690 54 M HML HM POA
C5442 CR1051S 10 50.43 - 14120 54 L L HM POA
C5444 CR1551S 15 50.43 33400 13480 54 M M HM POA
*C5445 CR1559V 15 58.84 - 16160 54 ML ML HM POA
*C5450 CR1571V 15 70.77 - 19440 54 L ML HM POA
*C5455 CR2059V 20 58.84 39220 15790 80 HML HML HM POA
*C5462 CR2084V 20 83.81 - 23410 80 L ML HM POA
*C5464 CR2571V 25 70.77 46620 18780 80 HML HM HM POA
*C5466 CR3084V 30 83.81 55710 22770 80 HML HM HM POA
*C5467 CR25106Z 25 106.16 - 28960 80 L ML HM POA
*C5468 CR30126Z 30 125.72 - 34760 80 L ML HM POA
*C5470 CR35106Z 35 106.16 70460 28350 105 HML HM HM POA
*C5475 CR40126Z 40 125.72 84730 34190 105 HML HM HM POA
*C5477 CR40154Z 40 154.38 - 43400 80 ML ML HM POA
*C5480 CR50154Z 50 154.38 104410 41970 105 ML HM HM POA
*C5482 CR50187W 50 186.10 - 53080 105 L L M POA
*C5485 CR60187W 60 186.10 127640 51100 105 ML ML HM POA
*C5488 CR60206W 60 205.80 - 58650 105 L L HM POA
*C5491 CR70206W 70 205.80 140220 56640 105 ML HM HM POA* Compressor fitted with Oil Pressure Safety Control.
Realcold Semi-Sealed Compressor Receiver Packages
• CompressorReceiverPackagesaresuppliedcompletewithtwoRotolockvalves,aPressureReliefValveandaDualPressureControl. Oil Protection Controls fitted to V/Z & W only.
• ReceiversaredesignedandconstructedinaccordancewiththerequirementsofBS5500(1988).
• Refrigeration capacities rated @ 40°C condensing temperature, 2°Csub-cooled liquid, 10°C useful superheat.
• RefertopageCP207foraccessories.
• Seewarrantysectionofcatalogueforwarrantydetails.
• Note: Custom Built Parallel Racks are available - please talk with our Technical Applications Engineers who will be happy to discuss options with you.
CP207
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD SEMI-SEALED, COPELAND SCROLL UNIT ACCESSORIES
Liquid Line Assembly - Medium & Low Temp ModelsIncludes Drier, Liquid Moisture Indicator, Solenoid Valve, Pipework Fitted
RealcoldStock No.
Line Size Drier Size Refillable Shell Suits Models System Price$ Excl. Gst
C5901 1/4" Assy DCY052 - 0.75 HP 289.68
C5903 3/8" Assy DCY083 - 1.5 HP to 2 HP 315.18
C5904 1/2" Assy DCY084 - 2 HP to 5 HP 325.38
C5906 1/2" Assy DCY414 - 5 HP to 7.5 HP 365.16
C5908 5/8" Assy DCY415 - 7.5 HP Medium Temp Only
416.16
C5909 5/8" Assy BCY485S One 10 HP to 20 HP Medium Temp Only
613.02
C5911 7/8" Assy BCY9675 Two 20 HP to 40 HP 678.30
C5912 1 1/8" Assy BCY9695 Two 40 HP to 70 HP Low Temp Only
742.56
C5913 1 3/8" Assy C-14411G Three 60 HP to 70 HP Medium Temp Only
1,050.60
Note: Low Temperature -25°C Evap. Medium Temperature -5°C Evap.
Oil Separator AssemblyIncludes Oil Separator, Vibration Eliminator, Pipework Fitted
RealcoldStock No.
Line Size Suits HP System Price$ Excl. Gst
C5931 1/2" 1 HP to 1 1/2 HP 329.46
C5932 5/8" 2 HP to 3 HP 335.58
C5933 7/8" 4 HP to 5 HP 422.28
C5934 1 1/8" 7 1/2 HP to 20 HP 482.46
C5935 1 3/8" 25 HP to 35 HP 563.04
C5936 1 5/8" 40 HP to 50 HP 728.28
C5937 2 1/8" 50 HP to 60 HP 918.00
C5938 2 5/8" 60 HP to 70 HP 1,868.64
Oil Return Line SightglassRealcoldStock No.
Line Size Suits HP System Price$ Excl. Gst
C5995 3/8” sweat. All models 3/4 HP to 10 HP 69.36
Suction Line AssemblySuits Models Up To SAR1051S. Includes Accumulator, Vibration Eliminator and Pipework Fitted
RealcoldStock No.
Line Size Suits Models System Price$ Excl. Gst
C5945 5/8" Assy 1.5 HP 235.62
C5946 3/4" Assy 2 HP Medium Temp Only 239.70
C5947 7/8" Assy 2 HP Low Temp Only 278.46
C5948 1 1/8" Assy 3 HP to 6 HP 302.94
C5949 1 3/8" Assy 7.5 HP to 15 HP 425.34
CP208
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD SEMI-SEALED, COPELAND SCROLL UNIT ACCESSORIES
Suction Line Refillable Filter AssemblySuits models SA728F up to CR70206W. Includes Refillable Filter, Accumulator, Vibration Eliminator and Pipework Fitted
RealcoldStock No.
Line Size Suits Models System Price$ Excl. Gst
C5956 1 3/8" Assy (c/w one core drier) 6 HP to 10 HP 721.14
C5957 1 5/8" Assy (c/w one core drier) 15 HP to 20 HP 817.02
C5958 2 1/8" Assy (c/w one core drier) 25 HP to 35 HP 1,504.50
C5959 2 5/8" Assy (c/w two core drier) 40 HP to 50 HP 2,642.82
C5961 3 1/8" Assy (c/w two core drier) 50 HP to 70 HP 2,771.34
Suction Line Filter Fitted AssemblyIncludes Filter and Pipework Fitted
RealcoldStock No.
Line Size Suits Models System Price$ Excl. Gst
C5966 5/8" Assy 1.5 HP 102.46
C5968 7/8" Assy 2 HP 105.06
C5969 1 1/8" Assy 3 HP to 5 HP 110.16
C5970 1 3/8" Assy 7.5 HP to 10 HP 114.24
Pressure ControlsRealcoldStock No.
Description System Price$ Excl. Gst
C5987 LP Pump Down Control - Fitted 130.56
C5988 HP Condenser Fan Control - Fitted 131.58
C5989 HP/LP Control Fitted 187.68
Capacity ControlsRealcoldStock No.
Description System Price$ Excl. Gst
C5221 To suit “T” & “S” Series (Mk II) 1 cylinder head c/w solenoid 50% control 402.90
C5225 To suit “Z” & “V” & “W” Series 1 head only.
1 head for “V”=50% control.
1 head for “Z” = 33% control
2 heads for “Z”=33% & 66% control (Z:33%+66% = 2 x C5225)
2 heads for “W”=50% & 75% control (W:50%+75% = 2 x C5225
430.44
MiscellaneousRealcoldStock No.
Description System Price$ Excl. Gst
R0316 Rubber Mounts 40 x 40 mm, 2 - 3HP 35.75
R0552 Crankcase Heater F, S, T Series, 70 Watt, Fitted 160.14
R0553 Crankcase Heater A, B, D Series, 50 Watt, Fitted 160.14
R0555 Crankcase Heater (to suit V, W, Z Series) MK 2, 150 Watt Plain Shank, Fitted 238.68
C5805 Head Cooling Fan (to suit A, B, D, F Series), Fitted 514.08
C5808 Head Cooling Fan (to suit S, T, V, Z Series), Fitted 532.44
R0824 Delta-P Oil Differential Pressure Switch (to suit V, Z and W Series) 536.52
CP209
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD AIR COOLED CONDENSERS
Realcold Air Cooled Condensers Feature:
Manufactured by Steelfort, well known for its quality and innovation, these Air Cooled Condensers are the brand of
choice for a wide range of applications. Features include:
Casing: The casing is made from the highest quality aluminium construction, utilising rust free stainless steel fasteners throughout.
Heat Exchange Element (coil): Die formed plate type aluminium fins mechanically bonded to high efficiency inner grooved (rifled) copper tube.
Optional Epoxy Coated Aluminium Fins: For added protection in salt laden or polluted atmospheres.
Fans: Standard 630 diameter basket grill. Optional Ziehl or EC fans on request.
Custom built: Custom built units outside the standard range available on request.
Vertical DischargeRealcoldStock No.
Model Capacity kW @ 15KTD
Air Flow No.Fans Total Amps Dimensions (mm) System Price$ Excl. Gst
L D H
C5660 SCV 2100 100 6.6 2 3.6/ph. 2064 1243 1210 6,962.52
C5661 SCV 2115 115 6.9 2 3.6/ph. 2257 1243 1210 8,658.78
C5662 SCV 3145 144 10.4 3 5.4/ph. 3064 1243 1210 9,284.04
C5663 SCV 3160 162 9.9 3 5.4/ph. 3064 1243 1210 10,887.48
C5664 SCV 4200 196 12.8 4 7.2/ph. 3664 1243 1210 12,582.72
C5665 SCV 5230 230 17.5 5 9.0/ph. 4564 1243 1210 13,360.98
Dual Series
C5670 SCV 4200-2 200 13.2 4 7.2/ph. 2064 1243 1210 13,803.66
C5671 SCV 6280 288 20.8 6 7.2/ph. 3064 1243 1210 18,185.58
C5672 SCV 6320 324 19.8 6 10.8/ph. 3064 1243 1210 21,772.92
C5673 SCV 8390 392 25.6 8 14.4/ph. 3664 1243 1210 24,857.40
C5674 SCV 10460 460 35.0 10 18.0/ph. 4564 1243 1210 26,033.46
Note: For complete technical data, refer to Appendix TD235 - TD238.
Condensers - Ammonia
• Realcold is able to offer a range of Ammonia Air Cooled Condensers.
• Please contact the Realcold Technical Team if you would like to discuss this option in more detail and they will offer advice and solutions for you.
CP210
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD AIR COOLED CONDENSERS
Horizontal DischargeRealcoldStock No.
Model R404a Capacity in Watts @ 15°KTD
FansNo. / DiaNo. / mm
Dimensions (mm) System Price$ Excl. Gst
L D H
Single Phase
C8013 SCT 168 6659 1 x 400 630 205 530 684.42
C8015 SCT 189 8717 1 x 400 630 205 530 770.10
C8017 SCT 1120 11951 1 x 400 630 205 530 951.66
C8019 SCS 2120 11657 2 x 350 980 205 430 1,025.10
C8021 SCS 2150 14406 2 x 350 980 205 430 1,133.22
C8023 SCT 2170 16758 2 x 400 1200 205 635 1,207.68
C8025 SCT 2215 20977 2 x 400 1200 205 635 1,387.20
C8027 SCT 2255 25093 2 x 400 1200 205 635 1,569.78
C8029 SCR 2275 27500 2 x 500 1400 285 635 2,517.36
C8031 SCR 2385 38500 2 x 500 1400 285 840 3,000.84
C8033 SCR 2475 47250 2 x 500 1400 255 940 3,478.20
Three Phase
C8041 SCV 2720 72030 2 x 630 2050 285 840 4,663.44
C8043 SCV 2850 84481 2 x 630 2050 285 940 5,632.44
• All fans up to 500 mm 230V 1PH and 630 mm 400V 3PH.
• All Condensers fitted with fan motors and guards. Gussetts to be ordered extra.
• For complete technical data, refer to Appendix TD235 - TD238.
Hanwest Water Cooled Marine CondenserHanwest incorporates the latest in refrigerant heat exchanger technology. Compact, with high level of heat exchanger efficiency using cupro nickel tube. The best marine water cooled condensers for refrigeration or air conditioning installations. Ratings Based on Water Entering Temperature 30°C and 42°C Condensing.
RealcoldStock No.
Model Water Flow Rate Watts @ 10 KTD System Price$ Excl. Gst
F2002 CN2 0.16 L/sec 4836 775.20
F2003* CN3 0.20 L/sec 7000 831.30
F2004* CN4 0.17 L/sec 8250 955.74
F2005* CN5 0.37 L/sec 15800 1,091.40
F2006* CN6 0.62 L/sec 21100 1,227.06
F2010 Parallel Manifold 1" BSPT for CN2 36.26* These models are available on an indent basis only.
CP211
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD EVAPORATOR UNITS
Realcold Evaporator Coils Units Feature:
• Compactsizetocoolingcapacityratio.
• Excellentsurfaceareatocoolingcapacityratio.
• Hingeddrainpanwith“thumbscrews”foreasyaccesstodefrostelementsandcondensatepan.
• Hingedsidecoverswith“thumbscrews”foreasyaccesstoTEV,heatersafetyKlixon.
• Motorsanddefrostelementsareallpre-wiredtoterminalconnectionsintheelectricalbox.
• 1/4”accessportonallcoilsisastandardfeatureforcheckingin-coilpressuresandsettingupsuperheats.
• Flat4mmslottedmountingbrackets forveryquickeasy installation.Topof evaporator coil only 4 mm from ceiling panel easy to seal for hygiene purposes.
• Standard4.2mm fin spacingonmedium temperatureand low tem-perature models, easily inter-changed from low to medium temperature applications. Alternative fin spacing available on request.
• Lightweightconstruction,eventhelargecapacitycoilsareeasytolift,rangefrom 17-75 Kg on the N Series range, 92-98 Kg on the S Series range, 132-242 Kg on the R Series range and 242-510 Kg on the V Series range.
Rondo Two Fan HCT
Rondo Single Fan
HDT
CP212
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD EVAPORATOR UNITS
HCT Series - Medium Temp - No DefrostRealcoldStock No.
Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
W4600 HCT-251-2R 418 410 425 450 175 9.5 9.5 12.7 5.5 0.6 357.00
W4603 HCT-252-2R 990 970 750 450 175 9.5 9.5 12.7 11 1.0 554.88
W4605 HCT-252-3R 1235 1210 750 450 175 9.5 9.5 12.7 16 1.3 598.74
W4607 HCT-253-3R 1857 1820 750 450 175 9.5 12.5 20 20 1.9 823.14
W4609 HCT-254-3R 2480 2430 1400 450 175 9.5 12.5 20 30 2.0 1,066.92
HCT Series - Low Temp - Full Electric DefrostRealcoldStock No.
Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -24SST / 6KTD R404a
W4604 HCT-252-2RE - 830 750 450 175 9.5 9.5 20 11 1 722.16
W4606 HCT-252-3RE - 1016 750 450 175 9.5 12.5 20 16 1.3 766.02
W4608 HCT-253-3RE - 1528 1075 450 175 9.5 12.5 20 16 1.9 1,060.80
W4610 HCT-254-3RE - 2041 1400 450 175 9.5 12.5 20 16 2.3 1,378.02
Rondo Series - Medium Temp - No DefrostRealcoldStock No.
Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
W4000 Rondo 240 837 820 450 440 115 9.5 9.5 12.5 5.1 1.2 533.46
W4002 Rondo 340 1133 1110 450 440 140 9.5 9.5 12.5 6.2 1.2 564.06
W4008 Rondo 440 1476 1446 450 440 165 9.5 9.5 12.5 9 1.5 593.64
W4009 Rondo 500 1926 1887 760 430 170 9.5 9.5 12.5 11 2.0 657.90
W4010 Rondo 700 2372 2325 760 430 220 9.5 9.5 12.5 13 4.0 912.90
W4012 Rondo 900 3020 2960 1060 530 240 9.5 9.5 12.5 27 7.0 1,237.26
TM Dual Discharge - Medium Temp - Air DefrostRealcoldStock No.
Model Capacity @ 6 KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
W5500 TM140 4165 4082 1224 845 355 12.7 22.3 20 38 2.0 1,440.24
W5502 TM270 7143 7000 1705 850 360 12.7 22.3 20 59 3.0 2,283.78
W5504 TM3100 10204 10000 2205 850 360 12.7 28.1 20 85 4.2 3,178.32
W5508 TM4140 14286 14000 2705 850 360 12.7 28.1 20 121 6.0 4,114.68
Note: For complete technical data, refer to Appendix TD239 - TD243.
CP213
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD EVAPORATOR UNITS - N SERIES
N Series Medium Temp - Air DefrostRealcoldStock No.
Model Intern / Extern
Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -4 SST / 6 KTD
W5000 NM114 Intern 1400 1372 770 400 395 12.7 15.9 20 17 0.19 622.20
W5002 NM117 Intern 1690 1656 770 400 395 12.7 15.9 20 18 0.25 676.26
W5004 NM121 Intern 2090 2048 770 400 395 12.7 15.9 20 19 0.32 778.26
W5006 NM124 Intern 2370 2323 975 400 395 12.7 15.9 20 21 0.33 826.20
W5008 NM127 Intern 2710 2656 975 400 395 12.7 15.9 20 23 0.41 889.44
W5010 NM232 Intern 3200 3136 1270 400 395 12.7 15.9 20 25 0.34 1,026.12
W5012 NM240 Extern 3950 3871 1270 400 395 12.7 15.9 20 27 0.46 1,096.50
W5014 NM245 Extern 4520 4430 1270 400 395 12.7 22.3 20 29 0.58 1.181.16
W5016 NM254 Extern 5450 5341 1770 400 395 12.7 22.3 20 44 0.67 1,402.50
W5018 NM464 Extern 6400 6272 2270 400 395 12.7 22.3 20 50 0.66 1,622.82
W5020 NM374 Extern 7400 7252 1770 400 395 12.7 22.3 20 47 0.84 1,659.54
W5022 NM479 Extern 7895 7737 2270 400 395 15.9 28.1 20 58 0.88 1,801.32
N Series - Low Temp - Full Electric DefrostRealcoldStock No.
Model Intern / Extern
Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -24 SST / 6KTD
W5050 NL112 Intern - 1210 770 400 395 12.7 15.9 20 17 0.53 836.40
W5052 NL115 Intern - 1455 770 400 395 12.7 15.9 20 18 0.70 900.66
W5054 NL118 Intern - 1800 770 400 395 12.7 15.9 20 19 0.88 1,006.74
W5056 NL120 Intern - 2040 975 400 395 12.7 15.9 20 21 0.93 1,084.26
W5058 NL123 Intern - 2330 975 400 395 12.7 15.9 20 23 1.15 1,147.50
W5060 NL228 Intern - 2760 1270 400 395 12.7 15.9 20 29 0.95 1,328.04
W5062 NL234 Extern - 3400 1270 400 395 12.7 15.9 20 31 1.28 1,405.56
W5064 NL239 Extern - 3890 1270 400 395 12.7 22.3 20 33 1.60 1,492.26
W5066 NL347 Extern - 4695 1770 400 395 12.7 22.3 20 44 1.85 1,793.16
W5068 NL455 Extern - 5520 2270 400 395 12.7 22.3 20 50 1.83 2,134.86
W5070 NL364 Extern - 6375 1770 400 395 12.7 22.3 20 47 2.50 2,080.80
W5072 NL468 Extern - 6800 2270 400 395 15.9 28.1 20 58 3.00 2,332.74
Note: For complete technical data, refer to Appendix TD239 - TD243.
CP214
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD EVAPORATOR UNITS - S SERIES
S Series - Medium Temp - Air DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity At -4 SST / 6K TD
W5024 SM271 7102 6960 1483 482 510 12.7 22.3 20 48 2.97 1,643.22
W5026 SM386 8599 8427 2233 482 510 15.9 29 20 71 3.57 2,138.94
W5028 SM3105 10653 10440 2233 482 510 15.9 35 20 75 4.2 2,388.84
W5030 SM3125 12434 12185 2233 482 510 15.9 35 20 79 5.25 2,724.42
W5032 SM4140 14204 13920 2731 482 510 15.9 35 20 92 5.79 2,979.42
W5034 SM4165 16574 16243 2731 482 510 15.9 35 20 98 6.93 3,343.56
W5036 SM5210 21179 20340 3223 482 510 15.9 35 40 121 9.18 3,520.02
S Series - Medium Temp - Partial DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -4 SST / 6KTD
W5200 SM271P 7102 6960 1483 482 510 12.7 22.3 20 48 3.0 1,815.60
W5202 SM386P 8599 8427 2233 482 510 15.9 29 20 71 3.6 2,382.72
W5204 SM3105P 10653 10440 2233 482 510 15.9 35 20 75 4.2 2,632.62
W5206 SM3125P 12434 12185 2233 482 510 15.9 35 20 79 5.3 2,968.20
W5208 SM4140P 14204 13920 2731 482 510 15.9 35 40 92 5.8 3,305.82
W5210 SM4165P 16574 16243 2731 482 510 15.9 35 40 98 6.9 3,669.96
W5212 SM 5210P 18200 17836 3223 482 510 15.9 35 40 121 9.2 4,178.94
S Series - Low Temp - Full Electric DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -24 SST / 6KTD
W5074 SL261 6119.39 - 1483 482 510 12.7 22.3 20 48 2.48 2,015.52
W5076 SL374 7409.18 - 2233 482 510 15.9 29 20 71 2.98 2,650.98
W5078 SL392 9178.57 - 2233 482 510 15.9 35 20 75 3.50 2,900.88
W5080 SL3110 10713.27 - 2233 482 510 15.9 35 20 79 4.38 3,237.48
W5082 SL4120 12238.78 - 2723 482 510 15.9 35 40 92 4.83 3,668.94
W5084 SL4145 14281.63 - 2723 482 510 15.9 35 40 98 5.78 4,035.12
W5086 SL5180 17836.00 - 3290 440 535 15.9 35 40 121 9.20 4,264.62
Note: For complete technical data, refer to Appendix TD239 - TD243.
