2010

-07

HAMMAR LIFEBUOY RELEASE SYSTEMINSTALLATION MANUAL

Specification:• OneGRPholderwithpre-installedmetalholderandbracket.• OneERU(electricremoteunit)withcordpre-installedonmetalholder.• OneReleaseSwitch• OneConnectorbox• 20mcablefromconnectorboxtoreleaseswitch,screened2x0,75mm2,diameter8mm• Onemanualsafetypin• Onepilotlineforloadingthelifebuoy• Oneinstallationmanual• OneUserGuide• OnemarkinginstructionNot supplied in the kit from CM Hammar:•Lifebuoy•Mountingboltsfortheinstallationonboard

Installation:1. MounttheGRPholderinapositionsothatareleasedlifebuoywilleasilyfallintothewater.

2. Followtheinstructionsforthemountingboltsaccordingtothepictures.MakesurethatyoumountdoublewashersbetweenframeorbulkheadandtheGRPholder.

2010

-07

3. MounttheconnectorboxnearbytheGRPholder.MakesurethatthecablefromtheERUwillreachtheconnectorbox.

4. InstallthescreenedcablefromtheconnectorboxtotheReleaseSwitch.

5. MounttheReleaseSwitchinapositionsoitiseasytolocateandmanageit.TheReleaseSwitchshallbemountedinsidethewheel-houseorbridge.

6. Connect24Vemergencypower to theReleaseSwitch.Seeattachedconnectiondrawing.Test theelectricalinstallationaccordingtoinstructionondrawing.

7. TheERUispre-installed.TheERUmustbemarkedwithitsexpirydate2yearsfrominstallationonboard.Followtheenclosedmarkinginstruction.Ahydrostaticreleaseunit,whichisnotproperlymarkedwithitsdateofexpiry,isnotapproved.

8. Puta lifebuoy into theGRPholder,butonly2/3 into theholderandthensecure itwithacordorbyhand.Usethesuppliedthinwhitepilot linetopull thereleasecordthroughtheH20ERUunit.Makesurethatthelifebuoylineisnotontheoutwardsideofthereleasecord!

2010

-07

9. PullupthereleasecordthroughtheERUholewiththepilotline.Secureitwiththemanualsafetypin.

10.Connectthepower.

11.ThesafetylidontheReleaseSwitchcanbesecuredwithsomekindofeasy-to-breakseal,inordertoavoidunintentionaluseofthesystem.

12.Thesystemisnowreadytobeused.TheERUshallbechangedaftertwoyearsofservice.

2010

-07

190780

958

510650

60

800

16060

670

680

540

M8(x5)

GRP HOLDER DRAWING

2010

-07

CONNECTOR BOX DRAWING55

55 38 45

45 4,30

Front side Back

tor.ctor.c

1

CM HAMMAR ABTel.: +46 31 709 65 50 Fax.: +46 31 49 70 23

Drawn/Ritad Checked/Kontr. Appr./Godkänd Scale/skala Repl./Ersätter: Date/Datum: (dd-mm-yyyy)

Draw.No./Ritn.nr.

Det. Number/ant. Designation/benämn.

Sheet1

Notes/noteringarMaterial

tor.c 10-07-2009

A010007-01

1:1

CONNECTOR BOX ERU

Rev.: 1of

2010

-07

RELEASE SWITCH DRAWING

7

87

87

tor.ctor.c

1

CM HAM

MAR AB

Drawn/Ritad

Checked/Kontr.

Appr./G

odkändDate/Datum

:Repl./Ersätter:

Scale/skalaDraw

.No./Ritn.nr.

Det.Num

ber/ant.Designation/benäm

n.M

aterialNotes/noteringar

RELEASE SWITC

H - DIMENSIO

NS

Sheet1

A010031

tor.c10-07-2009

1:1

Tel.: +46 31 709 65 50 Fax.: +46 31 49 70 23

Rev.:1of

82

MA

XIMUM

DIA

METER FO

R CA

BLE 12 mm

102

102

2010

-07

WIRING CONNECTION DIAGRAM ERU

1

2

3

4

5Note 1

12

34

56

Terminals

+24VDC

0VDC+ERU outp.

- ERU outp.(- ERRS)

(+ ERRS)

Optional connection to ERRS System

, Terminal No:

2 to + output ERRS System (upper term

inals 1-10 in ERRS control box)5 to - output ERRS system

(Lower term

inals 1-10 in ERRS control box)

POW

ER SUPPLY, Terminal No:

1 to +24VDC

EMERG

ENCY PO

WER SYSTEM

4 to 0VDC

EMERG

ENCY PO

WER SYSTEM

TESTING THE INSTALLATIO

N:The correct function of the HAM

MAR ERU RELEASE SW

ITCH can be tested by

connecting a 200 mAF 5x20 m

m glass tube fuse to the ERU RELEASE SW

ITCH

output instead of the pos. 1 ERU unit. The fuse blows off w

hen the ERU RELEASE SW

ITCH push button is pressed if the system

is correctly installed.

CM HAM

MAR AB

Drawn/Ritad

Checked/Kontr.

Appr./Godkänd

Date/Datum: (dd-m

m-yyyy)

Repl./Ersätter:Scale/skala

Draw.No./Ritn.nr.

Det.Num

ber/ant.Designation/benäm

n.M

aterialNotes/noteringar

Tel.: +46 31 709 65 50 Fax.: +46 31 49 70 23

HAMM

AR H20 ERU - RELEASE SWITC

H 24VDC

- CO

NNECTIO

N DIAGRAM

ERU1001

tc03-10-2007

Rev.:5

tctc

Sheet11

of

POS 1: HAM

MAR ELEC

TRIC RELEASE UNIT (ERU), operating voltage 10 - 15VD

C, 3A

POS 2: HAM

MAR ERU C

ONNEC

TION BO

XPO

S 3: HAMM

AR ERU RELEASE SWITC

H 24VDC

Input voltage 18VDC

- 32VDC

Max. interm

ittent load 3APO

S 4: Cable, 2 x 0,75 m

m2 (screened). O

uter diameter 5-10 m

m.

POS 5: C

able, 4 x 0,75 mm

2 (screened). Outer diam

eter 5-12 mm

or C

able, 2 x 0,75 mm

2 (screened). Outer diam

eter 5-12 mm

.

Note 1: When connecting the cable from