aluminum conductor, compressed hard-drawn, ec-1350 · pdf filecondumex vulcanel cable ......
TRANSCRIPT
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils EPR Insulation
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
Aluminum Conductor, CompressedHard-drawn, EC-1350 Alloy
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
14
14
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.69
0.73
0.77
0.82
0.87
0.93
0.75
0.80
0.84
0.88
0.93
0.99
0.88
0.93
0.97
1.01
1.10
1.15
0.98
1.03
1.07
1.11
1.20
1.26
62.2
79.0
98.8
124.6
157.5
198.2
132.1
172.0
212.0
273.0
338.0
425.0
455
536
615
732
848
1009
518
600
680
810
927
1090
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
14
12
12
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.69
0.73
0.77
0.82
0.87
0.93
0.99
1.09
1.22
1.41
1.57
0.75
0.80
0.84
0.88
0.93
0.99
1.05
1.19
1.33
1.52
1.71
0.88
0.93
0.97
1.01
1.10
1.13
1.17
1.36
1.49
1.72
1.92
0.98
1.03
1.07
1.11
1.20
1.23
1.27
1.46
1.59
1.89
2.03
62.2
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.3
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
403
443
482
552
630
737
849
1111
1442
1959
2524
466
507
547
630
709
818
959
1253
1590
2149
2727
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils EPR Insulation
Hard-drawn, EC-1350 Alloy
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
14
14
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.78
0.83
0.87
0.91
0.96
1.02
0.84
0.89
0.93
0.98
1.03
1.12
0.97
1.02
1.06
1.10
1.19
1.29
1.075
1.121
1.161
1.207
1.291
1.386
62.2
79.0
98.8
124.6
157.5
198.2
132.1
172.0
212.0
273.0
338.0
425.0
534
606
691
808
926
1135
603
676
764
895
1015
1228
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
14
12
12
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.78
0.83
0.87
0.91
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.98
1.03
1.12
1.18
1.29
1.42
1.61
1.81
0.97
1.02
1.06
1.10
1.19
1.27
1.37
1.45
1.58
1.81
2.01
1.075
1.121
1.161
1.207
1.291
1.369
1.469
1.552
1.746
1.980
2.175
62.2
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.3
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
482
513
558
628
708
863
978
1219
1555
2144
2667
551
583
631
715
797
956
1092
1369
1715
2349
2882
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation
Hard-drawn, EC-1350 Alloy
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.91
0.95
0.99
1.04
1.10
1.16
1.26
1.40
1.59
1.74
0.97
1.01
1.06
1.15
1.21
1.26
1.40
1.50
1.73
1.89
1.10
1.14
1.19
1.31
1.37
1.47
1.53
1.66
1.94
2.09
1.20
1.24
1.29
1.41
1.47
1.57
1.70
1.83
2.10
2.26
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
583
629
706
820
961
1086
1328
1681
2294
2827
664
712
806
923
1068
1229
1500
1865
2528
3072
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
12
12
10
10
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
19 wire
13
16
13
16
20
14
14
12
12
12
0.33
0.37
0.42
0.47
0.53
0.91
0.95
0.99
1.04
1.10
0.97
1.01
1.06
1.15
1.21
1.10
1.14
1.19
1.31
1.37
1.20
1.24
1.29
1.41
1.47
79.0
96.8
124.6
157.5
198.2
172.0
212.0
273.0
338.0
425.0
676
762
886
1038
1233
757
845
986
1141
1340
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils EPR Insulation
Hard-drawn, EC-1350 Alloy
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
16
13
16
20
14
12
12
12
0.37
0.42
0.47
0.53
1.12
1.17
1.22
1.26
1.23
1.27
1.32
1.38
1.35
1.40
1.48
1.54
1.46
1.50
1.59
1.71
98.8
124.6
157.5
198.2
212.0
273.0
338.0
425.0
968
1105
1236
1433
1068
1224
1356
1558
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
835
925
1018
1161
1301
1558
2003
2590
3143
935
10444
1138
1286
1484
1752
2213
2850
3415
