S.No. Particulars Estimated Cost as per DSR / SOR (Rs.) Quoted % above / below DSR-2013 (in figure and words) Quoted Amount (Rs.) B/F 1 Civil Works (Based on CPWD DSR-2013) 33,11,13,033.85 2 Civil & Fire Fighting Works (Based on Market Rates) ----- ----- 3 Electrical work : Internal and External (Based on CPWD SOR-‘2013) 66,62,354.12 4 Electrical work : Internal and External (Based on Market Rates) ----- ----- Signature of contarctor with firms seal ABSTRACT OF COST Name of Work : Construction of Bus Terminal at Maltipatpur, Puri (Odisha) Tender No. : RITES/ROC-II/CP/Maltipatpur Bus Terminal/8998-53/Tender/14 Percentage and amount to be quoted by the tenderer Total Amount Un-conditional Rebate if any Total amount after Rebate (in Figures) Total amount after Rebate (in Words)

Upload: ngoxuyen

Post on 27-May-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

S.No. Particulars Estimated Cost as per DSR / SOR (Rs.)

Quoted % above / below DSR-2013 (in

figure and words)

Quoted Amount (Rs.) B/F

1 Civil Works (Based on CPWD DSR-2013) 33,11,13,033.85

2 Civil & Fire Fighting Works (Based on Market Rates)

----- -----

3 Electrical work : Internaland External (Based onCPWD SOR-‘2013)

66,62,354.12

4 Electrical work : Internaland External (Based onMarket Rates)

----- -----

Signature of contarctor with firms seal

ABSTRACT OF COST

Name of Work: Construction of Bus Terminal at Maltipatpur, Puri (Odisha)

Tender No. : RITES/ROC-II/CP/Maltipatpur Bus Terminal/8998-53/Tender/14

Percentage and amount to be quoted by the tenderer

Total Amount

Un-conditional Rebate if any

Total amount after Rebate (in Figures)

Total amount after Rebate (in Words)

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

1 1.1 Carriage of materialsby mechanical transportincluding loading ,unloading and stacking lead 1Km.

1.1.2 Earth cum 101.27 1122.00 113624.94

2 2.6.1+1.1.2 Earth work in excavation by mechanical means(Hydraulic excavator) / manual means over areas(exceeding 30cm in depth. 1.5 m in width as wellas 10 sqm on plan) including disposal ofexcavated earth, lead upto 50m and lift upto 1.5m,disposed earth to be levelled and neatlydressed.

2.6.1 All kinds of soil cum 247.77 29293.99 7258171.90

3 2.8 Earth work in excavation by mechanicalmeans (Hydraulic excavator) / manual meansin foundation trenches or drains (not exceeding1.5 m in width or 10 sqm on plan) includingdressing of sides and ramming of bottoms, liftupto 1.5 m, including getting out the excavatedsoil and disposal of surplus excavated soil asdirected, within a lead of 50 m.

2.8.1 All kinds of soil. cum 148.25 2799.00 414951.75

4 2.13 Excavating trenches of required width for pipes,cables, etc,including excavation for sockets, depthupto 1.5 m including getting out the excavatedmaterials, returning the soil as required in layersnot exceeding 20 cm in depth, includingconsolidating each deposited layers by ramming,watering etc. stacking serviceable material formeasurements and disposal of unserviceablematerial as directed, within a lead of 50m :

a 2.13.1.2 Pipes, cables exceeding 80 mm dia but notexceeding 300 mm dia. metre 414.75 1714.00 710881.50

b 2.13.1.3 Pipes, cables exceeding 300 mm dia but notexceeding 600mm dia. metre 477.30 17.00 8114.10

5 2.24 Extra rates for quantities of works, executed :2.24.1 In or under water and/or liquid mud, including

pumping out water as required.metre depth 29.30 22533.84 660241.51

6 4.1 Providing and laying in position cement concreteof specified grade excluding the cost of centeringand shuttering - All work up to plinthlevel :

a 4.1.3 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) cum 4921.70 20.00 98434.00

b 4.1.8 1:4:8 (1 Cement : 4 coarse sand : 8 graded stoneaggregate 40 mm nominal size) cum 3920.65 2337.75 9165499.54

c 4.1.11 1:5:10 (1 cement : 5 fine sand : 10 graded stoneaggregate 40 mm nominal size) cum 3407.25 27.00 91995.75

CONSTRUCTION BUS TERMINAL AT MALTPATPUR (PURI) ODISHA

Civil and Fire Fighting Works

1 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

7 4.2 Providing and laying cement concrete in retainingwalls, return walls, walls (any thickness) includingattached pilasters, columns, piers, abutments,pillars, posts, struts, buttresses, string or lacingcourses, parapets, coping, bed blocks, anchorblocks, plain window sills, fillets, sunken floor,etc.,up to floor five level, excluding the cost ofcentering, shuttering and finishing :

4.2.3 1:2:4 (1 Cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size) cum 5822.15 35.58 207152.10

8 4.20 Providing and laying in position ready mixed plaincement concrete, with cement content as perapproved design mix and manufactured in fullyautomatic batching plant and transported to site ofwork in transit mixer for all leads, havingcontinuous agitated mixer, manufactured as permix design of specified grade for plain cementconcrete work, including pumping of R.M.C. fromtransit mixer to site of laying and curing, excludingthe cost of centering, shuttering and finishing,including cost of curing, admixtures inrecommended proportions as per IS : 9103 toaccelerate/ retard setting of concrete, improveworkability without impairing strength anddurability as per direction of the Engineer - in -charge.

4.20.1 All works upto plinth level :4.20.1.1 M-15 grade plain cement concrete (cement

content considered @ 240 kg/cum) cum 5505.00 53.23 293031.15

9 4.20.1.2 M-10 grade plain cement concrete (cementcontent considered @ 220 kg/cum) cum 5376.65 9586.24 51541857.30

10 5.9 Centering and shuttering including strutting,propping etc. and removal of form for :

a 5.9.1 Foundations, footings, base of columns etc formass concrete.

sqm186.40 4500.00 838800.00

b 5.9.3 Suspended floors, roofs, landings, balconiesand access platform.

sqm371.80 83.00 30859.40

c 5.9.4 Shelves (Cast in situ) sqm 371.80 123.32 45850.38d 5.9.5 Lintels, beams, plinth beams, girders, bressumers

and cantilevers sqm 309.80 4458.99 1381395.10e 5.9.6 Columns, Pillars, Piers, Abutments, Posts and

Strutssqm

423.00 6939.68 2935484.64

11 5.22 Steel reinforcement for R.C.C. work includingstraightening, cutting, bending, placing in positionand binding all complete upto plinth level.

5.22.6 Thermo-Mechanically Treated bars kg. 66.50 708201.21 47095380.47

12 5.22A Steel reinforcement for R.C.C. work includingstraightening, cutting, bending, placing in positionand binding all complete above plinth level.

5.22A.6 Thermo-Mechanically Treated bars kg 66.50 4977.58 331009.07

2 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

13 5.30 Reinforced cement concrete work in beams,suspended floors, roofs having slope up to 15°landings, balconies, shelves, chajjas, lintels,bands, plain window sills, staircases and spiralstair cases up to floor five level excluding the costof centering, shuttering, finishing andreinforcement with 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominalsize). cum 6107.15 36.00 219857.40

14 5.37 + 5.34 Providing and laying in position ready mixed M-30grade concrete for reinforced cement concretework, using cement content as per approveddesign mix, manufactured in fully automaticbatching plant and transported to site of work intransit mixer for all leads, having continuousagitated mixer, manufactured as per mix design ofspecified grade for reinforced cement concretework, including pumping of R.M.C. from transitmixer to site of laying , excluding the cost ofcentering, shuttering finishing and reinforcement,including cost of admixtures in recommendedproportions as per IS : 9103 to accelerate/ retardsetting of concrete, improve workability withoutimpairing strength and durability as per directionof the Engineer - in - charge.

(Note :- Cement content considered in this item is@ 340 kg/cum. Excess/less cement used as perdesign mix is payable/recoverable separately).

All works upto plinth level cum 6117.05 205.56 1257420.80

15 5.37 Providing and laying in position ready mixed M-25grade concrete for reinforced cement concretework, using cement content as per approveddesign mix, manufactured in fully automaticbatching plant and transported to site of work intransit mixer for all leads, having continuous agitated mixer,manufactured as per mix design of specifiedgrade for reinforced cement concrete work,including pumping of R.M.C. from transit mixer tosite of laying , excluding the cost of centering,shuttering finishing and reinforcement, includingcost of admixtures in recommended proportionsas per IS : 9103 to accelerate/ retard setting ofconcrete, improve workability without impairingstrength and durability as per direction of theEngineer - in - charge.

(Note :- Cement content considered in this item is@ 330 kg/cum. Excess/less cement used as perdesign mix is payable/recoverable separately).

a 5.37.1 All works upto plinth level cum 6052.90 5514.35 33377809.12b 5.37.2 All works above plinth level upto floor V level cum 6701.45 52.87 354305.66

3 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

16 6.1' Brick work with common burnt clay F.P.S. (nonmodular) bricks of class designation 75 infoundation and plinth in:

6.1.2 Cement mortar 1:6 (1 cement : 6 coarse sand)cum 4646.50 638.28 2965768.02

17 6.38 Providing and laying autoclaved aerated cementblocks masonry with 100 / 200 mm thick AACblocks in super structure above plinth level up tofloor V level in cement mortar 1:4 (1 cement : 4coarse sand ). The rate includes providing andplacing in position 2 Nos 6 mm dia M.S. bars atevery third course of masonry work.

cum 4827.45 482.47 2329099.80

18 8.2 Providing and fixing 18mm thick gang sawcut, mirror polished, premoulded andprepolished, machine cut for kitchen platforms,vanity counters, window sills , facias and similarlocations of required size, approved shade, colourand texture laid over 20mm thick base cementmortar 1:4 (1 cement : 4 coarse sand) jointstreated with white cement, mixed with matchingpigment, epoxy touch ups, including rubbing,curing, moulding and polishing to edges to givehigh gloss finish etc. complete at all levels.

8.2.2 Granite of any colour and shadea 8.2.2.1 Area of slab upto 0.5 sqm. sqm 3724.70 17.00 63319.90

8.2.2.2 Area of slab over 0.5sqm. sqm 3769.70 402.02 1515494.79

19 8.3 Providing edge moulding to 18 mm thick marblestone counters, Vanities etc., including machinepolishing to edge to give high gloss finish etc.complete as per design approved by Engineer-in-Charge.

8.3.2 Granite work sqm 210.65 170.00 35810.50

20 8.4 Extra for fixing marble /granite stone, over andabove corresponding basic item, in facia anddrops of width upto 150 mm with epoxy resinbased adhesive, including cleaning etc. complete.

metre 225.75 170.00 38377.50

21 8.5 Extra for providing opening of required size &shape for wash basin/ kitchen sink in kitchenplatform, vanity counter and similar location inmarble/Granite/stone work, including necessaryholes for pillar taps etc. including moulding,rubbing and polishing of cut edges etc. complete.

each 350.80 66.00 23152.80

4 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

22 8.10 Providing and fixing stone slab with tablerubbed,edges rounded and polished, of size75x50 cm deep and 18 mm thick, fixed in urinalpartitions by cutting a chase of appropriatewidth with chase cutter and embedding the stonein the chase with epoxy grout or with cementconcrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 6 mm nominal size) asper direction of Engineer-in-charge and finishedsmooth.

8.10.2 Granite Stone of approved shade. sqm 2963.40 30.00 88902.00

23 9.12 Extra for providing frosted glasspanes 4 mm thickinstead of ordinary float glass panes 4mm thick indoors,windows and clerestory windowshutters.(Area of opening for glass panesexcluding portion inside rebate shall be measured)

sqm 5.80 22.68 131.54

24 9.83 Providing and fixing aluminium extruded sectionbody Die cast body tubular type universalhydraulic door closer(having brand logo withISI,IS: 3564, embossed on the body,door weightupto 36Kg to 80 kg. and door width upto 700mmto 1000mmwith necessary ascessories andscrews etc complete.

each 737.35 80.00 58988.00

25 9.84 Providing and fixing aluminium Die cast bodytubular type universal hydraulic doorcloser(heaving brand logo with ISI,IS: 3564,embossed on the body,door weight up to 36Kg to80 Kg. And door width upto 701mm to1000mmwith necessary ascessories and Screws etccomplete. each 1027.20 71.00 72931.20

26 9.97 Providing and fixing aluminium tower bolts,ISImarked, anodised(anodic coating not less thanAC 10 as per IS:1868) transparent or dyed torequired colour or shade , with necessary screwsetc. complete.

a 9.97.3 200x10mm each 76.40 382.00 29184.80b 9.97.4 150x10mm each 62.75 160.00 10040.00

27 9.100 Providing and fixing aluminium handles,ISImarked, anodised(anodic coating not less thangrade AC 10 as per IS:1868) transparent or dyedto required colour or shade , with necessaryscrews etc. complete.

9.100.1 125mm each 66.95 160.00 10712.00

28 9.101 Providing and fixing aluminium hanging floor doorstoppers,ISI marked, anodised(anodic coating notless than AC 10 as per IS:1868) transparent ordyed to required colour or shade , with necessaryscrews etc. complete.

9.101.2 Twin rubber stoppers each 80.20 151.00 12110.20

5 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

29 9.102 Providing and fixing aluminium casement stays,ISImarked, anodised (anodic coating not less thangrade AC 10 as per IS:1868) transparent or dyedto required colour and shade , with necessaryscrews etc. complete. each 68.40 80.00 5472.00

30 9.109 Providing and fixing PTMT door catcher of length72mm and dia of 42mm with sutiable washersweighing not less than 33 grams. each 34.10 151.00 5149.10

31 10.1 Structural steel work in single section, fixed with or without connecting plate, including cutting,hoisting, fixing in position and applying a primingcoat of approved steel primer all complete.

kg 66.85 13931.09 931293.37

32 10.2 Structural steel work riveted, bolted or welded inbuilt up sections, trusses and framed work,including cutting, hoisting, fixing in position andapplying a priming coat of approved steel primerall complete. kg 73.65 444027.00 32702588.55

33 10.26 Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing,staircase railing and similar works, includingapplying priming coat of approved steel primer.

10.26.1 M.S. tube kg 97.45 22302.00 2173329.90

34 10.28 Providing and fixing stainless steel ( Grade 304)railing made of Hollow tubes, channels, platesetc., including welding, grinding, buffing, polishingand making curvature (wherever required) andfitting the same with necessary stainless steelnuts and bolts complete, i/c fixing the railing withnecessary accessories & stainless steel dashfasteners , stainless steel bolts etc., of requiredsize, on the top of the floor or the side of waistslab with suitable arrangement as per approval ofEngineer-in-charge,( for payment purpose only weight of stainlesssteel members shall be considered excludingfixing accessories such as nuts, bolts, fastenersetc.).

kg 611.10 2226.80 1360797.48

35 11.4 52 mm thick cement concrete flooring withconcrete hardener topping, under layer 40 mmthick cement concrete 1:2:4 (1 cement : 2 coarsesand : 4 graded stone aggregate 20 mm nominalsize) and top layer 12 mm thick cement hardenerconsisting of mix 1:2 (1 cement hardener mix : 2graded stone aggregate 6 mm nominal size) byvolume, hardening compound mixed @ 2 litre per50 kg of cement or as per manufacturer’sspecifications. This includes cost of cement slurry,but excluding the cost of nosing of steps etc.complete.

sqm 480.10 421.32 202275.73

6 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

36 11.6 Cement plaster skirting up to 30 cm height, withcement mortar 1:3 (1 cement : 3 coarse sand),finished with a floating coat of neat cement.

