a guide to restaurant for hong kong enterprises
TRANSCRIPT
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
1/138
(i)
A GUIDE TO APPLICATION FOR
RESTAURANT LICENCES
Food and Environmental Hygiene Department
(January 2000 Edition)
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
2/138
FOOD AND ENVIRONMENTAL HYGIENE DEPARTMENT
PERFORMANCE PLEDGE
APPLICATION FOR RESTAURANT LICENCES
We are pleased to state below our performance targets in respect of applications for
restaurant licences.___________________________________________________________________________
To help us serve you as we pledge, please :-
z submit your application form together with 3 copies of a proposed layout plan as soon aspossible;
z do not revise the proposed layout plans unnecessarily once submitted;z whenever there are changes to the submitted plans for the application, the applicant is
required to highlight any proposed changes on the revised plans with colour pens and
simple descriptions before making submission to this department for consideration and
referral to other departments for processing. Revised plans not in compliance with this
requirement will be rejected;z inform us of your new correspondence address and contact telephone number should there
be any changes;
z quote your case number and leave your contact telephone number in your correspondencewith us.
Processing Steps
Standard
Response Time
z Return of Proposed Layout Plansfailing the Preliminary Screening
10 working days after the receipt of proposed
layout plans
z Application Vetting Panel Meeting
20 working days from accepting the application
for licence
z Issue of Letter of Requirements(Provisional Licence)
z Issue of Letter of Requirements(Full Licence)
Before or at the Application Vetting Panel
Meeting after confirmation of the premises as
being suitable for licensing
Before or at the Application Vetting Panel
Meeting after confirmation of the premises as
being suitable for licensing
z Final Verification Inspection 8 working days from receipt of report ofcompliance by applicant
z Issue of Full Licence 7 working days from Final VerificationInspection
z Issue of Provisional Licence 7 working days from receipt of acceptablecertificates of compliance (Within 1 working day
if submitted to Licence Issuing Office)
(ii)
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
3/138
(iii)
All correspondence should be addressed to :-
Hong Kong Island
Assistant Secretary (Restaurant Licensing),
Hong Kong Licensing Office,8th floor, Lockhart Road Complex,
225 Hennessy Road, Wan Chai, Hong Kong
ENQUIRY HOTLINES : 2879 5738 or 2879 5717
Kowloon
Assistant Secretary (Restaurant Licensing),
Kowloon Licensing Office,
4th floor, Pei Ho Street Complex,
333 Ki Lung Street, Sham Shui Po, Kowloon
ENQUIRY HOTLINES : 2729 1632 or 2729 1293
New Territories
__________________________________________________________________________
The enquiry hotlines of the following offices of other departments are also useful :-
Office Department Enquiry Hotline
Licensing Unit Buildings Department 2626 1257
Hong Kong Fire Protection Regional
Office
Fire Services Department 2549 8104
Kowloon Fire Protection Regional
Office 2302 5311
New Territories Fire ProtectionRegional Office 2302 5372
Fire Services Department
Fire Services Department
2302 5322 /
2302 5341 /
Ventilation Division Fire Services Department 2718 7567
Assistant Secretary (Restaurant Licensing)
Food and Environmental Hygiene Department
New Territories Licensing Office
4th Floor, Tai Po Complex,No.8 Heung Sze Wui Street, Tai Po, N.T.
ENQUIRY HOTLINES : 3183 9226 or 3183 9227
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
4/138
(iv)
CONTENTS
IMPORTANT ADVICE
DOs and DONTs for Applicants for Restaurant Licences
Part I
GENERAL
Paragraph
1 - 2 Introduction
3 Legislation
4 - 5 General Policy
6 Suitability of Premises
7 Differences between General and Light Refreshment Restaurant Licences
8 Pre-requisites for Issue of a Restaurant Licence
Part II
HOW TO APPLY FOR A RESTAURANT LICENCE
Paragraph
9 Application Form and Proposed Layout Plans
10 What to Be Shown in the Proposed Layout Plans
11 How to Prepare the Proposed Layout Plans
12 Minimum Area for Food Room
13 Location of Food Room
14 Seating Area and Number of Customers
15 - 16 Sanitary Fitments
17 - 18 Choice of Fuel
19 Ablution and Scullery Facilities
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
5/138
20 Utensil Sterilization
21 Staff Changing Rooms/Lockers
Part III
VENTILATION
Paragraph
22 Ventilation
23 Natural Ventilation
24 - 25 Mechanical Ventilating System
26 How to Apply for Approval
27 Window Type Air-conditioners
28 Criteria for Approval
Part IV
THE ROLE OF THE
FOOD AND ENVIRONMENTAL HYGIENE DEPARTMENT
Paragraph
29 Procedures of Processing Application for General/Light Refreshment
Restaurant Licences
30-31 Submission of Application32-33 Preliminary Screening of Layout Plans
34 Separate Site Inspection
35 Application Vetting Panel
36 Issue of Letter of Requirements
37 Refusal
38-39 Report of Compliance
40 Final Verification Inspection
41 Notification of Result to Applicant
(v)
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
6/138
(vi)
Part V
THE ROLE OF THE BUILDINGS DEPARTMENT
Paragraph
42 - 43 The Role of the Director of Buildings
44 Structural Safety
45 Fire Resisting Construction
46 - 47 Means of Escape
48 - 50 Unauthorized Building Works Affecting Public Safety
51 - 52 Application Processing
53 3-tier System for Verification of Compliance with Building Safety
Requirements
Part VI
THE ROLE OF THE FIRE SERVICES DEPARTMENT
Paragraph
54 The Role of the Director of Fire Services
55 How to Obtain a Fire Services Certificate
56 The Procedures
57 Fire Services Requirements
58 - 59 Certificate of Fire Service Installations and Equipment and Certificate of
Compliance (FSI/314A)
60 Dangerous Goods Licence/Letter of Approval
61 Liquid Fuel
62 Solid Fuel
63 - 65 Letter of Compliance (Ventilating System)
66 Catalogue of Emergency Lighting Unit
67 Report of Compliance
68 Follow-up Inspection
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
7/138
(vii)
69 - 70 Issue of a Fire Services Certificate
71 - 72 Re-visit for Non-compliance
Part VII
THE ROLE OF THE ELECTRICAL AND MECHANICAL
SERVICES DEPARTMENT
Paragraph
73 - 75 The Role of the Director of Electrical and Mechanical Services
76 Electricity
77 - 81 Town Gas and LPG
Part VIII
PROVISIONAL RESTAURANT LICENCES
Paragraph
82 Provisional General/Light Refreshment Restaurant Licences
83 - 84 Application and Licensing Procedures
85 - 86 Criteria for Issue
87 Validity
88 - 89 Renewal
90 Transfer
91 Licence Fee
92 - 93 Monitoring
Part IX
ENVIRONMENTAL PROTECTION MEASURES
Paragraph
94 - 95 Environmental Requirements Relating to Restaurants
96 - 107 Important Advice
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
8/138
(viii)
Appendices
Appendix
A Licensing Offices of the Food and Environmental Hygiene
Department
B List of Approved Food Items for Light Refreshment Restaurants
C Application Form for Restaurant Licence
D Samples of Layout Plans
E One-stop Shop Offices of the Environmental Protection Department
F Standard Requirements and Conditions for Ventilating (Air-
conditioning) System
G Flow Chart Showing Restaurant Licensing Procedures
H Restaurant Licence Application Quality Audit Result Report
I Standard Requirements and Conditions for Full General Restaurant
Licence
J Standard Requirements and Conditions for Full Light Refreshment
Restaurant Licence
K List of Unauthorized Building Works Affecting Public Safety
L Categorisation of Typical Building Safety Issues
M Fire Protection Regional Offices and Ventilation Division of the Fire
Services Department
N Samples of Certificate/Licence/Letter Required by the Fire Services
Department
O The Electrical and Mechanical Services Department
P Health and Ventilation Requirements for the Issue of Provisional
General/Light Refreshment Restaurant Licence
Q Report of Compliance for the Grant of Provisional General/Light
Refreshment Restaurant Licence
R Certificate of Compliance A (Health Requirements)
S Certificate of Compliance B (Building Requirements)
T Certificate of Compliance C (Fire Services Requirements)
U Certificate of Compliance D (Ventilation Requirements)
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
9/138
(ix)
IMPORTANT ADVICE
DOs & DONTs for Applicants for
Restaurant Licences
DOs
DO choose premises whose use is suitable for operating restaurant business under the
occupation permit, the Government Lease and the relevant statutory town plan
DO choose premises in which there are no unauthorized building works by cross
reference to the approved building plan.
