9390 brochure
TRANSCRIPT
![Page 1: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/1.jpg)
Powerware series
Eaton 9390 UPS 40-160 kVA
Enhanced energy efficiency
![Page 2: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/2.jpg)
•Healthcare
2 EATON CORPORATION Eaton 9390 UPS
![Page 3: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/3.jpg)
Introduction and overview
Key applications•Datacentres
•Financialservices
•Buildingmanagement
•Telecommunications
•Industrialautomationequipment
TheEaton®9390uninterruptiblepowersystem(UPS)40-160kVAofPowerware®seriesisadouble-conversionUPSthatresolvesallutilitypowerproblemsandsuppliesclean,continuous,uninter-ruptiblepowertoconnectedequipment.Whetheryou’reselectingaUPSforabranchoffice,manufacturingfloor,medicalfacilityordatacentre,there’sa9390modelthatdeliversjusttherightcom-binationofperformanceandpriceforyourneeds.
Benefits
Enhanced power performance
–Double-conversiondesignforhighestpowerprotection
–Widvoltagerangeoffering
–TheUPSisoptimisedforprotectingmodern0.9p.f.-ratedITequipment
–LowinputITHDenhancescompatibilitywithextendedbackpowersources(generators)
Outstanding efficiency and cost savings
–Highefficiencyratingsindouble-conversionmodelowerutilitycostssubstantially
–InnovativeEnergySavingSystem(ESS)technologyenablesUPStoachieveanimpressiveefficiencyof99percent
–Lowtotalcostofownershipandlifecyclecarbonfootprint
–Lowtransportationandinstallationcostswiththesmallfootprintandweight
–ReductioninenergyconsumptionduringtestingwithEasyCapacityTest(ECT)technology
Highest reliability and availability
–PowerwareHotSync®parallelingtechnologyerasessinglepointoffailureinparallelsystems.HotSyncsystemsarecapableofparallelingforbothredundancyandcapacity.
–SuperiorbatterymanagementwithABM®technology
–Scalablearchitectureadaptstomatchyourpowerrequirements
Robust manageability
–SuperiorcontrolofnetworkedUPSswithinnovativeIntelligentPower®Managersoftwaretool
–Connectivityoptionsareavailabletosuitvirtuallyanycommu-nicationrequirement,fromstandardserialcommunicationstosecureremotemonitoringovertheweb
Customised solutions
–Customisedsystemstomeetdifferentcustomerandmarketrequirements
–Arangeofserviceagreementoptionscanbeeasilycustomisedforcustomers´needsandbudget
www.eaton.com/powerquality 3
![Page 4: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/4.jpg)
Enhanced power performance
Double-conversion design for highest power protection
UnlikesomeothercommerciallyavailableUPStechnologies,thedouble-conversiondesignusedinthe9390completelyisolatesoutputpowerfrominputpoweranomaliesanddelivers100-per-centconditioned,perfectsinewaveoutput,regulatingbothvolt-ageandfrequency.Evenwhenpresentedwiththemostseverepowerdisturbances,poweroutputremainsstable.
Enhanced power performance
Powerperformance,whichismeasuredbysystemefficiency,ITHD,inputandoutputpowerfactoristhefoundationofthe9390.
Inthestandarddouble-conversionmode,the9390deliverseffi-ciencyofupto94percent.Thishighlevelofpowerperformanceisenabledbymoderntransformer-freetechnologythatincorpo-ratessmall,lightweightfilterinductors,highperformanceIGBTsinbothrectifierandinverter,andanadvancedcontrolalgorithm.ThankstotheIGBTtechnology,the9390doesnotrequireinputfilterstoobtainexcellentinputITHD.
DuetoitslowinputITHD(below4.5percentatfullload)andhighinputpowerfactor(over0.99),the9390isexceptionallycompat-iblewithdiversepowersources,especiallygenerators.The9390isalsoextremelymainsfriendlyduetoitslowharmoniccontent.
