5715 - pr electronics series... · 2020-02-03 · vores motto »signals the best« er indbegrebet...

24
5715 Programmable LED Indicator No. 5715V102-UK From serial number: 121496001 (B) 131077001 (D)

Upload: others

Post on 17-Feb-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5 7 1 5P r o g r a m m a b l eL E D I n d i c a t o r

N o . 5 7 1 5 V 1 0 2 - U KF r o m s e r i a l n u m b e r :1 2 1 4 9 6 0 0 1 ( B )1 3 1 0 7 7 0 0 1 ( D )

Page 2: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

1651

PR electronics A/S tilbyder et bredt program af analoge og digitale signalbehandlingsmoduler til industriel automation. Programmet består af Isolatorer, Displays, Ex-barrierer, Temperaturtransmittere, Universaltransmittere mfl. Vi har modulerne, du kan stole på i selv barske miljøer med elektrisk støj, vibrationer og temperaturudsving, og alle produkter opfylder de strengeste internationale standarder. Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet.

PR electronics A/S offers a wide range of analog and digital signal conditioning devices for industrial automation. The product range includes Isolators, Displays, Ex Interfaces, Temperature Transmitters, and Universal Devices. You can trust our products in the most extreme environments with electrical noise, vibrations and temperature fluctuations, and all products comply with the most exacting international standards. »Signals the Best« is the epitome of our philosophy – and your guarantee for quality.

PR electronics A/S offre une large gamme de produits pour le traite ment des signaux analogiques et numériques dans tous les domaines industriels. La gamme de produits s’étend des transmetteurs de température aux afficheurs, des isolateurs aux interfaces SI, jusqu’aux modules universels. Vous pouvez compter sur nos produits même dans les conditions d’utilisation sévères, p.ex. bruit électrique, vibrations et fluctuations de température. Tous nos produits sont conformes aux normes internationales les plus strictes. Notre devise »SIGNALS the BEST« c’est notre ligne de conduite - et pour vous l’assurance de la meilleure qualité.

PR electronics A/S verfügt über ein breites Produktprogramm an analogen und digitalen Signalverarbeitungsgeräte für die in-dustrielle Automatisierung. Dieses Programm umfasst Displays, Temperaturtransmitter, Ex- und galvanische Signaltrenner, und Universalgeräte. Sie können unsere Geräte auch unter extremen Einsatzbedingungen wie elektrisches Rauschen, Erschütterungen und Temperaturschwingungen vertrauen, und alle Produkte von PR electronics werden in Überein stimmung mit den strengsten internationalen Normen produziert. »Signals the Best« ist Ihre Garantie für Qualität!

DK

UK

FR

DE

Page 3: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 3

PROGRAMMABLE LED INDICATOR

5715

CONTENTS

Warning ....................................................................................................... 4Symbol identification ............................................................................ 4Safety instructions ................................................................................. 5Front and back layout ........................................................................... 7Application ................................................................................................. 8Technical characteristics ...................................................................... 8Mounting / installation ......................................................................... 8Applications............................................................................................... 9Order: 5715 ............................................................................................... 10Electrical specifications........................................................................ 10Sensor error detection inside and outside range ...................... 14Connections .............................................................................................. 15Block diagram ........................................................................................... 16Routing diagram ...................................................................................... 18Scrolling help texts ................................................................................ 19Configuration / operating the function keys ............................... 21Programming via PC............................................................................... 22Graphic depiction of the relay function setpoint....................... 22

Page 4: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

4 5715V102-UK

SYMBOL IDENTIFICATION

Triangle with an exclamation mark: Warning / demand. Potentially lethal situations. The CE mark proves the compliance of the module with the essential requirements of the directives.

WARNINGThis module is designed for connection to hazardous electric vol-tages. Ignoring this warning can result in severe personal injury or mechanical damage. To avoid the risk of electric shock and fire, the safety instructions of this manual must be observed and the guidelines followed. The specifications must not be exceeded, and the module must only be applied as described in the follo-wing. Prior to the commissioning of the module, this manual must be examined carefully. Only qualified personnel (technicians) should install this module. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired.

WARNINGUntil the module is fixed, do not connect hazardous voltages to the module.The following operations should only be carried out on a discon-nected module and under ESD safe conditions: Troubleshooting the module.

Repair of the module must be done by PR electronics A/S only.

HAZARD OUS VOLTAGE

GENERAL

Page 5: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 5

SAFETY INSTRUCTIONS

DEFINITIONSHazardous voltages have been defined as the ranges: 75 to 1500 Volt DC, and 50 to 1000 Volt AC.Technicians are qualified persons educated or trained to mount, operate, and also troubleshoot technically correct and in accordance with safety regulations.Operators, being familiar with the contents of this manual, adjust and operate the knobs or potentiometers during normal operation.

