LOW VOLTAGE ELECTRICAL COMPONENTS
LOW VOLTAGE ELECTRICAL COMPONENTS
MINIATURE CIRCUIT BREAKER 3
MCB ISOLATOR
ELCB / RCCB
DISTRIBUTION SYSTEM
CONTENTS PAGE
FLUORESCENT LUMINAّّIRES
10
13
17
20
1
T h e d i f f e r e n c e i s . . . . . . t o p e r c e i v e , c r e a t e & s w i f t l y d e l i v e r
I n t u i t i o n . . . I n n o v a t i o n . . . A g i l i t y . . .
The GROUP HARWAL’s primary business is based on plastic & metal products, with over 60 years of experience in different processes and technologies. Plastic Compounds, Building Materials, Pipe Line Systems, Housing Systems, Shelters, Electrical Products, Household Items, Storage Containers, Garden Sheds, Plastic Disposables, Packaging Materials, Outdoor Products, Refrigeration, Residential & Contract Furniture are just some of the products manufactured by HARWAL under our wide spread manufacturing facilities in UAE, USA & CIS countries.
With an annual conversion capacity of 200,000 metric tons of plastic and 20,000 tons of aluminium & steel, the Group has come to the forefront of their respective industries.
INTERPLAST COMPANY LIMITEDMember of Group Harwal
Interplast Co. Ltd, a member of Group Harwal was established in 1981 to manufacture PVC
compounds for the GCC market’s. GROUP HARWAL’S technological capabilities assisted
INTERPLAST in rapidly becoming a leading manufacturer of PVC compounds, marketed
under the trade name of IP-HARWAL. In 1984 INTERPLAST diversified into the extrusion of
DECODUCT Conduits and Trunkings for Electrical & Cable Management applications. This
downstream operation was further strengthened in 1987 with introduction of DECODUCT
injection moulding for PVC conduit & trunking fittings.
Over the years INTERPLAST electrical products have gained the confidence and
appreciation of its customers spread over GCC,AFRICA,ASIA and European Regions. To
satisfy the ever-increasing demand of its products, INTERPLAST expanded into new and
spacious factory premises in October 1988. In 1997 INTERPLAST launched the complete
range of EDISON wiring accessories & over the years this range is expanded into one of the
widest range of switches and sockets manufactured in UAE.
INTERPLAST is introducing DECOVOLT range of low voltage switchgears comprising of
Miniature Circuit Breakers, MCB ISOLATORS, ELCB’s, MCB Distribution System &
Fluorescent fixtures. DECOVOLT range is OEM manufactured as per international standards
IEC/EN 60947-3 & 60898, where as the quality management system is certified to
ISO9001 by ASTA U.K. DECOVOLT Products are CE marked declaring conformity to
European standards and safety regulations.
2
Electrical distribution needs are continuously evolving in residentional, commercial andIndustrial sectors. Improved operational safety, continuity of service, greater convenience and operating cost have assumed a tremendous significance. Miniature circuit breakers have been designed to continuously adapt to these changing needs.
Range6A to 40A "B" Curve0.5A to 63A "C" Curve0.5A to 63A for "DC" Application
ExecutionSingle Pole (1P)Single Pole & Neutral (1P+N)Double Pole (2P)Three Pole (3P)Three Pole & Neutral (3P+N)Four Pole (4P)
SpecificationIEC/EN 60898
Feature • Precise hammer action• 15 Plates Arc Chute for effective arc quenching• Longer electrical life• Wide range• Value for money• Low power consumption, thus cost effective & energy saving
AccessoriesAuxiliary SwitchShunt trip
• UNIFORM 10KA BREAKING CAPACITY FOR "B" AND "C" CURVE
• LOW POWER CONSUMPTION, THUS COST EFFECTIVE & ENERGY SAVING
• SUITABLE FOR DC AND FOR A WIDE FREQUENCY RANGE OF 50Hz-400Hz APPLICATION
• "FINGER SAFE" TERMINALS-IP20 DEGREE OF PROTECTION
• ARC CHUTE FOR EFFECTIVE ARC QUENCHING
• SILVER GRAPHITE CONTACTS FOR ENHANCED LIFE
MINIATURE CIRCUIT BREAKER
3
HOUSING:• The housing of Decovolt MCB is Injection Moulded from special grade PBT as per international specifications.• The housing and other moulded components are fire retardant, anti-tracking and non hygroscopic.• The Housing can withstand high temperature and is impact resistant.
CONTACTS:Contacts are made of special silver inlaid into copper strip, ensuring higher life and maximum safety against contact welding and erosion. These contacts have low contact resistance resulting into low watt loss.
