AVENANT D'ATTESTATION D'EXAMEN DE TYPE VOLONTAIRE
VOLUNTARY SUPPLEMENTARY EXAMINATION CERTIFICATE
TYPE
2 Apparell destine a etre utilise en atmospheres explosibles (Directive 94191CE)
2 Equipment intended for use in potentially explosive atmospheres (Directive 94191EC)
3 Numero de I'avenant : 3 Supplementary certificate number: LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
4 Appareil 4 Equipment Automates Programmable controllers
Type: 175611757, 1771117S5, 1794, 17S4, 1786 et 1788 Type : 175611757, 1771117S5, 1794, 17S4, 17S6 and 1788
5 Demandeur : Rockwell Automation Inc. 5 Applicant: Rockwell Automation Inc.
6 Adresse : 1, Allen Bradley Drive 5 Applicant: 1, Allen Bradley Drive Mayfield Heights, OHIO 44124 USA
Mayfield Heights, OHIO 44124 USA
15 DESCRIPTION DE L'AVENANT 15 DESCRIPTION OF THE SUPPLEMENTARY CERTIFICATE
Mise a jour normative selon les normes EN 60079-0 (2009) et EN 60079-15 (2010) Ajout du modele 1756-A7XT Suppression des modeles 1756-IA161, 1756-IA8D, 1756-OA161 , 1756-0ASD, 1756-0W161, 1756-0XSI, 1756-PA75, 1756-PA75RK, 1756-PB75RK, 1794-AENT, 1794-APBDPV1, 1794-IA16, 1794-IAS, 1794IASI, 1794-0A16, 1794-0AS, 1794-0A81, 1794-0M8 Mise a jour de la liste des equipements certifies (voir tableau)
Reference catalogue I Description
Catalog reference
1756-A4 CONTROLLOGIX CHASSIS 4 SLOT
1756-A7 CONTROLLOGIX CHASSIS 7 SLOT
1756-Al0 CONTROLLOGIX CHASSIS 10 SLOT
1756-AI3 CONTROLLOGIX CHASSIS 13 SLOT
1756-A17 CONTROLLOGIX CHASSIS 17 SLOT
1756-A4LXT EXTENDED TEMPERATURE CONTROLLOGIX CHASSIS
1756-A5XT EXTENDED TEMPERATURE CONTROLLOGIX 5 SLOT CHASSIS
1756-A7XT EXTENDED TEMPERATURE CONTROLLOGIX 7 SLOT CHASSIS
17S6-A7LXT EXTENDED TEMPERATURE CONTROLLOGIX CHASSIS
1756-PAXT CONTROLLOGIX POWER SUPPLY (1201240V AC INPUT). EXTENDED TEMPERATURE
1756-PB72 CONTROLLOGIX POWER SUPPLY (24V DC INPUT)
1756·PB7S CONTROLLOGIX POWER SUPPLY (24V DC INPUT)
Normative update according to EN 60079-0 (2009) and EN 60079-15 (2010) Addition of the 1756-A 7XT model Removal of the models 1756-IA161, 1756-IASD, 1756-OA161, 1756-0ASD, 1756-0W161, 1756-0XSI, 1756-PA75, 1756-PA75RK, 1756-PB75RK, 1794-AENT, 1794-APBDPV1, 1794-IA16, 1794-IA8, 17941ASI, 1794-0A16, 1794-0AS, 1794-0A81 , 1794-0M8 Update of the certified equipment list (see table)
Marquage I Fonction I lamb Marking Function
O°C I +60°C 113G Ex nA IIC T4 Gc
O°C I +60°C 113G ExnA IICTS Gc
O°C I +60°C 113G Ex nA IICT5 Gc
O°C I +60°C 113G Ex nA IIC T5 Gc
O°C I +60°C 113G Ex nA IICTS Gc Chassis
-25°C I +60°C 113G Ex nA IIC T5 Gc
-25°C I + 70°C 113G Ex nA IIC T5 Gc
-2SoC I + 70°C 113G Ex nA IIC T4 Gc
-25°C I +60°C 113G ExnA IICTS Gc
-2SoC I + 70°C 113G Ex nA IIC T4 Gc
O°C I +60°C 113G Power Ex nA IIC T4 Gc Supply
O°C I +60°C 113G ExnA IIC T4 Gc
Seul le laxle en f(an~als peul engager la responsabilite du lCIE. Ce document ne peul ette reproduil que dans son Inlegralite. sans aucune modificaUon. The LCIE's liability appUes only on the French texl. This document may only be reproduced in its entirety and without any change.
1;,11111 ,lIoin' ( l 'ull ,d 1',1'
d t" Indll ' " i l " li n _II iepl L" ' "" , ,I ,,1110 I I ,I~ ,111\ I". ",I.