RECEIPT AND UNPACKINGUnpack the device without damaging it. The packing should always follow the device until this has been permanently mounted. Check at the receipt of the device whether the type corresponds to the one ordered.

ENVIRONMENTAvoid direct sunlight, dust, high temperatures, mechanical vibrations and shock, as well as rain and heavy moisture. If necessary, heating in excess of the stated limits for ambient temperatures should be avoided by way of ventilation.All modules fall under Installation Category II, Pollution Degree 1, and Insulation Class II.

MOUNTINGOnly technicians who are familiar with the technical terms, warnings, and instruc-tions in the manual and who are able to follow these should connect the module. Should there be any doubt as to the correct handling of the module, please con-tact your local distributor or, alternatively,

PR electronics A/Swww.prelectronics.com

Mounting and connection of the module should comply with national legislation for mounting of electric materials, i.e. wire cross section, protective fuse, and location. Descriptions of Input / Output and supply connections are shown in the block diagram and side label.

Page 6: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

6 5715V102-UK

The following apply to fixed hazardous voltages-connected modules:The max. size of the protective fuse is 10 A and, together with a power switch, it should be easily accessible and close to the module. The power switch should be marked with a label telling it will switch off the voltage to the module.

UL INSTALLATION REQUIREMENTSFor use on a flat surface of a type 1 enclosure Use 60/75°C copper conducters only Enclosure rating (face only)........................... Type 4X, UL50E Max. ambient temperature ............................ 60°C Max. wire size, pins 41...46 ........................... AWG 30-16 Max. wire size, others ...................................... AWG 30-12 UL file number .................................................... E248256

CALIBRATION AND ADJUSTMENTDuring calibration and adjustment, the measuring and connection of external voltages must be carried out according to the specifications of this manual. The technician must use tools and instruments that are safe to use.

NORMAL OPERATIONOperators are only allowed to adjust and operate modules that are safely fixed in panels, etc., thus avoiding the danger of personal injury and damage. This means there is no electrical shock hazard, and the module is easily accessible.

CLEANINGWhen disconnected, the module may be cleaned with a cloth moistened with distilled water.

LIABILITYTo the extent the instructions in this manual are not strictly observed, the custom er cannot advance a demand against PR electronics A/S that would other-wise exist according to the concluded sales agreement.

Page 7: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 7

FRONT AND BACK LAYOUT

Picure 1: Front of PReview 5715.

Picture 2: Back of PReview 5715.

Page 8: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

8 5715V102-UK

PROGRAMMABLE LED INDICATOR PREVIEW 5715

• 4-digit 14-segment LED display • Input for mA, V, potentiometer, Ohm, RTD and TC • 4 relays and analogue output • Universal supply • Programmable via front keys and PC

Application• Display for digital readout of current / voltage / resistance / temperature or

3-wire potentiometer signals.

• Process control with 4 pairs of potential-free change-over relays and analogue output.

• For tank level control, with the possibility of customer linearisation ensuring correct level measurement and control in non-linear tanks.

Technical characteristics• 4-digit LED indicator with 13.8 mm 14-segment characters. Max. display

read out -1999...9999 with programmable decimal point and relay ON / OFF indication.

• All standard operational parameters can be adjusted to any application by way of the front function keys. When programming is carried out by way of a PC and the configuration program PReset, additional configuration options are available, such as customer-defined linearisation and special input signals.

• Help texts in eight languages can be selected via a menu item.

• A menu item allows the user to minimise the installation test time for the relay outputs by activating / deactivating each relay independently of the input signal.

Mounting / installation• To be mounted in panel front. The included rubber packing must be mounted

between the panel cutout hole and the display front to obtain a protection degree of IP65 (type 4X). For extra protection in extreme environments, PReview 5715 can be delivered with a specially designed splash-proof cover as accessory.

Page 9: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

46

45

44

43

42

41

4 3 2

1 2 3 4

1 2 3 4 12

11

26

25

24

23

22

21

66

65

64

63

62

61

32

31

1 2 3 4

-

+

-

+

-

+

-

+

-

+

5715V102-UK 9

APPLICATIONS

Input signals:Current

Potentio-meter

Output signals:

4 change-over relaysAnalogue, 0/4...20 mA

Supply:

21.6...253 VAC or

19.2...300 VDC

Voltage

RTD & Lin R -Connection, wires

2-t

wire

tra

nsm

itte

r

TC

Page 10: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

10 5715V102-UK

Electrical specificationsSpecifications range:-20°C to +60°CCommon specifications:Supply voltage, universal ..................................... 21.6...253 VAC, 50...60 Hz or 19.2...300 VDCConsumption:

