On line Energy conservation System
13 May,2010
K.R. NerkarGM ( Electrical)
-
8/10/2019 REL EMSModifiedl
2/47
confidential
Content
Introduction
Aux power at DTPS
Aux power reduction Strategy
EMS at DTPS
Application
Benefits
-
8/10/2019 REL EMSModifiedl
3/47
confidential
Largest integrated private utility company in power sector
Involved in generation, transmission, distribution, trading of electricity and
EPC business related to power projects
Supplies electricity to 2 out of 3 Mumbai consumers and 1 out of 2 Delhi
consumers
Caters to 25 million people in Mumbai, Delhi and Orissa.
Distributes > 28 Billion units of electricity .
Generate > 900 MW of power.
Company Profile Reliance Energy Limited
-
8/10/2019 REL EMSModifiedl
4/47
confidential
DTPS Vision
To be amongst the world class power plants, delivering reliable
generation of electricity at competitive costs, with international
standards of environmental emission.
To set new benchmarks in standards of performance through the
pursuit ofoperational and financial excellence.
-
8/10/2019 REL EMSModifiedl
5/47
confidential
DTPS Mission
Attain global best practices and become a world-class power plant.
Provide affordable, reliable and clean powerto millions of customers.
Achieve excellence in service, quality, reliability, safety and customer care.
Work with vigor, dedication and innovation with total customer satisfaction
as the ultimate goal.
Consistently achieve high growth with the highest levels of productivity.
Be a technology driven, efficient and financially sound organization.
Promote a work culture that fosters individual growth, team spirit and
creativity to overcome challenges and attain goals. Encourage ideas, talent and value systems.
Uphold the guiding principles of trust, integrity and transparency in all
aspects of interactions and dealings.
Excellence in Generation of Electricity to :
-
8/10/2019 REL EMSModifiedl
6/47
confidential
Total Plant Generation 520MW
Auxiliary Power consumption 39.5MW@7.6%
HT Motor consumption 37.50MW
LT Motor consumption 1.50MW
Misc. consumption 0.50MW
Auxiliary power consumption at DTPS
-
8/10/2019 REL EMSModifiedl
7/47confidential
Aux. Power consumption reduction strategy
DTPS having 16 no's Energy auditors.
DTPS O&M has internal energy audit schedule through system.
Joint Energy auditing carried out for all utilities by CII & DTPS
Recommendations out of audit report are reviewed monthly.
Measure Detect Control
-
8/10/2019 REL EMSModifiedl
8/47confidential
On Line EMS at
DTPS
-
8/10/2019 REL EMSModifiedl
9/47confidential
Objective Of EMS
Online monitoring of auxiliary wise energy consumption.
To optimize the power consumption.
Benchmarking energy consumption
To identify the inefficient equipment operation
To provide useful input for Predictive maintenance decisions
The main objectives of EMS are :
-
8/10/2019 REL EMSModifiedl
10/47confidential
Components of EMS system
Energy meter class 1 model -6400 (135)
Analog card for the process parameters
Data converter
Communication cable
Dedicated PC and printer
Conzerve Energy management software eLAN customized to DTPS.
-
8/10/2019 REL EMSModifiedl
11/47confidential
Network Connectivity
eLAN
DATACONVERTOR
DATA
CONVERTOR
EM-6400 MULTIFUNCTION METERS
-
8/10/2019 REL EMSModifiedl
12/47confidential
Network Connectivity
ELAN
SERVER
PCR-2 Back Up Desk
24 channel
Process Scanner
PSC-2
Panel CWA-12
OSC
OSD 2SC
2SB
2SA
2PA
OPB
CABLE-5
RS485
RS485 RS485
8 PORT PCI
RS485 to RS232converter
CABLE-6
CABLE-4
ELAN Network Connectivity:
-
8/10/2019 REL EMSModifiedl
13/47confidential
Network ConnectivityPCR-1 PCR-2
4-20 mA 4-20 mA
ELAN
SERVER
6.6 KV Swgr
U-1
6.6 KV Swgr
U-2
RS485RS485
ELAN
VIEW
ELAN
VIEW
LAN
Single Login
Process parameter Process parameter
RS485RS485
FGD
Process parameter
SCANNER
4-20 mA
Compressor
RoomProcess parameter
SCANNER
4-20 mA
RS485
SCANNER SCANNER
RS485
24+16 channel 24+16 channel
16 channel16 channel
-
8/10/2019 REL EMSModifiedl
14/47confidential
Display Available
Home page
Mimic : Can view individual equipment parameters.