I li t:' ..,1It: i l' I t:: ek IlIlrl';m \ e l iL " Ie
I, I " I I"" I 1'1
:11 I I, It
I' \ • I ( I,
Page 1 sur 11 !' \.11' ',' 'HII 03A·Annexe IIUyp_app_av - rev2.DOC
I 'II' ,I (
13 ANNEXE 13 SCHEDULE
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite) : Certified equipment list (continuation) :
Reference catalogue Marquage I Fonetlon I I Description Tamb
Catalog reference Marking Function
1756·PBXT CONTROLLOGIX EXTENDED TEMPERATURE ·25°C I + 70°C
113G POWER SUPPLY (24V DC INPUT) Ex nAIiC T4 Gc
1756·PSCA POWER SUPPLY ADAPTER MODULE O°C I +ao°c 113G Power ExnA IIC T5Gc Supply
1756·PSCA2 REDUNDANT POWER SUPPLY CHASSIS O°C I +60°C 113G ADAPTER ExnA IIC T5Gc
1756·L1 LOGIX 5550 AUTOMATION CONTROLLER
O°C I +60°C 113G WITH 160 KBYTE MEMORY ExnAIICT4Gc
1756·L55 LOGIX5555 0.5MBYTE CONTROLLER O°C I +60°C 113G
Ex nA IIC T4 Gc
1756·L61 LOGIX 5561 CONTROLLER O°C I +60°C 113G Ex nA IIC T4 Gc
1756·L62 LOGIX 5562 CONTROLLER O°C I +60°C 113G ExnA IIC T4 Gc
1756·L63 LOGIX 5563 CONTROLLER O°C I +60°C 113G Ex nA IIC T4 Gc
1756·L63XT EXTENDED TEMPERATURE LOGIX 5563 ·25°C I + 70°C
113G CONTROLLER Ex nA IICT4 Gc
113G Controller
1756·L71 CONTROLLOGIX 2 MB CONTROLLER O°C I +60°C Ex nA IICT5 Gc
1756·L72 CONTROLLOGIX 4 MB CONTROLLER O°C I +60°C 113G Ex nA IIC T5 Gc
1756·L73 CONTROLLOGIX 8 MB CONTROLLER O°C I +60°C 113G Ex nA IICT5 Gc
1756·L74 CONTROLLOGIX 16 MB CONTROLLER O°C I +60°C 113G ExnA IICT5 Gc
1756·L75 CONTROLLOGIX 32 MB CONTROLLER O°C I +60°C 113G Ex nA IIC T5 Gc
1756·L76 CONTROLLOGIX 64 MB CONTROLLER O°C I +60°C 113G Ex nA IIC T5 Gc
AUTOMATION CONTROLLER FOR 113G 1756·M1 CONTROLLOGIX· MEMORY EXPANSION O°C I +60°C
ExnA IIC T4 Gc BOARD 512K BYTE
AUTOMATION CONTROLLER FOR 113G 1756·M2 CONTROLLOGIX· MEMORY EXPANSION O°C I +60°C
Ex nA IICT4 Gc BOARD 1 M BYTE
AUTOMA liON CONTROLLER FOR 113G 1756·M3 CONTROLLOGIX· MEMORY EXPANSION O°C I +60°C
Ex nA IIC T4 Gc Memory BOARD 2M BYTE
1756·M12 LOGIX 5555 NON VOLATILE MEMORY 750KB O°C I +60°C 113G Ex nA IIC T4 Gc
1756·M13 LOGIX 5555 NON VOLATILE MEMORY 1.5MB O°C I +60°C 113G Ex nA IICT4 Gc
1756·M14 LOGIX 5555 NON VOLATILE MEMORY 3.5MB O°C I +60°C 113G Ex nA IIC T4 Gc
Seu! Ie (exle en franc;ais peul engager la responsabilile du LCIE. Ce document ne peul etre reproduil Que dans son Inlegralile , sans aucune modificaUon. The LCIE's liability applies only on the French text. This document may only be reproduced In lIs entirely and without any change.
Page 2 sur 11 OJA·Annexe II Uyp_app_av - rev2_DOC
(I 1---1
13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite) : Certified equipment list (continualion) :
I Marquage I Fonction I I Description Tamb Marking Function
1756-M16 LOGIX 5555 NON VOLATILE MEMORY 7.5MB O°C / +60°C Ex n~II~C GT4 Gc
1756·M22 LOGIX 5555 NON VOLATILE MEMORY 750KB O°C / +60°C Ex n~ll~cGT4GC Memory
1756-M23 LOGIX 5555 NON VOLATILE MEMORY 1.5MB O°C / +60°C Ex n~ll~cGT4 Gc
1756-M24 LOGIX 5555 NON VOLATILE MEMORY 3.5MB O°C / +60°C Ex n~ll~cGT4 Gc
1756-CNB CONTROLNET COMMUNICATIONS MODULE O°C / +60°C Ex n~II~C~4 Gc
1756-CNBR rm'MI IW
" '.~~~~~J O°C / +60°C Ex n~ll~cGT4 Gc
1756-CN2 CONTROLNET COMMUNICATIONS MODULE O°C / +60°C Ex n~ll~cGT4 Gc
1756-CN2R rn"",I."r;AT~~~~ ~~~~~~ O°C / +60°C Ex n~ll~cGT4 Gc
1756-CN2RXT c~~'t~~L~~+ ~IVI""R~~~~~ION~~E -25°C / + 70°C Ex n~ll~cGT4 Gc
1756-DHRIO CON~~O~M~DULE HE O°C / +60°C Ex n~ll~cGT4GC 1756-DHRIOXT
EXTEN~EA~; rU~EOC?r-I!~o -25°C / + 70°C 113G
~;'MMI I - ~~;;~~,~, ~ Ex nA IIC T4 Gc
1756-0NB 1756-DEVICENET SCANNER O°C / +60°C Ex n~ll~cGT4 Gc Communic alian
1756-ENBT vV" I ",:,;:;,' ,~~~"~ "," 10/100 O°C / +60°C Ex n~II~C~4 Gc
1756-ENET ETHERNET COMMUNICATIONS ADAPTER O°C / +60°C Ex n~ll~cGT4 Gc
1756-EN2F VU" II OPTIC I,;~~~~~ 011~::~gR FIBRE O°C / +60°C Exn~ll~cGT4 Gc
1756-EN2T VUIV I MODULE.C~~';~~~ 10/100 O°C / +60°C Ex n~\~c GT4 Gc
1756-EN2TR 1011'Q~~,';'~'1I ~. RO~S~ ~~~~NCIII" O°C / +60°C Ex n~'I~cGT4 Gc
1756-EN2TXT c~~~~~~~T;IP 10/100'~~~ IT~~~H DDR -25°C / + 70°C Ex n~ll~cGT4 Gc
1756-EN3TR "CONT I MOD~L~.';~;NC 1I1~ O°C / +60°C Ex n~II~C~4 Gc
1756-EWEB WEB SERVICES 10/100 ETHERNET MODULE O°C / +60°C Ex n~II~C~4 Gc
1756-IB16 24 V DC INPUT MODULE (16 PT.) O°C / +60°C EX_~~'I~CGT3GC 1756-IB16D 10-30 V DC DIAGNOSTIC INPUT (16 PT.) O°C / +60°C Ex n~II~C GT3 Gc
Inpul module
1756-IB161 10-30 V DC ISOLATED INPUT (16 PT.) O°C / +60°C Exn~ll~cGT4GC
Seulle texle en fran~a is peul engager la responsabilit6 du LCIE. Ce document ne peul ~tre reproduit que dans son Integralile , sans aucune modification . The LCIE's liability applies only on the French text. This document may only be reproduced In its entirety and without any change.
