SSPPEECCIIFFIICCAATTIIOONN
AMS MU800 Mullion Drained Curtain Walling
The AMS MU800 mullion drained curtain walling system offers unique architectural design
features combined with market leading weather performance. The system is propriety
based and is suitable for both low & high rise applications. The system is visually complete
with a 55mm face width.
IntroductionThe suite of profiles consist of 35mm X 55mm, 63mm X 55mm, 99mm X 55mm, 126mm X
55mm, 146mm X 55mm, with a thermal isolator, EPDM gaskets, foil backed weather tape
and pressure plate allowing a thermally broken façade. There are a variety of external
finishing options available in aluminium face caps.
Thermal PerformanceAMS MU800 curtain walling is designed to offer the specifier excellent aluminium thermal u-
frame values in conjunction with the correct glass specification to achieve overall target u-
vales or equivalent energy ratings on specified projects.
ScopeThis specification defines materials, fabrication, paint finishes, and size limitations for curtain
walling.
MaterialsAluminium profiles are extruded from aluminium alloy 6063 T5 and T6 complying with
BS1474 – BS EN 12020-2:2001 / BS EN 755-9:2001.
Paint Finishes
Polyester Powder CoatingsAluminium profiles can be dual colour polyester powder coated to BS6496.
AMS offers in house painting with the following paint suppliers :
• Azko Nobel Interpon D
• Du Pont Alesta
• Beckers Powder
Decoral Aluminium profiles can be polyester powder coated with a woodgrain effect paint finish to
BS6496.
AnodisedAluminium profiles can be anodised to BS1615 or BS3987.
Architectural & Metal Sytems
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
SSPPEECCIIFFIICCAATTIIOONN
Architectural & Metal Sytems
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
ARCHITECTURAL & METAL SYSTEMS
FabricationThe AMS MU800 curtain walling system is designed as a stick system and frame members
such as mullions and transoms shall be fabricated in accordance with AMS technical
literature and transported to site as prepared components. The stick grid system shall be
assembled on the proposed facade area as per fabrication shop drawings and architects
instructions.
Mullions shall be square cut and profiles shall be joined specially with jointing spigots.
Mullions shall run the full height of the façade with transoms spanning in between and these
shall be notched and screw fixed to the mullion. Transoms shall have notched ends to
ensure a weather proof joint.
Fixing points should be advised by a structural engineer and relevant fixing brackets
approved so that all loads are transferred back to the main building structure. Low modulus
silicone shall be used throughout for weathering joints as recommended by the silicone
manufacturer.
GlazingGlass shall be set against extruded gaskets internally which are fitted into gasket grooves in
the mullions and transoms. Gaskets shall be to BS 4255: EPDM. The system can
accommodate 22mm, 24mm, 28 mm and 32mm double glazed insulating units. Glazing
shall be to BS 6262 and Building Regulations Document N.
InstallationAMS offer detailed installation instructions on all systems and these should be followed as
per AMS’s technical department’s recommendations.
StructureSection performance requirements must be calculated from site conditions and all loading
requirements. All structural profiles shall be designed so as the maximum deflection of any
member shall not exceed L/175 of its span and there shall be no evidence of any permanent
deformation once the load has been removed.
PerformanceTested to BS 6375-Part 1.Air Permeability - 600 Pa.Water Tightness - 600 Pa.Wind Resistance - 2400 Pa.
Tested to CWCT standards.Sequence B Test.
Insert Opening Vents & DoorsDetails and specification information for these insert products can be found in the window
and door section of AMS’s technical literature.
AMS MULLION DRAINED CURTAIN WALL SYSTEM
AMS Ltd. Wallingstown, Little Island, Co. Cork: Tel: 021 4705100 Fax: 021 4705198, E-mail: pohara@ams.ie, Web: www.ams.ie
1.1.01 B: Profile listing, Mullion/Transoms.
1.1.02 B: Profile listing, cappings.
1.1.03 D: Gaskets and accessories.
1.1.04 C: Accessories.
1.1.05 : Brackets.
1.1.06 : Ixx of Mullions sleeved.
1.1.07 : Profile assembly.
1.1.08 B: Gapping options.
1.1.09 B: Glazing options - Mullions.
1.1.10 C: Glazing options - Transoms
1.1.11 : System applications.