Matrix : Group of equipment Swgr wise, application wise can be viewed.
Trends : This Screen shows of real time data of every individual feeder
Dashboard : At a glance provide the data regarding lighting, HVAC etc.
History :To monitor trend of the all feeder with selected parameters and time.
Alarm : Initiate the alarm when the value cross the max. or min. value.
Reports: Hourly, daily, monthly consumption report are available.
SLD : Single line diagram with parameters can be viewed.
-
8/10/2019 REL EMSModifiedl
15/47confidential1515
Home page
-
8/10/2019 REL EMSModifiedl
16/47confidential16
Mimic.
-
8/10/2019 REL EMSModifiedl
17/47
confidential17
Matrix
-
8/10/2019 REL EMSModifiedl
18/47
confidential18
-
8/10/2019 REL EMSModifiedl
19/47
confidential19
-
8/10/2019 REL EMSModifiedl
20/47
confidential20
Trends
-
8/10/2019 REL EMSModifiedl
21/47
confidential21
This Screen shows Trend (of real time data of every individual feeder (Flow, pressure, Active power).
-
8/10/2019 REL EMSModifiedl
22/47
confidential22
Dashboard
-
8/10/2019 REL EMSModifiedl
23/47
confidential23
History
-
8/10/2019 REL EMSModifiedl
24/47
confidential24
History
-
8/10/2019 REL EMSModifiedl
25/47
confidential25
History
-
8/10/2019 REL EMSModifiedl
26/47
confidential26
Trend history
for one month
History
-
8/10/2019 REL EMSModifiedl
27/47
confidential27
Alarm
-
8/10/2019 REL EMSModifiedl
28/47
confidential28
Reports
-
8/10/2019 REL EMSModifiedl
29/47
confidential29
SLD
-
8/10/2019 REL EMSModifiedl
30/47
confidential30
View Reports
Feeder name
-
8/10/2019 REL EMSModifiedl
31/47
confidential31
Utility
-
8/10/2019 REL EMSModifiedl
32/47
confidential
Application
Electrical parameters like
Current,
Voltage,
Power
Freq.
Power factor
KWH
Process parameters like flow ,pressure etc
Specific energy consumption and comparison
Historical data equipment wise.
A. Data Monitoring
http://localhost/var/www/apps/conversion/tmp/scratch_4/Daily%20Energy%20Deviation%20Report-11-MAY-2010.pdfhttp://localhost/var/www/apps/conversion/tmp/scratch_4/Daily%20Energy%20Deviation%20Report-11-MAY-2010.pdf -
8/10/2019 REL EMSModifiedl
33/47
confidential33
-
8/10/2019 REL EMSModifiedl
34/47
confidential34
-
8/10/2019 REL EMSModifiedl
35/47
confidential35
-
8/10/2019 REL EMSModifiedl
36/47
confidential
1 .Scheduled operation
Daily Auxiliary load profile helps to reschedule the changeover operation
Ex. Mill changeover, BFP changeover by comparing power consumption.
Priority base scheduling peak/off-peak hours
Ex. operating the coal bunkering, Hydrogen/ DM plant during off-peak hours.
2. Enhancing the efficient operation by
Identifying the inefficient equipment.
Operating the most efficient equipment comparing the power consumption.
