key applications in project business · 13 rebar applications canopy subframe high-tension loads at...

Post on 23-Jul-2020

4 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Key applications in project business

3

3 Content 22 Facade applications 39 Special applications in tunnels

4 Strengths of fischer 23 Facade applications 40 Cameras, emergency phones

5 Temporary works/ site installation 24 Windows 41 Sign posts and traffic lights

6 Formwork 25 Interior works 42 Fan systems

7 Temporary fixings 26 Partition walls 43 Smoke extraction plenums

8 Temporary fixings 27 Wall and ceiling 44 Electric installation, pipe racks

9 Temporary fixings 28 Sanitary ware 45 Further tunnel applications

11 Structural works 29 Sanitary ware 47 Special applications on bridges

12 Rebar applications 30 Installations 48 Noise barriers

13 Rebar applications 31 Installations 49 Crash barriers

14 Steel structure 32 Air conditioning and ventilation 50 Railings

15 Railing 33 Air conditioning and ventilation 51 Wastewater disposal pipes

17 Building envelope 34 Water treatment equipment 52 Further bridge applications

18 Brickwall 35 Cooling / chilled water systems 53 About...

19 Facade applications 36 Safety 56 Contact

20 Facade applications 37 Safety

Content

4

Innovations

Safety

Strengths of fischer

Project ServicesIn Germany, an average of appr. 9.28 patent applications for every 1,000 employees each year (industry average: appr. 0.75) 35 % implementation of patents in products, procedures, and applications (industry average: 10 %)Tailor-made customer solutions fischer Process System: adjusting processes specifically to meet the customer’s needs

Project-related special developments

Consulting in application engineering

High-tech product solutions

User-friendly calculation software

Global presence in over 100 countries

Highest quality standards

Special solutions for the most complex applicationsLeading the way in approvalsfischer nylon quality guaranteeMaximum load dataOwn development and production of nylon, steel and chemical fixingsISO 9001 Certification

Temporary works/site installation

6

Formwork

Tilt-up applications

EA

FMB 

An easy and economical solution for temporary applications like fixing of formwork is the FMB Multi Bolt

R M + RG M

FBN II

FIS V/VS/VT/VW

Our Specialists

7

Temporary fixings

Temporary equipment fixing

FDBB EA II M 12 D

The fixing set for diamond drilling machines

A robust unit specially for the rough on-site conditions, protected internal thread and high quality steel

Active controlled expansion behaviour guarantees high security in use

Unit also tolerates skew bolt positions and jerky tilting of the drill bit

Large steel cross-section at the concrete surface provides high steel load-bearing capability

Protected internal thread and high-quality steel increase the long life of the spindle bolt and improve cost efficiency

Reusable spindle, washer and nut save costs

Our Specialists

8

Temporary fixings

Tracks and steel structures

FAZ II

FBN II

Temporary fixings have to be cost-efficient and depending on the duration and the surrounding conditions

Heavy duty anchors with long threads are suitable for adjusting stand-off fixing on bumpy concrete slabs like fischer FAZ II or FBN II

FIS V/ VS/ VT/ VW

FBS (in UK) 

Our Specialists

FAZ II

9

Temporary fixings

Temporarily used cables and pipings

FAZ II 

FBN II

Temporary fixings have to be cost-efficient, you have to take in account the duration of the fixation and the conditions

For these fixings zinc-plated steel can be used

Bolt anchors like FBN II or FAZ II are a good choice for this application

FIS V/ VS/ VT/ VW

FBS (in UK) 

Our Specialists

Structural works

12

Rebar applications

Starter bars

Strengthening

FIS EM

FIS EM

FRA

FIS V/ VS/ VT/ VW

FIS V/ VS/ VT/ VW

Our Specialists

Our Specialists

13

Rebar applications

Canopy subframe High-tension loads at low edge distances and spacings

Transfer of loads to the available reinforcement in the component by way of overlapping splices for maximum load utilisation

FRA: Metric thread in stainless steel A4 or 1.4529 for reliable use inside and outside

FRA also for fixing of steel constructions, railings, consoles, machines and staircases

FRA

FIS V/ VS/ VT/ VW

Our Specialists

14

Steel structure

Fix steel part to concrete structure Permanent construction equipment has to be fixed for reliable function

Heavy duty anchors with long threads are suitable for adjusting stand-off fixing on bumpy concrete slabs

FH II

FZA

FAZ II  FHB II

R M + RG M

FBN II

FIS V/ VS/ VT/ VW

Our Specialists

15

Railing

Fixing of balustrades Small edge distances are an important factor for this application

FH II‐SK

FH II‐H 

FAZ II 

EXA

FBN II

FIS V/ VS/ VT/ VW

Our Specialists

R M + RG M

Building envelope

Brickwall

Refurbishment

18

Our Specialists

Brickwall

EA‐N

FSL 

Cladding tie VB

brickwall:

and SXR, SXS, FUR, GB

R M + RG M

refurbishment:

VBS

FIS V/ VS/ VT/ VW

Our Specialists

19

Facade applications

Applied Masonry Façades

FAZ II

Masonry façades are assembled with several products

They do not hang onto the structure as a single, framed system

Is constructed of individual bricks, blocks, tiles or pieces of stone

R M + RG M

FBN II

FIS V/ VS/ VT/ VW

Our Specialists

20

Facade applications

External wall insulation

Thermofix CF 8

Thermoz 8 NZ

Thermoz 8 UZ

The systems comprise prefabricated insulation product bonded onto the wall, or mechanically fixed using anchors, profiles, special pieces, etc...