CURRENT LIMITING ACTION: The high speed current limiting action ensures that the MCB operate before the full prospective fault current is allowed to develop. Under fault conditions, damage can be sustained to the installation and associated equipment due to the amount of energy that passes before the current is completely interrupted. The total energy let through depends on the value of current and the time for which it flows. The high speed current limiting action of DECOVOLT MCB ensures that the energy let through and any subsequent damage is minimized. This reduced LET THROUGH ENERGY (Class 3 as per BSEN 60898) assists greatly with both back-up and discrimination considerations.
OPERATING MECHANISM: DECOVOLT MCB have a quick make and break trip free mechanism. In the event of an over current or short circuit the MCB automatically interrupts all poles even if the MCB toggle is held in ON position, the handle always indicates the correct contact position.
MODERATE OVERLOAD CONDITION: Detection of moderate Over load conditions is achieved by the use of a Bimetal Overload Relay, which deflects in response to the current passing through it The Bimetal Relay moves against the trip bar releasing the trip mechanism.
SHORT CIRCUIT CONDITIONS: When the current flowing through the MCB reaches a predeter-mined level, the solenoid in Magnetic coil directly pulls in the plunger, which releases the trip mechanism.
PERFECT CONECTIONS: The design of termi-nals makes the wiring easier. A combination box type terminal with combination head screws on both sides with deep serrations ensures sparkles and firm connections.
Outgoing Terminal
Body
Latch
Arc-chutes Holder
Solenoid
Arc-chutes
Arc-runner
Arc-chutes Holder
Fixed Contact
Moving Contact Arm
Incoming Terminal(Dual Termination)
MINIATURE CIRCUIT BREAKER
Internal View of MCB
4
MINIATURE CIRCUIT BREAKER
TECHNICAL INFORMATION
STANDARD CONFORMITY IEC 60898:2002 IEC 60947-3:2001TYPE/SERIES CB B
Nos of Poles (Execution)RATED SHORT CIRCUITBREAKING CAPACITY Ka
1P,1P+N,2P,3P,3P+N,4P1P,1P+N,2P,3P,3P+N,4P 1P,1P+N,2P,3P,3P+N,4P
UTILIZATION CATEGORY
(3-5) InMAGNETIC RELEASESETTING (3-5) In (3-5) In
660RATED INSULATIONVOLTAGE(Ui) 660 660
4RATED IMPULSEVOLTAGE (Uimp)ELECTRICAL / MECHANICALENDURANCE
4 4
RATED FREQUENCY (f) 5050 50
1010 10
RATED VOLTAGE (AC) (Ue) 240/415240/415 240/415RATED CURRENT (In) 6-40*6-40* 6-40*
LESS THAN 32 Amps 2000020000 20000MORE THAN 32 Amps 1000010000 10000AMBIENT TEMPERATURE - 5 to + 55- 5 to + 55 - 5 to + 55
VIBERATION g 33 3SHOCK 40MM FREE FALL40MM FREE FALL 40MM FREE FALLPROTECTION CLASS IP 20IP 20 IP 20INSTALLATION POSITION VERTICAL/ HORIZONTALVERTICAL/ HORIZONTAL VERTICAL/ HORIZONTALMOUNTING CLIP ON DIN RAILCLIP ON DIN RAIL CLIP ON DIN RAILCASE & COVER MOULDED, FLAME RETARDANT THERMOPLASTIC MATERIAL
TERMINAL CAPACITY(MAX) sq.mm 2525 25
MCB ISOLATORTITLE
1P SINGLE POLE1P+N SINGLE POLE NEUTRAL2P DOUBLE POLE3P THREE POLE3P+N THREE POLE NEUTRAL4P FOUR POLE
*** CURRENT RATINGS - 0.5, 1,2,3,4,5,6,8,10,16,20,25,32,40,50,63"B" CURVE MCB's ARE AVAILABLE ON REQUEST
5
MINIATURE CIRCUIT BREAKER
SELECTION
SELECTION OF MCB FOR MOTOR PROTECTION
S.NO KW HP
3017 51- 51 63125-38- 38 63125-32- 32 50125-27- 27 4063100-21- 21 325050-
14.4125 14.4 2540404711.280 11.2 163225268.280 8.2 102020246.363 6.3 101616204.450 - --1017.53.532 - --1011.82.625 - --68.7220 - --36.2
