i 19972255 Marvin Architectural Detail Manual Accessories Installation Bracket, Nailing Fin, Drip Cap and Jamb Extension ............................................................................ 1 Interior Trim and Interior Round Top Trim.............................................................................................................. 3 Wood Exterior Mullion Trim and Wood Exterior Casing ......................................................................................... 4 Wood Subsills......................................................................................................................................................... 5 Wood Special Profile Exterior Casings................................................................................................................... 7 Clad Extrusion / Clad Casing ................................................................................................................................. 9 Clad Special Subsill Profiles................................................................................................................................... 11 Lineal Subsill Caps / End Caps .............................................................................................................................. 12 Round Top Shapes ................................................................................................................................................ 13 Clad Special Application for Windows - Casing All Sides ...................................................................................... 14 Clad Special Application for Windows - Columbus Casing Stick Construction ...................................................... 15 Clad Special Application for Windows - Columbus Casing Masonry Construction ................................................ 16 Clad Special Casing for Windows - Grayson Casing Stick Construction ............................................................... 17 Clad Special Casing for Windows - Grayson Casing Masonry Construction ......................................................... 18 Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Stick Construction .................................................... 19 Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Masonry Construction .............................................. 20 Clad Special Casing for Windows - Ridgeland Casing Masonry Construction....................................................... 21 Clad Special Casing for Windows - Stratton Casing Masonry ............................................................................... 22 Clad Special Casing for Windows - Thorton Casing Masonry Construction .......................................................... 23 Clad Special Casing for Windows - Potter Casing Wood Frame Construction ...................................................... 24 Clad Special Casing for Windows - Potter with Trim Casing Masonry Construction.............................................. 25 Wood Special Casing for Windows - Special Casing 3 (SPC3) ............................................................................. 26 Wood Special Casing for Windows - Special Casing 7 (SPC7) ............................................................................. 27 Wood Special Casing for Windows - Special Casing 21 (SPC21) ......................................................................... 28 Wood Special Casing for Windows - Special Casing 18 (SPC18) ......................................................................... 29 Wood Special Casing for Windows - Special Casing 26 (SPC26) ......................................................................... 30 Clad Special Casing for Doors - Wood Frame Construction - All Casings Options ............................................... 31 Clad Special Casing for Doors - Masonry Construction - All Casing Options ........................................................ 32 Clad Applications.................................................................................................................................................... 33

Upload: duongkhanh

Post on 10-Jun-2018

233 views

Category:

Documents


0 download

TRANSCRIPT

AccessoriesInstallation Bracket, Nailing Fin, Drip Cap and Jamb Extension ............................................................................ 1

Interior Trim and Interior Round Top Trim.............................................................................................................. 3

Wood Exterior Mullion Trim and Wood Exterior Casing ......................................................................................... 4

Wood Subsills......................................................................................................................................................... 5

Wood Special Profile Exterior Casings................................................................................................................... 7

Clad Extrusion / Clad Casing ................................................................................................................................. 9

Clad Special Subsill Profiles................................................................................................................................... 11

Lineal Subsill Caps / End Caps.............................................................................................................................. 12

Round Top Shapes ................................................................................................................................................ 13

Clad Special Application for Windows - Casing All Sides ...................................................................................... 14

Clad Special Application for Windows - Columbus Casing Stick Construction ...................................................... 15

Clad Special Application for Windows - Columbus Casing Masonry Construction ................................................ 16

Clad Special Casing for Windows - Grayson Casing Stick Construction ............................................................... 17

Clad Special Casing for Windows - Grayson Casing Masonry Construction ......................................................... 18

Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Stick Construction .................................................... 19

Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Masonry Construction .............................................. 20

Clad Special Casing for Windows - Ridgeland Casing Masonry Construction....................................................... 21

Clad Special Casing for Windows - Stratton Casing Masonry ............................................................................... 22

Clad Special Casing for Windows - Thorton Casing Masonry Construction .......................................................... 23

Clad Special Casing for Windows - Potter Casing Wood Frame Construction ...................................................... 24

Clad Special Casing for Windows - Potter with Trim Casing Masonry Construction.............................................. 25

Wood Special Casing for Windows - Special Casing 3 (SPC3) ............................................................................. 26

Wood Special Casing for Windows - Special Casing 7 (SPC7) ............................................................................. 27

Wood Special Casing for Windows - Special Casing 21 (SPC21) ......................................................................... 28

Wood Special Casing for Windows - Special Casing 18 (SPC18) ......................................................................... 29

Wood Special Casing for Windows - Special Casing 26 (SPC26) ......................................................................... 30

Clad Special Casing for Doors - Wood Frame Construction - All Casings Options ............................................... 31

Clad Special Casing for Doors - Masonry Construction - All Casing Options ........................................................ 32

