A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

4936.7194.36[ ]

1174.6[ ] OPENING W/DOORS

REMOVED

1800 70.9[ ] 57122.5[ ]

A

2181

85.9

[]

142 5.6

[]

OPENING W/DOORS

REMOVED

1283

50.5

[]

B

1465 57.7[ ]

REF86033.8[ ]

369 14.5

[]

3197

125.9

[]

OPENING W/DOORS REMOVED

899 35.4[ ]

OUTLET SILENCER153 6.0[ ]

260 10.2

[]

858 33.8

[]

1424 56.0[ ]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 1 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (A-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET INFO

UPDATED [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

NOTES: FOR PROPER ASSEMBLY METHOD OF HARDWARE,USE G-585 AS A GUIDELINE.

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

12-48 HR SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

TANK INFORMATION

LITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)

1530 [404] 12 HOURS 350-400KW 406.4 [16.0] 4938.2 [194.4] 1110 [2446]

1771 [468] 12 HOURS 500KW 457.2 [18.0] 4938.2 [194.4] 1158 [2554]

2930 [774] 24 HOURS 350-400KW 762.0 [30.0] 4938.2 [194.4] 1401 [3089]

3384 [894] 24 HOURS 500KW 838.2 [33.0] 4938.2 [194.4] 1484 [3271]

4394 [1161] 36 HOURS 350-400KW

914.4 [36.0]

5637.2 [221.9] 1789 [3945]

5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 1982 [4370]

5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 2228 [4911]

6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 2524 [5565]

1530 [404] 12 HOURS STATE 350-400KW 381.0 [15.0] 5891.2 [231.9] 1281 [2825]

1771 [468] 12 HOURS STATE 500KW 431.8 [17.0] 5891.2 [231.9] 1326 [2923]

2930 [774] 24 HOURS STATE 350-400KW 660.4 [26.0] 5891.2 [231.9] 1547 [3411]

3384 [894] 24 HOURS STATE 500KW 736.6 [29.0] 5891.2 [231.9] 1630 [3594]

4394 [1161] 36 HOURS STATE 350-400KW

914.4 [36.0]

6069.0 [238.9] 1874 [4072]

5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 2094 [4616]

5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 2329 [5134]

6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 2656 [5855]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

OPENING W/DOORS

REMOVED

1283

50.5

[]

102540.4[ ] OPENING W/DOORS

REMOVED

1800 70.9[ ] 57122.5[ ] OPENING W/DOORS

REMOVED

899 35.4[ ]

A2344

92.3

[]

142 5.6

[]

B

4937 194.4[ ]

2591 102.0[ ]

1465 57.7[ ]

159 6.3

[]

3197

125.9

[]

2238 88.1[ ]

81632.1[ ]

1663

65.5

[]

1103

43.4

[]

263 10.4

[]

858 33.8

[]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 2 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

72 HR SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)10009 [2644] 72 HOURS STATE 350-500KW 914.4 [36.0] 7264.4 [286.0] 3582 [7898]

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.05 3 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

BATTERY CHARGER (LEFT SIDE)3 WAY SWITCH

W/GFI(LEFT SIDE)

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

DISTRIBUTION PANEL (LEFT SIDE)

DC LIGHT (QTY 2)

INCANDESCENT LIGHT (QTY 2) RAIN CAP

TIMER FORDC LIGHT

OPTIONAL DISCHARGE DAMPER (MOUNTED INSIDE DISCHARGE PLENUM)

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

4936 194.3[ ]

1425 56.1[ ]

1921

75.6

[]

142 5.6

[]117

4.6[ ] OPENING W/DOORS REMOVED

1800 70.9[ ] 57122.5[ ] OPENING W/DOORS

REMOVED

899 35.4[ ]

260 10.2

[]

OPENING W/DOORS

REMOVED

1283

50.5

[]

3185

125.4

[]

86033.8[ ]

368 14.5

[]

REF146257.6[ ]

1335 52.5[ ]

1546 60.9[ ]

2697 106.2[ ]

4860 191.3[ ]

1345.3[ ]

934 36.8[ ]

3635 143.1[ ]

858 33.8

[]

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 4 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-26-12

PKD 10-26-12

AJD 10-26-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-26-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

350-500KW REOZJBSTEEL & ALUMINUM ENCL.

SL1/WEATHER

1778.0 X 500.4[70.0 X 19.7]

FIXED AIR INTAKELOUVER (STANDARD)

(RIGHT & LEFT SIDE)

12X �n�25.4

350-500 REOZJB KG [LBS]

STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]

ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]

STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]

ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

1334.6

52.54

[]

45 1.8

[]

1425

56.1

[]

BOTTOM FLANGE TYP.25.4 1.00[ ]

R S T U V W

482 19.0

[]

342 13.5

[]

1817.1[ ]

72628.6[ ]

X Y Z ZA

B

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.08 5 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND

GENSET INFO UPDATED [CT83640] NMD

C 2-3-17 SEE SHEET 7 [CT170345] PAS

12 - 48 HOUR350-500kW STD TANK

SL1/WEATHER

1531 [404GAL.] 12 HOUR TANK SHOWN.