1.816 - --34.81.210 - --23.51.210 - --23.20.910 - --22.8
C DCC
221618.515151410137.5125.5113.7510
392.281.571.16
1.011.472.012.954.025.037.3710.0513.420.1124.829.4940.21
0.7550.740.5540.50.3730.340.2520.240.181
FULL LOADCURRENT
FULL LOADCURRENT
3 PHASE 400V ASSISTEDSTARTING STAR DELTA
"B" SERIES"B" SERIES
"B" SERIES"B" SERIES
"C" SERIES"C" SERIES
TYPE OFMCB
LampWatt
No oflamps
Rating(A)
20W 812
11.5
40W 21012
0.52
2.5
100W 124
11.52.5
60W 148
12
0.51.534
80W 1258
12
0.51245
CURRENTRATING OF MCB
CAPACITY/WATT(Load)(240V-1pH)APPLIANCES
Fresh hold application
"B" SERIES"B" SERIES
"B" SERIES"B" SERIES"B" SERIES"B" SERIES
"B" SERIES"B" SERIES"B" SERIES"B" SERIES"C" SERIES
"C" SERIES
WASHING MACHINEWASHING MACHINEWITH HEATER
"C" SERIES"C" SERIES"C" SERIES
8A10A
32A10A
3A4A
6A8A
6A10A16A32A
6A10A6A10A2A
8A
10A16A20A
1200W1500W
4500 W1750 W
165 litres350 litres
750W1250W
1000W2000W3000W6000W
AUTO TOASTER ( 2 SLICES)ELECTRIC KETTLE
" B " series MCB is used forlighting applications
ELECTRIC IRON
WATER HEATERSTORAGE / INSTANT
750W2000W1000W2000W300W
1300W
1.0 tonnes1.5 tonnes2.0 tonnes
OVEN/GRILLER
REFRIGATOR
OVEN/GRILLERHOT PLATE ONLYROOM HEATER
AIR CONDITIONER
MCBSELECTION
MCBSELECTION
1 PHASE 230V DOLSTARTING
FULL LOADCURRENT
MCBSELECTION
3 PHASE 400V DOLSTARTING
NOTE: One lighting circuit can have up to 800W or up to 10 lighting pointsOne power circuit can have up to 2000W or 1 power point
6
1000050003600
1000
100
10
11.131.45 2 2.55 3 5 10 14 20 28 50
1
0.1
0.01
Tim
e in
Sec
onds
Multiple of Rated Current
Limit Specified in IEC-60898-1-2002In : Rated Current B Type - 0.5A to 100A C Type - 0.5A to 100A
Reference Calibration Temp-30˚C
Lower Limit as per Standard
In > 32A
In < 32A
B-Type C-Type
Upper Limit as per Standard
1000050003600
1000
100
10
11.131.45 2 2.55 3 5 10 14 20 28 50
1
0.1
0.01
Tim
e in
Sec
onds
Multiple of Rated Current
Limit Specified inIEC-60898-1-2002In : Rated CurrentB Type - 0.5A to 100AC Type - 0.5A to 100A
Reference Calibration Temp-30˚C
Lower Limit as per Standard
In > 32A
In < 32A
B-Type
C-Type
Upper Limit as per Standard
60
CurrentLimiting
MCB
Zero pointExtinguishingMCB
Un = Mains VoltageID = Let - through short circuit current
UB = Arc VoltageIp = Prospective short circuit current
U/V
U/V
U/V
50
40
30
20
10
0.7 0.6 0.9 1.0 1.1 1.2 1.3 1.4
-10
0
Correction FactorReference Calibration Temp. 30˚C
Am
bien
t Tem
p.˚C
Temperature Compensation GraphDecovolt MCB Vs Zero Point
Extinguishing MCB
Tripping Characterstics CurveDC MCB Type B & C
Tripping Characterstics CurveType B & C
TRIPPING CHARACTERSTICS CURVES
MINIATURE CIRCUIT BREAKER
7
CURRENT RATING (A)0.5123456
1016202532405063
CURRENT RATING (A)0.5123456
1016202532405063
CURRENT RATING (A)0.5123456
1016202532405063
"B CURVE" CAT NODVBDP105
DVBDP1001DVBDP1002DVBDP1003DVBDP1004DVBDP1005DVBDP1006DVBDP1010DVBDP1016DVBDP1020DVBDP1025DVBDP1032DVBDP1040DVBDP1050DVBDP1063
"C" CURVE CAT NODVCDP105
DVCDP1001DVCDP1002DVCDP1003DVCDP1004DVCDP1005DVCDP1006DVCDP1010DVCDP1016DVCDP1020DVCDP1025DVCDP1032DVCDP1040DVCDP1050DVCDP1063
"C" CURVE CAT NODVASP105
DVASP1001DVASP1002DVASP1003DVASP1004DVASP1005DVASP1006DVASP1010DVASP1016DVASP1020DVASP1025DVASP1032DVASP1040DVASP1050DVASP1063
"B CURVE" CAT NODVBSP105
DVBSP1001DVBSP1002DVBSP1003DVBSP1004DVBSP1005DVBSP1006DVBSP1010DVBSP1016DVBSP1020DVBSP1025DVBSP1032DVBSP1040DVBSP1050DVBSP1063