Clad Applications.................................................................................................................................................... 33

i 19972255Marvin Architectural Detail Manual

ii19972255

Marvin Architectural Detail Manual

Accessories

Installation Bracket, Nailing Fin, Drip Cap and Jamb Extension

Not to Scale

Misc1199

Misc0500

Misc076

Misc048

Installation BracketMisc. 048 - 6 3/8" (162) lengthIncludes flathead wood screws

Installation BracketMisc. 076 - 9 3/8" (238) lengthsIncludes flathead wood screws

Installation BracketMisc. 0500 - 15 3/8" (391) lengths

Includes flathead wood screws

Structural BracketMisc. 1199 - 6 3/8" (391) or 10" (254) lengths

Includes flathead wood screws

Installation Fin / Drip Cap

V084NAILING FIN

V087CONNECTING BARB

V088NAILING FIN

V104NAILING FIN HINGED VINYL NAILING FIN-SIDE

V112

HINGED VINYL NAILING FINV110

V226DRIP CAP - VINYL

- For use at Head Jamb. Optional for Wood Round Top units

- For use with Clad Round Top Units

- For use at side jambs and sill for Bow and Bay assemblies

DRIP CAP-VINYLV119

- For use at Head Jamb.For use with wood or clad unit including Brick Mould Casing.

Radius, for use at Round Top Unit

- For use at Side jambs

DRIP CAP-ALUMINUMA100

-For use at Head Jamb.For use with wood or clad unit including

Brick Mould Casing.Available in Bronze, Brown, Evergreen,

Pebble Gray and White

ACCESSORIES-1 19972255Marvin Architectural Detail Manual

Ver 2013.2 2013-08-26

Accessories

Jamb Extension

Not to Scale

1"(25)

11/16"(17)

W6120 - 1" (25)W6279 - 2’ (51)W6378 - 3" (76)

W6380 - 12" (305)

W60124 9/16" to 5 3/16"

(116 to 132)

W60114 9/16" to 5 1/16"

(116 to 129)

W60104 9/16" to 4 13/16"

(116 to 122)

11/16"(17)

5/8"(16)

11/16"(17)

1/2"(13)

11/16"(17) 1/4"

(6)

1 3/32"(28)

11/16"(17)

W2109 - 1" (25) For CUDH

1/2"(13)

2 3/32"(53)

11/16"(17)

2"(51)

W2059 - 2" (51) For CUDH

11/16"(17)

3 3/32"(79)

1/2"(13)

W1071 - 3" (76) For CUDH

1/2"(13)

4 3/32"(104)

W1069 - 4" (102) For CUDH

1/2"(13)

11/16"(17)

6 3/32"(155)

W1067 - 6" (152) For CUDH

ACCESSORIES-2 19972255Marvin Architectural Detail Manual

Ver 2012.1 2012-12-17

Accessories

Interior Trim and Interior Round Top Trim

Not to Scale

1 3/16"(30)

1/4"(6)

1/4"(6) 7/8"

(22)

1/4"(6) 7/8"

(22)1 1/16"

(27)

1/4"(6)

1 7/16"(37)

1/4"(6)

W1065 - Mullion TrimFor CUDH Vertical

W1195 - Mullion TrimFor Inswing French Door

W1241 - Mullion TrimTilt-Turn, Hopper

W1242 -Mullion Trim

Interior Trim

Interior Round Top (Available in Oak or Pine)

2 1/4"(57)

5/8"(16)

W1144 - Used as optional interior casing for RT and

Arch French Door Only

2 1/2"(63)

21/32"(17)

W1445- Used as optional interior casing for RT and

Arch French Door Only

21/32"(17)

3 1/4"(83)

W1351 - Used as optional interior casing for RT and

Arch French Door Only

21/32"(17)

2 3/16"(56)

W1366 - Used as optional interior casing for RT and

Arch French Door Only

2 1/4"(57)

21/32"(17)

W1376 - Used as optional interior casing for RT and

Arch French Door Only

ACCESSORIES-3 19972255Marvin Architectural Detail Manual

Ver 2016.5 2016-10-31

Accessories

Wood Exterior Mullion Trim and Wood Exterior Casing

Not to Scale

NOTE: 5/4 casing greater than 10", contact your Marvin representative

W1185

3/8"(10)

1 13/16"(46)

W1189

3/8"(10)

1 13/16"(46)

W1187

3/8"(10

1 13/16"(46)

W1034 - For Ultimate Gilder W1094 - For Magnum Double Hung

W1242 - for 3/8” MullionReinforcement

Wood Exterior Mullion Trim

2"(51)

1 7/32"(31)

2"(51)

1 7/32"(31)

1 3/32"(28)

3 1/2"(89)

13/16"(21)

11/16"(17)

Exterior Casing

1 7/32"(31)

2"(51)

1 7/32"(31)

2"(51)

11/16"(17)

9/32(7)

1 3/32"(28)

3 1/2"(89)

13/16"(21)

11/16"(17)

1 3/32"(28)

2 1/4"(57)

3 1/2"(89)

1 3/32"(28)

3 1/2"(89)

1 3/32"(28)

9/32"(7)

11/16"(17)

