accessories - marvin adm accessories.pdf · accessories-1 19972255 marvin architectural detail...
TRANSCRIPT
AccessoriesInstallation Bracket, Nailing Fin, Drip Cap and Jamb Extension ............................................................................ 1
Interior Trim and Interior Round Top Trim.............................................................................................................. 3
Wood Exterior Mullion Trim and Wood Exterior Casing ......................................................................................... 4
Wood Subsills......................................................................................................................................................... 5
Wood Special Profile Exterior Casings................................................................................................................... 7
Clad Extrusion / Clad Casing ................................................................................................................................. 9
Clad Special Subsill Profiles................................................................................................................................... 11
Lineal Subsill Caps / End Caps.............................................................................................................................. 12
Round Top Shapes ................................................................................................................................................ 13
Clad Special Application for Windows - Casing All Sides ...................................................................................... 14
Clad Special Application for Windows - Columbus Casing Stick Construction ...................................................... 15
Clad Special Application for Windows - Columbus Casing Masonry Construction ................................................ 16
Clad Special Casing for Windows - Grayson Casing Stick Construction ............................................................... 17
Clad Special Casing for Windows - Grayson Casing Masonry Construction ......................................................... 18
Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Stick Construction .................................................... 19
Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Masonry Construction .............................................. 20
Clad Special Casing for Windows - Ridgeland Casing Masonry Construction....................................................... 21
Clad Special Casing for Windows - Stratton Casing Masonry ............................................................................... 22
Clad Special Casing for Windows - Thorton Casing Masonry Construction .......................................................... 23
Clad Special Casing for Windows - Potter Casing Wood Frame Construction ...................................................... 24
Clad Special Casing for Windows - Potter with Trim Casing Masonry Construction.............................................. 25
Wood Special Casing for Windows - Special Casing 3 (SPC3) ............................................................................. 26
Wood Special Casing for Windows - Special Casing 7 (SPC7) ............................................................................. 27
Wood Special Casing for Windows - Special Casing 21 (SPC21) ......................................................................... 28
Wood Special Casing for Windows - Special Casing 18 (SPC18) ......................................................................... 29
Wood Special Casing for Windows - Special Casing 26 (SPC26) ......................................................................... 30
Clad Special Casing for Doors - Wood Frame Construction - All Casings Options ............................................... 31
Clad Special Casing for Doors - Masonry Construction - All Casing Options ........................................................ 32
Clad Applications.................................................................................................................................................... 33
i 19972255Marvin Architectural Detail Manual
Accessories
Installation Bracket, Nailing Fin, Drip Cap and Jamb ExtensionNot to Scale
Misc1199
Misc0500
Misc076
Misc048
Installation BracketMisc. 048 - 6 3/8" (162) lengthIncludes flathead wood screws
Installation BracketMisc. 076 - 9 3/8" (238) lengthsIncludes flathead wood screws
Installation BracketMisc. 0500 - 15 3/8" (391) lengths
Includes flathead wood screws
Structural BracketMisc. 1199 - 6 3/8" (391) or 10" (254) lengths
Includes flathead wood screws
Installation Fin / Drip Cap
V084NAILING FIN
V087CONNECTING BARB
V088NAILING FIN
V104NAILING FIN HINGED VINYL NAILING FIN-SIDE
V112
HINGED VINYL NAILING FINV110
V226DRIP CAP - VINYL
- For use at Head Jamb. Optional for Wood Round Top units
- For use with Clad Round Top Units
- For use at side jambs and sill for Bow and Bay assemblies
DRIP CAP-VINYLV119
- For use at Head Jamb.For use with wood or clad unit including Brick Mould Casing.
