a2 floor... · door/frame/hardware schedule room door frame no. name type thickness height width...
Post on 26-Mar-2020
4 Views
Preview:
TRANSCRIPT
TRAVEL DISTANCE 29'-3" 8.9M
TRAV
EL D
ISTAN
CE 1
30'-5
" 39.
75M
227
228236238
235237
239
239a
2S12C1
2C2
243
240
242
245
249
246
248
251
255
254
256
257258
260
261
2S2
2C3
DOOR/FRAME/HARDWARE SCHEDULEROOM DOOR FRAME
NO. NAME TYPE
THIC
KNES
S
HEIG
HT
WIDT
H
MATE
RIAL
FINIS
H
INSU
LATE
D
FIRE
RATIN
G
GLAZ
ING
MATE
RIAL
FINIS
H
THER
MALL
Y BRO
KEN
FIRE
RATIN
G
WEAT
HERS
TRIPP
ING
DOOR
CLO
SER
ALUM
INUM
THRE
SH.
PASS
AGE/P
USH
PULL
PRIV
ACY
LOCK
ING
EXIT
HARD
WARE
KICK
PLAT
E
HARDWARE NOTES
ROOM FINISH SCHEDULE
NO. NAME VCT
CARP
ET
RUBB
ER B
ASE
PAIN
T
PAIN
T
PAIN
T
PAIN
T
N E S W
CEILI
NG H
EIGHT
PAIN
TED
CONC
RETE
GYPS
UM
ROOM FLOOR WALLS CEILING NOTES
DOOR GROUP 1
227 STAFF228 RECEPTION231 WASHROOM
239a MECHANICAL
GROUP A
GROUP B
GROUP C
227 STAFF
228 RECEPTION
2S1 STAIR LANDING
239a MECHANICAL
2C1 CORRIDOR
243 MECHANICAL243b MOP CLOSET
231 WASHROOM
2C2 CORRIDOR
2C3 CORRIDOR
243 MECHANICAL
1 3/4"1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
78"78"
78"
84"
78"
84"
84"
78"
78"
78"
WOODWOOD
WOOD
WOOD
WOOD
H.M.
WOOD
WOOD
WOOD
32"32"
32"
36"
32"
36"
32"
32"
32"
32"
PTPT
PT
PT
PT
PT
PT
PT
PT
PT
WOODWOOD
WOOD
WOOD
WOOD
H.M.
H.M.
WOOD
WOOD
WOOD
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
1 2 3
4
12
3
4
5
6
1
3
3
3
EXISTING DOOR & HARDWARE
DOOR TYPE ELEVATIONS
EXISTING DOUBLE DOOR & HARDWARE
DOOR TYPE GROUPSGROUP 1 - DOORS :235, 236, 237, 238, 239, 240, 242, 244, 245,246, 247, 248, 249, 250, 251, 253, 257, 259,260, 261
GROUP 2 - DOORS :254, 255GROUP 3 - DOORS :256, 258GROUP 4 - DOORS :2C1, 2C2, 2C3
DOOR GROUP 2
DOOR GROUP 3
DOOR GROUP 4
254b CLOSET
ROOM TYPE GROUPSGROUP A - ACADEMIC ROOMS :242-44, 245-47, 248-50, 251-53, 257-59GROUP B - SEMINAR ROOMS :240, 243, 246, 249, 261GROUP C - OFFICE ROOMS :235, 236, 237, 238, 239
WASHROOM
WASHROOM
SHOWERS
254
255
256
256 PRAYER
260 OFFICE
N.I.C.
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2
4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2
PTPT
PT
PT
PT
PT
PT
PT
PT
PT
PT PT
EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE - RELOCATED
1 3/4" 78" 24"
9
WOOD
WOOD
WOOD
2S1
2S21 3/4" 84" WOOD60" PT WOOD
EXISTING DOOR & HARDWARE
PT
1 3/4" 84" WOOD36" PT WOOD PT
STAIRWELL
STAIRWELL
234 WASHROOM 1 3/4" 78" WOOD24" PT WOOD PT
EXISTING DOOR & HARDWARE w/ NEW 22"x30" GLAZING INSERTEXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
3' FULL HEIGHT SIDE LITE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE - RELOCATED
7
8
9
6'-6"
2'-8"
2'-6"
1'-10" 6'-6"
2'-8"
6'-6"
2'-8"
3'-0"
7'-0"
5
5'-0"
7'-0"
6
3'-0"
7'-0"
7
7'-0"
3'-0"
8
7'-0"
2'-8"
3'-0"
9
6'-6"
2'-4"
0'-4"
3'-0"
2'-0" 0'-
8"0'-
8"0'-
8"
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOORO.B.C ANALYSIS, LIFE SAFETY $ SCHEDULES
PR14-034
RLN
DCB
MAY 08 / 2015A2.1
1/16" = 1'-0"2 LIFE-SAFETY PLAN
TRAVEL DISTANCE 35'-1" 10.7M
D150101
0 ISSUED FOR TENDER MAY 08 2015
TRAVEL DISTANCE 29'-3" 8.9M
TRAV
EL D
ISTAN
CE 1
30'-5
" 39.
75M
227
228236238
235237
239
239a
2S12C1
2C2
243
240
242
245
249
246
248
251
255
254
256
257258
260
261
2S2
2C3
DOOR/FRAME/HARDWARE SCHEDULEROOM DOOR FRAME
NO. NAME TYPE
THIC
KNES
S
HEIG
HT
WIDT
H
MATE
RIAL
FINIS
H
INSU
LATE
D
FIRE
RATIN
G
GLAZ
ING
MATE
RIAL
FINIS
H
THER
MALL
Y BRO
KEN
FIRE
RATIN
G
WEAT
HERS
TRIPP
ING
DOOR
CLO
SER
ALUM
INUM
THRE
SH.
PASS
AGE/P
USH
PULL
PRIV
ACY
LOCK
ING
EXIT
HARD
WARE
KICK
PLAT
E
HARDWARE NOTES
ROOM FINISH SCHEDULE
NO. NAME VCT
CARP
ET
RUBB
ER B
ASE
PAIN
T
PAIN
T
PAIN
T
PAIN
T
N E S W
CEILI
NG H
EIGHT
PAIN
TED
CONC
RETE
GYPS
UM
ROOM FLOOR WALLS CEILING NOTES
DOOR GROUP 1
227 STAFF228 RECEPTION231 WASHROOM
239a MECHANICAL
GROUP A
GROUP B
GROUP C
227 STAFF
228 RECEPTION
2S1 STAIR LANDING
239a MECHANICAL
2C1 CORRIDOR
243 MECHANICAL243b MOP CLOSET
231 WASHROOM
2C2 CORRIDOR
2C3 CORRIDOR
243 MECHANICAL
1 3/4"1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
1 3/4"
78"78"
78"
84"
78"
84"
84"
78"
78"
78"
WOODWOOD
WOOD
WOOD
WOOD
H.M.
