Page 1: Aesculap Orthopaedics Metha

Evolving the State of Arthroplasty

Aesculap OrthopaedicsMetha®

Short Hip Stem

Page 2: Aesculap Orthopaedics Metha

2

Evolving the State of Arthroplasty

Page 3: Aesculap Orthopaedics Metha

3

Short Hip Stem System 4

Short Stem Anchoring Concept 6

Variable Implant Options 8

Less-Invasive Surgery 10

Navigation with OrthoPilot® 12

Planning and Surgical Technique 14

Femoral Osteotomy 16

Implant and Rasp Position 18

Trial Reduction and Stem Implantation 20

Modular Stem Implantation 22

Explantation of the Stem 24

Handles for Different Approaches 25

Instruments and Implants Ordering Information 26

Contents

Page 4: Aesculap Orthopaedics Metha

4

Short Hip Stem System

Page 5: Aesculap Orthopaedics Metha

5

The Metha Short Hip Stem implant represents a new generation of implantsfor hip endoprosthesis. It combines threekey advantages facilitating surgeries thatare as minimally invasive as possible:modular design, minimal stem size and acircumferencial coating. It is particularlysuitable for young patients with good bonequality.

The design continues on the positive experience with non-cemented stems fixated by metaphyseal anchoring. The implant concept allows implantation viathe base of the femoral neck, with conservative treatment of the bone in thefemoral neck and in the greater trochanterregion, preserving the bone, soft tissueand muscle. While the position of theMetha stem ensures primary load stability,the Plasmapore® µ-CaP coating of the entireproximal surface supports rapid secondaryfixation.

One of the special advantages of the systemis its modular design with various neckadapters. This solution decouples the stemposition from that of the head, which makesit possible to a large extent to adapt thestability and mobility of the joint to theindividual patient. The Metha system alsoincludes non-modular standard shortstems with two neck angles.

The implantation instruments are as sophisticated as they are simple. Metha isat the leading edge of technology. Combining the modular stem with the OrthoPilot® navigation technology expandsthe possibilities for hip replacement surgery even further. The sequential orderof cup and stem implantation can be chosen by the surgeon.

System

Page 6: Aesculap Orthopaedics Metha

66

Short Stem Anchoring Concept

Page 7: Aesculap Orthopaedics Metha

7

The non-cemented stem is fixated by metaphyseal anchoring within the closedring of the femoral neck. The greater trochanter region remains completely untouched. Bone and muscle structuresare preserved, making the Metha ShortStem Hip an excellent choice for youngand active patients with good bone structure. The conical shape supports primary stability and proximal force transfer. The high primary stability isfurther enhanced by the rounded tip ofthe stem guided along the dorso-lateralcortex. 3

2

1

1

2

3

Metaphyseal

Page 8: Aesculap Orthopaedics Metha

8

Variable Implant Options

130° 135° 140°

130° 135°

Page 9: Aesculap Orthopaedics Metha

9

Metha VariabilityThe nine modular neck adapters allow a variety ofoffset and version options for stem implantation. TheCCD angle specifications of 130°, 135° and 140°relate to a stem position at a 50° osteotomyplane. The Metha stem position allows approximately 20° of varus/valgus variability. Theimplant range also allows for balancing with respect to leg length and anteversion or retroversion respectively (± 7.5°).

10.2

5 cm

10.7

5 cm

11.2

5 cm

11.7

5 cm

7.5° Ante 0° 7.5° Retro

Metha implantsThe implant sizes range increase in increments of 1.5 mm in the A/P projectionand 1.2 mm in the lateral projection. Anchorage in the closed femoral neck issupported by the conical shape in the lateral view. The difference in nominallength between the smallest and largest implant is only 2 cm.

*Only available with Metha Non-Modular

12.2

5 cm

12.2

5 cm

size

2

size

3

size

5

size

6

size

7*

size

4

Implants

Page 10: Aesculap Orthopaedics Metha

Less-Invasive Surgery

10

Page 11: Aesculap Orthopaedics Metha

11

Simple and clear instrumentation is a distinguishing feature of the Metha StemSystem. Due to a more medial location ofthe femur opening, and the medially tilted insertion angle, the Metha implant is ideally suited for minimally-invasive andless-invasive implantation techniques.

The MIOS® (Minimally Invasive OrthopaedicSolutions) instrument range has been specially designed for less invasive joint replacement procedures. MIOS special retractors, curved instrument profiles andMetha rasp handles facilitate all widelyused approaches to the hip joint(see page 25).

