a-5 - loopnet€¦ · reflected ceiling plan / notes / details a-5 exchange business center 7330...

1
WC LAV. D.F. UTIL. SINK SINK 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 WC LAV. D.F. UTIL. SINK SINK 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 CEILING KEY NOTES NOTE: EXISTING SPRINKLER HEADS TO BE RELOCATED TO ACCOMODATE NEW WALL LOCATIONS. DRAWINGS AND SPRINKLER WORK TO BE PROVIDED BY LICENSED FIRE SPRINKLER CONTRACTOR UNDER SEPARATE PERMIT. 10 0 SCALE: 1/4' = 1'-0" REFLECTED CEILING PLAN NORTH C1 C2 SURFACE MOUNT INCLUDED LED REFERENCE NOTES: GENERAL NOTES: 8'-6" 8'-6" C A B 4-Light 2 ft. x 4 ft. White High Output Fluorescent High Bay C Model # HBL454T5HO-LP41 (4) T5HO 54W 4100K LAMPS INCLUDED UNIVERSAL 120-277V INPUT METALUX WHITE WHITE LED SUSPENDED AT 22' AFF C C C C 5'-0" 22'-0" 22'-0" 22'-0" 22'-0" 11'-8" 17'-6" C C C C HIGH BAY HIGH BAY HIGH BAY HIGH BAY HIGH BAY HIGH BAY HIGH BAY HIGH BAY HIGH BAY 1 & 3 1 & 3 1 1 1 OPEN TO UNDERSIDE OF STRUCTURE REFLECTED CEILING PLAN LEGEND SYMBOL FIXTURE TYPE MANUFACT. SPECIFICATION FINISH WATTS LAMP MOUNT NOTES CLEAR 30X36 LED 1.8W STANDARD EMERGENCY LIGHT W/ TWO ADJUSTABLE HEADS & BATTERY BACKUP 1.8 WATTS WHITE 34 WATTS LED LED CENTER BASKET TROFFER 2' X 4' C-Lite LED Center Basket Troffer C-TR-A-BT Series | 2' x 2' C-Lite 26 WATTS LED 1 & 3 WHITE WHITE WHITE EXISTING TO REMAIN WALL WHITE 32'-0" 2 X CEILING JOISTS @ 16" O.C. WITH 1/2" GYPSUM BOARD, MECHANICALLY FASTENED TO UNDERSIDE OF STEEL FRAMING. · ALL SCREWS ARE GYPSUM BOARD TYPE “W” OR "S" UNLESS OTHERWISE NOTED AND LONG ENOUGH TO PENETRATE 3/8” INTO FRAMING STEEL. · THE SCREW PATTERN ON THE CEILINGS IS 7" ON CENTER AT THE ENDS · THE SCREW PATTERN ON THE CEILING IS 12” ON CENTER IN THE FIELD. SURFACE MOUNT MULTIPLE JAMB STUD SHH3/68 EACH SIDE OF HEADER EACH W/ (6) #10-16 SCREWS TO JAMB & (6) #10-16 SCREWS TO HEADER LOCATED AS SHOWN BOX HEADER CEILING FRAMING PLAN 1 FLUSH CEILING: CEILING JOIST PERPENDICULAR BEARING ON STUD WALL SCALE: N.T.S. 2 FLUSH CEILING: CEILING PARALLEL TO STUD WALL SCALE: N.T.S. 1000S250-97 50 @ 16" O.C. 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 8" 18'-0" 1000S250-97 50 @ 16" O.C. 10 0 10 0 B B B B B B B SCALE: 1/4' = 1'-0" PROVIDE WEB STIFFENER ON BACK SIDE OF EACH WEB (TYP.) SHEET NUMBER AR 010620 project manager| architect planning design T E L . 4 0 7. 4 2 2. 1 9 9 9 FAX . 1. 866. 8 6 3. 4 3 9 5 T E L . 4 0 7. 4 1 5. 3 2 0 1 F A X . 1. 8 6 6. 3 8 1. 4 5 3 1 r. casey nelson project manager| email: case steve hepner Creative1Desig FORMWORKS CREATIVE architecture email: shepn ATT.Net 2856 W. Fairbanks Ave. Winter Park, FL 32789 NOTICE OF COPYRIGHT: THESE DRAWINGS AND SPECIFICATIONS , IDEAS, DESIGNS AND ARRANGEMENTS REPRESENTED THEREBY ARE; AND SHALL REMAIN THE PROPERTY OF THE DESIGNER, AND NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE DESIGNER. VISUAL CONTACT WITH THESE PLANS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS. WRITTEN DIMENSIONS ON THESE DRAWINGS SHALL HAVE PRECEDENCE OVER SCALED DIMENSIONS. CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE JOB AND THIS OFFICE MUST BE NOTIFIED OF ANY VARIATIONS FROM THE DIMENSIONS AND CONDITIONS SHOWN BY THESE DRAWINGS. SHOP DETAILS MUST BE SUBMITTED TO THIS OFFICE FOR APPROVAL BEFORE PROCEEDING WITH FABRICATION. planning design architect FORMWORKS CREATIVE REFLECTED CEILING PLAN / NOTES / DETAILS A-5 EXCHANGE BUSINESS CENTER 7330 EXCHANGE DRIVE Orlando, FL 32819

