1 with the Field-IQ Crop Input Control System Quick Reference Card Cable assembly, power to cab (P/N 76941) Ag25 GNSS antenna (P/N 68040-OOS) CONNECTING THE SYSTEM Cable assembly, display to Field-IQ (P/N 50449) Connect to port A or B only. Field-IQ master switch box (P/N 75050-01) FmX integrated display FmX power bus (P/N 67259) Power bus (P/N 67259) Basic power cable (P/N 67258) IBRC to DPT adaptor cable (optional) (P/N 77413) Cable assembly, CAN, cab to hitch (P/N 77368) Remote foot switch (optional) (P/N 60490) TNC/TNC right-angle cable (P/N 50449) 12-section switch box (optional) (P/N 75060-01) FmX power cable (P/N 566694) Note: For more information on system calibration and settings, see the Field-IQ chapter in the FmX Integrated Display User Guide. Field-IQ Master Switch Box Switch Positions c Increment/decrement d Rate Rate 1, Rate 2, Manual e LED indicator f Automatic/Manual section control Switch from Automatic to Manual mode while travelling. g Master Off, On, Jump Start. Use the Jump Start function if you lose the GPS signal or if you want to start applying before the implement is up to speed. Field-IQ 12-section Switch Box (optional) Item c LED indicator d Section switches e Space to write which row the switch controls. Master Switch setting 12-section switch position Then ... Automatic Up / On Section controlled by display. Down / Off Section off. Manual Up / On Section turned on. Down / Off Section off. c d e f g c d e

Upload: vuongthu

Post on 04-May-2018

224 views

Category:

Documents


3 download

TRANSCRIPT

Page 1: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

1

with the Field-IQ™ Crop Input Control SystemQuick Reference Card

Cable assembly, power to cab (P/N 76941)

Ag25 GNSS antenna (P/N 68040-OOS)

COnnECtinG thE SyStEM

Cable assembly, display to Field-IQ (P/N 50449)

Connect to port A or B only.

Field-IQ master switch box (P/N 75050-01)

FmX integrated display

FmX power bus (P/N 67259)

Power bus (P/N 67259)

Basic power cable(P/N 67258)

IBRC to DPT adaptor cable (optional) (P/N 77413)

Cable assembly, CAN, cab to hitch (P/N 77368)

Remote foot switch (optional) (P/N 60490)

TNC/TNC right-angle cable (P/N 50449)

12-section switch box (optional) (P/N 75060-01)

FmX power cable (P/N 566694)

Note: For more information on system calibration and settings, see the Field-IQ chapter in the FmX Integrated Display User Guide.

Field-iq Master Switch box

Switch Positions

c Increment/decrement

d Rate Rate 1, Rate 2, Manual

e LED indicator

f Automatic/Manual section control

Switch from Automatic to Manual mode while travelling.

g Master Off, On, Jump Start. Use the Jump Start function if you lose the GPS signal or if you want to start applying before the implement is up to speed.

Field-iq 12-section Switch box (optional)

itemc LED indicator d Section switches

e Space to write which row the switch controls.

Master Switch setting

12-section switch position

then ...

Automatic Up / On Section controlled by display.Down / Off Section off.

Manual Up / On Section turned on.Down / Off Section off.

c d e f g c d

e

Page 2: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

2

OPEratinG in thE FiELdrun screen

item description

c Field-IQ Plugin tab

d Tank/Bin button Shows capacity, warning level, current volume, and the Refill Tank/Bin and Manual Flush button.

e Gate Height button On the Spinner Spreading Run screen the Gate opening button sets the current value of the gate opening.

f Implement Switch Status Green arrow down – The implement is lowered. Red arrow up – The implement is raised.

g Increase/Decrease buttons Increases and decreases the application rate by the amount specified during setup.

h Logging button Green – Logging enabled. Gray – Logging disabled.

i Engage button Green – Auto guidance engaged. Gray – Auto guidance can be engaged. Red – Auto guidance cannot be engaged.

j Field-IQ Status tab Shows the engage status of each row on the implement. Green – Engaged. Gray – Section closed due to overlap. Red – Not engaged / Section manually turned off.

j

c

def

g

h

i

Page 3: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

3

SEttinG uP thE FiELd-iq PLuGin

before startingBefore configuring the Field-IQ plugin setup on the FmX integrated display, ensure that:• All components of the system are installed on the vehicle and

implement.• The Field-IQ plugin has been added to the FmX integrated

display configuration. From the Home screen, tap the Run icon. Next to Implement, tap edit. The Configuration screen appears. Ensure that the Field-IQ icon appears in the list. If the icon does not appear tap add/remove to add the plugin to the configuration.

