a l - diamond precastdiamondprecast.com/products/42-l.pdf178 a l __ _ 01295 t a 4208dl-36co lifting...

6

Upload: dinhlien

Post on 11-Mar-2018

231 views

Category:

Documents


2 download

TRANSCRIPT

178

A

L __ _ 01295

t

A

4208DL-36CO

Lifting Cable

Lifting Detail Lifting Lug

6

PLAN VIEW SCALE 1:30

� -- - --1295� -- - - -�

SECTION A-A SCALE 1:30

1

r100

Gasket (by others)--�, External Mastic Wrap

(Recommended, by others)

64

TONGUE & GROOVE DETAIL SCALE 1: 15

Mastic (by others

SUGGESTED JOINT DETAIL SCALE 1: 15

Specification and General Notes:

1. Manhole design/manufacture to ASTM C478M Specification. 2. Concrete testing to current version of ASTM C497/CSA 23.1&2. 3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Concrete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15

Description:

DI �MOND 1067 ID DONUT LID-914 OPENING

__ :¥,RECAST CONCRETE42 Donut Lid 786#-36" OPENING

Project:

7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181 Fax : 604-415-5185

www.diamondprecast.com

REINFORCEMENT PLAN VIEW SCALE 1:30

Drawn : Date :

D.L 24/09/2016

Aproved : Load Rating:

v.w. H20 RATED

Rev. No. Scale : A As Shown

01245

catalog No.

4208DL

-36CO

Dwg. No.

42-14

This drawing is the proper.ty of the Sheet No. i amond Precast Concrete. All inform ation contained herein is confidential and may 1 OF 1 no

�������:����� g;ert;,��

ut

REV.C

01295

A

PLAN VIEW SCALE 1:30

6 1 REV.C

100

2 4

1295

SECTION A-A SCALE 1:30

A

REV.C

t

Lifting Detail

25

4208DL

Lifting Lu

REV.C

Lifting Cable

�1195

Gasket (by others)--�,

External Mastic Wrap (Recommended, by others)

64

TONGUE & GROOVE DETAIL SCALE 1: 15

Mastic (by others

SUGGESTED JOINT DETAIL

SCALE 1: 15

Specification and General Notes: REV.B

1. Manhole desi n manufacture to ASTM C478M S ification. . ncrete testing to current version o . .

3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Conaete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15

DI �MOND __ :¥,RECAST CONCRETE

Desaiption:

1067 ID DONUT LID

42 Donut Lid 786#

Project:

7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181

www.diamondprecast.com

Fax : 604-415-5185

REINFORCEMENT PLAN VIEW SCALE 1:30

Drawn : Date :

D.L 07/03/2016

Aproved : Load Rating:

v.w. H20 RATED

Rev. No. Scale : C As Shown

catalog No.

4208DL

Dwg. No.

42-08

This drawing is the proper.ty of the Sheet No. i amond Precast Concrete. All inform ation contained herein is confidential and may 1 OF 1 no

�������:����� g;ert;,��

ut

A

5

---

I ---------

/ "" / "'

;(9 2

/ I

I

I

\

\

PLAN I VIEW SCALE 1:30

SECTION A-ASCALE 1:30

01295 OD

REV.C 3

1001 2

Gasket (by others)--�, External Mastic

(Recommended,

64

TONGUE & GROOVE DETAILSCALE 1: 15

Mastic (by others

SUGGESTED JOINT DETAILSCALE 1: 15

Specification and General Notes: REV.B

1. Manhole desi n manufacture to ASTM C478M S ification. . ncrete testing to current version o . .

3. Min. concrete compressive strength 30 MPa with Max. W/C ratio of 0.5 4. Gasket to ASTM C-443 specification (by others). 5. Concrete cover to be Min.25mm. 6. All dimensions to be millimeter. 7. Welded wire mesh overlap to be 300mm. 8. Manhole design and construction to MMCD manhole specification section 02725. 9. Manufacturing tolerance to be+/- 5mm. 10. Conaete Exposesure Class to be A-3 11. Min. Stripping Strength to be 15MPa 12. All Form Finish to be Standard Grade 13. All Unformed Finish to be Steel Trowelled Finish or Wood Float Finish 14. Lifting cable and accessaries to meet the strength requirement in lifting detail 15. Hoisting and Rigging system to meet WORK SAFE BC OHS Regulation Guideline Part 14/15

DI �MOND __ :¥,RECAST CONCRETE

Description:

1067 ID Donut Lid Hatch Opening

42 Donut Lid Hatch Opening 600 #

Project:

t 4208DLH

Lifting cable

Lifting Lug

Lifting Detail

REV.C

912 X 608 OPENING

BOTTOM REINFORCEMENT PLAN VIEWSCALE 1:30

Drawn: Date: catalog No.

D.L 31/03/2016 4208DLH

Aproved: Load Rating:

v.w. H20 RATED Dwg. No.

Rev. No. Scale: 42-09C As Shown

7520 Conrad Street Burnaby, B.C. V5A 2H7 Phone : 604-415-5181 Fax : 604-415-5185 This drawing is the proper.ty of the Sheet No.

iamond Precast Concrete. All information

www.diamondprecast.com contained herein is confidential and may 1 OF 1 no�������:����� g;ert;,��

ut