SITE ADDRESS:

THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................

OWNER ...............................DATE................................

BUILDER ...............................DATE................................

DATE: 19/01/2021SCALE: 1:100, 1:1

JOB N°:REVISION N°:

VARIATIONS:

04

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of 11

2008005

GROUND FLOOR PLAN (A2)

02

REV: DESCRIPTION: INT: DATE: ADENEY

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT: SECRET MYSTERY-62-G

BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

Copy

right

2011

©

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

AREASNameHOUSE - GROUNDHOUSE - UPPERGARAGE/STOREALFRESCOPORCH

Area172.78765.39840.95719.29211.210309.644 m²

Perimeter64.56033.33025.96019.38015.600

SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3

INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2040H (25C) U.N.O.

BUILD METHOD: TFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Timber Truss Flooring System UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System

CL @ 31c THRU'OUTALL UNLESS OTHERWISE NOTED

BRICKLAYER NOTE:RUN KITCHEN & SCULLERY BENCHTOP UNDER WINDOW FRAME.

CUT BWK DOWN TO SUIT BENCHTOP SELECTION.

RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF

FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT

ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &

LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.

TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -

BUILDING CODE OF AUSTRALIA AND AS3660.1:2014 THROUGHTHE USE OF TERMITE RESISTANT MATERIALS FOR ALL

PRIMARY BUILDING ELEMENTS, AS FOLLOWS:*CONCRETE SLAB IN ACCORDANCE WITH AS2870 & AS3600

*MASONARY IN ACCORDANCE WITH AS3700 *PRESERVATIVETREATED TIMBER IN ACCORDANCE WITH AS1604 AND

APPENDIX D OF AS3660.1:2014

FIRE PROTECTION

RAKING BULKHEAD

SQUARE BULKHEAD

BOX GUTTER

RECESSED CEILING

SD

SD

17x910 A

8x2

310

FO

BSTO

UG

HEN

ED 8

x241

0 F

28x

2410

28x3610 SD

28x

2410

28x

1010

28x

1010

7x2

410

DBL

GLA

ZED

5x3

010

F

28x

2410

REMOTE CONTROLSECTIONAL DOOR

820MF 820

MF

2x7

2018

0° H

ING

ES1s

t

2143

x200

0D

HO

820

2143x920DHO

820

820

3x F

ULL H

T. S

LIDER

S(S

OFFI

T OV

ER)