Page 3 sur 11 03A-Annexa IIUVp_spp_sv - rev2.DOC
~.~~\ °UV
16?!, *---1 13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite) : Certified equipment list (continuation) :
Reference catalogue Marquage I Fonction I I Description Tamb
Catalog reference Marking Function
1756-IB161S0E 10-55V DC SEQUENCE OF E~)ENTS ISOLATED O°C / +60'C 113G INPUT (16 PT Ex nA IIC T4 Gc
1756-IB32 10-30V DC 32 BIT INPUT MODULE O°C / +60'C 113G Ex nA IIC T4 Gc
1756-IC16 30-60 V DC INPUT (2 X 8 PT.) O'C / +60' C 113 G ExnA IIC T4 Gc
1756-IF16 ANALOG VOLTAGE & CURRENT INPUT O'C / +60' C 11 3G (16 PT.) Ex nA IIC T4 Gc
1756-IF4FXOF2F HIGH SPEED ANALOG I/O MODULE O°C / +60' C 113 G ExnA IIC T4 Gc
1756-IF6CIS CURRENT INPUT WITH SOURCE O°C / +60' C 11 3G Ex nA IIC T4 Gc
1756-IF61 ISOLATED ANALOG VOLT IN (6PT) O'C / +60'C 113G
Ex nA IIC T4 Gc
1756-IF8 ANALOG VOLTAGE & CURRENT INPUT O'C / +60' C 113G Input (8 PT.) ExnA IICT4 Gc module
1756-IG1 6 1756 TTL INPUT MODULE (16 PT) O°C / +60' C 11 3G
ExnA IICT5 Gc
1756-IN16 10 TO 30 V AC ISOLATED INPUT MODULE O'C / +60°C 113G (16 PT.) ExnA IICT3 Gc
1756-IR61 RTD ISOLA TED INPUT (6 PT) O'C / +60' C 11 3G
Ex nA IIC T4 Gc
1756-IT61 THERMOCOUPLE/MV ISOLATED INPUT (6PT) O'C / +60'C 113G ExnA IIC T4 Gc
1756-IT612 THERMOCOUPLE/MILLIVOLT INPUT O'C / +60' C 113G
ExnA IIC T4 Gc
1756-1V16 10 TO 30 V DC SOURCING INPUT (16 PT.) O' C / +60°C 11 3G
Ex nA IIC T4 Gc
1756-IV32 10 TO 30 V DC SOURCING INPUT (32 PT.) O°C / +60' C 11 3G ExnA IIC T4 Gc
1756-0B16D DIAGNOSTIC DC OUTPUT MODULE (16 PT) O°C / +60°C 11 3G
Ex nA IIC T4 Gc
1756-0B16E 10-30 V DC ELECTRONICALLY PROTECTED O°C / +60°C 113G OUTPUT MODULE (16 PT.) ExnA IICT4 Gc
1756-0B161 24 V DC ISOLATED OUTPUT MODULE
O°C / +60°C 11 3G
(16 PT.) Ex nA IIC T4 Gc
1756-0B1 6IS 10-30V DC SCHEDULED OUTPUT MODULE O°C / +60°C 11 3G (2X8 PT.) ExnA IICT4 Gc
1756-0B32 10-31.2V DC OUTPUT MODULE (2 X 16 PT) O°C / +60°C 11 3G Oulpul Ex nA IICT4 Gc module
1756-088 10-30V DC OUTPUT (2 X 4 PT.) O°C / +60°C 113G
Ex nA IIC T4 Gc
1756-0B8EI 10-30V DC E-FUSED OUTPUT (8 PT.) O'C / +60°C 11 3G ExnAIICT4Gc
1756-0C8 30-60V DC OUTPUT (2 X 4 PT.) O°C / +60°C 11 3G Ex nA IIC T4 Gc
1756-0F4 VOLTAGE AND CURRENT OUTPUT (4 PT.) O°C / +60°C 11 3G
ExnA IIC 14 Gc
Seulle lexle en rra~als peul engager la responsabilit6 du l CIE. Ce document ne peul atre reproduil que dans son Integra lite, sans aucune modification . The lCIE's liability applies only on the French text. This document may only be reproduced in its enti rety and without any change.