Radius, for use at Round Top Unit
- For use at Side jambs
DRIP CAP-ALUMINUMA100
-For use at Head Jamb.For use with wood or clad unit including
Brick Mould Casing.Available in Bronze, Brown, Evergreen,
Pebble Gray and White
ACCESSORIES-1 19972255Marvin Architectural Detail Manual
Ver 2013.2 2013-08-26
Accessories
Jamb ExtensionNot to Scale
1"(25)
11/16"(17)
W6120 - 1" (25)W6279 - 2’ (51)W6378 - 3" (76)
W6380 - 12" (305)
W60124 9/16" to 5 3/16"
(116 to 132)
W60114 9/16" to 5 1/16"
(116 to 129)
W60104 9/16" to 4 13/16"
(116 to 122)
11/16"(17)
5/8"(16)
11/16"(17)
1/2"(13)
11/16"(17) 1/4"
(6)
1 3/32"(28)
11/16"(17)
W2109 - 1" (25) For CUDH
1/2"(13)
2 3/32"(53)
11/16"(17)
2"(51)
W2059 - 2" (51) For CUDH
11/16"(17)
3 3/32"(79)
1/2"(13)
W1071 - 3" (76) For CUDH
1/2"(13)
4 3/32"(104)
W1069 - 4" (102) For CUDH
1/2"(13)
11/16"(17)
6 3/32"(155)
W1067 - 6" (152) For CUDH
ACCESSORIES-2 19972255Marvin Architectural Detail Manual
Ver 2012.1 2012-12-17
Accessories
Interior Trim and Interior Round Top TrimNot to Scale
1 3/16"(30)
1/4"(6)
1/4"(6) 7/8"
(22)
1/4"(6) 7/8"
(22)1 1/16"
(27)
1/4"(6)
1 7/16"(37)
1/4"(6)
W1065 - Mullion TrimFor CUDH Vertical
W1195 - Mullion TrimFor Inswing French Door
W1241 - Mullion TrimTilt-Turn, Hopper
W1242 -Mullion Trim
Interior Trim
Interior Round Top (Available in Oak or Pine)
2 1/4"(57)
5/8"(16)
W1144 - Used as optional interior casing for RT and
Arch French Door Only
2 1/2"(63)
21/32"(17)
W1445- Used as optional interior casing for RT and
Arch French Door Only
21/32"(17)
3 1/4"(83)
W1351 - Used as optional interior casing for RT and
Arch French Door Only
21/32"(17)
2 3/16"(56)
W1366 - Used as optional interior casing for RT and
Arch French Door Only
2 1/4"(57)
21/32"(17)
W1376 - Used as optional interior casing for RT and
Arch French Door Only
ACCESSORIES-3 19972255Marvin Architectural Detail Manual
Ver 2016.5 2016-10-31
Accessories
Wood Exterior Mullion Trim and Wood Exterior CasingNot to Scale
NOTE: 5/4 casing greater than 10", contact your Marvin representative
W1185
3/8"(10)
1 13/16"(46)
W1189
3/8"(10)
1 13/16"(46)
W1187
3/8"(10
1 13/16"(46)
W1034 - For Ultimate Gilder W1094 - For Magnum Double Hung
W1242 - for 3/8” MullionReinforcement
Wood Exterior Mullion Trim
2"(51)
1 7/32"(31)
2"(51)
1 7/32"(31)
1 3/32"(28)
3 1/2"(89)
13/16"(21)
11/16"(17)
Exterior Casing
1 7/32"(31)
2"(51)
1 7/32"(31)
2"(51)
11/16"(17)
9/32(7)
1 3/32"(28)
3 1/2"(89)
13/16"(21)
11/16"(17)
1 3/32"(28)
2 1/4"(57)
3 1/2"(89)
1 3/32"(28)
3 1/2"(89)
1 3/32"(28)
9/32"(7)
11/16"(17)
W1047 - Brick Mould Casing
W1039 - Stucco Brick Mould Casing
W1047 - Flat Casing Top casing for Sliding, Swinging and French
Doors Includes Screen Kerf
W6533 - Brick Mould Casing
For Sliding French Door
W1049 - Stucco Brick Mould CasingSide Casing for Sliding,
Swinging and French Doors
W1076 - Flat CasingSide Casing for Sliding,
Swinging and French Doors
Flat Casingavailable from 2" to 10" W1035 - Stucco Flat Casing
3 1/2” for top casingW1030 - Stucco Flat Casing
3 1/2” for side casing
ACCESSORIES-4 19972255Marvin Architectural Detail Manual
Ver 2014.1 2014-01-23
Accessories
Wood SubsillsNot to Scale
NOTE: For product compatibility, see chart on next page.
3 17/32"(90)
W8063 - 2" Simulated Thick Subsill
2 9/32"(58)
W10341 - 2" Extended Simulated Thick Subsill
1 3/32"(28)
3 17/32"(90)
2 9/32"(58)
15/16"(24)
2"(51)
2"(51)
W10340 - 2" Simulated Thick Subsill
2 3/4"(70)
2"(51)
15/16"(24)
1 13/16"(46)
2 3/4"(70)
W2165 - 2" Simulated Thick Subsill
2"(51)
1 3/32"(28)
1 13/16"(46)
2 27/32"(72)
W2122 - Narrow Subsill
1 1/4"(32)
1 1/16"(27)
1 15/32"(37)
W2124 - Cut Back Subsill
15/16"(24)
2 3/4"(70)
W2134 - Subsill
1 3/32"(28) 29/32"
(23)
2 3/4"(70)
W10333 - Subsill
15/16"(24) 3/4"
(19)
ACCESSORIES-5 19972255Marvin Architectural Detail Manual
Ver 2016.4 2016-08-29
Accessories
Wood SubsillsNot to Scale
NOTE: For product compatibility, see chart below.
