27 w pd 3.0 / qc 4.0 + / pps ld5763 & ld8523 & ld6610
Post on 02-Dec-2021
4 Views
Preview:
TRANSCRIPT
Innovation Service Quality Sharing
創新 服務 品質 共享
Date:2018/04/25
27 W
PD 3.0 / QC 4.0 + / PPS
LD5763 & LD8523 & LD6610
By:Chris Pai
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
Contents
1. Specification
2. Outline
3. Schematic
4. PCB Layout
5. Bill of Materials
6. Transformer Design
7. Efficiency
8. No Load Power Consumption
9. Output Voltage Transition
10. Line / Load / Cross Regulation
11. Constant Current
12. Over Current Protection
13. Over Voltage Protection
14. Ripple & Noise Voltage
15. Dynamic Load
16. Turn-on Delay Time
17. Hold-up Time
18. Rise Time & Overshoot
19. AC Brown-in
20. AC Brown-out
21. Supply Voltage of IC
22. Stress on Switching Parts
23. Flux Density of Transformer
24. EMI
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
1. Specification
Item Min. Typ. Max. Test Result
Input Voltage ( VAC ) 90 115 230 264
Input Frequency ( Hz ) 47 60 50 63
Output
Voltage &
Current
( V / A )
PD 3.0 Mode 5 / 3 9 / 3
PPS Mode 3.3 / 3 5 / 3 9 / 3 11 / 2.45
QC 3.0 Mode 3.6 / 3 5 / 3 9 / 3 12 / 2.25
QC 2.0 Mode 5 / 3 9 / 3 12 / 2.25
Efficiency CoC Tier 2 Pass
Standby Power ( mW ) < 30 @ 115 VAC / < 75 @ 230 VAC Pass
Output Voltage Accuracy ( % ) < ± 5 ( for PD 3.0 Mode ) Pass
Constant Current Accuracy ( mA
) < ± 150 ( for PPS Mode ) Pass
Over Current Protection ( % ) < 130 Pass
Over Voltage Protection ( V ) < 4.95 ( for 3.3 V ) / < 7.5 ( for 5 V ) / < 13.5 ( for 9 V ) / < 16 ( for
12 V ) Pass
Ripple & Noise Voltage ( mV ) < 80 Pass
Dynamic Load ( % ) < ± 10 of VBUS,SET Pass
Turn-on Delay Time ( S ) < 1 Pass
Hold-up Time ( mS ) > 10 @ Typical AC Input Pass
Rise Time ( mS ) < 5 Pass
Overshoot ( % ) < 10 Pass
AC Brown-in ( VAC ) < 85 Pass
AC Brown-out ( VAC ) < 85 Pass
EMI EN55032 Class B Pass
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
2. Outline
Bottom View Top View
36 mm
Side View
48 mm
Rear View
21 mm
LD5763
LD6610
LD8523
12.2 W / inch3
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
3. Schematic
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
4. PCB Layout
Bottom Side Top Side
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
5. Bill of Materials Location Description Q’ty
NTC1 SCK08053MSY / 5 Ω / 3 A / M / 8 Φ 1
R2,R20 200 kΩ / J / 1206 2
R3 56 Ω / J / 1206 1
R4 20 kΩ / J / 1206 1
R5 22 Ω / J / 0603 1
R6 0 Ω / J / 0805 1
R7 330 kΩ / F / 0805 1
R8 21.5 kΩ / F / 0603 1
R9 220 Ω / J / 0603 1
R10,R23,R28 10 kΩ / J / 0603 3
R11,R12,R13 1.6 Ω / F / 1206 3
R14 20 Ω / J / 1206 1
R15 20 kΩ / J / 0603 1
R16 2.2 Ω / J / 0603 1
R17 100 Ω / J / 0603 1
R18 2 Ω / J / 0603 1
R19 4.7 kΩ / J / 0603 1
R21,R39 100 kΩ / J / 0603 2
R22 5 mΩ / F / 1206 1
R24,R25 1 kΩ / J / 0603 2
R26 91 kΩ / F / 0603 1
R27 13 kΩ / F / 0603 1
R29,R30,R31,R32 47 Ω / J / 0603 4
R33 12 kΩ / J / 0603 1
R35 0 Ω / J / 1206 1
R36 3.3 kΩ / J / 1206 1
CX1 0.1 μF ( 104 ) / 275V / HQX / X2 1
CY1 220 pF ( 221 ) / 250V / KX / Y1 1
C1,C2 22 μF / 400 V / SH / 10 x 16 mm 2
C3 1 nF ( 102 ) / 1 kV / X7R / 1206 1
C5,C6 4.7 μF ( 475 ) / 100 V / X7R / 1210 2
C7,C19,C20,C21,C2
2 330 pF ( 331 ) / 50 V / NPO / 0603 5
Location Description Q’ty
C8 100 pF ( 101 ) / 50V / NPO / 0603 1
C9 470 pF ( 471 ) / 1 kV / X7R / 1206 1
C10 1,000 μF / 16 V / FG / 8 x 15 mm 1
C11 470 μF / 16 V / FG / 6.3 x 11 mm 1
