accepta water analysis equipment test reagents catalogue

119
www.accepta.com 1

Upload: farida-zulfah-fitriani

Post on 24-Sep-2015

43 views

Category:

Documents


13 download

DESCRIPTION

water analysis

TRANSCRIPT

  • www.accepta.com 1

  • www.accepta.com 2

    Table of Contents

    Section Details Page2.0 : General Information 2.1 - 2.4 Accepta Ltd. Details, Services & Ordering. 3

    3.0 : Test Method Selector 3.0 Test Parameter / Method Selector 4

    4.0 : Test Kits 4.1 Comprehensive Engineer Test Kit (Various versions)4.2 Cooling (Open & Closed) (Standard & Backpack versions)4.3 Closed Water Systems4.4 Chlorination4.5 Boiler Water4.6 Legionella Compliance4.7 Ion Exchange Resin Kit4.8 Manual Silt Density Index

    823272829313334

    5.0 : Pocket Test Meters 5.1 PH1 - pH/Temperature Meter5.2 EC1 - Condy/TDS/Temp/Salinity Meter5.3 PH100 - Extech pH/Temperature Meter5.4 EC400 - Extech Condy/TDS/Temp/Salinity Meter5.5 EC500 - Extech Combined pH/Condy/TDS/Temp Meter5.6 CL200 - Extech Total Chlorine/Temperature Meter5.7 DO600 - Extech Oxygen/Temperature Meter5.8 RE300 - Extech Redox (ORP) /Temperature Meter5.9 RefG300 - Glycol Refractometer

    363738394041424344

    6.0 : Professional Test Meters 6.1 Martini MI806 - 4 in 1 pH/Conductivity/TDS/Temp Meter6.2 Eutech pH 11 - pH Meter6.3 Eutech Con 11 - Conductivity Meter6.4 Eutech PC300 - Combined pH/ Condy/TDS/Temp Meter6.5 Jenway 350 - pH Meter6.6 Jenway 470 - Conductivity/TDS/Temp Meter6.7 Jenway 430 - Combined pH/ Conductivity/TDS/Temp Meter6.8 TRANSEC - Conductivity/TDS/Salinity/Temp Meter6.9 TRANSPH - pH/ORP Meter6.10 Borescope

    46474849505152535455

    7.0 : Drop Test Kits 7.1 Drop Test Kits - Acidity to Zinc 57

    8.0 : MiniKits 8.1 MiniKits - Acidity to Zinc 64

    9.0 : Comparator Kits 9.1 Comparators - Aluminium to Zinc 67

    10.0 : Titration Test System 10.1 Titration Cartridge Tests - Alkalinity to Zinc 74

    11.0 : Test Strips 11.1 Test Strips - Ammonia to Zinc with many pH ranges 77

    12.0 : Bacteria Testing 12.1 Oxidising Kits (Extech pen)12.2 Non Oxidising Kits (Isothiazolone etc)12.3 ATP Meter & Swabs12.4 Dipslides & NRB/SRB Tube Tests12.5 Incubators12.6 Universal Rapid Legionella Test Kit12.7 Dip-slide Comparator App

    80818283848586

    13.0 : Corrosion Coupons 13.1 Corrosion Coupons & Test Racks 88

    14.0 : PrimeLab Photometer 14.1 PrimeLab (Single or Multi Range) Photometer14.2 Parameters & Reagents

    9092

    15.0 : Temperature Meters 15.1 - 15.4 Temperature Meters 102

    16.0 : Equipment 16.1 Equipment & Components 107

    17.0 : Reagents 17.1 Reagents Available 110

  • www.accepta.com 3

    Section 2.0

    2.2 Laboratory & Support ServicesOur extensive laboratory is able to offer a wide range of services which include:

    Full system water analysis Deposit analysis. Corrosion coupon weighing. Determination of product factors for tests like Phosphonate, Nitrite, Molybdate etc. Calibration services on an extensive range of meters.

    2.3 Training Services

    With many years experience in the water treatment and testing market we are highly trained in advis-ing clients in the use and application of test kits and reagents.

    We offer specific training in the use of test kits and the various test options available.

    Training can be carried out at our offices/laboratory or can be offered on site and the training canbe tailored to suit your application and requirements and a wide range of subjects can be covered.

    2.4 Ordering & TermsOrders can be accepted by the following methods or via our on line portal.Email:Phone:Fax:

    General1) Prices, where quoted are exclusive of VAT and delivery.2) For Terms & Conditions of Sale, please refer to our website www.accepta.com/terms-conditions3) Orders received will generally be dispatched within 2 working days.4) A standard delivery charge will apply on all orders.5) The delivery charge for dip slides and/or large test kits and reagent orders will be dependant onthe weight of the goods, please ask for a quote for delivery charges.6) The shelf life of most reagents is greater than 2 years when stored in correct conditions. Pleaserefer to the relevant reagent Safety Data Sheet (SDS) for full details.7) All reagents and kits can be branded with your own logo, please contact us for details.8) Product SDS sheets are available own branded and in many languages, please ask for details.9) All electronic equipment is warranted for 12 months from date of dispatch.10) Probes for pH, Conductivity and other meters are warranted for 6 months from date of dispatch.11) Returns must be notified in writing within 48 hours of receipt of goods.12) All payments are due within 30 days from date of invoice.13) If an invoice remains unpaid after our agreed payment terms, we reserve the right to forward theinvoice to a debt collection agency which will incur an additional 20% surcharge.14) Some images of test kits and components shown in the catalogue may differ from the actualgoods supplied due to stock availability.

    2.1 Company Information

    AcceptaStatham HouseTalbot RoadManchester M32 0FPUnited Kingdom

    Tel : +44 (0) 161 977 2334Fax : +44 (0) 870 135 6389Email : [email protected]

    [email protected]+44 (0) 161 877 2334 (e-mail confirmation is required on all telephone orders)+44 (0) 870 135 6389

  • www.accepta.com 4

    Section 3.0Test Method SelectorThis useful selector can be used to help identify the test methods we have available for thoseparameters you wish to monitor. Simply select the parameter from the left column, then work acrossto identify which test methods are available. If you need help identifying the most appropriate testmethod for your application please contact Acceptas technical team.

    Parameter PrimeLab Drop Test TitrationTests

    Comparator Powder PillowEquivalents

    TestMeters

    Acidity

    Active Oxygen

    Alkalinity

    Aluminium

    Amine

    Ammonia

    Anionic

    Boron

    Bromine

    Carbohydrazide

    Chelant

    Chloride

    Chloramines

    Chlorine (TS)

    Chlorine Dioxide (TS)

    Chlorite

    Chromium

    COD (LR, MR & HR) Requires heater block

    Colour

    Conductivity/TDS

    Copper (TS)

    Cyanuric Acid

    DEHA

    DBNPA Biocide Kit

    Fluoride

    Glutaraldehyde Biocide Kit

    Glycol (PEG/MEG)

    Hardness, Calcium

    Hardness, Stop/Go

    Hardness, Total (TS)

  • www.accepta.com 5

    Parameter PrimeLab Drop Test TitrationTests

    Comparator Powder PillowEquivalents

    TestMeters

    Hydrazine

    Hydroquinone

    Hydrogen Peroxide(TS)

    Iodine

    Iron (TS)

    Isothiazalone Biocide Kit

    Magnesium

    Manganese (TS)

    Molybdate

    Nickel

    Nitrate

    Nitrite

    Ozone

    Peracetic Acid (TS)

    pH (TS)

    Phenol

    PHMB

    Phosphate

    Phosphonate

    Polyacrylate

    Polyamine

    Polymers

    Potassium (TS)

    QAC

    Silver

    SodiumHypochlorite

    Sulphate

    Sulphide

    Sulphite

    Suspended Solids

    Silica

    Tannin

    Section 3.0Test Method Selector (continued)

  • www.accepta.com 6

    Parameter PrimeLab Drop Test TitrationTests

    Comparator Powder PillowEquivalents

    TestMeters

    THPS Biocide Kit

    Total Oxidant

    Triazole

    Turbidity

    Zinc

    Note: Parameters above with a (TS) denotes where Test Strips are available as an alternative testingmethod.

    IF THE PARAMETER YOU ARE INTERESTED IN IS NOT LISTED, PLEASE CONTACT US

    Section 3.0Test Method Selector (continued)

  • www.accepta.com 7

    Section 4.0Test Kits

  • www.accepta.com 8

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P

    Acceptas Eng3005P comprehensive combined test kit is based onphotometer and titration gun chemistries and has been developedas a complete kit, specifically for water treatment professionalsinvolved with the maintenance and management of boiler, coolingwater and closed water systems.Water systems require careful test monitoring to ensure the correctrisk management regimes and water treatment programmes aremaintained at all times. Failure to maintain the correct watersystem conditions can lead to serious problems, including reducedsystem efficiency, the build-up of scale, potentially damagingcorrosive water conditions and increased microbiological activity,which may result in the proliferation of Legionella bacteria and theincreased risks associated with Legionnaires disease.

    Contents Range CodeAluminium Case complete with foam & white testing board Eq5026

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 5ml Standard Syringe Eq5077

    1 x 1ml Standard Syringe Eq5074

    1 x Filter Holder 25mm Eq5044

    1 x Filter Paper 25mm GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    1 x 125ml Plastic Test Bottle Eq5008

    4 x 65ml Plastic Test Bottle Eq5018

    1 x 5/10ml Tube Eq5015

    1 x 250ml Washer Bottle Eq5082

    Jenway 430 Combined pH/Conductivity/TDS & Temp Meter Eq5119

    PrimeLab Photometer Plp1001

    10ml Glass Cells for PrimeLab Photometer (6) Pla1100

    Alkalinity P (Titration) 0 - 2000

    PA1 (65ml) Dt1001

    Alkalinity cartridge (2 x 20ml for all Alkalinities) Crt91002

    Alkalinity M (Titration) 0 - 2000

    TA4 (65ml) Dt1004

    Alkalinity OH (Titration) 0 - 2000

    PA3 (65ml) Dt1007

    Our comprehensive combined test kit is presented in its own robust Aluminium case and includes allthe equipment and reagents necessary to effectively test and monitor boiler, cooling and closedsystem waters to ensure optimum operating conditions are achieved and maintained.