CP215
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
REALCOLD EVAPORATOR UNITS - R & V SERIES
R Series - Medium Temp - Air DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -4 SST / 6KTD
W5230 RM2140 14000 13333 2210 670 805 16 29 40 132 6.10 4,622.64
W5232 RM3185 18400 17524 2240 685 1075 16 35 40 173 7.40 5,582.46
W5234 RM3210 20600 19619 2740 685 1075 16 35 40 196 8.80 6,176.10
W5236 RM3230 23100 22000 2740 685 1075 16 35 40 198 9.90 7,183.86
W5238 RM3250 25200 24000 2740 685 1075 16 35 40 242 11.00 6,879.90
W5240 RM4280 28100 26762 2740 685 1075 16 35 40 242 11.00 8,046.78
V Series - Medium Temp - Air DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -4 SST / 6KTD
W5242 VM2310 31000 29524 2240 775 1305 16 35 40 280 14.5 8,334.42
W5244 VM2340 34400 32762 2240 775 1305 16 41 40 340 15.0 9,309.54
W5246 VM3400 40000 38095 3240 775 1305 16 41 40 420 17.0 9,582.90
W5248 VM3450 45100 42952 3240 775 1305 16 X 2 35 X 2 40 420 19.0 10,525.38
W5250 VM3480 48300 46000 3600 775 1305 16 X 2 35 X 2 40 430 19.0 11,197.56
W5252 VM4520 52000 49524 3600 775 1305 16 X 2 35 X 2 40 430 22.0 11,502.54
W5254 VM4560 56000 53333 3890 775 1305 16 X 2 35 X 2 40 510 28.0 12,028.86
V Series - Low Temp - Electric DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -24 SST / 6KTD
W5270 VL2280 28000 - 2240 775 1305 16 35 40 242 14.5 9,453.36
W5272 VL2300 30000 - 2740 775 1305 16 41 40 290 15.0 10,493.76
W5274 VL3350 35000 - 3240 775 1305 16 41 40 345 17.0 10,829.34
W5276 VL3400 40000 - 3240 775 1305 16 X 2 35 X 2 40 345 19.0 11,773.86
W5278 VL4450 45000 - 3600 775 1305 16 X 2 35 X 2 40 430 20.0 12,909.12
W5280 VL4500 50000 - 3890 775 1305 16 X 2 35 X 2 40 430 22.0 13,548.66
Note: Optional 2 speed Ziehl plate axial or EC fans available for R and V evaps series on request. For complete technical data, refer to Appendix TD239 - TD243.
R Series - Low Temp - Electric DefrostRealcoldStock No.
Model Capacity @ 6KTD Dimensions (mm) Connections Drain (BSP)
Weight (Kg)
Charge R404a (Kg)
System Price$ Excl. GST
134a 404a L W H Inlet Outlet
Capacity at -24 SST / 6KTD
W5260 RL3160 16200 - 2740 670 805 16 35 40 173 7.4 6,664.68
W5262 RL3185 18500 - 3240 670 805 16 35 40 196 8.8 7,263.42
W5264 RL3200 19700 - 2740 685 1075 16 35 40 198 9.9 8,142.66
W5266 RL4220 21700 - 3240 685 1075 16 35 40 198 11.0 7,870.32
W5268 RL4250 24700 - 3240 685 1075 16 35 40 242 12.0 9,038.22
CP216
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
HC EVAPORATOR RANGE
Realcold Medium Temperature EvaporatorsRealcoldStock No.
Model Capacity @ 6KTD Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections System Price$ Excl. GST
R404a R134a L W H Liquid Suction
Low Silotte Ceiling Mount
W4600 HCT - 251 - 2R 410 390 1 x 250 0.14 425 450 177 5.2 3/8 3/8 365.93W4603 HCT - 252 - 2R 970 923 2 x 250 0.28 750 450 177 7.8 1/2 1/2 568.75W4605 HCT - 252 - 3R 1210 1151 2 x 250 0.24 750 450 177 8.4 1/2 1/2 613.71W4607 HCT - 253 - 3R 1820 1732 3 x 250 0.36 1075 450 177 11.7 1/2 1/2 843.72W4609 HCT - 254 - 3R 2430 2312 4 x 250 0.49 1400 450 177 15 1/2 1/2 1,093.59
RondoW4001 Ron - 140-A 630 599 1 x 250 0.21 455 440 120 4 3/8 3/8 412.00W4000 Ron - 240-A 800 761 1 x 250 0.19 455 440 120 4.5 3/8 3/8 546.80W4002 Ron - 340-A 950 904 1 x 250 0.21 455 440 145 5 1/2 1/2 578.16W4008 Ron - 440-A 1080 1028 1 x 250 0.22 455 440 170 5.5 1/2 1/2 608.48W4009 Ron - 500-A 1660 1579 2 x 250 0.37 760 430 175 8.3 1/2 1/2 674.35W4010 Ron - 700-A 2060 1960 2 x 250 0.43 760 430 230 9.4 1/2 5/8 935.72W4012 Ron - 900-A 3380 3216 2 x 300 0.92 1060 530 230 14 1/2 5/8 1,268.19W4013 Ron - 1100-A 4040 3844 2 x 300 1.05 1060 530 265 15.4 1/2 3/4 1,300.00W4014 Ron - 1300-A 4640 4414 2 x 300 0.94 1060 530 265 17.4 1/2 3/4 1,370.00
Dual DischargeW5500 HDD - 351 - 4R 4070 3872 1 x 350 0.75 954 1200 350 26 1/2 7/8 3,440.00W5502 HDD - 352 - 3R 8160 7763 2 x 350 1.5 1495 1200 350 42 1/2 1.1/8 3,872.00W5504 HDD - 353 - 3R 10580 10066 3 x 350 2.34 2035 1200 350 53 5/8 1.1/8 4,410.00W5508 HDD - 353 - 6R 14080 13396 3 x 350 2.1 2035 1200 350 69 5/8 1.1/8 5,100.00
HSR Range W5002 HSR - 301 - 3R 1810 1722 1 x 300 0.48 874 405 476 17 1/2 5/8 814.82W5004 HSR - 301 - 4R 2090 1988 1 x 300 0.44 874 405 476 18 1/2 7/8 819.25W5006 HSR - 301 - 5R 2290 2179 1 x 300 0.41 874 405 476 19 1/2 7/8 901.58W5010 HSR - 302 - 3R 3650 3473 2 x 300 0.96 1376 405 476 26 1/2 7/8 1,180.47W5012 HSR - 302 - 4R 4220 4015 2 x 300 0.88 1376 405 476 29 1/2 7/8 1,290.99W5014 HSR - 302 - 5R 4600 4376 2 x 300 0.82 1376 405 476 31 1/2 7/8 1,189.31W5016 HSR - 303 - 3R 5490 5223 3 x 300 1.44 1884 405 476 35 1/2 1.1/8 1,306.46W5018 HSR - 303 - 4R 6340 6032 3 x 300 1.32 1884 405 476 39 1/2 1.1/8 1,762.80W5020 HSR - 303 - 5R 6910 6574 3 x 300 1.23 1884 405 476 42 1/2 1.1/8 1,703.51W5024 HSR - 352 - 4R 6540 6222 2 x 350 1.42 1455 405 581 38 1/2 1.1/8 2,133.89W5026 HSR - 352 - 6R 7700 7326 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 2,160.42W5028 HSR - 353 - 4R 9830 9352 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 2,465.47W5030 HSR - 353 - 6R 11580 11017 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 2,881.59W5032 HSR - 354 - 4R 13140 12501 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,094.79W5034 HSR - 354 - 6R 15440 14690 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 3,608.72
Partial Defrost OptionsW5200 HSR - 352 - 4R 6540 6222 2 x 350 1.42 1455 405 581 38 1/2 1.1/8 2,133.89W5202 HSR - 352 - 6R 7700 7326 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 2,160.42W5204 HSR - 353 - 4R 9830 9352 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 2,465.47W5206 HSR - 353 - 6R 11580 11017 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 2,881.59W5208 HSR - 354 - 4R 13140 12501 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,094.79W5210 HSR - 354 - 6R 15440 14690 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 3,608.72
HSR 3 Phase fansW5232 HSR - 502 - 4R 16650 15841 2 x 500 4.42 2230 555 690 132 5/8 1.3/8 5,342.84W5234 HSR - 502 - 6R 20290 19304 2 x 500 3.98 2230 555 690 143 7/8 1.3/8 5,388.72W5236 HSR - 503 - 4R 23810 22653 3 x 500 6.5 3000 555 690 200 7/8 2.1/8 6,172.72
CP217
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
HC EVAPORATOR RANGE
Realcold Low Temperature EvaporatorsRealcoldStock No.
Model Capacity @ 6KTD
Fans(mm)
Air Volume(M³ / Sec)
Dimensions (mm) Weight (Kg)
Connections System Price$ Excl. GST
R404a L W H Liquid Suction
HCT Range
W4604 HCT-252-2RE 970 2 x 250 0.28 750 450 177 5.2 3/8 3/8 740.21W4606 HCT-252-3RE 1210 2 x 250 0.24 750 450 177 7.8 1/2 1/2 613.71W4608 HCT-253-3RE 1820 3 x 250 0.36 1075 450 177 8.4 1/2 1/2 1,087.32W4610 HCT-254-3RE 2430 4 x 250 0.49 1400 450 177 11.7 1/2 1/2 1,412.47
HSR RangeW5054 HSR - 301 - 3RE 1810 1 x 300 0.48 874 405 476 17 1/2 5/8 1,062.20W5056 HSR - 301 - 4RE 2090 1 x 300 0.44 874 405 476 18 1/2 7/8 1,181.29W5058 HSR - 301 - 5RE 2290 1 x 300 0.41 874 405 476 19 1/2 7/8 1,262.25W5062 HSR - 302 - 3RE 3650 2 x 300 0.96 1376 405 476 26 1/2 7/8 1,481.33W5064 HSR - 302 - 4RE 4220 2 x 300 0.88 1376 405 476 29 1/2 7/8 1,644.73W5066 HSR - 302 - 5RE 4600 2 x 300 0.82 1376 405 476 31 1/2 7/8 1,705.69W5068 HSR - 303 - 3RE 5490 3 x 300 1.44 1884 405 476 35 1/2 1.1/8 2,069.34W5070 HSR - 303 - 4RE 6340 3 x 300 1.32 1884 405 476 39 1/2 1.1/8 2,233.46W5072 HSR - 303 - 5RE 6910 3 x 300 1.23 1884 405 476 42 1/2 1.1/8 2,465.39W5076 HSR - 352 - 6RE 7700 2 x 350 1.3 1455 405 581 44 1/2 1.1/8 3,079.63W5078 HSR - 353 - 4RE 9830 3 x 350 2.13 1972 405 581 51 5/8 1.1/8 3,045.92W5080 HSR - 353 - 6RE 11580 3 x 350 1.95 1972 405 581 61 5/8 1.1/8 3,586.75W5082 HSR - 354 - 4RE 13140 4 x 350 2.84 2540 405 581 65 5/8 1.3/8 3,769.33W5084 HSR - 354 - 6RE 15440 4 x 350 2.6 2540 405 581 78 5/8 1.3/8 4,374.61W5260 HSR - 502 - 4RE 16650 2 x 500* 4.42 2230 555 690 132 5/8 1.3/8 7,331.15W5262 HSR - 502 - 6RE 20290 2 x 500* 3.98 2230 555 690 143 7/8 1.3/8 7,626.59W5266 HSR - 503 - 4RE 23810 3 x 500* 6.5 3000 555 690 200 7/8 2.1/8 8,263.84
* Note: 3 phase fans.
For technical diagrams refer to page TD242
CP218
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
Hoshizaki Ice Machines
Save Water Consumption: Microcomputer automatically controls volume of water during the defrost cycle. Water inlet valve saves incoming water.
Bin Control Switch: When the bin is full of ice, bin control switch detects and automatically shuts down the ice making process. Reliable mechanical switch is fitted in cubers for consistent operation.
Smart Computer Board: No need for manual adjustments. Dependable Hoshizaki computer board controls ice supply in the most efficient and produc-tive way in any condition.
Sanitary Construction: One piece insulation, snug fit top cover, magnetic door gasket and door side protector prevents incoming dust, water and insects.
Long Life Main Parts: Main parts such as compressor, fan-motor, pump-motor are uniquely designed to ensure ice cubers ‘ long life.
Easily Cleaned Air-Filter: Air filter can be cleaned easily upon removing the front cover. Clean air-filter contributes to the maximum ice making production.
ICE MACHINES
CP219
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
ICE MACHINES
Hoshizaki Ice MachinesModel Production Capacity
(Kg/Day)Bin Capacity (Kg)
Amps Dimensions (mm) Net/Gross Weight (Kg)
System Price$ Excl. Gst
A.T.21°C W.T.15°C L W H
KM Crescent Ice - Self Contained (Cube Size 30 x 37 x 13)
KM 30A 32 16 1.5 610 450 850 39/49 POA
KM 50A 50 23 2.2 610 603 850 46/58 POA
KM 75A 70 40 3.0 712 603 850 51/64 POA
KM Crescent Ice - Stack On (Cube Size 38 x 27 x 13)
KM 630 MAH E * 283 n/a 7 695 560 950 75/84 POA
KM 1300 SAH E * 544 n/a 11.5 695 1220 695 125/143 POA
IM Cube Ice - Self Contained (Cube Size 25 x 25 x 23)
IM 30 CLE - 25 20 11.5 1.8 495 398 695 35/42 POA
IM 45 LE - 25 32 18 2.1 456 503 850 54/60 POA
IM 65 LE - 25 44 26 2.4 506 633 850 63/69 POA
IM Cube Ice - Self Contained (Cube Size 21 x 21 x 14)
IM 100 LE 83 50 5.0 506 704 1200 80/90 POA
IM 130 ME 104 50 5.0 506 704 1200 80/90 POA
IM 240 M2E 205 110 6.7 670 704 1577 130/145 POA
IM Cube Ice - Stack On (Cube Size 21 x 21 x 14)
IM 240 AME (* 230 n/a 6.7 800 560 865 90/110 POA
IM 240 DME (* 230 n/a 6.7 800 1084 395 90/95 POA
FM Flaked Ice - Self Contained
FM 120 EE 109 26 2.8 600 600 800 66/76 POA
FM 120 EE - 50 109 50 2.8 600 900 800 83/93 POA
FM Flaked Ice - Stack On
FM 251 AFE (* 200 n/a 5.6 700 560 680 86/98 POA
FM 481 AGE (* 425 n/a 6.8 699 560 780 97/118 POA
FM 600 AHE (* 540 n/a 9.9 699 560 780 110/122 POA
FM 1000 ASFE3 (** 950 n/a 8.8 698 760 898 153/168 POA
DCM Cubelet Ice & Water Dispenser (Size 15x9x19)
DCM 110F 105 4 3.2 585 350 840 60/67 POANote: A.T. = Ambient Temperature, W.T. = Water Temperature * Head only & bin sold separately. (* Bin sold separately. (** Bin sold separately, 3 phase 400V & remote air cooled condenser URC 20FE required (1200 x 370 x 659 mm)
Top KitsModel Net/Gross Weight (Kg) System Price
$ Excl. Gst
Top Kit 4H-100 mm B 800PF - IM 240AME, FM600, KM630, KM900, FM1000, 2 KM630, 2 FM600, 2 IM240AME B 900PF - KM1300
POA
Top Kit 8H-200 mm B 500PF - IM 240AME, FM600, KM630 B 900PF - IM 240AME, FM600, KM630, 2 KM630, 2 FM600, 2 IM240AME
POA
Top Kit 14H-355 mm B 700PF & B 800PF - KM900, FM1000. POA
Top Kit 22H-560 mm B 700PF & B 800PF - IM 240AME, FM600, KM630 B 900PF - IM 240AME, FM600, KM630, KM900, FM1000
POA
Note: Kits are use to fill the gap large “B Series” bins leave when used with head only units.
CP220
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
ICE MACHINES
Optional Bins - Insulated, Vinyl Clad Galvanized Steel, Stainless Steel BinsModel Capacity (Kg) Compatible With Dimensions * System Price
$ Excl. GstL W H
P 200SD2 180 IM 240 DME 1080 850 800 POA
N 200A 95 IM 240 DME Bin Extension: Height = 475 POA
B 300PF 140 IM 240 AME
KM 630 MAH-E
FM 600 AHE /
FM 481
560 820 1168 POA
B 500PF 230 IM 240 AME
KM 630 MAH-E
KM 900 MAH-E
FM 600 AHE /
FM 481
FM 1000 ASFE
760 820 1168 POA
B 800PF 365 IM 240 AME
KM 630 MAH-E
KM 900 MAH-E
KM 1300 SAH-E
FM 600 AHE /
FM 481
FM 1000 ASFE
1220 820 1168 POA
B 900PF 410 IM 240 AME
KM 630 MAH-E
KM 900 MAH-E
KM 1300 SAH-E
FM 600 AHE /
FM 481
FM 1000 ASFE
1320 820 1168 POA
* Height includes adjustable feet 150-180 mm. Indent only, POA.
CP221
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
Geneglace Flake Ice Machines
What Is Flake Ice? Flake-ice is small ice in flat pieces. It is used in cooling seafood, in meat processing
and in a whole range of industrial processes. Flake-ice is dry and sub-cooled (-6°C approx). With a moderate production cost compared to most of the other kinds of ice, flake-ice is used in large quanti-ties in many industrial and food processes.
Substantial Cooling Power: Slightly sub-cooled, flake-ice is also a dry ice. The “ ice only “ feature of its manufacture means that the latent heat, the principal source of the cooling energy, is 100 % available.
Accurate Cooling: As flake-ice is dry, its cooling input can be accurately calculated and its effects on the temperature of the mixture are quickly apparent.
Easy Handling And Storage: Flake-ice is free flowing, its flakes do not stick together and form blocks. They are light and cushion the product to reduce the risk of crushing or deterioration.
The Realcold Complete Unit consists of:
• Low Temp Condensing Unit, fully connected to the Ice Generator
• Built on its own steel frame
• Fully wired package to its own control panel
• Salt Dose Pump Kit (if required)
• Unit evacuated and charged with dry nitrogen
Site Requirements:
• Refrigerant Charge
• 3 Phase electrical supply
• Fresh water supply
• Full commissioning
GENEGLACE FLAKE ICE MACHINES
Geneglace Ice Generator - InformationRealcoldStock No.
Model Water Conditions 24 HourIce Production (Kg)
Refrigerator Liquid Inlet Dimensions (mm) Net Weight (Kg)
Base Dim. (mm)
Dia. Ice Outlet (mm)
L W H
C6230 F15 Fresh water entering +15°C
350-480 R22, R404a Expansion Valve
520 360 600 50 390 x 360 240
C6232 F30V Fresh water entering +15°C
500-1000 650 500 700 90 500 x 470 340
C6234 F90H Fresh water entering +15°C
1500-3000 910 750 1250 210 680 x 680 500
C6236 F90V Fresh water entering +15°C
2700-3700 910 750 1250 210 680 x 680 500
C6240 F200 Fresh water entering +15°C
4200-7300 R22, R717,
R404a
Expansion Valve or Liquid Level Control
1200 950 1750 550 910 x 910 680
C6246 F250 Fresh water entering +15°C
6200-10000 1300 1000 2050 720 910 x 910 680
C6254 F600 Fresh water entering +15°C
7500-14000 R22, R717,
R404a
Liquid Level Control
1500 1200 2050 950 1040 x 1040 780
C6258 F800 Fresh water entering +15°C
12500-21000 1550 1550 3000 2500 1290 x 1290 930
C6262 F900 Fresh water entering +15°C
17000-30000 1950 1950 3100 3100 1580 x 1580 1200
C6268 F2000 Fresh water entering +5°C
26000-48000 2435 2435 3100 5200 2080 x 2080 1780
Note: ABF Models are for use with High Pressure Liquid, such as a TX Valve system, and include a Flood Bottle. SBF Models are for use with pumped circulation system and does not include a Flood Bottle. Salt dosing kit is common to all models. Indent only, POA.
CP222
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
CHILLED WATER PACKAGES
Chilled Water Packages Feature
• Realcold packaged liquid chillers are individually custom designed and built to meet customer requirements for each application. Integral, remote air or remote water cooled condensing is available
• Industrial type construction
• Engineered for HFC and HCFC refrigerants
• Water or glycol applications
• Self contained, complete with integral operating controls and safety devices
• Fractional HP through to large screw compressor packages
Custom Design & Build Service
Realcold offer a complete design and build facility for chilled water packages.