C12,C15 100 nF ( 104 ) / 50 V / X7R / 0603 2
C13 4.7 μF ( 475 ) / 10V / X5R / 0603 1
C14 100 nF ( 104 ) / 10 V / X7R / 0603 1
C16 10 nF ( 103 ) / 50 V / X7R / 0603 1
C17 2.2 nF ( 222 ) / 50 V / X7R / 0603 1
C18 22 nF ( 223 ) / 50 V / X7R / 0603 1
C23 1 μF ( 105 ) / 10 V / X7R / 0603 1
BD1 ABS210 / 1 kV / 2 A / ABS 1
D1 RS2MA / 1 kV / 2 A / SMA 1
D2,D3 RS1DL / 200 V / 1 A / SOD-123FL 2
ZD2 BZT52-C6V8(N) / 6.8V / 0.41W / SOD-123 1
Q1 SMK1065F / 680 V / 10 A / 0.85 Ω / TO-220F 1
Q2 AP9474GM-HF / 60 V / 12.8 A / 13 mΩ /
SOP-8 1
Q3 FDS6681Z / -30 V / -20 A / 6.5 mΩ / SOP-8 1
Q4 FMMT624TA / 125 V / 1A / SOT-23 1
U1 LD5763 / SOP-8 1
U2 EL1019 / 200 ~ 400 % / SOP-4 1
U3 LD8523 / SOT-26 1
U4 LD6610 / QFN-16 1
L1 T 8 x 4 x 3 / 67 μH / 0.3 mm x 12 T 1
L2 DR 6 x 8 / 100 μH / 0.26 mm x 60.5 T 1
T1 RM-8 / KP44A / 48 : 5 : 19 / 800 μH 1
F1 2 A / 250V / T / 2010 1
PCB ( Mother ) 48 x 36 mm / FR-4 / 2 oz 1
PCB ( Daughter ) 13 x 24.5 mm / FR-4 / 2 oz 1
Type C Type C Connector 1
CN1,CN3 Pitch = 2.54 mm ( 4 PIN ) Board Connector 1
CN2,CN4 Pitch = 2.54 mm ( 2 PIN ) Board Connector 1
Parts: 82 pcs
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
6. Transformer Design Schematic of Winding Construction of Winding
Winding No.
Pin No. Winding Types
Number of Turns Remarks
Start Finish Winding Tape
N1 1 F 0.32 mm X 1 25 2 NP1 Pin 朝機台順繞
N2 3 10 0.12 mm X 2 19 2
NA Pin 朝機台順繞 ( 3 線並繞 ) N3 10 X 0.12 mm X 1 Cancel
N4 A B 0.60 mm X 2 5 2 NS Pin 朝機台順繞
N5 10 X 0.12 mm X 3 19 2 Cancel Pin 朝機台順繞
N6 F 12 0.32 mm X 1 23 2 NP2 Pin 朝機台順繞
F 1 NP1 + NP2 扭結線
3 飛線 A 反折底部出線
Foil 10 5 mm X 10 mm X 1 mil Core 底部貼銅下地 Pin 10
Bottom View of Bobbin
Bobbin Shape
Core Material
Ae
( mm2 ) LP
( µH )
RM-8 KP44A 64 800 ± 5 %
@ 65 kHz / 1 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
7. Efficiency
Input Voltage 115 VAC / 60 Hz 230 VAC / 50 Hz
Output Current 100 %, 75 %, 50 %, 25 %, 10 % of Full Load
Measured Point of Output Voltage End of PCB
Duration of Burn-in 30 Minutes
Requirement CoC Tier 2
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
7. Efficiency ( Cont. ) VIN,AC
( V / Hz ) Mode
VBUS,SET
( V )
VBUS,PCB
( V )
IOUT
( A )
PBUS,PCB
( W )
PIN
( W )
η
( % )
ηAV,4-Points
( % )
Requirement
( % )
115 / 60
PD 3.0
5
5.0809 2.9940 15.212 17.373 87.562
88.705 > 81.84 5.0860 2.2440 11.413 12.770 89.373
5.0907 1.4960 7.616 8.517 89.417
5.0951 0.7480 3.811 4.308 88.466
5.0977 0.2960 1.509 1.787 84.439 > 72.48
9
9.1011 2.9940 27.249 30.535 89.238
89.684 > 87.30 9.1061 2.2440 20.434 22.607 90.388
9.1097 1.4960 13.628 15.140 90.014
9.1135 0.7480 6.817 7.651 89.098
9.1160 0.2960 2.698 3.190 84.587 > 77.30
PPS
3.3
3.3067 2.9510 9.758 11.356 85.929
87.398 > 78.93 3.3170 2.2460 7.450 8.444 88.228
3.3276 1.4980 4.985 5.645 88.304
3.3385 0.7480 2.497 2.866 87.132
3.3448 0.2960 0.990 1.176 84.189 > 69.66
11
11.1015 2.4110 26.766 29.706 90.102
89.405 > 87.30 11.1039 1.8410 20.442 22.712 90.007
11.1072 1.2260 13.617 15.237 89.371
11.1103 0.6130 6.811 7.727 88.140
11.1120 0.2510 2.789 3.388 82.323 > 77.30
QC 3.0
3.6
3.5999 3.0000 10.800 12.470 86.605
87.971 > 79.56 3.6078 2.2500 8.118 9.140 88.813
3.6151 1.5000 5.423 6.107 88.794
3.6225 0.7500 2.717 3.099 87.669
3.6271 0.3000 1.088 1.270 85.680 > 70.27
12
12.0240 2.2460 27.006 29.958 90.146
89.439 > 87.30 12.0270 1.6870 20.290 22.542 90.008
12.0300 1.1250 13.534 15.117 89.527