    This test kit includes the following:

  • www.accepta.com 9

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P (continued)

    Contents Range Code

    Bromine (PrimeLab) 0.05 - 18

    PL DPD 1 A (30ml) Plr1102

    PL DPD 1 B (30ml) Plr1103

    PL DPD Nitrite Powder (20g) Plr1104

    Chloride (Titration) 0 - 2000

    BC1/CC1 (65ml) Dt1023

    Chloride Cartridge (2 x 20ml) Crt91003

    Chlorine (PrimeLab) 0.01 - 8

    PL DPD 3 C (30ml) (also requires PL DPD 1 A & B) Plr1104

    Chlorine Dioxide (PrimeLab) 0.02 - 15

    PL DPD Glycine (30ml) (also requires PL DPD 1 A & B) Plr1106

    Hardness, Total (Titration) 0 - 2000

    TH2 (65ml) Dt1046

    TH5 (65ml) Dt1047

    Hardness Cartridge HR (2 x 20ml for all Hardness) Crt91007

    Hardness, Calcium (Titration) 0 - 2000

    CH2 (65ml) Dt1043

    CH1P (20g) Dt1050

    Hardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Iron Soluble & Total (PrimeLab) 0 - 30

    PL Iron HR 1 (65ml) Plr1119

    PL Iron HR 2 (30ml) Plr1120

    Molybdate HR (PrimeLab) 5 - 200 (with dilution 50 - 2000)

    PL Molybdate 1 (65ml) Plr1139

    Nitrite (PrimeLab) 0 - 3000

    PL Nitrite HR 2 (65ml) Dt1072

    Phosphate HR (PrimeLab) 0 - 100

    PL Phosphate HR 1 (65ml) Plr1145

    PL Phosphate HR 2 (65ml) Plr1146

    Phosphonate (PrimeLab) 0 - 20

    PL Phosphonate 1 (20g) Plr1169

    PL Phosphonate 2 (20g) Plr1170

    PL Phosphonate 3 (65ml) Plr1171

    PL Phosphonate 4 (20g) Plr1172

  • www.accepta.com 10

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P (continued)

    Contents Range CodeSulphite (PrimeLab) 5 - 50

    PL Sulphite HR 1 Tablets (50pk) Plr1203

    PL Sulphite HR 2 Tablets (50pk) Plr1204

    Tannin (PrimeLab) 0 - 300

    PL Tannin 1 (65ml) Plr1176

    PL Tannin 2 (30ml) Plr1177

    Calibration Solutions for Jenway 430 Meter

    Standard Conductivity 12.88mS (65ml) Dt1154

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Refractometer (PEG & MEG) 0 - 60% RefG300

    1 x Digital Titrator (For Titration complete with bracket) Eq5022

    6 x Titrator Accessory Pack Eq5023

  • www.accepta.com 11

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P/DT

    Contents Range CodeAluminium Case complete with foam & white testing board Eq5026

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 5ml Standard Syringe Eq5077

    1 x 1ml Standard Syringe Eq5074

    1 x Filter Holder 25mm Eq5044

    1 x Filter Paper 25mm GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    1 x 125ml Plastic Test Bottle Eq5008

    4 x 65ml Plastic Test Bottle Eq5018

    1 x 5/10ml Tube Eq5015

    1 x 250ml Washer Bottle Eq5082

    Jenway 430 Combined pH/Conductivity/TDS & Temp Meter Eq5119

    PrimeLab Photometer Plp1001

    10ml Glass Cells for PrimeLab Photometer (6) Pla1100

    Alkalinity P (Drop Test) 5 - 2400

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml) (also requires PA2/TA2 & TA3) Dt1004

    Alkalinity OH (Drop Test) 5 - 2400

    PA3 (65ml) (also requires PA1, PA2/TA2 & TA3) Dt1007

    Acceptas Eng3005P/DT comprehensive combined test kit isbased on photometer and drop test chemistries and has been de-veloped as a complete kit, specifically for water treatment profes-sionals involved with the maintenance and management of boil-er, cooling water and closed water systems.Water systems require careful test monitoring to ensure the correctrisk management regimes and water treatment programmes aremaintained at all times. Failure to maintain the correct watersystem conditions can lead to serious problems, including reducedsystem efficiency, the build-up of scale, potentially damagingcorrosive water conditions and increased microbiological activity,which may result in the proliferation of Legionella bacteria and theincreased risks associated with Legionnaires disease.

    Our comprehensive combined test kit is presented in its own robust Aluminium case and includes allthe equipment and reagents necessary to effectively test and monitor boiler, cooling and closedsystem waters to ensure optimum operating conditions are achieved and maintained.

    This test kit includes the following:

  • www.accepta.com 12

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P/DTContents Range Code

    Bromine (PrimeLab) 0.05 - 18

    PL DPD 1 A (30ml) Plr1102

    PL DPD 1 B (30ml) Plr1103

    PL DPD Nitrite Powder (20g) Plr1104

    Chloride (Drop Test) 0 - 3000

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    Chlorine (PrimeLab) 0.01 - 8

    PL DPD 3 C (30ml) (also requires PL DPD 1 A & B) Plr1104

    Chlorine Dioxide (PrimeLab) 0.02 - 15

    PL DPD Glycine (30ml) (also requires PL DPD 1 A & B) Plr1106

    Hardness, Total (Drop Test) 5 - 1200

    TH2 (65ml) Dt1046

    TH3 (65ml) Dt1044

    H/TH4/CH3 (65ml) Dt1049

    TH5 (65ml) Dt1047

    Hardness, Calcium (Drop Test) 5 - 1200

    CH2 (65ml) Dt1043

    CH1P (20g) (also require TH3 & H/TH4/CH3) Dt1050

    Hardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Iron Soluble & Total (PrimeLab) 0 - 30

    PL Iron HR 1 (65ml) Plr1119

    PL Iron HR 2 (30ml) Plr1120

    Molybdate HR (PrimeLab) 5 - 200 (with dilution 50 - 2000)

    PL Molybdate 1 (65ml) Plr1139

    Nitrite (PrimeLab) 0 - 3000

    PL Nitrite HR 2 (65ml) Dt1072

    Phosphate HR (PrimeLab) 0 - 100

    PL Phosphate HR 1 (65ml) Plr1145

    PL Phosphate HR 2 (65ml) Plr1146

    Phosphonate (PrimeLab) 0 - 20

    PL Phosphonate 1 (20g) Plr1169

    PL Phosphonate 2 (20g) Plr1170

    PL Phosphonate 3 (65ml) Plr1171

    PL Phosphonate 4 (20g) Plr1172

  • www.accepta.com 13

    Section 4.1Engineers Test Kit with PrimeLab - Eng3005P/DT

    Contents Range CodeSulphite (PrimeLab) 5 - 50

    PL Sulphite HR 1 Tablets (50pk) Plr1203

    PL Sulphite HR 2 Tablets (50pk) Plr1204

    Tannin (PrimeLab) 0 - 300

    PL Tannin 1 (65ml) Plr1176

    PL Tannin 2 (30ml) Plr1177

    Calibration Solutions for Jenway 430 Meter

    Standard Conductivity 12.88mS (65ml) Dt1154

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Refractometer (PEG & MEG) 0 - 60% RefG300

  • www.accepta.com 14

    Section 4.1Comprehensive Engineers Test Kit - Eng3005

    Contents Range CodeAluminium Case complete with foam & white testing board Eq5026

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 5ml Standard Syringe Eq5077

    1 x 1ml Standard Syringe Eq5074

    1 x Filter Holder 25mm Eq5044

    1 x Filter Paper 25mm GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    1 x 125ml Plastic Test Bottle Eq5008

    4 x 65ml Plastic Test Bottle Eq5018

    1 x Plastic Comparator Eq5085

    4 x 10ml Comparator Cells Eq5006

    1 x 5/10ml Tube Eq5015

    1 x 250ml Washer Bottle Eq5082

    Jenway 430 Combined pH/Conductivity/TDS & Temp Meter Eq5119

    Alkalinity P (Titration) 0 - 2000

    PA1 (65ml) Dt1001

    Alkalinity Cartridge (2 x 20ml for all Alkalinities) Crt91002

    Alkalinity M (Titration) 0 - 2000

    TA4 (65ml) Dt1004

    Alkalinity OH (Titration) 0 - 2000

    PA3 (65ml) (also requires PA1) Dt1007

    Acceptas Eng3005 comprehensive combined test kit is based ontitration gun & comparator chemistries and has been developed asa complete kit, specifically for water treatment professionalsinvolved with the maintenance and management of boiler, coolingwater and closed water systems.Water systems require careful test monitoring to ensure the correctrisk management regimes and water treatment programmes aremaintained at all times. Failure to maintain the correct watersystem conditions can lead to serious problems, including reducedsystem efficiency, the build-up of scale, potentially damagingcorrosive water conditions and increased microbiological activity,which may result in the proliferation of Legionella bacteria and theincreased risks associated with Legionnaires disease.

    Our comprehensive combined test kit is presented in its own ro-bust Aluminium case and includes all the equipment and reagents necessary to effectively test andmonitor boiler, cooling and closed system waters to ensure optimum operating conditions areachieved and maintained.

  • www.accepta.com 15

    Section 4.1Comprehensive Engineers Test Kit - Eng3005 (continued)

    Contents Range Code

    Bromine (Comparator) 0 - 5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Chloride (Titration) 0 - 2000

    BC1/CC1 (65ml) Dt1023

    Chloride Cartridge (2 x 20ml) Crt91003

    Chlorine (Comparator) 0 - 4

    DPD No3 Solution C (30ml) (also requires DPD 1 A & B) Dt1507

    Iron LR (Comparator) 0 - 1

    Fe5 (65ml) Dt1110

    Sulphuric Acid 50% (65ml) Dt1155

    Iron HR (Comparator) 0.5 - 10

    Fe10 (65ml) (also requires Sulphuric Acid 50%) Dt1247

    Hardness, Total (Titration) 0 - 2000

    TH2 (65ml) Dt1046

    TH5 (65ml) Dt1047

    Hardness Cartridge HR (2 x 20ml for all Hardness) Crt91007

    Hardness, Calcium (Titration) 0 - 2000

    CH2 (65ml) Dt1043

    CH1P (20g) Dt1050

    Hardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Molybdate VHR (Comparator) 0 - 500

    Molybdate HR (65ml) Dt1127

    Nitrite (Titration) 0 - 2000

    N1 (65ml) (also requires Sulphuric Acid 50%) Dt1072

    Nitrite Cartridge (2 x 20ml) Crt91009

    Phosphonate (Titration) 0 - 20

    P1/2 (65ml) Dt1514

    P3 (65ml) Dt1080

    P4L (65ml) Dt1291

    Phosphonate Cartridge (2 x 20ml) Crt91004

    Phosphate HR (Comparator) 0 - 80

    PB1 (65ml) Dt1111

    PB2 (65ml) Dt1112

  • www.accepta.com 16

    Section 4.1Comprehensive Engineers Test Kit - Eng3005 (continued)

    Contents Range Code

    Sulphite (Titration) 0 - 100

    S1 (40g) Dt1092

    Sulphite Cartridge (2 x 20ml) Crt91005

    Tannin (Drop Test) 0 - 300

    TN1 (40g) Dt1094

    TN2 (65ml) Dt1095

    Calibration Solutions for Jenway 430 Meter

    Standard Conductivity 12.88mS (65ml) Dt1154

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Refractometer (PEG & MEG) 0 - 60% RefG300

    1 x Digital Titrator (For Titration complete with bracket) Eq5022

    6 x Titrator Accessory Pack Eq5023

  • www.accepta.com 17

    Section 4.1Engineers Test Kit with Titration Syringe - Eng3005TS

    Contents Range CodeAluminium Case complete with foam & white testing board Eq5026

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 5ml Standard Syringe Eq5077

    1 x 1ml Standard Syringe Eq5074

    1 x Filter Holder 25mm Eq5044

    1 x Filter Paper GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    1 x 125ml Plastic Test Bottle Eq5008

    4 x 65ml Plastic Test Bottle Eq5018

    1 x Plastic Comparator Eq5085

    4 x 10ml Comparator Cells Eq5006

    1 x 5/10ml Tube Eq5015

    1 x 250ml Washer Bottle Eq5082

    Jenway 430 Combined pH/Conductivity/TDS & Temp Meter Eq5119

    Alkalinity P (Titration) 0 - 2000

    PA1 (65ml) Dt1001

    Alkalinity cartridge (2 x 20ml for all Alkalinities) Crt91002

    Alkalinity M (Titration) 0 - 2000

    TA4 (65ml) Dt1004

    Alkalinity OH (Titration) 0 - 2000

    PA3 (65ml) Dt1007

    Acceptas Eng3005TS comprehensive combined test kit is basedon titration syringe & comparator chemistries and has been de-veloped as a complete kit, specifically for water treatment profes-sionals involved with the maintenance and management of boiler,cooling water and closed water systems.Water systems require careful test monitoring to ensure the correctrisk management regimes and water treatment programmes aremaintained at all times. Failure to maintain the correct watersystem conditions can lead to serious problems, including reducedsystem efficiency, the build-up of scale, potentially damagingcorrosive water conditions and increased microbiological activity,which may result in the proliferation of Legionella bacteria and theincreased risks associated with Legionnaires disease.

