ROLLING STEEL FIRE DOORSINSULATEDSTEELFIREDOORSCUTYOURTOTALCOST
The Wayne-Dalton FireStar 700C Insulated Rolling Steel Fire Door is the innovative solution to safety and fire protection while maintaining thermal integrity.
The FireStar 700C door features fire-resistant insulation, making it the ideal choice for exterior openings that require fire doors. Of course, the 700C offers all the features that make FireStar the most innovative fire door in the industry, including the ability to drop-test and reset the door by anyone without a service call.
FireStar doors also feature forward-thinking designs that outperform other fire doors with their reliable, long-lasting performance with smooth, quiet operation.
F I R E S T A R®
•SIZESUPTO24’WIDE AND24’HIGH (UP TO 324 SQUARE FEET)•EASYTOTEST•NON-TENSIONRELEASE•FLOORRESETTABLE•R-VALUE=5.0•UL/FMRATED•CONFORMSTONFPA STANDARD80 (NATIONAL FIRE PROTECTION ASSOCIATION)
700C
FIRESTAR® 700C SERIES
FireStar700Crollingsteel firedoorsareaninnovativesolution for safety and fireprotection, ideal foruse inopeningswith thermal requirements.Critical elementsnecessary in the reliable function of fire doors areincorporated as standard features with FireStar’srevolutionary design. Smooth slats filled with mineralwoolinsulationprovideadoorR-Valueof5.0.
SafetyThe FireStar 700C door can be drop tested easilyand reset in seconds; no tools or service techniciansrequired. These tests can be done in addition to therequired annual inspection by a trained technician. Byself-testingthroughouttheyear,youcanbeevenmoreconfidentthatthedoorwillfunctionsafelyintheeventoffire.
Thedrop-outmechanismisdesignedtoeliminatedowntime during drop testing while the viscous governortechnologyresultsinsmoother,quieterdooroperation.
ReliabilityFireStar’s revolutionary design uses apatent-pending planetary gear on the drop-outmechanism ensuring years of reliable serviceand drop-out performance. Factory tested andapproved for a minimum of 20,000 cycles, theFireStar door can be used and/or tested on aregularbasis.
FireStarfiredoorshavebeentestedandapprovedtomeet the requirementsofwell known agen-cies, such as Underwriters Laboratories andFactoryMutual,andconformtoNFPAStandard80.
SimplicityWayne-Dalton incorporates one standard-ized component design for all FireStar doorsregardless of size, and utilizes fewer parts thanothermodels.Thishelps toensuremoreaccu-rate installations and reduces the possibility ofpotentialservicecallsinthefuture.
Asanaddedbenefit,eliminatingoneofthefusiblelinkcableshelpsthedoorandsurroundingarealook cleaner and less cluttered. It also reducestheriskofcableinterferencewithothernearbyfixtures.
ROLLING STEEL FIRE DOORS
Features
www.wayne-dalton.com/commercial
700C SERIES700C
Test Device — FireStar700Cinsulateddoorsfeatureaneasy-to-usereleasehandle.
• Easytestingandfloorresattable• SmokeTite®ULlabeledsmokecontrol &draftpackage• STC=22• Innovativeplanetarygeardesignapprovedand testedforaminimumof20,000cycles• R-Value=5.0• Preassembleddrop-outmechanism• Viscousgovernortechnology• Singlefusiblelinkcablerouting• Standardizedcomponentdesignforalldoorsizes• Chainhoist,motororcrankoperation• Availablewithleft-handorright-handoperation• UL/FMapproved
•RevolutionaryFireDoorcontroldevice utilizingaplanetarygeararrangementto disconnecttheoperatoranddropthe doorintheeventofafire.•Easilydroptestandresetafiredoor withoutresettingspringtensionand reroutingcables.
FireStar Door Control DevicesChain hoist and motor operation Crank operation
Patent pending.
•RevolutionaryFireDoorcontroldevice utilizingclutchplatesandunique counterbalancetechnologytodrop thedoorintheeventofafire.•Easilydroptestandresetafiredoor withoutresettingspringtensionand reroutingcables.