28x

1610

SD

13x

610

82010

20 AF

4x8

10 F

4030 x 3640

3530 x 3570

4490 x 4410

6430 x 5700

6890 x 2800

3360 x 2080

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

MH

INT D.P

D.P

D.P

8,7905,8901,0001,900

3905,0104901,000400

910590

32,59

06,0

905,6

107,8

9010

,200

2,800

6,090

2,800

2,410

400

890

2,410

990

3,010

590

300

2,410

890

1,010

3,490

1,010

1,090

2,800

8,7908005006,890600

8005001,6903,6101,590600

32,59

050

01,4

005,9

003,6

905,0

107,5

905,7

002,8

00

500

1,400

4,590

1,080

230

2,490

810

390

610

2,490

1,610

300

390

2,410

1,490

2,310

990

1,500

2,410

1,790

2,800

930 19

01,1

1029

01,1

1029

01,1

1029

01,1

1050

090

901001,110290

1,0202901,200290

1,300

370930

420

800

700

850

2,000

850

150

90

50

600

730

1,350

6,000

1,071

1,571

1,671

200

1,000

1,500

3251,190325

500

3,390

500

1,000

3,700

1,000

8004,830800

771

3,000

500

901,3

0030

091

029

091

029

091

050

090

500

140

6,367

6,926

15,013

15,306

1,07165 65

1,500

670 1,000

1,690

1

4

EXTENT OFRENDER COLOUR 1

SHOWN DASHED

EXTENT OFUF CANTILEVERSHOWN DASHED

EXTENT OFUPPER FLOOR

SHOWN DASHED

TOP OF POSTFTGS. @ -3c

EXTENT OFRECESSED CL

SHOWN DASHED

EXTENT OFRENDER COLOUR 2

SHOWN DOTTED

UPSTAND WALL@ 33c

TOP OF PIERFTG. @ -3c

T-BAR @ 25c

GARAGE28c CL PLASTERBOARD

GRANO @ -1c2nd FACE BRICK

WORK INTERNALLY

STOR

E

2x S

HELF

& R

AIL

BANK OF 4DRAWERS

3x BANK OF3 DRAWERS

FLUMEDINT/ R/HOOD

GAS HP

2xWO

POTDRAWER

350d

O/H

CPBD

S35

0d O

/HCP

BDS DW

RECDWTAP VO

IDOV

ERHA

NG

300d

O'H

EAD

CPBD

SFR RE

C

UNDE

RMOU

NTSI

NK &

MIX

ERELEC/PLUMBPRELAY

PTY.

4x S

HELV

ES

THEATRE

STUDY

MASTER SUITE

MEALS

FAMILY

ALFRESCO

KITCHEN

ENSUITETILED

WIR

4x SHELVES

WIL

TILED

L'DRYTILED

WMREC

B'TOPONLY

HOBL

ESS

2000HTILEDWALL

31c CLTHROUGHOUT

PDRTILED

CAVITYCLOSER

CAV.CLOSER

LINING TOU/S OFSTAIRS

STORE TIMBERSTAIRS

1050H BALUSTRADEOVER RAKED WALL

RAKED WALLUNDERSTAIRS

FFL = 00cCL = 31c

PORCH28c CL

P'BOARDPAVED @ -1c

T-BAR @ 25c

T-BA

R @

28c

BOUN

DARY

WAL

L @

29c w

/- SQ

UARE

LINE

GUT

TER

TO B

E SE

TBAC

K 10

0mm

FRO

M BO

UNDA

RY

PHYS

ICAL

TER

MITE

BAR

RIER

&FI

RE S

EPAR

ATIO

N RE

QUIR

ED

STORMWATERPRELAY

UNDER SLAB

EXTENT OFRENDER

COLOUR 1

EXTENT OFRENDER

COLOUR 1EXTENT OF

RENDERCOLOUR 2

EXTENT OFRENDER

COLOUR 2

OVER

ALL

WW

WW

WW

31c CL PLASTERBOARDPAVED @ -1c 28

c EAV

ES

28c E

AVES

LVLLVL

LVL

LVL

T-BAR OVER

OVERALL

SD

D

OVER

ALL

DW

WSD

WW

W

OVERALL

GARAGE OPENINGW

LOCATION OFFUTURE PCD

COMBM/BOX

INST.GASHWU

BOUN

DARY

LINE

BOUN

DARY

LINE

BOUNDARY LINE

STAIR INFORISER HEIGHT = 181.9TREAD WIDTH = 250

BOX GUTTEROVER

SPANDREL28c - 31c

550x550

ENTRY

31c CL

31c C

L

31c CL

EXTENT OFRECESSED CL

SHOWN DASHED

34c R

ECES

SED

CL

34c RECESSED CL

31c CL

31c C

L

31c C

LSC

LRY

FRREC600w 28c SQ.

BULKHEAD

600w 28c SQ.BULKHEAD

1900HTILEDWALL

BR

1050HHANDRAIL

SHELF& RAIL

SHELF& RAIL

28c EAVES

PLUMB DUCTw/- ACCESS PANEL

SILL @ 3cHEAD @ 7c

T.O.F.@ -3c

T.O.F. @ -3c

SKYLIGHTPOSITION

TBC

31c C

L

TRAN

SLUC

ENT

GLAZ

ING

REVERSE CYCLEA/C UNIT

900L x 500W x 50HCONCRETE SLAB

3

SHR

1 2 3 4 5 6 7 8

9

UP

5900 x 5810

1900 x 5900

850

2,000

850

RAKI

NG B

'HEA

D

2/ 550mm x700mm

2

TOTAL

SITE ADDRESS:

THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :OWNER ................................DATE...............................

OWNER ...............................DATE................................

BUILDER ...............................DATE................................

