TM ITA2 UPS 5-20kVA Compact, Efficient & Robust UPS For Critical Applications

Upload: phungthuan

Post on 15-Jun-2018

226 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

TMITA2 UPS

5-20kVACompact, Efficient & Robust UPSFor Critical Applications

Page 2: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

WE ARE VERTIV

VertivYour Vision, our Passion

Vertiv, formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications for data centers, communication networks, and commercial & industrial environments.

We support today's growing mobile and cloud computing markets with our portfolio of power, thermal and infrastructure management products, software and solutions, all complemented by our extensive global service network.

We help strengthen the world's most vital applications by bringing together global reach and local knowledge, and our decades-long heritage, including brands like Chloride, Liebert, NetSure, and Trellis.

With a unique combination of industry expertise, technology, and resources, our mission is to support and power mission-critical technologies that drive possibility.

Co & ne suci ltv ar te ioS ntwaf ro eS

franI s td re uif ci tn urU e

ThermalManagement

PowerManagement

IT Management

Our industry-leading software gives customers an integrated view of operations across IT and facilities resources, enabling better decisions that save time and money

Our global power and thermal management solutions are some of the world’s most e�icient and reliable power and cooling technologies

Our global industrial power solutions meet the most demanding technical specifications and provide safe, reliable power- no matter the challenge

Our global intelligently engineered DC power systems deliver high availability, energy e�iciency and scalability for converged networks

Page 3: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

In today's dynamic world, it is not enough for enterprises to have basic power protection. With digital trends constantly emerging and transforming the way you do business, business continuity is all the more vital. You simply cannot afford downtime in your critical system or waste time recovering these systems after a disruption. What you need is a robust, high-speed, reliable UPS system, which offers

perennial, round-the-clock protection to diverse application needs.

TMThe Liebert® ITA2 is a fully-digital, highly reliable, double-conversion UPS solution that delivers clean and consistent power.

This highly efficient solution is ideal for various deployments, whether it's IT racks, network closets, automation control systems, and precision instruments to small-sized control rooms among other edge applications.

Ÿ Cutting –edge design enables seamless integration into various ecosystems

Ÿ Tailored for global deployment in a low carbon, compact footprint

The ultimate level of engineering and dynamics that have gone beyond the development of this next-generation, innovative product facilitate top-notch availability and excellent performance at a low cost of ownership, giving you ultimate peace of mind.

Our Solution

Application Areas

5-10kVA

16-20kVA

TM ®Liebert ITA2 5-20kVA

Ÿ Edge Networks

Ÿ Data Centers

Ÿ Automation industries

Ÿ Server Farms

Ÿ Workstations

Ÿ Telecom1

Ÿ Marine

TMLiebert® ITA2

Page 4: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

TM Liebert ITA2 5-20kVA

Key Features

Ÿ Robust structure with cutting-edge channelized airflow design

Ÿ Wide input voltage range, making it immune to grid interference

Ÿ Programmable output outlets/ terminals with cascade protection to protect key devices during heavy load

Ÿ Integrated Ethernet port with HTTP protocol compatibility & streamlined remote monitoring

Ÿ Easy to install, repair, and maintain

Ÿ Compliance with seismic conduction & vehicle carrying test

Ÿ Gravity sense LCD Display

Ÿ Turnkey Dust-proof design with ability to operate under high ambient temperature of up to

o50 C

TM ® Liebert ITA2 offers best-in-class efficiency of up to 96.3% over a wide range of load conditions, resulting in significant OPEX cost savings.

TMITA2 's integrated Smart Sleep technology in ECO mode provides a superlative efficiency of up to 99%.

70605040

3020

100

2Sp

ace/

inch

®Liebert ITA2 Brand A Brand B

The Most Efficient UPS

The Most Compact UPS

Load(%)

Effi

cien

cy(%

)

Page 5: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

TM ®Available in different wattage variations, Liebert ITA2is ideal in edge of networks, light industrial applications and data centers, blending easily into any virtualized environment and providing comprehensive power protection at lower operating costs.

Reliability in a Compact Footprint:

Ÿ Fully-digital control with high output voltage precision.

Ÿ Manages all the nine power problems including sagging, spikes, and fluctuations.

Ÿ Built-in Ethernet port includes compatibility with intelligent cards (SIC card, RDU_SIC cards, etc.,) with browser support.

Ÿ Built-in-power charger for fast charging reduces battery charging time.

Ÿ Prolonged backup time through cascaded connection.

Ÿ Quality-tested for 1000 hours for extreme durability and extreme tolerance even in stringent condition

High Availability

Early Warning of UPS System Status: Multiple audible and visual alarms immediately alert you to critical issues.

Periodic Battery TestingProvides automatic and manual self-diagnostic battery testing for peace of mind.

Power-Factor CorrectionPrevents noise, harmonics, and distortion from being passed on to connected loads or from being fed back to the utility.

Lightning and Surge ProtectionThe transient voltage surge suppression circuitry inside

TM ®the Liebert ITA2 provides additional protection for the connected equipment.

Wide Input Voltage WindowProlongs battery life by allowing the UPS to maximize the use of utility power before transferring to the battery when the input voltage exceeds the specified limits.