1/4"+GDOPENING WIDTH "A"1/4"+GD
1/4"+GDOPENING WIDTH "A"1/4"+GD
ANGLE GUIDES - FACE MOUNTED TO MASONRY
ANGLE GUIDES - FACE MOUNTED TO STEEL
ANGLE GUIDES - MOUNTED BETWEEN JAMBS
OPENING WIDTH "A"
CLEAR OPENING
JAMBJAMB
L RGD GD
COMMON GUIDE MOUNTING OPTIONS
30"
D
Y
X
17"
OPE
NIN
G H
EIG
HT
"F"
B
UNITPOWER
2"
Y
POWERUNIT
2"
17"
X
30"
D B
LEFT GUIDESIDEROOM
LINTEL
WHEELADJUSTING HOOD
RIGHT GUIDESIDEROOM
HOIST
UNITPOWER
EMERGENCY
OPENING WIDTH A6" BRACKETSIDEROOM
10" BRACKETSIDEROOM
2"
2
X
Y
D B
13"
D
Y
X
13"
HAND CHAIN
RIGHT SIDEROOMLEFT SIDEROOM
LINTEL
WHEELADJUSTING
HOOD
OPENING WIDTH A
SIDE ELEVATION (UNDER LINTEL) SIDE ELEVATIONFRONT ELEVATION
SIDE ELEVATION (UNDER LINTEL)FRONT ELEVATION SIDE ELEVATION
CHAIN HOIST OPERATION
MOTOR OPERATION
ROLLING STEEL FIRE DOORS
700C SERIES
ADJUSTINGWHEEL
HOOD
LINTEL
HAND CHAIN
SIDE ELEVATION (UNDER LINTEL) SIDE ELEVATIONFRONT ELEVATION
CRANK OPERATION
1/4"+GDOPENING WIDTH "A"1/4"+GD
1/4"+GDOPENING WIDTH "A"1/4"+GD
ANGLE GUIDES - FACE MOUNTED TO MASONRY
ANGLE GUIDES - FACE MOUNTED TO STEEL
ANGLE GUIDES - MOUNTED BETWEEN JAMBS
OPENING WIDTH "A"
CLEAR OPENING
JAMBJAMB
L RGD GD
COMMON GUIDE MOUNTING OPTIONS
30"
D
Y
X
17"
OPE
NIN
G H
EIG
HT
"F"
B
UNITPOWER
2"
Y
POWERUNIT
2"
17"
X
30"
D B
LEFT GUIDESIDEROOM
LINTEL
WHEELADJUSTING HOOD
RIGHT GUIDESIDEROOM
HOIST
UNITPOWER
EMERGENCY
OPENING WIDTH A6" BRACKETSIDEROOM
10" BRACKETSIDEROOM
2"
2
X
Y
D B
13"
D
Y
X
13"
HAND CHAIN
RIGHT SIDEROOMLEFT SIDEROOM
LINTEL
WHEELADJUSTING
HOOD
OPENING WIDTH A
SIDE ELEVATION (UNDER LINTEL) SIDE ELEVATIONFRONT ELEVATION
SIDE ELEVATION (UNDER LINTEL)FRONT ELEVATION SIDE ELEVATION
CHAIN HOIST OPERATION
MOTOR OPERATION
ROLLING STEEL FIRE DOORS
ACCESSORIES
NOTE:Dimensionsareforgeneralreferenceonlyandnotforconstructionpurposes.
Slat ProfileStandard Weatherseal Applications
To close spacebetweencurtainandguidesatjambs,flexiblestriponguidescontactsflatsurfaceofcurtain.
Bottom bar with weatherseal To reduce air infiltrationattopofdoor,hoodbaffleattachedtohoodextendsfullwidthofdoor.Optionallintelweatherstrippingwillfurtherreduceairpassagewhenattachedtotheheader.