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
1.12
1.17
1.22
1.28
1.33
1.44
1.57
1.76
1.92
1.23
1.27
1.32
1.38
1.44
1.54
1.72
1.93
2.06
1.35
1.40
1.48
1.54
1.64
1.70
1.88
2.11
2.27
1.46
1.50
1.59
1.71
1.81
1.89
2.04
2.28
2.43
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
13
11
16
15
20
14
14
14
14
14
12
12
10
10
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
14
11
13
12
17
25
33
14
14
14
14
14
12
12
10
10
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.69
0.73
0.77
0.82
0.87
0.93
0.99
1.09
1.22
1.41
1.57
0.75
0.80
0.84
0.88
0.93
0.99
1.05
1.19
1.33
1.52
1.71
0.88
0.93
0.97
1.01
1.10
1.15
1.19
1.36
1.49
1.72
1.92
0.98
1.03
1.07
1.11
1.20
1.25
129
1.46
1.59
1.89
2.03
204.9
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
79.3
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
545
636
749
891
1056
1267
1487
2022
2712
3873
5028
608
700
814
969
1135
1348
1597
2164
2860
4063
5231
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils EPR Insulation
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
12
12
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.69
0.73
0.77
0.82
0.87
0.93
0.75
0.80
0.84
0.88
0.93
0.99
0.88
0.93
0.97
1.01
1.10
1.15
0.98
1.03
1.07
1.11
1.20
1.26
204.9
258.4
325.8
410.9
518.1
653.3
210.9
267.8
330.3
421.4
527.9
663.3
677
811
960
1116
1398
170
740
875
1025
1244
1477
1784
Copper Conductor, CompressedSoft-drawn, Bare
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils EPR Insulation
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
Copper Conductor, CompressedSoft-drawn, Bare
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
12
12
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.78
0.83
0.87
0.91
0.96
1.02
0.84
0.89
0.93
0.96
1.03
1.12
0.97
1.04
1.08
1.10
1.19
1.29
1.075
1.141
1.181
1.207
1.291
1.389
204.9
258.4
325.8
410.9
518.1
653.3
210.9
267.8
330.3
421.4
527.9
663.3
756
881
1036
1242
1476
1829
825
951
1109
1329
1565
1922
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
14
11
13
12
17
25
33
14
14
14
14
14
12
12
10
10
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.78
0.83
0.87
0.91
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.98
1.03
1.12
1.18
1.29
1.42
1.61
1.81
0.97
1.04
1.08
1.10
1.19
1.31
1.41
1.49
1.62
1.81
2.01
1.075
204.9
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
79.3
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
624
706
825
967
1134
1393
1616
2130
2825
4058
5171
693
776
898
1054
1223
1486
1730
2280
2985
4263
5386
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
Copper Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation
Soft-drawn, Bare
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.91
0.95
0.99
1.04
1.10
1.16
1.26
1.40
1.59
1.74
0.97
1.01
1.06
1.15
1.21
1.26
1.40
1.50
1.73
1.89
1.10
1.14
1.19
1.31
1.39
1.49
1.57
1.70
1.94
2.09
1.20
1.24
1.29
1.41
1.47
1.59
1.74
1.87
2.10
2.26
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
776
896
1045
1246
1491
1724
2239
2951
4208
5331
859
996
1148
1353
1634
1896
2423
3185
4453
5331
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
7
9
11
14
11
13
12
17
25
33
14
14
14
14
12
12
10
10
10
10
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
19 wire
13
16
20
25
32
12
12
12
12
12
0.33
0.37
0.42
0.47
0.53
0.91
0.95
0.99
1.04
1.10
0.97
1.01
1.06
1.15
1.21
1.10
1.16
1.19
1.31
1.37
1.20
1.26
1.29
1.41
1.47
258.4
325.8
410.9
518.1
653.3
267.8
330.3
421.4
527.9
663.3
951
1107
1320
1588
1927
1032
1190
1420
1691
2034
Copper Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils EPR Insulation
Soft-drawn, Bare
eliminating unequal electrical stress.
loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Ethylene Propylene Rubber (EPR) insulation offers: excellent heat, moisture and corona resistance; electrical stability under stress; low dielectric
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
16
20
25
32
12
12
12
12
0.37
0.42
0.47
0.53
1.12
1.17
1.22
1.28
1.23
1.27
1.32
1.38
1.35
1.40
1.48
1.54
1.46
1.50
1.59
1.71
325.8
410.9
518.1
653.3
330.3
421.4
517.9
663.3
1313
1539
1786
2127
1413
1658
1906
2252
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
1102
1264
1444
1691
1939
2469
3273
4504
5647
1221
1384
1569
1874
2133
2679
3533
4776
-
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
1.12
1.17
1.22
1.28
1.33
1.44
1.57
1.76
1.92
1.23
1.27
1.32
1.38
1.44
1.54
1.72
1.93
2.06
1.35
1.40
1.48
1.54
1.64
1.70
1.88
2.11
2.27
1.46
1.50
1.59
1.71
1.81
1.89
2.04
2.28
2.43
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
9
11
14
11
13
12
17
25
33
14
14
14
12
12
10
10
10
10
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils TR-XLP Insulation
Hard-drawn, EC-1350 Alloy
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
14
14
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.69
0.73
0.77
0.82
0.87
0.93
0.75
0.80
0.84
0.88
0.93
0.99
0.88
0.93
0.97
1.01
1.10
1.15
0.98
1.03
1.07
1.11
1.20
1.26
62.2
79.0
98.8
124.6
157.5
198.2
132.1
172.0
212.0
273.0
338.0
425.0
379
452
528
627
752
904
496
571
650
750
902
1055
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
14
12
12
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.69
0.73
0.77
0.82
0.87
0.93
0.99
1.09
1.22
1.41
1.57
0.75
0.80
0.84
0.88
0.93
0.99
1.05
1.19
1.33
1.52
1.71
0.88
0.93
0.97
1.01
1.10
1.13
1.17
1.36
1.49
1.72
1.92
0.98
1.03
1.07
1.11
1.20
1.23
1.27
1.46
1.59
1.89
2.03
62.2
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.3
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
326
359
396
447
534
631
728
966
1230
1716
2246
445
480
521
573
689
788
939
1241
1521
2091
2558
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils TR-XLP Insulation
Hard-drawn, EC-1350 Alloy
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
14
14
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.78
0.83
0.87
0.91
0.96
1.02
0.84
0.89
0.93
0.98
1.03
1.12
0.97
1.02
1.06
1.10
1.19
1.29
1.075
1.121
1.161
1.207
1.291
1.386
62.2
79.0
98.8
124.6
157.5
198.2
132.1
172.0
212.0
273.0
338.0
425.0
426
495
570
680
801
950
560
631
707
822
966
1123
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
14
12
12
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.78
0.83
0.87
0.91
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.98
1.03
1.12
1.18
1.29
1.42
1.61
1.81
0.97
1.02
1.06
1.10
1.19
1.27
1.37
1.45
1.58
1.81
2.01
1.075
1.121
1.161
1.207
1.291
1.369
1.469
1.552
1.746
1.980
2.175
62.2
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.3
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
373
402
438
583
622
677
795
1002
1298
1796
2325
509
541
579
752
767
855
1027
1282
1616
2266
2772
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils EPR Insulation
Hard-drawn, EC-1350 Alloy
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.91
0.95
0.99
1.04
1.10
1.16
1.26
1.40
1.59
1.74
0.97
1.01
1.06
1.15
1.21
1.26
1.40
1.50
1.73
1.89
1.10
1.14
1.19
1.31
1.37
1.47
1.53
1.66
1.94
2.09
1.20
1.24
1.29
1.41
1.47
1.57
1.70
1.83
2.10
2.26
79.0
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.4
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
466
508
560
683
799
994
1090
1380
1933
2422
615
656
715
865
988
1247
1377
1690
2321
2833
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
6
7
9
11
13
11
16
15
20
14
14
14
14
14
14
12
12
10
10
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