W1047 - Brick Mould Casing

W1039 - Stucco Brick Mould Casing

W1047 - Flat Casing Top casing for Sliding, Swinging and French

Doors Includes Screen Kerf

W6533 - Brick Mould Casing

For Sliding French Door

W1049 - Stucco Brick Mould CasingSide Casing for Sliding,

Swinging and French Doors

W1076 - Flat CasingSide Casing for Sliding,

Swinging and French Doors

Flat Casingavailable from 2" to 10" W1035 - Stucco Flat Casing

3 1/2” for top casingW1030 - Stucco Flat Casing

3 1/2” for side casing

ACCESSORIES-4 19972255Marvin Architectural Detail Manual

Ver 2014.1 2014-01-23

Accessories

Wood Subsills

Not to Scale

NOTE: For product compatibility, see chart on next page.

3 17/32"(90)

W8063 - 2" Simulated Thick Subsill

2 9/32"(58)

W10341 - 2" Extended Simulated Thick Subsill

1 3/32"(28)

3 17/32"(90)

2 9/32"(58)

15/16"(24)

2"(51)

2"(51)

W10340 - 2" Simulated Thick Subsill

2 3/4"(70)

2"(51)

15/16"(24)

1 13/16"(46)

2 3/4"(70)

W2165 - 2" Simulated Thick Subsill

2"(51)

1 3/32"(28)

1 13/16"(46)

2 27/32"(72)

W2122 - Narrow Subsill

1 1/4"(32)

1 1/16"(27)

1 15/32"(37)

W2124 - Cut Back Subsill

15/16"(24)

2 3/4"(70)

W2134 - Subsill

1 3/32"(28) 29/32"

(23)

2 3/4"(70)

W10333 - Subsill

15/16"(24) 3/4"

(19)

ACCESSORIES-5 19972255Marvin Architectural Detail Manual

Ver 2016.4 2016-08-29

Accessories

Wood Subsills

Not to Scale

NOTE: For product compatibility, see chart below.

3 29/32"(99)

1 3/32"(28) 3/4"

(19)

W8002 - 2 1/2" Extended Subsill

4 5/32"(106)

1 3/32"(28) 23/32"

(18)

W8003 - 2 3/4" Extended Subsill

4 29/32"(125)

W8005 - 3 1/2" Extended Subsill

1 3/32"(28) 5/8"

(16)

4 29/32"(125)

W10342 - 3 1/2" Extended Subsill

15/16"(24) 15/32"

(12)

Part # Description Product Compatibility

W8063 2" Simulated Thick Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W10341 2" Extended Simulated Thick Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA

W10340 2" Simulated Thick Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA

W2165 2" Simulated Thick Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W2122 Narrow Subsill WMTT

W2124 Cut Back Subsill WMTT

W2134 Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W10333 Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA

W2120 Extended Subsill WMTT

W8002 2 1/2" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W8003 2 3/4" Extended Sudsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W8004 3" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W8005 3 1/2" Extended Subsill WUDH, WUDHP, WUDHT, WUDH RT, WUDHRTP, WUDHRTT, WUDHM, WUDHMP, WUDHMT, WUDHMRT, UDHMRTP, WUDHMRTT

W10342 3 1/2" Extended Subsill WUCA, WUAWN, WUCAP, WUPCA, WUPAWN, WUPCAP, WUCART, WDG, WUGL, WUCAPOLY, WUFCA, WUPFCA

ACCESSORIES-6 19972255Marvin Architectural Detail Manual

Ver 2016.4 2016-08-29

Accessories

Wood Special Profile Exterior Casings

These sections illustrate the profile of each special casing and their dimensions. Each casing is labeled with its availability for linealand/or round top units. Not all casings are applicable and varying conditions may require consideration for units including screens,combinations, mullions, etc. and may require extended sills. Illustrations shown are not to scale.

3 11/32"(85)

1 13/16"(46)

1 1/4"(32)

2"(51)

2"(51)

3 1/4"(83)

2"(51)

2"(51)

11/16"(17)

1 1/4"(32)

11/16"(17)

2"(51)

1 1/16"(27)

3 1/2"(89)2 7/8"

(73)

1 7/32"(31) 1 1/4"

(32)

3 1/2"(89)

1 1/2"(38)

2"(51)

2 1/2"(63)

1 1/4"(32)

2"(51)

2"(51)

1 1/4"(32)

1 1/4"(32)

2"(51)

1 1/2"(38)

1 3/16"(30)

1 3/4"(44)

1 3/4"(44)

1 1/4"(32)

2 1/16"(52)

2"(51)

9/16"(14)

1 3/16"(31) 1 1/16"

(27)

1 3/4"(44)

11/16"(17)

1 1/4"(32)

1 7/8"(48)

3/4"(19)