B. Strategy for operation of equipment
Application
-
8/10/2019 REL EMSModifiedl
37/47
confidential37
0.00
500.00
1000.00
1500.00
2000.00
2500.00
3000.00
3500.00
4000.00
4500.00
5000.00
5500.00
6000.00
6500.00
7000.00
7500.00
8000.00
KW
Date
Unit - 1 BFP 1A/1B Daywise energy consumptionBFP # 1A
BFP # 1B
252 KW /hr &
Around 55000 unit saved
Case :1
-
8/10/2019 REL EMSModifiedl
38/47
confidential38
Case :2
0.00
100.00200.00
300.00
400.00
500.00
600.00
700.00
800.00
900.00
1000.00
1100.00
1200.00
1300.00
1400.00
1500.00
KW
Date
Unit-1 Mill 1AB/1CD/1EF Daily consumption
Mill # 1AB
Mill # 1CD
Mill # 1EF
Around 150 KW /hr saving done during this month.
( 94173 units )
-
8/10/2019 REL EMSModifiedl
39/47
confidential39
Benefits
Elimination of human error in measurement
Benchmarking energy consumption
Different type of reports like daily, monthly, quarterly or yearly can be
generated automatically.
Enhanced the efficient equipment operation
Useful Data available for Predictive maintenance decision.
Availability of online data of all electrical and process at single point which
is very useful for Energy audit.
Measurement and verification
-
8/10/2019 REL EMSModifiedl
40/47
Thank you
-
8/10/2019 REL EMSModifiedl
41/47
confidential41
Predictive maintenance
18
19
13
12
0
2
4
6
8
10
12
14
16
18
20
Unit 1 Unit 2
Nos
Unit
BFP Changeover
2008-09
2009-10
-
8/10/2019 REL EMSModifiedl
42/47
confidential42
Predictive Maintenance
30
23
15
18
0
5
10
15
20
25
30
35
Unit 1 Unit 2
Nos
Unit no
Mill changeover
2008-09
2009-10
-
8/10/2019 REL EMSModifiedl
43/47
confidential43
Predictive Maintenance
0.428
0.648
0.047
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
2007-08 2008-09 2009-10
MUnits
Year
Generation Loss due to Mill Changeover
Gen loss
-
8/10/2019 REL EMSModifiedl
44/47
confidential44
Multi Function Meter
Make : M/s. Conzerv Limited
Model : EM 6400
Measurement parameters : All electrical parameters
Accuracy class : 1.0 class
Auxiliary power supply : 44-300V AC/DC
Display : 3 lines,4 digits LED
Dimensions : 92 X 92 mm
-
8/10/2019 REL EMSModifiedl
45/47
confidential45
Software
Make : Conzerve Limited
Data cable : EIA Industrial RS-485 cable, 22 AWG (7x30) stranded tinned
copper. Twisted pairs. Overall standard tinned copper drain wire.
Converter kit : 2W/4W operation Half Duplex ,Data range 064Kbps,
Communication speed for distance upto 4000 ft 64Kbps,Termination resistor can be enabled/disabled, Surge
suppression & Fuse protection provided, Optical isolation
as protection from ground loops
Data repeater : 05 Nos.
PC for EMS : 02 Nos
-
8/10/2019 REL EMSModifiedl
46/47
confidential46
No. of meters installed
Meters installed on HT feeders : 99
Meters installed on LT feeders : 36
Meters installed on lighting feeders in plant area : 19
Meters installed in colony : 7
-
8/10/2019 REL EMSModifiedl
47/47
Benefits
Availability of online monitoring of all electrical and process parameters of
critical auxiliary at single point which is very useful in Energy audit.
Elimination of human error in measurement due to real time energy management.
Measurable outputs in terms of area wise, equipment wise energy consumption
and aux power measurement is possible.
Compares and identifies the efficient processes & equipment which will be
helpful in taking important operational and maintenance decisions.
Report generation and archiving is possible.
Different type of reports like daily, monthly, quarterly or yearly can be generated
automatically.