The9390UPSisoptimisedfor0.9p.f.,meaningyougetmorerealpowerforyourmoney.Ontheoutputsidethe9390canprovideitsfullpowercapability,asitsupportsleadingpowerfactorloads,whicharebecomingmoreprevalentinnewandupdateddatacen-tres.The9390UPShandlesdownto0.8leadingpowerfactorofmoderncomputerandserverloads.
Loadpowerfactorrangechart
Full range of load power factor
LaggingLeading
ManycompetitiveUPSscannotoperateinthisrangewithoutsignificantderating
Without derating
Consistent efficiency throughout the UPS load range.
ManyUPSscitegreaterthan90percentefficiencywithoutmen-tionoflowornoloadrange.Today’saveragesystemoperatesatonly55percentofitsratedloadorcapacityrange.However,effi-ciencyisusuallyreducedinthislowerloadoperatingstatus.Thisisnotthecasewiththe9390,whichreachesoptimalefficiencyratesatlessthanhalfload-andmaintainsthisoptimalefficiencythroughouttheloadrange.
4 EATON CORPORATION Eaton 9390 UPS
![Page 5: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/5.jpg)
Substantially improved efficiency with Energy Saver System
Eaton´sinnovativeEnergySaverSystem(ESS)technologyenablesUPSefficiencytoreachanimpressive99percent.Inthestandarddouble-conversionmodetheUPSoperatesasnormal,supply-ingpowerthroughthepowerconverters.WithESSthepowerconvertersarein“ready”stateandthestaticbypassswitchisusedtosafelyprovidemainscurrentdirectlytotheload.Ifmainspowerislostorexceedspresetoutputlimits,theDClinkthatiskeptactiveenablesaseamlessswitchovertodoubleconversioninlessthantwomilliseconds.WhileinESS,theUPSisalsoabletodetectwhetherafaulthasbeencausedbyasourceorbyaload.Afaultatthebypasssourceresultsinimmediateswitchovertotheinverter;afaultintheloadkeepstheUPSinESSmode.
ThetablebelowshowsexamplesforaUPSsystematdifferentloadlevels.TheESSenables100percentoftheUPScosttoberecoveredwithinthreetofiveyears.
Outstanding efficiency and cost savings
Critical load 50 kW 125 kW 250 kW 500 kW 700 kW
Electric costs (energy + demand) in € per kWhr 0.11 0.11 0.11 0.11 0.11
Legacy UPS efficiency (%) 92.5 92.5 93 93 93
Eaton Energy Saver System UPS efficiency (%) 99 99 99 99 99
Three-year energy savings (MWhrs) 145 363 670 1340 1876
Three-year CO2 savings (metric tons) 104 261 481 962 1347
Three-year utility cost savings (€) 15.972 39.929 73.715 147.431 206.403
UPS EFFICIENCIES EATON UPS WITH ESS
EATON UPS
LEGACY UPS
UPS
EFF
ICIE
NC
Y
TYPICAL OPERATION
UPS LOAD
ActivecomponentsengagedinESSmode.
ESSsavingsaresignificantacrossallloadrangesandcompoundbasedondatacentresize.PresetDCIE(Datacentreinfrastructureefficiency)inthisexampleis70percent.
www.eaton.com/powerquality 5
![Page 6: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/6.jpg)
Highest reliability and availability
Powerware Hot Sync technology boosts power reliability
Eaton’sHotSynctechnologyisdesignedforparallelredundantN+1systemstosatisfy24/7applications.Itcanalsobeusedinparallelcapacitysystemstoenablecustomerswithever-increasingloaddemandstotakeadvantagesofthescalabilitybenefitsitoffers.ThankstoHotSync,uptosevenequivalent9390modulescanbeparalleledforadditionalcapacityorredundancy.