WOOD
WOOD
WOOD
32"32"
32"
36"
32"
36"
32"
32"
32"
32"
PTPT
PT
PT
PT
PT
PT
PT
PT
PT
WOODWOOD
WOOD
WOOD
WOOD
H.M.
H.M.
WOOD
WOOD
WOOD
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
1 2 3
4
12
3
4
5
6
1
3
3
3
EXISTING DOOR & HARDWARE
DOOR TYPE ELEVATIONS
EXISTING DOUBLE DOOR & HARDWARE
DOOR TYPE GROUPSGROUP 1 - DOORS :235, 236, 237, 238, 239, 240, 242, 244, 245,246, 247, 248, 249, 250, 251, 253, 257, 259,260, 261
GROUP 2 - DOORS :254, 255GROUP 3 - DOORS :256, 258GROUP 4 - DOORS :2C1, 2C2, 2C3
DOOR GROUP 2
DOOR GROUP 3
DOOR GROUP 4
254b CLOSET
ROOM TYPE GROUPSGROUP A - ACADEMIC ROOMS :242-44, 245-47, 248-50, 251-53, 257-59GROUP B - SEMINAR ROOMS :240, 243, 246, 249, 261GROUP C - OFFICE ROOMS :235, 236, 237, 238, 239
WASHROOM
WASHROOM
SHOWERS
254
255
256
256 PRAYER
260 OFFICE
N.I.C.
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
8'-0"
4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2
4"x16" TILE WALL FINISH ON LOCATIONS NOTED ON A2.2
PTPT
PT
PT
PT
PT
PT
PT
PT
PT
PT PT
EXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE - RELOCATED
1 3/4" 78" 24"
9
WOOD
WOOD
WOOD
2S1
2S21 3/4" 84" WOOD60" PT WOOD
EXISTING DOOR & HARDWARE
PT
1 3/4" 84" WOOD36" PT WOOD PT
STAIRWELL
STAIRWELL
234 WASHROOM 1 3/4" 78" WOOD24" PT WOOD PT
EXISTING DOOR & HARDWARE w/ NEW 22"x30" GLAZING INSERTEXISTING DOOR & HARDWARE w/ TRANSFER LOUVRE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
3' FULL HEIGHT SIDE LITE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE
EXISTING DOOR & HARDWARE - RELOCATED
7
8
9
6'-6"
2'-8"
2'-6"
1'-10" 6'-6"
2'-8"
6'-6"
2'-8"
3'-0"
7'-0"
5
5'-0"
7'-0"
6
3'-0"
7'-0"
7
7'-0"
3'-0"
8
7'-0"
2'-8"
3'-0"
9
6'-6"
2'-4"
0'-4"
3'-0"
2'-0" 0'-
8"0'-
8"0'-
8"
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOORO.B.C ANALYSIS, LIFE SAFETY $ SCHEDULES
PR14-034
RLN
DCB
MAY 08 / 2015A2.1
1/16" = 1'-0"2 LIFE-SAFETY PLAN
TRAVEL DISTANCE 35'-1" 10.7M
D150101
0 ISSUED FOR TENDER MAY 08 2015
UP
SEMINAR
240
ACADEMIC
242-44
SERVICE
243
SEMINAR
246
ACADEMIC
245-47
ACADEMIC
248-50
SEMINAR
249ACADEMIC
251-53
M. WASHROOM
254
W. WASHROOM
255ACADEMIC
257-59
SHOWERS
256
PRAYER
258
SEMINAR
261
OFFICE
260
3A2.3
2W2
2W4
2W22W22W2
2W2
2W2
2W2
2W1
2W2
2W2
2W2
2W2
D240
D243D245D247D249D251D253D255D257D259D261
D260
D2C2
D258 D2SH
D254b
D254D250 D248 D246 D244 D242
D2C1CORRIDOR
2C3STAIR LANDING
2S2
D243b
3'-6"
3'-6"
RECESSED FIREEXTINGUISHER CABINET
RECESSED FIREEXTINGUISHER CABINET
2'-0"
2'-0"
2-W3
2-W3
2W4132'-5"5'-
0"
15'-4"
6'-6"
7A2.3
N.I.C.
AREA OFWORK
SEMINAR
246
A2.4
18
17
16
19
2W2
D246
12'-8
"
15'-4"
WHITEBOARD TYPE 1249 SIM.
SIM.
SIM.
260
261
WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)
NEW VCTFLOORING
ACADEMIC
242-44A2.4
4
57
6
WHITEBOARD TYPE 1
2W2
245-47
248-50
SIM.
SIM.
SIM.
SIM.
251-53
257-59
WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)
NEW VCTFLOORING
17'-4
"
23'-4"
BULKHEAD ABOVE(SEE STRUCT DWG.)
SEMINAR
240A2.4
8
911
10
2W2
D240
12'-8
"
15'-4"
WHITEBOARD TYPE 1
WHITEBOARD TYPE 2(LOCATION TO BE VERIFIED)
NEW VCTFLOORING
2W2
BUILD TO FIT NEW ENCLOSUREAROUND EXISTING PIPING.
VERIFY DIMENSIONS ON SITE.
1'-2"
1'-8"
SERVICE
243
A2.4 15
14
13
12
2W4
D243
D243b
12'-8
"
15'-4"
4'-0"
7'-2"7'-8"
2'-6"
7'-8"
2'-8"
5'-2"
N.I.C.
SEE ELECTRICAL DWG. FOR NEW FIXTURES & LIGHTING
2-W2
WALL TYPE LEGEND
2-W1
INTERIOR - NEW AIR RETURN CHASE
5/8" TYPE 'X' GYPSUM WALL BOARD250S162-43 STEEL STUDS @ 16" O/C
INTERIOR PARTITION - NEW 3 1/2"
5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C3 1/2" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD
2-W3 INTERIOR - NEW PLUMBING CHASE
5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C
2-W4 INTERIOR - NEW 6" INFILL WALL
5/8" TYPE 'X' GYPSUM WALL BOARD600S162-43 STEEL STUDS @ 16" O/C6" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD
7'-2
1/2"
3'-4"0'-2
1/2"
0'-6"
6'-8"
0'-4
1/2"
5/8" TYPE 'X' GYPSUM WALL BOARD
350S162-43 STEEL STUDS
ELECTRICAL CONDUIT
SHEET METAL
8" x16" VENT(SEE MECH.)
8" x16" VENT(SEE MECH.)
6" x22" INSULATEDDUCT (SEE MECH.)