Lineal & Round TopSPC 21

SPC 16SPC 15

Lineal & Round TopSPC 20

Lineal & Round TopSPC 19

Lineal OnlySPC 22

Lineal & Round TopSPC 18SPC 17

Lineal Only

SPC 14Lineal & Round Top

SPC 13Lineal & Round Top

Lineal & Round TopSPC 10

SPC 6Lineal & Round Top

SPC 2Lineal & Round Top

SPC 1Lineal Only Lineal & Round TopLineal & Round Top

Lineal & Round TopLineal OnlySPC 7

Lineal & Round TopSPC 8

SPC 4SPC 3

SPC 5

Lineal & Round TopSPC 9

Lineal OnlyLineal Only

SPC 12Lineal & Round TopLineal Only

SPC 11

1 1/16"(27)

1 1/4"(32)

ACCESSORIES-7 19972255Marvin Architectural Detail Manual

Ver 2015.1 2015-07-09

Accessories

Wood Special Profile Exterior Casings

Not to Scale

NOTE: Please contact your Marvin representative for specific information and requirements of special casing.

2"(51)

1 3/32"(28)

2"(51)

1 1/4"(32)

1 3/4"(44)

1 3/4"(44)

1 3/4"(44)

1 7/8"(48)

2 5/8"(67)

2 1/2"(64) 1 3/8"

(35)

1 3/4"(44)

2 1/2"(64)

11/16"(17)

1 3/8"(35)

1 3/4"(44)

1 11/16"(43)

2"(51)

1 11/16"(43)

1 5/16"(33)

1 1/2"(38)

1 1/4"(32)

1 5/8"(41)

1 1/4"(32)

1 1/4"(32)

2 1/2"(64)

1 5/8"(41)

1 7/16"(37)

2 9/16"(65)

1 1/2"(38)

2 5/8"(67)

3 1/2"(89)

1 3/32"(28)

5"(127)1 21/32"

(42)

1 5/32"(29)

2"(51)

2"(51)

4"(102)

1 3/32"(28) 1 7/8"

(48)

1 3/4"(44)

1 9/16"(40)

1"(25)

SPC 41

SPC 39Lineal Only

SPC 38Lineal OnlyLineal Only

SPC 37SPC 36Lineal & Round Top

Lineal OnlySPC 40

Lineal & Round TopSPC 44

Lineal OnlySPC 45

Lineal & Round TopSPC 42

Lineal OnlySPC 43

Lineal & Round Top

Lineal OnlyLineal OnlySPC 34

Lineal OnlySPC 35SPC 33

Lineal & Round TopSPC 31

Lineal & Round TopLineal & Round TopLineal & Round TopLineal & Round TopSPC28 SPC29 SPC 30SPC 27

SPC 23Lineal Only

SPC 26SPC 25Lineal & Round Top

SPC 24Lineal & Round Top Lineal & Round Top

ACCESSORIES-8 19972255Marvin Architectural Detail Manual

Ver 2016.2 2016-04-25

Accessories

Clad Extrusion / Clad Casing

Not to Scale

1 1/8"(29)

2 1/8"(54)

2 1/4"(57)

1 3/8"(35)

2 1/32"(52)

3 9/32"(84)

7/8"(22)

1 1/16"(27)

25/32"(20)

7/32"(6)

3/8"(9)

A104

A117

A1111"

(25)

A112

2"(51)

A1133"

(76)

A1144"

(101)

6"(152)

A119

1 3/8"(35)

1 3/8"(35)

13/32"(11)

Mull ExpanderA107 - 1" (25)

Mull ExpanderA108 - 2" (51)

Mull Expander 118 - 1" (25)

Frame ExpanderA110 - 2" (51)

Extender-Jamb Extension

A126

Frame ExpanderA120-90 Degree

Side TrimA148-Applied at the perimeter of the unit to enclose opening at

the space mullion

Frame ExpanderA109 - 3" (76)

Extender-Jamb Extension

A126

Mullion CapA104

Mullion CoverA117 - 13/32” (11)

Mullion Cover A111 - 1" (25)

Mullion CoverA112 - 2" (51)

Mullion CoverA116 - 6" (152)

Corner CoverA119

Mullion CoverA113 - 3" (76)

Mullion CoverA114 - 4" (102)

1 1/4"(32)

1 5/16"(33)

1 5/16"(33)

1 1/4"(32)

3"(76)

1 3/32"(28)

1 3/16"(30)

1 11/32"(34)

9/16"(14)

3/8"(9)

1 11/32"(34)

1 5/32"(29)

1 11/32"(34)

Clad Flat CasingA2754

Clad Brick Mould Casing

A898Field Applied

Only

Clad Brick Mould Casing

A797Factory Applied

Clad CasingA217

For use with clad units

Sill AdapterA129

For use withA130

Clad Casing SubsillA246

1 1/2"(38)

1 3/8"(35)

Adjustable Brick MouldA130

ACCESSORIES-9 19972255Marvin Architectural Detail Manual

Ver 2013.2 2013-09-09

Accessories

Clad Special Casing Profiles

Not to Scale

ACCESSORIES-10 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Accessories

Clad Special Subsill Profiles

Not to Scale

NOTE: Maximum R.O. width of 144 R.O. height 96 not to exceed 80 square feet.

