Dimensions Length (without casters) 59” Length (with casters) 74 ½” Width 35 3/8” Height (without casters) 52” Height (with casters) 61 3/4” Unit Weight 1,400 Lbs. 35 Ton Rental Air Handling Unit Unit Performance / Data General CAT / CLASS XXXX-XX Manufacturer Smart Family of Cooling Products Unit Model Number DDA05Q Equipment Insurance Value NA Duct/Hose Connections (1) 20” Supply / (1) x 20” Return Filter Size QTY (4) 16” x 20” Filter Type 2” Washable Media Electrical Certification ETL listed for UL 1995, CSA 236 STD 22.2 Single Point Power Supply 460V/3PH/60HZ Connections Single point Series 16 Cam-Lok connections Cooling Amps 11.6 A (460V) Heating Amps 11.6 A Unit MFS 32 A Generator Size 46 kW

Upload: others

Post on 27-Sep-2020

55 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 35 Ton Rental Air Handling Unit...35 Ton Rental Air Handling Unit Unit Features: § Direct drive High Static plenum fan with 10hp TEFC motor § Maximum rated static pressure of 5.6

DimensionsLength(withoutcasters) 59”Length(withcasters) 74½”Width 353/8”Height(withoutcasters) 52”Height(withcasters) 613/4”UnitWeight 1,400Lbs.

35 Ton Rental Air Handling Unit Unit Performance / Data

GeneralCAT/CLASS XXXX-XXManufacturer SmartFamilyofCoolingProductsUnitModelNumber DDA05Q EquipmentInsuranceValue NADuct/HoseConnections (1)20”Supply/(1)x20”ReturnFilterSize QTY(4)16”x20”FilterType 2”WashableMediaElectricalCertification ETLlistedforUL1995,CSA236STD22.2SinglePointPowerSupply 460V/3PH/60HZConnections SinglepointSeries16Cam-LokconnectionsCoolingAmps 11.6A(460V)HeatingAmps 11.6AUnitMFS 32AGeneratorSize 46kW

Page 2: 35 Ton Rental Air Handling Unit...35 Ton Rental Air Handling Unit Unit Features: § Direct drive High Static plenum fan with 10hp TEFC motor § Maximum rated static pressure of 5.6

For more information, contact: 281.540.2805

35TonRentalAirHandlingUnit

UnitFeatures:

§ DirectdriveHighStaticplenumfanwith10hpTEFCmotor§ Maximumratedstaticpressureof5.6in-wg§ Ratedcoolingairflowof5,000cfmwith100%OutsideAir§ Airflowrangeof2000–5,000cfm§ Hydrophiliccoatedfinsforcooling&hotwatercoil§ Stainlesssteelhardware§ StainlessSteeldrainpan§ PermanentlyinstalleddrainpanP-trap(protectedwithinunitbase)

PackageFeatures:

§ PhasemonitorandIncorrectphaseindicatorlight(red)§ CircuitBreakersonallmotors§ BlowerVFDwithinlinestarterandbypassswitch§ SpeedPotentiometerforBlowerVFDtoadjustspeedfrom30Hzto77Hz§ Fulltubularrentalbasewithforkpockets&tie-downpoints

ü Hot-dippedgalvanized§ CoolingunitmayruninVFDorBYPASSmode§ DuctDoorsfactoryinstalledforallsupply/returnconnections§ Quietoperation

OperationProcedure:

STEP1:Confirmthatcircuitbreaker(3CB)isswitchedONandCONTROLPOWERpilotlight(1PL)islit.• Ifnot,checkphasemonitorrelay(PMR)andemergencystop(ES)button.• IfINCORRECTPHASEpilotlight(2PL)islit,checkPMRforphaserotationandvoltagesetting.STEP2:TurnVFD/OFF/BYPswitch(1SW)torequirebloweroperatingmode.• VFDRUNNINGpilotlight(3PL)litifblowerisstartedusingVFD.• BYPASSRUNNINGpilotlight(5PL)litifblowerisstartedusingbypassstarter.• Checkblowercircuitbreakeroverload(1OL)orVFDstatusifBLOWERTRIPpilotlight(4PL)islit.STEP3:SetblowerrunningspeedusingSPDADJPOT(potentiometer)

Itisthecustomer’sresponsibilitytoalwaysfollowthewrittenoperatinginstructionsoftheunitandmaintainsafeworkpractices

Page 3: 35 Ton Rental Air Handling Unit...35 Ton Rental Air Handling Unit Unit Features: § Direct drive High Static plenum fan with 10hp TEFC motor § Maximum rated static pressure of 5.6

For more information, contact: 281.540.2805

35TonRentalAirHandlingUnitBlowerData:60HZcurvebelow.Unitmaybeoperatedabove60HZinVFDmodewithhigherairflow