    Our comprehensive combined test kit is presented in its own ro-bust Aluminium case and includes all the equipment and reagents necessary to effectively test andmonitor boiler, cooling and closed system waters to ensure optimum operating conditions areachieved and maintained.

    This test kit includes the following:

  • www.accepta.com 18

    Section 4.1Engineers Test Kit with Titration Syringe - Eng3005TS(continued)Contents Range Code

    Bromine (Comparator) 0 - 5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Chloride (Titration) 0 - 2000

    BC1/CC1 (65ml) Dt1023

    Chloride Cartridge (2 x 20ml) Crt91003

    Chlorine (Comparator) 0 - 4

    DPD No3 Solution C (30ml) (also requires DPD 1 A & B) Dt1507

    Hardness Total (Titration) 0 - 2000

    TH2 (65ml) Dt1046

    TH5 (65ml) Dt1047

    Hardness Cartridge HR (2 x 20ml for all Hardness) Crt91007

    Hardness Calcium (Titration) 0 - 2000

    CH2 (65ml) Dt1043

    CH1P (20g) Dt1050

    Hardness Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Iron Soluble & Total LR (Comparator) 0 - 1

    FE5 (65ml) Dt1110

    Sulphuric Acid 50% (65ml) Dt1155

    Molybdate VHR (Comparator) 0 - 500

    Molybdate HR (65ml) Dt1127

    Nitrite (Titration) 0 - 2000

    N1 (65ml) (also requires Sulphuric Acid 50%) Dt1072

    Nitrite Cartridge (2 x 20ml) Crt91009

    Phosphonate (Titration) 0 - 20

    P1/2 (65ml) Dt1514

    P3 (65ml) Dt1080

    P4L (65ml) Dt1291

    Phosphonate cartridge (2 x 20ml) Crt91004

    Phosphate HR (Comparator) 0 - 80

    PB1 (65ml) Dt11111

    PB2 (65ml) Dt1112

  • www.accepta.com 19

    Section 4.1Engineers Test Kit with Titration Syringe - Eng3005TS(continued)Contents Range CodeSulphite (Titration) 0 - 100

    S1 (40g) Dt1092

    Sulphite Cartridge (2 x 20ml) Crt91005

    Tannin (Drop test) 10 - 300

    TN1 (40g) Dt1094

    TN2 (65ml) Dt1095

    Calibration Solutions for Jenway 430 Meter

    Standard Conductivity 12.88mS (65ml) Dt1154

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Refractometer (PEG & MEG) 0 - 60% RefG300

    6 x Titrator Accessory Pack Eq5023

  • www.accepta.com 20

    Section 4.1Engineers Test Kit with Drop Tests - Eng3005DT

    Contents Range CodeAluminium Case complete with foam & white testing board Eq5026

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 5ml Standard Syringe Eq5077

    1 x 1ml Standard Syringe Eq5074

    1 x Filter Holder 25mm Eq5044

    1 x Filter Paper GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    1 x 125ml Plastic Test Bottle Eq5008

    4 x 65ml Plastic Test Bottle Eq5018

    1 x Plastic Comparator Eq5085

    4 x 10ml Comparator Cells Eq5006

    1 x 5/10ml Tube Eq5015

    1 x 250ml Washer Bottle Eq5082

    EC500 Combined pH/Conductivity/TDS/Temp/Salinity Meter EC500

    Alkalinity P (Drop Test) 5 - 2400

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml) (also requires PA2/TA2 & TA3) Dt1004

    Acceptas Eng3005DT comprehensive combined test kit is basedon photometer and titration gun chemistries and has been devel-oped as a complete kit, specifically for water treatment profession-als involved with the maintenance and management of boiler, cool-ing water and closed water systems.Water systems require careful test monitoring to ensure the correctrisk management regimes and water treatment programmes aremaintained at all times. Failure to maintain the correct watersystem conditions can lead to serious problems, including reducedsystem efficiency, the build-up of scale, potentially damagingcorrosive water conditions and increased microbiological activity,which may result in the proliferation of Legionella bacteria and theincreased risks associated with Legionnaires disease.

    Our comprehensive combined test kit is presented in its own robust Aluminium case and includes allthe equipment and reagents necessary to effectively test and monitor boiler, cooling and closedsystem waters to ensure optimum operating conditions are achieved and maintained.

    This test kit includes the following:

  • www.accepta.com 21

    Section 4.1Engineers Test Kit with Drop Tests - Eng3005DTContents Range Code

    Alkalinity OH (Drop Test) 5 - 2400

    PA3 (65ml) (also requires PA1, PA2/TA2 & TA3) Dt1006

    Bromine (Comparator) 0 - 5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Chloride (Drop Test) 0 - 3000

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    Chlorine (Comparator) 0 - 4

    DPD No3 Solution C (30ml) (also requires DPD 1 A & B) Dt1507

    Hardness, Total (Drop Test) 5 - 1200

    TH2 (65ml) Dt1046

    H/TH4/CH3 (65ml) Dt1049

    TH5 (65ml) Dt1047

    TH3 (65ml) Dt1044

    Hardness, Calcium (Drop Test) 5 - 1200

    CH2 (65ml) Dt1043

    CH1P (20g) (also requires H/TH4/CH3 & TH3) Dt1050

    Hardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Iron LR (Comparator) 0 - 1

    FE5 (65ml) Dt1110

    Sulphuric Acid 50% (65ml) Dt1155

    Iron HR (Comparator) 0.5 - 10

    FE10 (65ml) (also requires Sulphuric Acid 50%) Dt1247

    Molybdate VHR (Comparator) 0 - 500

    Molybdate HR (65ml) Dt1127

    Nitrite (Drop Test) 0-2000

    N1 (65ml) Dt1072

    N2 (65ml) Dt1073

    Phosphonate (Drop Test) 0 - 20

    P1/2 (65ml) Dt1514

    P3 (65ml) Dt1080

    P4L (65ml) Dt1291

    P5 (65ml) Dt1075

  • www.accepta.com 22

    Contents Range CodePhosphate (Comparator) 0-80

    PB1 (65ml) Dt1111

    PB2 (65ml) Dt1112

    Sulphite (Drop Test) 5 - 300

    S1 (40g) Dt1092

    S2 (65ml) Dt1093

    Tannin (Drop Test) 10-300

    TN1 (40g) Dt1094

    TN2 (65ml) Dt1095

    Calibration Solutions for Extech EC500 Meter

    Standard Conductivity 1413S (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Refractometer (PEG & MEG) 0-60% RefG300

    Section 4.1Engineers Test Kit with Drop Tests - Eng3005DT

  • www.accepta.com 23

    Section 4.2Cooling (Open & Closed) Water Test Kit - Cool3002

    Acceptas Cool3002 comprehensive Cooling (Open & Closed)Water Test Kit is based on drop test and colour comparatorchemistries and has been developed specifically for engineersand water treatment professionals involved with the mainte-nance and management of both open and closed cooling sys-tems to ensure optimum operating conditions.Cooling water systems require careful test monitoring to ensurethe correct water conditions are maintained at all times. Failureto maintain correct treatment programs can lead to seriousproblems including reduced efficiency, the build-up of scale,potentially damaging corrosive water conditions and increasedmicrobiological activity, which may include the growth ofLegionella bacteria. Replacements and components areavailable, please refer to replacement reagent section.

    Contents Range Code2019 Maxi Case with Foams Eq5027

    Waterproof instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x Filter Holder 25mm Eq5044

    1 x Filter Papers GF/C (50pk) Eq5048

    1 x Filter Paper 25mm 0.45 micron (50pk) Eq5061

    2 x 65ml Plastic Test Bottle Eq5018

    1 x Plastic Comparator Eq5085

    2 x 10ml Comparator Cells Eq5006

    1 x 5/10ml Tube Eq5015

    PH1 - pH/Temperature Meter 0 - 14 pH1

    EC1 - Conductivity/TDS/Temperature Meter 0 - 20.00 mS EC1

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml) Dt1004

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Bromine (Comparator) 0 - 5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Chloride (Drop Test) 0 - 3000

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    The Cooling (Open & Closed) Water test kit is presented in itsown robust case and includes all the equipment and reagents necessary to effectively test and moni-tor system waters.

  • www.accepta.com 24

    Section 4.2Cooling (Open & Closed) Test Kit - Cool3002 (continued)

    Contents Range CodeHardness, Calcium (Drop Test) 5 - 1200

    CH2 (65ml) Dt1043

    CH1P (20g) (also requires TH3 & H/TH4/CH3) Dt1050

    Hardness, Total (Drop Test) 5 - 1200

    TH2 (65ml) Dt1046

    H/TH4/CH3 (65ml) Dt1049

    TH5 (65ml) Dt1047

    TH3 (65ml) Dt1044

    Iron LR (Comparator) 0 - 1

    FE5 (65ml) Dt1110

    Sulphuric Acid 50% (65ml) Dt1155

    Iron HR (Comparator) 0 - 10

    FE10 (65ml) (also requires Sulphuric Acid 50%) Dt1247

    Molybdate VHR (Comparator) 0 - 500

    Molybdate HR (65ml) Dt1127

    Nitrite (Drop Test) 0 2000

    N1 (65ml) Dt1072

    N2 (65ml) Dt1073

    Phosphonate (Drop Test) 0 - 20

    P1/4L (65ml) Dt1514

    P5 (65ml) Dt1075

    Calibration Solutions for EC1 & pH1 Meter

    Standard Conductivity 1413S (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    Hardness, Stop/Go (Drop Test) 0-4

    Hardness Stop/Go Solution (65ml) Dt1129

  • www.accepta.com 25

    Section 4.2Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP

    Contents CodeWaterproof Back Pack Case with Foam Inserts Eq5026E

    Waterproof Instructions Eq5084

    1 x Plastic Comparator Eq5085

    2 x 10ml Comparator Cells Eq5006

    3 x Rigid Bottle 250ml Wide Neck Eq5064

    2 x 65ml Plastic Test Bottle Eq5018

    1 x Filter Holder 25mm Eq5044

    1 x Filter Papers GF/C (50pk) Eq5048

    1 x 10ml Luer Lock Syringe Eq5073

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 5/10ml Tube Eq5015

    PH1 - pH/Temperature Meter 0 - 14 pH1

    EC1 - Conductivity/TDS/Temperature Meter 0 - 20.00 mS EC1

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml Dt1004

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Hardness, Total (Drop Test) 5 - 1200

    TH2 (65ml) Dt1046

    H/TH4/CH3 (65ml) Dt1049

    TH3 (65ml) Dt1044

    TH5 (65ml) Dt1047

    The Cooling (Open & Closed) Backpack Test Kit is presented in its own robust case and harness andincludes all the equipment and reagents necessary to effectively test and monitor system waters.

    This test kit includes the following:

    Acceptas cooling (Open & Closed) Test Kit (Backpack Version)is designed for use on Cooling Towers and many types ofClosed Water Systems such as Chilled Water Circuits and Heat-ing systems.

    The Backpack Test Kit has most of the reagents andcomponents that are normally contained in a standard Open &Closed Test Kit but formatted into a backpack design for use bythe commuter in busy commercial areas.

    It includes all the equipment and reagents necessary to performthe below noted tests. Replacement reagents and componentsare available which make this kit a lasting addition to any watertreatment professional. Simple to use and fully portable.

  • www.accepta.com 26

    * For true Soluble and Total Iron determination, Sulphuric Acid 50% and 0.45 micron filter papersare required and can be ordered separately.