Not all subsills are compatible with all casings. Please refer to detail pages for compatibility.

3/8"(9)

A1450

1 25/32"(45)

SILL

25/32"(20)

4 5/32"(106)

A1451

1 19/32"(40)

SILL

4 17/32"(115)

2 5/32"(55)

1 15/16"(49)

A1452

SILL

2 19/32"(66)

A1453

1 1/4"(32)

SILL2 31/32"(75)

21/32"(17)

ACCESSORIES-11 19972255Marvin Architectural Detail Manual

Ver 2016.2 2016-04-25

Accessories

Lineal Subsill Caps / End Caps

Not to Scale

Lineal Subsill Caps

Subsill End Caps

A1458 Subsill Lineal CapFor A1453

A1460 Subsill Lineal CapFor A1452

A1462 Subsill Lineal CapFor A217

A1463 Subsill Lineal CapFor A1450

Subsill End Cap for A1452 Subsill End Cap for A217

Subsill End Cap for A1453 Subsill End Cap for A1450

ACCESSORIES-12 19972255Marvin Architectural Detail Manual

Ver 2014.2 2014-10-27

Accessories

Round Top Shapes

Not to Scale

NOTE: The following casings apply to the shapes shown above..

NOTE: Bows/Bays and Arch Top Doors require Architectural approval. For more information please contact your local Marvinrepresentative

Minimum Frame Radius for Round Tops:

Columbus 24" (610)

Grayson 12" (305)

Stratton, Ridgeland, Thorton 10" (254) Clad BMC 9" (229)

Potter 4 piece 9" (229) Clad Flat Casing 9" (229)

A228 Brick Mould 9" (229) Clad 1 1/2" Flat Casing 9" (229)

RT1RT2

RT6 RT7 RT8 RT9 RT10

RT21 RT22

RT27

RT17 RT18RT19 RT20 RT25 RT26

RT43 RT44 RT45 RT46

RT23 RT24

RT42

ACCESSORIES-13 19972255Marvin Architectural Detail Manual

Ver 2018.1 2018-02-26

Accessories

Clad Special Application for Windows - Casing All Sides

Not to Scale

1 1/4"(32)

1 5/16"(33)

1 5/16"(33)

3"(76)

1 3/32"(28)

3"(76)

with Clad Flat CasingHead Jamb and Sill

with Clad Brick Mould CasingHead Jamb and Sill

Four SidesFour Sides

From To

in mm in mm

Masonry Opening w/BMC (all sides) Rough Opening -2 1/8 (54) -1 27/32 (47)

Masonry Opening w/Flat Casing (all sides) Rough Opening -5 1/2 (140) -5 7/32 (133)

Unit Measurment Width Height

Rough Opening

ACCESSORIES-14 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Application for Windows - Columbus Casing Stick Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1458

A1463

A1453

A1450

Applicable subsills

A1452A1460

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

Cas

ing

Out

side

Mea

sure

men

t

Casing OutsideMeasurement

RoughOpening

Frame OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

A1440 Height -1/2 Height +8 1/32 Height COM + (Sealant Gap x 1)Columbus Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +6 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 3/4 Height COM + (Sealant Gap x 1)

A1453

Measurement Conversions for Special Casing Windows

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

A1450

A1451

A1452

ACCESSORIES-15 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Application for Windows - Columbus Casing Masonry Construction

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1453

A1450

A1452

Applicable subsills

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

A1452

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

A1440 Height -1/2 Height +8 1/32 Height COM + (Sealant Gap x 1)Columbus Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +6 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +4 3/4 Height COM + (Sealant Gap x 1)

A1453

Measurement Conversions for Special Casing Windows

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

A1450

A1451

A1452

ACCESSORIES-16 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Grayson Casing Stick Construction

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1452A1460

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

Cas

ing

Out

side

Mea

sure

men

t

A1458

A1463

A1453

A1450

Applicable subsills

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 25/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

A1442 Height -1/2 Height +6 17/32 Height COM + (Sealant Gap x 1)Grayson Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +4 19/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +3 1/4 Height COM + (Sealant Gap x 1)

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

Measurement Conversions for Special Casing Windows

A1450

A1451

A1452

ACCESSORIES-17 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Grayson Casing Masonry Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1453

A1450

A1451

Applicable subsills

A1452

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

MasonryOpening

Casing OutsideMeasurement

RoughOpening

Frame OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 25/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

A1442 Height -1/2 Height +6 17/32 Height COM + (Sealant Gap x 1)Grayson Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +4 19/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +3 1/4 Height COM + (Sealant Gap x 1)

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

Measurement Conversions for Special Casing Windows

A1450

A1451

A1452

ACCESSORIES-18 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Stick Construction

Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

Cas

ing

Out

side

Mea

sure

men

t

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

A246

A1458

A1463

A1453

A1450

Applicable subsills

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Subsill RO to FOM FOM to COM Masonry Opening