Page 4 sur 11 03A-Ann8xo IIUyp_app_8v - rev2.DOC
~'''~' .. U· , ' .;, ~. , '.'
I B21.\ 1---1 13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite) : Certified equipment list (continuation) :
Description Tamb Marquage I Fonction I
MarkIng Function
1756·0F6CI ISOLATED ". OUTPUT O'C I +60'C Ex n~ll(cGT4 Gc (6PT)
1756·0F6VI ISOLA TED ANALOG VOLTAGE OUTPUT (6PT) O'C I +60' C E.>< n~II(Q~4 G,,-
1756·0F8 VOLTAGE AND CURRENT OUTPUT (8 PT.) O'C I +60'C Exn~II~~4GC 1756·0G16 1756·0G16 TTL OUTPUT O'C I +60'C Ex n~II(C~5 Gc
OUlput module
1756·0N8 24 V AC OUTPUT MODULE (8 PT.) O'C I +60'C Ex n~ll(cGT4 Gc
1756·0V16E 10 TO 3~1~~I~~L~~~PUT (16 PT ; FUSED O'C I +60' C Ex n~II(C<;'4 Gc
1756·0V32E ELEC1 ",v"I,," Y ~~~~,~, ~0.30 VDC OUTPUT O'C I +60'C Ex n~ll(cGT4 Gc
1756·BATM LOGIX5000 BATTERY MODULE O'C I +60' C Ex n~II(C ~6 Gc
1756·ESMBAT L7X ENERGY STORAGE MODULE BATTERY O'C I +60' C Ex n~ll(cGT5 Gc
1756·ESMCAP "V" , >Ann; ~'~.('~p ~'v"""~ O'C I +60'C Ex n~II(C GT5 Gc
1756·ESMNRM L7X ~"~","T -~-'.':';';:A~ ~'VVV"~ NON O'C I +60'C Ex n~II~CGT5 Gc
1756·ESMNSE "VI" MOD'U~LE~NSE ~ I v"""~ O'C I +60'C Ex n~'t~c GT5 Qf..
1756·HSC HIGH SPEED COUNTER O' C I +60'C Ex n~II~CGT4 Gc
1756·PLS PROGRAMMABLE LIMIT SWITCH O'C I +60'C Ex n~'t~c GT4 Gc
1756·RM SYSTEM REDUNDANCY MODULE O'C I +60'C Ex n~II ~CGT4 Gc
1756·RMXT t"rEN~,,~ . MO~~~E ~ ,~'" ·2S·C I + 70'C Ex n~II(C GT 4 Gc
1757·SRM SYSTEM REDUNDANCY MODULE O'C I +60'C Ex nA ~631~ T4 Gc tion
1771·A1B 4 SLOT 1/0 CHASSIS O'C I +60'C Ex n~II(C GT6 Gc
1771·A2B 8 SLOT 1/0 CHASSIS O' C I +60'C Ex n~II(C~6 Gc Chassis
1771·A3B1 12 SLOT 1/0 CHASSIS O'C I +60'C Ex n~II(C<;'6 Gc
1771·A4B 16 SLOT I/O CHASSIS O'C I +60'C Ex n~ll(cGT6 Gc
1771·P5E POWER SUPPLY O'C I +60'C Ex n~II(C~3 Gc ~~;~;
Seul le lexte en fran<;:ais peu! engager la responsabllile du LC 1E. Ce document ne peul ~Ire reproduit que dans son inlegralile, sans aucune modification. The lCIE's liability applies only on the French text. This document may only be reproduced in Its entirely and without any change.
Page 5 sur 11 03A·Annexe IIUyp_app_aV - fE!v2.00C
I
1 __ -.
13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X 109 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite): Certified equipment list (continuation) :
Reference catalogue Marquage I Fonction I I Description Tamb
Catalog reference Marking Function
1771-ACNR CONTROL NET REMOTE ADAPTER, O'C I +60' C 113G
REDUNDANT Ex nA IIC T5 Gc
1771-ACNR15 CONTROLNET REMOTE ADAPTER,
O' C I +60' C 113G Adapter REDUNDANT ExnA IIC T5 Gc
1771-ASB CONTROLNET REMOTE 10 ADAPTER O'C I +60' C 113G Ex nA IICT5 Gc
1771-IBN 10-30 VDC HIGH TRUE INPUT MODULE, 32 O'C I +60'C
113G INPUT ExnA IICT3 Gc
1771-IFE ANALOG MODULE 161NPUT O' C I +60' C 113G Input Ex nA IIC T5 Gc module
1771-IR INPUT MODULE, RTD, 61NPUT O'C I +60' C 113G
Ex nAIICT4Gc
1771-0BD 10/60 BDC HD OUTPUT O'C I +60' C 113G Ex nA IIC T3 Gc
1771-0BDK 10/60 BDC HD OUTPUT CONFORMALLY O' C I +60' C
113G COATED Ex nA IICT3 Gc
1771-0BDS 10-40VDC HD OUTPUT MODULE, 16 CHANNEL O°C I +60°C 113G ExnA IIC T3 Gc Oulput
1771-0FE1 OUTPUT MODULE - VOLTAGE O' C I +60' C 113G module
Ex nA IIC T5 Gc
1771-0FE2 OUTPUT MODULE - 20 Ma O'C I +60' C 113G Ex nAIiC T5 Gc
1771-0FE3 OUTPUT MODULE - 50 Ma O' C I +60' C 113G Ex nA IIC 14 Gc
1771-CFM CONFIGURABLE FLOW METER O' C I +60' C 113G Accessories
Ex nA IIC T4 Gc
1784-KTCX PEER COMMUNICATION LINK INPUT MODULE OCto50C 113G
ExnA IIC T6 Gc
1784-KTCX15 PEER COMMUNICATION LINK INPUT MODULE OCto 50C 113G Communic
Ex nA IIC T6 Gc alion
1784-PCIC PCI BUS CONTROLNET INTERFACE O' C I +55' C 113G ExnA IIC T6 Gc
1785-ENET 113G PLC-5 ETHERNET INTERFACE MDDULE O' C I +60' C ExnA IIC T5 Gc Communic
1785-KE 113G alion PLC/RS232 INTERFACE MODULE O' C I +60' C Ex nA nC IIC T5 Gc
1785-L20C CONTROLNET PLC5/20, 16K MEMORY, 512 1/0 O'C I +60'C 113G Ex nA IICT4 Gc
113G Processor
1785-L20C15 CONTROLNET PLC5/20, 16K MEMORY, 512 1/0 O°C I +60°C Ex nA IICT4 Gc
Seul le texle en fran~ais peut engager la responsabilile du lCIE. Ce document na paul ~tre reproduil que dans son Inlegralile, sans aucune modification. The LCIE's liability applies only on the French lexl. This document may only be reproduced In its entirety and without any change.
Page 6 sur 11 03A·Annel(o IIU yp_aw_a ... - rev2.DOC
I
13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 AlEX 6020 X I 09 LCIE 01 AlEX 6020 X I 09
Liste des equipements certi fies (suite): Certified equipment list (continuation) :
Catalou I Description Tamb
Marquage I Fonction I Marking Function
1785·L40B ' vV", , R~i~8K WD O°C I +60°C Ex n~l l~cGT4 Gc
1785·L40C l..VN fROLNET 1/0' 48K I ,3072 O°C I +60°C Ex n~II~C';-4 Gc
1785·L40C15 l..UNfROLNET 1/0' 48K I " , 3072 O°C I +60°C Ex n~II~C GT4 Gc Processor
1785·L40E ETHERNET PLC5/40 , 48K MEMORY, 2048 1/0 O°C I +60°C Ex n~II~C';-4 Gc
1785·L80C15 vV",
3072 1/0 O°C I +60°C Exn~ll~cGT4 Gc
1786·RPA CONTROLNET REPEATER HUB ADAPTER O°C I +60°C Ex n~I I~C GT5 Gc
1786·RPCD CONTROLNET HUB REPEATER COPPER O°C I +60°C Exn~ll~cGT5GC Adapler
1786·RPFM FIBER MODULE (MEDIUM RANGE) O°C I +60°C Ex n~\~c GT5 Gc
1786·RPFS vV"" ROLNET FIBEk:~~~~E'~UB "u"c,~" O°C I +60°C Ex n~ll~cc;.5 Gc
1788·CNC CONTROLNET COMMUNICATIONS CARD O°C I +60°C Ex n~ll~cc;.4 Gc
1788·CNCR vV",' ,,0LNET .,~n' ' .. n;~r'" ,v",o; CARD, O°C I +60°C Ex n~ll~cGT4 Gc
1788·CNF vV",' ROLNET FIBg:RD
I "v",,, O°C I +60°C Ex n~ll~cc;.4 Gc Communic
alian
1788·CNFR vV",' ROL~~R~~~~' INnANT I " 'u",,, O°C I +60°C Ex n~II~C GT4 Gc
1788·CN2DN CONTROLNET TO DEVICENET BRIDGE O°C I +60°C Ex n~ll~cGT4 Gc
1794·L33 FLEXLOGIX PROCESSOR 64 K BYTES O°C I +60°C Exn~ll~cGT4 Gc
Ex n~\~c GT5 Gc
Controller 1794·L34 FLEXLOGIX PROCESSOR 512 K BYTES O°C I +60°C
1794·TB2 , I . BASE (34PT) . CAGE CLAMP ·20°C I +55°C Ex n~I I~C GT6 Gc
1794·TB3 , I . BASE (52PT) . CAGE CLAMP ·20°C I + 70°C Ex n~ll~cc;.4 Gc
1794·TB3K I (5~PT .) B.ASe.. II YC:~~T~';;'MP ·20°C I + 70°C Ex n~ll~cGT4 Gc Terminal
1794·TB3S ; CLAMP
·20°C I +70°C Ex n~ll~cGTiQC base (52PT)
1794·TB3G I I . BASE M?5~~i~ CAGE CLAMP GND ·20°C I + 70°C Exn~ll~cGT4 Gc
1794·TB3GK I (52P~~SE MODULE ~e~~ ?~~P GND ·20°C I + 70°C Exn~ll~cGT4 Gc
Seul Ie texle en fra ~als peul engager la responsabillte du l CIE. Ce document ne peut etre reproduit Que dans son integralite, sans aucune modification. The lCIE's liability applies only on the French text. This document may only be reproduced In Its entirely and without any change.