11.6.1 18 mm thick sqm 299.20 42.13 12605.30

37 11.8 Extra for making chequers of approved pattern oncement concrete floors, steps, landing, pavementsetc. sqm 30.20 187.00 5647.40

38 11.26 Kota stone slab flooring over 20 mm (average)thick base laid over and jointed with grey cementslurry mixed with pigment to match the shade ofthe slab, including rubbing and polishing completewith base of cement mortar 1 : 4 (1 cement : 4coarse sand) :

11.26.1 25 mm thick sqm 1071.70 189.37 202947.83

39 11.36 Providing and fixing Ist quality ceramic glazed walltiles conforming to IS: 15622 (thickness to bespecified by the manufacturer), of approved make, in all colours, shades except burgundy, bottlegreen, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1cement : 3 coarse sand) and jointing with greycement slurry @ 3.3kg per sqm, including pointingin white cement mixed with pigment of matchingshade complete.

sqm 793.60 270.00 214272.00

40 11.37 Providing and laying Ceramic glazed floor tiles ofsize 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS :15622 of approved make in colours such asWhite, Ivory, Grey, Fume Red Brown, laid on 20mm thick cement mortar 1:4 (1 Cement : 4 Coarsesand), including pointing the joints with whitecement andmatching pigment etc., complete. sqm 822.10 250.00 205525.00

41 11.46 Providing and laying Vitrified tiles in different sizes(thickness to be specified by manufacturer), withwater absorption less than 0.08 % and conformingto I.S. 15622, of approved make, in all colours &shade, in skirting, riser of steps,dado, over 12 mmthick bed of cement mortar 1:3 (1 cement: 3coarse sand), including grouting the joint withwhite cement & matching pigments etc. complete.

11.46.1 Size of Tile 500x500 mm sqm 1250.75 4430.82 5541848.12

7 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

42 11.47 Providing and laying Vitrified tiles in different sizes(thickness to be specified by the manufacturer),with water absorption less than 0.08% andconforming to IS: 15622, of approved brand &manufacturer, in allcolours and shade, in skirting, riser of steps, laidwith cement based high polymer modified quickset tile adhesive (water based) conforming to IS:15477, in average 6 mm thickness, includinggrouting of joints (Payment for grouting of joints tobe made separately).

11.47.2 Size of Tile 600x600 mm sqm 1597.20 770.77 1231073.84

43 11.49 Providing and laying Vitrified tiles in floor withdifferent sizes (thickness to be specified by themanufacturer), with water absorption less than0.08% and conforming to IS:15622 , of approvedbrand & manufacturer, in all colours and shade,laid with cement based high polymer modifiedquick set tile adhesive (water based) conformingto IS : 15477, in average 6 mm thickness,including grouting of joints (Payment for groutingof joints to be made separately).

11.49.2 Size of Tile 600x600 mm sqm 1539.85 7647.71 11776326.24

44 11.5 Add for Grouting the Joints with white cement andmatching pigmant in the items of fixing of vetrifiedtiles. Sqm 8.15 7647.71 62328.84

45 12.45 Providing and fixing false ceiling at all heightincluding providing and fixing of frame work madeof special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120gms/sqm (both side inclusive) as per IS : 277 andconsisting of angle cleats of size 25 mm wide x1.6 mm thick with flanges of 27 mm and 37mm, at1200 mm centre to centre, one flange fixed to theceiling with dash fastener 12.5 mm dia x 50mmlong with 6mm dia bolts, other flange of cleat fixedto the angle hangers of 25x10x0.50 mm ofrequired length with nuts & bolts of required sizeand other end of anglehanger fixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mmcentre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80 mm with taperedflangesof 26 mm each having lips of 10.5 mm, at 450 mmcentre to centre, shall be fixed in a directionperpendicular to G.I. intermediate channelwith connecting clips made out of 2.64 mm dia x230 mm long G.I. wire at every junction, includingfixing perimeter channels 0.5 mm

8 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

thick 27 mm high having flanges of 20 mm and 30mm long, the perimeter of ceiling fixed toall/partition with the help of rawl plugs at 450 mmcentre, with 25mm long dry wall screws @ 230mm interval, including fixing of gypsum board toceiling section and perimeter channel with thehelp of dry wall screws of size 3.5 x 25 mm at 230mm c/c, including jointing and finishing to a flushfinish of tapered and square edges of the boardwith recommended jointing compound , jointingtapes , finishing with jointing compound in 3 layerscovering upto 150 mm on both sides of joint andtwo coats of primer suitable for board, all as permanufacturer's specification and also including thecost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeterchannels suitably fixed, all complete as perdrawings, specification and direction of theEngineer in Charge but excluding the cost ofpainting with :

12.45.3 12.5mm thick tapered edge gypsum moistureresistant board. sqm 891.40 109.49 97599.39

46 12.52 Providing and fixing tiled false ceiling of approvedmaterials of size 595x595 mm in true horizontallevel, suspended on inter locking metal grid of hotdipped galvanized steel sections ( galvanized @120 grams/ sqm, both side inclusive) consisting ofmain "T" runner with suitably spaced joints to getrequired length and of size 24x38 mm made from0.30 mm thick (minimum) sheet, spaced at 1200mm center to center and cross "T" of size 24x25mm made of 0.30 mm thick (minimum) sheet,1200 mm long spaced between main "T" at 600mm center tocenter to form a grid of 1200x600 mm and

9 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

secondary cross "T" of length 600 mm and size24x25 mm made of 0.30 mm thick (minimum)sheet spaced at 1200mm C/Cto be interlocked atmiddle of the 1200x600 mm panel to form grids of600x600 mm and wall angle of size 24x24x0.3mm and laying false ceiling tiles of approvedtexture in the grid including, requiredcutting/making, opening for services like diffusers,grills, light fittings, fixtures, smoke detectors etc.Main "T" runners to be suspended from ceilingusing GI slotted cleats of size 27 x 37 x 25 x1.6mm fixed to ceiling with 12.5 mm dia and 50 mmlong dash fasteners, 4 mm GI adjustable rods withgalvanised butterfly level clips of size 85 x 30 x0.8 mm spaced at 1200 mm center to centeralong main T, bottom exposed width of 24 mm ofall T-sections shall be pre-painted with polyesterpaint, all complete for all heights as perspecifications, drawings and as directed byEngineer-in-charge.

12.52.3 12.5 mm thick square edge PVC laminatedGypsum tile of size 595x595 mm, made ofgypsum plaster board manufactured from naturalgypsum as per IS 2095 part 1 and laminated withwhite 0.16 mm thick fire retardant PVC film on the face side and 12 micron metalized polyster on theback side with all edges sealed with the face sidePVC film which goes around wraps the egdes andis bondede to the edges and the back sidemetalized polysterr film so as to make the tilecompletely sealed unit.

sqm 1103.00 9821.39 10832993.17

47 12.52.4 12.5 mm thick fully Perforated Gypsum Board tilemade from plasterboard having glass fibreconforming to IS: 2095 part I , of size 595x595mm, having perforation of 9.7x9.7 mm at 19.4 mmc/c with center borders of 48 mm and the sideborders of 30 mm, backed with non woven tissueon the back side, having an NRC ( NoiseReduction Coefficient) of 0.79, with 50 mm resinbonded glass wool backing. sqm 1122.50 1546.86 1736350.35

48 13.1 12 mm cement plaster of mix :13.1.2 1:6 (1 cement: 6 fine sand) sqm 133.85 6956.75 931160.99

49 13.3 20 mm cement plaster of mix :13.3.2 1:4(1 cement: 4 fine sand) sqm 184.70 4080.00 753576.00

50 13.7 12mm Cement plaster finished with a floating coatof neat cement of mix:

13.7.2 Cement:4 Fine sand.) sqm 180.60 415.00 74949.00

51 13.9 Cement plaster 1:3 (1 cement: 3 coarse sand)finished with a floating coat of neat cement.

13.9.1 12 mm cement plaster sqm 200.60 1167.75 234250.65

10 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

52 13.21 Extra for providing and mixing water proofingmaterial in cement plaster work in proportionrecommended by the manufacturers.

Per bag of 50 Kg. cement used in the mix. 46.70 318.10 14855.27

53 13.46 Finishing walls with Acrylic smooth exterior paintof required shade

13.46.1 New works 2 or more coat [email protected]/10Sqm. Over and including priming coatof exterior prymer. Applied @ 2.2kg / 10sqm

sqm 78.10 5940.50 463953.05

54 13.80 Providing and applying white cement based puttyof average thickness 1 mm, of approved brandand manufacturer, over the plastered wall surfaceto prepare the surface even and smoothcomplete. sqm 85.40 11036.75 942538.45

55 13.83 Wall painting with premium acrylic emulsion paintof interior grade, having VOC (Volatile OrganicCompound ) content less than 50 grams/ litre ofapproved brand and manufacture, includingapplying additional coats wherever required toachieve even shade and colour.

sqm 70.75 4925.00 348443.7513.83.2 Two coats

56 13.84 Painting with synthetic enamel paint, having VOC(Volatile Organic Compound) content less than150 grams/ litre, of approved brand andmanufacture, including applying additional coatswherever required to achieve even shade andcolour

13.84.2 Two coats sqm 67.00 7238.39 484972.13

57 13.85 Applying priming coats with primer of approvedbrand and manufacture, having low VOC (VolatileOrganic Compound ) content.

13.85.3 With water thinnable cement primer on wallsurface having VOC content less than 50grams/litre sqm 31.55 11036.75 348209.46

58 16.3 Supplying and stacking at site.a 16.3.3 53mm to 22.4mm size stone aggregate. Cum 1296.15 3005.06 3895008.52b 16.3.7 Stone screening11.2mm nominal size (Type B)

cum 1453.80 1283.00 1865225.40c 16.3.10 Moorum Cum 646.55 384.60 248663.13

59 16.4 Laying, spreading and compacting stoneaggregate of specified sizes to WBMspecifications in uniform thickness, hand picking,rolling with 3 wheeled road/vibratory rollar 8-10tonne capacity in stages to proper grade andcamber , applying and brooming requisite type ofscreening/ binding material to fillup interstices ofcoarse aggregate, watering and compacting torequired density. Cum 388.85 3005.06 1168517.58

11 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

60 16.63 Providing, laying and making kerb channel 30 cmwide and 50 mm thick with cement concrete 1:3:6(1 cement: 3 coarse sand:6 graded stoneaggregate 20 mm nominal size) over 75mm bedof dry brick ballast 40 mm nominal size, wellrammed and consolidated and grouted with finesand, including finishing the top smooth etc.complete and as per direction of Engineer-in-charge. sqm 318.25 243.03 77344.30

61 16.69 Providing and laying at or near ground levelfactory made kerb stone of M-25 grade cementconcrete in position to the required line, level andcurvature, jointed with cement mortar 1:3 (1cement: 3 coarsesand), including making joints with or withoutgrooves (thickness of joints except at sharp curveshall not to more than 5mm), including makingdrainage opening wherever required complete etc.as per direction of Engineer-in-charge (length offinished kerb edging shall be measured forpayment). (Precast C.C. kerb stone shall beapproved by Engineer-in-charge).

cum 5236.95 28.35 148467.53

62 16.78 Construction of granular sub-base by providingclose graded Material conforming tospecifications, mixing in a mechanical mix plant atOMC, carriage of mixed material by tippers towork site, for all leads& lifts, spreading in uniform layers of specifiedthickness with motor grader on prepared surfaceand compacting with vibratory power roller toachieve the desired density, complete as perspecifications and directions of Engineer-in-Charge.

16.78.1 With material conforming to Grade-I (size range75 mm to 0.075 mm) having CBR Value-30

cum 2018.50 9586.24 19349825.44

63 16.92 Providing and fixing 10x10x7.50 cm Granite stoneblock hand cut and chisel dressed on top, forpaving in floors, drains etc. laid over 20mm thickbase mortar 1:4 (1cement:4 coarse sand) withjoints 10mm wide filled with same mortar includingruled pointing etc. complete as per direction ofengineer-in charge.

sqm 1318.80 1425.38 1879791.14

64 17.3 Providing and fixing white vitreous china pedestaltype water closet (European type) with seat andlid, 10 litre low level white vitreous china flushingcistern & C.P. flush bend with fittings &C.I.brackets, 40mm flush bend, overflowarrangement with specials of standard make andmosquito proof coupling of approved municipaldesign complete including painting of fittings andbrackets, cutting and making good the walls andfloors wherever required :

12 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

17.3.2 W.C. pan with ISI marked black solid plastic seatand lid. each 4613.05 74.00 341365.70

65 17.5 Providing and fixing white vitreous china flat backhalf stall urinal of size 580x380x350mm with whitePVC automatic flushing cistern, withfittings,standard size C.P. brass flush pipe, spreaderswith unions and clamps (all in C.P. brass) withwaste fitting as per IS : 2556, C.I. trap fitting withoutlet grating and other couplings in C.P. brassincluding painting of fittings and cutting andmaking good the walls and floors whereeverrequired.

17.5.1 Single half stall urinal with 5 litre P.V.C. automaticflushing cistern. each 6249.20 38.00 237469.60

66 17.7 Providing and fixing wash basin with C.I. brackets,15 mm C.P. brass pillar taps,32 mm C.P. brasswaste of standard pattern, including painting offittings and brackets, cutting and making goodthe walls wherever require :

17.7.1 White Vitreous China Wash basin size 630x450mm with a pair of 15 mm C.P. brass pillar taps.

each 2174.65 9.00 19571.85

67 17.10 Providing and fixing Stainless Steel A ISI 304(18/8) kitchen sink as per IS 13983 with C.I.brackets and stainless steel plug 40 mmincluding painting of fittings and brackets,cutting and making good the walls whereverrequired : Kitchen sink with drain board.

17.10.1.1 510x1040 mm bowl depth 250mm. each 6975.40 4.00 27901.60

68 17.35 Providing and fixing soil, waste and vent pipes : 17.35.1 100 mm dia.

17.35.1.1 Sand cast iron S&S pipe as per IS: 1729. metre 854.85 502.00 429134.70

69 17.35.2 75 mm diametre.17.35.2.1 Sand cast iron S&S pipe as per IS: 1729. metre 705.55 414.00 292097.70

70 17.36 Providing and filling the joints with spun yarncement slurry and cement mortar 1:2 ( 1 cement :2 fine sand) in S.C.I./ C.I. Pipes :

17.36.2 100 mm dia pipe each 70.10 25.00 1752.50

71 17.37 Providing and fixing M.S. holder-bat clamps ofapproved design to Sand Cast iron/cast iron(spun) pipe embedded in and including cementconcrete blocks 10x10x10cm of 1:2:4 mix (1cement : 2 coarse sand : 4 graded stoneaggregate 20mm nominal size) including cost ofcutting holes and making good the walls etc. :

17.37.1 For 100 mm dia. Pipe each 140.65 8.00 1125.2017.37.2 For 75 mm dia. Pipe each 138.35 8.00 1106.80

13 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

72 17.38 Providing and fixing bend of required degree withaccess door, insertion rubber washer 3 mm thick,bolts and nuts complete.