To assist our Technical Sales Staff in providing the best solution for your chiller and/or process needs please use the following information guide when forwarding your request. This will help ensure the best possible design and quotation is offered to you. Please do not hesitate to contact our staff should you have any queries or wish to discuss possible design options:
Ambient conditions - °C
Application - What is chiller to be used for?
Buffer tank required - Yes / No, Size?
Condensing - Water or Air cooled?
Coolant pumps - Primary and / or secondary
Coolant type - Water, Glycol, oil, other
Cooling Capacity - kW
Electrical - Level of electrical controls and safeties required.
Expected load variation - Max and minimum load percentage
Heat Exchanger type - Plate, Shell and Tube, Open type
Hygiene requirements - SS pipe, fittings, tank etc
Refrigerant - R404a, R507, R22, R134a, R407c, etc
Required flow rates - L/s, m³/hr, Kg/s
Required Temperature - Coolant supply and return temperatures
Unit location - Indoor or outdoor?
CP223
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Cap
ital P
lant
COMPRESSOR AND CONDENSING UNIT WARRANTY
CompressorsRealcold Ltd standard warranty covers start up of all compres-sors. For extended warranty the following charges apply:
Extended Warranty Charges
Sealed Compressors - All brands - 4% on sale price
Semi-Sealed Compressors - All brands - 4% on sale price
Compressors will be repaired or replaced under warranty if re-turned within 12 months of purchase date, provided that com-pressor, complete with original electrics, is returned to point of purchase, freight paid, accompanied by a compressor failure report.
Realcold Ltd shall not be held responsible for failure or damage resulting from misuse or incorrect installation.
Condensing UnitsSealed & Semi-Sealed
Warranty is included in the price listed for condensing units and includes replacement of all components for a 12 month period from date of purchase, provided component is returned along with Goods Returned Form to point of purchase, freight paid.
Note:
Replacement components will be debited against the account of the purchaser, with credit to follow upon receipt and inspection of faulty component.
Realcold Ltd shall in no event be liable for any indirect or conse-quential loss or damage whatsoever.
Refer to the back of this catalogue for our General Terms of Trade. Goods Returned Forms are available from your representative, or any of our branches.
Compressor & Condensing Unit Warranty
TDTD225
Tech
nica
l Dat
a
Technical DataEasypack Condensing Unit TD226
Medium Temp R404a TD226Medium Temp R134a TD226Low Temp R404a TD226
Sealed Condensing Unit Data TD227Copeland Scroll Sealed Units TD227Realpack Units TD227
Semi-Sealed Condensing Unit Data TD228Medium Temp R404a TD228Low Temp R404a TD228
Condensing Unit Capacity Tables TD231Medium Temp R404a TD231Medium Temp R134a TD231Low Temp R404a TD232
Semi-Hermetic Condensing Unit Capacity Tables TD233Medium Temp R404a TD233Low Temp R404a TD234
Standard Air Cooled Condensers TD235
Evaporator Data TD238Medium Temp TD238Low Temp TD239
Cooling Units TD240
HCT Range Unit Coolers TD242
Rondo Range Unit Coolers TD243
HDD Range Dual Discharge Coolers TD244
HSR Range Unit Coolers TD245
Small Coolroom Capacities TD246
Refrigeration Terminology TD247
Technical Tips TD248
Evaporation Superheat TD249
A Guide To Calculating Noise Levels TD250
Metric Conversion Chart TD251
General Rules & First Aid TD252
Pressure Temperature Chart TD253
Properties Of Refrigerants TD254
Conversion Data TD255
TD226
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
EASYPACK CONDENSING UNITM
odel
N
umbe
rC
ompr
esso
r M
odel
Hor
se
Pow
erD
imen
sion
s (m
m)
L x
W x
H C
apac
ity (W
), A
mbi
ent 3
2°C
Fan
(mm
)Li
quid
(m
m)
Suct
ion
(mm
)W
eigh
t (K
g)So
und
leve
l dBA
240V
-50H
z40
0V-5
0Hz
-10
-50
510
In (A
)Im
(A)
In (A
)Im
(A)
Med
ium
Tem
p R4
04a
C07
57E
CA
J 95
13 Z
1 1/
855
0 x
650
x 46
521
0824
0528
0732
2036
351
x 35
015
.99.
547
767.
310
.9-
-
C07
58E
CA
J 45
17 Z
1 1/
460
0 x
600
x 56
022
7228
4531
6836
3441
001
x 40
015
.99.
560
777.
811
.5-
-
C07
59E
CA
J 45
19 Z
1 1/
260
0 x
600
x 56
025
2636
3842
4148
6454
991
x 40
015
.99.
560
7910
.716
--
C07
62E
FH 4
524
Z2
600
x 60
0 x
560
3586
4291
5023
5786
6587
1 x
400
15.9
9.5
7379
11.7
19-
-
C07
64E
FH 4
531
Z2
1/2
600
x 60
0 x
560
4855
5850
6764
7754
8767
1 x
400
22.2
9.5
7679
14.9
27-
-
C09
54E
TFH
452
4 Z
260
0 x
600
x 56
035
8642
9150
2357
8665
871
x 40
015
.99.
573
79-
-4.
776.
77
C09
60E
TFH
453
1 Z
2 1/
260
0 x
600
x 56
048
5558
5067
6477
5487
671
x 40
022
.29.
576
82-
-5.
778.
67
C09
64E
TFH
454
0 Z
360
0 x
600
x 56
056
2867
4079
0891
4910
481
1 x
400
22.2
12.7
8082
--
8.1
9.7
C09
68E
TAG
455
3 Z
4 1/
210
80 x
680
x 5
6573
3289
4810
685
1250
914
387
2 x
400
22.2
12.7
118
84-
-8.
7514
.35
C09
71E
TAG
456
1 Z
510
80 x
680
x 5
6575
6797
1311
323
1336
515
382
2 x
400
28.6
12.7
118
84-
-10
15
C09
73E
TAG
457
3 Z
6 1/
410
80 x
680
x 5
6510
023
1203
414
168
1642
618
808
2 x
400
28.6
12.7
135
84-
-12
.35
19
C09
77E
2 xT
AG
P 45
53 Z
914
20 x
730
x 8
7013
946
1710
420
605
2420
727
667
2 x
500
28.6
15.9
213
87-
-16
.225
.5
C09
80E
2 xT
AG
P 45
61 Z
1014
20 x
730
x 8
7016
904
2022
523
683
2727
831
010
2 x
500
28.6
15.9
218
87-
-19
.525
.5
C09
85E
2 xT
AG
P 45
73 Z
1214
20 x
730
x 8
7022
356
2597
430
077
3466
539
738
2 x
500
28.6
15.9
218
87-
-23
.939
Med
ium
Tem
p R1
34a
Cap
acity
(W),
Am
bien
t 32°
C
-10
-50
510
C07
33E
FH 4
518
Y1
1/2
600
x 60
0 x
560
2514
3151
3904
4773
5759
1 x
400
15.9
9.5
7376
7.15
14.5
--
C07
37E
FH 4
525
Y2
600
x 60
0 x
560
3258
4130
5072
6131
7352
1 x
400
15.9
9.5
7878
9.15
16.5
--
Low
Tem
p R4
04a
Cap
acity
(W),
Am
bien
t 32°
C
-30
-25
-20
-15
-10
C07
87E
CA
J 24
64 Z
1 1/
255
0 x
650
x 39
511
8414
9518
4022
1226
081
x 35
015
.99.
540
766.
110
.5-
-
C07
89E
FH 2
480
Z2
600
x 60
0 x
560
1800
2271
2746
3225
3709
1 x
400
15.9
9.5
7379
8.1
17-
-
C07
93E
TFH
251
1 Z
360
0 x
600
x 56
023
5630
3037
6745
6654
271
x 40
015
.99.
580
82-
-3.
86
C07
94E
TAG
251
6 Z
410
80 x
680
x 5
6532
6841
8851
8862
6974
302
x 40
022
.29.
510
781
--
5.4
10.5
7
C07
95E
TAG
252
2 Z
510
80 x
680
x 5
6542
0254
0166
7480
1994
382
x 40
022
.29.
510
781
--
7.04
13.4
5
C07
96E
2 xT
FHP
2511
Z6
1080
x 8
00 x
570
4633
5921
7296
8619
1000
62
x 40
028
.69.
515
681
--
6.7
9.4
C07
97E
2 xT
AG
P 25
16 Z
814
20 x
730
x 8
7065
0884
1710
540
1287
815
430
2 x
500
22.2
9.5
210
82-
-11
.320
.8
C07
98E
2 xT
AG
P 25
22 Z
1014
20 x
730
x 8
7077
1398
5012
220
1482
217
658
2 x
500
28.6
15.9
215
83-
-13
.929
.5
TD227
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
SEALED CONDENSING UNIT DATA
Cop
ela
nd S
crol
l Sea
led
Uni
tsM
odel
N
umbe
rC
ompr
esso
r M
odel
Hor
se
Pow
erC
ompr
esso
r W
eigh
t (K
g)40
0V
(FLA
)C
apac
ity
R404
a (k
W)
Dis
p
(m³/
hr)
Con
dens
erC
onde
nser
Fan
sRe
ceiv
erBa
se
Mod
elD
imen
sion
s (m
m)
Mod
elH
OR
W @
15KT
DFa
ns
No
Volts
Fan
dia
(mm
)A
ir Flo
w
(L/s
)M
odel
Dia
x L
Litr
esPr
ess
Rele
ifL
WH
Med
ium
Tem
p R4
04a
SST
- 5C
CM
TZ40
0ZB
30K
QE-
TFD
441
10.3
8.53
11.8
SCS2
150
1500
02
230
350
1560
SFRH
215
0 X
800
940
0SF
B410
5291
451
9C
MTZ
500
ZB38
KQ
E-TF
D5
4212
.810
.43
14.5
SCT2
170
1700
02
230
400
2960
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
CM
TZ60
0ZB
45K
QE-
TFD
644
13.1
12.4
617
.2SC
T221
522
150
223
040
027
80SF
RH3
150
X 1
200
1440
0SF
B512
6991
472
3C
MTZ
750
ZB58
KQ
E-TF
D7.
510
015
.413
.85
20.9
SCT2
215
2215
02
230
400
2600
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
CM
TZ10
00ZB
76K
QE-
TFD
1010
221
.719
.86
28.9
SCR2
275
2750
02
230
500
3730
SFRH
315
0 X
120
014
400
SFB6
1484
1034
775
CM
TZ13
00ZB
92K
CE-
TWD
1311
225
.125
.29
35.6
SCR2
385
3850
02
230
500
3900
SFRH
315
0 X
120
014
400
SFB6
1484
1034
928
CM
TZ15
00ZB
11M
CE-
TWD
1512
029
.230
.96
42.1
SCR2
475
4750
02
230
500
3520
SFRH
315
0 X
120
014
400
SFB6
1484
1034
1028
Low
Tem
p R4
04a
SST
- 25
CC
LTZ
600
ZF18
K4E
-TFD
644
125.
8517
.2SC
S215
015
000
223
035
015
60SF
RH2
150
X 8
009
400
SFB4
1052
914
723
CLT
Z75
0ZF
24K
4E-T
FD7.
510
016
.17.
1120
.9SC
T217
017
000
223
040
029
60SF
RH3
150
X 1
200
1440
0SF
B512
6991
472
3C
LTZ
1000
ZF33
K4E
-TFD
1010
222
.39.
6728
.9SC
T221
521
500
223
040
027
80SF
RH3
150
X 1
200
1440
0SF
B512
6991
472
3C
LTZ
1300
ZF40
K4E
-TFD
1311
225
.112
.09
35.6
SCR2
275
2750
02
230
500
3730
SFRH
315
0 X
120
014
400
SFB6
1484
1034
776
CLT
Z15
00ZF
48K
4E-T
FD15
120
30.6
14.9
542
.1SC
R238
538
500
223
050
039
00SF
RH3
150
X 1
200
1440
0SF
B614
8410
3492
8
Rea
lpa
ck U
nits
Mod
el
Num
ber
Com
pres
sor
Mod
elH
orse
Po
wer
Com
pres
sor
230/
400V
(F
LA)
Volts
Pha
seC
apac
ity
R404
a (W
atts
)
Dis
p
(m³/
hr)
Con
dens
er F
ans
Liqui
d Re
ceiv
er
Capa
city
Kg
@ 8
0%
Net
t W
eigh
t (K
g)
Line
Siz
e (m
m)
Dim
ensi
ons
(mm
)So
und
Pow
er
Leve
l dB
A
Fans
N
o23
0V
MRA
Fan
dia
(mm
)A
ir Flo
w
(L/s
)Su
ctio
nLi
quid
Leng
thD
epth
Hei
ght
Med
ium
Tem
p R4
04a
SST
- 5C
RPM
125
CA
J451
7Z1.
257.
124
0V 1
PH28
6325
.95
10.
3730
039
92.
371
5/8"
3/8"
1070
480
750
65
RPM
150
CA
J451
9Z1.
59.
924
0V 1
PH37
8334
.45
10.
735
077
82.
371
5/8"
3/8"
1070
480
750
68
RPM
200
FH45
24Z
210
.324
0V 1
PH44
6043
.51
0.7
350
778
3.9
815/
8"3/
8"10
7048
075
070
RPM
250
TFH
4531
Z2.
56.
541
5V 3
PH58
1356
.65
22
x 0.
3730
085
66
105
5/8"
3/8"
1285
625
820
69
RPM
300
TFH
4540
Z3
8.9
415V
3PH
7571
74.2
52
2 x
0.7
350
1459
611
85/
8"3/
8"12
8562
582
075
RPM
450
TAG
4553
Z4.
59.
841
5V 3
PH88
5510
0.7
22
x 0.
735
014
599.
514
67/
8"1/
2"12
8562
582
078
RPM
500
TAG
4561
Z5
11.4
415V
3PH
1044
611
2.5
22
x 0.
735
014
029.
514
87/
8"1/
2"12
8562
582
078
RPM
600
TAG
4573
Z6
14.3
415V
3PH
1334
613
4.8
22
x 0.
735
014
029.
515
07/
8"1/
2"12
8562
582
077
RPM
750
2x T
AG
P454
6Z7.
52
x 8.
541
5V 3
PH15
690
2 x
90.2
22
x 3
500
3450
1225
81
1/8"
5/8"
1660
790
1015
83
RPM
100
02x
TA
GP4
561Z
102
x 11
.441
5V 3
PH20
892
2 x
112.
502
2 x
350
034
5012
261
1 1/
8"5/
8"16
6079
010
1583
RPM
125
02x
TA
GP4
573Z
122
x 14
.341
5V 3
PH26
692
2 x
134.
802
2 x
350
034
5012
265
1 1/
8"5/
8"16
6079
010
1582
Low
Tem
p R4
04a
SST
- 25
CRP
L 20
0FH
2480
Z2
11.5
240V
1PH
2296
53.2
10.
735
077
83.
990
5/8"
3/8"
1070
480
750
69
RPL
300
TFH
2511
Z3
5.1
415V
3PH
3206
74.3
22
x 0.
3730
085
66
130
5/8"
3/8"
1285
625
820
72
RPL
400
TAG
2516
Z4
7.3
415V
3PH
4498
112.
52
2 x
0.7
350
1459
615
57/
8"1/
2"12
8562
582
071
RPL
500
TAG
2522
Z5
9.4
415V
3PH
5746
134.
82
2 x
0.7
350
1402
9.5
175
7/8"
1/2"
1285
625
820
76
RPL
800
2x T
AG
P251
6Z8
2 x
7.3
415V
3PH
8874
2 x
112.
502
2 x
350
034
5012
258
1 1/
8"5/
8"16
6079
010
1579
RPL
1000
2x T
AG
P252
2Z10
2 x
9.4
415V
3PH
1169
32
x 13
4.80
22
x 3
500
3450
1225
81
1/8"
5/8"
1660
790
1015
81N
ote:
Cus
tom
des
ign
units
ava
ilabl
e fo
r spe
cial
ist a
pplic
atio
ns.
TD228
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
SEMI-SEALED CONDENSING UNIT DATAFr
asc
old
Sem
i-Se
ale
d U
nits
Mod
el
Num
ber
Com
pres
sor
Mod
elH
orse
Po
wer
Com
pres
sor
Wei
ght (
Kg)
400V
FL
AC
apac
ity
R404
a (k
W)
Dis
p
(m³/
hr)
Con
dens
erC
onde
nser
Fan
sRe
ceiv
erBa
se
Mod
elD
imen
sion
s (m
m)
Mod
elH
OR
W @
15KT
DFa
ns
No
Volts
Fan
dia
(mm
)A
ir Fl
ow
(L/s
)M
odel
Dia
x L
Litr
esPr
ess
Rele
ifL
WH
Med
ium
Tem
p R4
04a
SST
- 5C
SAR1
57A
A1.
57Y
1,5
365,
341
006,
91SC
S158
5800
123
035
081
0SF
RHI
150
X 4
005
400
SFB3
649
974
519
SAR2
10B
B21.
0Y2
385,
760
909,
84SC
T189
8900
123
040
081
0SF
RH1
150
X 4
005
400
SFB3
665
974
620
SAR3
13D
D31
3Y3
499,
681
5013
,84
SCT1
120
1200
01
230
400
1080
SFRH
115
0 X
400
540
0SF
B310
5297
462
0
SAR4
18D
D41
8Y4
5110
,599
9017
,83
SCT2
170
1700
02
230
400
2960
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
SAR5
24F
F424
Y5
7612
,214
790
23,6
SCT2
215
2215
02
230
400
2780
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
SAR7
28Q
Q72
8Y7,
579
17,5
1711
027
,31
SCT2
215
2215
02
230
400
2600
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
SAR7
33S
S733
Y7,
511
717
,520
690
32,8
SCR2
275
2750
02
230
500
3730
SFRH
315
0 X
120
014
400
SFB6
1484
1034
775
SAR1
039S
S103
9Y10
120
2123
650
38,2
5SC
R238
538
500
223
050
039
00SF
RH3
150
X 1
200
1440
0SF
B614
8410
3492
8
SAR1
551S
S155
1S15
126
3130
910
50,4
3SC
R247
547
500
223
050
035
20SF
RH3
150
X 1
200
1440
0SF
B614
8410
3410
28
SAR2
059V
V205
9Y20
174
3736
710
58,4
8SC
V272
072
000
240
063
068
20SF
RH4
150
X 1
900
3040
0SF
B721
5410
9696
5
SAR2
571V
V257
1Y25
184
4544
540
70,9
7SC
V272
072
000
240
063
068
20SF
RH4
150
X 1
900
3040
0SF
B721
5410
9696
5
SAR3
084V
V308
4Y30
187
5353
000
83,8
1SC
V285
085
000
240
063
060
60SF
RH4
150
X 1
900
3040
0SF
B721
5410
9610
65
SAR3
5106
ZZ3
5106
Y35
223
6163
410
106,
16SC
V285
085
000
240
063
060
60SF
RH4
150
X 1
900
3040
0SF
B721
5410
9610
65
Low
Tem
p R4
04a
SST
- 25
C
SAR1
59B
B159
Y1,
538
5,3
2320
8,96
SCS1
5858
001
230
350
810
SFRH
115
0 X
400
540
0SF
B364
997
451
9
SAR2
13D
D21
3Y2
456,
835
5013
,84
SCT1
8989
001
230
400
810
SFRH
115
0 X
400
540
0SF
B364
997
462
0
SAR3
18D
D31
8Y3
499,
648
5017
,83
SCT1
120
1200
01
230
400
1080
SFRH
215
0 X
800
940
0SF
B464
997
462
0
SAR4
24F
F424
Y4
7410
,965
8023
,6SC
S215
015
000
223
035
015
60SF
RH2
150
X 8
009
400
SFB4
1052
914
723
SAR5
28Q
Q52
8Y5
7612
,274
3027
,31
SCS2
150
1500
02
230
350
1560
SFRH
215
0 X
800
940
0SF
B410
5291
451
9
SAR7
33S
S733
Y7,
511
717
,588
0032
,8SC
T217
017
000
223
040
029
60SF
RH3
150
X 1
200
1440
0SF
B512
6991
472
3
SAR7
39S
S739
Y7,
511
717
1082
038
,25
SCT2
215
2150
02
230
400
2780
SFRH
315
0 X
120
014
400
SFB5
1269
914
723
SAR1
051S
S105
1Y10
120
2114
080
50,4
3SC
T225
525
500
223
040
026
00SF
RH3
150
X 1
200
1440
0SF
B512
6991
472
3
SAR1
559V
V155
9Y15
170
3115
700
58,4
8SC
R227
527
500
223
050
037
30SF
RH3
150
X 1
200
1440
0SF
B614
8410
3477
6
SAR1
571V
V157
1Y15
170
3119
380
70,7
7SC
R238
538
500
223
050
039
00SF
RH3
150
X 1
200
1440
0SF
B614
8410
3492
8
SAR2
084V
V208
4Y20
180
3722
500
83,8
1SC
R247
547
500
223
050
035
20SF
RH3
150
X 1
200
1440
0SF
B614
8410
3410
28
SAR2
5106
ZZ2
5106
Y25
220
4529
350
106,
16SC
V272
072
000
240
063
068
20SF
RH4
150
X 1
900
1440
0SF
B721
5410
9696
5
SAR3
0126
ZZ3
0126
Y30
229
5335
020
125,
72SC
V285
085
000
240
063
060
60SF
RH4
150
X 1
900
1440
0SF
B721
5410
9610
65
SAR4
0154
ZZ4
0145
Y40
240
7541
660
154,
38SC
V285
085
000
240
063
060
60SF
RH4
150
X 1
900
1440
0SF
B721
5410
9610
65
Medium Temp R404aLow Temp R404a
TD229
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
BASES & CONDENSERS - SCS / SCT / SCR
SCS 2_ _
SCT 2_ _
SCR 2275
SCT 1_ _
TD230
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
BASES & CONDENSERS - SCR / SCV
SCR 2385
SCV 2720
SCV 2850
SCR 2475
TD231
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
CONDENSING UNIT CAPACITY TABLES
Realcold Hermetic Condensing UnitsModel Number
5 0 -5 -10 -15 -20 -25 -30 -35 -40
Medium Temp R404a
RMTZ100 capacity 2450 2117 1791 1495 1222 983 - - - -
input power 1092 996 909 832 765 708 - - - -
RMTZ112 capacity 3138 2669 2231 1825 1456 1123 828 - - -
input power 1335 1226 1116 1004 890 775 658 - - -
RMTZ125 capacity 3819 3256 2728 2246 1820 1464 - - - -
input power 1429 1310 1196 1103 1016 939 - - - -
RMTZ150 capacity 4848 4167 3512 2893 2324 1817 - - - -
input power 2035 1856 1698 1563 1454 1359 - - - -
RMTZ200 capacity 5251 4422 3663 2973 2349 1790 - - - -
input power 2331 2112 1908 1715 1528 1335 - - - -
RMTZ250 capacity 7153 6053 5046 4115 3245 2421 - - - -
input power 2958 2704 2454 2206 1951 1681 - - - -
Medium Temp R404a 5 0 -5 -10 -15 -20 -25 -30 -35 -40
RMTXZ250 capacity 7108 5980 4967 4043 3221 2490 - - - -
input power 2866 2595 2344 2107 1880 1656 - - - -
RMTXZ300 capacity 9145 7716 6422 5256 4214 3289 - - - -
input power 3821 3464 3134 2827 2536 2258 - - - -
RMTXZ450 capacity 10698 9370 7724 6223 4878 3693 - - - -
input power 4708 4229 3755 3313 2886 2471 - - - -
RMTXZ500 capacity 13823 11435 9306 7428 5789 4378 - - - -
input power 5223 4677 4174 3702 3254 2817 - - - -
RMTXZ600 capacity 15526 13120 10931 8961 7193 5639 - - - -
input power 6703 5961 5284 4662 4085 3548 - - - -
RMTXZ900 capacity 21396 18740 15448 12446 9756 7386 - - - -
input power 9416 8458 7510 6626 5772 4942 - - - -
RMTXZ1000 capacity 27646 22870 18612 14856 11578 8756 - - - -
input power 10446 9354 8348 7404 6508 5634 - - - -
RMTXZ1200 capacity 31052 26240 21862 17922 14386 11278 - - - -
input power 13406 11922 10568 9324 8170 7096 - - - -
Medium Temp R134a 5 0 -5 -10 -15 -20 -25 -30 -35 -40
RMTY100 capacity 2933 2448 1996 1588 1230 930 - - - -
input power 1081 965 855 746 633 512 - - - -
RMTY150 capacity 4322 3568 2837 2136 1472 854 - - - -
input power 1594 1401 1223 1050 877 697 - - - -
RMTY200 capacity 5550 4613 3739 2957 2277 1736 - - - -
input power 2152 1881 1652 1452 1270 1095 - - - -
Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.