Isolation voltage, test / operation .................... 2.3 kVAC / 250 VAC Signal / noise ratio .................................................. Min. 60 dB (0...100 kHz) Communications interface ................................... USB Loop Link Response time (0...90%, 100...10%): Temperature input .............................................. < 1 s Current / voltage input ..................................... < 400 ms Calibration temperature ........................................ 20...28°C Accuracy, the greater of general and basic values:

General values

Input type

Absolute accucary

Temperature coefficient

All ≤ ±0.1% of reading ≤ ±0.01% of reading / °C

Type Internal consumption Max. consumption

5715B 3.0 W 3.3 W

5715D 3.5 W 3.8 W

Type Version

5715 4 relays. . . . . . . . . . . . . . . . . . . . . . . . : B Analogue output and 4 relays . . . : D

Order: 5715

Page 11: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 11

Auxiliary supply: 2-wire supply (pin 46...45) .............................. 25...15 VDC / 0...20 mA / 30 mA nom. Vibration ...................................................................... IEC 60068-2-6 Test FC 2...13.2 Hz .............................................................. ±1 mm 13.2...100 Hz ........................................................ ±0.7 g Wire size, pin 41...46 (max.) ................................ 1 x 1.5 mm2 stranded wire Wire size, others (max.) ......................................... 1 x 2.5 mm2 stranded wire Relative humidity..................................................... < 95% RH (non cond.) Dimensions (HxBxD) ............................................... 48 x 96 x 120 mm Cutout dimensions .................................................. 44.5 x 91.5 mm Protection degree (mounted in panel) ............ IP65 / Type 4X, UL50E Weight .......................................................................... 260 gRTD, linear resistance and potentiometer input:

EMC immunity influence .................................................. < ±0,5% of reading

Basic valuesInput type

Basic accuracy

Temperature coefficient

mA ≤ ±4 µA ≤ ±0.4 µA / °CVolt ≤ ±20 µV ≤ ±2 µV / °C

Pt100 ≤ ±0.2°C ≤ ±0.01°C / °CLinear resistance ≤ ±0.1 Ω ≤ ±0.01 Ω / °C

Potentiometer ≤ ±0.1 Ω ≤ ±0.01 Ω / °CTC type:

E, J, K, L, N, T, U

≤ ±1°C

≤ ±0.05°C / °CTC type: R, S, W3,

W5, LR

≤ ±2°C

≤ ±0.2°C / °CTC type: B 85...200°C

≤ ±4°C

≤ ±0.4°C / °C

TC type: B 200...1820°C

≤ ±2°C

≤ ±0.2°C / °C

Input type

Min. value

Max. value

Standard

Pt10...Pt1000 Ni50...Ni1000 Cu10...Cu100

Lin. R Potentiometer

-200°C -60°C

-200°C 0 Ω

10 Ω

+850°C +250°C +260°C

10000 Ω 100 kΩ

IEC 60751 DIN 43760

α = 0.00427 - -

Page 12: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

12 5715V102-UK

Input for RTD types: Pt10, Pt20, Pt50, Pt100, Pt200, Pt250, Pt300, Pt400, Pt500, Pt1000 Ni50, Ni100, Ni120, Ni1000, Cu10, Cu20, Cu50, Cu100Cable resistance per wire, RTD (max.)............. 50 Ω Sensor current, RTD ................................................ Nom. 0.2 mA Effect of sensor cable resistance (3- / 4-wire), RTD ..................................................... < 0.002 Ω / Ω Sensor error detection, RTD ................................ Yes Short circuit detection, RTD ................................ < 15 ΩTC input:

Cold junction compensation (CJC) via internal sensor ............................................. ±(2.0°C + 0.4°C * Δt)Δt = internal temperature - ambient temperature Sensor error detection, all TC types................. Yes Sensor error current: when detecting ................................................... Nom. 2 μA else .......................................................................... 0 μACurrent input:Measurement range ................................................ 0...20 mA Programmable measurement ranges ............... 0...20 and 4...20 mAInput resistance........................................................ Nom. 20 Ω + PTC 25 Ω Sensor error detection: loop break 4...20 mA .......................................... Yes