3 29/32"(99)
1 3/32"(28) 3/4"
(19)
W8002 - 2 1/2" Extended Subsill
4 5/32"(106)
1 3/32"(28) 23/32"
(18)
W8003 - 2 3/4" Extended Subsill
4 29/32"(125)
W8005 - 3 1/2" Extended Subsill
1 3/32"(28) 5/8"
(16)
4 29/32"(125)
W10342 - 3 1/2" Extended Subsill
15/16"(24) 15/32"
(12)
Part # Description Product Compatibility
W8063 2" Simulated Thick Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W10341 2" Extended Simulated Thick Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA
W10340 2" Simulated Thick Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA
W2165 2" Simulated Thick Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W2122 Narrow Subsill WMTT
W2124 Cut Back Subsill WMTT
W2134 Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W10333 Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA
W2120 Extended Subsill WMTT
W8002 2 1/2" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W8003 2 3/4" Extended Sudsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W8004 3" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W8005 3 1/2" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT
W10342 3 1/2" Extended Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA
ACCESSORIES-6 19972255Marvin Architectural Detail Manual
Ver 2016.4 2016-08-29
Accessories
Wood Special Profile Exterior CasingsThese sections illustrate the profile of each special casing and their dimensions. Each casing is labeled with its availability for linealand/or round top units. Not all casings are applicable and varying conditions may require consideration for units including screens,combinations, mullions, etc. and may require extended sills. Illustrations shown are not to scale.
3 11/32"(85)
1 13/16"(46)
1 1/4"(32)
2"(51)
2"(51)
3 1/4"(83)
2"(51)
2"(51)
11/16"(17)
1 1/4"(32)
11/16"(17)
2"(51)
1 1/16"(27)
3 1/2"(89)2 7/8"
(73)
1 7/32"(31) 1 1/4"
(32)
3 1/2"(89)
1 1/2"(38)
2"(51)
2 1/2"(63)
1 1/4"(32)
2"(51)
2"(51)
1 1/4"(32)
1 1/4"(32)
2"(51)
1 1/2"(38)
1 3/16"(30)
1 3/4"(44)
1 3/4"(44)
1 1/4"(32)
2 1/16"(52)
2"(51)
9/16"(14)
1 3/16"(31) 1 1/16"
(27)
1 3/4"(44)
11/16"(17)
1 1/4"(32)
1 7/8"(48)
3/4"(19)
Lineal & Round TopSPC 21
SPC 16SPC 15
Lineal & Round TopSPC 20
Lineal & Round TopSPC 19
Lineal OnlySPC 22
Lineal & Round TopSPC 18SPC 17
Lineal Only
SPC 14Lineal & Round Top
SPC 13Lineal & Round Top
Lineal & Round TopSPC 10
SPC 6Lineal & Round Top
SPC 2Lineal & Round Top
SPC 1Lineal Only Lineal & Round TopLineal & Round Top
Lineal & Round TopLineal OnlySPC 7
Lineal & Round TopSPC 8
SPC 4SPC 3
SPC 5
Lineal & Round TopSPC 9
Lineal OnlyLineal Only
SPC 12Lineal & Round TopLineal Only
SPC 11
1 1/16"(27)
1 1/4"(32)
ACCESSORIES-7 19972255Marvin Architectural Detail Manual
Ver 2015.1 2015-07-09
Accessories
Wood Special Profile Exterior CasingsNot to Scale
NOTE: Please contact your Marvin representative for specific information and requirements of special casing.
