gc column selection chart

Post on 04-Feb-2022

21 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Zebron, Inferno, Guardian, WAXPLUS, and MultiResidue are trademarks of Phenomenex, Inc. © 2010 Phenomenex, Inc. All rights reserved.

GC Column Selection ChartThe polarity scale is based on their McReynolds value, which provides a systematic approach to ranking GC stationary phases by polarity.

2007WINNER

PO48

8111

09_L

ApplicationsColumn ProfileComposition Specifications Benefits

O O

H

H

H

H

C C

O O

H

H

H

H

C C

O O

H

H

H

H

C C

Si O

CH3

CH3

Si O

Si O

(CH2 )3

NC

Si OSi O

CH3

CH3

Si O

CH3

CH3

Si OSi O

CH3

CH3

Si O

(CH2 )3

NC

Si O

CH3

CH3

Si OSi O

CH3

CH3

Si OSi O

CH3

CH3

Si O

CH3

CH3

Si O

CH3

CH3

Si OSi O

CH3

CH3

Si O

CH3

CH3

Si O

CH3

CH3

Si O

CH3

CH3

Pola

rity

Scale

136 %94 %

Dimethylpolysiloxane Cyanopropylphenyl

Temperature limits -20 to 260 °C

USP phase G43Available with Guardian™ integrated guard columns

Formulated for low bleed•

Increased temperature limit speeds run times and re-equilibration•

Available in Fast GC dimensions•

Separate volatile organic flavor and fragrance additives and residual solvents •in industrial or pharmaceutical products (OVIs)

Volatile organic •compounds (VOCs)Residual solvents in •pharmaceutical products (OVIs)

US EPA Methods 501.3, •502.2, 503.1 524.2, 601, 602, 624, 8010, 8015, 8020, 8021, 8240, 8260

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Optimized for separating volatile organic compounds (VOCs)

~exclusive~

11 ProprietaryTemperature limits - 60 to 320/340 °C (isothermal/TPGC)

EPA Method 8081A, 8141, 8151 Certified

Designed for the separation of all types of pesticides, herbicides, and •insecticides

Provides baseline resolution and confirmation of all 20 chlorinated pesticides •regulated under EPA Method 8081 in ≤10 min

MS Certified phase provides low bleed performance for pesticide confirmation •by MS

Low activity, decreased breakdown of sensitive pesticides such as DDT•

Organochlorine pesticides•Organophosphorus •pesticidesNitrogen containing •pesticidesHerbicides•

Insecticides•Aroclors/PCBs•Multi-pesticide residue •methodsHaloacetic acids •

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Novel phase designed for pesticides, herbicides, and insecticides

~exclusive~

~exclusive~

~exclusive~

~exclusive~

15 Proprietary

Temperature limits - 60 to 320/340 °C (isothermal/TPGC)

EPA Method 8081A, 8141, 8151 Certified

Designed for the separation of all types of pesticides, herbicides, and •insecticides

Provides baseline resolution and confirmation of all 20 chlorinated pesticides •regulated under EPA Method 8081 in ≤10 min

MS Certified phase provides low bleed performance for pesticide confirmation •by MS

Low activity, decreased breakdown of sensitive pesticides such as DDT•

Organochlorine pesticides•Organophosphorus •pesticidesNitrogen containing •pesticidesHerbicides•

Insecticides•Aroclors/PCBs•Multi-pesticide residue •methodsHaloacetic acids•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Novel phase designed for pesticides, herbicides, and insecticides

82007

WINNER

2009WINNER

2009WINNER

5 %95 %Dimethylpolysiloxane Phenyl

Temperature limits -60 to 400/430 °C (isothermal/TPGC)*

USP phase G27Available with Guardian™ integrated guard columns*0.53 mm ID columns are rated to 400 °C max operational temperature