19 wire
13
16
13
16
20
14
14
12
12
12
0.33
0.37
0.42
0.47
0.53
0.91
0.95
0.99
1.04
1.10
0.97
1.01
1.06
1.15
1.21
1.10
1.14
1.19
1.31
1.37
1.20
1.24
1.29
1.41
1.47
79.0
96.8
124.6
157.5
198.2
172.0
212.0
273.0
338.0
425.0
558
639
740
901
1070
704
787
890
1076
1253
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
Aluminum Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils TR-XLP Insulation
Hard-drawn, EC-1350 Alloy
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
16
13
16
20
14
12
12
12
0.37
0.42
0.47
0.53
1.12
1.17
1.22
1.26
1.23
1.27
1.32
1.38
1.35
1.40
1.48
1.54
1.46
1.50
1.59
1.71
98.8
124.6
157.5
198.2
212.0
273.0
338.0
425.0
775
902
1031
1196
966
1123
1257
1453
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
98.8
124.6
157.5
198.2
234.5
327.9
468.3
702.5
936.8
79.5
93.1
120.2
152.4
181.0
240.0
350.0
501.7
705.6
644
751
817
824
1031
1247
1636
2157
2763
839
982
1051
1190
1338
1615
2050
2669
3184
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
1.12
1.17
1.22
1.28
1.33
1.44
1.57
1.76
1.92
1.23
1.27
1.32
1.38
1.44
1.54
1.72
1.93
2.06
1.35
1.40
1.48
1.54
1.64
1.70
1.88
2.11
2.27
1.46
1.50
1.59
1.71
1.81
1.89
2.04
2.28
2.43
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
13
11
16
15
20
14
14
14
14
14
12
12
10
10
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Aluminum conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 100% Insulation Level175 Mils TR-XLP Insulation
Copper Conductor, CompressedSoft-drawn, Bare
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
12
12
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.69
0.73
0.77
0.82
0.87
0.93
0.75
0.80
0.84
0.88
0.93
0.99
0.88
0.93
0.97
1.01
1.10
1.15
0.98
1.03
1.07
1.11
1.20
1.26
204.9
258.4
325.8
410.9
518.1
653.3
210.9
267.8
330.3
421.4
527.9
663.3
514
654
937
1124
1358
1662
580
715
1011
1192
1430
1730
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Copper conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
14
11
13
12
17
25
33
14
14
14
14
14
12
12
10
10
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.69
0.73
0.77
0.82
0.87
0.93
0.99
1.09
1.22
1.41
1.57
0.75
0.80
0.84
0.88
0.93
0.99
1.05
1.19
1.33
1.52
1.71
0.88
0.93
0.97
1.01
1.10
1.15
1.19
1.36
1.49
1.72
1.92
0.98
1.03
1.07
1.11
1.20
1.25
129
1.46
1.59
1.89
2.03
204.9
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
79.3
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
383
479
710
846
1016
1228
1433
1915
2683
3855
5007
451
542
788
917
1090
1311
1555
2070
2847
4031
5193
Copper Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 15 KV 133% Insulation Level220 Mils TR-XLP Insulation
Soft-drawn, Bare
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
10
13
16
20
16
20
14
12
12
12
12
12
0.29
0.33
0.37
0.42
0.47
0.53
0.78
0.83
0.87
0.91
0.96
1.02
0.84
0.89
0.93
0.96
1.03
1.12
0.97
1.04
1.08
1.10
1.19
1.29
1.075
1.141
1.181
1.207
1.291
1.389
204.9
258.4
325.8
410.9
518.1
653.3
210.9
267.8
330.3
421.4
527.9
663.3
564
701
988
1177
1405
1754
633
772
1069
1257
1486
1836
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
2
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
7 wire
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
6
7
9
11
14
11
13
12
17
25
33
14
14
14
14
14
12
12
10
10
10
10
0.29
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.78
0.83
0.87
0.91
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.96
1.02
1.08
1.18
1.31
1.51
1.66
0.84
0.89
0.93
0.98
1.03
1.12
1.18
1.29
1.42
1.61
1.81
0.97
1.04
1.08
1.10
1.19
1.31
1.41
1.49
1.62
1.81
2.01
1.075
204.9
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
79.3
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
433
526
778
903
