accessories - promoterm€¦ · for controlling a solar installation with calorifier fitted with 1...

4
www.dedietrich-heating.com 278 Solar installations 15 Package Ref. DMCDB Energy transfer station from one storage tank to another and vice versa. Is fitted with 2 pumps (EEI 0.23) and a 3-way valve; its design allows it to be connected directly to both tanks. The loading and unloading module allows the heat transfer between 2 tanks. ER468 7604939 ER301 + ER 666 DB20 Drain-Back solar trasnfert module Wall-hung, self draining, solar station for installing up to 20 m 2 of flat collectors. It helps to prevent overheating and is particulary suitable for installations with random requirements (schools, crèches, etc...) Use with DIETRISOL PRO C 250 collectors Extra storage with DB20 module To handle installations of up to 25 m 2 of collectors. ER301 ER666 100017486 7619965 LOAD/UNLOAD STATION OR ENERGY TRANSFER 8980Q314A DB20_Q0003 A En B C D E F G A e y r i g νεργεια Package Ref. Solar station SKS 13-45 For installations with up to 40 m 2 of collectors (manometric height of the solar pump 13 mCE) with solar calorifiers with built in exchanger or external plate exchanger These solar stations are fitted with all components required to enable optimum operation of the solar installation: solar pump, non-return valves, safety valve, manometer, air/water separator with manual air vent, filling and draining system, thermometers… Option of including a SOL PLUS control unit. ER665 7619964 8980F169 Accessories for collective solar installations SOLAR STATION FOR SYSTEMS WITH BPB/BLC/B 600 TO 3000, B 802 AND 1002, PS 600 TO 3000 CALORIFIERS SK_Q0001 TRANSFERT UNIT SKS 13-45 TRANSFER UNITS STS 14-30, 14-50, 14-100, D14-200 AND 12-400 CME Package Ref. ER667 ER668 ER669 ER670 ER671 Transfer units STS 14-30 CME (1) Transfer units STS 14-50 CME (1) Transfer units STS 14-100 CME (1) Transfer units STS D 14-200 CME (1) Transfer units STS D 12-400 CME (1) For installations with up to 400 m 2 of collectors, with exchanger suitable for DHW and heating water Use: These stations are suitable for installations with DIETRISOL PRO C 250 or POWER collectors combined with tanks with no integrated exchanger. Construction : these stations are fitted with all the components needed to allow optimum operation of the solar installation with plate exchanger in "low flow" (15 l/m 2 .h) with the SOL SC. 5 control system: - delivered preset with STS 14-50 and 14-100 CME stations, - delivered with STS D 14-200 and D 12-400 CME for connection to the station via a bracket to fixed to the wall All the valves, pumps, etc. have been sized in relation to operating requirements according for the "low flow" principle of De Dietrich solar systems. Included for all stations are: the plate exchanger, the primary and secondary pumps, the 6-bar safety valve (primary and secondary circuit), the anti-thermosiphon valves, the pressure gauge, the filling and drainage valves, the thermometers. All these transfer stations are, as standard, equipped with a volumetric energy meter for an accurate count of contribution solar. The STS 14-200 and 12-400 CME are made respectively of 2 or 3 solar stations mounted in cascade or an aluminium frame. ER667 ER668 ER669 ER670 ER671 7619966 7619967 7619968 7619970 7619971 (1) Solar station STS : available only on order. If hard water, a water softener is imperative to product. SOLAR STATION/SOLAR TRANSFER UNITS FOR SYSTEMS WITH FWS OR RSB CALORIFIER SK_Q0011 SK_Q0009 SK_Q0007 SK_Q0005 SK_Q0003

Upload: haque

Post on 15-Jul-2018

216 views

Category:

Documents


0 download

TRANSCRIPT

www.dedietrich-heating.com278

Sol

ar in

stal

lati

ons

15

Package Ref.DMCDBEnergy transfer station from one storage tank to another and vice versa. Is fitted with 2 pumps (EEI � 0.23) and a 3-way valve; its design allows it to be connected directly to both tanks.The loading and unloading module allows the heat transfer between 2 tanks.