DATE: 19/01/2021SCALE: 1:100, 1:1

JOB N°:REVISION N°:

VARIATIONS:

05

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of 11

2008005

UPPER FLOOR PLAN (A2)

02

REV: DESCRIPTION: INT: DATE: ADENEY

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT: SECRET MYSTERY-62-G

BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

Copy

right

2011

©

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

AREASNameHOUSE - GROUNDHOUSE - UPPERGARAGE/STOREALFRESCOPORCH

Area172.78765.39840.95719.29211.210309.644 m²

Perimeter64.56033.33025.96019.38015.600

UPPER FLOOR CONSTRUCTION NOTEALLOW EXTRA STUDWORK FOR: - WC ROLL HOLDER @ 750mm - TOWEL RAIL @ 1000mm - TOWEL RING @ 1200mm - TOILET @ 750mm

UPPER FLOOR GLAZINGUPPER FLOOR WINDOWS TO COMPLY WITH BCA 3.9.2.5

UPPER FLOOR HEIGHTSFFL =3092mmCL = 5527mmHEIGHT O/A= 2435mm (28c)

CL @ 28c THRU'OUTALL UNLESS OTHERWISE NOTED

SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3

INTERNAL DOORS NOTE:ALL INTERNAL DOORS TO BE 2040H (25C) U.N.O.

BUILD METHOD: TFTW GROUND FLOOR: Double Brick, Slab on Ground UPPER FLOOR SLAB: Timber Truss Flooring System UPPER FLOOR WALLS: Timber Wall, 100mm Thermal Clad ROOF TYPE: Colorbond INTERNAL PLASTER: Premium Wall System

RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF

FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT

ELEVATION, PORCH WALL, PIER & UPPER FLOOR FRONTELEVATION OF BED 2.

EXTENT OF WEATHERBOARD CLADDING TO PORTIONS OF BED 2FRONT & RHS WALLS AS SHOWN ON PLANS.

TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -

BUILDING CODE OF AUSTRALIA AND AS3660.1:2014 THROUGHTHE USE OF TERMITE RESISTANT MATERIALS FOR ALL

PRIMARY BUILDING ELEMENTS, AS FOLLOWS:*CONCRETE SLAB IN ACCORDANCE WITH AS2870 & AS3600

*MASONARY IN ACCORDANCE WITH AS3700 *PRESERVATIVETREATED TIMBER IN ACCORDANCE WITH AS1604 AND

APPENDIX D OF AS3660.1:2014

BOX GUTTER

SD

514x

2410

857x

1810

F

1972x2410 A

1972x1210 A

772x2010

820

8202x FULL HT. SLIDERS(SOFFIT OVER)

720

4.5m CONE OF VISION 4.5m CONE OF VISION

3600 x 3130

3600 x 3520

3380 x 4090

4.5m CONE OF VISION

MH

D.PD.P

D.PD.P

1

4

3

7,4503,9052,0101,535

9,215

1,345

7,870

9,215

4,075

2,410

590

1,810

330

7,3655,0102,355

7002,4102,3851,210660

21,42

0

1,340

40

600

500

2,5001,100

840

500

1,400

190

400

EXTENT OFNOM. CLADDINGSHOWN DOTTED

100mm THERMAL CLADDINGTO OUTSIDE OF STUD

(EXTENT SHOWN DASHED

BATHTIMBER STAIRS

1050H BALUSTRADE

TILED

HOBLESS BATHLINEN

ROBE

ACTIVITY

BED 3

BED 2

33cUPSTAND

2x FULL HT. SLIDERS(SOFFIT OVER)

ROOFBELOW

ROOFBELOW

BOUN

DARY

LINE

BOUN

DARY

LINE

BOUNDARY LINE

550x550 STAIR INFORISER HEIGHT = 181.5TREAD WIDTH = 250

STAIR INFORISER HEIGHT = 181.9TREAD WIDTH = 250

BOX GUTTER

EXTENT OFCLADDING

OVERALL

WW

OVER

ALL

WW

OVER

ALL

OVERALL

W

1050H HANDRAIL

1050HHANDRAIL

HOB MTD.SHR SCREEN

EXTENT OFCLADDING

4x SHELVES

AC

SKYLIGHTPOSITION

TBC

WIR

1 2 3 4 5 6 7 8

9

1011121314151617DN

2

SHR

2/ 550mm x700mm

TOTAL

JOB REF: 2008005R

101 Residential Pty Ltd 9208 9100 approvals@101residential.com.au

DEVELOPMENT APPLICATIONSUPPORTING LETTER

LOT 705 (#56B) KENNEDY STREET, ALFRED COVE

SITE ADDRESS:OWNER ................................DATE...............................