1.1.12 B: Typical head details.
1.1.13 B: Typical head detail into kingspan panels.
1.1.14 C: Typical cill details
1.1.15 B: Typical mid span fixing.
1.1.16 B: Typical mid span fixing.
1.1.17 A: Typical sash insert - 24mm.
1.1.18 B: Concealed sash detail.
1.1.19 B: Typical sash insert - 28mm.
1.1.20 B: Typical door head detail.
1.1.21 B: Typical jamb detail.
1.1.22 B: Typical door jamb detail.
1.1.23 B: Corner details.
1.1.24 B: Sloped glazing - head detail.
1.1.25 B: Sloped glazing - eaves detail.
1.1.26 B: Sloped glazing - jamb detail.
1.1.27 B: False mullion detail.
1.1.28 B: Typical ridge detail.
1.1.29 B: Typical ridge detail.
1.1.30 B: Double transom ridge detail
1.1.31 C: Sloped glazing - cill detail
1.1.32 A: Typical details MU899-60 (60mm transom)
1.1.33 A: Insert details
135
160
55
8
69
55
958
MU 800 SERIES MULLION DRAINED SYSTEMMullions and transomsScale NTS
Page : 1.1.01
13110
6
55
153
178
180
128
162
99
133 63 97
35
69
55
55
55
55
55
MU 899TRANSOM
MU 894TRANSOM
MU 896TRANSOM
MU 883TRANSOM
MU 898MULLION
MU 882MULLION
MU 895MULLION
MU 892MULLION
MU 891MULLION
MU 826ROOF TRANSOM
55
55
43
30°
55
43
45°
MU 82730° RIDGE BAR
MU 82845° RIDGE BAR
Ixx = 728 cm4Iyy = 79 cm4
Ixx = 357 cm4Iyy = 48.8 cm4
Ixx = 207 cm4Iyy = 40.8 cm4
Ixx = 82 cm4Iyy = 30.4 cm4
Ixx = 35 cm4Iyy = 23 cm4
Ixx = 442.8 cm4 Ixx = 333.8 cm4 Ixx = 197.7 cm4 Ixx = 79.8 cm4
Revision : B (--/--/--)
43
68
Ixx = 31.4 cm4Iyy = 51.9 cm4 Iyy = 46.8 cm4 Iyy = 34 cm4 Iyy = 28.4 cm4 Iyy = 21.04 cm4
146
60
153
MU 899-60TRANSOM
Iy= 114.0Ix= 599.0
23
43
Page : 1.1.02
PRESSURE PLATE
8
MU847
52
MU841
99
55
TRANSOM COVER
5571
MU857
1520
55
'H' CAP
MU8500
15
FEATURE CAP
55
TRANSOM COVERMU 805
18
MU 850
20
31
55MU889
MU 800 SERIES MULLION DRAINED SYSTEMCappings and pressure platesScale 1:2
MULLION COVER
BULLET COVER CAP.
20
50
MU 840Fin Cap
55
306
Wing Cap
MU 833
MU 834
MU 835
MU 82430° ridge cap
45° ridge capMU 825
78
23
23
57
40
55
Revision : B (--/--/--)
MU 833
55
250
55
MU 250
230
Box Cap Radius Cap
MU 833
MU 821
50
55
MU 820MULLION / TRANSOM CAP
MU 833
MU 100
MU 100 CAP
137
55
10
Page : 1.1.03
Transom sealing/
Code = CWA001
G 1501EPDM Gridinsulator for24 mm units
CWG 014
CWG 010
(MU 893)end gasket
gaskets and accessoriesScale NTS
MU 800 SERIES MULLION DRAINED SYSTEM
G1505
G1550
T 113Transom Jig
Mullion JigT112Stepped drill bit
CWA 030No. 8 x 19 tamper
Drill bit to suittransom screw T 114
CWA 031
proof transom screw
Revision :D (--/--/--)
Butyl tape 50mm - CWG003100mm - CWG004150mm - CWG005
CWA 02814 x 32 hex head screwwith bonded washer( 6 - 24mm glazing). Seedrawing 1.1.09 & 10
Punch press for curtain wall transoms
Heads for punch toolSmall Medium Large
Transom drainedholes for cleats
Mullion drainedholes for cleats
Mullion drainedholes for transomfixing screws(Oval head)
A B C
Punch press
Punch toolA B C
CWA 02514 x 38 hex head screwwith bonded washer( 28mm glazing). Seedrawing 1.1.09 & 10
CWATB
24 / 28mm glazing -pressure plate gasketCode - CWG001
24 / 28mm glazing -Transom gasket
24 / 28mm glazing -Mullion gasket
Isolator for28mm Units
CWSPOUTDrainagespout
MU899EEnd plate for MU899 capping
MU821ECEnd plate for Radius capping
MU250ECEnd plate for Box capping
MU833EEnd plate for Wing capping
ADAPTER14.5mm GLAZING MU868
Page : 1.1.04
