  • 9393 Princeton-Glendale Road Hamilton, Ohio USA 45011 Phone: (800) 422-2525 Fax: (800) 421-3297102 9393 Princeton-Glendale Road Hamilton, Ohio USA 45011 Phone: (800) 422-2525 Fax: (800) 421-3297

    NEW!

    Now you can be with the New OPW Testable 71SO

    Overfill Prevention Valve

    The easiest, most affordable way to ensure overfill compliance

    Are you Prepared for New EPA

    Overfill Valve Test Requirements?

    u UST systems (drop tube, overfill prevention valve, spill containers) must be tested for vapor tightness

    u Overfill prevention valves shut off devices must be manually inspected

    Patent Pending

    Spend 60 Seconds vs 60 Minutes per Tank!

  • www.opwglobal.com 1039393 Princeton-Glendale Road Hamilton, Ohio USA 45011 Phone: (800) 422-2525 Fax: (800) 421-3297

    The OPW Testable 71SO helps you prepare for these regulations

    u The Only UST Overfill Prevention Valve that is testable without removal from the tank

    u A testable feature is attached to a sealed plug in the inlet Adaptor

    u The plug is easily accessed with a standard socket extension

    u Attached to the extension, the testable feature can be raised and lowered, allowing the user to inspect the valve operation from the inside of the tube

    u The plug is then easily reinstalled to the inlet Adaptor from grade

    u No fill components, overfill valves, or vapor tight seals have to be removed - avoids compromising vapor tight compliance

    u The Testable 71SO uses the same industry leading overfill prevention technology for strong vapor tight compliance

    Testable 71SO Overfill Prevention Valve

    Patent Pending

    1

    Loosen test plug

    2

    Lift float with cable to simulate fill

    Validate proper poppet operation

    3

    Easy as 1 2 3Testing & Verification

    Ordering Specifications

    Product # DescriptionA- Upper

    Tube Length B- Lower

    Tube LengthC- Overall

    LengthMax. Riser

    LengthMax. Nomi-

    nal Tank Dia.Max. Actual

    Tank Dia.Weight

    in. m in. m in. m in. m in. m in. m lbs. kg

    71SO-400CTTestable Vapor-Tight Overfill Valve, 5 Ft. Bury, 8 Foot Tank

    60 1.5 83 2.1 1543/4 3.9 531/2 1.4 96 2.4 107 2.7 16 7

    71SO-410CTTestable Vapor-Tight Overfill Valve, 10 Ft. Bury, 10 Foot Tank

    120 3.1 102 2.6 2343/4 5.9 1131/2 2.9 120 3.1 126 3.2 25 11

    71SO-420CTTestable Vapor-Tight Overfill Valve, 10 Ft. Bury, 12 Foot Tank

    120 3.1 126 3.2 2583/4 6.5 1131/2 2.9 144 3.7 150 3.8 26 12

    NOTE: The OPW 71SO is designed for use on tight-fill gravity drop applications only. Do not use for pressure fill applications.

    Look for this label for authentic OPW EVRApproved products.

    Listings and Certifications