DO choose premises with nett floor areas preferably not less than 30m
2
and 20m
2
respectively for a general restaurant and a light refreshment restaurant.
DO choose premises on floors with adequate loading capacity.
DO choose premises with adequate means of escape.
DO choose premises with mains water supply, flushed toilets and a proper drainage
system.
DO choose premises capable of providing an independent and separate ventilating
system to the kitchen, toilets and seating accommodation.
DO prepare three copies of layout plans and air-conditioning/ventilation layout
plans of the proposed premises drawn to scale (of not less than 1:100) and in
metric units for submission together with your application to the appropriate
licensing office.
DO note the relevant requirements in respect of drainage, air pollution and noise
control as stipulated in the relevant ordinances.
DO appoint an authorized person or registered structural engineer where extensivealteration and additional works are to be carried out or if you are unfamiliar
with any of the foregoing requirements.
DONTs
DONT choose premises at industrial buildings.
DONT choose the upper floors of any premises which are designed for domestic use.
DONT choose premises at level four of a basement or below.
and the notes attached thereto.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
10/138
(x)
DONT choose premises in areas designated for emergency use.
DONT choose premises located vertically below, therefore posing a fire hazard to, a
registered school, child care centre or elderly home.
DONT choose premises on the upper floors of single staircase buildings.
DONT plan to use the areas where manholes or soil, waste and rain water pipes are
situated as kitchens, food preparation rooms and sculleries.
DONT start renovating or decorating your premises before your application has been
cleared by the Application Vetting Panel.
DONT revise the proposed layout plans unnecessarily after your application has beencleared by the Application Vetting Panel. Revision will cause delay in the
processing of your application.
DONT commence business before a licence is obtained from the Licensing Authority.
DONT ignore the requirements imposed by other Government departments including
the Buildings Department, the Fire Services Department, the Electrical and
Mechanical Services Department and the Environmental Protection
Department notwithstanding that a licence has been granted by the Licensing
Authority.
IMPORTANT NOTICE
It is an offence under the Prevention of Bribery Ordinance to offer
advantages to Government officers.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
11/138
1
Part I
GENERAL
Introduction
The purpose of this Guide is to provide general information to assist members of thepublic in their applications for general and light refreshment restaurant licences as well as for
provisional general and light refreshment restaurant licences under the Public Health and
Municipal Services Ordinance (Chapter 132 of the Laws of Hong Kong), Regulations 31(1)(b)
and 33C of the Food Business Regulation (both of the same Chapter 132 of the Laws of Hong
Kong) and other relevant legislation. It aims to set out the normal requirements for the issue
of such licences and should be read by those interested in establishing restaurant business in
Hong Kong. Although every attempt has been made to ensure that it is complete and up-to-
date, revision may be made from time to time. For enquiries, please contact the Licensing
Offices of the Food and Environmental Hygiene Department*.
2. Any person who intends to sell or supply liquor in connection with his restaurant
business on any premises for consumption therein in Hong Kong must obtain a liquor licence
issued by the Liquor Licensing Board before commencement of such business. Guidance
booklets on application for liquor licences are obtainable at the Licensing Offices of the Food
and Environmental Hygiene Department*.
Legislation
3. The Director of Food and Environmental Hygiene Department is the Licensing
Authority of restaurants in Hong Kong and the legislation as mentioned in paragraph 1 above
stipulates the control of such establishments. Under the legislation, a restaurant operator isrequired to obtain a restaurant licence from the Licensing Authority before operation of
business. Any person found operating an unlicensed restaurant and/or violating the relevant
provisions in the legislation will be liable to prosecution.
General Policy
4. The purpose of licensing restaurants is to safeguard public health and to ensure the
safety of patrons. The Licensing Authority will not consider an application for a restaurant
licence in respect of any premises unless such premises :-
(a) can meet stringent health requirements;
(b) have adequate ventilation;
(c) can meet structural requirements;
(d) do not have unauthorized building works affecting public safety;
(e) have adequate means of escape; and
(f) can meet fire services requirements.
__________________________________________________________________________
* The addresses and telephone numbers of the Licensing Offices of the Food and Environmental
Hygiene Department are at Appendix A.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
12/138
2
It is also the Licensing Authoritys established policy not to issue restaurant licences to the
upper floors of any premises which are designated for domestic use, to avoid causing
nuisances to inhabitants.
5. In deciding on the suitability of premises for use as a restaurant, the Food and
Environmental Hygiene Department consults the Buildings Department and the Fire Services
Department. If their comments are such that its policy cannot be complied with, thelicensing authority will refuse the application and inform the applicant of the refusal with
reasons. The Food and Environmental Hygiene Department will normally continue to
process an application only when the premises are deemed to be safe and suitable by the Food
and Environmental Hygiene Department, the Buildings Department and the Fire Services
Department.
Suitability of Premises
6. Not all premises are suitable for licensing as restaurants. The following
summarizes the main considerations involved :-
(a) Health (Food and Environmental Hygiene Department)
(i) Premises are laid on with mains water supply.
(ii) Premises are provided with a proper drainage system.
(iii) Premises are provided with proper flushed toilets.
(iv) No manholes should be located in the proposed kitchen, food
preparation room and scullery.
(v) Premises are capable of providing an independent and separate
ventilating system to the kitchen, toilets and seating accommodation.
(b) Building Safety Requirements (Buildings Department)
(i) A restaurant shall not be situated in premises other than those approved
for non-domestic use, unless no objection is raised by the Buildings
Department.
(ii) The Buildings Department will not recommend to the Licensing
Authority to issue a restaurant licence if unauthorized building works
which pose risks to public safety are found on the premises under
application.
(iii) The minimum designed loading of the premises shall not be less than5 Kpa (i.e. 100lbs/ft2).
(iv) Where alteration and addition works involving the structure and/or
means of escape of a building are to be carried out, formal submission
of plans for the proposed works to the Buildings Department by an
Authorized Person (AP) and/or Registered Structural Engineer (RSE)
may be required. It is strongly recommended that the advice of an AP
or RSE should be sought well in advance.
(v) Premises shall be designed and constructed of fire resisting materials
which satisfy the provisions of the Building (Construction) Regulations
and the Code of Practice for Fire Resisting Construction 1996 issued by
the Buildings Department.(vi) Every restaurant shall be provided with adequate means of escape in
accordance with Part V of the Building (Planning) Regulations and the
Code of Practice for the Provision on Means of Escape in case of Fire
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
13/138
3
1996 (MOE Code) issued by the Buildings Department.
(vii) For premises on the ground floor having direct access to a street, there
would generally be no major problem on means of escape provision.
For premises on upper storeys and basements, at least two escape
staircases are required for the restaurant.
(viii) Restaurants are not permitted to operate on the upper floors of single-
staircase buildings.(ix) The provision of means of escape in any particular floor of a building
or in the building as a whole can only accommodate a specified
maximum number of persons at any one time. The current MOE
Code sets out such limits and relates them to the width and number of
exit routes provided for each floor and for the whole building. It
follows that if, as a result of the operation of a restaurant, the existing
population figure for a floor or for the building exceeds these limits, a
recommendation for rejection of the application will be made. In
assessing the population figures, applications in respect of premises
located within the same building will be treated on a first-come-first-
served basis.
(c) Fire safety (Fire Services Department)
The following premises are considered not suitable to be licensed as
restaurants :-
(i) Any industrial buildings;
(ii) Any buildings or structures which are of substandard construction;
(iii) Premises at level four of a basement or below;
(iv) Premises in areas designated for emergency use, such as the bufferfloor (also referred to as the refuge floor); and
(v) Premises located vertically below, therefore posing a fire hazard to, a
registered school, child care centre or elderly home. (However,
consideration would be given to those where such fire hazard can be
mitigated.)
Differences between General and Light Refreshment Restaurant Licences
7. The differences between the General and Light Refreshment Restaurant Licences
are as follows :-
(a) General Restaurant Licence
This licence permits the licensee to prepare and sell any kind of food for
consumption on the premises.