OWNER ...............................DATE................................

BUILDER ...............................DATE................................

DATE: 19/01/2021SCALE: 1:200, 1:100

JOB N°:REVISION N°:

VARIATIONS:

03

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of 11

2008005

SITE PLAN

02

REV: DESCRIPTION: INT: DATE: ADENEY

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT: SECRET MYSTERY-62-G

BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

Copy

right

2011

©

THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

SITE CLASSIFICATION : AFOOTING DETAIL : R.T. ENGS.WIND CATEGORY : N1CORROSION CLASS : R3

- LOCATION OF SERVICES

STORMWATER NOTE:STORMWATER DISPOSAL TO ENGINEER'S

DETAILS.

CONCRETE NOTE:SET SHOWER RECESS DOWN 50mm (25mm

BELOW 25mm SET DOWN) & FIT REFLUXVALVE. MAINTAIN REQUIRED SLAB THICKNESS

TO ENGINEERS REQUIREMENTS

TERMITE TREATMENT NOTE:TERMITE TREATMENT WILL BE CARRIED OUT INACCORDANCE WITH PART 3.1.3.2 OF THE NCC -

BUILDING CODE OF AUSTRALIA ANDAS3660.1:2014 THROUGH THE USE OF TERMITE

RESISTANT MATERIALS FOR ALL PRIMARYBUILDING ELEMENTS, AS FOLLOWS:

*CONCRETE SLAB IN ACCORDANCE WITHAS2870 & AS3600

*MASONARY IN ACCORDANCE WITH AS3700*PRESERVATIVE TREATED TIMBER IN

ACCORDANCE WITH AS1604 AND APPENDIX DOF AS3660.1:2014

Proposed Panel+ Post Retaining.

Panel & PostRetaining (required)

ELECTRICAL NOTE:3 - PHASE POWER

PRELAY NOTE:PLUMBING & ELECTRICAL PRELAY REQUIRED FOR

ISLAND CUPBOARD REFER TO FLOOR PLAN

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

SITE COVERAGEZONED R20% ALLOWED 50%SITE AREA 544.00m2

SITE COV. AREA 219.05m2

OPEN SPACE =59.7%

SW1.2 x 0.9

SW1.2 x 0.9

SW1.2 x 1.2

SW1.2 x 1.2

Soak Well TypeNo.SW 1200x90022.0 m3SW 1200x120022.7 m3

Total Capacity4.8 m3Roof Area GF203.9 m2Paved Area27.8 m2Roof Area UF80.1 m2Total Area311.8 m2Capacity Required (Area x 0.0125)3.9 m3Extra Capacity Provided0.9 m3

NOTE: ALL DOWNPIPES CONNECTEDTO SOAKWELLS WITH PVC

STORMWATER PIPE

INT D.P

D.P

D.P

6,000

1,071

1,801

1,6711,500

6,000

6,090

5,610

7,890

10,20

018

,183

1,071 7,490 500 1,000

6,624

7,800

3,690

5,010

7,590

5,700

17,75

6

1,071 1,900 5,590 500 1,000

1,000

771

200

6,367

6,928

15,306

15,013

1,050

1,500

EXTENT OFUF CANTILEVERSHOWN DASHED

0.003 mLOT MISCLOSE

53.97

9 3 ° 3 3 '0 "

10.08

8 6 ° 2 7 '0 "54

.17

9 2 ° 2 6 '0 "

10.07

87°34'

0"

10 .2810 .25

10 .3010 .26

10 .3710 .35

10 .38 10 .33

10 .6010 .68

10 .85 10 .84

10 .93

10 .84

10 .8610 .81

10 .9110 .9310 .96

10 .961 0 .9 21 0 .8 8

10.7

510

.74

10.4

610

.34

10.1

910

.05

10.1

8

1 1 .9 71 1 .0 7

10 .14

10 .12

10 .0910 .07

10 .07

9 .959 .9 7

9 .9 1

10 .1110 .20

1 0 .0 39 .9 5

1 0 .0 7

VACANT

DUG TO LEVEL10.09 ON LOT(SAND/ POSS

L/STONE)

Comm

s Con

n.