TD232
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
CONDENSING UNIT CAPACITY TABLES
Model Number
5 0 -5 -10 -15 -20 -25 -30 -35 -40
Low Temp R404a
RLT100 capacity - - - 1762 1474 1210 979 789 644 -
input power - - - 1200 1068 959 870 801 749 -
RLTZ150 capacity - - - 2533 2112 1732 1402 1125 907 -
input power - - - 1584 1425 1290 1181 1095 1028 -
RLTZ200 capacity - - - 3544 2913 2336 1817 1359 958 -
input power - - - 2489 2180 1913 1680 1480 1315 -
RLTZ300 capacity - - - 5176 4257 3431 2720 2145 1717 1443
input power - - - 2873 2535 2249 2014 1823 1670 1550
RLTZ400 capacity - - - 7255 5955 4769 3723 2853 2181 1718
input power - - - 4331 3764 3280 2871 2528 2241 1997
RLTZ500 capacity - - - 8945 7389 5973 4737 3717 2938 2423
input power - - - 5130 4480 3939 3498 3153 2897 2687
RLTZ600 capacity - - - 10352 8514 6862 5440 4290 3434 -
input power - - - 5746 5070 4498 4028 3646 3340 -
RLTZ800 capacity - - - 14510 11910 9538 7446 5706 4362 3436
input power - - - 8662 7528 6560 5742 5056 4482 3994
RLTZ1000 capacity - - - 17890 14778 11946 9474 7434 5876 4846
input power - - - 10260 8960 7878 6996 6306 5794 5374
Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.
TD233
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
SEMI-HERMETIC CONDENSING UNIT CAPACITY TABLES
Model Number
5 0 -5 -10 -15 -20 -25 -30 -35 -40
Medium Temp R404a
SAR16A capacity 4.46 3.84 3.27 2.75 2.28 1.86 1.48 1.16 0,87 -
input power 1.82 1.61 1.42 1.26 1.10 0.97 0.85 0.75 0,65 -
SAR157 capacity 5.60 4.82 4.10 3.46 2.86 2.33 1.86 1.46 1,10 -
input power 2.08 1.88 1.67 1.50 1.33 1.18 1.05 0.94 0,81 -
SAR210 capacity 8.34 7.17 6.09 5.12 4.24 3.46 2.77 2.18 - -
input power 3.08 2.85 2.62 2.41 2.21 2.01 1.82 1.64 - -
SAR313 capacity 11.15 9.59 8.15 6.86 5.68 4.64 3.71 2.92 - -
input power 4.42 3.99 3.60 3.25 2.91 2.60 2.31 2.04 - -
SAR416 capacity 13.61 11.73 9.99 8.44 7.02 5.76 4.64 3.68 - -
input power 5.13 4.64 4.19 3.79 3.40 3.04 2.70 2.39 - -
SAR519 capacity 16.19 13.95 11.89 10.06 8.37 6.89 5.57 4.43 - -
input power 5.71 5.22 4.75 4.32 3.91 3.53 3.16 2.82 - -
SAR524 capacity 20.06 17.32 14.79 12.53 10.45 8.62 6.99 5.59 - -
input power 7.42 6.69 6.01 5.44 4.90 4.41 3.94 3.54 - -
SAR728 capacity 23.39 20.11 17.11 14.44 12.01 9.86 7.96 6.33 - -
input power 7.96 7.33 6.71 6.14 5.55 4.99 4.44 3.94 - -
SAR733 capacity 28.45 24.40 20.69 17.41 14.42 11.78 9.45 7.47 - -
input power 9.50 8.69 7.89 7.17 6.44 5.77 5.11 4.51 - -
SAR1039 capacity 32.06 27.69 23.65 20.05 16.73 13.80 11.19 8.95 - -
input power 11.45 10.38 9.36 8.45 7.57 6.76 5.98 5.29 - -
SAR1551 capacity 42.19 36.31 30.91 26.10 21.69 17.79 14.32 11.36 - -
input power 14.54 13.18 11.85 10.66 9.51 8.48 7.49 6.60 - -
SAR2059 capacity 50.21 43.17 36.71 30.96 25.69 21.03 16.90 13.38 - -
input power 16.80 15.14 13.56 12.17 10.88 9.75 8.64 7.62 - -
SAR2571 capacity 61.31 52.54 44.54 37.48 31.04 25.38 20.36 16.11 - -
input power 20.13 18.31 16.53 14.89 13.27 11.78 10.36 9.08 - -
SAR3084 capacity 72.67 62.38 53.00 44.69 37.12 30.45 24.55 19.52 - -
input power 24.88 22.53 20.25 18.16 16.09 14.19 12.38 10.78 - -
SAR35106 capacity 85.87 74.21 63.41 53.70 44.76 36.80 29.69 23.57 - -
input power 32.91 29.49 26.32 23.47 20.69 18.16 15.79 13.74 - -
Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.
TD234
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
SEMI-HERMETIC CONDENSING UNIT CAPACITY TABLES
Model Number
5 0 -5 -10 -15 -20 -25 -30 -35 -40
Low Temp R404a
SAR159 capacity - 5.66 4.88 4.16 3.49 2.87 2.32 1.83 1.39 -
input power - 2.92 2.53 2.22 1.94 1.68 1.45 1.25 1.07 -
SAR213 capacity - - 7.45 6.34 5.32 4.39 3.55 2.82 2.16 -
input power - - 4.13 3.58 3.10 2.70 2.33 2.00 1.70 -
SAR318 capacity - - 10.00 8.54 7.18 5.95 4.85 3.90 3.04 2.33
input power - - 5.01 4.41 3.89 3.44 3.03 2.67 2.34 2.04
SAR424 capacity - - - 11.37 9.62 8.02 6.58 5.32 4.20 3.24
input power - - - 5.99 5.28 4.67 4.11 3.62 3.16 2.75
SAR728 capacity 20.30 17.72 15.28 13.06 10.98 9.11 7.43 5.96 - -
input power 8.80 7.95 7.17 6.47 5.78 5.14 4.53 3.99 - -
SAR733 capacity 24.56 21.40 18.41 15.69 13.16 10.87 8.80 7.01 - -
input power 10.68 9.54 8.50 7.60 6.73 5.95 5.22 4.56 - -
SAR739 capacity - - - 18.85 15.89 13.22 10.82 8.74 6.89 5.31
input power - - - 9.28 8.21 7.27 6.38 5.59 4.85 4.18
SAR1051 capacity - - - 24.68 20.74 17.24 14.08 11.33 8.89 6.81
input power - - - 12.26 10.69 9.36 8.13 7.06 6.05 5.16
SAR1559 capacity - - 31.50 27.12 22.97 19.17 15.70 12.64 9.90 7.56
input power - - 16.21 14.18 12.28 10.63 9.13 7.86 6.69 5.67
SAR1571 capacity - - - 34.09 28.62 23.77 19.38 15.54 12.13 9.21
input power - - - 17.26 14.97 13.01 11.18 9.60 8.15 6.88
SAR2084 capacity - - - 38.36 32.51 27.29 22.50 18.28 14.48 11.23
input power - - - 20.77 17.88 15.41 13.20 11.35 9.81 8.43
SAR25106 capacity - - - 52.00 43.56 36.08 29.35 23.52 18.34 13.94
input power - - - 25.12 21.89 19.13 16.53 14.22 12.07 10.17
SAR30126 capacity - - - - 51.87 43.01 35.02 28.10 21.94 16.71
input power - - - - 26.86 23.48 20.29 17.43 14.71 12.26
Note: Unit Rated Capcity @ 30°C Ambient, 32°C Liq., 10°C useful superheat.
TD235
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
STANDARD AIR COOLED CONDENSERS
Horizontal DischargeModel Number
R404aCapacityW @ 15K
Fans Dimensions (mm) Connections (mm)
Number Diameter Voltage Watts Total
Air Flow L/S
L H D Inlet Outlet
SCT168 6659 1 400 230V 150 1310 630 530 205 16 10
SCT189 8717 1 400 230V 150 1230 630 530 205 16 10
SCT1120 11951 1 400 230V 150 1080 630 530 205 16 10
SCS2120 11657 2 350 230V 210 1620 980 430 205 16 10
SCS2150 14406 2 350 230V 210 1560 980 430 205 22 12,5
SCT2170 16758 2 400 230V 300 2960 1200 635 205 22 12,5
SCT2215 20977 2 400 230V 300 2780 1200 635 205 22 12,5
SCT2255 25093 2 400 230V 300 2600 1200 635 205 22 12,5
SCR2275 27500 2 500 230V 780 3730 1400 635 285 28 16
SCR2385 38500 2 500 230V 780 3900 1400 840 285 28 16
SCR2475 47250 2 500 230V 780 3520 1400 940 255 28 16
SCV2720 72030 2 630 400V 2076 6820 2050 840 285 35 22
SCV2850 84481 2 630 400V 2076 6060 2050 940 285 35 22
Vertical DischargeModel Number
R404aCapacitykW @ 15kTD
Fans Dimensions (mm) Connections (mm)
Number Diameter Voltage Watts Amps 3Ph
Air Flow m³/s
L H D Inlet Outlet
SCV2100 100 2 630 400V 3,6 6600 2064 1210 1243 42 35
SCV2115 115 2 630 400V 3,6 6900 2257 1210 1243 42 35
SCV3145 144 3 630 400V 5,4 10400 3064 1210 1243 54 42
SCV3160 162 3 630 400V 5,4 9900 3064 1210 1243 54 42
SCV4195 196 4 630 400V 7,2 12800 3664 1210 1243 65 54
SCV5230 230 5 630 400V 9,0 17500 4564 1210 1243 65 54
SCV4200 200 4 630 400V 7,2 13200 2064 1210 1243*2 42*2 35*2
SCV6280 288 6 630 400V 10,8 20800 3064 1210 1243*2 42*2 35*2
SCV6320 324 6 630 400V 10,8 19800 3064 1210 1243*2 54*2 42*2
SCV8390 392 8 630 400V 14,4 15600 3664 1210 1243*2 62*2 54*2
SCV10460 460 10 630 400V 18,0 35000 4564 1210 1243*2 65*2 54*2
Note: Condenser ratings @ 30°C & 101.325kPa ambient air.Optional: Ziehl-abegg 500 mm & 630 mm 2 speed plate axial fans, EC Variable Speed.
TD236
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
AIR COOLED CONDENSERS - SCT / SCR / SCV
SCT1_ _
SCV 2850
SCV 2720
SCR2475
SCR2385
SCT2_ _
TD237
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
AIR COOLED CONDENSERS - SCV
SCV2100 SCV2125
SCV3_ _ _ SCV4200
SCV5230
TD238
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
EVAPORATOR DATAM
ediu
m T
emp
Real
cold
Stoc
k N
o.N
ew M
odel
Cap
acity
13
4A@
6K
TD
404A
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
umbe
rN
o Fa
nsFa
n D
iam
eter
Fan
pow
er
(Am
p ea
)D
/F E
lem
ent
Num
ber
Def
rost
(k
W)
D/F
Tra
y N
umbe
rD
imen
sion
sC
onne
ctio
nsD
rain
(B
SP)
Wei
ght
(Kg)
LW
HIn
let
Out
let
W46
00H
CT-
251-
2R41
841
00.
122.
5-
125
00.
25n/
a-
n/a
425
450
175
9.5
9.5
12.7
5.5
W46
03H
CT-
251-
4R99
097
00.
133.
0-
125
00.
42n/
a-
n/a
425
450
175
9.5
9.5
12.7
11W
4605
HC
T-25
2_2R
1235
1210
0.33
4.0
-2
250
0.42
n/a
-n/
a75
045
017
59.
59.
512
.716
W46
07H
CT-
252-
4R18
5718
200.
293.
5-
225
00.
42n/
a-
n/a
750
450
175
9.5
12.5
2020
W46
09H
CT-
254-
3R24
8024
300.
33.
5-
425
00.
042
n/a
-n/
a14
0045
017
59.
512
.520
30W
5500
TM14
041
6540
820.
8-
-1
400
0.78
n/a
-n/
a12
2484
535
512
.722
.320
38W
5502
TM27
071
4370
001.
6-
-2
400
0.78
n/a
-n/
a17
0585
036
012
.722
.320
59W
5504
TM31
0010
204
1000
02.
4-
-3
400
0.78
n/a
-n/
a22
0585
036
012
.728
.120
85W
5508
TM31
4014
286
1400
03.
3-
-4
400
0.78
n/a
-n/
a27
0585
036
012
.728
.120
121
W50
00N
M11
414
0013
720.
739.
0R0
930
130
00.
68n/
a-
n/a
770
400
395
12.7
15.9
2017
W50
02N
M11
716
9016
560.
688.
5R0
930
130
00.
68n/
a-
n/a
770
400
395
12.7
15.9
2018
W50
04N
M12
120
9020
480.
648.
0R0
930
130
00.
68n/
a-
n/a
770
400
395
12.7
15.9
2019
W50
06N
M12
423
7023
230.
738.
0R0
930
130
00.
68n/
a-
n/a
975
400
395
12.7
15.9
2021
W50
08N
M12
727
1026
560.
77.
5R0
930
130
00.
68n/
a-
n/a
975
400
395
12.7
15.9
2023
W50
10N
M23
232
0031
361.
459.
0R0
930
230
00.
68n/
a-
n/a
1270
400
395
12.7
15.9
2025
W50
12N
M24
039
5038
711.
368.
5R0
930
230
00.
68n/
a-
n/a
1270
400
395
12.7
15.9
2027
W50
14N
M24
545
2044
301.
288.
0R0
930
230
00.
68n/
a-
n/a
1270
400
395
12.7
22.3
2029
W50
16N
M25
454
5053
412.
058.
0R0
930
330
00.
68n/
a-
n/a
1770
400
395
12.7
22.3
2044
W50
18N
M46
464
0062
722.
919.
0R0
930
430
00.
68n/
a-
n/a
2270
400
395
12.7
22.3
2050
W50
20N
M37
474
0072
521.
937.
5R0
930
330
00.
68n/
a-
n/a
1770
400
395
12.7
22.3
2047
W50
22N
M47
978
9577
372.
738.
0R0
930
430
00.
68n/
a-
n/a
2270
400
395
15.9
28.1
2058
W50
24SM
271
7102
6960
1.76
17.0
R093
52
350
0.58
n/a
-n/
a14
8348
251
012
.722
.320
48W
5026
SM38
685
9984
272.
718
.0R0
935
335
00.
58n/
a-
n/a
2233
482
510
15.9
2920
71W
5028
SM31
0510
653
1044
02.
6417
.0R0
935
335
00.
58n/
a-
n/a
2233
482
510
15.9
3520
75W
5030
SM31
2512
434
1218
52.
5816
.0R0
935
335
00.
58n/
a-
n/a
2233
482
510
15.9
3520
79W
5032
SM41
4014
204
1392
03.
5217
.0R0
935
435
00.
58n/
a-
n/a
2731
482
510
15.9
3520
92W
5034
SM41
6516
574
1624
33.
4416
.0R0
935
435
00.
58n/
a-
n/a
2731
482
510
15.9
3520
98W
5036
SM52
1021
179
2034
04.
2819
.0R0
935
535
00.
58n/
a-
n/a
3223
482
510
15.9
3540
121
W52
00SM
271P
7102
6960
1.76
18.0
R093
52
350
0.58
W72
401.
5n/
a14
8348
251
012
.722
.320
48W
5202
SM38
6P85
9984
272.
720
.0R0
935
335
00.
58W
7242
2.4
n/a
2233
482
510
15.9
2920
71W
5204
SM31
05P
1065
310
440
2.64
19.0
R093
53
350
0.58
W72
422.
4n/
a22
3348
251
015
.935
2075
W52
06SM
3125
P12
434
1218
52.
5818
.0R0
935
335
00.
58W
7242
2.4
n/a
2233
482
510
15.9
3520
79W
5208
SM41
40P
1420
413
920
3.52
17.0
R093
54
350
0.58
W72
443
n/a
2731
482
510
15.9
3540
92W
5210
SM41
65P
1657
416
243
3.44
16.0
R093
54
350
0.58
W72
443
n/a
2731
482
510
15.9
3540
98W
5212
SM52
10P
2117
9-
4.28
19.0
R093
55
350
0.58
W72
463
n/a
3223
482
510
15.9
3540
121
W52
30RM
2140
1400
013
333
4.1
24.0
R095
02
500
1.85
-4.
5n/
a22
1067
080
516
2940
132
W52
32RM
3185
1840
017
524
5.0
24.0
R095
03
500
1.85
-4.
5n/
a22
4068
510
7516
3540
173
W52
34RM
3210
2060
019
619
5.4
24.0
R095
03
500
1.85
-4.
5n/
a27
4068
510
7516
3540
196
W52
36RM
3230
2310
022
000
5.1
24.0
R095
03
500
1.85
-5.
4n/
a27
4068
510
7516
3540
198
W52
38RM
3250
2520
024
000
6.6
24.0
R095
04
500
1.85
-4.
5n/
a27
4068
510
7516
3540
242
W52
40RM
4280
2810
026
762
6.4
24.0
R095
04
500
1.85
-5.
4n/
a27
4068
510
7516
3540
242
W52
42VM
2310
3100
029
524
8.3
25.0
R096
32
630
1.8
-5.
4n/
a22
4077
513
0516
3540
280
W52
44VM
2340
3440
032
762
7.0
26.0
R096
32
630
1.8
-4.
