k2 energy executing engineering excellence - li-ion bms · executing engineering excellence high...
Post on 03-Dec-2018
216 Views
Preview:
TRANSCRIPT
Executing Engineering Excellence
HIGH CAPACITY K2B3V41P POWER MODULE DATA
DIMENSIONS:
SPECIFICATIONS:Nominal Capacity @ C/5 (Ahr) ........................... 41.6Average Operating Voltage @ C/5 ....................... 3.2Weight (kg) ........................................................... 1.8Height (mm) .........................................................133Width (mm) ........................................................... 81Length (mm) ........................................................123
RECOMMENDED OPERATING CONDITIONS:Continuous Discharge (A) .............................. ≤160Pulse Discharge (A) 30 seconds .......................... 400Charge Current (A) .............................................. ≤10Charge Voltage Cutoff (V) ................................... 3.65Discharge Voltage Cutoff (V) ............................... 2.5High Temp Operating Temp (°C) ............................ 60Low Temp Operating Temp (°C) ........................... -20
MAXIMUM OPERATING CONDITIONS:Continuous Discharge (A) ................................. ≤675Pulse Discharge (A) ≤2 seconds ....................... 2400Charge Voltage Cutoff (V) .................................... 4.1Discharge Voltage Cutoff (V) ............................... 2.0
Performance may vary depending on application. All specifications and operation conditions are subject to change without notice. This data is for evaluation purposes only. No guarantee is intended or implied by this data.
1125 American Pacific Drive, Suite C • Henderson, NV 89074 • 702.478.3590 • www.K2battery.com
K2 Energy®
K2B3V41P Constant Current Time Profile @ 25°CC/20
(2.08 A)C/2
(20.8 A)1C
(41.6 A)2C
(83.2 A)3.3C
(137 A) 20 hrs 2 hrs 60 min 29 min 16 min
Volts
(V)
Capacity (Ah)
K2B3V41P Discharge Curves at Different Rates
2.2
2.4
2.6
2.8
3.0
3.2
3.4
2.00 10 20 30 40 50
80A 320A 640A
MDS P0001/A