lab number 1 lab results ratings average popstddev z score...2020 fine aggregate round robin report...

Post on 30-Sep-2020

2 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

2020 Fine Aggregate Round Robin Report

Lab Number 1

99.9

78.9

Total Percent Passing the #4 Sieve

38.8

19.8

9.6Total Percent Passing the #50 Sieve

3.4

1.30

5

3

4

4

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.21

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.06

0.13

-1.72

-1.31

-1.13

-0.84

-0.76

-0.06

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 2

99.9

85.5

Total Percent Passing the #4 Sieve

48.7

26.8

12.8Total Percent Passing the #50 Sieve

4.6

1.34

5

4

4

4

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.83

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.12

0.13

1.07

1.06

1.01

0.80

0.49

0.00

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 3

100.0

80.0

Total Percent Passing the #4 Sieve

41.0

23.0

11.0Total Percent Passing the #50 Sieve

4.0

1.42

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.06

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.41

0.47

-1.25

-0.78

-0.16

-0.12

-0.14

0.13

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 4

100.0

84.0

Total Percent Passing the #4 Sieve

48.7

25.8

13.0Total Percent Passing the #50 Sieve

4.8

1.60

5

5

4

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.94

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.78

0.47

0.43

1.06

0.70

0.91

0.70

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 5

98.5

78.9

Total Percent Passing the #4 Sieve

39.3

20.6

9.2Total Percent Passing the #50 Sieve

2.4

0.20

0

3

4

5

4

3

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.94

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.78

-4.65

-1.72

-1.19

-0.89

-1.05

-1.81

-1.84

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 6

98.8

81.7

Total Percent Passing the #4 Sieve

42.8

22.8

10.8Total Percent Passing the #50 Sieve

3.5

0.70

0

5

5

5

5

5

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.80

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.21

-3.62

-0.54

-0.35

-0.22

-0.22

-0.66

-1.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 8

100.0

80.5

Total Percent Passing the #4 Sieve

42.1

22.3

10.7Total Percent Passing the #50 Sieve

4.0

1.39

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.99

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.62

0.47

-1.04

-0.52

-0.37

-0.28

-0.14

0.08

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 9

99.9

82.0

Total Percent Passing the #4 Sieve

42.2

22.2

10.4Total Percent Passing the #50 Sieve

3.8

1.21

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.00

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.59

0.13

-0.41

-0.50

-0.40

-0.43

-0.35

-0.21

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 10

100.0

83.5

Total Percent Passing the #4 Sieve

44.0

23.5

11.4Total Percent Passing the #50 Sieve

4.8

4.50

5

5

5

5

5

5

0

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.27

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.25

0.47

0.22

-0.07

0.00

0.08

0.70

5.11

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 12

99.8

84.9

Total Percent Passing the #4 Sieve

43.6

24.9

12.1Total Percent Passing the #50 Sieve

4.9

1.61

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.90

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.90

-0.21

0.81

-0.16

0.43

0.44

0.80

0.44

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 14

99.8

81.6

Total Percent Passing the #4 Sieve

43.1

23.1

11.8Total Percent Passing the #50 Sieve

4.6

1.66

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.30

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.34

-0.21

-0.58

-0.28

-0.13

0.29

0.49

0.52

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 16

99.9

83.9

Total Percent Passing the #4 Sieve

47.0

25.0

13.1Total Percent Passing the #50 Sieve

4.9

1.55

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.15

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.13

0.13

0.39

0.65

0.46

0.96

0.80

0.34

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 18

100.0

87.6

Total Percent Passing the #4 Sieve

54.4

31.9

16.4Total Percent Passing the #50 Sieve

6.4

1.99

5

3

2

1

1

2

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 0.59

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.86

0.47

1.95

2.42

2.57

2.65

2.37

1.05

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 19

99.9

83.6

Total Percent Passing the #4 Sieve

46.4

25.2

12.4Total Percent Passing the #50 Sieve

4.9

1.67

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.51

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.99

0.13

0.27

0.51

0.52

0.60

0.80

0.53

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 20

100.0

83.7

Total Percent Passing the #4 Sieve

46.5

26.0

12.4Total Percent Passing the #50 Sieve

4.8

1.77

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.63

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.36

0.47

0.31

0.53

0.76

0.60

0.70

0.70

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 22

99.9

84.3

Total Percent Passing the #4 Sieve

47.1

26.3

13.4Total Percent Passing the #50 Sieve

5.6

2.09

5

5

5

5

4

3

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

1Percent Loss by T11 (P200 Wash) 2.09

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

2.79

0.13

0.56

0.68

0.85

1.11

1.53

1.21

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 24

100.0

85.8

Total Percent Passing the #4 Sieve

47.9

26.4

12.7Total Percent Passing the #50 Sieve

5.0

1.90

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

2Percent Loss by T11 (P200 Wash) 1.86

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

2.08

0.47

1.19

0.87

0.88

0.75

0.91

0.91

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 28

100.0

84.7

Total Percent Passing the #4 Sieve

46.0

24.4

11.4Total Percent Passing the #50 Sieve

4.5

1.50

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.24

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.15

0.47

0.73

0.41

0.27

0.08

0.39

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 29

100.0

84.0

Total Percent Passing the #4 Sieve

46.7

26.3

12.7Total Percent Passing the #50 Sieve

4.9

1.70

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.39

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.62