Also a combination of adhesive and mechanical fixings is possible

The insulation product is faced with a rendering consisting of one or more layers (site applied)

Our Specialists

Exposed Structure Facades

21

Our Specialists

Facade applications

The Specialists:

The building's structural framework is not covered

It may either be exposed directly to the outdoors or painted; the rest of the enclosure is formed by filling the openings in the framework with windows and/or panels of any suitable material

Common with concrete structures but not with metal-framed buildings, because structural metal cannot usually be exposed to the air

FAZ II

FHB II

FBN II

SXS

SXR

22

Facade applications

Curtain Wall Facades

SXS FAZ II

Continuous sheet of panels hung onto the side of a building over the framework

Sheets may be prefabricated panels or assembled at the construction site

Any façade material can be used in a curtain wall (including prefabricated concrete, metal, glass, industrial panels, and stone or masonry sheets)

FHB II

RM 

RGM

FIS V/ VS/ VT/ VW

Our Specialists

23

Substructure

The key to new façade aesthetic, allows architects and planners to design facades without visible fixing elements

Flexibility to use glass and stone materials

Andvantages of the FZP-system:

invisible high maximum load

no transfixion low panel thickness

FZP

Facade applications

A | C | T

Our Specialists

24

Windows

Window frames and sealing Rapid hardening foam reduces processing time

Noise-reducing properties

Highest foam yield

Wide range of products for different applications

Nylon anchors with premium performance for highest loads

F‐S

F‐M

SXS

FFSfoam range

SXR

FUR

Our Specialists

Interior works

26

Partition walls

Dry-walls

SX

UX

HM

The Specialists:

Fast and easy installation of railing systems for dry-walls

Fixings for every kind of building material

GK

FNA II

FNH

UN

Our Specialists

27

Our Specialists

Wall and ceiling

Suspended ceilings and panels Fast and easy carrying out of serial installations

Safe solutions also proofed in cracked concrete

FNA II

EA II

FBS 

FDN

FZEA II

FBN II

FIS V/ VS/ VT/ VW

28

Our Specialists

Sanitary ware

Wash basin and urinal fixings WD, WST, UST are fixing sets consisting of UX-Plugs, stud screws, nylon

nuts or flanged bushes with hexagon nut

KM and WDP are specially designed for fixing washstands and urinals to plumbing units and cavity walls

Pre-positioned or stud-bolt installation

WD

WST

UST

KM

WDP

29

Our Specialists

Sanitary ware

WC and sanitary fixings WCN is the standard WC fixing with chrome or white coloured cap

The toilet fixing WB 5 N is an invisible fixing for standing WC’s and bidets

WCN

WL

WB 5N

30

Installations

Electrical cables Easy and fast installation of all kind of cable fixings

One piece fixing – saves plug, clamp and screw (LS)

SD

RC

LS

ZS

KB

NS

BSM

SHA

MS

Our Specialists

31

Installations

Cable trays and piping

FNA II

SaMontec 

Channels

Accessories

High flexibility due to compatible system components

Economic installation due to time-saving, user-friendly products

Safe installation due to high-quality system components and optimum fixings for all building materials

FBN II

EA II

System

FAZ II

TA M

FHY

FZEA II

Our Specialists

32

Air conditioning and ventilation

Aircon ducts Fixing of spiral and rectangular ducts in concrete and steel beams

FAZ II

TKL

EA II

FBN II

LGS

FZEA II

FNA II

TA M

FHY

Our Specialists

Notice also the SaMontec range

33

Our Specialists

Air conditioning and ventilation

Aircon sytems

(for the outdoor units):

MCE

Product of fiit

SX 12 BM 

(for the indoor units):

EA II

FZA

TA M

SL M

Notice also the SaMontec range

Fixing of aircon systems with special frames and heavy duty anchors (outdoor and indoor units)

34

Our Specialists

Water treatment equipment

Water pipes Fixing of water pipes to floor, wall and ceiling

EXA 

FBN II FAZ II 

FZA 

Notice also the SaMontec range

35

Cooling / chilled water systems

Pipe clamps Special insulated clamps

For fastening pipes in refrigeration and air conditioning technology

KFT

FRS F

FRS K

FRS Plus

FGRS Plus

Our Specialists

Notice also the SaMontec range

36

Safety

Sprinkler systems Again function conservation is required mostly

Fire test reports and approvals certify the suitability of the fischer heavy duty anchors