Sewe

r I.O

.

PEG FNDNUMB

C

10.7

110

.54

10.3

410

.20

10.0

3

TF[ ]TF[ ]

1 0 .0 6TF[ ]

Brick & Galv.On Slab

Brick & Galv.On Slab(Clear)

Sewer M/H

Approx. 19.7m

(10.02)>>> >>>

Ref Nail At Base Of KerbAssumed Datum 10.00 m

Verge TreeØ 0.60mHt 7.0m

Step

ped C

olorb

ond

Fenc

e (Go

od C

ond.)

Step

ped C

olorb

ond

Fenc

e (Go

od C

ond.)

Sewer JunctionIn: 3.5 Up: 1.4Inv: 8.5 Depth: 0.2NOTE: UP

BEWARE:Shallow sewer junction.Check With Water CorpBUILDER and PLUMBERcheck GRADE.

10.0

10.7

5

1 0 .9 21 0 .9 21 0 .9 2

1 0 .5 8

PAINT MARK FOUND ONFENCE OFFSET 0.12mPAINT MARK FOUND ON

FENCE OFFSET 0.12m

.

1:200cJ/N: DATE: DRAWN:SCALE:

Licensed Surveyors

87-89 Guthrie Street, Osborne Park, Western AustraliaTelephone: (08) 9446 7361 Facsimile: (08) 9445 2998

Email : perth@cottage.com.au Website: www.cottage.com.au

Lot boundaries drawn on survey arebased on landgate plan only. Survey does notinclude title search and as such may not showeasements or other interests not shown on plan.Title should be checked to verify all lot detailsand for any easements or other interests whichmay affect building on the property.

Survey does not include verification of cadastralboundaries. All features and levels shown arebased on orientation to existing pegs and fencesonly which may not be on correct cadastral alignment.Any designs based or dependent on the location ofexisting features should have those features'location verified in relation to the true boundary.

Survey shows visible features only and will notshow locations of underground pipes or conduitsfor internal or mains services. Verification ofthe location of all internal and mains servicesshould be confirmed prior to finalisation of anydesign work.

Cottage & Engineering surveys accept noresponsibility for any physical on site changes tothe parcel or portion of the parcel of land shownon this survey including any adjoining neighbourslevels and features that have occurred after thedate on this survey. All Sewer details plottedfrom information supplied by Water Corporation.

DISCLAIMER:

DISCLAIMER:

DISCLAIMER:

DISCLAIMER:

SEC DomePower PolePhone Pits

LEGE

ND T C

TP 10.00TWTRTF

[[[[

10.0010.0010.00

]]]]

Top Pillar/PostTop WallTop RetainingTop Fence

W Water Conn.

K e n n e d y S t r e e tBitumen

OLDAREA

Scale 1:200

0 2 4 6 8

W

S

E

N

SOIL DESCRIPTIONSandMedium Grass Cover

477477 21 Aug 20 J.Genovese

Builder : 101 Residential Pty LtdCLIENT : ADENEYLOT 705 #56B Kennedy Street, Alfred Cove

D.Plan418486

ConcreteNon-Mount

Non-MountNil

Brick PavedCrossover

Brick PavedDriveway

Brick PavedDriveway

OverhangingTree

Galv. Shed

Galv. Shed

GarageUMR

Poss

ible P

arap

et W

all

Approx. F/L10.55

Colorbond Fence(Good Cond.)