ER468 7604939

ER301 + ER 666 DB20 Drain-Back solar trasnfert moduleWall-hung, self draining, solar station for installing up to 20 m2 of flat collectors. It helps to prevent overheating and is particulary suitable for installations with random requirements (schools, crèches, etc...)Use with DIETRISOL PRO C 250 collectors

Extra storage with DB20 moduleTo handle installations of up to 25 m2 of collectors.

ER301

ER666

100017486

7619965

load/unload Station or energy tranSFer

8980

Q31

4AD

B20_

Q00

03

A

En

BCDEFG

Ae e

y a

r i g νεργεια

PICTO_ENERGIE_A-A

Package Ref.Solar station SKS 13-45➪ For installations with up to 40 m2 of collectors (manometric height of the solar pump 13 mCE) with solar calorifiers with built in exchanger or external plate exchangerThese solar stations are fitted with all components required to enable optimum operation of the solar installation: solar pump, non-return valves, safety valve, manometer, air/water separator with manual air vent, filling and draining system, thermometers… Option of including a SOL PLUS control unit.

ER665 7619964

8980F169

1

2

3

4

5

8980

F169

Accessoriesfor collective solar installations

Solar Station For SyStemS With BPB/BLC/B 600 to 3000, B 802 and 1002, PS 600 to 3000 caloriFierS

SK_Q

0001

➪ tranSFert unit SKS 13-45

➪ tranSFer unitS StS 14-30, 14-50, 14-100, d14-200 and 12-400 cmePackage Ref.

ER667

ER668

ER669

ER670

ER671

Transfer units STS 14-30 CME (1)Transfer units STS 14-50 CME (1)Transfer units STS 14-100 CME (1)Transfer units STS D 14-200 CME (1)Transfer units STS D 12-400 CME (1)

➪ For installations with up to 400 m2 of collectors, with exchanger suitable for DHW and heating waterUse: These stations are suitable for installations with DIETRISOL PRO C 250 or POWER collectors combined with tanks with no integrated exchanger.Construction : these stations are fitted with all the components needed to allow optimum operation of the solar installation with plate exchanger in "low flow" (15 l/m2.h) with the SOL SC. 5 control system:- delivered preset with STS 14-50 and 14-100 CME stations,- delivered with STS D 14-200 and D 12-400 CME for connection to the station via a bracket to fixed

to the wallAll the valves, pumps, etc. have been sized in relation to operating requirements according for the "low flow" principle of De Dietrich solar systems.Included for all stations are: the plate exchanger, the primary and secondary pumps, the 6-bar safety valve (primary and secondary circuit), the anti-thermosiphon valves, the pressure gauge, the filling and drainage valves, the thermometers. All these transfer stations are, as standard, equipped with a volumetric energy meter for an accurate count of contribution solar.The STS 14-200 and 12-400 CME are made respectively of 2 or 3 solar stations mounted in cascade or an aluminium frame.

ER667ER668ER669ER670ER671

76199667619967761996876199707619971

(1) Solar station STS : available only on order. If hard water, a water softener is imperative to product.

Solar Station/Solar tranSFer unitS For SyStemS With FWS or rSb caloriFier

SK_Q

0011

SK_Q

0009

SK_Q

0007

SK_Q

0005

SK_Q

0003

Sol

ar in

stal

lati

ons

15

279www.dedietrich-heating.com

Accessoriesfor collective solar installations

Solar control SyStemS and optionS

Package Ref.

SOL_

Q00

01

SOL PLUS control systemFor controlling a solar installation with calorifier fitted with 1 or 2 exchanger enabling heating zone reversal solar heating system with 3-way boiler return relief valve on the heating return circuits. Delivered with 3 sensors (TC, TS and TR).