2W2
EXISTING BLOCKWALL
1'-4"
6'-0"
0'-8"
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOOR ACADEMICPLAN, ENLARGED PLANS, SECTION DETAILS
PR14-034
RLN
DCB
MAY 08 / 2015A2.3
1/8" = 1'-0"1 SECOND FLOOR PLAN - ACADEMIC
1" = 100'-0"9 KEY PLAN - SECOND FLOOR
1/4" = 1'-0"4 ENLARGED PLAN - SEMINAR ROOM A
1/4" = 1'-0"5 ELNLARGED PLAN - ACADEMIC ROOM
1/4" = 1'-0"6 ENLARGED PLAN - SEMINAR ROOM B
1/4" = 1'-0"8 ENLARGED PLAN - SERVICE ROOM
1/8" = 1'-0"2 REFLECTED CEILING PLAN - ACADEMIC
1/2" = 1'-0"3 SECTION @ HALLWAY
1/2" = 1'-0"A2.37 AIR RETURN CHASE SECTION
D150101
0 ISSUED FOR TENDER MAY 08 2015
A2.52
1
4
3
2W1
11'-4" 3'-7 1/2"
7'-2"
5'-2"
M. WASHROOM
254
10'-1
0"
15'-4"
NEW TOILET PARTITIONSFINISH WALL WITH 4"x16"TILE
NEW VCTFLOORING
A2.5
5
6
7
8
6'-4"
8'-6"
7'-1"
3'-4"
12'-8
"
W. WASHROOM
255
2-W3FINISH WALL WITH 4"X16"TILE ABOVE COUNTERTOPELEVATION
NEW TOILET PARTITIONS
NEW VCTFLOORING
20A2.4
PRAYER
258
A2.5
11
12
9
10
2W2
11'-4"
17'-4
"
NEW VCTFLOORING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
AIRRETURNCHASE
VENT
6'-9" 5'-3 1/2"
4'-3"
2'-10
1/2
"
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASE VCT
PAINTED CONCRETECEILING
TYPE 1 -EPSON WHITEBOARD - 96"MODEL V12H468001MOUNTING HT. TO BEVERIFIED 8'-
0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETE CEILING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETE CEILING
AIRRETURNCHASE
VENT
TYPE 1 -EPSON WHITEBOARD - 96"MODEL V12H468001MOUNTING HT. TO BEVERIFIED
6'-9" 3'-0 1/2"
4'-3"
2'-10
1/2
"
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETE CEILING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
NEW PIPE ENCLOSURE
2W2
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASE
VCT
PAINTED CONCRETECEILING
AIRRETURNCHASE
6'-9"2'-4 1/2"
TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED
6'-0" MIN.
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
8'-0"
0'-4
1/2"
0'-4"
PAINTEDGWB
RUBBER BASEVCT
PAINTED CONCRETECEILING
PAINTEDBLOCK
0'-0
1/2"
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
AIRRETURNCHASE
0'-4"
8'-0"
VENT
2'-10 1/2" 6'-9"
4'-3"
2'-10
1/2
"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETE CEILING
AIRRETURNCHASE
0'-4"
8'-0"
TYPE 1 -EPSON WHITEBOARD - 96"MODEL V12H468001MOUNTING HT. TO BEVERIFIED
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0"
TYPE 2 -WHITEBOARDLOCATION &MOUNTING HT. TO BEVERIFIED
SUPPORT BRACKET @ 36" O.C.MFR. RAKKS, MODEL EH-1824CUT TO SUIT
1'-6"
1" POSTFORMEDLAMINATED COUNTERTOP
SOLID BLOCKING BETWEENSUPPORT BRACKETS0'-
4"
3" X 3/4" CLEAT
4" X 3/4" APRON
1'-6"
2'-8"
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOORENLARGED PLANS & INTERIOR ELEVATIONS
PR14-034
RLN
DCB
MAY 08 / 2015A2.4
1/4" = 1'-0"1 ENLARGED PLAN - MENS WASHROOM
1/4" = 1'-0"2 ENLARGED PLAN - WOMENS WASHROOM
1/4" = 1'-0"3 ENLARGED PLAN - PRAYER ROOM
1/4" = 1'-0"A2.44 ELEVATION 4
1/4" = 1'-0"A2.45 ELEVATION 5
1/4" = 1'-0"A2.46 ELEVATION 6
1/4" = 1'-0"A2.47 ELEVATION 7
1/4" = 1'-0"A2.48 ELEVATION 8
1/4" = 1'-0"A2.49 ELEVATION 9
1/4" = 1'-0"A2.410 ELEVATION 10
1/4" = 1'-0"A2.411 ELEVATION 11
1/4" = 1'-0"A2.412 ELEVATION 12
1/4" = 1'-0"A2.413 ELEVATION 13
1/4" = 1'-0"A2.414 ELEVATION 14
1/4" = 1'-0"A2.415 ELEVATION 15
1/4" = 1'-0"A2.416 ELEVATION 16
1/4" = 1'-0"A2.417 ELEVATION 17
1/4" = 1'-0"A2.418 ELEVATION 18
1/4" = 1'-0"A2.419 ELEVATION 19
1" = 1'-0"A2.420 COUNTER DETAIL
D150101
0 ISSUED FOR TENDER MAY 08 2015
VCT
PAINTED CONCRETECEILING
8'-0"
PAINTEDBLOCK
VCT
PAINTED CONCRETECEILING
8'-0"
VCT
PAINTED CONCRETECEILING
2'-8"1'-8" 2'-6"
2'-0"
8'-0"
CERAMIC TILE FINISHNOT SHOWN
PAINTEDBLOCK
VCT
PAINTED CONCRETECEILING
8'-0"
2'-8"
VCT
PAINTED CONCRETECEILING
2'-10"2'-9 1/2"1'-4"
PAINTEDBLOCK8'-
0"
CERAMIC TILE FINISHNOT SHOWN
PAINTEDBLOCK
VCT
PAINTED CONCRETECEILING
2'-8"
8'-0"
PLUMBINGCHASE PAINTED
BLOCK
VCT
PAINTED CONCRETECEILING
8'-0" PAINTED
BLOCK
VCT
PAINTED CONCRETECEILING
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
AIRRETURNCHASE
0'-4"
8'-0"
VENT
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
8'-0"
0'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
AIRRETURNCHASE8'-
0"
0'-4"
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDGWB
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
2W4
8'-0"
CONDUITENCLOSURE
VENT VENT VENT VENT VENT VENT
AIR RETURN VENT(COORDINATE w/ MECHANICAL DWG.)
RUBBERBASE
2W4
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCK
PAINTEDBLOCKPAINTED
GWB
8'-0"
CONDUITENCLOSURE
VENT VENT VENT VENT VENT
AIR RETURN VENT(COORDINATE w/ MECHANICAL DWG.)