The lateral position allows the direct lateral, anterolateral and posterior approaches. In supine position the directlateral approach, anterolateral approachand direct anterior approach are possible.

1 Tensor fascia latae2 Sartorius3 Rectus femoris4 Gluteus minimus5 Gluteus medius6 Gluteus maximus7 Piriformis

A Direct AnteriorB AnterolateralC Direct Lateral, TransglutealD Posterior

1 2

3

4

5

6

7

A

B

C

D

Instruments

Page 12: Aesculap Orthopaedics Metha

12

Navigation with OrthoPilot®

Page 13: Aesculap Orthopaedics Metha

13

Metha can be implanted using the OrthoPilot Navigation System. The clinically proven standard THAnavigation software allows complete navigation of thearticular parameters of the cup and stem componentsto optimize the range of motion.

The modularity of the Metha system helps with theintraoperative selection of implants by offering a multitude of options for CCD angle and relative anteversion and retroversion angles in relation to thecup component and the selected head diameter.

The new THAplus software only needs one transmitteron the pelvis for the entire navigation procedure andit supports all minimally-invasive approaches. Thefunctions of the kinematic cup navigation are extendedby leg length and offset controls. The position of thefemur is palpated intraoperatively to register the leglength and offset parameters for optimal implant selection.

Navigation

Page 14: Aesculap Orthopaedics Metha

Planning and Surgical Technique

14

Page 15: Aesculap Orthopaedics Metha

15

Indications and Bone Morphology

The Metha Short Hip Stem is a modern,cementless implant. The spectrum of indications includes degenerativecoxarthrosis and femoral head necrosis.Good bone quality is a prerequisite for asuccessful implantation.

A significant coxa vara or a short femoralneck are less suitable bone shapes for thistherapy.

The pre-operative assessment involveschecking for a wide femoral neck, especially in the presence of other concerns regarding the osteotomy level orthe implant size. An undersized stem could lead to reduced primary stability. The pre-operative assessment with the planning template is very important.

Any strong anteversion of the femoralneck can complicate the implantation evenfor short stems. Therefore, the pre-operative planning must also include alateral x-ray.

Pre-operative Planning

X-ray templates at a scale of 1.15:1 are available forplanning the size of the Metha Short Hip Stem implant. The aim is to:

• Fill the femoral neck area• Achieve support on the calcar• Achieve surface contact between the distal end

of the stem and the lateral cortex.

In addition to the position of the joint center and theleg length, planning the resection height is also veryimportant. The preservation of the approximately 5 - 10 mm thick ring of cortex around the femoralneck is important for anchorage. The osteotomy ofthe femoral neck is performed ideally at an angle of50° to the femoral shaft axis. To aid intraoperativeorientation, the distance from the lesser trochantercan be measured medially.

In the lateral x-ray, the objective is to wedge firmlyin the proximal femur. The Metha Short Hip Stem isideally positioned in the direction of the femoral neck and shaft.

Surgical Technique

Page 16: Aesculap Orthopaedics Metha

16

Femoral Osteotomy

The femoral neck resection is performedaccording to pre-operative planning. Inmost cases starting approximately 10 mmabove the junction of the greatertrochanter and the femoral neck, and isideally carried out at an angle of 50° tothe femoral axis.Care must be taken that a closed corticalring of the femoral neck of at least 5 mmlateral width is left intact.Any lower resection than described abovecan compromise the implant anchoringand therefore demonstrates a contraindication against the implantation.

If the osteotomy is applied too low mediallyor the osteotomy is too steep, the stem willhave to rest on a smaller medial bone surface. For this stem position, the primarystability comes from the cortical lateralsupport in the closed ring of the femoralneck.

If the osteotomy is too steep and there isinsufficient support on the proximal lateralcortex, there is a risk that the stem movesinto valgus.

The orientation of the implantation depthon a very deep calcar osteotomy can increase the risk of a stem position without lateral support. This can result inthe rasp or implant stem moving into valgus.

Femoral Osteotomy

Flat osteotomy (A) and optimum stem positionat the level of the osteotomy

Steep osteotomy (B) and higher stem positionwith lateral contact at the osteotomy

Steep osteotomy (B) and stem inserted too deeply without lateral contact at the osteotomy

Proper osteotomy level may be achievedthrough two osteotomies

1

2

AB

A BA

X

Page 17: Aesculap Orthopaedics Metha

17

Opening the Medullary Cavity

The medullary cavity is opened with a curved awl. The opening point is at thecenter of the osteotomy plane. The awl isadvanced to the lateral cortex with lighttwisting movements. It is helpful to insertthe awl in slight varus first, then movemore into valgus upon reaching the lateralcortex before pushing it distally along thelateral cortex. The marker dots on the awlare for depth orientation and correspondto the resection height for the small (size1) or larger (size 6) Metha Stem. The curvature of the awl resembles the lateralprofile of the implant so that it produces afirst impression of the subsequent implantbed. The awl also defines the working direction of the rasps.