(b) Light Refreshment Restaurant Licence
This licence restricts the licensee to prepare and sell for consumption on the
premises any one group of the food items shown in Appendix B.
As light refreshment restaurant licences are intended for the preparation of a limited range offood items, the requirements for this type of restaurants in the context of the minimum area
for food room (i.e., kitchen, food preparation room and scullery) are less stringent than those
for general restaurants. Details of the minimum area requirements for food room are set out
See
Appendix B
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
14/138
4
in paragraph 12. Failure to apply for the correct type of restaurant licences may result in
delay in or rejection of the licence application.
Pre-requisites for Issue of a Restaurant Licence
8. Under the Food Business Regulation, the licensing authority will not issue a
restaurant licence until the following pre-requisites are fulfilled :-
(a) compliance with licensing requirements in respect of health, ventilation, gas safety,
building structure and means of escape imposed by Licensing Authority; and
(b) compliance with fire services requirements imposed by the Director of Fire
Services.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
15/138
Part II
HOW TO APPLY FOR A RESTAURANT LICENCE
Application Form and Proposed Layout Plans
9. Application for a restaurant licence may be made in the name of a person or a
corporation and submitted either on a standard form*, or by letter in which case it must
contain the particulars included in the standard form, to the relevant Food and Environmental
Hygiene Department Licensing Office. Standard application forms are obtainable at all the
Food and Environmental Hygiene Department Licensing Offices and District Offices
(Environmental Hygiene) or can be downloaded from the website of the Food and
Environmental Hygiene Department at http://www.fehd.gov.hk/english/forms/licence.html.
The application form must be submitted together with three copies of the proposed layout
plans of the restaurant. Such plans must be drawn to scale (of not less than 1:100), in metric
units and signed by the applicant on all copies to certify that they are correct. Should the
respective Food and Environmental Hygiene Department Licensing Office find the plansincomplete and unacceptable, the applicant will be advised to re-submit revised plans.
What to Be Shown in the Proposed Layout Plans
10. The proposed layout plans should contain the following particulars :-
(a) space allocated to the cooking, preparation and handling of food;
(b) space allocated to the storage of any kind of exposed food;
(c) space allocated to the serving of meals to customers;
(d) space allocated to the cleansing, sterilizing, drying and storage of utensils;(e) sanitary fitments and drainage works;
(f) cloak rooms, passageways and open spaces;
(g) all means of exit, entry and internal circulation;
(h) all windows, ducts providing ventilation and means of mechanical ventilation;
(i) the siting of all furniture and equipment of a substantial and permanent nature,
including food manufacturing and preparation plant, cooking ranges, sterilizers,
dish-washing machines, refrigeration and cooling equipment, fixed sideboards,
washbasins and sinks, drying racks and water tanks;
(j) means of refuse storage and disposal;
(k) the type of fuel to be annotated. If liquid fuel is used, the location of the fueltank and its capacity should be indicated on the layout plan;
(l) the extent of raised floor should be indicated; and
See
Appendix D
(m) fire services details in paragraph 56.
Samples of proposed layout plans (both Chinese and western restaurants) are at
Appendix D for general reference.
____________________________________________________________________
* A copy of the application form is at Appendix C.
The addresses and telephone numbers of the Licensing Offices are at Appendix A.- 5 -
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
16/138
6
How to Prepare the Proposed and Revised Layout Plans
11. Paragraphs 12 to 21 hereunder give some general guidance on how to prepare the
proposed layout plans. The licensing authority may consider exemptions for genuine cases
on individual merits. Whenever there are changes to the submitted plans for the application,
the applicant is required to highlight any proposed changes on the revised plans with colour
pens and simple descriptions before making submission to this department for consideration
and referral to other departments for processing. Revised plans not in compliance with thisrequirement will be rejected.
Minimum Area for Food Room
12. In preparing the proposed layout plans, the first thing to be considered is the size
of the food room(s) (i.e., kitchen, food preparation room and scullery accommodation).
According to the Fifth Schedule to the Food Business Regulation, every general or light
refreshment restaurant is required to be provided with a food room, the area of which is as
follows :-
(a) General Restaurants
Gross floor area
of the premises in
m2
Minimum kitchen area in m2 Minimum aggregate area of
kitchen, food preparation room
and scullery accommodation in m2
100 or less 6 30% of gross floor area, but not
less than 9m2
101-150 10 25% of gross floor area, but not
less than 27m2
151-250 10 23% of gross floor area, but not
less than 36m2
251 or above 14 21% of gross floor area, but not
less than 54m2
(b) Light Refreshment Restaurants
Gross floor area of the
premises in m2 22 or less
Minimum aggregate area of kitchen, food preparation
room and scullery accommodation in m2Not less than
5m2
23-35 20% of gross floor area or 7m2 , whichever is the less
36-5518% of gross floor area or 8m2 , whichever is the less
56-9514% of gross floor area or 12m2 , whichever is the less
96-18513% of gross floor area or 17m2 , whichever is the less
186 or above 9% of gross floor area or 28m2 , whichever is the more
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
17/138
7
The gross floor area is the covered area used exclusively for the business of the restaurant
including store-rooms, cold storage chambers, staff changing rooms, offices, air-conditioning
plant rooms, lavatories, lift lobbies, stair halls. It should be measured to inside of boundary
walls including columns, if any, within the area to be licensed and does not include any yard
or open space. (In the calculation of food room(s) and seating areas, only nett usable floor
space (measured to internal walls) and space having 1.8m high or more headroom will be
taken into consideration; however, columns, if any, will be excluded.)
Location of Food Room
13. In designing the food room(s), care should be taken to avoid placing them at
locations where there are manholes or foul-waste/sanitary fitments (water closets, urinals and
toilets.). Resiting of the manholes and/or drainage alterations may require the approval of
the Buildings Department. Furthermore, the food room(s) should not be so designed as to
result in :-
(a) the conveyance of food or clean eating utensils from the food room(s) to the
customers seating area through an open space or open yard; or
(b) customers having to pass through the food room(s) when going to toilets.
Failure to meet these requirements may constitute an objection to the proposed layout of the
restaurant on health grounds.
Seating Area and Number of Customers
14. After the size of the food room(s) has been decided, the seating area for customers
can be marked out on the plans. The seating area should normally include passages. Forthe purpose of calculating the number of sanitary fitments required (paragraph 15) and the
volume of outside air required on the premises per hour if a ventilating system is to be
installed (paragraph 25), the number of customers to be accommodated is calculated at 1.5m2
per person of the seating area provided.
Sanitary Fitments
15. The number of sanitary fitments required in both general and light refreshment
restaurants is the same, and varies with the number of customers and staff to be
accommodated. The requirements are as follows (where WC denotes water closet; WHBdenotes wash-hand basin and U denotes urinal) :-
(a) Less than 25 customers )
1 WC and 1 WHB For both sexes )
1 U For males )
(WCs and Us should be
provided in separate rooms with
separate entrances.)
) Provision of
) sanitary
) fitments for
) staff is exempted.
(b) Between 25 and 100 customers )
1 WC, 1 WHB and 1 U For males )1 WC and 1 WHB For females )
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
18/138
8
(c) Between 101 and 200 customers
)
1 WC, 1 WHB and 2Us For males )
2 WCs and 1 WHB For females ) Provision of
) sanitary
(d) Between 201 and 300 ) fitments for 2 WCs, 2 WHBs and 3 Us For males ) staff is exempted.
3 WCs and 2 WHBs For females )
(e) Over 300 customers
Provision of sanitary fitments for customers and staff should conform to the
requirements in regulations 5 and 8 of the Building (Standards of Sanitary
Fitments, Plumbing, Drainage Works and Latrines) Regulations, Cap. 123.
16. The internal dimensions of each toilet compartment should not be less than 700 mm
x 1,200 mm. If a trough urinal is installed, 500 mm of trough length is deemed equivalent to
one stall urinal. Each urinal should have a user standing space of not less than 500 mm x
500 mm in front of it. In case where a urinal compartment is provided, the minimum
internal dimension of the compartment should not be less than 1000 mm (depth) and 500 mm
(width). If the proposed restaurant is situated in a commercial building and sanitary fitments
are not provided within the premises, communal toilets in the building allotted for the
exclusive use of customers and staff of the restaurant may also be accepted for consideration
in the application for a restaurant licence. In this regard, labels should be affixed to the
appropriate sanitary fitments to indicate the specific use of the toilets by the restaurant staff
and patrons and the labels should be placed in a visible position. Furthermore, a certified
toilet block plan and toilet allocation certificate (or remote toilet letter) in connection with the
application with the use of the allocated toilets should be furnished to the Licensing Authority.