WayneGuard Release Systems Smoke DetectorsHorns and Strobes
700CSeriesDoor
GD WIDTH
27⁄8”TO13’6”WIDTH
213⁄16”TO20’0”WIDTH
31⁄4”TO24’0”WIDTH
1/4"+GDOPENING WIDTH "A"1/4"+GD
1/4"+GDOPENING WIDTH "A"1/4"+GD
ANGLE GUIDES - FACE MOUNTED TO MASONRY
ANGLE GUIDES - FACE MOUNTED TO STEEL
ANGLE GUIDES - MOUNTED BETWEEN JAMBS
OPENING WIDTH "A"
CLEAR OPENING
JAMBJAMB
L RGD GD
COMMON GUIDE MOUNTING OPTIONS
NOTE:Dimensionsareforgeneralreferenceonlyandnotforconstructionpurposes.
Width A
HEIGHT B (OPENING HEIGHT)
9’0” TO 14’0” TO 18’0” TO 24’0”
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
X Y R L X Y R L X Y R L X Y R L
3” SLAT
TO 24’0” 16–1⁄2” 15” 10” 6” 20” 19” 10” 6” 22” 21” 10” 6” 24” 23” 10” 6”
Width A
HEIGHT B (OPENING HEIGHT)
9’0” TO 14’0” TO 18’0” TO 24’0”
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
BRACKET SIZE SIDE ROOM
X Y R L X Y R L X Y R L X Y R L
3” SLAT
TO 24’0” 16–1⁄2” 15” 7-1⁄16” 9-1⁄16” 18–1⁄2” 17” 7-1⁄16” 9-1⁄16” 22” 21” 7-1⁄16” 9-1⁄16” 24” 23” 7-1⁄16” 9-1⁄16”
20’0” TO24’0” 16–1⁄2” 15” 7-1⁄2” 10-1⁄4” 18–1⁄2” 17” 7-1⁄2” 10-1⁄4” 22” 21” 7-1⁄2” 10-1⁄4” 25” 25” 7-1⁄2” 10-1⁄4”
TheDoor&AccessSystemsManufacturersAssociation(DASMA)supportsperiodicinspectionofFireDoorassembliesasstatedintheNationalFireProtectionAssociationStandard80.
ROLLING STEEL FIRE DOORS
700C SERIES
700 Series (Face Mounted - Chain Hoist/Motor/Crank)
700 Series (Between Jambs Mounted - Under Lintel Chain Hoist/Motor/Crank)
ROLLING STEEL FIRE DOORS
PART I – GENERAL 1.01 Work Included A. TheopeningwillbeequippedwithWayne-Dalton 700CSeriesrollingdoors.
1.02 Related Work A. Openingpreparation,miscellaneousorstructural metalwork,accesspanels,finishorfieldpainting, fieldelectricalwiring,wire,conduit,fuses,and disconnectswitchesareintheScopeofWorkof otherdivisionsortrades.
1.03 Reference Standards A. ANSI/DASMA 204–AmericanNational StandardsInstituteSpecificationsforratedfirerolling doorspublishedbyDoor&AccessSystems ManufacturersAssociationInternational. B. ASTM A123–Zinc[hot-dippedgalvanized] coatingsonironandsteelproducts. C. ASTM A229–Steelwire,oil-temperedfor mechanicalsprings. D. ASTM A-653-94–Steelsheet,zinc-coated [galvanized]bythehot-dippedprocess, commercialquality. E. UL10B–Underwriters’Laboratories(UL)FireTests ofDoorAssemblies F. NFPA 80–NationalFireProtectionAgency–Fire DoorsandOtherOpeningProtectives G. ASTM C 612–StandardspecificationforMineral FiberInsulation H. ASTM E-136–Non-combustibleratingfor mineralwool I. ASTM E-84–Flamespreadandsmokedevelopment, surfaceburningcharacteristicsofbuildingmaterials.
1.04 Quality Assurance A. Rollingdoorsandallaccessoriesandcomponents requiredforcompleteandsecureinstallationsshallbe manufacturedasasystemfromonemanufacturer.