Type

Min. value

Max. value

Standard

B E J K L N R S T U

W3 W5 LR

+0°C -100°C -100°C -180°C -200°C -180°C -50°C -50°C

-200°C -200°C

0°C 0°C

-200°C

+1820°C +1000°C +1200°C +1372°C +900°C

+1300°C +1760°C +1760°C +400°C +600°C

+2300°C +2300°C +800°C

IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1 DIN 43710

IEC 60584-1 IEC 60584-1 IEC 60584-1 IEC 60584-1 DIN 43710

ASTM E988-90 ASTM E988-90 GOST 3044-84

Page 13: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 13

Voltage input:Measurement range ................................................ 0...12 VDC Programmable measurement ranges ............... 0...1, 0.2...1, 0...10 and 2...10 VDCInput resistance........................................................ Nom. 10 MΩOutputs:Display:Display readout......................................................... -1999...9999 (4 digits) Decimal point ............................................................. Programmable Digit height ................................................................ 13.8 mm Display updating ...................................................... 2.2 times / s Input outside input range is indicated by................................................................ Explanatory textCurrent output:Signal range (span) ................................................. 0...20 mA Programmable signal ranges ............................... 0...20, 4...20, 20...0 and 20...4 mALoad (max.) ................................................................. 20 mA / 800 Ω / 16 VDC Load stability ............................................................. ≤ 0.01% of span / 100 Ω Sensor error detection ........................................... 23 / 0 / 3.5 mA / none NAMUR NE 43 Up- / Downscale ........................ 23 mA / 3.5 mA Output limitation: on 4...20 and 20...4 mA signals ..................... 3,8...20.5 mA on 0...20 and 20...0 mA signals ..................... 0...20.5 mA Current limit ............................................................... ≤ 28 mARelay outputs:Relay function ........................................................... SetpointHysteresis ................................................................... 0...100% On and Off delay ...................................................... 0...3600 s Sensor error detection ........................................... Make / Break / Hold Max. voltage .............................................................. 250 VRMS Max. current ............................................................... 2 A / AC Max. AC power .......................................................... 500 VA Max. current at 24 VDC ......................................... 1 AMarine approval:Det Norske Veritas, Ships & Offshore ............. Standard for Certification No. 2.4Observed authority requirements: Standard:EMC 2004/108/EC .................................................. EN 61326-1LVD 2006/95/EC ...................................................... EN 61010-1UL, Standard for Safety ......................................... UL 508 EAC TR-CU 020/2011 ............................................ EN 61326-1

Page 14: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

14 5715V102-UK

Sensor error detection inside and outside rangeSensor error check in 5715 variants:

Variant: Configuration Sensor error detection:

5715BERR1, ERR2, ERR3 and ERR4 = NONE OFF

Else: ON

5715DERR1, ERR2, ERR3 and ERR4=NONE, O.ERR=NONE. OFF

Else: ON

Readout at hardware error ! Error indications in the display blink once a second. The help text explains the error

Error search Readout Error causeTest of internal communication uC / ADC HW.ER Permanent error in ADCTest of internal CJC sensor CJ.ER CJC sensor defectCheck-sum test of the configuration in RAM RA.ER Error in RAMCheck-sum test of the configuration in EEprom EE.ER Error in EEPROM

Outside range readout (IN.LO, IN.HI): If the valid range of the A/D converter or the polynomial is exceeded

Input Range Readout Limit

VOLT0...1 V / 0,2...1 V

IN.LO < -25 mVIN.HI > 1,2 V

0...10 V / 2...10 VIN.LO < -25 mVIN.HI > 12 V

CURR 0...20 mA / 4...20 mAIN.LO < -1,05 mAIN.HI > 25,05 mA

POTM -IN.LO < -0,5%IN.HI > 100,5%

TEMP TC / RTDIN.LO < temperature range -2°CIN.HI > temperature range +2°C

LIN R0...800 ohm

IN.LO < 0 ohmIN.HI > 1 kohm

0...10 kohmIN.LO < 0 ohmIN.HI > 15 kohm

Sensor error detection (SE.BR, SE.SH):

Input Range Readout LimitCURR Loop break (4..20mA) SE.BR <= 3,6 mA; > = 21 mA

TEMPTC SE.BR > ca. 750 kohm / (1,25 V)

RTD, 2-, 3- & 4-wire No SE.SH for Cuxx, Pt10, Pt20 & Pt50

SE.BR > 12 kohmSE.SH < 15 ohm

LIN R0...800 ohm SE.BR > 875 ohm0...10 kohm SE.BR > 12 kohm

Display readout below min. / above max. (-1.9.9.9, 9.9.9.9):

