a t f analytical task force for chemical distress bra bersuch
Post on 05-Apr-2015
105 Views
Preview:
TRANSCRIPT
A T F
Analytical Task Force for Chemical Distress
BRA Bersuch
2
3
» Task
» location
» devices
» Alarm
4
Three Step System:
Federal Task forces, Disaster, special situations like terrorism
State special units either financed from the state or from the federal government, more complex incidents
Municipal local fire brigade, normal incident situations
5
Task:
• Detection and Identification• Monitoring. • Evaluation.• Risk assessment.• Consulting service.• Consulting service on the spot.• Consulting service for medical personnel (eg. MEMPLEX).
6
ATF in Germany
– BF Hamburg
– BF Mannheim
– LKA Berlin (Police)
– IdF Sachsen – Anhalt
– Three more locations in planning
7
(HGDA2) GDA2 Hazardous Goods Detection Array2
GC-MS Gaschromatograph-Massspectrometer
FTIR Fourier-transformed-Infraredspectrometer
1. SIGIS 2 2. HazMat ID
8
Gefahrstoff Detector Array 2(GDA2)
Detection and Monitoring of Gases and CWA
ETW-List
(Einsatztoleranzwert)
CWA-List
(Chemical Warfare Agents)
9
Gaschromatograph-Massenspektrometer (GC-MS)
Gas chromatograph with Mass Spectrometer coupling
Analyse of volatile Substances in:
–Air–Water –Soil
10
Aufbau des GC-MS
GCMSGCMS: Bauteile
Electrical Power
Computer
MS Mass Spectrometer
Electronic-Module
Gas- Supply- module
GC Gas-ChromatographParts
TUHH
11
Analytische Bandbreite des GC-MS
» Organic Chemicals» Industrial Chemicals» ETW-Substances» Pesticides» Smoke analytic» Forge water analytic.» Drug detection» Explosives» CWA
More than 180.000 Substances and mixtures from the area of the organic Chemistry
(VOC).
12
Fourier-Infrarotspektrometrie (FTIR)
SIGIS II (Scanning Infrared Gas-Measurement Imaging System II)
Passive Infrared Spectrometer
• Long distance detection of Hazardous goods (clouds) less than 5 km up to 17 Km (Etna), weather dependent
• Detection of all infrared active substances.
• Detection of abnormal air phenomena
13
Fourier-Infrarotspektrometrie FTIR
Teleskop
GPS
Scanner-spiegel
Interferometer
Drehbarer Kopf
TUHH
14
Fourier-Infrarotspektrometrie FTIR
Identification of Ammonia
TUHH
15
HazMat ID
Active Infrared Spectrometer
HazMat ID (Hazardous Materials Identification)
Identification of:
» Solid substances» Liquid substances» Limited usable for Biological substances
16
HazMat ID
Display
17
Alarming and Request ATF
• Decision on the spot
• GEL > GMLZ > ATF
• Evaluation by the ATF
• If necessary request for assistance !
18
1. Advice by telephone.
2. Consulter to the Spot.
3. Whole ATF to the spot.
3.1 Autarchy.
3.2 Transport to the spot.
3.3 leading structure on the spot.
19
Einsätze der ATF in 2006-2007
1. Rhadereistedt
- 4 Tote in Biogasanlage nach Austritt von H2S
- Humanfreimessungen für das
Gerichtsmedizinische Institut
2. WM 2006 in Deutschland
- Monitoring der Stadien und der Versammlungs- stätten an Großveranstaltungsorten
- ABC-Abwehrkonzept
3. Strahlsund
- Monitoring beim Besuch des Amerikanischen Präsidenten
20
Einsätze der ATF in 2006-2007
4. Teilnahme der ATF an der Europäischen Übung EUDAN EX
- Übung eines Bahnunglücks im Tunnel mit Austritt von gefährlichen Chemikalien
- Analyse an einer schmutzigen Bombe mit
realen Kampfstoffen
5. Bahnunglück in Tornesch
- Monitoring des Areals
- Analysen mit Feldversuchen vor Ort
- Beratung des GEL und des Landkreises
6. ABC-Schule der Bundeswehr in Sonthofen
- Identifikation und Vermessung von CWA
21
Einsätze der ATF in 2006-2007
7. ASEM-Gipfel in Hamburg
- Monitoring der Unterkunfts- und Tagungsstätten der Staatsgäste
8. G8-Gipfel in Heiligendamm
- Polizeiliche- und nichtpolizeiliche C-Abwehr
- Monitoring der Demonstrations- und
Eventstätten
- Feldanalytik im AB-SM (Kontrollpunkte)
- Probenvermessung mit GDA GCMS etc.
- Beratung des Kavalla-, des NipoG-Stabes und der Kräfte vor Ort
22
Vielen Dank für Ihre Aufmerksamkeit!
top related