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height + 2 1/16" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height + 2 27/32" Height COM + (sealant gap* x 2)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +2 9/32" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +6 1 32" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +4 3/32" Height COM + (sealant gap* x 2)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +2 3/4" Height COM + (sealant gap* x 2)

RO: Rough Opening

FOM: Frame Outside Measurement

COM: Casing Outside Measurement

Measurement Conversions for 1 1/2" Clad Flat Casing

1 1/2" Clad Flat Casing

A246

A217

A1450

A1451

A1452

A1453

ACCESSORIES-19 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - 1 1/2" Clad Flat Casing Masonry Construction

Not to Scale

Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1453

A1450

A1451

Applicable subsills

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

A217

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Subsill RO to FOM FOM to COM Masonry Opening

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height + 2 1/16" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height + 2 27/32" Height COM + (sealant gap* x 2)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +2 9/32" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +6 1 32" Height COM + (sealant gap* x 1)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +4 3/32" Height COM + (sealant gap* x 2)

Width -1" Width +3" Width COM + (sealant gap* x 2)

Height -1/2" Height +2 3/4" Height COM + (sealant gap* x 2)

RO: Rough Opening

FOM: Frame Outside Measurement

COM: Casing Outside Measurement

Measurement Conversions for 1 1/2" Clad Flat Casing

1 1/2" Clad Flat Casing

A246

A217

A1450

A1451

A1452

A1453

ACCESSORIES-20 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Ridgeland Casing Masonry Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurementA1453

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningA1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)

Ridgeland Height -1/2 Height +3 5/16 Height COM + (Sealant Gap x 1)

Measurement Conversions for Special Casing Windows

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

ACCESSORIES-21 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Stratton Casing Masonry

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1453

Applicable subsills

A1452

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)

A1449 Height -1/2 Height +4 21/32 Height COM + (Sealant Gap x 1)Stratton Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +3 5/16 Height COM + (Sealant Gap x 1)

Measurement Conversions for Special Casing Windows

A1452

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

ACCESSORIES-22 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Thorton Casing Masonry Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1452

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

A1453

A1450

Applicable subsills

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 15/32 Height COM + (Sealant Gap x 1)

A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Thorton Height -1/2 Height +4 9/32 Height COM + (Sealant Gap x 1)

Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)Height -1/2 Height +2 15/16 Height COM + (Sealant Gap x 1)

Measurement Conversions for Special Casing Windows

A1450

A1452

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

ACCESSORIES-23 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Potter Casing Wood Frame Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1462

A1460

A217

A452

A1458

A1463

A1453

A1450

Applicable Subsills

A246

Cas

ing

Out

side

Mea

sure

men

t

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

A1444/A1445 Height -1/2 Height +10 1/32 Height COM + (Sealant Gap x 1)Potter Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +8 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 3/4 Height COM + (Sealant Gap x 1)

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

Measurement Conversions for Special Casing Windows

A1450

A1451

A1452

ACCESSORIES-24 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Clad Special Casing for Windows - Potter with Trim Casing Masonry Construction

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A217

A1452

A1453

A1450

A1451

Applicable subsills

A246

Cas

ing

Out

side

Mea

sure

men

t

Mas

onry

Ope

ning

Fram

e O

utsi

deM

easu

rem

ent

Rou

ghO

peni

ng

MasonryOpening

RoughOpening

Frame OutsideMeasurement

Casing OutsideMeasurement

Casing Type Subsill Type RO to FOM FOM to COM Masonry OpeningWidth -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 9/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

A1444/A1445 Height -1/2 Height +10 1/32 Height COM + (Sealant Gap x 1)Potter w/Trim Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

Height -1/2 Height +8 3/32 Height COM + (Sealant Gap x 1)Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)Height -1/2 Height +6 3/4 Height COM + (Sealant Gap x 1)

A1453

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

Measurement Conversions for Special Casing Windows

A1450

A1451

A1452

ACCESSORIES-25 19972255Marvin Architectural Detail Manual

Ver 2017.1 2017-04-24

Accessories

Wood Special Casing for Windows - Special Casing 3 (SPC3)

Not to Scale

WOOD SIDING W/ 2X6FRAME CONSTRUCTION

1/2(13)

1/2(13)

STUD CONSTRUCTIONBRICK VENEER W/ STEEL

Fram

eS

ize

Rou

ghO

peni

ng

1/2(12)

Mas

onry

Ope

ning

Fram

eS

ize

Rou

ghO

peni

ng

1/2(13)

1/2(13)

1/2(13)

1/4(6)

1/4(6)

1/4(6)

RoughOpeningFrameSize

RoughOpening

FrameSize

MasonryOpening

To in mm in mm

WUCA Collection Masonry Opening w/SPC3 Rough Opening -2 5/8 (67) -1 5/16 (33)

WUDHCollection Masonry Opening w/SPC3 Rough Opening -2 1/8 (54) -1 1/16 (27)

WoodDirect Glaze Masonry Opening w/SPC3 Rough Opening -2 1/2 (64) -1 1/4 (32)