A second awl with a thicker anterior-posterior profile is available foreasier bone preparation in harder structures.As a general rule, the awls are for manual application only and must not be impacted with a mallet.

50°

To achieve an optimum osteotomy position,the osteotomy can be applied in two steps.First, subcapital osteotomy can be carriedout in situ. The second osteotomy is guidedby the planned implantation depth andstem position. A trapezoidal second osteotomy, (higher at the posterior side

than at the anterior side , see illustration on page 16) allows the influence of the anteversion position andfacilitates the insertion of the rasps.

BA

Page 18: Aesculap Orthopaedics Metha

Implant and Rasp Position

-5°

+5°+10°

+15°

Varus/Valgus Variability

The Metha Short Hip Stem can be implanted at various relative varus/valguspositions to fit the respective bone shapeand implant size. The neutral position isdefined as parallel to a 50° femoral osteotomy.

Other implant positions are up to 5° relative varus or 15° relative valgus.

When preparing the medullary cavity, a position change of the rasp can be detectedby intraoperative comparison with the osteotomy plane.

18

Page 19: Aesculap Orthopaedics Metha

Femur Preparation

The implant bed is prepared in stages, beginning with the smallest rasp.The rasp is introduced centrally into theopening of the medullary canal, observingthe anteversion. During insertion, the tip ofthe rasp should touch the lateral cortexand run along it.

To control the tendency towards valgus ofthe instrument, it helps to apply slight varuspressure when inserting the rasps. The position and alignment of the osteotomycan be checked after inserting the first rasp.Valgus positioning of the rasp can causeunintended leg lengthening. This has to beconsidered when carrying out the pre-operative planning and during the intraoperative selection of the next raspsize.

The lateral boundary of the osteotomymust never be removed by any additionalresection. To assess such a resection, aproper visibility of the lateral femoral neckis essential.

The implant bed is the correct size as soonas the rasp touches the lateral cortex, sitsfirmly in the femoral neck, and cannot rotate anymore. The teeth of the raspshould be aligned to the resection level,but never below the osteotomy plane.

The position of the rasp can be checkedwith the fluoroscopy or x-ray.

If the rasp is not in contact with the dorsolateral cortex in any plane (radiography with internal rotation, seeabove photo), the position should be corrected by carefully inserting a largerrasp under slight varus pressure.

19

Page 20: Aesculap Orthopaedics Metha

Trial Reduction

The trial reduction is carried out using modular trial neck adapters, which are clipped on the rasp. For Metha modular,there are nine neck adapters available withvarious CCD angles (130°, 135°, 140°) andanteversion options (7.5° ante, 0°, 7.5°retro).

The different CCD angles allow changingthe offset by -5 mm / +5 mm withoutchanging the leg length. The neutral offsetis 44 mm for a standard varus/valgus rasp position.

The appropriate neck adapter is selected by assessing the possibility of a luxationtendency, range of motion and the soft tissue or ligamentary tension. The leglength is corrected by choosing an implanthead for the required neck length.

Trial Reduction and Stem Implantation

The OrthoPilot® Navigation System helps you select the best possible implant combination and adapt it tothe individual articular situation. The system computesand displays the parameters of mobility, any implantimpingement, anteversion position and any changes inoffset and leg length associated with each of the possible combinations.

Offset-5 44 mm-10 mm +5 +10

+5

0

-5

= 130° Neck adapter= 135° Neck adapter

= 140° Neck adapter*Head center

Leg

leng

th

S

M

L

S

M

L

S

M

L

140° 135° 130°

20

*Available only for modular Metha implants

Page 21: Aesculap Orthopaedics Metha

Inserting the Metha Non-Modular Stem

The Metha Non-Modular Stems are available with CCD angles of 130° and135°, without anteversion or retroversion.Implantation is carried out with the StemImpactor (NG930R) (Green Handle) or withthe Stem Impactor (ND401R) applied inthe adapter recess (with the orange protective cap in place).