8n/
a22
4077
513
0516
4140
340
W52
46VM
3400
4000
038
095
10.4
26.0
R096
33
630
1.8
-6.
0n/
a32
4077
513
0516
4140
420
W52
48VM
3450
4510
042
952
10.2
26.0
R096
33
630
1.8
-7.
2n/
a32
4077
513
0516
X 2
35 X
240
420
W52
50VM
3480
4830
046
000
10.4
26.0
R096
33
630
1.8
-7.
2n/
a36
0077
513
0516
X 2
35 X
240
430
W52
52VM
4520
5200
049
524
13.0
28.0
R096
34
630
1.8
-8.
0n/
a36
0077
513
0516
X 2
35 X
240
430
W52
54VM
4560
5600
053
333
13.6
28.0
R096
34
630
1.8
-8.
8n/
a38
9077
513
0516
X 2
35 X
240
510
TD239
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
EVAPORATOR DATA
Low
Tem
pRe
alco
ldSt
ock
No.
New
Mod
elC
apac
ity
R404
a@
6K
TD
R22
Air
Flow
(m
³/s)
Air
Thro
w
(m)
Fan
Stoc
k N
umbe
rN
o Fa
nsFa
n D
iam
eter
Fan
pow
er
(Am
p ea
)St
ock
No
Def
rost
(k
W)
D/F
Tra
y N
umbe
rW
atts
Dim
ensi
ons
Con
nect
ions
Dra
in
(BSP
)W
eigh
t (K
g)L
WH
Inle
tO
utle
t
W46
04H
CT-
252-
2RE
830
-0.
133.
0-
225
00.
42-
360
n/a
-75
045
017
59.
59.
520
11
W46
06H
CT-
252-
3RE
1016
-0.
334.
0-
225
00.
42-
360
n/a
-75
045
017
59.
512
.520
16
W46
08H
CT-
253-
3RE
1528
-0.
293.
5-
325
00.
42-
540
n/a
-10
7545
017
59.
512
.520
20
W46
10H
CT-
254-
3RE
2041
--
--
425
00.
42-
720
n/a
-14
0045
017
59.
512
.5
W50
50N
L112
1210
1184
0.73
9.0
R093
01
300
0.68
n/a
1.4
W72
0014
0077
040
039
512
.715
.920
17
W50
52N
L115
1455
1426
0.68
8.5
R093
01
300
0.68
n/a
1.4
W72
0014
0077
040
039
512
.715
.920
18
W50
54N
L118
1800
1763
0.64
8.0
R093
01
300
0.68
n/a
1.4
W72
0014
0077
040
039
512
.715
.920
19
W50
56N
L120
2040
1998
0.73
8.0
R093
01
300
0.68
n/a
1.4
W72
0218
0097
540
039
512
.715
.920
21
W50
58N
L123
2330
2288
0.7
7.5
R093
01
300
0.68
n/a
1.4
W72
0218
0097
540
039
512
.715
.920
23
W50
60N
L228
2760
2706
1.45
9.0
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.715
.920
29
W50
62N
L234
3400
3330
1.36
8.5
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.715
.920
31
W50
64N
L239
3890
3815
1.28
8.0
R093
02
300
0.68
n/a
2.4
W72
0424
0012
7040
039
512
.722
.320
33
W50
66N
L347
4695
4601
2.05
8.0
R093
03
300
0.68
n/a
3.6
W72
0836
0017
7040
039
512
.722
.320
44
W50
68N
L455
5520
5413
2.91
9.0
R093
04
300
0.68
n/a
4.8
W72
1048
0022
7040
039
512
.722
.320
50
W50
70N
L464
6375
6375
1.93
7.5
R093
03
300
0.68
n/a
3.6
W72
0836
0017
7040
039
512
.722
.320
47
W50
72N
L468
6800
6668
2.73
8.0
R093
04
300
0.68
n/a
4.8
W72
1048
0022
7040
039
515
.928
.120
58
W50
74SL
261
6119
5997
1.76
17.0
R093
52
350
0.58
W72
403.
5W
7206
2000
1483
482
510
12.7
22.3
2048
W50
76SL
374
7409
7261
2.7
18.0
R093
53
350
0.58
W72
426.
0W
7210
4800
2233
482
510
15.9
2920
71
W50
78SL
392
9179
8995
2.64
17.0
R093
53
350
0.58
W72
427.
2W
7210
4800
2233
482
510
15.9
3520
75
W50
80SL
3110
1071
310
499
2.58
16.0
R093
53
350
0.58
W72
427.
2W
7210
4800
2233
482
510
15.9
3520
79
W50
82SL
4120
1223
911
994
3.52
17.0
R093
54
350
0.58
W72
447.
7W
7212
3200
2723
482
510
15.9
3540
92
W50
84SL
4145
1428
213
996
3.44
16.0
R093
54
350
0.58
W72
447.
7W
7212
3200
2723
482
510
15.9
3540
98
W50
86SM
521
0P17
836
1747
94.
2819
.0R0
935
535
00.
58W
7246
9.0
W72
2418
0032
2348
251
015
.935
4012
1
W52
60RL
3160
1620
015
600
4.6
24.0
R050
03
500
1.85
W72
409.
0W
7222
3600
2740
670
805
1635
4017
3
W52
62RL
3185
1850
017
800
4.8
24.0
R050
03
500
1.85
W72
4210
.8W
7224
3600
3240
670
805
1635
4019
6
W52
64RL
3200
1970
018
950
4.8
24.0
R050
03
500
1.85
W72
4210
.8W
7222
3600
2740
685
1075
1635
4019
8
W52
66RL
4220
2170
020
865
6.8
25.0
R050
04
500
1.85
W72
4412
.6W
7224
3600
3240
685
1075
1635
4019
8
W52
68RL
4250
2470
023
750
6.4
25.0
R050
04
500
1.85
W72
4414
.4W
7224
3600
3240
685
1075
1635
4024
2
W52
70VL
2280
2800
026
900
7.0
25.0
R063
02
630
1.8
W72
4610
.8W
7220
3600
2240
775
1305
1635
4024
2
W52
72VL
2300
3000
028
850
7.1
25.0
R063
02
630
1.8
W72
4413
.5W
7222
3600
2740
775
1305
1641
4029
0
W52
74VL
3350
3500
033
500
10.4
26.0
R063
03
630
1.8
W72
4614
.4W
7224
3600
3240
775
1305
1641
4034
5
W52
76VL
3400
4000
038
500
10.2
26.0
R063
03
630
1.8
W72
4616
.2W
7224
3600
3240
775
1305
16 X
235
X 2
4034
5
W52
78VL
4450
4500
043
269
12.0
27.0
R063
04
630
1.8
W72
4818
.0W
7226
6400
3600
775
1305
16 X
235
X 2
4043
0
W52
80VL
4500
5000
048
077
13.2
27.0
R063
04
630
1.8
W72
5019
.8W
7288
6400
3890
775
1305
16 X
235
X 2
4043
0
* O
ptio
nal 2
spe
ed Z
iehl
pla
te a
xial
or E
C fa
ns a
vaila
ble
for R
and
V e
vaps
ser
ies
on re
ques
t.
TD240
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
COOLING UNITS
HCT SERIES
NDD DUAL DISCHARGE BLOWER COILS
RDD DUAL DISCHARGE T-FLOW SERIES
RONDO SERIES
TD241
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
COOLING UNITS - N / S SERIES
N_1_ _ N_1_ _ N_2_ _
N_3_ _ N_4_ _
S_2_ _ S_3_ _
S_4_ _ S_5_ _
TD242
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
HCT RANGE UNIT COOLERS
HCT Range Unit Coolers 250 mm Fans - Technical DataModel 251-2R 251-3R 251-4R 252-2R 252-3R 252-4R 253-2R 253-3R 253-4R 254-2R 254-3R 254-4R
Fin Spacing 6F (4.2 mm)
Nominal Capacity R22
kW @ ITD = 6K and Te = -5°C
0.41 0.55 0.63 0.97 1.21 1.33 1.49 1.82 2.00 1.99 2.43 2.67
Coil surface area m² 1.0 1.5 2.0 2.0 3.0 4.0 3.0 4.5 6.0 4.0 6.0 8.0
Air flow - frost free m³/s 0.14 0.12 0.11 0.28 0.24 0.22 0.43 0.36 0.32 0.57 0.49 0.43
Face velocity m/s 2.91 2.49 2.22 2.91 2.49 2.22 2.91 2.49 2.22 2.91 2.49 2.22
Mass Kg 5.2 5.5 5.7 7.8 8.4 8.9 10.9 11.7 12.4 14.0 15.0 16.0
General Data
Tube internal volume litre 0.35 0.53 0.71 0.62 0.94 1.25 0.89 1.34 1.79 1.16 1.75 2.33
Air throw m 10 9 8 10 9 8 10 9 8 10 9 8
Liquid connection inch 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4” 1/4”
Suction connection inch 3/8” 3/8” 3/8” 3/8” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1/2”
Elect. defrost 230V kW 0.12 0.18 0.24 0.24 0.36 0.48 0.36 0.54 0.72 0.48 0.72 0.96
Physical Data
• Models: HCT 251 2R/3R/4R & 252 2R are suitable for internally equalized expansion valves
• Models: 252 3R and above are suitable for externally equalized expansion valves
• Drain: 3/4” BSPM Fitting
• Fan: 250 mm diameter, 230/ 1/ 50Hz, 42 W x 0.42 A each
TD243
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
RONDO RANGE UNIT COOLERS
Rondo Range Unit Coolers 250 mm & 300 mm Fans - Technical DataModel 140-A 240-A 340-A 440-A 400-A 500-A 700-A 900-A 1100-A 1300-A
Fin Spacing 6F (4.2 mm)
Nominal Capacity R22
kW @ ITD = 6K and Te = -5°C
0.63 0.80 0.95 1.08 1.19 1.66 2.06 3.38 4.04 4.64
Coil surface area m² 1.98 2.97 3.71 4.45 4.15 6.23 8.3 10.22 12.77 17.03
Air flow - frost free m³/s 0.21 0.19 0.21 0.22 0.29 0.37 0.43 0.92 1.05 0.94
Face velocity m/s 2.22 1.96 1.76 1.57 2.25 1.92 1.65 2.88 2.64 2.36
Mass Kg 4.00 4.50 5.00 5.50 7.20 8.30 9.40 14.00 15.40 17.40
General Data
Tube internal volume litre 0.56 0.84 1.05 1.26 1.15 1.72 2.3 2.80 3.5 4.66
Fans no x dia 1 x 250 1 x 250 1 x 250 1 x 250 2 x 250 2 x 250 2 x 250 2 x 300 2 x 300 2 x 300
Liquid connection inch 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction connection inch 3/8” 3/8” 3/8” 3/8” 1/2” 1/2” 5/8” 5/8” 3/4” 3/4”
Fan WiringDiameter mm Voltage V Frequency Hz RPM Power W Amperage A
Square shaded-pole motor (standard)
250 230 50 1300 16/60 0.42
300 230 50 1300 34/110 0.75
External rotor motor (option)
300 230 50 1400 68 0.3
TD244
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
HDD RANGE DUAL DISCHARGE COOLERS
HDD Range Dual Discharge Coolers 250 mm Fans - Technical DataModel 251-A-2R 251-A-3R 251-A-4R 252-A-2R 252-A-3R 252-A-4R
Fin Spacing 6F (4.2 mm)
Nominal Capacity R22
kW @ ITD = 6K and Te = -5°C
0.78 0.95 1.03 1.67 2.03 2.18
Coil surface area m² 1.76 2.63 3.52 3.51 5.27 7.02
Air flow - frost free m³/s 0.19 0.16 0.15 0.39 0.33 0.29
Face velocity m/s 2.22 1.89 1.69 2.22 1.89 1.69
Mass Kg 5.70 6.20 6.80 9.50 10.50 11.50
General Data
Tube internal volume litre 0.53 0.79 1.05 1.06 1.58 2.1
Air throw m 2.7 2.3 2.1 2.7 2.3 2.1
Fans no x dia 1 x 250 1 x 250 1 x 250 2 x 250 2 x 250 2 x 250
Liquid connection inch 3/8” 3/8” 3/8” 3/8” 3/8” 3/8”
Suction connection inch 3/8” 3/8” 3/8” 1/2” 5/8” 5/8”
Elect. defrost 230V kW 0.45 0.45 0.45 0.90 0.90 0.90
Physical Data
• Models: 201 2R and above are suitable for externally equalized expansion valves
• Drain: 1/2” Copper tube
• Fan: 250 mm diameter, 230/ 1/ 50Hz, 16 W x 0.42 A each
TD245
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
HSR RANGE UNIT COOLERS
HSR Range Unit Coolers 350 mm Fans - Technical DataModel 351-4R 351-6R 352-4R 352-6R 353-4R 353-6R 354-4R 354-6R
Fin Spacing 6F (4.2 mm)
Nominal Capacity R22
kW @ ITD = 6K and Te = -5°C
3.24 3.82 6.54 7.70 9.83 11.58 13.14 15.44
Coil surface area m² 16 24 32 48 48 72 64 97
Air flow - frost free m³/s 0.71 0.65 1.42 1.30 2.13 1.95 2.84 2.60
Face velocity m/s 2.67 2.44 2.67 2.44 2.67 2.44 2.67 2.44
Mass Kg 23 27 38 44 51 61 65 78
Fin Spacing 4F (6.35 mm)
Nominal Capacity R22
kW @ ITD = 6K and Te = -5°C
2.66 3.33 5.33 6.70 8.04 10.07 10.73 13.45
Coil surface area m² 11 17 22 33 33 50 44 67
Air flow - frost free m³/s 0.75 0.70 1.50 1.40 2.25 2.10 3.00 2.80
Face velocity m/s 2.79 2.61 2.79 2.61 2.79 2.61 2.79 2.61
Mass Kg 23 26 37 43 49 58 63 75
General Data
Tube internal volume litre 3.44 5.16 6.26 9.38 9.07 13.61 11.59 17.83
Air throw m 14 14 15 15 16 16 17 17
Liquid connection inch 1/2” 1/2” 1/2” 1/2” 5/8” 5/8” 5/8” 5/8”
Suction connection inch 7/8” 7/8” 1 1/8” 1 1/8” 1 1/8” 1 3/8” 1 3/8” 1 3/8”
Elect. defrost 230V kW 2.0 2.5 4.0 5.0 6.0 7.5 8.0 10.0
Physical Data
• Models: 351 4R and above are suitable for externally equalized expansion valves
• Drain: 3/4” BSPM Fitting
• Fan: 350mm diameter, 230 /1/50 Hz, 130 W x 0.58 A each
Dimensions (mm) A 350 350 375 375 400 400 500 500
TD246
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
SMALL COOLROOM CAPACITIES
Small Coolroom Capacities
• Typical Coolroom
• Duties for Small Storage Only Rooms
• 30°C ambient
• Coolrooms 100 mm polystyrene walls and ceiling
• Freezers 150 mm polystyrene wals, floor, ceiling
• Internal hieght = 2.4 m
• For other specific applications contact
• Realcold Technical Department +64 (0)9 526 5700
Small Coolroom Capacities - InformationRoom Dimension Medium Temp +2°C Low Temp -18°C
Length (m) Width (m) Volume (m³) Average (W) Heavy (W) Average (W) Heavy (W)
1.8 1.2 3.8 900 1170 1400 1820
1.8 1.8 6.1 1100 1430 1600 2080
2.4 1.8 8.4 1300 1690 1800 2340
2.4 2.4 11.6 1500 1950 2000 2600
3.0 2.4 14.8 1700 2210 2200 2860
3.0 3.0 18.8 2000 2600 2400 3120
3.6 2.4 18.0 2000 2600 2400 3120
3.6 3.0 22.8 2300 2990 2600 3380
3.6 3.6 27.7 2700 3510 2800 3640
4.2 2.4 21.1 2200 2860 2500 3250
4.2 3.0 26.9 2500 3250 2800 3640
4.2 3.6 32.6 3000 3900 3200 4160
4.2 4.2 38.4 3300 4290 3500 4550
4.8 3.6 37.5 3300 4290 3500 4550
4.8 4.2 44.2 4000 5200 4200 5460
4.8 4.8 50.8 4500 5850 4800 6240
6.0 3.6 47.3 4300 5590 4500 5850
6.0 4.2 55.7 4700 6110 5000 6500
6.0 4.8 64.0 5000 6500 5500 7150
6.0 6.0 80.7 5500 7150 6000 7800
TD247
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
REFRIGERATION TERMINOLOGY
Refrigeration Terminology
Temperature
Indicates level of heat energy
1. Centigrade Scale ºC (Celsius)
Absolute Temperature ºK (Kelvin) = ºC + 273º
2. Fahrenheit Scale ºF. Absolute Temperature º (Rankin) = ºF + 460
3. Conversion: ºC = 5/9 x (ºF - 32) ºF = (9/5 x ºC) + 32
Measurement
A British Thermal Unit (BTU) is the heat required to raise or lower the temperature of 1 lb of water 1ºF. 4.19 Kilojoule is the heat required to raise or lower 1 Kg of water 1 K
State of Matter
Solid, liquid and gas
Change of State
The change from one state of matter to another by the addition or the removal of heat at constant temperature.
Sensible Heat
Heat added to or subtracted from a substance without a change of state (only a change in temperature).
Specific Heat
The amount of sensible heat required to raise the temperature of 1 lb (1kg) of a substance 1ºF (1K) or the ratio of the heat capacity of the sub-stance to that of water.
Latent Heat
Quantity of heat added to or removed from a unit weight of a substance during change of state at constant temperature.
(BTU/lb) (kj/kg)
1. Latent Heat of Fusion: Melting of a solid or freezing of a liquid.
2. Latent Heat of Evaporation: Change from a liquid to a gas.
3. Latent Heat of Condensation: Change from a gas to a liquid.
Total Heat (Enthalpy) Heat Capacity
The sum total of sensible and latent heat quantities. BTU/lb (kj/kg), usu-ally referenced to -40º at which point the Total Heat (Enthalpy) is taken as 0 BTU/lb with negative values below -40º. When all heat has been extracted from a substance, it is said to be at Absolute Zero 0ºR (Rankin) or correspondingly 0ºK (Kelvin).
Note: Enthalpy referenced to 0ºF for air.
Pressure
Expressed in Pounds per Square Inch, Gauge; or Absolute Pressure (psig or psia).
1. Atmospheric Pressure: At sea level is 14.7 lbs/sq. inch absolute (deduct approx. 0.5 lbs/sq. inch or 1 inch of mercury for every 1,000 feet increase in elevation above sea level).
2. Gauge Pressure: Is equal to Absolute Pressure less Atmospher-ic Pressure. Thus at 4,000 feet elevation gauge pressure (psig) will be 4 x 0.5 or 2 lbs/sq. inch (psi) higher than at sea level for the same condition.
3. Vacuum: Pressures below atmospheric pressure are measured in inches of mercury (vacuum) (two inches of mercury can be equal to one lb/sq. inch). A perfect vacuum (0 psia) being equal to 29.92 inches of mercury (“Hg) or 760mm, at sea level. Meas-urements are sometimes expressed in microns (1,000,000) mi-crons in a metre).
4. Vapour Pressure: Equilibrium Pressure between a liquid and its saturated vapour. As long as vapour and liquid are both pre-sent, there will be only one vapour pressure for each level of temperature.
5. Gas Pressure: In the absence of liquid, the pressure of a gas is proportional to Absolute gas temperature and to gas density (perfect gas laws).
Saturated Vapour and Liquid
When gas and liquid exist in equilibrium, there will be only one vapour pressure for each level of temperature.
1. Subcooled Liquid: If additional heat is removed from saturated liquid in the absence of vapour, its temperature is reduced at constant pressure and it becomes subcooled.
2. Superheated Gas: If additional heat is added to saturated va-pour in the absence of liquid, it becomes superheated vapour or gas.
Conversion: 1 Ton of Refrigeration = 12,000 BTU/Hr
= 3.517 kW
= 3517 Watts
1 Watt = 3.412 BTU/Hr
1 psi = 6.895 kPa
Refrigeration Cycle Calculations*
1. Refrigerating Effect: (BTU/lb)= Enthalpy of vapour leaving the evaporator minus the enthalpy of liquid ahead of throttling de-vice.
2. Quality: Fraction of liquid flashed at the throttling device to cool the balance of the liquid to evaporator temperature = Enthalpy of liquid ahead of throttling device minus enthalpy of saturated liquid at evaporator temperature divided by the latent heat at evaporator temperature.
3. Refrigerant Flow Rate: (Lbs/min/ton) = 200 BTU/min divided by the refrigerating effect.
4. CFM Gas to Compressor: Flow rate (Lbs/min/ton) times specific volume (Cu ft/lb) of gas entering the compressor - CFM Gas/Ton.
5. Compression Ratio: Discharge pressure psia divided by suction pressure psia.
6. Reciprocating Compressor Displacement in CFM
= RPM x No. of cylinders x π D² x S x 1 4 1728
where: D = Cylinder Bore in inches and S = Piston Stroke in inches.