WoodTilt Turn Masonry Opening w/SPC3 Rough Opening -2 1/4 (57) -1 11/16 (43)

All Doors Masonry Opening w/SPC3 Rough Opening -2 1/8 (54) -1 1/16 (27)

Width HeightUnit Measurement

From

ACCESSORIES-26 19972255Marvin Architectural Detail Manual

Ver 2016.5 2016-10-31

Accessories

Wood Special Casing for Windows - Special Casing 7 (SPC7)

Not to Scale

WOOD SIDING W/ 2X6FRAME CONSTRUCTION

1/2(13)

1/2(13)

STUD CONSTRUCTIONBRICK VENEER W/ STEEL

Fram

eS

ize

Rou

ghO

peni

ng

1/2(12)

Mas

onry

Ope

ning

Fram

eS

ize

Rou

ghO

peni

ng

1/2(13)

1/4(6)

1/4(6)

1/4(6)

FrameSize

RoughOpening

MasonryOpening

1/2(13)

1/2(13)

FrameSize

RoughOpening

To in mm in mm

WUCA Collection Masonry Opening w/SPC7 Rough Opening -2 5/8 (67) -1 5/16 (33)

WUDHCollection Masonry Opening w/SPC7 Rough Opening -2 1/8 (54) -1 1/16 (27)

WoodDirect Glaze Masonry Opening w/SPC7 Rough Opening -2 1/2 (64) -1 1/4 (32)

WoodTilt Turn Masonry Opening w/SPC7 Rough Opening -2 1/4 (57) -1 11/16 (43)

All Doors Masonry Opening w/SPC7 Rough Opening -2 1/8 (54) -1 1/16 (27)

Unit Measurement Width Height

From

ACCESSORIES-27 19972255Marvin Architectural Detail Manual

Ver 2016.5 2016-10-31

Accessories

Wood Special Casing for Windows - Special Casing 21 (SPC21)

Not to Scale

WOOD SIDING W/ 2X6FRAME CONSTRUCTION

1/2(13)

1/2(13)

STUD CONSTRUCTIONBRICK VENEER W/ STEEL

Fram

eS

ize

Rou

ghO

peni

ng

1/2(12)

Mas

onry

Ope

ning

Fram

eS

ize

Rou

ghO

peni

ng

1/2(13)

1/2(13)

1/2(13)

1/4(6)

1/4(6)

1/4(6)

FrameSize

RoughOpening

MasonryOpening

FrameSize

RoughOpening

To in mm in mm

WUCA Collection Masonry Opening w/SPC21 Rough Opening -2 5/8 (67) -1 5/16 (33)

WUDHCollection Masonry Opening w/SPC21 Rough Opening -2 1/8 (54) -1 1/16 (27)

WoodDirect Glaze Masonry Opening w/SPC21 Rough Opening -2 1/2 (64) -1 1/4 (32)

WoodTilt Turn Masonry Opening w/SPC21 Rough Opening -2 1/4 (57) -1 11/16 (43)

All Doors Masonry Opening w/SPC21 Rough Opening -2 1/8 (54) -1 1/16 (27)

Unit Measurement Width Height

From

ACCESSORIES-28 19972255Marvin Architectural Detail Manual

Ver 2016.5 2016-10-31

Accessories

Wood Special Casing for Windows - Special Casing 18 (SPC18)

Not to Scale

WOOD SIDING W/ 2X6FRAME CONSTRUCTION

1/2(13)

1/2(13)

STUD CONSTRUCTIONBRICK VENEER W/ STEEL

Fram

eS

ize

Rou

ghO

peni

ng

1/2(12)

Mas

onry

Ope

ning

Fram

eS

ize

Rou

ghO

peni

ng

1/2(13)

1/2(13)

1/2(13)

1/4(6)

1/4(6)

1/4(6)

FrameSize

RoughOpening

FrameSize

RoughOpening

MasonryOpening

To in mm in mm

WUCA Collection Masonry Opening w/SPC18 Rough Opening -5 5/8 (143) -2 13/16 (71)

WUDHCollection Masonry Opening w/SPC18 Rough Opening -5 1/8 (130) -2 9/16 (65)

WoodDirect Glaze Masonry Opening w/SPC18 Rough Opening -5 1/2 (140) -2 3/4 (70)

WoodTilt Turn Masonry Opening w/SPC18 Rough Opening -5 1/4 (133) -3 3/16 (81)

All Doors Masonry Opening w/SPC18 Rough Opening -5 1/8 (130) -2 9/16 (65)

Unit Measurement Width Height

From

ACCESSORIES-29 19972255Marvin Architectural Detail Manual

Ver 2015.1 2015-07-09

Accessories

Wood Special Casing for Windows - Special Casing 26 (SPC26)

Not to Scale

2.00000(51)

1/2(13)

1/2(13)

1/4(6)

STUD CONSTRUCTIONBRICK VENEER W/ STEEL

1/2(13)

1/2(13)