17.38.1.1 100 mm dia Sand cast iron S&S as per IS - 1729each 340.30 18.00 6125.40

17.38.2.1 75 mm dia Sand cast iron S&S as per IS - 1729each 271.00 20.00 5420.00

73 17.39 Providing and fixing plain bend of requireddegree.

17.39.1.1 100 mm dia Sand cast iron S & S as per IS - 1729each 433.20 74.00 32056.80

74 17.43 Providing and fixing single equal plain junction ofrequired degree with access door, insertion rubberwasher 3 mm thick, bolts and nuts complete.

17.43.1 100x100x100 mm Sand cast iron S & S as per IS - 1729 each 484.30 34.00 16466.20

17.43.2.1 75x75x75 mm Sand cast iron S & S as per IS -1729 each 361.60 34.00 12294.40

75 17.44 Providing and fixing single equal plain junction ofrequired degree :

17.44.1 100x100x100 mm Sand cast iron S & S as per IS - 1729 each 549.35 34.00 18677.90

17.44.2.1 75x75x75 mm Sand cast iron S & S as per IS -1729 each 329.10 34.00 11189.40

76 17.57 Providing and fixing collar:17.57.1.1 100 mm Sand cast iron S & S as per IS - 1729 each 192.80 100.00 19280.0017.57.2.1 75mm Sand cast iron S & S as per IS - 1729 each 152.55 73.00 11136.15

77 17.60 Providing and fixing trap of self cleansing designwith screwed down or hinged grating with orwithout vent arm complete, including cost ofcutting and making good the walls and floors.

17.60.2.1 100 mm inlet and 75 mm outlet Sand cast iron S &S as per IS - 3989 each 976.40 136.00 132790.40

78 18.10 Providing and fixing G.I. pipes complete with G.I.fittings and clamps, including cutting and makinggood the walls etc. Internal work exposed on wall.

a 18.10.2 20 mm dia. nominal bore metre 221.50 179.00 39648.50b 18.10.3 25 mm dia. nominal bore metre 282.30 295.00 83278.50c 18.10.4 32 mm dia. nominal bore metre 333.50 66.00 22011.00

79 18.11 Providing and fixing GI pipe complete with GIfittings and clamps including making good thewalls etc.Concealed pipe including painting withanti corrosive bitumastic paint, cutting chases andmaking good the wall.

a 18.11.1 15 mm dia nominal bore metre 263.70 293.00 77264.10b 18.11.2 20 mm dia nominal bore metre 298.05 149.00 44409.45

80 18.12 Providing and fixing G.I.pipes complete with G.I.fittings including trenching and refilling etc.

14 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

a 18.12.6 50 mm dia. nominal bore metre 392.50 135.00 52987.50b 18.12.8 80 mm dia. nominal bore metre 628.35 907.00 569913.45

81 18.19 Providing and fixing gun metal non- return valve ofapproved quality (screwed end) :

a 18.19.1.1 25 mm nominal bore Horizontal each 410.00 13.00 5330.00b 18.19.6 80 mm nominal bore Vertical each 3396.80 4.00 13587.20

82 18.17 Providing and fixing gun metal gate valve with c.i.wheel of approved quality (screwed end.)

a 18.17.1 25 mm nominal bore each 427.80 29.00 12406.20b 18.17.2 32 mm nominal bore each 500.35 29.00 14510.15c 18.17.4 50.mm nominal bore each 749.40 6.00 4496.40d 18.17.6 80.mm nominal bore each 1918.85 5.00 9594.25

83 18.31 Providing and fixing C.I sluice valves (with Cap)complete with bolts, nuts, rubber insertions etc.(the tail pieces if required will be paid separately):

18.31.1.2 100mm diameter (Class II) No 3895.60 1.00 3895.60

84 18.34.1 Constructing masonry Chamber 90x90x100cminside brick work in cement mortar 1:4 (1 cement: 4 coarse sand for sluice valve , with C.I surfacebox 100mm. top diameter, 160mm bottomdiameter and 180mm deep (inside) with chainedlid and RCC top slab 1:2:4 mix (1 cement : 2coarse sand : 4 graded stone aggregate 20mmnominal size) including necessary excavationfoundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size)and inside plastering with cement mortor 1:3 (1cement : 3 coarse sand ) 12mm thick finishedwitha floating coat of neat cement complete as perstandard design:

With common burnt clay F.P.S.(non modular)bricks of class designation 7.5 Nos 11128.55 12.00 133542.60

85 18.46 Providing and fixing G.I. Union in G.I. pipeincluding cutting andthreading the pipe and making long screws etc.complete (New work)

a 18.46.1 15 mm nominal bore each 155.65 34.00 5292.10b 18.46.2 20 mm nominal bore each 178.85 60.00 10731.00c 18.46.3 25 mm nominal bore each 190.45 60.00 11427.00

86 18.48 Providing and placing on terrace (at all floorlevels) polyethylene water storage tank ISI :12701 marked with cover and suitable lockingarrangement and making necessary holes forinlet, outlet and overflow pipes but without fittingsand the base support for tank. Per litre. 6.30 25500.00 160650.00

87 18.49 Providing and fixing C.P. brass bib cock ofapproved qualityconforming to IS:8931

18.49.1 15 mm nominal bore each 458.40 74.00 33921.60

15 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

88 18.51 Providing and fixing C.P. brass long body bib cockof approved quality conforming to IS standardsand weighing not less than 690 gms.

18.51.1 15 mm nominal bore each 609.40 16.00 9750.40

89 18.53 Providing and fixing C.P. brass angle valve forbasin mixer and geyser points of approved qualityconforming to IS:8931

18.53.1 15 mm nominal bore each 506.70 238.00 120594.60

90 18.76 Cutting holes up to 30x30 cm in walls includingmaking good the same:

18.76.1 With common burnt clay F.P.S.(non modular)bricks of class designation 7.5 each 196.40 139.00 27299.60

91 18.78 Making chases up to 7.5x7.5 cm in walls includingmaking good and finishing with matching surfaceafter housing G.I. pipe etc. metre 77.65 375.00 29118.75

92 19.10 Providing, laying and jointing glazed stonewarepipes class SP 1 with stiff mixture of cementmortar in the proportion of 1:1 (1 cement : 1 finesand) including testing of joints etc. complete :

a 19.1.2 150 mm diameter metre 301.90 274.00 82720.60b 19.1.3 200 mm diameter metre 447.25 285.00 127466.25c 19.1.4 250 mm diameter metre 676.75 122.00 82563.50d 19.1.5 300 mm diameter metre 747.90 88.00 65815.20

93 19.2' Providing and laying cement concrete 1:5:10 (1cement : 5 coarse sand : 10 graded stoneaggregate 40 mm nominal size) all-round S.W.pipes including bed concrete as per standarddesign:

a 19.2.2 150 mm diameter S.W. pipe metre 664.80 274.00 182155.20b 19.2.3 200 mm diameter S.W. pipe metre 774.95 285.00 220860.75c 19.2.4 250 mm diameter S.W. pipe metre 896.15 122.00 109330.30d 19.2.5 300 mm diameter S.W. pipe metre 1329.60 88.00 117004.80

94 19.3 Providing and laying cement concrete 1:5:10 (1cement : 5 coarse sand : 10 graded stoneaggregate 40 mm nominal size) up tohaunches of S.W. pipes including bedconcrete as per standard design :

a 19.3.2 150 mm diameter S.W. pipe metre 418.70 274.00 114723.80b 19.3.3 200 mm diameter S.W. pipe metre 492.15 285.00 140262.75c 19.3.5 250 mm diameter S.W. pipe metre 572.95 122.00 69899.90d 19.3.6 300 mm diameter S.W. pipe metre 661.10 88.00 58176.80

95 19.4 Providing and fixing square-mouth S.W. gully trapclass SP I complete with C.I. grating brickmasonry chamber with water tight C.I. cover withframe of 300 x300 mm size (inside) the weight ofcover to be not less than 4.50 kg and frame to benot less than 2.70 kg as per standard design :

19.4.1 100x100 mm size P type19.4.1.2 With Sewer bricks conforming to IS : 4885 each 1522.10 31.00 47185.10

16 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

96 19.6 Providing and Laying of non -pressure NP2class(light duty) R.C.C.pipe with collars jointedwith stiff mixture of cement mortar in proportion1:2(1 cement:2 Fine sand) including testing ofJoints etc complete.

a) 19.6.4 300 mm dia R.C.C Pipe metre 494.35 52.00 25706.20b) 19.6.5 450 mm dia R.C.C Pipe metre 688.90 870.00 599343.00c) 19.6.7 600 mm dia R.C.C Pipe metre 1358.65 215.00 292109.75d) 19.6.10 900 mm dia R.C.C pipe metre 1931.75 31.00 59884.25

97 19.16 Providing orange colour safety foot rest ofminimum 6 mm thick plastic encapsulated as perIS : 10910, on 12 mm dia steel bar conforming toIS : 1786, having minimum cross section as 23mmx25mm and over all minimum length 263 mmand width as 165 mm with minimum 112 mmspace between protruded legs having 2 mm treadon top surface by ribbing or chequering besidesnecessary and adequate anchoring projections ontail length on 138 mm as per standard drawingand suitable to with stand the bend test andchemical resistance test as per specifications andhaving manufacture's permanent identificationmark to be visible even after fixing, including fixingin manholes with 30x20x15 cm cement concreteblock 1:3:6 (1 cement : 3 coarse sand : 6 gradedstone aggregate 20 mm nominal size) completeas per design.

each 295.20 20.00 5904.00

98 19.18 Supplying and fixing C.I. cover without frame formanholes :

19.18.1 455x610 mm rectangular C.I. cover (light duty) theweight of the cover to be not less than 23 kg

each 1217.00 3.00 3651.00

99 19.19 Providing and fixing in posation precast RCCmanhole cover and frame of required shape andapproved quality.

a 19.19.1.1 LD 2.5 , Rectangular shape 600x450mm internaldimensions. each 1108.05 91.00 100832.55

b 19.19.3.1 HD-20 Circular shape 560 mm internal diameter.each 1492.05 35.00 52221.75

17 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

100 19.30 Constructing brick masonry chamber forunderground C.I. inspection chamber and bendswith bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty)455x610 mm internal dimensions, total weight ofcover with frame to be not less than 38 kg (weightof cover 23 kg and weight of frame 15 kg) R.C.C.top slab with 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size)foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cementmortar 1:3 (1 cement : 3 coarse sand) finishedsmooth with a floating coat of neat cement onwalls and bed concrete etc. complete as perstandard design :

19.30.1 Inside dimensions 455x610 mm and 45 cm deepfor single pipe line :

19.30.2.1 With common burnt clay F.P.S.(non modular)bricks of class designation 7.5 each 5159.50 58.00 299251.00

101 20.3 Boring, Providing and installing cast in situ singleunder reamed piles of specified diameter andlength below pile cap in M-25 cement concrete, tocarry a safe working load not less than specified,excluding the cost of steel reinforcement butincluding the cost of boring with bentonite solutionand the length of the pile to be embedded in pilecap etc. all complete. (Length of pile for paymentshall be measured upto to the bottom of pile cap) :

a 20.3.1 300mm dia piles. metre 2065.50 4896.00 10112688.00b 20.3.2 400mm dia piles. metre 2471.20 9344.00 23090892.80c 20.3.3 450 mm dia piles metre 2713.55 4104.04 11136517.74

102 20.4' Extra over item No. 23.3 for providing additionalbulb in under reamed piles, under specified diameter (Only the quantity of extra bulbs are to bepaid).

a 20.40.1 300 mm dia piles each 1417.30 758.00 1074313.40b 20.40.2 400 mm dia piles each 1599.25 1007.00 1610444.75c 20.40.3 450 mm dia piles each 1709.10 190.00 324729.00

103 20.6' Vertical load testing of piles in accordance with IS2911 (Part IV) including installation of loadingplatform and preparation of pile head orconstruction of test cap and dismantling of testcap after test etc. complete as per specification &the direction of Engineer in-charge.

20.6.1 Single pile upto 50 tonne capacity20.6.1.1 Initial Test Per Test 38561.80 43.00 1658157.40

104 20.8' Lateral load testing of single pile in accordancewith IS Code of practice IS : 2911 (Part IV) fordetermining safe allowable lateral load on pile :

20.8.1 Upto 50 tonne capacity pile Per Test 17422.50 43.00 749167.50

18 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

105 21.1' Providing and fixing aluminium work fordoor,window, ventilators and partitions withextruded built up standard tubular sections/appropriate Z sections and other sections ofapproved make conforming to IS :733 andIS:1285 Fixing with dash fastners of required diaand size, including necessary filling up the gaps atjunctions, i.e. at top bottom and sides withrequired EPDM rubber/neoprene gasket etc.Aluminium sections shall be smooth ,rustfree,straight, mitred and jointed mechanicallywherever required including cleat angle ,Aluminium snap beading forglazing/panelling,C.P.brass/stainless steelscrews,all complete as per architural drawingsand the directions of Engineer in charge.(Glazing,panelling and dash fastners to be paidseperately.)

a 21.1.1 For fixed portion21.1.1.2 Powder coated Aluminium(minimum thickness of

powder coating 50 microns) Kg. 373.00 1863.00 694899.00

b 21.1.2 For shutters,Doors, Windows and ventilatorsincluding providing and fixing hinges/pivots andmaking provision for fixing of fittings whereverrequired including the cost of EPDMrubber/neoprene gasket required(Fittings shall bepaid seperately)

21.1.2.2 Powder coated Aluminium(minimum thickness ofpowder coating 50 microns) Kg 427.60 4314.00 1844666.40

106 21.2 Providing and fixing 12 mm thick prelaminatedparticle board flat pressed three layer or gradedwood particle board conforming to IS: 12823Grade l Type ll, in panelling fixed in aluminumdoors, windows shutters and partition frames withC.P. brass / stainless steel screws etc. completeas per architectural drawings and directions ofengineer-in-charge.

21.2.2 Pre-laminated particle board with decorativelamination on both sides Sqm 1066.00 115.49 123112.34

107 21.3 Providing and fixing glazing in aluminium door,window, ventilator shutters and partitions etc. withEPDM rubber / neoprene gasket etc. complete asper the architectural drawings and the directionsof engineer-in-charge. (Cost of aluminium snapbeading shall be paid in basic item):

a 21.3.2 With float glass panes of 5.50 mm thickness sqm 1009.00 173.88 175444.92b 21.3.3 With float glass panes of 8 mm thickness sqm 1267.50 11.83 14994.53

108 21.8 Filling the gap in between aluminium frame &adjacent RCC/ Brick/ Stone work by providingweather silicon sealant over backer rod ofapproved quality as per architectural drawings anddirection ofEngineer-in-charge complete.

