patient visibility

Post on 21-Jan-2016

52 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

DESCRIPTION

Group IV. Patient Visibility. Ann Rogers Kushal Waghmare Wanlin Xiang. Patient Visibility What and Why?. Monitoring Noting changes in state Preventing falls Preventing suicide Verifying alarm falsity/veracity Improved workflow - PowerPoint PPT Presentation

TRANSCRIPT

Patient Visibility

Ann Rogers Kushal Waghmare Wanlin Xiang

Group IV

Patient Visibility What and Why?

– Monitoring • Noting changes in state• Preventing falls• Preventing suicide• Verifying alarm falsity/veracity

– Improved workflow• Remembering patient conditions (out of sight, out of mind)• Toyota Lean Principles

Physical sightlines between patient and care staff (Open doors and blinds; Adequate lighting)

Visibility Analysis

– No. of unique points visible from a particular point– Visibility Plots– Generic Visibility vs. Target Visibility

Visibility can be measured/calculated mathematically

Spatial Positioning Tool

– Measures visual relationship among selected positions

– Isovist = (2d polygon – shadow space)– I/P file is a dxf file which contains 2d information

Markhede and Carranza proposed an isovist based automated model developed in Java

Current Configurations

Parallel Corridor Open/Closed Surrounded

Off Beds

Spokes, No End Station

Spokes With End Station Embedded U-Shaped

Visibility -> “Visibility”Physical proximity to patients = better than direct

sightlines – HKS Study:

• Increased socialization, mentoring, consulting

– In class: Empathy and Rapid assessments• Smell, Hearing

Outboard Inboard

ObservationsMortality rates of High-Visibility vs. Low-Visibility Rooms

– Mortality rates (HVR) < Mortality rates (LVR)– Especially in Cardiac Arrests and Respiratory

Issues– Patients have very little time to recover

NICU and PICUNeonatal & Pediatric ICUs

– More vigilant, careful monitoring required– Signals indicating change in medical conditions are

very subtle– NICUs should provide good visibility to infants– Control stations: within close proximity and direct

visibility of newborn care area. – Incubators should be transparent from at least 3

sides to allow maximum visibility

When a re-design isn’t possible

• Higher nurse to patient ratio

• Minimize peer-to-peer relationships among nurses with decentralized nursing stations

• Place sickest patients in most visible rooms

DOs Position of the headwall canted toward corridor view window Room has a provision for a computer and supplies storage Standardized room size, layout Charting alcove with window Appropriate lighting

St Joseph’s Hospital, St Paul, Minnesota

DON’Ts

• Small windows• Centralized nursing stations• Closed private rooms with more privacy• Presence of blind spots• Improper alignment of beds• Large unit sizes with poor sightlines

top related