Choice of Fuel
17. The use of fuel is subject to control by the Fire Services Department and the
Electrical and Mechanical Services Department. Applicants are advised to read paragraphs
61 and 62 in Part VI and paragraphs 76 to 81 in Part VII before deciding on the type of fuel to
be used. From air pollution point of view, gaseous fuel should be used. Liquid and solid
fuels are not recommended due to the associated dark smoke and other air pollution problem.
The use of fuel has an important bearing on the design of the layout of a restaurant.Generally, for service bars (soda fountains and bar counters) which are not enclosed with
walls having a fire resisting period of not less than one hour, electricity, town gas and piped
liquefied petroleum gas are normally allowed. For kitchens which are enclosed with the
aforesaid walls and provided with fire resistant doors, any kind of fuel may be used subject to
compliance with Fire Services requirements as well as those requirements stipulated by the
Director of Electrical and Mechanical Services in respect of electricity, town gas and liquefied
petroleum gas. Furthermore, the applicant is required to obtain prior approval from the
Environmental Protection Department if there is any installation or alteration of restaurant
stoves or its chimney/exhaust inside premises with the total fuel consumption capacity,
including that of the proposed work, exceeding:
(a) 25 litres of conventional liquid fuel per hour; or
(b) 35 kilograms of conventional solid fuel per hour; or(c) 1,150 megajoules of any gaseous fuel per hour.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
19/138
9
The application for prior approval should be submitted to the one-stop shop
offices of the Environmental Protection Department* not less than 28 days prior to the
commencement of such work.
18. The Licensing Authoritys requirements in respect of fuel is that if the
applicant proposes to use diesel oil or solid fuel, an independent chimney above theroof level will have to be provided. The construction of the chimney should meet the
requirements of both the Buildings Department and the Environmental Protection
Department. The position of the chimney should be indicated on the proposed layout
plans.
Ablution and Scullery Facilities
19. Food handlers should always keep their hands clean. For every single food
room (i.e., kitchen, food preparation room and/or scullery), there must be at least one
wash-hand basin and one wash up sink for use by staff. For a large food room which
accommodates a large number of staff, the standard of provision of wash-hand basinsis one basin for every 20 staff. The length of such basin and sink should not be less
than 350mm and 450mm respectively measured from the top inner edges of the rims.
It is an offence against the Food Business Regulation to wash eating utensils or food
equipment in open spaces. Applicants are strongly advised to provide adequate space
and sinks for the washing and cleaning of eating utensils according to their
operational needs.
Utensil Sterilization
20. Used eating utensils must be washed and sterilized before re-use. Failure
to observe this rule is in breach of the Food Business Regulation. On the proposed
layout plans, the position of the sterilizer for eating utensils must be indicated. The
alternative use of an approved type of bactericidal agent for sterilizing eating utensils
instead of boiling is permitted. Approved dish washing machines having a
sterilization function may be used in lieu of a conventional sterilizer. Lists of such
approved types of bactericidal agents and dish washing machines may be obtained
from the Food and Environmental Hygiene Department Licensing Offices.
Staff Changing Rooms/Lockers
21. It is an offence against the Food Business Regulation to place personaleffects or garments in any food room(s) as they will contaminate food. For restaurants
having a large number of staff, provision of a changing room for them is advisable.
For smaller restaurants, there should be adequate lockers for storage of employees
personal effects. The lockers should not be located in the food room(s) and their exact
positions should be indicated on the proposed layout plans. Access to the changing
rooms and lockers should not be through the food room(s).
* The addresses and telephone numbers of these offices are at Appendix E.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
20/138
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
21/138
11
(f) the nett area of exhaust in square metres except where the premises are air-
conditioned with positive pressure; and
(g) the type of refrigerant to be used*.
The proposed layout plans of the ventilating system must be drawn to scale (of not less than
1:100), in metric units and the applicant must sign on each copy to certify that it is correct. Ifthe proposed restaurant is in a shopping arcade, the applicant needs to provide three copies of
the ventilating system block plan.
Window Type Air-conditioners
27. For small restaurants which use only window type air-conditioners and
propulsion/extraction fans, the applicant may himself prepare such simple ventilation plans
showing the locations of the installations and submit them in triplicate together with the
licence application to the respective Licensing Office of the Food and Environmental
Hygiene Department. The manufacturers catalogues of the air-conditioners and
propulsion/extraction fans must also be submitted to enable the licensing inspector to obtain
the technical data of these appliances for the processing of the application. In the event that
the catalogues do not provide the necessary data, the applicant may be required to obtain
certification of the required data from the manufacturer or supplier of the appliances.
Criteria for Approval
28. Upon receipt of an application for approval of a proposed ventilating system, the
relevant Food and Environmental Hygiene Department Licensing Office will forward the
application and a copy of the ventilation plans to the Fire Protection (Fire Safety) Command
(Ventilation Division) of the Fire Services Department for action. Where structural safetyrelated to the ventilating system is involved, a copy of the plans will also be forwarded to the
Buildings Department. If there is no objection on health grounds, the Food and
Environmental Hygiene Department will issue a letter of ventilation requirements (Appendix
F) together with the fire safety requirements on mechanical ventilating systems of the Fire
Services Department to the applicant. Paragraphs 63 to 65 in Part VI describe how the Fire
Protection (Fire Safety) Command (Ventilation Division) will process the application.
Subject to compliance with the requirements imposed by the Food and Environmental
Hygiene Department and the issue of a Letter of Compliance (Ventilating System) by the Fire
Services Department, approval for the ventilating system may then be granted. Late
submission of ventilation plans may cause delay in issue of licence. Applicants are advisedto submit applications as early as possible.
___________________________________________________________________________
* Please seek expert advice on the type of refrigerant permitted for various installations.
See
Appendix F
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
22/138
Part IV
THE ROLE OF THE
FOOD AND ENVIRONMENTAL HYGIENE DEPARTMENT
Procedures of Processing Application for General/Light Refreshment Restaurant
Licences
See
Appendix G29. The flow chart at Appendix G shows the procedures of processing an application for
General/Light Refreshment Restaurant Licences and the contents of this part and Parts V to VII
are to describe the procedures in detail.
Submission of Application
30. Applicants should send the completed application form* or letter together with the
proposed layout plans as detailed in Part II in triplicate to the relevant Food and Environmental
Hygiene Department Licensing Office.
31. Upon receipt of the application, the Food and Environmental Hygiene Department
will send a copy of each of the completed application form to the Buildings Department and
the Fire Services Department for comment.
Preliminary Screening of Layout Plans
32. The Case Manager of the appropriate Licensing Office of the Food andEnvironmental Hygiene Department will conduct a preliminary screening of plans to ensure
that the application and layout plans conform to the requirements before it is processed further.
33. The applicant will be informed of whether his proposal has met the requirements.
He will also be given advice as to how any shortcomings can be overcome. If the application
is not accepted, the unacceptable proposed plans will be returned to the applicant within 10
working days.
Separate Site Inspection
34. A copy of the proposed layout plan will be referred by the Food and Environmental
Hygiene Department to both the Buildings Department and the Fire Services Department for
comments. The officers of the three departments concerned will conduct separate site
inspections to the premises with the applicant and/or his representatives. Site inspections will
allow the departments concerned to come to an initial view as to whether or not the premises
are suitable for the operation of a restaurant and to give general advice within their respective
ambits.
*A copy of the application form is at Appendix C
The address and telephone numbers of the Food and Environmental Hygiene Department Licensing Offices are at
Appendix A
12
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
23/138
Application Vetting Panel
35. After the separate site inspections, an Application Vetting Panel meeting will be
arranged, normally within twenty working days after the acceptance of the application, in
which the applicant (and his authorized person/registered structural engineer if appointed) can
discuss his application with officers of all the three departments concerned. Problem areas,remedial works and the applicants proposed construction/decoration programmes will be
discussed. In the event that there are, for whatever reasons, impediments to licensing, he will
be so informed and if remedies are feasible, advice will be given.