Accurate,equalloadshareisthenumberonecharacteristicthatdeterminestheintegralqualityandreliabilityofaparallelUPSsys-tem.WithHotSynctechnologythisisachievedwithouttheneedforcommunicationbetweentheUPSsthusnosinglepointoffail-ureisaddedwhenintroducingparallelmodulestoasystem.Fromanoperationalandeconomicalviewpoint,theachieved“closetoperfect”reliabilitybringsclearsavingsinthelongrun,aseverydowntimeincidentiscostlyandmightleadtounpredictableconse-quences.
Thetwo-modulesystemshowninthepicturebelowcanbecon-figuredas160kVAN+1redundant(320kVAcapacitywithatiecabinet).
The benefits of Hot Sync:
•Erasessinglepointoffailure
•Systemsarecapableofparallelingforbothredundancyandcapacity
•Ensuresthateachmoduleisoperating independently
•Noaddedcircuitryorcomponentsarerequiredfor astandardUPStobeswitchedintooperateinparallel
•Aproventechnology-thousandsofsystemsareoperat-ingsuccessfullyaroundtheworld
Battery 160 kVA UPS Modules
Tie Cabinet
Battery
6 EATON CORPORATION Eaton 9390 UPS
![Page 7: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/7.jpg)
ABM optimises battery performance and service life
TheABMtechnologyusedinthe9390UPSmaximisesthehealthandservicelifeofbatteries:
•ABMtechnologyusesauniquethree-stagechargingtechniquethatsignificantlyextendsbatteryservicelifeandoptimisesrechargetimecomparedtotraditionaltricklecharging
Easy Capacity Test reduces costs
The9390hastheuniqueabilitytotestitsentirepowertrainunderfullloadstresswithouttherequirementofanexternalloadthankstoEasyCapacityTest(ECT).Withnoloadconnected,the9390isabletotestallofitspowerhandlingcomponents,includingtherectifier,inverter,contactors,fuses,powerbusses,cabling,batteries,bypass(staticswitch),magneticsandfiltercapacitors.Furthermore,the9390hastheabilitytotesttheupstreambypassinputbreaker(BIB),therectifierinputbreaker(RIB)andallofthe
electricalcablesbetweenthem.Thenetresultofthisinnovativeloadtestisthattherearenoloadbankstorent,notemporaryloadconnectionstomake,nowastedenergy,thussavingyoutimeandmoneyduringstartupandcommissioningtests.Eatonfieldtechni-ciansaretrainedtousethisloadtestingcapabilityduringastartupservicetoensureoptimumcalibration,maximumefficiencyandinherentredundancy.
EasyCapacityTestPowerFlow
UTILITY FASILITY EATON 9390 UPS
RECTIFIER
STATIC SWITCH
INVERTER
BATTERY
BatteryvoltageduringoneABMchargingcycle
• Temperature-compensatedchargingmonitorsbatterytempera-tureandadjuststhechargerateaccordingly,whichproperlychargesthebatteryandgreatlyextendsbatterylife
•Anintegratedbatterymanagementsystemtestsandmonitorsbatteryhealthandremaininglifetime,providingusernotifica-tionstoguidepreventivemaintenance
www.eaton.com/powerquality 7
![Page 8: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/8.jpg)
9390–bigpower,smallfootprint
Cost-effective design
The9390offersthesmallestfootprintofanyUPSinitsclass–10to35percentsmallerthancompetingunits.Withatransformer-freedesign,theEaton9390UPSmeetsorexceedsvirtuallyallfloorloadingstandards,anditslowweightmeansunitscanbemovedwithoutheavyliftingequipmentandwillfitinallstandardfreightelevators.
CablingcanentertheUPSfromeitherthetoporbottomofthecabinettoprovideeasierandflexibleinstallation.The9390pro-videsfront-panelaccessforallservicesandoperation,increas-ingserviceabilityandreducingmeantimetorepair(MTTR).Andsincethecompact,front-accessible9390cabinetcanbeinstalledagainstbackandsidewalls,youhavemorelocationoptions,installationandserviceisfastandeasy,deploymentcostislower,andyousavevaluablefloorspace.