Implanting the Head

The final trial reduction is followed by theimplantation of the head. Careful cleaningand drying of the 12/14 trunnion head interface is absolutely essential.

Selection of Metha Modular Stem Sizeand Neck Adapter

The implant stem to be inserted is selected according to the size of the finalrasp. The selection of the neck adapter isguided by the trial reduction performedwith the implantation rasp and finished bya reduction check of the selected implant head length.

NG930R

Assembling the Metha Modular AdapterPrior to Implantation

The modular implant components (Methastem and neck adapter) are assembledprior to the implantation. With the orangeprotective cap in place, they are joined together by impacting on the recess in the neck adapter center using the StemImpactor (ND401R).

Then the Metha Stem is inserted by handmaking sure to point the arrow (�) medially and implanted by impacting onthe recess in the neck adapter using theStem Impactor (ND401R).

Once the adapter is securely and firmly fixed in the Metha Stem, the stem can be implanted by applying the same stemimpactor in the lateral recess of the Metha Stem. This is followed by a trial reduction with modular heads.

ND401R

21

Page 22: Aesculap Orthopaedics Metha

Careful Cleaning of the Cone Surfaces

Before the neck adapter can be inserted,the inner socket of the stem must be carefully rinsed, cleaned and dried. The surfaces of the neck adapter must be alsoclean and dry. Cleaning swabs (ND622) areavailable for this purpose.

Modular Stem Implantation

Inserting the Neck Adapter

The selected neck adapter is inserted into the implant stem with the marker arrow pointing medial (�) and driven in lightly but firmly with thestem impacter. To avoid damage to the trunnion, theprotective cap is only removed after the neck adapterhas been driven firmly into place.A trial reduction is performed with trial implant heads.After cleaning and drying of the implant cone adapterthe final head is inserted and the joint reduced. Finally, the joint mobility, range of motion, articulartension and leg length are checked.

Caution

The cone surfaces must be cleaned anddried under all circumstances, as uncleanor damaged connecting surfaces may leadto implant failure. Always follow the instructions for use supplied with the implant components. We recommend assembling the Metha Stem and the modular neck adapters prior to implantation.

!

22

Page 23: Aesculap Orthopaedics Metha

The relative anteversion or retroversion position of the trial adapter can be corrected by 7.5°. The marking of theadapters is dependent on the implantationside. The CCD angle influences the soft tissue tension by changing the offset.

The relative retroversion or anteversion canalso be selected according to the positionor cup coverage of the trial implant headafter the trial reduction.

Option: Trial Reduction with Metha Stem

The Metha Stem is inserted as deep as possible by manual pressure and then drivenwith the stem impacter (ND401R) into itsfinal, fixed position. The implant does notneed to be guided as it aligns itself with therasped cavity.

If guidance of the implant stem is necessaryduring the implantation, the ND655R Impactor/Extractor Instrument may be used,making sure that the inner socket of thestem is not damaged under any circumstances. The same instrument canalso be used for extracting the stem (see page 24).

If necessary, an additional trial reduction canbe carried out even after the implantation ofthe Metha Stem using the color-coded modular trial neck adapters and trial heads.The instructions for cleaning the modularadapter prior to insertion must be closely followed (see page 22).

140°

7.5° Retro

135°

7.5° Retro

130°

7.5° Retro

140°

135°

130°

140°

7.5° Ante

135°

7.5° Ante

130°

7.5° Ante

Decrease Anterior Luxation Tendency

Decrease Posterior Luxation Tendency

Incr

ease

Low

Sof

t-Ti

ssue

Ten

sion

Decr

ease

Sof

t-Ti

ssue

Ten

sion

23

Page 24: Aesculap Orthopaedics Metha

24

Removing the Neck Adapter

To remove the Metha Modular Stem, firstextract the modular neck component fromthe stem. The extractor is applied andtightened between the surface of the stem

and the modular neck component.

The connection between the two components is loosened by pulsed impactswith a hammer on the extractor. Theextractor is carefully retightened betweenthe hammer blows. 2

3

21

Explanting the Stem

Once the modular neck adapter has beenremoved, the stem explantation instrumentis screwed firmly into the thread of thestem. The stem can then be explantedusing a slotted hammer. If the stem hasbecome strongly ingrown in the bone, aflexible osteotome is applied around thecoated area of the stem (anterior, poste-rior, lateral then medial).Since the surfaces are straight, it is also possible to use an oscillating saw (bladewidth 10 mm, depth 30 mm).

