Toledo Refinery Site Technical Practices EP 8-1-4DS Air Cooled Heat Exchangers Data Sheet August 2007 Revision 0.0 Page 1 of 3 Maintained by E 2 G – Shaker Heights, OH PROJECT PROJECT NO. INQUIRY NO. LOCATION UNIT EQUIPMENT ID JOB NO. DOCUMENT NO. DATA ISSUED FOR IN-HOUSE REVIEW TOLEDO REFINERY APPROVAL QUOTATION PURCHASE CONSTRUCTION THIS SHEET IS A RECORD OF EACH ISSUE OR REVISION TO THE SUBJECT DATA. EACH TIME THE DATA IS CHANGED ONLY THE NEW OR REVISED DATA SHEETS NEED TO BE ISSUED. THE EXACT SHEETS CHANGED AND THE NATURE OF THE CHANGE SHOULD BE NOTED UNDER REMARKS. THESE REMARKS ARE NOT A PART OF THE DATA. THE REVISED DATA SHEET(S) BECOME PART OF THE ORIGINAL DATA AND SHALL BE COMPLIED WITH IN THEIR ENTIRETY. ALL DATA SHEETS ATTACHED REVISED DATA SHEET(S) ONLY ATTACHED REV. DATE BY CHECK APPROVALS REMARKS SECTION PROJECT TOLEDO REFINERY

Upload: esganfia

Post on 02-Feb-2016

214 views

Category:

Documents


0 download

DESCRIPTION

from

TRANSCRIPT

Page 1: 8_1_4DS

Toledo Refinery

Site Technical Practices EP 8-1-4DS

Air Cooled Heat Exchangers Data Sheet

August 2007 Revision 0.0

Page 1 of 3

Maintained by E2G – Shaker Heights, OH

PROJECT

PROJECT NO.

INQUIRY NO.

LOCATION

UNIT

EQUIPMENT ID

JOB NO.

DOCUMENT NO.

DATA ISSUED FOR

IN-HOUSE REVIEW

TOLEDO REFINERY APPROVAL

QUOTATION

PURCHASE

CONSTRUCTION

THIS SHEET IS A RECORD OF EACH ISSUE OR REVISION TO THE SUBJECT DATA. EACH TIME THE DATA IS CHANGED ONLY THE NEW OR REVISED DATA SHEETS NEED TO BE ISSUED. THE EXACT SHEETS CHANGED AND THE NATURE OF THE CHANGE SHOULD BE NOTED UNDER REMARKS. THESE REMARKS ARE NOT A PART OF THE DATA. THE REVISED DATA SHEET(S) BECOME PART OF THE ORIGINAL DATA AND SHALL BE COMPLIED WITH IN THEIR ENTIRETY.

ALL DATA SHEETS ATTACHED

REVISED DATA SHEET(S) ONLY ATTACHED

REV. DATE BY CHECK APPROVALS REMARKS

SECTION PROJECT TOLEDO REFINERY

Page 2: 8_1_4DS

Toledo Refinery

Site Technical Practices EP 8-1-4DS

Air Cooled Heat Exchangers Data Sheet

August 2007 Revision 0.0

Page 2 of 3

Maintained by E2G – Shaker Heights, OH

EQUIPMENT ID JOB NO. DOCUMENT NO REV.

1. Service: 2. 3. ft2 4. Size & Type : Induced Forced Draft No. of Bays: 5. Surface per Unit - Finned Tube: ft2, Bare Tube: ft2 6. Heat Exchanged: Btu/h MTD. Eff: oF 7. Transfer Rate - Finned tube: ; Bare Tube Service: Clean Btu/h. ft2 oF 8. PERFORMANCE DATA - TUBE SIDE 9. Fluid Name Lethal Service (Yes) (No) IN OUT 10. Total Fluid Entering Density, Liquid lb/ft3

11. IN OUT Specific Heat Capacity Btu/lb oF

12. Temperature Cond. Liq. Vap. Btu/h.ft. oF

13. Liquid lb/h (Pour) (Freeze) Point oF

14. Vapor lb/h mol.wt. Bubble Point �F

15. Noncond. lb/h mol.wt. Latent Heat Btu/lb

16. Steam lb/h Inlet Pressure (psig) (psia)

17. Water lb/h Pressure Drop. Allow./Calc. psi /

18. Viscosity (Liq) (Vap) CP Fouling Resist., Inside h. ft2 oF/Btu

19. PERFORMANCE DATA - AIR SIDE 20. Air quantity, Total : (lb/h) (SCFM) Altitude above Sea Level: ft. 21. Air quantity, Fan: ACFM Temperature in (Design Dry Bulb): oF 22. Actual Static Pressure: in. water Temperature Out : oF 23. Face Velocity: std. ft/min Mass Velocity (Net Free Area): lb/h.ft2 Minimum Design Ambient: oF 24. DESIGN - MATERIALS - CONSTRUCTION 25. Design Pressure psig Test Pressure CODE psig Design Temperature/MDMT / oF 26. TUBE BUNDLE HEADER, Type TUBES, Material 27. Size Material (Seamless) (Welded) 28. No. Bay No. Tube Rows No. Passes* Slope in./ft. OD in. MW in. 29. Arrangement Plug Material No. Bundle Length ft. 30. Bundles: In Parallel In Series Gasket Material Pitch in. ∆ 31. Bays: : In Parallel In Series Corrosion Allowance in. FIN, type 32. Bundle Frame No., Size Inlet Nozzle in. Material 33. MISCELLANEOUS No., Size Outlet Nozzle in. OD in. Stock Thick. in. 34. Struct. Mount. Piperack Grade

c/c Special Nozzles in. No./in. Fin Des. Tem. oF

35. Surface Preparation Rating and Facing Code - ASME VIII, Div. 1 Stamp (Yes) 36. Louvers: Auto Manual Tl Pl 37. Vibration Switches Chem. Cleaning 38. Remarks:

* Give tube count of each pass when irregular ** Motors shall be in accordance with EP 13-3-1 and a completed Motor Data Sheet from EP 13-3-1DS.

Page 3: 8_1_4DS

Toledo Refinery

Site Technical Practices EP 8-1-4DS

Air Cooled Heat Exchangers Data Sheet

August 2007 Revision 0.0

Page 3 of 3

Maintained by E2G – Shaker Heights, OH

EQUIPMENT ID JOB NO. DOCUMENT NO REV.

MECHANICAL EQUIPMENT 39 FAN, Mfr. & Model DRIVER, Type** SPEED REDUCER, Type 40 No./Bay RPM Mfr. Mfr. & Model 41 Dia. No. Blades No. Bay HP/driver No. Bay 42 PitchAdj.Auto. Angle RPM AGMA Rating HP Rated 1 43 Material, Blade Hub Enclosure Support (Structural) 44 HP, Fan. Des. Minimum Amb. Volt, Phase, Cycle 45 Control Action on Air Failure - Fan Pitch: (Minimum) (Maximum) (Lockup) Louver: (Open) (Close) (Lockup) 46 Degree Control of Outlet Process Temperature (Maximum Cooling) (± °F) 47 Recirculation (None) (Internal) (External Over Side) (External Over End) Steam Coil (Yes) (No) 48 NOTES: * Give tube count of each pass when irregular 49 ** Motors shall be in accordance with EP 13-3-1 and a completed Motor Data Sheet from EP 13-3-1DS. 50 51 MISCELLANEOUS DATA 52 Plot Area ft2 Weight of Bundle lb. Shipping Weight lb. 53 REMARKS: