DESCRIPTION

Measurements in Fluid Mechanics 058:180:001 (ME:5180:0001) Time & Location: 2:30P - 3:20P MWF 218 MLH Office Hours: 4:00P – 5:00P MWF 223B-5 HL. Instructor: Lichuan Gui lichuan-gui@uiowa.edu http:// lcgui.net. Lecture 14. Flow rate measurement. Flow rate measurement. V n. Bulk flow rate. - PowerPoint PPT Presentation

TRANSCRIPT

Measurements in Fluid Mechanics058:180:001 (ME:5180:0001)

Time & Location: 2:30P - 3:20P MWF 218 MLH

Office Hours: 4:00P – 5:00P MWF 223B-5 HL

Instructor: Lichuan Guilichuan-gui@uiowa.edu

http://lcgui.net

2

Lecture 14. Flow rate measurement

3

Bulk flow rate

Flow rate measurement

- the amount of fluid that pass through a certain cross section of a pipe, duct, channel, or other conduit per unite time.

Mass flow rate

Direct methods for flow rate measurement

A

Vn - measure typical flow velocity, i.e.

𝑄=𝑉 ∙ 𝐴𝑜𝑟𝑄=∫𝐴

𝑉 𝑛𝑑 𝐴

- measure amount of discharged fluid over a period of time, i.e.

�̇�=𝑚∆ 𝑡

𝑜𝑟 𝑄=𝐶∆ 𝑡 C – volume of fluid

- positive-displacement flow meters

Volume flow rate Q – usually used for liquids or low-speed gasses

- not concerned with local velocity variations across cross-section

- not concerned with short-time (turbulent) fluctuations

4

Flow rate measurement

Positive-displacement (PD) flow meters

- volume flow rate calculated from the size and number of compartments and the repetition rate

- some PD meters may passively receive power from flowing fluid to operate.

- devices that isolate fixed volumes of fluid flowing into their inlet in sealed compartments and then discharge them to the outlet.

- a great variety of designs of PD meters, classified as rotary, reciprocating, or nutating

- some PD meters (metering pumps) are driven by external power source to create fluid motion.

- problems of PD flow meters: leakage and pressure loss

- PD meters for liquidsNutating disk meters, reciprocating-piston meters, rotary-piston meters, rotary-vane meters, rotor meters

- PD meters for gases

Roots-type meters, diaphragm-type meters, liquid-sealed drum-type meters

5

Flow rate measurement

Nutating disk meters

- a disk rotating in a nutating fashion in a dual conical housing

6

Flow rate measurement

single piston reciprocating

Reciprocating -piston meters

- plunger or piston driven by wobble plate (or cam)

77

Flow rate measurement

Rotary-piston (oscillating piston ) flow meters

- a cylindrical drum mounted eccentrically inside a cylindrical housing

88

Flow rate measurement

Rotary-vane flow meters

- flat vanes inserted into matching slots around the perimeter of a cylindrical drum located eccentrically within the housing

9

Flow rate measurement

Rotor meters

Oval Gear Meters

10

Flow rate measurement

Rotor meters

Gear flow meters

11

Helical gear flow meter

Flow rate measurement

Rotor meters

12

Flow rate measurement

Roots-type flow meters

- a particular design of a lobe meter

Lobe Rotary Piston

Flow rate measurement

Diaphragm-type meters

13

14

Flow rate measurement

Liquid-sealed flow meters

- wet gas meters: liquid provides sealing action

Liquid ring pump

15

Flow rate measurement

Restriction (or obstruction) flow meters

Venturi tubes (a & b) Flow nozzles (d) Dall tubes (c) Orifice-plate (e)

𝑑𝐷

∆ 𝑝

- Circular tube of diameter D

- Smaller diameter d in restriction to increase velocity & result in pressure drop

- Ideal volume rate determined by continuity & Bernoulli’s equation :

- Measured volume rate with empirical discharge coefficient :

16

Flow rate measurement

Open-channel flow measurement

- Weirs of sharp crested and broad crested with rectangular, v-shaped or trapezoidal openings

- Flow rate over weirs:

Weirs

Venturi flumes

- converging-diverging channel constructions

17

Homework

- Questions and Problems: 1 on page 219- Read textbook 9.1-9.4 on page 208 - 212

- Due on 09/30