Upload: others

Post on 25-Sep-2020

4 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A-5 - LoopNet€¦ · reflected ceiling plan / notes / details a-5 exchange business center 7330 exchange drive orlando, fl 32819. exhaust fan. nutone. 50 cfm ceiling roomside installation

WC

LAV.

D.F.

UTIL

. SIN

KSI

NK

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

WC

LAV.

D.F.

UTIL

. SIN

KSI

NK

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

CEILING KEY NOTES

NOTE : EX I S T ING SPR INKLER HEADS TO BERELOCATED TO ACCOMODATE NEW WALLLOCATIONS. DRAWINGS AND SPRINKLER WORK TOBE PROVIDED BY L ICENSED F IRE SPRINKLERC O N T R A C T O R U N D E R S E P A R A T E P E R M I T .

10 0

SCALE: 1/4' = 1'-0"REFLECTED CEILING PLANNORTH

C1

C2

SURFACE MOUNT

INCLUDED

LED

REFERENCE NOTES: GENERAL NOTES:

8'-6

"8'

-6"

C

A

B

4 - L i g h t 2 f t . x 4 f t . W h i t e H i g hO u t p u t F l u o r e s c e n t H i g h B a y

C

M o d e l # H B L 4 5 4 T 5 H O - L P 4 1( 4 ) T 5 H O 5 4 W 4 1 0 0 K L A M P S I N C L U D E D U N I V E R S A L 1 2 0 - 2 7 7 V I N P U T

M E T A L U X W H I T E W H I T E LED SUSPENDEDAT 22' AFF

C C C C

5'-0" 22'-0" 22'-0" 22'-0" 22'-0" 11'-8"

17'-6

"

C C C CH I G H B A Y H I G H B A Y

H I G H B A YH I G H B A YH I G H B A Y

H I G H B A Y H I G H B A Y

H I G H B A Y H I G H B A Y

1 & 3

1 & 3

1

1

1

OPEN TO UNDERSIDE OF STRUCTURE

REFLECTED CEILING PLAN LEGEND

SYMBOL FIXTURE TYPE MANUFACT. SPECIFICATION FINISH WATTS LAMP MOUNT NOTES

CLEAR 30X36

L E D 1 . 8 W S T A N D A R D E M E R G E N C Y L I G H TW / T W O A D J U S T A B L E H E A D S & B A T T E R Y B A C K U P

1.8 WATTS

W H I T E 34 WATTS LEDL E D C E N T E R B A S K E T T R O F F E R2 ' X 4 '

C - L i t e

L E D C e n t e r B a s k e t T r o f f e rC - T R - A - B T S e r i e s | 2 ' x 2 '

C - L i t e 26 WATTS LED1 & 3

W H I T E

W H I T E

W H I T E

E X I S T I N G T OR E M A I N

WALL

W H I T E

32'-0"

2 X CEILING JOISTS @ 16" O.C. WITH 1/2" GYPSUM BOARD, MECHANICALLY FASTENEDTO UNDERSIDE OF STEEL FRAMING.

· ALL SCREWS ARE GYPSUM BOARD TYPE “W” OR "S" UNLESS OTHERWISE NOTED AND LONG ENOUGH TO PENETRATE 3/8” INTO FRAMING STEEL.· THE SCREW PATTERN ON THE CEILINGS IS 7" ON CENTER AT THE ENDS· THE SCREW PATTERN ON THE CEILING IS 12” ON CENTER IN THE FIELD.