21.8.1 Upto 5mm depth and 5 mm width metre 83.05 1293.11 107392.79

19 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

109 21.13 Providing and fixing 100mm brass locks (bestmake of approved quality) for aluminium doorsincluding necessary cutting and making good etc.complete. each 386.60 56.00 21649.60

110 21.16 Providing and fixing aluminium round shapehandle of outer dia 100mm with SS screws etc.complete as per direction of Engineer in- charge

21.16.2 Powder coated minimum thickness 50 micronaluminium each 67.50 302.00 20385.00

111 26.7 Designing, fabricating, testing, installing and fixingin position Curtain Wall with Aluminium CompositePanel Cladding, with open grooves for linear aswell as curvilinear portions of the building , for allheightsand all levels etc. including:a) Structural analysis & design and preparation ofshop drawings for pressure equalisation or rainscreen principle as required, proper drainage ofwater to make it watertight including checking ofall the structural and functional design.

b) Providing, fabricating and supplying and fixingpanels of aluminium composite panel cladding inpan shape in metalic colour of approved shadesmade out of 4mm thick aluminium compositepanel material consisting of 3mm thick FR grademineral core sandwiched between two Aluminiumsheets (each 0.5mm thick). The aluminiumcomposite panel cladding sheet shall be coilcoated, with Kynar 500 based PVDF / Lumiflonbased fluoropolymer resin coating of approvedcolour and shade on face # 1 and polymer(Service) coating on face # 2 as specified usingstainless steel screws, nuts, bolts, washers,cleats, weather silicone sealant, backer rods etc.

c) The fastening brackets of Aluminium alloy 6005T5 / MS with Hot Dip Galvanised with serrationsand serrated washers to arrest the wind loadmovement, fasteners, SS 316 Pins and anchorbolts of approved make in SS 316, Nylonseparators to prevent bi-metallic contacts allcomplete required to perform as per specificationand drawingThe item includes cost of all material& labour

component, the cost of all mock ups at site, costof all samples of the individual components fortesting in an approved laboratory, field tests onthe assembled working curtain wall withaluminium composite panel cladding, cleaning andprotection of the curtain wall with aluminiumcomposite panel cladding till the handing over ofthe building for occupation. Base frame work forACP cladding is payable under the relevantaluminium items. The Contractor shall

20 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

material provide curtain wall with aluminiumcomposite panel cladding, having all theperformance characteristics all complete , as perthe Architectural drawings, as per itemdescription, as specified, as per the approvedshop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment,only the actual area on the external face of thecurtain wall with Aluminum Composite PanelCladding (including width of groove) shall bemeasured in sqm. up to two decimal places.

sqm 3696.65 500.00 1848325.00

112 22.40 Providing and placing in position sutiable waterstops conforming to IS: 12200 forconstruction/expansion joints between 2 RCCmembers and fixed to the reinforcement withbinding wire before pouring concrete etc.complete.

22.4.1 Serrated with central bulb (225mm wide,8-11mmthick) metre 489.45 315.00 154176.75

113 23.2 Supplying and stacking of good earth at siteincluding royalty and carriage up to 1 km (earthmeasured in stacks will be reduced by 20% forpayment). cum 308.35 109.63 33805.03

114 23.8 Spreading of sludge, dump manure and / or goodearth in required thickness as per direction ofOfficer-in-charge (Cost of sludge, dump manureand / or good earth to be paid separately).

cum 25.15 139.48 3507.92

115 23.9 Mixing earth and sludge or manure in the requiredproportion specified or directed by the Officer-in-charge. cum 17.25 249.11 4297.18

116 23.10 Grassing with selection No.1 grass includingwatering and maintenance of the lawn for 30 daysor more till the grass forms a thick lawn, free fromweeds and fit for mowing including supplying goodearth, if needed (the good earth shall be paid forseparately).

23.10.2 With grass Turf 100 Sqm634.30 105.00 66601.50

117 23.12 Uprooting rank vegetation and weeds by diggingthe area to a depth of 60cm, removing all weedsand other growth with roots by forking repeatedly,breaking clods, rough dressing, flooding withwater, uprooting fresh growths after 10 to 15 daysand then fine dressing for planting new grass,including disposal of all rubbish with all leads andlifts. 100 Sqm 2887.60 470.44 1358442.54

21 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

118 23.13 Preparation of beds for hedging and shrubbery byexcavating 60 cm deep and trenching theexcavated base to a further depth of 30 cm,refilling the excavated earth after breaking clodsand mixing with sludge or manure in the ratio of8:1 (8 parts of stacked volume of earth afterreduction by 20% : one part of stacked volume ofsludge or manure after reduction by 8%), floodingwith water, filling with earth if necessary, wateringand finally fine dressing, leveling etc. includingstacking and disposal of materials declaredunserviceable and surplus earth by spreading andleveling as directed, within a lead of 50 m, lift upto 1.5 m complete (cost of sludge, manure orextra earth to be paid for separately).

cum 105.20 219.26 23066.57

119 23.14 Digging holes in ordinary soil and refilling thesame with the excavated earth mixed with manureor sludge in the ratio of 2:1 by volume (2 parts ofstacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reductionby 8%) flooding with water, dressing includingremoval of rubbish and surplus earth, if any, withall leads and lifts (cost of manure, sludge or extragood earth if needed to be paid for separately) :

23.14.2 Holes 90 cm dia, and 90 cm deep each 90.90 195.00 17725.5023.14.4 Holes 45 cm dia, and 45 cm deep each 12.15 3932.00 47773.80

120 23.16 Providing and fixing M.S. flat iron tree guard 60cm dia and 2 m high, above ground consisting 4nos 25 x 6 mm, 2.25 m long and 8 nos 25 x 3 mm2 m long verticals M.S. flats, riveted to 3 nos 25 x6 mm M.S. flat iron rings in two halves, fixingtogether at site with required six numbers of 8 mmdia. and 30 mm long bolts, including painting twocoats with synthetic enamel paint of approvedbrand and manufacture over a coat of primer. Onename plate of 1 mm thick M.S. sheet of size250x100 mm shall be welded to the tree guardnear the middle height and lettered CPWD / PWD/any other approved name. The tree guard shall besuitably fixed to the ground by embedding fourlegs of tree guard in pits of suitable dia and to adepth of 25 cm, refilling the pits with soil andramming, complete in all respect as persatisfaction and direction of Officer-in-charge.

each 2884.15 195.00 562409.25

121 23.25 Supplying and stacking of well decayed cow dungmanure at site including royalty and carriage upto1 km (Cow dung manure measured in stacks willreduced by 8% for Payment).

cum 190.40 249.11 47430.92

Total 331113033.85

22 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

Non Schedule Items

Civil Works

NS 1 Supplying and filling local fine sand in trenches,plinth, under floor, including watering, ramming,consolidating, dressing, royality, leads and liftscomplete as per requirement of the work.

cum 95248.92

NS 2 A Supply and stacking of Selection Grass carpetcomplete in all respectas per requirement of thework. sqm 105.00

B Supply, stacking and plantation of following treescomplete at complete in all respectas perrequirement of the work.: -

(i) Plyalthia Longifolia - 2 Mtr height and 5 cm girth

each 141.00(ii) Saraca Indica 2 Mtr height and 5 cm girth

each 13.00(iii) Casia Fishtula 2 Mtr height and 5 cm girth

each 12.00(iv) Washingtonia Palm - 2 Mtr Height

each 6.00(v) Bismarkia Palm

each 3.00(vi) Latina Rubra

each 3.00(vii) Raphis Palm

each 4.00(viii) Brassia Actinophylla

each 3.00(ix) Caryota Urens

each 3.00(x) Dracaena Victoria

each 3.00(xii) Juniprus American

each 4.00

23 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

C Supply, stacking, installation and preparion of bedetc. complete at site for following ground plants: -

(i) Lantana Sellowiana

each 1301.00(ii) Schefflera Hicolor

each 138.00(iii) Acalypha Colorata

each 249.00(iv) Asparagus Millei

each 226.00(v) Dracaena Varnicii

each 267.00(vi) Aspidistra Lurida

each 284.00(vii) Ferns (Nephrolepis)

each 158.00(viii) Spathyiphylum

each 255.00(ix) Sparagus Plumosis

each 73.00

NS 3 Providing and laying laterite stone blocks masonrywith 250 mm thick locally avaliable laterite stoneblocks in superstructure above plinth level incement mortar 1:4 complete in all respects, forproper completion of the work.(The mode ofmeasurement shall be sa that of Brick Work inaccordance withCPWD specification)

cum 526.00

NS 4 Supplying and filling in plinth under floors withCoarse sand after mixing with3% hydrated limeby volume including watering, ramming,consolidating and dressing complete, for propercompletion of the work. cum 23045.30

24 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 5 Providing and laying 100 mm thick factory madehigh strength solid concrete 200x100x100 withchamfared edges on top cement concrete blockof M- 50 grade made by hydraulic concrete blockmaking machine with strong vibratory compactionand of approved size and design / shape laid inOrdinary Grey Colour and pattern over andincluding average, 50 mm thick ompacted bed ofcoarse sand, filling the joints with fine sand inharring bone pattearn etc, all complete as perdirections of Engineer-in-Charge for Heavy TrafficAreas such as Bus terminals, Industrialcomplexes, mandi houses, roads on expansivesoils, factory floor, service stations, Industrialpavements,complete in all respect for propercompletion of the work.

sqm 24040.00

NS 6 Providing and laying 100 mm thick factory madehigh strength solid concrete 200x100x100 withchamfared edges on top cement concrete blockof M- 50 grade made by hydraulic concrete blockmaking machine with strong vibratory compactionand of approved size and design / shape laid inDark Fast Colour and pattern over and includingaverage, 50 mm thick compacted bed of coarsesand, filling the joints with fine sand in harringbone pattearnetc, all complete as per directions of Engineer-in-Charge for Heavy Traffic Areas such as Busterminals, Industrial complexes, mandi houses,roads on expansive soils, factory floor, servicestations, Industrial pavements,complete in all

sqm 8014.00

NS 7 Anti-skid floor tiles 10mm thick in flooring in12.5mm thick cement plaster 1:3 in base andjointed with white cement slurry in joints includingcorners angles and beading.complete in allrespects, for proper completion of the work.

sqm 413.40

NS 8 Anti-skid tiles in skirting, dado and risers of stepsin 20 mm thick cement plaster 1:3 in base andjointed with white cement slurry in joints includingcorners angles and beading.complete in allrespects, for proper completion of the work.

sqm 41.34

NS 9 Supply and erection of Roof sheeting of regularmodified polyster colour coated steel sheets 0.50mm thick (TCT). The 32 mm depth with antiCapiliary groove to make it leak proof (550 Mpayield strength , and manufactured as per IS - 513)with hot galvanied CRCA steel base metal havingmass of 120 GSM as per IS: 277. The externalside shall have 20 micron colour coating of SMPand internal side a backing coat over epoxyprimer. The screw used for fixing shall be selfdrilling and self tapping , and confirm to standardsuch as As 3566 class 3. Sqm 11850.14

25 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 10 Providing and fixing at or near ground level factorymade RCC pavement slab of M-30 grade of size450x450x50 mm, including reinforcement with 6mm dia M.S. bars 4 nos on each side, includingsetting in position over MS structure under flooringcomplete as per directions of the engineer-in-charge. sqm 711.55

NS 11 Supply and erection of Roof sheeting ofpolycarbonate (transparent sheets) 2 mm thick forskylight complete in all respects as perspecifications of the Manufacturer, and as perarchitectural drawing & as per the direction of theEngineer-in-charge.

Sqm 144.72

NS 12 Design, supply and erection of guttersmanufactured out of High tensile galvalume steelto required lengths as per designed profile andsize . The steel shall be high tensile 550 Mpayield strength , and manufactured to As 1397standard. The external side shall have 20 microncolour coating of SMP and internal side a backingcoat over epoxy primer. The end laps shall bejoined using nut bolts and the gutter straps shallbe fixed using self drilling and self tapping screws3.complete in all respects, for proper completionof the work.

sqm 1806.96

NS 13 Design, supply and erection of factory formedrectangular downpipes of size 150 x 150 mm or as per site requirement and approved by theEngineer-in-charge manufactured out ofprepainted galvanised steel to required lengthsThe steel shall be high tensile 240 Mpa yieldstrength , and manufactured to IS 2728 standard.The external side shall have 20 micron colourcoating of SMP and internal side a backing coatover epoxy primer.

Metre 757.50

26 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 14 Supply and fixing of shilkhar on top of temple typeshed (Shikhar / dome) fabricated of FRP 12 mmthick as per manufacturer's specifications and asper architectural drawings complete in all respectsto be fixed at 18 mtr height as per directions of theEngineer-in-charge.

FRP Shikhar

each 2.00

NS15 Providing and fixing in position best indian makeC.P.Jet complete in all respects.

each 74.00

NS 16 Providing Drip Seal joints to sand castiron/centrifugally cast (spun) iron pipes and fittingsof diameter:complete in all respects, for propercompletion of the work.

a) 100 mm

each 226.00b) 75mm

each 205.00

NS 17 Providing and fixing in position best indian make32mm I/d CP Bottle trap viking/jaquar makecomplete in all respects, for proper completion ofthe work. each 72.00

NS 18 Providing and fixing G.I.waste pipe 32mm of jindalhissar/tata make up to floor trap inc.2Nos elbowsAVR/SVW make,chiseling complete in allrespects, for proper completion of the work.

each 72.00

NS 19 Providing and fixing white vitreous china ware starwhite colour under counter wash hand basin ofsize 56 x 43 cm Hind ware make modelno.10049 or any equivalent make parry ware etcas per instruction of E.I.C including the cost ofwiking make cp 32mm waste, chair typeadjustable brackets, jaquar 167B/nova makecentral hole mixer including the cost of cuttinggranite for WHB and making hole in granite forfixing mixer, plugs.screws,white cement, completein all respects, for proper completion of the work.

each 63.00

NS 20 Providing & fixing CP brass shower 10" roundviking make or any equvalent make with showerarm complete in all respect, for proper completionof the work. each 6.00

27 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 21 Providing and fixing in position best indian make32mm I/d CP Bottle trap viking/jaquar makecomplete in all respects., for proper completion ofthe work. each 38.00

NS 22 Providing and fixing G.I.waste pipe 32mm of jindalhissar/tata make up to floor trap inc.2Nos elbowsAVR/SVW make,chiseling complete in allrespects, for proper completion of the work.

each 38.00

NS 23 Providing and fixing in position best indian make5mm thick mirror mounted on water proof plyPVC sheet ground fixed in position bt means of 4no's chromium plated brass screw and washersincluding the cost of wooden/ fibre beedingalround complete in all respects, for propercompletion of the work. each 41.50

NS 24 Providing and fixing G.I. Tank nipple AVR/SVWMake complete in all respects,for propercompletion of the work.

a) 20 mm nominal bore

each 42.00b) 25 mm nominal bore

each 42.00

NS 25 Providing and fixing in posation best Indian makeISI marked ball cock 25mm withbrass rod,PVCball complete in all respect,for proper completionof the work. each 23.00

NS 26 1-1/2'' Stainless steel grab Bar with concieledmounting flange complete in all respect,for propercompletion of the work. each 2.00

NS 27 Providing laying, jointing, cutting and testing G.I.pipe lines and specials tees bends, sockets,elbows etc. Including the cost of excavationcomplete in all respects,for proper completion ofthe work.

