8 7 6 5 4 3 2 1 - kohler co.resources.kohler.com/power/kohler/industrial/pdf/adv8514.pdf · metric...
Post on 28-Jul-2018
214 Views
Preview:
TRANSCRIPT
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
4936.7194.36[ ]
1174.6[ ] OPENING W/DOORS
REMOVED
1800 70.9[ ] 57122.5[ ]
A
2181
85.9
[]
142 5.6
[]
OPENING W/DOORS
REMOVED
1283
50.5
[]
B
1465 57.7[ ]
REF86033.8[ ]
369 14.5
[]
3197
125.9
[]
OPENING W/DOORS REMOVED
899 35.4[ ]
OUTLET SILENCER153 6.0[ ]
260 10.2
[]
858 33.8
[]
1424 56.0[ ]
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.05 1 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 (A-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET INFO
UPDATED [CT83640] NMD
C 2-3-17 SEE SHEET 7 [CT170345] PAS
NOTES: FOR PROPER ASSEMBLY METHOD OF HARDWARE,USE G-585 AS A GUIDELINE.
350-500KW REOZJBSTEEL & ALUMINUM ENCL.
12-48 HR SL1/WEATHER
1778.0 X 500.4[70.0 X 19.7]
FIXED AIR INTAKELOUVER (STANDARD)
(RIGHT & LEFT SIDE)
350-500 REOZJB KG [LBS]
STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]
ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]
STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]
ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]
TANK INFORMATION
LITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)
1530 [404] 12 HOURS 350-400KW 406.4 [16.0] 4938.2 [194.4] 1110 [2446]
1771 [468] 12 HOURS 500KW 457.2 [18.0] 4938.2 [194.4] 1158 [2554]
2930 [774] 24 HOURS 350-400KW 762.0 [30.0] 4938.2 [194.4] 1401 [3089]
3384 [894] 24 HOURS 500KW 838.2 [33.0] 4938.2 [194.4] 1484 [3271]
4394 [1161] 36 HOURS 350-400KW
914.4 [36.0]
5637.2 [221.9] 1789 [3945]
5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 1982 [4370]
5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 2228 [4911]
6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 2524 [5565]
1530 [404] 12 HOURS STATE 350-400KW 381.0 [15.0] 5891.2 [231.9] 1281 [2825]
1771 [468] 12 HOURS STATE 500KW 431.8 [17.0] 5891.2 [231.9] 1326 [2923]
2930 [774] 24 HOURS STATE 350-400KW 660.4 [26.0] 5891.2 [231.9] 1547 [3411]
3384 [894] 24 HOURS STATE 500KW 736.6 [29.0] 5891.2 [231.9] 1630 [3594]
4394 [1161] 36 HOURS STATE 350-400KW
914.4 [36.0]
6069.0 [238.9] 1874 [4072]
5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 2094 [4616]
5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 2329 [5134]
6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 2656 [5855]
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
OPENING W/DOORS
REMOVED
1283
50.5
[]
102540.4[ ] OPENING W/DOORS
REMOVED
1800 70.9[ ] 57122.5[ ] OPENING W/DOORS
REMOVED
899 35.4[ ]
A2344
92.3
[]
142 5.6
[]
B
4937 194.4[ ]
2591 102.0[ ]
1465 57.7[ ]
159 6.3
[]
3197
125.9
[]
2238 88.1[ ]
81632.1[ ]
1663
65.5
[]
1103
43.4
[]
263 10.4
[]
858 33.8
[]
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.05 2 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD
C 2-3-17 SEE SHEET 7 [CT170345] PAS
350-500KW REOZJBSTEEL & ALUMINUM ENCL.
72 HR SL1/WEATHER
1778.0 X 500.4[70.0 X 19.7]
FIXED AIR INTAKELOUVER (STANDARD)
(RIGHT & LEFT SIDE)
TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS DIM A MM [INCH] DIM B MM [INCH] TANK WEIGHT KG [LBS] (NO FUEL)10009 [2644] 72 HOURS STATE 350-500KW 914.4 [36.0] 7264.4 [286.0] 3582 [7898]
350-500 REOZJB KG [LBS]
STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]
ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]
STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]
ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.05 3 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD
C 2-3-17 SEE SHEET 7 [CT170345] PAS
BATTERY CHARGER (LEFT SIDE)3 WAY SWITCH
W/GFI(LEFT SIDE)
1778.0 X 500.4[70.0 X 19.7]
FIXED AIR INTAKELOUVER (STANDARD)
(RIGHT & LEFT SIDE)
DISTRIBUTION PANEL (LEFT SIDE)
DC LIGHT (QTY 2)
INCANDESCENT LIGHT (QTY 2) RAIN CAP
TIMER FORDC LIGHT
OPTIONAL DISCHARGE DAMPER (MOUNTED INSIDE DISCHARGE PLENUM)
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
4936 194.3[ ]
1425 56.1[ ]
1921
75.6
[]
142 5.6
[]117
4.6[ ] OPENING W/DOORS REMOVED
1800 70.9[ ] 57122.5[ ] OPENING W/DOORS
REMOVED
899 35.4[ ]
260 10.2
[]
OPENING W/DOORS
REMOVED
1283
50.5
[]
3185
125.4
[]
86033.8[ ]
368 14.5
[]
REF146257.6[ ]
1335 52.5[ ]
1546 60.9[ ]
2697 106.2[ ]
4860 191.3[ ]
1345.3[ ]
934 36.8[ ]
3635 143.1[ ]
858 33.8
[]
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.40 4 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-26-12
PKD 10-26-12
AJD 10-26-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-26-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD
C 2-3-17 SEE SHEET 7 [CT170345] PAS
350-500KW REOZJBSTEEL & ALUMINUM ENCL.