Extraction of the Metha Non-ModularStem

The Metha Non-Modular Stem can be extracted intraoperatively, if necessary,with the ND656R instrument. This instrument, which grips around the 12/14trunnion, is connected to the ND655R extraction instrument. The stem must notbe reused after an extraction since thecone could be damaged during this procedure.The extraction of a strongly ingrownMetha Non-Modular Stem is carried out inthe same way as the standard hip stems,using a stem extractor for the 12/14 trunnion.

ND656R

Explantation of the Stem

ND655R

ND646R1

2

3

Page 25: Aesculap Orthopaedics Metha

25

* Note:NF141R for the left hip (lateral and anterolateral approaches) or right hip (posterior approach)NF142R for the right hip (lateral and anterolateral approaches) or left hip (posterior approach)

NF140R

NF140RAngled handle for direct anterior approach

NF180RStraight handle for lateral and anterolateral approaches

NF141R, NF142ROffset handles*

NF144RCurved handle for posterior approach

NF142R

NF144R

Handles for Different Approaches

NF180R

NF141R

Page 26: Aesculap Orthopaedics Metha

Tray 1ND613R Perforated tray for tray 1TE928 Graphics template for tray 1JH217R Tray lidND644R Metha awl narrowND645R Metha awl wideND656R Metha extraction instrument for 12/14 trunnionNF180R Straight, lateral approach

Metha RaspsSize 1 2 3 4

NF181R NF182R NF183R NF184RSize 5 6 7

NF185R NF086R NF087R

Metha Rasp Trial Neck Adapters130° 135° 140°

7.5° L Ante R Retro ND714R ND724R ND734R0° ND715R ND725R ND735R7.5° L Retro R Ante ND716R ND726R ND736R

Metha Trial Neck Adapters130° 135° 140°

7.5° L Ante R Retro ND627 ND637 ND6470° ND628 _ ND6487.5° L Retro R Ante ND629 ND639 ND649

Trial Heads 12/14Head Neck Length 28 mm 32 mm 36 mmS -4 NG296 NG306 NG326M 0 NG297 NG307 NG327L +4 NG298 NG308 NG328

Metha® ModularInstruments and Implants

Tray 1 Tray 2

Tray 2ND614R Perforated tray for tray 2TE929 Graphics template for tray 2JH217R Tray lidNF275R Slotted hammer, slot W = 12 mmND655R Metha impaction/extraction handleNG930R Metha Non-modular impactorND401R Metha standard impactorND646R Metha modular neck extractor

ContainerJK486 Container LidJN444 Container

Tray 3JH213R TrayJH217R Tray LidJF932 Silicone PadND050 Head Impactor

Metha Rasp HandlesNF141R Offset, left/rightNF142R Offset, right/leftNF144R Curved, posterior approach

ContainerJK486 Container LidJN444 Container

Optional Instrument (Order separately)NF140R Angled, direct anterior approach

26

Tray 3

Page 27: Aesculap Orthopaedics Metha

Plasmapore® µ-CaP

ISOTAN® F

Metha Modular Stemswith trial neck adapter 135°/0°

Stem Size Modular2 NC082T3 NC083T4 NC084T5 NC085T6 NC086T

Modular Neck Adapters12/14 trunnion

Cone 12/14

135°

ISODUR®F

140°

CCD Angle Offset130° 135° 140°+ 5 mm 0 mm - 5 mm

Correction Anteversion7.5° L Ante / R Retro NC077K NC087K NC097K

0° NC078K NC088K NC098K7.5° L Retro / R Ante NC079K NC089K NC099K

130°

Cleaning SwabsND622 10 Cleaning swabs for inner cone (Order separately)

27

Implant Materials:

ISOTAN®F - Titanium forged alloy

(Ti6Al4V / ISO 5832-3)

Plasmapore® µ-CaP - Pure titanium surface with 20 µm coating dicalcium phosphate dihydrate (CaHPO4x2H2O)

Biolox® forte - Aluminum oxide

ceramics (Al2O3 / ISO 6474)

ISODUR®F - Cobalt-Chromium

forged alloy (CoCr29Mo / ISO

5832-12)

UHMWPE - Ultra-high molecular

weight polyethylene (ISO 5834-2)

Page 28: Aesculap Orthopaedics Metha

Tray 2

Metha® Non-ModularInstruments and Implants

28

Tray 1

Tray 1ND609R Perforated tray for Non-modular setTE931 Graphics template for Non-modular setJH217R Tray lidND644R Metha awl narrowND645R Metha awl wideND656R Metha extraction instrument for 12/14 trunnionND655R Metha impaction/extraction handleNG930R Metha Non-modular stem impactorND715R Rasp trial neck adapter 130°/0°ND725R Rasp trial neck adapter 135°/0°NF180R Metha Rasp Handle Straight