CompetingUPS’sfootprint
External battery cabinets
Eatonofferstwoversionsofbatterycabinets,whichlineupandmatchwiththe9390cabinetdesign,eachofferingawidearrayof runtimes.
•Daisychaincabinetstogetherforextendedruntimes
•Remoteconfigurationsareavailable
•Front-access-onlydesignandtop/bottomcableentryprovidesinstallationflexibilityandenhancesservicing
•Optionaltemperature-compensatedchargingisavailable
8 EATON CORPORATION Eaton 9390 UPS
![Page 9: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/9.jpg)
Relay interface cards
TheX-Slotrelayinterfacecardprovidesfourprogrammableisolat-eddrycontactForm-Crelayoutputs(defaultsetting:utilityfailure,lowbattery,UPSalarm/OK,onbypass)andoneinput.
NetWatchisashutdownagentfortheConnectUPSWeb/SNMPcard.Itisaverycompactpieceofsoftware,butstillfeaturespow-erfulconfigurationoptionsforshutdownactions,timingsandusernotification.
LanSafe®isanetworkshutdownsoftwareproductthatcur-rentlysupportsupto20operatingsystems.Itensurescontrolledsequentialshutdownofthewholenetworkacrossplatformsincaseofaprolongedpowerfailure.LanSafeallowstheshutdownofupto64computersprotectedbyasingleUPS.
Intelligent Power Manager isasoftwaretoolformanagingnet-workedUPSandPDUsystemsmoreeasilyandatlowercostthanthemajorNMSplatforms,andisdedicatedtopowermanagementfunctions.Administratorshaveanoverall,consolidatedviewofthemainoperatingparametersofallUPSsystems.Theweb-basedinterfaceisintuitiveandeasytouse,whilealsoofferinghighcon-figurabilityandpowerfulfeatures.
IntelligentPowerManagercentralisesalarmmanagement.Itcancollateseveraleventsintoasinglemessageanddeliverthemes-sageviaemailorSMS.
IntelligentPowerManagerisveryeasyandfasttoinstall.Oncerunning,thesoftwarediscoversmanageablepowerdevicesauto-maticallyandisoperationalinjustafewseconds.
AversionofIntelligentPowerManagerlimitedto10monitoreddevicesisavailablefreewitheachnetworkedEatonUPS.
Robust manageability
ConnectUPS-XWeb/SNMPX-Slotcard
Modbuscard RelayInterfacecards
EnvironmentalMonitoringProbe
IntelligentPowerManagerLanSafe
Enhanced communication capabilities
The9390UPSisequippedwithavarietyofstandardcommunica-tionsfeaturesfornetworkconnectivityandremotemanagementapplications,including:
•RS-232serialport
•FourX-Slot®communicationbays
•Relayoutputcontacts
•Twoprogrammablesignalinputs
•Remoteemergencypower-off(REPO)
Easy network connectivity and monitoring
ConnectUPS-X card
TheConnectUPS-XWeb/SNMPX-Slotcardconnectsthe9390directlytoanEthernetnetworkandtheInternetandenablesgracefulshutdownofmultiplecomputersoverthenetwork.TheConnectUPS-XWeb/SNMPalsofeaturesathree-portswitchinghub.
Environmental Monitoring Probe
TheEnvironmentalMonitoringProbe(EMP)workswiththe9390andConnectUPS-Xcardtoremotelymonitorambienttemperatureandrelativehumidityoftheremoteenvironment.TheEMPcanalsobeconfiguredtoprovidethestatusoftwoadditionalcontactdevicessuchassmokedetectorsoropen-doorsensors.