Non-metal 5 % - phenyl - 95 % - dimethylpolysiloxane phase stable to •430 °C

Rugged high temperature, polyimide coated, fused silica tubing•

Provides true boiling point separation for hydrocarbon distillation methods•

Provides robust column performance for high temperature bake outs•

High boiling petroleum •productsSimulated distillation •methodsPolymers/Plastics•High molecular weight waxes•

Triglycerides•Diesel fuel•Motor oils•Surfactants•Long-chained hydrocarbons•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlItyHigh temperature stability (430 °C) for high boiling compounds

85 %95 %

Dimethylpolysiloxane Phenyl

Temperature limits -60 to 360/370 °C (isothermal/TPGC)

USP phase G27Available with Guardian™ integrated guard columns

Highly inert – improved peak shape for acidic/basic compounds•

MS certified low-bleed levels provide maximum sensitivity•

Industry leading QC specifications ensure column-to-column performance•

Traditional bonding chemistry provides the same selectivity as the ZB-5 •columns

Drugs of abuse•Nitrosamines•Phenols•

FAMEs•Pesticides•EPA Methods•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Low-bleed column with the same selectivity as the ZB-5

9 ProprietaryTemperature limits - 60 to 340/360 °C (isothermal/TPGC)*

Available with Guardian™ integrated guard columns*Thicker films (≥1.0 µm df) are rated to 320/340 °C (isothermal/TPGC).

Temperature limits - 60 to 400 °C (isothermal/TPGC)Available with Guardian™ integrated guard columns

Unique low polarity si-arylene column for MS detectors•

Provides alternative selectivity to standard 5-type phases•

Often used for confirmation of pesticide, PCB, or other environmental samples•

Good tool for sample screening to identify unknown contaminants•

Non-metal si-arylene GC column stable to 400 ˚C•

Good tool for general screening to identify unknown samples•

Individually tested for low bleed, MS certified•

Polychlorinated Biphenyls (PCBs)•Pesticides•Herbicides•

Polychlorinated Biphenyls (PCBs)•Pesticides•Herbicides•EPA Methods•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Low polarity si-arylene column with bleed and sensitivity levels designed for MS detectors

Enhanced durability with 400 ˚C temperature stability

85 %95 %

Dimethylpolysiloxane Phenyl-Arylene

Temperature limits -60 to 325/350 °C (isothermal/TPGC)

USP phase G27Available with Guardian™ integrated guard columns

Low bleed (MS certified) especially suited to high sensitivity work using •GC/MS

Extremely inert for active compounds such as drugs or pesticides•

Fully conditioned within 35 minutes•

Enhanced resolution of PAHs and other multi-ring aromatic compounds•

Drugs•Amines•Alkaloids•FAMEs•Halo-hydrocarbons•Dioxins•

Polyaromatic •hydrocarbons (PAHs)Polychlorinated biphenyls •(PCBs)/AroclorsAcids•Pesticides/Herbicides•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Arylene phase for enhanced resolution of PAHs and multi-ring aromatic compounds

85 %95 %

Dimethylpolysiloxane Phenyl

Temperature limits -60 to 360/370 °C (isothermal/TPGC)*

USP phase G27Available with Guardian™ integrated guard columns*Thicker films (≥1.0 µm df) are rated to 340/360 °C (isothermal/TPGC).

Low bleed (MS certified) especially suited to high sensitivity work using •GC/MS

Extremely inert for active compounds such as drugs or pesticides•

Resilient to dirty samples – long column life•

Great column for unknown samples•

Alkaloids•Drugs•FAMEs•Halo-hydrocarbons•Phenols•Pesticides/Herbicides•

Residual solvents•PCBs/Aroclors•Essential oils/Flavors•Semi-volatiles•Dioxins•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Versatile low polarity column for unknown samples

5100 %Dimethylpolysiloxane

Temperature limits -60 to 400/430 °C (isothermal/TPGC)*

USP phase G2Available with Guardian™ integrated guard columns*0.53 mm ID columns are rated to 400 °C max operational temperature