2"(51)
1 3/32"(28)
2"(51)
1 1/4"(32)
1 3/4"(44)
1 3/4"(44)
1 3/4"(44)
1 7/8"(48)
2 5/8"(67)
2 1/2"(64) 1 3/8"
(35)
1 3/4"(44)
2 1/2"(64)
11/16"(17)
1 3/8"(35)
1 3/4"(44)
1 11/16"(43)
2"(51)
1 11/16"(43)
1 5/16"(33)
1 1/2"(38)
1 1/4"(32)
1 5/8"(41)
1 1/4"(32)
1 1/4"(32)
2 1/2"(64)
1 5/8"(41)
1 7/16"(37)
2 9/16"(65)
1 1/2"(38)
2 5/8"(67)
3 1/2"(89)
1 3/32"(28)
5"(127)1 21/32"
(42)
1 5/32"(29)
2"(51)
2"(51)
4"(102)
1 3/32"(28) 1 7/8"
(48)
1 3/4"(44)
1 9/16"(40)
1"(25)
SPC 41
SPC 39Lineal Only
SPC 38Lineal OnlyLineal Only
SPC 37SPC 36Lineal & Round Top
Lineal OnlySPC 40
Lineal & Round TopSPC 44
Lineal OnlySPC 45
Lineal & Round TopSPC 42
Lineal OnlySPC 43
Lineal & Round Top
Lineal OnlyLineal OnlySPC 34
Lineal OnlySPC 35SPC 33
Lineal & Round TopSPC 31
Lineal & Round TopLineal & Round TopLineal & Round TopLineal & Round TopSPC28 SPC29 SPC 30SPC 27
SPC 23Lineal Only
SPC 26SPC 25Lineal & Round Top
SPC 24Lineal & Round Top Lineal & Round Top
ACCESSORIES-8 19972255Marvin Architectural Detail Manual
Ver 2016.2 2016-04-25
Accessories
Clad Extrusion / Clad CasingNot to Scale
1 1/8"(29)
2 1/8"(54)
2 1/4"(57)
1 3/8"(35)
2 1/32"(52)
3 9/32"(84)
7/8"(22)
1 1/16"(27)
25/32"(20)
7/32"(6)
3/8"(9)
A104
A117
A1111"
(25)
A112
2"(51)
A1133"
(76)
A1144"
(101)
6"(152)
A119
1 3/8"(35)
1 3/8"(35)
13/32"(11)
Mull ExpanderA107 - 1" (25)
Mull ExpanderA108 - 2" (51)
Mull Expander 118 - 1" (25)
Frame ExpanderA110 - 2" (51)
Extender-Jamb Extension
A126
Frame ExpanderA120-90 Degree
Side TrimA148-Applied at the perimeter of the unit to enclose opening at
the space mullion
Frame ExpanderA109 - 3" (76)
Extender-Jamb Extension
A126
Mullion CapA104
Mullion CoverA117 - 13/32” (11)
Mullion Cover A111 - 1" (25)
Mullion CoverA112 - 2" (51)
Mullion CoverA116 - 6" (152)
Corner CoverA119
Mullion CoverA113 - 3" (76)
Mullion CoverA114 - 4" (102)
1 1/4"(32)
1 5/16"(33)
1 5/16"(33)
1 1/4"(32)
3"(76)
1 3/32"(28)
1 3/16"(30)
1 11/32"(34)
9/16"(14)
3/8"(9)
1 11/32"(34)
1 5/32"(29)
1 11/32"(34)
Clad Flat CasingA2754
Clad Brick Mould Casing
A898Field Applied
Only
Clad Brick Mould Casing
A797Factory Applied
Clad CasingA217
For use with clad units
Sill AdapterA129
For use withA130
Clad Casing SubsillA246
1 1/2"(38)
1 3/8"(35)
Adjustable Brick MouldA130
ACCESSORIES-9 19972255Marvin Architectural Detail Manual
Ver 2013.2 2013-09-09
Accessories
Clad Special Casing ProfilesNot to Scale
ACCESSORIES-10 19972255Marvin Architectural Detail Manual
Ver 2018.1 2018-02-26
Accessories
Clad Special Subsill ProfilesNot to Scale
NOTE: Maximum R.O. width of 144 R.O. height 96 not to exceed 80 square feet.
Not all subsills are compatible with all casings. Please refer to detail pages for compatibility.
3/8"(9)
A1450
1 25/32"(45)
SILL
25/32"(20)
4 5/32"(106)
A1451
1 19/32"(40)
SILL
4 17/32"(115)
2 5/32"(55)
1 15/16"(49)
A1452
SILL
2 19/32"(66)
A1453
1 1/4"(32)
SILL2 31/32"(75)
21/32"(17)
ACCESSORIES-11 19972255Marvin Architectural Detail Manual
Ver 2016.2 2016-04-25
Accessories
Lineal Subsill Caps / End CapsNot to Scale
Lineal Subsill Caps
Subsill End Caps
A1458 Subsill Lineal CapFor A1453
A1460 Subsill Lineal CapFor A1452
A1462 Subsill Lineal CapFor A217
A1463 Subsill Lineal CapFor A1450
Subsill End Cap for A1452 Subsill End Cap for A217
Subsill End Cap for A1453 Subsill End Cap for A1450
ACCESSORIES-12 19972255Marvin Architectural Detail Manual
Ver 2014.2 2014-10-27
Accessories
Round Top ShapesNot to Scale
NOTE: The following casings apply to the shapes shown above..