12.0330 0.5620 6.763 7.678 88.077
12.0340 0.2250 2.708 3.279 82.575 > 77.30
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
7. Efficiency ( Cont. ) VIN,AC
( V / Hz ) Mode
VBUS,SET
( V )
VBUS,PCB
( V )
IOUT
( A )
PBUS,PCB
( W )
PIN
( W )
η
( % )
ηAV,4-Points
( % )
Requirement
( % )
230 / 50
PD 3.0
5
5.0812 2.9940 15.213 17.147 88.722
87.670 > 81.84 5.0867 2.2440 11.415 12.908 88.430
5.0912 1.4960 7.616 8.671 87.838
5.0957 0.7480 3.812 4.448 85.692
5.0985 0.2960 1.509 1.888 79.934 > 72.48
9
9.1013 2.9940 27.249 30.097 90.538
89.662 > 87.30 9.1060 2.2440 20.434 22.664 90.160
9.1097 1.4960 13.628 15.196 89.682
9.1135 0.7480 6.817 7.723 88.267
9.1158 0.2960 2.698 3.324 81.176 > 77.30
PPS
3.3
3.3063 2.9510 9.757 11.281 86.490
85.460 > 78.93 3.3170 2.2460 7.450 8.626 86.367
3.3275 1.4980 4.985 5.800 85.941
3.3384 0.7480 2.497 3.007 83.044
3.3448 0.2960 0.990 1.258 78.701 > 69.66
11
11.1009 2.4110 26.764 29.561 90.539
89.435 > 87.30 11.1046 1.8410 20.444 22.676 90.155
11.1076 1.2260 13.618 15.229 89.421
11.1111 0.6130 6.811 7.773 87.625
11.1125 0.2510 2.789 3.495 79.807 > 77.30
QC 3.0
3.6
3.5999 3.0000 10.800 12.416 86.982
86.015 > 79.56 3.6078 2.2500 8.118 9.317 87.126
3.6153 1.5000 5.423 6.265 86.559
3.6225 0.7500 2.717 3.258 83.391
3.6270 0.3000 1.088 1.358 80.125 > 70.27
12
12.0240 2.2460 27.006 29.782 90.679
89.543 > 87.30 12.0270 1.6870 20.290 22.479 90.260
12.0300 1.1250 13.534 15.106 89.592
12.0330 0.5620 6.763 7.716 87.643
12.0350 0.2250 2.708 3.392 79.831 > 77.30
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
8. No Load Power Consumption
Input Voltage 115 VAC / 60 Hz 230 VAC / 50 Hz
Output Current 0 A ( Disconnect USB Type-C Cable )
Requirement < 30 mW < 75 mW ( CoC Tier 2 )
VIN,AC
( V / Hz )
PIN
( mW )
Requirement
( mW )
115 / 60 22 < 30
230 / 50 27 < 75
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition
Input Voltage 115 VAC / 60 Hz
Output Current No Load & Full Load
Measured Point of Output
Voltage End of PCB
Requirement
PD 3.0 Mode ∆ V < 0.5 V: < 25 mS
∆ V ≥ 0.5 V: < 275 mS
PPS Mode 20 mV / Step
QC 3.0 Mode 200 mV / Step
QC 2.0 Mode < 200 mS
Mode VBUS,SET
( V )
Transition Time
( mS ) Requirement
( mS ) 0 A 2.25 A ( for 12 V ) or 3 A
PD 3.0 5 → 9 10 10
< 275 9 → 5 40 40
QC 2.0
5 → 9 12 62
< 200
9 → 5 40 40
9 → 12 10 60
12 → 9 30 30
5 → 12 17 140
12 → 5 70 70
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
5 V → 9 V / 0 A 5 V → 9 V / 3 A
9 V → 5 V / 0 A 9 V → 5 V / 3 A
PD 3.0 Mode:
9. Output Voltage Transition ( Cont. )
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition ( Cont. )
3.3 V → 11 V / 0 A 3.3 V → 11 V / 2.4110 A
11 V → 3.3 V / 0 A 11 V → 3.3 V / 2.4110 A
PPS Mode ( 20 mV / Step ):
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
2.8A
1.4A
9. Output Voltage Transition ( Cont. )
PPS Mode ( SPT. 6 PPS Voltage Step Test ):
Workshop 107 TID025 VST: PASS
A. Purpose:
1. The PPS Step Test verifies that when a source port makes a contract using an APDO its output follows
the monotonicity and tolerance requirements from USB PD spec section 7.1.4.3.
2. This test is required for all USB PD ports that advertise APDO capabilities.
3. This is a single port test at this time.
4. This is a USB PD 3.0 test only.
C. Step Size Conditions:
1. 20mV
2. 100mV
3. 500mV
D. Operating Current Conditions:
1. 1 A