Page 7 sur 11 03A·Annexe IIUyp_app_av - rev2.00C
1---iII 13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite) : Certified equipment list (continuation) :
Reference catalogue Marquage I Fonction I I Description Tamb
Catalog reference Marking Function
1794-TB3GS TERMINAL BASE MODULE SPRING CLAMP
-20'C I + 70'C 113G GND (S2PT) ExnA IIC T4 Gc
1794-TB3GSK TERMINAL BASE MODULE SPRING CLAMP -20' C I + 70' C 113G GND ( S2PTl CONFORMALLY COATED Ex nA IIC T4 Gc
1794-TB3SK TERMINAL BASE MODULE SPRING CLAMP -20'C I + 70'C 113G (S2PT) CONFORMALLY COATED ExnA IIC T4 Gc
1794-TB3T TERMINAL BASE MODULE CAGE CLAMP -20' C I + 70' C 113G (S2PT) TEMPERATURE INPUT Ex nA IIC T4 Gc
TERMINAL BASE MODULE CAGE CLAMP 113G 1794-TB3TK (S2PT) TEMPERATURE INPUT CONFORMALL Y -20'C I +70'C ExnA IIC T4 Gc
Terminal COATED base
1794-TB3TS TERMINAL BASE MODULE SPRING CLAMP -20'C I + 70'C 113G (S2PT) TEMPERATURE INPUT Ex nA IIC T4 Gc
TERMINAL BASE MODULE SPRING CLAMP 113G 1794-TB3TSK (S2PT) TEMPERATURE INPUT. -20' C I + 70' C
Ex nA IIC T4 Gc CONFORMALLY COATED
1794-TBN TERMINAL BASE MODULE NEMA CLAMP GND -20'C I + 70'C 113G (20PT) Ex nA IICT4 Gc
1794-TBNK TERMINAL BASE MODULE NEMA CLAMP GND -20' C I +70' C 113G
(20PT) CONFORMALLY COATED Ex nA IICT4 Gc
1794-ACN 24VDC CONTROLNET ADAPTER O' C I +SS'C 113G ExnA IICT4 Gc
1794-ACN1S CONTROLNET TO FLEX ADAPTER O'C I +SS' C 113G
Ex nA IIC T4 Gc
1794-ACN1SK CONTROL NET TO FLEX ADAPTER O' C I +SS' C 113G CONFORMALLY COATED ExnA IICT4 Gc
1794-ACNR DUAL MEDIA CONTROLNET ADAPTER O'C I +SS' C 113G
Ex nA IIC T4 Gc
1794-ACNR1S CONTROL NET REDUNDANT MEDIA ADAPTER O' C I +SS' C 113G Ex nA IIC T4 Gc
1794-ACNR1SK CONTROLNET REDUNDANT MEDIA ADAPTER -20' C I +SS' C 113G CONFORMALLY COATED Ex nAIICT4Gc
1794-ACNR1SXT CONTROL NET REDUNDANT MEDIA ADAPTER -20' C I + 70'C 113G Adapter
EXTENDED TEMPERATURE ExnA IIC T4 Gc
1794-ADN DEVICENET ADAPTER -20' C I + 70'C 113G Ex nA IIC T4 Gc
1794-ADNK DEVICE NET ADAPTER CONFORMALL Y -20'C I + 70' C 113G COATED Ex nA IIC T4 Gc
1794-ASB 24 VDC RIO ADAPTER -20' C I +SS' C 113G ExnAIICT4Gc
1794-ASB2 24 VDC RIO ADAPTER -20' C I +SS' C 113G Ex nA IIC T4 Gc
1794-ASBK 24 VDC RIO ADAPTER CONFORMALL Y -20' C I +SS' C
113G COATED ExnA IICT4 Gc
1794-FLA FLEXLOGIX FLEXBUS ADAPTER O' C I +60' C 113G Ex nA IIC T6 Gc
1794-IA8K 120VAC INPUT (8PT) CONFORMALLY -20' C I +SS' C 113G Input COATED Ex nA IIC T4 Gc module
Seul Ie texte en franc;als peut engager la responsabilite du lCIE. Ce document ne peut ette reproduil que dans son integralile , sans aucune modification. The lCIE's liability applies only on the French text. This document may only be reproduced in its entirety and without any change.
