    Remanufacturing Instructions H P 8500 Black Toner Car tri dge

    Technical SupportMemphis, TN (888) 757-0762

    Nashua, NH (888) 833-5727

    5. Locate and remove the four screwsfrom the non-geared end of thecartridge.

    6. Once the screws have beenremoved, gently pry of the end-cap.

    7. Remove the cartridge end-cap. Becareful not to lose the small blackbearing that rides in a recessed area inthe developer roller magnet housing. Thebearing is unattached and will fall outeasily.

    8. Locate and remove the three screwson the opposite end (geared end) ofthe cartridge.

    Note: It is not necessary for the shutteractuator arm to be removed, it mayremain attached to the end-cap.Although it is not necessary to removethis end-cap to take out the developerroller, it is recommended to facilitate

    cleaning the contacts that are located onthe inside of the end-cap.

    Fig. 3

    Fig. 4

    Fi . 5

  • 8/13/2019 8500Bl

    3/4

    2004 Oasis Imaging Products, Inc. Page 3 of 3

    Remanufacturing Instructions H P 8500 Black Toner Cartr idge

    Technical SupportMemphis, TN (888) 757-0762

    Nashua, NH (888) 833-5727

    9. While removing the end-cap becareful as none of the drive gears aresecured to the hopper. Also, becareful not to lose the developer roller

    contact spring, located on the end ofthe developer roller.As on the non-geared side of thedeveloper roller, there is also anunattached bearing that resides in anindention in the end-cap, do not losethis.

    10. Clean off all contamination fromthe contacts using 99% IPA and acotton swab, take care not to leaveany lint in the contact area.

    NOTE: Be sure you have cleaned thedeveloper roller contact springthoroughly.

    11. If you do not want to remove thedrive gears, it is possible to removethe developer roller and then re-attach the end cap for fillingthrough the developer rolleropening.

    12. Remove the developer roller. (Inthis photo, the end-cap on the gearedside has not been removed.)

    13. Clean both the roller and inside ofthe toner hopper with clean, filteredcompressed air.

    Fig. 6

    Fig. 7

    Fig. 8

    If some or all of the gearshave fallen off the side ofthe cartridge, use this

    picture to reaffix them inthe proper location.

  • 8/13/2019 8500Bl

    4/4

    2004 Oasis Imaging Products, Inc. Page 4 of 4

    Remanufacturing Instructions H P 8500 Black Toner Car tri dge

    Technical SupportMemphis, TN (888) 757-0762

    Nashua, NH (888) 833-5727

    Oasis and You Succeeding Together!

    2004 Oasis Imaging Products, Inc. Any attempt to reproduce any part of these instructions without the written consent ofOasis Imaging Products, Inc. may result in legal action. All registered trademarks are the property of their respective owners.

    New Hampshire(603) 880-3991(888) 627-6555Fax: (603) 598-4277

    Tennessee(901) 433-0334Fax: (901) 366-9756

    Texas(972) 671-1307(888) 591-3555Fax: (972) 671-1359

    Canada(905) 568-3422(800) 430-7886Fax: (905) 568-3491

    Illinois(630) 982-1543(888) 658-4555Fax: (630) 928-1542

    California(714) 283-6270(888) 656-9555Fax: (714) 283-6276

    North Carolina(919) 776-0847(866) 399-8558Fax: (919) 776-0898

    EuropeNetherlands011-31-24-388-2233Fax: 011-31-24-355-7373

    14. To maintain optimum print qualityit is recommended to replace theDr. Blade assembly each cycle. Toremove the Dr. Blade take out thetwo screws that hold the blade in

    place.

    15. Once the blade is removed, fill withtoner and re-assemble in reverse order.

    Fig. 9