12:00

PROJECT

LOCATION/TYPE

Lig

ht

ing

Co

nt

ro

L P

an

eL

Sy

St

em

S

www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5

LI Complete Control Level Interior (LIC8, LIC24, LIC48, LICA8, LICA24, LICA48)

Complete scheduling, monitoring, and reporting capabilities via exclusive WinControl software

Priority array based logic engine for simple execution of complex control scenarios

• Networkupto500panelsviaopentopologydigitaldatabus

• CreateuserprogrammingofflineusingWinControlsoftwareandtransfertopanels

• ImportsitedocumentationfromWinControlDesignerprojectdesignanddocumentationsoftware

• Programmablegroupcodeswithscenariobasedlogicprovidesystem-widecontrol

• PowerfuldataloggingfeaturewithmanualandautomaticlogtransfertoPC

•OptionforseamlessbuildingsystemintegrationusingBACnetprotocol

• SupportsWattStopperoccupancysensorsdirectlywithoutpowerpacks

TheWattStopperLightingIntegratorCompleteControl(LIC)systemisafullfeaturednetworkedcontrolsystemthatprovidesthemaximumflex-ibilityforlightingcontrolbyprovidingbothpanelbasedanddistributedloadcontroloptions.Adigitalcommunicationbusallowsuserprogram-minggeneratedattheWinControlworkstationtobetransferredtothepanelswhereitrunsautonomously.Onceloadedintothepanels,thelightingautomationfeaturesoperatewithouttheneedforanonlinePC.Thisdistributedprocessingcapabilityensuresahighdegreeofreliability.LICincorporatesallthebasefeaturesoftheLightingIntegratorhardwareplatformincludingtheHDRmechanicallylatching,heavydutyrelay.

LICApanels,withlocaldatalinesupport,providelocalDatalineSwitchfunctionality.

OperationDescriptionProduct Overview

Features • GeneratedetaileddocumentationreportsofallaspectsofsystemhardwareandsoftwareviaWinControlsoftware

• Programmableanaloginputsprovidemultiplesetpointsforphotocellsorotheranalogdevices

• Programmabledatalineswitchesconnecttopanelwith4wireopentopologydigitaldatabus

• ProvidesfullsupportforWattStopperASseriesAutomaticWallSwitch

• RemotenetworksupervisionandprogrammingviaTCP/IPconnectionusingoptionalWebLinkdevice

• QualifiesforuseonARRA-fundedprojects

Compatible with legacy Complete Control systems

Distributed processing architecture with robust 2-wire digital network communications

EachLICpanelstorestheusergeneratedpro-gramminginnonvolatilememoryhousedwithintheCompleteControlintelligencecard.Thiscontrollermonitorsallinputsandusesauniquepriorityarraybasedlogicenginetogeneratetheappropriateloadresponse(relaycontrol)basedonsimpleorcomplexcombinationsofinputtrig-gersthatcanincludeschedules,overrideswitches,occupancysensors,photocellsandsignalsfromotherbuildingsystems.

LICfeaturesalibraryofscenariobasedcontrolschemesthatprovidepowerfulcontroloptionswithoutthecomplexityoflowleveluserprogram-ming.Thesecontrolscenariosincludeprovisionsforcommonarealogicwithegress,cleaningcrewoverrides,loadshed,forceon,forceoff,blinkwarn,andafterhourtimedelay.

Syste

m&

Enclo

sures

12:00

Lig

ht

ing

Co

nt

ro

L P

an

eL

Sy

St

em

S

www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5

Syste

m&

Enclo

sures

LIC System Layout

LIC Specifications

• Panelconfigurationsprovide8,24,or48relaysizeinteriors

• Standardrelay,individuallyreplaceableWattStopperHDRseries,latchingSPST,meetsnewNEMAelectronicballastrequire-ments,14,000AmpsSCCR,withintegralmanualoverride

• Digitalnetworkdataline,onepairtwistedandshielded,opentopologyallowslinear,star,andTnetworkconfigurationsforpanels/con-nectivity4000’maxlength

• NetworklinkdeviceprovidesRS-232connec-tiontodigitaldatalineforPCorWebLinkandvisualindicationofsystemoperation

• Analoginput,12VDCsourceprovided,0–4VDCinput,8inputsprovidedpergroupswitchingcard

• Optionallocaldataline,twopairtwisted,opentopologyallowslinear,star,andTconfigu-rations,63HDLSseriesswitchaddressesavailableperdataline,1500’maxlength(LICAoption)

• Analogsetpoints,32maximumperpanel,highset/lowsetwithindividualhigh/lowtimedelays

• Directwireswitchinputs,oneeachperrelayandgroupswitchchannel,automaticallycon-figureforoccupancysensoroperation

• Pilotlightoutputperrelayandgroupswitchchannel,configurableforanyClass2voltage

• DINrailmountingforautomationmodules

• ULlisted,oneyearwarranty

Panel System Layout and Configuration

Local Dataline (4-wire)

OccupancySensor

Analogphotocell

DatalinePower Supply

CompleteControl Cards

Global dataline (2-wire)

DataComunications

link

LIC LIC LICA

Dataline Switches

WinControlPC

OptionalLocalDataline

Note:Datalinepowersupplyrequiredinonepanelonly.

