BRIGHT GREENfrom new to renew

SUSTAINABILITY

"Development that meets the needs of the present without compromising the ability of

future generations to meet their own needs ."

MAINE’S ENERGY PROBLEM: OUR FRIEND THE OIL BOILER

NATIONAL SECURITY

MAINE’S ENERGY PROBLEM: OUR FRIEND THE OIL BOILER

NATIONAL SECURITY

CLIMATE CHANGE

MAINE’S ENERGY PROBLEM: OUR FRIEND THE OIL BOILER

NATIONAL SECURITY

CLIMATE CHANGE

COMFORT

MAINE’S ENERGY PROBLEM: OUR FRIEND THE OIL BOILER

HOW DO WE FIX OUR ENERGY PROBLEM?

FALMOUTH FLYER

LEED-H GOLD HERS 53

METRO GREEN

LEED-H PLATINUM HERS 51

$178 to heat / year

DOUBLE STUD WALLS ON THE

DIME

LEED-H GOLD HERS 33

DOUBLE STUD WALL

PACKED WITH CELLULOSE INSULATION (R-40)

BLOWER DOOR TEST

HEAT RECOVERY VENTILATOR

85% EFFICIENT, CONSTANT SUPPLY OF FRESH AND HEALTHY AIR

TRIPLE GLAZED WINDOWS

R-6 WINDOW

(TYPICAL NEW CONSTRUCTION IS R-3)

LEED-H PLATINUM HERS 22

WHAT ABOUT THE REST OF THE

HOUSES?

THERE SURE ARE A LOT OF THESE OUT THERE

DEERING GRAND

MUNJOY WHEELHOUSE

YOUR NEW TOOLS

SUSTAINABILITY#1: ENERGY

#2: LOCATION#3: COMFORT & HEALTH

#4: MATERIALS

THE NUMBERS

AVERAGE MAINE HOUSE: 1,200 GALLONS OF OIL

GALLON OF OIL: 140,000 BTU

AVERAGE MAINE HOUSE: 168,000,000 BTU / YR

AVERAGE MAINE HOUSE: 80,000 BTU / SF / YR

THE NUMBERS

AVERAGE MAINE HOUSE: 1,200 GALLONS OF OIL

GALLON OF OIL: 140,000 BTU

AVERAGE MAINE HOUSE: 168,000,000 BTU / YR

AVERAGE MAINE HOUSE: 80,000 BTU / SF / YR

ENERGY STAR: 50,000 BTU / SF / YR

LOW ENERGY: 20,000 BTU / SF / YR

DOUBLE STUD WALL: 12,500 BTU / SF / YR

THE NUMBERS

AVERAGE MAINE HOUSE: 1,200 GALLONS OF OIL

GALLON OF OIL: 140,000 BTU

AVERAGE MAINE HOUSE: 168,000,000 BTU / YR

AVERAGE MAINE HOUSE: 80,000 BTU / SF / YR

SOLAR HOT WATER: $35 - $50 / MONTH

250 GALLONS OF OIL / YEAR: $500 - $750 / YEAR

SOLAR HOT WATER + NEW BOILER: 50% REDUCTION

BLOWER DOOR TEST

AVERAGE OLD MAINE HOUSECFM50 3,500

GOOD TIGHT HOUSECFM50 1,000

BRIGHTBUILT BARNCFM50 98

AVERAGE OLD MAINE HOUSEHERS 130

IECC 2004 CODE HOUSEHERS 100

ENERGY STARHERS 85

NET-ZEROHERS 0

FALMOUTH FLYERHERS 53

METRO GREENHERS 51

DOUBLE STUD WALLSHERS 36

BRIGHTBUILT BARNHERS 22

platinum, gold, silver & certified

MADELINE REFAB

THIS IS MY NEW HOUSE...

BRING ON THE DEMO!

R-10 under the slab

R-20 basement walls

R-40 sip screwed on outside walls

R-60 attic insulation

TRIPLE GLAZED WINDOWS

R-8 GERMAN WINDOWS

(TYPICAL NEW CONSTRUCTION IS R-3)

HEAT RECOVERY VENTILATOR

85% EFFICIENT, CONSTANT SUPPLY OF FRESH AND HEALTHY AIR

BUT ARCHITECTS CAN’T HELP MESSING WITH THINGS...