0.47

0.43

0.58

0.85

0.75

0.80

0.58

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 32

100.0

82.1

Total Percent Passing the #4 Sieve

41.7

21.2

9.8Total Percent Passing the #50 Sieve

3.6

1.20

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.04

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.47

0.47

-0.37

-0.61

-0.71

-0.74

-0.55

-0.23

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 33

99.6

86.0

Total Percent Passing the #4 Sieve

48.2

26.2

12.7Total Percent Passing the #50 Sieve

4.8

1.56

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.35

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.49

-0.89

1.28

0.94

0.82

0.75

0.70

0.36

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 34

100.0

84.1

Total Percent Passing the #4 Sieve

42.4

21.2

10.1Total Percent Passing the #50 Sieve

3.4

1.14

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.91

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.87

0.47

0.48

-0.45

-0.71

-0.58

-0.76

-0.32

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 35

100.0

82.8

Total Percent Passing the #4 Sieve

44.5

24.3

12.3Total Percent Passing the #50 Sieve

4.9

1.70

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.20

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.03

0.47

-0.07

0.05

0.24

0.55

0.80

0.58

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 37

100.0

82.5

Total Percent Passing the #4 Sieve

41.1

21.1

9.9Total Percent Passing the #50 Sieve

3.8

1.36

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.08

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.34

0.47

-0.20

-0.76

-0.74

-0.69

-0.35

0.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 39

99.8

77.1

Total Percent Passing the #4 Sieve

35.6

17.3

8.1Total Percent Passing the #50 Sieve

3.4

1.40

5

2

2

3

3

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.26

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.22

-0.21

-2.48

-2.07

-1.90

-1.61

-0.76

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 40

99.9

83.4

Total Percent Passing the #4 Sieve

47.9

25.5

11.9Total Percent Passing the #50 Sieve

4.5

1.44

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.26

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.22

0.13

0.18

0.87

0.61

0.34

0.39

0.16

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 41

100.0

80.5

Total Percent Passing the #4 Sieve

36.5

17.4

7.7Total Percent Passing the #50 Sieve

2.7

1.02

5

4

3

3

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.90

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.90

0.47

-1.04

-1.86

-1.87

-1.82

-1.49

-0.52

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 42

99.9

89.3

Total Percent Passing the #4 Sieve

55.3

31.0

15.3Total Percent Passing the #50 Sieve

5.0

1.60

5

1

1

2

2

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.29

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.31

0.13

2.67

2.63

2.29

2.09

0.91

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 43

98.6

81.4

Total Percent Passing the #4 Sieve

42.6

21.8

9.8Total Percent Passing the #50 Sieve

3.0

0.30

0

5

5

5

5

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.31

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.37

-4.31

-0.66

-0.40

-0.52

-0.74

-1.18

-1.68

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 45

100.0

80.6

Total Percent Passing the #4 Sieve

40.6

20.7

9.7Total Percent Passing the #50 Sieve

3.6

1.21

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.80

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.21

0.47

-1.00

-0.88

-0.86

-0.79

-0.55

-0.21

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 47

100.0

84.4

Total Percent Passing the #4 Sieve

47.5

26.9

13.4Total Percent Passing the #50 Sieve

5.1

1.68

5

5

5

4

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.48

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.90

0.47

0.60

0.77

1.04

1.11

1.01

0.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 48

99.8

85.4

Total Percent Passing the #4 Sieve

45.0

23.9

11.4Total Percent Passing the #50 Sieve

4.2

1.46

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 0.63

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.74

-0.21

1.03

0.17

0.12

0.08

0.07

0.20

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 50

99.6

81.2

Total Percent Passing the #4 Sieve

39.5

19.0

8.1Total Percent Passing the #50 Sieve

2.9

1.20

5

5

4

4

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.20

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.03

-0.89

-0.75

-1.14

-1.38

-1.61

-1.28

-0.23

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 51

99.8

80.2

Total Percent Passing the #4 Sieve

38.6

18.4

8.0Total Percent Passing the #50 Sieve

2.7

0.80

5

4

4

3

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.83

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.12

-0.21

-1.17

-1.35

-1.56

-1.66

-1.49

-0.87

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 52

99.9

79.8

Total Percent Passing the #4 Sieve

38.2

18.8

9.0Total Percent Passing the #50 Sieve

3.7

1.45

5

4

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.24

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.15

0.13

-1.34

-1.45

-1.44

-1.15

-0.45

0.18

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 53

99.9

80.1

Total Percent Passing the #4 Sieve

39.7

19.8

9.3Total Percent Passing the #50 Sieve

3.5

1.40

5

4

4

4

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.27

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.25

0.13

-1.21

-1.09

-1.13

-1.00

-0.66

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 54

99.8

84.5

Total Percent Passing the #4 Sieve

44.1

22.7

10.5Total Percent Passing the #50 Sieve

3.9

1.30

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.85

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.06

-0.21

0.65

-0.04

-0.25

-0.38

-0.24

-0.06

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 55

100.0

86.0

Total Percent Passing the #4 Sieve

49.2

27.7

13.3Total Percent Passing the #50 Sieve

5.3

2.00

5

4

4

4

4

4

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.28

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.28

0.47

1.28

1.18

1.28

1.06

1.22

1.07

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 56

99.7

82.7

Total Percent Passing the #4 Sieve

42.0