ER709 7630422

8980

Q03

5

Regulation SOL SC. 5For controlling a solar installation with 1 or 2 collector fields and 1 or 2 solar calorifiers (one of which may have heating zone reversal) or 1 solar calorifier and 1 swimming pool with load and unload control and recover the return temperature. Delivered with 4 sensors (TC, TS, TP and TE).

ER672 761997289

80Q

317

DELTASOL E Control systemControl system designed to manage all solar installation with more than 2 primary and secondary circuits and a plate exchanger.

ER315 100017500

DB_

Q00

03

Regulation SOL AELFor controlling a solar installation with 1 calorifier fitted with 1 exchanger. Delivered with 2 sensors (TC and TS). The unit is able to control the heating/electrical back-up

ER708 7630421

8980

Q03

5

Differential control system MCDBDifferential control system used to load 1 DHW calorifier from a buffer volume (solar or wood-field boiler), or transfer energy from one storage tank to another and vice versa.

8980F243

MCDB

MCDB

DMCDB

8980

F243

EC162 100004650

8980

Q24

0

3-way valve 3/4" with reversal motorFor solar circuit with 2 tanks and Sol control system.

EC164 89804803

8980

Q26

0

Kit with 2 valves + sensorFor controlling an installation with 2 EAST/WEST collector fields with SOL SC. 5.

EC432 100011341

SOL_

Q00

03

Conencting kit (PWM) for a 2 solar pumpsAllows the connection of a second solar pump on the SOL PLUS control system.(installation with 2 tanks or 2 x East/west colelctor fields.

ER712 7630423

SOL_

Q00

02

ModBUS connecting cable (3m)For connection between a SOL PLUS control system and a DIEMATIC iSystem control panel.

ER713 7630424

8980

Q26

3

Energy metering kitComprises a flow rate meter (1.5 m3/h max. flow rate) and 2 sensors. Used to meter energy accurately in solar installations. It must be mounted in the solar circuit.

EC174 100004652

8980

Q28

9

AM1 breakdown report moduleWarns of operating errors by flash signal and any breakdown report on a building management system for DIEMASOL or SOL. control system.

ER314 100017499

8980

Q28

1

Irradiation sensor CS 10With STS station only. Replace the collector sensor who has to stay on the solar installation.

EC175 89804815

8980

Q27

9

Lightning conductor boxFor SOL control system. Protects the control system against power surges if the collectors field is struck by lightning.

EC176 89804816

Sol

ar in

stal

lati

ons

15

www.dedietrich-heating.com280

Accessoriesfor collective solar installations

other acceSSorieS

DESCRIPTION PACKAGE REF.SLA 2 differential control system EC320 100007832Expansion vessel:- 18 litres EG117 100019427- 24 litres EG118 100019428- 50 litres EG83 89807772- 60 litres EG84 89807773- 100 litres EG120 100008733- 200 litres EG122 100008735- 300 litres EG123 100008736Wall bracket for expansion vessel up to 25 litre EC118 89807238Thermostatic mixing valve for a DHW flow up to 39 l/h (DHW flow at ∆P = 1.5 bar) EG78 89807767

Collector sensor PT 1000 EC155 100008011Dip sensor PT 1000 EC173 100004651Contact sensor PT 1000 EC171 100003690

DESCRIPTION PACKAGE REF.Heat transfer fluid:- High performance pre-mix type LS,

20 litres (-28°C) EG100 89807792

- Pre-mix "BIO" (-30°C) low viscosity high resistance on the corrosion and freez without BORAX type LR-25 (20 litres)

ER316 100017611

DESCRIPTION PACKAGE REF.Filling station with pump and car EG81 89807770Hand pump for tapping up with fluid EG80 89807769Check box for solar installation ER50 100012031Antifreeze protection tester (for checking the heat transfert fluid) EG102 89807797

Measuring box with refractometer EG104 89807799Cleaning material for solar circuit solRnet ER318 100020025