2. APDO Maximum Current / 2 + 500 mA
3. APDO Maximum Current
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition ( Cont. )
3.6 V → 12 V / 0 A 3.6 V → 12 V / 2.25 A
12 V → 3.6 V / 0 A 12 V → 3.6 V / 2.25 A
QC 3.0 Mode ( 200 mV / Step ):
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition ( Cont. )
5 V → 9 V / 0 A 5 V → 9 V / 3 A
9 V → 5 V / 0 A 9 V → 5 V / 3 A
QC 2.0 Mode:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition ( Cont. )
9 V → 12 V / 0 A 9 V → 12 V / 2.25 A
12 V → 9 V / 0 A 12 V → 9 V / 2.25 A
QC 2.0 Mode:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
9. Output Voltage Transition ( Cont. )
5 V → 12 V / 0 A 5 V → 12 V / 2.25 A
12 V → 5 V / 0 A 12 V → 5 V / 2.25 A
QC 2.0 Mode:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
10. Line / Load / Cross Regulation
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load & Full Load
Measured Point of Output
Voltage End of PCB
Requirement < ± 5 % of VBUS,SET
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
VBUS,PCB
( V ) Requirement
( V ) 0 A 3 A
PD 3.0
5
90 / 47 5.0983 5.0782
4.75 ~ 5.25 115 / 60 5.0983 5.0782
230 / 50 5.0986 5.0783
264 / 63 5.0985 5.0786
9
90 / 47 9.1173 9.1004
8.55 ~ 9.45 115 / 60 9.1172 9.0993
230 / 50 9.1172 9.0997
264 / 63 9.1177 9.0992
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
11. Constant Current
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Measured Point of Output
Voltage End of PCB
Requirement PPS Mode < ± 150 mA of IOUT,TYP
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
IOUT,CC
( A )
Requirement
( A )
PPS
3.3
90 / 47 2.962
2.85 ~ 3.15 115 / 60 2.962
230 / 50 2.962
264 / 63 2.962
5
90 / 47 2.970
2.85 ~ 3.15 115 / 60 2.970
230 / 50 2.970
264 / 63 2.968
9
90 / 47 2.979
2.85 ~ 3.15 115 / 60 2.975
230 / 50 2.971
264 / 63 2.973
11
90 / 47 2.428
2.30 ~ 2.60 115 / 60 2.424
230 / 50 2.422
264 / 63 2.426
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PPS Mode:
11. Constant Current ( Cont. )
2 V / Div
0.5 A / Div
11 V
9 V
5 V
3.3 V
2 V / Div
0.5 A / Div
11 V
9 V
5 V
3.3 V
2 V / Div
0.5 A / Div
11 V
9 V
5 V
3.3 V
2 V / Div
0.5 A / Div
11 V
9 V
5 V
3.3 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Measured Point of Output
Voltage End of PCB
Requirement QC 3.0 Mode Defined by Different Output Voltage
11. Constant Current ( Cont. )
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
IOUT,CC
( A )
Requirement
( A )
QC 3.0
3.6
90 / 47 3.271
3.135 ~ 3.465 115 / 60 3.271
230 / 50 3.271
264 / 63 3.271
5
90 / 47 3.271
3.135 ~ 3.465 115 / 60 3.271
230 / 50 3.271
264 / 63 3.271
9
90 / 47 3.275
3.135 ~ 3.465 115 / 60 3.275
230 / 50 3.273
264 / 63 3.273
12
90 / 47 2.469
2.33 ~ 2.63 115 / 60 2.469
230 / 50 2.467
264 / 63 2.465
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
QC 3.0 Mode:
11. Constant Current ( Cont. )
2 V / Div
0.5 A / Div
12 V
9 V
5 V
3.6 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
3.6 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
3.6 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
3.6 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Measured Point of Output Voltage End of PCB
Requirement QC 2.0 Mode Defined by Different Output Voltage
11. Constant Current ( Cont. )
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
IOUT,CC
( A )
Requirement
( A )
QC 2.0
5
90 / 47 3.279
3.135 ~ 3.465 115 / 60 3.275