Input Range Readout LimitCURR /

VOLT / Lin RAll

-1.9.9.9 Display readout <-19999.9.9.9 Display readout >9999

POTM --1.9.9.9 Display readout <-19999.9.9.9 Display readout >9999

Page 15: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

Tx

31 32

41 42 43 44 45 4641 42 43 44 45 4641 42 43 44 45 46

41 42 43 44 45 46 41 42 43 44 45 46 41 42 43 44 45 46

41 42 43 44 45 46 41 42 43 44 45 46

mA

11 12

R2R1

21 22 23 24 25 26

R3 R4

61 62 63 64 65 66

- +

- +

- + - + - +

5715V102-UK 15

CONNECTIONS

RTD & Lin R, 2-wire RTD & Lin R, 3-wire RTD & Lin R, 4-wire

PotentiometerVoltage

TC 2-wire transmitter Current

Current Relays

Inputs:

Output:

Supply:

Relays

Page 16: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

I+

21

22

23

11

12

31

32

24

25

26

61

62

63

64

65

66

CPU

AD

EEPR

OM

PTC 20

Ω

57

15

12

34

46

45

44

43

42

41

TC+

V

43

2

R1

R2

R3

R4

13

2

Tx+ +

+

mA

16 5715V102-UK

BLOCK DIAGRAM

I O

utpu

tCo

mm

onR

elay

1 N

.O.

Rel

ay 1

N.C

.

Com

mon

Rel

ay 2

N.O

.

Rel

ay 2

N.C

.

Com

mon

Rel

ay 3

N.O

.

Rel

ay 3

N.C

.

Com

mon

Rel

ay 4

N.O

.

Rel

ay 4

N.C

.

Supp

ly

Supp

ly

21

.6...

25

3 V

AC

or1

9.2

...3

00

VD

C

Vers

ion

D

0.2

mA

Int.

CJ

C

2-w

ire s

uppl

y>

15

VD

C

Inpu

t +

, m

A

Inpu

t gn

d.

RTD

& L

in R

w

ires

Potm

.

PC c

omm

unic

atio

n

Gnd

.

Page 17: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

C.LIN1.4

DEC.P

Power up

50.0

3

F.SET

REL1

REL2

REL3

REL4

3

1.0

1.21 2

1 2

SETP

-1999

9999

/OFF 3

1 2

DI.LO PERCDI.HI

1.1

0000

9999

1 2

3

CURR 3 RANG

0-20 4-20

1 2

VOLT 3 RANG1 2

0-1 0.2-1

0-10 2-10

IN1 2

1111

1.1.1.1

1 2

POTM

TEMP TYPE

PASS

3a999

9999

1 2

3a999

9999

1 2

3PERC

DISP

1 2

3

1.3

DEC.P

1111

111.1

1 2

UNIT

'C

'F

1 2

ADV

NO

YES

1 2

3

3

LIN.R 3 LR.LO

0-9998

1 2

LR.HI

1-9999

1 2

CONN1 2

2W 3W 4W

3

3

3

CU.TY CONNCU 31 2 1 2

10-100 2W 3W 4W

3

3

1 2

3

3 3 3

3

ADV.SET

YES

3

PT.TY

TC

CONN

TC.TY

PT 31 2 1 2

NI NI.TY CONN

50-1000

1 2

2W 3W 4W

1 2

1 2

3

3

3

TC.B-E-J-K-L-N-R

S-T-U-W3-W5-LR

10-1000 2W 3W 4W

33

3

3

5715V102-UK 17

1.0 = Default state1.1 = Only if password-protected1.2 = Only is FastSet is enabled1.3 = Setpoint adjustment and

relay test disabled at pass-word 5000...9999.

1.4 = Only for special configuration via PC

1.5 = Not valid for these input signals: Potentiometer, 0...20 mA and voltage

1.6 = Only if input signal is tem-perature

1.7 = No analogue output1.8 = In default state press and

hold 1 or 2 to change display intensity between damped and full (7 = full intensity)

Fast setpoint adjustment and relay test

1Increase setpoint 2Decrease setpoint 3Save and exit the menu 1and 2 simultaneously = relay changes state