RUBBERBASE
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
1/4" = 1'-0"
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOOR INTERIOR ELEVATIONS
PR14-034
RLN
DCB
MAY 08 / 2015A2.5
1/4" = 1'-0"A2.51 ELEVATION 1
1/4" = 1'-0"A2.52 ELEVATION 2
1/4" = 1'-0"A2.53 ELEVATION 3
1/4" = 1'-0"A2.54 ELEVATION 4
1/4" = 1'-0"A2.55 ELEVATION 5
1/4" = 1'-0"A2.56 ELEVATION 6
1/4" = 1'-0"A2.57 ELEVATION 7
1/4" = 1'-0"A2.58 ELEVATION 8
1/4" = 1'-0"A2.5
9 ELEVATION 9 1/4" = 1'-0"A2.5
10 ELEVATION 10 1/4" = 1'-0"A2.5
11 ELEVATION 11 1/4" = 1'-0"A2.5
12 ELEVATION 12
1/4" = 1'-0"13 NORTH-WEST CORRIDOR ELEVATION
1/4" = 1'-0"14 SOUTH-EAST CORRIDOR ELEVATION
D150101
0 ISSUED FOR TENDER MAY 08 2015
UP
UP
OFFICE
238
OFFICE
236
RECEPTION
228-30
STAFF
227-29
OFFICE
235
OFFICE
237
OFFICE
239
2W22W2
2W22W22W2
2W1
2W1
D237
D239
D239a
D2C2
D2E1
D2C1
D236D238 D228D2S1
D227D231D235
2W4
2W4
STAIR LANDING
2S1CORRIDOR
2C1
CORRIDOR
2C2D234
MECHANICAL
239a
AREA OFWORK
A2.6
8
9
10
11
OFFICE
239
9'-4"
10'-0
"
4'-4"2W1
D239
A2.6
14
15
12
13
OFFICE
236
9'-4"
14'-6
"
2W2
D236
235 SIM.
SIM.
SIM.
237
238A2.7
6
8
5
7RECEPTION
228-30
9'-4" 10'-0"
14'-6
"4'-
4"
2W2
D228
BULKHEAD ABOVE(SEE STRUCT. DWG)
2W4
A2.7
3
42
1
STAFF
227-29
14'-2"5'-6"
4'-4"
10'-0
"4'-
6"
8'-0"
2W1
2W4
NEW COAT RACK
NEW COUNTERTOP& CABINETRTY
D227D231
BULKHEAD ABOVE(SEE STRUCT. DWG)
8'-0"
PAINTED BLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0" PAINTED BLOCK
RUBBER BASEVCT
PAINTEDCONCRETECEILING
PAINTEDGWB
0'-4"
8'-0"
D239PAINTEDGWB
RUBBER BASEVCT
PAINTED CONCRETECEILING
PAINTEDBLOCK
0'-4"
8'-0" PAINTED
BLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0" PAINTED
BLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
2'-1"
AIRRETURNCHASE
VENT
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
AIRRETURNCHASE
0'-4"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0" PAINTED
BLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
2-W2
WALL TYPE LEGEND
2-W1
INTERIOR - NEW AIR RETURN CHASE5/8" TYPE 'X' GYPSUM WALL BOARD250S162-43 STEEL STUDS @ 16" O/C
INTERIOR PARTITION - NEW 3 1/2"5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C3 1/2" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD
2-W3 INTERIOR - NEW PLUMBING CHASE5/8" TYPE 'X' GYPSUM WALL BOARD350S162-43 STEEL STUDS @ 16" O/C
2-W4 INTERIOR - NEW 6" INFILL WALL5/8" TYPE 'X' GYPSUM WALL BOARD600S162-43 STEEL STUDS @ 16" O/C6" ABSORPTIVE MATERIAL5/8" TYPE 'X' GYPSUM WALL BOARD
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOOR ADMINISTRATIONPLANS, ENLARGED PLANS, ELEVATIONS
PR14-034
RLN
DCB
MAY 08 / 2015A2.6
1/8" = 1'-0"5 SECOND FLOOR PLAN - ADMINISTRATION
1" = 100'-0"1 KEY PLAN - SECOND FLOOR
1/8" = 1'-0"2 REFLECTED CEILING PLAN - ADMINISTRATION
1/4" = 1'-0"3 ENLARGED PLAN - OFFICE A
1/4" = 1'-0"4 ENLARGED PLAN - OFFICE B
1/4" = 1'-0"6 ENLARGED PLAN - RECEPTION
1/4" = 1'-0"7 ENLARGED PLAN - STAFF
1/4" = 1'-0"A2.68 ELEVATION 8
1/4" = 1'-0"A2.69 ELEVATION 9
1/4" = 1'-0"A2.610 ELEVATION 10
1/4" = 1'-0"A2.611 ELEVATION 11
1/4" = 1'-0"A2.612 ELEVATION 12
1/4" = 1'-0"A2.613 ELEVATION 13
1/4" = 1'-0"A2.614 ELEVATION 14
1/4" = 1'-0"A2.615 ELEVATION 15
D150101
0 ISSUED FOR TENDER MAY 08 2015
8'-0"
9'-4"10'-4"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETECEILING
0'-4"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETECEILING
PAINTEDBLOCK
0'-4"
8'-0" PAINTED
BLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
VENT
ADJ. SHELF
ADJ. SHELF ADJ. SHELF
ADJ. SHELF
2'-9" 2'-9"
2'-0"
2'-0"
3'-0
1/2"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
EXISTINGBRICK
0'-4"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTEDCONCRETECEILING
0'-4"
AIRRETURNCHASE
VENT
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
AIRRETURNCHASE
8'-0"
PAINTEDBLOCK
RUBBER BASEVCT
PAINTED CONCRETECEILING
0'-4"
4"
2'- 0
"
1'-1 3/4"
1'-10 1/2"
3"
2'-0"
3'-1
1/2"
4"
PROVIDE DOOR PULLS & LOCKS
32mm SYSTEM HOLES
UNFINISHED TOEKICK
SINK
PROVIDE DOOR PULL & LOCKS
32mm SYSTEM HOLES
24
13
1013
2
3
21
2
4
PROJECT:
DRAWING TITLE:
DCSC PROJECT NO. OWNER PROJECT NO. REV.
SCALE
CHECKED BY:
DRAWN BY:
DATE:
DRAWING NO.