Page 8 sur 11 03A-AnnsKs 1II_lyp_app_a ... - rsa.DOC
1---iI 13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipements certifies (suite): Certified equipment lisl (conlinualion) :
Reference catalogue Marquage I Fonction I I Description Tamb
Catalog reference Marking Function
1794·IB10XOB6 24VDC COMBINATION 10 INPUT, 6 OUTPUT ·20·C / +SS·C 113G
Ex nA IIC T3 Gc
1794· IB10XOB6XT 24VDC COMBINATION 10 INPUT, 6 OUTPUT,
·20· C / +70· C 113G EXTENDED TEMPERATURE ExnA IICT3 Gc
1794·IB8 24VDC 16 CHANNEL SINKING OUTPUT
O·C / +SS·C 113G
MODULE ExnA IICT3 Gc
1794·IB8S SENSOR INPUT (8PT) O· C / +SS· C 113G Ex nA IIC T4 Gc
1794·IB16 24VDC SINK INPUT, 16 PT ·20·C / +SS·C 113G
Ex nA IIC T4 Gc
1794·IB16K 24VDC SINK INPUT, 16 PT CONFORMALL Y
·20·C / +SS·C 113G
COATED ExnAIICT4Gc
1794·IB16XT 24VDC SINK INPUT, 16 PT, EXTENDED
·20·C / +70· C 113G
TEMPERATURE ExnA IIC T4 Gc
1794·IC16 48Vdc SINK INPUT MODULE (16 PT) O·C / +SS·C 113G Ex nA IIC T3 Gc
1794·IE4XOE2 ANALOG COMMUNICATION MODULE 12 BIT 4
·20·C / +SS·C 113G
INPUT/2 OUTPUT ExnAIICT4Gc ANALOG COMMUNICATION MODULE 12 BIT 4
113G 1794·IE4XOE2XT INPUT/2 OUTPUT, EXTENDED ·20·C / +70· C
TEMPERATURE ExnAIICT4Gc
1794·IE8 ANALOG INPUT (8 PT ) ·20·C / +SS·C 113G
Ex nA IIC TS Gc
1794·IE8K ANALOG INPUT (8 PT ) CONFORMALL Y
·20·C / +SS· C 113G
COATED ExnA IIC TS Gc ANALOG INPUT (8 PT), EXTENDED 113G
Input 1794· IE8XT
TEMPERATURE ·20· C / + 70· C
Ex nA IIC TS Gc module
1794· IF2XOF21 ISOLATED ANALOG COMBINATION (2 INPUT/2
·20· C / +SS· C 113G
OUTPUT) Ex nA IIC T4 Gc
1794· IF2XOF21XT ISOLATED ANALOG COMBINATION (2 INPUT/2
·20·C / +70· C 113G
OUTPUT) EXTENDED TEMPERATURE Ex nA IIC T4 Gc
1794·IF41 ISOLATED ANALOG INPUT (4PT) ·20· C / +SS·C 113G Ex nA IIC T4 Gc
1794·IF41XT ISOLATED ANALOG INPUT (4PT), EXTENDED
·20· C / + 70· C 113G
TEMPERATURE ExnA IIC T4 Gc
1794·IF4ICFXT ISOLATED ANALOG INPUT, EXTENDED
·20· C / + 70· C 113G
TEMPERATURE, 4 PT Ex nA IIC T4 Gc
1794·IJ2 2 CHANNEL FREQUENCY INPUT, 2 DIGITAL
·20·C / +SS·C 113G
OUTPUT ExnA IIC T4 Gc
1794·IJ2K 2 CHANNEL FREQUENCY INPUT, 2 DIGITAL
·20·C / +SS· C 11 3 G
OUTPUT, CONFORMALLY COATED ExnA IIC T4 Gc
1794·IJ2XT 2 CHANNEL FREQUENCY INPUT, 2 DIGITAL
·20· C / + 70·C 113G
OUTPUT, EXTENDED TEMPERATURE ExnA IICT4 Gc
1794·IR8 RTD INPUT MODULE (8 PT) ·20· C / +SS· C 113G
ExnA IIC T4 Gc
1794· IRT8 THERMOCOUPLE & RTD MODULE (8 PT) ·20· C / +SS· C 113G
ExnA IICT4 Gc
1794·IRT8K THERMOCOUPLE & RTD ~~!DULE, ·20·C / +SS·C 113G
CONFORMALLY COATED 8 PT) Ex nA IIC T4 Gc
1794·IRT8XT THERMOCOUPLE & RTD MODULE (8 PT),
·20·C / + 70· C 113G EXTENDED TEMPERATURE ExnA IICT4 Gc
Seul le texte en fran(j:ais peut engager la responsabilite du lCIE. Ce document ne peut el{e rep{oduil que dans son integ{alite, sans aucune modification. The lCIE's liability applies only on the French text. This document may only be reproduced In its entirety and without any change.
P3go 9sur11 03A·Annexa IIUyp_app_3v - rev2.DOC
I
1 __ -.
13 ANNEXE (Suite) 13 SCHEDULE (Continued)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 X I 09 LCIE 01 ATEX 6020 X I 09
Liste des equipemenls certifies (suite) : Certified equipmenllist (continua lion) :
Reference catalogue Marquage I Fonction I I Description Tamb
Cataloa reference Marking Function
1794·IT8 THERMOCOUPLE INPUT (8 PT) ·20°C I +55°C 113G ExnA IIC T4 Gc
1794·IT8XT THERMOCOUPLE INPUT (8 PT), , EXTENDED ·20°C I + 70°C 113G Input
TEMPERATURE Ex nA IIC T4 Gc module
1794·IV16 FLEX 1/0 24VDC(16 PT) O°C I +55°C 113G Ex nA IIC T3 Gc
1794·0A8K 8PT 120VAC OUTPUT, CONFORMALL Y ·20°C I +55°C
113G COATED Ex nA IIC T4 Gc
1794·0B8 FLEX 1/0 24VDC 16·CHANNEL OUTPUT ·20°C I +55°C 113G Ex nA IIC T4 Gc
1794·0B8EP FLEX 1/0 24VDC 8 CHANNEL 24A, SHORT
·20°C I +55°C 113G
PROOF OUTPUT ExnA IIC T4 Gc
1794·088EPK FLEX 1/0 24VDC 8 CHANNEL 24A, SHORT ·20°C I +55°C 113G
PROOF OUTPUT, CONFORMALL Y COATED Ex nA IIC T4 Gc
1794·0B8EPXT FLEX 1/0 24VDC 8 CHANNEL 24A, SHORT
·20°C I + 70°C 113G
PROOF OUTPUT, EXTENDED TEMPERATURE Ex nA IIC T4 Gc
1794·0816 24V DC SOURCE 16·CHANNEL OUTPUT ·20°C I +55°C 113G
Ex nA IIC T4 Gc
1794·0B16P 24V DC SOURCE OUTPUT ·20°C I +55°C 113G
ExnA IIC T3Gc
1794·0816PK 24V DC SOURCE OUTPUT MODULE, ·20°C I +55°C