230 / 50 3.275
264 / 63 3.273
9
90 / 47 3.285
3.135 ~ 3.465 115 / 60 3.281
230 / 50 3.279
264 / 63 3.275
12
90 / 47 2.478
2.33 ~ 2.63 115 / 60 2.478
230 / 50 2.476
264 / 63 2.476
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
QC 2.0 Mode:
11. Constant Current ( Cont. )
2 V / Div
0.5 A / Div
12 V
9 V
5 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
2 V / Div
0.5 A / Div
12 V
9 V
5 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
12. Over Current Protection
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Requirement
Protection Mode Auto Recovery
OCP Trigger
Point < 130 % of Full Load
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
IOUT,OCP
( A )
Requirement
Protection
Mode
OCP Trigger
Point
( A )
PD 3.0
5
90 / 47 3.510 Auto Recovery
< 3.9 115 / 60 3.510 Auto Recovery
230 / 50 3.510 Auto Recovery
264 / 63 3.510 Auto Recovery
9
90 / 47 3.495 Auto Recovery
< 3.9 115 / 60 3.495 Auto Recovery
230 / 50 3.495 Auto Recovery
264 / 63 3.495 Auto Recovery
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load & Full Load ( 3.3 V: 2.951 A / 5 V & 9 V: 3 A / 12 V: 2.250 A )
Measured Point of Output Voltage End of PCB
Requirement Defined by Different Output Voltage
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
VBUS,OVP
( V ) Requirement
( V ) No Load Full Load
PPS 3.3
90 / 47 4.44 4.32
< 4.95 115 / 60 4.52 4.20
230 / 50 4.56 4.28
264 / 63 4.56 4.28
PD 3.0 5
90 / 47 6.96 6.56
< 7.50 115 / 60 6.96 6.48
230 / 50 7.12 6.56
264 / 63 7.20 6.56
PD 3.0 9
90 / 47 11.8 11.0
<13.50 115 / 60 11.8 11.1
230 / 50 11.8 11.1
264 / 63 11.8 11.4
QC 3.0 12
90 / 47 15.1 14.6
< 16.00 115 / 60 15.2 14.8
230 / 50 15.4 14.9
264 / 63 15.4 14.8
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PPS Mode: 3.3 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PPS Mode: 3.3 V / 2.951 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 3 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V / 3 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
QC 3.0 Mode: 12 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
13. Over Voltage Protection ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
QC 3.0 Mode: 12 V / 2.25 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
14. Ripple & Noise Voltage
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load & Full Load
Measured Point of Output Voltage End of PCB
Bandwidth 20 MHz ( with 10 µF E-cap & 0.1 µF MLCC )
Requirement < 80 m V
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
VBUS,PK-PK
( mV ) Requirement
( mV ) 0 A 3 A
PD 3.0
5
90 / 47 48.0 46.4
< 80 115 / 60 52.0 44.8
230 / 50 54.4 37.6
264 / 63 52.0 52.8
9
90 / 47 40.0 68.8
< 80 115 / 60 40.8 56.8
230 / 50 43.2 72.8
264 / 63 39.2 67.2
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 3 A
14. Ripple & Noise Voltage ( Cont. )
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
14. Ripple & Noise Voltage ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V / 3 A
14. Ripple & Noise Voltage ( Cont. )
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V / 0 A
14. Ripple & Noise Voltage ( Cont. )
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
15. Dynamic Load
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current 0 ↔ 100 % of Full Load ( 0 A ↔ 3 A )
Frequency of Load 100 Hz ( 5 mS High / 5 mS Low )
Slew Rate of Load 2.5 A / µS