Modbus® card
TheModbuscardisanX-Slotdevicethatallowscontinuous,real-timemonitoringofthe9390throughaBuildingManagementSystem(BMS)orindustrialautomationsystem.
www.eaton.com/powerquality 9
![Page 10: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/10.jpg)
Customised solutions
Eatonisexperiencedindeliveringsolutionsforthemostdemand-ingapplications.Asanexample,marineUPSshavespecialdependabilityrequirementsduetotheharshoperationalconditionstheyhavetowithstandandthecriticalnatureoftheequipmenttheyprotect.EatonhassuppliedmarineUPSstohundredsofves-selsovertheyears.
The9390hasbeenalsotestedandcertifiedforuseinmedicalimagingsystemapplicationsbyallmajorsuppliersofX-ray,MRIandCTmachines.
Eatonoffers9390basedcustomizedsystemsfordifferent markets,including:
•Marine/offshore
•Healthcare/medical
•Oil&Gas
•Rail&Track/underground/traffic/tunnel/mines
•Aviation
• Industrialapplications
•Defence/military
•Emergencylighting
Eatonprovidesanextensivetechnicalsupportnetworktocoverthepowerprotectionneedsofourcustomers.Weofferanumberofdistinctservicepackagestomatchdifferenttypesofmainte-nanceneedsandbudgets.Whicheverpackageyouchoose,youcanrestassuredthatitwilldeliverpowersecurityandreliabilitytokeepyourcorebusinessrunning.
Formoreinformation,pleasecontactyourlocalEatonserviceorganisationorauthorisedservicepartner.
Expertise and reliability through Eaton service
10 EATON CORPORATION Eaton 9390 UPS
![Page 11: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/11.jpg)
TEChNICAL sPECIfICATIONs
UPS output power rating (0.9 p.f.)
kVA 40 60 80 100 120 160
kW 36 54 72 90 108 144
GeneralEfficiency in double- conversion mode (full load) 94%
Efficiency in double- conversion mode (half load) 92.5%
Efficiency in Energy Saver System (ESS) Up to 99%
Distributed parallelling with Hot Sync technology Max 6 + 1
Field upgradeable Yes
Inverter/rectifier topology Transformer-free IGBT with PWM
Audible noise <65 dB
Altitude (max) 1000 m without derating (max 2000 m)
Input
Input wiring 3 ph + N + PENominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz
Input voltage range Low -15% at 100% load/-30% at 50% load without battery discharge; High +10%/max +20%
Input frequency range 45-65 Hz
Input power factor 0.99
Input ITHD Less than 4,5%
Soft start capability Yes
Internal backfeed protection Yes
Output
Output wiring 3 ph + N + PENominal voltage rating (configurable) 220/380, 230/400, 240/415 V 50/60 Hz
Output UTHD <3% (100% linear load); <5% (reference non- linear load)
Output power factor 0.9 (e.g. 72 kW at 80 kVA)
Permitted load power factor 0.7 lagging - 0.8 leading
Overload on inverter 10 min 100-110%; 30 sec 110-125%; 10 sec 125-150%; 300 ms >150%
Overload when bypass available
Continuous 100-110%, 10 min 110-150%, 5 ms 1000% Note! Bypass fuses may limit the over-load capability
Battery
Type Maintenance free VRLA batteries, NiCd
Charging method ABM technology or Float
Temperature compensation OptionalBattery nominal voltage (lead-acid) 480 V (40 x 12 V, 240 cells)
Charging current / Model Default A Max* A
40 60 80 100 120 160 10 20 20 30 30 40 20 40 40 60 60 80