Non-metal 100 % dimethylpolysiloxane phase stable to 430 °C•

Rugged high temperature polyimide coated, fused silica tubing•

Provides true boiling point separation for hydrocarbon distillation methods•

Provides robust column performance for high temperature bake outs•

High boiling petroleum •productsSimulated distillation •methodsLong-chained hydrocarbons•

Polymers/Plastics•High molecular weight waxes•Diesel fuel•Motor oils•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlItyHigh temperature stability (430 °C) for non-polar compounds

5100 %Dimethylpolysiloxane

Temperature limits -60 to 360/370 °C (isothermal/TPGC)*

USP phase G2Available with Guardian™ integrated guard columns

Lowered bleed (MS certified) especially suited to high sensitivity work using •GC/MS

Extremely inert for active compounds such as drugs or pesticides•

Improved signal-to-noise ratio for better sensitivity and mass spectral •integrity

Identical selectivity to ZB-1•

Drugs of abuse•Amines•Acids•Polychlorinated biphenyls •

(EPA Method 1668)Flavors & fragrances•Diesel fuel•Pesticides•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Extremely low bleed column for non-polar compounds

5100 %Dimethylpolysiloxane

Temperature limits -60 to 360/370 °C (isothermal/TPGC)*

USP phase G2*Thicker films (≥1.0 µm df) are rated to 340/360 °C (isothermal/TPGC).

Low activity•

High efficiency•

Excellent resolving power of critical pairs in complex petrochemical samples •

Low bleed (MS certified)•

Essential oils•Gases (refinery) •Hydrocarbons•MTBE •Natural gas odorants•

Oxygenates and GROs•Semi-volatiles•Simulated distillation•Sulfur compounds (light)•Solvent impurities•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Non-polar phase suited for true boiling point separations

1835 %65 %

Dimethylpolysiloxane Phenyl

Temperature limits 50 to 340/360 °C (isothermal/TPGC)

USP phase G42

Temperature limits -60 to 400 °C (isothermal/TPGC)

USP phase G42

Intermediate polarity column for high molecular weight analysis•

Inert to minimize analyte adsorption, improve efficiency, and reproducibility•

More rugged (longer column life) than other polar phases•

Often resolves compounds that co-elute on ZB-1 or ZB-5 phases•

First non-metal, 35 %-Phenyl columns stable to 400 ˚C•

Great for high molecular weight compounds•

Individually tested for low bleed, MS certified•

Pesticides•Aroclors•Drugs of abuse•

Amines•Semi-volatiles•Steroids•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Intermediate polarity column for high molecular weight

1914 %86 %

Dimethylpolysiloxane Cyanopropylphenyl

Temperature limits -20 to 280/300 °C (isothermal/TPGC)

EPA Method 8081A Certified*Thicker films (≥ 1.0 µm df) are rated to 260/280 °C (isothermal/TPGC).

Specially tested to ensure good response for DDT and endrin•

Guaranteed column for pesticide analysis•

Organochlorine pesticides•Aroclors•Organophosphorus •pesticides

Nitrogen containing •pesticidesPolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Specially tested to ensure good response for DDT and endrin

2450 %50 %PhenylDimethylpolysiloxane

Temperature limits 40 to 320/340 °C (isothermal/TPGC)

USP phase G3

High polarity column capable of high temperature bake-out to remove •contaminants

Inert to minimize analyte adsorption, improve efficiency, and reproducibility•

More rugged (longer column life) than other polar phases•

Great for drug screening and environmental compounds•

Drugs of abuse•Pesticides/Herbicides•Aroclors•Antidepressants•

Cholesterols•Triglycerides•Steroids•Glycols•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

High polarity column capable of high temperature bake-out to remove contaminants

52100 %Polyethylene Glycol

100 % aqueous stable•

Extremely inert for acidic compounds•

Enhanced selectivity for low boiling solvents•

High retention of alcohols and chlorinated solvents•

Alcohols•Aldehydes•Aromatics•Essential oils•Flavors & fragrances•Glycols•

Pharmaceuticals•OVIs•Solvents•Styrene•Xylene isomers•Alcoholic beverages•

Temperature limits 20 to 250/260 °C (isothermal/TPGC)

