Autoclave (Sterilizer) -FeatureAn autoclave is a strong heated container used for chemical reactions and other processes in need of high amounts of pressure and temperature. Sterilization Autoclaves have a variety of uses in the fields of microbiology, medicine, podiatry, tattooing, body piercing, veterinary science, mycology, funeral homes, dentistry, prosthetics fabrications, etc.

Autoclave 140www.samheung21.com

Feature

Leveling caster

Stainless Steel Door sealing gasket

Digital PID ControllerSafety devices

Basket Detail

Catalog No. Type DIMENSION(WxDxH) Weight Material Applicable Model

AC60WB WIRE BASKET 318x265 1 Kg

Stainless Steel

SH-AC-60M

AC80WB WIRE BASKET 368 x 270 1.3 Kg SH-AC-80M

AC100WB WIRE BASKET 418 x 270 1.5 Kg SH-AC-100M

AC128WB WIRE BASKET 468 x 270 3 Kg SH-AC-120M

Uniformity Sheet

Temperature

Reached in 19 Min

Autoclave 141www.samheung21.com

Temp uniformity less than ±1℃at Operation Temp 121℃

Autoclave (Sterilizer):

Model SH-AC-60M SH-AC-80MTemp Range Max 130℃ (266℉)Using Press 0.1177 to 0.1274 MPa (1.2 to 1.3 kg/cm2)

Time Controller Microprocessor Digital PID ControllerSterling Time 00.00 to 99HR 59MIN (MIN SEC) selectable

Pressure Gauge Mechanical type 0 to 0.3 MPaSensor PT-100Capa 60 L 80 L

Dimension Internal350Φx630H(mm) 400Φx650H(mm)

13.78Φx24.80H(inch) 15.75Φx25.59H(inch)

Dimension External(W D H )

550x680x1060(mm) 600x730x1060(mm)

21.65x26.77x41.93(inch) 23.62x28.74x41.73(inch)

Net weight 74 Kg 100 KgMaterial Internal Stainless SteelMaterial External Steel Plate with Powder Heating Coated

Heater 3 KW

Electrical Requirements120V ,50/60Hz, 1Φ 25.0 A

Cat. No. AC60M120 AC80M120

Electrical Requirements230V ,50/60Hz, 1Φ 13.0 A

Cat. No. AC60M230 AC80M230

Accessory Safety Device

Wire basket x 2EA -p.141 Automatic reset function incoming power cutBuzzer on When Set Time ArrivedElectric leakage circuit breakerOver temperature protection deviceDual Over pressure protection device

Autoclave 142www.samheung21.com

SH-AC-60M SH-AC-80M

Model SH-AC-60M SH-AC-80M

Dimension Internal350Φx630H(mm) 400Φx650H(mm)

13.78Φx24.80H(inch) 15.75Φx25.59H(inch)

Dimension External(W D H )

550x680x1060(mm) 600x730x1060(mm)

21.65x26.77x41.93(inch) 23.62x28.74x41.73(inch)

Illustrations

Autoclave 143www.samheung21.com

Autoclave (Sterilizer):

Model SH-AC-100M SH-AC-128M

Temp Range Max 130℃ (266℉)

Using Press 0.1177 to 0.1274 MPa (1.2 to 1.3 kg/cm2)

Time Controller Microprocessor Digital PID Controller

Sterling Time 00.00 to 99HR 59MIN (MIN SEC) selectable

Pressure Gauge Mechanical type 0 to 0.3 MPa

Sensor PT-100

Capa 100 L 128 L

Dimension Internal 450Φx650H(mm) 500Φx650H(mm)17.72Φx25.59H(inch) 19.69Φx25.59H(inch)

Dimension External(W D H )

650x780x1080(mm) 700x830x1350(mm)25.59x30.71x42.52(inch) 27.56x32.68x53.15(inch)

Net weight 120 Kg 132.9 KgMaterial Internal Stainless SteelMaterial External Steel Plate with Powder Heating Coated

Heater 5 KWElectrical Requirements

120V ,50/60Hz, 1Φ 41.7 A

Cat. No. AC100M120 AC128M120

Electrical Requirements230V ,50/60Hz, 1Φ 22.7 A

Cat. No. AC100M230 AC128M230

Accessory Safety Device

Automatic reset function incoming power cutBuzzer on When Set Time ArrivedElectric leakage circuit breakerOver temperature protection deviceDual Over pressure protection device

Autoclave 144www.samheung21.com

Wire basket x 2EA -p.141

SH-FU3.5MGU SH-FU6.4MGUSH-AC-100M SH-AC-128M

Model SH-AC-100M SH-AC-128M

Dimension Internal450Φx650H(mm) 500Φx650H(mm)

17.72Φx25.59H(inch) 19.69Φx25.59H(inch)

Dimension External(W D H )

650x780x1080(mm) 700x830x1350(mm)

25.59x30.71x42.52(inch) 27.56x32.68x53.15(inch)

Illustrations

Steam Indicator Tape

Model No. Wide(mm)(inch) Length

SH-IT-1 12.7 mm(1/2 )

55 metersSH-IT-2 19 mm(3/4 )

SH-IT-3 25.4 mm(11 )

Autoclave 145www.samheung21.com