Lum Sum per

job 1.00

NS 28 Providing and installing clear water pumping setsincluding the cost of one set as stand byarrangement complete in all respects,for propercompletion of the work. a) 2 set of 50.00 BHPeach with 60 mt.. Head

Nos of 50 BHP 2.00

Add cost of silver ionization disinfactor No. 1.00-

28 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 29 Design, supply, engineering, construction,fabrication and supply of one unit packaged typeskid mounted sewage treatment plant of capacity160 Cum per day which includes the following: -

each 1.001. Preliminary treatment unit a) bar screen - 1 No.b) Inlet chamber - 1 Noc) Grit Chjamber - 1 Nod) Aeration grid for sewerage collection tank -- 1Lote) Course diffusers for sewerage collection tank -1lot2. Secondary Treatment Unit (skid mounted unit) including a) Sewage lift pump set - 2 Nos.b) Aeration grid for MBBR reactor - 1 Lotc) Air difuser - 1 Lotd) MBBR media - 1 Lote) Secondary tube settler Media - 1 Lotf) Urea dosing tank - 1 No.g) Dap dosing tank - 1 Noh) Air blower with accessories -2 Nosi) Sludge recirculation pum- 1 Noj) Centralized Control Panel - 1 Nok) Cabling - 1 Lot

l) Interconnecting piping, fittings & valves - 1 Lot3. Tertiary treatment (Polishing unit ) includinga) Filter feed tank - 1 Nob) Filter feed pump - 2 Noc) Pressure sand filter - 1 Nod) Activated carbon filter - 1 Noe) Hypodisinfection dosing tank and dosing pump - 1No eachf) Treated water tank - 1Nog) Treated water transfer pump - 2 No.4. Mechanical sludge dewatering systema) Sludge feed pump - 2 Nob) Sludge holding tank -1 Noc) Aeration grid for sludge holding tank - 1 Lotd) Air diffuser for sludge holding tank -1 Lote) Polyelctrolyte Dosing systems - 1 Nof) Filter press - 1 No4. Instrumentations includinga) Pressure gauges - 1 Lotb) Level switches - 1 Lotc) Water meter - 1 NoRates includes erection and commissioning etc. complete.

NS 30 Providing and fixing G.I.pipes complete with G.I.fittings including trenching and refilling etc.,forproper completion of the work. Complete in allrespect, for proper completion of the work. 100mm dia. metre 47.00

29 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 31 Providing laying, jointing, cutting and testing G.I.pipe lines and specials tees bends, sockets,elbows etc. Including the cost of excavationcomplete in all respect, for proper completion ofthe work.

Lum sum

1.00

NS 32 Providing and fixing C.I sluice valves (with Cap)complete with bolts, nuts, rubber insertions etc.,for proper completion of the work. (the tail piecesif required will be paid separately):

a) 50mm internal diameter

each 6.00b) 80mm internal diameter

each 5.00

NS 33 Constructing masonry chamber 90x90x100cminside with 75 class designation brick work incement mortar 1:4 (1 cement : 4 coarse sand forsluice valve , with C.I surface box 100mm. Topdiameter, 160mm bottom diameter and 180mmdeep (inside) with chained lid and RCC top slab1:2:4 mix (1 cement : 2 coarse sand : 4 gradedstone aggregate 20mm nominal size) necessaryexcavation foundation concrete 1:5:10 (1 cement :5 fine sand : 10 graded stone aggregate 40mmnominal size) and inside plastering with cementmortor 1:3 (1 cement : 3 coarse sand ) 12mmthick finished witha floating coat of neat cementcomplete as per standard design:

With F.P.S. bricks each 12.00

Fire Fighting Works

NS 34 2 Providing, Installation, Testing & commissioning of MS pipes (CLASS 'C')

a) 150mm dia.(For Suction header)

Metre 10.00b) 100mm dia.

Metre 8.00c) 80mm dia.

Metre 6.00d) 50mm dia

Metre 5.00e) 25mm dia.

Metre 3.00

30 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 35 Providing, Installation, Testing andcommissioning of 'C' CLASS heavy MS pipesin ground

Providing, Installation, Testing and commissioningof following sizes ISI marked 'C' class heavyM.S. pipes including cutting, screwing, weldingetc. and providing all fittings such as elbows,reducers, flanges, gaskets, nuts, bolts andwashers etc. including applying with one coat ofreadymix primer, wraping the pipe with wrapingtape of IWL/Cotek makes, laying the pipe so thatthe top of the pipe is at a depth of Min. one meterbelow ground level. Make Jindal/ Tata/ Surya.100mm dia.

Metre 800.00

NS 36 SLUICE VALVEProviding, fixing and Testing of Double flangedSLUICE VALVE of PN. 1.6 with Non risingspindle, bronze/ gun metal / SS seat , ISI Markedcomplete with nuts, bolts, washers, gaskets a) 100mm dia Each 6.00

b) 150mm dia Each 2.00

NS 37 SITC of cast iron flanged Non return valves

Supplying, Installation, Testing andCommissioning of cast iron flanged wafer typeNon return valves of PN 1.6 rating of followingsizes conforming to relevent IS specifications andproviding and fixing nuts, bolts, wahsers, gasketsetc. complete as required.

a) 80mm dia

Each 2.00b) 100mm dia

Each 2.00b) 150mm dia

Each 2.00

NS 38 SITC of ball valves/gate valveProviding and fixing brass ball valves with brassbody nickel coated, brass ball, hard chromeplated, suitable for fire fighting complete in allrespects.

a) 25mm dia Each 2.00

31 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 40 SITC of Cast iron flanged Y strainer

Supplying, Installation, Testing andCommissioning of CI body flanged (both ends)type Y strainer with (stainless steel / brass mesh)conforming to relevant IS specifications amendedupto date complete including providing and fixingnuts, bolts, washers, gaskets etc. complete asrequired.

a) 150 mm dia. Each 2.00

NS 41 8 SITC of pressure switchesSupplying, Installation, Testing andCommissioning of pressure switches suitable foroperating with fire hydrant systems for workingpressure of 8.8 Kg/cm² including electricalcontrol wiring with suitable copper conductor PVCinsulated and sheathed control cable upto controlpanel, connections etc. complete as required.

Each 3NS 42 9 2 WAY FIRE BRIGADE INLET CONNECTION

Providing, fixing and Testing of 2 WAY FIREBRIGADE INLET CONNETION of cast iron bodywith 2 No's , SS male instantaneous inlet couplingcomplete with cap and chain as required for150mm dia MS pipe connection , conforming to IS904 as required . (Make : GETECH/ MINIMAX/GEI) Each 4

NS 43 10 YARD HYDRANT 63mm DIA VALVEProviding & Fixing of Yard hydrant 63 mm diavalve instantaneous female coupling on the outletcomplete with flanges ,cap and chain ISImarked.(Make : GETECH/ MINIMAX /GEI) Each 16

NS 44 SITC of AIR VESSELSupplying, Installation, Testing andCommissioning of air cushion tank (Air vessel)200mm dia. & 1200mm height having dished endsmade of 8mm thick M.S.Pipe, and providing25mm dia. ball type brass air release valve ,Safety valve, Pressure gauge, suitableM.S.support and minor civil works etc. asrequired. Each 1

NS 45 Providing, fixing, testing & commissioning of 100mm dia Bourden type, Stainless Steel dial typepressure gauge including brass isolation valveand pipe having caliberation of 0-15 Kg/cm2.

Each 4

NS 46 SITC of 4.5kg, CO2 fire extinguisher

Supplying, Installation, and Testing ISI markedCO2 fire extinguisher of 4.5 Kgs. capacity completwith discharge horn and mounting it on the wallwith a suitable MS bracket (including S/F bracket)minor civil works etc. complete as required.

Each 22

32 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 47 Supplying, Installation, and Testing ISI markedABC fire extinguisher of 6 Kgs. capacity completwith discharge horn and mounting it on the wallwith a suitable MS bracket (including S/F bracket)minor civil works etc. complete as required.

Each 22

NS 48 SITC OF MAIN FIRE PUMP SETSupplying, Installation, Testing andCommissioning of ELECTRIC MOTOR DRIVEN,horizontal split casing, centrifugal fire dutyoperation pump, (with mechanical seal, bronzeimpeller & carbon steel EN-8 shaft) capable for aDISCHARGE of 2280 L.P.M. at a HEAD of 50MTRS., coupled through flexible coupling (i/ccoupling guard) with totally enclosed, fan cooledsquirrel cage 4 pole induction motor suitable foroperation on three phase AC supply of 415 + 10%Volts, 50 Hz, fixing the coupled pump and motoron a common structural base frame, making asuitable cement concrete foundation andmounting the complete pump-motor set on thefoundation using suitable numbers of anti vibrationmountings as per the design / recommendationsof the manufacturer .Pump : - Make Kriloskar -CI construction, Glandpacked arrangement, 150mm suction. And100mm delivery Moter:- Make - Kriloskar,40HP, for 50m head

Each 1

NS 49 SITC OF DIESEL ENGINE DRIVEN PUMP SET

Supplying, Installation, Testing andCommissioning of Diesel Engine driven PumpSets single stage horizontal split casing,centrifugal pumping set with bronze impeller andcast iron volute coupled with water cooled Dieselengine capable for a DISCHARGE of 2280 L.P.M.at a HEAD of 50 MTRS.,with automatic startingmechanism, batteries, automatic batteriescharger, fuel tank, silence exhaust& all standardaccessories connected, through a flexiblecoupling & coupling guard mounted on baseframe complete in all respect. Recommendationsof the manufacturer.Pump: - Make Crompton with CI construction,Gland packed arrangementMoter:- Make - Kriloskar, 40HP, for 50m head

Each 1

33 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

NS 50 SITC OF JOCKEY FIRE PUMP

Supplying, Installation, Testing andCommissioning of ELECTRIC MOTOR DRIVEN,horizontal end suction type, centrifugal fire dutyoperation pump, (with mechanical seal, bronzeimpeller and carbon steel EN-8 shaft) capable fora DISCHARGE of 180 L.P.M. at a HEAD of 50MTRS., coupled through flexible coupling (i/ccoupling guard) with totally enclosed, fan cooledsquirrel cage 4 pole induction motor suitable foroperation on three phase AC supply of 415 + 10%Volts, 50 Hz, fixing the coupled pump and motoron a common structural base frame, making asuitable cement concrete foundation andmounting the complete pump-motor set on thefoundation using suitable numbers of anti vibrationmountings as per the design / recommendationsof the manufacturer.Pump : - Make Kriloskar, CI construction,Gland packed arrangementMoter:- Make - Kriloskar, 10HP, for 50m head

Each 1

NS 51 18 FIRE/PUBLIC HEALTH PANEL a) Supply, installation and commissioning at site of

cubical type panel fabricated out of 14/16swg rustinhibited steel sheet complete with in coming busbar. Panel being free standing type shall be totallyenclosed dust and vermin proof enclosedconstruction with rubber gasket wall mountedpanel shall be provided with ISMC mountedchannels. The panel shall also have GI earth bus-bar, bus-bar chamber inter connection with solidbars/PVC insulated wires made by CPRI approved manufacturer as per requirement. Panel shall bepainted two coats of powder coated paint (Greyshade) over the primer. Panel shall also beprovided with name plate, designation of in-coming and out going circuits and shall havehinged lockable doors. Panel shall be installed onthe floor with suitable grouting bolt of suitable sizefor the following fittings / instruments.(REFERTHE QUANTITY WITH THE SLD)

Each 1INCOMIER

i 160AMP MCCB, TP, 35kA with rotory handle- 01 NOS

II R-Y-B Phase indicator set IED type -1 Set

iii CT150/5A, burden 15VA, class 1.0 -3 Nos

iv Digital Multifunctional Meter (V,A,F) -1v 2A SP MCB with Neutral Link 3 Nos

34 of 35 Abstract of Cost

S.NO REF. TO DSR 2013

UNIT Rate Quantity Amount

B BUS BARi Aluminium busbar 1600 amp TPN with colour

coded sleeves, 1 set C OUTGOING i MCCB 3 pole 125 amp 25 ka with rotary handles

and 40HP DOL motor starter, ON/OFF pushbutton , ON/OFF indication lamp (Green & Red),2A SP MCB (1) for control system-1 Nos

ii MCB TPN 63 amp 10 ka with 10HP DOL motorstarter, ON/OFF push button , ON/OFF indicationlamp (Green & Red), 2A SP MCB (1) for controlsystem & suitable range Over Load Thermal type -1 Nos

NS 52 Providing and laying vitrified floor tiles 300 X 300mm in sizes 10 mm thick IS: 4457 : 2007 withwater absorption less than 0.6% and conformingto IS : 15622, of approved make, in all colours andshades, laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand), including grouting thejoints with white cement and matching pigmentsetc., complete.

Sqm 7647.71

NS 53 Providing and laying Vitrified tiles 300 x 300 mmor in different sizes, 10 mm thick, with waterabsorption less than 0.6% and conforming to I.S.15622, of approved make, in all colours & shade,in skirting, riser of steps, over 12 mm thick bed ofcement mortar 1:3 (1 cement: 3 coarse sand),including grouting the joint with white cement &matching pigments etc. complete.

Sqm 4010.25

NS 54 Providing and laying vitrified floor tiles 100 X 100mm in sizes 12 mm thick IS: 4457 : 2007 withwater absorption less than 0.6% and conformingto IS : 15622, of approved make, in all colours andshades, laid on 20mm thick cement mortar 1:4 (1cement : 4 coarse sand), including grouting thejoints with white cement and matching pigmentsetc., complete.

Sqm 2850.76

Total

35 of 35 Abstract of Cost

S. No. DSR-2013 Code No.

DESCRIPTION QTY UNIT RATE AMOUNT (Rs.)

DSR 2013 Electrical Items A DBs AND INTERNAL WIRING

1.0 WIRING IN PVC CONDUIT1.01 1.10 Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 sq mm FRLS

PVC insulated copper conductor single core cable in recessed medium class PVCconduit with modular switch, modular plate, suitable size GI box and earthing the pointwith 1.5 sq mm FRLS PVC insulated copper conductor single core cable Iincluding GIFan Box, Concealed Light Box Bell Push & 5/6A Switch single pole etc complete asrequired.

i 1.10.3 Group C 450 Point 727.00 327150.001.02 1.12 Wiring for light/ power plug with 2 x 4 sq mm FRLS PVC insulated copper conductor

single core cable in recessed medium class PVC conduit along with 1 No. 4 sq mm FRLSPVC insulated copper conductor single core cable for loop earthing as required.