"C" CURVE CAT NODVCSP105
DVCSP1001DVCSP1002DVCSP1003DVCSP1004DVCSP1005DVCSP1006DVCSP1010DVCSP1016DVCSP1020DVCSP1025DVCSP1032DVCSP1040DVCSP1050DVCSP1063
SINGLE POLE
SINGLE POLE - N
DOUBLE POLE
MINIATURE CIRCUIT BREAKER
8
CURRENT RATING (A)0.5123456
1016202532405063
CURRENT RATING (A)0.5123456
1016202532405063
CURRENT RATING (A)0.5123456
1016202532405063
"B CURVE" CAT NODVBFP105
DVBFP1001DVBFP1002DVBFP1003DVBFP1004DVBFP1005DVBFP1006DVBFP1010DVBFP1016DVBFP1020DVBFP1025DVBFP1032DVBFP1040DVBFP1050DVBFP1063
"C" CURVE CAT NODVCFP105
DVCFP1001DVCFP1002DVCFP1003DVCFP1004DVCFP1005DVCFP1006DVCFP1010DVCFP1016DVCFP1020DVCFP1025DVCFP1032DVCFP1040DVCFP1050DVCFP1063
"C" CURVE CAT NODVATP105
DVATP1001DVATP1002DVATP1003DVATP1004DVATP1005DVATP1006DVATP1010DVATP1016DVATP1020DVATP1025DVATP1032DVATP1040DVATP1050DVATP1063
"B CURVE" CAT NODVBTP105
DVBTP1001DVBTP1002DVBTP1003DVBTP1004DVBTP1005DVBTP1006DVBTP1010DVBTP1016DVBTP1020DVBTP1025DVBTP1032DVBTP1040DVBTP1050DVBTP1063
"C" CURVE CAT NODVCTP105
DVCTP1001DVCTP1002DVCTP1003DVCTP1004DVCTP1005DVCTP1006DVCTP1010DVCTP1016DVCTP1020DVCTP1025DVCTP1032DVCTP1040DVCTP1050DVCTP1063
THREEE POLE
THREEE POLE - N
DOUBLE POLE
MINIATURE CIRCUIT BREAKER
9
They are switch disconnectors with independentmanual operation, capable of making, carryingand breaking currents under normal circuit conditions , which may include operating overloadcondition and also carry currents under specified abnormal circuit conditions such as those of short circuit for a specified time.
Range
40A, 63A , 80A , 100A
ExecutionSingle Pole (1P)Double Pole (2P)Three Pole (3P)Four Pole (4P)
SpecificationIEC 60947-3
Feature • low watt loss• longer electrical life• Wide Range• Value for Money• Low power consumption• Cost effective and energy saving
• CONFORMING TO IEC - 60947 - 3
• LOW POWER CONSUMPTION, THUS COST EFFECTIVE & ENERGY SAVING
• LOW WATT LOSS
• COST AND ENERGY SAVING
DECOVOLT ISOLATOR
10
CURRENT RATING (A)25406380
100
CURRENT RATING (A)25406380
100
CURRENT RATING (A)25406380
100
CAT NODVISODP25DVISODP40DVISODP63DVISODP80
DVISODP100
CAT NODVISODP25DVISODP40DVISODP63DVISODP80
DVISODP100
CAT NODVISODP25DVISODP40DVISODP63DVISODP80
DVISODP100
DOUBLE POLE
THREE POLE
FOUR POLE
DECOVOLT ISOLATOR
11
BC
D
EA
35.0
70.5
64.0
DECOVOLT ISOLATOR
TECHNICAL INFORMATIONSTANDARD CONFORMITY IEC 60947-3:2001TYPE/SERIES B
Nos of Poles (Execution) 1P,1P+N,2P,3P,3P+N,4PRATED SHORT CIRCUIT BREAKING CAPACITY Ka 10UTILIZATION CATEGORYMAGNETIC RELEASE SETTING (3-5) InRATED INSULATION VOLTAGE(Ui) 660RATED IMPULSE VOLTAGE (Uimp) 4ELECTRICAL / MECHANICAL ENDURANCE 10000AMBIENT TEMPERATURE - 5 to + 55TERMINAL CAPACITY (MAX) sq.mm 25VIBERATION g 5SHOCK 40mm FREE FALLPROTECTION CLASS IP 20INSTALLATION POSITION VERTICAL/ HORIZONTALMOUNTING CLIP ON DIN RAILCASE & COVER MOULDED REINFORCED PLASTIC
RATED FREQUENCY (f) 50RATED VOLTAGE (AC) (Ue) 240/415RATED CURRENT (In) 6-40*
A CBDP
3617.5
A70
72.770
SP SPN FP
71.5
TP TPN80
53.510626.6
ED
60 454460 454460 4544
MCB'SISOLATORSAUXILIARY CONTACT
12
The flow of current through electrical facilitiesalways involves risks. Poorly insulated equipment,faulty wires and incorrect use of an electrical device cause currents to flow through the wrongpath (i.e through the insulation) to the earth.This current is called "leakage current".
