Developments in micro e e op e ts c osampling solutions
CPAC 2009 Michel JOSSEAU March 25 ,2009
EIF FiltresEIF Filtres
French compagny specialized since 35 years in
filtration equipments and sampling treatments.
Micro sampling for process analysis
Global Solutions with Astute 3D design
CPAC 2009 March 25 ,2009
Nessi sampling & Analytical devices on the process
WHY ?
CPAC 2009 March 25 ,2009
Increase the quality of the measure
Decrease the response timeDecrease the response time
Cut the costs of built
Eliminate the effluents
CPAC 2009 March 25 ,2009
SHELTER ANALYZERANALYZER
s Pi
pe $PumpUtilities
$
Proc
ess
Fast loop(heated)
$ $
Disposal
$$
CPAC 2009 March 25 ,2009
Nessi sampling & Analytical devices on the process
HOW …
CPAC 2009 March 25 ,2009
3 Innovative solutions
Astute with extractive probep
Astute with gas treatment column
Astute with CCIMS isolating valve
CPAC 2009 March 25 ,2009
Astute with extractive probe
CPAC 2009 March 25 ,2009
Astute 3D sampling assySampling + Sensors& micro-analyzers
Extractive sonde
PROCESS
CPAC 2009 March 25 ,2009
Sampling + Sensors& micro-analyzers
CPAC 2009 March 25 ,2009
Retraction CavityFor Short Probes
E lEqualPressure
Sample entersthe 9/16” dia tubing
Sample exits the ¼” dia tubing
CPAC 2009 March 25 ,2009
Sample to
Probe Magnetic Indicator
Sample Returnp
ASTUTE SCM
Probe Crank HandleProbe Lock
Indicator
¾” NPT¾ NPT
CPAC 2009 March 25 ,2009
Delta P
Sample entersthe 9/16” dia tubing
Sample exits the ¼” dia tubingSample exits the ¼ dia tubing
CPAC 2009 March 25 ,2009
Option:Option:Retraction Cavity ExtensionFor Long Probes
Crank Handle
CPAC 2009 March 25 ,2009
CPAC 2009 March 25,2009
Micro GCH2 sensor
Micro GC
Fine conditionning &Control devices
SAMPLE GASFine
T t t & SAMPLE GASTreatment &sensors
CPAC 2009 March 25,2009
Benefits :Benefits :
Installation and maintenance withoutInstallation and maintenance withoutdepressurizing
Sample circulation loop integrated
No external drain needed
Easy to isolateEasy to isolate
CPAC 2009 March 25 ,2009
Applications :Applications :
Natural gas
Gas chromatographs
BTU
H2S
MoistureMoisture
CPAC 2009 March 25 ,2009
Astute with gas treatment columnAstute with gas treatment column
CPAC 2009 March 25 ,2009
Sampling + Sensors& micro-analyzers
GAS TREATMENTCOLUMN
PROCESS
CPAC 2009 March 25 ,2009
PROCESS
Demister
Vortex tubecooler
Heat exchanger
Temperature sensor
Heat exchanger
UPSTREAM SAMPLE GAS
C DOWNSTREAM CONDENSATE & PARTICULES
Coarsetreatment
CPAC 2009 March 25 ,2009
Moisture sensorOxygen sensor
Fine conditionning &Control devices
FineT t t & SAMPLE GASTreatment &
sensors
CPAC 2009 March 25,2009
Benefits :Benefits :
Complete sampling treatment packageComplete sampling treatment package
Optimum protection for sensors & analyzers
Condensates & particules stay in the process
CPAC 2009 March 25 ,2009
Applications :Applications :
Gas analysis
Oxygen in reactor gas overhead
Fermentors
CPAC 2009 March 25 ,2009
Astute with CCIMS isolating valveg
CPAC 2009 March 25,2009
Sampling + Sensors& micro-analyzers
CCIMS CLAMPS
ISOLATING VALVES
CCIMS System
ISOLATING VALVES
PROCESS
CPAC 2009 March 25 ,2009
DiaphragmPit t t b
Venturi
CPAC 2009 March 25 ,2009
Pitot tube
Benefits :Benefits :
Different kind of vacuum devices availableClamped system for maintenance
Sample circulation loop integratedSample circulation loop integrated
No external drain needed
Fire safety valvesFire safety valves
CPAC 2009 March 25 ,2009
Applications :Applications :
Gas analysisGas analysis
Moisture measurement
CPAC 2009 March 25 ,2009
Micro viscosity-density sensor
Moisture
ipe
sensor
roce
ss P
i
H2 sensorOxygenSensor
Pro
Mi GCRolsi valve
Micro GC
CPAC 2009 March 25 ,2009
Thank you for your attention y y