accident is painful personal protective equipment (ppe ... fire safety equipments 35/13, sivam...

2
Somya Pyrotek Services AN ISO 9001-2008 CERTIFIED COMPANY Marketing Division : IS : 15683 CM/L : 2529155 CE BHARATH FIRE SAFETY EQUIPMENTS BHARATH FIRE SAFETY EQUIPMENTS 35/13, Sivam Complex, 1st Floor, Corporation Colony Road, Opp. Water Tank, Arapalayam Main Road, Madurai - 625 016. Cell : 99409 63801 97873 96962 E-mail [email protected] F E A T S Y E E R Q I U F I P H M T A E R N A T H S B BFSE Safety is Gainful NOT JUST EXTINGUISHERS WE CREATE WISHERS FIRE FIRE EXTINCT Accident is Painful Personal Protective Equipment (PPE Products) Safety Helmet Safety Eye Glass Face Mask (Chemical, Dust, Disposable) Ear Muff Ear Plug Apron (PVC & Leather) Hand Gloves (Disposable Cotton, Chemical {Half & Full Sleeve}, Leather, Metal Safety Shoes Gumboot Electrical Gloves Electrical Rubber Mat Electrical Shoes Chemical Mat Rubber Mat (Checking, Cutting & Ironinh Safety Rope Eye Wash Emergency Shower & Fountain Eye Wash Bottle Sign Boards Yellow Marking First Aid Box Suggestion Box Fire Siren Manual Call Point Smoke Detection System Burgler Alarm Safety Cone Plastic Chain Fire Bucket with Stand Emergency Light Respiratory Mask Work Wear Welder Safety Equipment Exit LED Lamp (Inbuilt Battery) & Other Industrial Safety Products Other Industrial Requirements E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E E BHARATH FIRE SAFETY EQUIPMENTS 35/13, Sivam Complex, 1st Floor, Corporation Colony Road, Opp. Water Tank, Arapalayam Main Road, Madurai - 625 016. Cell : 99409 63801, 97873 96962 E-mail : [email protected] F E A T S Y E E R Q I U F I P H M T A E R N A T H S B BFSE Marketing Division : 2 Kg. 4 Kg. 9 Kg. 6 Kg. HOSE REELS AND DRUM

Upload: trantu

Post on 23-May-2018

214 views

Category:

Documents


1 download

TRANSCRIPT

Somya Pyrotek Services

AN ISO 9001-2008 CERTIFIED COMPANY

Marketing Division :

IS : 15683

CM/L : 2529155

CE

BHARATHFIRE SAFETYEQUIPMENTS

BHARATHFIRE SAFETY EQUIPMENTS

35/13, Sivam Complex, 1st Floor,

Corporation Colony Road, Opp. Water Tank,

Arapalayam Main Road, Madurai - 625 016.

Cell : 99409 63801

97873 96962

E-mail

[email protected]

FEA TS Y E ER QI

UF IPH

MTA E

R N

A T

H S

B BFSE

Safety is Gainful

NOT JUST EXTINGUISHERSWE CREATE WISHERS

FIRE FIRE EXTINCT

Accident is PainfulPersonal Protective Equipment (PPE Products)

Safety Helmet

Safety Eye Glass

Face Mask (Chemical, Dust, Disposable)

Ear Muff

Ear Plug

Apron (PVC & Leather)

Hand Gloves (Disposable Cotton, Chemical

{Half & Full Sleeve}, Leather, Metal

Safety Shoes

Gumboot

Electrical Gloves

Electrical Rubber Mat

Electrical Shoes

Chemical Mat

Rubber Mat (Checking, Cutting & Ironinh

Safety Rope

Eye Wash Emergency Shower & Fountain

Eye Wash Bottle

Sign Boards

Yellow Marking

First Aid Box

Suggestion Box

Fire Siren

Manual Call Point

Smoke Detection System

Burgler Alarm

Safety Cone

Plastic Chain

Fire Bucket with Stand

Emergency Light

Respiratory Mask

Work Wear

Welder Safety Equipment

Exit LED Lamp (Inbuilt Battery) &

Other Industrial Safety Products

Other Industrial Requirements

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

BHARATHFIRE SAFETY EQUIPMENTS

35/13, Sivam Complex, 1st Floor,

Corporation Colony Road,

Opp. Water Tank, Arapalayam Main Road,

Madurai - 625 016.

Cell : 99409 63801, 97873 96962

E-mail : [email protected]

FEA TS Y E ER QI

UF IPH

MTA E

R N

A T

H S

B BFSE

Marketing Division :

2 Kg. 4 Kg.

9 Kg.6 Kg.

HOSE REELS AND DRUM

Fires are Categorized into Different Classes :

Fires are categorised into different classes with a differentextinguisher type fight each type of fire. An untrained person isexpected to look at the fire, evaluate its class, decide on theappropriate fire fighting equipment and then proceed to fightthe fire. At the time of crisis this can cause confusion wastetime and be extremely dangerous. If a class A extinguisher,which is water based is used on an electrical fire, if can lead toinstant electrocution, if a class A extinguisher is used on anoil/petrol based fire, the oil will float on the water and the fireinstantly spread. If a class B/C extinguisher is used on a classa fire, it will have no effect whatsoever.

Wood, PaperFurnished etc.

Oil, Kerosene, PetrolPaint etc.

A

B

CFlammable Gases,& Electrically Started Firesetc.

