apollo panel light-b-1 - kinglumi 16 126lm per watt apollo pan… · apollo . panel light •...
Post on 12-Apr-2018
218 Views
Preview:
TRANSCRIPT
FLICKER
UGR16Visual
comfortModularDesign
126/116lm/W
APOLLO . PANEL LIGHTAPOLLO . PANEL LIGHTNEW PRODUCTS
LED LIGHTING
APOLLO . PANEL LIGHT
• Modular Design: 1 pair of light module with different frames fit all European ceiling grid.• Less inventory and risk, faster time to projects, allow variety of ceiling grid size• Glare free: UGR<16, luminance limits @65°<1000cd/m , EN 12464-1: 2011 compliant• High efficacy: Up to 126lm/W(Pro), or 100lm/W(Standard)• More useful light: over 90% useful lumen in cone 90°(zonal lumen)• Dimming: Non-diming, DALI and 1-10V dimming(only for Pro.)• Class II,SELV, High Power Factor over 0.95• Non-flicker design(only for Pro).• Aluminum passive cooling, TcLED<61°C(Ta=25°C)• Installtion: Recessed/Pendant mounted• Direct replacement for T8- 3x18W/4X18W; T5- 3x14W/4X14W• Up to 65% energy saving, 3 times longer lifespan compared to fluorescent lamps.
Features:
PARAMETERS
Power(W):Heat sink:Lifespan(hrs):CRI:Beam Angle:
28(Pro); 30(Standard)Aluminum50,0008285°x70°
3600(Pro); 3400(Standard)220-240126(Pro); 116(Standard)2x63pcs Epistar SMD 2835-20-40°C
Lumen(lm):Input Voltage(VAC):Efficacy(lm/W):LED ChipsWorking Temp:
Cut-out: To fit all Europe ceiling T grid:600*600 / 625*625、300*1200、600*1200
UGR
16 5years warranty
2
Recessed
Pendent
38
1195
29549
489
620
620
595
595
Installation Dimention(mm)
APOLLO . PANEL LIGHT
LIGHT DISTRIBUTION
Kinglumi Apollo Panel light Fluorescent Modular Flat LED Panel
Philips TBS262 4xTL5-14W 840 HFS M6 40W 600x600 NW LED panel light Eco2K&L Apollo Panel 4000K
105
90
75
60
45
30 3015 150
105300
300
600
900
1200
1500
90
75
60
45
75
60
45
105
90
75
60
45
30 3015 150
105
320
480
640
90
105
90
75
60
45
30 3015 150
105400
400
800
1200
1600
2000
90
75
60
45
Symmetrical light distribution with a batwing.
1.0m 211.00cm2224.8 , 960.3 lx
2.0m 422.00cm556.2 , 240.1 lx
3.0m 632.99cm247.2 , 106.7 lx
5.0m 1054.99cm89.0 , 38.4 lx
Max , Ave Beam angle of C120 plane 84x67
Lux distance CurveAt application: (4H,8H), Reflection (70%,50%,20%)Standard Version: UGR≤14 Pro Version: UGR≤15
UGR table of Pro version 595*595 3600lm
UGR Table
Illumination assessment according UGRRf of Ceiling 70 70 50 50 30 70 70 50 50 30Rf of Wall 50 30 50 30 30 50 30 50 30 30Rf of Floor 20 20 20 20 20 20 20 20 20 20Room dimensions Viewed crosswise Viewed endwiseX Y2H 2H
3H4H6H8H12H
4H 2H3H4H6H8H12H
8H 4H6H8H12H
12H 4H6H8H
Variation with the observer position at spacings:S = 1.0HS = 1.5HS = 2.0H
Standard tables:Uncorrected UGR
10.7310.5510.4610.3810.3110.2410.5110.2910.2310.0910.039.9810.039.889.869.809.989.869.80
11.8511.5311.3711.2111.1010.9911.4111.0410.8710.6610.5610.4710.5610.3110.2310.1010.4710.2310.10
11.1010.9410.8610.8010.7310.6710.9110.7210.6610.5610.5210.4710.5210.3810.3910.3410.4710.3910.34
12.1611.8711.7211.5811.4811.3811.7611.4311.2911.1111.0110.9211.0110.7910.7510.6110.9210.7510.61
12.4712.2212.0911.9811.8911.8012.1311.8511.7411.5611.4911.4311.4911.3011.2511.1311.4311.2511.13
14.9414.7614.6614.5814.5114.4414.6614.4514.3814.2514.1914.1414.1914.0314.0213.9614.1414.0213.96
16.0515.7415.5715.4115.3015.1915.5715.1915.0214.8114.7114.6214.7114.4714.3914.2614.6214.3914.26
15.3015.1415.0615.0014.9314.8715.0614.8714.8214.7214.6714.6314.6714.5414.5514.5014.6314.5514.50
16.3616.0715.9215.7915.6915.5915.9215.5915.4515.2615.1715.0715.1714.9514.9114.7715.0714.9114.77
16.6716.4216.2916.1816.0916.0016.2916.0015.9015.7215.6415.5915.6415.4615.4015.2915.5915.4015.29
2.2/-6.7 4.6/-25.54.1/-21.5 6.4/-29.06.1/-28.6 8.4/-29.5BK0 BK0-4.0 -8.2
UGR calculation is based on CIE Publ. 117 ,S/H = 0.25
APOLLO . PANEL LIGHT
LUMINANCE LIMITS
Luminance Limitting Curveγ(°)
85
75
65
55
456 7 8 9 1000 2 3 4 5 6 7 8 9 10000 2 3
L(cd/m²)4
-2
-3
-4
-6-8 (a/hs)
a b c d e f g h
C0 C45 C90
According to EN12464-2011 part 4.9.2, Light can lower the contrast of the presentation on a DSE. The Table 1 gives the limits of the average luminaire luminance at elevation angles of 65° and above from the downward vertical, radially around the luminaires, for work stations where display screens which are vertical or inclined up to 15° tilt angle are used.
Table 1 — Average luminance limits of luminaires, which can be reflected in flat screens
Screen high state luminance High luminance screen
L> 200 cd·m-2
Medium luminance screen
L ≤ 200 cd·m-2
Case A (positive polarity and normal
requirements concerning colour anddetails of the shown information, as
used in office, education, etc.)
(negative polarity and/or higherrequirements concerning colour anddetails of the shown information, as
used for CAD colour inspection, etc.)
≤3 000 cd·m -2 ≤1 500 cd·m-2
≤1 500 cd·m -2 ≤1 000 cd·m-2
Case B
NOTE Screen high state luminance (see EN ISO 9241-302) describes the maximumluminance of the white part of the screen and this value is available from the manufacturerof the screen.
Glare Table
Glare Quality Service Values Illuminance(lx)
1.15 A 2000 1000 500 <=300
1.5 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.2 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h
luminance limits @65°<1000cd/m
E-mail: sales@kinglumi.com Http: www.kinglumi.comFax: 0086-755-29516759 Tel: 0086-755-29516789 33985808Add: Bldg 3,Nangang Third Industrial Zone,Tangtou,Shiyan Town,Bao’anDistrict,Shenzhen City,China 518108
Professional I Unique I ComfortableLED LIGHTING