22.1

9.9Total Percent Passing the #50 Sieve

3.8

1.32

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.02

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.53

-0.55

-0.11

-0.54

-0.43

-0.69

-0.35

-0.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 58

99.8

86.4

Total Percent Passing the #4 Sieve

51.0

28.4

14.0Total Percent Passing the #50 Sieve

5.1

1.60

5

4

3

4

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.25

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.18

-0.21

1.45

1.61

1.50

1.42

1.01

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 59

100.0

84.2

Total Percent Passing the #4 Sieve

45.0

24.0

11.9Total Percent Passing the #50 Sieve

4.3

1.50

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.20

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.03

0.47

0.52

0.17

0.15

0.34

0.18

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 60

100.0

84.8

Total Percent Passing the #4 Sieve

47.9

26.4

13.3Total Percent Passing the #50 Sieve

5.3

2.07

5

5

5

5

4

4

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.31

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.37

0.47

0.77

0.87

0.88

1.06

1.22

1.18

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 61

99.9

76.6

Total Percent Passing the #4 Sieve

30.0

13.3

5.7Total Percent Passing the #50 Sieve

1.9

0.21

5

1

0

0

1

2

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

1Percent Loss by T11 (P200 Wash) 0.25

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-2.92

0.13

-2.69

-3.41

-3.12

-2.85

-2.33

-1.83

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 63

100.0

80.7

Total Percent Passing the #4 Sieve

42.2

21.4

9.5Total Percent Passing the #50 Sieve

2.8

0.10

5

5

5

5

5

4

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.20

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.03

0.47

-0.96

-0.50

-0.64

-0.89

-1.39

-2.00

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 64

99.9

84.2

Total Percent Passing the #4 Sieve

44.4

23.9

11.4Total Percent Passing the #50 Sieve

4.4

1.50

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.19

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.00

0.13

0.52

0.03

0.12

0.08

0.28

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 66

100.0

85.5

Total Percent Passing the #4 Sieve

50.6

29.4

14.5Total Percent Passing the #50 Sieve

5.3

1.82

5

4

3

3

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.48

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.90

0.47

1.07

1.51

1.80

1.68

1.22

0.78

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 69

100.0

84.2

Total Percent Passing the #4 Sieve

46.2

25.1

12.0Total Percent Passing the #50 Sieve

4.5

1.60

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.46

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.84

0.47

0.52

0.46

0.49

0.39

0.39

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 72

99.9

86.3

Total Percent Passing the #4 Sieve

51.1

28.7

14.2Total Percent Passing the #50 Sieve

5.3

1.62

5

4

3

3

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.52

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.02

0.13

1.41

1.63

1.59

1.52

1.22

0.45

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 73

99.9

85.8

Total Percent Passing the #4 Sieve

46.7

22.9

10.2Total Percent Passing the #50 Sieve

3.8

1.41

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.10

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.28

0.13

1.19

0.58

-0.19

-0.53

-0.35

0.11

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 74

100.0

86.1

Total Percent Passing the #4 Sieve

50.4

28.9

14.0Total Percent Passing the #50 Sieve

5.1

1.61

5

4

4

3

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 1.68

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.52

0.47

1.32

1.46

1.65

1.42

1.01

0.44

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 76

100.0

86.9

Total Percent Passing the #4 Sieve

50.4

30.2

16.0Total Percent Passing the #50 Sieve

5.9

1.90

5

3

4

2

2

3

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.58

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.21

0.47

1.66

1.46

2.05

2.45

1.85

0.91

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 77

100.0

84.5

Total Percent Passing the #4 Sieve

48.1

25.8

12.0Total Percent Passing the #50 Sieve

4.8

1.53

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.40

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.65

0.47

0.65

0.91

0.70

0.39

0.70

0.31

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 78

99.9

79.4

Total Percent Passing the #4 Sieve

40.2

20.6

10.1Total Percent Passing the #50 Sieve

3.7

1.25

5

3

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.25

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.18

0.13

-1.51

-0.97

-0.89

-0.58

-0.45

-0.14

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 79

99.9

81.8

Total Percent Passing the #4 Sieve

44.9

24.9

12.5Total Percent Passing the #50 Sieve

4.4

1.46

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.42

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.71

0.13

-0.49

0.15

0.43

0.65

0.28

0.20

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 80

100.0

84.8

Total Percent Passing the #4 Sieve

47.5

25.3

11.9Total Percent Passing the #50 Sieve

3.8

1.08

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.81

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.18

0.47

0.77

0.77

0.55

0.34

-0.35

-0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 81

99.9

84.5

Total Percent Passing the #4 Sieve

48.4

26.2

12.7Total Percent Passing the #50 Sieve

4.2

1.17

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.17

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.06

0.13

0.65

0.99

0.82

0.75

0.07

-0.27

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 82

100.0

85.4

Total Percent Passing the #4 Sieve

47.7

26.5

13.0Total Percent Passing the #50 Sieve

5.0

1.64

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.64

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.39

0.47

1.03

0.82

0.91

0.91

0.91

0.49

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 83

99.8

79.9

Total Percent Passing the #4 Sieve

38.2

18.8

8.6Total Percent Passing the #50 Sieve

2.6

0.03

5

4

4

4

4

3

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.24

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.15