2500 Metre 171.00 427500.00

1.03 1.13 Wiring for light/ powewr plug with 4 x 4 sq mm FRLS PVC insulated copper conductorsingle core cable in recessed medium class PVC conduit along with 2 No. 4 sq mm FRLSPVC insulated copper conductor single core cable for loop earthing as required.

3000 Metre 278.00 834000.00

1.04 1.14 Wiring for circuit/ submain wiring along with earth wire with following szes of FRLSPVC inslated copper conductor, single core cable in recessed medium class conduit asrequired

i 1.14.2 2 x 2.5 sq mm + 1 x 2.5 sq mm as earth wire 400 Metre 140.00 56000.00ii 1.14.4 2 x 6.0 sq mm + 1 x 6.0 sq mm as earth wire 300 Metre 216.00 64800.00iii 1.14.5 2 x 10.0 sq mm + 1 x 10.0 sq mm as earth wire 200 Metre 320.00 64000.00iv 1.14.7 4 x 2.5 sq mm + 2 x 2.5 sq mm as earth wire 300 Metre 214.00 64200.00v 1.14.9 4 x 6.0 sq mm + 2 x 6.0 sq mm as earth wire 200 Metre 371.00 74200.00vi 1.14.10 4 x 10.0 sq mm + 2 x 10.0 sq mm as earth wire 200 Metre 575.00 115000.00

1.05 1.18 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated anealed copperconductor, unarmored telephone cable in the existing recessed PVC conduit asrequired.

i 1.18.2 2 Pair 800 Metre 17.00 13600.00ii 1.18.3 4 Pair 100 Metre 26.00 2600.00

1.06 1.19 Spplying and drawing co-exial TV cable RG-6 grade, 0.7 mm solid copper conductor PEinsulated, shielded with fine tinned copper braid and protected with PVC sheath in theexisting recessed PVC conduit as required.

100 Metre 23.00 2300.00

BILL OF QUANTITY

1.07 1.53 Supplying and drawing of UTP 4 Pair CAT 6 LAN Cable in the existing surface /recessedsteel/PVC conduitt as required.

300 Metre 31.00 9300.00

2.0 1.21 Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in recess including cvutting the wall and making good the same in case ofrecessed conduit as required.

i 1.21.1 20 mm 100 Metre 64.00 6400.00ii 1.21.2 25 mm 1000 Metre 72.00 72000.00iii 1.21.3 32 mm 500 Metre 91.00 45500.00iv 1.21.4 40 mm 200 Metre 117.00 23400.00v 1.21.5 50 mm 200 Metre 152.00 30400.00

3.0 1.24 Supplying and fixing following modular switch/socket on the existing modular plate &switch box including connections but excluding modular plate etc. as required.

i 1.24.1 5/6 amps switch 112 Each 77.00 8624.00ii 1.24.3 15/16 amp switch 125 Each 114.00 14250.00iii 1.24.4 3 pin 5/6 amp socklet outlet 112 Each 101.00 11312.00iv 1.24.5 6 pin 15/16 amp socklet outlet 125 Each 163.00 20375.00v 1.24.6 Telephone socket outlet 16 Each 92.00 1472.00vi 1.24.7 TV antenna socket outlet 2 Each 94.00 188.00vii 1.24.8 Bell Pusht 2 Each 105.00 210.004.0 1.25 Supplying and fixing stepped type wlectronic fan regulator on the existing modular

plate switch box including connections but exclding modular plate etc. as required290 Each 362.00 104980.00

5.0 1.26 Supplying and fixing modular blanking plate on the exixting modular plate & switch boxexcluding modular plate as required.

50 Each 23.00 1150.00

6.0 1.33 Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box includingconnection etc complete as required. (White Colour for exhaust fan point)

22 Each 42.00 924.00

7.0 1.34 Supplying and fixing brass batten /angle holder including connection etc. complete asrequired (White colour)

10 Each 64.00 640.00

8.0 1.38 Supplying & fixing call bell/ buzzer suitable for single phase, 230Volta, complete asrequired.

2 Each 60.00 120.00

9.0 1.27 Supplying and fixing following sizes / modules, GI box along with Modular base & coverplate for modular switches in recess etc as required. (for Light Plug Socket & PowerSocket)

i 1.27.1 1 or 2 Module (75 mm x 75 mm) 20 Each 159.00 3180.00ii 1.27.2 3 Module (100 mm x 75 mm) 205 Each 172.00 35260.00iii 1.27.3 4 Module (125 mm x 75 mm) 40 Each 197.00 7880.00

iv 1.27.4 6 Module (200 mm x 75 mm) 40 Each 241.00 9640.00v 1.27.5 8 Module (125 mm x 125 mm) 20 Each 271.00 5420.00vi 1.27.6 12 Module (200 mm x 150 mm) 5 Each 365.00 1825.00

10.0 MCCB, MCB & DB’S10.01 2.3 Supplying and fixing following way, single pole and neutral, sheet stee, MCB

Distribution Board, 240 Volts, on recess, complete with tinned copper bus-bar, neutralbus-bar, earth bus-bar, din bar, interconnections, powder painted including earthingetc. as required. (But without MCB/RCCB/Isolator)

i 2.3.8 2 + 12 Way, Double Door 8 Each 1185.00 9480.0010.02 2.4 Supplying and fixing following way, horizontal type three pole and neutral, sheet stee,

MCB Distribution Board, 415Volts, on recess, complete with tinned copper bus-bar,neutral bus-bar, earth bus-bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator)

i 2.4.4 4 Way (4 + 12), Double Door 15 Each 1833.00 27495.00ii 2.4.5 6 Way (4 + 18), Double Door 3 Each 2265.00 6795.00iii 2.4.6 8 Way (4 + 24), Double Door 9 Each 2795.00 25155.00

10.03 2.6 Supplying and fixing following ways surface /recess mounting, vertical type, 415 volts,TPN MCB distribution board of sheet steel, dust protected, duly powder painted,inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din barfor mounting MCB`s with provision of 100 amps TP 16kA MCCB as incomer,interconnection between incomer MCCB and bus bars (but without MCB`s/MCCB) asrequired.

i 2.6.3 12 Way TP 3 Each 9075.00 27225.0010.04 2.10 Supplying & fixing 5A to 32A rating, 240/415v, Curve-C, bc-10ka, miniature circuit

breaker suitable for inductive load of following poles in the existing MCB DB completewith connections, testing and commissioning etc. as required.

i 2.10.1 Single Pole 588 Each 146.00 85848.00ii 2.10.4 Tripple Pole 36 Each 610.00 21960.00

10.05 2.14 Supplying & fixing followin rating, double pole (single phase and neutral), 240Volts,Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 300ma in theexisting MCB DB complete with connections, testing, and commissioning etc. asrequired

i 2.14.2 40 amps 8 Each 1510.00 12080.0010.06 2.15 Supplying & fixing followin rating,four pole (Three phases and neutral), 415Volts,

Residual Current Circuit Breaker (RCCB), having a sensitivity current upto 300ma in theexisting MCB DB complete with connections, testing, and commissioning etc. asrequired

ii 2.15.2 40 amps 14 Each 1845.00 25830.00iii 2.15.3 63 amps 17 Each 2128.00 36176.00

10.07 2.2 Providing and fixing following rating and breaking capacity and pole MCCB in existingcubicle panel board including drilling holes in cublcle panel, making connections, etc. asrequired.

i 2.2.1 100 Amp, 16 KA,TPMCCB 3 Each 3032.00 9096.0010.08 2.20 Supplying and fixing 30 Amps. 415 volrs, TPN insutrial type socket outlet, with 4 pole

and earth, metal enclosed plug top alongwith 30 amp. "C" TPMCB in sheet steelenclosure, on surface or in recess, with chained metal cover for the socket out let andcomplete with connections, testing and commissioning etc. as required.

3 Each 2156.00 6468.00

11.0 2825 Supply of 20 mm dia. G.I. pipe (medium class) for ceiling fan down rod. 200 Metre 103.49 20698.00B LT CABLES

MV CABLE LAYINGLaying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KVgrade of following size direct in ground including excavation, sand cushioning,protective covering and refilling the trench etc as required.

i 7.1.1 Upto 35 sq. mm 5000 Metre 181.00 905000.00ii 7.1.2 Above 35 sq. mm and upto 95 sq. mm 200 Metre 188.00 37600.00iii 7.1.3 Above 95 sq. mm and upto 185 sq. mm 100 Metre 195.00 19500.00iv 7.1.4 Above 185 sq. mm and upto 400 sq. mm 100 Metre 215.00 21500.00

13.0 7.2 Laying of one number additional PVC insulated and PVC sheathed / XLPE power cableof 1.1 KV grade of following size direct in ground in the same trench in one tierhorizontal formation including excavation, sand cushioning, protective covering andrefilling the trench etc as required.

i 7.2.1 Upto 35 sq. mm 3000 Metre 124.00 372000.00ii 7.2.2 Above 35 sq. mm and upto 95 sq. mm 150 Metre 131.00 19650.00iii 7.2.3 Above 95 sq. mm and upto 185 sq. mm 50 Metre 138.00 6900.00iv 7.2.4 Above 185 sq. mm and upto 400 sq. mm 30 Metre 159.00 4770.00

14.0 7.5 Laying of one number PVC insulated and PVC sheathed/XLPE powerr cable of 1.1 KVgrade of following size in the existing RCC/HUME/ METAL/PVC pipe

i 7.5.1 Upto 35 sq. mm 2000 Metre 15.00 30000.00ii 7.5.2 Above 35 sq. mm and upto 95 sq. mm 150 Metre 23.00 3450.00iii 7.5.3 Above 95 sq. mm and upto 185 sq. mm 100 Metre 30.00 3000.00iv 7.5.4 Above 185 sq. mm and upto 400 sq. mm 50 Metre 53.00 2650.00

15.0 7.8 Laying and fixing of one number PVC insulateed and PVC sheathed/XLPE power cableof 1.1KV grade of following size on cable tray as required.

i 7.8.1 Upto 35 sq. mm (clamped with 1mm thick saddle) 5800 Metre 19.00 110200.00

12.0 7.1

ii 7.8.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) 250 Metre 44.00 11000.00iii 7.8.3 Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)

50 Metre 54.00 2700.00iv 7.8.4 Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) 20 Metre 84.00 1680.00

16.0 9.1 END TERMINATIONSupplying and making indoor end termination with brass single compression gland andaluminium lugs for following sizes of PVC insulated PVC sheated XLPE aluminiumconductor cable of 1.1 KV grade as required.

i 9.1.31 3½ X 400 sq. mm (82mm) 4 Each 1203.00 4812.00ii 9.1.25 3½ X 120 sq. mm (45mm) 2 Each 417.00 834.00iii 9.1.24 3½ X 95 sq. mm (45mm) 4 Each 401.00 1604.00iv 9.1.23 3½ X 70 sq. mm (38mm) 4 Each 324.00 1296.00v 9.1.34 4 X 25 sq. mm (28mm) 6 Each 211.00 1266.00vi 9.1.33 4 X 16 sq. mm (28mm) 120 Each 208.00 24960.00vii 9.1.32 4 X 10 sq. mm (25mm) 20 Each 163.00 3260.00viii 9.1.1 2 X 6 sq. mm (19mm) 640 Each 125.00 80000.00

DSR Code No. Civil

LAYING OF PVC PIPES

17.0 2.10 Excatubg trenches of required width for pipes, cables, etc. including excation for sxoxkets, and dressing of sides, ramming of bottoms, depth upto 1.5 mtr, including getting out the excated soil, and then returning the soil ad required, in layers not exceeding 20cm in depth , inckuding consolidating each deposited layer by ramming, watering, etc. and disposing of surplus wxcabated soil ad directed, within a lead of 50 m.

2.10.1 All kinds of soili 2.10.1.1 Pipes, cables, etc not exceeding 80 mm dia 800 RM 118.00 94400.00ii 2.10.1.2 Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia 700 RM 192.75 134925.00iii 2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm 680 RM 300.90 204612.00

18.0 4.1 CABLE TRAYSSupplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc. as required.

i 4.1.1 100 mm width x 50 mm depth x 1.6 mm thickness 1000 Metre 459.00 459000.00ii 4.1.2 200 mm width x 50 mm depth x 1.6 mm thickness 800 Metre 523.00 418400.00iii 4.1.3 300 mm width x 50 mm depth x 1.6 mm thickness 50 Metre 640.00 32000.00

C LIGHT FIXTURES & LUMINAIRES

19.0 1.41 INSTALLATION OF LIGHT FIXTUREInstallation, testing and commissioning of pre-wired, fluorescent fitting / compactfluorescent fitting of all types, complete with all accessories and tube etc. directly onceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copperconductor, single core cable and earthing etc. as required.

818 Each 82.00 67076.00

20.0 1.5 INSTALLATION OF EXHAUST FANInstallation of exhaust fan in the existing opening, including making good the damage,connection, testing, commissioning etc. as required.

i 1.50.1 Upto 450 mm sweep 24 Each 189.00 4536.0021.0 1.51 INSTALLATION OF LOUVERS

Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.22 Each 81.00 1782.00

22.0 1.44 INSTALLATION OF CEILING FANInstallation, testing and commissioning of ceiling fan, including wiring the down rods ofstandard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor,single core cable etc. as required.

322 Each 87.00 28014.00

D HIGH MAST LIGHTINGDSR-2013 Civil

PROTECTION FOR 2 NOS. HIGH MASTS

23.0 10.2 Sructural steel work riveted, bolted or welded in built up sectios, trusses and framed work , including cutting, hoisting fixing in position and applying a proming coat of approved steel primer all complete.

588.80 Kg 73.65 43365.12

24.0 4.1 Providing and laying in position cement concrete of specified grade exculding the cost centering shutering.

i 4.1.3 1:2:4 (1 cement: 2 coares sand: 4 graded stone agregate 20 mm nominal size) 0.432 cum 4921.70 2126.1725.0 2.6 Earth work in excavation by mechanical means (Hydrolic excavation by mechanical

means over areas (Exceeding 30 cm in depth 1.5 m in width as well as 10 sq m on plan) including disposal of excavated earth, lead ud up to 50m and lift up to 1.5 m, disposed earh to be levelled and neatly dressed.

i 2.6.1 All kinds of soil. 0.432 cum 146.50 63.2926.0 13.50.3 Applying priming coat with ready mixed red oxide zinc chromite primer of approved

brand and manufacture on steel galvanised iron/steel works.38.40 sqm 24.95 958.08

27.0 13.61 Painting with sythetic enamelled paint of approved brand and manufacture to give an even shade.

i 13.61.1 Two or more coats on new work. 29.46 sqm 63.05 1857.45E EARTHING & ELECTRICAL SAFETY ITEMS

DSR-2013 Electrical

EARTHING

28.0 5.4 Earthing with GI earth plate 600 x 600 x 6 mm thick including accessories, andproviding masonary enclosure with cover plate having locking arrangement andwatering pipe of 2.7 mtrs long etc. with charcoal, and salt etc. as required.

15 Each 4367.00 65505.00

29.0 5.6 Earthing with copper earth plate 600 x 600 x 6 mm thick including accessories, andproviding masonary enclosure with cover plate having locking arrangement andwatering pipe of 2.7 mtrs long etc. with charcoal, and salt etc. as required.