(to suit MU 882)Mullion joint sleeve
MU 848 6mm GLAZING ADAPTER
11.5mm GLAZING ADAPTER
MU 875
MU 836
Ixx = 126.7 cm4
MU 870
(to suit MU 895)Mullion joint sleeve
Ixx = 55 cm4
Mullion joint sleeve(to suit MU 892)
Ixx = cm4
MU 897
suit MU 889Joint sleeve to
MU890
AccessoriesScale NTS
MU 800 SERIES MULLION DRAINED SYSTEM
Mullion joint sleeve(to suit MU 882)
MU 832
Mullion joint sleeve(to suit MU 895)
MU 830
Ixx = 62.4 cm4
Ixx = 143 cm4
Revision : C (--/--/--)
FIXING BRACKET
MU 806
FIXING BRACKET
MU 838
FIXING BRACKET
MU 839
49189
73 735959
90 60
90
145
channel closer tosuit 24mm units
CWAC
24
22
channel closer to suit28mm units
CWAC28
28
26
CWCACill adapter for28mm glazing
MU844 Cleat (Bar length)CWA019 - 57mm cleat (MU883)CWA020 - 72mm cleat (MU896)CWA021 - 101mm cleat (MU894 & MU899)
(For transom spans over 2.5m and/or glassweight is more than 100Kg's, use supportcleats)
MU 820
Standard capping
55
50
MU 800 SERIES MULLION DRAINED SYSTEMCapping assemblyScale NTS
Page : 1.1.08
MU 805
MU 841
MU 833
MU 889
MU 840
MU 8500
MU 835
MU 834
18
43
306
40
70
99Standard capping
'H' Cap
Wing cap
Fin capping
Bullet nose cappingFeature cap
20
15
Rectangular box cap
MU 833 MU 250
250
Revision : B (--/--/--)
Radius cap
MU 833 MU 821
230
MU 850
20Standard capping
MU 100 - Cap
MU 833
Fin Cap
MU 100
55
55
137
Ix= 207cm4
MU 898
Ix= 357cm4MU 882
MU 895
MU 892Ix= 82cm4
Ix= 35cm4MU 891
Ix= 728.28cm4
3563
9912
814
6
18
G 1505
MU 850MU 847Butyl tape
CWA 02814 x 32mm
MU 848
MU 875
Page : 1.1.09
MU 800 SERIES MULLION DRAINED SYSTEMMullion assembly for double / single glazingScale NTS
Revision : B (--/--/--)
34.0
24
38
MU 850MU 847Butyl tape
MU 850MU 847Butyl tape
CWA 02814 x 32mm
MU 850MU 847Butyl tape
CWA 02814 x 32mm
G 1505
G 1505
G 1505
612
CWA 001
CWATB
28
42
24mm Glazing 28mm Glazing
6mm Glazing
12mm Glazing
CWG014
CWG014
CWG014
MU 868
MU 848
MU 875
10mm Glazing
14mm Glazing
18mm Glazing
CWG014
CWG014
CWG014
G 1505
MU 850MU 847Butyl tape
G 1505
MU 850MU 847Butyl tape
G 1505
1815
10
MU 850MU 847Butyl tape
CWA 02514 x 38mm
CWG0143
7
CWA 02514 x 38mm
CWA 02514 x 38mm
CWA 02514 x 38mm
CWA 02514 x 38mm
CWA 02814 x 32mm
G 1505
MU 847Butyl tape
CWA 02814 x 32mm
MU 848
MU 875
Page : 1.1.10
MU 800 SERIES MULLION DRAINED SYSTEMTransom assembly for double / single glazingScale NTS
Revision : C (--/--/--)
24
MU 847Butyl tape
MU 847Butyl tape
CWA 02814 x 32mm
MU 847Butyl tape
CWA 02814 x 32mm
CWG 010
G 1505
G 1505
G 1505
612
CWA 001
CWATB
28
24mm Glazing 28mm Glazing
6mm Glazing
12mm Glazing
153
106
69
135
MU 899
MU 894
MU 896
MU 883
8
25
33
MU 805MU 805
MU 805
MU 805
222222
22
2929
CWG010
MU 868
MU 848
MU 875
10mm Glazing
15mm Glazing
18mm Glazing
MU 847Butyl tape
G 1505
MU 805
22
MU 847Butyl tape
G 1505
MU 805
22
MU 847Butyl tape
G 1505
MU 805
2210
1518
CWG 010
CWG 010
CWG 010
CWG 010
CWG 010
29
CWA 02514 x 38mm
MU 899 & MU899-60
MU 826
3333
33
CWA 02514 x 38mm
CWA 02814 x 32mm
CWA 02514 x 38mm
CWA 02514 x 38mm
CWA 02514 x 38mm
Page : 1.1.12
MU 800 SERIES MULLION DRAINED SYSTEMTypical head detailScale 1:2
Membrane bondedto concrete andglazed into system
Backing rod andsilicone sealant
Insulated panelor alternativelyuse CWAC withpressed angle
Membrane bondedto steel and glazedinto system
Insulated panelor alternativelyuse CWAC withpressed angle