Fram

eS

ize

Rou

ghO

peni

ng

1/2(12)

WOOD SIDING W/ 2X6FRAME CONSTRUCTION 1/4

(6)Fr

ame

Siz

e

Rou

ghO

peni

ng

1/2(12)

1/4(6)

1/4(6)

Mas

onry

Ope

ning

FrameSize

RoughOpening

MasonryOpening

FrameSize

RoughOpening

To in mm in mm

WUCA Collection Masonry Opening w/SPC26 Rough Opening -2 5/8 (67) -1 5/16 (33)

WUDHCollection Masonry Opening w/SPC26 Rough Opening -2 1/8 (54) -1 1/16 (27)

WoodDirect Glaze Masonry Opening w/SPC26 Rough Opening -2 1/2 (64) -1 1/4 (32)

WoodTilt Turn Masonry Opening w/SPC26 Rough Opening -2 1/4 (57) -1 11/16 (43)

All Doors Masonry Opening w/SPC26 Rough Opening -2 1/8 (54) -1 1/16 (27)

Unit Measurement Width Height

From

ACCESSORIES-30 19972255Marvin Architectural Detail Manual

Ver 2015.1 2015-07-09

Accessories

Clad Special Casing for Doors - Wood Frame Construction - All Casings Options

Not to Scale

NOTE: Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

A1440 Columbus Casing Stick Construction

A1442 Grayson Casing A14424/1445 2 Pc. Potter Casing

Casing Type RO to FOM FOM to COM Masonry OpeningA1440 Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

Columbus Height -1/2 Height +3 1/2 Height COM + (Sealant Gap x 1)A1442 Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

Grayson Height -1/2 Height +2.0 Height COM + (Sealant Gap x 1)A1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)

Ridgeland Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1449 Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)

Stratton Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)

Thorton Height -1/2 Height +1 11/16 Height COM + (Sealant Gap x 1)A1444/A1445 Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

Potter Height -1/2 Height +5 1/2 Height COM + (Sealant Gap x 1)

Measurement Conversions for Special Casing Doors

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

ACCESSORIES-31 19972255Marvin Architectural Detail Manual

Ver 2015.1 2015-07-09

Accessories

Clad Special Casing for Doors - Masonry Construction - All Casing Options

Not to Scale

Casing Type RO to FOM FOM to COM Masonry OpeningA1440 Width -1.0 Width +7.0 *Width COM + (Sealant Gap x 2)

Columbus Height -1/2 Height +3 1/2 Height COM + (Sealant Gap x 1)A1442 Width -1.0 Width +4.0 *Width COM + (Sealant Gap x 2)

Grayson Height -1/2 Height +2.0 Height COM + (Sealant Gap x 1)A1446 Width -1.0 Width +4 1/8 *Width COM + (Sealant Gap x 2)

Ridgeland Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1449 Width -1.0 Width +4 5/32 *Width COM + (Sealant Gap x 2)

Stratton Height -1/2 Height +2 1/16 Height COM + (Sealant Gap x 1)A1443 Width -1.0 Width +3 13/32 *Width COM + (Sealant Gap x 2)

Thorton Height -1/2 Height +1 11/16 Height COM + (Sealant Gap x 1)A1444/A1445 Width -1.0 Width +6.0 *Width COM + (Sealant Gap x 2)

Potter Height -1/2 Height +5 1/2 Height COM + (Sealant Gap x 1)

Measurement Conversions for Special Casing Doors

RO: Rough OpeningFOM: Frame Outside MeasurementCOM: Casing Outside Measurement

A14442 Grayson CasingMasonry Construction

Sealant gap to be determined by others. Minimum of 1/4" on all four sides recommended

ACCESSORIES-32 19972255Marvin Architectural Detail Manual

Accessories

Clad Applications

NOTE: All accessories are field applied by others, construction materials supplied by others.

A109 A126Caulking

A109 or A110

A120

A109A130

V087

A2754

V087

A898

V499

A107 or A108 A109A112

Frame Expander

A109 or A110. Used to seal the outer edge bycaulking in between the expander and the wall.Frame expander includes intermediate breakpoints to achieve additional widths.

Exterior Frame Extender

Used to extend the clad frame past the buildingsiding. Important: Caulking is required to sealbetween the frame extender and the building exterior.

Frame Expander and 90 Degree Frame Expander

A109 or A110 with A120. Used to simulate clad flatcasing in various widths.

Clad Adjustable Brick Mould Casing

Used with A109 or A110 to create an adjustable widthBrick Mould Casing for Clad units.

Clad Brick Mould Casing

Used to simulate a wood Brick Mould Casing for Clad units.

Clad Flat Casing

Used to simulate a wood casing for clad units.

Frame Expander with Mullion Expander

A109 or A110 with A107 or A108. Used to create a solidcolor matched facade between mulled clad units.

Mullion Cover

Used to create a color matched facade between mulled cladunits, available in various widths, refer to Clad Extrusions.

ACCESSORIES-33 19972255Marvin Architectural Detail Manual