Appr

ox. F

ootin

gLe

vel 1

0.45

10.5

PEGGONE

Slope

LOCATION OFFUTURE PCD

COMBM/BOX

INST.GASHWU

ELEC/PLUMBPRELAY

DW TAP

PROPOSEDRESIDENCEFFL 10.475SPL 10.390

ALFRESCOGRANO @ -1c

PORCHPAVED @ -1c GARAGE

GRANO @ -1c

STOR

E

SETBACK

SETBACK

SETBACK

SETBACK

SETBACK

SETBACK

SETBACK

SETBACK

SETBACK

1m PATH

DRIVEWAY SETB

ACK

CROSSOVERTO COUNCIL'S

SPECIFICATIONS

BOUNDARY WALL @ 29cw/- SQUARELINE GUTTERTO BE SETBACK 200mm

FROM BOUNDARYPHYSICAL TERMITE BARRIER &FIRE SEPARATION REQUIRED

STORMWATERPRELAY

UNDER SLAB

SETBACK

SETBACK

T.O.F.@ -3c

T.O.F.@ -3c

SETBACK

SETBACK

REVERSE CYCLEA/C UNIT

900L x 500W x 50HCONCRETE SLAB

SKYLIGHTPOSITION

TBC

T.O.R. @ 10.580

T.O.R. @ 10.580

T.O.R. @ 10.580

B.O.R. @ 10.460

B.O.R. @ 10.050B.O.R. @ 10.390

2/ 550mm x 700mm

SITE ADDRESS:DATE: 19/01/2021SCALE: 1:100

JOB N°:REVISION N°:

VARIATIONS:

06

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of

200800502

REV: DESCRIPTION: INT: DATE:

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT:

ELEVATIONS 01ADENEY

SECRET MYSTERY-62-G

11

T H I S I S O N E O F T H E D R A W I N G SR E F E R E D T O I N T H E C O N T R A C T :O W N E R ................................DATE...............................

O W N E R ...............................DATE................................

B U I L D E R ...............................DATE................................B U I L D E R S R E G I S T R A T I O N N ° 1 3 5 2 19 S A N G I O R G I O C O U R TO S B O R N E P A R K W A 6 0 1 7P h o n e (0 8 ) 9 2 0 8 9 1 0 0 F a x (0 8 ) 9 2 0 8 9 1 0 2

Copy

right

2011

©

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

CL 2692 (2692mm)

CL 5527 (5527mm)

2,692

400

2,435

TOP OF PIERFTG. @ -3c

COLORBOND GUTTERS,FASCIA AND DOWNPIPES

25° PITCH COLORBOND ROOF

AUTO SECTIONAL DOOR

T-BAR @ 25c

NOMINATEDCLADDING

T-BAR @25cBLADE WALL

REND

ER C

OLOU

R 2

PIER

RENDERCOLOUR 1 BO

UNDA

RY LI

NE

THERMAL CLADDINGw/- RENDERCOLOUR 1

NGL

CORNERMOULDING

WINDOW MOULDINGSTO SUIT NOMINATED

CLADDING THROUGHOUT

FL 3092 (3092mm)

FL 0 (0c)

5309

3337

5309 5309 5309

28c

33c

11c

25c 2400

3337

T.O.F. @ -3c

25c

4709 4709

CL 2692 (2692mm)

CL 5527 (5527mm)

2,692

400

2,435

PROPOSED RETAINING WALL

TOP OF PIERFTG. @ -3c

TOP OF POSTFTG. @ -3c

PROPOSED SILLS 10mmRECESSED

FACE BRICK

NOMINATEDCLADDING

THERMAL CLADDING w/-RENDER COLOUR 1

ENTRYDOOR

TRANSLUCENTGLAZING

T-BAR @ 28c

PIER

RENDERCOLOUR 2

TOUGHENEDOBS

INST.GAS HWU

PROPOSED

EG

COMBM/BOXLOCATION OF

FUTURE PCD

NGL

CORNERMOULDING

FL 3092 (3092mm)

FL 0 (0c)T.O.R. @ 10.580T.O.R. @ 10.580

2400 28c 24c

28c 28c

0c

19c 11c

19c 11c

5309 5309

28c

10c

0c

28c 28c

0c

14c

7c 6cT.O.F. @ -3c

15c

RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF

FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT

ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &

LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.