Issue of Letter of Requirements
36. After full clearance from the departments concerned at the Application Vetting Panel
meeting, the Food and Environmental Hygiene Department will issue a letter of requirements
to the applicant listing the licensing requirements (Appendices F and I/J as appropriate). Fire
safety requirements will be issued by the Fire Services Department separately. The applicant
is advised to report to the respective Licensing Office of the Food and Environmental Hygiene
Department for verification as soon as he has complied with all the requirements.
See
Appendices
F,I & J
Refusal
37. In the event that the premises are deemed to have serious impediments and remedies
are considered not feasible by the Application Vetting Panel, the Licensing Authority may
consider refusing the application.
Report of Compliance
38. The applicant should expedite action to comply with the licensing requirements and
to report compliance as soon as possible to the respective Food and Environmental Hygiene
Department Licensing Office for verification. If no report of compliance is received, the Case
Manager will only inspect the premises at three months intervals to check progress of
compliance. If evidence suggests that the applicant takes no effort to comply with the
licensing requirements within six months, the Licensing Authority may consider revoking the
application.
39. After receipt of the applicants letter reporting compliance, the Case Manager will
make an appointment with the applicant to inspect the premises and check the licensing
requirements. If there are still outstanding licensing requirements, these will be pointed out to
the applicant during the inspection, and thereafter, the applicant will be advised in writing that
he has to report compliance after he has complied with the outstanding requirements, so that
another verification inspection can be arranged.
13
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
24/138
14
Final Verification Inspection
40. When full compliance with the licensing requirements is confirmed by the Senior
Health Inspector (Restaurant Licensing), a Chief Health Inspector (Restaurant Licensing) will
conduct the final verification inspection (normally within ten working days after report of
compliance by the applicant) in the presence of the applicant.
Notification of Result to Applicant
41. After the final verification inspection, the Assistant Secretary (Restaurant Licensing)
will inform the applicant in writing of full compliance with the licensing requirements and of
the arrangements regarding the payment of prescribed fee* and collection of the licence.
__________________________________________________________________________
* A list of the prescribed fees in respect of restaurant licences is available at the Food andEnvironmental Hygiene Department Licensing Offices the addresses and telephone numbers of
which are at Appendix A.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
25/138
15
Part V
THE ROLE OF THE BUILDINGS DEPARTMENT
The Role of the Director of Buildings
42. The Director of Buildings offers advice on applications for restaurant licences to theFood and Environmental Hygiene Department in regard to the suitability of premises in the
following areas:
(a) Structural safety;
(b) Fire resisting construction;
(c) Means of escape; and
(d) Unauthorized building works affecting public safety.
43. General Requirements:
(a) Each case shall be considered on its merits after full consideration of the
circumstances. Nothing contained herein shall be taken as in any way
derogating from the powers of the Director of Buildings under the
Buildings Ordinance, Cap. 123 and its subsidiary regulations.
(b) As the subject matters are often related to complicated technical issues
which may be difficult to overcome, the applicant is strongly advised to
enlist the service of an Authorized Person (AP) (architect, engineer or
surveyor) at the early stage to avoid unnecessary waste of time and efforts
resulting from unsuccessful applications.
(c) Where alteration and addition works involving the structure and/or means
of escape of a building are to be carried out, formal submission of plans
for the proposed works to the Buildings Department by an AP and/or
Registered Structural Engineer (RSE) may be required. It is strongly
recommended that the advice of an AP or RSE should be sought well in
advance. A Directory of AP and RSE registered under the Buildings
Ordinance are available in the Buildings Department for viewing.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
26/138
Structural Safety
44. The main issues to be considered on structural safety are:
(a) The minimum designed loading of the premises shall not be lessthan5 Kpa (i.e. 100lbs/ft2).
(b) In cases where there are non-structural screeding on slabs to raisefloors levels, heavy kitchen equipment/plant, fish tanks or
brick/partition walls, justification of the adequacy of the existing
floor to cater for such superimposed loads will have to be
submitted by an AP/RSE. In this connection, the size of the cold
storage room/walk-in-freezer should be commensurate with the
food premises with reasonable internal circulation area. The size
and clear height of the cold storage room/walk-in-freezer and
storage racks and the layout of the racks should be indicated on the
plan. The supporting structural calculations should be based on
5Kpa for each metre of storage height and 2Kpa for internal
circulation area and taken into account the weight of the storage
racks, evaporators and enclosures (including any superimposed
load on the top).
(c) No part of a restaurant shall be located in, under or over anystructures built without the approval and consent of the Buildings
Department.
(d) A restaurant shall not be situated in premises other than thoseapproved for non-domestic use, unless no objection is raised by the
Buildings Department.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
27/138
16
Fire Resisting Construction
45. Premises shall be designed and constructed of fire resisting materials which satisfy
the provisions of the Building (Construction) Regulations and the Code of Practice for Fire
Resisting Construction 1996 issued by the Buildings Department. General requirements onfire resisting construction include:
(a) Restaurant premises shall be separated from the adjoining occupancy by
walls and floors having a fire resistance period (FRP) of not less than 1
hour. For a restaurant situated in a shopping arcade, such separation is
normally not required between the restaurant and the arcade.
(b) Hot-pot restaurants shall be separated from adjoining premises by walls
and floors having an FRP of not less than 1 hour and any door openings
on such walls should be provided with self-closing doors of not less than
hour FRP. A protected lobby should be provided between each door
of the restaurant and any escape route of the building.
(c) The kitchen of a restaurant should be enclosed by walls and floors having
an FRP of not less than 1 hour and any opening in the enclosure should be
defended by a door having an FRP of not less than hour. A protected
lobby should be provided between each door of the kitchen and
- any escape route from the main building; and/or
- the dining area of the restaurant where the kitchen has a usable floor
area exceeding 45m2 and the door opens onto an exit route of thedining area.
(d) Food hatch formed on the enclosure wall of the kitchen shall be protected
by fire shutter having an FRP of not less than hour.
(e) Openings for passage of air-conditioning ducts through fire resisting
walls such as kitchen wall should be properly protected by fire dampers in
order to maintain the FRP of that wall.
(f) In cases where new fire resisting walls and doors are involved, a dulycompleted Form (Appendix A to the Practice Note for Authorized
Persons and Registered Structural Engineers No. 53) from an AP/RSE
shall be submitted to substantiate the FRP of the fire resisting
components.
Means of Escape
46. Every restaurant shall be provided with adequate means of escape in accordancewith Part V of the Building (Planning) Regulations and the Code of Practice for the Provision
on Means of Escape in case of Fire 1996 (MOE Code) issued by the Buildings Department.
47. The provision of means of escape in any particular floor of a building or in the
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
28/138
17
building as a whole can only accommodate a specified maximum number of persons at any
one time. The current MOE Code sets out such limits and relates them to the width and
number of exit routes provided for each floor and for the whole building. It follows that if,
as a result of the operation of restaurant, the existing population figure for a floor or for the
building exceeds these limits, a recommendation for rejection of the application will be made.
In assessing the population figures, applications in respect of premises located within the
same building will be treated on a first-come-first-served basis. The general requirementsare listed below:
(a) For premises on the ground floor having direct access to a street, there
would generally be no major problem on means of escape provision.
For premises on upper storeys and basements, at least two escape
staircases are required for the restaurant. Restaurants are not permitted
to operate on the upper floors of single-staircase buildings.
(b) Any room with a capacity exceeding 30 persons shall be provided with at
least 2 exits. The exit doors shall open in the direction of exit and shall
not obstruct any part of the exit route by the swing of the doors.
(c) Normally, the minimum width of an exit route shall be not less than
1050mm and greater width would be required depending on the total
capacity of the restaurant. The exit doors shall have a minimum width
of not less than 750mm for capacity of 30 persons or less; and 850mm for
capacity between 31-200 persons with a total width of 1750mm.
Reference should be made to MOE Code for the detailed requirements.
(d) All required exit routes shall lead directly to a street and the staircase
enclosure at G/F shall be so continued at G/F as to separate from theremainder of the building. All exit routes shall have a clear height of
not less than 2m and be kept free from obstruction. Every part of each
exit route shall be provided with adequate artificial lighting and backed
up by an emergency lighting system providing a horizontal illuminance at
floor level of not less than 2 lux. The design of the emergency lighting
system shall comply with the Code of Practice for Minimum Fire Service
Installations and Equipment.