NOTE: Bows/Bays and Arch Top Doors require Architectural approval. For more information please contact your local Marvinrepresentative
Minimum Frame Radius for Round Tops:
Columbus 24" (610)
Grayson 12" (305)
Stratton, Ridgeland, Thorton 10" (254) Clad BMC 9" (229)
Potter 4 piece 9" (229) Clad Flat Casing 9" (229)
A228 Brick Mould 9" (229) Clad 1 1/2" Flat Casing 9" (229)
RT1RT2
RT6 RT7 RT8 RT9 RT10
RT21 RT22
RT27
RT17 RT18RT19 RT20 RT25 RT26
RT43 RT44 RT45 RT46
RT23 RT24
RT42
ACCESSORIES-13 19972255Marvin Architectural Detail Manual
Ver 2018.1 2018-02-26
Accessories
Clad Special Application for Windows - Casing All SidesNot to Scale
1 1/4"(32)
1 5/16"(33)
1 5/16"(33)
3"(76)
1 3/32"(28)
3"(76)
with Clad Flat CasingHead Jamb and Sill
with Clad Brick Mould CasingHead Jamb and Sill
Four SidesFour Sides
From To
in mm in mm
Masonry Opening w/BMC (all sides) Rough Opening -2 1/8 (54) -1 27/32 (47)
Masonry Opening w/Flat Casing (all sides) Rough Opening -5 1/2 (140) -5 7/32 (133)
Unit Measurment Width Height
Rough Opening
ACCESSORIES-14 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Application for Windows - Columbus Casing Stick ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1458
A1463
A1453
A1450
Applicable subsills
A1452A1460
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
Cas
ing
Out
side
Mea
sure
men
t
Casing OutsideMeasurement
RoughOpening
Frame OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
A1440 Height -1/2 Height +8 1/32 Height COM + (Sealant Gap x 1)Columbus Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +6 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 3/4 Height COM + (Sealant Gap x 1)
A1453
Measurement Conversions for Special Casing Windows
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
A1450
A1451
A1452
ACCESSORIES-15 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Application for Windows - Columbus Casing Masonry ConstructionNOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1453
A1450
A1452
Applicable subsills
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
A1452
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
A1440 Height -1/2 Height +8 1/32 Height COM + (Sealant Gap x 1)Columbus Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +6 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 3/4 Height COM + (Sealant Gap x 1)
A1453
Measurement Conversions for Special Casing Windows
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
A1450
A1451
A1452
ACCESSORIES-16 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Grayson Casing Stick ConstructionNOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1452A1460
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
Cas
ing
Out
side
Mea
sure
men
t
A1458
A1463
A1453
A1450
Applicable subsills
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 25/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
A1442 Height -1/2 Height +6 17/32 Height COM + (Sealant Gap x 1)Grayson Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +4 19/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +3 1/4 Height COM + (Sealant Gap x 1)
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
Measurement Conversions for Special Casing Windows
A1450
A1451
A1452
ACCESSORIES-17 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Grayson Casing Masonry ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1453
A1450
A1451
Applicable subsills
A1452
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
MasonryOpening
Casing OutsideMeasurement
RoughOpening
Frame OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 25/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
A1442 Height -1/2 Height +6 17/32 Height COM + (Sealant Gap x 1)Grayson Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +4 19/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +3 1/4 Height COM + (Sealant Gap x 1)
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
Measurement Conversions for Special Casing Windows
A1450
A1451
A1452
ACCESSORIES-18 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Stick ConstructionSealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
Cas
ing
Out
side
Mea
sure
men
t
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
A246
A1458
A1463
A1453
A1450
Applicable subsills
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Subsill RO to FOM FOM to COM Masonry Opening