-0.21

-1.30

-1.45

-1.44

-1.36

-1.60

-2.12

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 84

100.0

83.0

Total Percent Passing the #4 Sieve

43.8

22.1

9.7Total Percent Passing the #50 Sieve

3.3

1.17

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.08

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.34

0.47

0.01

-0.11

-0.43

-0.79

-0.87

-0.27

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 85

100.0

83.9

Total Percent Passing the #4 Sieve

46.8

25.7

12.5Total Percent Passing the #50 Sieve

4.8

1.60

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.46

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.84

0.47

0.39

0.60

0.67

0.65

0.70

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 86

100.0

85.8

Total Percent Passing the #4 Sieve

48.7

26.0

12.9Total Percent Passing the #50 Sieve

4.2

0.55

5

4

4

5

5

5

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

2Percent Loss by T11 (P200 Wash) 1.96

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

2.39

0.47

1.19

1.06

0.76

0.85

0.07

-1.28

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 87

99.9

80.1

Total Percent Passing the #4 Sieve

38.3

18.7

8.7Total Percent Passing the #50 Sieve

3.5

1.54

5

4

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.45

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.81

0.13

-1.21

-1.43

-1.47

-1.30

-0.66

0.32

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 88

100.0

87.7

Total Percent Passing the #4 Sieve

52.0

27.7

13.2Total Percent Passing the #50 Sieve

5.0

1.65

5

3

3

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.38

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.59

0.47

2.00

1.85

1.28

1.01

0.91

0.50

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 89

99.7

84.5

Total Percent Passing the #4 Sieve

49.2

26.7

12.7Total Percent Passing the #50 Sieve

4.3

2.61

5

5

4

5

5

5

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.31

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.37

-0.55

0.65

1.18

0.98

0.75

0.18

2.05

Total Percent Passing the 3/8" Sieve 99.7 99.97 0.21 -1.26 4

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 90

100.0

83.6

Total Percent Passing the #4 Sieve

46.3

26.9

13.9Total Percent Passing the #50 Sieve

5.5

1.70

5

5

5

4

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 1.68

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.52

0.47

0.27

0.48

1.04

1.37

1.43

0.58

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 91

100.0

81.7

Total Percent Passing the #4 Sieve

41.5

20.1

9.0Total Percent Passing the #50 Sieve

2.7

0.30

5

5

5

4

4

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.84

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.09

0.47

-0.54

-0.66

-1.04

-1.15

-1.49

-1.68

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 94

99.9

85.6

Total Percent Passing the #4 Sieve

48.3

26.9

13.2Total Percent Passing the #50 Sieve

4.9

1.60

5

4

5

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.33

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.43

0.13

1.11

0.96

1.04

1.01

0.80

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 95

100.0

83.8

Total Percent Passing the #4 Sieve

46.7

25.3

12.8Total Percent Passing the #50 Sieve

5.0

1.74

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.51

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.99

0.47

0.35

0.58

0.55

0.80

0.91

0.65

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 99

100.0

84.8

Total Percent Passing the #4 Sieve

46.1

25.1

12.2Total Percent Passing the #50 Sieve

4.8

1.82

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.47

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.87

0.47

0.77

0.44

0.49

0.49

0.70

0.78

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 100

99.8

86.6

Total Percent Passing the #4 Sieve

48.9

27.3

13.3Total Percent Passing the #50 Sieve

5.0

1.60

5

3

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.14

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.16

-0.21

1.53

1.11

1.16

1.06

0.91

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 102

100.0

80.4

Total Percent Passing the #4 Sieve

39.8

19.1

9.0Total Percent Passing the #50 Sieve

3.3

1.21

5

4

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.11

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.25

0.47

-1.08

-1.07

-1.35

-1.15

-0.87

-0.21

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 105

99.8

84.3

Total Percent Passing the #4 Sieve

47.0

25.3

12.1Total Percent Passing the #50 Sieve

4.6

1.63

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.50

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.96

-0.21

0.56

0.65

0.55

0.44

0.49

0.47

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 106

99.9

80.9

Total Percent Passing the #4 Sieve

40.8

20.7

9.4Total Percent Passing the #50 Sieve

3.5

1.28

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.22

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.09

0.13

-0.87

-0.83

-0.86

-0.94

-0.66

-0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 107

100.0

82.6

Total Percent Passing the #4 Sieve

47.7

25.4

12.2Total Percent Passing the #50 Sieve

3.6

0.46

5

5

5

5

5

5

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.20

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.03

0.47

-0.16

0.82

0.58

0.49

-0.55

-1.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 110

100.0

84.5

Total Percent Passing the #4 Sieve

45.9

24.2

10.9Total Percent Passing the #50 Sieve

3.9

1.26

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.23

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.12

0.47

0.65

0.39

0.21

-0.17

-0.24

-0.13

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 111

99.9

81.7

Total Percent Passing the #4 Sieve

41.8

21.9

10.4Total Percent Passing the #50 Sieve

4.0

1.60

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.11

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.25

0.13

-0.54

-0.59

-0.49

-0.43

-0.14

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 112

99.8

81.9

Total Percent Passing the #4 Sieve

41.9

21.2

10.0Total Percent Passing the #50 Sieve

3.8

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.99

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.62

-0.21

-0.45

-0.57

-0.71

-0.64

-0.35

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 113