7. Volumetric Efficiency: of a compressor is the ratio of the volume of suction gas actually pumped to the displacement or swept volume of the compressor. The biggest factors affecting volu-metric efficiency are: Compression ratio and cylinder clearance volume for reciprocating compressors; Compression ratio and differential pressure for rotary screw compressors.
8. Heat of Compression (BTU/lb): Enthalpy of the discharge gas, leaving the compressor minus the enthalpy of the suction gas entering the compressors.
9. Heat Rejection to the Condenser:
a) Enthalpy of discharge gas leaving the compressor less the enthalpy of the liquid leaving the condenser in BTU/lb times the Refrigerant Flow Rate = Heat of rejection in (BTU/min/ton).
b) Tons of refrigeration times 12,000 BTU/Hr/Ton plus the compressor brake HP times 2545 BTU/Hr/Hp (or her-metic motor kilowatts times 3415 BTU/Hr/kW) = Heat of Rejection in BTU/Hr.
* Refer to Refrigerant Tables or Mollier Charts for thermodynamic properties of the refrigerant.
TD248
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
TECHNICAL TIPS
Technical Tips
Silver Brazing - Inert Gas Prevents Copper Oxide Formation
The purpose of this article on silver brazing is to enlarge on one serious after-effect if proper procedures are not used during sil-ver brazing operations.
The use of high melting point alloys has increased considerably in recent years particularly in supermarkets, processing plants, air conditioning or wherever a large number of joints are used. The inherent mechanical strength of the joint and the reduction of leak possibilities have made this a desirable type of joint. In addition, code requirements in some areas have forced the used of these alloys.
In order for brazing alloys to melt and flow properly, red beat, 620 to 790ºC is required. Copper will react with the oxygen in air at these temperatures to form a scale of copper oxide in air at these temperatures to form a scale of copper oxide on the in-ner walls of tubing, pipe and fittings. The scale is broken off into flakes by the turbulence of flowing liquid refrigerant. The flakes quickly break up into a fine powder which plugs driers, strainers and capillary tubes.
Copper oxide is so finely divided that a filter bed of other mate-rials is usually required in driers before the filtration system in the drier can remove it, thus accounting for the approximately 48 hours needed to remove this material. This assumes that the original drier does not plug. If it does, longer will be required.
Driers are sometimes returned as defective because they have shown an undesirable pressure drop on a new system. In con-junction with other dirt, a substantial accumulation of copper oxide is often the explanation. Chemical analysis readily confirm the condition. The drier is not defective, on the contrary, it has done exactly what it was designed to do - take out the ‘dirt’.
If the air in the line being brazed is replaced with an inert gas such as dry nitrogen, the formation of copper oxide can be elimi-nated. The line should be purged thoroughly and a slow steady flow of nitrogen maintained by means of a pressure reducing valve.
High pressure gas (nitrogen) should never be connected directly to a system but must be metered through a pressure reducing valve for the protection of the user. Too high a rate of flow is un-desirable because of the cooling effect of the gas.
The inert gas method will keep the inside of the copper lines and fittings clean and bright. When it is not completely successful, the trouble is usually attributed to applying heat before all of the air has been displaced.
On large copper pipe, the end of the tubing should be covered with some type of elastic material such as a rubber balloon and a small slit made in the rubber to provide an escape valve. In this manner, the line can be kept full of nitrogen without use of excessive quantities.
The inert gas method, wherever practical, is recommended for repair work. The nitrogen clears the line of refrigerant vapour preventing acid formation due to refrigerant breakdown as well as preventing copper oxide formation.
Many service engineers find it impractical to transport heavy nitrogen cylinders in and out of buildings and have solved the problem by permanently mounting the cylinder on their service truck. The cylinder is equipped with a pressure reducing valve and flexible lines long enough to reach most of their jobs. Purge hose or a similar type of material is satisfactory for the flexible line. The line pressure is held to an absolute minimum with the gas flow just high enough to maintain the required slow, steady rate of flow.
Note:
Cadmium bearing brazing alloys present a dangerous toxic hazard. Extreme care in providing adequate ventilation during brazing operations is an absolute necessity. Inhalation of cad-mium fumes may produce extreme illness or could be fatal.
Trouble Shooting Tips - a list of Do’s and Dont’s for Commercial RefrigerationDo Don´t
• Check suction gas superheat at the compressor. High superheats cause high discharge temperatures and shorten compressor life.
• Check expansion valve superheat using the temperature pressure method (refer to Page TD249). Set to equipment manufacturer’s specification.
• Replace the filter-driers or drier cores when opening the system for service.
• Maintain test instruments in workable calibrated condition.
• Use an accurate liquid line moisture indicator to ensure system dryness.
• Read and observe installation and safety instructions included with a product.
• Familiarise yourself with the operation of a control before attempting to make adjustments or repairs.
• Remember that a thermostatic expansion valve is not a temperature or pressure control.
• Select solenoid valves by line size or port size. Select based on valve capacity.
• Rely on sight or touch for temperature measurements. Use an accurate thermometer.
• Be a ‘parts changer’. Analyse the problem and determine the cause or failure before making adjustments or repairs.
• Attempt to re-use driers or direr blocks once they have been removed from the system.
• Energise a solenoid coil with it removed from a valve. It will burn out in a matter of minutes.
TD249
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
EVAPORATION SUPERHEAT
Evaporation Superheat
Thermostatic Expansion Valve - Superheat
A vapour is superheated whenever its temperature is higher than the saturation temperature corresponding to its pressure. The amount of the superheat equals the amount of temperature increase above the saturation temperature at the existing pres-sure.
For example, a refrigeration evaporator is operating with Refrig-erant 22 at 465 kPa suction pressure. The Refrigerant 22 satura-tion temperature at 465 kPa is 4ºC. As long as any liquid exists at this pressure, the refrigerant temperature will remain 4ºC as it evaporates or boils off in the evaporator.
As the refrigerant moves along in the coil, the liquid boils off into a vapour, causing the amount of liquid present to decrease. All of the liquid is finally evaporated at point B because it has absorbed sufficient heat from the surrounding atmosphere to change the refrigerant liquid to a vapour. The refrigerant gas continues along the coil and remains at the same pressure (465 kPa) however, its temperature increases due to continued ab-sorption of heat from the surrounding atmosphere. When the refrigerant gas reaches the end of the evaporator (Point C), its temperature is 10ºC. This refrigerant gas is now superheated and the amount of superheat is 6ºC or 6ºK (10º - 4º). The de-gree to which the refrigerant gas is superheated depends on the amount of the refrigerant being fed to the evaporator by the T.X. valve and the heat load to which the evaporator is exposed.
Adjustment of Superheat
The function of a T.X. valve is to control the superheat of the suc-tion gas leaving the evaporator in accordance with the valve set-ting. A T.X. valve which is performing this function within reason-able limits can be said to be operating in a satisfactory manner.
Good superheat control is the criterion of T.X. valve performance. It is important that this function be measured as accurately as possible, or in the absence of accuracy, to be aware of the mag-nitude and direction of whatever error is present.
Superheat has been previously defined as the temperature in-crease of the refrigerant gas above the saturation temperature at the existing pressure. Based on this definition, the pressure and temperature of the refrigerant suction gas passing the T.X. valve remote bulb are required for an accurate determination of superheat.
Thus, when measuring superheat, the recommended prac-tice is to install a calibrated pressure gauge connection at the evaporator outlet. In the absence of a gauge connection, a tee installed in the T.X. valve external equalizer line can be sued just as effectively.
A refrigeration type pocket thermometer with appropriate bulb clamp may be used, or more effective is the use of a service type potentiometer (electric thermometer) with thermocouples (leads and probes).
The temperature element from your Temperature Meter should be clamped to the suction line at the point of remote bulb loca-tion and must be insulated against the ambient. Temperature elements of this type, as well as thermometers, will give an aver-age reading of suction line and ambient if not insulated. Assum-ing an accurate gauge and Temperature Meter, this method will provide sufficiently accurate superheat readings for all practical purposes.
On installations where a gauge connection is not available and the valve is internally equalized, there are two alternate methods possible. Both of these methods are approximations only and their use is definitely not recommended.
The first of these is the two temperature method which utilizes the difference in temperature between the evaporator inlet and outlet in temperature between the evaporator inlet and outlet as the superheat. This method is in error by the temperature equivalent of the pressure drop between the two points of tem-perature.
Where the pressure drop between the evaporator inlet and out-let is 7kPa or less, the two temperature method will yield fairly accurate results. However, evaporator pressure drop is usually an unknown and will vary with the load. For this reason, the two temperature methods cannot be relied on for absolute super-heat readings. It should be noted that the error in the two tem-perature method is negative and always indicates a superheat lower than the actual figure.
The other method commonly used to check superheat involves taking the temperature at the evaporator outlet and utilizing the compressor suction pressure as the evaporator saturation pres-sure. The error here is obviously due to the pressure drop in the suction line between the evaporator outlet and the compressor suction gauge.
On self-contained equipment, the pressure drop and resulting error are usually small. However, on large built-up systems or systems with long runs of suction line, considerable discrepan-cies will usually result.
Since estimates of suction line pressure drop are usually not accurate enough to give a true picture of the superheat, this method cannot be relied on for absolute values. It should be noted that the error in this instance will always be positive and the superheat resulting will be higher than the actual value.
Restating, the only method of checking superheat that will yield an absolute value involves a pressure and temperature reading at the evaporator outlet.
Other methods employed will yield a fictitious superheat that can prove misleading when used to analyse T.X. valve performance. By realizing the limitations of these approximate methods and the direction of the error, it is often possible to determine that the cause of a trouble call is due to the use of improper methods of instrumentation rather than any malfunction of the valve.
TD250
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
A GUIDE TO CALCULATING NOISE LEVELS
A Guide to Calculating Noise Levels
Step 1 - SWL of Unit
Enter the Sound Power Level (SWL) of the proposed equipment at the top of the table.
Step 2 - Distance Factor
Determine the shortest distance between the location of the proposed unit and the receiver position (e.g. neighbour). For Simplicity the distance between the unit and the boundary may be acceptable. Circle the corresponding Distance Factor in Column 1.
Step 3 - Barrier Effect
Determine the type of barrier - If any between the proposed unit and the receiver position. Check the section on “Barriers” to determine the situation you have. Remember that an “Ineffective Barrier: is one where there is no barrier or the barrier or fence has holes in it which allows the noise to pass through it (e.g. picket fences, missing planks, decorative openings etc.). Circle the corresponding Barrier Factor in Column 2.
Step 4 - Reflection Factor
Determine the number of reflective surfaces that are within 3 metres of the proposed unit, such as walls and large eaves (do not include the ground). Circle the corresponding Reflection Factor in Column 3.
Step 5 - Resultant Noise Level
Determine the estimated Resultant Noise Level by:
Noise Level = SWL of Proposed Unit - Distance Factor - Barrier Effect - Reflection Factor
Sound Power Level (SWL) of Proposed Unit — dBA
Column 1
Shortest straight line distance from Unit to Receiver position (m)
Distance Factor
1 8
2 14
3 17
4 20
5 22
6 23
7 25
8 25
10 28
Column 3
Reflection Reflection Factor
No reflecting surfaces within 3m
0
One refecting surface within 3m (one wall)
3
Two refecting surfaces with 3m (two walls)
5
Three reflecting surfaces within 3m (two walls and large eaves)
6
Column 2
Barrier Barrier Effect
Ineffective Barrier 0
Effective Barrier
Line of sight to unit not blocked
0
Blocks line of sight to unit
5
High barrier blocks line of sight of unit by more than 1m
8
TD251
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
METRIC CONVERSION CHART
Metric Conversion Chart
Remarks A B C
Multiply By To Obtain
Area: Symbol m²
The SI unit of AREA is the SQUARE METRE
square inches square feet square yards acre hectare (ha)
645.16 0.929 0.836 4047 10,000
mm² m² m² m² m²
Length: Symbol m
The SI unit of LENGTH is the METRE
inches feet yards mile mile"
25.4 0.3048 0.9144 1609 1.609
millimetres (mm) metres (m) metres (m) metres (m) Kilometres (km)
Mass: Symbol kg
The SI unit of MASS is the KILOGRAM
ounce pound ton (2240 lb) short ton (2000 lb) ton (2240 lb) pounds per foot (lb/ft)
28.35 0.436 1016.05 907.2 1.016 1.488
grams (g) kilograms (kg) kg kg tonne (t) kg/m
Volume: Capacity: Symbol m³
The SI unit of VOLUME is the CUBIC METRE
Dry: cubic inch (in³) cubic foot (ft³) cubic yard (yd³) litre (L) litre (L) gallons (lmp)
16,387 0.02832 0.7646 1,000,000 0.001 0.004546
mm³ m³ m³ mm³ m³ m³
Imperial Liquid: fluid ounce pint (20fl.oz) quart (2 pints) gallon (lmp) gallon (US) litre (water 4ºC) Imp.gallons (water 20ºC)
28.41 568.3 1.137 4.546 3.785 1.000 4.536
millilitre (ml) millilitre (ml) litre (L) litre (L) litre (L) kilogram (kg) kilogram (kg)
Volume: Rate Of Flow Symbol m³/s
The SI unit of VOLUME RATE OF FLOW is the CUBIC METRE PER SECOND
Imp. gal. per min (gal/min) Imp. gal. per min Imp. gal. per min
0.000758 0.272765 0.758
m³/s m³/hr litre per second (L/s)
Pressure: Symbol Pa
The SI unit of PRESSURE or stress is the NEWTON PER SQUARE METRE which has been given the name PASCAL
1N/m² = 1Pa = 0.000145lbf/in²
A pascal is the pressure or stress which arises when a force of one newton is applied uniformly over an area of one square metre
lbf/in² kip/in² (1000 psi) lbf/ft² kgf/cm² bar
6.895 6.895 47.88 98.07 100
kPa Mpa Pa kPa kPa
Vertical column (head) of water. (H²O at 20ºC) metres of water feet of water torr (vacuum 1mm Hg. (mercury) 1mm Hg. (mercury) atmosphere (atm) microns
9.79 2.984 0.133 0.133 3.386 101.325 0.133
kPa kPa kPa kPa kPa kPa Pa
Density: Symbol kg/m³
The SI unit of DENSITY is the KILOGRAM PER CUBIC METRE
lb/in³ lb/ft³ lb/yd³
27.68 16.02 0.5933
t/m³ kg/m³ kg/m³
Remarks A B C
Multiply By To Obtain
Velocity: Symbol m/s
The SI unit of VELOCITY is the METRE PER SECOND
ft. per sec (ft/s) ft. per min (ft/min) miles per hour miles per hour
0.3048 0.00508 0.4470 1.609
m/s m/s m/s km/h
Power: Symbol W
The SI unit of POWER is the WATT
Btu per hour (Btu/hr) Horsepower (hp) ton of refrigeration
0.2931 0.7457 3.517
W kW kW
Energy: Symbol J
The SI unit of ENERGY is the JOULE
1J = 1 N.m
A joule is the energy expended or the work done when a force of one newton moves the point of application a distance of one metre in the direction of that force
Electrical Energy kilowatt hour (kW.h)
3.6
MJ
Heat Energy British thermal unit (Btu) Btu/ft³
1.055 37.26
KJ KJ/m³
Mechanical Energy foot poundal (ft.pdl) inch pound-force (in.lbf) foot pound-force (ft.lbf) foot ton force (ft.tonf) metre kilogram force (m.kgf)
0.4214 0.1130 1.356 3.037 9.807
J J00 J KJ J
Force: Symbol N (Newton)
The SI unit of FORCE (kg.m/s²) has been given the special name - NEWTON.
The newton is the force which when applied to a body having a mass of one kilogram, causes an acceleration of one metre per second in the direction of application of the force
Pountal (pdl) Pound-force (lbf) ton-force (tonf) *kilogram-force (kgf)
0.1383 4.448 9.964 9.807
N N kN N
*also known as kilopond (kp)
Force Per Unit Length:
The SI unit is NEWTON/per metre Symbol N/m
pounds-force per inch (Ibf/in) pounds-force per foot (lbf/ft) ton-force per foot (ton/ft)
175.1 14.59 32.69
N/m N/m kN/m
Torque: Symbol N.m (Moment of force
The SI unit of TORQUE is the NEWTON METRE
The NEWTON METRE is the work done when a force of one newton moves the point of application a distance of one metre in the direction of that force.
1N.m = 1J
Poundal-foot (pdl.ft) pound-force inch (lbf.inch) (lbf.inch) pound-force feet (lbf.ft) (lbt.ft) ton-force feet (tonf.ft) Kilogram-force (kgf.m) (kgf.cm)
0.04214 0.113 1.152 1.356 13.83 3.037 9.807 0.09807
N.m N.m kgf.cm N/m kgf.cm kN.m N.m N.m
TD252
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
GENERAL RULES & FIRST AID
General RulesGeneral Rules for handling Fluorocarbon Refrigerants
Safety Equipment
Goggles or face shields, gloves and safety footwear must be worn when filling cylinders, coupling up storage vessels and/or handling bulk fills so as to prevent eye damage or burns should a coupling give way or a line burst.
Keep Away from Fire
No part of any cylinder should ever be subjected to direct flame, steam or temperatures exceeding 50’C. If necessary to warm cylinder to promote more rapid discharge, extreme caution should be taken - an easy and safe way is to place bottom part of cylinder in a container of warm or hot water not over 50’C.
Store Cylinders Upright
Store cylinders in a cool, dry place, away from direct sources of heat. A well ventilated area will ensure that no build up of gas can occur should a cylinder leak or relief valve unseat.
Behaviour in Presence of Open Flame
All commercially available fluorinated hydrocarbon refrigerants are non-inflammable and non-explosive - an extremely impor-tant safety feature. These refrigerants will decompose however, if subjected to sufficiently high temperatures. Over 540’C is re-quired for decomposition, and since the average flame tem-perature is higher, decomposition may occur. It should be noted that only the refrigerant vapour that actually passes through the flame will be affected. When fluorinated hydrocarbon refriger-ants are decomposed by high temperature, they form hydrogen chloride, hydrogen fluoride and small quantities of other gases which may cause ill effects if inhaled in sufficient quantities. Gen-erally, the pungent odour of these products give ample warning of their presence.
Do Not Force Connections
Cylinder connections should fit easily and snugly. Never force them. Use correct tools. Stripped threads can cause leaks and possible loss of refrigerant.
Handle Cylinders Carefully
Cylinders should not be used for ‘rollers’ or supports. Cuts and abrasions may result. Care in handling cylinders will prolong their life.
Read Labels
Because colour of cylinders cannot be relied upon for positive identification, labels should always be read carefully. Colour blindness might interfere with proper identification. If still in doubt, other methods of identification are available from the manufacturer/supplier.
Visual Examination
Each time a cylinder is returned or delivered for re-charging, it should be carefully examined for evidence of corrosion, cuts, dents, bulges, condition of threads, valves, etc, to ensure suit-ability for further service. State Codes also provide for examina-tion and testing of cylinders to ensure their continued use.
Ventilation
Since many materials such as soldering flux, oil, dirt and all re-frigerants decompose at the flame temperatures used in solder-ing, the area in which repair is carried out should be properly ventilated to remove the products of decomposition and com-bustion of all materials. An adequately ventilated work area is good practice at any time, but especially when an open flame of a leak detector or welding torch is to be used in the presence of ‘fluorocarbon’ refrigerants.
Never Transfer
Refrigerant cylinders are labelled and identified for a particular refrigerant. Never put a different refrigerant into a cylinder la-belled for another refrigerant.
Check Pressure
The pressure within the cylinder must be greater than in the sys-tem to cause the refrigerant to flow into the system. Pressure should be checked before charging.
Health Effects and First Aid
Swallowed
This product is a vapour at ambient temperature and pressure: therefore any liquid present in an open vessel will be boiling at a very low temperature and accidental contact with mouth or throat tissue would generate severe frost burning, but it is obvi-ously extremely unlikely.
Eye
Frost burning of eye tissue would occur in the event of accidental contact. In cases of frost bite: Rinse with plenty of water and seek medical advice.
Inhaled
The vapour of this product is denser than air and may reduce the available oxygen. The symptoms likely to be experienced upon inhalation of the vapour include: narcososi, anaesthesia, respiratory depression, unconsciousness and possible asphyxi-ation. In addition, inhalation may lead to cardiac arrythmias in susceptible individuals.
Move to fresh air, rest, half upright position, loosen clothing. Give oxygen or artificial respiration if there is any difficulty in breath-ing. Apply external cardiac massage in case of cardiac arrest.
Skin
Contact with skin of boiling liquid may cause frost bite. In cases of frost bite : DO NOT remove clothes. Rinse skin with plenty of water. Treat frost bite as for thermal burns. Seek medical advice.
Advice to Doctor
Ensure first aid procedures have been carried out. Treat sympto-matically. Avoid the use of adrenaline.
TD253
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
PRESSURE TEMPERATURE CHART
Pressure Temperature Chart R2
2R5
02R7
17R7
44Te
mp
°CkP
Ag
psig
kPA
gps
igkP
Ag
psig
kPA
gps
igTe
mp
°F-5
0-3
5.5
10.5
*-1
9-2
.8-5
9.2
17.5
*58
284
.5-5
8-4
8-2
8.6
8.4*
-10
-1.5
-54.
