smartpack new

Post on 02-Jan-2016

87 Views

Category:

Documents

1 Downloads

Preview:

Click to see full reader

DESCRIPTION

Power

TRANSCRIPT

June 2006

2

Eltek

Scaleable and flexible control module for the entire Eltek product range

3

Eltek

Small but powerfulSmall but powerful

44mm

109 mm

144 mm

< 300g

4

Eltek

”Traffic Light”LEDs

Front PanelStandardFront PanelStandard

2x16 character display

3 button Keypad

USB Port

CAN Bus IDDIP switches

5

Eltek

Rear PanelCAN BusRear PanelCAN Bus

CAN bus

Part No : 242100.110(RoHS compliant)

120 ohm term. required at each end

ID based serial bus communications

Max 8 Smartpack

Max 50 Rectifiers

6

Eltek

Rear PanelBattery MonitoringRear PanelBattery Monitoring

Battery Monitoring

Part No : 242100.110(RoHS compliant)

Con 4 : StandardCon 3 : Extended

• Symmetry measurement

• 8 strings mid point or2 strings 12V block

• Temp sense

7

Eltek

Rear PanelInternal SystemRear PanelInternal System

Internal System

Part No : 242100.110(RoHS compliant)

System measurements

Unit Power

2xLVD control (Latched)

Battery fuse fail

8

Eltek

Rear PanelAlarm I/ORear PanelAlarm I/O

Alarm I/O

Part No : 242100.110(RoHS compliant)

Con 1 (standard):-

2 + 2 relay input / output

Con 2 (extended):-

4 + 4 relay input / output

9

Eltek

RS-232 OptionRS-232 Option

RS-232 mounted

Part No : 242100.111(RoHS compliant)

•Enables connection of Standalone Webpower or modem

•Rear position : Replaces extended Battery symmetry card

Part No : 242100.112(RoHS compliant)

10

Eltek

1. Remove 4 chassis screws2. Remove top D-Sub fixings (CON 2 & 3).3. Lift top cover from the front.(Re-assemble in reverse order)

Opening the SmartpackOpening the Smartpack

11

Eltek

Rear PanelEmbedded WebpowerRear PanelEmbedded Webpower

Embedded

WebPower

Part No : 242100.113(RoHS compliant)

Ethernet interface of remote monitoring of SmartpackIs possible to “tunnel” Powersuite remotely also.

12

Eltek

FunctionalityFunctionality

Battery monitoring and testing

Temperature compensated charging

Battery lifetime indication

Alarm/event log (1000) with time and date

And much more ….

13

Eltek

ScalabilityScalability

Smartpack MasterSmartpack Slave n

System functionalityVoltage input 1

Symmetry inputs 8 (2x4x12V)

Current inputs 2

Temperature inputs 2

General purpose inputs 6

Load fuse input 1

Batt fuse input 2

Relay outputs 6

Contactor control 2+

System functionalityVoltage inputs 2

Symmetry inputs 16 (4x4x12V)

Current inputs 4

Temperature inputs 4

General purpose inputs 12

Load fuse input 2

Batt fuse input 4

Relay outputs 12

Contactor control 4+

System functionality with 8 modulesVoltage inputs 8

Symmetry inputs 64 (16x4x12V)

Current inputs 2x8

Temperature inputs 2x8

General purpose inputs 6x8

Load fuse input 1x8

Batt fuse input 2x8

Relay outputs 6x8

Contactor control 2+x8

Smartpack Slave 1

CAN/Power bus

14

Eltek

ConnectivityBatteryConnectivityBattery

CON3 & CON4 – Battery Connections

Temp SenseCable

Pin Function

1 Symmetry I/P 1

2 Symmetry I/P 2

3 Symmetry I/P 3

4 Symmetry I/P 4

5 Symmetry I/P 5

6 Symmetry I/P 6

7 Symmetry I/P 7

8 Symmetry I/P 8

9-10 Con 3 : Temp sense 2Con 4 : Temp sense 1

11 - 14 Con 3 – 2nd batt current, batt fuseCon 4 : Not used

15

Eltek

Symmetry measurement options

ConnectivitySymmetryConnectivitySymmetry

16

Eltek

ConnectivitySystemConnectivitySystem

CON5 – System ConnectionsPin Function

1 Positive Input

2 Negative Input

3 Batt Current +ve

4 Batt Current -ve

5 Batt Fuse +ve

6 Batt Fuse -ve

7 Load Fuse Fail

8 LVD1 Active

9 LVD1 Common

10 LVD2 Active

11 LVD2 CommonSystem Connection Card. Art 200625

17

Eltek

ConnectivitySystemConnectivitySystem

System card configuration

JP1-48v system = 1-2 +24v system = 2-3

JP2-48v system = ‘Neg’+24v system = ‘Pos’

18

Eltek

Connectivity Latched ContactorsConnectivity Latched Contactors

A latching contactor changes state only when a reversed pulse voltage is applied to the coil.

Protection Diode

19

Eltek

ConnectivityExternal Alarm I/OConnectivityExternal Alarm I/O

CON1 & CON2 – I/O Connections

Pin Function

1 - 2 Alarm input 1 ( + / -)

3 – 4 Alarm input 2 ( + / -)

5 - 7 Alarm output 1 ( NO /C / NC)

8 - 10 Alarm output 2 ( NO /C / NC)

1 - 2 Alarm input 3 ( + / -)

3 - 4 Alarm input 4 ( + / -)

5 - 6 Alarm input 5 ( + / -)

7 - 8 Alarm input 6 ( + / -)

9 - 11 Alarm output 3 ( NO /C / NC)

12 - 14 Alarm output 4 ( NO /C / NC)

15 - 17 Alarm output 5 ( NO /C / NC)

18 - 20 Alarm output 6 ( NO /C / NC)Alarm Output & Input Card

Art 105954

20

Eltek

Smartpack Extended Master Smartnode

CAN/Power bus Customer equipment

Convert PCOMM to Customer specific Protocol

Part no: 242100.200

Communicating with Smartpack on CAN bus

RS232 and RS485 serial interface as standard

SmartnodeSmartnode

Customer bus (RS 485)

Smartpack has only PCOMM protocol

21

Eltek

PowerSuitePowerSuite

Explorer oriented easy to use PC SW

USB gives simple access.

Wide functionality with clear graphic presentation.

22

Eltek

PowerSuitePowerSuite

Live Demo

29

Eltek

End of PresentationEnd of Presentation

Let’s us know if you found this presentation useful or would like more information.

Eltek values your feedback.

Thank you

mahmood.sheikh@eltekenergy.com