Developments in micro e e op e ts c osampling solutions

CPAC 2009 Michel JOSSEAU March 25 ,2009

EIF FiltresEIF Filtres

French compagny specialized since 35 years in

filtration equipments and sampling treatments.

Micro sampling for process analysis

Global Solutions with Astute 3D design

CPAC 2009 March 25 ,2009

Nessi sampling & Analytical devices on the process

WHY ?

CPAC 2009 March 25 ,2009

Increase the quality of the measure

Decrease the response timeDecrease the response time

Cut the costs of built

Eliminate the effluents

CPAC 2009 March 25 ,2009

SHELTER ANALYZERANALYZER

s Pi

pe $PumpUtilities

$

Proc

ess

Fast loop(heated)

$ $

Disposal

$$

CPAC 2009 March 25 ,2009

Nessi sampling & Analytical devices on the process

HOW …

CPAC 2009 March 25 ,2009

3 Innovative solutions

Astute with extractive probep

Astute with gas treatment column

Astute with CCIMS isolating valve

CPAC 2009 March 25 ,2009

Astute with extractive probe

CPAC 2009 March 25 ,2009

Astute 3D sampling assySampling + Sensors& micro-analyzers

Extractive sonde

PROCESS

CPAC 2009 March 25 ,2009

Sampling + Sensors& micro-analyzers

CPAC 2009 March 25 ,2009

Retraction CavityFor Short Probes

E lEqualPressure

Sample entersthe 9/16” dia tubing

Sample exits the ¼” dia tubing

CPAC 2009 March 25 ,2009

Sample to

Probe Magnetic Indicator

Sample Returnp

ASTUTE SCM

Probe Crank HandleProbe Lock

Indicator

¾” NPT¾ NPT

CPAC 2009 March 25 ,2009

Delta P

Sample entersthe 9/16” dia tubing

Sample exits the ¼” dia tubingSample exits the ¼ dia tubing

CPAC 2009 March 25 ,2009

Option:Option:Retraction Cavity ExtensionFor Long Probes

Crank Handle

CPAC 2009 March 25 ,2009

CPAC 2009 March 25,2009

Micro GCH2 sensor

Micro GC

Fine conditionning &Control devices

SAMPLE GASFine

T t t & SAMPLE GASTreatment &sensors

CPAC 2009 March 25,2009

Benefits :Benefits :

Installation and maintenance withoutInstallation and maintenance withoutdepressurizing

Sample circulation loop integrated

No external drain needed

Easy to isolateEasy to isolate

CPAC 2009 March 25 ,2009

Applications :Applications :

Natural gas

Gas chromatographs

BTU

H2S

MoistureMoisture

CPAC 2009 March 25 ,2009

Astute with gas treatment columnAstute with gas treatment column

CPAC 2009 March 25 ,2009

Sampling + Sensors& micro-analyzers

GAS TREATMENTCOLUMN

PROCESS

CPAC 2009 March 25 ,2009

PROCESS

Demister

Vortex tubecooler

Heat exchanger

Temperature sensor

Heat exchanger

UPSTREAM SAMPLE GAS

C DOWNSTREAM CONDENSATE & PARTICULES

Coarsetreatment

CPAC 2009 March 25 ,2009

Moisture sensorOxygen sensor

Fine conditionning &Control devices

FineT t t & SAMPLE GASTreatment &

sensors

CPAC 2009 March 25,2009

Benefits :Benefits :

Complete sampling treatment packageComplete sampling treatment package

Optimum protection for sensors & analyzers

Condensates & particules stay in the process

CPAC 2009 March 25 ,2009

Applications :Applications :

Gas analysis

Oxygen in reactor gas overhead

Fermentors

CPAC 2009 March 25 ,2009

Astute with CCIMS isolating valveg

CPAC 2009 March 25,2009

Sampling + Sensors& micro-analyzers

CCIMS CLAMPS

ISOLATING VALVES

CCIMS System

ISOLATING VALVES

PROCESS

CPAC 2009 March 25 ,2009

DiaphragmPit t t b

Venturi

CPAC 2009 March 25 ,2009

Pitot tube

Benefits :Benefits :

Different kind of vacuum devices availableClamped system for maintenance

Sample circulation loop integratedSample circulation loop integrated

No external drain needed

Fire safety valvesFire safety valves

CPAC 2009 March 25 ,2009

Applications :Applications :

Gas analysisGas analysis

Moisture measurement

CPAC 2009 March 25 ,2009

Micro viscosity-density sensor

Moisture

ipe

sensor

roce

ss P

i

H2 sensorOxygenSensor

Pro

Mi GCRolsi valve

Micro GC

CPAC 2009 March 25 ,2009

Thank you for your attention y y