4 Each 8939.00 35756.00

30.0 5.2 Earthing with G.I. earth pipw 4.5 metre long, 40 mm dia including accessories, andproviding masonry enclosure with comer plate having locking arrangement andwatering pipe etc. with charcoal/cole and salt as required.

65 Each 3753.00 243945.00

31.0 5.15 Providing & fixing 25 x 5 mm GI earth strip on surface or in recess for connections etc. 500 Metre 133.00 66500.00

32.0 5.16 Providing & fixing 6 SWG dia GI wire on suface or in recess for loop earthing asrequired.

3000 Metre 34.00 102000.00

33.0 5.17 Providing & fixing 4mm dia copper wire on suface or in recess for loop earthing asrequired.

150 Metre 94.00 14100.00

34.0 6.9 Providing and fixing G.I. tape 20 mm x 3 mm thick on parapet or surface of wall forlightning conductor complete as required.

6000 Metre 32.00 192000.00

35.0 6.12 Providiing and fixing testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 mm long,with 4 Nos. of tinned G.I. bolts, nuts, chuck nuts and spring washers etc. Complete asrequired.

65 Each 69.00 4485.00

SAFETY EQUIPMENT36.0 2.21 Providing and fixing M.V. danger notice plate of 200mmx150mm made of mild steel,

atleast 2mm thick and vitreous enamelled white on both sides and with inscriptionsingle red colour on front side as required

10 Each 121.00 1210.00

TOTAL OF DSR-2013 Items 6662354.12Market Rate Electrical Items

A LT PANELS

37.0 MR Design, manufacturing, supply, erection, testing & commissioning of cubicle typepanels fabricated out of 2 mm CRCA sheet steel bolted and modular constructioncomplete with incoming/outgoing feeders, bus bars of electrolytic grade aluminiumduly insulated with heat shrinkable colour coded PVC sleeves and support onDMC/SMC supporters. Panel shall be totally enclosed dust and vermin proofconstruction with heavy duty neoprene gaskets. The floor/wall mounting panels shallbe provided with mounting channels/hooks respectively. The construction of panelsshall confirm to IS 8623:93. Panels shall incorporate double copper earthing bus, cablealleys, bus bar chambers, bus interconnections. The panel shall be baked enamel RAL-7032 siemens grey (Powder coated having a minimum thickness of 60 micron) painted.The panel shall be provided with name plate, designation plate for all incomingoutgoing feeders, danger plate. Mechanical/Electrical interlocking where ever requiredshall be incorporated considering propers operational safety of the personal &equipment. Panel shall be suitable for 50 KA short-circuit rating and Degree ofprotection shall be IP-42 for indoor and IP-54 for out door. Any item not specifically

37.01 MR MAIN LT PANEL- INDOOR TYPE 1 EachA INCOMERi 800A 4P ACB, EDO Type with Microprocessore based Thermal Magnetic Release 50KA -

01 No.ii Phase Indicators R-Y-B with 2A SP MCB, 10KA 3Nos. -01 Setiii Digital Multifunction Meter -01 Nosiv CT 800/5A -04 Nosv ON, OFF, TRIP & Fault IndicationB BUS-BARi 800Amp, TPN Aluminium Bus bar -01 SetC OUT GOINGSi 400Amp. TP MCCB, 50KA with rotary handle -01 Noii 200Amp. TP MCCB, 25KA with rotary handle -01 Noiii 160Amp. TP MCCB, 25KA with rotary handle -06 Nosiv 100Amp. TP MCCB, 25KA with rotary handle -02 Nosv 63Amp. TP MCB, 16KA -07 NosD CAPACITOR BANK FOR P.F. CORRECTION WITHIN MAIN LT PANELi 25kVAr, 480V -05 Nosii 15kVAr, 480V -01 Nosiii 10kVAr, 480V -01 Nosiv 5KVAr, 480V -02 Nosv APFC Relay 10 Point -01 Nosvi Capacitor Duty Contactors 25kVAr -05 Nos

vii Capacitor Duty Contactors 10kVAr -01 Nosviii Capacitor Duty Contactors 5kVAr -02 Nosix ON/OFF Indicators Red & Green -16 Setx ON/OFF Push Button Red & Green -16 Setxi Auto/Manual Selector Switch -08 Nosxii CT 400/5A cast resin type -03 Nosxiii Phase Indicators R-Y-B with 2A SP MCB, 10kA 3 Nos. - 01 Setxiv Digital Multifunction Meter -01 Nosxv 63A TP MCB 10kA -02 Nosxvi 40A TP MCB 10kA -02 Nos

37.02 MR TYPE -A BUILDING (LIGHT & POWER PANEL) OUT DOOR TYPE 1 EachA INCOMERi 200 Amp. TP MCCB, 25KA -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10KA 3 Nos - 01 Setiii Digital Multifunction Meter -01 Nosiv CT 200/5A -03 NosB BUS-BAR i 200A TPN Aluminium Bus bar -1 SetC OUTGOINGSi 63A, TP, MCB, 16KA -06 Nosii 40A, TP, MCB, 16KA -03 Nosiii 40A, DP, MCB, 16KA -05 Nosiv 3 Phase 4 wire KWh meter counter type 10-60A (L&T make or approved equivalent)

5A -02 Nosv 1 Phase KWh meter with LCD display10-60A (L&T make or approved equivalent) 5A -05

Nos37.03 MR TYPE -B BUILDING (LIGHT & POWER PANEL) OUT DOOR TYPE 1 Each

A INCOMERi 160Amp. TP MCCB, 25KA -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10KA 3 Nos -02 Setiii Digital Multifunction Meter -01 Nosiv CT 150/5A -03 NosB BUS-BAR i 160A TPN Aluminium Bus bar -1 SetC OUT GOINGSi 63A, TP, MCB, 16KA -05 Nosii 40A, TP, MCB, 16KA -05 Nosiii 40A, DP, MCB, 16KA -04 Nos

37.04 MR TYPE -C BUILDING (LIGHT & POWER PANEL) OUT DOOR TYPE 1 EachA INCOMERi 160Amp. TP MCCB, 25KA -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10kA 3 Nos -02 Setiii Digital Multifunction Meter -01 Nosiv CT 150/5A -03 NosB BUS-BAR i 160A TPN Aluminium Bus bar -1 SetC OUT GOINGSi 63A, TP, MCB, 16KA -05 Nosii 40A, TP, MCB, 16KA -03 Nosiii 40A, DP, MCB, 16KA -06 Nosiv 3 Phase Flush Mounting KWh meter (L&T make or approved equivalent) 5A- 02 Nos

v 1 Phase KWh meter with LCD display10-60A (L&T make or approved equivalent) 5A -06Nos

37.05 MR TYPE -D BUILDING (LIGHT & POWER PANEL) OUT DOOR TYPE 1 EachA INCOMERi 160Amp. TP MCCB, 25KA -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10KA 3Nos - 01 Setiii Digital Multifunction Meter -01 Nosiv CT 150/5A -03 NosB BUS-BAR i 160A TPN Aluminium Bus Bar -1 SetC OUTGOINGSi 63A, TP, MCB, 16KA -08 Nosii 40A, TP, MCB, 16KA -02 Nos

37.06 MR COMMON AREA (LIGHT & POWER PANEL) OUT DOOR TYPE 1 EachA INCOMERi 160Amp. TP MCCB, 25KA -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10KA 3Nos -02 Setiii Digital Multifunction Meter -01 Nosiv CT 150/5A -03 NosB BUS-BAR i 160A TPN Aluminium Bus Bar -1 SetC OUT GOINGSi 63A, TP, MCB, 16KA -03 Nosii 40A, TP, MCB, 16KA -02 Nos

iii 40A, DP, MCB, 16KA -04 Nosiv 1 Phase KWh meter with LCD display10-60A (L&T make or approved equivalent) 5A -03

Nos37.07 MR STREET LIGHT PANEL- OUT DOOR TYPE 1 Each

i 63Amp. TP MCB, 16KA as incomer -01 Nosii Phase Indicators R-Y-B with 2A SP MCB, 10kA 3Nos -01 Setiii Astronomiccal Time Switch 110-240VAC 3 Phase-4W 3 Channel (L&T make or

approved equivalent) -01 Nosiv Time Switch Quartz Daily 240V AC Flush Mountings (L&T make or approved

equivalent) -02 Nosv 100A TPN Aluminium Bus Bar -1 Setvi 40A TP MCB 16KA as outgoings -04 Nosvii 70A TP Power Contactor- 02 Nosviii Auto/Manual Selector Switch -01 Nosix ON/OFF Indicators Red & Green -04 Setx ON/OFF Push Button Red & Green -04 Set

B LT CABLES38.0 MR SUPPLY OF CABLES

Supply of LT XLPE insulated and PVC sheathed aluminium/copper conductor armouredpower cable 1100 volts grade conforming to IS:7098 (Part-I) of following sizes:

38.01 MR 3.5C x 400 sq mm A2XFY XLPE cable 200 RM38.02 MR 3.5C x 120 sq mm A2XFY XLPE cable 300 RM38.03 MR 3.5C x 95 sq mm A2XFY XLPE cable 450 RM38.04 MR 3.5C x 70 sq mm A2XFY XLPE cable 320 RM38.05 MR 4C x 25 sq mm A2XFY XLPE cable 1000 RM38.06 MR 4C x 16 sq. mm A2XFY XLPE cable 1400 RM38.07 MR 3C x 2.5 sq.mm Cu armoured YWY cable 7000 RM38.08 MR 2C x 4.0 sq.mm Cu armoured YWY cable 800 RM38.09 MR 2C x 6.0 sq.mm Cu armoured YWY cable 3000 RM38.10 MR 4C x 6.0 sq.mm Cu armoured YWY cable 1400 RM38.11 MR 4C x 10 sq. mm Cu Armoured YWY cable 1200 RM

SUPPLY PVC PIPES39.0 MR Supply of 6Kg/cm², PVC pipes (Pipes as per IS: 4985:2000) INCLUDING

LOADING/UNLOADING AND STORING ETC. Complete in all respect as required bty the Engineer-in-charge.

39.01 MR 50mm Outer Diameter PVC Pipes 800 RM39.02 MR 110mm Outer Diameter PVC Pipes 700 RM

39.03 MR 160mm Outer Diameter PVC Pipes 680 RMMANHOLE

40.0 MR Constructing masonry Inspectino Chamber in brick work with common burnt clay FPS (non-modular) bricks of class designation 7.5 in cement mortar 1:4 (1 cement :4 coarse sand) with precast reinforced cement concrete cover 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick, complete as per standard design :

40.01 MR Size 300mm x 300mm x 450mm deep inside 25 Each40.02 MR Size 600mm x 600mm x 600mm deep inside 70 Each

40.03 MR Size 1200mm x 600mm x1200mm deep inside 20 Each

C LIGHT FIXTURES & LUMINAIRESSUPPLY, ERECTION, TESTING & COMMISSIONING OF LIGHT FIXTURES

41.0 MR Supply of pre-wired, fluorescent fitting / compact fluorecent fitting/ LED decorative ordown lighter/ Bollard fixture of all types can be wall mounted fittings/ ceilingmounted/ floor mounted/ false ceiling mounted with all accessories including tube rod,CFL Lamp, LED Driver of suitable ratings etc., Complete in all respect, as required.

42.0 MR SHED LIGHTLED Canopy mediumbay luminaire system consuming 80W or less with lumen output5700-6000 or higher, colour temperature 6500, THD <20% & pf>0.95, surgeprotectionof 1.5KV, operating voltage 150v-280v, AC, 50Hz, Epoxy powder coated die-cast aluminium housing with weather proof gasketand control gear accessories etc.Complete in all respect.

195 Each

43.0 MR DOWN LIGHTERRecess mounted down lighter with satin finsh reflector suitable for 1x18W CFL Lampwith electronic ballast having THD <10% & pf >0.98 . Complete in all respect.

272 Each

44.0 MR 2'X2' RECESS CFL2' x 2' Recess mounted direct /indirect luminaire with flat translucent acrylic diffusersuitable for 2 x 36W CFL lamp configuration with shaped refelector cum housing inwhite powder coated steel delivers uniform luminance in vertical and horizontaldirection having electronic ballast with THD <10% & pf >0.98, Complete in all respect.

79 Each

45.0 MR BATTEN LEDHigh efficiency LED Linear lamp with extruded Al housing complete poly carbonatediffuser having system power consumption of 18W or less, lumen output 1600 lumensor higher, Color temperature 5700-6000K, THD <25% & pf >0.9, View angle should notbe less than 120 degree including surge protection of 1.5KV, operating voltage range150-280V, Ac, 50Hz, Complete in all respect.

91 Each

46.0 MR BOX TYPESlim energy saving BOX type fitting with 2 x 28W FTL made of white polyester precoated sheet steel housing & cover, Engineering plastic end caps and snap fit polycarbonate lamp holder suitable for electronic ballast with THD <10% and pf >0.98,Complete in all respect.

68 Each

47.0 MR FLEXIBLE STRIPHigh performance LED flexible strip light suitable for out door purpose with IP-65protection with power consumption of 14.4W/Mtr or less, lumen output 120lumens/W or higher, Color temperature 5700-6000K, view angle 120degree, THD <10%& pf >0.95, including surge protection of 1.5KV, operating voltage range 150-280V, Ac,50Hz, Complete with LED driver and in all respect. (Supply in 5Mtr Spool)

50 Nos

48.0 MR ADJUSTABLE DOWN LIGHTERAdjustable LED Circular down lighter with diffuser recess mounted having systempower consumption of 15W or less, lumen output 850lms or higher, Color temperature5700-6000K, THD <10% & pf >0.95, including surge protection of 1.5KV, operatingvoltage range 150-280V, Ac, 50Hz, complete in all respect.

24 Each

49.0 MR BOLLARD LIGHTLED bollard light Bajaj model no. BGBOM 450 or approved equivalent, consumingsystem power 6W or less, lumen output 240 lumens or higher, color temprature 4000,THD <30%, & pf >0.95, surge protection 1.5KV, operating voltage 150v-280volts AC,50Hz, complete in all respect.

20 Each

50.0 MR AVIATION LIGHTBajaj Model LED Aviation light luminaires BGAV 302 LED or approved equivalent.

2 Each

51.0 MR FACAD LIGHT1 x 250W Metal Halide Flood Light Fixture with lamp in aluminium die cast housing, toughned glass, gear box etc. Complete in all respect.

8 Each

52.0 MR FACAD LIGHT1 x 150W Metal Halide Flood Light Fixture with lamp in aluminium die cast housing, toughned glass, gear box etc. Complete in all respect.

8 Each

53.0 MR 300 mm Sweep Exhaust fan 900 rpm heavy duty CGL EXHD-6-1 with AluminiumLouvers (Cafeteria Kitchen & wash Rooms) or approved equivalent make.