SURFACE MOUNT

MULTIPLE

JAMB

STUD

SHH3/68 EACH SIDE

OF HEADER EACH W/

(6) #10-16 SCREWS TO

JAMB & (6) #10-16

SCREWS TO HEADER

LOCATED AS SHOWN

BOX HEADER

CEILING FRAMING PLAN

1 FLUSH CEILING: CEILING JOIST PERPENDICULAR

BEARING ON STUD WALL

SCALE: N.T.S.

2 FLUSH CEILING: CEILING PARALLEL TO STUD WALL

SCALE: N.T.S.

1000S250-97 50 @ 16" O.C.

1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4" 1'-4"

1'-4

"1'

-4"

1'-4

"1'

-4"

1'-4

"1'

-4"

1'-4

"1'

-4"

1'-4

"1'

-4"

1'-4

"1'

-4"

1'-4

"8"

18'-0

"

1000S250-97 50 @ 16" O.C.

100

100

BB B B

BBB

SCALE: 1/4' = 1'-0"

PROVIDE WEB STIFFENER ON BACKSIDE OF EACH WEB (TYP.)

SHEET NUMBER

AR 010620

p r o j e c t m a n a g e r | d e s i g n e r

architect

planning design

T E L . 4 0 7. 4 2 2. 1 9 9 9 FAX . 1. 866. 8 6 3. 4 3 9 5

T E L . 4 0 7. 4 1 5. 3 2 0 1F A X . 1. 8 6 6. 3 8 1. 4 5 3 1

r. casey nelsonp r o j e c t m a n a g e r | d e s i g n e r

e m a i l : c a s e y @

steve hepner

C r e a t i v e 1 D e s i g n . C o m

FORM

WOR

KSCR

EATIV

E

architecture

e m a i l : s h e p n e r @A T T . N e t

2856 W. Fairbanks Ave.Winter Park, FL 32789

NOTICE OF COPYRIGHT: THESE DRAWINGSAND SPECIFICATIONS , IDEAS, DESIGNSA ND A RRA NGEMENTS REPRESENTEDTHEREBY ARE; AND SHALL REMAIN THEPROPERTY OF THE DESIGNER, AND NO PARTTHEREOF SHALL BE COPIED, DISCLOSED TOOTHERS OR USED IN CONNECTION WITHANY WORK OR PROJECT OTHER THAN THESPECIFIED PROJECT FOR WHICH THEY HAVEBEEN PREPARED AND DEVELOPED WITHOUTTHE WRITTEN CONSENT OF THE DESIGNER.VISUAL CONTACT WITH THESE PLANS ORSPEC IF ICA T IONS SHA LL CONST I TU TECONCLUSIVE EVIDENCE OF ACCEPTANCEO F T H E S E R E S T R I C T I O N S . W R I T T E NDIMENSIONS ON THESE DRAWINGS SHALLH A V E P R E C E D E N C E O V E R S C A L E DDIMENSIONS. CONTRACTOR SHALL VERIFYAND BE RESPONSIBLE FOR ALL DIMENSIONSAND CONDITIONS ON THE JOB AND THISO FF ICE MU S T BE NO T I F I E D OF A NYVARIATIONS FROM THE DIMENSIONS ANDCONDITIONS SHOWN BY THESE DRAWINGS.SHOP DETAILS MUST BE SUBMITTED TO THISO F F I C E F O R A P P R O V A L B E F O R EP R O C E E D I N G W I T H F A B R I C A T I O N .

planning design

architect

FORM

WOR

KSCR

EATIV

E

REFLECTED CEILINGPLAN / NOTES /

DETAILS

A-5

EXC

HAN

GE

BUSI

NES

S C

ENTE

R73

30 E

XCH

ANG

E D

RIVE

Orla

ndo

, FL

328

19

AutoCAD SHX Text
EXHAUST FAN
AutoCAD SHX Text
NUTONE
AutoCAD SHX Text
50 CFM CEILING ROOMSIDE INSTALLATION BATHROOM EXHAUST FAN
AutoCAD SHX Text
DUAL-LITE OR EQUAL
AutoCAD SHX Text
DUAL-LITE OR EQUAL
AutoCAD SHX Text
DUAL-LITE OR EQUAL