DCSC LIMITED ARCHITECT & ENGINEERTHUNDER BAY ONTARIO
NO. REVISIONS DATE
As indicated
LAKEHEAD UNIVERSITYPRETTE RESIDENCE ELP RENOVATION
SECOND FLOOR RENOVATEDINTERIOR ELEVATIONS
PR14-034
RLN
DCB
MAY 08 / 2015A2.7
1/4" = 1'-0"A2.71 ELEVATION 1
1/4" = 1'-0"A2.72 ELEVATION 2
1/4" = 1'-0"A2.73 ELEVATION 3
1/4" = 1'-0"A2.74 ELEVATION 4
1/4" = 1'-0"A2.75 ELEVATION 5
1/4" = 1'-0"A2.76 ELEVATION 6
1/4" = 1'-0"A2.77 ELEVATION 7
1/4" = 1'-0"A2.78 ELEVATION 8
1" = 1'-0"MILLWORK - STAFF ROOM CABINET9
MATERIAL LEGEND
19mm MAPLE VENEER CORE PLYWOOD c/w3MM SOLID MAPLE HARDWOOD EDGING
19mm WHITE MELAMINE c/w PVC TAPE TOMATCH DOOR & DRAWER
19mm WHITE MELAMINE c/w MATCHING PVCTAPE
6mm PREFINISHED WHITE HARDBOARD
25mm PARTICLE BOARD c/w PLASTICLAMINATE BACKER, 3mm PVC EDGING
19MM PARTICLE BOARD CLAD WITH PLASTICLAMINATE ON EXPOSED FACE ONLY c/w 3mmPVC MATCHING EDGING
1-
1-
1-
1-
1-
1-
D150101
0 ISSUED FOR TENDER MAY 08 2015
SEM
INAR
240
ACAD
EMIC
242-4
4
SERV
ICE
243
SEM
INAR
246
ACAD
EMIC
245-4
7
ACAD
EMIC
248-5
0
SEM
INAR
249
ACAD
EMIC
251-5
3
M. W
ASHRO
OM
254
W. W
ASHRO
OM
255
ACAD
EMIC
257-5
9
SHO
WERS
----
PRAYER
258
SEM
INAR
261
OFFIC
E
260
HALLW
AY262
STAIRW
ELL
263
OFFIC
E
238
OFFIC
E
236
ADM
IN.
228-3
0
STAFF
227-2
9
OFFIC
E
235
OFFIC
E
237
OFFIC
E
239
Web: w
ww.sostratus.ca
e-mail: info@
sostratus.caFx: (8
07) 3
46-1
344Ph: (8
07) 3
46-1
340
Canada P7A 4L8
Thunder Bay, O
ntario208 - 7
3 N
. Cum
berland StreetSostratus Engineering Ltd.
EXCH
CORRIDOR
EXCH
EX
EXCH
EX
EX
RM
EXEX
NEW EX
RM
EXCH
EXCH
EX EX
EXCH
EXCH
EXCH
EX
RM
AVx2
AV
EX EX
EXCH
EXCH
AVx2
AVAVx2
AV
AVx2
AV
AVx2
AV
EX EX
EXCH
EXCH
EX EX
EXCH
EXCH
EX
EXCH
EXCH
EXCH
EX
RMCH
RMCH
RMCH
RMCH
EX
EXCH
EXCH
AVx2
AV
EX
EX
EXCH
EXCH
AVx2
AV
AVx2
AV
AVx2
AV
EX
EX
EXCH
RM
EX
EXCH
EXCH
EXCH
EXCH
EX
EX
WIFIAVx2
WIFIAVx2
WIFIAVx2
WIFIAVx2
WIFIAVx2
AVx2
WIFI
AVx2
WIFI
AVx2
WIFI
AVx2
WIFI
AVx2
WIFI
NEW DATA CABLINGCONDUIT, SEEPOWER NOTE 5.
3/4" DIA CONDUIT FOR NEWDATA CABLING INTO NEWCLASSROOM, TYPICAL.
OFFICE
260
SEMINAR
261
ACADEMIC
257-59
W. WASHROOM
255
ACADEMIC
251-53
SEMINAR
249
ACADEMIC
245-47
SERVICE
243
SEMINAR
240
ACADEMIC
242-44
SEMINAR
246
ACADEMIC
248-50
M. WASHROOM
254
SHOWERS
256
PRAYER
258
EX
EX
EX EX EX EX
EX
EX EX
EX
EX EX
EX
EX EX
EX
RM RM RM
RM
RMEX
RM
EX
RM
RM
RM
EXISTING PANEL 'A',POWER NOTE 7.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
NEW HYDRONIC HEATING,SEE NOTE 4.
NEW HYDRONIC HEATING, SEE NOTE 4.
EXISTING DEVICESTO REMAIN
EXEX
HRV-1A-3/4/5
EX EX
FIELD LOCATE NEW SMOKEDETECTORS TO AVOID NEWDUCTWORK. REFER TO MECHDRAWINGS, TYPICAL.
A-1
A-1A-1
A-1
A-1
A-2
A-2
A-2
A-2
A-2
SEE POWERNOTE 8.
SEE POWERNOTE 8.
SECOND FLOOR ACADEMIC AREA POWER NOTESALL EXISTING TELEPHONE DEVICES, WIRING AND TERMINAL STRIPS TO BEREMOVED.
ALL EXISTING DATA OUTLETS TO REMAIN.
ALL EXISTING CABLE TELEVISION DEVICES AND WIRING TO BE REMOVED.
NEW HYDRONIC HEATING TO BE INSTALLED ALONG EXTERIOR WALLS OFAREA AT FLOOR. REFER TO MECHANICAL DRAWINGS FOR EXACTLOCATIONS. RELOCATE DEVICES AS REQUIRED.
1.
2.
3.
4.
2" DIA CONDUIT FOR NEW DATA CABLING INTO CLASSROOMS. CONDUITMOUNTED IN NEW ARCHITECTURAL RACEWAY ABOVE DOORS. REFER TOARCHITECTRUAL DETAILS. PROVIDE JUNCTION BOXES WHERE REQUIRED,COORDINATE JUNCTION BOX SIZES WITH ARCHITECTURAL DETAILS.
5.
REMOVE ALL DEVICES IN DEMOLISHED WALLS, MAINTAIN EXISTING CIRCUITINTEGRITY.
6.
TO MAKE ROOM FOR NEW CIRCUITS IN PANEL 'A' ELECTRICAL CONTRACTORSHALL ADD TANDEM BREAKERS TO SUIT PANEL.
7.
PROVIDE LV POWER FOR ALL NEW URNIALS AND LAVS IN WASHROOMS. FIELDLOCATE, PROVIDE TRANSFORMER, COODINATE WITH MECHANICAL. CONNECTTO CIRCUIT 'A-6'.
8.
A-1
PHASE A PHASE B PHASE C
VA WIRE ANDCONDUIT SIZE
VOLTSPOLESSIZE
BREAKERCIRCUIT USE
CCT. No.