Page 18: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

3

REL.1

SET

SKIP

OFF

1 2

3

SETP

0.0

100.0

1 2

3

ACT1

INCR

DECR

1 2

3

HYS1

0.0

100.0

1 2

3

ERR1

HOLD

ACTI

DEAC

NONE

1 2

3

ON.DE

0000

3600

1 2

3

OF.DE

0000

3600

1 2

33

1.5

REL.X

SET

SKIP

OFF

1 2

3

SETP

0.0

100.0

1 2

3

ACTX

INCR

DECR

1 2

3

HYSX

0.0

100.0

1 2

3

ERRX

HOLD

ACTI

DEAC

NONE

1 2

3

ON.DE

0000

3600

1 2

3

OF.DE

0000

3600

1 2

33

1.5

A.OUT

4-20

0-20

20-4

20-0

1 2

3

O.LO

a999

9999

1 2

3

O.HI

a999

9999

1 2

3

O.ERR

0/3.5mA

23mA

NONE

1 2

3

RESP

0.0

60.0

1 2

3

E.PAS

YES

NO

1 2

3

N.PAS

0000

9999

1 2

3

NO

----

1.51.6 1.6

1.7 1.7

DE DK

ES FR

IT SE

UK CZ

X = 2...4

ADV.SET

LANG

DISP

CAL

1.8 7LIGH

3

1...7

12

LANG DISP CAL 12

3

3 UKHLP.T

12

3 YESCA.LO

3

YES NO

12

2.0VAL.L

3

100.0 0.0

12

NO

3

YESCA.HI

3

12

90.0VAL.H

3

100.0 0.0

12

NO

YESUSE.C

3

12

YES NO YES NO

18 5715V102-UK

ROUTING DIAGRAMIf no key is activated for 2 minutes, the display returns to default state 1.0 without saving configuration changes.1 Increase value / choose next parameter 2 Decrease value / choose previous parameter 3 Accept the chosen parameter and go to the next menu Hold 3 Back to previous menu / return to default state 1.0 without saving

To default state 1.0

Page 19: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 19

SCROLLING HELP TEXTSDisplay in default state xxxx, hardware error: SE.BR --> SENSOR WIRE BREAKAGE SE.SH --> SENSOR SHORT CIRCUIT IN.HI --> INPUT OVERRANGE IN.LO --> INPUT UNDERRANGE 9.9.9.9 --> DISPLAY OVERRANGE -1.9.9.9 --> DISPLAY UNDERRANGE HW.ER --> HARDWARE ERROR EE.ER --> EEPROM ERROR - CHECK CONFIGURATION RA.ER --> RAM MEMORY ERROR CJ.ER --> CJC SENSOR ERROR Fastset (Enabled): F.SET REL1 --> FAST SET MENU - REL2 --> SELECT RELAY REL3 REL4 SETP xxxx --> RELAY SETPOINT - PRESS OK TO SAVE Fastset (Disabled): SETP xxxx --> RELAY SETPOINT - READ ONLY Configuration menus: ADV YES --> ENTER ADVANCED SETUP MENU? NO PASS xxxx --> SET CORRECT PASSWORD IN C.LIN* --> TEXT ENTERED BY USER IN PRESET CURR --> CURRENT INPUT VOLT --> VOLTAGE INPUT POTM --> POTENTIOMETER INPUT LIN.R --> LINEAR RESISTANCE INPUT TEMP --> TEMPERATURE SENSOR INPUT RANG When current selected: 0-20 --> INPUT RANGE IN mA 4-20 --> INPUT RANGE IN mA RANG When voltage selected: 0-10 --> INPUT RANGE IN VOLT 2-10 --> INPUT RANGE IN VOLT 0.0-1 --> INPUT RANGE IN VOLT 0.2-1 --> INPUT RANGE IN VOLT DEC.P 1111 --> DECIMAL POINT POSITION 111.1 --> DECIMAL POINT POSITION 11.11 --> DECIMAL POINT POSITION 1.111 --> DECIMAL POINT POSITION LR.LO xxxx --> SET RESISTANCE VALUE LOW LR.HI xxxx --> SET RESISTANCE VALUE HIGH DI.LO xxxx --> DISPLAY READOUT LOW

DI.HI xxxx --> DISPLAY READOUT HIGH REL.U PERC --> SET RELAY IN PERCENTAGE DISP --> SET RELAY IN DISPLAY UNITS TYPE CU --> SELECT CU SENSOR TYPE PT --> SELECT PT SENSOR TYPE NI --> SELECT NI SENSOR TYPE TC --> SELECT TC SENSOR TYPE CU.TY 10 --> SELECT CU SENSOR TYPE 20 --> SELECT CU SENSOR TYPE 50 --> SELECT CU SENSOR TYPE 100 --> SELECT CU SENSOR TYPE PT.TY 10 --> SELECT PT SENSOR TYPE 20 --> SELECT PT SENSOR TYPE 50 --> SELECT PT SENSOR TYPE 100 --> SELECT PT SENSOR TYPE 200 --> SELECT PT SENSOR TYPE 250 --> SELECT PT SENSOR TYPE 300 --> SELECT PT SENSOR TYPE 400 --> SELECT PT SENSOR TYPE 500 --> SELECT PT SENSOR TYPE 1000 --> SELECT PT SENSOR TYPE NI.TY 50 --> SELECT NI SENSOR TYPE 100 --> SELECT NI SENSOR TYPE 120 --> SELECT NI SENSOR TYPE 1000 --> SELECT NI SENSOR TYPE CONN When Cu, Pt and Ni sensor is selected 2W --> SELECT 2-WIRE SENSOR CONNECTION 3W --> SELECT 3-WIRE SENSOR CONNECTION 4W --> SELECT 4-WIRE SENSOR CONNECTION TC.TY TC. B --> SELECT TC SENSOR TYPE TC. E --> SELECT TC SENSOR TYPE TC. J --> SELECT TC SENSOR TYPE TC. K --> SELECT TC SENSOR TYPE TC. L --> SELECT TC SENSOR TYPE TC. N --> SELECT TC SENSOR TYPE TC. R --> SELECT TC SENSOR TYPE TC. S --> SELECT TC SENSOR TYPE TC. T --> SELECT TC SENSOR TYPE TC. U --> SELECT TC SENSOR TYPE TC.W3 --> SELECT TC SENSOR TYPE TC.W5 --> SELECT TC SENSOR TYPE TC.LR --> SELECT TC SENSOR TYPE DEC.P When temperature selected 1111 --> DECIMAL POINT POSITION 111.1 --> DECIMAL POINT POSITION UNIT °C --> DISPLAY AND RELAY SETUP IN CELSIUS °F --> DISPLAY AND RELAY SETUP IN FAHRENHEIT