USP phase G16PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

100 % aqueous stable with high retention of alcohols and chlorinated solvents

57100 %Polyethylene Glycol

Temperature limits 40 to 250/260 °C (isothermal/TPGC)

USP phase G16

Low bleed; MS certified•

Highly stable, long lifetime•

Low activity for amines•

Excellent chromatography of polar complex mixtures•

Alcohols•Aldehydes•Aromatics•Essential oils•Flavors & fragrances•Glycols•

Pharmaceuticals •Solvents•Styrene•Xylene•Basic compounds •

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Bonded, solvent rinsable phase excellent for separating polar complex mixtures

58Nitroterephthalic Acid Modified Polyethylene Glycol

Temperature limits 40 to 250/260 °C (isothermal/TPGC)

USP phase G35

Temperature limits -20 to 260/280 °C (isothermal/TPGC)

Temperature limits -60 to 320/340 °C

Temperature limits -60 to 340/360 °C (isothermal/TPGC)

High polarity column•

Provides better peak shape for underivatized acids•

Bonded, solvent rinsable •

Replaces OV-351•

Specifically designed for blood alcohol analysis•

More accurate results for post mortem samples •

Resolves t-butanol and n-propanol, for greater selection of internal standards•

Fast run time with baseline resolution of key components in just 2 minutes•

Enhanced resolution of ethanol and acetone peaks•

Provides fast analysis with great peak shape•

Improves resolution of target analytes from matrix interferences•

Specially deactivated to improve quantitation for drug compounds•

Provides accurate and reproducible results for Certificate of Analysis (COA)•

Resolve methanol and ethanol from all other denaturant peaks•

Great resolution of fusel alcohols•

Acrylates•Alcohols•Aldehydes•Flavor mixtures•Free fatty acids•

Ketones•Organic acids•Phenols•Volatile free acids•

Blood alcohol analysis•Glycols•Abused inhalant anesthetics•Industrial solvents•

Drugs of abuse•General drug screen•Designer drugs•

Bioethanol•Alcohol•Fusel alcohols•

ASTM D 5501•ASTM D 4806•prEN 15376•

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

Provides better peak shape for underivatized acids

More accurate results for blood alcohol analysis in post mortem samples

Optimized phase for the separation of drugs of abuse

Fast and accurate bioethanol analysis

Polarity Scale

Pro

pri

etar

yP

ola

rity

Scale

Pola

rity

Scale

1835 %65 %

Dimethylpolysiloxane Phenyl

PolaRIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

9 Proprietary

loW HIgH

Enhanced durability witih 400 ˚C temperature stability

Aroclors•Semi-volatiles•Amines•EPA Methods 508, 608, •8081, 8141, 8151

Pesticides•Drugs of abuse•Pharmaceuticals•Steroids•Chemicals•

Note: Consider using ZB-MultiResidue 1 and 2 as a more rugged alternative for pesticide analysis.

Proprietary

Proprietary

Proprietary

ZB-1

ZB-1ms

ZB-1Ht INFERNo™

ZB-5

ZB-5ms

ZB-5msi

ZB-5Ht INFERNo™

ZB-XlB

ZB-XlB-Ht INFERNo™

ZB-multiResidue™-1

ZB-624

ZB-multiResidue™-2

ZB-35

ZB-35Ht INFERNo™

ZB-1701P

ZB-50

ZB-WaXPLUS™

ZB-WaX

ZB-FFaP

ZB-BaC1 & 2

ZB-dRug-1

ZB-BIoEtHaNol

www.phenomenex.com

BlEEd

tEmPERatuRE lImIts

staBIlIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

BlEEd

tEmPERatuRE lImIts

staBIlIty

top related