12:00

Lig

ht

ing

Co

nt

ro

L P

an

eL

Sy

St

em

S

www.wattstopper.com8 0 0 . 8 7 9 . 8 5 8 5

WattStopper’sLightingIntegrator(LI)isalowvoltage,relaybasedlightingcontrolpanel.Panelinteriorsareconfiguredas8,24or48relaycapacitywiththequantityofrelaysinstalledascalledforontheorder.Theinteriormountsintotheappropriateenclosure.TheLIpanelenclosureandcoverareshippedseparatelyfromthepanelinteriortofacilitateprojectrough-inrequirements. Group Switching

Description

Groupswitching,alsoreferredtoasSmartwiredswitching,isasimplebuttonpressinterfacethatallowsanyquantityofrelaysinapaneltobeassignedquicklytoeachgroupswitchingchannelforcommonon/offcontrolorforpattern(scene)control.Eachoftheeightchannelsisprovidedwithanoverridepushbutton,LEDstatusindicatorandterminalsforconnectionofwallswitchesandoccupancysensors.Aneightor24sizepanelcanbeorderedwithonegroupswitchcard(8channels),48sizepanelscanhavetwogroupswitchcardsforatotalof16channels(8controllablebyscheduling,eightbyswitchingonly).

Operation

LIrelaysaredriventoalatchedonoroffpositionviaa24voltDCpulsegeneratedbytherelaydrivercards.Amomentarypushbuttonisprovidedforeachrelaytomanuallytoggletherelay’sstatewitheachbuttonpress.Anisolatedcontactintherelaysprovidespositivestatusfeedbacktotherelaydrivercircuits,whichareannunciatedbyanLEDassociatedwitheachrelay.Removableterminalblocksallowconnectionofdirectwiredlowvoltagedevicesforremotecontrolofrelays.

Inputscanbewiredtoaccommodatemaintainedormomentarythreewireortwowireinputs.TheswitchinputcircuitsareautosensingandwillautomaticallyconfigureappropriatelywhenWattStopperoccupancysensorsareconnected.

Operation (cont’d.)General LI Information

Syste

m&

Enclo

sures

• InteriorprovidescompleteisolationbetweenlineandlowvoltagewhenusedwithanLIenclosure(LENC)

• Individualplug-in,latchingstylesinglepoleHDRrelayswithisolatedpilot/statuscontacts

• Integralpushbuttonoverride,statusLED,andpilotlightoutputperrelay

• Twoslotsavailableforoptionalautomation,networkingandintegrationcontrolcards

• SupportsWattStopperlowvoltageoccupancysensorswithoutneedforseparatesensorpowerpacks

• Smartwiringfeatureallowsgroupingofrelaysforcommoncontrol

• DINrailmountingprovidedwithintheClass2sectionformountingofoptionalaccessories

• Controlmulti-polecircuitswithoptionalcontactorsandcompatibleLENCenclosure

• Optionalconfigurationavailableforuseonemergencylightingcircuits

12:00

Lig

ht

ing

Co

nt

ro

L P

an

eL

Sy

St

em

S

www.wattstopper.com | 8 0 0 . 8 7 9 . 8 5 8 5

Panel Interior Dimensions

General LI Specifications

• Interiorcapacity:

-8SPSTrelays

-24SPSTrelays

-48SPSTrelays

• Inputvoltageoptions,120/277V60Hz,120/347V60Hz,240V50Hz

• Groupswitching,eightchannelsperinstalledgroupswitchingcard.OnecardmaxperLI8andLI24.TwocardsmaxLI48.

• Lowvoltageswitchinputs,removableterminalblockswithtool-lessconnection,configurableforthreewiremomentary,twowiremomentary(toggle),andtwowiremaintaineddrycontactswitchesorWattStopperoccupancysensors.

•Accessorypoweravailable

-LI8:1000MA@24VACor800MA@24VDC

-LI24andLI48:1400MA@24VACor800MA@ 24VDC

•SCCR(shortcircuitcurrentrating)14,000ampswithHDRHeavyDutyRelay

•HDRSPSTrelays:

-Coilvoltage,24VDC,pulseONandpulseOFF

-Mechanicallylatchedcontacts

-½”K,O,mounting,LVplug-connection,individuallyreplaceable

-Contactratings 30ampsballast@277V 20ampsballast@347V 20ampstungsten@120V 30ampsresistive@347V 1.5HP@120V -Endurance:300,000mechanicalcycles

• Pilotlightoutput,24Vrectifiedor24VAC,othervoltagesconfigurablewithexternalpowersupply

• Oneyearwarranty

Ordering Information

CapacityVoltageOptionsRelayCountGroupSwitchCardEmergencyRelaysCoilVoltageDatalinePowerSupply

115/277

115/347

240

LIC8

LIC24

LIC48

LICA8

LICA24

LICA48

___HDRrelaysinstalled(maxofinteriorcapacity)

___GScards(max1in8,24,2in48)

115

240

277

347

InstalledOptions

Pub.No.21906rev.5/2013

10.5"26.67 cm

23.37"59.37 cm

13"33.02 cm

14"35.56 cm

14"35.56 cm

8 relayinterior capacity

24 relayinterior capacity

48 relayinterior capacity

35.75"90.80 cm

Syste

m&

Enclo

sures

___EMrelaycount(Notavailablein8-relaysizepanels;max.of24in24-relayor48-relaysizeinterior)

Interior

___DPdatalinepowersupply(onerequiredpereachnetwork)

top related