316
*63
992
.7-5
4.4
-46
-21.1
6.2*
-1-0
.1-4
8.9
14.4
*70
010
2-5
0.8
-44
-13
3.8*
81.2
-42.
712
.6*
764
111
-47.
2-4
2-4
.21.2
* 19
2.8
-35.
910
.6*
833
121
-43.
6-4
00.
010.
530
4.4
-28.
38.
4*90
513
1-4
0-3
810
1.542
6.1
-20.
36*
981
142
-36.
4-3
622
3.5
547.
8-1
1.63.
4*10
6115
4-3
2.8
-34
324.
668
9.9
-2.1
0.6
*11
4516
6-2
9.2
-32
507.
282
11.9
8.3
112
3417
9-2
5.6
-30
639.
198
14.2
19.4
2.6
1328
193
-22
-28
8012
114
16.5
31.5
4.4
1426
207
-18.
4-2
691
1313
219
.244
.66.
715
9223
1-1
4.8
-24
108
1615
021
.858
.68.
716
3823
7-1
1.2-2
212
618
170
24.7
73.8
1117
5125
4-7
.6-2
014
521
191
27.7
90.1
1318
7027
1-4
-18
164
2421
330
.910
815
1994
289
-0.4
-16
195
2723
634
.312
618
2124
308
3.2
-14
207
3026
137
.914
621
2259
328
6.8
-12
231
3328
741
.716
824
2401
348
10.4
-10
254
3731
445
.619
128
2549
370
14-8
284
4134
349
.821
531
2703
392
17.6
-631
045
373
54.1
242
3528
6341
521
.2-4
334
4840
558
.826
939
3030
439
24.8
-236
152
438
63.6
299
4332
0446
528
.40
398
5847
368
.732
848
3285
476
322
430
6251
074
382
5337
6954
735
.64
465
6754
879
.539
758
4183
607
39.2
650
473
588
85.3
433
6346
3067
142
.88
542
7963
091
.447
369
5111
741
46.4
1058
485
673
97.7
513
7456
2981
650
1262
290
718
104.
255
581
5903
856
53.6
1466
897
766
111.2
605
8861
8889
757
.216
716
104
815
118.
365
495
6484
940
60.8
1876
911
286
612
5.7
704
102
6792
985
64.4
2081
411
892
013
3.5
755
110
7114
1032
6822
866
126
975
141.5
811
118
71.6
2491
713
310
3314
9.9
868
126
75.2
2697
514
110
9315
8.6
930
135
78.8
2810
4015
111
5516
7.6
995
144
82.4
3011
0716
112
1917
6.9
1065
154
8632
1165
169
1286
186.
611
3016
489
.634
1230
178
1355
196.
712
0317
493
.236
1300
189
1426
207
1277
185
96.8
3813
7820
015
0021
7.7
1369
199
100.
440
1448
210
1577
228.
914
4921
010
442
1525
221
1656
240.
315
4322
410
7.6
4416
1023
317
3825
2.2
1630
236
111.2
4616
8824
518
2326
4.6
1722
250
114.
848
1770
257
1911
277.
418
2026
411
8.4
5018
5526
920
0129
0.4
1914
278
122
5219
5028
320
9530
4.1
2005
291
125.
654
2050
297
2192
318.
121
1031
912
9.2
(ISCE
ON
49)
(ISCE
ON
59)
(ISCE
ON
69L
)(IS
CEO
N 7
9)
R134
AR4
06A
R409
AR4
13A
R407
CR4
10A
R417
AR4
04A
R507
R408
AR4
03B
R422
ATe
mp
°CkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
gkP
Ag
kPA
g-5
0-7
1-5
09
-25
-23
-12
-23
1-4
8-6
7-4
521
-18
-15
-3-1
712
-46
-63
-39
33-1
1-6
7-8
24-4
4-5
9-3
346
-24
171
35-4
2-5
4-2
717
617
1528
1147
-40
-43
-49
-20
2976
1626
4022
6021
.4-3
8-3
7-4
3-1
241
9329
3953
3473
35.1
-36
-35
-30
-37
-455
111
3752
6746
8849
.6-3
4-2
8-2
4-3
14
6813
049
6682
6010
457
.2-3
2-2
1-1
6-2
314
8115
061
8198
7411
873
.7-3
0-1
4-9
-16
2495
172
7497
114
8913
890
.9-2
8-5
0-7
3411
019
588
114
132
105
157
110.
2-2
63
92
4511
821
910
313
315
112
317
813
0.2
-24
1419
1157
128
245
119
152
171
141
199
141.2
-22
2629
2170
136
273
135
173
193
161
220
163.
3-2
039
4033
8415
630
315
319
521
618
124
318
7.4
-18
4952
4498
177
334
171
219
240
203
267
212.
9-1
659
6557
114
200
367
191
243
265
227
295
240.
5-1
472
7871
130
224
402
211
270
292
251
320
254.
9-1
286
9285
147
249
438
233
297
320
277
348
285.
2-1
010
110
710
016
527
647
725
632
635
030
538
231
6.9
-811
812
311
718
430
451
828
035
738
233
441
235
0.7
-613
514
013
420
433
456
130
539
041
536
444
638
6.5
-415
315
815
222
636
560
733
242
445
039
648
340
5.1
-217
217
717
224
839
865
436
046
048
643
052
044
4.4
019
219
719
227
244
070
438
949
852
546
556
048
5.7
221
121
721
429
750
075
742
053
756
550
260
352
9.2
422
924
023
732
352
981
245
257
960
854
164
457
5.3
625
326
326
235
056
686
948
562
365
258
268
959
9.4
828
328
728
737
960
493
052
066
969
862
573
264
910
313
313
314
409
645
993
557
716
747
670
783
709.
712
342
340
342
441
688
1059
595
766
798
716
831
795.
114
372
368
372
474
732
1128
635
819
851
765
886
854.
416
403
397
404
508
779
1200
676
873
906
816
942
884.
718
436
428
437
544
828
1275
719
929
964
869
998
947.
420
469
461
471
582
880
1353
764
989
1024
920
1057
1013
.522
507
495
507
621
934
1435
811
1049
1087
980
1113
1083
.124
544
530
545
662
990
1520
859
1119
1152
1040
1179
1154
.826
584
567
585
705
1049
1608
910
1179
1221
1100
1244
1192
.728
626
605
626
750
1110
1701
962
1249
1291
1170
1313
1269
.130
668
645
670
796
1175
1797
1016
1329
1365
1240
1388
1349
.832
715
687
715
844
1242
1896
1073
1399
1442
1310
1462
1433
.834
761
730
762
895
1311
2000
1131
1479
1521
1380
1540
1521
.336
811
775
811
947
1384
2108
1192
1559
1604
1460
1620
1566
.838
863
822
863
1001
1460
2220
1254
1639
1689
1530
1700
1659
.840
915
871
920
1057
1539
2336
1319
1729
1778
1610
1784
1756
.342
972
922
970
1115
1621
2456
1386
1819
1870
1700
1872
1857
.544
1029
974
1030
1176
1707
2581
1455
1909
1966
1790
1964
1962
.346
1090
1029
1090
1238
1796
2710
1527
2009
2064
1880
2057
2016
4811
5310
8511
5013
0318
8828
4416
0121
0921
6719
7021
5121
27.6
5012
1711
4412
2013
7019
8529
8316
7722
0922
7320
6022
5022
43.4
5212
8712
0412
9014
4020
8531
2617
5623
1923
8221
6023
5823
6454
1356
1267
1360
1512
2188
3274
1837
2429
2496
2270
2464
2488
.7
TD254
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
PROPERTIES OF REFRIGERANTS
Properties of Refrigerants
Refrigerant R407cKLEA66
R480aFX10
R409aFX56
R409bFX57
R410aAZ20
R413aISCEON 49
R500 R502 R503 R507AZ50
R600aButane
R717Ammonia
Boiling Point at 101 kPa- °C -43.6 -43.5 -34.2 -36.6 -51.4 -35 -33.5 -45.4 -88.7 -46.7 -11.8 -33.3
Temp. Glide at 101 kPa K 7.2 0.7 7.1 7.7 0 7.1 0 0 0 0 0 0
Critical Temperature 'C 87.3 83.5 107 116 84.9 101.3 105.5 82. 2 195 70.9 135 133
Critical Pressure kPa 4820 4340 4500 4700 4950 4110 4420 4075 4340 3793 3631 11417
Latent Heat of Vapourisation
at 101 kPa kj/Kg
250.1 227.2 220.2 220.3 271.6 214.6 201 172 179.4 196.1 355.2
Vapour Pressureat 25°C kPa 1002.8 1147.9 644 692 1646.9 717.1 770 1160 4290 1286 351.8
Liquid Density at 25°C Kg/m³ 1139.22 1062.1 1215.9 1228.4 1083.8 1169.6 1160 1220 1230 1041.6 552.3
Vapour Density at 101 kPa Kg/m³ 4.507 4.712 4.91 4.881 4.064 5.272 5.3 4.79 6.03 5 449 4.392
Ozone Depletion Potential (ODP) 0 0.019 0.04 0.039 0 0 0.605 0.224 0.599 0 0 0
Global Warming Potential (GWP)
(CO²=1)
1370 3060 1530 1510 1300 1510 5210 5590 11700 3900 3 1
Flammability Limit at 25°C None None None None None Worst case of
Fraction-ation
flamm-able
None None None None 1.7% 15%
Variation in Composition of Blended Refrigerants in Case of LeakageIn the following, we make the distinction between:
• Nearazeotropicmixtures(havingalowtemperatureglidetypicallylowerthan3K)
• Azeotropicmixtures(havingatemperatureglideequaltozeroK)
R404a and R408a are near azeotropic mixtures with a glide lower than 1 K.
The composition of the mixtures does not change when a leak occurs in a homogeneous phase. That is the case at the evaporator outlet (superheated vapour) or at the condenser outlet (subcooled liquid).
By contrast, marked differences of behaviour appear between the different types of mixtures during a leak in the two phase region equilibrium.
For non-azeotropic mixtures, the ‘more volatile’ components escape in preceding order, altering to a great extent the composition of the mixture remaining in the installation, resulting in change of performance.
For near azeotropic or real azeotropic mixtures, leak rates of all components of the mixture are very close; thus during a leakage, com-position of refrigerant remaining in the installation is not affected significantly.
For all blended refrigerants it is stated by some manufacturers that after a leakage of 50% of the initial charge, changes in composition are less than 3% by weight.
Like R502 the new blended refrigerants must always be introduced in the liquid phase in the installation. Introduction in the gas phase, at the compressor suction, may increase the charging time of the installation and may alter performance of the mixture charged.
*For a non azeotropic mixture the change process liquid to vapour occurs over a range of temperatures (glide).
TD255
Please quote the stock number when ordering. Listed prices and specifications are subject to alteration without notice. For more information visit www.realcold.co.nz.
Tech
nica
l Dat
a
CONVERSION DATA
Summary of Common Conversion Factors
Length
Millimetres Centimetres Inches Feet Yards Metres Kilometres Miles1 0.1 0.03937 0.003281 0.0010936 0.001 0.000001 0.000000621410 1 0.3937 0.032808 0.010936 0.01 0.00001 0.00000521425.4 2.54 1 0.08333 0.027777 0.254 0.0000254 0.00001578304.8 30.48 12 1 0.3333 0.3048 0.0003048 0.0001893914.4 91.44 36 3 1 0.9144 0.0009144 0.00056821000 100 39.37 3.2808 1.0936 1 0.001 0.00062141,000,000 100,000 39,370 3280.8 1093.6 1000 1 0.62141,609,350 160,935 63,360 5280 1760 1609.35 1.60935 1
Mass
Grams Ounces Pounds Kilograms US Ton (Short) Imp Ton (Long) Metric Tonne1 0.03527392 0.00220462 0.001 0.05110231 0.0698426 0.05128.3496 1 0.0625 0.0283496 0.043125 0.04279 0.04283496453.593 16 1 0.453593 0.0005 0.0344642 0.034535931000 35.27392 2.20462 1 0.00110231 0.03984206 0.0001907,186 32,000 2000 907.186 1 0.89285 0.9071861,016,050 35,840 2240 1016.05 1.12 1 1.016051,000,000 35,273.92 2204.62 1000 1.10231 0.984206 1
Energy or Work
Joules (1 Joule = 107 Ergs)
Foot - Pounds Kilogram Metres
Litre - Atmosphere
HorsepowerHours
KilowattHours
KilogramsCalories
British Thermal Units
Lbs Carbon Oxidised with Perfect Efficiency
Lbs Water Evaporated from and at 100°C
1 0.7373 0.101937 0.0098705 0.063727 0.06278 0.0323795 0.039486 0.07642 0.0696621.3562 1 0.138255 0.013826 0.06505 0.063766 0.0332396 0.0012861 0.078808 0.05135269.81 7.233 1 0.09677 0.053653 0.052724 0.002343 0.009302 0.0663718 0.0595895101,3667 74,7386 10.333 1 0.043774 0.042794 0.0242 0.0961 0.056583 0.0499072,685,443 1,980,000 273,746 26,490.4 1 0.7457 641.477 2546.5 0.174 2.623,600,000 2,655,220 367,100 35,526.95 1.341 1 860.238 3415 0.234 3.524185.8291 3087.35 426.843 41.309 0.001558 0.0011623 1 3.9683 0.0329909 0.0045011054.198 778 107.5 10.40277 0.033927 0.032928 0.2519 1 0.04685 0.0010315387,041.6 11,352,000 1.569,527.5 151,894.66 5.733 4.275 3,677.74 14,600 1 15.051,023,000 754,525 104.320 10,096.77 0.3811 0.2841 244.44 970.4 0.066466 1
Volume and Capacity
Cubic Inches
Cubic Feet
Cubic Feet
Litres US Quarts US Gallons Imperial Gallons
US Bushels Water at Max Density 4°CLiquid Dry Liquid Dry Pounds Kgs
1 0.035787 0.042143 0.016384 0.01731 0.01488 0.004329 0.003721 0.0036065 0.034651 0.0361275 0.01638721728 1 0.037037 28.317 29.92208 25.713 7.48052 6.4282 6.2321 0.803564 62.4283 28.31746,656 27 1 764.56 807.895 694.278 201.974 173.569 168.266 21.6962 1685.56 764.55961,023.4 35.3145 1.307941 1000 1056.68 908.1 264.17 227.02 220.083 28.38 2204.62 100061.0234 0.0353145 0.001308 1 1005668 0.9081 0.26417 0.22702 0.22083 0.02838 2.20462 157.75 0.03342 0.001238 0.94636 1 0.8595 0.25 0.2149 0.20828 0.02686 2.08636 0.9463567.18 0.03888 0.00144 1.1009 1.1635 1 0.2909 0.25 0.24235 0.03125231 0.133681 0.004951 3.78543 4 3.4378 1 .08595 0.833111 0.10743 8.34545 3.78543268.75 .015552 0.00576 4.404 4.654 4 1.1635 1 0.96932 0.125277.274 0.160459 0.0059429 4.54374 4.80128 4.1267 1.20032 1.0317 1 0.12896 10.0172 4.543732150 1.24446 0.04609 35.238 37.2353 32 9.3088 8 7.81457 127.6798 0.0160184 0.035929 0.453592 0.4793 0.119825 0.0998281 1 0.453593
Pressure
psi atms. Ft. Hd H2O @ 20°C
Inches H2O Kg/cm² MetresH2O
Inches Hg. at 20°C
mm Hg. Cm Hg. Bar Millibar (mb)
KPa
1 0.068 2.31 27.72 0.07 0.704 2.043 51.884 5.188 0.069 68.947 6.89514.696 1 33.659 407.513 1.033 10.351 30.019 762.48 76.284 1.013 1013 101.3250.433 0.029 1 12 0.03 0.305 0.884 22.452 2.245 0.03 29.837 2.9840.36 0.0025 .0833 1 0.0025 0.025 0.074 1.871 0.187 0.0025 2.486 0.24914.233 0.968 32.867 394.408 1 10.018 29.054 737.959 73.796 0.981 980.662 98.0661.422 0.097 3.287 39.37 0.099 1 2.905 73.796 7.379 0.098 98.066 9.8070.489 0.033 1.131 13.575 0.034 0.345 1 25.4 2.54 0.034 33.753 3.3750.019 0.0013 0.045 0.534 0.0014 0.0136 0.039 1 0.1 0.001 1.329 0.1330.193 0.0131 0.455 5.34 0.014 0.136 0.393 10 1 0.0133 13.29 1.32814.503 0.987 33.514 402.164 10.2 10.211 29.625 752.47 75.247 1 1000 1000.014 0.0009 0.033 0.402 0.001 0.0102 0.029 0.752 0.075 0.001 1 0.10.145 0.0098 0.335 4.021 0.01 0.102 0.296 7.525 0.0752 0.01 10 1
TERMS & CONDITIONS OF TRADE1. DEFINITIONS
1.1 “Realcold” shall mean Realcold Limited., or any agents or employees thereof.
1.2 “Customer” shall mean the Customer, any person act-ing on behalf of and with the authority of the Customer, or any person purchasing products and services from Realcold.
1.3 “Goods” shall mean:
1.3.1 all Goods of the general description specified on the front of this agreement and supplied by Real-cold to the Customer; and
1.3.2 all Goods supplied by Realcold to the Customer; and
1.3.3 all inventory of the Customer that is supplied by Realcold; and
1.3.4 all Goods supplied by Realcold and further identi-fied in any invoice issued by Realcold to the Cus-tomer, which invoices are deemed to be incorpo-rated into and form part of this agreement; and
1.3.5 all Goods that are marked as having been sup-plied by Realcold or that are stored by the Cus-tomer in a manner that enables them to be identi-fied as having been supplied by Realcold; and
1.3.6 all of the Customer’s present and after-acquired Goods that Realcold has performed work on or to or in which goods or materials supplied or fi-nanced by Realcold have been attached or incor-porated.
1.3.7 The above descriptions may overlap but each is independent of and does not limit the others.
1.4 “Goods and Services” shall also mean all goods, prod-ucts, services and advice provided by Realcold to the Customer and shall include without limitation the design, manufacture, development, sale, installation, repair and maintenance of industrial refrigeration equipment and the supply of componentry and parts and all charges for labour, hire charges, insurance charges, or any fee or charge associated with the supply of Goods and Ser-vices by Realcold to the Customer.
1.5 “Price” shall mean the cost of the Goods and Services as agreed between Realcold and the Customer and includes all disbursements eg charges Realcold pay to others on the Customer’s behalf subject to clause 4 of this contract.
2. ACCEPTANCE
2.1 Any instructions received by Realcold from the Customer for the supply of Goods and Services shall constitute a binding contract and acceptance of the terms and con-ditions contained herein.
3. COLLECTION AND USE OF INFORMATION
3.1 The Customer authorises Realcold to collect, retain and use any information about the Customer, for the purpose of assessing the Customer’s credit worthiness, enforcing any rights under this contract, or marketing any Goods and Services provided by Realcold to any other party.
3.2 The Customer authorises Realcold to disclose any infor-mation obtained to any person for the purposes set out in clause 3.1.
3.3 Where the Customer is a natural person the authorities under clauses 3.1 and 3.2 are authorities or consents for the purposes of the Privacy Act 1993.
4. PRICE
4.1 Where no price is stated in writing or agreed to orally the Goods and Services shall be deemed to be sold at the current amount as such Goods and Services are sold by Realcold at the time of the contract.
4.2 The price may be increased by the amount of any rea-sonable increase in the cost of supply of the Goods and Services that is beyond the control of Realcold between the date of the contract and delivery of the Goods and Services.
5. PAYMENT
5.1 Payment for Goods and Services shall be made in full on or before the 20th day of the month following the date of the invoice (“the due date”). Progress payments apply to large contracts.
5.2 Interest may be charged on any amount owing after the due date at the rate of 2.5% per month or part month.
5.3 Any expenses, disbursements and legal costs incurred by Realcold in the enforcement of any rights contained in this contract shall be paid by the Customer, including any reasonable solicitor’s fees or debt collection agency fees.
5.4 Receipt of a cheque, bill of exchange, or other negotiable instrument shall not constitute payment until such nego-tiable instrument is paid in full.
5.5 A deposit may be required.
6. QUOTATION
6.1 Where a quotation is given by Realcold for Goods and Services:
6.1.1 Unless otherwise agreed the quotation shall be valid for thirty (30) days from the date of issue; and
6.1.2 The quotation shall be exclusive of goods and services tax unless specifically stated to the con-trary;
6.1.3 Realcold reserve the right to alter the quotation because of circumstances beyond its control.
TERMS & CONDITIONS OF TRADE6.2 Where Goods and Services are required in addition to
the quotation the Customer agrees to pay for the addi-tional cost of such Goods and Services.
7. RISK
7.1 The Goods and Services remain at Realcold’s risk until delivery to the Customer.
7.2 Delivery of Goods and Services shall be deemed com-plete when Realcold gives possession of the Goods and Services directly to the Customer or possession of the Goods and Services is given to a carrier, courier, or other bailee for purposes of transmission to the Customer.