    Section 4.2Cooling (Open & Closed) Test Kit (Backpack) - Cool3002BP(continued)Contents Range: CodeHardness, Calcium (Drop Test) 5 - 1200

    CH2 (65ml) Dt1043

    CH1P (20g) (also requires TH3 & H/TH4/CH3) Dt1050

    Hardness, Stop/Go (Drop Test) 0-4

    Hardness Stop/Go Solution (65ml) Dt1129

    Chloride (Drop Test) 0-3000

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    Iron LR (Comparator) 0-1

    FE5 (65ml) See below note* Dt1110

    Iron HR (Comparator) 0.5 -10

    FE10 (65ml) See below note* Dt1247

    Bromine (Comparator) 0-5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Molybdate VHR (Comparator) 0-500

    Molybdate HR (65ml) Dt1127

    Nitrite (Drop Test) 0-2000

    N1 (65ml) Dt1072

    N2 (65ml) Dt1073

    Phosphonate (Drop Test) 0-20

    P1/4L (65ml) Dt1514

    P5 (65ml) Dt1075

    Calibration Solutions for EC1 & pH1 Meter

    Standard Conductivity 1413S (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

  • www.accepta.com 27

    Section 4.3Closed Water Systems Test Kit - Clo3003/Clo3003F

    Contents Range Code2011 Medium Case with Foams Eq5028/2

    Waterproof instructions Eq5084

    1 x 20ml Standard Syringe Eq5168

    1 x Plastic Comparator Eq5085

    2 x 10ml Comparator Cells Eq5006

    1 x 5/10ml Tube Eq5015

    PH1 - pH/Temperature Meter 0 - 14 pH1

    EC1 - Conductivity/TDS/Temperature Meter 0 - 20.00 mS EC1

    Iron HR (Comparator) 0.5 - 10

    FE10 (65ml) Dt1247

    Molybdate VHR (Comparator) 0 - 500

    Molybdate HR (65ml) Dt1127

    Nitrite (Drop Test) 0 - 2000

    N1 (65ml) Dt1072

    N2 (65ml) Dt1073

    Calibration Solutions for EC1 & pH1 Meter

    Conductivity Standard 1413s (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    This kit is presented in its own robust case and includes all the equipment and reagents necessary toeffectively test and monitor Closed Water System to ensure optimum operating conditions areachieved and maintained.

    This test kit includes the following:

    Please Note: CLK003F includes Filtration & Sulphuric Acid 50% for True Soluble and Total Iron.

    Acceptas comprehensive Closed Water System test kit is basedon colour comparator and drop test chemistries and has beendeveloped specifically for engineers and water treatmentprofessionals involved with the maintenance and managementof closed systems to ensure optimum operating conditions.

    Closed water systems require careful test monitoring to ensurethe correct water conditions are achieved during the course of atreatment programme.

    Failure to maintain the correct dosage levels can lead to scaling,corrosion and increased biological activity which can lead topotentially unstable water conditions.

    Liquid equivalent reagents are available on request.

  • www.accepta.com 28

    Section 4.4Chlorination Test Kit - Chlor3004

    Contents Range Code2004 Mini Case with Foams Eq5030

    Waterproof instructions Eq5084

    1 x Plastic Comparator Eq5085

    2 x 10ml Comparator Cells Eq5006

    1 x Tablet Crusher Eq5079

    PH1 - pH/Temperature Meter 0 - 14 pH1

    Chlorine LR (Comparator) 0 - 4

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    Chlorine HR (Comparator) 10 - 300

    Chlorine HR (65ml) Dt1179

    Acidifying Solution (65ml) Dt1180

    Calibration Solutions pH1 Meter

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    DPD No3 Solution C (30ml) Dt1507

    This kit includes all the reagents and equipment required to allow the monitoring of low rangechlorine (0 to 4ppm) and high range chlorine (0 to 300ppm). These are required to ensure the correctsystem conditions are achieved.

    This test kit includes the following:

    Acceptas chlorination test kit is based on colour comparatorchemistry and has been developed specifically for engineersand water treatment professionals involved with the chlorinationand disinfection of water systems.

    Water system chlorinations require careful test monitoring toensure the correct water conditions are achieved during thecourse of the disinfection procedure. Failure to achieve thecorrect dosage levels can lead to unsuccessful disinfections,whilst elevated levels can lead to potentially corrosive waterconditions.

    This kit is presented in its own robust case and includes all theequipment and reagents necessary to effectively test and mon-itor the chlorination procedure.

  • www.accepta.com 29

    Section 4.5Boiler Water Test Kit - Blr3001

    Contents Range Code2019 Maxi Case with Foams Eq5027

    Waterproof Instructions Eq5084

    1 x 20ml Luer Lock Syringe Eq5075

    1 x 10ml Luer Lock Syringe Eq5073

    1 x Filter Holder 25mm Eq5044

    1 x Filter Papers GF/C (50pk) Eq5048

    2 x 65ml Plastic Test Bottle Eq5018

    1 x Plastic Comparator Eq5085

    2 x 10ml Plastic Comparator Cells Eq5006

    PH1 - pH/Temperature Meter 0 - 14 pH1

    EC1 - Conductivity/TDS/Temperature Meter 0 - 20.00 mS EC1

    Alkalinity P (Drop Test) 5 - 2400

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml) (also uses PA2/TA2 & TA3) Dt1004

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    BC1/CC1 (65ml) Dt1023

    Chloride (Drop Test) 0 - 3000

    PA3 (65ml) (also uses PA1, PA2/TA2 & TA3) Dt1007

    Alkalinity OH (Drop Test) 5 - 2400

    1 x 5/10ml Tube Eq5015

    This professional Boiler Water Test kit is presented in its own robust case and includes all theequipment and reagents necessary to effectively test and monitor system waters to ensure optimumoperating conditions are achieved and maintained.

    This test kit includes the following:

    Acceptas comprehensive Boiler Water Test Kit is based on acolour comparator and drop test chemistries and has been de-veloped specifically for engineers and water treatment profes-sionals who are involved with the maintenance and manage-ment of boilers and boiler systems.

    Boiler Water and feed-water systems require careful testmonitoring to ensure the correct water conditions are maintainedat all times. Failure to maintain the correct water treatmentprograms can lead to serious problems including reduced boilerefficiency, scale, corrosive water conditions and reduced steampurity.

  • www.accepta.com 30

    Section 4.5Boiler Water Test Kit - Blr3001 (continued)

    Contents Range CodeHardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Hardness, Total LR (Drop Test) 5 - 120

    TH2 (65ml) Dt1046

    TH5 (65ml) Dt1047

    TH3 (65ml) Dt1043

    Phosphate (Comparator) 0 - 80

    PB1 (65ml) Dt1111

    PB2 (65ml) Dt1112

    Sulphite (Drop Test) 5 - 300

    S1 (40g) Dt1092

    S2 (65ml) Dt1093

    Calibration Solutions for EC1 & pH1 Meter

    Standard conductivity 1413S (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

    20% Acetic Acid (65ml) Dt1103

    Liquid equivalent reagents are available on request.

  • www.accepta.com 31

    Section 4.6Legionella Compliance Test Kit - Leg3006

    Contents Range Code

    2019 Maxi Case with Foams Eq5027

    Waterproof Instructions Eq5084

    1 x 20ml Standard Syringe Eq5168

    1 x 10ml Standard Syringe Eq5177

    2 x 65ml Plastic Test Bottle Eq5018

    1 x 5/10ml Tube Eq5015

    1 x Plastic Comparator Eq5085

    2 x 10ml Plastic Comparator Cells Eq5006

    PH1 - pH/Temperature Meter 0 - 14 pH1

    EC1 - Conductivity/TDS/Temperature Meter 0 - 20.00 mS EC1

    Alkalinity M (Drop Test) 5 - 2400

    TA4 (65ml) Dt1004

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Bromine (Comparator) 0 - 5

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Tablets (50pk) Dt1131

    Chloride (Drop Test) 0 - 3000

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1026

    CC2 (65ml) Dt1024

    Replacement reagents and other components are available, please refer to the relevant section.

    This test kit includes the following:

    Acceptas Legionella compliance kit is based on colour compar-ator and drop test chemistries and has been developed specifi-cally for engineers and water treatment professionals involved inthe weekly and monthly analysis of water systems.

    Cooling Water systems require careful test monitoring to ensurethe correct water conditions are achieved to reduce the risk ofLegionella. Failure to keep the system under control can lead toscale, corrosion and the growth of the potentially fatal Legionellabacteria.

    This kit is presented in its own robust case and includes all theequipment and reagents necessary to effectively monitor thewater conditions.

  • www.accepta.com 32

    Section 4.6Legionella Compliance Test Kit - Leg3006 (continued)

    Contents Range CodeHardness, Total (Drop Test) 5 - 1200

    TH2 (65ml) Dt1046

    TH5 (65ml) Dt1047

    TH3 (65ml) Dt1044

    H/TH4/CH3 (65ml) Dt1049

    Hardness, Calcium (Drop Test) 5 - 1200

    CH2 (65ml) Dt1043

    CH1P (20g) (also requires TH3 & H/TH4/CH3) Dt1050

    Hardness, Stop/Go (Drop Test) 0 - 4

    Hardness Stop/Go Solution (65ml) Dt1129

    Iron LR (Comparator) 0 - 1

    FE5 (65ml) Dt1110

    Calibration Solutions for EC1 & pH1 Meter

    Standard Conductivity 1413S (65ml) Dt1109

    pH 4 (65ml) Dt1119

    pH 7 (65ml) Dt1118

    pH 10 (65ml) Dt1161

  • www.accepta.com 33

    Section 4.7Resin Test Kit - Res3008

    Contents Range Code2004 Mini Case with Foam Eq5030

    Waterproof Instructions Eq5084

    1 x Optic Magnifier Eq5034

    1 x 65ml Plastic Test Bottle Eq5018

    1 x White Spoon, 0.5ml Eq5382

    1 x RA1 Iron Test Reagent (65ml) Dt1338

    1 x RA2 Iron test Reagent (65ml) Dt1336

    1 x RA3 Organic Test Reagent (65ml) Dt1339

    1 x De-ionised Water (65ml) Dt1210

    The Resin Test kit is presented in its own robust case and includes all the equipment and reagentsnecessary to effectively test and monitor the qualitative condition of ion exchange resins.

    This test kit includes the following:

    Ion exchange Resins should be checked when the plant isserviced to determine if the ion exchange resin is sufferingfrom fouling or damage which will reduce the plant efficiency.

    Acceptas portable and easy to use kit allows the qualitativeanalysis of ion exchange resins for the three main problemsencountered when water softeners or ion exchange plantefficiency is reduced.

    The ion exchange resin can be checked for Iron fouling,organic fouling and resin bead optical assessment. Failure tomaintain good quality resins will lead to serious problemsincluding reduced efficiency and the build-up of scale andincreased microbiological activity, which may include thegrowth of Legionella bacteria.

  • www.accepta.com 34

    Section 4.8Manual Silt Density Kit SDI001

    Contents Range CodeWaterproof Instructions Eq5084

    47mm Filter Holder Eq5086

    0.45m Micron Filter Papers (47mm) (50pk) Eq5181

    500ml Measuring Cylinder Eq5183

    Stopwatch/Clock Eq5239

    Dull Blunt Tweezers Dt1240

    SDI Assembly Dt1182

    These fine un-dissolved suspended particles tend to settle on the surface and in the process, foul themembrane. The net result is an increase in feed pressure, reduced flow and high conductivity ofpermeate. Spiral wound and hollow fine fibre membranes are the most vulnerable and once fouled,cleaning of the element is often difficult.