FRSP

FAZ II

FZEA II

EA II

FBN II

FNA II

TKL

FGRS PlusFRS Plus

Our Specialists

Notice also the SaMontec range

37

Fire barrier systems are measures for preventative, structural fire protection. They serve to minimize or contain dangers posed by fire and smoke

Structural fire protection in a building is always “preventative fire protection”

Preventative fire protection measures serve to prevent fire from breaking out and/or spreading, and to secure escape routes and emergency exits in buildings

This group of protective measures also includes passively operating structural measures such as bulkheads

FM

FBP FAB, FAS

FBB

FBK

FBM

SafetyFire protection

Our Specialists

Special applications in tunnels

40

Our Specialists

Infrastructure

Cameras, emergency phones

FZEA II

FNA II

FAZ II

FZA 

FH II

For safety arrangements fast and safe installation is necessary

fischer steel anchors fit to these requirements

41

Our Specialists

Infrastructure

Sign posts and traffic lights

FHB II

FHB dyn

FZA 

FZEA II

FNA II

With this kind of fixings often small spacings and/ or edge distances in combination with high wind loads exist

Therefore anchors with small permissible spacings and edge distances like FAZ meet the demands perfectly

R

FAZ II

FBN II

FH II

FIS V/ VS/ VT/ VW

42

Our Specialists

Infrastructure

Fan systems

FHB dyn

Variable effective lengths depending on anchor stud for more flexibility

More economical standard production installation reduces installation time

Only one work step and cost savings: FIS HB sealing resin simultaneously fills the ring slot during setting procedure

43

Our Specialists

Infrastructure

Smoke extraction plenums

FZA 

FHB II

44

Infrastructure

Electric installation, pipe racks, supply units

FBN II

FAZ II

FZA 

FNA II

SaMontec pipe clamps and channels

The channel anchor FNA 6x40 S was especially developed for fixing of lightweight channels

Our Specialists

Notice also the SaMontec range

45

Infrastructure

Further applications This chapter only contains special tunnel applications. Further

applications can be found in other parts of this document

Fixing of formwork: Page 6

Fixing of steel structure e.g. concrete mixing units: Page 9

Temporary fixings: Pages 11, 12, 13

Special applications on bridges

48

Our Specialists

Infrastructure

Noise barriers Noise barriers are exposed to high wind pressure forces due to

crosswinds and additional negative pressure due to the impact pressure of the train

FAZ II

FHB II

FRA

R M + RG M

FIS V/ VS/ VT/ VW

49

Our Specialists

Infrastructure

Crash barriers/ guard rails

FAZ II

Guard rails on bridges are necessary to prevent vehicles which have difficulties from falling off the bridge

This is done by absorbing the kinetic energy by deformation of the steel profiles

The anchor plate and the anchors have to reliably resist these forces

FBN II

FHB II

FIS V/ VS/ VT/ VW

50

Our Specialists

Infrastructure

Railings Railings on bridges are often fixed to thin building substrates like rim

beams with small axial spacings and edge distances

Therefore expansion-free systems are required

Additionally the anchors are exposed to high concentrations of de-icing salt

FAZ II

FHB II

FRA

R M + RG M

FIS V/ VS/ VT/ VW

51

Our Specialists

Infrastructure

Wastewater disposal pipes Service pipes are often heavy weighted and cause temperature strains

Again function conservation is mainly required

These demands have also to be covered by the fixing

R M + RG M

FAZ II

FBN II

FHB II

FZEA II

FIS V/ VS/ VT/ VW Notice also the SaMontec range

52

Infrastructure

Further applications This chapter only contains special bridge applications.

Further applications can be found in other parts of this document

fixing of formwork: Page 6

fixing of steel structure e.g. concrete mixing units: Page 9

temporary fixings: Pages 11, 12, 13

53

Thank you!

Various employees and departments of the fischer Group of Companies worked on the creation of this document.Special thanks belongs to the technical sales support, international marketing dept. and our colleagues from all over the world.Many of the used pictures and much of the used information originates from the sales presentations -thanks to the editors of those presentations for the great work.

About…

This collection of applications is only possible with input of fischer employees from all over the world. In different countries, problems are fixed with a different solution.We are interested to sum up all those solutions in this document.If you miss an application in the document or if you have an interesting solution to share, please do not hesitate to contact us and send the information to:

- Harry.Blaskowitz@fischer.de or

Please help us!

56

fischerwerke GmbH & Co. KG

Weinhalde 14-18

72178 Waldachtal

Germany

Phone +49 7443 12-0

Fax +49 7443 12-4222

www.fischer.de

Contact

top related