99.9

78.9

Total Percent Passing the #4 Sieve

39.0

20.5

10.1Total Percent Passing the #50 Sieve

3.9

1.50

5

3

4

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.00

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.59

0.13

-1.72

-1.26

-0.92

-0.58

-0.24

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 115

99.8

79.4

Total Percent Passing the #4 Sieve

38.9

19.5

9.2Total Percent Passing the #50 Sieve

3.3

1.24

5

3

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.10

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.28

-0.21

-1.51

-1.28

-1.23

-1.05

-0.87

-0.16

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 116

99.9

85.2

Total Percent Passing the #4 Sieve

46.7

26.7

12.3Total Percent Passing the #50 Sieve

4.7

1.42

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.25

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.18

0.13

0.94

0.58

0.98

0.55

0.59

0.13

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 117

100.0

85.1

Total Percent Passing the #4 Sieve

49.2

26.9

13.6Total Percent Passing the #50 Sieve

4.8

1.65

5

5

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.03

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.50

0.47

0.90

1.18

1.04

1.21

0.70

0.50

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 118

99.8

84.2

Total Percent Passing the #4 Sieve

45.7

25.1

12.0Total Percent Passing the #50 Sieve

4.5

1.61

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.11

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.25

-0.21

0.52

0.34

0.49

0.39

0.39

0.44

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 119

99.9

85.6

Total Percent Passing the #4 Sieve

43.6

23.3

10.5Total Percent Passing the #50 Sieve

3.3

1.59

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.50

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.96

0.13

1.11

-0.16

-0.06

-0.38

-0.87

0.41

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 121

100.0

82.0

Total Percent Passing the #4 Sieve

41.0

22.0

11.0Total Percent Passing the #50 Sieve

4.0

1.00

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.91

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.87

0.47

-0.41

-0.78

-0.46

-0.12

-0.14

-0.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 122

99.9

82.1

Total Percent Passing the #4 Sieve

43.3

22.2

10.1Total Percent Passing the #50 Sieve

3.0

0.32

5

5

5

5

5

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.17

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.06

0.13

-0.37

-0.23

-0.40

-0.58

-1.18

-1.65

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 123

100.0

84.5

Total Percent Passing the #4 Sieve

44.4

22.4

10.1Total Percent Passing the #50 Sieve

3.3

0.52

5

5

5

5

5

5

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.22

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.09

0.47

0.65

0.03

-0.34

-0.58

-0.87

-1.32

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 124

99.9

83.4

Total Percent Passing the #4 Sieve

46.1

25.2

12.1Total Percent Passing the #50 Sieve

4.7

1.59

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.46

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.84

0.13

0.18

0.44

0.52

0.44

0.59

0.41

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 125

100.0

84.1

Total Percent Passing the #4 Sieve

47.3

27.6

15.0Total Percent Passing the #50 Sieve

5.5

1.89

5

5

5

4

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 1.80

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.89

0.47

0.48

0.72

1.25

1.93

1.43

0.89

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 127

100.0

80.0

Total Percent Passing the #4 Sieve

38.6

19.0

8.2Total Percent Passing the #50 Sieve

2.6

0.80

5

4

4

4

3

3

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 0.61

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.80

0.47

-1.25

-1.35

-1.38

-1.56

-1.60

-0.87

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 128

99.9

82.9

Total Percent Passing the #4 Sieve

40.7

19.5

8.9Total Percent Passing the #50 Sieve

3.2

1.30

5

5

5

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.10

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.28

0.13

-0.03

-0.85

-1.23

-1.20

-0.97

-0.06

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 129

99.9

82.0

Total Percent Passing the #4 Sieve

45.6

25.2

12.4Total Percent Passing the #50 Sieve

4.5

1.34

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.92

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.84

0.13

-0.41

0.32

0.52

0.60

0.39

0.00

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 130

100.0

81.8

Total Percent Passing the #4 Sieve

43.4

22.2

9.7Total Percent Passing the #50 Sieve

3.0

0.43

5

5

5

5

5

4

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.02

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.53

0.47

-0.49

-0.21

-0.40

-0.79

-1.18

-1.47

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 131

100.0

79.9

Total Percent Passing the #4 Sieve

39.2

20.6

10.0Total Percent Passing the #50 Sieve

3.9

1.42

5

4

4

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.97

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.68

0.47

-1.30

-1.21

-0.89

-0.64

-0.24

0.13

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 133

99.9

78.9

Total Percent Passing the #4 Sieve

36.8

17.6

8.5Total Percent Passing the #50 Sieve

3.2

1.20

5

3

3

3

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.97

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.68

0.13

-1.72

-1.78

-1.81

-1.41

-0.97

-0.23

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 136

100.0

80.0

Total Percent Passing the #4 Sieve

42.0

22.0

11.0Total Percent Passing the #50 Sieve

4.0

0.80

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.81

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.18

0.47

-1.25

-0.54

-0.46

-0.12

-0.14

-0.87

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 137

100.0

79.9

Total Percent Passing the #4 Sieve

39.0

18.8

8.5Total Percent Passing the #50 Sieve

3.3

1.31

5

4

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.86

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.03

0.47

-1.30

-1.26

-1.44

-1.41

-0.87

-0.05

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 138

100.0

77.7

Total Percent Passing the #4 Sieve

37.9

18.6

8.2Total Percent Passing the #50 Sieve

2.8

0.45