    Use of the KitSilt Density Index (SDI) is an empirical test developed for measuring the rate of fouling of nanofiltration (NF) or RO membranes.

    Suspended solids and colloidal materials in feed water are one of the biggest problems in reverseosmosis systems. Although most systems have some pre-treatment, including 5-micron pre-filters,these fine particles are responsible for the fouling of reverse osmosis membranes.

    In order to measure the degree of this fouling problem, a concept called Silt Density Index is used.Here, filtration rates are calculated by exposing a 0.45-micron filter to the feed water under pressure.

    An SDI of less than 5 is typically considered acceptable for reverse osmosis systems. This meansmembranes should foul at a very low rate at SDI values of less than 5. Although this concept worksmost of the time, there are exceptions when a lower SDI (less than 3) is desirable due to the natureof the suspended solids in feed water.

    Depleting supplies of fresh water, ground water contaminationand the rising cost of water have compelled industries toincreasingly turn to the desalination of brackish/sea water aswell as water recovered from treated industrial effluent andsecondary treated municipal sewage.

    All these recycled water systems use reverse osmosis (RO)system for removal of dissolved solids. The presence of finelydivided particles in feed water to an RO system can causeserious problems as they are too small to be retained byconventional pre-treatment systems and they find their way tothe RO membrane.

    The function of an RO membrane is to concentrate dissolvedsolids on one side of the membrane and allow water moleculesto permeate through the other side. Suspended, colloidalparticles are larger than dissolved solids and are rejected by themembrane.

  • www.accepta.com 35

    Section 5.0Pocket Test Meters

  • www.accepta.com 36

    Section 5.1PH1 - pH/Temperature Meter

    Acceptas waterproof pH1 Meter has a built in smart chip which offers manyadvanced functions and features for a stick style pH Meter.

    Features:

    Waterproof and rugged enough to withstand harsh environments.

    LCD display.

    Displays Max & Min values with data hold.

    Easy to replace pH electrode.

    Exchangeable with an ORP Probe for Redox.

    Auto recognition of buffer solutions.

    Automatic temperature compensation.

    Simultaneous display of pH and temperature.

    Auto shut off after 10 minutes.

    Icons on display for easy recognition of function.

    Specifications:

    pH:Temperature:Resolution:Accuracy:Power:Dimensions:Weight:

    Optional Extra:Redox Probe

    Replacement Probe:pH Probe

    0.00 to 14.00pH0 to 90C0.01 pH0.01pH, 1.8F/1C2 x CR2032 Button Batteries195 x 40 x 36mm150g

    Code:RE1P

    Code:pH1P

    Unique flat electrode which is very robust and isalmost unbreakable.

  • www.accepta.com 37

    Section 5.2EC1 - Conductivity/TDS/Temperature/Salinity Meter

    Acceptas waterproof EC1 Meter has a built in smart chip which offers manyadvanced functions and features for a stick style EC Meter.

    Features

    Unit is waterproof and rugged enough to withstand many harshenvironments.

    LCD Display.

    Displays Max & Min values with data hold.

    Easy to replace conductivity electrode.

    Auto recognition of conductivity solutions.

    Automatic temperature compensation.

    Simultaneous display of conductivity and temperature.

    Auto shut off after 10 minutes.

    Icons on display for easy recognition of function.

    Specifications

    Conductivity:

    TDS:

    Salinity

    Temperature:Power:

    Dimensions:

    Weight:

    Replacement Probe:EC/TDS Probe

    Ranges

    0 to 199.9S/cm200 to 1999S/cm2.00 to 19.99mS/cm0 to 99.9ppm (mg/L)100 to 999ppm (mg/L)1.00 to 9.99ppt (g/L)0 to 1000ppm100 to 999ppm (mg/L)1.00 to 12.00ppt0 to 90F2 x CR2032 Batteries

    36 x 173 x 41mm

    110g

    EC1P

    Max Resolution

    0.1S/cm1S/cm0.01mS/cm0.1ppm (mg/L)1ppm (mg/L)0.01ppt (g/L)

    1ppm (mg/L)

    0.1C

    Basic Accuracy

    2% FS

    2% FS

    1ppm / 0.01ppt

    0.2C

  • www.accepta.com 38

    Section 5.3PH100 - Extech pH/Temperature Meter

    The waterproof ExStik pH100 Meter has a built in smart chip which offersadvanced functions and features to a stick style pH Meter not found anywhereelse and has a robust flat surface electrode.

    Features: Flat surface pH electrode, rugged for harsh environments.

    Internal memory stores up to 15 labelled readings for easy recall.

    CAL feature, tells you when to recalibrate your meter.

    Analogue bar graph to conveniently view trends.

    Renew indicator tells you its time to replace your electrode.

    1, 2 or 3 point calibration automatically recognises buffer solutions.

    Automatic temperature compensation & waterproof to IP 57.

    Simultaneous display of pH and temperature & indicates reading stability.

    Data Hold, Auto Power Off and Low Battery Indication.

    Waterproof design floats in water.

    Interchangeable probes available for Chlorine & ORP

    Optional weighted base (EX006) holds plastic cup and ExStik Meter.

    Complete with flat surface pH electrode, protective sensor cap, samplecup with four 3V CR-2032 button batteries, and 1.2m neck strap.

    Specifications:

    pH:Temperature:Resolution:Accuracy:Power:Dimensions:Weight:

    Optional Extra:

    Weighted Base and 5 Solution Cups

    Replacement Probe:Probe (PH105)

    0.00 to 14.00pH23 to 194F (-5 to 90C)0.01pH, 0.10.01pH, 1.8F/1C4 x CR2032 Button Batteries35.6 x 172.7 x 40.6mm110g

    Code:

    EX006

    Code:Eq5039

  • www.accepta.com 39

    Section 5.4EC400 - Extech Conductivity/TDS/Temp/Salinity Meter

    The waterproof ExStik Conductivity/TDS/Salinity Meter offers one high accuracymulti-range sensor which measures four parameters (Conductivity, TDS, Salinityand Temperature).

    Features Auto ranging meter offers 3 ranges to measure, pure water, salinity solu-

    tion, waste, boiler and cooling water using the same conductivity cell.

    6 units of measure: S/cm, mS/cm, ppm, ppt, mg/L and g/L.

    Internal memory stores up to 15 labelled readings for easy recall.

    Waterproof design to withstand wet environments meets IP57 Standard.

    Adjustable Conductivity to TDS ratio factor from 0.4 to 10 convenientlycalculates the TDS value with easy to replace conductivity cell module.

    Large digit, digital display with analog bar graph to indicate sample trends.

    Self calibration on power up, data hold, Auto Power Off & low batteryIndication.

    Automatic Temperature Compensation of 2% per C.

    Simultaneous display of Conductivity, TDS, or Salinity and temperature.

    EC400 includes meter and Conductivity cell, protective sensor cap,sample cup with cap, batteries and 1.2m neck strap.

    Specifications

    Conductivity:

    TDS:

    Salinity:

    Temperature:Power:

    Dimensions:

    Weight:

    Optional Extras:Weighted Base and 5Solution Caps

    Replacement Probe:EC405 Probe

    Ranges

    0 to 199.9S/cm200 to 1999S/cm2.00 to 19.99mS/cm0 to 99.9ppm (mg/L)100 to 999ppm (mg/L)1.00 to 9.99ppt (g/L)0 to 99.9ppm (mg/L)100 to 999ppm (mg/L)1.00 to 9.99ppt (g/L)32 to 149F (0 to 65C)4 x CR44W Batteries

    36 x 173 x 41mm

    110g

    Code:EX006

    Code:Eq5032

    Max Resolution

    0.1S/cm1S/cm0.01mS/cm0.1ppm (mg/L)1ppm (mg/L)0.01ppt (g/L)0.1ppm (mg/L)1ppm (mg/L)0.01ppt (g/L)0.1F/C

    Basic Accuracy

    2% FS

    2% FS

    2% FS

    1.8F/1C

  • www.accepta.com 40

    Section 5.5EC500 - Extech Combined pH/Conductivity/TDS/Temperature Meter

    The waterproof ExStik II pH/Conductivity Meter Combination comes with arugged flat surface pH electrode and an Auto-ranging high accuracy conductivitycell.

    Features

    Measures 5 parameters including Conductivity, TDS, Salinity, pH, andTemperature using one electrode.

    9 units of measure: pH, S/cm, mS/cm, ppm, ppt, mg/L, g/L, C, F

    Analog bargraph indicates trends.

    Memory stores up to 25 labelled readings

    Adjustable Conductivity to TDS ratio from 0.4 to 1.0; 0.5 fixed Salinity ratio.

    RENEW feature alerts user when electrode needs replacement.

    Auto Power Off and Low Battery Indicator & waterproof to IP57.

    EC500 meter includes electrode, protective sensor cap, sample cup withcap, four 3V CR-2032 button batteries and 1.2m neck strap.

    EC510 Kit includes EC500, 84S/cm, 1413S/cm and 12.88mS/cmcalibration standards, pH buffer pouches (1 each of 4, 7,10 pH plus rinsesolution), weighted base, 3 sample cups with caps and case.

    Specification

    Conductivity:

    TDS/Salinity:

    pH:

    Temperature:Waterproof:Memory:Dimensions:Weight:

    Optional Extras:Weighted Base and 5Solution Cups

    Replacement Probe:Probe (EC505)

    Range

    0 to 199S/cm200 to 1999S/cm2.00 to 19.99mS/cm0 to 99.9ppm (mg/L)100 to 999ppm (mg/L)1.00 to 9.99ppt0.00 to 14.00pH

    32 to 149F (0 to 65C)iP6725 datasets36 x 186 x 41mm110g

    Code: EX006

    Code: Eq5041

    Max Resolution

    0.1S/cm

    0.1ppm (mg/L)

    0.01pH

    0.1F/C

    Basic Accuracy

    2% FS

    2% FS

    0.01pH

    1.8F/1C

  • www.accepta.com 41

    Section 5.6CL200 - Extech Total Chlorine/Temperature Meter

    The waterproof ExStik CL200 Chlorine Meter gives a direct reading of TotalChlorine down to 0.01ppm and is unaffected by colour/turbidity of the sample.

    Features

    Direct reading of Total Chlorine provides fast and easy measurements (lessthan 2 minutes).

    Low detection limit down to 0.01ppm.

    Wide dynamic range of measurement up to 10ppm (use dilution method for10 to 50ppm).

    Unaffected by sample colour or turbidity.

    Automatic electronic calibration.

    Memory stores, tags and recalls up to 15 readings.

    Unique flat surface chlorine electrode.

    Waterproof to IP67 standard.

    The state of the art LCD simultaneously displays ppm of TotalChlorine and Temperature plus analog bargraph indicator.

    Complete with meter and flat surface Chlorine electrode, ExTab reagenttablets (50 tests), protective sensor cap, sample cup with cap, four 3VCR-2032 Button Batteries, and a 1.2m neck strap.

    Specifications

    Range in ppm: 0.01 to 10.00ppm (10 to 50ppm using dilution method)Temperature: 23 to 194F (-5 to 90C)Resolution: 0.01ppm ; 0.1F/CAccuracy: 10% of reading 0.01ppm; 1.8F/1CPower: 4 x CR-2032 Button BatteriesDimensions: 35.6 x 172.7 x 40.6mmWeight: 110g

    Optional Extras

    Weighted Base and 5 Solution Cups: Code: EX006Replacement Probe (CL205) Code: Eq5040

  • www.accepta.com 42

    Section 5.7DO600 - Extech Dissolved Oxygen/Temperature Meter

    The waterproof ExStik II Dissolved Oxygen Meter incorporates an easy toreplace screw on membrane cap with optional extension cables.