8. TITLE AND SECURITY (PERSONAL PROPERTY SECURITIES ACT 1999)
8.1 Title in any Goods and Services supplied by Realcold passes to the Customer only when the Customer has made payment in full for all Goods and Services pro-vided by Realcold and of all other sums due to Realcold by the Customer on any account whatsoever. Until all sums due to Realcold by the Customer have been paid in full, Realcold has a security interest in all Goods and Services.
8.2 If the Goods and Services are attached, fixed, or incor-porated into any property of the Customer, by way of any manufacturing or assembly process by the Customer or any third party, title in the Goods and Services shall remain with Realcold until the Customer has made pay-ment for all Goods and Services, and where those Goods and Services are mixed with other property so as to be part of or a constituent of any new Goods and Services, title to these new Goods and Services shall deemed to be assigned to Realcold as security for the full satisfac-tion by the Customer of the full amount owing between Realcold and Customer.
8.3 The Customer gives irrevocable authority to Realcold to enter any premises occupied by the Customer or on which Goods and Services are situated at any reason-able time after default by the Customer or before default if Realcold believes a default is likely and to remove and repossess any Goods and Services and any other property to which Goods and Services are attached or in which Goods and Services are incorporated. Realcold shall not be liable for any costs, damages, expenses or losses incurred by the Customer or any third party as a result of this action, nor liable in contract or in tort or otherwise in any way whatsoever unless by statute such liability cannot be excluded. Realcold may either resell any repossessed Goods and Services and credit the Customer’s account with the net proceeds of sale (after deduction of all repossession, storage, selling and other costs) or may retain any repossessed Goods and Ser-vices and credit the Customer’s account with the invoice value thereof less such sum as Realcold reasonably determines on account of wear and tear, depreciation, obsolescence, loss or profit and costs.
8.4 Where Goods and Services are retained by Realcold pursuant to clause 8.3 the Customer waives the right to receive notice under s.120 of the Personal Property Se-curities Act 1999 (“PPSA”) and to object under s.121 of the PPSA.
8.5 The Company may register a Financing Statement over the Goods and the customer shall agree to waive the right to a verification statement for purposes of s.148 of the PPSA.
8.6 The following shall constitute defaults by the Customer:
8.6.1 Non payment of any sum by the due date.
8.6.2 The Customer intimates that it will not pay any sum by the due date.
8.6.3 Any Goods and Services are seized by any other creditor of the Customer or any other creditor inti-mates that it intends to seize Goods and Services.
8.6.4 Any Goods and Services in the possession of the Customer are materially damaged while any sum due from the Customer to Realcold remains un-paid.
8.6.5 The Customer is bankrupted or put into liquida-tion or a receiver is appointed to any of the Cus-tomer’s assets or a landlord distrains against any of the Customer’s assets.
8.6.6 A Court judgment is entered against the Custom-er and remains unsatisfied for seven (7) days.
8.6.7 Any material adverse change in the financial po-sition of the Customer.
9. SECURITY INTEREST FOR SERVICE PROVIDERS
9.1 The Customer gives Realcold a security interest in all of the Customer’s present and after-acquired property that Realcold has performed services on or to or in which goods or materials supplied or financed by Realcold have been attached or incorporated.
10. PAYMENT ALLOCATION
10.1 Realcold may in its discretion allocate any payment re-ceived from the Customer towards any invoice that Real-cold determines and may do so at the time of receipt or at any time afterwards and on default by the Customer may reallocate any payments previously received and allocated. In the absence of any payment allocation by Realcold, payment shall be deemed to be allocated in such manner as preserves the maximum value of Re-alcold’s purchase money security interest in the Goods and Services.
TERMS & CONDITIONS OF TRADE11. GENERAL LIEN
11.1 The Customer agrees that Realcold may exercise a gen-eral lien against any Goods and Services or property be-longing to the Customer that is in the possession of Re-alcold for all sums outstanding under this contract and any other contract to which the Customer and Realcold are parties.
11.2 If the lien is not satisfied within seven (7) days of the due date Realcold may, having given notice of the lien at its option either:
11.2.1 Remove such Goods and Services and store them in such a place and in such a manner as Realcold shall think fit and proper and at the risk and ex-pense of the Customer; or
11.2.2 Sell such Goods and Services or part thereof upon such terms as it shall think fit and apply the pro-ceeds in or towards discharge of the lien and costs of sale without being liable to any person for damage caused.
12. DISPUTES AND RETURN OF GOODS
12.1 No claim relating to the Goods and Services will be con-sidered unless made within seven (7) days of delivery.
12.2 No Goods will be accepted for return without the prior consent of Realcold. Any Goods accepted for return will be subject to a 10% restocking fee and must be in resale-able undamaged condition and in original packaging.
13. LIABILITY
13.1 The Consumer Guarantees Act 1993, the Sale of Goods Act 1908, the Fair Trading Act 1986 and other statutes may imply warranties or conditions or impose obliga-tions upon Realcold which cannot by law (or which can only to a limited extent by law) be excluded or modified. In respect of any such implied warranties, conditions or terms imposed on Realcold, Realcold’s liability shall, where it is allowed, be excluded or if not able to be ex-cluded only apply to the minimum extent required by the relevant statute.
13.2 Except as otherwise provided by clause 13.1 Realcold shall not be liable for:
13.2.1 Any loss or damage of any kind whatsoever, aris-ing from the supply of Goods and Services by Realcold to the Customer, including consequen-tial loss whether suffered or incurred by the Cus-tomer or another person and whether in contract or tort (including negligence) or otherwise and ir-respective of whether such loss or damage arises directly or indirectly from Goods and Services pro-vided by Realcold to the Customer; and
13.2.2 The Customer shall indemnify Realcold against all claims and loss of any kind whatsoever how-ever caused or arising and without limiting the generality of the foregoing of this clause whether caused or arising as a result of the negligence of Realcold or otherwise, brought by any person in connection with any matter, act, omission, or error by Realcold its agents or employees in connection with the Goods and Services.
14. WARRANTY
14.1 Manufacturer’s warranty applies where applicable.
14.2 Any written warranty provided by Realcold to the Cus-tomer shall also form part of these terms and conditions of trade.
15. COPYRIGHT AND INTELLECTUAL PROPERTY
15.1 Realcold, owns and has copyright in all designs, speci-fications, documents, work and software produced by Realcold in connection with the Goods and Services pro-vided pursuant to this contract and the client may use the Goods and Services only if paid for in full and for the purpose for which they were intended and supplied by Realcold.
16. CONSUMER GUARANTEES ACT
16.1 The guarantees contained in the Consumer Guarantees Act 1993 are excluded where the Customer acquires Goods and Services from Realcold for the purposes of a business in terms of section 2 and 43 of that Act.
17. PERSONAL GUARANTEE OF COMPANY DIRECTORS OR TRUSTEES
17.1 If the Customer is a company or trust, the director(s) or trustee(s) signing this contract, in consideration for Real-cold agreeing to supply Goods and Services and grant credit to the Customer at their request, also sign this contract in their personal capacity and jointly and sever-ally personally undertake as principal debtors to Real-cold the payment of any and all monies now or here-after owed by the Customer to Realcold and indemnify Realcold against non-payment by the Customer. Any personal liability of a signatory hereto shall not exclude the Customer in any way whatsoever from the liabilities and obligations contained in this contract. The signato-ries and Customer shall be jointly and severally liable under the terms and conditions of this contract and for payment of all sums due hereunder.
TERMS & CONDITIONS OF TRADE18. MISCELLANEOUS
18.1 Realcold shall not be liable for delay or failure to perform its obligations if the cause of the delay or failure is be-yond its control.
18.2 Failure by Realcold to enforce any of the terms and con-ditions contained in this contract shall not be deemed to be a waiver of any of the rights or obligations Realcold has under this contract.
18.3 If any provision of this contract shall be invalid, void or il-legal or unenforceable the validity existence, legality and enforceability of the remaining provisions shall not be af-fected, prejudiced or impaired.
19. OVERSEAS CUSTOMER - Ownership and Risk
If the Customer is not located in New Zealand, Clause 8 & 9 do not apply and are replaced by the following:
19.1 The ownership and legal title of the Goods shall remain with Realcold until:
19.1.1 payment in full is made for the Goods; and
19.1.2 any other moneys owing by the Customer to Real-cold have been paid in full.
19.2 Notwithstanding that ownership in the Goods may not have passed to the Customer risk in the Goods shall pass to the Customer when the Goods are delivered to the Customer or into the custody of the party acting on the Customer’s behalf and the Customer shall be obliged to insure the Goods from the time of delivery to the Cus-tomer and pending payment in full insure the Goods in the name of Realcold and the Customer for their respec-tive interest.
19.3 If payment is over due in whole or in part in respect of any of the Goods Realcold may (without prejudice to any of its other rights) recover and/or resell the Goods or the mixed goods referred to in clause 19.6 or any of them and may enter upon the Customer’s premises or any other place where the Goods and/or the mixed goods are stored by its servants or agents for that purpose (and the Customer grants to Realcold an irrevocable right and authority to so recover, re enter and re sell), provided that Realcold may only recover and resell for its own account sufficient of the Goods and/or the mixed goods to satisfy all unpaid liability in respect of the Goods and the costs of resale. If any excess is recovered by RE, it shall not be liable in damages but shall account for the excess to the Customer.
19.4 Until payment is made in full by the Customer for the Goods, the Customer holds the Goods as bailee for Re-alcold and will store the Goods in such a manner that they are clearly identifiable as the property of Realcold and will keep separate records in respect of the Goods.
19.5 If the Goods are sold or otherwise disposed of by the Customer prior to payment in full, the Customer will have been deemed to have done so as agent for Realcold and the proceeds of such sale will be the property of Re-alcold. The Customer will hold the proceeds of such sale on trust, on account for RE, and keep them in a separate fund from its own money.
19.6 If any of the Goods are mixed or incorporated in other Goods (the “mixed goods”) before payment, the Custom-er agrees that the property in the mixed goods shall be and remain with Realcold until such payment has been made in full. The Customer shall hold the mixed goods as bailee for Realcold and will store the mixed goods in such a manner that they are clearly identifiable as the property of Realcold and will keep separate records in respect of the same. If the Customer sells the mixed goods it will hold the proceeds of such sale on trust for Realcold and will account to Realcold for the value of the Goods and keep the proceeds in a fund separate from its own money and will keep separate records in respect of such money.
19.7 Where Realcold has reasonable cause to believe:
19.7.1 The Customer has not strictly complied with these Terms and Conditions and, in particular, default of payment in accordance with clause 5; or
19.7.2 The Customer has or will commit an act of bank-ruptcy or (being a company) has had a receiver appointed or about to be appointed, or is de-clared insolvent; Realcold may recover any or all of the Goods or the mixed goods and re sell the Goods or the mixed goods and for such pur-pose may at any time of the day or night enter by force if necessary upon any promises where such Goods or mixed goods are reasonably thought to be stored (and the Customer grants to Realcold an irrevocable right and authority to so recover, re enter and re sell).
19.8 In exercising its rights pursuant to this clause, Realcold shall be entitled to deduct from any sale of Goods or mixed goods recovered from the Customer all the liabili-ties and expenses (including legal expenses) incurred by Realcold in enforcing or attempting to enforce its rights pursuant to this clause 19.
Catalogue
Index
IndexA
Accumulators CA60
AC-Tabs AC33
Air Conditioning CC78
Air Conditioning Thermostats AC36, CT136
Air Cooled CP202
Air Cooled Condensers CP209
AirDefrostCP212–CP215
Allen Key CT132
Ammonia IN171, IN183
Anti Siphoning AC34
Auto Purger IN181, IN182
Axial In-Line Fans AC46
B
Ball Valves CV148
Below Wall Unit AC35
Bending Springs CT132
Bernzomatic CB62
Boots AC42
Brackets & Bases AC27
Brass Fittings CF100, CF101
Brazing Alloy CB61
Bulk Head AC07, AC14
C
Capacity Controls CP208
Capillary CT137
Capillary Service Packs CT137
Capillary Tools CT137
Carel CE95
Carly CS126
Carly Turboil CO117
Cassette AC07, AC08, AC14
Ceiling Fan AC44
Centrifugal In-Line Fans AC46
Charging Equipment CT130
Charging Hoses CT127
Check Valves CV150, IN183
Chilled Water Packages CP222
Commercial Thermostats CT135
Compact Pumps AC34
Components & Fittings AC36
Compressor Lubricants CL114
Compressor Receiver CP206
Compressors CX167, CP223
Condensate Drain AC30, AC31
Condensate Pumps AC32, AC35
Condensers - Ammonia CP209
CondensingUnitsCX167,CP196–CP201,CP223
Control Panels CE96
Control Valves - Steel IN177
Cool Breeze AC18
Copeland CP203
CopelandScrollCC75–CC79,CP207,CP208
Copper Fittings CF102
Couplers CT128
Crankcase Heaters CC73
Cushion Side Entry Box AC42
Custom Build CP204
Custom Design CP199, CP222
D
Danfoss IN174
Deburring Tool CT130
Defrost Controls CD88, CD89
Defrost Safety CD89
Diffuser AC40, AC41
Discharge Line Mufflers CD94
Domestic Thermostats CT135
Down Discharge AC20
Drainage AC28
DriersCD90–CD94
Dual Pressure Controls CP119
Ducted AC09
Duct Fittings AC39
Ducting Accessories AC38
E
Easypack CP199, CP200
Eclipse Air Curtains AC17
Eggcrate Grille AC43
Electrical AC36
Electric Defrost CP213, CP214, CP215
Electronic Controls CE95, CE96
Energy - Recovery Ventilation AC16
Evaporative Air Conditioning AC18
EvaporativeCoolingAC24–AC26
Evaporator Mounting Kits CF106
Evaporator Range CP216, CP217
Expander Kit CT130
F
Fan Blades CF99
Fan Motor Assembly CF98
Fan Motors CF97
FansAC44,AC46–AC50,CF99
Farm Refrigeration CP202
Fasteners CF103, CF104
Filter Fitted CP208
Fin Combs CT133
FittingsCF100–CF108
Fittings & Fasteners CF103, CF104
Fixed Speed AC12
Flange Kits IN176
Flexible Ducting AC38
Flica CV139
Float Controls IN180
Floor Console AC14
Floor Mount AC07
Floor Mounted AC06
FrascoldCC80–CC87,CP199,CP204–CP206
Free Match AC14
G
Gas Sensors IN187
Gauges CT128
Gauge Valves IN179
Geneglace CP221
Gree AC13
GreeElectricAC11–AC16
GreenleafCC63–CC65
Grills AC44
H
Hand Regulating Valves IN171
Hand Shut-Off Valves CV149
HansenIN170–IN193
Hanwest CP210
Hard Drawn Copper CT137, CT138
Heat Exchangers CH109
Heat Pump AC35
Heat Pumps AC04
Heat Transfer System AC50
Henry IN179
Hi Flow Pumps AC32
High-WallAC04,AC05,AC12–AC14
Hi Lift Pumps AC32
Horizontal Receivers CR125
HoshizakiCP218–CP220
I
IceMachinesCP218–CP221
Individual Pilot Applications IN173
Industrial Pressure Gauges IN179
In-Line Filter AC34
Inspection Mirrors CT133
InsulationCI110–CI113
Insulation Accessories CI113
Insulclamp CF107
Inverter AC05
L
Leak Detectors CT130
Level Probes IN180
Level Switch IN180
Line Tap Valves CV151
Liquid Line Assembly CP207
Liquid Receiver Valves CV148
Locksets CF108
Lubricants CL114, CL115
L’UniteCP196–CP199
L’Unite Sealed CC68, CC69, CC73
L’Unite Sealed R134a CC67
L’Unite Sealed R404a CC66
L’Unite Sealed Rotary CC72
M
Manifold Sets CT127
Marine Condenser CP210
Mastercool Tools CT130
MaxflexCI110–CI112
Maxvent AC40, AC41, AC49, AC50
MitsubishiHeavyIndustriesAC04–AC08
Mixed Flow AC46
Mixflo AC48
Mobile Model AC22
Mueller CV148, CV149
Multi AC07, AC14
Multi Head AC15
N
Neck Adapter AC42
O
Oil Control Systems CO116, CO118
Oil Drain Valves IN186
Oil Injector CT133
Oil Pump CT133
Oil Separator CO117, CP207
Oil Separators CO118
Outdoor Units AC07
P
Parker IN191
Parker Hannifin CV145
Partial Defrost CP214
Pinch Off Tool CT133
Plenums AC23
Pre-Insulated AC28
PressureControlsCP119–CP121,CP208
Pressure Pilots IN174
Pressure Regulators CV146, IN172
Pressure Relief Valves CV149
Pump Accessories IN189
R
Ranco CP119, CP120
Ratchet Wrenches CT130
Realcold CP204
Realcold Milk Vat CP202
Realpack CP201
Receivers CR124
Recovery Cylinders CT129
Recovery System CT129
RectorsealCC63–CC65
Refillable Filter CP208
Refractometers CT134
Refrigerant CR122, CR123
RefrigerantPumpAccessoriesIN189–IN190
Refrigerant Pumps IN188
Refrigeration CC79
Reversing Valve AC37
Roof Fan Kits AC45
Roof Ventilation AC45
Rotalock Valves CC73, CV148
S
Saginomiya CP119
Schrader Valves CV151
Sheet Insulation CI111
Shut-Off Valves IN179
Side Discharge AC21
Sightglass CP207
Sight Glasses CS126, IN180
Soft Drawn Copper CT138
Solenoid Coils CV144, IN191
Solenoid Valves CV144, IN186
Solid State Relays CC74
SparesSpares153–Spares166
Spares For Pumps AC35
SporlanCD90–CD93,CS126,CV140,
CV143, CV147
Sporlan J8 CV141
SteelfortCR124,CR125,CP209–CP215
Stepped Spigot AC42
Stop Check Valves IN171
Stop Valves IN171, IN186
Suction Line CP207, CP208
Supermarket Pump AC33
T
Tape CI112
Tecumseh Europe CP196
TestEquipmentCT127–CT129,CT130
Testing Equipment CT134
Thermometers CT134
Thermoplastic - Nylon CF105
ThermostaticExpansionValvesCV139–CV141
Thermostats AC36, CT135, CT136
ToolsCT130–CT133
Top Discharge AC21
Transducer Valves IN179
Tube CT137, CT138
Tube Benders CT132
Tube Cutters CT130
Tube Insulation CI110
TX Valve CV143
U
Under Ceiling AC10
Unijet AC41
Univent AC40
Universal Pump AC33
V
Vacuum Gauge CT130
Vacuum Pumps CT129
ValvesCV139–CV151
Valves-SparesIN192–IN193
Vertical Receivers CR124
Vibration Eliminators CV152
W
Wall Mount AC07
Warranty CX167, CP223
Warrenty AC51
Water Heating CP202
Weatherproof Cowl AC44
Window - Wall AC11
Branch Locations
Auckland Branch / Head Office9 Prescott Street, Penrose 1061PO Box 12072, Penrose 1642Orders Direct Line: 0800 11 66 90Orders Direct Fax: 09 526 5748Phone: 09 526 5700Fax: 09 526 5721Email: [email protected] website: www.airzonenz.co.nzRealcold website: www.realcold.co.nz
Christchurch71 Harman Street, Addington, Christchurch 8024PO Box 9150, Tower Junction, Christchurch 8149Phone: 03 338 8084 Fax: 03 338 9938Email: [email protected]
Dunedin18 Roberts Street, Dunedin 9016PO Box 2536, Dunedin 9044Phone: 03 467 7106 Fax: 03 467 7107Email: [email protected]
Hamilton43 Lake Road, Frankton, Hamilton 3204PO Box 5238, Frankton, Hamilton 3242Phone: 07 848 2111 Fax: 07 848 2333Email: [email protected]
HastingsCnr St Aubyn Street East & Miller Street Hastings 4122PO Box 488, Hastings 4156Phone: 06 870 3714 Fax: 06 870 3726Email: [email protected]
North HarbourUnit C, 28 Canaveral Drive, Albany 0632PO Box 305354, Triton PlazaNorth Shore City 0757Phone: 09 477 0274 Fax: 09 478 2309Email: [email protected]
Palmerston NorthUnit 2, 597-599 Tremaine Avenue PO Box 4368, Manawatu Mail Centre Palmerston North 4442Phone: 06 357 9101 Fax: 06 357 9103Email: [email protected]
Tauranga5 Barberry Street, Judea, Tauranga 3110PO Box 15610, Tauranga 3144Phone: 07 571 0096 Fax: 07 571 0097Email: [email protected]
Wellington54 Fitzherbert Street, Petone, Lower Hutt 5012PO Box 38527, Wellington Mail Centre Lower Hutt 5045Phone: 04 569 3072 Fax: 04 568 2210Email: [email protected]
Whangarei Unit A1, 7 - 11 Nell Place, Raumanga Whangarei 0110PO Box 25056, Whangarei Mail CentreWhangarei 0148Phone: 09 430 4476 Fax: 09 430 7465Email: [email protected]