Dust-Proof Design

Page 6: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

Model

Model

Model

Model

Battery Backup Table

Model Number

Model Number

Model Number

Model Number

Backup Time

Backup Time

Backup Time

Backup Time

5kVA

10kVA

16kVA

20kVA

4.5kVA

9kVA

14.4kVA

18kVA

4kVA

8kVA

12.8kVA

16kVA

3.5kVA

7kVA

11.2kVA

14kVA

3kVA

6kVA

9.6kVA

12kVA

2.5kVA

5kVA

8kVA

10kVA

2kVA

4kVA

6.4kVA

8kVA

1.5kVA

3kVA

4.8kVA

6kVA

1kVA

2kVA

3.2kVA

4kVA

0.5kVA

1kVA

1.6kVA

2kVA

5kVA

10kVA

16kVA

20kVA

123456

23456

4681012

4681012

5.515.027.039.551.563.5

4.08.012.518.023.5

7.514.021.028.535.5

5.510.015.021.027.0

6.517.531.045.058.071.5

4.59.515.021.027.0

9.016.024.533.041.5

6.511.517.524.531.5

7.520.536.051.566.581.5

6.011.518.025.032.0

10.519.028.538.548.0

7.514.021.028.536.5

9.525.042.560.077.094.5

8.014.522.030.038.5

13.024.534.045.556.0

9.517.025.534.043.0

11.530.551.071.591.5111.5

11.521.031.041.551.5

16.028.541.554.567.0

11.521.031.041.552.0

15.039.063.087.0111.5139.5

15.027.039.551.563.5

21.036.552.067.082.0

15.027.039.552.064.0

20.551.080.5104.0146.0181.5

20.536.051.566.581.5

28.548.067.086.0105.0

21.036.552.067.082.0

30.070.0110.0156.5203.5250.5

30.551.071.591.5111.5

41.566.592.0118.5148.5

31.051.572.092.5112.5

49.5108.0177.0246.5316.0386.0

51.080.5110.5146.0181.5

145.0233.5322.0410.5498.5

51.581.5112.0148.0184.0

103.5235.0368.5502.0635.5768.5

108.0177.0246.5316.0386.0

108.0177.0246.5316.0386.0

111.0181.5252.5324.0395.0

POD-Optional Accessories

When your critical system can not afford any power loss without power, even for scheduled UPS maintenance, the Liebert POD Maintenance Bypass and Output Distribution Unit ensures continuous uptime.

It allows you to manually transfer connected equipment to utility power via a maintenancebypass switch, permitting scheduled service or UPS replacement without the need to shut down connected equipment.

Features include:

Ÿ 2U height minimizes rack space requirements

Ÿ Easy plug-and-play installation

POD

ITA2 UPS

Battery module

Isometric view of Liebert ITA2 UPS installed in a rack-mounted alignment along with POD and Battery modules

Page 7: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

Input frequency range(Hz)

Nominal output frequency (Hz)

Voltage harmonic distortion(%)

Crestfactor

Overload capacity

Rated power factor(kW/kVA)

Nominal output voltage (V)

Battery Charger max. power (A)

5

Nominal input frequency(Hz)

DC Bus Voltage

Nominal Ratings(kVA)

Dimensions and weight

Nosie at 1 m(dBA)

Dimensions (W x D x H) in mmRack Mounted Arrangement

220/230/240VAC1-Phase, 2Wire

220/230/240VAC 1-Phase, 2Wire380/400/415VAC 3-Phase,4Wire

380/400/415VAC 3-Phase,4Wire

Input voltage range(V)

Nominal input voltage(V)

UPS classification according toIEC 62040-3

General and safety requirements for UPS

10 16

Input power factor(kW/kVA)*

Current THD at full linear load(THDi%)*

Input parameters

Weight(kg)

General

176-288VAC at full load; 100-176VAC at linear derating; 100VAC at half load

50/60

40-70

0.99

140-240VDC

= 5A (Long back-up model)

= 2A (Standard model)

= 8A (Long back-up model)

= 4A (Standard model)

= 13A (Long back-up model)

= 5A (Standard model)

140-240VDC 288-480VDC

<5

220/230/240 (1-phase) 220/230/240VAC (1-Phase), 380/400/415VAC (3-Phase)

50/60

Unity

<2% for Linear loads & <5% for Non-linear loads

3:1

At 25°C: 105% ~ 125%, 5min; 125% ~ 150%, 1min; 150%, 200ms

Up to 95.8% Up to 96.2%Up to 95.5%

Up to 99%

430x400x85 430x500x85 430x500x130

IEC/EN 62040-1

VFI-SS-111

Operating temperature(°C)

Altitude(m)

Relative humidity (%RH)

0 ~ 50*

=3000m

5 ~ 95, non-condensing

Battery

Output

EMC requirements for UPS IEC/EN 62040-2

* Conditions apply(1) with ABS certification

Technical Specifications

Online mode efficiency

ECO mode efficiency

Efficiency

11 15 23

=58=55

Battery Option P/C : ITA-BCI0020K01 ( built-in battery module of 16 block X 12V X 9AH)

6 20

ITA-05k00AL1102P00/ITA-05k00AE1102P00Standard/Long Backup Model ITA-06k00AL1102P00/

ITA-06k00AE1102P00ITA-10k00ALA102P00/ITA-10k00AEA102P00

ITA-16k00AL3A02P00/ITA-16k00AE3A02P00

ITA-20k00AL3A02P00/ITA-20k00AE3A02P00

Note: Specification are subject to change without any further notification

Page 8: 5-20kVA Compact, Efficient & Robust UPS For Critical ... formerly Emerson Network Power, designs, builds, and services mission critical technologies that enable vital applications

© 2017 Vertiv Co. All rights reserved. Vertiv and the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.

AP-UPS-ITA-V2-1217-EN

Asia Pacific

Renata Annakin