Measured Point of Output Voltage End of PCB
Requirement < ± 10 % of VBUS,SET
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
VBUS,PCB
( V ) Requirement
( V ) Min. Max.
PD 3.0
5
90 / 47 4.60 5.26
4.5 ~ 5.5 115 / 60 4.62 5.26
230 / 50 4.66 5.23
264 / 63 4.66 5.22
9
90 / 47 8.55 9.32
8.1 ~ 9.9 115 / 60 8.58 9.32
230 / 50 8.66 9.28
264 / 63 8.66 9.27
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
15. Dynamic Load ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
15. Dynamic Load ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
16. Turn-on Delay Time
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load & Full Load
Measured Point of Output
Voltage End of PCB
Requirement < 1 S
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
TON
( S ) Requirement
( S ) 0 A 3 A
PD 3.0 5
90 / 47 0.2982 0.2982
< 1 115 / 60 0.2782 0.2782
230 / 50 0.2612 0.2612
264 / 63 0.2552 0.2552
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
16. Turn-on Delay Time ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 3 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
16. Turn-on Delay Time ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
17. Hold-up Time
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current Full Load
Measured Point of Output
Voltage End of PCB
Angle of AC Off 0。
Requirement > 10 mS @ Typical AC Input
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
THOLD-UP
( mS )
Requirement
( mS )
PD 3.0 9
90 / 47 5.608
115 / 60 13.250 > 10
230 / 50 66.840 > 10
264 / 63 73.440
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
17. Hold-up Time ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 9 V / 3 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
18. Rise Time & Overshoot
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load
Measured Point of Output
Voltage End of PCB
Requirement Rise Time < 5 mS
Overshoot < 10 %
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
TRISE
( mS )
Requirement
( mS )
PD 3.0 5
90 / 47 0.1145
< 5 115 / 60 0.1155
230 / 50 0.1147
264 / 63 0.1154
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
Overshoot
( % )
Requirement
( % )
PD 3.0 5
90 / 47 2.308
< 10 115 / 60 1.538
230 / 50 2.308
264 / 63 1.538
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
18. Rise Time & Overshoot ( Cont. )
90 VAC / 47 Hz 115 VAC / 60 Hz
230 VAC / 50 Hz 264 VAC / 63 Hz
PD 3.0 Mode: 5 V / 0 A
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
19. AC Brown-in
Output Current No Load & Full Load
Measured Point of Output
Voltage End of PCB
Requirement < 85 VAC
Mode VBUS,SET
( V )
VBROWN-IN
( V ) Requirement
( VAC ) 0 A 3 A
PD 3.0 5 79.1 78.8 < 85
0 A 3 A
PD 3.0 Mode: 5 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
20. AC Brown-out
Output Current No Load & Full Load
Measured Point of Output
Voltage End of PCB
Requirement < 85 VAC
Mode VBUS,SET
( V )
VBROWN-OUT
( V ) Requirement
( VAC ) 0 A 3 A
PD 3.0 5 73.7 74.0 < 85
0 A 3 A
PD 3.0 Mode: 5 V
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
21. Supply Voltage of IC
Input Voltage 90 VAC / 47 Hz 115 VAC / 60 Hz 230 VAC / 50 Hz 264 VAC / 63 Hz
Output Current No Load & Full Load ( 3.3 V: 2.951 A / 12 V: 2.250 A )
Requirement > VCC_OFF & < VCC_OVP
Mode VBUS,SET
( V )
VIN,AC
( V / Hz )
VCC,U1
( V ) Requirement
( V ) No Load Full Load
Min. Max. Min. Max.
