sb-dn-sec250k security module sb-dn-sec250k can manage 8 independent zones’ arming and alarm. hdl...
Post on 14-Jan-2016
237 Views
Preview:
TRANSCRIPT
SB-DN-SEC250K
security module SB-DN-SEC250K can manage 8 independent zones’ arming and alarm.
HDL -BUS
Addressing button
SB-DN-SEC250K Function setting
Detected?
Sensor start detecting
Buzzer running
Run defend(Siren/ SMS/
AutoDail)
Arm?
Disarmed?
Trespasser has left?
Arm/disarm:Enable/disable security function
Buzzer:To urge the owner/trespasser to disarm/leave
Siren:Alarm
(check more detailed doc for workflow ftp://59.41.255.150/documents/miscellaneous/)
Work flow
SB-DN-SEC250K
Setup steps:1.Check firmware versions of sensors and security module. (A video has been made to attach to this PPT. ftp://59.41.255.150/softwares/HDL%20tutorial%20video/module%20tutorial%20video/12.%20security%20module/)
2.Enable the security function of sensors.3.Register the sensors in security module and refresh, see if the security module can get the status of sensors. (also you can set some indicators in security module, so that when arming fails you would know which sensor channel fails - e.g., window1
still open, door2 still open…)4.Choose DLP as a user interface to arm and disarm. (better to use DLP because DLP has password for every page – long press the first button and fourth button at the same
time to jump to setting page, ftp://59.41.255.150/documents/miscellaneous/)5.Register the panel in security module6.Find a SD card (<8GB, recommend to use Kingston card) and format it as FAT32, create a folder and name it “special”, put some voice files (.mp3 and sort
them with a header “001”, “002”, “003”… - check the video).7.Check the universal switch list of Z-Audio, especially the “208”, “150” (150 is reserved for folder “special”) and “1-149”.8.Fill in targets in security module and have a test. (check the video)9.Check the “security workflow.doc” (ftp://59.41.255.150/documents/miscellaneous/)
SB-DN-SEC250K
Enable security function
Assign this channel of sensor to one area of security module.
Sensor setting
Same settings can be applied to other channels.
SB-DN-SEC250K
Basic information
Security module has built-in battery and so has real time.
Security history
Almighty password:888,888Read history: freeDelete history: password needed.
SB-DN-SEC250K
Enable security function
Enable security function of security module.
SB-DN-SEC250K
Register sensors in logic module
Enable and register the sensorsSet sensor type
Security module should be able to get the status of sensors.
Generally just leave it unchecked. When arming procedure is started, the security module will check the status of sensors and determine if it is clear to arm, if it is not, the indicator will be triggered.
Double click to set the indicator targets
SB-DN-SEC250K
Authorize some devices(generally the user panel) to arm/disarm
SB-DN-SEC250K
Set arm and disarm commands in DLP
“single on”
SB-DN-SEC250K
Check the folder “special” in Z-Audio
SB-DN-SEC250K
Check the universal switch list of Z-Audio, “208”, “150” (reserved for the folder “special”) and “1-149”. Download the list - ftp://59.41.255.150/documents/en_PDF/
SB-DN-SEC250K
Set warning sound targets
Fill in targets according to customer’s requirements. To do that, it is very important to get familiar with the security workflow. (“security workflow.doc” - ftp://59.41.255.150/documents/miscellaneous/) Below is an example of setting warning sound for “ENTER BUZZER ON”