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height + 2 1/16" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height + 2 27/32" Height COM + (sealant gap* x 2)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +2 9/32" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +6 1 32" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +4 3/32" Height COM + (sealant gap* x 2)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +2 3/4" Height COM + (sealant gap* x 2)
RO: Rough Opening
FOM: Frame Outside Measurement
COM: Casing Outside Measurement
Measurement Conversions for 1 1/2" Clad Flat Casing
1 1/2" Clad Flat Casing
A246
A217
A1450
A1451
A1452
A1453
ACCESSORIES-19 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Masonry ConstructionNot to Scale
Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1453
A1450
A1451
Applicable subsills
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
A217
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Subsill RO to FOM FOM to COM Masonry Opening
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height + 2 1/16" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height + 2 27/32" Height COM + (sealant gap* x 2)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +2 9/32" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +6 1 32" Height COM + (sealant gap* x 1)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +4 3/32" Height COM + (sealant gap* x 2)
Width -1" Width +3" Width COM + (sealant gap* x 2)
Height -1/2" Height +2 3/4" Height COM + (sealant gap* x 2)
RO: Rough Opening
FOM: Frame Outside Measurement
COM: Casing Outside Measurement
Measurement Conversions for 1 1/2" Clad Flat Casing
1 1/2" Clad Flat Casing
A246
A217
A1450
A1451
A1452
A1453
ACCESSORIES-20 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Ridgeland Casing Masonry ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurementA1453
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningA1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)
Ridgeland Height -1/2 Height +3 5/16 Height COM + (Sealant Gap x 1)
Measurement Conversions for Special Casing Windows
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
ACCESSORIES-21 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Stratton Casing MasonryNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1453
Applicable subsills
A1452
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)
A1449 Height -1/2 Height +4 21/32 Height COM + (Sealant Gap x 1)Stratton Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +3 5/16 Height COM + (Sealant Gap x 1)
Measurement Conversions for Special Casing Windows
A1452
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
ACCESSORIES-22 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Thorton Casing Masonry ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1452
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
A1453
A1450
Applicable subsills
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 15/32 Height COM + (Sealant Gap x 1)
A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Thorton Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)
Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 15/16 Height COM + (Sealant Gap x 1)
Measurement Conversions for Special Casing Windows
A1450
A1452
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
ACCESSORIES-23 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Potter Casing Wood Frame ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1462
A1460
A217
A452
A1458
A1463
A1453
A1450
Applicable Subsills
A246
Cas
ing
Out
side
Mea
sure
men
t
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
A1444/A1445 Height -1/2 Height +10 1/32 Height COM + (Sealant Gap x 1)Potter Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +8 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 3/4 Height COM + (Sealant Gap x 1)
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
Measurement Conversions for Special Casing Windows
A1450
A1451
A1452
ACCESSORIES-24 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Clad Special Casing for Windows - Potter with Trim Casing Masonry ConstructionNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A217
A1452
A1453
A1450
A1451
Applicable subsills
A246
Cas
ing
Out
side
Mea
sure
men
t