SL1/WEATHER
1778.0 X 500.4[70.0 X 19.7]
FIXED AIR INTAKELOUVER (STANDARD)
(RIGHT & LEFT SIDE)
12X �n�25.4
350-500 REOZJB KG [LBS]
STEEL WEATHER ENCLOSURE WEIGHT 916 [2020]
ALUM. WEATHER ENCLOSURE WEIGHT 535 [1180]
STEEL SOUND L1 ENCLOSURE WEIGHT 952 [2100]
ALUM. SOUND L1 ENCLOSURE WEIGHT 575 [1260]
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
1334.6
52.54
[]
45 1.8
[]
1425
56.1
[]
BOTTOM FLANGE TYP.25.4 1.00[ ]
R S T U V W
482 19.0
[]
342 13.5
[]
1817.1[ ]
72628.6[ ]
X Y Z ZA
B
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.08 5 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND
GENSET INFO UPDATED [CT83640] NMD
C 2-3-17 SEE SHEET 7 [CT170345] PAS
12 - 48 HOUR350-500kW STD TANK
SL1/WEATHER
1531 [404GAL.] 12 HOUR TANK SHOWN.
12
3
4
56
7 1
CONDUIT ENTRYAREA
ITEM DESCRIPTION
1 CAP, EMERGENCY VENT
2 FILL CAP, 2" LOCKABLE W/PIPE RISER
3 GAUGE, FUEL LEVEL, W/ SENDER
4 SUPPLY, FUEL (1/2" NPT)
5 RETURN, FUEL (1/2" NPT)
6 VENT, NORMAL
7 SWITCH, FUEL IN BASIN
TABLE INFORMATION
LITERS [GALLONS] MIN HOURS GENSETS B R S T U V W X Y Z ZA
1530 [404] 12 HOURS 350-400KW 4938.2 [194.4]
83.1[3.27]
1217.6[47.94]
937.9[36.93]
482.6[19.00]
668.6[26.32]
931.5[36.67]
523.9 [20.63]1771 [468] 12 HOURS 500KW 4938.2 [194.4]
2930 [774] 24 HOURS 350-400KW 4938.2 [194.4]
3384 [894] 24 HOURS 500KW 4938.2 [194.4]
4394 [1161] 36 HOURS 350-400KW 5637.2 [221.9] 574.6 [22.62] 648.3 [25.52]
5046 [1333] 48/36 HOURS 350/500KW 6272.2 [246.9] 704.3 [27.73] 577.0 [22.72] 576.6 [22.70]
5765 [1523] 48 HOURS 400KW 6983.4 [274.9] 684.3 [26.94] 591.3 [23.28] 588.9 [23.19] 704.6 [27.74]
6674 [1763] 48 HOURS 500KW 7847.0 [308.9] 704.3 [27.73] 891.3 [35.09] 868.9 [34.21] 968.2 [38.12]
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.NMD
P Q R S
1334.6
52.54
[]
T U V
45 1.8
[]
1425
56.1
[]
BOTTOM FLANGE TYP.25.4 1.00[ ]
482.0
18.98
[]
342.0
13.46
[]
180.87.12[ ]
726.028.58[ ]
W X Y Z
B
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.40 6 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 SEE SHEET 7 [CT59787] SVP
B 06-09-14 (D-8) 1333 & 1523 GAL TANKS: HOURS AND GENSET
INFO UPDATED [CT83640]
C 2-3-17 SEE SHEET 7 [CT170345] PAS
12 - 48 HOUR350-500kW STATE TANK
SL1/WEATHER
1531 [404 GAL.] 12 HOUR TANK SHOWN.