(e) All exit doors shall be capable of being readily opened from the inside
without the use of a key. Auto sliding doors shall remain in an openposition during power failure.
(f) Security shutters across exits must be kept open during business hours.
(g) A solid separation of 450mm should be provided between the shopfront
of a restaurant and the final discharge point of an exit staircase of a
building.
(h) Where the direction of travel from an exit door of a room to a staircase is
possible in one direction only (i.e. dead-end), the distance from any part
of a room to an exit or a point, from which travel in different directions to2 or more exits are available, shall not exceed 18m. In other cases
where alternative exit routes are available in more than one direction, it
may vary from 30m to 45m, depending on the fire resisting construction
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
29/138
18
of the exit routes.
(i) For the purpose of determining the adequacy of means of escape, actual
counting of the population may be acceptable. In normal circumstances,
the population of the premises is assessed as follows:
Use Factor used in determining the population
Seating Area 1 m2/person
Food Room Area 4.5 m2/person
Dancing Area 0.75 m2/person
Unauthorized Building Works Affecting Public Safety
48. The existence of unauthorized building works on or affecting premises underapplication for restaurant licences may pose a risk to the safety of the restaurant employees
and patrons. The Buildings Department will not recommend to the Licensing Authority to
issue a restaurant licence if unauthorized building works, particularly unauthorized cockloft,
slabbing-over of original staircase opening and cockloft void, which pose risks to public
safety are found on the premises under application. Applicants are therefore advised to
exercise extreme care in selecting premises for restaurant use, as the presence of unauthorized
building works may render the premises unsuitable for restaurant licensing. If the premises
selected for restaurant use contains unauthorized building works, the applicant is strongly
advised to effect removal of such works before submitting an application for licence.
49. (a) A list of unauthorized building works affecting public safety is provided forthe reference of applicants at Appendix K.
(b) The erection of advertising signs should be in accordance with the "Guide on
Erection and Maintenance of Advertising Signs" issued by the Buildings
Department. In general, advertising signs projecting over a pavement should
have a minimum vertical clearance of 3.5m and a minimum horizontal
clearance of 1.0m from the curb of such pavement. Advertising signs
projecting over a carriageway should have a minimum vertical clearance of
5.8m. Copies of the Guide can be obtained from the Buildings Department
for reference.
50. The applicants attention is drawn to the Disability Discrimination Ordinance in
regard to the provision of access and facilities for persons with a disability. Unauthorized
removal or alteration of existing approved access and facilities (e.g. ramps, toilets, etc.) for
persons with a disability may be subject to enforcement and prosecution actions under the
Buildings Ordinance.
Application Processing
51.
Through arrangements by the respective Food and Environmental HygieneDepartment Licensing Office, an officer from the Buildings Department will take part in :-
(a) the joint site inspection to check that the submitted plans conform to the actual
SeeAppendix K
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
30/138
19
premises, to determine the suitability of the premises and the scope of any
proposed or required alterations; and
(b) the Application Vetting Panel meeting to discuss the application with other
departments concerned and the applicant.
52. In all cases, the applicant will be handed a copy of the Buildings Departmentsrequirements for compliance at the Application Vetting Panel meeting. If there are serious
or major impediments to licensing, the applicant will also be informed at the meeting with
advice on any remedies.
3-tier System for Verification of Compliance with Building Safety Requirements
53. With effect from 1 August 1996, in order to streamline and simplify the processing
of verification of compliance with building safety requirements for restaurant licensing, the
Buildings Department has adopted a 3-tier system for verification of compliance with building
safety requirements, under which building requirements are graded into Categories 1, 2 and 3
as follows:
(a) Category 1
The applicant is required to certify compliance direct to the respective Food and
Environmental Hygiene Department Licensing Office in respect of requirements
relating to matters of fact e.g. exit doors opening in direction of exit, removal of
movable obstructions from exit routes and extent of licensed area.
(b) Category 2
The AP/RSE is required to certify compliance direct to the respective Food and
Environmental Hygiene Department Licensing Office in respect of requirements
involving a professional appraisal relative to well-established standards, e.g.
improvement of means of escape to stipulated standards, structural justification for
additional loading, separation between different uses and removal of unauthorized
building works.
(c) Category 3
The AP/RSE is required to verify compliance to the Buildings Department in casesinvolving more serious concerns about building safety e.g. approval of plans for
extensive alteration and addition works prior to licensing, adequacy of means of
escape from a restaurant with interface with other parts of a building and assessment
of the structural stability of a restaurant premises vis-a-vis the entire building.
A list showing the categorisation of typical building safety issues is at Appendix L. Under
this 3-tier system, the respective Food and Environmental Hygiene Department Licensing
Office will inform the applicant of the arrangements for reporting compliance with Categories
1 and 2 requirements along with the issue of the letter of requirements (paragraph 36 of Part
IV refers). However, if there are Category 3 requirements, the applicants AP/RSE is
required to report compliance with the Category 3 requirements to the Buildings Departmentthrough the Food and Environmental Hygiene Department. The respective Food and
Environmental Hygiene Department Licensing Office will not issue any letter of requirements
until after the Buildings Department has confirmed that the applicant has fully complied with
See
Appendix L
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
31/138
20
all the Category 3 requirements.
REQUESTS FOR VIEWING
APPROVED PLANS & DOCUMENTS
Requests for viewing approved plans and documents can be made in a standard
application form available in Buildings Department and prior appointment for viewing is
necessary so as to allow for the records to be retrieved. For enquiries, please contact the Plan
Retrieval Unit of Buildings Department. (Tel. No.: 2626 1207).
ENQUIRIES
For enquiries, please contact the Licensing Unit, Buildings Department, 16/F.,
Pioneer Centre, 750 Nathan Road, Kowloon (tel. No.: 2626 1257, fax no.: 2523 1872).
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
32/138
21
Part VI
THE ROLE OF THE FIRE SERVICES DEPARTMENT
The Role of the Director of Fire Services
54. The Licensing Authority will not issue any licence until after the applicant hascomplied with, among others, all requirements imposed by the Director of Fire Services.
The proof of compliance is a Fire Services Certificate and a Letter of Compliance (Ventilating
System) issued by the Fire Services Department and such certificate and letter are the pre-
requisites for the issue of a restaurant licence. Part VI describes the procedures of processing
an application for a Fire Services Certificate and Letter of Compliance (Ventilating System)
by the Fire Services Department and further enquiries in this respect can be made by
telephone or in writing to any of the Fire Protection Regional Offices and the Ventilation
Division of the Fire Services Department listed at Appendix M.
How to Obtain a Fire Services Certificate
55. The applicant does not need to apply directly to the Fire Services Department for a
Fire Services Certificate in respect of premises under application for a restaurant licence.
The Fire Services Department will, upon receiving the referral of the application for a
restaurant licence from the respective Licensing Office of the Food and Environmental
Hygiene Department, process it as an application for a Fire Services Certificate. The Fire
Services Department will directly communicate with the applicant with copies of the
correspondence to keep the Food and Environmental Hygiene Department Licensing Office
informed.
The Procedures
56. There are fire safety standard requirements published by the Fire Services
Department for the reference of applicants for restaurant licences. These requirements are
set out in Forms PPA/101(A), PPA/101(D), PPA/101(F), PPA/101(G), PPA/101(H),
PPA/101(I), PPA/101(J), PPA/101(L) and PPA/104A together with PPA/102 and PPA/117 in
respect of the requirements on fuel prepared by the Fire Services Department, which also
provide basic information about the planning of fire safety of a restaurant. The ventilating
system fire safety requirements are published in Part XI of F.S.D. Circular Letter No. 4/96.