A-2
A-3
A-4
A-5
N E W P A N E L ' A ' C I R C U I T S
NOTES:- RE-USE EXISTING CIRCUITS, GROUP THE FIXTURES/DEVICES AS SHOWN IN THIS SCHEDULE.
600
600
762
762
2c#12 AWG IN EMT
2c#12 AWG IN EMT
3c#10 AWG IN EMT
762
NEW AV RECEPTACLES
NEW AV RECEPTACLES
NEW HRV-1
15A 1 120
15A 1 120
20A 3 208
A-6 120 2c#12 AWG IN EMTLV POWER, MECHANICAL CONTOL POWER 15A 1 120
MAY 8/2015GENERAL SPECIFICATIONS1. INSTALLATION SHALL BE IN ACCORDANCE WITH THE ONTARIO HYDRO
ELECTRICAL SAFETY CODE LATEST EDITION & ALL OTHER APPLICABLECODES & REGULATIONS.
2. ALL EQUIPMENT SHALL BE NEW AND CSA CERTIFIED.
3. ELECTRICAL CONTRACTOR SHALL SUPPLY EQUIPMENT AS SPECIFIED ASWELL AS ANY MISCELLANEOUS TO COMPLETE THE WORK.
4. IDENTIFY ELECTRICAL EQUIPMENT WITH PROPER NAMEPLATES. IDENTIFY ALLWIRING, MAINTAIN PHASE SEQUENCE & COLOUR CODING.
5. CONTRACTOR TO FURNISH CERTIFICATES OF ACCEPTANCE FROM THEELECTRICAL INSPECTION DEPARTMENT UPON COMPLETION OF WORK TO THEENGINEER. REVERIFY F/A SYSTEM BY QUALIFIED PERSONNEL. CONDUCTAUDITORY TEST UPON COMPLETION.
6. ALL WIRING SHALL BE MIN. #12 AWG Cu. IN EMT (UNLESS OTHERWISENOTED).
7. INSTALL INSULATED GREEN BONDING CONDUCTOR IN ALL EMT CONDUIT.
8. ALL WIRING SHALL BE CONCEALED FROM VIEW UNLESS OTHERWISENOTED.
9. ELECTRICAL CONTRACTOR SHALL MAKE A PERSONAL SITE VISIT ANDCONFIRM ALL QUANTITIES/LOCATION/MOUNTING PRIOR TO SUBMITTINGQUOTE.
10. CONTRACTOR SHALL REPAIR ALL SURFACES DAMAGED DUE TO WORKPERFORMED.
11. CONTRACTOR SHALL VERIFY ALL DIMENSIONS, DO NOT SCALEDRAWING.
12. ALL MATERIALS REMOVED AND MADE REDUNDANT BY THIS WORK (UNLESSINDICATED OTHERWISE) SHALL BECOME PROPERTY OF OWNER.
13. MOUNTING HEIGHTS FOR DEVICES AS PER CODE REQUIREMENTS, UNLESSOTHERWISE NOTED.
14. COORDINATE COLOUR FOR ALL WALL PLATES, RECEPTACLES, SWITCHESAND DEVICES WITH OWNER.
15. MOUNT ALL EMERGENCY LIGHTING AT 7'-0" ABOVE FINISHED FLOOR.PROVIDE RECEPTACLE ABOVE CEILING AS REQUIRED.
16. COORDINATE ALL LIGHT FIXTURE AND RECEPTACLE INSTALLATION INMILLWORK WITH CABINET BUILDER.
17.
19. ELECTRICAL CONTRACTOR TO SUPPLY AND INSTALL ALL FUSED AND NON-FUSED DISCONNECTS AS REQUIRED FOR ALL MECHANICAL EQUIPMENTINDICATED ON ELECTRICAL AND MECHANICAL DRAWING SETS. AMPERAGE,VOLTAGE AND NUMBER OF POLES TO BE CONFIRMED WITH MANUFACTURER'SLITERATURE.
20. COMPLETE TYPEWRITTEN PANEL SCHEDULES ARE TO BE PROVIDED FOR ALLPANELS. ALL LOADS FED FROM RELOCATED EXISTING CIRCUITS ARE TO BEDETERMINED AND INCLUDED IN PANEL SCHEDULES.
18. THE INTENT OF THIS PROJECT IS INSTALL A COMPLETE LIGHTING DESIGN.IF SWITCHING FOR AN AREA IS NOT SHOWN, THE ELECTRICALCONTRACTOR SHALL PROVIDE SWITCHING.
21. ALL ELECTRICAL EQUIPMENT WITHIN SPRINKLERED ROOMS SHALL BEEQUIPPED WITH HOODS SUITED FOR THE APPLICATION. IF HOODS ARE NOTPROVIDED BY THE FACTORY OR IT IS FOR AN EXISTING PIECE OFEQUIPMENT, IT SHALL BE THE ELECTRICAL CONTRACTORSRESPONSIBILITY TO SUPPLY AND INSTALL THESE HOODS ON NEW OREXISTING EQUIPMENT AS REQUIRED.
22. ALL CEILING SPACES IN RENOVATION AREAS ACT AS RETURN AIRPLENUMS. ALL CABLING IN CEILING SPACE MUST HAVE AN FT6 FIRERATING OR BE COMPLETELY ENCLOSED IN CONDUIT.
GENERAL DEMOLITION NOTES1. REMOVE ALL UNNECESSARY EXISTING ELECTRICAL EQUIPMENT, WIRING, &
FIXTURES IN THOSE PORTIONS OF THE EXISTING BUILDING WHICH ARE BEINGREMODELED OR DEMOLISHED. THE ELECTRICAL CONTRACTOR SHALLREMOVE ALL REDUNDANT EQUIPMENT FROM SITE. ANY ELECTRICALEQUIPMENT IN REMODELED SECTIONS OR IN STRUCTURES REMOVED ORALTERED, ADJACENT TO NEW WORK, NECESSARY FOR THE OPERATION OFEXISTING BUILDING, SHALL BE RELOCATED AS NECESSARY. ALL EXISTINGEQUIPMENT REUSED SHALL BE MADE GOOD AND GUARANTEED. REVISEPANEL SCHEDULES TO SUIT.
3. REFER TO ARCHITECTURAL DEMOLITION DRAWINGS AND NOTES ANDCOORDINATE AS REQUIRED.
2. ALL REDUNDANT EQUIPMENT MAY NOT APPEAR IN DRAWING SET. IT IS THERESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO REMOVE ALLREDUNDANT EQUIPMENT AND ADHERE TO DEMOLITION NOTE #1 IN ALLCASES.
PROVIDE DEDICATED 1P-15A BREAKER FOR EXIT SIGN POWER.