5

2

3

3

3

4

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.00

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.59

0.47

-2.22

-1.52

-1.50

-1.56

-1.39

-1.44

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 139

99.9

83.7

Total Percent Passing the #4 Sieve

45.6

24.7

11.3Total Percent Passing the #50 Sieve

4.1

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.38

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.59

0.13

0.31

0.32

0.36

0.03

-0.03

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 140

100.0

80.8

Total Percent Passing the #4 Sieve

40.5

20.8

9.7Total Percent Passing the #50 Sieve

3.7

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.12

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.22

0.47

-0.92

-0.90

-0.83

-0.79

-0.45

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 141

100.0

83.4

Total Percent Passing the #4 Sieve

45.5

24.1

12.4Total Percent Passing the #50 Sieve

4.7

1.60

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.22

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.09

0.47

0.18

0.29

0.18

0.60

0.59

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 142

99.9

84.0

Total Percent Passing the #4 Sieve

47.6

26.6

13.8Total Percent Passing the #50 Sieve

5.6

2.00

5

5

5

5

4

3

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

2Percent Loss by T11 (P200 Wash) 1.88

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

2.14

0.13

0.43

0.79

0.95

1.32

1.53

1.07

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 143

100.0

83.6

Total Percent Passing the #4 Sieve

43.5

21.2

8.9Total Percent Passing the #50 Sieve

2.8

0.30

5

5

5

5

4

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 0.70

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.52

0.47

0.27

-0.18

-0.71

-1.20

-1.39

-1.68

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 144

99.7

79.5

Total Percent Passing the #4 Sieve

34.4

18.4

8.7Total Percent Passing the #50 Sieve

2.8

0.31

5

4

2

3

4

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.89

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.93

-0.55

-1.46

-2.36

-1.56

-1.30

-1.39

-1.66

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 145

100.0

84.8

Total Percent Passing the #4 Sieve

49.5

27.9

13.4Total Percent Passing the #50 Sieve

4.9

1.62

5

5

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.03

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.50

0.47

0.77

1.25

1.34

1.11

0.80

0.45

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 146

99.7

82.9

Total Percent Passing the #4 Sieve

42.7

23.2

11.2Total Percent Passing the #50 Sieve

3.6

0.64

5

5

5

5

5

5

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.95

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.75

-0.55

-0.03

-0.38

-0.09

-0.02

-0.55

-1.13

Total Percent Passing the 3/8" Sieve 99.7 99.97 0.21 -1.26 4

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 147

99.9

82.3

Total Percent Passing the #4 Sieve

45.3

24.4

11.4Total Percent Passing the #50 Sieve

4.2

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.13

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.19

0.13

-0.28

0.25

0.27

0.08

0.07

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 148

100.0

82.6

Total Percent Passing the #4 Sieve

47.1

26.7

13.5Total Percent Passing the #50 Sieve

5.3

1.89

5

5

5

5

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.47

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.87

0.47

-0.16

0.68

0.98

1.16

1.22

0.89

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 149

99.9

81.6

Total Percent Passing the #4 Sieve

41.9

21.8

9.8Total Percent Passing the #50 Sieve

3.2

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.89

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.93

0.13

-0.58

-0.57

-0.52

-0.74

-0.97

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 150

99.9

85.2

Total Percent Passing the #4 Sieve

47.6

25.7

13.3Total Percent Passing the #50 Sieve

5.1

0.16

5

5

5

5

4

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.14

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.16

0.13

0.94

0.79

0.67

1.06

1.01

-1.91

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 152

99.9

84.4

Total Percent Passing the #4 Sieve

45.4

23.9

10.8Total Percent Passing the #50 Sieve

3.9

1.36

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.71

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.49

0.13

0.60

0.27

0.12

-0.22

-0.24

0.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 153

100.0

85.4

Total Percent Passing the #4 Sieve

47.2

26.6

13.2Total Percent Passing the #50 Sieve

5.4

1.80

5

4

5

5

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

3Percent Loss by T11 (P200 Wash) 1.75

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.74

0.47

1.03

0.70

0.95

1.01

1.32

0.74

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 154

99.9

81.0

Total Percent Passing the #4 Sieve

40.9

20.1

8.6Total Percent Passing the #50 Sieve

3.1

1.30

5

5

5

4

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.05

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.44

0.13

-0.83

-0.81

-1.04

-1.36

-1.08

-0.06

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 156

99.7

80.5

Total Percent Passing the #4 Sieve

41.6

21.6

9.6Total Percent Passing the #50 Sieve

3.5

1.32

5

4

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.24

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.15

-0.55

-1.04

-0.64

-0.58

-0.84

-0.66

-0.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 157

99.9

80.9

Total Percent Passing the #4 Sieve

42.9

22.0

10.6Total Percent Passing the #50 Sieve

4.1

1.60

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.00

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.59

0.13

-0.87

-0.33

-0.46

-0.33

-0.03

0.42

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 158

99.8

82.0

Total Percent Passing the #4 Sieve

43.9

23.5

11.2Total Percent Passing the #50 Sieve

4.4

1.30

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.95

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.75

-0.21

-0.41

-0.09

0.00

-0.02

0.28

-0.06

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 159

99.9

83.3

Total Percent Passing the #4 Sieve

46.6

25.2

12.4Total Percent Passing the #50 Sieve

4.6

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.10