Metha RaspsSize 1 2 3 4

NF181R NF182R NF183R NF184RSize 5 6 7

NF185R NF086R NF087R

Trial Heads 12/14Head Neck Length 28 mm 32 mm 36 mmS -4 NG296 NG306 NG326M 0 NG297 NG307 NG327L +4 NG298 NG308 NG328

Tray 2JF932 Silicone PadJH213R TrayJH217R Tray LidND050 Head Impactor

Metha Rasp Handles, also for NavigationNF141R Offset, left/rightNF142R Offset, right/leftNF144R Curved, posterior approach

ContainerJK486 Container LidJN444 Container

Optional Instrument (order separately)NF140R Angled, direct anterior approach

Metha Stems with 12/14 trunnionStem size CCD = 130° CCD = 135° Stem size CCD = 130° CCD = 135°

2 NC272T NC282T 5 NC275T NC285T3 NC273T NC283T 6 NC276T NC286T4 NC274T NC284T 7 NC277T NC287T

130°

12/14

135°

12/14

Plasmapore® µ-CaP

ISOTAN® F

Page 29: Aesculap Orthopaedics Metha

29

Short

Medium

Long

28 mm

NK460

NK461

NK462

32 mm

NK560

NK561

NK562

Plasmacup® SC µ-CaP

ISOTAN ®F

NC444T

NC446T

NC448T

NC450T

NC452T

NC454T

NC456T

NC458T

NC460T

NC462T

NC464T

NC466T

NC468T

44 mm

46 mm

48 mm

50 mm

52 mm

54 mm

56 mm

58 mm

60 mm

62 mm

64 mm

66 mm

68 mm

SC Polyethylene Cup Liners

44 mm46 mm

48 mm50 mm

52 mm54 mm

56 mm58 mm

60 mm62 mm

64 mm66 mm68 mm

28 mm

NH191

NH192

NH193

NH194

NH195

NH196

32 mm

NH202

NH203

NH204

NH205

NH206

28 mm

NH401

NH402

NH403

NH404

NH405

NH406

32 mm

NH413

NH414

NH415

NH416

UHMWPE

Symmetric Posterior Wall

Heads

12/14

Implant Materials:

ISOTAN®F - Titanium forged alloy

(Ti6Al4V / ISO 5832-3)

Plasmapore® µ-CaP - Pure titanium surface with 20 µm coating dicalcium phosphate dihydrate (CaHPO4x2H2O)

Biolox® forte - Aluminum oxide

ceramics (Al2O3 / ISO 6474)

ISODUR®F - Cobalt-Chromium

forged alloy (CoCr29Mo / ISO

5832-12)

UHMWPE - Ultra-high molecular

weight polyethylene (ISO 5834-2)

12/14

ISODUR®F

28 mm

NK429K

NK430K

NK431K

32 mm

NK529K

NK530K

NK531K

Short

Medium

Long

36 mm*

NK650

NK651

NK652

BIOLOX® forte* Only available with Metha Non-Modular stems

Plasmacup® Implants and Heads

Page 30: Aesculap Orthopaedics Metha

Notes

30

Page 31: Aesculap Orthopaedics Metha

31

Page 32: Aesculap Orthopaedics Metha

Aesculap Implant Systems, Inc.

3773 Corporate ParkwayCenter Valley, PA 18034Phone: 866-229-3002

www.aesculapimplantsystems.com©2008 AESCULAP. ALL RIGHTS RESERVED. PRINTED IN THE USA. DOC787 3M 8/08Aesculap is an equal opportunity employer

All rights reserved. Technical alterations are possible. The information provided in thisleaflet is distributed by Aesculap Implant Systems, Inc. for educational purposes andnot for the purpose of rendering medical advice. The material in this leaflet is not instructional and should NOT be relied upon by surgeons and staff as adequatetraining for performing the surgeries illustrated. This brochure is intended for healthcare professionals and employees, not for patients. The information presented is not asubstitute for a medical examination and opinion by a licensed physician regarding apatient’s diagnosis or recommended course of treatment. This leaflet may be used forno other purposes than offering, buying and selling of our products. No part may becopied or reproduced in any form. In the case of misuse we retain the rights to recallour catalogs and price lists and to take legal actions.