    Features

    Oxygen level displayed as % Saturation from 0 to 200.0% orConcentration from 0 to 17.00ppm (mg/L).

    Adjustable Altitude Compensation (0-20,000ft in 1,000ft increments).

    Adjustable Salinity Compensation from 0 to 50ppt.

    Analog bargraph indicates trends.

    Memory stores up to 25 data sets with DO and Temperature reading.

    Self calibration on power up.

    Data Hold, Auto Power Off, Low Battery Indicator.

    Waterproof to IP57.

    Optional 1m or 5m extension cable with probe weight.

    Complete with DO electrode, protective sensor cap, spare membrane cap,electrolyte, four 3V CR-2032 Button Batteries and 1.2m neck strap.

    Specification Range Max Resolution Basic Accuracy

    DO (saturation mode): 0 to 200.0% 0.1% 2% FSDO (concentration mode): 0 to 20.00ppm (mg/L) 0.01ppm (mg/L) 0.4ppm (mg/L)Temperature: 32 to 122F (0 to 50C) 0.1F/C 1.8F (1C)

    Dimensions 36 x 176 x 41mmWeight: 110gPower: 4 x CR2032 Button Batteries

    Optional Extras

    Weighted Base and 5 Solution Cups: Code: EX006

    Replacement Probe: Code: D0605

  • www.accepta.com 43

    Section 5.8RE300 - Extech ORP Meter

    The Extech ORP Meter has flat surface electrodes which provides On-the-Spotmeasurements and also has a large display with bar-graph.

    Features:

    ORP from 999 to 999mV, resolution of 1mV and 4mV accuracy.

    Automatic electronic self calibration.

    Simulated analogue bar graph displays change in ORP reading.

    Memory stores and recalls 15 readings and saves last calibrated value.

    Data validation indicators show user the reading is stabilised.

    Large 3-1/2 digit (2000 count) digital display with bar graph.

    Data Hold, Auto Shut-off and Low Battery Indicator.

    Easy to replace electrode module is interchangeable with pH and Chlorinemodules; (built in chip automatically recognises the type of probe pluggedin for specific measurements).

    Waterproof IP57 floats in water & protects the meter in wet environments.

    Complete with meter and electrode, protective sensor cap, sample cup withcap, four 3V CR-2032 Button Batteries and neck strap

    Specifications

    ORP (mV): 999 to 999mVResolution: 1mVAccuracy: 4mVPower: 4 x CR2032 Button BatteriesDimensions: 35.6 x 172.7 x 40.6mmWeight: 110g

    Optional Extras

    Weighted Base and 5 Solution Cups: Code: EX006

    Replacement Probe: (RE305) Code: Eq5031

  • www.accepta.com 44

    Section 5.9Refractometer - Glycol Tester (RefG300)

    Acceptas refractometer is a precision optical instrument designedto measure the concentration of Glycol as PEG or MEG displayedas a % and freeze point

    It is easy to use, you simply place a few drops of the treated solu-tion with the pipette included on to the prism glass and hold up tothe light. You can then read the concentration of Glycol in % orfreeze point on to the lens.

    Our Refractometer has a built-in automatic temperaturecompensation system.

    Measuring Range

    Ethylene Glycol: 60C - 0C with a resolution of 5C

    Polypropylene: 50C - 0C with a resolution of 5C

    Battery Acid: 1.100-1.400sg with a resolution of 0.01sg

    Other Refractometers for Coolants, Brix, Sugars etc. are available on request.Please contact us for details.

  • www.accepta.com 45

    Section 6.0Professional Test Meters

  • www.accepta.com 46

    Section 6.1Martini MI806 - 4 in 1 pH/Conductivity/TDS/Temp

    The Martini Mi806 is a multi-function portable meter measuringpH, Conductivity, TDS and temperature using a single probe.

    Measures 4 parameters with 1 single probe.

    You can select from a range of calibration buffers andalso the temperature scale (C or F).

    The multi-parameter probe Mi806P includes pH/EC/TDSand temperature sensors all in one rugged unit.

    TDS factors from 0.45 to 1.00, range of temperaturecoefficients () from 0.0 to 2.4% for greater reproducibility.

    Stability Indicator prompts when the reading stabilizes.Auto-Hold Function freezes reading for later viewing.

    Large and Easy-to-Read display provides simultaneousreadings of pH and Temperature or EC/TDS andtemperature

    Specifications

    Range: pHECTDSTemp

    Resolution: pHECTDSTemp

    Accuracy (25C): pHEC/TDSTemp

    Typical EMC Deviation: pHEC/TDSTemp

    Typical Compensation:

    pH Calibration:EC Calibration:EC/TDS Conversion Factor:Probe (Included):

    Environment:Battery Type (Included):Battery Life:Auto-off:Dimensions:Weight (with battery)

    0.00 to 14.00 pH0.00 to 20.00 mS/cm0.00 to 10.00 ppt0.0 to 60.0C / 32.0 to 140.0F0.01pH0.1 mS/cm0.01 ppt0.1C / 0.1F0.01 pH2% FS0.5C / 1F0.02 pH2% FS0.5C / 1FAutomatic from 0 to 60C;6 adj. from 0.0 to 2.4%/C1 or 2-point with automatic buffer recognitionAutomatic, 1 pointAdj. from 0.45 to 1.00Mi806P (MA851D/1) amplified pH/EC/TDS/Temperatureprobe with DIN connector and 1m cable

    0 to 50C / 32 to 122F; 100% RH max1 x 9ValkalineApprox. 300 hoursAfter 8 minutes200 x 85 x 50mm260g

    Replacment Probe: Code: MI806PMI806 Probe

  • www.accepta.com 47

    Section 6.2Eutech pH11 - pH/Temperature Meter

    The Eutech pH11 is a simple to use, accurate, reliablehand held meter which has been designed to handle thetough environment of field work.

    Large, Easy to Read display with simultaneousreadings with user-friendly icons.

    5-point Push-Button Calibration with Auto-Bufferrecognition for quick calibration with no mistakes.

    Automatic temperature compensation.

    Stores/Recalls up to 100 Data sets with temperaturereadings.

    Supplied with probe & batteries.

    Stability indicator prompts stable reading.

    Supplied with pH buffers solution 4.0 & 7.0

    Self-Diagnostic with message codes for easytroubleshooting.

    Specifications Ranges Max Resolution Basic Accuracy

    pH:mV:

    -2 to 16.000 to 1000 mV

    0.01pH0.01pH

    0.02 pH 2mV

    Temperature: -5 to 105C 0.1C 0.5C

    Power: 4 x AAA Batteries

    Dimensions: 85 x 185 x 40 mm

    Weight: 224g

  • www.accepta.com 48

    Section 6.3Eutech CON 11 - Conductivity Meter

    The Eutech CON 11 is a simple to use, accurate, reliablehand held meter which has been designed to handle thetough environment of field work.

    Large, Easy-to-Read LCD Display with simultaneousreadings and user-friendly icons.

    Stability indicator prompts when reading stabilizes.

    Auto - ranging Conductivity to detent the appropriatemeasurement range - ensures the best resolution.

    User Customisable Functions for options:Normalisation Temperature. Temperature coefficient,TDS factor & cell constant.

    Automatic temperature compensation.

    Supplied with calibration solution.

    Auto-off feature after 5 minutes to save battery life.

    Single & Multi-point Automatic or Manual Calibration.

    Specifications Ranges Max Resolution Basic Accuracy

    Conductivity: 0 to 19.99 S/cm20.0 to 199.9 mS/cm2.00 to 19.99 mS/cm20.0 to 199.9 mS/cm

    0.1S/cm0.01mS/cm

    0.1C

    1%

    1.8F/1C

    Temperature: -9 to 120C

    Power: 4 x AAA Batteries

    Dimensions: 85 x 185 x 40 mm

    Weight: 224g

  • www.accepta.com 49

    Section 6.4Eutech PC300 - Combined pH/Condy/TDS/Temp Meter

    The Eutech PC 300 is designed to readily withstand therigours of portable analysis, while reliably measuring pH,Conductivity and Temperature in a simple professionalmanner.

    Waterproof and Dust proof Housing - IP67 rated.

    Multi-parameter- toggle between pH/temperature andConductivity/temperature at touch of buttons.

    Multi-point Push-button Calibration (up to 3/4 points forpH/Conductivity) - for easy, quick calibration.

    Auto-Ranging for Conductivity measurements, fastresponse and best resolution over range.

    User-Customization for enhanced flexibility, viewing ofConductivity/TDS cell constants per range, electrodediagnosis, pH slope/offset/mV base value.

    Stability indicator prompts reading stability.

    Auto-Hold Function automatically freezes readingwhen stabilized for easy viewing and recording.

    Auto-Power Off saves battery power after non-use.

    Self-Diagnostic message codes for troubleshooting.

    Large Easy-to-Read Custom LCD with simultaneousdisplay for optimum viewing with user-friendly icons

    Specifications Ranges Max Resolution Basic Accuracy

    pH: -2 to 16.00 0.01pH 0.02 pH

    mV: 0 to 1000 mV 1 Mv 2mV

    Temperature: -5 to 105C 0.1C 0.5C

    Power: 4 x AAA Batteries

    Dimensions: 85 x 185 x 40 mm

    Weight: 224g

  • www.accepta.com 50

    Section 6.5Jenway 350 - pH Meter

    The Jenway 350 pH Meter offers simple yet professionalperformance for the operator who requires reliable resultsfrom trusted technology. With its single pH input andmanual temperature compensation the 350 is easy to use,but also offers such advanced features as the 32 readingnon-volatile memory.

    Features Power on self-check routine with 32 reading

    data storage.

    Environmentally protected case to IP65.

    Automatic or Manual calibration with 500hours battery life.

    Simultaneous pH and temperature reading.

    Full range of application specific electrodesand consumables.

    Specifications

    pH Range:Resolution (Accuracy):Manual Temperature Compensation:Resolution:Auto Buffer Recognition:Calibration:Power:Battery Life:Size:Weight:

    -2.00 to 16.00pH0.01pH ( 0.02pH)0 to 100C / 32 to 212F0.1C / 1F4.00, 7.00, 9.22 & 10.00 (manual override)User selectable 1 or 2 point2 x AA batteries500 hours typical (@25C with alkaline cells)175 x 75 x 35 mm250g

    The custom back-lit liquid crystal display simultaneously shows the pH reading and the manually settemperature compensation value that is simply adjusted with the up and down arrow keys. A one ortwo point calibration can be selected and, for ease of operation, automatic buffer recognition can beused. In special applications this can be overridden, enabling calibration to be set at any two pointsacross the full pH range.

    An indication of battery life is also permanently shown on the display. An automatic switch off facilityhelps to conserve battery life. This product is ideal for use in field or any portable situation.

  • www.accepta.com 51

    Section 6.6Jenway 470 - Conductivity/TDS/Temp Meter

    The Jenway 470 Conductivity/TDS/Temp Meter is a generalpurpose hand held meter offering a wide measuring range, whichis further complimented by the auto-ranging function that ensuresresults are displayed with the highest resolution that can beachieved.

    Features Automatic range selection for optimum resolution.

    Automatic or manual calibration.

    32 reading data storage.

    Conductivity and TDS modes.

    Power on self-test routine.