Page 20: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

20 5715V102-UK

REL1 SET --> ENTER RELAY 1 SETUP SKIP --> SKIP RELAY 1 SETUP OFF --> RELAY 1 DISABLED SETP xxxx --> RELAY SETPOINT ACT1 INCR --> ACTIVATE AT INCREASING SIGNAL DECR --> ACTIVATE AT DECREASING SIGNALL HYS1 xxxx --> RELAY HYSTERESIS ERR1 HOLD --> HOLD RELAY AT ERROR ACTI --> ACTIVATE RELAY AT ERROR DEAC --> DEACTIVATE RELAY AT ERROR NONE --> UNDEFINED STATUS AT ERROR ON.DE xxxx --> RELAY ON-DELAY IN SECONDS OF.DE xxxx --> RELAY OFF-DELAY IN SECONDS RELX (X = 2...4) SET --> ENTER RELAY 2 SETUP SKIP --> SKIP RELAY 2 SETUP OFF --> RELAY 2 DISABLED SETP xxxx --> RELAY SETPOINT ACTX (X = 2...4) INCR --> ACTIVATE AT INCREASING SIGNAL DECR --> ACTIVATE AT DECREASING SIGNAL HYSX (X = 2...4) xxxx --> RELAY HYSTERESIS ERRX (X = 2...4) HOLD --> HOLD RELAY AT ERROR ACTI --> ACTIVATE RELAY AT ERROR DEAC --> DEACTIVATE RELAY AT ERROR NONE --> UNDEFINED STATUS AT ERROR ON.DE xxxx --> RELAY ON-DELAY IN SECONDS OF.DE xxxx --> RELAY OFF-DELAY IN SECONDS A.OUT 0-20 --> OUTPUT RANGE IN mA 4-20 --> OUTPUT RANGE IN mA 20-0 --> OUTPUT RANGE IN mA 20-4 --> OUTPUT RANGE IN mA O.LO xxxx --> DISPLAY VALUE FOR OUTPUT LOW O.HI xxxx --> DISPLAY VALUE FOR OUTPUT HIGH O.ERR 23 mA --> NAMUR NE43 UPSCALE AT ERROR 3,5 mA --> NAMUR NE43 DOWNSCALE AT ERROR 0mA --> DOWNSCALE AT ERROR NONE --> UNDEFINED OUTPUT AT ERROR

RESP xxx.x --> ANALOGUE OUTPUT RESPONSE TIME IN SECONDS E.PAS NO --> ENABLE PASSWORD PROTECTION YES N.PAS xxxx --> SELECT NEW PASSWORD ADV MENU: LANG --> ENTER LANGUAGE SETUP DISP --> ENTER DISPLAY SETUP CAL --> PERFORM PROCESS CALIBRATION HLP.T DE --> DE - WAEHLE DEUTSCHEN HILFETEXT DK --> DK - VAELG DANSK HJAELPETEKST ES --> ES - SELECCIONAR TEXTO DE AYUDA EN ESPANOL FR --> FR - SELECTION TEXTE D’AIDE EN FRANCAIS IT --> IT - SELEZIONARE TESTI DI AIUTO ITALIANI SE --> SE - VALJ SVENSK HJALPTEXT UK --> UK - SELECT ENGLISH HELPTEXT CZ --> CZ - VYBER CESKOU NAPOVEDU LIGH xxxx --> ADJUST DISPLAY LIGHT INTENSITY CA.LO YES --> CALIBRATE INPUT LOW TO PROCESS VALUE? NO CA.HI YES --> CALIBRATE INPUT HIGH TO PROCESS VALUE? NO VAL.L xxxx --> SET VALUE FOR LOW CALIBRATION POINT VAL.H xxxx --> SET VALUE FOR HIGH CALIBRATION POINT USE.C YES --> USE PROCESS CALIBRATED VALUES? NO