• The implement setup has the correct option selected. From the Home screen, tap the Run icon. Next to Implement, tap edit. The Configuration screen appears. Select the implement from the list on the left and then tap setup. The Implement Setup screen appears. In the Operations tab, select the correct option:

– For Liquid, select the Liquid option. – For Granular Fertilizer, select the Granular Fertilizer option. – For Anhydrous, select the Anhydrous option.

Tap oK.Note: For additional information on settings, select the help icon in the top right hand corner of the screen.

Features tab Select the following:1. Application Type.2. Section Switching:

On: Automatic Section Control is active. Off: Automatic Section Control is not active.

3. Rate Control:On: Rate Control is active. Off: Rate Control is not active.

4. Implement Lift:Enabled: Implement switch controls coverage logging. Disabled: Implement switch is not used.

5. Anhydrous Units:When Anhydrous is selected for the application type, select the units that you want to control the rate by. Select either Lbs Actual N or Lbs NH3.

boom tab1. Section Control Type:

Air Clutch: Using Tru Count Air Clutches® valves.Electric Clutch: Using Tru Count electric section clutches.Boom Valve: Using standard polarity boom valves.Reverse Polarity: Using reverse polarity boom valves.

Caution – seleCting the inCorreCt value Causes the systeM to operate opposite of the required result.

2. Sections Off When Stopped: Yes: Turns off sections when the GPS speed is zero (recommended). No: Sections remian active when the GPS speed is zero.

3. On Latency: Default value is 0.0 seconds. Increase the On Latency value to compensate for mechanical delay in the system (more common for larger systems).

4. Off Latency: Default value is 0.0 seconds. Increase the Off Latency value to compensate for mechanical delay in the system (more common for larger systems).

Page 4: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

4

rate tabThe Rate tab is only visible if you have at least one Field-IQ Rate and Section Control Module installed.1. Rate 1 and Rate 2 fields:

Enter the rate to be used when the Rate Switch on the Field-IQ Master Switch box is in the Rate 1 or Rate 2 position.

2. Rate Adjust field: Increment to be used each time you press the Increment/Decrement switch on the Master Switch Box or display.

3. Rate Snapping list: Enabled: Shows the applied rate the same as the target rate (if the applied rate is within 10% of the target rate). Disabled: Shows the actual applied value.

4. Total Nozzles:Enter the total number of nozzles on the applicator (do not include fence row nozzles).

tank/bin tabThe Tank/Bin tab is only visible if at least one Field-IQ Rawson™ or Rate and Section control module is installed. Select the following:1. Tank/Bin Capacity:

Total tank/bin capacity.2. Warning Level:

Level at which you will receive notification when the capacity level drops below the assigned value.

3. Current Volume: Current volume of the tank/bin.

tips – Tap Refill Tank/Bin to set the current volume to the tank/

bin capacity. – Tap Manual Flush to open the control valve and allow the

system to operate at a preset speed. Use this feature to flush the booms or prime the system.

hardware tab

note – The numbers beneath each switch are the number of sections assigned to the switch. In this example, switch 1 controls rows 1 through 2, switch 2 controls rows 3 through 4, and so on. The numbers are assigned automatically and cannot be changed. If you are use the optional 12 section switch box, you will see 12 instead of 6 switches.1. Adjust the width value for each rate control module by tapping

the Width box and entering the appropriate value.2. To adjust the sections value for each section control module, tap

the Sections box. Enter the appropriate value and then tap oK.3. Verify that the serial numbers of the modules match the order

that the modules are mounted on the implement.

Sections tab1. Enter the number of rows controlled for each section.2. If the implement has more than 12 sections, use the buttons

below the 12 section fields to scroll to the other sections.

Override tab1. Jump Start Speed:

Controls the speed to be used when the Master switch is put in the jump start position.

2. Minimum Override Speed:This setting maintains the application rate when the actual speed drops below the value entered. It is used to ensure consistent material flow during slow speeds that may reach the physical limitations of the system.

Page 5: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

5

Granular and Liquid Calibrationwarning – there are Moving parts during this operation. ensure that the iMpleMent is safe to operate.