1 ELEVATION1:100

2 ELEVATION1:100

SITE ADDRESS:DATE: 19/01/2021SCALE: 1:100

JOB N°:REVISION N°:

VARIATIONS:

07

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of

200800502

REV: DESCRIPTION: INT: DATE:

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT:

ELEVATIONS 02ADENEY

SECRET MYSTERY-62-G

11

T H I S I S O N E O F T H E D R A W I N G SR E F E R E D T O I N T H E C O N T R A C T :O W N E R ................................DATE...............................

O W N E R ...............................DATE................................

B U I L D E R ...............................DATE................................B U I L D E R S R E G I S T R A T I O N N ° 1 3 5 2 19 S A N G I O R G I O C O U R TO S B O R N E P A R K W A 6 0 1 7P h o n e (0 8 ) 9 2 0 8 9 1 0 0 F a x (0 8 ) 9 2 0 8 9 1 0 2

Copy

right

2011

©

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

CL 2692 (2692mm)

CL 5527 (5527mm)

2,692

400

2,435

3,455 3,995

1,330

TOP OF POSTFTG. @ -3c

SILLS 10mmRECESSEDFACE BRICK

GARAGEDOOR

BOUN

DARY

LINE

THERMAL CLADDINGw/- RENDER COLOUR 1

NGL

COLORBOND GUTTERS,FASCIA AND DOWNPIPES

25° PITCH COLORBOND ROOF

PROPOSEDPROPOSED

RENDERCOLOUR 2

FL 3092 (3092mm)

FL 0 (0c)

28c

5309 5309

28c

0c

24c 28c

33c

5309

4537

33c

T.O.R. @ 10.580T.O.R. @ 10.580

CL 2692 (2692mm)

CL 5527 (5527mm)

2,692

400

2,435

2,2801,2503,1501,2501,370

66

TOP OF POSTFTG. @ -3c

PROPOSED RETAINING WALL

SILLS 10mmRECESSEDFACE BRICK

SPANDREL28c - 31cMOULDING

THERMAL CLADDING w/-RENDER COLOUR 1

BOUNDARY WALL @ 29c w/-SQUARELINE GUTTER TO BE

SETBACK 200mm FROM BOUNDARYPROPOSED

NGL

NOMINATEDCLADDING

CORNERMOULDING

REVERSECYCLE

A/C UNIT

SKYLIGHTSPOSITION

TBC

FL 3092 (3092mm)

FL 0 (0c)T.O.R. @ 10.580

5309

28c 28c

0c

10c

28c

0c

10c

28c

0c

10c

28c 23c

28c 21c

28c

0c

10c

5309

4452

5309 4795

33c

29c 2400

31c 31c

5309550mm x 700mm

RENDER NOTE:EXTENT OF RENDER COLOUR 1 TO PORCH RHS T-BAR, FRONTOF STUDY, ENTIRE UPPER FLOOR AND RETURN EXCLUDING UF

FRONT & RHS OF BED 2.EXTENT OF RENDER COLOUR 2 TO GROUND FLOOR FRONT

ELEVATION, PORCH WALL & PIER.EXTENT OF NOMNATED CLADDING TO FRONT ELEVATION, RHS &

LHS RETURN OF BED 2. EXTENT OF RENDER AS PER PLAN.

BRICKLAYER NOTE:RUN KITCHEN & SCULLERY BENCHTOP UNDER WINDOW FRAME.

CUT BWK DOWN TO SUIT BENCHTOP SELECTION.

3 ELEVATION1:100

4 ELEVATION1:100

SITE ADDRESS:OWNER ................................DATE...............................

OWNER ...............................DATE................................

BUILDER ...............................DATE................................