1.05 Systems Description A. RollingDoor:Type: Model 700C B. Mounting:[steel][masonry][drywalloverminimum 16-gaugesteelstudsorwoodstuds]jambs C. Operation:[chainhoist][motor][crank]
[motorwithchainhoist] D. Material:Galvanizedsteelwithpolyesterfinishpaint
1.06 Submittals A. ShopDrawings:Clearlyindicatethefollowing: 1. Alldetailsrequiredforcompleteoperation andinstallation. 2. Hardwarelocations. 3. Typeofmetalandfinishfordoorsections. 4. Finishformiscellaneouscomponentsand accessories. B. ProductData:Indicatingmanufacturer’sproduct data,andinstallationinstructions.
1.07 Delivery, Handling, Storage A. Deliverproductsinmanufacturer’soriginal containers,dry,undamaged,sealsandlabelsintact. B. Storeandprotectproductsinaccordancewith manufacturer’srecommendations.
1.08 Warranty A. Standardmanufacturer’soneyearwarrantyagainst defectsinmaterialandworkmanship.
PART I I – PRODUCTS 2.01 Curtain A. Curtainwillbecomposedofinterlocking#14flatslats [22,20,18gaugegalvanizedsteel][22,20stainless steel]slatswith[24-gauge][22-gauge]backslats, roll-formedperASTMstandards.Theareabetween the#14exteriorslatandthebackslatwillbefilledby non-combustiblemineralwoolinsulationwith0flame spread,0smokedevelopment,providinganR-valueof 5(U=0.2).Endsofalternateslatswillbefittedwith metalendlocks. B. BottomBarwillconsistoftwoequalsteel [stainlesssteel]angles,.121”minimum thickness,tostiffencurtain,withoptional astragal.Whenrequiredforadditionalsecurity, provide[slidebolts][cylinderlocks]onthebottom baroperablefrom[coilside][bothsides].
2.02 Guides A. Guideswillberoll-formedsteelstructuralgrade,three angleassemblyofsteel[stainlesssteel]toformaslot ofsufficientdepthtoretaincurtainsinguidesandto allowexpansionatallboltconnections.(Perimeter brushsealsmaybeinstalledtoreducesmoke/air infiltrationarounddooropening)
2.03 Brackets A. Bracketswillbeof3/16”[1/4”]minimumthicksteel plates,withpermanentlysealedballbearings.Designed toencloseendsofcoilandprovidesupportfor counterbalancepipeateachend.
2.04 Counterbalance A. Curtaintobecoiledonapipeofsufficientsizeto carrydoorloadwithdeflectionnottoexceed.033” perfootofdoorspanandtobecorrectlybalancedby helicalsprings,oiltemperedtorsiontype.Castiron barrelplugswillbeusedtoanchorspringstotension shaftandpipe.
2.05 Hood A. Hoodwillbeminimum24-gauge[galvanized] [stainlesssteel]sheetmetal,flangedattopfor attachmenttoheaderandflangedatbottomto providelongitudinalstiffness.Hoodwillenclosecurtain coilandcounterbalancemechanism.AllFMhoods willbefurnishedwithasteelhoodbaffle.
2.06 Finish A. Shopcoatofrustinhibitiveprimeronnon-galvanized surfacesandoperatingmechanisms.Guidesand bracketplateswillbecoatedwithaflatblackprime paint.Stainlesssteelfinishavailable.Curtaincolorwill be[white][blue][gray][beige][brown](white,blue, beige,brownonlyavailableas22gauge).Powder coatingisavailablein180colors.
2.07 Operation A. Doorwillbeoperatedbymeansof[chainhoistwith geardrivereduction][motoroperation][crank]. Optional[electrical][pneumatic]sensingedgetobe attachedtobottombarto[stop][stopandreverse] thedoorwhenitcontactsanobjectduringthe closingcycle.