8980

Q04

3

EG117

8980

Q03

8

EG109EG110

8980

Q07

2

EG376

8980

Q03

7

DUO-Tube

DB2

00_Q

0008

ER319

8980

Q07

1

EG374EG375

8980

Q25

1

DUO-flex

DESCRIPTION PACKAGE REF.Double, pre-insulated “DUO-TUBE” or “DUO-FLEX” pipes with UV protection and cable for sensor (bicone connectors are to be ordered separately) :- Duo-Tube Cu 10 x 10 m ER319 100020297- Duo-Tube Cu 15 x 10 m EG106 89807000- Duo-Tube Cu 15 x 15 m EG107 89807001- Duo-Tube Cu 18 x 15 m EG108 89807002- Duo-Flex in ribbed stainless steel Ø 16 x 15 m

(with easyclic connection) EG422 7648217

- Duo-Flex in ribbed stainless steel Ø 20 x 15 m EG423 7648218- Duo-Flex in ribbed stainless steel Ø 20 x 20 m EG424 7648219- Duo-Flex in ribbed stainless steel Ø 25 x 25 m EG426 7648220Set of collars “Duo-Tube” and "Duo-Flex":- for Duo-Tube Cu 15 and Duo-Flex Ø 16mm,

4 parts EG109 89807003

- for Duo-Tube Cu 18 and Duo-Flex Ø 20mm, 4 parts EG110 89807004

Set of bicone connectors for “Duo-tube” or “Duo-Flex” (without soldering):- Set of 2 bicone connectors Ø 15mm

(for Duo-tube) EG374 100000417

- Set of 2 bicone connectors Ø 18mm (for Duo-tube) EG375 100000418

- Set of 2 bicone connectors Ø 15/18mm (for Duo-tube and Duo-Flex) EG376 100000419

2 easy clic connections for Duo-Flex Ø 25 mm - 1" 1/4 F EG427 7648221

➪ duo-tube

Sol

ar in

stal

lati

ons

15

281www.dedietrich-heating.com

Accessoriesfor collective solar installations

Package Ref.Hot fluid meters- 3.5 m3/h- 2.5 m3/h- 1.5 m3/hUltrasound energy meters, compatible with a 130°C heat-transporting fluid, ACS approvedACS cold water meters- 20 m3/h- 10 m3/h- 5 m3/h- 3.5 m3/hACS approved class C ultrasound flow rate meters for cold water with consumption totaliser

ER312ER311ER310

ER317ER309ER308ER307

100017497100017496100017495

100019195100017494100017493100017492

Energy metering WMZ kitAllows the meter energy in a hydraulic system. It is used in addition to the volumetric flow meter - package EC174.

ER131 100014590

CME energy measurement unitCan be used to track, totalise and take stock of the energy individually contributed to a hot water production system (for a GRS, for example) by a multi-energy system (solar + gas, fuel oil or electric back-up).The CME can track 4 fluid circuits, 2 electric circuits (Finder 7E) and 1 gas meter (ITRON Gallus or RF1). It can be connected to our DELTASOLs & DIEMASOLs by VBus and the DL 2 communication interface for remote control of the installation.

ER313 100017498

DL2 communication interfaceThe DL 2 handles communication between the solar control system and a computer. It can be used: to display all the operating statuses and modes of a solar installation, check efficiency, detect simple default and transmit data directly to a PC or a router for remote inquiries. Software for downloading data is delivered with the interface.

ER55 100013514

DL3 communication interfaceThe DL 3 has the same functions as the DL 2 interface, but is designed to centralise the data from 3 installations (or 3 solar control systems combined with 3 CME measurement units and/or WMZ measurement units). Software for downloading data is delivered with the interface.

ER139 100019224

Dip sensorPT1000

EC173 100004651

Contact sensorPT1000

EC171 100003690

Connection cable BUSLength 40 m.

DB119 81997720

energie metering

8980

Q28

789

80Q

272

8980

Q30

189

80Q

254

8980

Q25

58

19

9Q

06

389

80Q

035

8980

Q28

6