    Specifications:

    Conductivity:Ranges:Resolution (Accuracy):TDS Ranges:

    Resolution (Accuracy):Temperature Range:Resolution Accuracy:ATC & Manual ranges:Cell constant:Reference Temperature:Temperature Coefficient:Auto Standard Recognition:Probe input:Power:Battery Life:Size:Weight:

    6 switched ranges0 to 19.99S - 0 to 1999mS*0.1S to 1mS* (0.5% 2 digits)6 switched ranges0 to 19.99mg/l - 0 to 1999g/l*0.01mg/l to 1g/l* (0.5% 2 digits)-10 to 105C / 14 to 221F0.1C/1F (0.5C/1F)0 to 100C / 32 to 212FDigitally settable 0.01 to 19.9918, 20 or 25C settable0.00 to 4.00%/C linear10S, 84S, 1413S or 12.88mS (manual override)Mini-DIN conductivity/temperature2 x AA batteries500 hours typical (@25C with alkaline cells)175 x 75 x 35 mm250g

    * only with cell constant > 5

    Calibration can be carried out automatically against standard solutions at 10S, 84S, 1413S and12.88mS or a manual calibration can be made against any other standard value.

    Standard conductivity measurements can be made quickly and easily using the default settings butfor more complex applications a full range of adjustments can be made. The reference temperaturecan be set to 18, 20 or 25C and the temperature coefficient set from 0 to 4%/C. When using thealternative TDS range the E/C ratio can be set from 0.5 to 0.8 to ensure conformance with alloperating procedures.

    A simple dual function memory bar enables up to 32 readings to be stored and recalled from the non-volatile internal memory.

    An indication of battery life is also permanently shown on the display. An automatic switch off facilityhelps to conserve battery life. This product is ideal for field or any portable situation.

  • www.accepta.com 52

    Section 6.7Jenway 430 - Combined pH/Conductivity/TDS/Temp Meter

    The 430 is designed to readily withstand the rigours of portable anal-ysis, while reliably measuring pH and Conductivity in a simple andprofessional manner.

    Features

    Simultaneous readout of pH, Conductivity or TDS andtemperature

    Fully featured pH and Conductivity meters in a single,hand held unit

    Automatic or manual calibration of both functions Power on self-check routine Calibration diagnostics Environmentally protected case to IP65

    Specifications:

    pH Range (1 or 2 point call):Resolution:Accuracy:Conductivity Ranges:Resolution:Accuracy:TDS Ranges:Resolution:Accuracy:Temperature Ranges:Resolution:Accuracy:ATC Range:Manual Temp. Comp.:Auto Buffer Recognition:Auto Standard Recognition:Cell Constant:EC Ration (TDS):Reference Temperature:Temperature Coefficient:Power:Battery Life:Size:Weight:

    0 to 14pH0.01pH0.02pH5 switched ranges: 0 to 19.99S - 0 to 199.9mS0.01S, 0.S, 1S, 0.01mS, 0.1mS0.5% 2 digits5 switched ranges: 0 to 19.99mg/l - 0 to 199.9g/l0.01mg/l, 0.1mg/l, 1mg/l, 0.01g/l, 0.1g/l0.5% 2 digits-9.9 to +99.9C / 32 to 212F0.1C/ 1F0.5C / 1F0 to 99.9C / 32 to 212F0 to 99.9C / 32 to 212F4, 7, 9.22 and 10.00 (manual override facility)10S, 84S, 1413S & 12.88mS0.01 to 19.990.50 to 0.8018, 20 or 25C0.00 to 4%/C2 x AA batteries100 hours typical (@25C with alkaline cells)175 x 75 x 35 mm250g

    This product allows the simultaneous readout of pH, Conductivity or TDS and Temperature using thecustom backlit liquid crystal display. Calibrations are clearly indicated, together with the parameter inerror.

    It offers 1 or 2 point pH calibration and automatic buffer recognition with manual override.Conductivity calibration can be performed on standard solutions or by direct cell constant entry. Theconductivity/TDS range is automatically selected for optimum resolution and temperaturecompensated using an adjustable temperature coefficient.

    The 430 is supplied with a combined conductivity and pH probe assembly (a temperature sensor isalso incorporated to provide automatic temperature compensation). The probe connects to theinstrument via a single mini-DIN connector for operator convenience.

    An indication of battery life is also permanently shown on the display. An automatic switch off facilityhelps to conserve battery life. This product is ideal for field or any portable situation.

  • www.accepta.com 53

    Section 6.8TRANSEC - Conductivity/TDS/Salinity/Temp Meter

    The Conductivity/TDS Meter HC3010 is a highly sophisticated meter withability to automatically display and convert in Siemen (S), mSiemen (Ms),TDS in ppm and Salinity in ppt.

    The meter is versatile and able to preset at different conversion factors.User can select to display in Conductivity or TDS. Its 99 data memorycoupled with real time clock enable you to record reading with date andtime.

    For QC control, data can be analysed to display maximum and minimumreadings over all saved data. The meter comes complete in a hard casewith a set of calibration fluids for on the spot calibration.

    Auto-range measurement

    Multi range display of conductivity and TDS

    Dual conductivity or TDS and temperature reading display

    Save up to 99 data in memory with real time clock

    Able to show maximum and minimum reading over saved data

    Stability indicator prompts whenever reading stabilizes

    Automatic temperature compensation (ATC)

    Supplied with probe & batteries

    Auto-off feature to save battery life.

    Specifications Ranges Max Resolution Basic Accuracy

    Conductivity: 0 to 1999 S/cm 20 to 199.9 mS/cm2.00 to 19.99 ms/cm20.0 to 199.9 ms/cm

    0.1S/cm 0.01mS/cm

    Temperature: -5 to 105C 0.1C 1.8F/1C

    Power: 4 x AAA Batteries

    Dimensions: 40 x 195 x 36 mm

    Weight: 150g

  • www.accepta.com 54

    Section 6.9TRANSPH - pH (also ORP Meter with additional probe)

    The pH Meter HP3040 is a portable yet highly accurate pH meter.

    Used in all industries, the meter uses the regular BNC connector and ac-cepts a variety of electrodes for special measurement needs.

    The meter comes complete in a hard case with calibration buffer solutionsand offers ATC (automatic temperature compensation).

    Large LCD with multiple display, displays pH, temperature and timesimultaneously

    Multi point calibration - Automatic buffer recognition with built instandards pH 4, 7 & 10

    Custom set available - Manual set to any buffer standard

    Up to 5 point calibrations

    Capable of reading mV readings with additional probe

    Stores/recalls up to 99 data sets with date & time

    Supplied with probe & batteries

    Stability indicator prompts whenever reading stabilises

    Self- Diagnostic with message codes for easy troubleshooting

    Auto-off feature to save battery life

    NOTE: Additional probe required for ORP (mV) measurements - sold separately

    Specifications Ranges Max Resolution Basic Accuracy

    pH 0-14 0.01pH 0.02pH

    Temperature: -5 to 105C 0.1C 0.5C

    Power: 4 x AAA Batteries

    Dimensions: 40 x 195 x 36 mm

    Weight: 180g

    MV 0.1 to 199.9 mV / 0 to 1999 mV 0.2 mV / 2mV 0.2mV/2 mV

  • www.accepta.com 55

    Section 6.10Borescope/Wireless Inspection Camera - BR200/BR250

    Cooling tower fill Pack, Ductwork & Calorifier Monitoring

    Each Kit comes complete with: 4 x AA Batteries Rechargeable Display Battery Micro SD Card Memory card with SD Adapter USB Cable Video Interconnect Cable AC Adapter Magnetic Base stand and hard case

    We offer two affordable Borescopes

    The BR200 has a 17mm diameter camera head with a length of 1 meter which can be extended byuse of up to 2 extension cables each of 0.96m.

    The BR250 has a 9mm diameter camera head with a length of 0.9 meter which cannot be extended.

    Both cameras have a detachable wireless colour display which can be viewed at 10m from thesource and all images/video can be transferred to your PC via the microSD card (with included SDadaptor) or the USB cable (included) and viewed using Windows Media Player.

    The 9mm (BR250) and 17mm (BR200) cameras are waterproof and have 4 LED lamps with dimmerto illuminate the viewed object with a glare free close up field of view. The gooseneck cable retainsits configured shape.

    A memory card is includedfor capturing JPEGimages and video (AVI)with day time stamp.

    9mm or 17mm diametercamera head with flexiblegooseneck cable with 4 built inbright LED lights which easilyilluminate dark areas.

    The detachable wireless3.5 colour TFT LCD screencan be viewed form remotelocation up to 10m from thesource.

    Order Options:BR200 - 17mm diameter BorescopeBR250 - 9mm diameter BorescopeBR200-EXT - BR200 Borescope Extension Cable

  • www.accepta.com 56

    Section 7.0Drop Test Kits

  • www.accepta.com 57

    Section 7.1Drop Test Kits

    Acceptas high quality drop test kits are available in a range of parame-ter specific options to suit most analysis requirements. Each self con-tained kit is housed in its own rugged case and comes complete withtitration bottle, 65ml reagents, tablets or powders; a crushing rod (if re-quired) and an easy to follow waterproof instruction manual.

    Each drop test kit or replacement reagent pack includes reagentsnecessary to perform between 100 and 200 tests.

    Replacement reagents are available, refer to back of catalogue.

    Parameter Range Order Code

    Acid Strength 0-25% Drp19079

    Cleaning Acid Strength Tablets (100pk) Dt1025

    pH Test Strips 0-14 (100pk) Str6022

    Acidity 50-20,000 Drp19001

    PA1 (65ml) Dt1001

    ACD2 (65ml) Dt1002

    ACD3 (65ml) Dt1003

    Alkalinity P 5-2400 Drp19002

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    Alkalinity M 5-2400 Drp19003

    PA2/TA2 (65ml) Dt1005

    TA3 (65ml) Dt1006

    TA4 (65ml) Dt1004

    Alkalinity OH 5-2400 Drp19004

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    PA3 (65ml) Dt1007

    TA3 (65ml) Dt1006

    Alkalinity P, M & OH 5-2400 Drp19005

    PA1 (65ml) Dt1001

    PA2/TA2 (65ml) Dt1005

    PA3 (65ml) Dt1007

    TA3 (65ml) Dt1006

    TA4 (65ml) Dt1004

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 58

    Section 7.1Drop Test Kits (continued)

