dse 4510/20 - imsab · load power monitoring, the ... petrol engines all in one variant. with a...

Post on 30-Apr-2018

236 Views

Category:

Documents

2 Downloads

Preview:

Click to see full reader

TRANSCRIPT

PC

The DSE4510 Auto Start ControlModule and the DSE4520 AutoMains (Utility) Failure ControlModule are suitable for a widevariety of single gen-setapplications.

Whilst maintaining functionsincluded within higher endcontrollers, such as generator orload power monitoring, theDSE45xx range of especiallycompact controllers provide theuser with the ultimate size tofeature ratio.

Monitoring engine speed, oilpressure, coolant temperature,frequency, voltage, current, powerand fuel level, the modules will givecomprehensive engine andalternator protection. This will beindicated on the largest back-litLCD icon display in its class via anarray of warning, electrical trip andshutdown alarms.

Electronic J1939 (CAN) and non-electronic (alternator sensing)engine support for diesel, gas andpetrol engines all in one variant.With a number of flexible inputs,outputs and protections, themodules can be easily adapted tosuit a wide range of applicationsincluding lighting towers with theadded option for staged loadingoutputs.

Through USB Communication bothmodules can be easily configuredusing the DSE Configuration SuitePC Software or can be fullyconfigured through the module'sfascia.

All DSE products are supported bythe DSE global tech nical supportteam which gives our customersand end users access to 24 hoursystem help and advice.

DSE4510/20AUTO START AND AUTO MAINS FAILURECONTROL MODULES

®

4

ISSUE 1

USBPORT

DC OUTPUT(2 for DSE4510)

CONFIGURABLEINPUTS

DC POWER SUPPLY

11 1ph2ph3ph

1ph2ph3phN

COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

7

OTHER

DSE4510/20

MAINS (UTILITY)SENSING(DSE4520)

DC OUTPUT1 OF 4

GENERATOR /LOAD CURRENT

DC OUTPUT1 OF 4

GENERATORSENSING

CHARGEALTERNATOR

FUEL ANDCRANK OUTPUTS

ELECTRONICENGINE CAN

ANALOGUE SENDERS

FEATURES

ENVIRONMENTAL TESTING STANDARDS

ELECTRO-MAGNETIC COMPATIBILITYBS EN 61000-6-2EMC Generic Immunity Standard for the Industrial EnvironmentBS EN 61000-6-4EMC Generic Emission Standard for the Industrial Environment

ELECTRICAL SAFETYBS EN 60950Safety of Information Technology Equipment, including Electrical Business Equipment

TEMPERATUREBS EN 60068-2-1Ab/Ae Cold Test -30 oCBS EN 60068-2-2Bb/Be Dry Heat +70 oC

VIBRATIONBS EN 60068-2-6Ten sweeps in each of three major axes5 Hz to 8 Hz @ +/-7.5 mm, 8 Hz to 500 Hz @ 2 gn

HUMIDITYBS EN 60068-2-30Db Damp Heat Cyclic 20/55 oC@ 95% RH 48 HoursBS EN 60068-2-78Cab Damp Heat Static 40 oC@ 93% RH 48 Hours

SHOCKBS EN 60068-2-27Three shocks in each of three major axes15 gn in 11 mS

DEGREES OF PROTECTIONPROVIDED BY ENCLOSURESBS EN 60529IP65 - Front of module when installed into thecontrol panel with the optional sealing gasket.

34

+ +VOLTS

DSEGenset

+

+

1ph2ph3phN

VOLTS D +W/L

DEUTZISUZUPERKINSCATERPILLARMTUVOLVOCUMMINSSCANIA

DEEP SEA ELECTRONICS PLC UKHighfield House, Hunmanby Industrial Estate, Hunmanby YO14 0PHTELEPHONE +44 (0) 1723 890099 FACSIMILE +44 (0) 1723 893303EMAIL sales@deepseaplc.com WEBSITE www.deepseaplc.com