1065
1320
1564
2009
2781
3998
5112
504
600
863
986
1150
1407
1700
2174
2959
4196
5310
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Copper conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
Copper Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 25 KV 100% Insulation Level260 Mils TR-XLP Insulation
Soft-drawn, Bare
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
0.33
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
0.91
0.95
0.99
1.04
1.10
1.16
1.26
1.40
1.59
1.74
0.97
1.01
1.06
1.15
1.21
1.26
1.40
1.50
1.73
1.89
1.10
1.14
1.19
1.31
1.39
1.49
1.57
1.70
1.94
2.09
1.20
1.24
1.29
1.41
1.47
1.59
1.74
1.87
2.10
2.26
258.4
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
92.6
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
659
775
900
1180
1330
1633
2002
2650
3847
4926
808
923
1055
1292
1519
1886
2289
2960
4235
5337
1
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
7
9
11
14
11
13
12
17
25
33
14
14
14
14
12
12
10
10
10
10
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
19 wire
13
16
20
25
32
12
12
12
12
12
0.33
0.37
0.42
0.47
0.53
0.91
0.95
0.99
1.04
1.10
0.97
1.01
1.06
1.15
1.21
1.10
1.16
1.19
1.31
1.37
1.20
1.26
1.29
1.41
1.47
258.4
325.8
410.9
518.1
653.3
267.8
330.3
421.4
527.9
663.3
834
987
1175
1452
1764
980
1135
1325
1627
1947
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Copper conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical
Copper Conductor, Compressed
CONDUMEX VULCANEL CABLEPrimary URD 35 KV 100% Insulation Level345 Mils TR-XLP Insulation
Soft-drawn, Bare
ConductorAWG or
MCM
Copper Neutral (Full) Diameter (Inches) Weight (Pounds)
Stranding Conductor ConductorSize
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
1/0
2/0
3/0
4/0
19 wire
19 wire
19 wire
19 wire
16
20
25
32
12
12
12
12
0.37
0.42
0.47
0.53
1.12
1.17
1.22
1.28
1.23
1.27
1.32
1.38
1.35
1.40
1.48
1.54
1.46
1.50
1.59
1.71
325.8
410.9
518.1
653.3
330.3
421.4
517.9
663.3
834
987
1175
1452
1764
980
1135
1325
Conductor Copper Neutral (1/3) Diameter (Inches) Weight (Pounds)
AWG or
MCMStranding Conductor Conductor
Size
AWG (Solid)
Number of
Wires
Over
Insulation
Over Neutral
Wires
Over Insul.
Shield
Over
Encaps. Jkt.
Concentric
Neutral
Total
No Jacket
Total With
Jacket
325.8
410.9
518.1
653.3
771.9
1081
1544
2316
3088
119.2
146.3
185.9
228.0
282.1
398.0
543.5
801.5
1058
659
775
900
1110
1330
1633
2002
2650
3847
4926
808
923
1055
1292
1519
1886
2289
2960
0.37
0.42
0.47
0.53
0.57
0.68
0.81
0.99
1.14
1.12
1.17
1.22
1.28
1.33
1.44
1.57
1.76
1.92
1.23
1.27
1.32
1.38
1.44
1.54
1.72
1.93
2.06
1.35
1.40
1.48
1.54
1.64
1.70
1.88
2.11
2.27
1.46
1.50
1.59
1.71
1.81
1.89
2.04
2.28
2.43
1/0
2/0
3/0
4/0
250
350
500
750
1000
19 wire
19 wire
19 wire
19 wire
37 wire
37 wire
37 wire
61 wire
61 wire
9
11
14
11
13
12
17
25
33
14
14
14
12
12
10
10
10
10
eliminating unequal electrical stress.
stability under stress; low dielectric loss, chemical resistance.
Specifications:
Copper conductors are also available strand-filled.
ICEA S-94-649; AEIC CS 8
Short Circuit - 250 CO
Dimensions and weights are nominal, and subject to standard industry tolerances.
Normal Operation - 90 C; Emergency Overload - 130 CO O
Medium voltage power cable for single phase underground distribution (UD), including getaway systems in low profile substations.
1. Simultaneous extrusion of strand shield, insulation, and insulation shield (triple extrusion, dry curing process) forms a virtually perfect cable core,
Maximum Conductor
Temperatures:
Application:
Features:
2. Tree-retardant Cross-Link Polyethylene Ethylene Propylene Rubber (TR-XLP) insulation offers: excellent heat, moisture and corona resistance; electrical