Earth leakage is an electrical hazard and is responsible for electrical shocks and fire risks. Earth leakage and its associated hazard can be prevented by residual current circuit breaker (RCCB), also popularly known as ELCB
Range
25A-63A
Sensitivity
30mA , 100mA, 300mA
ExecutionDouble Pole (2P)Four Pole (4P)
SpecificationIEC 61008-1 / EN 61008-1
Feature • Simple and Robust operating mechanism• Rotary handle with ON/OFF Indication• Dual termination for Bus Bar as well as cable Connection• Advance neutral• Test Button for regular Inspection• Positive contact indication
• IEC 61008-1 / EN 61008-1
• LOW POWER CONSUMPTION, THUS COST EFFECTIVE & ENERGY SAVING
• TEST BUTTON FOR REGULAR INSPECTION
• COST EFFECTIVE AND ENERGY SAVING
DECOVOLT RCCB
13
CURRENT RATING (A)252525323232404040636363
CURRENT RATING (A)252525323232404040636363
SENSITIVITY (mA)30
10030030
10030030
10030030
100300
CAT NODVELFP25030
DVELFP250100DVELFP250300DVELFP32030
DVELFP320100DVELFP320300DVELFP40030
DVELFP400100DVELFP400300DVELFP63030
DVELFP630100DVELFP630300
SENSITIVITY (mA)30
10030030
10030030
10030030
100300
CAT NODVELDP25030
DVELDP250100DVELDP250300DVELDP32030
DVELDP320100DVELDP320300DVELDP40030
DVELDP400100DVELDP400300DVELDP63030
DVELDP630100DVELDP630300
DOUBLE POLE
FOUR POLE
DECOVOLT RCCB
14
AGAINST ELECTROCUTIONThe used of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock.
Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions.
• BREATHING• HEARTBEATA correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. However electro-cution should not be viewed in terms of “contact voltage”. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body.
AGAINST INDIRECT CURRENTOver current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50.
Example For and RCD with a rated tripping current of 30mA, the maximum permission earth fault loop impedance is calcu-lated as follows. Zs (max) = 50 /In = 50/0.03 = 1.666
DECOVOLT RCCB
PROTECTION
TECHNICAL INFORMATION
IEC 61008-125,32,40,63
30 - 100 - 300415660506
500A OR 10 Inwhichever is greater
-25 TO + 5540 MM FREE FALL
310000
DIN RAIL (35 X 7.5)MMIP 20
25
STANDARD CONFORMITYRATED CURRENT (In)SENSITIVITYRATED VOLTAGERATED INSULATION VOLTAGE(Ui)RATED FREQUENCY HzSHORT CIRCUIT WITHSTAND CAPACITY (kA)RESIDUAL MAKINGBREAKING CAPACITY AAMBIENT TEMPERATURESHOCK RESISTANCEVIBERATION RESISTANCE gELECTRICAL/MECHANICAL OPERATIONSMOUNTINGDEGREE OF PROTECTIONTERMINAL CAPACITY (MAX) sq.mm
IEC 61008-125,32,40,63
30 - 100 - 300240660506
500A OR 10 Inwhichever is greater
-25 TO + 5540 MM FREE FALL
310000
DIN RAIL (35 X 7.5)MMIP 20
25
IEC 60947-3:2001
5000166650166
Maximum permissible earth fault loop impedance in10mA30mA100mA300mA
Rated Tripping Current of the RCD
TWO POLE
15
Tripping Characteristics (IEC/EN 61008)Tripping characteristics, tripping time range an d selectivity of istantaneous, surge current-proof residual current circuit breaker.
Series connection of main RCCB and circuit RCCB's recommended by the installation rules set forth in ÖVE/ÖNORME 8001-1, is compulsory for agricultural installations according to §56 of ÖVE-EN1, Part 4.The device is ok if the result of measurement is within the time range specified by the manufacturer of the measuringinstrument.
Short description of the most important RCCB types:
Residual Current Circuit Breaker - General Data
Symbol Description
Standard. Suitable for outdoor installation (distribution boxes for outdoor installation andbuilding sites) up to -25ºC.
Conditionally surge-current proof (>250 A, 8/20 µs) for general application.
Press service key when putting the device into operation, and subsequently approximatelyonce per year. Pressing the key once per month is not required any more and can be omitted unless shorter testing intervals are required under any applicable regulations(e.g. on building sites).
Connection Diagrams
2-Pole 4-Pole
I n3 = 30 mA
I n2........I n1........ 2I n1........ 5I n1........
2I n2........ 5I n2........
conditionallysurge current-proof
Residual tripping current
Trip
ping
time
t
1000(ms)500
300
100
40
10
110 15 30
I n
10
40
10
40
10
150
300
10
50 100 150 200 500 1000 (mA) 500 A)
Tripping time range limit values
Tripping time range non-delayed
Area of unwanted tripping
DECOVOLT RCCB
16
Electrical energy has brought along with it a lot of conveniences, beyond imagination. It's consump-tion has increased manifold be it in domestic, commercial or industrial applications, there by creat-ing a need for scientific & effective method of distribution.