Internal finishto detail
Internal finishto detail
MU 896
MU 896
Revision : B (--/--/--)
MU 805
MU 805
28
28
28
MU 896
Internal finishto detail
Typical head detailScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : B (--/--/--)Page : 1.1.13
KSM 060
KSM 012
Adapter fixed to steel
Curtain wall mullion fixedto structural steel. Steel tosupport weight of curtainwall screen
Adapter fixed tocladding rail
Curtain wall mullion fixedto structural steel. Steel tosupport weight of curtainwall screen
MU 805
MU 805
Page : 1.1.14
MU 800 SERIES MULLION DRAINED SYSTEMTypical cill detailScale 1:2
Continuousmembrane bondedto upstand andclamped to system
Continuous seal
Drainage slot
DPM glazed intosystem
Pressed aluminiumcills
Continuous sealand backing rod
MU 896
MU 896
Revision : C (--/--/--)
MU 805
MU 805
28
28
CWCA
CWCA
Page: 1.1.15
MU 800 SERIES MULLION DRAINED SYSTEMTypical fixing detailScale 1:2
300
min
20
Insulated panel - depthto suit specificationrequirements
MU 896
MU 805
MU 896
Revision : B (--/--/--)
MU 805
28
Bracket fixed to steel with4 no. s/s bolts to suit
Plate welded onto steelchannel by others
Expansion
Load bearingfixing sized tosuit
35
Spandral panel tospecification
Typical fixing detailScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Page : 1.1.16
MU 805
MU 896
MU 896
MU 805
Revision : B (--/--/--)
MUSL 02
MUSL 03
MU 896
MU 805
MUSL 03
MUSL 02
MU 896
60
23
Concealed ventScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : B (--/--/--)Page : 1.1.18
MU 805
MUSL 02
MUSL 03
MU 896
MU 805
MUSL 03
MUSL 02
MU 896
60
23
MU 805
2824
24 28
Typical vent detail - 28mm glazingScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : B (--/--/--)Page : 1.1.19
TS4 906
TS4 015
MU 896
MU 896
CWG010
CWG010
TS4 900
TS4 207
28
28
MU 805
MU 805
28
MU 896
CWG010
TS4 016
MU 805
TS4 900
28
2619
MU 896
CWG010
TS6 209
MU 805
TS6 913
28
28
Section 1.1.20
MU 800 SERIES MULLION DRAINED SYSTEMTypical door head detailScale 1:2
TS4 024
72
68
TS4 014
5511
45
OPTION A
130
OPTION B
126
81
1155
TS4 024
72
24 28
24mm glazingoption
28mm glazingoption
Revision : B (--/--/--)
34 x 20mm box sectionpacker
4mm packer toallow for gasketthickness andcloser channel
MU 896
MU 805
MU 896
MU 805
MU 896
MU 805
MU 896
MU 805
CDM 114
CDM 032
CDM 112
CDM 032
CDM 112
CDM 114
55
TS4 016
24 28
28
2424
Section 1.1.21
MU 800 SERIES MULLION DRAINED SYSTEMTypical jamb detailScale 1:2
80
MU 895 MU 895
MU 895
Revision : B (--/--/--)
MU 850
MU 850
MU 850
KSM 060
KSM 050
2828CWG014
G1505
24
CWG014
CWG014
Section 1.1.22
MU 800 SERIES MULLION DRAINED SYSTEMTypical door jamb detailScale 1:2
TS4 014
5
Revision : B (--/--/--)
24
G1552
G1505
CWG014
55
Rebated door into curtain wall -24mm glazing
Rebated door into curtain wall -28mm glazing
11
TS4 016 TS4 024
MU 895
MU 850
MU 850
MU 895
MU 850
MU 895
CDM 013
28
24
24
TS4 024
28
28
Commercial door into curtain wall- 24mm glazing
Commercial door into curtain wall- 28mm glazing
CWG014
CWG014
CWG014
34 x 20mm boxsection packer
Page : 1.1.23
MU 800 SERIES MULLION DRAINED SYSTEMCorner AssembliesScale NTS
129 55
External corner withMU 882 & MU 892
External corner withMU 892
External corner withMU 892
Revision : B (--/--/--)
MU 892 MU 882MU 892
MU 892
MU 892
MU 892
28