113G CONFORMALL Y COATED Ex nA IIC T3 Gc
1794·0B16PXT 24V DC SOURCE OUTPUT, EXTENDED ·20°C I + 70°C 113G
TEMPERATURE ExnA IIC T3Gc
1794·0C16 16 SOURCE OUTPUT ·20°C I +55°C 113G
Ex nA IIC T4 Gc Oulput
1794·0E4 4PT ANALOG OUTPUT ·20°C I +55°C 113G module ExnA IICT4 Gc
1794·0E4K 4PT ANALOG OUTPUT CONFORMALL Y ·20°C I +55°C 113G
COATED Ex nA IIC T4 Gc
1794·0E4XT 4PT ANALOG OUTPUT, EXTENDED
·20°C I + 70°C 113G
TEMPERATURE ExnA IICT4 Gc
1794·0F41 4PT ISOLATED ANALOG OUTPUT ·20°C I +55°C 113G Ex nA IIC T4 Gc
1794·0F4IXT 4PT ISOLATED ANALOG OUTPUT, EXTENDED ·20°C I + 70°C
113G TEMPERATURE ExnA IICT4 Gc
1794·0V16 FLEX 1/0 24VDC 16·CHANNEL aoc I +55°C 113G Ex nA IIC T4 Gc
1794·0V16P 24VOC SINK OUTPUT MODULE O°C I +55°C 113G ExnA IIC T4 Gc
1794·0W8 ISOLATED RELAY OUTPUT MODULE, 8PT ·20°C I +55°C 113G
Ex nA nC IIC T5 Gc
1794·0W8K ISOLATED RELAY OUTPUT MODULE, 8PT, ·20°C I +55°C
113G CONFORMALLY COATED Ex nA nC IIC T5 Gc
1794·0W8XT ISOLATED RELAY OUTPUT MODULE, 8PT, ·20°C I + 70°C 113G
EXTENDED TEMPERATURE Ex nA nC IIC T5 Gc
Seulle texle en fran(fsis peul engager la responssbmt~ du l CIE. Ce document ne peut eIre reproduil que dans son integralite, sans aucune modification. The LCIE's liability applies only on the French texl. This document may only be reproduced In lis entirely and without any change.
Page 10 sur 11 03A·Annexa IIUyp_app~av - rav2.DOC
a __ M*
13 ANNEXE (Suite)
14 AVENANT D'ATTESTATION D'EXAMEN DE TYPE
LCIE 01 ATEX 6020 XI 09
Les resultats des verifications et essais figurent dans Ie rapport confidentiel W 106905·612164·01 .
Parametres specifigues du ou des modes de protection concerne(s) : Inchanges.
Le marguage doit etre : Rockwell Automation Inc. ou marque commerciale Adresse: ... Type: ... Annee de fabrication 1 N' de fabrication GII3G Ex nA ou nA nC IIC T6 a T3 Gc (selon modele: voir tableau) LCIE 01 ATEX 6020 X
Quand des batteries sont utilisees, les informations suivantes doivent etre indiquees :
Le type de construction des elements Le nombre d'elements et la tension nominale La capacite assignee avec la duree de decharge correspondante
16 DOCUMENTS DESCRIPTIFS Dossier de certification n' 1192·K rev. 10 du 27109/2011.
17 CONDITIONS SPECIALES POUR UNE UTILISATION SORE Gamme de temperature ambiante d'utilisation : voir tableau . Tous les automates doivent etre places a I'interieur d'une enveloppe assurant la protection mecanique et un degre de protection au moins egal a IP54 conformement a la norme EN 60079·15 (2010). Tous les automates devront etre utilises selon les caracteristiques definies par Ie constructeur.
18 EXIGENCES ESSENTIELLES DE SECURITE ET DE SANTE Couvertes par les normes EN 60079·0 (2009) et EN 60079·15 (2010).
19 VERIFICATIONS ET ESSAIS INDIVIDUELS Essai de ri9id ite dielectrique selon la norme EN 60079·15 (2010) § 23.2.1.
13 SCHEDULE (Continued)
14 SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
LCIE 01 ATEX 6020 XI 09
The examination and test resulls are recorded in confidential report N' 106905·612164·01.
Specific parameters of the mode's) of protection concerned: Unchanged.
The marking shall be : Rockwell Automation Inc. or trademark Address: ... Type: ... Year of fabrication 1 N' of fabrication GI13G Ex nA or nA nC IIC T6 to T3 Gc (according to model: see table) LCIE 01 ATEX 6020 X
When batteries are used, the following information shall be marked:
The type of construction of cells Number of cells and nominal vollage Rated capacity with the corresponding duration of discharge
16 DESCRIPTIVE DOCUMENTS Certification file n' 1192·K rev. 10 dated 2011/09/27.
17 SPECIAL CONDITIONS FOR SAFE USE
Ambient operating temperature range: see table.
All PLCs shall be placed into an enclosure which ensures the mechanical protection and a minimum degree of protection IP54 as required by the standard EN 60079·15 (2010). All PLCs shall be used within their specified ratings defined by the manufacturer.
18 ESSENTIAL HEALTH AND SAFETY REQUIREMENTS
Covered by standards EN 60079·0 (2009) and EN 60079·15 (2010).
19 ROUTINE VERIFICATIONS AND TESTS Dielectric strength test according to the standard EN 60079·15 (2010 23.2.1.