    Parameter Range Order Code

    Anionics (As Sodium Lauryl Sulphate) 5-2000 Drp19006

    P1/M (50ml) Dt1012

    P2/3 (65ml) Dt1013

    P9 (65ml) Dt1014

    P10 (65ml) Dt1015

    Bromine Total 0-20 Drp19007

    TBR1 (65ml) Dt1016

    TBR2 (65ml) Dt1017

    Carbohydarzide 5-50 Drp19074

    CZ1 (65ml) Dt1652

    CZ2 (65ml) Dt1653

    Carbon Dioxide 10-300 Drp19073

    PA1 (65ml) Dt1001

    CDX2 (65ml) Dt1646

    Chelant (Free) (as EDTA) 10-240 Drp19053

    FC1 (65ml) Dt1018

    FC2 (65ml) Dt1019

    FC3 (65ml) Dt1020

    Chelant LR (Total) (as EDTA) 10-240 Drp19008

    CT2 (65ml) Dt1022

    P1/4 Tablets (50pk) Dt1074

    Chloride LR & HR 0-3000 Drp19009

    BC1/CC1 (65ml) Dt1023

    BC2 (65ml) Dt1024

    CC2 (65ml) Dt1024

    Chlorine LR & HR (Free) 0-300 Drp19010

    FCL1 (65ml) Dt1027

    FCL2 (65ml) Dt1028

    CD4 (40g) Dt1077

    FCL3 (65ml) Dt1029

    Chlorine Dioxide ULR 0.05-1.0 Drp19072

    CD5 (40g) Dt1292

    CD7 (65ml) Dt1114

    CD6 (20g) Dt1293

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 59

    Section 7.1Drop Test Kits (continued)Parameter Range Order Code

    Chlorine Dioxide VLR 0-12 Drp19011

    CD01 (65ml) Dt1036

    CD02A (65ml) Dt1122

    Chlorine Dioxide LR 0-24 Drp19012

    CD01 (65ml) Dt1036

    CD02 (65ml) Dt1037

    CD02A (65ml) Dt1122

    Chlorine Dioxide VLR-HR 0-600 Drp19013

    CD01 (65ml) Dt1036

    CD02 (65ml) Dt1037

    CD02A (65ml) Dt1122

    CD03 (65ml) Dt1038

    Hardness Stop/Go 0-4 Drp19014S

    Hardness Stop/Go Solution (65ml) Dt1129

    Hardness Yes/No 0-20 Drp19014T

    Yes/No Hardness Tablets (50pk) Dt1121

    Hardness Calcium 5-1200 Drp19015

    CH2 (65ml) Dt1043

    CH1P (20g) Dt1050

    H/TH4/CH3 (65ml) Dt1049

    TH3 (65ml) Dt1044

    Hardness Total 5-1200 Drp19016

    TH3 (65ml) Dt1044

    TH2 (65ml Dt1046

    TH5 (65ml) Dt1047

    H/TH4/CH4 Dt1049

    Hardness Calcium & Total 5-1200 Drp19043

    CH2 (65ml) Dt1043

    TH2 (65ml Dt1046

    CH1P (20g) Dt1050

    TH5 (65ml) Dt1047

    H/TH4/CH3 (65ml) Dt1049

    TH3 (65ml) Dt1044

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 60

    Section 7.1Drop Test Kits (continued)Parameter Range Order Code

    Hydrogen Peroxide LR 1-100 Drp19051

    HP1 (65ml) Dt1051

    HP3 (65ml) Dt1053

    Hydrogen Peroxide HR 10-5000 Drp19017

    HP1 (65ml) Dt1051

    HP2 (65ml) Dt1052

    Hydrogen Peroxide LR & HR 5-5000 Drp19054

    HP1 (65ml) Dt1051

    HP2 (65ml) Dt1052

    HP3 (65ml) Dt1053

    Hypochlorite (Sodium) 0-15% Drp19060

    CL1P (20g) Dt1030

    CL2A (50pk) Dt1031

    CL5 (65ml) Dt1035

    CL2B (10g) Dt1032

    Iron VHR 50-6000 Drp19033

    HFE1 (65ml) Dt1055

    HFE2 (65ml) Dt1056

    HFE3 (20g) Dt1057

    HFE4 (65ml) Dt1058

    Molybdate LR 0-50 Drp19018

    MB1 (65ml) Dt1063

    MB2 (5g) Dt1064

    MB3 (65ml) Dt1065

    Nitrite 10-2000 Drp19020

    N1 (65ml) Dt1072

    N2 (65ml) Dt1073

    Peracetic Acid 10-6000 Drp19045

    CL2A (50pk) Dt1031

    CL2B (10g) Dt1032

    HP1 (65ml) Dt1051

    CL7 (65ml) Dt1054

    pH 4-12 Drp19022

    Universal pH Indicator Dt1164Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 61

    Section 7.1Drop Test Kits (continued)Parameter Range Order Code

    Phosphonate (Short) (HEDP & AMP or PBSAM) 0-20 Drp19023

    P1/4 Tablets (50pk) or Dt1074

    P1/4L (65ml) Dt1260

    P5 (65ml) Dt1075

    Phosphonate (S/Long) (HEDP & AMP or PBSAM)(Use in areas where the Alkalinity is greater than500ppm)

    0-20 Drp19059

    P1/2 (65ml) Dt1514

    P3 (65ml) Dt1080

    P4 Tablets (100pk) or Dt1080

    P4L (65ml Dt1291

    P5 (65ml) Dt1075

    Phosphonate (PBTC) 0-50 Drp19032

    PO1 (65ml) Dt1351

    PO2 (65ml) Dt1352

    PO3 (65ml) Dt1353

    Polyacrylate & Total Polymer 0-20 Drp19025

    A1 (65ml) Dt1082

    A2 (65ml) Dt1083

    A3 (100ml) Dt1087

    A4 (65ml) Dt1084

    A5 (65ml) Dt1085

    A6 (65ml) Dt1086

    25mm Filter Holder Eq5044

    0.45 filter papers (50pk) Eq5061

    Polyamine (as CTAB) 0-20 Drp19026

    P1/M (50ml) Dt1012

    P2/3 (65ml) Dt1013

    P4/2 (65ml) Dt1088

    QAC (cationic) 0-1000 Drp19027

    QA1 (65ml) Dt1089

    QA2 (65ml) Dt1090

    QA3 (65ml Dt1091

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 62

    Section 7.1Drop Test Kits (continued)Parameter Range Order Code

    Sulphite 5-300 Drp19028

    S1 (40g) Dt1092

    S2 (65ml) Dt1093

    Silver 0-60 Drp19080

    Silver Reagent (40g) Dt1727

    Silver Indicator (65ml) Dt1728

    Tannin 5-200 Drp19029

    TN1 (40g) Dt1094

    TN2 (65ml) Dt1095

    Total Oxidant 0.02-6.0 Drp19030

    TO1 (65ml) Dt1213

    TO2 (40g) Dt1214

    TO3 (40g) Dt1215

    TO4 (65ml) Dt1216

    Zinc 0-5 Drp19031

    Z1 (65ml) Dt1096

    Z4T (50pk) Dt1101

    Z5 (65ml) Dt1097

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 63

    Section 8.0MiniKits

  • www.accepta.com 64

    Section 8.1MiniKits

    Acceptas high quality MiniKits are available in a range of parameterspecific options to suit most analysis requirements.

    Each self contained kit is housed in its own rugged case and comescomplete with 30ml reagents, tablets or powders; a test bottle and easyto follow waterproof instructions. Each kit will perform between 30 and50 tests.

    Additional parameters and replacement reagents are also available,please refer to Replacement Reagents section.

    Parameter Range Order Code

    Acidity 5-6000 Min41001

    PA1 (30ml) Dt1001

    ACD3 (30ml) Dt1003

    Alkalinity P 5-2000 Min41002

    PA1 (30ml) Dt1001

    TA3 (30ml) Dt1006

    Alkalinity M 5-2000 Min41003

    TA3 (30ml) Dt1006

    TA4 (30ml) Dt1004

    Alkalinity OH 5-2000 Min41004

    PA1 (30ml) Dt1001

    PA3 (30ml) Dt1007

    TA3 (30ml) Dt1006

    Bromine Total 0-20 Min41005

    TBR1 (30ml) Dt1016

    TBR2 (30ml) Dt1017

    Chelant Total 0-240 Min41006

    P1/4L (30ml) Dt1260

    CT2 (30ml) Dt1022

    Chloride LR 5-200 Min41007

    BC1/CC1 (30ml) Dt1023

    CC2 (30ml) Dt1024

    Chloride HR 100-3000 Min41008

    BC1/CC1 (30ml) Dt1023

    BC2 (30ml) Dt1026

    Chlorine LR 2-30 Min41009

    FCL1 (30ml) Dt1027

    FCL2 (30ml) Dt1028

    Individual Replacement Components & complete Replacement Packs are available for each ofthe above parameters.

  • www.accepta.com 65

    Section 8.1MiniKits (continued)Parameter Range Order Code

    Hardness Calcium 10-1200 Min41012

    CH2 (30ml) Dt1043

    H/TH4/CH3 (30ml) Dt1049

    CH1P (10g) Dt1050

    Hardness Total 10-1200 Min41013

    TH2 (30ml) Dt1046

    H/TH4/CH3 (30ml) Dt1049

    TH5 (30ml) Dt1047

    Hydrogen Peroxide 10-5000 Min41022

    HP1 (30ml) Dt1051

    HP2 (30ml) Dt1052

    Molybdate 0-500 Min41027

    MLB1 (30ml) Dt1440

    MLB2 (30ml) Dt1441

    Nitrite 0-2000 Min41014

    N1 (30ml) Dt1072

    N2 (30ml) Dt1073

    pH 0-14 Min41016

    Universal pH Solution (30ml) Dt1164

    Phosphonate 0-20 Min41017

    P1/4L (30ml) Dt1260

    P5 (30ml) Dt1075

    Sulphite 5-200 Min41018

    S1 (20g) Dt1092

    S2 (30ml) Dt1093

    Tannin 10-300 Min41019

    TN1 (20g) Dt1094

    TN2 (30ml) Dt1095

    QAC Cationics 0-1000 Min41020

    QA1 (30ml) Dt1089

    QA2 (30ml) Dt1090

    QA3 (30ml) Dt1091

    Zinc 0-2 Min41021

    Z1 (30ml) Dt1096

    Z4T (30pk) Dt1101

    Z5 (30ml) Dt1097Individual Replacement Components & complete Replacement Packs are available for eachof the above parameters.

  • www.accepta.com 66

    Section 9.0Comparator Test Kits

  • www.accepta.com 67

    Section 9.1Comparator Test Kits

    Acceptas high quality comparator test kits are available in a rangeof parameter specific options to suit most analysis requirements.

    Each self contained kit is housed in its own rugged case and comescomplete with a high quality plastic comparator, comparator disk,reagents, liquids, tablets or powders; 2 x 10ml plastic cells, a tabletcrusher (if required) and an easy to follow waterproof instructions.

    Each comparator test kit or replacement reagent pack includesreagents necessary to perform between 50 and 100 parameterspecific tests.

    Parameter Range Order Code

    Aluminium 0-0.3 Com81001

    Aluminium Disk 256200

    Aluminium No1 Tablets (50pk) Dt1147

    Aluminium No2 Tablets (50pk) Dt1148

    Amine 0-15 Com81060

    Amine Disk 255005

    Amine Indicator Solution (65ml) Dt1643

    Amine Buffer Solution (65ml) Dt1644

    Amine Solvent (100ml) Dt1645

    Ammonia 0-1 Com81002

    Ammonia Disk 256210

    Ammonia No1 Tablets (50pk) Dt1245

    Ammonia No2 Tablets (50pk) Dt1244

    Bromine 0-5 Com81003

    Bromine Disk 256280

    DPD No1 Tablets (50pk) Dt1106

    DPD Nitrite Powder (20g) Dt1295

    Bromine (Liquid) 0-5 Com81003L

    Bromine Disk 256280

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD Nitrite Powder (20g) Dt1295

    Carbohydrazide LR 0-0.65 Com81049

    Carbohydrazide LR Disc 255011

    Carbohydrazide LR Solution (65ml) Dt1654

    Carbohydrazide LR Indicator (65ml) Dt1741

    Individual Replacement Components & complete Replacement Packs are available for eachof the above parameters.

  • www.accepta.com 68

    Section 9.1Comparator Test Kits (continued)Parameter Range Order CodeChlorine VLR 0-1 Com81004

    Chlorine VLR Disc 256010

    DPD No1 Tablets (50pk) Dt1106

    DPD No3 Tablets (50pk) Dt1107

    Chlorine VLR (Liquid) 0-1 Com81004L

    Chlorine VLR Disc 256010

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD No3 Solution C (30ml) Dt1507

    Chlorine LR (Free & Total) 0-4 Com81005

    Chlorine LR Disc 256020

    DPD No1 Tablets (50pk) Dt1106

    DPD No3 Tablets (50pk) Dt1107

    Chlorine LR (Liquid) 0-4 Com81005L

    Chlorine LR Disc 256020

    DPD No1 Solution A (30ml) Dt1505

    DPD No1 Solution B (30ml) Dt1506

    DPD No3 Solution C (30ml) Dt1507

    Chlorine HR (Total) 10-300 Com81006

    Chlorine HR Disc 256030