24 Each

54.0 MR 250 mm Sweep Brisk Air Exhaust Fan CGL (Officers wash room) or approvedequivalent make.

2 Each

55.0 MR 1200 mm Sweep Ceiling Fan CGL White Model High Breeze Plus (Office Area) orapproved equivalent make.

153 Each

56.0 MR 1400 mm Sweep Ceiling Fan CGL White Model High Breeze Plus (Bays) or approvedequivalent make.

140 Each

57.0 MR 600 mm Sweep, 3 Phase, 200 W, 1400 rpm wall mounted CGL/Almonard (Bays) orapproved equivalent make.

32 Each

58.0 MR SINAGESSupply of Black Painted Extruded aluminium housing mounted with green/red LED,240V, 3W/LED (total wattage-8W) shall be Laser engraved Sinage, matter in threelanguage with errow mark (where ever required) on Double Acrylic sheet fixed on oneside. The sinage shall be provided with Ni-Cd Battery back up for minimum 2 hourswith battery charging facilty including suitable pendent mounting arrangement. Thesize of sinage shall not be less than 335L X 45W X 225H mm. The writing matter shallbe taken from the Engineer-in-charge. Complete in all respect as required.

28 Each

D STREET LIGHT59.0 MR GALVANIZED STEEL OCTAGONAL POLES

Supply,erection, testing & commissioning of galvanized steel octagonal pole of suitable length conforming to IS 2629/ IS 2633/ IS 4759. The pole shall be single piece (single hot dip galvaniaed) and shall tapered towards the top. The botttom section shall have openable slot with exterior surface door & shall have suitable locking attangement for housing three phase 4 wire cable connection, bakelite sheet, MCB, loop in and out arrangement for incoming/ outgoing cables. There shall also be suitable arrangement for the purpose of earthing. Rigid Base plate of suitable size and thickness shall be welded inside and outside at the botttom of pole with provision for fixing 4 foundatioin bolts. The octagonal pole shall be bolted on a precast foundation bolts for greater rigidity.

59.01 MR STREET LIGHT POLEGalvanized octagoal pole overall length 8 metre (sheet thickness 3mm), top dia. (A/F) 70mm and bottom dia. (A/F) 130mm, foundation size below ground level 550mm x 550mm x 1500mm, 4 Nos. foundation bolts size 16mm dia. Length ≥ 450mm with base plate diamensions 240mm x 240mm x 12mm thick.

36 Each

60.0 MR GALVANIZED OCTAGONAL POLE BRACKETS

60.01 MR SINGLE ARM BRACKETSupply and erection of single arm bracket 1.5 metre long for 4 to 6 metre long galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm (A/F) complete in all respect as approved by the Engineer-in-charge.

28 Each

60.02 MR DOUBLE ARM BRACKETSupply and erection of double arm bracket 1.5 metre long for 7 to 8 metre long galvanized octagonal pole, the bracket should be fixed on the top of the pole having top outer dia. 70mm (A/F) complete in all respect as approved by the Engineer-in-charge.

8 Each

E HIGH MAST LIGHTING61.0 MR Design, Supply, installation, testing and commissioning of heavy duty 30 M (Polygonal

GI), 3 sections High Mast with lantern carriage, suitable for 18 nos. flood light fittings,steel wire rope, gear box, control panel, flexible copper multi core copper cable of 4.0sqmm size etc. all as per specification including luminaires adjusting arrangement,proper aiming and providing and installation lighting arrestor and 1 no. double domeaviation obstruction light fittings with LED lamp as required including integral powertool for automatic raising and lowering of lantern carriage, electrical connections frombottom (control panel) to top shall be made by special trailing cable minimum 2 nos. 5core 4 sq.mm. copper. The system shall have inbuilt facilities for testing the luminaireswhile in lower position. Mast shalll be fitted with lightning finial. Erection andcommissioning of above equipments will be with the help of modern engineeringpractice including integral 3 phase/single phase non reversible power toperationalsafety of the personal & equipment. Panel shall be suitable for 50 KA short-circuitrating and Degree of protection shall be IP-42 for indoor and IP-54 for out door. Anyitem not specifically mentioned/specified in the BOM / shown in the SLD

2 Set

62.0 MR Design casting of open raft type shallow RCC foundation suitable for safe soil bearingcapacity of 10t/sq.mt. at 2 mtr depth, supply & fixing of foundation boltsmanufactured from special steel along with nuts, washer of suitable size of anchorplate and template etc. as per high mast manufacturer approved drawing is to besubmitted by the contractor before erection of foundation for approval.

2 Nos.

Supplying, installation, testing and commissioning of following luminaires completewith control gear and SONT/Metal halide lamp etc. including wiring from control gearto lamp with suitable size of PVC insulated cable as required.

63.0 MR

Flood light Cat No. RVP 301/2X400W (Philips Cat: RVP302 2xSONT 400W)/ BGENF 22R(Philips/Bajaj/CG)

72 Nos

64.0 MR Supplying, installation, testing and commissioning of control panel housing timercontactor, MCB circuit etc. for 18 nos. luminaires as per specification given belowfabricated out of 14 SWG sheet steel outdoor installation with canopy double door etc.as required.

64.01 MR 2 nos. 63 amps TPN MCB as incomer with phase indication.64.02 MR 2 nos. TP 32 amps 10 KA MCB , 2 nos. contactor L&T make, 2 nos. on/off indication

circuit, 2 nos. start/stop button, 2 nos. auto manual selector switch, 2 nos. controlMCB, Auxiliary contactor and photo cell 2 nos. timer relay.

64.03 MR Contol for power tool of high mast 25 amps TP MCB 10KA, 25 amps TP Contactor L&Tmake with 2 NO+2 NC auxilury contactor, overload relay with single phase preventorprotection, On/Off indication circuit 2 No.& 2 No. forward/reverse switch 1 no. etc. asrequired.

F EARTHING AND ELECTRICAL SAFETY ITEMS65.0 MR Supply and fixing of following safety equipment at suitable place in bus terminal as

required:-65.01 MR Fire buckets with stand (set of two buckets). 10 Each65.02 MR First Aid Box as approved by Indian red cross conforming to IS:2217. 2 Each65.03 MR Shock treatment chart in English & Hindi with frame. 2 Each65.04 MR Rubber mat 1000 mm wide x 12 mm thick checkered rubber mating of tested quality to

withstand 15 KV dielectric strength as per IS:5424.5 RM

65.05 MR 11 kV grade shock proof rubber hand gloves as per IS:4770. 2 Each65.06 MR Fire extinguisher 5 Kg CO2 type as per relevant IS specification. 2 Each

G CCTV, PA, ACCESS CONTROL & BOOM BARRIER SYSTEMA) CCTV System

66.0 MR Speed Dome Camera :- Supply, Installation, Testing & Commissioning of 6" SpeedDome, TDN, WDR, Optical 36x, Digital 12x, 540TVL, 1/4" Ex-view CCD, 0.01 lx (TDN,DSS), 128 preset (Max. 360¡ã/sec), 6 tour, 3 patterns, Multi-protocol, AC24V, PAL

6 Nos.

67.0 MR Bullet Camera :- Supply, Installation, Testing & Commissioning of 1/3" Sony CCD, Color,600TVL, IR Outdoor Vari-focal Bullet camera, 0Lux (IR LED On), Day/Night, 2.8-10mmVari-focal lens, IR Beam Distance 25-30m, IP66, Wall & Ceiling Mount, DC12V,PAL/NTSC

8 Nos.

68.0 MR Box Camera:- Supply, Installation, Testing & Commissioning of 1/3" inch 600TVL linescolor True Day/Night fixed C/CS mount varifocal, 5-50 mm, autoiris lens camera withBMB, WDR, Privacy Masking, PIP features complete with power supply, IP 66 Housingand brackets as required.

35 Nos.

Set2

69.0 MR IR Dome Camera:- Supply, Installation, Testing & Commissioning of 1/3" inch CCDColor Vandal Proof indoor IR dome camera with 2.8-10mm fixed Lens, 600TV Linesresolution, BMB, WDR, Privacy Masking, PIP features complete with power supply.

6 Nos.

70.0 MR PTZ Controller:- Supply, Installation, Testing & Commissioing of Netwrok KeypadJoystick controller with LCD Display

1 Nos.

71.0 MR Digital Video Recorder(DVR): Supply, Installation, Testing & Commissioing of 16channel Real time, 400 fps digital video recorder with D1 recording on all channels,capable for one month recording, should support 16Tb Internal HDD with 8SATA Port,with 2 TB HDD storage.

4 Nos.

72.0 MR Supply, Installation, Testing & Commissioing of 40" Full HD LED Display 4 Nos.73.0 MR Supply, Installation, Testing & Commissioing of SMPS for each camera with switch

socket1 Lot

74.0 MR Supply and fixing of 50 mm dia MS Pole powder coated ,10 meter long along withfoundation and cable entry juction box etc. For speed dome camera

6 Nos.

75.0 MR Supplying water proof junction box made of thermo plastic (IP65) size 200 mm x 160mm x 98 mm internally embedded gasket, rust proof, shook proof, with terminals forconnecting incoming & outgoing cables, neutral link with provision of 6 Amp. switch &Socket, pole mounting clamp of size and IP65 glands for cable entry. (For PTZCameras& outdoor Cameras)

55 Nos.

76.0 MR Supply , Installation , Laying of 25 mm ISI marked M.S. Conduit with Fittings,Accessories like saddle etc as required.

2000 Mtr.

77.0 MR Supply and laying of the Armoured RG-11 signal cable 7000 Mtr.78.0 MR Supply and drawing of the 2 x 1.5 sq. mm PVC insulated copper conductor armoured

cable for camera power including cable glands.5000 Mtr.

79.0 MR Supply & installation of CAT-6 cxable for PTZ Camera 2000 Mtr.80.0 MR Supply & Fixing of Rack for CCTV Accessories 1 Lot

Access Control System81.0 MR Supply, installation, testing & Commissioning of standalone Access Door controller

capable of controlling 1 Nos. doors along with individual access door controllers/Reader modules, required interface module for connecting to existing PC for Accesscontrol systems, Time attandence software module, power supply unit with SMFbatteries etc. complete as per specifications and as required. The system shall becapable of managing upto 5000card holders database

3 Nos.

82.0 MR Supply, Installation , Testing and Commissioning of Access Control Managementsoftwar.

1 Nos.

83.0 MR Supply, Installation , testing and commissioning of PC with DVD Drive and 1 TB HDD,17" LCD Monitor and required Keyboard, Adapter for Ethernet networking ,compatiblewith TCP/IP network protocols with a minimum bandwidth of 100Mbps along withMicrosoft Windows software OS complete in all respects

1 Nos.

84.0 MR Supply, Installation , testing and commissioning of Standard Range Proximity Readersuitable for Internal environment applications with a Read range of 4 to 5 Cms

6 Nos.

85.0 MR Supply, Installation, testing and commissioning of double side printable ProximityAccess Card.

50 Nos.

86.0 MR Supply , Installation , Laying of 25 mm ISI marked M.S. Conduit with Fittings,Accessories like saddle etc as required.

300 Mtr.

87.0 MR Supply and drawing of the 2 x 1.5 sq. mm PVC insulated copper conductor armouredcable for camera power including cable glands.

300 Mtr.

88.0 MR Supply & installation of CAT-6 cable 300 Mtr.

Public Address System89.0 MR Wall Mount Speaker :- Supply, installation, testing & commissioning of 24 W wall

mount speaker with necessary accessories,suitable for in door applications.40 Nos.

90.0 MR Horn Speaker :- Supply, installation, testing & commissioning of 25 W horn speakerwith necessary accessories,suitable for out door applications.

20 Nos.

91.0 MR Booster/Power Amplifier :- Supply, installation, testing & commissioning of 480 wattbooster/power amplifer 100V, 8ohms output . Plena with LED lamps for supervisingpower supply,overheating & pilot tone status. It should have 19", 3U high housing fortable or Rack mounting.Generally, as per the following specifications:

4 Nos.

91.01 MR 2 Balanced Mic inputs through Combo (Female XLR socket cum 1/4" Stereo PhoneJack) connectors.Facility to receive local music source as well as a priorityannouncement from a remote system with automatic switching between the twofeeds.

91.02 MR Mic-1 and Telephone input provided with Voice Operated Priority over all otherprogrammes.

91.03 MR Preamplifier and Line Output for recording the programme and connecting to abooster amplifier.

91.04 MR Resettable circuit breaker for protection against overload and short circuit as well asoverheating.Temp. controlled fan to be provided.

91.05 MR Instant transfer to DC Power (Car Battery) if AC power fails.

92.0 MR Zone Station :- Supply, installation, testing & commissioning of Voice Alarm 6 ZoneCall station with zone selection keys, all call key, momentaory PTT-key for calls, LEDindications for zone selection/fault/emergency state with metal base, flexiblegooseneck microphone stem and a unidirectional condenser microphone for makingvoice announcements through PA system

1 Nos.

93.0 MR Voice Alarm System Controller for above System. 1 Nos.94.0 MR Supply and drawing of the 2 x 1.5 sq. mm PVC insulated copper conductor armoured

cable for camera power including cable glands.3000 Mtr.

95.0 MR Supply , Installation , Laying of 25 mm ISI marked M.S. Conduit with Fittings,Accessories like saddle etc as required for outdoor area.

1200 Mtr.

96.0 MR Supply & Fixing of Rack for above system. 1 Lot

Boom Barrier System97.0 MR Boom Barrier :- Supply, installation, testing & commissioning of Electrically Operated

Electromechanical Type Boom Barrier of 4 Meter in Length, 100% Duty Cycle Barrieronly , Opening/Closing time of 2.5-6 Secs , should have minimum IP Proetction Level ofIP 54, Should have inbuilt Safety at Impact feature and Rubber protection at Bottom ofBoom along with push button for operation, safety Sensor Photocells complete asrequired as per following specifications.

8 Nos.

97.01 MR The Boom Barrier Should be of Electromechanical type only .97.02 MR Power Supply : 230 V AC , 50 Hz97.03 MR The Duty cycle of Boom Barrier Should be 100% ( Continous Operation)97.04 MR The Boom length should be of upto 4 Meter with opening time 2.5-6 Secs (Adjustable)

97.05 MR The Motor Speed Shoould be 2450 RPM97.06 MR The Working Temperature should be -10 deg c to +60 deg c97.07 MR The Electronic Control Board Shall have electric limit switches for stopping and shall

have electronic magnetic reverser for safety on closing.97.08 MR The Barrier shall be manually opearted in case of power failure97.09 MR The Barrier Structure shall be of Fe 360m pickled plate 2.5 MM97.10 MR Dimensions of barrier strcuture shaould be 320 L x 280 P x 1.110 H mm97.11 MR Cataphoresis pre-treatment at 200° C + powder coati ng at 180°. Thermosetting

polyesther powder coating red RAL 3002 "rough surface"97.12 MR The Barrier structure shall have Minimum IP 54 Protection Level97.13 MR The Boom Material shall be of aluminimum 6060 with white and red reflective

adhesives and shall have inbuilt LED Light fitted in original from OEM.

98.0 MR Supply and drawing of the 2 x 1.5 sq. mm PVC insulated copper conductor armouredcable for camera power including cable glands.

1000 Mtr.

TOTAL OF MARKET RATE ITEMS