The Field-IQ Calibrate option only appears on the Configuration screen if you have at least one Field-IQ Rate and Section Control Module installed.1. From the Configuration screen, select the Field-IQ plugin and

then press Calibrate.2. From the Field-IQ Calibration screen, select the Rate and Section

Control Module to be calibrated.3. Select Valve Calibration.4. Select Valve Type, Plumbing, Valve Behavior on Sections Closed,

Auxiliary Valve, and Pump Disarming Switch.

5. Select the Control tab.6. Adjust the Allowable Error, Gain, and Minimum Response for

optimal system performance.

Granular System Calibrationselect flow Calibration1. In the Calibrate tab, enter the Gate Height setting and the

Shaft Encoder constant. 2. Press Calculate and then enter the Gate Width and Drag Chain

Distance traveled per Rev. 3. Select the Limit tab to set the maximum and minimum RPM. 4. Select the Info tab to verify the speeds that the system is

capable of reaching. 5. Return to the Calibrate tab and press Calibrate. 6. Enter the Amount of material you want to disperse, the Target

Rate, and Target Speed and then press Start.7. Run the calibration and then enter the actual amount of

material dispensed.

select gate height Calibration1. If there is a Gate Height sensor connected to the Field-IQ

system, select Yes in the Enabled menu, then select Run Calibration.

2. Follow the on-screen instructions to complete the calibration.

Liquid Calibrationselect flow Calibration1. Set the Flow Meter Type, Flow Meter Calibration, and Minimum

Flow values. 2. Press Run Calibration.3. Set the Target Rate and Speed and then press Next. 4. Follow the on-screen instructions to complete the calibration.select pressure Calibration1. Select the pressure sensor to be calibrated and enable it.2. Enter the appropriate name and then press Run Calibration. 3. Follow the on-screen instructions to complete the calibration. 4. Repeat Step 1 through Step 3 for the second pressure sensor if

one is connected.

Configuring the OEM switch interface1. From the Configuration screen, highlight the OEM Switch

Interface and then select Setup.2. Activate the switch on the OEM console that you want to

configure. This highlights the input on the left side of the screen that the switch is connected to.

3. From the right-hand side of the screen, select the action to assign to the switch.

4. Repeat Step 1 through Step 3 for all switches to be assigned.

CaLibratinG thE GranuLar Or Liquid SyStEM

Page 6: AgGPS FmX Integrated Display with the Field-IQ Crop Input ... · with the Field-IQ™ Crop Input Control System Quick Reference Card ... For more information on system calibration

P/N 93020-88-E03

6

© 2010. Trimble Navigation Limited. All rights reserved. Trimble, the Globe and Triangle logo, AgGPS, FmX, and Tru Count Air Clutch are trademarks of Trimble Navigation Limited, registered in the United States and in other countries. Field-IQ is a trademark of Trimble Navigation Limited. Version 3.00, Rev C (September 2010).*93020-88-E03*

with the Field-IQ™ Crop Input Control SystemQuick Reference Card

CaLibratinG thE rawSOn MOduLES

PLantEr CaLibratiOnThe Field-IQ Calibrate option only appears on the Configuration screen if you have at least one Field-IQ Rawson control module installed.1. From the Configuration screen, select the Field-IQ plugin and

then tap Calibrate.2. From the Field-IQ Calibration screen, select the Rawson Control

Module to be calibrated.3. In the Seeds Per Disk field, enter a value.4. Enter a value in the Gear Ratio field or tap Calculate.5. Use the Gear Ratio Calculator to determine the planter drive

gear ratio and then tap oK. The Calibration Constant field contains a calculated value that the system determines during calibration. To start out, Trimble recommends that you leave the value at 1.000. After the calibration test, the system may adjust this number.

6. Place a clean empty container under the rows that contain seeds to capture the seeds dispensed during the calibration.

warning – Moving parts during this operation. ensure that the iMpleMent is safe to operate.

7. Tap test.8. In the Number of Seed Meter Revolutions field, enter a value

and then tap Start. The higher the number of revolutions the more accurate the calibration. Trimble recommends 5 to 10 revolutions.

9. Follow the on-screen prompts of operating the master switch. After the system turns the specified number of revolutions, enter the number of seeds dispensed per row and then tap Continue.

10. The next screen shows the minimum and maximum speeds for the target rate specified. Tap oK and then either press Test to repeat the calibration or tap oK to continue.

11. Tap oK.Repeat Step 1 through Step 9 for other Rawson Control Modules that need calibration.