Through the arrangements by the respective Food and Environmental Hygiene Department
Licensing Office, officers from one of the Fire Protection Regional Offices and VentilationDivision will take part in the Joint Site Inspection and the Application Vetting Panel meeting
to confirm the suitability of the premises as a restaurant. If the premises is considered
suitable for the purpose of restaurant business, the ventilating system fire safety requirements
would be issued together with the Letter of Requirements by the respective Licensing Office
of Food and Environmental Hygiene Department. Officer from the Fire Protection Regional
Office will vet the layout plan submitted by the applicant which should be drawn to scale or
with dimensions and with the following details: -
(a) The location of each and every stove;
(b) The layout of the kitchen (for general restaurant application) with fireseparation;
(c) The layout of the front food room/soda fountain;
See
Appendix M
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
33/138
22
(d) The layout of the seating accommodation;
(e) The location of kerosene tank or diesel tank, if any;
(f) The layout of every partition in the seating accommodation, whether
fixed or floating;
(g) The location of all designed windows and the portions of the designed
windows which would be sealed up by decoration;
(h) Any stage or dance hall in the seating accommodation;
(i) Any Karaoke cubicles;
(j) The location of all existing Fire Service Installations in the existing
premises;
(k) The type of fuel to be used.
The applicant will be informed of the inspection result by the respective Fire Protection
Regional Office in the following manner as appropriate :-
(a) Where the premises are found unsuitable, a letter of objection will be
issued together with the reasons; or
(b) Where the premises are found suitable, a letter enclosing the relevant FireServices requirements for compliance will be issued.
Fire Services Requirements
57. Fire Services requirements are measures to protect the safety of public and the
premises against fire, limit its spread and at the same time give warning to the occupants of
the premises. Applicants will be required to obtain the following certificates or licence/letter
of approval :-
(a) a Certificate of Fire Service Installations and Equipment (FS 251) and a
Certificate of Compliance (FSI/314A) issued by a registered fire serviceinstallation contractor;
(b) a Dangerous Goods Licence or Letter of Approval in respect of the
storage and use of dangerous goods issued by the Fire Services
Department;
(c) a Letter of Compliance (Ventilating System) issued by the Fire Protection
(Fire Safety) Command (Ventilation Division); and
(d) a test report or a Catalogue of Emergency Lighting Unit.
Samples of the Certificate of Fire Service Installations and Equipment (FS 251) and
Certificate of Compliance (FSI/314A), Dangerous Goods Licence as well as Letter of
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
34/138
23
Compliance (Ventilating System) are at Appendix N for reference and the following
paragraphs describe in detail the purpose of each of these certificates and licence/letter of
approval.
Certificate of Fire Service Installations and Equipment (FS 251) and Certificate of
Compliance (FSI/314A)
58. These certificates are issued by a registered fire service installation contractor.
The purpose of these certificates is to ensure that the fire service installations provided to
protect the building are still in efficient working order after decoration of the premises.
59. The applicant should appoint a registered fire service installation contractor to
inspect and certify the installation and to repair any defects that may have been caused by
alterations and additions to the premises. Upon completion of the work, a copy of the
Certificate should be submitted to the Director of Fire Services. The details of all registered
fire service installation contractors are available for inspection at the Fire Protection Regional
Offices* and all fire stations.
Dangerous Goods Licence/Letter of Approval
60. The Dangerous Goods Licence/Letter of Approval is issued by the Fire Services
Department. The purpose of this licence/letter of approval is to ensure that dangerous goods
stored or used in the premises do not constitute risks to the restaurant. The type of
licence/letter of approval required by the Fire Services Department depends on the fuel to be
used which in turn may restrict :-
(a) the location of the food premises;
(b) the quantity of fuel that may be permitted; and(c) the design of the kitchen.
Paragraphs 61 and 62 hereunder list the restrictions to be imposed on the use of liquid fuel
and solid fuel respectively and paragraphs 76 to 81 in Part VII list the restrictions to be
imposed on the use of electricity, town gas and liquefied petroleum gas as fuel.
Liquid Fuel
61. Liquid fuel is not recommended to be used in food business because it can easily
cause dark smoke emission. From the fire safety point of view, only two types of liquid fuel
are permitted. These are :-
(a) Diesel, which may be stored subject to approval/licensing as follows :-
(i) for quantity not exceeding 2,500 litres in service tanks, it should be
approved by the Director of Fire Services under regulation 99A(1)
of the Dangerous Goods (General) Regulations; and
(ii) for quantity exceeding 2,500 litres in underground tanks, it requires
a Dangerous Goods Licence issued by the Fire Services Department
under the Dangerous Goods Ordinance.
The applicant is also advised to read paragraph 18 in Part II for the requirements of
the Food and Environmental Hygiene Department.
* The addresses and telephone numbers of these offices are at Appendix M.
ee
Appendix N
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
35/138
24
(b) Kerosene, the capacity of the storage/use of which shall not exceed 20
litres and a separate licensable dangerous goods store shall be provided
for any additional storage/use in excess of the quantity under Section 6 of
the Dangerous Goods Ordinance, Cap. 295.
Solid Fuel
62. Fire separation between the kitchen and other parts of the premises is required.
The applicant is also advised to read paragraph 17 in Part II for the requirements of the Food
and Environmental Hygiene Department.
Letter of Compliance (Ventilating System)
63. The Letter of Compliance (Ventilating System) is issued by the Fire Protection (Fire
Safety) Command (Ventilation Division) of the Fire Services Department. The purpose of
this letter is to ensure that the ventilating system installed in a restaurant has been inspected
and that it has complied with the Ventilation of Scheduled Premises Regulation and fire safety
requirements on the mechanical ventilating system issued by the Fire Services Department.
64. The applicant is required to have their ventilation/air-conditioning layout plans
approved by appropriate Food and Environmental Hygiene Department Licensing Office, then
he should report completion to Ventilation Division of Fire Services Department. The Fire
Services Department will process the application when it receives the approved ventilation
layout plans from the respective Food and Environmental Hygiene Department Licensing
Office. Upon receiving the report of completion on ventilating system from the applicant, an
officer of the Fire Protection (Fire Safety) Command (Ventilation Division) will inspect the
premises. He will issue a Letter of Compliance (Ventilating System) direct to the applicant
and copy to the respective Licensing Office of Food and Environmental Hygiene Departmentif he is satisfied that the ventilating system complies with the Ventilation of Scheduled
Premises Regulation.
65. For ventilating system found not complying with fire safety requirements, the Fire
Protection (Fire Safety) Command (Ventilation Division) will advise the applicant or his
appointed representative in writing of any remedial works required at the time of inspection.
A formal list of non-compliance works would be formulated and issued to the applicant
through the respective Licensing Office of Food and Environmental Hygiene Department.
The applicant is required to report of compliance to the Fire Protection (Fire Safety)
Command (Ventilation Division) after the remedial work has been completed. Failure tofollow this advice will delay the issue of the Letter of Compliance (Ventilating System),
which is one of the pre-requisites for the granting of a restaurant licence.
Catalogue of Emergency Lighting Unit
66 The purpose of this catalogue is to enable the Fire Services Department to check
whether the emergency lighting unit installed meets the specified standard.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
36/138
25
Report of Compliance
67. Unless specifically requested, in order to give the applicant sufficient time to
decorate the premises and to comply with the requirements, no follow-up inspection will be
made by the Fire Services Department within three months after the issue of letter of fire
services requirements for compliance (paragraph 56). The respective Licensing Office ofFood and Environmental Hygiene Department would be informed if no report of compliance
for ventilating system is received within three months after each inspection.
Follow-up Inspection
68. To avoid delay, the applicant or his authorized representative should, upon
completion of all works required, inform the respective Fire Protection Regional Office*
either by phone or in writing, or the Ventilation Division of the Fire Services Department* in
writing, so that a follow-up inspection can be arranged.
Issue of a Fire Services Certificate
69. Upon confirmation during the follow-up inspection that all FS requirements have
been complied with and layout is in conformity with the approved plan, the applicant will be
advised in writing by the Fire Services Department (and the letter will be copied to the
respective Food and Environmental Hygiene Department Licensing Office) that a Fire
Services Certificate is available for collection upon payment of the prescribed fee.
70. A Fire Services Certificate is a pre-requisite for the issue of any restaurant licence
and it remains valid only when its actual layout conforms with the latest plans accepted by
Fire Services Department with all necessary fire safety requirements stipulated being in fullcompliance. If there are alterations or additions to the premises which may affect fire safety,
a new Fire Services Certificate will be required.
Re-visit for Non-compliance
71. At the initial follow-up inspection, if there are outstanding FS requirements, the
respective Fire Protection Regional Office will advise the applicant in writing of any remedial
works required and carry out further follow-up inspections upon notified the completion of the
requirements by the applicant until the application is aborted, or a Fire Services Certificate has
been issued. If the food premises are found operated without a valid licence, the Food andEnvironmental Hygiene Department will be informed to take appropriate action.
