I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
ALUMBRADO DE TÚNELESNORMAS Y CRITERIOS
![Page 2: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/2.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
INTRODUCCIÓN
DESLUMBRAMIENTO ¡¡¡¡
![Page 3: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/3.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
Contraste de Luminancia
Contraste negativo (C < 0)(Obstaculo mas oscuro que el fondo)
Contraste positivo (C > 0)(Obstaculo mas brillante que el fondo)
![Page 4: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/4.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
Positive or negative contrast
![Page 5: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/5.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SECCION TIPICA TUNEL UNIDIRECCIONAL
TransitionTransitionzonezone
ThThzonezone
Access zoneAccess zone InteriorInteriorzonezone
ExitExitzonezone
PortalPortal
TunnelTunnelLengthLength
ExitExit
DirectionDirectionof trafficof traffic
TresholdTresholdzonezone
AccessAccesszonezone
TransitionTransitionzonezone
InteriorInteriorzonezone
ExitExitzonezone
LL2020
LLthth
LLtrtrLLinin
LLexex
SSDSSD
Lum
inan
ceLu
min
ance
![Page 6: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/6.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
Para el diseño hay que tener el valorde luminancia de umbral Lth
• Lth = Valor de Luminancia en la primera mital de ladistancia de parada(SSD).
• El diseñador debe entregar el valor L 20 (valor deluminancia en el exterior del túnel) o en su defecto seutiliza alguno de los dos métodos citados en lanorma CIE 88 de 2004 “Guide for the lighting of roadTunnels and Underpassed” para hallar éste valor yasí determinar el (Lth).
![Page 7: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/7.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
L20 method
Speed (km/h)
≤60 km/h80 km/h
120 km/h
k = Lth / L20
0.050.060.10
CIE 88CIE 8820042004**
**CEN TR: L20 CEN TR: L20 methodologymethodology
No difference betweenNo difference betweenSYM and CBLSYM and CBL
System!System!
!
!!!
![Page 8: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/8.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
TRANSITION ZONESTRANSITION ZONES80 km/h80 km/h
0.5 SD 0.5 SD LLthth
2 x Linterior (!)
(s)THRESHOLDTHRESHOLDZONEZONE
stopping dist.stopping dist.
DIAGRAMA DE NIVEL DE LUMINANCIA ALO LARGO DE VARIAS ZONAS
![Page 9: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/9.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
S t o p p i n gDistance(m)
LONG TUNNELSTraffic flow
Low Heavy160m60m
63
106
Luminance values in cd/m² in theinterior zone (long tunnels)
![Page 10: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/10.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
Traffic flow classificationCIE 88 - 2004
Traffic flow *One Way
TrafficTwo way
traffic
High > 1500 > 400
Low < 500 < 100
**peakpeak hourhour traffictraffic, , vehiclesvehicles per per hourhour per per lanelane
![Page 11: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/11.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
Luminance values in cd/m²in the second part of the interior zone
-very long tunnels
S t o p p i n gDistance(m)
VERY LONG TUNNELSTraffic flow
Low Heavy160m60m
2,51
4,52
![Page 12: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/12.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SISTEMA DE ILUMINACIÓN SIMÉTRICO
EEvv LLbb
LLbb
EEvv≤≤ 0.2 0.2
![Page 13: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/13.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SISTEMA DE ILUMINACIÓN SIMETRICO
![Page 14: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/14.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SISTEMA DE ILUMINACION COUNTER BEAM(C.B.L.)
LLbb
EEvv 0.6 0.6≥≥
EEvv LLbb
![Page 15: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/15.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
LOS OBSTACULOS SE VUELVENVISIBLES POR CONTRASTE
NEGATIVO
Counter Beam Lighting (C.B.L.)
![Page 16: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/16.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SISTEMA DE ILUMINACIÓN COUNTER BEAM (C.B.L.)
![Page 17: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/17.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
SISTEMA DE ILUMINACIÓN COUNTER BEAM (C.B.L.)
![Page 18: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/18.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
The Range > Aluminium > Fixed Length > AF4
Up to HPS 600W!
For interior sectionororFor reinforcement (symetrical and
counter beam)
Alu – glass
IP66
HPS(◊1x600W – 2x150W)Fluo-compact(◊2x36W)Induction
L = 560 mmW = 500 mmD = 180 mm
AF4
AF4
![Page 19: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/19.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
TUNELES BUENAVISTA Y BIJAGUALVIA BOGOTÁ – VILLAVICENCIO
COLOMBIA
![Page 20: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/20.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
TUNEL DE OCCIDENTE – SALIDA DE MEDELLIN-ANTIOQUIACOLOMBIA
![Page 21: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/21.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
TUN
EL
DE
OC
CID
EN
TES
ALI
DA
DE
ME
DE
LLIN
-AN
TIO
QU
IAC
OLO
MB
IA
![Page 22: ALUMBRADO DE TÚNELES NORMAS Y CRITERIOS](https://reader034.vdocuments.net/reader034/viewer/2022051219/5695d3ab1a28ab9b029ec080/html5/thumbnails/22.jpg)
I SEMINARIO NACIONAL DE ALUMBRADO PUBLICO CODELECTRA 2007
MUCHAS GRACIAS