Mas
onry
Ope
ning
Fram
e O
utsi
deM
easu
rem
ent
Rou
ghO
peni
ng
MasonryOpening
RoughOpening
Frame OutsideMeasurement
Casing OutsideMeasurement
Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
A1444/A1445 Height -1/2 Height +10 1/32 Height COM + (Sealant Gap x 1)Potter w/Trim Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
Height -1/2 Height +8 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 3/4 Height COM + (Sealant Gap x 1)
A1453
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
Measurement Conversions for Special Casing Windows
A1450
A1451
A1452
ACCESSORIES-25 19972255Marvin Architectural Detail Manual
Ver 2017.1 2017-04-24
Accessories
Wood Special Casing for Windows - Special Casing 3 (SPC3)Not to Scale
WOOD SIDING W/ 2X6FRAME CONSTRUCTION
1/2(13)
1/2(13)
STUD CONSTRUCTIONBRICK VENEER W/ STEEL
Fram
eS
ize
Rou
ghO
peni
ng
1/2(12)
Mas
onry
Ope
ning
Fram
eS
ize
Rou
ghO
peni
ng
1/2(13)
1/2(13)
1/2(13)
1/4(6)
1/4(6)
1/4(6)
RoughOpeningFrameSize
RoughOpening
FrameSize
MasonryOpening
To in mm in mm
WUCA Collection Masonry Opening w/SPC3 Rough Opening -2 5/8 (67) -1 5/16 (33)
WUDHCollection Masonry Opening w/SPC3 Rough Opening -2 1/8 (54) -1 1/16 (27)
WoodDirect Glaze Masonry Opening w/SPC3 Rough Opening -2 1/2 (64) -1 1/4 (32)
WoodTilt Turn Masonry Opening w/SPC3 Rough Opening -2 1/4 (57) -1 11/16 (43)
All Doors Masonry Opening w/SPC3 Rough Opening -2 1/8 (54) -1 1/16 (27)
Width HeightUnit Measurement
From
ACCESSORIES-26 19972255Marvin Architectural Detail Manual
Ver 2016.5 2016-10-31
Accessories
Wood Special Casing for Windows - Special Casing 7 (SPC7)Not to Scale
WOOD SIDING W/ 2X6FRAME CONSTRUCTION
1/2(13)
1/2(13)
STUD CONSTRUCTIONBRICK VENEER W/ STEEL
Fram
eS
ize
Rou
ghO
peni
ng
1/2(12)
Mas
onry
Ope
ning
Fram
eS
ize
Rou
ghO
peni
ng
1/2(13)
1/4(6)
1/4(6)
1/4(6)
FrameSize
RoughOpening
MasonryOpening
1/2(13)
1/2(13)
FrameSize
RoughOpening
To in mm in mm
WUCA Collection Masonry Opening w/SPC7 Rough Opening -2 5/8 (67) -1 5/16 (33)
WUDHCollection Masonry Opening w/SPC7 Rough Opening -2 1/8 (54) -1 1/16 (27)
WoodDirect Glaze Masonry Opening w/SPC7 Rough Opening -2 1/2 (64) -1 1/4 (32)
WoodTilt Turn Masonry Opening w/SPC7 Rough Opening -2 1/4 (57) -1 11/16 (43)
All Doors Masonry Opening w/SPC7 Rough Opening -2 1/8 (54) -1 1/16 (27)
Unit Measurement Width Height
From
ACCESSORIES-27 19972255Marvin Architectural Detail Manual
Ver 2016.5 2016-10-31
Accessories
Wood Special Casing for Windows - Special Casing 21 (SPC21)Not to Scale
WOOD SIDING W/ 2X6FRAME CONSTRUCTION
1/2(13)
1/2(13)
STUD CONSTRUCTIONBRICK VENEER W/ STEEL
Fram
eS
ize
Rou
ghO
peni
ng
1/2(12)
Mas
onry
Ope
ning
Fram
eS
ize
Rou
ghO
peni
ng
1/2(13)
1/2(13)
1/2(13)
1/4(6)
1/4(6)
1/4(6)
FrameSize
RoughOpening
MasonryOpening
FrameSize
RoughOpening
To in mm in mm
WUCA Collection Masonry Opening w/SPC21 Rough Opening -2 5/8 (67) -1 5/16 (33)
WUDHCollection Masonry Opening w/SPC21 Rough Opening -2 1/8 (54) -1 1/16 (27)
WoodDirect Glaze Masonry Opening w/SPC21 Rough Opening -2 1/2 (64) -1 1/4 (32)
WoodTilt Turn Masonry Opening w/SPC21 Rough Opening -2 1/4 (57) -1 11/16 (43)
All Doors Masonry Opening w/SPC21 Rough Opening -2 1/8 (54) -1 1/16 (27)
Unit Measurement Width Height
From
ACCESSORIES-28 19972255Marvin Architectural Detail Manual
Ver 2016.5 2016-10-31
Accessories
Wood Special Casing for Windows - Special Casing 18 (SPC18)Not to Scale
WOOD SIDING W/ 2X6FRAME CONSTRUCTION
1/2(13)
1/2(13)
STUD CONSTRUCTIONBRICK VENEER W/ STEEL
Fram
eS
ize
Rou
ghO
peni
ng
1/2(12)
Mas
onry
Ope
ning
Fram
eS
ize
Rou
ghO
peni
ng
1/2(13)
1/2(13)
1/2(13)
1/4(6)
1/4(6)
1/4(6)
FrameSize
RoughOpening
FrameSize
RoughOpening
MasonryOpening
To in mm in mm
WUCA Collection Masonry Opening w/SPC18 Rough Opening -5 5/8 (143) -2 13/16 (71)
WUDHCollection Masonry Opening w/SPC18 Rough Opening -5 1/8 (130) -2 9/16 (65)
WoodDirect Glaze Masonry Opening w/SPC18 Rough Opening -5 1/2 (140) -2 3/4 (70)
WoodTilt Turn Masonry Opening w/SPC18 Rough Opening -5 1/4 (133) -3 3/16 (81)
All Doors Masonry Opening w/SPC18 Rough Opening -5 1/8 (130) -2 9/16 (65)
Unit Measurement Width Height
From
ACCESSORIES-29 19972255Marvin Architectural Detail Manual
Ver 2015.1 2015-07-09
Accessories
Wood Special Casing for Windows - Special Casing 26 (SPC26)Not to Scale
2.00000(51)
1/2(13)
1/2(13)
1/4(6)
STUD CONSTRUCTIONBRICK VENEER W/ STEEL