72. Upon confirmation during the subsequent inspections that all FS requirements have
been complied with and layout is in conformity with the approved plan, a Fire Services
Certificate will be issued.
___________________________________________________________________________
* The addresses and telephone numbers of these offices are at Appendix M.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
37/138
26
Part VII
THE ROLE OF THE ELECTRICAL AND
MECHANICAL SERVICES DEPARTMENT
The Role of the Director of Electrical and Mechanical Services
73. The applicant shall submit relevant certificates to the licensing authority if
electricity, town gas and liquefied petroleum gas (LPG) is to be used in a restaurant.
74. These certificates shall be issued by electrical or gas contractors registered with the
Electrical and Mechanical Services Department, to certify that the electrical or gas installation
in the restaurant complies with legislative requirements and codes of practice.
75. Paragraphs 76 to 81 hereunder list the requirements for each type of fuel. Any
specific queries concerning the use of electricity, town gas or LPG can be directed to the
Electrical and Mechanical Services Department*.
Electricity
76. No restriction is imposed on the use of electricity gas fuel for a food business.
However, all fixed electrical installation works should be carried out by a registered electrical
contractor/worker. Either a copy or the original of the Work Completion Certificate (Form
WR1) issued both as regards the fixed electrical installation and for the purposes of regulation
19 of the Electricity (Wiring) Regulations, (Cap. 406 sub.leg.) for a new fixed electrical
installation, or a copy of endorsed Periodic Test Certificate (Form WR2) issued both as
regards the fixed electrical installation and for the purposes of regulation 20 of those
regulations, should be obtained and forwarded to the Licensing Authority.
Town Gas and LPG
77. All gas installation works on the premises must be carried out in accordance with
the Gas Safety Ordinance (Cap. 51) by a registered gas contractor. Such works include new
installations, and modifications or servicing/repair of existing gas installations. The office of
the Gas Authority, the Gas Standards Office of EMSD, is responsible for enforcing gas safety
legislation and approving codes of practice for such works.
78. Town gas installations should comply with the Gas Safety Ordinance and the codesof practice issued by the Hong Kong and China Gas Company Ltd.
79. LPG installations, including portable gas appliances, should comply with the Gas
Safety Ordinance and the Gas Utilisation Code of Practice 06 (GU 06) LPG Installations
for Catering Purposes in Commercial Premises issued by the Gas Authority. In particular,
the following should be noted :-
(a) The use or storage of LPG cylinders exceeding 130 litres nominal water
capacity requires the written approval of the Gas Authority in accordance
with the Gas Safety (Gas Supply) Regulations.
___________________________________________________________________________
* The address and telephone number of this Department is at Appendix O.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
38/138
27
(b) LPG shall not be supplied to areas below ground level.
(c) LPG cylinders (other than for LPG dim-sum trolleys) should not be used
unless a central LPG, or Towngas, piped supply is unavailable in the
premises. Cylinders must be placed in a purpose-built storage chamber
and connected to appliances by means of rigid metal pipework.
80. The following describes the procedures that an applicant for a restaurant licence has
to follow under the Work Certification Scheme, when proposing gas installation and
modification works on the premises under application :-
(a) The applicant should select a registered gas contractor*.
(b) Prior to commencement of works, the applicant should obtain a
Certificate of Compliance signed by the registered gas contractor and
forward it to the licensing authority.
(c) Upon completion of all gas installation and modification works, to
include commissioning of gas appliances, the applicant should obtain a
signed Certificate of Completion from the registered gas contractor and
forward it to the licensing authority.
81. The Licensing Authority will check that the gas contractor has been registered for
this type of work by the Gas Standards Office and that the work certificates have been
properly completed. There will be no inspections of work for the purpose of issuing a
licence. The registered gas contractor will be responsible for ensuring that all works are
completed in accordance with legislative requirements and relevant codes of practice. TheGas Standards Office will subsequently carry out quality control of completed works from
time to time.
Lists of the contractors are available at the Food and Environmental Hygiene Department
Licensing Offices the addresses and telephone numbers of which are at Appendix A. Contractor
lists are also available at the EMSD website, http://www.info.gov.hk/emsd/index.htm.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
39/138
28
Part VIII
PROVISIONAL RESTAURANT LICENCES
Provisional General/Light Refreshment Restaurant Licences
82. Under regulation 33C of the Food Business Regulation, the Licensing Authoritymay, if such applications are made, issue Provisional General/Light Refreshment Restaurant
Licences to premises which have met all essential health, ventilation, building and fire
services requirements for the issue of provisional licences imposed by all the departments
concerned. This enables applicants to operate their restaurants on a provisional basis
following certification of compliance of essential requirements, pending the issue of full
licences.
Application and Licensing Procedures
83. Application for a provisional licence is entirely optional. If one opts for a
provisional licence, he should submit the application at the same time as he applies for a full
licence*. Application for a provisional licence without applying for a full licence will not be
considered by the Licensing Authority.
84. The licensing procedures of application for provisional licences are same as those of
application for full licences except that after the issue of the letter of requirements
(provisional licence), the applicant is required to report compliance by submission of
certifications by professionals. The flow chart at Appendix G depicts the licensing
procedures of application for provisional licences (as well as those of application for full
licences).
Criteria for Issue
85. The Licensing Authority will issue a provisional licence if :-
(a) there is no objection in principle to the application for a full licence, i.e.,
the application has been accepted by the Application Vetting Panel;
(b) the applicant has been issued with a list of essential health and ventilation
requirements (as per Appendix P) as well as building and fire services
requirements for the issue of a provisional licence; and
(c) the licensing authority is satisfied, upon receipt of the report of
compliance with the provisional licensing requirements from the
applicant enclosing certifications by professionals in prescribed forms+
that all essential requirements have been met.
86. The following professional persons are recognised by the Licensing Authority for
the purpose of certification for the issue of provisional licences :-
* Both application forms being the same and a sample is at Appendix C.
Sample of the report form is at Appendix Q.+
Sample of the prescribed forms is at Appendices R to U.
See
Appendix P
See
Appendix G
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
40/138
29
(a) authorized persons or registered structural engineers registered under the
Buildings Ordinance in respect of health and building safety
requirements;
(b) fire service installation contractors registered under the Fire Services
Ordinance in respect of fire service installations and equipment; and
(c) registered specialist contractors (ventilation works category) under the
Buildings Ordinance in respect of ventilating systems.
A list of the authorized persons and registered structural engineers, fire service installation
contractors and registered specialist contractors (ventilation works category) is kept at the
Food and Environmental Hygiene Department Licensing Offices* for reference.
Validity
87. A provisional licence shall be valid for six months to enable the licensee to operate
his restaurant on a provisional basis following certification of compliance of essential
requirements, pending the issue of a full licence.
Renewal
88. The licensing authority may in exceptional circumstances renew, before it expires, a
provisional licence for only a further period not exceeding six months, if it is satisfied that the
non-compliance with the outstanding requirements for the issue of a full licence is due to
factors beyond the reasonable control of the licensee, his contractors and his agents.
Examples of such circumstances are :-
(a) the processing of the full licence application being hindered by a cause
which is not attributable to the act, default or omission of the licensee, his
contractors and his agents; and
(b) the occurrence of such events as labour strikes, curfews and natural
disasters.
89. Applicants who intend to apply for renewal of a provisional licence should submit
an application three weeks before the expiry of the licence with evidence to show that the
failure to comply with the full licence requirements is due to factors referred to in paragraph88 above.
Transfer
90. A provisional licence is not transferable except with the consent of the licensing
authority. The existing policies and guidelines governing the transfer of full licences will
apply to application for the transfer of provisional licences.
* The addresses and telephone numbers of these offices are at Appendix A.
-
8/3/2019 A Guide to Restaurant for Hong Kong Enterprises
41/138
30
Licence Fee
91. The licence fee for the issue and renewal of a provisional licence shall be 50% of
the fee for a full licence. Nevertheless, if a full licence is issued during the validity period of
a provisional licence, refund of part of the fee paid in respect of the provisional licence will be
made on a pro-rata basis.
Monitoring
92. Premises issued with a provisional l