PPS 3.3
90 / 47 13.0 14.6 16.6 17.6
> 9.7 115 / 60 13.0 14.6 16.6 17.8
230 / 50 13.0 14.6 17.2 18.2
264 / 63 13.0 14.6 17.2 18.2
QC 3.0 12
90 / 47 44.8 48.4 53.2 55.6
< 68 115 / 60 44.8 48.4 52.0 54.8
230 / 50 44.8 48.4 52.8 55.2
264 / 63 44.8 48.4 52.8 55.2
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
22. Stress on Switching Parts
Input Voltage 264 VAC / 63 Hz
Output Current No Load & Full Load
Requirement Defined by Different Parts
Location Part No. Mode Condition VBUS,SET
( V )
IOUT
( A )
VDS
( V )
Requirement
( V )
Q1 SMK1065F QC 3.0 Normal 12 2.25 548 < 612
( 680 * 0.9 ) PD 3.0 Turn-on 5 0 456
Q2 AP9474GM-
HF
QC 3.0 Normal 12 2.25 54.4 < 57
( 60 * 0.95 ) PD 3.0 Turn-on 5 0 46.4
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
22. Stress on Switching Parts ( Cont. )
Q1_12 V / 2.25 A_Normal Q1_5 V / 0A_Turn-on
Q2_12 V / 2.25 A_Normal Q2_5 V / 0A_Turn-on
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
23. Flux Density of Transformer
Input Voltage 90 VAC / 47 Hz 264 VAC / 63 Hz
Output Current Full Load & Maximum Power
Requirement 90 % of Rating
Mode VBUS,SET
( V )
IOUT
( A )
VIN,AC
( V / Hz )
IPRI,MAX
( A )
BMAX
( G )
Requirement
( G )
PD 3.0 9
3 90 / 47 1.140 2,969
< 3,780
( 4,200 * 0.90 )
264 / 63 0.992 2,583
3.465 90 / 47 1.340 3,490
264 / 63 1.060 2,760
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
23. Flux Density of Transformer ( Cont. )
9 V / 3 A _90 VAC / 47 Hz 9 V / 3 A_264 VAC / 63 Hz
9 V / 3.465 A_90 VAC / 47 Hz 9 V / 3.465 A_264 VAC / 63 Hz
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI
PD 3.0 Mode: 9 V / 3 A
120 VAC / 60 Hz / Line 120 VAC / 60 Hz / Neutral
Conduction:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 9 V / 3 A
230 VAC / 50 Hz / Line 230 VAC / 50 Hz / Neutral
Conduction:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 5 V / 3 A
120 VAC / 60 Hz / Line 120 VAC / 60 Hz / Neutral
Conduction:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 5 V / 3 A
230 VAC / 50 Hz / Line 230 VAC / 50 Hz / Neutral
Conduction:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 9 V / 3 A
120 VAC / 60 Hz / Vertical 120 VAC / 60 Hz / Horizontal
Radiation:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 9 V / 3 A
230 VAC / 50 Hz / Vertical 230 VAC / 50 Hz / Horizontal
Radiation:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 5 V / 3 A
120 VAC / 60 Hz / Vertical 120 VAC / 60 Hz / Horizontal
Radiation:
Green your power Green the World The Best Company for AC-DC Mid & High Power Application Total Solution
24. EMI ( Cont. )
PD 3.0 Mode: 5 V / 3 A
230 VAC / 50 Hz / Vertical 230 VAC / 50 Hz / Horizontal
Radiation:
top related