1/2(13)
1/2(13)
Fram
eS
ize
Rou
ghO
peni
ng
1/2(12)
WOOD SIDING W/ 2X6FRAME CONSTRUCTION 1/4
(6)Fr
ame
Siz
e
Rou
ghO
peni
ng
1/2(12)
1/4(6)
1/4(6)
Mas
onry
Ope
ning
FrameSize
RoughOpening
MasonryOpening
FrameSize
RoughOpening
To in mm in mm
WUCA Collection Masonry Opening w/SPC26 Rough Opening -2 5/8 (67) -1 5/16 (33)
WUDHCollection Masonry Opening w/SPC26 Rough Opening -2 1/8 (54) -1 1/16 (27)
WoodDirect Glaze Masonry Opening w/SPC26 Rough Opening -2 1/2 (64) -1 1/4 (32)
WoodTilt Turn Masonry Opening w/SPC26 Rough Opening -2 1/4 (57) -1 11/16 (43)
All Doors Masonry Opening w/SPC26 Rough Opening -2 1/8 (54) -1 1/16 (27)
Unit Measurement Width Height
From
ACCESSORIES-30 19972255Marvin Architectural Detail Manual
Ver 2015.1 2015-07-09
Accessories
Clad Special Casing for Doors - Wood Frame Construction - All Casings OptionsNot to Scale
NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
A1440 Columbus Casing Stick Construction
A1442 Grayson Casing A14424/1445 2 Pc. Potter Casing
Casing Type RO to FOM FOM to COM Masonry OpeningA1440 Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
Columbus Height -1/2 Height +3 1/2 Height COM + (Sealant Gap x 1)A1442 Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
Grayson Height -1/2 Height +2.0 Height COM + (Sealant Gap x 1)A1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)
Ridgeland Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1449 Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)
Stratton Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)
Thorton Height -1/2 Height +1 11/16 Height COM + (Sealant Gap x 1)A1444/A1445 Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
Potter Height -1/2 Height +5 1/2 Height COM + (Sealant Gap x 1)
Measurement Conversions for Special Casing Doors
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
ACCESSORIES-31 19972255Marvin Architectural Detail Manual
Ver 2015.1 2015-07-09
Accessories
Clad Special Casing for Doors - Masonry Construction - All Casing OptionsNot to Scale
Casing Type RO to FOM FOM to COM Masonry OpeningA1440 Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)
Columbus Height -1/2 Height +3 1/2 Height COM + (Sealant Gap x 1)A1442 Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)
Grayson Height -1/2 Height +2.0 Height COM + (Sealant Gap x 1)A1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)
Ridgeland Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1449 Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)
Stratton Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)
Thorton Height -1/2 Height +1 11/16 Height COM + (Sealant Gap x 1)A1444/A1445 Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)
Potter Height -1/2 Height +5 1/2 Height COM + (Sealant Gap x 1)
Measurement Conversions for Special Casing Doors
RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement
A14442 Grayson CasingMasonry Construction
Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended
ACCESSORIES-32 19972255Marvin Architectural Detail Manual
Accessories
Clad ApplicationsNOTE: All accessories are field applied by others, construction materials supplied by others.
A109 A126Caulking
A109 or A110
A120
A109A130
V087
A2754
V087
A898
V499
A107 or A108 A109A112
Frame Expander
A109 or A110. Used to seal the outer edge bycaulking in between the expander and the wall.Frame expander includes intermediate breakpoints to achieve additional widths.
Exterior Frame Extender
Used to extend the clad frame past the buildingsiding. Important: Caulking is required to sealbetween the frame extender and the building exterior.
Frame Expander and 90 Degree Frame Expander
A109 or A110 with A120. Used to simulate clad flatcasing in various widths.
Clad Adjustable Brick Mould Casing
Used with A109 or A110 to create an adjustable widthBrick Mould Casing for Clad units.
Clad Brick Mould Casing
Used to simulate a wood Brick Mould Casing for Clad units.
Clad Flat Casing
Used to simulate a wood casing for clad units.
Frame Expander with Mullion Expander
A109 or A110 with A107 or A108. Used to create a solidcolor matched facade between mulled clad units.
Mullion Cover
Used to create a color matched facade between mulled cladunits, available in various widths, refer to Clad Extrusions.
ACCESSORIES-33 19972255Marvin Architectural Detail Manual