12

3

4

56

7 1

CONDUIT ENTRYAREA

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 FILL CAP, 2" LOCKABLE W/PIPE RISER

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 VENT, NORMAL

7 SWITCH, FUEL IN BASIN

TABLE INFORMATION

LITERS [GALLONS] MIN HOURS GENSETS B R S T U V W X Y Z ZA

1530 [404] 12 HOURS 350-400KW 4938.2 [194.4]

83.1[3.27]

1217.6[47.94]

937.9[36.93]

482.6[19.00]

668.6[26.32]

931.5[36.67]

523.9 [20.63]1771 [468] 12 HOURS 500KW 4938.2 [194.4]

2930 [774] 24 HOURS 350-400KW 4938.2 [194.4]

3384 [894] 24 HOURS 500KW 4938.2 [194.4]

4394 [1161] 36 HOURS 350-400KW 5637.2 [221.9] 574.6 [22.62] 648.3 [25.52]

5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 704.3 [27.73] 577.0 [22.72] 576.6 [22.70]

5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 684.3 [26.94] 591.3 [23.28] 588.9 [23.19] 704.6 [27.74]

6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 704.3 [27.73] 891.3 [35.09] 868.9 [34.21] 968.2 [38.12]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.NMD

P Q R S

1334.6

52.54

[]

T U V

45 1.8

[]

1425

56.1

[]

BOTTOM FLANGE TYP.25.4 1.00[ ]

482.0

18.98

[]

342.0

13.46

[]

180.87.12[ ]

726.028.58[ ]

W X Y Z

B

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 6 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 SEE SHEET 7 [CT59787] SVP

B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET

INFO UPDATED [CT83640]

C 2-3-17 SEE SHEET 7 [CT170345] PAS

12 - 48 HOUR350-500kW STATE TANK

SL1/WEATHER

1531 [404 GAL.] 12 HOUR TANK SHOWN.

GROUND CLEARANCE I-BEAM MOUNTING HOLE ONLY

2

3 5

711

64

8

9 10

11

CONDUIT ENTRY AREA

9

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 PLUG, PIPE (2" NPT)

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 GAUGE, FUEL LEVEL, DIRECT READ

7 VENT, NORMAL

8 SWITCH, FUEL IN BASIN TOP MTD, 2"

9 PLUG, PIPE (2"NPT)

10 PLUG, PIPE (1/2"NPTF)

11 FILL CAP, 2" LOCKABLE W/PIPE RISER

INFORMATION TABLE

LITERS [GALLONS] MIN HOURS GENSETS B P Q R S T U V W X Y Z

1530 [404] 12 HOURS STATE 350-400KW 5891.2 [231.9]

83.1[3.27]

1217.6[47.94]

937.9[36.93]

482.6[19.00]

668.6[26.32]

931.5[36.67]

664.2 [26.15] 812.7 [32.00]1771 [468] 12 HOURS STATE 500KW 5891.2 [231.9]

2930 [774] 24 HOURS STATE 350-400KW 5891.2 [231.9]

704.3 [27.73]

772.6 [30.42]

3385 [894] 24 HOURS STATE 500KW 5891.2 [231.9] 772.6 [30.42]

4395 [1161] 36 HOURS STATE 350-400KW 6069.0 [238.9] 950.4 [37.42]

5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 891.3 [35.09] 821.1 [32.33]

5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 891.3 [35.09] 868.9 [34.21] 790.4 [31.12]

6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 891.3 [35.09] 868.9 [34.21] 1084.3 [42.69] 747.5 [29.43]

A

12345678

B

C

D

12345678

A

B

C

D

TITLE

SCALE

DWG NO.

CAD NO. SHEET

DRAWN

CHECKED

APPROVED

MAX.

THIRD ANGLEPROJECTION

POWER SYSTEMS, KOHLER, WI 53044 U .S.A.

THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.

P Q R S T U V W X

38.1

1.50

[]

2514.6

99.00

[]

2590.8

102.00

[]

914.4

36.00

[]

GENSET MOUNTING

1076.5

42.38

[]

1065.1

41.93

[]

342.0

13.46

[]

1089.042.87[ ]

719.428.32[ ]

B

C

D

E

PRO-EMETRIC

DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK

0.40 7 of 7

ADV-8514 D

UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:

X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'

APPROVALS DATE

KNN

10-25-12

PKD 10-25-12

AJD 10-25-12

REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY

- 10-25-12 NEW DRAWING [CT28128] KNN

A 10-10-13 (D-7,D-6,D-5) DIM. C, D & E ADDED; (A-8) TANK

INFORMATION TABLE UPDATED [CT59787] SVP

B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD

C 2-3-17 VIEWS UPDATED FOR LIFTING PLATES [CT170345] PAS

72 HOUR350-500kW STATE TANK

SL1/WEATHER

STATE TANK

2

3 5

7

1

6

4

8

9

9

10

1

CONDUIT ENTRYAREA

ITEM DESCRIPTION

1 CAP, EMERGENCY VENT

2 PLUG, PIPE (2" NPT)

3 GAUGE, FUEL LEVEL, W/ SENDER

4 SUPPLY, FUEL (1/2" NPT)

5 RETURN, FUEL (1/2" NPT)

6 GAUGE, FUEL LEVEL, DIRECT READ

7 VENT, NORMAL

8 SWITCH, FUEL IN BASIN TOP MTD, 2"

9 PLUG, PIPE (2" NPT)

10 FILL CAP, 2" LOCKABLE W/PIPE RISER

TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS B C D E P Q R S T U V W X

10009 [2644] 72 HOURS STATE350-400KW 7264.4

[286.0]1595.1[62.8]

5542.3[218.2]

6624.3[260.8]

461.6[18.2]

520.9[20.5]

1224.5[48.2]

804.0[31.7]

778.5[30.7]

638.1[25.1]

570.2[22.5]

1067.2[42.0]

1097.9[43.2]500KW