The purpose of electrical wiring is to systematically distribute current. In the process the system adopts methods to product hazards such as short circuit, over load and earth leakage
The electrical wiring is carried out to distribute current from a single source of supply to various circuits, such an arrangement is made inside an enclosure called Distribution board
The distribution board is not merely an enclosure but a comprehensive system in itself, comprising of copper busbars, brass neutral links, earth links to facilitate effective distribution of current, It incorpo-rates safety devices such as MCB's, ELCB's and Isolators, which serves to protect the installation.
A wide range of compact, elegant & economical DB's with unique features, designed & engineered to provide user safety, convenience and operational/ maintenance advantages are offered
Range
• Single Phase• Three Phase• Single Door• Double Door
• AESTHETICALLY SUPERIOR DB's TO SUIT THE STYLE OFF YOUR HOME DÉCOR
• CHOICE OF MULTIPLE INCOMER MCB, ISOLATOR, MCB+RCCB, CHANGEOVER + RCCB, ISOLATOR + RCCB +TPN RCBO
• READY TO USE DB'S THAT ARE SUPPLIED WITH NEUTRAL LINKS, EARTH LINKS, BUS BAR AND INTERNAL CONNECTING WIRES
• BUS BAR RATING - 100/200A
• COMPLETE RANGE OF DB'S WITH DETACHABLE GLAND PLATES AT THE TOP AND BOTTOM WITH KNOCKOUTS ON THE SIDES OF DB TO INCREASE THE FLEXIBILITY OF CABLES / CONDUIT ENTRY FROM ALL DIRECTIONS
DECOVOLT DISTRIBUTION BOARD
17
MCB DISTRIBUTION BOARDDecovolt distribution system in sheet steel enclosures is fabricated with utmost precision. Compact designs have been developed to ensure convenience and ease of installation and operation; they favorably match with the national and international technology.
CONSTRUCTIONThe enclosures are fabricated out of best quality CRCA steel sheet for better strength and finish. The distribution systems are supplied duly fitted with Din channel, neutral link earth bar and bus bar, so that the MCB’s of desired number of ratings can be fitted conveniently at site, except for one to four pole enclosures, which are only fitted with Din channel.
POWDER PAINTHigh quality powder paint coated and baked at high temperature, before powder coating the housing go through anti-rust conditioning in seven tank processes to ensure smooth and lasting finish and protection against corrosive atmosphere. All type of DB’s are available in single and two tone colour.
Decovolt elegant distribution systems are designed with the best combination of engineering technology and aesthetic to suit various applications.
All DB’s available with and without MCB’s
Single Phase and neutral sheet steel powder coated double door distribution system fitted with two cover one screwed cover for incoming and outgoing for MCB and second for protection of MCB’s, fitted with bus bar, neutral link , earth bar, and din rail, Suitable for use on 240/415Vv, 50 Hz supply.
WAYS4681216
CAT NODVDD04DVDD06DVDD08DVDD012DVDD016
TO ACCOMMODATE4 Nos. SP MCB6 Nos. SP MCB8 Nos. SP MCB12 Nos. SP MCB16 Nos. SP MCB
DOUBLE DOOR SP & N DISTRIBUTION
NO OF WAYS AND DIMENSION DETAILS
WAYS4681216
A170205240310380
B240240240240240
C8686868686
D140175210280350
E210210210210210
F90125160230300
G160160160160160A
B EG
C
DF
DECOVOLT DISTRIBUTION BOARD
18
CONSUMER UNIT WITH POLYCARBONATE COVER
Single phase and neutral sheet steel powder coated distribution system with poly carbonate transparent cover for protection of MCB’s fitted with 40/63A DP Isolator or ELCB as incomer and fitted with bus bar, neutral link, earth bar and din rail. Suitable for use on 240/415V, 50 Hz.