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.28

0.13

0.14

0.56

0.52

0.60

0.49

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 160

100.0

85.1

Total Percent Passing the #4 Sieve

46.5

25.6

12.1Total Percent Passing the #50 Sieve

4.4

1.46

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.36

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.53

0.47

0.90

0.53

0.64

0.44

0.28

0.20

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 161

100.0

85.4

Total Percent Passing the #4 Sieve

48.8

26.8

13.2Total Percent Passing the #50 Sieve

5.0

1.50

5

4

4

4

4

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.41

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.68

0.47

1.03

1.08

1.01

1.01

0.91

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 162

99.8

83.6

Total Percent Passing the #4 Sieve

42.8

21.2

9.9Total Percent Passing the #50 Sieve

3.5

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.11

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.25

-0.21

0.27

-0.35

-0.71

-0.69

-0.66

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 164

99.9

83.2

Total Percent Passing the #4 Sieve

45.3

24.4

12.4Total Percent Passing the #50 Sieve

4.9

1.58

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.38

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.59

0.13

0.10

0.25

0.27

0.60

0.80

0.39

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 165

100.0

86.2

Total Percent Passing the #4 Sieve

52.1

31.4

16.3Total Percent Passing the #50 Sieve

6.7

2.38

5

4

3

2

1

1

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

0Percent Loss by T11 (P200 Wash) 2.22

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

3.19

0.47

1.36

1.87

2.41

2.60

2.68

1.68

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 166

99.9

85.4

Total Percent Passing the #4 Sieve

47.8

24.4

12.0Total Percent Passing the #50 Sieve

5.1

2.30

5

4

5

5

5

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.29

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.31

0.13

1.03

0.84

0.27

0.39

1.01

1.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 169

99.9

83.0

Total Percent Passing the #4 Sieve

47.0

27.0

13.3Total Percent Passing the #50 Sieve

5.3

1.74

5

5

5

4

4

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.21

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.06

0.13

0.01

0.65

1.07

1.06

1.22

0.65

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 172

99.9

80.7

Total Percent Passing the #4 Sieve

42.4

22.2

9.7Total Percent Passing the #50 Sieve

2.9

0.30

5

5

5

5

5

4

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.52

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.02

0.13

-0.96

-0.45

-0.40

-0.79

-1.28

-1.68

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 174

99.7

80.7

Total Percent Passing the #4 Sieve

40.2

19.7

8.3Total Percent Passing the #50 Sieve

2.8

1.00

5

5

5

4

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.72

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.46

-0.55

-0.96

-0.97

-1.16

-1.51

-1.39

-0.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 176

100.0

83.7

Total Percent Passing the #4 Sieve

37.3

20.5

12.6Total Percent Passing the #50 Sieve

8.1

3.43

5

5

3

5

5

0

0

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.36

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.53

0.47

0.31

-1.67

-0.92

0.70

4.14

3.38

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 178

99.9

85.0

Total Percent Passing the #4 Sieve

46.3

25.8

12.3Total Percent Passing the #50 Sieve

4.6

1.56

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.33

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.43

0.13

0.86

0.48

0.70

0.55

0.49

0.36

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 179

99.9

83.3

Total Percent Passing the #4 Sieve

43.1

22.1

10.7Total Percent Passing the #50 Sieve

4.4

1.90

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.62

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.33

0.13

0.14

-0.28

-0.43

-0.28

0.28

0.91

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 180

99.8

82.8

Total Percent Passing the #4 Sieve

44.2

23.8

11.7Total Percent Passing the #50 Sieve

4.2

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.32

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.40

-0.21

-0.07

-0.02

0.09

0.24

0.07

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 181

100.0

85.0

Total Percent Passing the #4 Sieve

47.7

26.4

12.9Total Percent Passing the #50 Sieve

4.8

1.50

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.10

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.28

0.47

0.86

0.82

0.88

0.85

0.70

0.26

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 182

100.0

80.5

Total Percent Passing the #4 Sieve

40.8

18.9

8.2Total Percent Passing the #50 Sieve

2.9

1.09

5

4

5

4

3

4

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.96

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.72

0.47

-1.04

-0.83

-1.41

-1.56

-1.28

-0.40

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 185

100.0

82.1

Total Percent Passing the #4 Sieve

43.6

23.1

11.2Total Percent Passing the #50 Sieve

4.1

1.00

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.26

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.22

0.47

-0.37

-0.16

-0.13

-0.02

-0.03

-0.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 186

100.0

86.5

Total Percent Passing the #4 Sieve

46.6

25.3

10.2Total Percent Passing the #50 Sieve

2.9

0.70

5

4

5

5

5

4

4

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.37

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.56

0.47

1.49

0.56

0.55

-0.53

-1.28

-1.03

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 187

99.9

80.7

Total Percent Passing the #4 Sieve

43.1

22.8

10.9Total Percent Passing the #50 Sieve

4.3

1.69

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 0.87

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-0.99

0.13

-0.96

-0.28

-0.22

-0.17

0.18

0.57

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 189

99.9

84.0

Total Percent Passing the #4 Sieve

44.0

22.6

11.3Total Percent Passing the #50 Sieve

4.5

1.70

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.30

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.34

0.13

0.43

-0.07

-0.28

0.03

0.39

0.58

