acticap

2
www.brainproducts.com Brain Products is proud to present actiCAP, another ground- breaking development aimed at raising EEG & ERP research to the next level. actiCAP combines active electrodes with a new type of integrated noise subtraction circuits delivering even lower noise levels than any other „normal“ active electrodes achieve. But that‘s not all: actiCAP can be connected to nearly any existing research EEG amplifier system. All of our amplifiers as well as most of our competitors’ amplifiers will work with actiCAP. If you decide to switch from passive to active electrodes you will no longer be forced to exchange your entire recording system. Simply keep your existing hardware, and the acquisition and analysis software you are used to working with and add the actiCAP to reduce your preparation time e.g. for 64 channels down to 5 minutes. The third generation of active electrodes Enlighten your Research Recording EEG the progressive way

Upload: psyquis

Post on 26-Oct-2014

173 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: actiCAP

ww

w.b

rain

pro

du

cts

.co

m

Brain Products is proud to present actiCAP, another ground-

breaking development aimed at raising EEG & ERP research

to the next level. actiCAP combines active electrodes with a

new type of integrated noise subtraction circuits delivering

even lower noise levels than any other „normal“ active

electrodes achieve.

But that‘s not all: actiCAP can be connected to nearly any

existing research EEG amplifier system. All of our amplifiers

as well as most of our competitors’ amplifiers will work with

actiCAP. If you decide to switch from passive to active electrodes

you will no longer be forced to exchange your entire recording

system. Simply keep your existing hardware, and the

acquisition and analysis software you are used to working with

and add the actiCAP to reduce your preparation time e.g. for 64

channels down to 5 minutes.

The third generation of active electrodes

Enlighten your ResearchRecording EEG the progressive way

Page 2: actiCAP

Technical Specification:

Classification MDD 93/42/EEC, Class IIa

Patient Safety Protection class II, EMC tested, Type BF (DIN EN IEC 60601)

Safety requirements:

The third generation of active electrodes

actiCAP control software

ww

w.b

rain

pro

du

cts

.co

m

Amplification 1 (Tolerance < 0,001%)

Input impedance > 200 MOhm

Bandwith DC - 5000 Hz

Noise < 2 µV p.p. (0.1 - 35 Hz)

Dynamic range ±1000 mV

Impedance measurement frequency

30 Hz

Impedance working range 1 to 120 kOhm

Impedance display LED at electrode(colors: red, yellow, green)

Default impedance values green < 25 kOhmyellow 20-60 kOhmred > 60 kOhm

Test signal generation Sinewave 200 µV

actiCAP control software Threshold selection, impedance display (values storable), topographic verification setup, USB connection

Configuration 16, 32, 64, 96, 128 channels

Power 4 AA rechargeable NIMH batteries (1.5 V) or USB powered

Power indication Good/Bad (less than 2 hours remaining)

Working temperature 0°C / +40°C

Software requirements Windows XPWindows Vista

Other Specifications:

Technical changes can be made without prior notification.

ww

w.b

rain

pro

du

cts

.co

m

Version 005 01/2010© Brain Products GmbH

Further information can be obtained from your local distri-butor or directly from:

Brain Products GmbHZeppelinstrasse 782205 Gilching (Munich)Germany

Tel. +49 (0) 8105 733 84 0Fax +49 (0) 8105 733 84 [email protected]

www.brainproducts.com

Worldwide Caution:Limited by United States Law to Investigational Use. ID in accordance with 801.1 For research use only.

ISO 13485:2007

MDD 93/42/EEC

Components:actiCAP control box, Electrode sets (16-/32-/64-/96-/ 128-channel sets), Ground/reference electrode, Cap with holders, USB cable, Batteries & charger, Amplifier connection cable and adapter, acti-CAP control software, Manual