23. ELECTRICAL CONTRACTOR TO PROVIDE AND INSTALL 20A GFI NEMA 5-20RCONVENIENCE RECEPTACLE(S) WITHIN 7.5m OF ALL ROOFTOP MOUNTEDMECHANICAL EQUIPMENT (HEATING, VENTILATION, AIR CONDITIONINGUNITS). ALL RECEPTACLES TO BE FED FROM DEDICATED 1P-20A CIRCUIT(S),AND MOUNTED IN WEATHERPROOF BACKBOX W/ SPRING-LOADED COVER,MINIMUM 750mm ABOVE FINISHED ROOF.
LIGHTING IDENTIFICATION LEGEND
LED TROFFER FIXTURE, 120V, 43W, 3500°, 4100 LUMEN,12"x48"PHILIPS CFI DAY-BRITE SERIESCAT# 1-DL-G-41L-835-4-D-UNV
T1
TOGGLE SWITCH, BACK/SIDE WIRED, 15A, 120/277V,LEVITON CAT. # 1201 OR EQUAL.
BARRIER-FREE DOOR OPERATOR AND ASSOCIATEDPUSHBUTTONS. ALL POWER AND CONTROL WIRING BYELECTRICAL CONTRACTOR. INSTALL CONDUIT AND RECESSEDBOXES FOR PUSHBUTTONS AS REQUIRED. COORDINATE WITHDOOR HARDWARE SUPPLIER/INSTALLER.
DUPLEX RECEPTACLE
FIRE ALARM PULLSTATION
LED SURFACE-MOUNT FIXTURE, 120V, 50W, 3500°,12"x48", MATTE WHITE FINISH, FLAT END CAP,KENALL MILLENIUM STRETCH SERIESCAT# MLHA12-48-F-MW-PP-45L35K-DCC-1-120
S1
LED WALL-MOUNT FIXTURE, 120V, 25W, 3500°,8"x24", MATTE WHITE FINISH, FLAT END CAP,C/W CORNER MOUNT BRACKETKENALL MILLENIUM STRETCH SERIESCAT# MLHA8-24-F-MW-PP-25L35K-DCC-1-120-CMB
S2
THREE-WAY TOGGLE SWITCH, BACK/SIDE WIRED, 15A,120/277V, LEVITON CAT. # 1203 OR EQUAL.
3W
LED "RUNNING MAN" EXIT SIGN W/ PICTOGRAM SYMBOLSCONFORMING TO ISO 7010. EXTRUDED ALUMINUM FRAME W/CLEAR POLYCARBONATE PANELS AND PICTOGRAM FILMS.SELF-POWERED WITH NICKLE-CADMIUM BATTERY SIZED FOR2 HOURS BACKUP. UNIVERSAL VOLTAGE (120V-347V).SINGLE OR DOUBLE FACED TO SUIT AND PICTOGRAM FILMSTO DENOTE EXIT DIRECTIONS AS NOTED ON DRAWINGS.EMERGI-LITE# EA SERIES
'EM' DENOTES A LIGHT FIXTURE FED FROM EMERGENCYPOWER PANEL 'EM' LOCATED IN BASEMENT.
EM
POWER/SYSTEMS IDENTIFICATION LEGEND
GFI RECEPTACLE
20A GFI RECEPTACLE20A
NEW COMMUNICATIONS OUTLET. PROVIDE 3/4" EMTRACEWAY TO CEILING SPACE C/W PULL CORD.
EXISTING VOICE/DATA OUTLET
EXISTING TELEPHONE OUTLET
EXISTING CABLE TELEVISION OUTLET
FIRE ALARM BELL
FIRE ALARM HEAT DETECTOR
FIRE ALARM SMOKE DETECTOR
'AV' DENOTES DEVICES FOR AUDIO/VISUAL EQUIPMENT TOBE MOUNTED AT HIGH LEVEL, NEAR CEILING.
AV
'CH' DENOTES DEVICE WALL-MOUNTED AT COUNTERHEIGHT.
CH
'EX' DENOTES EXISTING DEVICE TO BE REMOVED ANDREPLACED WITH NEW.
EX
'RM' DENOTES EXISTING DEVICE TO BE REMOVED C/W ALLWIRING TO SOURCE. MAINTAIN CIRCUIT INTEGRITY.
RM
'RL' DENOTES DEVICE TO BE REMOVED AND REUSED IN NEWLOCATION. EXTEND WIRING AND CONDUIT AS REQUIRED.REFER TO DEMOLITION PLANS, RENOVATION PLANS, GENERALELECTRICAL CONSTRUCTION NOTES AND SPECIFICATIONS. - REUSE OF LIGHTING FIXTURES WILL REQUIRE THE FIXTURE BE CLEANED, RELAMPED AND BALLAST CHANGED. - RELOCATION OF FIRE ALARM SMOKE DETECTORS, HEAT DETECTORS AND PULLSTATIONS ARE TO BE REPLACED WITH NEW DEVICES AT NEW LOCATION.
RL
'RP' DENOTES EXISTING DEVICE TO BE REPLACED WITH NEW.RP
PLOT SCALE:
DRAWN BY:
APPROVED BY:PROJECT No.
DWG SCALE:
DATE ISSUED:
DRAWING TITLE
DWG No. REV.
DATEBYNo. DESCRIPTION
PROJECT TITLE
A.G. Engineering
Electrical Engineers
Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633
1:1
0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015
0
As indicated
Lakehead University
Second Floor Academic AreaPower Layout
May 2015
A111-15-001
E1-1
GAP
AG
Prettie Residence ELP Renovation
SECOND FLOOR ACADEMIC AREA - POWER LAYOUTSCALE 1:50
S1
CORRIDOR
RM
S1 S1
S1
S1
S1
S1S1
S1
S1
S1
S1
3W3W
S1S1
S1S1
S1S1
S1S1
S1S1
S1S1
S1S1
S1S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
3W3W3W3W
3W3W 3W3W
S2
3W
SHOWERS
256
PRAYER
258
OFFICE
260
SEMINAR
261
ACADEMIC
257-59
W. WASHROOM
255
M. WASHROOM
254
ACADEMIC
251-53
ACADEMIC
245-47
SERVICE
243
SEMINAR
240
ACADEMIC
242-44
ACADEMIC
248-50
SEMINAR
249
SEMINAR
246
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2
S2S2S2
S2
S2
S2
S2
RM
RM
EXISTINGLIGHTING TO
REMAIN
EXISTING LIGHTINGTO REMAIN
RM
EXISTING LIGHTINGTO REMAIN
EXISTING LIGHTINGTO REMAIN
S2
RM
RM
RM EXISTING LIGHTINGTO REMAIN
S2EM EM EM EM EMEM
S2
SECOND FLOOR ACADEMIC AREA LIGHTING NOTES1. CONNECT ALL NEW LIGHTING TO EXISTING LIGHTING CIRCUITS FOR
AREA, CONFIRM CIRCUIT LOADING, ADD CIRCUITS IF REQUIRED.
