a comparative analysis among pwm control z-source inverter with conventional pwm inverter for...
TRANSCRIPT
1
Presented by:
Md. Mustafa Zaved
Department of Electrical and Electronic Engineering
International Islamic University Chittagong
A Comparative Analysis Among PWM Control Z-source Inverter
with Conventional PWM Inverter for Induction Motor Drive
Md. Khurshedul Islam, Md. Mustafa Zaved, Air Mohammad Siddiky
and Khandakar Abdulla Al Mamun
2
Why Inverter for Induction Motor?
• In the last century DC motor widely used in the industries for variable speed application.
• In that times induction motor only used for constant speed application due to unavailability of variable frequency voltage supply.
• But now days, with the development of power electronics, it has made possible to supply variable frequency voltage
• Due to the availability of variable frequency voltage, induction motor has taken the workhorse of the industry because of its robustness, less maintenance, high efficiency & low cost
• There are basically two ways to obtain variable frequency voltage1. Cycloconverter 2. Inverting Process
• Cycloconverter is suitable for large applications, such as locomotives and cement mills
• Inverting process is very much suitable for small & medium application • PWM technique is widely used to vary both frequency & voltage
3
Conventional Inverters for Motor Drive
On the Basis of AC output waveform, conventional inverters are two types1. Current Source Inverter 2. Voltage Source Inverter
Fig2: Basic Circuit Diagram of Conventional VSIFig1: Basic Circuit Diagram of Conventional CSI
Limitations of CSI:• Boost Converter• Possibility of miss gating• Contains more harmonics• Slower dynamic response
Limitations of VSI:• Buck Converter• Possibility of miss gating• Also contains some harmonics• Required additional boost converter
4
Z-Source Inverters for Motor Drive
Advantages of ZSI:• The Source either be voltage or
current source• Provides buck-boost capability• Contains lower harmonics and EMI
noise than conventional
Fig: Basic Circuit Diagram of Z-source Inverter
5
Circuitry Arrangement
Fig1 : Simulation circuit arrangement of CSI for Motor Drive Fig2 : Simulation circuit arrangement of VSI for Motor Drive
Fig3 : Simulation circuit arrangement of VSI for Motor Drive
6
Comparison of Rotor Speed
DriveTorque
CSI VSI ZSI
0 N-m
4 N-m
7 N-m
7
Comparison of Electromagnetic Torque
DriveTorque
CSI VSI ZSI
0 N-m
4 N-m
7 N-m
8
Comparison of Rotor Current
DriveTorque
CSI VSI ZSI
0 N-m
4 N-m
7 N-m
9
Comparison of Stator Current
DriveTorque
CSI VSI ZSI
0 N-m
4 N-m
7 N-m
10
Conclusion
• This paper focus on a comparative analysis of conventional and Z-source inverter for motor drive.
• Z- source fed induction motor provides high starting torque• Quicker operation• Reduces the settling time of rotor and stator currents as
compared to CSI and VSI fed IM.
11
12