The Fire Escort ABC extinguisher actively works onall classes of fire.

Fire Escort stored pressure type fire extinguisher areextremely versatile, they will tackle the majority offire risks found in most commercial industrial anddomestic environments.

Product Specifications

Can Construction

Capacity (kg).

Automatic Activation Temperature (Centigrade)

Maximum Volume Protected (in Cubic 0Feet)

Height (mm)

DIA (mm)

Gross Weight (kg.)

Test Pressure (kg/cm2)

Super Charge Pressure (kg/cm2)

Discharge Time (Seconds)

Mildsteel

5

57/68

324

230

230

8

30

15

8

Mildsteel

10

57/68

648

260

300

15

30

15

10

Mildsteel

15

57/68

1072

260

400

22

30

15

12

Extinguishing Agents / Contents ABC Dry Powder

Modular (Automatic)Type Fire Extinguishers

Design and Specification any charge without prior notice in view of technical up gradation.

OPERATION :

FIRE ESCORT (fire extinguisher) is designed to be operative,automatically. The unit is a stored pressure type with a mixture of ABC dry powder and dry nitrogen. As soon as the fire reaches the specified temperature under it, the glass bulb shatters allowing the content to be releases as mist to cover a wide area.

The fire escort fire extinguisher comes witha 5-year warranty!

OTHER FEATURES

TECHNICAL SPECIFICATIONS

Fire Escort has an active shelf life for 5 years.Thus it is a sound investment in fire safety.

Epoxy coated steel cylinder to resist corrosion, dents

punctures.

Chrome plated brass valve.

Its design make it the finest available anywhere.

Extinguisher confirms to IS : 13849

=

=

=

=

ABC FIRE EXTINGUISHERMODEL

Capacity

Anti-Corrosive Inhibitor

Conforming Is Code

Type of Extinguisher

Type of Extinguishing Media

Expellant

Minimum Effective Discharge (%)

Minimum Jet Lenth (mtrs.)

Discharge Time (Sec)

Hydraulic Tset Pressure (kgf/Cm2)

Operating Position

Charged pressure (Kgs/Cm2)

Operating Temperature Range (C)

Operating Value

Fire Rating

FA-2

2

15683 15683

Constant Stored Pressure Constant Stored Pressure

Dry Powder IS 14609 Dry Powder IS 14609

Pressurized With N2 Gas Pressurized With N2 Gas

85 85

More than 2 mtrs. More than 2 mtrs.

More than 8 Sec. More than 8 Sec.

35 35

Upright Upright

16 16

0 to + 55 0 to + 55

Epoxy PolyesterPowder Coting

Squeeze Grip Typewith Nozzle

Squeeze Grip Typewith Nozzle

1A & 88

FA-4

4

Epoxy PolyesterPowder Coting

2A & 88

15683

Constant Stored Pressure

Dry Powder IS 14609

Pressurized With N2 Gas

85

More than 2 mtrs.

More than 8 Sec.

35

Upright

16

0 to + 55

Squeeze Grip Typewith Nozzle

FA-6

6

Epoxy PolyesterPowder Coting

3A & 21B

15683

Constant Stored Pressure

Dry Powder IS 14609

Pressurized With N2 Gas

85

More than 2 mtrs.

More than 8 Sec.

35

Upright

16

0 to + 55

Squeeze Grip Typewith Nozzle

FA-9

9

Epoxy PolyesterPowder Coting

4A & 34B

RANR TA Y

W 5

CARBON DIOXIDE FIRE EXTINGUISHERCo2 EXTINGUISHERS :

Squeeze Grip avaliable in

Effective against

:

:

2 Kg and 4.5 kg

B and C fires.

The revolutionary new squeeze grip activation, removes all risk of freeze burn, and ensures that the user can rapidly put the extinguisher to use against a fire. Fire Escort CO'2s ergonomically designed handle makes it remarkably easy to carry. Fire Escort's CO2 Aluminium is lighter and more portable to use. The cylinders are made from the extrusion method, leaving no room for leakage or tempering.

CO2 FIRE EXTINGUISHERS

MODEL

Conforming IS Specification

Capacity (kg.)

Filling Ratoi

Type of Extinguisher

Type of Extinguishing Media

Expellant

Minimum Effective Discharge (%)

Minimum Discharge Time (Sec)

Minimum Throw (mtr)

Operating Position

Operative Valve (IS 3224)

Operating Temperature Range (C)

Fire Rating

FC-2

15683

2

0.667

CO Type2 CO Type2

Self Self

95 95

More than 8 More than 8

1 1

Upright Upright

FC- 4.5

15683

4.5

0.667

Squeeze Grip/Wheel Type

Squeeze GripWheel Type

(-)20 to (+) 55 (-)20 to (+) 55

8B 13B

CO Gas2 CO Gas2Conforming to IS : 15222 Conforming to IS : 15222

ALWAYS USE FIRE ESCORT ABC STORED PRESSURE TYPE FIRE EXTINGUISHER,IF YOU ARE NOT TRAINED TO TACKLE DIFFERENT TYPE OF FIRES

A System That Acts Before We DoA SYSTEM THAT DOESN'T ALERTTS BUT ACTS

B Oil, Kerosene, PetrolPaint etc.

C Flammable Gases

ElectricallyStarted Fires

Foam 9 Litre Map 25 Kg Clean Agent 2 KgWater 9 Litre

FIRE KILLS YOU CAN PREVENT IT