2. NEW CORRIDOR LIGHTING TO BE CONNECTED TO EXISTINGCORRIDOR LIGHTING CIRCUIT FOR POWER AND EXISTINGSWITCHING FOR CONTROL.
3. CORRIDOR LIGHTING TO BE MOUNTED BELOW ARCHITECTUALVALENCE, REFER TO ARCHITECTUAL DRAWINGS.
4. RUN NEW WIRING IN SURFACE-MOUNT RACEWAYS, CONCEALNEW WIRING IF POSSIBLE.
MAY 8/2015
PLOT SCALE:
DRAWN BY:
APPROVED BY:PROJECT No.
DWG SCALE:
DATE ISSUED:
DRAWING TITLE
DWG No. REV.
DATEBYNo. DESCRIPTION
PROJECT TITLE
A.G. Engineering
Electrical Engineers
Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633
1:1
0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015
0
As indicated
Lakehead University
Second Floor Academic AreaLighting Layout
May 2015
A111-15-001
E1-2
GAP
AG
Prettie Residence ELP Renovation
SECOND FLOOR ACADEMIC AREA - LIGHTING LAYOUTSCALE 1:50
RMEX
EX
RM
RM
RM
RM
EX
RM
EX
RM
RM
W/R
STAIRCORRIDOR H
RM
CLOSET
EXISTINGLIGHTING TO
REMIAN
EXISTINGLIGHTING TO
REMIAN
TIE NEW CORRIFORLIGHTING INTO EXISTINGCIRCUIT & SWITCHING.
OFFICE
238
OFFICE
236
RECEPTION
228-30
OFFICE
239
OFFICE
237
OFFICE
235
STAFF
227-29
EF-2
EF-1B-6
EM EM
W/R
EX
CH20A
CH20A
RM
EX
EXRM
EXEX
EX
EX
EX
RM
EX
EX
EX
EX
EX
STAIRCORRIDOR H
RM
EX
RM
EX
EX EX
EX EX EX
EX
EX RLRELOCATE PULLSTATION TOACCOMODATE NEWSIGHLIGHT WINDOW.
EX
EXISTING PANEL 'B'POWER NOTE 6.
POWERNOTE 5.
RM
EX
EX
EX
RM
EX
RM
RECEPTION
228-30
OFFICE
236
OFFICE
238
OFFICE
239
OFFICE
237
OFFICE
235
STAFF
227-29
RP
HRV-2B-7
CONDENSATEPUMP B-7
4kW DUCTHEATER HC#3B-4/5
EX EX EX EX EX
EXEXEXEX
EX
B-1
B-2
B-2B-2
B-2
B-2
B-1
B-1
POWER NOTE 7.
MECH CONTROLSPOWER, B-3
B-1
B-8 B-8POWER NOTE 8.
SECOND FLOOR ADMIN AREA LIGHTING NOTES1. CONNECT ALL NEW LIGHTING TO EXISTING LIGHTING CIRCUITS FOR
AREA, CONFIRM CIRCUIT LOADING, ADD CIRCUITS IF REQUIRED.
2. NEW CORRIDOR LIGHTING TO REPLACE EXISTING WALL-MOUNTLIGHT FIXTURES. CONNECT TO EXISTING CIRCUIT FOR POWER ANDSWITCHING FOR CONTROL.
3. RUN NEW WIRING IN SURFACE-MOUNT RACEWAYS, CONCEAL NEWWIRING IF POSSIBLE.
SECOND FLOOR ADMIN AREA POWER NOTESALL EXISTING TELEPHONE DEVICES, WIRING AND TERMINALSTRIPS TO BE REMOVED.
ALL EXISTING DATA OUTLETS TO REMAIN.
ALL EXISTING CABLE TELEVISION DEVICES AND WIRING TO BEREMOVED.
1.
2.
3.
4. REMOVE ALL DEVICES IN DEMOLISHED WALLS, MAINTAINEXISTING CIRCUIT INTEGRITY.
5. 2x 2" EMT CONDUIT FROM CRAWLSPACE FOR DATA CABLING.
6. TO MAKE ROOM FOR NEW CIRCUITS IN PANEL 'B' ELECTRICALCONTRACTOR SHALL ADD TANDEM BREAKERS TO SUIT PANEL.
7. PROVIDE 20A T-SLOT RECEPTACLE FOR CONDENSATE PUMP.
8. PROVIDE 20A T-SLOT RECEPTACLE FOR HRV-2.
B-1
PHASE A PHASE B PHASE C
VA WIRE ANDCONDUIT SIZE
VOLTSPOLESSIZE
BREAKERCIRCUIT USE
CCT. No.
B-2
B-3
B-4
B-5
B-6
N E W P A N E L ' B ' C I R C U I T S
NOTES:- RE-USE EXISTING CIRCUITS, GROUP THE FIXTURES/DEVICES AS SHOWN IN THIS SCHEDULE.
480
600
120
2000
2c#12 AWG IN EMT
2c#12 AWG IN EMT
2c#12 AWG IN EMT
2c#10 AWG IN EMT2000
NEW DATA RECEPTACLES
NEW RECEPTACLES
MECHANICAL CONTROLS
4kW DUCT HEATER HC#3
15A 1 120
15A 1 120
15A 1 120
30A 2 208
2c#12 AWG IN EMTEXHAUST FAN EF-1 15A 1 120 200
B-7
B-8
500 2c#12 AWG IN EMT
750 2c#12 AWG IN EMT
HRV-2 & CONDENSATE PUMP
20A GFI RECEPTACLES
15A 1 120
20A 1 120
MAY 8/2015
PLOT SCALE:
DRAWN BY:
APPROVED BY:PROJECT No.
DWG SCALE:
DATE ISSUED:
DRAWING TITLE
DWG No. REV.
DATEBYNo. DESCRIPTION
PROJECT TITLE
A.G. Engineering
Electrical Engineers
Thunder Bay Inc.1111 E. Victoria Ave., 2nd FlrThunder Bay, ON, P7C 1B7Phone : (807) 622-3654Cell: (807) 627-8194Fax: (807) 622-3633
1:1
0 ISSUED FOR PERMIT & TENDER GAP MAY 8 2015
0
As indicated
Lakehead University
Second Floor Administration AreaPower & Lighting Layout
May 2015
A111-15-001
E2-1
GAP
AG
Prettie Residence ELP Renovation
SECOND FLOOR ADMINSTRATION AREA - LIGHTING LAYOUTSCALE 1:50
SECOND FLOOR ADMINSTRATION AREA - POWER LAYOUTSCALE 1:50
top related