399800 b ams-8923 connection diagram...ams-8923 connection diagram 399800, rev b a, initial release...
TRANSCRIPT
AMS-8923 Connection Diagram
399800, Rev B A, Initial Release - May, 20101, Custom Design - August, 2007 B, Revised Release - April, 2017Revision / Date: ets-lindgren.com ets-lindgren.com
Note: ETS-Lindgren may substitute a similar part with the same functionality for another part.
Warranty Informationeht ees ,noitamrofni ytnarraw roF Product Information Bulletin.
Product Information Bulletin
:gniwollof eht rof tnempihs ruoy htiw dedulcninergdniL-STEeht eeS Product Information Bulletin
Warranty informationSafety, regulatory, and other product marking informationSteps to receive your shipmentSteps to return a component for serviceETS-Lindgren calibration serviceETS-Lindgren contact information
© Copyright 2007-2017 by ETS-Lindgren Inc. All Rights Reserved. No part of this document may be copiedby any means without written permission from ETS-Lindgren Inc.
The logo is a registered trademark of ETS-Lindgren Inc.ETS-Lindgren
USA Headquarters1301 Arrow Point DriveCedar Park, TX 78613Phone: +1.512.531.6400
Please see ets-lindgren.com for a list of all ETS-Lindgren offices.
WARRANTY
.tnempihs ruoy htiw dedulcnieht ees ,noitamrofni ytefas lanoitidda roF Product Information Bulletin
Safety Information
Laser Danger: Denotes a laser (IEC Class 3B) is part of the operating system of the device. Laser powerrange is 5-500 mW.
Visible laser radiation: Avoid exposure to beam. Do not stare into beam or view directly with optical instruments.
Left Side
Right Side
RightTop
RightBottom
Control Box (part# 114760)•
EMCenter Modular RF PlatformTM•TEST INSTRUM ENT
Test Instrumentation(required units provided by customer)
•
•AMS-8923 installed in finished chamber(part# 114700) • Interconnect Kit (part# 115018)
Laser Control(part# 115017)
Sensor Position Display(part# 115014)
Laser Cable(part# 665080)
4-Conductor Cable (part# 660046)(part# 660047)8-Conductor Cable
(part# 705344-10)Fiber Optic Cable (part# 106043-10m)BNC Cable
• 10-Meter Fiber Optic Cable(part# 705344-10)
Additional cables(as required by configuration)
HIGH VOLTAGE: Indicates presence of hazardous voltage. Unsafe practice could result in severe personal injuryor death.
CONTACT ETS-LINDGREN PRIOR TO SERVICING. Servicing (or modifying) the unit by yourself may void yourwarranty if you attempt to service the unit by yourself, disconnect all electrical power before starting. There are voltages at many points in the instrument that could, if contacted, cause personal injury. Only trained servicepersonnel should perform adjustments and/or service procedures upon this instrument. Capacitors inside this instrument may still be CHARGED even when instrument is disconnected from its power source.
BEFORE POWER IS APPLIED TO THIS INSTRUMENT, GROUND IT PROPERLY through the protective conductor of the AC power cable to a power source provided with protective earth contact. Any interruption of the protective (grounding) conductor, inside or outside the instrument, or disconnection of the protective earth terminal could result in personal injury.
These components are required to connect the AMS-8923 Measurement System:
+105
+90
+75
+60
+45
+30
+15
0
PHI
-15
-30
-45
-60
-75
-90
-105
-120
PHI
THETA
+105
+90
+75
+60
+45
+30
+15
0
THETA
-15
-30
-45
-60
-75
-90
-105
-120
-135
-150
-165
+165
+150
+135
+120
PHI
-135
-150
-165
+165
+150
+135
+120
THETA
RF PORTS
100/240 VAC50/60 Hz
100 VA M AX
HI G H VO LTAG E
WARNI NG
AMS–8923 Controller Box Part #114760
LASER LASERSWITCH DISPLAY
THETA PHIDEDICATED PATHS SWITCHED
PATH
TRIGGEROUTPUT
™
Laser On
Power On EMCenter
Interlock
Standby
OFF
ON
ALIGNM ENT LASERS
part#705344-10
part# 660047
part# 660046AMS-8923 Connection Diagram
ets-lindgren.com
Before connecting any components, see on the back page of this document.Safety Information
part# 665080
Theta switch assembly
Phi switch assembly
Controller Box - Right Side, Bottom
Controller Box - Left Side
Controller Box - Right Side, Top
Connect Phi and Thetaswitch assemblies
from each sensor toappropriate connectors
on Controller Box
+105
+90
+75
+60
+45
+30
+15
0
PHI
THETA
+105
+90
+75
+60
+45
+30
+15
0
+105
+90
+75
+60
+45
+30
+15
0
PHI
-15
-30
-45
-60
-75
-90
-105
-120
PHI
THETA
+105
+90
+75
+60
+45
+30
+15
0
THETA
-15
-30
-45
-60
-75
-90
-105
-120
-135
-150
-165
+165
+150
+135
+120
PHI
-135
-150
-165
+165
+150
+135
+120
THETA
RF PORTS
LASERSWITCH
DISPLAY
100/240 VAC50/60 Hz
100 VA M AX
HI G H VO LTAG E
WARNI NG
AMS–8923 Controller Box Part #114760
LASER
TRIGGEROUTPUT
part# 660046
part# 660047 Filter
RF PORTS
THETA PHI
SWITCHEDPATH
DEDICATED PATHS
LASER
part# 705344-10
OUT
IN
TEST INSTRUM ENT
TEST INSTRUM ENT
Equipment Rack
EMCenter
part# 106043-10m
LASERSWITCH DISPLAY
THETA PHIDEDICATED PATHS SWITCHED
PATH
OFF
ON
ALIGNM ENT LASERS
EMControl7006-001
TM
EMControl7006-001
TM
1 2AUXILIARY
DEVICE 1OUT
DEVICE 2IN OUT
IN
1 2AUXILIARY
DEVICE 1IN OUT
DEVICE 2IN OUT