2.08 Release Mechanism A. DoorswillbeequippedwithFireStarrelease mechanism,requiringonlyonecabletoberoutedto theoperatedside(cablenotrequiredtoberoutedto adjustingwheelside.)Doorswillclosebyathermally actuatedlinkratedat165degreesF,orbyanoptional listedreleasingdevice,orbymanuallyoperatingthe
releasehandle.Allspringtensionshallbemaintained whenthereleasemechanismisactivated.After closingbymanualoperationofreleasehandle,the doorshallbeabletoberesetbyonepersonfrom onesideofthedoor(re-engagingthereleasehandle).
2.09 Governor A. Ifrequiredbythesizeofthedoor,aviscousgovernor willbefurnishedtoregulatetherateofdescentofthe doorinaquietmanner.Itwillbetheengagement typewhichisnotengagedduringnormaldoor operation,butwhichaftercablerelease,willretard thespeedduringautomaticdoorclosuretounder2’ persecondandnotlessthan6”persecond.
2.10 Labels A. Rollingfiredoorswillbearthe¾(three-quarter) hour,11⁄2(oneandone-half)hour,or3(three)hour labelprovidedtheyare<=12’high,<=13’6”wide. Theywillbearanoversizetagiftheyareover12’high or13’6”wide.Rollingfiredoorswillbemanufactured instrictaccordancewiththerequirementsof UnderwritersLaboratories-listedproceduresor FactoryMutual-approvedprocedures,andwillbear theULorFMlabel(tag).FMlabelisavailableforthe 3-hourfiredooronly. 2.11 Locking A. [Chain-hoistdoorwillhavechainkeeperssuitablefor padlocksbyothers.][Electric-motoroperationdoors willlockthroughtheoperatorgearing.][Cylinder lockscanbeprovidedwiththedoors.] Note: Whenspecifyinglocksonelectric-motoroperated doors,electricinterlocksshouldalsobespecifiedto preventoperationwhenlockboltsareengagedinthe guides,thuspreventingdamagetothecurtain and/oroperator.
PART III – EXECUTION 3.01 Installation A. General: 1. Installtherollingfiredoorsinaccordancewith Wayne-DaltonCorp.instructionsandstandards andinaccordancewiththestandardsofthe NationalFireProtectionAssociationStandard80 (NFPA80).Installationandannualmaintenancewill onlybebyatraineddoorsystemstechnician. 2. Verifythatexistingconditionsarereadytoreceive rollingdoorwork. 3. Beginningofrollingdoorworkmeansacceptance ofexistingconditions. B. Fit,align,andadjustrollingdoorassembliesleveland plumbforsmoothoperation. C. Uponcompletionoffinalinstallation,lubricate,test andadjustdoorstooperateeasily,freefromwarp, twistordistortionandfittingforentireperimeter. Note: Architectmayconsiderprovidingaschedulewhen morethanonerollingdoororopeningtype isrequired.
3.02 Testing A. Rollingsteelfiredoorswillbedrop-testedin accordancewithNFPA80andwitnessed,attestingto theirsuccessfuloperationatthetimeofinstallation.
3.03 Maintenance A. PerNFPA80,paragraph15-24.3:Allhorizontalor verticalslidingandrollingfiredoorsshallbeinspected andtestedannuallytocheckforproperoperationand fullclosure.Resettingofthereleasemechanismshall bedoneinaccordancewiththemanufacturer’s instructions.Awrittenrecordshallbemaintainedby thebuildingownerandmadeavailabletotheauthority havingjurisdiction.
Distributed By:
For technical information, visit:www.wayne-dalton.com/commercial
Becauseofcontinuingproductimprovements,wereservetherighttochangetheproductspecificationsanddesignswithoutpriornotice.
FIRESTAR® 700C SERIESNote to specifiers: Wordsinbracketsindicatefrequentlyspecifiedandhighlyrecommendedoptions.
©2012Wayne-Dalton,adivisionofOverheadDoorCorporation.Consistentwithourpolicyofcontinuingproductimprovement,wereservetherighttochangeproductspecificationswithoutnoticeorobligation.Item33912204/12
top related