WAYS4681216
CAT NODVCUDD04DVCUDD06DVCUDD08DVCUDD012DVCUDD016
TO ACCOMMODATE4 Nos. SP MCB6 Nos. SP MCB8 Nos. SP MCB12 Nos. SP MCB16 Nos. SP MCB
NO OF WAYS AND DIMENSION DETAILS
WAYS4681216
A224259294329364
B224224224224224
C6363636363
D210245280315350
E210210210210210
F160195230265300
G160160160160160
VERTICAL DOUBLE DOOR TP & N DISTRIBUTION SYSTEM FITTED WITH FP ISOLATOR
Three phase and neutral sheet steel powder coated distribution system for single/multi phase out going fitted with colour coated bus bar , neutral link, Earth bar, and din rail. Suitable for use on 240/415v, 50 Hz supply. DB is provided with detachable gland plates
WAYS6812
CAT NODVCUDD06DVCUDD08DVCUDD012
TO ACCOMMODATE6 Nos. SP MCB8 Nos. SP MCB12 Nos. SP MCB
NO OF WAYS AND DIMENSION DETAILS
WAYS6812
A170205240
B240240240
C868686
D140175210
E210210210
F90125160
G160160160
Three phase and neutral sheet steel powder coated distribution system for single/multi phase out going fitted with colour coated bus bar , neutral link, Earth bar, and din rail. Suitable for use on 240/415v, 50 Hz supply. DB is provided with detachable gland plates
NO OF WAYS AND DIMENSION DETAILS
A
B EG
C
DF
A
B EG
C
DF
DECOVOLT DISTRIBUTION BOARD
19
DECOVOLT RECESSED AND SURFACE MOUNTED LUMINARIES ARE SUITABLE FOR GENERAL LIGHT-ING, APPLICATIONS IN INDOOR AREAS SUCH AS OFFICES, COMPUTER ROOMS, SCHOOLS, HOSPI-TALS AND COMMERCIAL AREAS SUCH AS SHOPS DECOVOLT WEATHER PROOF LUMINARIES ARE SUITABLE FOR DAMP/DUSTY ENVIRONMENTS SUCH AS INDUSTRIAL PREMISES, FACTORIES, POWER PLANTS, POWER DISTRIBUTION STATIONS, WAREHOUSES CAR PARKS. MATERIAL FINISH CHASSIS OF RECESSED AND SURFACE MOUNTED FIXTURES ARE MADE OF CRCA SHEET STEEL, CHEMICALLY CLEANED, TREATED PHOSPHATED & POWDER COATED WITH RAL 9010 ON BOTH SIDES, TO GIVE HIGH REFLEC-TIVE SURFACE FINISH DECOVOLT WETHER PROOF HOUSING MADE OF COMPRESSION MOULDING GLASS REINFORCED POLYESTER (GRP), DIFFUSER UV STABILIZED PMMA / POLYCARBONATE, TRAY PRETREATED WHITE POWDER COATED CRCA SHEET STEEL END CAPS ARE MOULDED POLYAMIDE 66, IT ALLOWS EASY ASSEMBLY OF LAMP HOLDERS GASKETS ARE MOULEDE POLYURETHANE RUBBER WHICH PROVIDES FOR IP-65 BALLASTS ARE ENERGY EFFICIENT WITH LOW ENERGY LOSS, NOISELESS OPERATIONS, LOW OPERATING TEMPERATURE, AND MINIMUM TEMPERATURE RISE, ELECTRONIC BALLAST OPTIONAL LAMP HOLDERS ARE WITH G5 AND G13 BASE AND BODY, MADE OF FLAME RETARDANT POLY CARBONATE PLASTIC AND PHOSPHER BRONZE CONTACT STARTER HOLDER ARE MADE OFF LAME RETAR-DANT POLYCARBONATE PLASTIC WITH PHOS-PHER BRONZE CONTACT
LOCKING CLIPS ARE MADE OF POLYCARBONATE / STAINLESS STEEL
INTERNAL WIRING WITH PVC INSULATED HEAT RESISTANT SINGLE STRAND COPPER WIRE.
• DECOVOLT FLUORESCENT BATTENS ARE SUITABLE FOR T8 AND T5 FLUORESCENT LAMPS, AVAILABLE IN SINGLE, DOUBLE AND TRIPLE TUBE VERSIONS
• DECOVOLT MODULAR RECESSED AND SURFACE FLUORESCENT LUMINARIES ARE SUITABLE FOR T5 AND T8 FLUORESCENT LAMPS AVAILABLE IN IP-20 AND IP -40 RATINGS
• DECOVOLT WEATHER PROOF LUMINARIE SUITABLE FOR SINGLE OR TWIN T5 OR T8 LAMPS OPERATED BY HF OR ELECTROMAGNETIC BALLAST, AVAILABLE IN IP-65 PROTECTION
DECOVOLT FLUORESCENT LUMINARIES
20
TECHNICAL DATA MATERIAL & FINISH
Type Lamp Rating Dimensions mmCode L W H
DV 120 1 x 18 W 618 52 72DV 220 2 x 18 W 618 100 79DV 140 1 x 36 W 1228 52 72DV 240 2 x 36 W 1228 100 79
DV T8 SeriesSURFACE MOUNTEDBATTEN LUMINAIRE
Description:
Decovolt fluorescent Batten luminarie suitable for single fluorescent T8 lamp from 18W to 36 W. The luminarie is suitable for suspended or surface mounted application.
Application:Suitable for general lighting applications in indoor areas like offices, schools, hospitals and commer-cial areas like shops etc.
Features: • Sturdy construction.• Switch start circuit.• Easy to install & maintain• Low Energy loss ballast & High ballast factor for maximum light output.• Internal wiring with heat Resistant (105°C) single strand copper wire.