CW
G014
G1505
CW
G014
G1505
28
CW
G01
4
G15
05
Page : 1.1.24
MU 800 SERIES MULLION DRAINED SYSTEMTypical head detail - sloped glazingScale 1:2
Revision : B (--/--/--)
MU 883
Page : 1.1.25
MU 800 SERIES MULLION DRAINED SYSTEMTypical eaves detailScale 1:2
Full perimeterseal
Continuous seal
Revision : B (--/--/--)
MU 857
MU 883
MU 883
MU 805
Page : 1.1.26
Typical jamb detail - Sloped glazingScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : B (--/--/--)
MU 895
CWG014
MU 850
28
False mullion detailScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : B (--/--/--)Page : 1.1.27
MU 896
CWG010
MU 896
01
02
01
02
Transom to beused as falsemullion
MU 805
G1505
MU 805
CWG010
G1505
Ridge detail: 30° slope
MU 827
MU 824Typical ridge detailScale NTS
MU 800 SERIES MULLION DRAINED SYSTEM
Page : 1.1.28
Ridge detail: 25° slope
Ridge detail: 35° slope
30°25°
35°
For for roof slopes between 25 -29° and 31to 35° fully seal joint between ridge bar andrafter with low modulous sealant. Transomend gasket G1550 will not be suitbale forthese slopes.G1550 suitable for 30 & 45° slopes only.
Apply a perimeter seal aroundjoint prior to fixing in position
Apply a perimeter seal aroundjoint prior to fixing in position
Apply a perimeter seal aroundjoint prior to fixing in position
MU 824
MU 827
MU 824
MU 827
Revision : B (--/--/--)
Ridge capping to runcontinuous throughrooflight and rafter cappingto butt against ridge
55°
45°
MU 828
MU 825
MU 800 SERIES MULLION DRAINED SYSTEMTypical ridge detailScale NTS
Page : 1.1.29
40°
For for roof slopes between 40 -44° fullyseal joint between ridge bar and rafter withlow modulous sealant. Transom endgasket G1550 will not be suitbale for theseslopes.G1550 suitable for 30 & 45° slopes only
Apply a perimeter seal aroundjoint prior to fixing in position
Apply a perimeter seal aroundjoint prior to fixing in position
Ridge detail: 45° slope
Ridge detail: 40° slope
MU 828
Revision : B (--/--/--)
Ridge capping to runcontinuous throughrooflight and rafter cappingto butt against ridge
MU 825
Page : 1.1.30
MU 800 SERIES MULLION DRAINED SYSTEMDouble transom ridge detailScale 1:2
Ridge detail:Suitable for all roof slopes
MU 826 MU 826
MU 857
Revision : B (--/--/--)
2mm pressing fitted over capping toprevent water build up in ridge area(Optional)
Page : 1.1.31
Typical cill detail - Sloped glazingScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Continuous seal
MU 826
MU 857
Revision : C (--/--/--)
CWCA
Page : 1.1.32
MU 800 SERIES MULLION DRAINED SYSTEMTypical details - MU899-60Scale NTS
Revision : A (--/--/--)
MU 805
28
28
MU 805
28
MU 805
28
TS6 209
TS6 913
2830
604951
TS4 024
72
TS4 016
28
28
TS4 024 - Open out,Externally beaded door.
100
TS6 209
127
685
54
MU 805
13
1313 12
.560
126
MU899-60 - transom detail
TS6 022 - Open out,Internally beaded door.
TS66 insert .
555555
Typical Inserts - 28mm glazingScale 1:2
MU 800 SERIES MULLION DRAINED SYSTEM
Revision : A (--/--/--)Page : 1.1.33
MU 896
CWG010
TS6 209
MU 805
TS6 913
28
28
MU 896
CWG010
HL 211
MU 805
HL 96328
MU 896
CWG010MU 805
100
685
TS6 022 - Open out,Internally beaded door.
128
57
MU 896
CWG010MU 805
113
2786
100
5545
TS6 908Tilt and turn insert
HL963 / HL 211Slim line insert
TS6 210
TS6 908
TS6 209 / TS6 913Standard insert