*May be limited by maximum UPS input current rating
AccessoriesExternal battery cabinets with long-life batteries, X-Slot connectivity (Web/SNMP, ModBus/Jbus, Relay, Hot Sync, ViewUPS-X remote display), Hot Sync parallel tie cabinet, integrated manual bypass up to 80 kVA, external mainte-nance bypass switch
Communications
X-Slot 4 communication bays
Serial ports 1 available
Relay inputs/outputs 6/3 programmable
Compliance with standards
Safety (CB certified) IEC 62040-1, IEC 60950-1
EMC IEC 62040-2
Performance IEC 62040-3
Standard UPS
Part number Description Rating Dimensions (HxWxD) Weight1028510 9390-40-N-4xO 40 kVA / 36 kW 1879x519x808 mm 257 kg1028511 9390-60-U-4xO 60 kVA / 54 kW 1879x519x808 mm 313 kg1028512 9390-80-N-4xO 80 kVA / 72 kW 1879x519x804 mm 313 kg1028513 9390-100-U-4xO 100 kVA / 90 kW 1879x944x804 mm 430 kg1028514 9390-120-N-4xO 120 kVA / 108 kW 1879x944x804 mm 430 kg1028515 9390-120-U-4xO 120 kVA / 108 kW 1879x944x804 mm 530 kg1028516 9390-160-N-4xO 160 kVA / 144 kW 1879x944x804 mm 530 kgStandard external battery1025570 9390-BAT10-S-40x38Ah (250A) 38 Ah 1877x575x773 mm 700 kg1025572 9390-BAT10-S-200 (250A) 200 W 1877x575x773 mm 1176 kg1026327 9390-BAT10-S-205 (250A) 205 W 1879x1125x808 mm 1270 kg1025467 9390-BAT10-280 (250A) 280 W 1879x1125x808 mm 1430 kg1025468 9390-BAT10-500 (250A) 500 W 1879x1125x808 mm 1444 kg1025469 9390-BAT10-280 (400A) 280 W 1879x1125x808 mm 1625 kg1025470 9390-BAT10-330 (400A) 330 W 1879x1125x808 mm 2188 kg1025471 9390-BAT10-500 (400A) 500 W 1879x1125x808 mm 2188 kgBattery racks1026273 9390-RACK10-1x40x200W 200 W 1714x566x1246 mm 985 kg1026274 9390-RACK10-1x40x280W 280 W 1726x690x1246 mm 1228 kg1026275 9390-RACK10-1x40x330W 330 W 1726x690x1546 mm 1431 kg1026276 9390-RACK10-1x40x390W 390 W 1729x690x1546 mm 1587 kg1026277 9390-RACK10-1x40x500W 500 W 1789x690x1546 mm 1995 kg1026278 9390-RACK10-2x40x500W 500 W 1714x866x1856 mm 3879 kg1026279 9390-RACK10-3x40x500W 500 W 1789x690x3666 mm 5865 kgSee runtime from the runtime specificationStandard accessories1021887 External Bypass Switch 60-80 kVA (wall-mount) wall 840x380x130 mm 17 kg1021888 External Bypass Switch 120 kVA (wall-mount) wall 1040x560x130 mm 25 kg1024626 External Bypass Switch 160 kVA (wall-mount) wall 1040x560x130 mm 25 kg
1025476 SPM-60-2 wall 700x500x250 mm 50 kg1023540 SPM-80-4 floor 1530x520x788 mm 230 kg1024687 9390 Tie Cabinet 3x120 kVA floor 1879x519x808 mm 217 kg1024506 9390 Tie Cabinet 3x160 kVA floor 1879x519x808 mm 217 kg
www.eaton.com/powerquality 11
![Page 12: 9390 Brochure](https://reader033.vdocuments.net/reader033/viewer/2022050900/577cce281a28ab9e788d77c2/html5/thumbnails/12.jpg)
© 2010 Eaton CorporationAll Rights ReservedPrinted in Finland00BROC1018151 rev AApril 2010
Eaton, Powerware, ABM, LanSafe, Hot Sync, Intelligent Power are trade names, trademarks, and/or service marks of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are the property of their respective owners.
www.eaton.com/powerquality
Forassistancewithyourpowerqualityneeds,contactyourlocalEatonserviceandsalesrepresentatives.