aftercoolers web
TRANSCRIPT
7/29/2019 Aftercoolers Web
http://slidepdf.com/reader/full/aftercoolers-web 1/2
Air-Cooled Aftercoolers ACHV, ACH An d ACV Mode ls
Cools Compressed Air
Prcit i air fr furthr f i trig a ryig!Hankison air-cooled atercoolers use ambient air to cool the hot air
leaving an air compressor (typically 180°F to 350°F [82°C to 177°C] )
to usable levels 100°F to 120°F (38°C to 49°C] ). As the air cools about
70% o the water vapor present condenses into liquid water which can
thenbe removed with a separator.
Economical, air-cooled atercoolers use ambient air to remove heat
rom the compressed air. Atercoolers can be sized to cool the
compressed air to within 5° to 20°F (3° to 11°C) o the ambient air
temperature.
Atercoolers can also be installed so that normally wastedheat can be
reclaimed and used (such as or space heating)
ACHV M
• Sizes rom 20 to 100 scm (33.9 to 169.9 nm3/h)*
• May be mounted or horizontal or vertical air ow
• Lightweight, UPS shippable
• May be mounted on oor or suspended
• Cooling coils: » Corrugated aluminum fns and copper tubes increase heat transer rate;
heavy gauge aluminum resists external damage
• Heavy gauge aluminum an blades
ACH M
• Sizes rom 35 to 300 scm (59.5 to 509.7 nm3/h)*
• Horizontal air ow
• Galvanized steel cabinet
• May be mounted on oor or suspended
• Cooling coils designed rom corrugated aluminum fns and coppe
tubes increase heat transer rate; heavy gauge aluminum resists
external damage
• Heavy gauge aluminum an blades
ACV M
• Sizes rom 400 to 3500 scm (679.6 to 5946.5 nm3/h)*
• Vertical air ow
• Unitized, aluminum core heat exchanger
• Cooling coils eature a durable aluminum plate core design saving
space and minimizing energy usage
• TEFC an motors
• Polypropylene blades on aluminum hub
7/29/2019 Aftercoolers Web
http://slidepdf.com/reader/full/aftercoolers-web 2/2
SPX reserves the right to incorporate our latest design and material changes without notice or obligation. Design eatures, materials o construction and dimensional data, as described in this bulletin, are
provided or your inormation only and should not be relied upon unless confrmed in writing. Please contact your local sales representative or product availability in your region. For more inormation visit www.
spx.com. The green “>” is a trademark o SPX Corporation, Inc.
ISSUED 01/2012 ACA COPYRIGHT © 2012 SPX Corporation
1000 Philadelphia Street Canonsburg, PA 15317-1700 USA
P: (724) 745-1555 F: (724) 745-6040 E: [email protected]
Based in Charlotte, North Carolina, SPX Corporation (NYSE: SPW) is a global Fortune 500 multi-industry manufacturing leader.
For more information, please visit www.spx.com
Air-Cooled Atercoolers Product Specifcations
M
It Tmp
150ºF 200ºF 250°F 300°F 350°F
66°C 93°C 121°C 149°C 177°C
Ap pr a ch Tmp .5ºF 10ºF 15ºF 20ºF 5ºF 10ºF 15ºF 20ºF 5ºF 10ºF 15ºF 20ºF 5ºF 10ºF 15ºF 20ºF 5ºF 10ºF 15ºF 20ºF
3ºC 6ºC 8ºC 11ºC 3ºC 6ºC 8ºC 11ºC 3ºC 6ºC 8ºC 11ºC 3ºC 6ºC 8ºC 11ºC 3ºC 6ºC 8ºC 11ºC
AC HV -2 0 17 35* 3 5* 3 5* 11 22 35 35* 8 16 20 35 6 12 19 26 5 10 15 21 AC HV -3 5 29 43* 43* 43* 17 36 43* 43* 12 27 35 42* 10 20 31 42* 8 16 26 35
AC HV -5 0 43 72 72* 72* 28 50 70 72* 22 35 50 70 18 32 45 57 15 28 39 50
AC HV -1 00 95 125* 125* 125* 66 11 125* 125* 52 88 100 1 25* 44 74 100 125 38 64 86 108
AC H- 35 25 42 58 73 18 31 43 53 15 25 35 44 13 22 30 37 11 19 26 32
AC H- 50 34 58 79 99 25 43 59 74 21 36 50 62 18 31 42 52 16 27 38 47
AC H- 65 42 73 99 125 32 55 77 95 27 47 65 81 24 41 57 71 22 37 52 65
AC H- 80 50 87 119 150 40 69 94 117 34 59 80 100 30 52 71 89 28 47 65 82
