22nd floor - slab s20 - top

3
 Job No. Sheet No. Revision. ARUP Ove Arup & Partners 214807 Calculation Spreadsheet Member/Location Slab S20 Supporting Edge Job Title Ho Man Tin Made By TV Filename Design of Slab - Tower 2 - 22nd floor Date Oct-12 Checked by 1. DESIGN PA RAMETERS Section Properties Tension Reinforcement  Effective Width b = 1000 mm Member Depth h = 150 mm Steel Bars for Support of Long Span Norminal cover to compression rebar = 30 mm No. of layers = 1 Norminal cover to tension rebar = 25 mm Diameter = 10 mm Spacing c/c = 200 mm Material Properties No. per unit width = 5.0 fcu = 45 N/mm2 fy = 460 N/mm2 Steel Bars for Support of Short Span fyv = 460 N/mm2 No. of layers = 1 Diameter = 10 mm Compression Reinforcement Spacing c/c = 200 mm Diameter = 10 mm No. per unit width = 5.0 Spacing c/c = 200 mm 2. BENDING REINFORCEMENT DESI GN (ULTIMATE LI MIT DESIGN CHECK) Tension Steel Bars for Support of Long Span Maximium Design Ulitmate Bending Moment Mx = 0.00 kNm Effective Depth d = 120.0 mm z = d[0.5+ (0.25-K /0.9)^ 0.5] = 120 mm >0.95d = 114 mm M/ (bdf  cu ) = 0.000 < 0.156 Compression Steel is Not Required!  As Required = M/(0.87fy*z) = 0 mm 2 Check Min. Steel : 0.13%bh = 195 mm 2 195 As Provided = 393 mm 2 > Required As, OK! Total % steel = 0.26% Provide T 10 - 200 Tension Steel Bars for Support of Short Span Maximium Design Ulitmate Bending Moment My = 0.00 kNm Effective Depth d = 110.0 mm z = d[0.5+ (0.25-K /0.9)^ 0.5] = 110 mm >0.95d = 105 mm M/ (bd f  cu ) = 0.000 < 0.156 Compression Steel is Not Required!  As Required = M/(0.87fy*z) = 0 mm 2 Check Min. Steel: 0.13%bh = 195 mm 2 As Provided = 393 mm 2 > Required As, OK! Total % steel = 0.26% Provide T 10 - 200 Compression Steel Bars (Provide norminal steel) Effective Depth d = 115.0 mm As' Provided = 393 mm 2 Provide T 10 - 200 2-Way Slab_Typical

Upload: thanhaa

Post on 01-Nov-2015

5 views

Category:

Documents


1 download

DESCRIPTION

22nd Floor - Slab S20 - Top

TRANSCRIPT

  • Job No. Sheet No. Revision.

    ARUP Ove Arup & Partners 214807Calculation Spreadsheet

    Member/LocationSlab S20 Supporting Edge

    Job Title Ho Man Tin Made By TV Filename

    Design of Slab - Tower 2 - 22nd floor Date Oct-12 Checked by

    1. DESIGN PARAMETERS

    Section Properties Tension Reinforcement

    Effective Width b = 1000 mm

    Member Depth h = 150 mm Steel Bars for Support of Long Span

    Norminal cover to compression rebar = 30 mm No. of layers = 1

    Norminal cover to tension rebar = 25 mm Diameter = 10 mm

    Spacing c/c = 200 mm

    Material Properties No. per unit width = 5.0

    fcu = 45 N/mm2

    fy = 460 N/mm2 Steel Bars for Support of Short Span

    fyv = 460 N/mm2 No. of layers = 1

    Diameter = 10 mm

    Compression Reinforcement Spacing c/c = 200 mm

    Diameter = 10 mm No. per unit width = 5.0

    Spacing c/c = 200 mm

    2. BENDING REINFORCEMENT DESIGN (ULTIMATE LIMIT DESIGN CHECK)

    Tension Steel Bars for Support of Long SpanMaximium Design Ulitmate Bending Moment Mx = 0.00 kNm

    Effective Depth d = 120.0 mm

    z = d[0.5+(0.25-K/0.9)^0.5]

    = 120 mm >0.95d = 114 mm

    M/(bd2fcu) = 0.000 < 0.156 Compression Steel is Not Required!

    As Required = M/(0.87fy*z) = 0 mm2

    Check Min. Steel: 0.13%bh = 195 mm2

    195

    As Provided = 393 mm2

    > Required As, OK!

    Total % steel = 0.26%

    Provide T 10 - 200

    Tension Steel Bars for Support of Short SpanMaximium Design Ulitmate Bending Moment My = 0.00 kNm

    Effective Depth d = 110.0 mm

    z = d[0.5+(0.25-K/0.9)^0.5]z = d[0.5+(0.25-K/0.9)^0.5]

    = 110 mm >0.95d = 105 mm

    M/(bd2fcu) = 0.000 < 0.156 Compression Steel is Not Required!

    As Required = M/(0.87fy*z) = 0 mm2

    Check Min. Steel: 0.13%bh = 195 mm2

    As Provided = 393 mm2

    > Required As, OK!

    Total % steel = 0.26%

    Provide T 10 - 200

    Compression Steel Bars (Provide norminal steel)

    Effective Depth d = 115.0 mm

    As' Provided = 393 mm2

    Provide T 10 - 200

    2-Way Slab_Typical

  • Job No. Sheet No. Revision.

    ARUP Ove Arup & Partners 214807Calculation Spreadsheet

    Member/LocationSlab S20 Supporting Edge

    Job Title Ho Man Tin Made By TV Filename

    Design of Slab - Tower 2 - 22nd floor Date Oct-12 Checked by

    3. SHEAR REINFORCEMENT DESIGN (ULTIMATE LIMIT DESIGN CHECK)

    Shear Check for Continuous Support

    Maximum Design Shear Force of Long Span Vsx = 0.00 kN

    100As/bd = 0.33

    vc= 0.69 N/mm2

    v= 0.00 N/mm2

    Shear Reinforcement is Not Required!

    Maximum Design Shear Force of Short Span Vsy = 0.00 kN

    100As/bd = 0.36vc= 0.72 N/mm

    2

    v= 0.00 N/mm2

    Shear Reinforcement is Not Required!

    Shear Check for Dis-Continuous Support

    Maximum Design Shear Force of Long Span Vsx = 14.12 kN

    100As/bd = 0.33vc= 0.69 N/mm

    2

    v= 0.12 N/mm2

    Shear Reinforcement is Not Required!

    Maximum Design Shear Force of Short Span Vsy = 10.83 kN

    100As/bd = 0.36vc= 0.72 N/mm

    2

    v= 0.10 N/mm2

    Shear Reinforcement is Not Required!

    2-Way Slab_Typical