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 190

98.4

78.3

Total Percent Passing the #4 Sieve

38.3

18.8

8.7Total Percent Passing the #50 Sieve

2.6

0.10

0

3

4

4

4

3

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.39

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.62

-4.99

-1.97

-1.43

-1.44

-1.30

-1.60

-2.00

Total Percent Passing the 3/8" Sieve 98.6 99.97 0.21 -6.46 0

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 191

99.6

80.9

Total Percent Passing the #4 Sieve

43.0

22.2

10.5Total Percent Passing the #50 Sieve

3.8

1.37

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.27

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.25

-0.89

-0.87

-0.30

-0.40

-0.38

-0.35

0.05

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 193

99.9

83.4

Total Percent Passing the #4 Sieve

40.8

19.9

8.5Total Percent Passing the #50 Sieve

2.8

0.10

5

5

5

4

4

4

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 0.80

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-1.21

0.13

0.18

-0.83

-1.10

-1.41

-1.39

-2.00

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 194

99.9

83.3

Total Percent Passing the #4 Sieve

45.3

24.2

11.8Total Percent Passing the #50 Sieve

4.3

1.40

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.21

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.06

0.13

0.14

0.25

0.21

0.29

0.18

0.10

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 196

100.0

84.3

Total Percent Passing the #4 Sieve

48.2

25.4

12.3Total Percent Passing the #50 Sieve

4.6

1.52

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.41

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.68

0.47

0.56

0.94

0.58

0.55

0.49

0.29

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 197

99.9

81.9

Total Percent Passing the #4 Sieve

42.0

20.8

9.3Total Percent Passing the #50 Sieve

3.4

0.82

5

5

5

5

5

5

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

2Percent Loss by T11 (P200 Wash) 0.48

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-2.21

0.13

-0.45

-0.54

-0.83

-1.00

-0.76

-0.84

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 199

99.9

84.2

Total Percent Passing the #4 Sieve

45.7

23.0

10.4Total Percent Passing the #50 Sieve

3.0

0.10

5

5

5

5

5

4

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.43

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.74

0.13

0.52

0.34

-0.16

-0.43

-1.18

-2.00

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 200

98.6

84.5

Total Percent Passing the #4 Sieve

50.0

26.9

12.2Total Percent Passing the #50 Sieve

3.3

0.10

0

5

4

4

5

5

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

5Percent Loss by T11 (P200 Wash) 1.44

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

0.77

-4.31

0.65

1.37

1.04

0.49

-0.87

-2.00

Total Percent Passing the 3/8" Sieve 98.6 99.97 0.21 -6.46 0

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 201

98.3

82.5

Total Percent Passing the #4 Sieve

45.7

23.9

11.0Total Percent Passing the #50 Sieve

3.2

0.10

0

5

5

5

5

5

2

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

4Percent Loss by T11 (P200 Wash) 1.61

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

1.30

-5.33

-0.20

0.34

0.12

-0.12

-0.97

-2.00

Total Percent Passing the 3/8" Sieve 98.4 99.97 0.21 -7.40 0

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 202

100.0

77.5

Total Percent Passing the #4 Sieve

33.1

15.3

7.3Total Percent Passing the #50 Sieve

2.5

1.00

5

2

1

1

2

3

5

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

2Percent Loss by T11 (P200 Wash) 0.40

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-2.45

0.47

-2.31

-2.67

-2.51

-2.02

-1.70

-0.55

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

2020 Fine Aggregate Round Robin Report

Lab Number 203

99.9

83.8

Total Percent Passing the #4 Sieve

45.1

24.3

11.2Total Percent Passing the #50 Sieve

4.2

2.27

5

5

5

5

5

5

3

Total Percent Passing the #8 Sieve

Total Percent Passing the #16 Sieve

Total Percent Passing the #30 Sieve

Total Percent Passing the #100 Sieve

Total Percent Passing the #200 Sieve

Ratings Lab Results

1.19

Average

99.86

82.97

44.27

1Percent Loss by T11 (P200 Wash) 0.24

23.51

11.24

4.13

1.34

0.32

0.29

2.37

4.19

3.27

1.95

0.96

0.62

PopStdDev Z Score

-2.95

0.13

0.35

0.20

0.24

-0.02

0.07

1.50

Total Percent Passing the 3/8" Sieve 100 99.97 0.21 0.16 5

Rating = 5 corresponds to Z scores no greater than 1.0

Rating = 4 corresponds to Z scores greater than 1.0 but less than or equal to 1.5

Rating = 3 corresponds to Z scores greater than 1.5 but less than or equal to 2.0

Rating = 2 corresponds to Z scores greater than 2.0 but less than or equal to 2.5

Rating = 1 corresponds to Z scores greater than 2.5 but less than or equal to 3.0

Rating = 0 corresponds to Z scores greater than 3.0

If any of the individual results are less than or equal to a rating of 2, perform a brief labortory investigation in an attempt to document the potential

cause of this low rating (e.g. calculation error, equipment, or procedural). The documented results of this investigation should then be put on file in

the laboratory and kept for a period of no less than five years. This documentation should be made available to ODOT upon request. If any of the

individual results are less than or equal to a rating of 1 then the results of a completed laboratory investigation and copy of all calculations should be

immediately submitted to the OMM Aggregate Section. Detailed instructions regarding deadlines and other follow up instructions will be emailed to

these labs. If requested please submit all follow up documentation to: aggregate.S1069.documents@dot.ohio.gov, or by mail to: OMM Aggregate

Section at 1600 W. Broad St., Columbus, Ohio 43213. Failure to respond in a timely manner may result in loss of S1069 laboratory and associated

producer/supplier prequalification.

The 2020 Round Robin study included a total of 146 participating laboratories. Each participating laboratory's results were entered into a combined

database and analyzed for basic statisics. This report displays the individual lab results submitted to the OMM Aggregate Section, the population

average, population standard deviation, Z score, and rating. The Z score indicates how many standard deviations away from the population average

each reported result is. Each rating is based upon a corresponding Z score range described below:

top related