AC H- 10 0 60 102 140 177 48 81 112 140 43 73 100 124 38 64 87 110 34 59 81 100
AC H- 12 0 81 138 190 235 61 105 142 177 51 87 120 150 43 75 102 127 40 69 94 116
AC H- 15 0 92 160 220 270 73 125 172 215 63 110 150 187 55 95 130 160 50 86 120 148
AC H- 24 0 160 275 380 425* 120 207 285 355 100 175 240 300 84 145 204 250 78 135 185 231
AC H- 30 0 184 318 440 480* 145 250 345 430 125 217 300 375 110 190 257 320 100 175 240 300
AC V- 40 0 210 384 520 605 175 375 430 500 160 300 400 464 135 250 340 396 125 235 305 355
AC V- 72 5 355 650 890 1025 308 560 760 880 290 545 725 840 245 450 605 701 225 410 540 625
AC V- 95 0 480 871 1178 1360 415 754 1020 1180 390 712 950 1100 320 588 785 910 280 520 690 780
AC V- 12 00 600 1090 1 475 1 710 520 950 1290 1 460 490 900 1200 1 380 405 735 980 1130 355 650 865 990
AC V- 16 00 7 90 1 440 1 95 0 22 60 7 10 1 29 0 17 20 1 95 0 66 0 1 20 0 16 00 1 86 0 53 0 9 65 1 29 0 14 80 4 60 84 0 1 13 5 130 0
AC V- 20 00 9 80 1 790 24 20 2 800 8 70 1 58 0 2 14 0 2 46 0 82 0 1 49 0 2 000 23 00 66 0 12 10 1 59 5 1 840 5 72 1 040 1 40 0 1 61 0
AC V- 25 00 1 22 0 2 22 0 3 00 0 3 47 0 1 09 0 1 98 0 2 68 0 3 10 0 1 03 5 1 88 0 2 50 0 2 87 0 7 84 1 42 6 1 98 0 2 27 0 7 05 1 29 0 1 72 5 1 98 0
AC V- 30 00 1 45 0 2 65 0 3 58 0 4 12 0 1 29 5 2 36 0 3 20 0 3 71 0 1 24 3 2 26 0 3 00 0 3 45 0 9 85 1 79 4 2 36 0 2 71 5 8 40 1 53 0 2 04 0 2 35 0
AC V- 35 00 1 68 0 3 06 4 4 14 0 4 80 0 1 53 0 2 78 5 3 76 0 4 32 0 1 46 0 2 66 0 3 50 0 4 01 5 1 15 0 2 09 0 2 76 0 3 20 0 9 50 1 74 0 2 35 0 2 70 0
Scfm ( for HZ operat ion mul t ip ly sc fm by 0 .90)Above spec i f icat ions are based on 80 to 125 psig (5 .6 to 8 .8 bar ) operat ing pressures. Max imum pressure drop, less than 3 psig (0 .21 bar ) .*Max imum rat ings rest r ic ted by pressure drop, ac tua l thermal capac i t ies are h igher .Max imum operat ing pressure: 250 psig (17.6 bar )Max imum operat ing temperature: 350°F (177°C)
M
Fa Mtr data dimi Ccti Wight
A B C
H P Typ Vt/ Ph/Hz i n PT b
AC HV -2 0- V 1/12 O DP115/1/60
230/1/60
115/1/50
230/1/50
15.9 20.4 13 .3 .5 25 AC HV -2 0- H 1/12 O DP 21.9 20.4 9.6 .5 25 AC HV -3 5- V 1/12 O DP 15.9 20.4 13 .3 .5 27 AC HV -3 5- H 1/12 O DP 21.9 20.4 9.6 .5 27 AC HV -5 0- V 1/12 O DP 40.1 26.1 17 .4 1 61 AC HV -5 0- H 1/12 O DP 42.2 26.1 15.4 1 61 AC HV -1 00 -V 1/12 O DP 40.1 26.1 17.4 1 .5 67 AC HV -1 00 -H 1/12 O DP 42.2 26 .1 15.4 1 .5 67
AC H- 35 1/ 4
115Vava i lab le
in ODP
or TEFC,
a l l o thers
TEFC
115/1/60208-230/1/60
208-230/3/60
460/3/60
190-200/3/50
380-415/3/50
46.5 14 .8 30.5 1 110
AC H- 50 1/4 46 .5 14 .8 30.5 1 110 AC H- 65 1/4 46 .5 14 .8 30.5 1 .5 120 AC H- 80 1/4 46 .5 14 .8 30.5 1 .5 120
AC H- 10 0 1/4 46 .5 14 .8 43.5 1 .5 140 AC H- 12 0 1/4 46 .5 14 .8 43.5 1 .5 140 AC H- 15 0 1/4 46 .5 14 .8 43.5 1 .5 145 AC H- 24 0 1/4** 46 .5 14 .8 47.6 2 200 AC H- 30 0 1/4* * 55 .5 14 .8 51.7 2 300 AC V- 40 0 1.0 TE FC 1, 2 , 4 34 .2 22 .7 18.0 2 120 AC V- 72 5 1.5 TE FC 1, 2 , 4 34 .2 30 .6 22.4 2 170 AC V- 95 0 1.5 TE FC 1, 2 , 4 36 .0 37 .2 26 .8 3 330
AC V- 12 00 3.0 TE FC 2, 5 36.0 41.2 26 .8 3 450
AC V- 16 00 5.0 TE FC 2, 5 36.0 41.2 34 .9 3 515
AC V- 20 00 7.5 TE FC 3, 5 36.0 51.0 37 .9 4 600
AC V- 25 00 7.5 TE FC 3, 5 36.0 49.1 43 .7 4 625
AC V- 30 00 10 TE FC 3, 5 36.0 51.0 52 .5 4 645
AC V- 35 00 10 TE FC 3, 5 36.0 51.0 56 .3 4 750
* Dual Vol tage - motor may be wi red for e i ther vo l tage shown
1) 2) 3) 4) 5)
* * Models ACH-240 and ACH-300 have 2 fan motorsODP - Open Dr ip Proof TE FC - Tota l ly Enc losed Fan Cooled
*
*
*115/1/60
208-230/1/60 *208-230/3/60
460/3/60 *230/3/60
460/3/60 *190-200-208-220/3/50
380-400-416-440/3/50 *190-200-208/3/50
380-400-416/3/50