Page 21: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

5715V102-UK 21

CONFIGURATION / OPERATING THE FUNCTION KEYS

Documentation for the routing diagramIn general:

When configuring the display you are guided through all parameters, allowing you to choose the settings which fit the application. For each menu there is a scrol-ling help text which is automatically shown in the display if no key has been activated for appr. 5 seconds.

Configuration is carried out by way of the 3 function keys 1 2 and 3. 1 will increase the numerical value or choose the next parameter. 2 will decrease the numerical value or choose the previous parameter. 3 will accept the chosen value and go to the next menu. If a function does not exist in the hardware, all parametres belonging to that function will be skipped in order to make configuration as simple as possible. The configuration will not be saved until the end of the menu structure when the display shows - - - -.

Pressing and holding 3 will return to the previous menu or go back to the default state (1.0) without saving the changed values or parameters.

If no key is activated for 2 minutes, the display will return to the default state (1.0) without saving the changed values or parameters.

Further explanations:Fast setpoint adjustment and relay test: These menus are interactive and allow

you to adjust the setpoints while the display is measuring the input signal. The diodes will then indicate when the relays change state, thus easing the setpoint adjustment in many situations. By activating 1 and 2 simultane-ously, a relay test will be initiated and the relay will change state. The setpoint adjustment will be saved by a quick press of 3 . Holding down 3 for more that 0.5 seconds wil return the display to the default state (1.0) without changing the setpoint.

Password protection: Using a password will block access to the menu and para-meters. There are two levels of password protection. Passwords be tween 0000 and 4999 allow access to the fast setpoint adjustment and relay test menus (using this password blocks access to all other parts of the menu). Passwords between 5000 and 9999 block access to all parts of the menu, fast setpoint and relay test (current setpoint is still shown). Default password 2008 allows access to all configuration menus.

Page 22: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

100

90

80

70

60

50

40

30

20

10

0 10 20 30 40 50 60 70 80 90 100

t

Off N.O. Off N.O.On N.O.

On N.C. On N.C.Off N.C.

100

90

80

70

60

50

40

30

20

10

0 10 20 30 40 50 60 70 80 90 100

t

Off N.O. Off N.O.On N.O.

On N.C. On N.C.Off N.C.

22 5715V102-UK

PROGRAMMING VIA PCBy way of PReset, a simple yet sophisticated PC program, all operational parame-

ters in the 5715 can be quickly configured to suit any application. Furthermore, the PC configuration allows you to set up a customer-defined input type for the input signals current, voltage, resistance and potentiometer. This input type can be defined with special input spans, e.g. 5...12 mA, and customer-defined linearisation with or without offset. The customer-defined input type is saved in the 5715 in the input menu C.LIN. If the display is later configured by way of the front keys for e.g. temperature input, the input type C.LIN containing all the original parameters can be subsequently selected. The PC configuration is sent to the display by way of the communications interface USB Loop Link.

Graphic depiction of the relay function setpoint

Relay unitsRelay units

Setpoint = 50

Hysteresis = 10

Hysteresis = 10

Setpoint = 50

Relay action: Increasing Relay action: Decreasing

Page 23: 5715 - PR electronics series... · 2020-02-03 · Vores motto »Signals the Best« er indbegrebet af denne filosofi – og din garanti for kvalitet. PR electronics A/S offers a wide

Programmable displays with a wide selection of inputs and outputs for display of temperature, volume and weight, etc. Feature linearization, scaling, and difference measurement functions for programming via PReset software.

Displays

A wide selection of transmitters for DIN form B mounting and DIN rail devices with analog and digital bus communication ranging from application- specific to universal transmitters.

Temperature

Galvanic isolators for analog and digital signals as well as HART® signals. A wide product range with both loop-powered and universal isolators featuring linearization, inversion, and scaling of output signals.

Isolation

Interfaces for analog and digital signals as well as HART® signals between sensors / I/P converters / frequency signals and control systems in Ex zone 0, 1 & 2 and for some devices in zone 20, 21 & 22.

Ex interfaces

PC or front programmable devices with universal options for input, output and supply. This range offers a number of advanced features such as process calibration, linearization and auto-diagnosis.

Universal