DEEP SEA ELECTRONICS INC USA3230 Williams Avenue, Rockford, IL 61101-2668 USATELEPHONE +1 (815) 316 8706 FACSIMILE +1 (815) 316 8708EMAIL sales@deepseausa.com WEBSITE www.deepseausa.com

055-132/09/12 (1)

KEY BENEFITS• Ultimate size to feature ratio • Automatically transfers between

mains (utility) and generator(DSE4520 only)

• Hours counter provides accurateinformation for monitoring andmaintenance periods

• User-friendly set-up and buttonlayout for ease of use

• Multiple parameters aremonitored simultaneously whichare clearly displayed on thelargest back-lit icon display inits class

• The module can be configuredto suit a wide range ofapplications

• Compatible with a wide rangeof CAN engines, including tier 4engine support

• Uses DSE Configuration SuitePC Software for simplifiedconfiguration

• Licence-free PC software• IP65 rating (with optional

gasket) offers increasedresistance to water ingress

KEY FEATURES• Largest back-lit icon display in

its class• Fully configurable via the fascia

or PC using USBcommunication

• Extremely efficient power savemode

• 3 phase generator sensing• 3 phase mains (utility) sensing

(DSE4520 only) • Generator/load power

monitoring (kW, kV A, kV Ar, pf)• Generator/load current

monitoring and protection• Fuel and crank outputs

(configurable when using CAN)• 4 configurable DC outputs (2 for

DSE4510)

• 3 configurable analogue/digitalinputs

• 4 configurable digital inputs• Configurable staged loading

outputs• CAN and alternator speed

sensing in one variant• 3 engine maintainance alarms• Engine speed protection• Engine hours counter• Engine pre-heat• Engine run-time scheduler• Battery voltage monitoring• Start on low battery voltage• Configurable remote start input• 1 alternative configuration• Comprehensive warning,

electrical trip or shutdownprotection upon fault condition

• LCD alarm indication• Event log (15)

®

RELATED MATERIALSTITLE PART NO’SDSE4510/20 Installation Instructions 053-145DSE4510/20 Operator Manual 057-171DSE4510/20 Configuration Suite PC Manual 057-172

Registered in England & Wales No.01319649VAT No.316923457

Deep Sea Electronics Plc maintains a policy of continuous development and reserves the right to changethe details shown on this data sheet without prior notice. The contents are intended for guidance only.

SPECIFICATION

DC SUPPLYCONTINUOUS VOLTAGE RATING8 V to 35 V Continuous

CRANKING DROPOUTSAble to survive 0 V for 50 mS, providing supply was at least 10 V before dropout and supply recovers to 5 V. This is achieved without the need for internal batteries.LEDs and backlight will not be maintained during cranking.

MAXIMUM OPERATING CURRENT85 mA at 12 V, 96 mA at 24 V

MAXIMUM STANDBY CURRENT51 mA at 12 V, 47 mA at 24 V

MAXIMUM SLEEP CURRENT35 mA at 12 V, 32 mA at 24 V

MAXIMUM DEEP SLEEP CURRENT<10 uA at 12 V, <10 uA at 24 V

MAINS (UTILITY) DSE4520 ONLYVOLTAGE RANGE15 V to 415 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

OUTPUTSOUTPUT A (FUEL)5 A DC at supply voltage

OUTPUT B (START)5 A DC at supply voltage

AUXILIARY OUTPUTS C & D2 A DC at supply voltage

AUXILIARY OUTPUTS E & F DSE45202 A DC at supply voltage GENERATORVOLTAGE RANGE 15 V to 415 V AC (L-N)

FREQUENCY RANGE3.5 Hz to 75 Hz

DIMENSIONSOVERALL140 mm x 113 mm x 43 mm5.5’’ x 4.4” x 1.7”

PANEL CUT-OUT118 mm x 92 mm4.6’’ x 3.6”

MAXIMUM PANEL THICKNESS8 mm0.3”

OPTIONAL PARTS

PART PART NUMBERIP65 Gasket 020-282

DSEGenset

DSE4510/20AUTO START AND AUTO MAINS FAILURECONTROL MODULES

FEATURES

DSE4510

DSE4520