DATE: 19/01/2021SCALE: 1:1, 1:100

JOB N°:REVISION N°:

VARIATIONS:

08

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of 11

2008005

ELECTRICAL PLAN

02

REV: DESCRIPTION: INT: DATE: ADENEY

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT: SECRET MYSTERY-62-G

BUILDERS REGISTRATION N° 135219 SANGIORGIO COURTOSBORNE PARK WA 6017Phone (08) 9208 9100 Fax (08) 9208 9102

Copy

right

2011

©

THIS IS ONE OF THE DRAWINGSREFERED TO IN THE CONTRACT :

/C1S/

/C2S/

/BS/

/C1D/

/C2D/

/BD/

'1 ' CONTRACT: SILVER SET JB 01.10.20 + SVO 1 (ITEMS 1-14) '2 ' VO1 (ITEMS 1-10) & VO2 (ITEMS 1-69) FC/ SR 15.12.20 '3' '4' '5' '6' '7' '8' '9' '10' '11' '12' '13' '14'

NBN PROVISIONAL NOTE

HOUSE TO BE FITTED WITH; - 1x SGPO WITH CONDUIT @ 1400 AFL, - 1x CONDUIT WITH DRAW-WIRE & BLANK PLATE (Cw) @ 1400 AFL FOR FUTURE PHONE/ DATA POINT, - 1x FIBRE COMMUNICATION CONDUIT WITH DRAWWIRE & BLANK PLATE (FC) NBN @ 1400 AFL.

LOCATION OF FUTURE PCD (PREMISESCONNECTION DEVICE) TO BE NOMINATED ON PLANAT PRESTART.TO BE INSTALLED BY NBN PROVIDER.

NOTE:FIBRE COMMUNICATION CONDUIT TO RUN FULLLENGTH FROM (FC) NBN PLATE TO FUTURE PCDLOCATION.

LIGHT SWITCH BOX NOTELIGHT SWITCH BOX TO FIRST FLOOR TO BE 150mm

MINIMUM FROM INTERNAL OPENING

A/C NOTE:LOCATION OF REVERSE CYCLE AIR CONDITIONING

VENTS & ZONING TO BE PLACED BY INSTALLER.

NOTE:3 PHASE POWER REQUIRED.

NOTE:POSITION OF THE FOLLOWING TO BE CONFIRMED

AT PRESTART:- 1x TV POINT- 1x DATA PHOINT- 1x PHONE POINT

GROUND FLOOR ELECTRICAL LEGENDNUM1

1

1

2

1

2

1

Text for legend14w STD Light

AC Control Panel

Data Point

Exhaust Fan Flumed

Phone Point

Smoke Detector

TV Point

Symb14

F

SD

SD

SD

1st

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

D.P

MH

INT D.P

D.P

D.P

LOCATION OFFUTURE PCD

COMBM/BOX

INST.GASHWU

ELEC/PLUMBPRELAY

DW TAP

550x550

GARAGE

STOR

E

THEATRE

STUDY

MASTER SUITE

MEALS

FAMILY

ALFRESCO

ENSUITE

WIR

WIL

L'DRY

PDR

STORE

PORCH

ENTRY

SCLR

Y

FLUMED

FLUM

ED

FLUMEDINT/ R/HOOD

IND HP

KITCHEN1500

REVERSE CYCLEA/C UNIT

900L x 500W x 50HCONCRETE SLAB

SKYLIGHTPOSITION

TBC

SHR

1 2 3 4 5 6 7 8

9

UP

14

F

F

2/ 550mm x700mm

SD

MH

D.PD.P

D.PD.P

550x550

BATH

ACTIVITY

BED 3

BED 2

FLUMED

WIR

1 2 3 4 5 6 7 8

9

1011121314151617DN

SHR F

FIRST FLOOR ELECTRICAL LEGENDNUM1

1

Text for legendExhaust Fan Flumed

Smoke Detector

SymbF

SD

SITE ADDRESS:OWNER ................................DATE...............................

OWNER ...............................DATE................................

BUILDER ...............................DATE................................

DATE: 19/01/2021SCALE: 1:100

JOB N°:REVISION N°:

VARIATIONS:

11

SALES: DRAWN:SH JB ARCHECKED:

SHEET N°: of 11

2008005

PERSPECTIVES

02

REV: DESCRIPTION: INT: DATE: ADENEY

LOT 705 (#56B) KENNEDY ST.ALFRED COVE WA 6150

CLIENT: SECRET MYSTERY-62-G