Options:
• HPF capacitors• Electronic starters• High freq. Electronic ballasts• HF circuits, RFI capacitors• Other voltage and frequency.
Batten Frame: 0.4 mm thick pre-treated and Powder coated cold rolled steel sheet with 25 microns paint thickness of color RAL 9016.
Ballast: Decovolt Low energy loss, noiseless, operation, low operating temperature, minimum temperature rise. The ballast fixed with screws, nuts & serrated washer ensures positive locking and proper earthing. End Caps: Separate 2 nos. of Polycarbonate end caps are provided, which are flame retardant and self -extinguishing type. Plastic end caps improve the aesthetics of the fixtures. The fixing of lamp holders is simple - slide fit.
Lamp & Starter holders: Flame -retardant polycarbonate with phosphor bronze contacts.
Wiring: PVC insulated single strand heat resistant wire
Dimensional details:
DECOVOLT FLUORESCENT BATTEN
21
DECOVOLT FLUORESCENT LUMINAIRES
MODULAR RECESSEDDV- STD SERIES
The Louvre is made of high
purity aluminum sheets with
single parabolic shape and with
ribbed cross blades. The louver
assembly is suspended in the
chassis by anticorrosive
one springs. The luminaire
is also available with back
reflectors on request.
220V110V 230V 240V
IP20
60Hz50Hz
DEOStarter
HPFCapacitor
RFCapacitor
HFBallast
EmergencyBatteryPack
FI
OPTIONS
Modular Recessed fluorescent luminaires are suitable for T5 & T8 / T12 Fluorescent lamps. This can be operated by Electromagnetic or Electronic Ballast & can be installed in exposed /concealed T-grid applications.Application:Chassis: Made of CRCA sheet steel, chemically cleaned, treated, phosphated & powder coated with RAL 9010 on both inside & outside to give high reflective surface finish.
Ballast: Energy efficient electromagnetic ballast, with Low energy loss, noiseless operation, low operating tempera-tures & minimum temperature rise. Electronic Ballast Optional.
Lamp holders: With G5/G13 base & body made of Flame-retardant polycarbonate plastic with phosphor bronze contact.
Starter holders: Made of Flame-Retardant poly carbonate plastic with phosphor bronze contact.
Internal Wiring: With PVC insulated, heat resistant (105°C) single strand Copper wire.
22
FLUORESCENT LUMINARIESWEATHER PROOF - DV T8 SERIES 220V110V 230V 240V
IP65
60Hz50Hz
DEOStarter
HPFCapacitor
RFCapacitor
HFBallast
EmergencyBatteryPack
FI
OPTIONS
L2L1
100 168
108
DVP 118 1X18 W 665 230
DVP 136 1X36 W 1275 836
DVP 158 1X58 W 1575 1136
DVP 218 2X18 W 665 230
DVP 236 2X36 W 1275 836
DVP 258 2X58 W 1575 1136
Length in mmModel Lamps
L1 L2
Integrated Emergency Battery Packis not available in 18W version.
DECOVOLT FLUORESCENT LUMINAIRES
Weatherproof Luminaire suitable for single or twin, T5 or T8/T12 fluorescent lamps operated by HF or Electromag-netic Ballast. Application: Suitable for damp/dusty environments such as Industrial premises, factories, power plants, power distribution stations, warehouses, car parks.
Material & Finish:Housing: Compression moulded glass reinforced polyester (GRP)Diffuser: UV stabilized PMMA / Polycarbonate.Tray: Pre-treated, White powder coated CRCA Sheet steelGaskets: Moulded Polyurethane rubber which provides for IP65Locking Clips: Polycarbonate / stainless steel (Optional)Lamp & starter holders: Made of flame retardant Polycarbonate with phosphor bronze contacts.
Wiring: PVC insulated single strand copper wire that can withstand a temperature of 105˚CBallast: Low energy loss, noiseless operation, low operating temperatures, minimum temperature rise.
23
NOTES
24
NOTES
25
HEADQUARTERS
INTERPLAST CO. LTDP.O.Box: 4679, Sharjah, UAE
Tel: +971 6 5335577, +971 6 5339090Fax: +971 6 5395775, +971 6 5336905
E-mail: intrplst@emirates.net.ae
INTERPLAST CO. LTD. (Saudi Arabia)P.O. Box 270982 Riyadh 11352
Kingdom Of Saudi Arabia, Tel: +966 14714667+966 14716773 Fax: +966 14714669
E-mail:ipc@atheer.net.sa
INTERPLAST UK.LTD.15 High Street, Inverurie, Aberdeenshire AB51 3QA
Tel: (+44) 01467 629555Fax: (+44) 01467 672191
E-mail: sales@interplast.co.ukwww.interplast.co.uk
Web site: www.interplast.aewww.edisonelectricalproducts.com
INTERPLAST COMPANY LIMITEDMember of Group Harwal
LOW VOLTAGE ELECTRICAL COMPONENTS
top related