GROUND CLEARANCE I-BEAM MOUNTING HOLE ONLY
2
3 5
711
64
8
9 10
11
CONDUIT ENTRY AREA
9
ITEM DESCRIPTION
1 CAP, EMERGENCY VENT
2 PLUG, PIPE (2" NPT)
3 GAUGE, FUEL LEVEL, W/ SENDER
4 SUPPLY, FUEL (1/2" NPT)
5 RETURN, FUEL (1/2" NPT)
6 GAUGE, FUEL LEVEL, DIRECT READ
7 VENT, NORMAL
8 SWITCH, FUEL IN BASIN TOP MTD, 2"
9 PLUG, PIPE (2"NPT)
10 PLUG, PIPE (1/2"NPTF)
11 FILL CAP, 2" LOCKABLE W/PIPE RISER
INFORMATION TABLE
LITERS [GALLONS] MIN HOURS GENSETS B P Q R S T U V W X Y Z
1530 [404] 12 HOURS STATE 350-400KW 5891.2 [231.9]
83.1[3.27]
1217.6[47.94]
937.9[36.93]
482.6[19.00]
668.6[26.32]
931.5[36.67]
664.2 [26.15] 812.7 [32.00]1771 [468] 12 HOURS STATE 500KW 5891.2 [231.9]
2930 [774] 24 HOURS STATE 350-400KW 5891.2 [231.9]
704.3 [27.73]
772.6 [30.42]
3385 [894] 24 HOURS STATE 500KW 5891.2 [231.9] 772.6 [30.42]
4395 [1161] 36 HOURS STATE 350-400KW 6069.0 [238.9] 950.4 [37.42]
5046 [1333] 48/36 HOURS STATE 350/500KW 6831.0 [268.9] 891.3 [35.09] 821.1 [32.33]
5765 [1523] 48 HOURS STATE 400KW 7669.2 [301.9] 891.3 [35.09] 868.9 [34.21] 790.4 [31.12]
6674 [1763] 48 HOURS STATE 500KW 8710.6 [342.9] 891.3 [35.09] 868.9 [34.21] 1084.3 [42.69] 747.5 [29.43]
A
12345678
B
C
D
12345678
A
B
C
D
TITLE
SCALE
DWG NO.
CAD NO. SHEET
DRAWN
CHECKED
APPROVED
MAX.
THIRD ANGLEPROJECTION
POWER SYSTEMS, KOHLER, WI 53044 U .S.A.
THIS DRAWING IN DESIGN AND DETAIL IS KOHLER CO.PROPERTY AND MUST NOT BE USED EXCEPT INCONNECTION WITH KOHLER CO. WORK. ALL RIGHTS OFDESIGN OR INVENTION ARE RESERVED.
P Q R S T U V W X
38.1
1.50
[]
2514.6
99.00
[]
2590.8
102.00
[]
914.4
36.00
[]
GENSET MOUNTING
1076.5
42.38
[]
1065.1
41.93
[]
342.0
13.46
[]
1089.042.87[ ]
719.428.32[ ]
B
C
D
E
PRO-EMETRIC
DIMENSION PRINT, 350-500REOZJB SND LVL 1 & TANK
0.40 7 of 7
ADV-8514 D
UNLESS OTHERWISE SPECIFIED -1) DIMENSIONS ARE IN MILLIMETERS2) TOLERANCES ARE:
X.XX �#� 0.25X.X �#� 1.0X �#� 1.5 SURFACE FINISHANGLES �#� 0�$� 30'
APPROVALS DATE
KNN
10-25-12
PKD 10-25-12
AJD 10-25-12
REV DATE ON COMPOSITE DWGS, SEE PART NO. FOR REVISION LEVEL BY
- 10-25-12 NEW DRAWING [CT28128] KNN
A 10-10-13 (D-7,D-6,D-5) DIM. C, D & E ADDED; (A-8) TANK
INFORMATION TABLE UPDATED [CT59787] SVP
B 06-09-14 SEE SHEET 1,5 & 6 [CT83640] NMD
C 2-3-17 VIEWS UPDATED FOR LIFTING PLATES [CT170345] PAS
72 HOUR350-500kW STATE TANK
SL1/WEATHER
STATE TANK
2
3 5
7
1
6
4
8
9
9
10
1
CONDUIT ENTRYAREA
ITEM DESCRIPTION
1 CAP, EMERGENCY VENT
2 PLUG, PIPE (2" NPT)
3 GAUGE, FUEL LEVEL, W/ SENDER
4 SUPPLY, FUEL (1/2" NPT)
5 RETURN, FUEL (1/2" NPT)
6 GAUGE, FUEL LEVEL, DIRECT READ
7 VENT, NORMAL
8 SWITCH, FUEL IN BASIN TOP MTD, 2"
9 PLUG, PIPE (2" NPT)
10 FILL CAP, 2" LOCKABLE W/PIPE RISER
TANK INFORMATIONLITERS [GALLONS] MIN HOURS GENSETS B C D E P Q R S T U V W X
10009 [2644] 72 HOURS STATE350-400KW 7264.4
[286.0]1595.1[62.8]
5542.3[218.2]
6624.3[260.8]
461.6[18.2]
520.9[20.5]
1224.5[48.2]
804.0[31.7]
778.5[30.7]
638.1[25.1]
570.2[22.5]
1067.2[42.0]
1097.9[43.2]500KW
top related